WorldWideScience

Sample records for negative capillary pressure

  1. A direct method for determining complete positive and negative capillary pressure curves for reservoir rock using the centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Spinler, E.A.; Baldwin, B.A. [Phillips Petroleum Co., Bartlesville, OK (United States)

    1997-08-01

    A method is being developed for direct experimental determination of capillary pressure curves from saturation distributions produced during centrifuging fluids in a rock plug. A free water level is positioned along the length of the plugs to enable simultaneous determination of both positive and negative capillary pressures. Octadecane as the oil phase is solidified by temperature reduction while centrifuging to prevent fluid redistribution upon removal from the centrifuge. The water saturation is then measured via magnetic resonance imaging. The saturation profile within the plug and the calculation of pressures for each point of the saturation profile allows for a complete capillary pressure curve to be determined from one experiment. Centrifuging under oil with a free water level into a 100 percent water saturated plug results in the development of a primary drainage capillary pressure curve. Centrifuging similarly at an initial water saturation in the plug results in the development of an imbibition capillary pressure curve. Examples of these measurements are presented for Berea sandstone and chalk rocks.

  2. Impacts on oil recovery from capillary pressure and capillary heterogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Bognoe, Thomas

    2008-07-01

    The main conclusions drawn from this thesis are; 7 scientific papers are published on a broad variety of subjects, and describes in detail the experiments and research treated in this thesis. Scientific research has been performed, investigating the subjects of capillary pressure and capillary heterogeneities from different angles. This thesis discusses the findings in this study and aims to illustrate the benefits of the results obtained for further development of other experiments, and/or even the industrial benefits in field development. The methods for wettability alteration have developed throughout the work. From producing heterogeneous wettability alterations, the methods have improved to giving both radial and lateral uniform wettability alterations, which also remains unaltered throughout the duration of the experimental work. The alteration of wettability is dependent on initial water saturation, flow rate, aging time and crude oil composition. Capillary pressure and relative permeability curves have been measured for core plugs at different wettabilities using conventional centrifuge methods. The trends observed are mostly consistent with theory. The production mechanisms of strongly and moderately water wet chalk has been investigated. At strongly water wet conditions in fractured chalk; the flow is governed by capillary forces, showing strong impact from the fractures. At moderately water wet conditions, the impact of the fractures are absent, and a dispersed water front is observed during the displacement. The oil recovery is about the same, at the two wettabilities. Fracture crossing mechanisms at the same wettability conditions have been mapped. And the observations are consistent with those of the water floods. During strongly water wet displacement, the fracture crossing is occurring once the inlet core has reached endpoint of spontaneous imbibition. At moderately water wet conditions the fracture crossing is less abrupt, and creation of wetting

  3. Capillarity Induced Negative Pressure of Water Plugs in Nanochannels

    NARCIS (Netherlands)

    Tas, Niels Roelof; Mela, P.; Kramer, Tobias; Berenschot, Johan W.; van den Berg, Albert

    2003-01-01

    We have found evidence that water plugs in hydrophilic nanochannels can be at significant negative pressure due to tensile capillary forces. The negative pressure of water plugs in nanochannels induces bending of the thin channel capping layer, which results in a visible curvature of the liquid

  4. Pulmonary capillary pressure in pulmonary hypertension.

    Science.gov (United States)

    Souza, Rogerio; Amato, Marcelo Britto Passos; Demarzo, Sergio Eduardo; Deheinzelin, Daniel; Barbas, Carmen Silvia Valente; Schettino, Guilherme Paula Pinto; Carvalho, Carlos Roberto Ribeiro

    2005-04-01

    Pulmonary capillary pressure (PCP), together with the time constants of the various vascular compartments, define the dynamics of the pulmonary vascular system. Our objective in the present study was to estimate PCPs and time constants of the vascular system in patients with idiopathic pulmonary arterial hypertension (IPAH), and compare them with these measures in patients with acute respiratory distress syndrome (ARDS). We conducted the study in two groups of patients with pulmonary hypertension: 12 patients with IPAH and 11 with ARDS. Four methods were used to estimate the PCP based on monoexponential and biexponential fitting of pulmonary artery pressure decay curves. PCPs in the IPAH group were considerably greater than those in the ARDS group. The PCPs measured using the four methods also differed significantly, suggesting that each method measures the pressure at a different site in the pulmonary circulation. The time constant for the slow component of the biexponential fit in the IPAH group was significantly longer than that in the ARDS group. The PCP in IPAH patients is greater than normal but methodological limitations related to the occlusion technique may limit interpretation of these data in isolation. Different disease processes may result in different times for arterial emptying, with resulting implications for the methods available for estimating PCP.

  5. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  6. Capillary Pressure-induced Lung Injury: Fact or Fiction?

    African Journals Online (AJOL)

    QuickSilver

    2003-05-07

    May 7, 2003 ... ing severe exercise, thus causing significant capillary hyper- tension. Pulmonary ... sponses evoked by high-pressure stress. To clarify the .... by an increased release of the vasoconstrictor endothelin-1 and thromboxane A2.

  7. Negative pressure pulmonary edema revisited: Pathophysiology and review of management

    Directory of Open Access Journals (Sweden)

    Balu Bhaskar

    2011-01-01

    Full Text Available Negative pressure pulmonary edema (NPPE is a dangerous and potentially fatal condition with a multifactorial pathogenesis. Frequently, NPPE is a manifestation of upper airway obstruction, the large negative intrathoracic pressure generated by forced inspiration against an obstructed airway is thought to be the principal mechanism involved. This negative pressure leads to an increase in pulmonary vascular volume and pulmonary capillary transmural pressure, creating a risk of disruption of the alveolar-capillary membrane. The early detection of the signs of this syndrome is vital to the treatment and to patient outcome. The purpose of this review is to highlight the available literature on NPPE, while probing the pathophysiological mechanisms relevant in both the development of this condition and that involved in its resolution.

  8. Negative-Pressure Pulmonary Edema.

    Science.gov (United States)

    Bhattacharya, Mallar; Kallet, Richard H; Ware, Lorraine B; Matthay, Michael A

    2016-10-01

    Negative-pressure pulmonary edema (NPPE) or postobstructive pulmonary edema is a well-described cause of acute respiratory failure that occurs after intense inspiratory effort against an obstructed airway, usually from upper airway infection, tumor, or laryngospasm. Patients with NPPE generate very negative airway pressures, which augment transvascular fluid filtration and precipitate interstitial and alveolar edema. Pulmonary edema fluid collected from most patients with NPPE has a low protein concentration, suggesting hydrostatic forces as the primary mechanism for the pathogenesis of NPPE. Supportive care should be directed at relieving the upper airway obstruction by endotracheal intubation or cricothyroidotomy, institution of lung-protective positive-pressure ventilation, and diuresis unless the patient is in shock. Resolution of the pulmonary edema is usually rapid, in part because alveolar fluid clearance mechanisms are intact. In this review, we discuss the clinical presentation, pathophysiology, and management of negative-pressure or postobstructive pulmonary edema. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  9. Incisional Negative Pressure Wound Therapy

    DEFF Research Database (Denmark)

    Hyldig, Nana

    the rate of surgical wound infection and wound exudate post-caesarean and that wound infection had a negative impact on quality of life one month after surgery. Alongside the clinical trial, a trial-based cost-effectiveness analysis demonstrated that the treatment is cost-effective in a high......Women with a pre-gestational body mass index (BMI) above 30 kg/m2 giving birth by caesarean section are at high risk of surgical wound infection compared with women with a BMI below 30 kg/m2. Incisional Negative Pressure Wound Therapy (iNPWT) is one strategy to reduce the rate of surgical wound...... a randomised controlled trial in two tertiary and three teaching hospitals in three regions of Denmark, the Happy Belly Study, investigating the effectiveness of iNPWT in a population of obese women after caesarean section. The Happy Belly Study has demonstrated that prophylactic iNPWT significantly reduced...

  10. The unsaturated flow in porous media with dynamic capillary pressure

    Science.gov (United States)

    Milišić, Josipa-Pina

    2018-05-01

    In this paper we consider a degenerate pseudoparabolic equation for the wetting saturation of an unsaturated two-phase flow in porous media with dynamic capillary pressure-saturation relationship where the relaxation parameter depends on the saturation. Following the approach given in [13] the existence of a weak solution is proved using Galerkin approximation and regularization techniques. A priori estimates needed for passing to the limit when the regularization parameter goes to zero are obtained by using appropriate test-functions, motivated by the fact that considered PDE allows a natural generalization of the classical Kullback entropy. Finally, a special care was given in obtaining an estimate of the mixed-derivative term by combining the information from the capillary pressure with the obtained a priori estimates on the saturation.

  11. Phase Envelope Calculations for Reservoir Fluids in the Presence of Capillary Pressure

    DEFF Research Database (Denmark)

    Lemus, Diego; Yan, Wei; Michelsen, Michael L.

    2015-01-01

    the bubble and dew point curves but also other quality lines with vapor fractions between 0 and 1. The algorithm has been used to calculate the phase envelopes of binary, multicomponent and reservoir fluid systems for pore radius from 10 to 50 nm. The presence of capillary pressure changes the saturation...... pressures in the whole phase envelope except at the critical point. The bubble point curve shows a negative change while the dew point curve shows positive and negative changes in the upper dew point branch and the lower dew point branch, respectively. In particular, the cricondentherm is also shifted...

  12. Relationships between fluid pressure and capillary pressure in ...

    African Journals Online (AJOL)

    In this work, the Bower's and Gardner's technique of velocity-to fluid pressure gradient methods were applied on seismic reflection data in order to predict fluid pressure of an X- oil field in Niger Delta Basin. Results show significant deflection common with fluid pressure zones . With average connate water saturation Swc ...

  13. Negative pressure characteristics of an evaporating meniscus at nanoscale

    Directory of Open Access Journals (Sweden)

    Maroo Shalabh

    2011-01-01

    Full Text Available Abstract This study aims at understanding the characteristics of negative liquid pressures at the nanoscale using molecular dynamics simulation. A nano-meniscus is formed by placing liquid argon on a platinum wall between two nano-channels filled with the same liquid. Evaporation is simulated in the meniscus by increasing the temperature of the platinum wall for two different cases. Non-evaporating films are obtained at the center of the meniscus. The liquid film in the non-evaporating and adjacent regions is found to be under high absolute negative pressures. Cavitation cannot occur in these regions as the capillary height is smaller than the critical cavitation radius. Factors which determine the critical film thickness for rupture are discussed. Thus, high negative liquid pressures can be stable at the nanoscale, and utilized to create passive pumping devices as well as significantly enhance heat transfer rates.

  14. Negative Pressure Wound Therapy in Maxillofacial Applications

    Directory of Open Access Journals (Sweden)

    Adam J. Mellott

    2016-09-01

    Full Text Available Negative pressure wound therapy has greatly advanced the field of wound healing for nearly two decades, by providing a robust surgical adjunct technique for accelerating wound closure in acute and chronic wounds. However, the application of negative pressure wound therapy in maxillofacial applications has been relatively under utilized as a result of the physical articulations and contours of the head and neck that make it challenging to obtain an airtight seal for different negative pressure wound therapy systems. Adapting negative pressure wound therapies for maxillofacial applications could yield significant enhancement of wound closure in maxillofacial applications. The current review summarizes the basic science underlying negative pressure wound therapy, as well as specific maxillofacial procedures that could benefit from negative pressure wound therapy.

  15. Negative pressure pulmonary oedema after septoplasty.

    Science.gov (United States)

    García de Hombre, Alina M; Cuffini, Alejandro; Bonadeo, Alejandro

    2013-01-01

    Negative pressure pulmonary oedema (NPPO) is an anaesthetic complication due to acute obstruction of the upper airway, whose main cause is laryngospasm. The pathophysiology involves a strong negative intrapleural pressure during inspiration against a closed glottis, which triggers excessive pressure in the pulmonary microvasculature. Although its diagnosis can be difficult, its recognition helps to minimise morbidity and mortality. This article presents a case of NPPO due to postextubation laryngospasm. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  16. The feasibility and reliability of capillary blood pressure measurements in the fingernail fold

    NARCIS (Netherlands)

    de Graaff, Jurgen C.; Ubbink, Dirk Th; Lagarde, Sjoerd M.; Jacobs, Michael J. H. M.

    2002-01-01

    Capillary blood pressure is an essential parameter in the study of the (patho-)physiology of microvascular perfusion. Currently, capillary pressure measurements in humans are performed using a servo-nulling micropressure system containing an oil-water interface, which suffers some drawbacks. In

  17. Ice nucleation triggered by negative pressure.

    Science.gov (United States)

    Marcolli, Claudia

    2017-11-30

    Homogeneous ice nucleation needs supercooling of more than 35 K to become effective. When pressure is applied to water, the melting and the freezing points both decrease. Conversely, melting and freezing temperatures increase under negative pressure, i.e. when water is stretched. This study presents an extrapolation of homogeneous ice nucleation temperatures from positive to negative pressures as a basis for further exploration of ice nucleation under negative pressure. It predicts that increasing negative pressure at temperatures below about 262 K eventually results in homogeneous ice nucleation while at warmer temperature homogeneous cavitation, i. e. bubble nucleation, dominates. Negative pressure occurs locally and briefly when water is stretched due to mechanical shock, sonic waves, or fragmentation. The occurrence of such transient negative pressure should suffice to trigger homogeneous ice nucleation at large supercooling in the absence of ice-nucleating surfaces. In addition, negative pressure can act together with ice-inducing surfaces to enhance their intrinsic ice nucleation efficiency. Dynamic ice nucleation can be used to improve properties and uniformity of frozen products by applying ultrasonic fields and might also be relevant for the freezing of large drops in rainclouds.

  18. Negative Ions in low pressure discharges

    NARCIS (Netherlands)

    Stoffels - Adamowicz, E.; Stoffels, W.W.; Vender, D.; Haverlag, M.; Kroesen, G.M.W.; Hoog, de F.J.

    1995-01-01

    Several aspects of negative ions in low pressure discharges are treated. The elementary processes, in which negative ions are produced and destroyed, are summarized. The influence of negative ions on plasma operation is analyzed in terms of transport equations. It is shown that diffusion, electric

  19. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    International Nuclear Information System (INIS)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models

  20. Low internal pressure in femtoliter water capillary bridges reduces evaporation rates.

    Science.gov (United States)

    Cho, Kun; Hwang, In Gyu; Kim, Yeseul; Lim, Su Jin; Lim, Jun; Kim, Joon Heon; Gim, Bopil; Weon, Byung Mook

    2016-03-01

    Capillary bridges are usually formed by a small liquid volume in a confined space between two solid surfaces. They can have a lower internal pressure than the surrounding pressure for volumes of the order of femtoliters. Femtoliter capillary bridges with relatively rapid evaporation rates are difficult to explore experimentally. To understand in detail the evaporation of femtoliter capillary bridges, we present a feasible experimental method to directly visualize how water bridges evaporate between a microsphere and a flat substrate in still air using transmission X-ray microscopy. Precise measurements of evaporation rates for water bridges show that lower water pressure than surrounding pressure can significantly decrease evaporation through the suppression of vapor diffusion. This finding provides insight into the evaporation of ultrasmall capillary bridges.

  1. Capillary pressure at irregularly shaped pore throats: Implications for water retention characteristics

    Science.gov (United States)

    Suh, Hyoung Suk; Kang, Dong Hun; Jang, Jaewon; Kim, Kwang Yeom; Yun, Tae Sup

    2017-12-01

    The random shapes of pore throats in geomaterials hinder accurate estimation of capillary pressure, and conventional pore network models that simply use the Young-Laplace equation assuming circular pore throats overestimate the capillary pressure. As a solution to this problem that does not complicate the pore network model or slow its implementation, we propose a new morphological analysis method to correlate the capillary pressure at an irregular pore channel with its cross-sectional geometry using lattice Boltzmann (LB) simulation and Mayer and Stowe-Princen theory. Geometry-based shape factors for pore throats are shown here to correlate strongly with the capillary pressure obtained by LB simulation. Water retention curves obtained by incorporating the morphological calibration into conventional pore network simulation and their correlative scheme agree well with experimental data. The suggested method is relevant to pore-scale processes such as geological CO2 sequestration, methane bubbling from wetlands, and enhanced carbon recovery.

  2. Low internal pressure in femtoliter water capillary bridges reduces evaporation rates

    Science.gov (United States)

    Cho, Kun; Hwang, In Gyu; Kim, Yeseul; Lim, Su Jin; Lim, Jun; Kim, Joon Heon; Gim, Bopil; Weon, Byung Mook

    2016-01-01

    Capillary bridges are usually formed by a small liquid volume in a confined space between two solid surfaces. They can have a lower internal pressure than the surrounding pressure for volumes of the order of femtoliters. Femtoliter capillary bridges with relatively rapid evaporation rates are difficult to explore experimentally. To understand in detail the evaporation of femtoliter capillary bridges, we present a feasible experimental method to directly visualize how water bridges evaporate between a microsphere and a flat substrate in still air using transmission X-ray microscopy. Precise measurements of evaporation rates for water bridges show that lower water pressure than surrounding pressure can significantly decrease evaporation through the suppression of vapor diffusion. This finding provides insight into the evaporation of ultrasmall capillary bridges. PMID:26928329

  3. Variations of Negative Pressure Wound Therapy

    African Journals Online (AJOL)

    a living reaction which serves to eradicate necrotic tissue and suppress bacterial propagation. In order to gain maximum advantages from NPWT, not only the negative pressure environment, but also the selection of the most suitable dressing material will be necessary. Regarding the treatment of diabetic foot ulcers, there.

  4. Direct measurement of the wetting front capillary pressure in a clay brick ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Ioannou, Ioannis [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Hall, Christopher [Centre for Materials Science and Engineering and School of Engineering and Electronics, University of Edinburgh, The King' s Buildings, Edinburgh EH9 3JL (United Kingdom); Wilson, Moira A [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Hoff, William D [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Carter, Margaret A [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom)

    2003-12-21

    The absorption of a liquid into a rectangular bar of an initially dry porous material that is sealed on all surfaces except the inflow face is analysed in terms of Sharp Front theory. Sharp Front models are developed for both complete and incomplete displacement of air ahead of the advancing wetting front. Experiments are described from which a characteristic capillary potential of the material is obtained by measuring the equilibrium pressure of the air displaced and compressed ahead of the advancing wetting front. Results for the absorption of water and n-heptane by a fired clay brick ceramic suggest that this wetting front capillary pressure (or capillary potential) scales approximately with the surface tension and also that the permeability scales inversely with the liquid viscosity. The pressure of the air trapped in the wetted region is found to be the same as the pressure of the displaced air. For this material the wetting front capillary pressure for water at 20 C is 0.113 MPa, equivalent to a hydraulic tension head of 11.5 m and to a Young-Laplace pore diameter of 2.6 {mu}m. The capillary pressure so measured is apparently a fundamental percolation property of the material that can be interpreted as the air pressure at which liquid phase continuity and unsaturated conductivity both vanish. The method described can be applied generally to porous materials.

  5. Direct measurement of the wetting front capillary pressure in a clay brick ceramic

    International Nuclear Information System (INIS)

    Ioannou, Ioannis; Hall, Christopher; Wilson, Moira A; Hoff, William D; Carter, Margaret A

    2003-01-01

    The absorption of a liquid into a rectangular bar of an initially dry porous material that is sealed on all surfaces except the inflow face is analysed in terms of Sharp Front theory. Sharp Front models are developed for both complete and incomplete displacement of air ahead of the advancing wetting front. Experiments are described from which a characteristic capillary potential of the material is obtained by measuring the equilibrium pressure of the air displaced and compressed ahead of the advancing wetting front. Results for the absorption of water and n-heptane by a fired clay brick ceramic suggest that this wetting front capillary pressure (or capillary potential) scales approximately with the surface tension and also that the permeability scales inversely with the liquid viscosity. The pressure of the air trapped in the wetted region is found to be the same as the pressure of the displaced air. For this material the wetting front capillary pressure for water at 20 C is 0.113 MPa, equivalent to a hydraulic tension head of 11.5 m and to a Young-Laplace pore diameter of 2.6 μm. The capillary pressure so measured is apparently a fundamental percolation property of the material that can be interpreted as the air pressure at which liquid phase continuity and unsaturated conductivity both vanish. The method described can be applied generally to porous materials

  6. Direct Printing of Stretchable Elastomers for Highly Sensitive Capillary Pressure Sensors.

    Science.gov (United States)

    Liu, Wenguang; Yan, Chaoyi

    2018-03-28

    We demonstrate the successful fabrication of highly sensitive capillary pressure sensors using an innovative 3D printing method. Unlike conventional capacitive pressure sensors where the capacitance changes were due to the pressure-induced interspace variations between the parallel plate electrodes, in our capillary sensors the capacitance was determined by the extrusion and extraction of liquid medium and consequent changes of dielectric constants. Significant pressure sensitivity advances up to 547.9 KPa -1 were achieved. Moreover, we suggest that our innovative capillary pressure sensors can adopt a wide range of liquid mediums, such as ethanol, deionized water, and their mixtures. The devices also showed stable performances upon repeated pressing cycles. The direct and versatile printing method combined with the significant performance advances are expected to find important applications in future stretchable and wearable electronics.

  7. Minimized Capillary End Effect During CO2 Displacement in 2-D Micromodel by Manipulating Capillary Pressure at the Outlet Boundary in Lattice Boltzmann Method

    Science.gov (United States)

    Kang, Dong Hun; Yun, Tae Sup

    2018-02-01

    We propose a new outflow boundary condition to minimize the capillary end effect for a pore-scale CO2 displacement simulation. The Rothman-Keller lattice Boltzmann method with multi-relaxation time is implemented to manipulate a nonflat wall and inflow-outflow boundaries with physically acceptable fluid properties in 2-D microfluidic chip domain. Introducing a mean capillary pressure acting at CO2-water interface to the nonwetting fluid at the outlet effectively prevents CO2 injection pressure from suddenly dropping upon CO2 breakthrough such that the continuous CO2 invasion and the increase of CO2 saturation are allowed. This phenomenon becomes most pronounced at capillary number of logCa = -5.5, while capillary fingering and massive displacement of CO2 prevail at low and high capillary numbers, respectively. Simulations with different domain length in homogeneous and heterogeneous domains reveal that capillary pressure and CO2 saturation near the inlet are reproducible compared with those with a proposed boundary condition. The residual CO2 saturation uniquely follows the increasing tendency with increasing capillary number, corroborated by experimental evidences. The determination of the mean capillary pressure and its sensitivity are also discussed. The proposed boundary condition is commonly applicable to other pore-scale simulations to accurately capture the spatial distribution of nonwetting fluid and corresponding displacement ratio.

  8. Effects of intermediate wettability on entry capillary pressure in angular pores.

    Science.gov (United States)

    Rabbani, Harris Sajjad; Joekar-Niasar, Vahid; Shokri, Nima

    2016-07-01

    Entry capillary pressure is one of the most important factors controlling drainage and remobilization of the capillary-trapped phases as it is the limiting factor against the two-phase displacement. It is known that the entry capillary pressure is rate dependent such that the inertia forces would enhance entry of the non-wetting phase into the pores. More importantly the entry capillary pressure is wettability dependent. However, while the movement of a meniscus into a strongly water-wet pore is well-defined, the invasion of a meniscus into a weak or intermediate water-wet pore especially in the case of angular pores is ambiguous. In this study using OpenFOAM software, high-resolution direct two-phase flow simulations of movement of a meniscus in a single capillary channel are performed. Interface dynamics in angular pores under drainage conditions have been simulated under constant flow rate boundary condition at different wettability conditions. Our results shows that the relation between the half corner angle of pores and contact angle controls the temporal evolution of capillary pressure during the invasion of a pore. By deviating from pure water-wet conditions, a dip in the temporal evolution of capillary pressure can be observed which will be pronounced in irregular angular cross sections. That enhances the pore invasion with a smaller differential pressure. The interplay between the contact angle and pore geometry can have significant implications for enhanced remobilization of ganglia in intermediate contact angles in real porous media morphologies, where pores are very heterogeneous with small shape factors. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  9. The Phase Envelope of Multicomponent Mixtures in the Presence of a Capillary Pressure Difference

    DEFF Research Database (Denmark)

    Sandoval Lemus, Diego Rolando; Yan, Wei; Michelsen, Michael Locht

    2016-01-01

    for test mixtures with wide ranges of compositions at different capillary radii and vapor fractions. The calculation results show that the phase envelope changes everywhere except at the critical point. The bubble point and the lower branch of the dew point show a decrease in the saturation pressure......, whereas the upper branch of the dew point shows an increase. The cricondentherm is shifted to a higher temperature. We also presented a mathematical analysis of the phase envelope shift due to capillary pressure based on linear approximations. The resulting linear approximation equations can predict...... the magnitude of shift, and the approximation is close for the change in the bubble point pressure....

  10. Capillary pressure and saturation relations for supercritical CO2 and brine in sand: High-pressure Pc(Sw) controller/meter measurements and capillary scaling predictions

    Science.gov (United States)

    Tokunaga, Tetsu K.; Wan, Jiamin; Jung, Jong-Won; Kim, Tae Wook; Kim, Yongman; Dong, Wenming

    2013-08-01

    In geologic carbon sequestration, reliable predictions of CO2 storage require understanding the capillary behavior of supercritical (sc) CO2. Given the limited availability of measurements of the capillary pressure (Pc) dependence on water saturation (Sw) with scCO2 as the displacing fluid, simulations of CO2 sequestration commonly rely on modifying more familiar air/H2O and oil/H2O Pc(Sw) relations, adjusted to account for differences in interfacial tensions. In order to test such capillary scaling-based predictions, we developed a high-pressure Pc(Sw) controller/meter, allowing accurate Pc and Sw measurements. Drainage and imbibition processes were measured on quartz sand with scCO2-brine at pressures of 8.5 and 12.0 MPa (45°C), and air-brine at 21°C and 0.1 MPa. Drainage and rewetting at intermediate Sw levels shifted to Pc values that were from 30% to 90% lower than predicted based on interfacial tension changes. Augmenting interfacial tension-based predictions with differences in independently measured contact angles from different sources led to more similar scaled Pc(Sw) relations but still did not converge onto universal drainage and imbibition curves. Equilibrium capillary trapping of the nonwetting phases was determined for Pc = 0 during rewetting. The capillary-trapped volumes for scCO2 were significantly greater than for air. Given that the experiments were all conducted on a system with well-defined pore geometry (homogeneous sand), and that scCO2-brine interfacial tensions are fairly well constrained, we conclude that the observed deviations from scaling predictions resulted from scCO2-induced decreased wettability. Wettability alteration by scCO2 makes predicting hydraulic behavior more challenging than for less reactive fluids.

  11. Determination of clebopride in plasma by capillary gas chromatography-negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Robinson, P R; Jones, M D; Maddock, J

    1988-11-18

    A procedure for the analysis of clebopride in plasma using capillary gas chromatography-negative-ion chemical ionization mass spectrometry has been developed. Employing an ethoxy analogue as internal standard, the two compounds were extracted from basified plasma using dichloromethane. Subsequent reaction with heptafluorobutyryl imidazole produced volatile monoheptafluorobutyryl derivatives whose ammonia negative-ion mass spectra proved ideal for selected-ion monitoring. The recovery of clebopride from plasma at 0.536 nmol/l was found to be 85.5 +/- 0.9% (n = 3) whilst measurement down to 0.268 nmol/l was possible with a coefficient of variation of 7.9%. Plasma levels of the compound are reported in two volunteers following ingestion of 1 mg of clebopride as the malate salt.

  12. Simultaneous measurement of hysteresis in capillary pressure and electric permittivity for multiphase flow through porous media

    NARCIS (Netherlands)

    Plug, W.J.; Slob, E.C.; Bruining, J.; Moreno Tirado, L.M.

    2007-01-01

    We present a tool that simultaneously measures the complex permittivity and the capillary pressure characteristics for multiphase flow. The sample holder is a parallel plate capacitor. A precision component analyzer is used to measure the impedance amplitude and phase angle as a function of

  13. Capillary pressure as a unique function of electric permittivity and water saturation

    NARCIS (Netherlands)

    Plug, W.J.; Slob, E.; Van Turnhout, J.; Bruining, J.

    2007-01-01

    The relation between capillary pressure (Pc) and interfacial area has been investigated by measuring Pc and the electric permittivity at 100 kHz simultaneously as function of the water saturation, (Sw). Drainage and imbibition experiments have been conducted for sand-distilled water-gas (CO2/N2)

  14. An innovative technique for estimating water saturation from capillary pressure in clastic reservoirs

    Science.gov (United States)

    Adeoti, Lukumon; Ayolabi, Elijah Adebowale; James, Logan

    2017-11-01

    A major drawback of old resistivity tools is the poor vertical resolution and estimation of hydrocarbon when applying water saturation (Sw) from historical resistivity method. In this study, we have provided an alternative method called saturation height function to estimate hydrocarbon in some clastic reservoirs in the Niger Delta. The saturation height function was derived from pseudo capillary pressure curves generated using modern wells with complete log data. Our method was based on the determination of rock type from log derived porosity-permeability relationship, supported by volume of shale for its classification into different zones. Leverette-J functions were derived for each rock type. Our results show good correlation between Sw from resistivity based method and Sw from pseudo capillary pressure curves in wells with modern log data. The resistivity based model overestimates Sw in some wells while Sw from the pseudo capillary pressure curves validates and predicts more accurate Sw. In addition, the result of Sw from pseudo capillary pressure curves replaces that of resistivity based model in a well where the resistivity equipment failed. The plot of hydrocarbon pore volume (HCPV) from J-function against HCPV from Archie shows that wells with high HCPV have high sand qualities and vice versa. This was further used to predict the geometry of stratigraphic units. The model presented here freshly addresses the gap in the estimation of Sw and is applicable to reservoirs of similar rock type in other frontier basins worldwide.

  15. High pressure direct synthesis of adipic acid from cyclohexene and hydrogen peroxide via capillary microreactors

    NARCIS (Netherlands)

    Shang, M.; Noël, T.; Su, Y.; Hessel, V.

    2016-01-01

    The direct synthesis of adipic acid from hydrogen peroxide and cyclohexene was investigated in capillary microreactors at high temperature (up to 115°C ) and pressure (up to 70 bar). High temperature was already applied in micro-flow packed-bed reactors for the direct adipic acid synthesis. In our

  16. Negative pressure wound therapy and nurse education.

    Science.gov (United States)

    Cray, Amy

    2017-08-10

    there can be serious consequences for patients if negative pressure wound therapy (NPWT) is performed incorrectly and patient safety must be paramount. The existing literature was found to mainly concentrate on the use of the technology from the patient perspective. This article examines the opinions of nurses who apply the therapy. five staff nurses from different areas with differing experience levels were interviewed in a semi-structured manner. The transcribed interviews were coded, sorted into themes and analysed. the themes were: enhancing knowledge and understanding, managing problematic pumps, formalised and interactive training, and efficacy and healing. There was a lack of standardised training provided for the nurses interviewed. Overall the nurses were aware of the basic evidence behind the treatment but would have liked additional support in this area as well as some practical, less pressured training. This complements the existing literature. nurses are expected to learn difficult and highly specialised skills quickly within a busy ward environment, often with no prior training or preparation. As things can go wrong, with the potential for patient harm, it is vital that nurses get these skills right first time, but it is difficult to do this in a practical, fast and cost-effective way. There is scope for future research in the area and perhaps the development of an online training tool to assist nurses in understanding and undertaking a new procedure.

  17. outcome of foam versus gauze dressings in negative pressure

    African Journals Online (AJOL)

    2013-07-30

    Jul 30, 2013 ... Negative pressure wound therapy (NPWT) is one of .... Presence of necrotic material. If present ..... an alternative dressing interface and other vacuum sources .... edge micro-vascular blood flow: Effects of negative pressure ...

  18. Evaluation of continuous and intermittent myocardial topical negative pressure

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Malmsjö, Malin; Gesslein, Bodil

    2008-01-01

    Topical negative pressure, commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in subcutaneous tissue and skeletal muscle. In wound therapy, intermittent negative pressure is often preferred to continuous negative pressure as tissue exposed to intermit...

  19. Thermodynamics of the multicomponent vapor-liquid equilibrium under capillary pressure difference

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Stenby, Erling Halfdan

    2001-01-01

    We discuss the two-phase multicomponent equilibrium, provided that the phase pressures are different due to the action of capillary forces. We prove the two general properties of such an equilibrium, which have previously been known for a single-component case, however, to the best of our knowledge......, not for the multicomponent mixtures. The importance is emphasized on the space of the intensive variables P, T and mu (i), where the laws of capillary equilibrium have a simple geometrical interpretation. We formulate thermodynamic problems specific to such an equilibrium, and outline changes to be introduced to common...... algorithms of flash calculations in order to solve these problems. Sample calculations show large variation of the capillary properties of the mixture in the very neighborhood of the phase envelope and the restrictive role of the spinodal surface as a boundary for possible equilibrium states with different...

  20. The influence of polydimethylsiloxane curing ratio on capillary pressure in microfluidic devices

    International Nuclear Information System (INIS)

    Viola, Ilenia; Zacheo, Antonella; Arima, Valentina; Aricò, Antonino S.; Cortese, Barbara; Manca, Michele; Zocco, Anna; Taurino, Antonietta; Rinaldi, Ross

    2012-01-01

    Investigations on surface properties of poly(dimethylsiloxane) (PDMS) are justified by its large application ranges especially as coating polymer in fluidic devices. At a micrometer scale, the liquid dynamics is strongly modified by interactions with a solid surface. A crucial parameter for this process is microchannel wettability that can be tuned by acting on surface chemistry and topography. In literature, a number of multi-step, time and cost consuming chemical and physical procedures are reported. Here we selectively modify both wetting and mechanical properties by a single step treatment. Changes of PDMS surface were investigated by X-ray photoelectron spectroscopy and atomic force microscopy and the effects of interface properties on the liquid displacement inside a microfluidic system were evaluated. The negative capillary pressure obtained tailoring the PDMS wettability is believed to be promising to accurately control sample leakage inside integrated lab-on-chip by acting on the liquid confinement and thus to reduce the sample volume, liquid drying as well as cross-contamination during the operation.

  1. A microfluidic circulatory system integrated with capillary-assisted pressure sensors.

    Science.gov (United States)

    Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai

    2017-02-14

    The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.

  2. Modelling of microwave sustained capillary plasma columns at atmospheric pressure

    International Nuclear Information System (INIS)

    Pencheva, M; Petrova, Ts; Benova, E; Zhelyazkov, I

    2006-01-01

    In this work we present a model of argon microwave sustained discharge at high pressure (1 atm), which includes two self-consistently linked parts - electrodynamic and kinetic ones. The model is based on a steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge numerically solved together with Maxwell's equation for an azimuthally symmetric TM surface wave and wave energy balance equation. It is applied for the purpose of theoretical description of the discharge in a stationary state. The phase diagram, the electron energy distribution function as well as the dependences of the electron and heavy particles densities and the mean input power per electron on the electron number density and wave number are presented

  3. The study on pressure oscillation and heat transfer characteristics of oscillating capillary tube heat pipe

    International Nuclear Information System (INIS)

    Kim, Jong Soo; Bui, Ngoc Hung; Jung, Hyun Seok; Lee, Wook Hyun

    2003-01-01

    In the present study, the characteristics of pressure oscillation and heat transfer performance in an oscillating capillary tube heat pipe were experimentally investigated with respect to the heat flux, the charging ratio of working fluid, and the inclination angle to the horizontal orientation. The experimental results showed that the frequency of pressure oscillation was between 0.1 Hz and 1.5 Hz at the charging ratio of 40 vol.%. The saturation pressure of working fluid in the oscillating capillary tube heat pipe increased as the heat flux was increased. Also, as the charging ratio of working fluid was increased, the amplitude of pressure oscillation increased. When the pressure waves were symmetric sinusoidal waves at the charging ratios of 40 vol.% and 60 vol.%, the heat transfer performance was improved. At the charging ratios of 20 vol.% and 80 vol.%, the waveforms of pressure oscillation were more complicated, and the heat transfer performance reduced. At the charging ratio of 40 vol.%, the heat transfer performance of the OCHP was at the best when the inclination angle was 90 .deg., the pressure wave was a sinusoidal waveform, the pressure difference was at the least, the oscillation amplitude was at the least, and the frequency of pressure oscillation was the highest

  4. Uniaxial creep as a control on mercury intrusion capillary pressure in consolidating rock salt

    Energy Technology Data Exchange (ETDEWEB)

    Dewers, Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Leigh, Christi D. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    The nature of geologic disposal of nuclear waste in salt formations requires validated and verified two - phase flow models of transport of brine and gas through intact, damaged, and consolidating crushed salt. Such models exist in oth er realms of subsurface engineering for other lithologic classes (oil and gas, carbon sequestration etc. for clastics and carbonates) but have never been experimentally validated and parameterized for salt repository scenarios or performance assessment. Mo dels for waste release scenarios in salt back - fill require phenomenological expressions for capillary pressure and relative permeability that are expected to change with degree of consolidation, and require experimental measurement to parameterize and vali date. This report describes a preliminary assessment of the influence of consolidation (i.e. volume strain or porosity) on capillary entry pressure in two phase systems using mercury injection capillary pressure (MICP). This is to both determine the potent ial usefulness of the mercury intrusion porosimetry method, but also to enable a better experimental design for these tests. Salt consolidation experiments are performed using novel titanium oedometers, or uniaxial compression cells often used in soil mech anics, using sieved run - of - mine salt from the Waste Isolation Pilot Plant (WIPP) as starting material. Twelve tests are performed with various starting amounts of brine pore saturation, with axial stresses up to 6.2 MPa (%7E900 psi) and temperatures to 90 o C. This corresponds to UFD Work Package 15SN08180211 milestone "FY:15 Transport Properties of Run - of - Mine Salt Backfill - Unconsolidated to Consolidated". Samples exposed to uniaxial compression undergo time - dependent consolidation, or creep, to various deg rees. Creep volume strain - time relations obey simple log - time behavior through the range of porosities (%7E50 to 2% as measured); creep strain rate increases with temperature and applied stress as

  5. Aerosol penetration through capillaries and leaks: experimental studies on the influence of pressure

    International Nuclear Information System (INIS)

    Morton, D.A.V.; Mitchell, J.P.

    1995-01-01

    It is important to understand the movement of aerosols through ultrafine leak-paths with dimensions of similar order to the gas-borne particles when assessing the validity of leak-testing procedures for transport containers for radioactive materials. Experiments have been undertaken to investigate the penetration of micron-sized airborne particles using glass micro-capillaries as model leak-paths. Previous studies demonstrated a simple relationship between air leakage and total particle penetration rates at a constant driving pressure (100 kPa). The present work has demonstrated the importance of pressure in regulating the rate at which the leak-path is plugged by deposited particles. Much of this deposition appears to take place at the entrances of the capillaries where the air-flow converges. (author)

  6. Application of vacuum-assisted closure in seawater-immersed wound treatment under different negative pressures.

    Science.gov (United States)

    Cao, L; Peng, M M; Sun, J J; Yu, X C; Shi, B

    2015-06-11

    The therapeutic effect of vacuum-assisted closure (VAC) has been confirmed in many types of complex wounds, but there are few relevant reports regarding seawater-immersed wounds. The aim of this study was to determine the effect of VAC on seawater-immersed wound healing under different negative pressures and explore the optimal negative pressure value. Four purebred miniature pigs were used as the experimental animal models. Four acute, symmetrical wounds were made on each side of the spine and designated as the experimental group (wounds with 2 h of seawater immersion) and the control group (wounds without seawater immersion). Wounds were divided into a conventional dressing group and 3 further groups with different VAC therapies (negative pressure at either 120, 180, or 240 mmHg). The extent of wound healing, and speed of granulation growth and re-epithelialization were measured. Bacterial flora distribution in the wounds was observed, and fibronectin levels in the exudate of the wounds were tested. Results showed that seawater immersion aggravated wound injury and that VAC therapy with 180 mmHg negative pressure induced the fastest epidermis migration, obvious edema elimination, significant capillary proliferation, and the highest level of fibronectin, and that in wounds, the proportion of Gram-negative bacteria tended to decrease and that of Gram-positive bacteria tended to increase. Our results show that VAC promotes seawater-immersed wound healing and that 180 mmHg negative pressure may be optimal for wound healing.

  7. Destruction of Bacillus subtilis cells using an atmospheric-pressure dielectric capillary electrode discharge plasma

    International Nuclear Information System (INIS)

    Panikov, N.S.; Paduraru, S.; Crowe, R.; Ricatto, P.J.; Christodoulatos, C.; Becker, K.

    2002-01-01

    The results of experiments aimed at the investigation of the destruction of spore-forming bacteria, which are believed to be among the most resistant microorganisms, using a novel atmospheric-pressure dielectric capillary electrode discharge plasma are reported. Various well-characterized cultures of Bacillus subtilis were prepared, subjected to atmospheric-pressure plasma jets emanating from a plasma shower reactor operated either in He or in air (N 2 /O 2 mixture) at various power levels and exposure times, and analyzed after plasma treatment. Reductions in colony-forming units ranged from 10 4 (He plasma) to 10 8 (air plasma) for plasma exposure times of less than 10 minutes. (author)

  8. Capillary pressure across a pore throat in the presence of surfactants

    KAUST Repository

    Jang, Junbong

    2016-11-22

    Capillarity controls the distribution and transport of multiphase and immiscible fluids in soils and fractured rocks; therefore, capillarity affects the migration of nonaqueous contaminants and remediation strategies for both LNAPLs and DNAPLs, constrains gas and oil recovery, and regulates CO2 injection and geological storage. Surfactants alter interfacial tension and modify the invasion of pores by immiscible fluids. Experiments are conducted to explore the propagation of fluid interfaces along cylindrical capillary tubes and across pore constrictions in the presence of surfactants. Measured pressure signatures reflect the interaction between surface tension, contact angle, and the pore geometry. Various instabilities occur as the interface traverses the pore constriction, consequently, measured pressure signatures differ from theoretical trends predicted from geometry, lower capillary pressures are generated in advancing wetting fronts, and jumps are prone to under-sampling. Contact angle and instabilities are responsible for pronounced differences between pressure signatures recorded during advancing and receding tests. Pressure signatures gathered with surfactant solutions suggest changes in interfacial tension at the constriction; the transient surface tension is significantly lower than the value measured in quasi-static conditions. Interface stiffening is observed during receding fronts for solutions near the critical micelle concentration. Wetting liquids tend to form plugs at pore constrictions after the invasion of a nonwetting fluid; plugs split the nonwetting fluid into isolated globules and add resistance against fluid flow.

  9. Atmospheric-pressure dielectric barrier discharge with capillary injection for gas-phase nanoparticle synthesis

    International Nuclear Information System (INIS)

    Ghosh, Souvik; Liu, Tianqi; Bilici, Mihai; Cole, Jonathan; Huang, I-Min; Sankaran, R Mohan; Staack, David; Mariotti, Davide

    2015-01-01

    We present an atmospheric-pressure dielectric barrier discharge (DBD) reactor for gas-phase nanoparticle synthesis. Nickel nanoparticles are synthesized by homogenous nucleation from nickelocene vapor and characterized online by aerosol mobility measurements. The effects of residence time and precursor concentration on particle growth are studied. We find that narrower distributions of smaller particles are produced by decreasing the precursor concentration, in agreement with vapor nucleation theory, but larger particles and aggregates form at higher gas flow rates where the mean residence time should be reduced, suggesting a cooling effect that leads to enhanced particle nucleation. In comparison, incorporating a capillary gas injector to alter the velocity profile is found to significantly reduce particle size and agglomeration. These results suggest that capillary gas injection is a better approach to decreasing the mean residence time and narrowing the residence time distribution for nanoparticle growth by producing a sharp and narrow velocity profile. (paper)

  10. Retention behavior of neutral solutes in pressurized flow-driven capillary electrochromatography using an ODS column.

    Science.gov (United States)

    Nakagawa, Hiroyuki; Kitagawa, Shinya; Araki, Shuki; Ohtani, Hajime

    2006-02-01

    Several alkyl benzenes are separated by pressurized flow-driven capillary electrochromatography using a temperature-controlled capillary column packed with octadecyl siloxane-modified silica gel, and the effect of applied voltage on the retention is investigated. The van't Hoff plot shows good linearity at the column temperature between 305 and 330 K under applications from -6 to +6 kV. The applied voltage causes a relatively large variation in the enthalpy and the entropy of transfer of the solute from the mobile phase to the stationary phase (> 20%). However, the direction of variation in the enthalpy is almost opposite to that in the entropy, both of which might compensate each other. Therefore, the retention factor is not significantly varied (< 4%) by the application of voltage.

  11. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    International Nuclear Information System (INIS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Zenhausern, Frederic; Rivera, Andrew; Birdsell, Dawn N; Wagner, David M

    2015-01-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30–100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis. (paper)

  12. An Affordable Custom-Built Negative Pressure Wound Therapy

    African Journals Online (AJOL)

    Negative pressure wound therapy (NPWT) is a well- established modality for treating complex wounds (1). ... a negative pressure which causes a characteristic shrinking of the gauze, indicating that the device ... We have applied this simplified technique of NPWT in patients with diabetic foot ulcers and open fractures.

  13. 21 CFR 868.5935 - External negative pressure ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External negative pressure ventilator. 868.5935 Section 868.5935 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... ventilator. (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a...

  14. Capillary pressure-saturation relationships for porous granular materials: Pore morphology method vs. pore unit assembly method

    Science.gov (United States)

    Sweijen, Thomas; Aslannejad, Hamed; Hassanizadeh, S. Majid

    2017-09-01

    In studies of two-phase flow in complex porous media it is often desirable to have an estimation of the capillary pressure-saturation curve prior to measurements. Therefore, we compare in this research the capability of three pore-scale approaches in reproducing experimentally measured capillary pressure-saturation curves. To do so, we have generated 12 packings of spheres that are representative of four different glass-bead packings and eight different sand packings, for which we have found experimental data on the capillary pressure-saturation curve in the literature. In generating the packings, we matched the particle size distributions and porosity values of the granular materials. We have used three different pore-scale approaches for generating the capillary pressure-saturation curves of each packing: i) the Pore Unit Assembly (PUA) method in combination with the Mayer and Stowe-Princen (MS-P) approximation for estimating the entry pressures of pore throats, ii) the PUA method in combination with the hemisphere approximation, and iii) the Pore Morphology Method (PMM) in combination with the hemisphere approximation. The three approaches were also used to produce capillary pressure-saturation curves for the coating layer of paper, used in inkjet printing. Curves for such layers are extremely difficult to determine experimentally, due to their very small thickness and the presence of extremely small pores (less than one micrometer in size). Results indicate that the PMM and PUA-hemisphere method give similar capillary pressure-saturation curves, because both methods rely on a hemisphere to represent the air-water interface. The ability of the hemisphere approximation and the MS-P approximation to reproduce correct capillary pressure seems to depend on the type of particle size distribution, with the hemisphere approximation working well for narrowly distributed granular materials.

  15. Pressure Field Around Underwater Negative Streamers

    Czech Academy of Sciences Publication Activity Database

    Hoffer, Petr; Koláček, Karel; Lukeš, Petr; Stelmashuk, Vitaliy

    2015-01-01

    Roč. 43, č. 5 (2015), s. 1787-1792 ISSN 0093-3813 R&D Projects: GA ČR(CZ) GA15-12987S Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100431203 Program:M Institutional support: RVO:61389021 Keywords : Interferometry * plasma generation * pressure measurement * water Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.958, year: 2015

  16. Establishing a quantitative functional relationship between capillary pressure, saturation and interfacial area. 1997 annual progress report

    International Nuclear Information System (INIS)

    Montemagno, C.D.

    1997-01-01

    'There is a fundamental knowledge gap associated with the in situ remediation of non-aqueous phase pollutants. Currently it is not possible to accurately determine the interfacial surface area of non-aqueous contaminants. As a result it is impossible to (1) accurately establish the health and environmental risk associated with the pollution: (2) precisely quantify and evaluate the potential efficacy of various in situ treatment technologies; and (3) conduct reliable performance assessments of the applied remediation technology during and after the clean-up. The global goal of this investigation is to try to remedy these shortcomings through the development of a formalized functional relationship between interfacial area (a), phase saturation (S) and capillary pressure (P). The development of this relationship will allow the direct determination of the fluid-fluid interfacial area from field measurements. Quantitative knowledge of the surface area of the non-aqueous phase pollutant facilitates accurate predictions of both the rate of dissolution and the contact area available for treatment. In addition. if saturation and capillary pressure measurements are made during the remediation process. both the spatial and temporal effectiveness of the remediation technology can be quantified. This information can then be used to optimize the restoration program. The project objective will be achieved through an integrated and focused research program that is comprised of theoretical computational and experimental efforts. These efforts are organized into a framework of four tasks: (1) improve on newly developed laboratory techniques to quantify and directly measure the functional relationship between phase interfacial area (a), saturation (S) and capillary pressure (P). (2) Develop new computational algorithms in conjunction with laboratory measurements to predict P, S and a. (3) Test existing theory and develop new theory to describe the relationship between P, S and a at

  17. Fabrication of self-enclosed nanochannels based on capillary-pressure balance mechanism

    Science.gov (United States)

    Kou, Yu; Sang, Aixia; Li, Xin; Wang, Xudi

    2017-10-01

    Polymer-based micro/nano fluidic devices are becoming increasingly important to biological applications and fluidic control. In this paper, we propose a self-enclosure method for the fabrication of large-area nanochannels without external force by using a capillary-pressure balance mechanism. The melt polymer coated on the nanogrooves fills into the trenches inevitably and the air in the trenches is not excluded but compressed, which leads to an equilibrium state between pressure of the trapped air and capillary force of melt polymer eventually, resulting in the channels’ formation. A pressure balance model was proposed to elucidate the unique self-sealing phenomenon and the criteria for the design and construction of sealed channels was discussed. According to the bonding mechanism investigated using the volume of fluid (VOF) simulation and experiments, we can control the dimension of sealed channels by varying the baking condition. This fabrication technique has great potential for low-cost and mass production of polymeric-based micro/nano fluidic devices.

  18. Exact solution of unsteady flow generated by sinusoidal pressure gradient in a capillary tube

    Directory of Open Access Journals (Sweden)

    M. Abdulhameed

    2015-12-01

    Full Text Available In this paper, the mathematical modeling of unsteady second grade fluid in a capillary tube with sinusoidal pressure gradient is developed with non-homogenous boundary conditions. Exact analytical solutions for the velocity profiles have been obtained in explicit forms. These solutions are written as the sum of the steady and transient solutions for small and large times. For growing times, the starting solution reduces to the well-known periodic solution that coincides with the corresponding solution of a Newtonian fluid. Graphs representing the solutions are discussed.

  19. SIMULATION OF NEGATIVE PRESSURE WAVE PROPAGATION IN WATER PIPE NETWORK

    Directory of Open Access Journals (Sweden)

    Tang Van Lam

    2017-11-01

    Full Text Available Subject: factors such as pipe wall roughness, mechanical properties of pipe materials, physical properties of water affect the pressure surge in the water supply pipes. These factors make it difficult to analyze the transient problem of pressure evolution using simple programming language, especially in the studies that consider only the magnitude of the positive pressure surge with the negative pressure phase being neglected. Research objectives: determine the magnitude of the negative pressure in the pipes on the experimental model. The propagation distance of the negative pressure wave will be simulated by the valve closure scenarios with the help of the HAMMER software and it is compared with an experimental model to verify the quality the results. Materials and methods: academic version of the Bentley HAMMER software is used to simulate the pressure surge wave propagation due to closure of the valve in water supply pipe network. The method of characteristics is used to solve the governing equations of transient process of pressure change in the pipeline. This method is implemented in the HAMMER software to calculate the pressure surge value in the pipes. Results: the method has been applied for water pipe networks of experimental model, the results show the affected area of negative pressure wave from valve closure and thereby we assess the largest negative pressure that may appear in water supply pipes. Conclusions: the experiment simulates the water pipe network with a consumption node for various valve closure scenarios to determine possibility of appearance of maximum negative pressure value in the pipes. Determination of these values in real-life network is relatively costly and time-consuming but nevertheless necessary for identification of the risk of pipe failure, and therefore, this paper proposes using the simulation model by the HAMMER software. Initial calibration of the model combined with the software simulation results and

  20. Detection of elevated pulmonary capillary wedge pressure in elderly patients with various cardiac disorders by the Valsalva manoeuvre.

    NARCIS (Netherlands)

    Remmen, J.J.; Aengevaeren, W.R.M.; Verheugt, F.W.A.; Jansen, R.W.M.M.

    2006-01-01

    In the present study, we assessed whether elevated (> or =15 mmHg) PCWP (pulmonary capillary wedge pressure) can be detected using the blood pressure response to the Valsalva manoeuvre in a group of elderly patients with various cardiac disorders, including atrial fibrillation and valvular heart

  1. Estimation of relative permeability and capillary pressure from mass imbibition experiments

    Science.gov (United States)

    Alyafei, Nayef; Blunt, Martin J.

    2018-05-01

    We perform spontaneous imbibition experiments on three carbonates - Estaillades, Ketton, and Portland - which are three quarry limestones that have very different pore structures and span wide range of permeability. We measure the mass of water imbibed in air saturated cores as a function of time under strongly water-wet conditions. Specifically, we perform co-current spontaneous experiments using a highly sensitive balance to measure the mass imbibed as a function of time for the three rocks. We use cores measuring 37 mm in diameter and three lengths of approximately 76 mm, 204 mm, and 290 mm. We show that the amount imbibed scales as the square root of time and find the parameter C, where the volume imbibed per unit cross-sectional area at time t is Ct1/2. We find higher C values for higher permeability rocks. Employing semi-analytical solutions for one-dimensional flow and using reasonable estimates of relative permeability and capillary pressure, we can match the experimental data. We finally discuss how, in combination with conventional measurements, we can use theoretical solutions and imbibition measurements to find or constrain relative permeability and capillary pressure.

  2. The phase diagram of water at negative pressures: virtual ices.

    Science.gov (United States)

    Conde, M M; Vega, C; Tribello, G A; Slater, B

    2009-07-21

    The phase diagram of water at negative pressures as obtained from computer simulations for two models of water, TIP4P/2005 and TIP5P is presented. Several solid structures with lower densities than ice Ih, so-called virtual ices, were considered as possible candidates to occupy the negative pressure region of the phase diagram of water. In particular the empty hydrate structures sI, sII, and sH and another, recently proposed, low-density ice structure. The relative stabilities of these structures at 0 K was determined using empirical water potentials and density functional theory calculations. By performing free energy calculations and Gibbs-Duhem integration the phase diagram of TIP4P/2005 was determined at negative pressures. The empty hydrates sII and sH appear to be the stable solid phases of water at negative pressures. The phase boundary between ice Ih and sII clathrate occurs at moderate negative pressures, while at large negative pressures sH becomes the most stable phase. This behavior is in reasonable agreement with what is observed in density functional theory calculations.

  3. Capillary pressure - saturation relations in quartz and carbonate sands: Limitations for correlating capillary and wettability influences on air, oil, and supercritical CO2 trapping

    Science.gov (United States)

    Tokunaga, T. K.; Wang, S.; Wan, J.; Dong, W.; Kim, Y.

    2016-12-01

    Capillary pressure (Pc) - saturation (Sw) relations are essential for predicting equilibrium and flow of immiscible fluid pairs in soils and deeper geologic formations. In systems that are difficult to measure, behavior is often estimated based on capillary scaling of easily measured Pc-Sw relations (e.g., air-water, and oil-water), yet the reliability of such approximations needs to be examined. In this study, seventeen sets of brine drainage and imbibition curves were measured with air-brine, decane-brine, and supercritical (sc) CO2-brine in homogeneous quartz and carbonate sands, using porous plate systems under ambient (0.1 MPa, 23 °C) and reservoir (12.0 MPa, 45 °C) conditions. Comparisons between these measurements showed significant differences in residual nonwetting phase saturation, Snw,r. Through applying capillary scaling, changes in interfacial properties were indicated, particularly wettability. With respect to the residual trapping of the nonwetting phases, Snwr, CO2 > Snwr, decane > Snwr, air. Decane-brine and scCO2-brine Pc-Sw curves deviated significantly from predictions assuming hydrophilic interactions. Moreover, neither the scaled capillary behavior nor Snw,r for scCO2-brine were well represented by decane-brine, apparently because of differences in wettability and viscosities, indicating limitations for using decane (and other organic liquids) as a surrogate fluid in studies intended to apply to geological carbon sequestration. Thus, challenges remain in applying scaling for predicting capillary trapping and multiphase displacement processes across such diverse fields as vadose zone hydrology, enhanced oil recovery, and geologic carbon sequestration.

  4. Responses to negative pressure surrounding the neck in anesthetized animals.

    Science.gov (United States)

    Wolin, A D; Strohl, K P; Acree, B N; Fouke, J M

    1990-01-01

    Continuous positive pressure applied at the nose has been shown to cause a decrease in upper airway resistance. The present study was designed to determine whether a similar positive transmural pressure gradient, generated by applying a negative pressure at the body surface around the neck, altered upper airway patency. Studies were performed in nine spontaneously breathing anesthetized supine dogs. Airflow was measured with a pneumotachograph mounted on an airtight muzzle placed over the nose and mouth of each animal. Upper airway pressure was measured as the differential pressure between the extrathoracic trachea and the inside of the muzzle. Upper airway resistance was monitored as an index of airway patency. Negative pressure (-2 to -20 cmH2O) was applied around the neck by using a cuirass extending from the jaw to the thorax. In each animal, increasingly negative pressures were transmitted to the airway wall in a progressive, although not linear, fashion. Decreasing the pressure produced a progressive fall in upper airway resistance, without causing a significant change in respiratory drive or respiratory timing. At -5 cmH2O pressure, there occurred a significant fall in upper airway resistance, comparable with the response of a single, intravenous injection of sodium cyanide (0.5-3.0 mg), a respiratory stimulant that produces substantial increases in respiratory drive. We conclude that upper airway resistance is influenced by the transmural pressure across the airway wall and that such a gradient can be accomplished by making the extraluminal pressure more negative.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Diamond synthesis at atmospheric pressure by microwave capillary plasma chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Hemawan, Kadek W.; Gou, Huiyang; Hemley, Russell J. [Geophysical Laboratory, Carnegie Institution of Washington, 5251 Broad Branch Rd., NW, Washington, DC 20015 (United States)

    2015-11-02

    Polycrystalline diamond has been synthesized on silicon substrates at atmospheric pressure, using a microwave capillary plasma chemical vapor deposition technique. The CH{sub 4}/Ar plasma was generated inside of quartz capillary tubes using 2.45 GHz microwave excitation without adding H{sub 2} into the deposition gas chemistry. Electronically excited species of CN, C{sub 2}, Ar, N{sub 2}, CH, H{sub β}, and H{sub α} were observed in the emission spectra. Raman measurements of deposited material indicate the formation of well-crystallized diamond, as evidenced by the sharp T{sub 2g} phonon at 1333 cm{sup −1} peak relative to the Raman features of graphitic carbon. Field emission scanning electron microscopy images reveal that, depending on the growth conditions, the carbon microstructures of grown films exhibit “coral” and “cauliflower-like” morphologies or well-facetted diamond crystals with grain sizes ranging from 100 nm to 10 μm.

  6. Pressure-accelerated azide-alkyne cycloaddition: micro capillary versus autoclave reactor performance.

    Science.gov (United States)

    Borukhova, Svetlana; Seeger, Andreas D; Noël, Timothy; Wang, Qi; Busch, Markus; Hessel, Volker

    2015-02-01

    Pressure effects on regioselectivity and yield of cycloaddition reactions have been shown to exist. Nevertheless, high pressure synthetic applications with subsequent benefits in the production of natural products are limited by the general availability of the equipment. In addition, the virtues and limitations of microflow equipment under standard conditions are well established. Herein, we apply novel-process-window (NPWs) principles, such as intensification of intrinsic kinetics of a reaction using high temperature, pressure, and concentration, on azide-alkyne cycloaddition towards synthesis of Rufinamide precursor. We applied three main activation methods (i.e., uncatalyzed batch, uncatalyzed flow, and catalyzed flow) on uncatalyzed and catalyzed azide-alkyne cycloaddition. We compare the performance of two reactors, a specialized autoclave batch reactor for high-pressure operation up to 1800 bar and a capillary flow reactor (up to 400 bar). A differentiated and comprehensive picture is given for the two reactors and the three methods of activation. Reaction speedup and consequent increases in space-time yields is achieved, while the process window for favorable operation to selectively produce Rufinamide precursor in good yields is widened. The best conditions thus determined are applied to several azide-alkyne cycloadditions to widen the scope of the presented methodology. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A total pressure-saturation formulation of two-phase flow incorporating dynamic effects in the capillary-pressure-saturation relationship

    Energy Technology Data Exchange (ETDEWEB)

    Dahle, H K; Celia, M A; Hassanizadeh, S M; Karlsen, K H

    2002-07-01

    New theories suggest that the relationship between capillary pressure and saturation should be enhanced by a dynamic term that is proportional to the time rate of change of saturation. This so-called dynamic capillary pressure formulation is supported by laboratory experiments, and can be included in various forms of the governing equations for two-phase flow in porous media. An extended model of two-phase flow in porous media may be developed based on fractional flow curves and a total pressure - saturation description that includes the dynamic capillary pressure terms. A dimensionless form of the resulting equation set provides an ideal tool to study the relative importance of the dynamic capillary pressure effect. This equation provides a rich set of mathematical research questions, and numerical solutions to the equation provide insights into the behavior of two-phase immiscible flow. For typical two-phase flow systems, dynamic capillary pressure acts to retard infiltration fronts, with responses dependent on system parameters including boundary conditions. Recent theoretical work suggests that the traditional algebraic relationship between capillary pressure and saturation may be inadequate. Instead, a so-called dynamic capillary pressure formulation is needed, where capillary pressure is defined as a thermodynamic variable, and the difference between phase pressures is only equal to the capillary pressure at equilibrium. Under dynamic conditions, the disequilibrium between phase-pressure differences and the capillary pressure is taken to be proportional to the time rate of change of saturation. A recent study by Hassanizadeh et al. presents experimental evidence, culled from the literature, to support this claim. Numerical simulations using dynamic pore-scale network models and upscaling also support the claim. Hassanizadeh et al. also presented numerical solutions for an enhanced version of Richards' equation that included the dynamic terms. A preliminary

  8. Capillary pressure - saturation relations for supercritical CO2 and brine: Implications for capillary/residual trapping in carbonate reservoirs during geologic carbon sequestration

    Science.gov (United States)

    Wang, S.; Tokunaga, T. K.

    2014-12-01

    In geologic carbon sequestration (GCS), data on capillary pressure (Pc) - saturation (Sw) relations are routinely needed to appraise reservoir processes. Capillarity and its hysteresis have been often experimentally studied in oil-water, gas-water and three phase gas-oil-water systems, but fewer works have been reported on scCO2-water under in-situ reservoir conditions. Here, Pc-Sw relations of supercritical (sc) CO2 displacing brine, and brine rewetting the porous medium to trap scCO2 were studied to understand CO2 transport and trapping behavior in carbonate reservoirs under representative reservoir conditions. High-quality drainage and imbibition (and associated capillary pressure hysteresis) curves were measured under elevated temperature and pressure (45 ºC, 8.5 and 12 MPa) for scCO2-brine as well as at room temperature and pressure (23 ºC, 0.1 MPa) for air-brine in unconsolidated limestone and dolomite sand columns using newly developed semi-automated multistep outflow-inflow porous plate apparatus. Drainage and imbibition curves for scCO2-brine deviated from the universal scaling curves for hydrophilic interactions (with greater deviation under higher pressure) and shifted to lower Pc than predicted based on interfacial tension (IFT) changes. Augmented scaling incorporating differences in IFT and contact angle improved the scaling results but the scaled curves still did not converge onto the universal curves. Equilibrium residual trapping of the nonwetting phase was determined at Pc =0 during imbibition. The capillary-trapped amounts of scCO2 were significantly larger than for air. It is concluded that the deviations from the universal capillary scaling curves are caused by scCO2-induced wettability alteration, given the fact that pore geometry remained constant and IFT is well constrained. In-situ wettability alteration by reactive scCO2 is of critical importance and must be accounted for to achieve reliable predictions of CO2 behavior in GCS reservoirs.

  9. A novel method for calculating the dynamic capillary force and correcting the pressure error in micro-tube experiment.

    Science.gov (United States)

    Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan

    2017-11-29

    Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.

  10. Signal-Pressure Curves of Cascaded Four-Wave Mixing in Gas-Filled Capillary by fs Pulses

    International Nuclear Information System (INIS)

    Chen Baozhen; Huang Zuqia

    2005-01-01

    The theoretical framework for the cascaded four waves mixing (CFWM) in gas-filled capillary by fs pulses is constructed. Based on the theoretical framework, the signal-pressure curves (SPC) of the CFWM in gas-filled capillary by fs pulses are calculated. With a comparison between the theoretical and experimental SPC we have discussed the influence of the walk-off and phase modulation on the SPC. At the same time, we have discussed the possible origin of the first three peaks of the SPC.

  11. Negative pressure dressing combined with a traditional approach for ...

    African Journals Online (AJOL)

    2011-07-21

    Jul 21, 2011 ... Deep burns of the calvarium due to high-voltage electrical current present serious therapeutic challenges in the healing. In this study, as an alternative approach to the treatment of burned skull, negative pressure dressing is used to facilitate separation of the necrotic bones from healthy margins of the ...

  12. Negative interstitial pressure in the peritendinous region during exercise

    DEFF Research Database (Denmark)

    Langberg, Henning; Skovgaard, D; Bülow, J

    1999-01-01

    of these observations, microdialysis was performed in the peritendinous region with a colloid osmotic active substance (Dextran 70, 0.1 g/ml) added to the perfusate with the aim of counteracting the negative tissue pressure. Dialysate volume was found to be fully restored (100 +/- 4%) during exercise. It is concluded...

  13. The use of negative pressure wave treatment in athlete recovery ...

    African Journals Online (AJOL)

    Background: Athletes need to recover fully to maximise performance in competitive sport. Athletes who replenish more quickly and more efficiently are able to train harder and more intensely. Elite athletes subjectively report positive results using lower body negative pressure (LBNP) treatment as an alternate method for ...

  14. Controlling a negative loaded hydraulic cylinder using pressure feedback

    DEFF Research Database (Denmark)

    Hansen, M.R.; Andersen, T.O.

    2010-01-01

    This paper is concerned with the inherent oscillatory nature of pressure compensated velocity control of a hydraulic cylinder subjected to a negative load and suspended by means of an over-center valve. Initially, a linearized stability analysis of such a hydraulic circuit is carried out clearly ...... in a nonlinear time domain simulation model validating the linear stability analysis....

  15. Pulmonary arterial pressure and right ventricular dilatation independently determine tricuspid valve insufficiency severity in pre-capillary pulmonary hypertension.

    Science.gov (United States)

    De Meester, Pieter; Van De Bruaene, Alexander; Delcroix, Marion; Belmans, Ann; Herijgers, Paul; Voigt, Jens-Uwe; Budts, Werner

    2012-11-01

    Elevated pulmonary artery systolic pressure (PASP) causes functional tricuspid valve insufficiency (TI). However, the differential contribution of pressure load and right ventricular (RV) dilatation is not well established. The study aim was to evaluate both variables in relation to TI. A cross-sectional study was performed of consecutive transthoracic echocardiographic studies of patients with pre-capillary pulmonary hypertension (PH). Both, demographic data and echocardiographic RV parameters were reviewed. TI was graded semi-quantitatively with color Doppler flow imaging. Trend analyses for TI severity (TI grade 0/4, 1/4, 2/4, 3/4, or 4/4) were performed. A proportional odds logistic regression analysis was carried out to identify independent predictors of TI severity. Eighty-one patients (56 females, 25 males; mean age 60 +/- 15 years) with pre-capillary PH were evaluated. Patients with more severe TI had a significantly lower body mass index, a lower mean systemic blood pressure, a shorter pulmonary acceleration time, a higher tricuspid regurgitant gradient, and a more dilated right ventricle. From the echocardiographic parameters, RV dilatation (p = 0.0143) and the tricuspid regurgitant gradient (p = 0.0026) were independently related to the degree of TI. In patients with pre-capillary PH, PASP and RV dilatation were both related to the increasing severity of TI. When focusing on TI to improve the prognosis of patients with pre-capillary PH, both PASP and RV dimensions should be taken into consideration.

  16. Indirect Determination of Vapor Pressures by Capillary Gas-Liquid Chromatography: Analysis of the Reference Vapor-Pressure Data and Their Treatment

    Czech Academy of Sciences Publication Activity Database

    Růžička, K.; Koutek, Bohumír; Fulem, M.; Hoskovec, Michal

    2012-01-01

    Roč. 57, č. 5 (2012), s. 1349-1368 ISSN 0021-9568 R&D Projects: GA ČR GA203/09/1327 Institutional research plan: CEZ:AV0Z40550506 Keywords : vapor pressures * capillary gas–liquid chromatography * reference data * relative retention time Subject RIV: CC - Organic Chemistry Impact factor: 2.004, year: 2012

  17. Flow rate impacts on capillary pressure and interface curvature of connected and disconnected fluid phases during multiphase flow in sandstone

    Science.gov (United States)

    Herring, Anna L.; Middleton, Jill; Walsh, Rick; Kingston, Andrew; Sheppard, Adrian

    2017-09-01

    We investigate capillary pressure-saturation (PC-S) relationships for drainage-imbibition experiments conducted with air (nonwetting phase) and brine (wetting phase) in Bentheimer sandstone cores. Three different flow rate conditions, ranging over three orders of magnitude, are investigated. X-ray micro-computed tomographic imaging is used to characterize the distribution and amount of fluids and their interfacial characteristics. Capillary pressure is measured via (1) bulk-phase pressure transducer measurements, and (2) image-based curvature measurements, calculated using a novel 3D curvature algorithm. We distinguish between connected (percolating) and disconnected air clusters: curvatures measured on the connected phase interfaces are used to validate the curvature algorithm and provide an indication of the equilibrium condition of the data; curvature and volume distributions of disconnected clusters provide insight to the snap-off processes occurring during drainage and imbibition under different flow rate conditions.

  18. Direct Numerical Simulations of Dynamic Drainage and Imbibition to Investigate Capillary Pressure-Saturation-Interfacial Area Relation

    Science.gov (United States)

    Konangi, S.; Palakurthi, N. K.; Karadimitriou, N.; Comer, K.; Ghia, U.

    2017-12-01

    We present results of pore-scale direct numerical simulations (DNS) of drainage and imbibition in a quasi-two-dimensional (40µm thickness) porous medium with a randomly distributed packing of cylindrical obstructions. The Navier-Stokes (NS) equations are solved in the pore space on an Eulerian mesh using the open-source finite-volume computational fluid dynamics (CFD) code, OpenFOAM. The Volume-of-Fluid (VOF) method is employed to track the evolution of the fluid-fluid interface; a static contact angle is used to account for wall adhesion. From the DNS data, we focus on the macroscopic capillary pressure-saturation (Pc-Sw) relation, which is known to be hysteretic, i.e., this relation is flow process (such as drainage, imbibition and scanning curves) and history dependent. In order to overcome the problem of hysteresis, extended theories of multiphase flow hypothesized that the inclusion of specific interfacial area as a state variable will result in a unique relation between capillary pressure, saturation and interfacial area (Pc-Sw-awn). We study the role of specific interfacial area on hysteresis in the macroscopic Pc-Sw relation under non-equilibrium (dynamic) conditions. Under dynamic conditions, capillary pressure depends on the rate of change of the wetting phase saturation, and the dynamic Pc-Sw relation includes the changes caused by viscous effects. Simulations of drainage and imbibition are performed for two capillary numbers by controlling the flow rate of the non-wetting (polydimenthlysiloxane oil) and wetting (water) fluids. From these simulations, the Pc-Sw curves will be estimated; the Pc-S-awn surface will be constructed to determine whether the data points from drainage and imbibition processes fall on a unique surface under transient conditions. Different macroscopic capillary pressure definitions based on phase-averaged pressures and interfacial area will be evaluated. Understanding macroscopic capillary pressure definitions and the uniqueness

  19. Proposed application of lower body negative pressure to cardiology

    Science.gov (United States)

    Schmidt, E. V.; Debusk, R. F.; Popp, R. L.

    1975-01-01

    Potential medical applications are presented of lower body negative pressure to the evaluation and treatment of cardiac patients. The essential features of an LBNP unit and the basic cardiovascular physiology of lower body negative pressure (LBNP) testing are described. Some of the results of previous spaceflight experiences and bedrest studies are summarized. The deconditioning effects of weightlessness experienced by orbiting astronauts are compared with the effects of bedrest restrictions prescribed for convalescing cardiac patients. The potential of LBNP for evaluating both pharmacological and physical activity regimens was examined, particularly in relation to post-myocardial infarction and coronary artery bypass patients. Applications of LBNP to the cardiac catheterization laboratory and the out-patient follow-up of cardiac patients are proposed.

  20. Rapid Onset Acute Epiglottitis Leading to Negative Pressure Pulmonary Edema

    Directory of Open Access Journals (Sweden)

    V Saraswat

    2007-01-01

    Full Text Available Pulmonary edema is a potentially life-threatening complication of acute airway obstruction. It develops rapidly, without warning, in young healthy individuals. Two forms of post-obstructive pulmonary edema (POPE (also known as negative pressure pulmonary edema, NPPE have been identified. POPE I follows sudden, severe upper airway obstruction. POPE II occurs following surgical relief of chronic upper airway obstruction. Treatment for both is supportive. Full and rapid recovery can be expected with appropriate management. A case report of a middle aged man with acute onset epiglottitis who developed negative pressure pulmonary edema after intubation is presented. The report includes a brief discussion on etiology, clinical features and management dilemma of acute upper airway obstruction.

  1. Rapid Onset Acute Epiglottitis Leading to Negative Pressure Pulmonary Edema

    OpenAIRE

    V Saraswat; P V Madhu; Suresh S Kumar

    2007-01-01

    Pulmonary edema is a potentially life-threatening complication of acute airway obstruction. It develops rapidly, without warning, in young healthy individuals. Two forms of post-obstructive pulmonary edema (POPE) (also known as negative pressure pulmonary edema, NPPE) have been identified. POPE I follows sudden, severe upper airway obstruction. POPE II occurs following surgical relief of chronic upper airway obstruction. Treatment for both is supportive. Full and rapid recovery can be expecte...

  2. Negative-pressure wound therapy with instillation: international consensus guidelines.

    Science.gov (United States)

    Kim, Paul J; Attinger, Christopher E; Steinberg, John S; Evans, Karen K; Lehner, Burkhard; Willy, Christian; Lavery, Larry; Wolvos, Tom; Orgill, Dennis; Ennis, William; Lantis, John; Gabriel, Allen; Schultz, Gregory

    2013-12-01

    Negative-pressure wound therapy with instillation is increasingly utilized as an adjunct therapy for a wide variety of wounds. Despite its growing popularity, there is a paucity of evidence and lack of guidance to provide effective use of this therapy. A panel of experts was convened to provide guidance regarding the appropriate use of negative-pressure wound therapy with instillation. A face-to-face meeting was held where the available evidence was discussed and individual clinical experience with this therapy was shared. Follow-up communication among the panelists continued until consensus was achieved. The final consensus recommendations were derived through more than 80 percent agreement among the panelists. Nine consensus statements were generated that address the appropriate use of negative-pressure wound therapy with instillation. The question of clinical effectiveness of this therapy was not directly addressed by the consensus panel. This document serves as preliminary guidelines until more robust evidence emerges that will support or modify these consensus recommendations.

  3. Perceived social pressure not to experience negative emotion is linked to selective attention for negative information.

    Science.gov (United States)

    Bastian, Brock; Pe, Madeline Lee; Kuppens, Peter

    2017-02-01

    Social norms and values may be important predictors of how people engage with and regulate their negative emotional experiences. Previous research has shown that social expectancies (the perceived social pressure not to feel negative emotion (NE)) exacerbate feelings of sadness. In the current research, we examined whether social expectancies may be linked to how people process emotional information. Using a modified classical flanker task involving emotional rather than non-emotional stimuli, we found that, for those who experienced low levels of NE, social expectancies were linked to the selective avoidance of negative emotional information. Those who experienced high levels of NE did not show a selective avoidance of negative emotional information. The findings suggest that, for people who experience many NEs, social expectancies may lead to discrepancies between how they think they ought to feel and the kind of emotional information they pay attention to.

  4. Compensation for the Effects of Ambient Conditions on the Calibration of Multi-Capillary Pressure Drop Standards

    Directory of Open Access Journals (Sweden)

    Colard S

    2014-12-01

    Full Text Available Cigarette draw resistance and filter pressure drop (PD are both major physical parameters for the tobacco industry. Therefore these parameters must be measured reliably. For these measurements, specific equipment calibrated with PD transfer standards is used. Each transfer standard must have a known and stable PD value, such standards usually being composed of several capillary tubes associated in parallel. However, PD values are modified by ambient conditions during calibration of such standards, i.e. by temperature and relative humidity (RH of air, and atmospheric pressure. In order to reduce the influence of these ambient factors, a simplified model was developed for compensating the effects of ambient conditions on the calibration of multi-capillary PD standards.

  5. Accurate relations between pore size and the pressure of capillary condensation and the evaporation of nitrogen in cylindrical pores.

    Science.gov (United States)

    Morishige, Kunimitsu; Tateishi, Masayoshi

    2006-04-25

    To examine the theoretical and semiempirical relations between pore size and the pressure of capillary condensation or evaporation proposed so far, we constructed an accurate relation between the pore radius and the capillary condensation and evaporation pressure of nitrogen at 77 K for the cylindrical pores of the ordered mesoporous MCM-41 and SBA-15 silicas. Here, the pore size was determined from a comparison between the experimental and calculated X-ray diffraction patterns due to X-ray structural modeling recently developed. Among the many theoretical relations that differ from each other in the degree of theoretical improvements, a macroscopic thermodynamic approach based on Broekhoff-de Boer equations was found to be in fair agreement with the experimental relation obtained in the present study.

  6. The effect of a microscale fracture on dynamic capillary pressure of two-phase flow in porous media

    Science.gov (United States)

    Tang, Mingming; Lu, Shuangfang; Zhan, Hongbin; Wenqjie, Guo; Ma, Huifang

    2018-03-01

    Dynamic capillary pressure (DCP) effects, which is vital for predicting multiphase flow behavior in porous media, refers to the injection rate dependence capillary pressure observed during non-equilibrium displacement experiments. However, a clear picture of the effects of microscale fractures on DCP remains elusive. This study quantified the effects of microscale fractures on DCP and simulated pore-scale force and saturation change in fractured porous media using the multiphase lattice Boltzmann method (LBM). Eighteen simulation cases were carried out to calculate DCP as a function of wetting phase saturation. The effects of viscosity ratio and fracture orientation, aperture and length on DCP and DCP coefficient τ were investigated, where τ refers to the ratio of the difference of DCP and static capillary pressure (SCP) over the rate of wetting-phase saturation change versus time. Significant differences in τ values were observed between unfractured and fractured porous media. The τ values of fractured porous media were 1.1  × 104 Pa ms to 5.68 × 105 Pa ms, which were one or two orders of magnitude lower than those of unfractured porous media with a value of 4 × 106 Pa. ms. A horizontal fracture had greater effects on DCP and τ than a vertical fracture, given the same fracture aperture and length. This study suggested that a microscale fracture might result in large magnitude changes in DCP for two-phase flow.

  7. A Zero Dimensional Time-Dependent Model of High-Pressure Ablative Capillary Discharge (Preprint)

    National Research Council Canada - National Science Library

    Pekker, Leonid

    2008-01-01

    ... plasma core and the ablative capillary walls. The model includes the thermodynamics of partially ionized plasmas and non-ideal effects taking place in the high density plasma and assumes local thermodynamic equilibrium (LTE...

  8. An anesthetic management of negative pressure pulmonary edema

    Directory of Open Access Journals (Sweden)

    Dipti Raj

    2016-01-01

    Full Text Available Negative pressure pulmonary edema (NPPE is one of the common complications of upper airway obstruction seen by anesthesiologist during either in induction or emergence sometimes both. Patients who have experienced NPPE are generally healthy without comorbidities. NPPE is a result of marked decrease in intrathoracic pressure caused by ventilator efforts against a closed glottis resulting in disruption of normal intravascular Starling mechanism, leading to transudation of intravascular protein, and fluids into the pulmonary interstitium. The onset of NPPE is usually rapid and without prompt recognition and intervention, the outcome can be fatal. This case report is of a 40-year-old female adult, who underwent right-sided percutaneous nephrolithotomy for stone in the right kidney otherwise uncomplicated surgical procedure.

  9. Negative pressure therapy for the treatment of complex wounds

    Directory of Open Access Journals (Sweden)

    RENAN VICTOR KÜMPEL SCHMIDT LIMA

    Full Text Available ABSTRACT The objective of this study is to evaluate the effectiveness of negative pressure therapy (NPT in the treatment of complex wounds, with emphasis on its mechanisms of action and main therapeutic indications. We searched the Pubmed / Medline database for articles published from 1997 to 2016, and selected the most relevant ones. The mechanisms of action of NPT involveboth physical effects, such as increased perfusion, control of edema and exudate, reduction of wound dimensions and bacterial clearance, and biological ones, such as the stimulation of granulation tissue formation, microdeformations and reduction of Inflammatory response. The main indications of NPT are complex wounds, such as pressure ulcers, traumatic wounds, operative wound dehiscences, burns, necrotizing wounds, venous ulcers, diabetic wounds, skin grafts, open abdomen, prevention of complications in closed incisions and in the association with instillation of solutions in infected wounds.

  10. Study on the hydrogen negative ion in low pressure discharges

    International Nuclear Information System (INIS)

    Bruneteau, A.M.

    1983-07-01

    A new use of negative hydrogen ions is the production of intense fast neutral atom beams useful in plasma heating in thermonuclear heating. That is one of the reasons that started this study. The density of negative hydrogen ions in diffusion, and multipole-type low pressure (10 -3 - 10-2 Torr) discharges is deduced from the various formation and destruction processes of the species present in these discharges. The H - ions are essentially produced by dissociative attachment to vibrationally excited molecules and destroyed by processes the relative importance of which is discussed as a function of the discharge parameters. The experimental study of the density of the H - ions, measured by photodetachment, as a function of these parameters, coroborates the theoretical model [fr

  11. Dynamic isolation technologies in negative pressure isolation wards

    CERN Document Server

    Xu, Zhonglin

    2017-01-01

    This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.

  12. Numerical investigations of two-phase flow with dynamic capillary pressure in porous media via a moving mesh method

    Science.gov (United States)

    Zhang, Hong; Zegeling, Paul Andries

    2017-09-01

    Motivated by observations of saturation overshoot, this paper investigates numerical modeling of two-phase flow in porous media incorporating dynamic capillary pressure. The effects of the dynamic capillary coefficient, the infiltrating flux rate and the initial and boundary values are systematically studied using a traveling wave ansatz and efficient numerical methods. The traveling wave solutions may exhibit monotonic, non-monotonic or plateau-shaped behavior. Special attention is paid to the non-monotonic profiles. The traveling wave results are confirmed by numerically solving the partial differential equation using an accurate adaptive moving mesh solver. Comparisons between the computed solutions using the Brooks-Corey model and the laboratory measurements of saturation overshoot verify the effectiveness of our approach.

  13. Management of Pharyngocutaneous Fistula With Negative-Pressure Wound Therapy.

    Science.gov (United States)

    Teixeira, Sérgio; Costa, Joana; Bartosch, Isabel; Correia, Bernardo; Silva, Álvaro

    2017-06-01

    Pharyngocutaneous fistula is a common complication of laryngopharyngeal surgery and is associated with increased morbidity and mortality. Beyond the classical management, negative-pressure wound therapy (NPWT) can be an alternative and effective treatment. Two patients with pT3N0M0 squamous cell carcinoma of pyriform sinus were subjected to total laryngectomy and pharyngoesophageal reconstruction of a circular (patient 1) and an anterior wall defect (patient 2) with radial forearm free flap and pectoralis major muscle flap, respectively. Both developed a pharyngocutaneous fistula and NPWT was used.A significant decrease of the fistula aperture and exudate was observed after 22 and 21 days of NPWT in patients 1 and 2, respectively. After that standard wound care was instituted and closure of the fistulae was accomplished in 5 and 7 days, respectively. Negative-pressure wound therapy can be an effective treatment for pharyngocutaneous fistula closure, either in the setting of fistulae that persist besides multiple surgical revisions using muscle flaps or as a first-line therapy when fistulae develops.

  14. Solvation pressure as real pressure: I. Ethanol and starch under negative pressure

    CERN Document Server

    Uden, N W A V; Faux, D A; Tanczos, A C; Howlin, B; Dunstan, D J

    2003-01-01

    The reality of the solvation pressure generated by the cohesive energy density of liquids is demonstrated by three methods. Firstly, the Raman spectrum of ethanol as a function of cohesive energy density (solvation pressure) in ethanol-water and ethanol-chloroform mixtures is compared with the Raman spectrum of pure ethanol under external hydrostatic pressure and the solvation pressure and hydrostatic pressure are found to be equivalent for some transitions. Secondly, the bond lengths of ethanol are calculated by molecular dynamics modelling for liquid ethanol under pressure and for ethanol vapour. The difference in bond lengths between vapour and liquid are found to be equivalent to the solvation pressure for the C-H sub 3 , C-H sub 2 and O-H bond lengths, with discrepancies for the C-C and C-O bond lengths. Thirdly, the pressure-induced gelation of potato starch is measured in pure water and in mixtures of water and ethanol. The phase transition pressure varies in accordance with the change in solvation pre...

  15. Flow rate control in pressure-programmed capillary supercritical fluid chromatography

    NARCIS (Netherlands)

    Janssen, J.G.M.; Rijks, J.A.; Cramers, C.A.M.G.

    1990-01-01

    A versatile and simple system is described that allows variation of the column flow rate in open-tubular capillary supercritical fluid chromatography using both on-column and postcolumn detection. The system is based on column-effluent splitting in a low-dead-volume T piece at the column exit just

  16. Physical fitness and cardiovascular response to lower body negative pressure

    Science.gov (United States)

    Raven, P. B.; Rohm-Young, D.; Blomqvist, C. G.

    1984-01-01

    Klein et al. (1977) have questioned the concept of endurance training as an appropriate means of preparing for prolonged space flights. Their opinion was mainly based on reports of endurance athletes who had a decreased tolerance to orthostatic or gravitational stress induced by lower body negative pressure (LBNP), upright tilt, or whole body water immersion. The present investigation had the objective to determine if the hemodynamic response to LBNP is different between a high and average fit group of subjects. In addition, the discrete aspect of cardiovascular function which had been altered by chronic training was to be identified. On the basis of the results of experiments conducted with 14 young male volunteers, it is concluded that the reflex response to central hypovolemia is altered by endurance exercise training.

  17. Homogeneous nucleation in liquid nitrogen at negative pressures

    Energy Technology Data Exchange (ETDEWEB)

    Baidakov, V. G., E-mail: baidakov@itp.uran.ru; Vinogradov, V. E.; Pavlov, P. A. [Russian Academy of Sciences, Institute of Thermal Physics, Ural Branch (Russian Federation)

    2016-10-15

    The kinetics of spontaneous cavitation in liquid nitrogen at positive and negative pressures has been studied in a tension wave formed by a compression pulse reflected from the liquid–vapor interface on a thin platinum wire heated by a current pulse. The limiting tensile stresses (Δp = p{sub s}–p, where p{sub s} is the saturation pressure), the corresponding bubble nucleation frequencies J (10{sup 20}–10{sup 22} s{sup –1} m{sup –3}), and temperature induced nucleation frequency growth rate G{sub T} = dlnJ/dT have been experimentally determined. At T = 90 K, the limiting tensile stress was Δp = 8.3 MPa, which was 4.9 MPa lower than the value corresponding to the boundary of thermodynamic stability of the liquid phase (spinodal). The measurement results were compared to classical (homogeneous) nucleation theory (CNT) with and without neglect of the dependence of the surface tension of critical bubbles on their dimensions. In the latter case, the properties of new phase nuclei were described in terms of the Van der Waals theory of capillarity. The experimental data agree well with the CNT theory when it takes into account the “size effect.”.

  18. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    Science.gov (United States)

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Incisional Negative Pressure Wound Therapy in High Risk Patients Undergoing Panniculectomy: A Prospective Randomized Controlled Trial

    Science.gov (United States)

    2018-01-16

    Complications Wounds; Negative Pressure Wound Therapy; Wound Healing Delayed; Incisional; Panniculectomy; Incisional Negative Pressure Wound Therapy; Incisional Vac; Wound Vac; Obese; Renal Failure; Kidney Transplant; Complications; Wound Healing Complication

  20. The partitioning of nanoparticles to endothelium or interstitium during ultrasound-microbubble-targeted delivery depends on peak-negative pressure

    International Nuclear Information System (INIS)

    Hsiang, Y.-H.; Song, J.; Price, R. J.

    2015-01-01

    Patients diagnosed with advanced peripheral arterial disease often face poor prognoses and have limited treatment options. For some patient populations, the therapeutic growth of collateral arteries (i.e. arteriogenesis) that bypass regions affected by vascular disease may become a viable treatment option. Our group and others are developing therapeutic approaches centered on the ability of ultrasound-activated microbubbles to permeabilize skeletal muscle capillaries and facilitate the targeted delivery of pro-arteriogenic growth factor-bearing nanoparticles. The development of such approaches would benefit significantly from a better understanding of how nanoparticle diameter and ultrasound peak-negative pressure affect both total nanoparticle delivery and the partitioning of nanoparticles to endothelial or interstitial compartments. Toward this goal, using Balb/C mice that had undergone unilateral femoral artery ligation, we intra-arterially co-injected nanoparticles (50 and 100 nm) with microbubbles, applied 1 MHz ultrasound to the gracilis adductor muscle at peak-negative pressures of 0.7, 0.55, 0.4, and 0.2 MPa, and analyzed nanoparticle delivery and distribution. As expected, total nanoparticle (50 and 100 nm) delivery increased with increasing peak-negative pressure, with 50 nm nanoparticles exhibiting greater tissue coverage than 100 nm nanoparticles. Of particular interest, increasing peak-negative pressure resulted in increased delivery to the interstitium for both nanoparticle sizes, but had little influence on nanoparticle delivery to the endothelium. Thus, we conclude that alterations to peak-negative pressure may be used to adjust the fraction of nanoparticles delivered to the interstitial compartment. This information will be useful when designing ultrasound protocols for delivering pro-arteriogenic nanoparticles to skeletal muscle

  1. The partitioning of nanoparticles to endothelium or interstitium during ultrasound-microbubble-targeted delivery depends on peak-negative pressure

    Energy Technology Data Exchange (ETDEWEB)

    Hsiang, Y.-H.; Song, J.; Price, R. J., E-mail: rprice@virginia.edu [University of Virginia, Department of Biomedical Engineering (United States)

    2015-08-15

    Patients diagnosed with advanced peripheral arterial disease often face poor prognoses and have limited treatment options. For some patient populations, the therapeutic growth of collateral arteries (i.e. arteriogenesis) that bypass regions affected by vascular disease may become a viable treatment option. Our group and others are developing therapeutic approaches centered on the ability of ultrasound-activated microbubbles to permeabilize skeletal muscle capillaries and facilitate the targeted delivery of pro-arteriogenic growth factor-bearing nanoparticles. The development of such approaches would benefit significantly from a better understanding of how nanoparticle diameter and ultrasound peak-negative pressure affect both total nanoparticle delivery and the partitioning of nanoparticles to endothelial or interstitial compartments. Toward this goal, using Balb/C mice that had undergone unilateral femoral artery ligation, we intra-arterially co-injected nanoparticles (50 and 100 nm) with microbubbles, applied 1 MHz ultrasound to the gracilis adductor muscle at peak-negative pressures of 0.7, 0.55, 0.4, and 0.2 MPa, and analyzed nanoparticle delivery and distribution. As expected, total nanoparticle (50 and 100 nm) delivery increased with increasing peak-negative pressure, with 50 nm nanoparticles exhibiting greater tissue coverage than 100 nm nanoparticles. Of particular interest, increasing peak-negative pressure resulted in increased delivery to the interstitium for both nanoparticle sizes, but had little influence on nanoparticle delivery to the endothelium. Thus, we conclude that alterations to peak-negative pressure may be used to adjust the fraction of nanoparticles delivered to the interstitial compartment. This information will be useful when designing ultrasound protocols for delivering pro-arteriogenic nanoparticles to skeletal muscle.

  2. Determination of acid dissociation constants of triazole fungicides by pressure assisted capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Konášová, Renáta; Jaklová Dytrtová, Jana; Kašička, Václav

    2015-01-01

    Roč. 1408, Aug 21 (2015), s. 243-249 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA13-17224S; GA ČR GP13-21409P Institutional support: RVO:61388963 Keywords : triazole fungicides * acid dissociation constant * pK(a) * capillary electrophoresis * ionic mobility Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 3.926, year: 2015

  3. A lattice Boltzmann investigation of steady-state fluid distribution, capillary pressure and relative permeability of a porous medium: Effects of fluid and geometrical properties

    Science.gov (United States)

    Li, Zi; Galindo-Torres, Sergio; Yan, Guanxi; Scheuermann, Alexander; Li, Ling

    2018-06-01

    Simulations of simultaneous steady-state two-phase flow in the capillary force-dominated regime were conducted using the state-of-the-art Shan-Chen multi-component lattice Boltzmann model (SCMC-LBM) based on two-dimensional porous media. We focused on analyzing the fluid distribution (i.e., WP fluid-solid, NP fluid-solid and fluid-fluid interfacial areas) as well as the capillary pressure versus saturation curve which was affected by fluid and geometrical properties (i.e., wettability, adhesive strength, pore size distribution and specific surface area). How these properties influenced the relative permeability versus saturation relation through apparent effective permeability and threshold pressure gradient was also explored. The SCMC-LBM simulations showed that, a thin WP fluid film formed around the solid surface due to the adhesive fluid-solid interaction, resulting in discrete WP fluid distributions and reduction of the WP fluid mobility. Also, the adhesive interaction provided another source of capillary pressure in addition to capillary force, which, however, did not affect the mobility of the NP fluid. The film fluid effect could be enhanced by large adhesive strength and fine pores in heterogeneous porous media. In the steady-state infiltration, not only the NP fluid but also the WP fluid were subjected to the capillary resistance. The capillary pressure effect could be alleviated by decreased wettability, large average pore radius and improved fluid connectivity in heterogeneous porous media. The present work based on the SCMC-LBM investigations elucidated the role of film fluid as well as capillary pressure in the two-phase flow system. The findings have implications for ways to improve the macroscopic flow equation based on balance of force for the steady-state infiltration.

  4. Use of ion-pairing reagent for improving iodine speciation analysis in seaweed by pressure-driven capillary electrophoresis and ultraviolet detection.

    Science.gov (United States)

    Sun, Jiannan; Wang, Dan; Cheng, Heyong; Liu, Jinhua; Wang, Yuanchao; Xu, Zigang

    2015-01-30

    This study achieved resolution improvement for iodine speciation in the presence of an ion-pairing reagent by a pressure-driven capillary electrophoresis (CE) system. Addition of 0.01mM tetrabutyl ammonium hydroxide (TBAH) as the ion-pairing reagent into the electrophoretic buffer resulted in the complete separation of four iodine species (I(-), IO3(-), mono-iodothyrosine-MIT and di-iodothyrosine-DIT), because of the electrostatic interaction between TBAH and the negatively charged analytes. A +16kV separation voltage was applied along the separation capillary (50μm i.d., 80cm total and 60cm effective) with the inlet grounded. The detection wavelength was fixed at 210nm, and the pressure-driven flow rate was set at 0.12mLmin(-1) with an injected volume of 2μL. The optimal electrolyte consisted of 2mM borate, 2mM TBAH and 80% methanol with pH adjusted to 8.5. Baseline separation of iodine species was achieved within 7min. The detection limits for I(-), IO3(-), MIT and DIT were 0.052, 0.040, 0.032 and 0.025mgL(-1), respectively. The relative standard deviations of peak heights and areas were all below 3% for 5mgL(-1) and 5% for 1mgL(-1). Application of the proposed method was demonstrated by speciation analysis of iodine in two seaweed samples. The developed method offered satisfactory recoveries in the 91-99% range and good precisions (iodine speciation in environmental, food and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Negative pressure wound therapy for partial-thickness burns.

    Science.gov (United States)

    Dumville, Jo C; Munson, Christopher; Christie, Janice

    2014-12-15

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. We searched the Cochrane Wounds Group Specialised Register (searched 04 September 2014); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  6. Negative pressure wound therapy in patients with diabetic foot.

    Science.gov (United States)

    Ulusal, Ali Engin; Sahin, M Sükrü; Ulusal, Betül; Cakmak, Gökhan; Tuncay, Cengiz

    2011-01-01

    In this study our aim was to compare the results of standard dressing treatment to negative pressure wound therapy (NPWT) performed with a vacuum-assisted closure (VAC) device in patients with diabetic foot ulcers. We assessed the results of 35 patients treated for diabetic foot ulcer between 2006 and 2008. Of these cases, 20 (4 women and 16 men; mean age: 66 years; range: 52-90 years) were treated with standard wet dressings and 16 feet in 15 patients (10 men, 5 women; mean age: 58.9 years; range: 42-83 years) with VAC therapy. The success of treatment was evaluated in terms of hospitalization length and rate of limb salvation. The average hospitalization period with VAC treatment was 32 days compared to 59 days with standard dressing treatment. All patients treated with standard dressings eventually had to undergo amputation. However, the amputation rate was 37% in the VAC treated group and 88% of patients had a functional extremity at the end of treatment. VAC therapy, together with debridement and appropriate antibiotic therapy, enables a higher rate of limb salvage, especially in Wagner Grade 3 and Grade 4 ulcers.

  7. An experimental study of relative permeability hysteresis, capillary trapping characteristics, and capillary pressure of CO2/brine systems at reservoir conditions

    Science.gov (United States)

    Akbarabadi, Morteza

    We present the results of an extensive experimental study on the effects of hysteresis on permanent capillary trapping and relative permeability of CO2/brine and supercritical (sc)CO2+SO2/brine systems. We performed numerous unsteady- and steady-state drainage and imbibition full-recirculation flow experiments in three different sandstone rock samples, i.e., low and high-permeability Berea, Nugget sandstones, and Madison limestone carbonate rock sample. A state-of-the-art reservoir conditions core-flooding system was used to perform the tests. The core-flooding apparatus included a medical CT scanner to measure in-situ saturations. The scanner was rotated to the horizontal orientation allowing flow tests through vertically-placed core samples with about 3.8 cm diameter and 15 cm length. Both scCO2 /brine and gaseous CO2 (gCO2)/brine fluid systems were studied. The gaseous and supercritical CO2/brine experiments were carried out at 3.46 and 11 MPa back pressures and 20 and 55°C temperatures, respectively. Under the above-mentioned conditions, the gCO2 and scCO2 have 0.081 and 0.393 gr/cm3 densities, respectively. During unsteady-state tests, the samples were first saturated with brine and then flooded with CO2 (drainage) at different maximum flow rates. The drainage process was then followed by a low flow rate (0.375 cm 3/min) imbibition until residual CO2 saturation was achieved. Wide flow rate ranges of 0.25 to 20 cm3/min for scCO2 and 0.125 to 120 cm3min for gCO2 were used to investigate the variation of initial brine saturation (Swi) with maximum CO2 flow rate and variation of trapped CO2 saturation (SCO2r) with Swi. For a given Swi, the trapped scCO2 saturation was less than that of gCO2 in the same sample. This was attributed to brine being less wetting in the presence of scCO2 than in the presence of gCO 2. During the steady-state experiments, after providing of fully-brine saturated core, scCO2 was injected along with brine to find the drainage curve and as

  8. [Clinical analysis of 4 children with negative pressure pulmonary edema].

    Science.gov (United States)

    Chen, Jiehua; Wang, Shu; Ma, Hongling; Wang, Wenjian; Fu, Dan; Huang, Wenxian; Deng, Jikui; Tang, Huiying; He, Yanxia; Zheng, Yuejie

    2014-02-01

    To analyze the clinical characteristics of negative pressure pulmonary edema (NPPE). A retrospective investigation of the clinical manifestation, imageology, clinical course and outcome of 4 children with NPPE seen between June 2012 and July 2013 in a children's hospital. The causation of the airway obstruction was also explored. All the 4 cases were boys, the range of age was 40 days to 9 years. They had no history of respiratory and circulatory system disease. In 3 cases the disease had a sudden onset after the obstruction of airway, and in one the onset occurred 1.5 hours after removing the airway foreign body. All these cases presented with tachypnea, dyspnea, and cyanosis, none had fever. Three cases had coarse rales. Chest radiography was performed in 3 cases and CT scan was performed in 1 case, in all of them both lungs displayed diffuse ground-glass-like change and patchy consolidative infiltrates. Three cases were admitted to the ICU, duration of mechanical ventilation was less than 24 hours in 2 cases and 39 hours in one. Oxygen was given by mask to the remaining one in emergency department, whose symptoms were obviously improved in 10 hours. None was treated with diuretics, glucocorticoids or inotropic agents. Chest radiographs were taken within 24 hours of treatment in 2 cases and 24-48 hours in the other 2; almost all the pulmonary infiltrates were resolved. All the 4 cases were cured. The causes of airway obstruction were airway foreign bodies in two cases, laryngospasm in one and laryngomalacia in the other. NPPE is a life-threatening emergency, which is manifested by rapid onset of respiratory distress rapidly (usually in several minutes, but might be hours later) after relief of the airway obstruction, with findings of pulmonary edema in chest radiograph. The symptoms resolve rapidly by oxygen therapy timely with or without mechanical ventilation. In children with airway obstruction, NPPE should be considered.

  9. Investigation of atmospheric pressure capillary non-thermal plasmas and their applications to the degradation of volatile organic compounds

    Science.gov (United States)

    Yin, Shu-Min

    Atmospheric pressure capillary non-thermal plasma (AP-CNTP) has been investigated as a potential technology far the removal of volatile organic compounds (VOCs) in Advanced Life Support Systems (ALS). AP-CNTP is a destructive technology far the removal of VOCs from air streams by active plasma species, such as electrons, ions, and excited molecules. Complete VOC destruction ideally results in the formation of water, carbon dioxide (CO2), and other by-product's may also form, including ozone (O3), nitrous oxide (N2O), nitrogen dioxide (NO2), and decomposed hydrocarbons. Several organic compounds, such as BTEX, ethylene, n-heptane, isooctane, methanol and NH3, were tested in an AP-CNTP system. Parametric experiments were carried out by varying plasma discharge power, flowrates, and initial concentrations. The degradation efficiency varied depending on the chemical nature of the compounds. A plasmochemical kinetic model was derived for toluene, ethylbenzene, and m-xylene and n-heptane.

  10. New concept to describe three-phase capillary pressure-degree of saturation relationship in porous media.

    Science.gov (United States)

    Nakamura, Keita; Kikumoto, Mamoru

    2018-03-15

    The Leverett concept is used conventionally to model the relationship between the capillary pressures and the degrees of saturation in the water-nonaqueous phase liquid (NAPL)-air three-phase system in porous media. In this paper, the limitation of the Leverett concept that the concept is not applicable in the case of nonspreading NAPLs is discussed through microscopic consideration. A new concept that can be applied in the case of nonspreading NAPLs as well as spreading NAPLs is then proposed. The validity of the proposed concept is confirmed by comparing with past experimental data and simulation results obtained using the conventional model based on the Leverett concept. It is confirmed that the proposed concept can correctly predict the observed distributions of NAPLs, including those of nonspreading ones. Copyright © 2018. Published by Elsevier B.V.

  11. Pulmonary capillary wedge pressure, as inferred from lung areas in gated blood-pool scintigrams: concise communication

    International Nuclear Information System (INIS)

    Urbina, A.; Okada, R.D.; Palacios, I.; Osbakken, M.; Strauss, H.W.

    1981-01-01

    To determine whether the apex-to-base distribution of pulmonary blood volume, as obtained from gated cardiac blood-pool scans, could be used as a noninvasive method to estimate mean pulmonary capillary wedge pressure (PCWP), gated blood-pool scans were analyzed in 77 patients who also had PCWP measurements at cardiac catheterization. Ten of these patients had gated cardiac blood-pool scans and PCWP measurements both at rest and during exercise. The apex-to-base distribution of pulmonary blood volume was determined from the end-systolic frame of the left anterior oblique view by placing equal-sized regions of interest over the apex and base of the right lung. The ratio of apex counts over base counts (A/B ratio) was considered abnormal if greater than unity. The mean A/B ratio was 1.15 +/- 0.27 (1 s.d.) for the 32 studies associated with an abnormal mean PCWP (greater than 12 mm Hg). The mean A/B ratio was 0.85 +/- 0.23 for the 55 studies associated with a normal mean PCWP (p less than 0.01 comparing normal group with abnormal). The sensitivity of the A/B ratio for a mean PCWP greater than 12 mm Hg was 81%R (26/32). The specificity of the A/B ratio for a mean PCWP greater than or equal to 12 mm Hg was 89% (49/55). Thus, noninvasive determination of the pulmonary apex-to-base ratio from gated cardiac blood-pool scans appears to differentiate subjects with normal and abnormal mean pulmonary capillary wedge pressures

  12. Analysis of Critical Permeabilty, Capillary Pressure and Electrical Properties for Mesaverde Tight Gas Sandstones from Western U.S. Basins

    Energy Technology Data Exchange (ETDEWEB)

    Alan Byrnes; Robert Cluff; John Webb; John Victorine; Ken Stalder; Daniel Osburn; Andrew Knoderer; Owen Metheny; Troy Hommertzheim; Joshua Byrnes; Daniel Krygowski; Stefani Whittaker

    2008-06-30

    Although prediction of future natural gas supply is complicated by uncertainty in such variables as demand, liquefied natural gas supply price and availability, coalbed methane and gas shale development rate, and pipeline availability, all U.S. Energy Information Administration gas supply estimates to date have predicted that Unconventional gas sources will be the dominant source of U.S. natural gas supply for at least the next two decades (Fig. 1.1; the period of estimation). Among the Unconventional gas supply sources, Tight Gas Sandstones (TGS) will represent 50-70% of the Unconventional gas supply in this time period (Fig. 1.2). Rocky Mountain TGS are estimated to be approximately 70% of the total TGS resource base (USEIA, 2005) and the Mesaverde Group (Mesaverde) sandstones represent the principal gas productive sandstone unit in the largest Western U.S. TGS basins including the basins that are the focus of this study (Washakie, Uinta, Piceance, northern Greater Green River, Wind River, Powder River). Industry assessment of the regional gas resource, projection of future gas supply, and exploration programs require an understanding of reservoir properties and accurate tools for formation evaluation. The goal of this study is to provide petrophysical formation evaluation tools related to relative permeability, capillary pressure, electrical properties and algorithms for wireline log analysis. Detailed and accurate moveable gas-in-place resource assessment is most critical in marginal gas plays and there is need for quantitative tools for definition of limits on gas producibility due to technology and rock physics and for defining water saturation. The results of this study address fundamental questions concerning: (1) gas storage; (2) gas flow; (3) capillary pressure; (4) electrical properties; (5) facies and upscaling issues; (6) wireline log interpretation algorithms; and (7) providing a web-accessible database of advanced rock properties. The following text

  13. Multiscale Pore Throat Network Reconstruction of Tight Porous Media Constrained by Mercury Intrusion Capillary Pressure and Nuclear Magnetic Resonance Measurements

    Science.gov (United States)

    Xu, R.; Prodanovic, M.

    2017-12-01

    Due to the low porosity and permeability of tight porous media, hydrocarbon productivity strongly depends on the pore structure. Effective characterization of pore/throat sizes and reconstruction of their connectivity in tight porous media remains challenging. Having a representative pore throat network, however, is valuable for calculation of other petrophysical properties such as permeability, which is time-consuming and costly to obtain by experimental measurements. Due to a wide range of length scales encountered, a combination of experimental methods is usually required to obtain a comprehensive picture of the pore-body and pore-throat size distributions. In this work, we combine mercury intrusion capillary pressure (MICP) and nuclear magnetic resonance (NMR) measurements by percolation theory to derive pore-body size distribution, following the work by Daigle et al. (2015). However, in their work, the actual pore-throat sizes and the distribution of coordination numbers are not well-defined. To compensate for that, we build a 3D unstructured two-scale pore throat network model initialized by the measured porosity and the calculated pore-body size distributions, with a tunable pore-throat size and coordination number distribution, which we further determine by matching the capillary pressure vs. saturation curve from MICP measurement, based on the fact that the mercury intrusion process is controlled by both the pore/throat size distributions and the connectivity of the pore system. We validate our model by characterizing several core samples from tight Middle East carbonate, and use the network model to predict the apparent permeability of the samples under single phase fluid flow condition. Results show that the permeability we get is in reasonable agreement with the Coreval experimental measurements. The pore throat network we get can be used to further calculate relative permeability curves and simulate multiphase flow behavior, which will provide valuable

  14. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  15. Pressure-accelerated azide-alkyne cycloaddition : micro capillary versus autoclave reactor performance

    NARCIS (Netherlands)

    Borukhova, S.; Seeger, A.D.; Noël, T.; Wang, Q.; Busch, M.; Hessel, V.

    2015-01-01

    Pressure effects on regioselectivity and yield of cycloaddition reactions have been shown to exist. Nevertheless, high pressure synthetic applications with subsequent benefits in the production of natural products are limited by the general availability of the equipment. In addition, the virtues and

  16. Expression of HIF-1{alpha} in irradiated tissue is altered by topical negative-pressure therapy

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, A.; Stange, S.; Labanaris, A.; Horch, R.E. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Plastic and Hand Surgery; Dimmler, A. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Pathology; Sauer, R.; Grabenbauer, G. [Erlangen-Nuernberg Univ. (Germany). Dept. of Radiation Oncology

    2007-03-15

    Background and Purpose: Despite the enormous therapeutic potential of modern radiotherapy, common side effects such as radiation-induced wound healing disorders remain a well-known clinical phenomenon. Topical negative pressure therapy (TNP) is a novel tool to alleviate intraoperative, percutaneous irradiation or brachytherapy. Since TNP has been shown to positively influence the perfusion of chronic, poorly vascularized wounds, the authors applied this therapeutic method to irradiated wounds and investigated the effect on tissue oxygenation in irradiated tissue in five patients. Material and Methods: With informed patients' consent, samples prior to and 4 and 8 days after continuous TNP with -125 mmHg were obtained during routine wound debridements. Granulation tissue was stained with hematoxylin-eosin, and additionally with CD31, HIF-1{alpha} (hypoxia-inducible factor-1{alpha}), and D2-40 to detect blood vessels, measure indirect signs of hypoxia, and lymph vessel distribution within the pre- and post-TNP samples. Results: In this first series of experiments, a positive influence of TNP onto tissue oxygenation in radiation-induced wounds could be demonstrated. TNP led to a significant decrease of 53% HIF-1{alpha}-positive cell nuclei. At the same time, a slight reduction of CD31-stained capillaries was seen in comparison to samples before TNP. Immunostaining with D2-40 revealed an increased number of lymphatic vessels with distended lumina and an alteration of the parallel orientation within the post-TNP samples. Conclusion: This study is, to the authors' knowledge, the first report on a novel previously not described histological marker to demonstrate the effects of TNP on HIF-1{alpha} expression as an indirect marker of tissue oxygenation in irradiated wounds, as demonstrated by a reduction of HIF-1{alpha} concentration after TNP. Since this observation may be of significant value to develop possible new strategies to treat radiation-induced tissue

  17. Expression of HIF-1α in irradiated tissue is altered by topical negative-pressure therapy

    International Nuclear Information System (INIS)

    Grimm, A.; Stange, S.; Labanaris, A.; Horch, R.E.; Dimmler, A.; Sauer, R.; Grabenbauer, G.

    2007-01-01

    Background and Purpose: Despite the enormous therapeutic potential of modern radiotherapy, common side effects such as radiation-induced wound healing disorders remain a well-known clinical phenomenon. Topical negative pressure therapy (TNP) is a novel tool to alleviate intraoperative, percutaneous irradiation or brachytherapy. Since TNP has been shown to positively influence the perfusion of chronic, poorly vascularized wounds, the authors applied this therapeutic method to irradiated wounds and investigated the effect on tissue oxygenation in irradiated tissue in five patients. Material and Methods: With informed patients' consent, samples prior to and 4 and 8 days after continuous TNP with -125 mmHg were obtained during routine wound debridements. Granulation tissue was stained with hematoxylin-eosin, and additionally with CD31, HIF-1α (hypoxia-inducible factor-1α), and D2-40 to detect blood vessels, measure indirect signs of hypoxia, and lymph vessel distribution within the pre- and post-TNP samples. Results: In this first series of experiments, a positive influence of TNP onto tissue oxygenation in radiation-induced wounds could be demonstrated. TNP led to a significant decrease of 53% HIF-1α-positive cell nuclei. At the same time, a slight reduction of CD31-stained capillaries was seen in comparison to samples before TNP. Immunostaining with D2-40 revealed an increased number of lymphatic vessels with distended lumina and an alteration of the parallel orientation within the post-TNP samples. Conclusion: This study is, to the authors' knowledge, the first report on a novel previously not described histological marker to demonstrate the effects of TNP on HIF-1α expression as an indirect marker of tissue oxygenation in irradiated wounds, as demonstrated by a reduction of HIF-1α concentration after TNP. Since this observation may be of significant value to develop possible new strategies to treat radiation-induced tissue injury, further investigations of HIF

  18. A Comprehensive Review on Measurement and Correlation Development of Capillary Pressure for Two-Phase Modeling of Proton Exchange Membrane Fuel Cells

    Directory of Open Access Journals (Sweden)

    Chao Si

    2015-01-01

    Full Text Available Water transport and the corresponding water management strategy in proton exchange membrane (PEM fuel cells are quite critical for the improvement of the cell performance. Accuracy modeling of water transport in porous electrodes strongly depends on the appropriate constitutive relationship for capillary pressure which is referred to as pc-s correlation, where pc is the capillary pressure and s is the fraction of saturation in the pores. In the present PEM fuel cell two-phase models, the Leverett-Udell pc-s correlation is widely utilized which is proposed based on fitting the experimental data for packed sands. However, the size and structure of pores for the commercial porous electrodes used in PEM fuel cells differ from those for the packed sands significantly. As a result, the Leverett-Udell correlation should be improper to characterize the two-phase transport in the porous electrodes. In the recent decade, many efforts were devoted to measuring the capillary pressure data and developing new pc-s correlations. The objective of this review is to review the most significant developments in recent years concerning the capillary pressure measurements and the developed pc-s correlations. It is expected that this review will be beneficial to develop the improved PEM fuel cell two-phase model.

  19. Influence of Adsorption and Capillary Pressure on Phase Equilibria Inside Shale Reservoirs

    DEFF Research Database (Denmark)

    Sandoval, Diego R.; Yan, Wei; Michelsen, Michael L.

    2018-01-01

    is moderate in comparison to the that at low pressure and high temperature. The adsorption effects are stronger for the gas bulk phase region, leading to bigger changes in the gas phase composition and the shift of the dew point curve. PVT simulations of two model reservoir fluid systems show significant...... envelope is different. In general, a much shrunk phase envelope with a shifted critical point is observed. The heavier components are preferentially adsorbed in the whole pressure and temperature range studied here. At high pressure and low temperature, the selectivity towards heavier components...

  20. Role of Negative Pressure Wound Therapy in Healing of Diabetic ...

    African Journals Online (AJOL)

    Journal of Surgical Technique and Case Report | Jan-Jun 2011 | Vol-3 | Issue-1. 10. Role of Negative ... case of any difficulty faced in the application of VAC dressings. BLEEDING ISSUE ... show exposed bone, tendon, joint capsule or fascia.

  1. The therapeutic effect of negative pressure in treating femoral head necrosis in rabbits.

    Science.gov (United States)

    Zhang, Yin-gang; Wang, Xuezhi; Yang, Zhi; Zhang, Hong; Liu, Miao; Qiu, Yushen; Guo, Xiong

    2013-01-01

    Because negative pressure can stimulate vascular proliferation, improve blood circulation and promote osteogenic differentiation of bone marrow stromal cells, we investigated the therapeutic effect of negative pressure on femoral head necrosis (FHN) in a rabbit model. Animals were divided into four groups (n = 60/group): [1] model control, [2] core decompression, [3] negative pressure and [4] normal control groups. Histological investigation revealed that at 4 and 8 weeks postoperatively, improvements were observed in trabecular bone shape, empty lacunae and numbers of bone marrow hematopoietic cells and fat cells in the negative pressure group compared to the core decompression group. At week 8, there were no significant differences between the negative pressure and normal control groups. Immunohistochemistry staining revealed higher expression of vascular endothelial growth factor (VEGF) and bone morphogenetic protein-2 (BMP-2) in the femoral heads in the negative pressure group compared with the core decompression group. Transmission electron microscopy revealed that cell organelles were further developed in the negative pressure group compared with the core decompression group. Microvascular ink staining revealed an increased number of bone marrow ink-stained blood vessels, a thicker vascular lumen and increased microvascular density in the negative pressure group relative to the core decompression group. Real-time polymerase chain reaction revealed that expression levels of both VEGF and BMP-2 were higher in the negative pressure group compared with the core decompression group. In summary, negative pressure has a therapeutic effect on FHN. This effect is superior to core decompression, indicating that negative pressure is a potentially valuable method for treating early FHN.

  2. Experimental sizing and assessment of two-phase pressure drop correlations for a capillary tube with transcritical and subcritical carbon dioxide flow

    International Nuclear Information System (INIS)

    Trinchieri, R; Boccardi, G; Calabrese, N; Zummo, G; Celata, G P

    2014-01-01

    In the last years, CO 2 was proposed as an alternative refrigerant for different refrigeration applications (automotive air conditioning, heat pumps, refrigerant plants, etc.) In the case of low power refrigeration applications, as a household refrigerator, the use of too expensive components is not economically sustainable; therefore, even if the use of CO 2 as the refrigerant is desired, it is preferable to use conventional components as much as possible. For these reasons, the capillary tube is frequently proposed as expansion system. Then, it is necessary to characterize the capillary in terms of knowledge of the evolving mass flow rate and the associate pressure drop under all possible operative conditions. For this aim, an experimental campaign has been carried out on the ENEA test loop 'CADORE' to measure the performance of three capillary tubes having same inner diameter (0.55 mm) but different lengths (4, 6 and 8 meters). The test range of inlet pressure is between about 60 and 110 bar, whereas external temperatures are between about 20 to 42 °C. The two-phase pressure drop through the capillary tube is detected and experimental values are compared with the predictions obtained with the more widely used correlations available in the literature. Correlations have been tested over a wide range of variation of inlet flow conditions, as a function of different inlet parameters.

  3. The importance of capillary density-stroke work mismatch for right ventricular adaptation to chronic pressure overload.

    Science.gov (United States)

    Noly, Pierre-Emmanuel; Haddad, François; Arthur-Ataam, Jennifer; Langer, Nathaniel; Dorfmüller, Peter; Loisel, Fanny; Guihaire, Julien; Decante, Benoit; Lamrani, Lilia; Fadel, Elie; Mercier, Olaf

    2017-12-01

    Mechanisms of right ventricular (RV) adaptation to chronic pressure overload are not well understood. We hypothesized that a lower capillary density (CD) to stroke work ratio would be associated with more fibrosis and RV maladaptive remodeling. We induced RV chronic pressure overload over a 20-week period in 2 piglet models of pulmonary hypertension; that is, a shunt model (n = 5) and a chronic thromboembolic pulmonary hypertension model (n = 5). We assessed hemodynamic parameters and RV remodeling as well as RV CD, fibrosis, and angiogenic factors expression. Although RV was similarly hypertrophied in both models, maladapted RV remodeling with impaired systolic function was only seen in chronic thromboembolic pulmonary hypertension group members who had lower CD (484 ± 99 vs 1213 ± 74 cap/mm 2 ; P work ratio (0.29 ± 0.07 vs 0.82 ± 0.16; P = .02), higher myocardial fibrosis (15.4% ± 3.8% vs 8.0% ± 2.5%; P work ratio) was associated with greater degree of myocardial fibrosis and RV dysfunction and could be a promising index of RV maladaptation. Further studies are needed to understand the underlying mechanisms. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Multiphase Transport in Porous Media: Gas-Liquid Separation Using Capillary Pressure Gradients International Space Station (ISS) Flight Experiment Development

    Science.gov (United States)

    Wheeler, Richard R., Jr.; Holtsnider, John T.; Dahl, Roger W.; Deeks, Dalton; Javanovic, Goran N.; Parker, James M.; Ehlert, Jim

    2013-01-01

    Advances in the understanding of multiphase flow characteristics under variable gravity conditions will ultimately lead to improved and as of yet unknown process designs for advanced space missions. Such novel processes will be of paramount importance to the success of future manned space exploration as we venture into our solar system and beyond. In addition, because of the ubiquitous nature and vital importance of biological and environmental processes involving airwater mixtures, knowledge gained about fundamental interactions and the governing properties of these mixtures will clearly benefit the quality of life here on our home planet. The techniques addressed in the current research involving multiphase transport in porous media and gas-liquid phase separation using capillary pressure gradients are also a logical candidate for a future International Space Station (ISS) flight experiment. Importantly, the novel and potentially very accurate Lattice-Boltzmann (LB) modeling of multiphase transport in porous media developed in this work offers significantly improved predictions of real world fluid physics phenomena, thereby promoting advanced process designs for both space and terrestrial applications.This 3-year research effort has culminated in the design and testing of a zero-g demonstration prototype. Both the hydrophilic (glass) and hydrophobic (Teflon) media Capillary Pressure Gradient (CPG) cartridges prepared during the second years work were evaluated. Results obtained from ground testing at 1-g were compared to those obtained at reduced gravities spanning Martian (13-g), Lunar (16-g) and zero-g. These comparisons clearly demonstrate the relative strength of the CPG phenomena and the efficacy of its application to meet NASAs unique gas-liquid separation (GLS) requirements in non-terrestrial environments.LB modeling software, developed concurrently with the zero-g test effort, was shown to accurately reproduce observed CPG driven gas-liquid separation

  5. Dynamic Leg Exercise Improves Tolerance to Lower Body Negative Pressure

    Science.gov (United States)

    Watenpaugh, D. E.; Ballard, R. E.; Stout, M. S.; Murthy, G.; Whalen, R. T.; Hargens, A. R.

    1994-01-01

    These results clearly demonstrate that dynamic leg exercise against the footward force produced by LBNP substantially improves tolerance to LBNP, and that even cyclic ankle flexion without load bearing also increases tolerance. This exercise-induced increase of tolerance was actually an underestimate, because subjects who completed the tolerance test while exercising could have continued for longer periods. Exercise probably increases LBNP tolerance by multiple mechanisms. Tolerance was increased in part by skeletal muscle pumping venous blood from the legs. Rosenhamer and Linnarsson and Rosenhamer also deduced this for subjects cycling during centrifugation, although no measurements of leg volume were made in those studies: they found that male subjects cycling at 98 W could endure 3 Gz centrifugation longer than when they remained relaxed during centrifugation. Skeletal muscle pumping helps maintain cardiac filling pressure by opposing gravity-, centrifugation-, or LBNP-induced accumulation of blood and extravascular fluid in the legs.

  6. Pressurized capillary electrochromatographic analysis of water-soluble vitamins by combining with on-line concentration technique.

    Science.gov (United States)

    Jia, Li; Liu, Yaling; Du, Yanyan; Xing, Da

    2007-06-22

    A pressurized capillary electrochromatography (pCEC) system was developed for the separation of water-soluble vitamins, in which UV absorbance was used as the detection method and a monolithic silica-ODS column as the separation column. The parameters (type and content of organic solvent in the mobile phase, type and concentration of electrolyte, pH of the electrolyte buffer, applied voltage and flow rate) affecting the separation resolution were evaluated. The combination of two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, was utilized to improve detection sensitivity, which proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Coupling electrokinetic injection with the on-line concentration techniques was much more beneficial for the concentration of positively charged vitamins. Comparing with the conventional injection mode, the enhancement in the detection sensitivities of water-soluble vitamins using the on-line concentration technique is in the range of 3 to 35-fold. The developed pCEC method was applied to evaluate water-soluble vitamins in corns.

  7. Mechanisms of lower body negative pressure-induced syncope

    Science.gov (United States)

    Davrath, Linda Ruble

    Although extensively investigated, the mechanisms of post-spaceflight orthostatic intolerance have not been elucidated. The working hypothesis was that a markedly reduced left ventricular end-systolic volume (LVESV) would be achieved during progressive, presyncopal-limited LBNP and would cause bradycardia and a fall in blood pressure, thus triggering syncope. Eight healthy men, age 25.1 ± 1.3 years, volunteered for the study. Subjects were exposed to graded levels of LBNP on two separate occasions. Changes in left ventricular end-diastolic volume and LVESV were measured, using two-dimensional echocardiography, at each stage of LBNP from rest to presyncope. Plasma venous blood samples were withdrawn at the end of each stage of the LBNP protocol for the measurement of plasma venous catecholamines and plasma renin activity (PRA). Catecholamines were analyzed by HPLC with electro-chemical detection, and PRA was determined by radioimmunoassay. All subjects reached presyncope during the LBNP. LVESV decreased by 28% at presyncope with no evidence of ventricular cavity obliteration. Norepinephrine (NE) increased by 44% from rest to presyncope, but no epinephrine surge was detected (35% increase from rest to presyncope). These data indicate that it is possible to initiate syncope with only a 28% decrease in LVESV, and that sympatho-inhibition and bradycardia are not required elements for syncope to occur. To investigate the effect of moderate sodium restriction on cardiovascular hemodynamics and orthostatic tolerance, presyncopal LBNP testing was performed. Urinary sodium excretion was significantly higher on the normal-sodium diet when compared with the sodium-restricted diet, but urinary potassium was not different. Cumulative stress index (655 ± 460 on normal-sodium diet vs. 639 ± 388 on sodium-restricted diet) scores were not different. Cardiac volumes, blood pressure and total peripheral resistance were not different at any stage of the LBNP between the diets, nor

  8. Measurements of capillary pressure and electric permittivity of gas-water systems in porous media at elevated pressures : Application to geological storage of CO2 in aquifers and wetting behavior in coal

    NARCIS (Netherlands)

    Plug, W.J.

    2007-01-01

    Sequestration of CO2 in aquifers and coal layers is a promising technique to reduce greenhouse gas emissions. Considering the reservoir properties, e.g. wettability, heterogeneity and the caprocks sealing capacity, the capillary pressure is an important measure to evaluate the efficiency, the

  9. Negative-Pressure Hydrocephalus: A Case Report on Successful Treatment Under Intracranial Pressure Monitoring with Bilateral Ventriculoperitoneal Shunts.

    Science.gov (United States)

    Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming

    2017-03-01

    Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Treatment Experience of Continuous Negative Pressure Drainage in the Acute Anterior Mediastinal Infection of Oropharyngeal Origined

    Directory of Open Access Journals (Sweden)

    Anping CHEN

    2018-04-01

    Full Text Available Background and objective Mediastinal infection is a serious infection of mediastinal connective tissue, with more complications and higher mortality. Application of broad-spectrum antibiotics and nutritional support, early sufficient drainage is the key to successful treatment. In the mode of drainage, this paper discusses the application of continuous negative pressure drainage technique to treat acute anterior mediastinal infection of severe mouth pharynx source, and the good results are summarized and shared. Methods In January to December in 2017, a total of 17 cases treated acute mediastinal infection is derived from the throat, has formed a mediastinal abscess, surgery adopts retrosternal counterpart negative pressure drainage way, namely the sternum nest and free sternum xiphoid process under the incision on the first mediastinal clearance, make breakthrough and placed drainage device, suture closed wound, continuous negative pressure drainage, negative pressure using 3 cm-5 cm water column. Results Among the 17 patients, 14 patients were relieved by continuous negative pressure drainage, and then the drainage tube was removed. In 2 cases, the infection broke into the right thoracic cavity, and the closed drainage caused the negative pressure to disappear, and the negative pressure drainage was replaced by the conventional drainage, and the drainage tube was removed after the drainage tube was clear. One patient had formed a mediastinal abscess incision drainage time later, complicated with septic shock and sepsis, resulting in the death of multiple organ failure. Conclusion The traditional treatment of severe acute mediastinal infection is sternal incision and drainage. Continuous negative pressure drainage adequate drainage of mediastinal can relieve patients' pain, effusion, and avoid the dressing out repeatedly. It is an effective method. However, there are limitations in this method, which need to be further optimized.

  11. Negative Pressure Pulmonary Edema after Reversing Rocuronium-Induced Neuromuscular Blockade by Sugammadex

    Directory of Open Access Journals (Sweden)

    Manzo Suzuki

    2014-01-01

    Full Text Available Negative pressure pulmonary edema (NPPE is a rare complication that accompanies general anesthesia, especially after extubation. We experienced a case of negative pressure pulmonary edema after tracheal extubation following reversal of rocuronium-induced neuromuscular blockade by sugammadex. In this case, the contribution of residual muscular block on the upper airway muscle as well as large inspiratory forces created by the respiratory muscle which has a low response to muscle relaxants, is suspected as the cause.

  12. Empirical Formulas for Calculation of Negative Pressure Difference in Vacuum Pipelines

    Directory of Open Access Journals (Sweden)

    Marek Kalenik

    2015-10-01

    Full Text Available The paper presents the analysis of results of empirical investigations of a negative pressure difference in vacuum pipelines with internal diameters of 57, 81, 102 mm. The investigations were performed in an experimental installation of a vacuum sewage system, built in a laboratory hall on a scale of 1:1. The paper contains a review of the literature concerning two-phase flows (liquid-gas in horizontal, vertical and diagonal pipelines. It presents the construction and working principles of the experimental installation of vacuum sewage system in steady and unsteady conditions during a two-phase flow of water and air. It also presents a methodology for determination of formula for calculation of a negative pressure difference in vacuum pipelines. The results obtained from the measurements of the negative pressure difference Δpvr in the vacuum pipelines were analyzed and compared with the results of calculations of the negative pressure difference Δpvr, obtained from the determined formula. The values of the negative pressure difference Δpvr calculated for the vacuum pipelines with internal diameters of 57, 81, and 102 mm with the use of Formula (19 coincide with the values of Δpvr measured in the experimental installation of a vacuum sewage system. The dependence of the negative pressure difference Δpvr along the length of the vacuum pipelines on the set negative pressure in the vacuum container pvzp is linear. The smaller the vacuum pipeline diameter, the greater the negative pressure difference Δpvr is along its length.

  13. Management of High-Voltage Burns of the Hand and Wrist with Negative Pressure Dressing

    Directory of Open Access Journals (Sweden)

    Nazım Gümüş

    2017-12-01

    Full Text Available Objective: Negative pressure dressing stimulates wound healing by promoting cellular proliferation and regeneration. It also removes interstitial edema and increases local blood flow, resulting in rapid growth of the granulation tissue. We used the dressing method in deep hand and wrist burns caused by high-voltage electrical current, which leads to progressive tissue necrosis, elevated compartment pressure, and deep tissue edema, to reveal if subatmospheric pressure could limit the zone of injury or ongoing tissue necrosis after electrical burn. Material and Methods: Six hands of five patients, who came in contact with high-voltage electrical wire carrying more than 1000 volts, are presented in this study. Hands and wrists were seriously injured and contracted. After the initial treatment involving fluid resuscitation, fasciotomy, carpal tunnel release, and debridement, a negative pressure dressing was applied to the wounds of hand, wrist, and forearm with 125 mm Hg continuous pressure, and maintained for 20 days. Results: When negative pressure dressing was stopped on the 20th day, significant granulation tissue developed over the hand and forearm wounds. However, wrist wounds needed more debridement and repeated dressings because of the presence of necrosis. Edema of the hands subsided significantly during the use of negative pressure dressing. Time to closure for hand and forearm wounds decreased considerably. Moreover, in one wrist, spontaneous closure was achieved at about one month. All hands except one treated with negative pressure dressing could be saved from amputation; however, significant tissue loss developed, needing complex reconstruction procedures. One hand was amputated because of the permanent loss of blood perfusion. Conclusion: The management of high-voltage burns of hand and wrist with subatmospheric pressure appears to be capable of reducing hand edema and accelerating closure of the wounds. It seems that negative

  14. The effects of superimposed tilt and lower body negative pressure on anterior and posterior cerebral circulations

    OpenAIRE

    Tymko, Michael M.; Rickards, Caroline A.; Skow, Rachel J.; Ingram?Cotton, Nathan C.; Howatt, Michael K.; Day, Trevor A.

    2016-01-01

    Abstract Steady?state tilt has no effect on cerebrovascular reactivity to increases in the partial pressure of end?tidal carbon dioxide (PETCO 2). However, the anterior and posterior cerebral circulations may respond differently to a variety of stimuli that alter central blood volume, including lower body negative pressure (LBNP). Little is known about the superimposed effects of head?up tilt (HUT; decreased central blood volume and intracranial pressure) and head?down tilt (HDT; increased ce...

  15. Measurement of negative ion mobilities in O2 and O3 mixtures at atmospheric pressure

    International Nuclear Information System (INIS)

    Itoh, H.; Norimoto, K.; Hayashi, T.

    1998-01-01

    Mobility measurements of negative molecular oxygen ions in pure oxygen and in an oxygen-ozone mixture are reported. A cascaded gap consisting of an ion drift gap and an ion detection gap was used in the experiment. The ion detection gap was formed by a positive point and a grounded plane electrode was operated at atmospheric pressure. The zero field mobility of negative molecular oxygen ions was determined to be 2.07+-0.02 cm 2 /V.s. A somewhat higher value of oxygen mobility was found at higher electric field/pressure ratios; this is presumed to be due to negative ozone ions. When changing the electric field/pressure ratio the mobility of negative oxygen ions in oxygen-ozone mixtures becomes smaller than that in pure oxygen; this is probably due to the cumulative effect of other particles produced by silent discharges. (J.U.)

  16. Simultaneous determination of clebopride and a major metabolite N-desbenzylclebopride in plasma by capillary gas chromatography-negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Robinson, P R; Jones, M D; Maddock, J; Rees, L W

    1991-03-08

    A procedure for the simultaneous assay of clebopride and its major metabolite N-desbenzylclebopride in plasma has been developed. The method utilizes capillary gas chromatography-negative-ion chemical ionization mass spectrometry with selected-ion monitoring of characteristic ions. Employing 2-ethoxy analogues as internal standards, the benzamides were extracted from basified plasma using dichloromethane. Subsequent reaction with heptafluorobutyric anhydride produced volatile mono- and diheptafluorobutyryl derivatives of clebopride and N-desbenzylclebopride, respectively. The methane negative-ion mass spectra of these derivatives exhibited intense high-mass ions ideal for specific quantitation of low levels in biological fluids. Using this procedure the recovery of the drug and metabolite from human plasma was found to be 84.4 +/- 1.5% (n = 3) and 77.4 +/- 4.7% (n = 3), respectively, at 0.5 ng/ml. Measurement of both compounds down to 0.10 ng/ml with a coefficient of variation of less than 10.5% is described. Plasma levels are reported in four volunteers up to 24 h following oral administration of 1 mg of clebopride malate salt.

  17. The paradox of negative pressure wound therapy--in vitro studies.

    Science.gov (United States)

    Kairinos, Nicolas; Solomons, Michael; Hudson, Donald A

    2010-01-01

    Negative-pressure wound therapy (NPWT) has revolutionised wound care. Yet, it is still not understood how hypobaric tissue pressure accelerates wound healing. There is very little reported on the relevant physics of any substance subjected to suction in this manner. The common assumption is that applying suction to a substance is likely to result in a reduction of pressure in that substance. Although more than 250 research articles have been published on NPWT, there are little data verifying whether suction increases or decreases the pressure of the substance it is applied to. Clarifying this basic question of physics is the first step in understanding the mechanism of action of these dressings. In this study, pressure changes were recorded in soft plasticene and processed meat, using an intracranial tissue pressure microsensor. Circumferential, non-circumferential and cavity NPWT dressings were applied, and pressure changes within the underlying substance were recorded at different suction pressures. Pressures were also measured at 1cm, 2 cm and 3 cm from the NPWT placed in a cavity. In all three types of NPWT dressings, the underlying substance pressure was increased (hyperbaric) as suction pressure increased. Although there was a substantial pressure increase at 1cm, the rise in pressure at the 2-cm and 3-cm intervals was minimal. Substance pressure beneath all types of NPWT dressing is hyperbaric in inanimate substances. Higher suction pressures generate greater substance pressures; however, the increased pressure rapidly dissipates as the distance from the dressing is increased. The findings of this study on inanimate objects suggest that we may need to review our current perception of the physics underlying NPWT dressings. Further research of this type on living tissues is warranted. Copyright (c) 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    Science.gov (United States)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  19. A pressure-amplifying framework material with negative gas adsorption transitions.

    Science.gov (United States)

    Krause, Simon; Bon, Volodymyr; Senkovska, Irena; Stoeck, Ulrich; Wallacher, Dirk; Többens, Daniel M; Zander, Stefan; Pillai, Renjith S; Maurin, Guillaume; Coudert, François-Xavier; Kaskel, Stefan

    2016-04-21

    Adsorption-based phenomena are important in gas separations, such as the treatment of greenhouse-gas and toxic-gas pollutants, and in water-adsorption-based heat pumps for solar cooling systems. The ability to tune the pore size, shape and functionality of crystalline porous coordination polymers--or metal-organic frameworks (MOFs)--has made them attractive materials for such adsorption-based applications. The flexibility and guest-molecule-dependent response of MOFs give rise to unexpected and often desirable adsorption phenomena. Common to all isothermal gas adsorption phenomena, however, is increased gas uptake with increased pressure. Here we report adsorption transitions in the isotherms of a MOF (DUT-49) that exhibits a negative gas adsorption; that is, spontaneous desorption of gas (methane and n-butane) occurs during pressure increase in a defined temperature and pressure range. A combination of in situ powder X-ray diffraction, gas adsorption experiments and simulations shows that this adsorption behaviour is controlled by a sudden hysteretic structural deformation and pore contraction of the MOF, which releases guest molecules. These findings may enable technologies using frameworks capable of negative gas adsorption for pressure amplification in micro- and macroscopic system engineering. Negative gas adsorption extends the series of counterintuitive phenomena such as negative thermal expansion and negative refractive indices and may be interpreted as an adsorptive analogue of force-amplifying negative compressibility transitions proposed for metamaterials.

  20. Early use of negative pressure therapy in combination with silver dressings in a difficult breast abscess.

    Science.gov (United States)

    Richards, Alastair J; Hagelstein, Sue M; Patel, Girish K; Ivins, Nicola M; Sweetland, Helen M; Harding, Keith G

    2011-12-01

    Combining silver-based dressings with negative pressure therapy after radical excision of chronically infected breast disease is a novel application of two technologies. One patient with complex, chronic, infected breast disease underwent radical excision of the affected area and was treated early with a combination of silver-based dressings and topical negative pressure therapy. The wound was then assessed sequentially using clinical measurements of wound area and depth, pain severity scores and level of exudation. It is possible to combine accepted techniques with modern dressing technologies that result in a positive outcome. In this case, the combination of a silver-based dressing with negative pressure therapy following radical excision proved safe and was well tolerated by the patient. Full epithelisation of the wound was achieved and there was no recurrence of the infection for the duration of the treatment. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  1. Pressure-assisted electrokinetic injection for on-line enrichment in capillary electrophoresis-mass spectrometry: a sensitive method for measurement of ten haloacetic acids in drinking water.

    Science.gov (United States)

    Zhang, Huijuan; Zhu, Jiping; Aranda-Rodriguez, Rocio; Feng, Yong-Lai

    2011-11-07

    Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)-electrospray ionization-tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013-0.12 μg L(-1) for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  2. Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.

    Science.gov (United States)

    Bulla, Antonio; Farace, Francesco; Uzel, André-Pierre; Casoli, Vincent

    2014-07-01

    Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.

  3. Negative Pressure Pulmonary Edema Following use of Laryngeal Mask Airway (LMA

    Directory of Open Access Journals (Sweden)

    Yesim Bayraktar

    2013-06-01

    Full Text Available Negative pressure pulmonary edema (NPPE following upper airway obstruction is a non-cardiogenic pulmonary edema. The first cause in the etiology of NPPE is developed laryngospasm after intubation or extubation, while the other causes are epiglotitis, croup, hiccups, foreign body aspiration, pharyngeal hematoma and oropharyngeal tumors.The Late diagnosis and treatment causes high morbidity and mortality. The protection of the airway and maintainance of arterial oxygenation will be life saving.In this article we aimed to report  a case of negative pressure pulmonary edema, resolved succesfully after treatment, following use of laryngeal mask airway (LMA.

  4. Relaxation effects in ionic mobility and cluster formation: negative ions in SF6 at high pressures

    International Nuclear Information System (INIS)

    Juarez, A M; De Urquijo, J; Hinojosa, G; Hernandez-Avila, J L; Basurto, E

    2010-01-01

    The relaxation effects of the ionic mobility and the formation of negative-ion clusters in SF 6 are studied in this work. For this purpose, we have measured the mobility of negative ions in SF 6 over the pressure range 100-800 Torr at a fixed value of density-normalized electric field, E/N, of 20 Td (1 Townsend = 10 -17 V cm 2 ). The data obtained show a clear dependence of the negative-ion drift velocity on drift distance. It is observed that the drift velocity (mobility) reaches a steady-state value only for drift distances above 2 cm, over the studied pressure range. In addition to this, we have observed that the ionic mobility depends strongly on the gas pressure. An explanation of this dependence of the ionic mobility on gas pressure is given in terms of a negative-ion clustering formation process. It was found that the assumption of a linear dependence of the cluster ion mass on pressure provides a satisfactory explanation for the observed mobilities.

  5. Stress and Negative Relationship Quality among Older Couples: Implications for Blood Pressure.

    Science.gov (United States)

    Birditt, Kira S; Newton, Nicky J; Cranford, James A; Ryan, Lindsay H

    2016-09-01

    The cardiovascular system may represent a significant pathway by which marriage and stress influence health, but research has focused on married individuals cross-sectionally. This study examined associations among chronic stress, negative spousal relationship quality, and systolic blood pressure over time among middle-aged and older husbands and wives. Participants were from the nationally representative longitudinal Health and Retirement Study. A total of 1,356 (N = 2,712) married and cohabitating couples completed psychosocial and biomeasure assessments in waves 2006 and 2010. Analyses examined whether Wave 1 (2006) relationship quality and stress were associated with changes in blood pressure over time. The effects of stress and negative relationship quality were dyadic and varied by gender. Husbands had increased blood pressure when wives reported greater stress, and this link was exacerbated by negative spousal relationship quality. Negative relationship quality predicted increased blood pressure when both members of the couple reported negative quality relations. Findings support the dyadic biopsychosocial model of marriage and health indicating: (a) stress and relationship quality directly effect the cardiovascular system, (b) relationship quality moderates the effect of stress, and (c) the dyad rather than only the individual should be considered when examining marriage and health. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Perceiving social pressure not to feel negative predicts depressive symptoms in daily life.

    Science.gov (United States)

    Dejonckheere, Egon; Bastian, Brock; Fried, Eiko I; Murphy, Sean C; Kuppens, Peter

    2017-09-01

    Western societies often overemphasize the pursuit of happiness, and regard negative feelings such as sadness or anxiety as maladaptive and unwanted. Despite this emphasis on happiness, the amount of people suffering from depressive complaints is remarkably high. To explain this apparent paradox, we examined whether experiencing social pressure not to feel sad or anxious could in fact contribute to depressive symptoms. A sample of individuals (n = 112) with elevated depression scores (Patient Health Questionnaire [PHQ-9] ≥ 10) took part in an online daily diary study in which they rated their depressive symptoms and perceived social pressure not to feel depressed or anxious for 30 consecutive days. Using multilevel VAR models, we investigated the temporal relation between this perceived social pressure and depressive symptoms to determine directionality. Primary analyses consistently indicated that experiencing social pressure predicts increases in both overall severity scores and most individual symptoms of depression, but not vice versa. A set of secondary analyses, in which we adopted a network perspective on depression, confirmed these findings. Using this approach, centrality analysis revealed that perceived social pressure not to feel negative plays an instigating role in depression, reflected by the high out- and low instrength centrality of this pressure in the various depression networks. Together, these findings indicate how perceived societal norms may contribute to depression, hinting at a possible malignant consequence of society's denouncement of negative emotions. Clinical implications are discussed. © 2017 Wiley Periodicals, Inc.

  7. Negative magnetoresistance of pitch-based carbon fibers Temperature and pressure dependence

    Science.gov (United States)

    Hambourger, P. D.

    1986-01-01

    The negative transverse magnetoresistance of high-modulus pitch-based carbon fibers has been measured over the temperature range 1.3-4.2 K at ambient pressure and at 4.2 K under hydrostatic pressure up to 16 kbar. At low fields (less than 0.5 torr) the magnitude of the magnetoresistance increases markedly as the temperature is lowered from 4.2 K to 1.3 K, in disagreement with Bright's theoretical model, and decreases with pressure at the rate -0.6 percent/kbar.

  8. Drainage and impregnation capillary pressure curves calculated by the X-ray CT model of Berea sandstone using Lattice Boltzmann's method

    Science.gov (United States)

    Zakirov, T.; Galeev, A.; Khramchenkov, M.

    2018-05-01

    The study deals with the features of the technique for simulating the capillary pressure curves of porous media on their X-ray microtomographic images. The results of a computational experiment on the immiscible displacement of an incompressible fluid by another in the pore space represented by a digital image of the Berea sandstone are presented. For the mathematical description of two-phase fluid flow we use Lattice Boltzmann Equation (LBM), and phenomena at the fluids interface are described by the color-gradient model. Compared with laboratory studies, the evaluation of capillary pressure based on the results of a computational filtration experiment is a non-destructive method and has a number of advantages: the absence of labor for preparation of fluids and core; the possibility of modeling on the scale of very small core fragments (several mm), which is difficult to realize under experimental conditions; three-dimensional visualization of the dynamics of filling the pore space with a displacing fluid during drainage and impregnation; the possibility of carrying out multivariate calculations for specified parameters of multiphase flow (density and viscosity of fluids, surface tension, wetting contact angle). A satisfactory agreement of the capillary pressure curves during drainage with experimental results was obtained. It is revealed that with the increase in the volume of the digital image, the relative deviation of the calculated and laboratory data decreases and for cubic digital cores larger than 1 mm it does not exceed 5%. The behavior of the non-wetting fluid flow during drainage is illustrated. It is shown that flow regimes under which computational and laboratory experiments are performed the distribution of the injected phase in directions different from the gradient of the hydrodynamic drop, including the opposite ones, is characteristic. Experimentally confirmed regularities are obtained when carrying out calculations for drainage and imbibition at

  9. Using the Solving Problems Together Psychoeducational Group Counseling Model as an Intervention for Negative Peer Pressure

    Science.gov (United States)

    Hall, Kimberly R.; Rushing, Jeri Lynn; Khurshid, Ayesha

    2011-01-01

    Problem-focused interventions are considered to be one of the most effective group counseling strategies with adolescents. This article describes a problem-focused group counseling model, Solving Problems Together (SPT), that focuses on working with students who struggle with negative peer pressure. Adapted from the teaching philosophy of…

  10. Cost study of dermal substitutes and topical negative pressure in the surgical treatment of burns

    NARCIS (Netherlands)

    Hop, M.J.; Bloemen, M.C.T.; van Baar, M.E.; Nieuwenhuis, M.K.; van Zuijlen, P.P.M.; Polinder, S.; Middelkoop, E.

    2014-01-01

    AbstractBackground A recently performed randomised controlled trial investigated the clinical effectiveness of dermal substitutes (DS) and split skin grafts (SSG) in combination with topical negative pressure (TNP) in the surgical treatment of burn wounds. In the current study, medical and

  11. Pulse Waveform and Transcranial Doppler Analysis during Lower Body Negative Pressure

    Science.gov (United States)

    1993-04-01

    26, 23]. The application of negative pressure to the body for scientific or medical purposes was first used in 1841 by Junod , who used it to create a...localized hyperemia [26]. Junod also suggested that it could be used prior to invasive surgical procedures, since the syncope it was able to produce

  12. A systematic review of topical negative pressure therapy for acute and chronic wounds

    NARCIS (Netherlands)

    Ubbink, D. T.; Westerbos, S. J.; Nelson, E. A.; Vermeulen, H.

    2008-01-01

    Topical negative pressure (TNP) therapy is becoming increasingly popular for all kinds of wounds. Its clinical and cost effectiveness is unclear. A search of randomized controlled trials (RCTs) on TNP in adult patients with all kinds of wounds in all settings was undertaken in Medline, Embase,

  13. Capillary detectors

    International Nuclear Information System (INIS)

    Konijn, J.; Winter, K.; Vilain, P.; Wilquet, G.; Fabre, J.P.; Kozarenko, E.; Kreslo, I.; Goldberg, J.; Hoepfner, K.; Bay, A.; Currat, C.; Koppenburg, P.; Frekers, D.; Wolff, T.; Buontempo, S.; Ereditato, A.; Frenkel, A.; Liberti, B.; Martellotti, G.; Penso, G.; Ekimov, A.; Golovkin, S.; Govorun, V.; Medvedkov, A.; Vasil'chenko, V.

    1998-01-01

    The option for a microvertex detector using glass capillary arrays filled with liquid scintillator is presented. The status of capillary layers development and possible read-out techniques for high rate environment are reported. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  14. Improved wound management by regulated negative pressure-assisted wound therapy and regulated, oxygen- enriched negative pressure-assisted wound therapy through basic science research and clinical assessment

    Directory of Open Access Journals (Sweden)

    Moris Topaz

    2012-01-01

    Full Text Available Regulated negative pressure-assisted wound therapy (RNPT should be regarded as a state-of-the-art technology in wound treatment and the most important physical, nonpharmaceutical, platform technology developed and applied for wound healing in the last two decades. RNPT systems maintain the treated wound′s environment as a semi-closed, semi-isolated system applying external physical stimulations to the wound, leading to biological and biochemical effects, with the potential to substantially influence wound-host interactions, and when properly applied may enhance wound healing. RNPT is a simple, safe, and affordable tool that can be utilized in a wide range of acute and chronic conditions, with reduced need for complicated surgical procedures, and antibiotic treatment. This technology has been shown to be effective and safe, saving limbs and lives on a global scale. Regulated, oxygen-enriched negative pressure-assisted wound therapy (RO-NPT is an innovative technology, whereby supplemental oxygen is concurrently administered with RNPT for their synergistic effect on treatment and prophylaxis of anaerobic wound infection and promotion of wound healing. Understanding the basic science, modes of operation and the associated risks of these technologies through their fundamental clinical mechanisms is the main objective of this review.

  15. Novel cavitation fluid jet polishing process based on negative pressure effects.

    Science.gov (United States)

    Chen, Fengjun; Wang, Hui; Tang, Yu; Yin, Shaohui; Huang, Shuai; Zhang, Guanghua

    2018-04-01

    Traditional abrasive fluid jet polishing (FJP) is limited by its high-pressure equipment, unstable material removal rate, and applicability to ultra-smooth surfaces because of the evident air turbulence, fluid expansion, and a large polishing spot in high-pressure FJP. This paper presents a novel cavitation fluid jet polishing (CFJP) method and process based on FJP technology. It can implement high-efficiency polishing on small-scale surfaces in a low-pressure environment. CFJP uses the purposely designed polishing equipment with a sealed chamber, which can generate a cavitation effect in negative pressure environment. Moreover, the collapse of cavitation bubbles can spray out a high-energy microjet and shock wave to enhance the material removal. Its feasibility is verified through researching the flow behavior and the cavitation results of the negative pressure cavitation machining of pure water in reversing suction flow. The mechanism is analyzed through a computational fluid dynamics simulation. Thus, its cavitation and surface removal mechanisms in the vertical CFJP and inclined CFJP are studied. A series of polishing experiments on different materials and polishing parameters are conducted to validate its polishing performance compared with FJP. The maximum removal depth increases, and surface roughness gradually decreases with increasing negative outlet pressures. The surface becomes smooth with the increase of polishing time. The experimental results confirm that the CFJP process can realize a high material removal rate and smooth surface with low energy consumption in the low-pressure environment, together with compatible surface roughness to FJP. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Automated Parallel Capillary Electrophoretic System

    Science.gov (United States)

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2000-02-22

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  17. Using portable negative pressure wound therapy devices in the home care setting

    Directory of Open Access Journals (Sweden)

    Burke JR

    2014-12-01

    Full Text Available Joshua R Burke, Rachael Morley, Mustafa Khanbhai Academic Surgery Unit, Education and Research Centre, University Hospital of South Manchester, Manchester, UK Abstract: Negative pressure wound therapy (NPWT is the continuous or intermittent application of subatmospheric pressure to the surface of a wound that improves the wound environment, accelerates healing, and reduces wound closure time. Since its first documented use, this technology has lent itself to a number of adaptations, most notably, the development of portable devices facilitating treatment in the home care setting. With advancing surgical standards, wound healing is an important rate-limiting factor in early patient discharge and often a major cost of inpatient treatment. The efficacy of NPWT in the home care setting has been investigated through rate of wound closure, time in care, and patient experience. Rate of wound closure is the most appropriate primary end point. Much can be gleaned from patient experience, but the future success of portable NPWT will be measured on time in care and therefore cost effectiveness. However, there is a lack of level 1a evidence demonstrating increased efficacy of portable over inpatient NPWT. The development of portable NPWT is an encouraging innovation in wound care technology, and extending the benefits to the home care setting is both possible and potentially more beneficial. Keywords: portable, negative pressure wound therapy, vacuum-assisted closure, topical negative pressure therapy

  18. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473 K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements

    Science.gov (United States)

    Lu, Wanjun; Guo, Huirong; Chou, I.-Ming; Burruss, R.C.; Li, Lanlan

    2013-01-01

    Accurate values of diffusion coefficients for carbon dioxide in water and brine at reservoir conditions are essential to our understanding of transport behavior of carbon dioxide in subsurface pore space. However, the experimental data are limited to conditions at low temperatures and pressures. In this study, diffusive transfer of carbon dioxide in water at pressures up to 45 MPa and temperatures from 268 to 473 K was observed within an optical capillary cell via time-dependent Raman spectroscopy. Diffusion coefficients were estimated by the least-squares method for the measured variations in carbon dioxide concentration in the cell at various sample positions and time. At the constant pressure of 20 MPa, the measured diffusion coefficients of carbon dioxide in water increase with increasing temperature from 268 to 473 K. The relationship between diffusion coefficient of carbon dioxide in water [D(CO2) in m2/s] and temperature (T in K) was derived with Speedy–Angell power-law approach as: D(CO2)=D0[T/Ts-1]m where D0 = 13.942 × 10−9 m2/s, Ts = 227.0 K, and m = 1.7094. At constant temperature, diffusion coefficients of carbon dioxide in water decrease with pressure increase. However, this pressure effect is rather small (within a few percent).

  19. [The influence of oxygen partial pressure change and vascularization of rabbit wound through negative pressure wound therapy].

    Science.gov (United States)

    Yang, Fan; Hu, Duan; Bai, Xiang-jun; Zhang, Kun; Li, Ren-jie; Xue, Chen-chen

    2012-07-01

    To investigate the effect of vacuum sealing drainage (VSD) on variation of oxygen partial pressure (PtO2) and vascularization. The 12 cases of rabbit's wound models were undergoing the VSD (vacuum group, n = 6) or conventional therapy (conventional group, n = 6). Variation of PtO2 was measured by oxygen partial pressure admeasuring apparatus, expression of hypoxia inducible factor 1α (HIF-1α) mRNA was measured by real-time fluorescent quantitative PCR, content of vascular endothelial growth factor (VEGF) was measured by ELISA after tissue homogenate in 7 days. Vascular endothelial cell (VEC) and new blood capillary (NBC) of hematoxylin-eosin slice of tissue were counted by using light microscope. Average value of PtO2 of vacuum group was significant lower than conventional group (t = -99.780 to -5.305, P < 0.01). Expression of HIF-1α (30 minutes, 1, 6, 12 hours were 3.11 ± 0.07, 3.68 ± 0.26, 4.16 ± 0.13 and 3.91 ± 0.26 respectively) and content of VEGF (30 minutes, 1, 6, 12 hours were 103.3 ± 2.4, 134.2 ± 9.0, 167.8 ± 3.8 and 232.1 ± 9.5 respectively) of vacuum group were increased after 30 minutes and significant lower than conventional group (t = 13.038 - 80.208, P < 0.01), and both of them were reduced after 24 hours (P < 0.05). Counting numbers of VEC (2.47 ± 0.45 to 4.70 ± 0.38) and NBC (1.33 ± 0.49 to 4.33 ± 0.68) of vacuum group were increased at the same time-point and significant higher than conventional group (t = -0.670 to 16.500, P < 0.05). PtO2 of wound surface could be reduced significantly by VSD. Expression of HIF-1α and content of VEGF were increased by VSD for enhancing differentiated state of VEC and construction of NBC, which were better for vascularization and wound healing.

  20. The evidence-based principles of negative pressure wound therapy in trauma & orthopedics.

    Science.gov (United States)

    A, Novak; Khan, Wasim S; J, Palmer

    2014-01-01

    Negative pressure wound therapy is a popular treatment for the management of both acute and chronic wounds. Its use in trauma and orthopedics is diverse and includes the acute traumatic setting as well as chronic troublesome wounds associated with pressure sores and diabetic foot surgery. Efforts have been made to provide an evidence base to guide its use however this has been limited by a lack of good quality evidence. The following review article explores the available evidence and describes future developments for its use in trauma and orthopaedic practice.

  1. Early activation of the coagulation system during lower body negative pressure

    DEFF Research Database (Denmark)

    Zaar, M; Johansson, P I; Nielsen, L B

    2009-01-01

    We considered that a moderate reduction of the central blood volume (CBV) may activate the coagulation system. Lower body negative pressure (LBNP) is a non-invasive means of reducing CBV and, thereby, simulates haemorrhage. We tested the hypothesis that coagulation markers would increase following...... moderate hypovolemia by exposing 10 healthy male volunteers to 10 min of 30 mmHg LBNP. Thoracic electrical impedance increased during LBNP (by 2.6 +/- 0.7 Omega, mean +/- SD; P pressure decreased (84 +/- 5 to 80...

  2. Effect of venous and lymphatic congestion on lymph capillary pressure of the skin in healthy volunteers and patients with lymph edema.

    Science.gov (United States)

    Gretener, S B; Läuchli, S; Leu, A J; Koppensteiner, R; Franzeck, U K

    2000-01-01

    The aim of the present study was to assess the influence of venous and lymphatic congestion on lymph capillary pressure (LCP) in the skin of the foot dorsum of healthy volunteers and of patients with lymph edema. LCP was measured at the foot dorsum of 12 patients with lymph edema and 18 healthy volunteers using the servo-nulling technique. Glass micropipettes (7-9 microm) were inserted under microscopic control into lymphatic microvessels visualized by fluorescence microlymphography before and during venous congestion. Venous and lymphatic congestion was attained by cuff compression (50 mm Hg) at the thigh level. Simultaneously, the capillary filtration rate was measured using strain gauge plethysmography. The mean LCP in patients with lymph edema increased significantly (p < 0.05) during congestion (15.7 +/- 8.8 mm Hg) compared to the control value (12.2 +/- 8.9 mm Hg). The corresponding values of LCP in healthy volunteers were 4.3 +/- 2.6 mm Hg during congestion and 2.6 +/- 2.8 mm Hg during control conditions (p < 0.01). The mean increase in LCP in patients with lymph edema was 3.4 +/- 4.1 mm Hg, and 1.7 +/- 2.0 mm Hg in healthy volunteers (NS). The maximum spread of the lymph capillary network in patients increased from 13.9 +/- 6.8 mm before congestion to 18.8 +/- 8.2 mm during thigh compression (p < 0.05). No increase could be observed in healthy subjects. In summary, venous and lymphatic congestion by cuff compression at the thigh level results in a significant increase in LCP in healthy volunteers as well as in patients with lymph edema. The increased spread of the contrast medium in the superficial microlymphatics in lymph edema patients indicates a compensatory mechanism for lymphatic drainage during congestion of the veins and lymph collectors of the leg. Copyright 2000 S. Karger AG, Basel

  3. Head holder using negative pressure bag packed with plastic beads in xenon CT CBF study

    International Nuclear Information System (INIS)

    Araki, Yuzo; Sakai, Noboru

    2003-01-01

    Employing analysis of cerebral blood flow (CBF) confidence maps, we investigated the usefulness of a head holder using a negative pressure bag packed with plastic beads in a xenon CT CBF study. A total of 272 consecutive patients for the CBF study were enrolled and classified into 3 groups: 88 patients with a negative pressure bag (M group), 87 patients with an air pillow (A group), and 97 patients with a sponge pillow (S group). The degree of effect of head movements on the CBF measurement in each patient was expressed as a confidence value (mean of the confidence values at one CT slice). The mean of confidence value in the M group (0.461) was statistically lower than that in the A group (0.866) and that in the S group (1.043). These findings showed that the head holder described here was useful for obtaining CBF maps of high quality in a xenon CT CBF study. (author)

  4. Negative pressure darwinism: survival of the fittest paradigm.

    Science.gov (United States)

    Miller, Michael; Bybordi, Farhad

    2009-07-01

    The use of negative pressure for wound healing has been based on a set of parameters and devices that until recently were combined into a single paradigm. Despite historical and more recent evidence providing viable alternative considerations, it is only recently that this paradigm and its tenets have come into question. As the understanding of the limits of the current paradigm and specific instances of its benefits and drawbacks are identified, shifts in the paradigm must take place if the therapy is to evolve, develop, and continue to be efficacious. The pertinence of the concept of survival of the fittest is used to explore the need for a paradigm shift in negative pressure wound therapy.

  5. Negative Gauge Pressure Moisture Management and Secure Adherence Device for Prosthetic Limbs

    Science.gov (United States)

    2013-03-01

    prosthesis feels like it is sliding up and down or falling off when I am active. D. I have been more active than normal as a result of this prosthesis ...temperature. 3. My prosthesis feels like it is sliding up and down or falling off when I am active. 4. I have been more active than normal as a result of...objective of this research was to develop and test a novel prosthesis incorporating a negative gauge pressure moisture management and secure

  6. Histomorphological observation of surgical debridement combined with negative pressure therapy in treatment of diabetic foot

    Directory of Open Access Journals (Sweden)

    Jiao-Yun Dong

    2017-08-01

    Conclusion: Epidermal cells on the fascia side of the flap could be derived from the stem cells. Negative pressure wound therapy would attract not only cells but also other elements such as growth factors, cytokines, some nutrients and extracellular matrix. With the formation of the appropriate microenvironment after debridement, the migrated cells can grow, differentiate and spread, eventually leading to the epithelization on the fascia side of the flap in diabetic foot.

  7. Facets of negative affectivity and blood pressure in middle-aged men

    Directory of Open Access Journals (Sweden)

    Cornel V. Igna

    2013-04-01

    Full Text Available Research results suggesting that facets of negative affectivity, i.e. anxiety, anger-hostility, and depression, relate to incident cardiovascular diseases have been steadily increasing. Evidence for depression has been especially extensive. Elevated blood pressure, a major risk factor of cardiovascular diseases, is one probable mediator in this context. The purpose of this study was to clarify the relationship of specific key elements of depressive disposition, i.e. depressive symptoms, hopelessness and vital exhaustion, with health behavior and blood pressure. Study sample was comprised of 710 middle-aged men. Participants completed self-report questionnaires assessing health behavior, depressive symptoms, vital exhaustion and hopelessness. Statistical analyses involved descriptive analyses, correlations and path analysis. Depressive symptoms and vital exhaustion associated with several unfavorable lifestyles such as smoking, alcohol consumption, and inactivity (standardized solution coefficients: 0.10, 0.14, 0.17, accordingly. However, no significant direct associations with blood pressure could be found for depressive symptoms or vital exhaustion. Hopelessness associated only with unhealthy diet (standardized solution coefficient -0.10 Moreover, for hopelessness, results showed a direct but inverse association with systolic blood pressure (standardized solution coefficient -0.08. Results suggest that the previously reported relations of depression and vital exhaustion with blood pressure could be mediated by unfavorable lifestyles. The relation of hopelessness with adverse health behaviors seems to be less significant. Also, the role of hopelessness as a risk factor of elevated blood pressure is not supported by the results of this study.

  8. Using negative pressure therapy for improving skin graft taking on genital area defects following Fournier gangrene.

    Science.gov (United States)

    Orhan, Erkan; Şenen, Dilek

    2017-09-01

    Fournier's gangrene is an infective necrotizing fasciitis of the perineal, genital and perianal regions. Treatment includes aggressive surgical debridement that often results in extensive loss of genital skin. Skin grafts may be used for reconstruction but skin grafting of the male genitalia is diffucult because the penis and scrotum are mobile and deformable. A variety of methods are used to secure skin graft to recipient beds. We used negative pressure therapy (NPT) to secure skin grafts and improve skin graft taking. We used negative pressure therapy for graft fixation in 13 male patients who underwent debridements with the indication of Fournier gangrene, and whose defects formed were reconstructed with grafts between January 2009, and January 2014. Information about age of the patients, sessions of negative pressure therapy applied before, and after reconstruction, duration of hospital stay, and graft losses during postoperative period were recorded. Median age of the patients was 56.15 (46-72) years. NPT was applied to patients for an average of 6.64 sessions (4-12) before and 1 sessions after graft reconstruction. Patients were hospitalized for an average of 26.7 (20-39) days. Any graft loss was not seen after NPT. Because of the peculiar anatomy of the genital region, anchoring of grafts is difficult so graft losses are often encountered. Use of NPT for ensuring graft fixation on the genital region prevents skin graft shearing.

  9. Negative pressure pulmonary edema after nasal fracture reduction in an obese female patient: a case report

    Directory of Open Access Journals (Sweden)

    Choi EK

    2015-08-01

    Full Text Available Eunkyung Choi,1 Junggu Yi,1 Younghoon Jeon,2 1Department of Anesthesiology and Pain Medicine, School of Medicine, Kyungpook National University, Daegu, Republic of Korea; 2Department of Anesthesiology and Pain Medicine, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea Abstract: Postoperative negative pressure pulmonary edema (NPPE is a rare, but well-known life-threatening complication of acute upper airway obstruction (UAO which develops after general anesthesia. The pronounced inspiratory efforts following UAO lead to excessive negative inspiratory pressure, which may cause acute pulmonary edema. Early recognition and prompt treatment of NPPE is necessary to prevent patient morbidity and mortality. In addition, the physician should carefully manage the patient who has risk factors of UAO to prevent this situation. We experienced a case of NPPE following laryngospasm after tracheal extubation in an obese patient who underwent open reduction of orbital wall and nasal bone surgery. Keywords: airway obstruction, negative pressure pulmonary edema, laryngospasm, nasal surgery, obese

  10. Negative Pressures and the First Water Siphon Taller than 10.33 Meters.

    Directory of Open Access Journals (Sweden)

    Francisco Vera

    Full Text Available A siphon is a device that is used to drain a container, with water rising inside a hose in the form of an inverted U and then going down towards a discharge point placed below the initial water level. The siphon is the first of a number of inventions of the ancients documented about 2.000 years ago by Hero of Alexandria in his treatise Pneumatics, and although the explanation given by Hero was essentially correct, there is nowadays a controversy about the underlying mechanism that explains the working of this device. Discussions concerning the physics of a siphon usually refer to concepts like absolute negative pressures, the strength of liquid's cohesion and the possibility of a siphon working in vacuum or in the presence of bubbles. Torricelli understood the working principle of the barometer and the impossibility of pumping water out of wells deeper than 10.33 m. Following Torricelli's ideas it would also not be possible to build a siphon that drives pure water to ascend higher than 10.33 m. In this work, we report the first siphon that drives water (with surfactant to ascend higher than the Torricellian limit. Motivated by the rising of sap in trees, we built a 15.4 m siphon that shows that absolute negative pressures are not prohibited, that cohesion plays an important role in transmitting forces through a fluid, and that surfactants can help to the transport of water in a metastable regime of negative pressures.

  11. A pilot randomised controlled trial of negative pressure wound therapy to treat grade III/IV pressure ulcers [ISRCTN69032034

    Science.gov (United States)

    2012-01-01

    Background Negative pressure wound therapy (NPWT) is widely promoted as a treatment for full thickness wounds; however, there is a lack of high-quality research evidence regarding its clinical and cost effectiveness. A trial of NPWT for the treatment of grade III/IV pressure ulcers would be worthwhile but premature without assessing whether such a trial is feasible. The aim of this pilot randomised controlled trial was to assess the feasibility of conducting a future full trial of NPWT for the treatment of grade III and IV pressure ulcers and to pilot all aspects of the trial. Methods This was a two-centre (acute and community), pilot randomised controlled trial. Eligible participants were randomised to receive either NPWT or standard care (SC) (spun hydrocolloid, alginate or foam dressings). Outcome measures were time to healing of the reference pressure ulcer, recruitment rates, frequency of treatment visits, resources used and duration of follow-up. Results Three hundred and twelve patients were screened for eligibility into this trial over a 12-month recruitment period and 12/312 participants (3.8%) were randomised: 6 to NPWT and 6 to SC. Only one reference pressure ulcer healed (NPWT group) during follow-up (time to healing 79 days). The mean number of treatment visits per week was 3.1 (NPWT) and 5.7 (SC); 6/6 NPWT and 1/6 SC participants withdrew from their allocated trial treatment. The mean duration of follow-up was 3.8 (NPWT) and 5.0 (SC) months. Conclusions This pilot trial yielded vital information for the planning of a future full study including projected recruitment rate, required duration of follow-up and extent of research nurse support required. Data were also used to inform the cost-effectiveness and value of information analyses, which were conducted alongside the pilot trial. Trial registration Current Controlled Trials ISRCTN69032034. PMID:22839453

  12. A pilot randomised controlled trial of negative pressure wound therapy to treat grade III/IV pressure ulcers [ISRCTN69032034

    Directory of Open Access Journals (Sweden)

    Ashby Rebecca L

    2012-07-01

    Full Text Available Abstract Background Negative pressure wound therapy (NPWT is widely promoted as a treatment for full thickness wounds; however, there is a lack of high-quality research evidence regarding its clinical and cost effectiveness. A trial of NPWT for the treatment of grade III/IV pressure ulcers would be worthwhile but premature without assessing whether such a trial is feasible. The aim of this pilot randomised controlled trial was to assess the feasibility of conducting a future full trial of NPWT for the treatment of grade III and IV pressure ulcers and to pilot all aspects of the trial. Methods This was a two-centre (acute and community, pilot randomised controlled trial. Eligible participants were randomised to receive either NPWT or standard care (SC (spun hydrocolloid, alginate or foam dressings. Outcome measures were time to healing of the reference pressure ulcer, recruitment rates, frequency of treatment visits, resources used and duration of follow-up. Results Three hundred and twelve patients were screened for eligibility into this trial over a 12-month recruitment period and 12/312 participants (3.8% were randomised: 6 to NPWT and 6 to SC. Only one reference pressure ulcer healed (NPWT group during follow-up (time to healing 79 days. The mean number of treatment visits per week was 3.1 (NPWT and 5.7 (SC; 6/6 NPWT and 1/6 SC participants withdrew from their allocated trial treatment. The mean duration of follow-up was 3.8 (NPWT and 5.0 (SC months. Conclusions This pilot trial yielded vital information for the planning of a future full study including projected recruitment rate, required duration of follow-up and extent of research nurse support required. Data were also used to inform the cost-effectiveness and value of information analyses, which were conducted alongside the pilot trial. Trial registration Current Controlled Trials ISRCTN69032034.

  13. Lower body negative pressure as a tool for research in aerospace physiology and military medicine

    Science.gov (United States)

    Convertino, V. A.

    2001-01-01

    Lower body negative pressure (LBNP) has been extensively used for decades in aerospace physiological research as a tool to investigate cardiovascular mechanisms that are associated with or underlie performance in aerospace and military environments. In comparison with clinical stand and tilt tests, LBNP represents a relatively safe methodology for inducing highly reproducible hemodynamic responses during exposure to footward fluid shifts similar to those experienced under orthostatic challenge. By maintaining an orthostatic challenge in a supine posture, removal of leg support (muscle pump) and head motion (vestibular stimuli) during LBNP provides the capability to isolate cardiovascular mechanisms that regulate blood pressure. LBNP can be used for physiological measurements, clinical diagnoses and investigational research comparisons of subject populations and alterations in physiological status. The applications of LBNP to the study of blood pressure regulation in spaceflight, groundbased simulations of low gravity, and hemorrhage have provided unique insights and understanding for development of countermeasures based on physiological mechanisms underlying the operational problems.

  14. Negative-pressure and low-pressure hydrocephalus: the role of cerebrospinal fluid leaks resulting from surgical approaches to the cranial base.

    Science.gov (United States)

    Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L

    2011-11-01

    Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.

  15. Evaluation of negative pressure vacuum-assisted system in acute and chronic wounds closure: our experience.

    Science.gov (United States)

    Chiummariello, S; Guarro, G; Pica, A; Alfano, C

    2012-10-01

    Negative-pressure therapy or vacuum-assisted closure (VAC) has been used in clinical applications since the 1940's and has increased in popularity over the past decade. This dressing technique consists of an open cell foam dressing put into the wound cavity, a vacuum pump produces a negative pressure and an adhesive drape. A controlled sub atmospheric pressure from 75 to 150 mmHg is applied. The vacuum-assisted closure has been applied by many clinicians to chronic wounds in humans; however it cannot be used as a replacement for surgical debridement. The initial treatment for every contaminated wound should be the necrosectomy. The VAC therapy has a complementary function and the range of its indications includes pressure sores, stasis ulcers, chronic wounds such as diabetic foot ulcers, post traumatic and post operative wounds, infected wounds such as necrotizing fasciitis or sternal wounds, soft-tissue injuries, bone exposed injuries, abdominal open wounds and for securing a skin graft. We describe our experience with the VAC dressing used to manage acute and chronic wounds in a series of 135 patients, with excellent results together with satisfaction of the patients.

  16. Differential effects of lower body negative pressure and upright tilt on splanchnic blood volume

    Science.gov (United States)

    Taneja, Indu; Moran, Christopher; Medow, Marvin S.; Glover, June L.; Montgomery, Leslie D.; Stewart, Julian M.

    2015-01-01

    Upright posture and lower body negative pressure (LBNP) both induce reductions in central blood volume. However, regional circulatory responses to postural changes and LBNP may differ. Therefore, we studied regional blood flow and blood volume changes in 10 healthy subjects undergoing graded lower-body negative pressure (−10 to −50 mmHg) and 8 subjects undergoing incremental head-up tilt (HUT; 20°, 40°, and 70°) on separate days. We continuously measured blood pressure (BP), heart rate, and regional blood volumes and blood flows in the thoracic, splanchnic, pelvic, and leg segments by impedance plethysmography and calculated regional arterial resistances. Neither LBNP nor HUT altered systolic BP, whereas pulse pressure decreased significantly. Blood flow decreased in all segments, whereas peripheral resistances uniformly and significantly increased with both HUT and LBNP. Thoracic volume decreased while pelvic and leg volumes increased with HUT and LBNP. However, splanchnic volume changes were directionally opposite with stepwise decreases in splanchnic volume with LBNP and stepwise increases in splanchnic volume during HUT. Splanchnic emptying in LBNP models regional vascular changes during hemorrhage. Splanchnic filling may limit the ability of the splanchnic bed to respond to thoracic hypovolemia during upright posture. PMID:17085534

  17. Timer switch to convert suction apparatus for negative pressure wound therapy application

    Directory of Open Access Journals (Sweden)

    Surath Amarnath

    2014-01-01

    Full Text Available Background: Negative pressure wound therapy (NPWT is an established modality in the treatment of chronic wounds, open fractures, and post-operative wound problems. This method has not been widely used due to the high cost of equipment and consumables. This study demonstrates an indigenously developed apparatus which gives comparable results at a fraction of the cost. Readily available materials are used for the air-tight dressing. Materials and Methods: Equipment consists of suction apparatus with adjustable pressure valve set to a pressure 125-150 mmHg. An electronic timer switch with a sequential working time of 5 min and a standby time of 3 min provides the required intermittent negative pressure. Readily available materials such as polyvinyl alcohol sponge, suction drains and steridrapes were used to provide an air tight wound cover. Results: A total of 90 cases underwent 262 NPWT applications from 2009 to 2014. This series, comprised of 30 open fractures, 21 post-operative and 39 chronic wounds. The wound healing rate in our study was comparable to other published studies using NPWT. Conclusion: The addition of electronic timer switch will convert a suction apparatus into NPWT machine, and the results are equally effective compared to more expensive counter parts. The use of indigenous dressing materials reduces the cost significantly.

  18. Patients' experiences of negative pressure wound therapy for the treatment of wounds: a review.

    Science.gov (United States)

    Upton, D; Stephens, D; Andrews, A

    2013-01-01

    To review the research on patients' experiences of undergoing negative pressure wound therapy (NPWT). A literature search was carried out using the following databases: Academic Search Complete, CINAHL, PsychINFO, MEDLINE, PubMed and PsyARTICLES. The search covered the period from 2001 to 2012, using the key words: ['negative pressure wound therapy' OR 'vacuum-assisted closure' OR 'topical negative therapy'] AND ['patients' experiences' OR 'psychological' OR 'stress' OR 'anxiety' OR 'wellbeing' OR 'pain' OR 'quality of life' OR 'physical']. Twenty-five relevant articles were included. NPWT is generally considered to be successful in reducing wound depth and facilitating healing. However, studies have highlighted a number of issues that need to be considered. For example, the type of dressing used during treatment can have a significant effect on patients' experience of pain. Furthermore, the NPWT system can cause patients to feel anxious due to both the patient and the health professional being unfamiliar with this form of treatment. It can also restrict patients' daily care and wider social life, which may result in a negative self-image and low self-esteem. Despite this, some studies have reported positive improvements to patients' quality of life. Additionally, since NPWT can lead to faster healing, any detrimental impact upon patients' wellbeing may be short-term and less prolonged than that of other treatments. Compared with other treatments, there is evidence to show that NPWT can lead to faster wound healing, and a reduced frequency of dressing changes and other treatments. However, there are a number of challenges with the use of NPWT, which need to be explored further so that improvements can be made. Specifically, certain aspects of NPWT may impact negatively on patients' wellbeing, albeit short-term. Therefore, research needs to explore patients' experience of NPWT throughout the treatment process and to consider how this can be improved to minimise any

  19. Capillary pressure controlled methane hydrate and ice growth-melting patterns in porous media : synthetic silica versus natural sandstone

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.; Tohidi, B.; Webber, B. [Heriot-Watt Univ., Centre for Gas Research, Edinburgh (United Kingdom). Inst. of Petroleum Engineering

    2008-07-01

    Although naturally-occurring gas hydrates (or clathrate hydrates) in marine sediments can pose a hazard to deepwater hydrocarbon production operations, they represent a potential strategic energy reserve. Gas hydrates can also provide a means for deep ocean carbon dioxide disposal through sequestration/storage. They have long-term importance with respect to ocean margin stability, methane release, and global climate change. However, fundamental knowledge is still lacking regarding the mechanisms of hydrate growth, accumulation and distribution within the subsurface. Marine sediments which host gas hydrates are commonly fine-grained silts, muds, and clays with narrow mean pore diameters, leading to speculation that capillary phenomena could play a significant role in controlling hydrate distribution in the seafloor, and may be partly responsible for discrepancies between observed and predicted hydrate stability zone thicknesses. A close relationship between hydrate inhibition and pore size has been confirmed through previous laboratory studies. Clathrate stability has been significantly reduced in narrow pores. However, the focus of investigations has generally been hydrate dissociation conditions in porous media, with capillary controls on the equally important process of hydrate growth being largely overlooked. This paper presented the results of an experimental investigation into methane hydrate growth and dissociation equilibria in natural medium grained sandstone. The study also compared data with that previously measured for mesoporous silica glasses. The paper discussed solid-liquid phase behaviour in confined geometries including hysteresis in porous media. It also discussed the experimental equipment and method. It was concluded that, as for synthetic silicas, hydrate growth and dissociation in the sandstone were characterised by a measurable hysteresis between opposing transitions, notably hydrate (or ice) formation occurring at temperatures lower than

  20. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    Science.gov (United States)

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  1. Solid-Phase Microextraction Coupled to Capillary Atmospheric Pressure Photoionization-Mass Spectrometry for Direct Analysis of Polar and Nonpolar Compounds.

    Science.gov (United States)

    Mirabelli, Mario F; Zenobi, Renato

    2018-04-17

    A novel capillary ionization source based on atmospheric pressure photoionization (cAPPI) was developed and used for the direct interfacing between solid-phase microextraction (SPME) and mass spectrometry (MS). The efficiency of the source was evaluated for direct and dopant-assisted photoionization, analyzing both polar (e.g., triazines and organophosphorus pesticides) and nonpolar (polycyclic aromatic hydrocarbons, PAHs) compounds. The results show that the range of compound polarity, which can be addressed by direct SPME-MS can be substantially extended by using cAPPI, compared to other sensitive techniques like direct analysis in real time (DART) and dielectric barrier discharge ionization (DBDI). The new source delivers a very high sensitivity, down to sub parts-per-trillion (ppt), making it a viable alternative when compared to previously reported and less comprehensive direct approaches.

  2. Extraction of water labeled with oxygen 15 during single-capillary transit. Influence of blood pressure, osmolarity, and blood-brain barrier damage

    International Nuclear Information System (INIS)

    Go, K.G.; Lammertsma, A.A.; Paans, A.M.; Vaalburg, W.; Woldring, M.G.

    1981-01-01

    By external detection, the influence of arterial blood pressure (BP), osmolarity, and cold-induced blood-brain barrier damage was assessed on the extraction of water labeled with oxygen 15 during single-capillary transit in the rat. There was an inverse relation between arterial BP and extraction that was attributable to the influence of arterial BP on cerebral blood flow (CBF) and the relation between CBF and extraction. Neither arterial BP nor osmolarity of the injected bolus had any direct effect on extraction of water 15O, signifying that the diffusional exchange component (determined by blood flow) of extraction greatly surpasses the convection flow contribution by hydrostatic or osmotic forces. Damage to the blood-brain barrier did not change its permeability to water

  3. Simultaneous separation of water- and fat-soluble vitamins in isocratic pressure-assisted capillary electrochromatography using a methacrylate-based monolithic column.

    Science.gov (United States)

    Yamada, Hiroki; Kitagawa, Shinya; Ohtani, Hajime

    2013-06-01

    A method of simultaneous separation of water- and fat-soluble vitamins using pressure-assisted CEC with a methacrylate-based capillary monolithic column was developed. In the proposed method, water-soluble vitamins were mainly separated electrophoretically, while fat soluble-ones were separated chromatographically by the interaction with a methacrylate-based monolith. A mixture of six water-soluble and four fat-soluble vitamins was separated simultaneously within 20 min with an isocratic elution using 1 M formic acid (pH 1.9)/acetonitrile (30:70, v/v) containing 10 mM ammonium formate as a mobile phase. When the method was applied to a commercial multivitamin tablet and a spiked one, the vitamins were successfully analyzed, and no influence of the matrix contained in the tablet was observed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Abdominal compartment syndrome and open abdomen management with negative pressure devices.

    Science.gov (United States)

    Surace, Alessandra; Ferrarese, Alessia; Marola, Silvia; Cumbo, Jacopo; Valentina, Gentile; Borello, Alessandro; Solej, Mario; Martino, Valter; Nano, Mario

    2015-01-01

    Abdominal compartment syndrome (ACS) is defined as an increase of intra-abdominal pressure (IAH) to values higher than 20 mmHg, associated with reduced perfusion and organ dysfunction. There is a classification of open abdomen which stratifies patients according to the natural history of improvement or clinical deterioration. The aim of treatment is to maintain the open abdomen at the lowest level and to prevent progression to a more complex level. Surgical treatment essentially consists in abdominal decompression by leaving the abdomen open. Analysis of the literature shows that negative pressure increases the rate of primary fascial closure; entero-cutaneous fistulas are seen in a minority of cases, without seeming consequence of the application of the dressing. Open abdomen management consists of three treatment stages: acute (24-48 hours), intermediate (from 48 hours to 10 days) and late or reconstruction (from 10 days to the final closure). It's important to recognize patients at risk of IAH and the first signs of ACS and intervene early with abdominal decompression if this will establish itself. Management of the open abdomen is now facilitated by negative pressure devices, which positively affect the morbidity and mortality of patients with ACS.

  5. An improved method for estimating capillary pressure from 3D microtomography images and its application to the study of disconnected nonwetting phase

    Science.gov (United States)

    Li, Tianyi; Schlüter, Steffen; Dragila, Maria Ines; Wildenschild, Dorthe

    2018-04-01

    We present an improved method for estimating interfacial curvatures from x-ray computed microtomography (CMT) data that significantly advances the potential for this tool to unravel the mechanisms and phenomena associated with multi-phase fluid motion in porous media. CMT data, used to analyze the spatial distribution and capillary pressure-saturation (Pc-S) relationships of liquid phases, requires accurate estimates of interfacial curvature. Our improved method for curvature estimation combines selective interface modification and distance weighting approaches. It was verified against synthetic (analytical computer-generated) and real image data sets, demonstrating a vast improvement over previous methods. Using this new tool on a previously published data set (multiphase flow) yielded important new insights regarding the pressure state of the disconnected nonwetting phase during drainage and imbibition. The trapped and disconnected non-wetting phase delimits its own hysteretic Pc-S curve that inhabits the space within the main hysteretic Pc-S loop of the connected wetting phase. Data suggests that the pressure of the disconnected, non-wetting phase is strongly modified by the pore geometry rather than solely by the bulk liquid phase that surrounds it.

  6. Synthesis of capillary pressure curves from post-stack seismic data with the use of intelligent estimators: A case study from the Iranian part of the South Pars gas field, Persian Gulf Basin

    Science.gov (United States)

    Golsanami, Naser; Kadkhodaie-Ilkhchi, Ali; Erfani, Amir

    2015-01-01

    Capillary pressure curves are important data for reservoir rock typing, analyzing pore throat distribution, determining height above free water level, and reservoir simulation. Laboratory experiments provide accurate data, however they are expensive, time-consuming and discontinuous through the reservoir intervals. The current study focuses on synthesizing artificial capillary pressure (Pc) curves from seismic attributes with the use of artificial intelligent systems including Artificial Neural Networks (ANNs), Fuzzy logic (FL) and Adaptive Neuro-Fuzzy Inference Systems (ANFISs). The synthetic capillary pressure curves were achieved by estimating pressure values at six mercury saturation points. These points correspond to mercury filled pore volumes of core samples (Hg-saturation) at 5%, 20%, 35%, 65%, 80%, and 90% saturations. To predict the synthetic Pc curve at each saturation point, various FL, ANFIS and ANN models were constructed. The varying neural network models differ in their training algorithm. Based on the performance function, the most accurately functioning models were selected as the final solvers to do the prediction process at each of the above-mentioned mercury saturation points. The constructed models were then tested at six depth points of the studied well which were already unforeseen by the models. The results show that the Fuzzy logic and neuro-fuzzy models were not capable of making reliable estimations, while the predictions from the ANN models were satisfyingly trustworthy. The obtained results showed a good agreement between the laboratory derived and synthetic capillary pressure curves. Finally, a 3D seismic cube was captured for which the required attributes were extracted and the capillary pressure cube was estimated by using the developed models. In the next step, the synthesized Pc cube was compared with the seismic cube and an acceptable correspondence was observed.

  7. Increased serum urea to creatinine ratio and its negative correlation with arterial pressure in canine babesiosis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga

    2014-09-01

    The increase of the serum urea to creatinine ratio (UCR) was observed in dogs infected with Babesia canis. Previous studies have suggested that decrease of blood pressure can be one of the reasons for this phenomenon. In this work statistically significant increase of the UCR was observed in dogs with babesiosis. Comparison of the UCR between 23 azotaemic dogs and 25 non-azotaemic dogs infected with Babesia canis showed statistically significantly higher mean of the UCR in azotaemic dogs. Correlations between UCR and systolic, diastolic and mean arterial pressure (SAP, DAP and MAP) in 48 dogs infected with B. canis were negative (UCR and SAP: r = -0.3909; UCR and DAP: r = -0.3182; UCR and MAP: r = -0.3682) and statistically significant (p high, and there was no statistically significant correlation between UCR and arterial pressures in azotaemic dogs. Thus, it seems that decrease of blood pressure in dogs with babesiosis explains only partially the cause of increased UCR in infected dogs. The other authors suggested hyperureagenesis and myocardial injury as a potential reason for the increased UCR in canine babesiosis. Thus, further studies are needed to determine causes of increased UCR in dogs with babesiosis, especially on the connection between UCR changes and the concentrations of plasma cardiac troponins and ammonia, and the occurrence of occult blood on fecal examination.

  8. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    Science.gov (United States)

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  9. Interrogative pressure in simulated forensic interviews: the effects of negative feedback.

    Science.gov (United States)

    McGroarty, Allan; Baxter, James S

    2007-08-01

    Much experimental research on interrogative pressure has concentrated on the effects of leading questions, and the role of feedback in influencing responses in the absence of leading questions has been neglected by comparison. This study assessed the effect of negative feedback and the presence of a second interviewer on interviewee responding in simulated forensic interviews. Participants viewed a videotape of a crime, answered questions about the clip and were requestioned after receiving feedback. Compared with neutral feedback, negative feedback resulted in more response changes, higher reported state anxiety and higher ratings of interview difficulty. These results are consistent with Gudjonsson and Clark's (1986) model of interrogative suggestibility. The presence and involvement of a second interviewer did not significantly affect interviewee responding, although trait anxiety scores were elevated when a second interviewer was present. The theoretical and applied implications of these findings are considered.

  10. Technical specifications of variable speed motors for negative pressure control in hot cell area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Duk; Bang, H. S.; Cho, W. K

    2002-01-01

    Hot cells are the facilities for handling the high radioactive materials and various R and D activities are performed using hot cells. Therefore the control of air flow in hot cell area is very important technology and it is started with the variable speed motor(VSM) controlling the air handling system in that area. This report describes various technical aspects of VS motors and will be useful for understanding the practical technologies of VS motors and also for optimization of the negative pressure controls in hot cell area.

  11. Temporal evolution of atmosphere pressure plasma jets driven by microsecond pulses with positive and negative polarities

    Science.gov (United States)

    Shao, Tao; Yang, Wenjin; Zhang, Cheng; Fang, Zhi; Zhou, Yixiao; Schamiloglu, Edl

    2014-09-01

    Current-voltage characteristics, discharge images, and optical spectra of atmospheric pressure plasma jets (APPJs) are studied using a microsecond pulse length generator producing repetitive output pulses with different polarities. The experimental results show that the APPJs excited by the pulses with positive polarity have longer plume, faster propagation speed, higher power, and more excited species, such as \\text{N}2 , O, He, \\text{N}2+ , than that with the negatively excited APPJs. The images taken using an intensified charge-coupled device show that the APPJs excited by pulses with positive polarity are characterized by a bullet-like structure, while the APPJs excited by pulses with negative polarity are continuous. The propagation speed of the APPJs driven by a microsecond pulse length generator is about tens of km/s, which is similar to the APPJs driven by a kHz frequency sinusoidal voltage source. The analysis shows that the space charge accumulation effect plays an important role during the discharge. The transient enhanced electric field induced by the accumulated ions between the needle-like electrode and the nozzle in the APPJs excited by pulses with negative polarity enhances electron field emission from the cathode, which is illustrated by the bright line on the time-integrated images. This makes the shape of the APPJ excited using pulses with negative polarity different from the bullet-like shape of the APPJs excited by pulses with positive polarity.

  12. Flame Atmospheric Pressure Chemical Ionization Coupled with Negative Electrospray Ionization Mass Spectrometry for Ion Molecule Reactions.

    Science.gov (United States)

    Cheng, Sy-Chyi; Bhat, Suhail Muzaffar; Shiea, Jentaie

    2017-07-01

    Flame atmospheric pressure chemical ionization (FAPCI) combined with negative electrospray ionization (ESI) mass spectrometry was developed to detect the ion/molecule reactions (IMRs) products between nitric acid (HNO 3 ) and negatively charged amino acid, angiotensin I (AI) and angiotensin II (AII), and insulin ions. Nitrate and HNO 3 -nitrate ions were detected in the oxyacetylene flame, suggesting that a large quantity of nitric acid (HNO 3 ) was produced in the flame. The HNO 3 and negatively charged analyte ions produced by a negative ESI source were delivered into each arm of a Y-shaped stainless steel tube where they merged and reacted. The products were subsequently characterized with an ion trap mass analyzer attached to the exit of the Y-tube. HNO 3 showed the strongest affinity to histidine and formed (M histidine -H+HNO 3 ) - complex ions, whereas some amino acids did not react with HNO 3 at all. Reactions between HNO 3 and histidine residues in AI and AII resulted in the formation of dominant [M AI -H+(HNO 3 )] - and [M AII -H+(HNO 3 )] - ions. Results from analyses of AAs and insulin indicated that HNO 3 could not only react with basic amino acid residues, but also with disulfide bonds to form [M-3H+(HNO 3 ) n ] 3- complex ions. This approach is useful for obtaining information about the number of basic amino acid residues and disulfide bonds in peptides and proteins. Graphical Abstract ᅟ.

  13. Formation and Morphology Evolution of Anodic TiO2 Nanotubes under Negative Pressure

    International Nuclear Information System (INIS)

    Lu, Hongyan; Fan, Haowen; Jin, Rong; Chong, Bin; Shen, Xiaoping; Yan, Shuo; Zhu, Xufei

    2016-01-01

    Highlights: • Nernst equation is applied to explain electrochemical reactions during anodization. • Longer nanotubes were obtained under 0.02 MPa, as compared to atmospheric conditions. • The total anodizing current was separated into ionic current and electronic current. • Explanation for the particularity of nanotubes obtained under 0.02 MPa is presented. - Abstract: Anodic TiO 2 nanotubes (ATNTs) have attracted extensive interest in the past decade. ATNTs are generally fabricated by anodization of Ti foils under atmospheric conditions (0.1 MPa). To date, the growth kinetics of ATNTs remains unclear. Herein anodizations of Ti foils under negative pressure are designed to overcome this challenge. Longer nanotubes were fabricated under negative pressure, as compared to atmospheric conditions. Variations of the nanotube length and surface morphology of ATNTs provide evidences for oxygen bubble mould, in which the ionic current contributes to nanotube growth while the electronic current gives rise to the oxygen evolution. Nernst equation was firstly applied to simulate variations of electronic current and ionic current during anodization. The in-depth analysis of the morphology variations could help elucidate the formation mechanism, thus paving the way for the optimization of the synthesis process of ATNTs.

  14. Matching Biological Mesh and Negative Pressure Wound Therapy in Reconstructing an Open Abdomen Defect

    Directory of Open Access Journals (Sweden)

    Fabio Caviggioli

    2014-01-01

    Full Text Available Reconstruction of open abdominal defects is a clinical problem which general and plastic surgeons have to address in cooperation. We report the case of a 66-year-old man who presented an abdominal dehiscence after multiple laparotomies for a sigmoid-rectal adenocarcinoma that infiltrated into the abdominal wall, subsequently complicated by peritonitis and enteric fistula. A cutaneous dehiscence and an incontinent abdominal wall resulted after the last surgery. The abdominal wall was reconstructed using a biological porcine cross-linked mesh Permacol (Covidien Inc., Norwalk, CT. Negative Pressure Wound Therapy (NPWT, instead, was used on the mesh in order to reduce wound dimensions, promote granulation tissue formation, and obtain secondary closure of cutaneous dehiscence which was finally achieved with a split-thickness skin graft. Biological mesh behaved like a scaffold for the granulation tissue that was stimulated by the negative pressure. The biological mesh was rapidly integrated in the abdominal wall restoring abdominal wall continence, while the small dehiscence, still present in the central area, was subsequently covered with a split-thickness skin graft. The combination of these different procedures led us to solve this complicated case obtaining complete wound closure after less than 2 months.

  15. An Alternative Treatment Strategy for Complicated Chronic Wounds: Negative Pressure Therapy over Mesh Skin Graft

    Directory of Open Access Journals (Sweden)

    Michele Maruccia

    2017-01-01

    Full Text Available Extensive skin defect represents a real problem and major challenge in plastic and reconstructive surgery. On one hand, skin grafts offer a practical method to deal with skin defects despite their unsuitability for several complicated wounds. On the other hand, negative pressure wound therapy (NPWT, applied before skin grafting, promotes granulation tissue growth. The aim of the study is to evaluate the improvement in wound healing given by the merger of these two different approaches. We treated 23 patients for large wounds of multiple factors. Of these, 15 were treated with the application of V.A.C.® Therapy (KCI Medical S.r.l., Milan, Italy, in combination with skin grafts after a prior unsuccessful treatment of 4 weeks with mesh skin grafts and dressings. Another 8 were treated with only mesh skin graft. Pain reduction and wound area reduction were found statistically significant (p<0.0009, p<0.0001. Infection was resolved in almost all patients. According to our study, the use of the negative pressure wound therapy over mesh skin grafts is significantly effective especially in wounds resistant to conventional therapies, thereby improving the rate of skin graft take.

  16. Negative pressure therapy (vacuum for wound bed preparation among diabetic patients: case series

    Directory of Open Access Journals (Sweden)

    Marcus Castro Ferreira

    Full Text Available CONTEXT: Complications from diabetes mellitus affecting the lower limbs occur in 40 to 70% of such patients. Neuropathy is the main cause of ulceration and may be associated with vascular impairment. The wound evolves with necrosis and infection, and if not properly treated, amputation may be the end result. Surgical treatment is preferred in complex wounds without spontaneous healing. After debridement of the necrotic tissue, the wound bed needs to be prepared to receive a transplant of either a graft or a flap. Dressings can be used to prepare the wound bed, but this usually leads to longer duration of hospitalization. Negative pressure using a vacuum system has been proposed for speeding up the treatment. This paper had the objective of analyzing the effects of this therapy on wound bed preparation among diabetic patients. CASE SERIES: Eighty-four diabetic patients with wounds in their lower limbs were studied. A commercially available vacuum system was used for all patients after adequate debridement of necrotic tissues. For 65 patients, skin grafts completed the treatment and for the other 19, skin flaps were used. Wound bed preparation was achieved over an average time of 7.51 days for 65 patients and 10 days for 12 patients, and in only one case was not achieved. CONCLUSIONS: This experience suggests that negative pressure therapy may have an important role in wound bed preparation and as part of the treatment for wounds in the lower limbs of diabetic patients.

  17. A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

    Science.gov (United States)

    Scardulla, Francesco; Hu, Sijung; D'Acquisto, Leonardo; Pasta, Salvatore; Barrett, Laura; Blanos, Panagiotis; Yan, Liangwen

    2018-02-01

    In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 +/- 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with increases of +10mmHg and subsequently deflated by 10mmHg until reaching full deflation. The OEPS signals were captured using four wavelength illumination sources (i.e., green 525 nm, orange 595 nm, red 650 nm and IR 870 nm) on three different measuring sites, namely forefinger, radial artery and wrist. The implemented algorithm provides information on the instant when the SBP was reached and the signal is lost since the vessel is completely blocked. Similarly, it detected the signal resumption when the external pressure dropped below the SBP. The findings demonstrated a good correlation between the variation of the pressure and the corresponding OEPS signal with the most accurate result achieved in the fingertip among all wavelengths, with a temporal identification error of 8.07 %. Further studies will improve the clinical relevance on a cohort of patients diagnosed with hyper- or hypotension, in order to develop a wearable blood-pressure device.

  18. Increase in vagal activity during hypotensive lower-body negative pressure in humans

    DEFF Research Database (Denmark)

    Sander-Jensen, K; Mehlsen, J; Stadeager, C

    1988-01-01

    Progressive central hypovolemia is characterized by a normotensive, tachycardic stage followed by a reversible, hypotensive stage with slowing of the heart rate (HR). We investigated circulatory changes and arterial hormone concentrations in response to lower-body negative pressure (LBNP) in six...... volunteers before and after atropine administration. LBNP of 55 mmHg initially resulted in an increase in HR from 55 +/- 4 to 90 +/- 5 beats/min and decreases in mean arterial pressure (MAP) from 94 +/- 4 to 81 +/- 5 mmHg, in central venous pressure from 7 +/- 1 to -3 +/- 1 mmHg, and in cardiac output from 6.......1 +/- 0.5 to 3.7 +/- 0.11/min. Concomitantly, epinephrine and norepinephrine levels increased. After 8.2 +/- 2.3 min of LBNP, the MAP had decreased to 41 +/- 7 mmHg and HR had decreased to 57 +/- 3 beats/min. Vasopressin increased from 1.2 +/- 0.3 to 137 +/- 45 pg/ml and renin activity increased from 1...

  19. Negative pressure driven phase transformation in Sr doped SmCoO₃.

    Science.gov (United States)

    Arshad Farhan, M; Javed Akhtar, M

    2010-02-24

    Atomistic computer simulation techniques based on energy minimization procedures are utilized for the structural investigation of perovskite-type SmCoO(3). A reliable potential model is derived which reproduces both cubic as well as orthorhombic phases of SmCoO(3). We observe a negative chemical pressure induced structural phase transformation from distorted perovskite (orthorhombic) to perfect perovskite (cubic) due to the substitution of Sr(2 + ) at the Sm(3 + ) sites. However, external hydrostatic pressure shows isotropic compression and no pressure-induced structural transformation is observed up to 100 GPa. To maintain the electroneutrality of the system, charge compensation is through oxygen vacancies which results in the brownmillerite-type structure. A defect model is proposed, which is consistent with experimental results. The solution energies for divalent and trivalent cations are also calculated. These results show that the cations having ionic radii less than 0.75 Å will occupy the Co sites and those with ionic radii larger than 0.75 Å will substitute at the Sm sites.

  20. Negative pressure wound therapy versus standard wound care on quality of life: a systematic review.

    Science.gov (United States)

    Janssen, A H J; Mommers, E H H; Notter, J; de Vries Reilingh, T S; Wegdam, J A

    2016-03-01

    Negative pressure wound therapy (NPWT) is a widely accepted treatment modality for open or infected wounds. Premature ending of NPWT occasionally occurs due to negative effects on the quality of life (QoL), however, the actual impact on QoL is unknown. The aim of this review is to analyse the effect of NPWT versus standard wound care (SWC) on QoL when used for the treatment of open or infected wounds. A systematic literature search in a range of databases (PubMed, CINAHL, Medline, Web of Science, Science Direct Freedom Collection, SwetsWise, PSYCArticles and Infrotrac Custom Journals) using the following search terms; 'standard wound care', 'wound dressing', 'dressing', 'treatment', OR 'negative pressure wound therapy [MESH]', OR 'vacuum assisted closure' AND 'quality of life [MESH]', 'patient-satisfaction', OR 'experiences' was performed. Methodological quality was assessed using the methodological index for non-randomised studies (MINORS) checklist. There were 42 studies identified, five matched the inclusion criteria: two randomised clinical trials (RCTs), one clinical comparative study, one exploratory prospective cohort study and one quasi experimental pilot study. Median MINORS-score was 75% (58%-96%). There were seven different questionnaires used to measure QoL or a subsidiary outcome. QoL in the NPWT group was lower in the first week, though no difference in QoL was observed thereafter. This systematic review observed that QoL improved at the end of therapy independent of which therapy was used. NPWT led to a lower QoL during the first week of treatment, possible due to aniexty, after which a similar or better QoL was reported when compared with SWC. It could be suggested that NPWT might be associated with increased anxiety. All authors of this publication have received no financial support or have personal interests conflicting with the objectivity of this manuscript.

  1. Magnetosphere and ionosphere response to a positive-negative pulse pair of solar wind dynamic pressure

    Science.gov (United States)

    Tian, A.; Degeling, A. W.

    2017-12-01

    Simulations and observations had shown that single positive/negative solar wind dynamic pressure pulse would excite geomagnetic impulsive events along with ionosphere and/or magnetosphere vortices which are connected by field aligned currents(FACs). In this work, a large scale ( 9min) magnetic hole event in solar wind provided us with the opportunity to study the effects of positive-negative pulse pair (△p/p 1) on the magnetosphere and ionosphere. During the magnetic hole event, two traveling convection vortices (TCVs, anti-sunward) first in anticlockwise then in clockwise rotation were detected by geomagnetic stations located along the 10:30MLT meridian. At the same time, another pair of ionospheric vortices azimuthally seen up to 3 MLT first in clockwise then in counter-clockwise rotation were also appeared in the afternoon sector( 14MLT) and centered at 75 MLAT without obvious tailward propagation feature. The duskside vortices were also confirmed in SuperDARN radar data. We simulated the process of magnetosphere struck by a positive-negative pulse pair and it shows that a pair of reversed flow vortices in the magnetosphere equatorial plane appeared which may provide FACs for the vortices observed in ionosphere. Dawn dusk asymmetry of the vortices as well as the global geomagnetism perturbation characteristics were also discussed.

  2. Supine exercise during lower body negative pressure effectively simulates upright exercise in normal gravity

    Science.gov (United States)

    Murthy, G.; Watenpaugh, D. E.; Ballard, R. E.; Hargens, A. R.

    1994-01-01

    Exercise within a lower body negative pressure (LBNP) chamber in supine posture was compared with similar exercise against Earth's gravity (without LBNP) in upright posture in nine healthy male volunteers. We measured footward force with a force plate, pressure in soleus and tibialis anterior muscles of the leg with transducer-tipped catheters, calf volume by strain gauge plethysmography, heart rate, and systolic and diastolic blood pressures during two conditions: 1) exercise in supine posture within an LBNP chamber during 100-mmHg LBNP (exercise-LBNP) and 2) exercise in upright posture against Earth's gravity without LBNP (exercise-1 G). Subjects exercised their ankle joints (dorsi- and plantarflexions) for 5 min during exercise-LBNP and for 5 min during exercise-1 G. Mean footward force produced during exercise-LBNP (743 +/- 37 N) was similar to that produced during exercise-1 G (701 +/- 24 N). Peak contraction pressure in the antigravity soleus muscle during exercise-LBNP (115 +/- 10 mmHg) was also similar to that during exercise-1 G (103 +/- 13 mmHg). Calf volume increased significantly by 3.3 +/- 0.5% during exercise-LBNP compared with baseline values. Calf volume did not increase significantly during exercise-1 G. Heart rate was significantly higher during exercise-LBNP (99 +/- 5 beats/min) than during exercise-1 G (81 +/- 3 beats/min). These results indicate that exercise in supine posture within an LBNP chamber can produce similar musculoskeletal stress in the legs and greater systemic cardiovascular stress than exercise in the upright posture against Earth's gravity.

  3. The effects of superimposed tilt and lower body negative pressure on anterior and posterior cerebral circulations.

    Science.gov (United States)

    Tymko, Michael M; Rickards, Caroline A; Skow, Rachel J; Ingram-Cotton, Nathan C; Howatt, Michael K; Day, Trevor A

    2016-09-01

    Steady-state tilt has no effect on cerebrovascular reactivity to increases in the partial pressure of end-tidal carbon dioxide (PETCO2). However, the anterior and posterior cerebral circulations may respond differently to a variety of stimuli that alter central blood volume, including lower body negative pressure (LBNP). Little is known about the superimposed effects of head-up tilt (HUT; decreased central blood volume and intracranial pressure) and head-down tilt (HDT; increased central blood volume and intracranial pressure), and LBNP on cerebral blood flow (CBF) responses. We hypothesized that (a) cerebral blood velocity (CBV; an index of CBF) responses during LBNP would not change with HUT and HDT, and (b) CBV in the anterior cerebral circulation would decrease to a greater extent compared to posterior CBV during LBNP when controlling PETCO2 In 13 male participants, we measured CBV in the anterior (middle cerebral artery, MCAv) and posterior (posterior cerebral artery, PCAv) cerebral circulations using transcranial Doppler ultrasound during LBNP stress (-50 mmHg) in three body positions (45°HUT, supine, 45°HDT). PETCO2 was measured continuously and maintained at constant levels during LBNP through coached breathing. Our main findings were that (a) steady-state tilt had no effect on CBV responses during LBNP in both the MCA (P = 0.077) and PCA (P = 0.583), and (b) despite controlling for PETCO2, both the MCAv and PCAv decreased by the same magnitude during LBNP in HUT (P = 0.348), supine (P = 0.694), and HDT (P = 0.407). Here, we demonstrate that there are no differences in anterior and posterior circulations in response to LBNP in different body positions. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  4. Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

    Science.gov (United States)

    Baisch, F.; Beck, L.; Blomqvist, G.; Wolfram, G.; Drescher, J.; Rome, J. L.; Drummer, C.

    2000-01-01

    BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

  5. Validation of lower body negative pressure as an experimental model of hemorrhage

    Science.gov (United States)

    Shade, Robert E.; Muniz, Gary W.; Bauer, Cassondra; Goei, Kathleen A.; Pidcoke, Heather F.; Chung, Kevin K.; Cap, Andrew P.; Convertino, Victor A.

    2013-01-01

    Lower body negative pressure (LBNP), a model of hemorrhage (Hem), shifts blood to the legs and elicits central hypovolemia. This study compared responses to LBNP and actual Hem in sedated baboons. Arterial pressure, pulse pressure (PP), central venous pressure (CVP), heart rate, stroke volume (SV), and +dP/dt were measured. Hem steps were 6.25%, 12.5%, 18.75%, and 25% of total estimated blood volume. Shed blood was returned, and 4 wk after Hem, the same animals were subjected to four LBNP levels which elicited equivalent changes in PP and CVP observed during Hem. Blood gases, hematocrit (Hct), hemoglobin (Hb), plasma renin activity (PRA), vasopressin (AVP), epinephrine (EPI), and norepinephrine (NE) were measured at baseline and maximum Hem or LBNP. LBNP levels matched with 6.25%, 12.5%, 18.75%, and 25% hemorrhage were −22 ± 6, −41 ± 7, −54 ± 10, and −71 ± 7 mmHg, respectively (mean ± SD). Hemodynamic responses to Hem and LBNP were similar. SV decreased linearly such that 25% Hem and matching LBNP caused a 50% reduction in SV. Hem caused a decrease in Hct, Hb, and central venous oxygen saturation (ScvO2). In contrast, LBNP increased Hct and Hb, while ScvO2 remained unchanged. Hem caused greater elevations in AVP and NE than LBNP, while PRA, EPI, and other hematologic indexes did not differ between studies. These results indicate that while LBNP does not elicit the same effect on blood cell loss as Hem, LBNP mimics the integrative cardiovascular response to Hem, and validates the use of LBNP as an experimental model of central hypovolemia associated with Hem. PMID:24356525

  6. The use of isoprene as a novel dopant in negative ion atmospheric pressure photoionization mass spectrometry coupled to high-performance liquid chromatography.

    Science.gov (United States)

    Dousty, Faezeh; O'Brien, Rob

    2015-06-15

    As in the case with positive ion atmospheric pressure photoionization (PI-APPI), the addition of dopants significantly improves the sensitivity of negative ion APPI (NI-APPI). However, the research on dopant-assisted-NI-APPI has been quite limited compared to the studies on dopant-assisted PI-APPI. This work presents the potential of isoprene as a novel dopant for NI-APPI. Thirteen compounds, possessing suitable gas-phase ion energetic properties in order to make stable negative ions, were selected. Dopants were continuously introduced into a tee junction prior to the ion source through a fused-silica capillary, while analytes were directly injected into the same tee. Then both were mixed with the continuous solvent from high-performance liquid chromatography (HPLC), nebulized, and entered the source. The nebulized stream was analyzed by APPI tandem quadrupole mass spectrometry in the negative ion mode. The results obtained using isoprene were compared with those obtained by using toluene as a dopant and dopant-free NI-APPI. Isoprene enhanced the ionization intensities of the studied compounds, which were found to be comparable and, in some cases, more effective than toluene. The mechanisms leading to the observed set of negative analyte ions were also discussed. Because in NI-APPI, thermal electrons, which are produced during the photoionization of a dopant, are considered the main reagent ions, both isoprene and toluene promoted the ionization of analytes through the same mechanisms, as expected. Isoprene was shown to perform well as a novel dopant for NI-APPI. Isoprene has a high photoabsorption cross section in the VUV region; therefore, its photoionization leads to a highly effective production of thermal electrons, which further promotes the ionization of analytes. In addition, isoprene is environmentally benign and less toxic compared to currently used dopants. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Diabetic foot wounds: the value of negative pressure wound therapy with instillation.

    Science.gov (United States)

    Dalla Paola, Luca

    2013-12-01

    Chronic wounds such as diabetic foot wounds are a tremendous burden to the health care system and often require a multidisciplinary approach to prevent amputations. Advanced technologies such as negative pressure wound therapy (NPWT) and bioengineered tissues have been successfully used in the treatment of these types of complex wounds. However, the introduction of NPWT with instillation (NPWTi) has provided an alternative treatment for treating complex and difficult-to-heal wounds. This article provides an overview of NPWT and the new NPWTi system and describes preliminary experience using NPWTi on patients with complicated infected diabetic foot wounds after surgical debridement and in a multidisciplinary setting. © 2013 The Author. International Wound Journal © 2013 John Wiley & Sons Ltd and Medicalhelplines.com Inc.

  8. Electrical admittance for filling of the heart during lower body negative pressure in humans

    DEFF Research Database (Denmark)

    Cai, Yujia; Holm, S; Jenstrup, M

    2000-01-01

    To evaluate whether electrical admittance of intracellular water is applicable for monitoring filling of the heart, we determined the difference in intracellular water in the thorax (Thorax(ICW)), measured as the reciprocal value of the electrical impedance for the thorax at 1.5 and 100 kHz during...... lower body negative pressure (LBNP) in humans. Changes in Thorax(ICW) were compared with positron emission tomography-determined C(15)O-labeled erythrocytes over the heart. During -40 mmHg LBNP, the blood volume of the heart decreased by 21 +/- 3% as the erythrocyte volume was reduced by 20 +/- 2.......6 to 40.9 +/- 5.0 S. 10(-4); P = 0.08). The correlation between Thorax(ICW) and heart erythrocyte volume was 0.84 (P electrical admittance of intracellular water can be applied to evaluate changes in blood volume of the heart during LBNP in humans....

  9. Negative pressure pulmonary oedema following use of ProSeal LMA

    Directory of Open Access Journals (Sweden)

    Richa Jain

    2013-01-01

    Full Text Available Negative pressure pulmonary oedema (NPPO is a life threatening condition, manifested due to upper airway obstruction in a spontaneously breathing patient. Upper airway obstruction caused by classic laryngeal mask airway (cLMA and ProSeal laryngeal mask airway (PLMA has been reported, and NPPO has also been reported following the use of cLMA. Search of literature did not confirm NPPO following the use of PLMA. We encountered a female patient of NPPO scheduled for incision and drainage of an abscess who had signs of airway obstruction following PLMA insertion. Multiple attempts were made to get patent airway without success. PLMA was replaced with endotracheal tube following which pink frothy secretion appeared in breathing circuit. Patient was managed successfully with ICU care.

  10. Negative ion molecule reactions of WF6: evidence for a pressure dependent branching ratio

    International Nuclear Information System (INIS)

    Viggiano, A.A.; Paulson, J.F.

    1984-01-01

    Rate coefficients have been measured in a selected ion flow tube (SIFT) for reactions of several negative ions with WF 6 . With the exception of SF - 5 , all the reactant ions studied having an electron detachment energy less than 3.36 eV reacted rapidly by charge exchange. SF - 5 transferred a fluoride ion producing WF - 7 . Ions with detachment energies greater than 3.36 eV associated rapidly with WF - 6 . Br - , with a detachment energy of 3.36 eV, reacted with WF 6 both by ion-neutral association and by charge exchange. The branching ratio for these two channels was found to depend on temperature and pressure. All these data indicate that the electron affinity of WF 6 is nearly equal to that of Br

  11. Negative-Pressure Cavitation Extraction of Secoisolariciresinol Diglycoside from Flaxseed Cakes

    Directory of Open Access Journals (Sweden)

    Hao Tian

    2015-06-01

    Full Text Available The negative-pressure cavitation extraction (NPCE technique was applied firstly to extract secoisolariciresinol diglucoside (SDG from flaxseed cakes. The significant extraction parameters were screened by fractional factorial design (FFD. The optimal parameters were determined using the central composite design (CCD with the two variables, NaOH amount and the liquid/solid ratio. The conditions of the extraction were optimized by using response surface methodology (RSM. Under the optimal conditions, the extraction yield and the extraction purity of SDG was 16.25 mg/g and 3.86%, respectively. The efficiency of NPCE was compared with that of conventional extraction methods. Our results demonstrated that NPCE was comparable to the well-known ultrasound-assisted extraction in term of extraction yield and purity. This extraction technique has advantages of less time-consuming, low solvent usage and high throughput capability.

  12. Negative pressure wound therapy in pediatric surgery: How and when to use.

    Science.gov (United States)

    de Jesus, Lisieux Eyer; Martins, Alana Bandeira; Oliveira, Pablo Baptista; Gomes, Fernanda; Leve, Thais; Dekermacher, Samuel

    2018-04-01

    Negative pressure wound therapy (NPWT) has been widely adopted to treat laparostomy, abdominal compartment syndrome (ACS) and complicated wounds associated with tissue loss. The method presents specific aspects, advantages and indications in Pediatrics. Our aim is to review the evidence available about NPWT in children. Active search for papers about NPWT in Pediatric patients. Papers referring to orthopedic problems, wound complications after Cardiac Surgery or burns were excluded. The method shows good results to treat ACS, complicated wounds and abdominal wall malformations in neonates, including prematures. Periwound skin protection, monitoring of fluid losses and fine tuning of negative pressure levels according to age are necessary. Less pain, quicker recovery, less frequent dressing changes, possible recovery of exposed surgical hardware, granulation and shrinkage of the wound are advantages of the method over other kinds of dressing. NPWT is contraindicated over blood vessels and exposed nerves. Debridement is needed before usage over necrotic areas. Enteric fistulae are not contraindications. Complications are rare, mainly foam retention and dermatitis/skin maceration. The possibility of fistulae being caused by NPWT remains debatable. NPWT is widely used in Pediatrics, including neonates and premature, but the evidence available about the method is scarce and low quality. Complications are uncommon and mostly manageable. A possible causal relationship between NPWY and enteric fistula remains unclear. Adult devices and parameters have been adapted to children's use. Extra care is needed to protect the delicate tissues of Pediatric patients. Comparative research to define differential costs, indications and advantages of the method, specific indications and limits of NWTP in Pediatrics is needed. Review. IV. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Intrarectal negative pressure system in the management of open abdomen with colorectal fistula: A case report☆

    Science.gov (United States)

    Yetişir, Fahri; Salman, A. Ebru; Mamedov, Ruslan; Aksoy, Mustafa; Yalcin, Abdussamet; Kayaalp, Cüneyt

    2014-01-01

    INTRODUCTION To present the management of open abdomen with colorectal fistula by application of intrarectal negative pressure system (NPS) in addition to abdominal NPS. PRESENTATION OF CASE Twenty-year old man had a history of injuries by a close-range gunshot to the abdomen eight days ago and he had been treated by bowel repairs, resections, jejunal anastomosis and Hartman's procedure. He was referred to our center after deterioration, evisceration with open abdomen and enteric fistula in septic shock. There were edematous, fibrinous bowels and large multiple fistulas from the edematous rectal stump. APACHE II, Mannheim Peritoneal Index and Björck scores were 18, 33 and 3, respectively (expected mortality 100%). After intensive care for 5 days, he was treated by abdominal and intrarectal NPS. NPS repeated for 5 times and the fistula was recovered on day 18 completely. Fascial closure was facilitated with a dynamic abdominal closure system (ABRA) and he was discharged on day 33 uneventfully. There was no herniation and any other problem after 12 months follow-up. DISCUSSION Management of fistula in OA can be extremely challenging. Floating stoma, fistula VAC, nipple VAC, ring and silo VAC, fistula intubation systems are used for isolation of the enteric effluent from OA. Several biologic dressings such as acellular dermal matrix, pedicled flaps have been used to seal the fistula opening with various success. Resection of the involved enteric loop and a new anastomosis of the intestine is very hard and rarely possible. In all of these reports, usually patients are left to heal with a giant hernia. In contrast to this, there is no hernia in our case during one year follow up period. CONCLUSION Combination of intra and extra luminal negative pressure systems and ABRA is a safe and successful method to manage open abdomen with colorectal fistula. PMID:24584042

  14. Intrarectal negative pressure system in the management of open abdomen with colorectal fistula: A case report.

    Science.gov (United States)

    Yetişir, Fahri; Salman, A Ebru; Mamedov, Ruslan; Aksoy, Mustafa; Yalcin, Abdussamet; Kayaalp, Cüneyt

    2014-01-01

    To present the management of open abdomen with colorectal fistula by application of intrarectal negative pressure system (NPS) in addition to abdominal NPS. Twenty-year old man had a history of injuries by a close-range gunshot to the abdomen eight days ago and he had been treated by bowel repairs, resections, jejunal anastomosis and Hartman's procedure. He was referred to our center after deterioration, evisceration with open abdomen and enteric fistula in septic shock. There were edematous, fibrinous bowels and large multiple fistulas from the edematous rectal stump. APACHE II, Mannheim Peritoneal Index and Björck scores were 18, 33 and 3, respectively (expected mortality 100%). After intensive care for 5 days, he was treated by abdominal and intrarectal NPS. NPS repeated for 5 times and the fistula was recovered on day 18 completely. Fascial closure was facilitated with a dynamic abdominal closure system (ABRA) and he was discharged on day 33 uneventfully. There was no herniation and any other problem after 12 months follow-up. Management of fistula in OA can be extremely challenging. Floating stoma, fistula VAC, nipple VAC, ring and silo VAC, fistula intubation systems are used for isolation of the enteric effluent from OA. Several biologic dressings such as acellular dermal matrix, pedicled flaps have been used to seal the fistula opening with various success. Resection of the involved enteric loop and a new anastomosis of the intestine is very hard and rarely possible. In all of these reports, usually patients are left to heal with a giant hernia. In contrast to this, there is no hernia in our case during one year follow up period. Combination of intra and extra luminal negative pressure systems and ABRA is a safe and successful method to manage open abdomen with colorectal fistula. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Comparison of compensatory reserve during lower-body negative pressure and hemorrhage in nonhuman primates.

    Science.gov (United States)

    Hinojosa-Laborde, Carmen; Howard, Jeffrey T; Mulligan, Jane; Grudic, Greg Z; Convertino, Victor A

    2016-06-01

    Compensatory reserve was measured in baboons (n = 13) during hemorrhage (Hem) and lower-body negative pressure (LBNP) using a machine-learning algorithm developed to estimate compensatory reserve by detecting reductions in central blood volume during LBNP. The algorithm calculates compensatory reserve index (CRI) from normovolemia (CRI = 1) to cardiovascular decompensation (CRI = 0). The hypothesis was that Hem and LBNP will elicit similar CRI values and that CRI would have higher specificity than stroke volume (SV) in predicting decompensation. Blood was removed in four steps: 6.25%, 12.5%, 18.75%, and 25% of total blood volume. Four weeks after Hem, the same animals were subjected to four levels of LBNP that was matched on the basis of their central venous pressure. Data (mean ± 95% confidence interval) indicate that CRI decreased (P AUC in Hem (0.94 vs. 0.84) and LBNP (0.94 vs. 0.92). These data support the hypothesis that Hem and LBNP elicited the same CRI response, suggesting that measurement of compensatory reserve is superior to SV as a predictor of cardiovascular decompensation.

  16. Development of micropump-actuated negative pressure pinched injection for parallel electrophoresis on array microfluidic chip.

    Science.gov (United States)

    Li, Bowei; Jiang, Lei; Xie, Hua; Gao, Yan; Qin, Jianhua; Lin, Bingcheng

    2009-09-01

    A micropump-actuated negative pressure pinched injection method is developed for parallel electrophoresis on a multi-channel LIF detection system. The system has a home-made device that could individually control 16-port solenoid valves and a high-voltage power supply. The laser beam is excitated and distributes to the array separation channels for detection. The hybrid Glass-PDMS microfluidic chip comprises two common reservoirs, four separation channels coupled to their respective pneumatic micropumps and two reference channels. Due to use of pressure as a driving force, the proposed method has no sample bias effect for separation. There is only one high-voltage supply needed for separation without relying on the number of channels, which is significant for high-throughput analysis, and the time for sample loading is shortened to 1 s. In addition, the integrated micropumps can provide the versatile interface for coupling with other function units to satisfy the complicated demands. The performance is verified by separation of DNA marker and Hepatitis B virus DNA samples. And this method is also expected to show the potential throughput for the DNA analysis in the field of disease diagnosis.

  17. Tolerance of Lower Body Negative Pressure (LBNP) in endurance runners, weightlifters, swimmers and nonathletes

    Science.gov (United States)

    1980-01-01

    Thirteen endurance runners (R), 12 weightlifters (WL), 12 swimmers (SW) and 10 nonathletes (NA) were tested for their tolerance of lower body negative pressure (LBNP) in consecutive 5 minute stages at -20, -30, -40, -50 and -60 torr. Each subject also performed an exercise test on a bicycle ergometer with progressive workloads to exhaustion to determined aerobic capacity. The R had a much higher aerobic capacity than any of the other groups, but a significantly lower LBNP tolerance. While responses in heart rate and pulse pressure were quite similar in all 4 groups, the rate of increase in leg volume relative to LBNP stress (leg compliance, LC) was considerably greater in R than in the other athletes and NA. The greater LC in R could be attributed not only to a more rapid shift of blood to the lower extremities but also to a greater tendency for edema formation, both contributing to a more rapid loss in effective central blood volume for a given LBNP stress. These results substantiate earlier observations which led to the conclusion that endurance running is not advisable as a training regimen for astronauts.

  18. Preparation of a long-alkyl-chain-based hybrid monolithic column with mixed-mode interactions using a "one-pot" process for pressurized capillary electrochromatography.

    Science.gov (United States)

    Lyu, Haixia; Zhao, Heqing; Qin, Wenfei; Xie, Zenghong

    2017-12-01

    A simple "one-pot" approach for the preparation of a new vinyl-functionalized organic-inorganic hybrid monolithic column is described. In this improved method, the hydrolyzed alkoxysilanes of tetramethoxysilane and triethoxyvinylsilane were used as precursors for the synthesis of a silica-based monolith, while 1-hexadecene and sodium ethylenesulfonate were used as vinyl functional monomers along with azobisisobutyronitrile as an initiator. The effects of reaction temperature, urea content, and composition of organic monomers on the column properties (e.g. morphology, mechanical stability, and chromatographic performance) were investigated. The monolithic column was used for the separation of neutral solutes by reversed-phase pressurized capillary. Furthermore, the monolith can separate various aromatic amines, which indicated its excellent cation-exchange capability and hydrophobic interactions. The baseline separation of the aromatic amines was obtained with a column efficiency of up to 78 000 plates/m. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. On Numerical Methods for Including the Effect of Capillary Pressure Forces on Two-phase, Immiscible Flow in a Layered Porous Medium

    Energy Technology Data Exchange (ETDEWEB)

    Ersland, B.G.

    1996-05-01

    This mathematical doctoral thesis contains the theory, algorithms and numerical simulations for a heterogeneous oil reservoir. It presents the equations, which apply to immiscible and incompressible two-phase fluid flow in the reservoir, including the effect of capillary pressure forces, and emphasises in particular the interior boundary conditions at the interface between two sediments. Two different approaches are discussed. The first approach is to decompose the computational domain along the interior boundary and iterate between the subdomains until mass balance is achieved. The second approach accounts for the interior boundary conditions in the basis in which the solution is expanded, the basis being discontinuous over the interior boundaries. An overview of the construction of iterative solvers for partial differential equations by means of Schwartz methods is given, and the algorithm for local refinement with Schwartz iterations as iterative solver is described. The theory is then applied to a core plug problem in one and two space dimensions and the results of different methods compared. A general description is given of the computer simulation model, which is implemented in C++. 64 refs., 49 figs., 7 tabs.

  20. Effect of aerobic capacity on Lower Body Negative Pressure (LBNP) tolerance in females

    Science.gov (United States)

    Moore, Alan D., Jr.; Fortney, Suzanne M.; Siconolfi, Steven F.

    1993-01-01

    This investigation determined whether a relationship exists in females between: (1) aerobic capacity and Lower Body Negative Pressure (LBNP); and (2) aerobic capacity and change in LBNP tolerance induced by bed rest. Nine females, age 27-47 (34.6 plus or minus 6.0 (Mean plus or minus SD)), completed a treadmill-graded exercise test to establish aerobic capacity. A presyncopal-limited LBNP test was performed prior to and after 13 days of bed rest at a 6 deg head-down tilt. LBNP tolerance was quantified as: (1) the absolute level of negative pressure (NP) tolerated for greater than or equal to 60 sec; and (2) Luft's Cumulative Stress Index (CSI). Aerobic capacity was 33.3 plus or minus 5.0 mL/kg/min and ranged from 25.7 to 38.7. Bed rest was associated with a decrease in NP tolerance (-9.04 1.6 kPa(-67.8 plus or minus 12.0 mmHg) versus -7.7 1.1 kPa(-57.8 plus or minus 8.33 mmHg); p = 0.028) and in CSI (99.4 27.4 kPa min(745.7 plus or minus 205.4 mmHg min) versus 77.0 16.9 kPa min (577.3 plus or minus mmHg min); p = 0.008). The correlation between aerobic capacity and absolute NP or CSI pre-bed rest did not differ significantly from zero (r = -0.56, p = 0.11 for NP; and r = -0.52, p = 0.16 for CSI). Also, no significant correlation was observed between aerobic and pre- to post-rest change for absolute NP tolerance (r = -0.35, p = 0.35) or CSI (r = -0.32, p = 0.40). Therefore, a significant relationship does not exist between aerobic capacity and orthostatic function or change in orthostatic function induced by bed rest.

  1. Skin graft fixation in severe burns: use of topical negative pressure.

    Science.gov (United States)

    Kamolz, L P; Lumenta, D B; Parvizi, D; Wiedner, M; Justich, I; Keck, M; Pfurtscheller, K; Schintler, M

    2014-09-30

    Over the last 50 years, the evolution of burn care has led to a significant decrease in mortality. The biggest impact on survival has been the change in the approach to burn surgery. Early excision and grafting has become a standard of care for the majority of patients with deep burns; the survival of a given patient suffering from major burns is invariably linked to the take rate and survival of skin grafts. The application of topical negative pressure (TNP) therapy devices has demonstrated improved graft take in comparison to conventional dressing methods alone. The aim of this study was to analyze the impact of TNP therapy on skin graft fixation in large burns. In all patients, we applied TNP dressings covering a %TBSA of >25. The following parameters were recorded and documented using BurnCase 3D: age, gender, %TBSA, burn depth, hospital length-of-stay, Baux score, survival, as well as duration and incidence of TNP dressings. After a burn depth adapted wound debridement, coverage was simultaneously performed using split-thickness skin grafts, which were fixed with staples and covered with fatty gauzes and TNP foam. The TNP foam was again fixed with staples to prevent displacement and finally covered with the supplied transparent adhesive film. A continuous subatmospheric pressure between 75-120 mm Hg was applied (VAC®, KCI, Vienna, Austria). The first dressing change was performed on day 4. Thirty-six out of 37 patients, suffering from full thickness burns, were discharged with complete wound closure; only one patient succumbed to their injuries. The overall skin graft take rate was over 95%. In conclusion, we consider that split thickness skin graft fixation by TNP is an efficient method in major burns, notably in areas with irregular wound surfaces or subject to movement (e.g. joint proximity), and is worth considering for the treatment of aged patients.

  2. Comparison of compensatory reserve during lower-body negative pressure and hemorrhage in nonhuman primates

    Science.gov (United States)

    Howard, Jeffrey T.; Mulligan, Jane; Grudic, Greg Z.; Convertino, Victor A.

    2016-01-01

    Compensatory reserve was measured in baboons (n = 13) during hemorrhage (Hem) and lower-body negative pressure (LBNP) using a machine-learning algorithm developed to estimate compensatory reserve by detecting reductions in central blood volume during LBNP. The algorithm calculates compensatory reserve index (CRI) from normovolemia (CRI = 1) to cardiovascular decompensation (CRI = 0). The hypothesis was that Hem and LBNP will elicit similar CRI values and that CRI would have higher specificity than stroke volume (SV) in predicting decompensation. Blood was removed in four steps: 6.25%, 12.5%, 18.75%, and 25% of total blood volume. Four weeks after Hem, the same animals were subjected to four levels of LBNP that was matched on the basis of their central venous pressure. Data (mean ± 95% confidence interval) indicate that CRI decreased (P < 0.001) from baseline during Hem (0.69 ± 0.10, 0.57 ± 0.09, 0.36 ± 0.10, 0.16 ± 0.08, and 0.08 ± 0.03) and LBNP (0.76 ± 0.05, 0.66 ± 0.08, 0.36 ± 0.13, 0.23 ± 0.11, and 0.14 ± 0.09). CRI was not different between Hem and LBNP (P = 0.20). Linear regression analysis between Hem CRI and LBNP CRI revealed a slope of 1.03 and a correlation coefficient of 0.96. CRI exhibited greater specificity than SV in both Hem (92.3 vs. 82.1) and LBNP (94.8 vs. 83.1) and greater ROC AUC in Hem (0.94 vs. 0.84) and LBNP (0.94 vs. 0.92). These data support the hypothesis that Hem and LBNP elicited the same CRI response, suggesting that measurement of compensatory reserve is superior to SV as a predictor of cardiovascular decompensation PMID:27030667

  3. Paramecium swimming in capillary tube

    Science.gov (United States)

    Jana, Saikat; Um, Soong Ho; Jung, Sunghwan

    2012-04-01

    Swimming organisms in their natural habitat need to navigate through a wide range of geometries and chemical environments. Interaction with boundaries in such situations is ubiquitous and can significantly modify the swimming characteristics of the organism when compared to ideal laboratory conditions. We study the different patterns of ciliary locomotion in glass capillaries of varying diameter and characterize the effect of the solid boundaries on the velocities of the organism. Experimental observations show that Paramecium executes helical trajectories that slowly transition to straight lines as the diameter of the capillary tubes decreases. We predict the swimming velocity in capillaries by modeling the system as a confined cylinder propagating longitudinal metachronal waves that create a finite pressure gradient. Comparing with experiments, we find that such pressure gradient considerations are necessary for modeling finite sized ciliary organisms in restrictive geometries.

  4. Cost study of dermal substitutes and topical negative pressure in the surgical treatment of burns.

    Science.gov (United States)

    Hop, M Jenda; Bloemen, Monica C T; van Baar, Margriet E; Nieuwenhuis, Marianne K; van Zuijlen, Paul P M; Polinder, Suzanne; Middelkoop, Esther

    2014-05-01

    A recently performed randomised controlled trial investigated the clinical effectiveness of dermal substitutes (DS) and split skin grafts (SSG) in combination with topical negative pressure (TNP) in the surgical treatment of burn wounds. In the current study, medical and non-medical costs were investigated, to comprehensively assess the benefits of this new treatment. The primary outcome was mean total costs of the four treatment strategies: SSG with or without DS, and with or without TNP. Costs were studied from a societal perspective. Findings were evaluated in light of the clinical effects on scar elasticity. Eighty-six patients were included. Twelve months post-operatively, highest elasticity was measured in scars treated with DS and TNP (p=0.027). The initial cost price of treatment with DS and TNP was €2912 compared to treatment with SSG alone €1703 (ptreatment contributed maximal 7% to the total costs and total costs varied widely within and between groups, but were not significantly different. Therefore, in the selection of the most optimal type of surgical intervention, cost considerations should not play an important role. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  5. Evidence for negative effects of elevated intra-abdominal pressure on pulmonary mechanics and oxidative stress.

    Science.gov (United States)

    Davarcı, I; Karcıoğlu, M; Tuzcu, K; İnanoğlu, K; Yetim, T D; Motor, S; Ulutaş, K T; Yüksel, R

    2015-01-01

    To compare the effects of pneumoperitoneum on lung mechanics, end-tidal CO2 (ETCO2), arterial blood gases (ABG), and oxidative stress markers in blood and bronchoalveolar lavage fluid (BALF) during laparoscopic cholecystectomy (LC) by using lung-protective ventilation strategy. Forty-six patients undergoing LC and abdominal wall hernia (AWH) surgery were assigned into 2 groups. Measurements and blood samples were obtained before, during pneumoperitoneum, and at the end of surgery. BALF samples were obtained after anesthesia induction and at the end of surgery. Peak inspiratory pressure, ETCO2, and pCO2 values at the 30th minute were significantly increased, while there was a significant decrease in dynamic lung compliance, pH, and pO2 values in LC group. In BALF samples, total oxidant status (TOS), arylesterase, paraoxonase, and malondialdehyde levels were significantly increased; the glutathione peroxidase levels were significantly decreased in LC group. The serum levels of TOS and paraoxonase were significantly higher at the end of surgery in LC group. In addition, arylesterase level in the 30th minute was increased compared to baseline. Serum paraoxonase level at the end of surgery was significantly increased when compared to AWH group. Our study showed negative effects of pneumoperitoneum in both lung and systemic levels despite lung-protective ventilation strategy.

  6. Evidence for Negative Effects of Elevated Intra-Abdominal Pressure on Pulmonary Mechanics and Oxidative Stress

    Directory of Open Access Journals (Sweden)

    I. Davarcı

    2015-01-01

    Full Text Available Objective. To compare the effects of pneumoperitoneum on lung mechanics, end-tidal CO2 (ETCO2, arterial blood gases (ABG, and oxidative stress markers in blood and bronchoalveolar lavage fluid (BALF during laparoscopic cholecystectomy (LC by using lung-protective ventilation strategy. Materials and Methods. Forty-six patients undergoing LC and abdominal wall hernia (AWH surgery were assigned into 2 groups. Measurements and blood samples were obtained before, during pneumoperitoneum, and at the end of surgery. BALF samples were obtained after anesthesia induction and at the end of surgery. Results. Peak inspiratory pressure, ETCO2, and pCO2 values at the 30th minute were significantly increased, while there was a significant decrease in dynamic lung compliance, pH, and pO2 values in LC group. In BALF samples, total oxidant status (TOS, arylesterase, paraoxonase, and malondialdehyde levels were significantly increased; the glutathione peroxidase levels were significantly decreased in LC group. The serum levels of TOS and paraoxonase were significantly higher at the end of surgery in LC group. In addition, arylesterase level in the 30th minute was increased compared to baseline. Serum paraoxonase level at the end of surgery was significantly increased when compared to AWH group. Conclusions. Our study showed negative effects of pneumoperitoneum in both lung and systemic levels despite lung-protective ventilation strategy.

  7. Use of a risk assessment method to improve the safety of negative pressure wound therapy.

    Science.gov (United States)

    Lelong, Anne-Sophie; Martelli, Nicolas; Bonan, Brigitte; Prognon, Patrice; Pineau, Judith

    2014-06-01

    To conduct a risk analysis of the negative pressure wound therapy (NPWT) care process and to improve the safety of NPWT, a working group of nurses, hospital pharmacists, physicians and hospital managers performed a risk analysis for the process of NPWT care. The failure modes, effects and criticality analysis (FMECA) method was used for this analysis. Failure modes and their consequences were defined and classified as a function of their criticality to identify priority actions for improvement. By contrast to classical FMECA, the criticality index (CI) of each consequence was calculated by multiplying occurrence, severity and detection scores. We identified 13 failure modes, leading to 20 different consequences. The CI of consequences was initially 712, falling to 357 after corrective measures were implemented. The major improvements proposed included the establishment of 6-monthly training cycles for nurses, physicians and surgeons and the introduction of computerised prescription for NPWT. The FMECA method also made it possible to prioritise actions as a function of the criticality ranking of consequences and was easily understood and used by the working group. This study is, to our knowledge, the first to use the FMECA method to improve the safety of NPWT. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  8. The use of negative pressure wound therapy in the treatment of infected wounds. Case studies

    Directory of Open Access Journals (Sweden)

    Daniel de Alcântara Jones

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results and benefits obtained from the topical use of negative pressure wound therapy (NPWT in patients with infected wounds. METHODS: This was a retrospective study of 20 patients (17 males and three females, mean age 42 years with infected wounds treated using NPWT. The infected wounds were caused by trauma. The treatment system used was VAC.(r (Vacuum Assisted Closure, KCI, San Antonio, United States applied to the wound in continuous mode from 100 to 125 mmHg. The parameters related to the wounds (location, number of VAC changes, the size of the defects in the soft parts, and the evolution of the state of the wound, length of hospital stay, length of intravenous antibiotic therapy, and complications related to the use of this therapy were evaluated. RESULTS: The mean length of the hospital stay, use of NPWT, and antibacterial therapy were 41 days, 22.5 days, and 20 days respectively. The use of the VAC led to a mean reduction of 29% in the wound area (95.65-68.1 cm2; p < 0.05. Only one patient did not show any improvement in the final appearance of the wound with complete eradication of the infection. No complication directly caused by NPWT was observed. CONCLUSION: NPWT stimulates infection-free scar tissue formation in a short time, and is a quick and comfortable alternative to conventional infected wounds treatment methods.

  9. Takotsubo cardiomyopathy precipitated by negative pressure pulmonary oedema following total thyroidectomy

    Directory of Open Access Journals (Sweden)

    K S Bharathi

    2016-01-01

    Full Text Available 'Takotsubo cardiomyopathy (TCM' or 'stress cardiomyopathy' is a reversible cardiomyopathy that is precipitated by intense emotional or physical stress. This syndrome is characterised by symptoms mimicking acute coronary syndrome with transient systolic dysfunction associated with regional wall motion abnormalities, which extend beyond a single coronary vascular bed in the absence of obstructive coronary vascular disease. The presentation of TCM and myocardial infarction is similar with sudden onset of chest pain, breathlessness as well as abnormalities in both the electrocardiogram and cardiac enzymes. It is difficult to differentiate between the two until cardiac catheterisation establishes the diagnosis. We report a case of TCM in a post-menopausal female, precipitated by negative pressure pulmonary oedema following total thyroidectomy in whom timely cardiac catheterisation established the diagnosis and influenced the management. Heightened awareness of this unique cardiomyopathy is essential to have a high index of suspicion in at-risk population for the prompt diagnosis of stress-related cardiomyopathy syndromes occurring in the perioperative period.

  10. Comparing negative pressure wound treatment with honey dressing in healing of foot ulcers in diabetics

    International Nuclear Information System (INIS)

    Bashir, U.; Maqsood, R.; Shabbir, H.

    2018-01-01

    To evaluate and compare the effectiveness of vacuum assisted treatment with that of honey dressing in duration of healing of foot ulcers in diabetics. Study Design: Randomized control study. Place and Duration of Study: Combined Military Hospital Multan and Nishtar Hospital Multan, from Aug 2016 till Feb 2017. Patients and Methods: A total of 95 patients with ages between 30-60 years of both sexes, who presented with diabetic ulcers of foot involving subcutaneous tissue and skin. Patients were divided randomly into two groups; Group V and H. Group V was subjected to Vacuum Pack closure (negative pressure wound treatment) and group H was treated with honey dressing, follow up was done till the appearance of healthy tissue after initial debridement, suitable for STSG (Split Thickness Skin Graft) or primary closure. Results: Healthy tissue appeared much faster in Vacuum assisted treatment, then with honey dressing with mean of 18.2 days for V.A.C and 28.8 days for honey dressing. Conclusion: Vacuum assisted closure was more effective in the treatment of foot ulcers in diabetics. It promotes healthy granulation tissue in the wound bed at a faster rate in comparison to honey dressing. (author)

  11. Effect of negative pressure wound therapy on molecular markers in diabetic foot ulcers.

    Science.gov (United States)

    Karam, Rehab A; Rezk, Noha A; Abdel Rahman, Tamer M; Al Saeed, Mohamed

    2018-08-15

    Diabetic foot ulcers are one of the most common complications of diabetes with high morbidity and mortality. Negative pressure wound therapy (NPWT) is one of the treatment modalities that facilitates the wound healing process; however, its molecular mechanism remains unclear. The aim of this study was to investigate the mechanism of action of NPWT in the treatment of diabetic foot ulcers via measuring the tissue expression of genes related to the wound healing process. The study included 40 patients with diabetic foot ulceration, 20 of them received NPWT and the other 20 were a control group treated with advanced moist therapy. Granulation tissue biopsies were obtained before and 10 days after treatment in both groups and subjected to real-time polymerase chain reaction to measure the mRNA expression of TGF-β1, VEGF, TNF-α, IL-1β, MMP-1, MMP-9 and TIMP-1 which are involved in the wound healing pathway. After 10 days of treatment with NPWT, the mRNA levels of IL-1β, TNF-α, MMP-1, and MMP-9 were significantly downregulated, while the levels of VEGF, TGF-β1 and TIMP-1 were significantly increased. Our study demonstrated that NPWT promotes wound healing in diabetic foot ulcers possibly by affecting growth factors, inflammatory cytokines, and matrix metalloproteinases. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Efficacy of Negative Pressure Wound Treatment in Preventing Surgical Site Infections after Whipple Procedures.

    Science.gov (United States)

    Gupta, Ryan; Darby, Geoffrey C; Imagawa, David K

    2017-10-01

    Surgical site infections (SSIs) occur at an average rate of 21.1 per cent after Whipple procedures per NSQIP data. In the setting of adherence to standard National Surgery Quality Improvement Program (NSQIP) Hepatopancreatobiliary recommendations including wound protector use and glove change before closing, this study seeks to evaluate the efficacy of using negative pressure wound treatment (NPWT) over closed incision sites after a Whipple procedure to prevent SSI formation. We retrospectively examined consecutive patients from January 2014 to July 2016 who met criteria of completing Whipple procedures with full primary incision closure performed by a single surgeon at a single institution. Sixty-one patients were included in the study between two cohorts: traditional dressing (TD) (n = 36) and NPWT dressing (n = 25). There was a statistically significant difference (P = 0.01) in SSI formation between the TD cohort (n = 15, SSI rate = 0.41) and the NPWT cohort (n = 3, SSI rate = 0.12). The adjusted odds ratio (OR) of SSI formation was significant for NPWT use [OR = 0.15, P = 0.036] and for hospital length of stay [OR = 1.21, P = 0.024]. Operative length, operative blood loss, units of perioperative blood transfusion, intraoperative gastrojejunal tube placement, preoperative stent placement, and postoperative antibiotic duration did not significantly impact SSI formation (P > 0.05).

  13. Raman spectroscopic measurements of CO2 density: Experimental calibration with high-pressure optical cell (HPOC) and fused silica capillary capsule (FSCC) with application to fluid inclusion observations

    Science.gov (United States)

    Wang, X.; Chou, I-Ming; Hu, W.; Burruss, Robert; Sun, Q.; Song, Y.

    2011-01-01

    Raman spectroscopy is a powerful method for the determination of CO2 densities in fluid inclusions, especially for those with small size and/or low fluid density. The relationship between CO2 Fermi diad split (Δ, cm−1) and CO2 density (ρ, g/cm3) has been documented by several previous studies. However, significant discrepancies exist among these studies mainly because of inconsistent calibration procedures and lack of measurements for CO2fluids having densities between 0.21 and 0.75 g/cm3, where liquid and vapor phases coexist near room temperature.In this study, a high-pressure optical cell and fused silica capillary capsules were used to prepare pure CO2 samples with densities between 0.0472 and 1.0060 g/cm3. The measured CO2 Fermi diad splits were calibrated with two well established Raman bands of benzonitrile at 1192.6 and 1598.9 cm−1. The relationship between the CO2 Fermi diad split and density can be represented by: ρ = 47513.64243 − 1374.824414 × Δ + 13.25586152 × Δ2 − 0.04258891551 × Δ3(r2 = 0.99835, σ = 0.0253 g/cm3), and this relationship was tested by synthetic fluid inclusions and natural CO2-rich fluid inclusions. The effects of temperature and the presence of H2O and CH4 on this relationship were also examined.

  14. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    Science.gov (United States)

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  15. Fluid Delivery System For Capillary Electrophoretic Applications.

    Science.gov (United States)

    Li, Qingbo; Liu, Changsheng; Kane, Thomas E.; Kernan, John R.; Sonnenschein, Bernard; Sharer, Michael V.

    2002-04-23

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  16. Microfluidic PMMA interfaces for rectangular glass capillaries

    International Nuclear Information System (INIS)

    Evander, Mikael; Tenje, Maria

    2014-01-01

    We present the design and fabrication of a polymeric capillary fluidic interface fabricated by micro-milling. The design enables the use of glass capillaries with any kind of cross-section in complex microfluidic setups. We demonstrate two different designs of the interface; a double-inlet interface for hydrodynamic focusing and a capillary interface with integrated pneumatic valves. Both capillary interfaces are presented together with examples of practical applications. This communication shows the design optimization and presents details of the fabrication process. The capillary interface opens up for the use of complex microfluidic systems in single-use glass capillaries. They also enable simple fabrication of glass/polymer hybrid devices that can be beneficial in many research fields where a pure polymer chip negatively affects the device's performance, e.g. acoustofluidics. (technical note)

  17. Oscillatory lower body negative pressure impairs working memory task-related functional hyperemia in healthy volunteers.

    Science.gov (United States)

    Merchant, Sana; Medow, Marvin S; Visintainer, Paul; Terilli, Courtney; Stewart, Julian M

    2017-04-01

    Neurovascular coupling (NVC) describes the link between an increase in task-related neural activity and increased cerebral blood flow denoted "functional hyperemia." We previously showed induced cerebral blood flow oscillations suppressed functional hyperemia; conversely functional hyperemia also suppressed cerebral blood flow oscillations. We used lower body negative pressure (OLBNP) oscillations to force oscillations in middle cerebral artery cerebral blood flow velocity (CBFv). Here, we used N-back testing, an intellectual memory challenge as a neural activation task, to test the hypothesis that OLBNP-induced oscillatory cerebral blood flow can reduce functional hyperemia and NVC produced by a working memory task and can interfere with working memory. We used OLBNP (-30 mmHg) at 0.03, 0.05, and 0.10 Hz and measured spectral power of CBFv at all frequencies. Neither OLBNP nor N-back, alone or combined, affected hemodynamic parameters. 2-Back power and OLBNP individually were compared with 2-back power during OLBNP. 2-Back alone produced a narrow band increase in oscillatory arterial pressure (OAP) and oscillatory cerebral blood flow power centered at 0.0083 Hz. Functional hyperemia in response to 2-back was reduced to near baseline and 2-back memory performance was decreased by 0.03-, 0.05-, and 0.10-Hz OLBNP. OLBNP alone produced increased oscillatory power at frequencies of oscillation not suppressed by added 2-back. However, 2-back preceding OLBNP suppressed OLBNP power. OLBNP-driven oscillatory CBFv blunts NVC and memory performance, while memory task reciprocally interfered with forced CBFv oscillations. This shows that induced cerebral blood flow oscillations suppress functional hyperemia and functional hyperemia suppresses cerebral blood flow oscillations. NEW & NOTEWORTHY We show that induced cerebral blood flow oscillations suppress functional hyperemia produced by a working memory task as well as memory task performance. We conclude that oscillatory

  18. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  19. Phase Behaviors of Reservoir Fluids with Capillary Eff ect Using Particle Swarm Optimization

    KAUST Repository

    Ma, Zhiwei

    2013-05-06

    The study of phase behavior is important for the oil and gas industry. Many approaches have been proposed and developed for phase behavior calculation. In this thesis, an alternative method is introduced to study the phase behavior by means of minimization of Helmholtz free energy. For a system at fixed volume, constant temperature and constant number of moles, the Helmholtz free energy reaches minimum at the equilibrium state. Based on this theory, a stochastic method called Particle Swarm Optimization (PSO) algorithm, is implemented to compute the phase diagrams for several pure component and mixture systems. After comparing with experimental and the classical PT-ash calculation, we found the phase diagrams obtained by minimization of the Helmholtz Free Energy approach match the experimental and theoretical diagrams very well. Capillary effect is also considered in this thesis because it has a significant influence on the phase behavior of reservoir fluids. In this part, we focus on computing the phase envelopes, which consists of bubble and dew point lines. Both fixed and calculated capillary pressure from the Young-Laplace equation cases are introduced to study their effects on phase envelopes. We found that the existence of capillary pressure will change the phase envelopes. Positive capillary pressure reduces the dew point and bubble point temperatures under the same pressure condition, while the negative capillary pressure increases the dew point and bubble point temperatures. In addition, the change of contact angle and pore radius will affect the phase envelope. The effect of the pore radius on the phase envelope is insignificant when the radius is very large. These results may become reference for future research and study. Keywords: Phase Behavior; Particle Swarm Optimization; Capillary Pressure; Reservoir Fluids; Phase Equilibrium; Phase Envelope.

  20. Phase Behaviors of Reservoir Fluids with Capillary Eff ect Using Particle Swarm Optimization

    KAUST Repository

    Ma, Zhiwei

    2013-01-01

    The study of phase behavior is important for the oil and gas industry. Many approaches have been proposed and developed for phase behavior calculation. In this thesis, an alternative method is introduced to study the phase behavior by means of minimization of Helmholtz free energy. For a system at fixed volume, constant temperature and constant number of moles, the Helmholtz free energy reaches minimum at the equilibrium state. Based on this theory, a stochastic method called Particle Swarm Optimization (PSO) algorithm, is implemented to compute the phase diagrams for several pure component and mixture systems. After comparing with experimental and the classical PT-ash calculation, we found the phase diagrams obtained by minimization of the Helmholtz Free Energy approach match the experimental and theoretical diagrams very well. Capillary effect is also considered in this thesis because it has a significant influence on the phase behavior of reservoir fluids. In this part, we focus on computing the phase envelopes, which consists of bubble and dew point lines. Both fixed and calculated capillary pressure from the Young-Laplace equation cases are introduced to study their effects on phase envelopes. We found that the existence of capillary pressure will change the phase envelopes. Positive capillary pressure reduces the dew point and bubble point temperatures under the same pressure condition, while the negative capillary pressure increases the dew point and bubble point temperatures. In addition, the change of contact angle and pore radius will affect the phase envelope. The effect of the pore radius on the phase envelope is insignificant when the radius is very large. These results may become reference for future research and study. Keywords: Phase Behavior; Particle Swarm Optimization; Capillary Pressure; Reservoir Fluids; Phase Equilibrium; Phase Envelope.

  1. Clinical Features of Patients with Diffuse Alveolar Hemorrhage due to Negative-Pressure Pulmonary Edema.

    Science.gov (United States)

    Contou, Damien; Voiriot, Guillaume; Djibré, Michel; Labbé, Vincent; Fartoukh, Muriel; Parrot, Antoine

    2017-08-01

    Diffuse alveolar hemorrhage (DAH) with negative-pressure pulmonary edema (NPPE) is an uncommon yet life-threatening condition. We aimed at describing the circumstances, clinical, radiological, and bronchoscopic features, as well as the outcome of patients with NPPE-related DAH. We performed a retrospective, observational cohort study, using data prospectively collected over 35 years in an intensive care unit (ICU). Of the 149 patients admitted for DAH, we identified 18 NPPE episodes in 15 patients, one admitted four times for recurrent NPPE-related DAH. The patients were primarily young, male, and athletic. The NPPE setting was postoperative (n = 12/18, 67%) or following generalized tonic-clonic seizures (n = 6/18, 33%). Hemoptysis was almost constant (n = 17/18, 94%), yet rarely massive (>200 cc, n = 1/18, 6%), with anemia observed in 10 (56%) episodes. The DAH triad (hemoptysis, anemia, and pulmonary infiltrates) was observed in 50% of episodes (n = 9/18), and acute respiratory failure in 94% (n = 17/18). Chest computed tomography revealed diffuse bilateral ground glass opacities (n = 10/10, 100%), while bronchoscopy detected bilateral hemorrhage (n = 12/12, 100%) and macroscopically bloody bronchoalveolar lavage, with siderophage absence in most (n = 7/8, 88%), indicating acute DAH. While one episode proved fatal, the other 17 recovered rapidly, with a mean ICU stay lasting 4.6 (2-15) days. Typically, the evolution was rapidly favorable under supportive care. NPPE-related DAH is a rare life-threatening condition occurring primarily after tonic-clonic generalized seizure or generalized anesthesia. Clinical circumstances are a key to its diagnosis. Early diagnosis and recognition likely allow for successful management of this potentially serious complication, whereas ictal-DAH appears ominous in epileptic patients.

  2. Negative pressure wound therapy after partial diabetic foot amputation: a multicentre, randomised controlled trial.

    Science.gov (United States)

    Armstrong, David G; Lavery, Lawrence A

    2005-11-12

    Diabetic foot wounds, particularly those secondary to amputation, are very complex and difficult to treat. We investigated whether negative pressure wound therapy (NPWT) improves the proportion and rate of wound healing after partial foot amputation in patients with diabetes. We enrolled 162 patients into a 16-week, 18-centre, randomised clinical trial in the USA. Inclusion criteria consisted of partial foot amputation wounds up to the transmetatarsal level and evidence of adequate perfusion. Patients who were randomly assigned to NPWT (n=77) received treatment with dressing changes every 48 h. Control patients (n=85) received standard moist wound care according to consensus guidelines. NPWT was delivered through the Vacuum Assisted Closure (VAC) Therapy System. Wounds were treated until healing or completion of the 112-day period of active treatment. Analysis was by intention to treat. This study has been registered with , number NCT00224796. More patients healed in the NPWT group than in the control group (43 [56%] vs 33 [39%], p=0.040). The rate of wound healing, based on the time to complete closure, was faster in the NPWT group than in controls (p=0.005). The rate of granulation tissue formation, based on the time to 76-100% formation in the wound bed, was faster in the NPWT group than in controls (p=0.002). The frequency and severity of adverse events (of which the most common was wound infection) were similar in both treatment groups. NPWT delivered by the VAC Therapy System seems to be a safe and effective treatment for complex diabetic foot wounds, and could lead to a higher proportion of healed wounds, faster healing rates, and potentially fewer re-amputations than standard care.

  3. A prospective randomized evaluation of negative-pressure wound dressings for diabetic foot wounds.

    Science.gov (United States)

    Eginton, Mark T; Brown, Kellie R; Seabrook, Gary R; Towne, Jonathan B; Cambria, Robert A

    2003-11-01

    Optimal treatment for large diabetic foot wounds is ill defined. The purpose of this study was to compare the rate of wound healing with the Vacuum Assisted Closure device trade mark (VAC) to conventional moist dressings in the treatment of large diabetic foot wounds. Diabetics with significant soft tissue defects of the foot were considered for enrollment. Patients were randomized to receive either moist gauze dressings or VAC treatments for 2 weeks, after which they were treated with the alternative dressing for an additional 2 weeks. Wounds were photographed weekly and wound dimensions calculated in a blinded fashion with spatial analysis software. Percent change in wound dimensions were calculated and compared for each weekly assessment and over 2 weeks of therapy with each dressing type. Ten patients were enrolled in the trial, but two were lost to follow-up and two were withdrawn. Complete data were available for analysis on seven wounds in six patients. Average length, width, and depth of the wounds at initiation of the trial was 7.7, 3.5, and 3.1 cm, respectively. Only the wound depth was significantly decreased over the weeks of the trial to 1.2 cm ( p VAC dressings decreased the wound volume and depth significantly more than moist gauze dressings (59% vs. 0% and 49% vs. 8%, respectively). VAC dressings were associated with a decrease in all wound dimensions while wound length and width increased with moist dressings. In summary, over the first several weeks of therapy, VAC dressings decreased wound depth and volume more effectively than moist gauze dressings. Negative-pressure wound treatment may accelerate closure of large foot wounds in the diabetic patient.

  4. Cost-Utility Analysis: Sartorius Flap versus Negative Pressure Therapy for Infected Vascular Groin Graft Managment.

    Science.gov (United States)

    Chatterjee, Abhishek; Macarios, David; Griffin, Leah; Kosowski, Tomasz; Pyfer, Bryan J; Offodile, Anaeze C; Driscoll, Daniel; Maddali, Sirish; Attwood, John

    2015-11-01

    Sartorius flap coverage and adjunctive negative pressure wound therapy (NPWT) have been described in managing infected vascular groin grafts with varying cost and clinical success. We performed a cost-utility analysis comparing sartorius flap with NPWT in managing an infected vascular groin graft. A literature review compiling outcomes for sartorius flap and NPWT interventions was conducted from peer-reviewed journals in MEDLINE (PubMed) and EMBASE. Utility scores were derived from expert opinion and used to estimate quality-adjusted life years (QALYs). Medicare current procedure terminology and diagnosis-related groups codes were used to assess the costs for successful graft salvage with the associated complications. Incremental cost-effectiveness was assessed at $50,000/QALY, and both univariate and probabilistic sensitivity analyses were conducted to assess robustness of the conclusions. Thirty-two studies were used pooling 384 patients (234 sartorius flaps and 150 NPWT). NPWT had better clinical outcomes (86.7% success rate, 0.9% minor complication rate, and 13.3% major complication rate) than sartorius flap (81.6% success rate, 8.0% minor complication rate, and 18.4% major complication rate). NPWT was less costly ($12,366 versus $23,516) and slightly more effective (12.06 QALY versus 12.05 QALY) compared with sartorius flap. Sensitivity analyses confirmed the robustness of the base case findings; NPWT was either cost-effective at $50,000/QALY or dominated sartorius flap in 81.6% of all probabilistic sensitivity analyses. In our cost-utility analysis, use of adjunctive NPWT, along with debridement and antibiotic treatment, for managing infected vascular groin graft wounds was found to be a more cost-effective option when compared with sartorius flaps.

  5. Cost-effectiveness analysis alongside a pilot study of prophylactic negative pressure wound therapy.

    Science.gov (United States)

    Heard, Christopher; Chaboyer, Wendy; Anderson, Vinah; Gillespie, Brigid M; Whitty, Jennifer A

    2017-02-01

    Negative pressure wound therapy (NPWT) is increasingly used prophylactically following surgery despite limited evidence of clinical or cost-effectiveness. To evaluate whether NPWT is cost-effective compared to standard care, for the prevention of surgical site infection (SSI) in obese women undergoing elective caesarean section, and inform development of a larger trial. An economic evaluation was conducted alongside a pilot randomised controlled trial at one Australian hospital, in which women were randomised to NPWT (n = 44) or standard care (n = 43). A public health care provider perspective and time horizon to four weeks post-discharge was adopted. Cost-effectiveness assessment was based on incremental cost per SSI prevented and per quality-adjusted life year (QALY) gained. Patients receiving NPWT each received health care costing AU$5887 (±1038) and reported 0.069 (±0.010) QALYs compared to AU$5754 (±1484) and 0.066 (±0.010) QALYs for patients receiving standard care. NPWT may be slightly more costly and more effective than standard care, with estimated incremental cost-effectiveness ratios (ICERs) of AU$1347 (95%CI dominant- $41,873) per SSI prevented and AU$42,340 (95%CI dominant- $884,019) per QALY gained. However, there was considerable uncertainty around these estimates. NPWT may be cost-effective in the prophylactic treatment of surgical wounds following elective caesarean section in obese women. Larger trials could clarify the cost-effectiveness of NPWT as a prophylactic treatment for SSI. Sensitive capture of QALYs and cost offsets will be important given the high level of uncertainty around the point estimate cost-effectiveness ratio which was close to conventional thresholds. ACTRN12612000171819. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  6. Negative pressure wound therapy for Gustilo Anderson grade IIIb open tibial fractures.

    Science.gov (United States)

    Park, Chul Hyun; Shon, Oog Jin; Kim, Gi Beom

    2016-09-01

    Traditionally, Gustilo Anderson grade IIIb open tibial fractures have been treated by initial wide wound debridement, stabilization of fracture with external fixation, and delayed wound closure. The purpose of this study is to evaluate the clinical and radiological results of staged treatment using negative pressure wound therapy (NPWT) for Gustilo Anderson grade IIIb open tibial fractures. 15 patients with Gustilo Anderson grade IIIb open tibial fractures, treated using staged protocol by a single surgeon between January 2007 and December 2011 were reviewed in this retrospective study. The clinical results were assessed using a Puno scoring system for severe open fractures of the tibia at the last followup. The range of motion (ROM) of the knee and ankle joints and postoperative complication were evaluated at the last followup. The radiographic results were assessed using time to bone union, coronal and sagittal angulations and a shortening at the last followup. The mean score of Puno scoring system was 87.4 (range 67-94). The mean ROM of the knee and ankle joints was 121.3° (range 90°-130°) and 37.7° (range 15°-50°), respectively. Bone union developed in all patients and the mean time to union was 25.3 weeks (range 16-42 weeks). The mean coronal angulation was 2.1° (range 0-4°) and sagittal was 2.7° (range 1-4°). The mean shortening was 4.1 mm (range 0-8 mm). Three patients had partial flap necrosis and 1 patient had total flap necrosis. There was no superficial and deep wound infection. Staged treatment using NPWT decreased the risks of infection and requirement of flap surgeries in Gustilo Anderson grade IIIb open tibial fractures. Therefore, staged treatment using NPWT could be a useful treatment option for Gustilo Anderson grade IIIb open tibial fractures.

  7. Suture Technique to Prevent Air Leakage during Negative-Pressure Wound Therapy in Fournier Gangrene.

    Science.gov (United States)

    Chang, Feng-Shu; Chou, Chieh; Hu, Chuan-Yu; Huang, Shu-Hung

    2018-01-01

    The use of negative-pressure wound therapy (NPWT) for Fournier gangrene management is well documented; however, it is difficult to fixate GranuFoam dressings and maintain an airtight seal over the perineum area. We developed a simple method to facilitate GranuFoam fixation and improve airtight sealing. The Fournier's gangrene severity index (FGSI) score less than 9 was collected in from January 2015 to October 2016. All 13 patients underwent fasciotomy, and NPWT was applied directly on fasciotomy wounds after the debridement of infected tissue. Partial wound closure was performed, and a portion of GranuFoam was inserted to facilitate fixation. The seal check was converted to a 0-10 scale score that was recorded every 4 hours during NPWT. Patient profiles including medical history, FGSI, method of wound closure, and length of stay were collected in this study. The median age of the patients was 62 (38-76) years. The mean FGSI score was 4.3 ± 3.1. The average duration of NPWT was 17.5 ± 11.5 days, and the average seal check score was 0.8 ± 0.5. No seal check alarms were noted during the study. Successful wound closure was achieved in all patients without using additional reconstruction methods such as skin grafting or muscle flap coverage. The present results suggest that partial wound-edge closure and in situ GranuFoam fixation improve the NPWT leaks in Fournier gangrene wounds. Furthermore, this method is simple to learn and can be useful in applying NPWT to anatomically difficult areas.

  8. Evaluation of a Decision-Making Curriculum for Teaching Adolescents with Disabilities to Resist Negative Peer Pressure

    Science.gov (United States)

    Khemka, Ishita; Hickson, Linda; Mallory, Sarah B.

    2016-01-01

    This study was designed to assess the impact of a decision-making curriculum (PEER-DM) on the social peer relationship knowledge and self-protective decision-making skills of adolescents with disabilities in hypothetical situations involving negative peer pressure. A randomized design was used to assign students with disabilities from…

  9. Major bleeding during negative pressure wound/VAC (R) - therapy for postsurgical deep sternal wound infection - a critical appraisal

    NARCIS (Netherlands)

    van Wingerden, J.J.; Segers, P.; Jekel, L.

    2011-01-01

    Negative-pressure wound therapy, commercially known as vacuum-assisted closure (V.A.C.(R)) therapy, has become one of the most popular (and efficacious) interim (prior to flap reconstruction) or definite methods of managing deep sternal wound infection. Complications such as profuse bleeding, which

  10. A comparative study of the efficacy of topical negative pressure moist dressings and conventional moist dressings in chronic wounds

    Directory of Open Access Journals (Sweden)

    Tauro Leo

    2007-01-01

    Full Text Available Aim: To assess the efficacy of topical negative pressure moist wound dressing as compared to conventional moist wound dressings in improving the healing process in chronic wounds and to prove that negative pressure dressings can be used as a much better treatment option in the management of chronic wounds. Materials and Methods: This is a prospective comparative study of data from 112 patients with chronic wounds, of which 56 patients underwent topical negative pressure dressings (17 diabetic, 10 pressure sores, nine ischemic, two varicose, 10 post-infective raw areas and eight traumatic - six had bone exposed, two orthopaedic prosthesis exposed. The remaining 56 patients underwent conventional moist dressings (20 diabetic, two ischemic, 15 pressure sores, three varicose, eight post-infective raw areas and eight traumatic - five had bone exposed, three orthopaedic prosthesis exposed. The results were compared after 10 days. The variables compared were, rate of granulation tissue formation as a percentage of ulcer area covered, skin graft take up as the percentage of ulcer surface area and duration of hospital stay. The variables were compared using Unpaired Student′s t test. A " P" value < 0.05 was considered significant. Results: Out of 56 patients who underwent topical negative pressure dressings, six (10.71% were failures, due to failure in maintaining topical negative pressure due to defective sealing technique; these were included into the study group. After 10 days, the mean rate of granulation tissue formation was 71.43% of ulcer surface area. All these 56 cases underwent split-thickness skin grafting. The mean graft take-up was 79.29%. The mean hospital stay was 32.64 days. In the remaining 56 patients, the mean rate of granulation tissue formation was 52.85% of ulcer surface area. The mean graft take-up was only 60.45% of the total ulcer surface area. The mean hospital stay was 60.45 days. Conclusion: To conclude, topical negative

  11. Cervical spine disease may result in a negative lumbar spinal drainage trial in normal pressure hydrocephalus: case report.

    Science.gov (United States)

    Komotar, Ricardo J; Zacharia, Brad E; Mocco, J; Kaiser, Michael G; Frucht, Stephen J; McKhann, Guy M

    2008-10-01

    In this case report, we present a patient with normal pressure hydrocephalus in whom a lumbar drainage trial yielded a false-negative result secondary to cervical spondylosis. An 80-year-old woman presented with classic symptoms of normal pressure hydrocephalus as well as evidence of cervical myelopathy. Magnetic resonance imaging of the brain and spine showed enlarged ventricles and single-level cervical canal narrowing. An initial lumbar drainage trial was performed, which revealed negative results. The patient then underwent cervical decompression and fusion. Despite this procedure, the patient's symptoms continued to worsen. A repeat lumbar drainage trial was performed with positive results. Subsequently, a ventriculoperitoneal shunt was placed, resulting in significant improvement of her symptoms. This case report illustrates how altered cerebrospinal fluid flow dynamics may impact the accuracy of the lumbar spinal drainage trial in patients with normal pressure hydrocephalus.

  12. Negative pressure wound therapy in complex cranio-maxillofacial and cervical wounds.

    Science.gov (United States)

    Novelli, Giorgio; Daleffe, Francesco; Birra, Gisella; Canzi, Gabriele; Mazzoleni, Fabio; Boni, Pietro; Maino, Clara; Giussani, Carlo; Sozzi, Davide; Bozzetti, Alberto

    2018-02-01

    The care and the management of the healing of difficult wounds at the level of the skull-facial face many problems related to patient compliance and the need to perform multiple dressings, with long periods of healing and, occasionally, a very long hospitalisation period. The introduction and evolution of negative pressure wound therapy (NPWT) in the treatment of difficult wounds has resulted in better healing, with a drastic reduction in terms of time and biological costs to the patient and cost to the health care system. The main aim of this study is to describe and discuss, using out our experience, the usefulness of NPWT in the cranial-facial-cervical region. We studied 16 patients with complex wounds of the cranial-facial-cervical region treated with NPWT. We divided clinical cases in four groups: cervicofacial infectious disease, healing complications in oncological-reconstructive surgery, healing complications of injury with exposure of bone and/or internal fixations and healing complications in traumatic injury with loss of substance. We evaluated complete or incomplete wound healing; application time, related also to hospitalisation time; days of intensive care unit (ICU) stay; management of the upper airways; timing of medication renewal; and patient comfort and compliance (on a scale of 1-5). Depression values were always between -75 and -125 mmHg in a continuous aspiration pattern. For every patient, we used the ActiVAC Therapy Unit, derived from the vacuum-assisted closure system (Kinetic Concepts Inc., San Antonio, TX). Medication renewals were performed every 48-72 hours. The NPWT application time ranged from 4 to 22 days (mean of 11·57 day). Therapy was effective to gain a complete restitutio ad integrum in every patient included in the group of cervicofacial infectious disease. Therapy has, however, been well tolerated in our series; this is probably due to the decreased number of applications, the ease of use and the comfort of the system

  13. Cost analysis of Topical Negative Pressure (TNP Therapy for traumatic acquired wounds

    Directory of Open Access Journals (Sweden)

    Freytag, Sebastian

    2010-01-01

    Full Text Available Extended traumatic wounds require extended reconstructive operations and are accompanied by long hospitalizations and risks of infection, thrombosis and flap loss. In particular, the frequently used Topical Negative Pressure (TNP Therapy is regarded as cost-intensive. The costs of TNP in the context of traumatic wounds is analyzed using the method of health economic evaluation.All patients (n=67: 45 male, 22 female; average age 54 y with traumatically acquired wounds being treated with TNP at the university hospital of Goettingen in the period 01/01/2005–31/12/2007 comprise the basis for this analysis. The concept of activity-based costing based on clinical pathways according to InEK (National Institute for the Hospital Remuneration System systematic calculations was chosen for cost accounting. In addition, a special module system adaptable for individual courses of disease was developed. The treated wounds were located on a lower extremity in 83.7% of cases (n=56 and on an upper extremity in 16.3% of cases (n=11. The average time of hospitalization of the patients was 54 days. Twenty-five patients (37.31% exceeded the „maximum length of stay“ of their associated DRG (Diagnosis Related Groups. The total PCCL (patient clinical complexity level = patient severity score of 2.99 reflects the seriousness of disease. For the treatment of the 67 patients, total costs were $1,729,922.32 (1,249,176.91 €. The cost calculation showed a financial deficit of $–210,932.50 (–152,314.36 €. Within the entire treatment costs of $218,848.07 (158,030.19 €, 12.65% per case were created by TNP with material costs of $102,528.74 (74,036 €, representing 5.92% of entire costs. The cost of TNP per patient averaged $3,266.39 (2,358.66 €. The main portion of the costs was not – as is often expected – due to high material costs of TNP but instead to long-term treatments. Because of their complexity, the cases are insufficiently represented in the

  14. Short communication: Identification of coagulase-negative staphylococcus species from goat milk with the API Staph identification test and with transfer RNA-intergenic spacer PCR combined with capillary electrophoresis.

    Science.gov (United States)

    Koop, G; De Visscher, A; Collar, C A; Bacon, D A C; Maga, E A; Murray, J D; Supré, K; De Vliegher, S; Haesebrouck, F; Rowe, J D; Nielen, M; van Werven, T

    2012-12-01

    Coagulase-negative staphylococci (CNS) are the most commonly isolated bacteria from goat milk, but they have often been identified with phenotypic methods, which may have resulted in misclassification. The aims of this paper were to assess the amount of misclassification of a phenotypic test for identifying CNS species from goat milk compared with transfer RNA intergenic spacer PCR (tDNA-PCR) followed by capillary electrophoresis, and to apply the tDNA-PCR technique on different capillary electrophoresis equipment. Milk samples were collected from 416 does in 5 Californian dairy goat herds on 3 occasions during lactation. In total, 219 CNS isolates were identified at the species level with tDNA-PCR and subjected to the API 20 Staph identification test kit (API Staph; bioMérieux, Durham, NC). If the same species was isolated multiple times from the same udder gland, only the first isolate was used for further analyses, resulting in 115 unique CNS isolates. According to the tDNA-PCR test, the most prevalent CNS species were Staphylococcus epidermidis, Staphylococcus caprae, and Staphylococcus simulans. Typeability with API staph was low (72%). Although the API Staph test was capable of identifying the majority of Staph. epidermidis and Staph. caprae isolates, sensitivity for identification of Staph. simulans was low. The true positive fraction was high for the 3 most prevalent species. It was concluded that the overall performance of API Staph in differentiating CNS species from goat milk was moderate to low, mainly because of the low typeability, and that genotypic methods such as tDNA-PCR are preferred. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Insomnia complaints in lean patients with obstructive sleep apnea negatively affect positive airway pressure treatment adherence.

    Science.gov (United States)

    Eysteinsdottir, Bjorg; Gislason, Thorarinn; Pack, Allan I; Benediktsdottir, Bryndís; Arnardottir, Erna S; Kuna, Samuel T; Björnsdottir, Erla

    2017-04-01

    The objective of this study was to evaluate the determinants of long-term adherence to positive airway pressure treatment among patients with obstructive sleep apnea, with special emphasis on patients who stop positive airway pressure treatment within 1 year. This is a prospective long-term follow-up of subjects in the Icelandic Sleep Apnea Cohort who were diagnosed with obstructive sleep apnea between 2005 and 2009, and started on positive airway pressure treatment. In October 2014, positive airway pressure adherence was obtained by systematically evaluating available clinical files (n = 796; 644 males, 152 females) with moderate to severe obstructive sleep apnea (apnea-hypopnea index ≥15 events per h). The mean follow-up time was 6.7 ± 1.2 years. In total, 123 subjects (15.5%) returned their positive airway pressure device within the first year, 170 (21.4%) returned it later and 503 (63.2%) were still using positive airway pressure. The quitters within the first year had lower body mass index, milder obstructive sleep apnea, less sleepiness, and more often had symptoms of initial and late insomnia compared with long-term positive airway pressure users at baseline. Both initial and late insomnia were after adjustment still significantly associated with being an early quitter among subjects with body mass index insomnia are associated with early quitting on positive airway pressure among non-obese subjects. © 2016 European Sleep Research Society.

  16. Changes in subcutaneous blood flow during locally applied negative pressure to the skin

    DEFF Research Database (Denmark)

    Skagen, K; Henriksen, O

    1983-01-01

    The effect of locally applied subatmospheric pressure on subcutaneous blood flow was studied in 12 healthy subjects. Blood flow was measured on the forearm by the local 133Xe wash-out technique. Air suction between 10 mmHg and 250 mmHg was applied to the skin. Subatmospheric pressure of 20 mm...

  17. [Efficacy observation on application of negative pressure therapy in the treatment of superficial partial-thickness scald wound in children].

    Science.gov (United States)

    Shen, Chuan-an; Chai, Jia-ke; Tuo, Xiao-ye; Cai, Jian-hua; Li, Dong-jie; Zhang, Lin; Zhu, Hua; Cai, Jin-dong

    2013-02-01

    To observe the effect of negative pressure therapy in the treatment of superficial partial-thickness scald in children. Three hundred and seven children with superficial partial-thickness scald hospitalized from August 2009 to May 2012 were divided into negative pressure therapy group (NPT, n = 145) and control group (C, n = 162) according to the random number table. Patients in group NPT were treated with negative pressure from within post injury day (PID) 3 to PID 9 (with -16 kPa pressure), while traditional occlusive dressing method was used in group C. Changes in body temperature, wound healing condition, frequency of dressing change were compared between group NPT and group C. Bacterial culture results of wounds were compared before and after treatment in group NPT. Volume of drained transudate per one percent of wound area was recorded in group NPT on PID 1 to PID 3. Data were processed with t test or chi-square test. The incidence of high fever was significantly lower in group NPT (26.9%, 39/145) than in group C (63.6%, 103/162, χ(2) = 41.419, P partial-thickness scald.

  18. Negative-pressure in treatment of persistent post-traumatic subcutaneous emphysema with respiratory failure: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Jakov Mihanović

    2018-02-01

    Full Text Available Subcutaneous emphysema may aggravate traumatic pneumothorax treatment, especially when mechanical ventilation is required. Expectative management usually suffices, but when respiratory function is impaired surgical treatment might be indicated. Historically relevant methods are blowhole incisions and placement of various drains, often with related wound complications. Since the first report of negative pressure wound therapy for the treatment of severe subcutaneous emphysema in 2009, only few publications on use of commercially available sets were published. We report on patient injured in a motor vehicle accident who had serial rib fractures and bilateral pneumothorax managed initially in another hospital. Due to respiratory deterioration, haemodynamic instability and renal failure patient was transferred to our Intensive Care Unit. Massive and persistent subcutaneous emphysema despite adequate thoracic drainage with respiratory deterioration and potentially injurious mechanical ventilation with high airway pressures was the indication for active surgical treatment. Negative-pressure wound therapy dressing was applied on typical blowhole incisions which resulted in swift emphysema regression and respiratory improvement. Negative pressure wound therapy for decompression of severe subcutaneous emphysema represents simple, effective and relatively unknown technique that deserves wider attention.

  19. Uniqueness of specific interfacial area-capillary pressure-saturation relationship under non-equilibrium conditions in two-phase porous media flow

    NARCIS (Netherlands)

    Joekar-Niasar, V.; Hassanizadeh, S.M.

    2012-01-01

    The capillary pressure–saturation (P c–S w) relationship is one of the central constitutive relationships used in two-phase flow simulations. There are two major concerns regarding this relation. These concerns are partially studied in a hypothetical porous medium using a dynamic pore-network model

  20. Use of dynamic CT in acute respiratory distress syndrome (ARDS) with comparison of positive and negative pressure ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Helm, Emma; Babyn, Paul [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Talakoub, Omid; Alirezaie, Javad [Ryerson University, Department of Electrical and Computer Engineering, Toronto, ON (Canada); Grasso, Francesco; Engelberts, Doreen; Kavanagh, Brian P. [Hospital for Sick Children and the University of Toronto, Departments of Anesthesia and Critical Care Medicine and the Program in Pulmonary and Experimental Medicine, Toronto (Canada)

    2009-01-15

    Negative pressure ventilation via an external device ('iron lung') has the potential to provide better oxygenation with reduced barotrauma in patients with ARDS. This study was designed to see if oxygenation differences between positive and negative ventilation could be explained by CT. Six anaesthetized rabbits had ARDS induced by repeated saline lavage. Rabbits were ventilated with positive pressure ventilation (PPV) and negative pressure ventilation (NPV) in turn. Dynamic CT images were acquired over the respiratory cycle. A computer-aided method was used to segment the lung and calculate the range of CT densities within each slice. Volumes of ventilated lung and atelectatic lung were measured over the respiratory cycle. NPV was associated with an increased percentage of ventilated lung and decreased percentage of atelectatic lung. The most significant differences in ventilation and atelectasis were seen at mid-inspiration and mid-expiration (ventilated lung NPV=61%, ventilated lung PPV=47%, p<0.001; atelectatic lung NPV=10%, atelectatic lung PPV 19%, p<0.001). Aeration differences were not significant at end-inspiration. Dynamic CT can show differences in lung aeration between positive and negative ventilation in ARDS. These differences would not be appreciated if only static breath-hold CT was used. (orig.)

  1. Does treatment of split-thickness skin grafts with negative-pressure wound therapy improve tissue markers of wound healing in a porcine experimental model?

    Science.gov (United States)

    Ward, Christopher; Ciraulo, David; Coulter, Michael; Desjardins, Steven; Liaw, Lucy; Peterson, Sarah

    2012-08-01

    Negative-pressure wound therapy (NPWT) has been used for to treat wounds for more than 15 years and, more recently, has been used to secure split-thickness skin grafts. There are some data to support this use of NPWT, but the actual mechanism by which NPWT speeds healing or improves skin graft take is not entirely known. The purpose of this project was to assess whether NPWT improved angiogenesis, wound healing, or graft survival when compared with traditional bolster dressings securing split-thickness skin grafts in a porcine model. We performed two split-thickness skin grafts on each of eight 30 kg Yorkshire pigs. We took graft biopsies on postoperative days 2, 4, 6, 8, and 10 and submitted the samples for immunohistochemical staining, as well as standard hematoxylin and eosin staining. We measured the degree of vascular ingrowth via immunohistochemical staining for von Willenbrand's factor to better identify blood vessel epithelium. We determined the mean cross-sectional area of blood vessels present for each representative specimen, and then compared the bolster and NPWT samples. We also assessed each graft for incorporation and survival at postoperative day 10. Our analysis of the data revealed that there was no statistically significant difference in the degree of vascular ingrowth as measured by mean cross-sectional capillary area (p = 0.23). We did not note any difference in graft survival or apparent incorporation on a macroscopic level, although standard hematoxylin and eosin staining indicated that microscopically, there seemed to be better subjective graft incorporation in the NPWT samples and a nonsignificant trend toward improved graft survival in the NPWT group. We were unable to demonstrate a significant difference in vessel ingrowth when comparing NPWT and traditional bolster methods for split-thickness skin graft fixation. More studies are needed to elucidate the manner by which NPWT exerts its effects and the true clinical magnitude of these

  2. Measurement of Capillary Radius and Contact Angle within Porous Media.

    Science.gov (United States)

    Ravi, Saitej; Dharmarajan, Ramanathan; Moghaddam, Saeed

    2015-12-01

    The pore radius (i.e., capillary radius) and contact angle determine the capillary pressure generated in a porous medium. The most common method to determine these two parameters is through measurement of the capillary pressure generated by a reference liquid (i.e., a liquid with near-zero contact angle) and a test liquid. The rate of rise technique, commonly used to determine the capillary pressure, results in significant uncertainties. In this study, we utilize a recently developed technique for independently measuring the capillary pressure and permeability to determine the equivalent minimum capillary radii and contact angle of water within micropillar wick structures. In this method, the experimentally measured dryout threshold of a wick structure at different wicking lengths is fit to Darcy's law to extract the maximum capillary pressure generated by the test liquid. The equivalent minimum capillary radii of different wick geometries are determined by measuring the maximum capillary pressures generated using n-hexane as the working fluid. It is found that the equivalent minimum capillary radius is dependent on the diameter of pillars and the spacing between pillars. The equivalent capillary radii of micropillar wicks determined using the new method are found to be up to 7 times greater than the current geometry-based first-order estimates. The contact angle subtended by water at the walls of the micropillars is determined by measuring the capillary pressure generated by water within the arrays and the measured capillary radii for the different geometries. This mean contact angle of water is determined to be 54.7°.

  3. Effects of topical negative pressure therapy on tissue oxygenation and wound healing in vascular foot wounds.

    Science.gov (United States)

    Chiang, Nathaniel; Rodda, Odette A; Sleigh, Jamie; Vasudevan, Thodur

    2017-08-01

    Topical negative pressure (TNP) therapy is widely used in the treatment of acute wounds in vascular patients on the basis of proposed multifactorial benefits. However, numerous recent systematic reviews have concluded that there is inadequate evidence to support its benefits at a scientific level. This study evaluated the changes in wound volume, surface area, depth, collagen deposition, and tissue oxygenation when using TNP therapy compared with traditional dressings in patients with acute high-risk foot wounds. This study was performed with hospitalized vascular patients. Forty-eight patients were selected with an acute lower extremity wound after surgical débridement or minor amputation that had an adequate blood supply without requiring further surgical revascularization and were deemed suitable for TNP therapy. The 22 patients who completed the study were randomly allocated to a treatment group receiving TNP or to a control group receiving regular topical dressings. Wound volume and wound oxygenation were analyzed using a modern stereophotographic wound measurement system and a hyperspectral transcutaneous oxygenation measurement system, respectively. Laboratory analysis was conducted on wound biopsy samples to determine hydroxyproline levels, a surrogate marker to collagen. Differences in clinical or demographic characteristics or in the location of the foot wounds were not significant between the two groups. All patients, with the exception of two, had diabetes. The two patients who did not have diabetes had end-stage renal failure. There was no significance in the primary outcome of wound volume reduction between TNP and control patients on day 14 (44.2% and 20.9%, respectively; P = .15). Analyses of secondary outcomes showed a significant result of better healing rates in the TNP group by demonstrating a reduction in maximum wound depth at day 14 (36.0% TNP vs 17.6% control; P = .03). No significant findings were found for the other outcomes of changes

  4. Viscosity measurement in the capillary tube viscometer under unsteady flow

    International Nuclear Information System (INIS)

    Park, Heung Jun; Yoo, Sang Sin; Suh, Sang Ho

    2000-01-01

    The objective of the present study is to develop a new device that the viscous characteristics of fluids are determined by applying the unsteady flow concept to the traditional capillary tube viscometer. The capillary tube viscometer consists of a small cylindrical reservoir, capillary tube, a load cell system that measures the mass flow rate, interfaces, and computer. Due to the small size of the reservoir the height of liquid in the reservoir decreases as soon as the liquid in the reservoir drains out through the capillary and the mass flow rate in the capillary decreases as the hydrostatic pressure in the reservoir decreases resulting in a decrease of the shear rate in the capillary tube. The instantaneous shear rate and driving force in the capillary tube are determined by measuring the mass flow rate through the capillary, and the fluid viscosity is determined from the measured flow rate and the driving force

  5. The penetration of aerosols through fine capillaries

    International Nuclear Information System (INIS)

    Mitchell, J.P.; Edwards, R.T.; Ball, M.H.E.

    1989-10-01

    A novel experimental technique has been developed to study the penetration of aerosol particles ranging from about 1 to 15 μm aerodynamic diameter through capillaries varying from 20 to 80 μm bore and from 10 to 50 mm in length. When the driving pressure was 100 kPa, the penetration of the airborne particles was considerably smaller than expected from a simple comparison of particle diameter with the bore of the capillary. Particle size distributions determined after penetration through the capillaries were in almost all cases similar to the particle size distribution of the aerosol at the capillary entrance. This lack of size-selectivity can be explained in terms of the capillary behaving as a conventional suction-based sampler from a near still (calm) air environment. The resulting particle penetration data are important in assessing the potential for the leakage of aerosols through seals in containers used to transport radioactive materials. (author)

  6. The efficacy of negative pressure wound therapy in treating sacroiliac joint tuberculosis with a chronic sinus tract: a case series.

    Science.gov (United States)

    Luo, Xiaobo; Tang, Xiangyu; Ma, Yuanzheng; Zhang, Yonggang; Fang, Shuzhi

    2015-08-06

    Tuberculous sacroiliitis with abscess accounts for approximately 50 % of all sacroiliac joint tuberculosis cases. Tuberculous abscesses spread into the sacroiliac joint capsule, subcutaneous tissue, and the skin, and finally becomes a skin sinus. As there are no previous reports about sacroiliac joint tuberculosis with a chronic sinus, we evaluated its clinical characteristics and management by negative pressure wound therapy. A retrospective analysis of 12 patients with sacroiliac joint tuberculosis with chronic sinuses treated between January 2005 and January 2010 was conducted. Patients were treated with negative pressure wound therapy (NPWT). Treatment was divided into three phases: control phase, standard dressing changes daily for 4 weeks; interphase washout period, dressing changes every 3 days for 1 week; and intervention phase, no dressing changes until minimal sinus tract drainage (sacroiliac joint tuberculosis with a chronic sinus can be difficult. NPWT provides better healing of sacroiliac joint tuberculosis with a chronic sinus than standard dressing changes.

  7. Papineau debridement, Ilizarov bone transport, and negative-pressure wound closure for septic bone defects of the tibia.

    Science.gov (United States)

    Karargyris, Orestis; Polyzois, Vasilios D; Karabinas, Panayiotis; Mavrogenis, Andreas F; Pneumaticos, Spyros G

    2014-08-01

    Ilizarov pioneered bone transport using a circular external fixator. Papineau described a staged technique for the treatment for infected pseudarthrosis of the long bones. This article presents a single-stage Papineau technique and Ilizarov bone transport, and postoperative negative-pressure wound dressing changes for septic bone defects of the tibia. We studied the files of seven patients (mean age, 32 years) with septic bone defects of the tibia treated with a Papineau technique and Ilizarov bone transport in a single stage, followed by postoperative negative-pressure wound dressing changes. All patients had septic pseudarthrosis and skin necrosis of the tibia. The technique included a single-stage extensive surgical debridement of necrotic bone, open bone grafting with cancellous bone autograft and bone transport, and postoperative negative-pressure wound dressing changes for wound closure. The mean time from the initial injury was 6 months (range, 4-8 months). The mean follow-up was 14 months (range, 10-17 months). All patients experienced successful wound healing at a mean of 29 days. Six patients experienced successful bone regeneration and union at the docking side at a mean of 6 months. One patient experienced delayed union at the docking site, which was treated with autologous cancellous bone grafting. Two patients experienced pin track infection, which was successfully treated with antibiotics and pin site dressing changes. All patients were able to return to their work and previous levels of activity, except one patient who had a stiff ankle joint and had to change his job. No patient experienced recurrence of infection, or fracture of the regenerated or transported bone segment until the period of this study. The combined Papineau and Ilizarov bone transport technique with negative-pressure wound closure provides for successful eradication of the infection, reconstruction of the bone defect, and soft-tissue closure. A single-stage surgical treatment is

  8. Comparison of Outcomes for Normal Saline and an Antiseptic Solution for Negative-Pressure Wound Therapy with Instillation.

    Science.gov (United States)

    Kim, Paul J; Attinger, Christopher E; Oliver, Noah; Garwood, Caitlin; Evans, Karen K; Steinberg, John S; Lavery, Larry A

    2015-11-01

    Negative-pressure wound therapy with instillation is an adjunctive treatment that uses periodic instillation of a solution and negative pressure for a wide diversity of wounds. A variety of solutions have been reported, with topical antiseptics as the most frequently chosen option. The objective of this study was to compare the outcomes of normal saline versus an antiseptic solution for negative-pressure wound therapy with instillation for the adjunctive treatment of infected wounds. This was a prospective, randomized, effectiveness study comparing 0.9% normal saline versus 0.1% polyhexanide plus 0.1% betaine for the adjunctive treatment of infected wounds that required hospital admission and operative débridement. One hundred twenty-three patients were eligible, with 100 patients randomized for the intention-to-treat analysis and 83 patients for the per-protocol analysis. The surrogate outcomes measured were number of operative visits, length of hospital stay, time to final surgical procedure, proportion of closed or covered wounds, and proportion of wounds that remained closed or covered at the 30-day follow-up. There were no statistically significant differences in the demographic profiles in the two cohorts except for a larger proportion of male patients (p = 0.004). There was no statistically significant difference in the surrogate outcomes with the exception of the time to final surgical procedure favoring normal saline (p = 0.038). The authors' results suggest that 0.9% normal saline may be as effective as an antiseptic (0.1% polyhexanide plus 0.1% betaine) for negative-pressure wound therapy with instillation for the adjunctive inpatient management of infected wounds. Therapeutic, II.

  9. EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa

    Science.gov (United States)

    Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.

    2016-01-01

    A comparison in the negative gauge pressure range was arranged in the period 2011 - 2012. A total of 14 laboratories participated in this comparison: BEV (Austria), CMI (Czech Republic), DANIAmet-FORCE (Denmark), EIM (Greece), HMI/FSB-LPM (Croatia), INM (Romania), IPQ (Portugal), LNE (France), MCCAA (Malta), METROSERT (Estonia), MIKES (Finland), MIRS/IMT/LMT (Slovenia), NSAI (Ireland) and UME (Turkey). The project was divided into two loops: Loop1, piloted by MIKES, and Loop2, piloted by LNE. The results of the two loops are reported separately: Loop1 results are presented in this paper. The transfer standard was Beamex MC5 no. 25516865 with internal pressure module INT1C, resolution 0.01 hPa. The nominal pressure range of the INT1C is -1000 hPa to +1000 hPa. The nominal pressure points for the comparison were 0 hPa, -200 hPa, -400 hPa, -600 hPa, -800 hPa and -950 hPa. The reference values and their uncertainties as well as the difference uncertainty between the laboratory results and the reference values were determined from the measurement data by Monte Carlo simulations. Stability uncertainty of the transfer standard was included in the final difference uncertainty. Degrees of equivalences and mutual equivalences between the laboratories were calculated. Each laboratory reported results for all twelve measurement points, which means that there were 168 reported values in total. Some 163 of the 168 values (97 %) agree with the reference values within the expanded uncertainties, with a coverage factor k = 2. Among the laboratories, four different methods were used to determine negative gauge pressure. It is concluded that special attention must be paid to the measurements and methods when measuring negative gauge pressures. There might be a need for a technical guide or a workshop that provides information about details and practices related to the measurements of negative gauge pressure, as well as differences between the different methods. The comparison is

  10. Nonlinear transient dynamic response of pressure relief valves for a negative containment system

    International Nuclear Information System (INIS)

    Aziz, T.S.; Duff, C.G.; Tang, J.H.K.

    1979-01-01

    The response of the piston for the postulated simultaneous effect of pressure and an earthquake is obtained for different parameters and accident conditions. Response quantities such as accelerations, displacements, rotations, diaphragm forces as well as opening time during a design basis earthquake are obtained. The results of the different analyses, as related to the functional operability of the valves, are evaluated and discussed. (orig.)

  11. Perceiving social pressure not to feel negative predicts depressive symptoms in daily life

    NARCIS (Netherlands)

    Dejonckheere, E.; Bastian, B.; Fried, E.I.; Murphy, S.C.; Kuppens, P.

    Background Western societies often overemphasize the pursuit of happiness, and regard negative feelings such as sadness or anxiety as maladaptive and unwanted. Despite this emphasis on happiness, the amount of people suffering from depressive complaints is remarkably high. To explain this apparent

  12. The Ambivalence of Challenge Stressors: Time Pressure Associated with Both Negative and Positive Well-Being

    Science.gov (United States)

    Widmer, Pascale S.; Semmer, Norbert K.; Kalin, Wolfgang; Jacobshagen, Nicola; Meier, Laurenz L.

    2012-01-01

    According to the challenge-hindrance model, challenge stressors contain both stressful and challenging aspects, hindrance stressors only stressful aspects. Typically, negative outcomes of challenge stressors refer to well-being (strain), positive outcomes to so-called work outcomes (e.g., productivity, intention to quit). As both effects occur…

  13. The acute effects of lower limb intermittent negative pressure on foot macro- and microcirculation in patients with peripheral arterial disease.

    Directory of Open Access Journals (Sweden)

    Øyvind Heiberg Sundby

    Full Text Available Intermittent negative pressure (INP applied to the lower leg and foot increases foot perfusion in healthy volunteers. The aim of the present study was to describe the effects of INP to the lower leg and foot on foot macro- and microcirculation in patients with lower extremity peripheral arterial disease (PAD.In this experimental study, we analyzed foot circulation during INP in 20 patients [median (range: 75 (63-84yrs] with PAD. One leg was placed inside an air-tight vacuum chamber connected to an INP-generator. During application of INP (alternating 10s of -40mmHg/7s of atmospheric pressure, we continuously recorded blood flow velocity in a distal foot artery (ultrasound Doppler, skin blood flow on the pulp of the first toes (laser Doppler, heart rate (ECG, and systemic blood pressure (Finometer. After a 5-min baseline sequence (no pressure, a 10-min INP sequence was applied, followed by 5-min post-INP (no pressure. To compare and quantify blood flow fluctuations between sequences, we calculated cumulative up-and-down fluctuations in arterial blood flow velocity per minute.Onset of INP induced an increase in arterial flow velocity and skin blood flow. Peak blood flow velocity was reached 3s after the onset of negative pressure, and increased 46% [(95% CI 36-57, P<0.001] above baseline. Peak skin blood flow was reached 2s after the onset of negative pressure, and increased 89% (95% CI 48-130, P<0.001 above baseline. Cumulative fluctuations per minute were significantly higher during INP-sequences compared to baseline [21 (95% CI 12-30cm/s/min to 41 (95% CI 32-51cm/s/min, P<0.001]. Mean INP blood flow velocity increased significantly ~12% above mean baseline blood flow velocity [(6.7 (95% CI 5.2-8.3cm/s to 7.5 (95% CI 5.9-9.1cm/s, P = 0.03].INP increases foot macro- and microcirculatory flow pulsatility in patients with PAD. Additionally, application of INP resulted in increased mean arterial blood flow velocity.

  14. Design of Capillary Flows with Spatially Graded Porous Films

    Science.gov (United States)

    Joung, Young Soo; Figliuzzi, Bruno Michel; Buie, Cullen

    2013-11-01

    We have developed a new capillary tube model, consisting of multi-layered capillary tubes oriented in the direction of flow, to predict capillary speeds on spatially graded porous films. Capillary flows through thin porous media have been widely utilized for small size liquid transport systems. However, for most media it is challenging to realize arbitrary shapes and spatially functionalized micro-structures with variable flow properties. Therefore, conventional media can only be used for capillary flows obeying Washburn's equation and the modifications thereof. Given this background, we recently developed a method called breakdown anodization (BDA) to produce highly wetting porous films. The resulting surfaces show nearly zero contact angles and fast water spreading speed. Furthermore, capillary pressure and spreading diffusivity can be expressed as functions of capillary height when customized electric fields are used in BDA. From the capillary tube model, we derived a general capillary flow equation of motion in terms of capillary pressure and spreading diffusivity. The theoretical model shows good agreement with experimental capillary flows. The study will provide novel design methodologies for paper-based microfluidic devices.

  15. Negative pressure of the environmental air in the cleaning area of the materials and sterilization center: a systematic review

    Directory of Open Access Journals (Sweden)

    Caroline Lopes Ciofi-Silva

    Full Text Available ABSTRACT Objective: to analyze the scientific evidence on aerosols generated during cleaning activities of health products in the Central Service Department (CSD and the impact of the negative pressure of the ambient air in the cleaning area to control the dispersion of aerosols to adjacent areas. Method: for this literature systematic review the following searches were done: search guidelines, manuals or national and international technical standards given by experts; search in the portal and databases PubMed, Scopus, CINAHL and Web of Science; and a manual search of scientific articles. Results: the five technical documents reviewed recommend that the CSD cleaning area should have a negative differential ambient air pressure, but scientific articles on the impact of this intervention were not found. The four articles included talked about aerosols formed after the use of a ultrasonic cleaner (an increased in the contamination especially during use and pressurized water jet (formation of smaller aerosols 5μm. In a study, the aerosols formed from contaminated the hot tap water with Legionella pneumophila were evaluated. Conclusions: there is evidence of aerosol formation during cleanup activities in CSD. Studies on occupational diseases of respiratory origin of workers who work in CSD should be performed.

  16. The Influence of the Bed with a Semiopen Hood on Bacteria Removal in a Negative-Pressure Isolation Room

    Directory of Open Access Journals (Sweden)

    Jeng-Min Huang

    2014-06-01

    Full Text Available This study numerically investigates the influence of a sickbed with a semiopened hood on bacteria removal in a negative-pressure isolation room. The parameters include air change rate, lying style, the length and height of hood, flow rate allotments, and the positions of outlets. The results show that the hood has excellent effect on the removal of contaminated air, which is much better than the case without hood. The flow field of patient's face up cough is very different from face side cough, and the contaminated air cannot be removed properly through one air outlet. There are three outlets on the hood, set straight above the patient's face and at both sides. The allotment of the exhaust flow rate of the upper outlet to that of side outlets is suggested to be 4: 6. When the total air change rate is above 6 ACH, the hood length has slight influence on pollutant removal. The increase of hood height has a negative impact when the patient coughs lying on back. When the side exhaust flow rate is high, the hood height has a slight impact for face side cough. The recommended air change rate for the negative-pressure ward with sickbed hood is above 5 ACH.

  17. Impact of microarousal associated with increased negative esophageal pressure in sleep-disordered breathing.

    Science.gov (United States)

    Sukegawa, Mayo; Noda, Akiko; Yasuda, Yoshinari; Nakata, Seiichi; Sugiura, Tatsuki; Miyata, Seiko; Honda, Kumiko; Hasegawa, Yoshinori; Nakashima, Tsutomu; Koike, Yasuo

    2009-11-01

    "Microarousals" during sleep have not been analyzed systematically. We investigated the importance of "microarousals" (lasting 1.5-3 s). Standard polysomnography including esophageal pressure (Pes) assessment was performed on ten patients (aged 54.0 +/- 5.0 years) with respiratory effort-related arousal > or =5/h. We measured the number of arousals per hour (American Sleep Disorders Association (ASDA) arousal index) and the number of microarousals lasting 1.5-3 s per hour (mASDA arousal index). On the night after the baseline sleep study, we performed overnight continuous positive airway pressure (CPAP) titration. mASDA arousals, characterized by lower Pes values, were observed more frequently in patients with sleep-disordered breathing. The Pes results did not differ significantly between ASDA and mASDA arousals (-15.6 +/- -5.0 vs -15.0 +/- -4.4 cmH(2)O). mASDA arousals were significantly improved by CPAP treatment (mASDA arousals, 82.6 +/- 60.1 vs 6.0 +/- 1.4/h). mASDA arousals were characterized by an increase in Pes. mASDA arousals are thus key to our understanding of clinical manifestations in patients with sleep-disordered breathing.

  18. Comparisons of negative pressure wound therapy and ultrasonic debridement for diabetic foot ulcers: a network meta-analysis.

    Science.gov (United States)

    Wang, Ruran; Feng, Yanhua; Di, Bo

    2015-01-01

    a network meta-analysis was performed to compare the strength and weakness of negative pressure wound therapy (NPWT) with ultrasound debridement (UD) as for diabetic foot ulcers (DFU). PubMed, Ovid EMBASE, Web of Science, Cochrane library databases, and Chinese Biomedical Literature Database were searched till February 2015. Clinical compared studies of negative pressure wound therapy and ultrasound debridement were enrolled. The primary efficacy outcomes included healed ulcers, reduction of ulcer areas and time to closure. Secondary amputation including major and minor amputations was used to assess the safety profile. Out of 715 studies, 32 were selected which enrolled 2880 diabetic patients. The pooled analysis revealed that NPWT including vacuum assisted closure (VAC) and vacuum sealing drainage (VSD) were as efficacious as ultrasound debridement improving healed ulcers, odds ratio, 0.86; 95% CI 0.28 to 2.6 and 1.2; 95% CI 0.38 to 4, respectively. However, both were better to standard wound care in wound healing patients. Compared with the standard wound care treated diabetic foot ulcers, NPWT and UD resulted in a significantly superior efficacy in time to wound closure and decrement in area of wound. No significances were observed between NPWT and UD groups in both indicators. Fewer patients tended to receive amputation in NPWT and UD groups compared to standard wound care group. The results of the network meta-analysis indicated that negative pressure wound therapy was similar to ultrasound debridement for diabetic foot ulcers, but better than standard wound care both in efficacy and safety profile.

  19. Comparisons of negative pressure wound therapy and ultrasonic debridement for diabetic foot ulcers: a network meta-analysis

    Science.gov (United States)

    Wang, Ruran; Feng, Yanhua; Di, Bo

    2015-01-01

    Objective: a network meta-analysis was performed to compare the strength and weakness of negative pressure wound therapy (NPWT) with ultrasound debridement (UD) as for diabetic foot ulcers (DFU). Methods: PubMed, Ovid EMBASE, Web of Science, Cochrane library databases, and Chinese Biomedical Literature Database were searched till February 2015. Clinical compared studies of negative pressure wound therapy and ultrasound debridement were enrolled. The primary efficacy outcomes included healed ulcers, reduction of ulcer areas and time to closure. Secondary amputation including major and minor amputations was used to assess the safety profile. Results: Out of 715 studies, 32 were selected which enrolled 2880 diabetic patients. The pooled analysis revealed that NPWT including vacuum assisted closure (VAC) and vacuum sealing drainage (VSD) were as efficacious as ultrasound debridement improving healed ulcers, odds ratio, 0.86; 95% CI 0.28 to 2.6 and 1.2; 95% CI 0.38 to 4, respectively. However, both were better to standard wound care in wound healing patients. Compared with the standard wound care treated diabetic foot ulcers, NPWT and UD resulted in a significantly superior efficacy in time to wound closure and decrement in area of wound. No significances were observed between NPWT and UD groups in both indicators. Fewer patients tended to receive amputation in NPWT and UD groups compared to standard wound care group. Conclusions: The results of the network meta-analysis indicated that negative pressure wound therapy was similar to ultrasound debridement for diabetic foot ulcers, but better than standard wound care both in efficacy and safety profile. PMID:26550165

  20. Topical negative pressure therapy Recent experience of the department of plastic surgery at Ibn Sina University Hospital, Rabat, Morocco

    Directory of Open Access Journals (Sweden)

    Abdelmoughit Echchaoui

    2014-12-01

    Full Text Available IntroductionThe topical negative pressure therapy (TNP is a non-invasive method to treat chronic and acute wounds locally, using a continuous or intermittent negative pressure.The objective of this study is to present the first experience of this type of treatment used in clinical cases in our department. By presenting these cases, we highlight indication and efficiency of this new technique applied in relatively complicated situations, at the same time it also allows a significant improvement in treating injuries and chronic wounds.Materials and methodsIn this study, we present the recent experience of the Department of Reconstructive and Plastic Surgery of the University Hospital Center of Avicenne in Rabat. This therapy was used for the first time this year (in 2014, in three young patients who presented with chronic wounds associated with local and general factors that are unfavorable for the healing process.ResultsIn all three of our cases we obtained highly satisfactory clinical results.TNP allows wounds to bud in a shorter time, as well as a fast healing by second intention due to controlled wound healing or split-skin graft without using flaps. This enables to decrease the margin of error, the time and the number of dressing replacements, and to reduce the length of hospital stay.ConclusionThis is an expensive and specific equipment. However, the cost-benefit ratio analysis shows that it is an essential method that should be part of our therapeutic strategies.Keywords: loss of substance, negative pressure, budding, healing.  

  1. Negative Pressure Wound Therapy in Infected Wound following Posterior Spinal Instrumentation using Simple Self-assembled System: A Case Report

    Directory of Open Access Journals (Sweden)

    CW Chang

    2014-07-01

    Full Text Available Postoperative wound infection in an instrumented spine patient is often disastrous. Management includes implant removal leading to spine instability. Negative pressure wound therapy (NPWT applied to the spine surgical wound is one of the wound care technique with successful results. We report a case of a man who sustained Chance fracture of Lumbar 1 (L1 vertebra treated with long segment posterior instrumentation, who unfortunately developed Extended-spectrum beta-lactamase (ESBL positive E. coli infection one month after the operation. After careful debridement of the wound, the implant became exposed. Three cycles of NPWT were applied and the wound healed with granulation tissue completely covering the implant, and thus negating the need to remove the implant. In conclusion, the NPWT is a good alternative in postoperative wound management especially in an instrumented spine patient.

  2. The Influence of the Bed with a Semiopen Hood on Bacteria Removal in a Negative-Pressure Isolation Room

    OpenAIRE

    Jeng-Min Huang; Hsiang-Tai Cheng

    2014-01-01

    This study numerically investigates the influence of a sickbed with a semiopened hood on bacteria removal in a negative-pressure isolation room. The parameters include air change rate, lying style, the length and height of hood, flow rate allotments, and the positions of outlets. The results show that the hood has excellent effect on the removal of contaminated air, which is much better than the case without hood. The flow field of patient's face up cough is very different from face side coug...

  3. A Unique Application of Negative Pressure Wound Therapy Used to Facilitate Patient Engagement in the Amputation Recovery Process.

    Science.gov (United States)

    Wise, Jessica; White, Alicia; Stinner, Daniel J; Fergason, John R

    2017-08-01

    Amputation rates during recent military conflicts were at an all-time high, but medical treatment of those amputations and attitudes of service members to get back to duty are also surging ahead. We present the cases of an active duty rescue C130 pilot with an above-the-knee amputation and a retired army sergeant with a below-the-knee amputation. Successful rehabilitation was augmented in both cases by using negative pressure incorporated in a custom prosthetic socket to accelerate incision closure, improve self-efficacy in wound care, and self-management, ultimately leading to faster recovery times, full engagement of the rehabilitation process, and return to active duty.

  4. Cost-effectiveness of negative pressure wound therapy in patients with many comorbidities and severe wounds of various etiology.

    Science.gov (United States)

    Driver, Vickie R; Eckert, Kristen A; Carter, Marissa J; French, Michael A

    2016-11-01

    This study analyzed a cross-section of patients with severe chronic wounds and multiple comorbidities at an outpatient wound clinic, with regard to the cost-effectiveness and cost-benefit of negative pressure wound therapy (intervention) vs. no negative pressure wound therapy (control) at 1 and 2 years. Medicare reimbursement charges for wound care were used to calculate costs. Amputation charges were assessed using diagnosis-related groups. Cost-benefit analysis was based on ulcer-free months and cost-effectiveness on quality-adjusted life-years. Undiscounted costs, benefits, quality-adjusted life-years, undiscounted and discounted incremental net health benefits, and incremental cost-effectiveness ratios were calculated for unmatched and matched cohorts. There were 150 subjects in the intervention group and 154 controls before matching and 103 subjects in each of the matched cohorts. Time to heal for the intervention cohort was significantly shorter compared to the controls (270 vs. 635 days, p = 1.0 × 10 -7 , matched cohorts). The intervention cohort had higher benefits and quality-adjusted life-year gains compared to the control cohort at years 1 and 2; by year 2, the gains were 68-73% higher. In the unmatched cohorts, the incremental net health benefit was $9,933 per ulcer-free month at year 2 for the intervention; the incremental cost-effectiveness ratio was -825,271 per quality-adjusted life-year gained (undiscounted costs and benefits). For the matched cohorts, the incremental net health benefits was only $1,371 per ulcer-free month for the intervention, but the incremental cost-effectiveness ratio was $366,683 per quality-adjusted life-year gained for year 2 (discounted costs and benefits). In a patient population with severe chronic wounds and serious comorbidities, negative pressure wound therapy resulted in faster healing wounds and was more cost-effective with greater cost-benefits than not using negative pressure wound therapy. Regarding overall

  5. Capillary Interactions between a Probe Tip and a Nanoparticle

    International Nuclear Information System (INIS)

    Li-Ning, Sun; Le-Feng, Wang; Wei-Bin, Rong

    2008-01-01

    To understand capillary interactions between probe tips and nanoparticles under ambient conditions, a theoretical model of capillary forces between them is developed based on the geometric relations. It is found that the contribution of surface tension force to the total capillary force attains to similar order of magnitude as the capillary pressure force in many cases. It is also shown that the tip shape and the radial distance of the meniscus have great influence on the capillary force. The capillary force decreases with the increasing separation distances, and the variance of the contact angles may change the magnitudes of capillary forces several times at large radial distances. The applicability of the symmetric meniscus approximation is discussed. (condensed matter: structure, mechanical and thermal properties)

  6. Hemodynamic responses to seated and supine lower body negative pressure - Comparison with +Gz acceleration

    Science.gov (United States)

    Polese, Alvese; Sandler, Harold; Montgomery, Leslie D.

    1992-01-01

    The hemodynamic responses to LBNP in seated subjects and in subjects in supine body positions were compared and were correlated with hemodynamic changes which occurred during a simulated (by centrifugation) Shuttle reentry acceleration with a slow onset rate of 0.002 G/s and during gradual onset exposures to +3 Gz and +4 Gz. Results demonstrate that seated LBNP at a level of -40 mm Hg can serve as a static simulator for changes in the heart rate and in mean blood pressure induced by gradual onset acceleration stress occurring during Shuttle reentry. The findings also provide a rationale for using LBNP during weightlessness as a means of imposing G-loading on the circulation prior to reentry.

  7. Porosity, single-phase permeability, and capillary pressure data from preliminary laboratory experiments on selected samples from Marker Bed 139 at the Waste Isolation Pilot Plant. Volume 1 of 3: Main report, appendix A

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, S.M.; Christian-Frear, T.

    1997-08-01

    Three groups of core samples from Marker Bed 139 of the Salado Formation at the Waste Isolation Pilot Plant (WIPP) were analyzed to provide data to support the development of numerical models used to predict the long-term hydrologic and structural response of the WIPP repository. These laboratory experiments, part of the FY93 Experimental Scoping Activities of the Salado Two-Phase Flow Laboratory Program, were designed to (1) generate WIPP-specific porosity and single-phase permeability data, (2) provide information needed to design and implement planned tests to measure two-phase flow properties, including threshold pressure, capillary pressure, and relative permeability, and (3) evaluate the suitability of using analog correlations for the Salado Formation to assess the long-term performance of the WIPP. This report contains a description of the boreholes core samples, the core preparation techniques used, sample sizes, testing procedures, test conditions, and results of porosity and single-phase permeability tests performed at three laboratories: TerraTek, Inc. (Salt Lake City, UT), RE/SPEC, Inc. (Rapid City, SD), and Core Laboratories-Special Core Analysis Laboratory (Carrollton, TX) for Rock Physics Associates. In addition, this report contains the only WIPP-specific two-phase-flow capillary-pressure data for twelve core samples. The WIPP-specific data generated in this laboratory study and in WIPP field-test programs and information from suitable analogs will form the basis for specification of single- and two-phase flow parameters for anhydrite markers beds for WIPP performance assessment calculations.

  8. Porosity, single-phase permeability, and capillary pressure data from preliminary laboratory experiments on selected samples from Marker Bed 139 at the Waste Isolation Pilot Plant. Volume 1 of 3: Main report, appendix A

    International Nuclear Information System (INIS)

    Howarth, S.M.; Christian-Frear, T.

    1997-08-01

    Three groups of core samples from Marker Bed 139 of the Salado Formation at the Waste Isolation Pilot Plant (WIPP) were analyzed to provide data to support the development of numerical models used to predict the long-term hydrologic and structural response of the WIPP repository. These laboratory experiments, part of the FY93 Experimental Scoping Activities of the Salado Two-Phase Flow Laboratory Program, were designed to (1) generate WIPP-specific porosity and single-phase permeability data, (2) provide information needed to design and implement planned tests to measure two-phase flow properties, including threshold pressure, capillary pressure, and relative permeability, and (3) evaluate the suitability of using analog correlations for the Salado Formation to assess the long-term performance of the WIPP. This report contains a description of the boreholes core samples, the core preparation techniques used, sample sizes, testing procedures, test conditions, and results of porosity and single-phase permeability tests performed at three laboratories: TerraTek, Inc. (Salt Lake City, UT), RE/SPEC, Inc. (Rapid City, SD), and Core Laboratories-Special Core Analysis Laboratory (Carrollton, TX) for Rock Physics Associates. In addition, this report contains the only WIPP-specific two-phase-flow capillary-pressure data for twelve core samples. The WIPP-specific data generated in this laboratory study and in WIPP field-test programs and information from suitable analogs will form the basis for specification of single- and two-phase flow parameters for anhydrite markers beds for WIPP performance assessment calculations

  9. Multiple capillary biochemical analyzer

    Science.gov (United States)

    Dovichi, N.J.; Zhang, J.Z.

    1995-08-08

    A multiple capillary analyzer allows detection of light from multiple capillaries with a reduced number of interfaces through which light must pass in detecting light emitted from a sample being analyzed, using a modified sheath flow cuvette. A linear or rectangular array of capillaries is introduced into a rectangular flow chamber. Sheath fluid draws individual sample streams through the cuvette. The capillaries are closely and evenly spaced and held by a transparent retainer in a fixed position in relation to an optical detection system. Collimated sample excitation radiation is applied simultaneously across the ends of the capillaries in the retainer. Light emitted from the excited sample is detected by the optical detection system. The retainer is provided by a transparent chamber having inward slanting end walls. The capillaries are wedged into the chamber. One sideways dimension of the chamber is equal to the diameter of the capillaries and one end to end dimension varies from, at the top of the chamber, slightly greater than the sum of the diameters of the capillaries to, at the bottom of the chamber, slightly smaller than the sum of the diameters of the capillaries. The optical system utilizes optic fibers to deliver light to individual photodetectors, one for each capillary tube. A filter or wavelength division demultiplexer may be used for isolating fluorescence at particular bands. 21 figs.

  10. Hemolysis During Open-Heart Surgery With Vacuum-Assisted Venous Drainage at Different Negative Pressures in Pediatric Patients Weighing Less Than 10 kilograms.

    Science.gov (United States)

    Kwak, Jae Gun; Lee, Jinkwon; Park, Minkyoung; Seo, Yu-Jin; Lee, Chang-Ha

    2017-03-01

    This study examined the degree of hemolysis during vacuum-assisted venous drainage at different negative pressures to identify an adequate negative pressure that provides effective venous drainage without significant hemolysis in open-heart surgery in children weighing less than 10 kg. Patients weighing less than 10 kg who underwent surgery for ventricular septal defect or atrial septal defect from 2011 to 2014 were enrolled. We used one of four negative pressures (20, 30, 40, or 60 mm Hg) for each patient. We measured haptoglobin, plasma hemoglobin, aspartate aminotransferase, and lactate dehydrogenase levels in the patients' blood three times perioperatively and determined the potential correlation between the change in each parameter with the level of negative pressure. Forty-six patients were enrolled in this study (mean age: 7.1 ± 7.0 months, mean body weight: 6.1 ± 1.8 kg). There were no significant differences according to the degree of negative pressure with respect to patient age, body weight, cardiopulmonary bypass (CPB) time, aorta cross-clamping time, blood flow during CPB, or lowest body temperature. All parameters that we measured reflected progression of hemolysis during CPB; however, the degree of change in the parameters did not correlate with negative pressure. In pediatric patients weighing less than 10 kg, the change in the degree of hemolysis did not differ with the amount of negative pressure. We may apply negative pressures up to 60 mm Hg without increasing the risk of hemolysis, with almost same the level of hemolysis using negative pressures of 20, 30, and 40 mm Hg for effective venous drainage and an ideal operative field during open-heart surgery.

  11. Impact of chemical peeling combined with negative pressure on human skin.

    Science.gov (United States)

    Kim, S J; Kang, I J; Shin, M K; Jeong, K H; Baek, J H; Koh, J S; Lee, S J

    2016-10-01

    In vivo changes in skin barrier function after chemical peeling with alpha hydroxyacids (AHAs) have been previously reported. However, the additional effects of physical treatment with chemical agents on skin barrier function have not been adequately studied. This study measured the degree of acute skin damage and the time required for skin barrier repair using non-invasive bioengineering methods in vivo with human skin to investigate the additional effect of a 4% AHA chemical jet accelerated at supersonic velocities. Thirteen female subjects (average age: 29.54 ± 4.86 years) participated in this study. The faces of the subjects were divided into half according to the block randomization design and were then assigned to receive AHA peeling alone or AHA peeling combined with pneumatic pressure on each side of the face. Transepidermal water loss (TEWL), skin colour and skin blood flow were evaluated at baseline and at 30 min, 2, 5 and 7 days after treatment. The TEWL and skin blood flow were significantly increased after 30 min in chemodermabrasion compared with chemical peeling alone (P peeling alone (P < 0.05). Chemodermabrasion can temporarily impair skin barriers, but it is estimated that it can enhance the skin barrier function after 7 days compared to the use of a chemical agent alone. In addition, chemodermabrasion has a more effective impact in the dermis and relatively preserves the skin barrier. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  12. The efficacy of negative pressure wound therapy in the management of lower extremity trauma: review of clinical evidence.

    Science.gov (United States)

    Kanakaris, N K; Thanasas, C; Keramaris, N; Kontakis, G; Granick, Mark S; Giannoudis, P V

    2007-12-01

    A large number of aids have been conceived and introduced into clinical practice (nutritional supplements, local dressings, technical innovations) aimed at facilitating and optimising wound healing in both acute and chronic wound settings. Among these advances, negative pressure wound therapy (NPWT) has been introduced during the last 30 years, and has been analysed in over 400 manuscripts of the English, Russian and German literature. Until very recently, vacuum assisted closure (VAC) (KCI, TX, USA) has been the only readily available commercial device that provides localised negative pressure to the wound and is the predominant agent used to deliver NPWT featured in this review. We conducted a comprehensive review of the existing clinical evidence of the English literature on the applications of NPWT in the acute setting of trauma and burns of the lower extremity. Overall, 16 clinical studies have been evaluated and scrutinised as to the safety and the efficacy of this adjunct therapy in the specific environment of trauma. Effectiveness was comparable to the standard dressing and wound coverage methods. The existing clinical evidence justifies its application in lower limb injuries associated with soft tissue trauma.

  13. Measurement of negative ion mobility in O2 at high pressures using a point plate gap as an ion detector

    International Nuclear Information System (INIS)

    Okuyama, Y; Kimura, T; Suzuki, S; Itoh, H

    2012-01-01

    This paper describes the experimental results for negative ion mobility in O 2 at 0.5-2.0 atm. The ion mobility is observed using a high-pressure ion drift tube with a positive corona gap (Geiger counter), which is constructed from a point plate gap and acts as a negative ion detector. The variation of waveforms in the burst pulse is observed by varying the voltage applied to the ion detector to find the optimum voltage that must be applied across the ion detector in O 2 . This is investigated carefully to ensure the precise determination of mobility. The distortion of the electric field near the mesh electrode, which operates as the cathode of the ion detector and as the anode of the ion drift gap, is then examined to determine the optimum applied voltage to suppress its effect on the measurement of mobility. The mobility is subsequently measured at a reduced electric field intensity of 2.83 × 10 -3 to 2.83. The observed mobility of 2.31 ± 0.03 cm 2 V -1 s -1 in O 2 is concluded to be that of O 2 - . This value is also obtained in experiments over a wide range of gas pressures (0.5-2.0 atm) and drift lengths (1.00-9.00 cm). The mobilities of O 3 - and O - are also obtained experimentally. (paper)

  14. Intermittent negative pressure wound therapy with instillation for the treatment of persistent periprosthetic hip infections: a report of two cases

    Directory of Open Access Journals (Sweden)

    Söylemez MS

    2016-02-01

    Full Text Available Mehmet Salih Söylemez,1 Korhan Özkan,2 Bülent Kılıç,3 Samet Erinç41Department of Orthopaedics and Traumatology, Bingöl State Hospital, Bingöl, 2Department of Orthopaedics and Traumatology, Faculty of Medicine, Medeniyet University, Istanbul, 3Department of Orthopaedics and Traumatology, Orthopaedic Surgery Clinic, Istanbul Gelişim University, Tekirdağ, 4Department of Orthopaedics and Traumatology, Istanbul Medeniyet University, Göztepe Training and Research Hospital, Istanbul, TurkeyAbstract: Intermittent negative pressure wound therapy with instillation (NPWTi is starting to be used successfully to treat early periprosthetic infections of endoprostheses. However, few articles have reported the outcome of treatment with intermittent NPWTi for late persistent periprosthetic infections of the hip. In this study, we report two cases who underwent several rounds of radical wound debridement for the treatment of a late persistent periprosthetic infection of the hip. Intermittent NPWTi was used in both cases. Patients were treated successfully and there was no recurrence after 3 and 1 years of follow-up, respectively.Keywords: negative pressure, vacuum-assisted, periprosthetic infection, hip

  15. Microgravity Investigation of Capillary Driven Imbibition

    Science.gov (United States)

    Dushin, V. R.; Nikitin, V. F.; Smirnov, N. N.; Skryleva, E. I.; Tyurenkova, V. V.

    2018-05-01

    The goal of the present paper is to investigate the capillary driven filtration in porous media under microgravity conditions. New mathematical model that allows taking into account the blurring of the front due to the instability of the displacement that is developing at the front is proposed. The constants in the mathematical model were selected on the basis of the experimental data on imbibition into unsaturated porous media under microgravity conditions. The flow under the action of a combination of capillary forces and a constant pressure drop or a constant flux is considered. The effect of capillary forces and the type of wettability of the medium on the displacement process is studied. A criterion in which case the capillary effects are insignificant and can be neglected is established.

  16. Mixed Capillary Venous Retroperitoneal Hemangioma

    Directory of Open Access Journals (Sweden)

    Mohit Godar

    2013-01-01

    Full Text Available We report a case of mixed capillary venous hemangioma of the retroperitoneum in a 61-year-old man. Abdominal ultrasonography showed a mass to be hypoechoic with increased flow in color Doppler imaging. Dynamic contrast-enhanced computed tomography revealed a centripetal filling-in of the mass, located anterior to the left psoas muscle at the level of sacroiliac joint. On the basis of imaging features, preoperative diagnosis of hemangioma was considered and the mass was excised by laparoscopic method. Immunohistochemical studies were strongly positive for CD31 and CD34, and negative for calretinin, EMA, WT1, HMB45, Ki67, synaptophysin, and lymphatic endothelial cell marker D2–40. Histologically, the neoplasm was diagnosed as mixed capillary venous hemangioma.

  17. Relationship quality: effects on ambulatory blood pressure and negative affect in a biracial sample of men and women.

    Science.gov (United States)

    Grewen, Karen M; Girdler, Susan S; Light, Kathleen C

    2005-06-01

    Prospective studies link marriage to better cardiovascular health, but marital dissatisfaction and discord predict increased rates of hypertension, higher blood pressure (BP), greater reactivity to stress, and left ventricular mass. To determine and compare effects of partner status and relationship quality on 24-h BP, urinary norepinephrine and cortisol, and self-reported stress and negative affect. Ambulatory BP (ABP) and 24-h urine collections were obtained during a typical work day in 325 adults, including 139 African Americans (AAs). Participants cohabiting with a spouse or partner were classified into high, intermediate and low relationship quality (RQ) groups and compared to those without partners (Alone). Mean ABP was nearly identical in participants with versus without partners (125.7/76.9 versus 125.9/76.7 mmHg). High RQ subjects had lower mean waking ABP than intermediate/low RQ and Alone groups [systolic blood pressure (SBP), F=3.45; diastolic blood pressure (DBP), F=3.38, P-values affect and stress than all other groups (Paffect and stress than partner status. High RQ is linked to lower ABP across race and gender. This reduced ABP may be due, in part, to the stress buffering effects of better RQ and/or the stress enhancing effects of poor RQ.

  18. Effect of Negative Pressure on Proliferation, Virulence Factor Secretion, Biofilm Formation, and Virulence-Regulated Gene Expression of Pseudomonas aeruginosa In Vitro

    Directory of Open Access Journals (Sweden)

    Guo-Qi Wang

    2016-01-01

    Full Text Available Objective. To investigate the effect of negative pressure conditions induced by NPWT on P. aeruginosa. Methods. P. aeruginosa was cultured in a Luria–Bertani medium at negative pressure of −125 mmHg for 24 h in the experimental group and at atmospheric pressure in the control group. The diameters of the colonies of P. aeruginosa were measured after 24 h. ELISA kit, orcinol method, and elastin-Congo red assay were used to quantify the virulence factors. Biofilm formation was observed by staining with Alexa Fluor® 647 conjugate of concanavalin A (Con A. Virulence-regulated genes were determined by quantitative RT-PCR. Results. As compared with the control group, growth of P. aeruginosa was inhibited by negative pressure. The colony size under negative pressure was significantly smaller in the experimental group than that in the controls (p<0.01. Besides, reductions in the total amount of virulence factors were observed in the negative pressure group, including exotoxin A, rhamnolipid, and elastase. RT-PCR results revealed a significant inhibition in the expression level of virulence-regulated genes. Conclusion. Negative pressure could significantly inhibit the growth of P. aeruginosa. It led to a decrease in the virulence factor secretion, biofilm formation, and a reduction in the expression level of virulence-regulated genes.

  19. Intramedullary capillary haemangioma.

    LENUS (Irish Health Repository)

    Kelleher, T

    2012-02-03

    Intramedullary capillary haemangioma is extremely rare and only four cases have been previously reported. We describe a further case, outlining the clinical, radiological, surgical and pathological features.

  20. Chromatographic selectivity of poly(alkyl methacrylate-co-divinylbenzene) monolithic columns for polar aromatic compounds by pressure-driven capillary liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shu-Ling; Wang, Chih-Chieh; Fuh, Ming-Ren, E-mail: msfuh@scu.edu.tw

    2016-10-05

    In this study, divinylbenzene (DVB) was used as the cross-linker to prepare alkyl methacrylate (AlMA) monoliths for incorporating π-π interactions between the aromatic analytes and AlMA-DVB monolithic stationary phases in capillary LC analysis. Various AlMA/DVB ratios were investigated to prepare a series of 30% AlMA-DVB monolithic stationary phases in fused-silica capillaries (250-μm i.d.). The physical properties (such as porosity, permeability, and column efficiency) of the synthesized AlMA-DVB monolithic columns were investigated for characterization. Isocratic elution of phenol derivatives was first employed to evaluate the suitability of the prepared AlMA-DVB columns for small molecule separation. The run-to-run (0.16–1.20%, RSD; n = 3) and column-to-column (0.26–2.95%, RSD; n = 3) repeatabilities on retention times were also examined using the selected AlMA-DVB monolithic columns. The π-π interactions between the aromatic ring and the DVB-based stationary phase offered better recognition on polar analytes with aromatic moieties, which resulted in better separation resolution of aromatic analytes on the AlMA-DVB monolithic columns. In order to demonstrate the capability of potential environmental and/or food safety applications, eight phenylurea herbicides with single benzene ring and seven sulfonamide antibiotics with polyaromatic moieties were analyzed using the selected AlMA-DVB monolithic columns. - Highlights: • First investigation on chromatographic selectivity of AlMA-DVB monolithic columns. • Good run-to-run/column-to-column repeatability (<3%) on AlMA-DVB monolithic columns. • Efficient separation of phenylurea herbicides and sulfonamides on AlMA-DVB columns.

  1. DC negative corona discharge in atmospheric pressure helium: transition from the corona to the ‘normal’ glow regime

    International Nuclear Information System (INIS)

    Hasan, Nusair; Farouk, Bakhtier; Antao, Dion S

    2014-01-01

    Direct current (dc) negative corona discharges in atmospheric pressure helium are simulated via detailed numerical modeling. Simulations are conducted to characterize the discharges in atmospheric helium for a pin plate electrode configuration. A self-consistent two-dimensional hybrid model is developed to simulate the discharges and the model predictions are validated with experimental measurements. The discharge model considered consists of momentum and energy conservation equations for a multi-component (electrons, ions, excited species and neutrals) gas mixture, conservation equations for each component of the mixture and state relations. A drift–diffusion approximation for the electron and the ion fluxes is used. A model for the external circuit driving the discharge is also considered and solved along with the discharge model. Many of the key features of a negative corona discharge, namely non-linear current–voltage characteristics, spatially flat cathode current density and glow-like discharge in the high current regime are displayed in the predictions. A transition to the ‘normal’ glow discharge from the corona discharge regime is also observed. The transition is identified from the calculated current–voltage characteristic curve and is characterized by the radial growth of the negative glow and the engulfment of the cathode wire. (paper)

  2. Mixed Fluid Conditions: Capillary Phenomena

    KAUST Repository

    Santamarina, Carlos

    2017-07-06

    Mixed fluid phenomena in porous media have profound implications on soil-atmosphere interaction, energy geotechnology, environmental engineering and infrastructure design. Surface tension varies with pressure, temperature, solute concentration, and surfactant concentration; on the other hand, the contact angle responds to interfacial tensions, surface topography, invasion velocity, and chemical interactions. Interfaces are not isolated but interact through the fluid pressure and respond to external fields. Jumps, snap-offs and percolating wetting liquids along edges and crevices are ubiquitous in real, non-cylindrical porous networks. Pore- and macroscale instabilities together with pore structure variability-and-correlation favor fluid trapping and hinder recovery efficiency. The saturation-pressure characteristic curve is affected by the saturation-history, flow-rate, the mechanical response of the porous medium, and time-dependent reactive and diffusive processes; in addition, there are salient differences between unsaturation by internal gas nucleation and gas invasion. Capillary forces add to other skeletal forces in the porous medium and can generate open-mode discontinuities when the capillary entry pressure is high relative to the effective stress. Time emerges as an important variable in mixed-fluid conditions and common quasi-static analyses may fail to capture the system response.

  3. Comprehensive protein profiling by multiplexed capillary zone electrophoresis using cross-linked polyacrylamide coated capillaries.

    Science.gov (United States)

    Liu, Shaorong; Gao, Lin; Pu, Qiaosheng; Lu, Joann J; Wang, Xingjia

    2006-02-01

    We have recently developed a new process to create cross-linked polyacrylamide (CPA) coatings on capillary walls to suppress protein-wall interactions. Here, we demonstrate CPA-coated capillaries for high-efficiency (>2 x 10(6) plates per meter) protein separations by capillary zone electrophoresis (CZE). Because CPA virtually eliminates electroosmotic flow, positive and negative proteins cannot be analyzed in a single run. A "one-sample-two-separation" approach is developed to achieve a comprehensive protein analysis. High throughput is achieved through a multiplexed CZE system.

  4. The concept of negative pressure wound therapy (NPWT after poststernotomy mediastinitis – a single center experience with 54 patients

    Directory of Open Access Journals (Sweden)

    Vogt Peter M

    2009-01-01

    Full Text Available Abstract Deep sternal infections, also known as poststernotomy mediastinitis, are a rare but often fatal complication in cardiac surgery. They are a cause of increased morbidity and mortality and have a significant socioeconomic aspect concerning the health system. Negative pressure wound therapy (NPWT followed by muscular pectoralis plasty is a quite new technique for the treatment of mediastinitis after sternotomy. Although it could be demonstrated that this technique is at least as safe and reliable as other techniques for the therapy of deep sternal infections, complications are not absent. We report about our experiences and complications using this therapy in a set of 54 patients out of 3668 patients undergoing cardiac surgery in our institution between January 2005 and April 2007.

  5. The concept of negative pressure wound therapy (NPWT) after poststernotomy mediastinitis--a single center experience with 54 patients.

    Science.gov (United States)

    Ennker, Ina C; Malkoc, Anita; Pietrowski, Detlef; Vogt, Peter M; Ennker, Juergen; Albert, Alexander

    2009-01-12

    Deep sternal infections, also known as poststernotomy mediastinitis, are a rare but often fatal complication in cardiac surgery. They are a cause of increased morbidity and mortality and have a significant socioeconomic aspect concerning the health system. Negative pressure wound therapy (NPWT) followed by muscular pectoralis plasty is a quite new technique for the treatment of mediastinitis after sternotomy. Although it could be demonstrated that this technique is at least as safe and reliable as other techniques for the therapy of deep sternal infections, complications are not absent. We report about our experiences and complications using this therapy in a set of 54 patients out of 3668 patients undergoing cardiac surgery in our institution between January 2005 and April 2007.

  6. Experience with the vacuum assisted closure negative pressure technique in the treatment of non-healing diabetic and dysvascular wounds.

    Science.gov (United States)

    Clare, Michael P; Fitzgibbons, Timothy C; McMullen, Scott T; Stice, R Colleen; Hayes, Dennis F; Henkel, Loree

    2002-10-01

    The purpose of this study is to report our experience with the Vacuum Assisted Closure (VAC) negative pressure technique in patients with non-healing wounds of the foot, ankle, and lower limb. We retrospectively reviewed 17 patients with non-healing wounds of the lower extremity who underwent treatment using the Vacuum Assisted Closure (VAC) device. Thirteen of 17 (76%) had diabetes mellitus, nine of whom were insulin-dependent, and 10 of whom had associated peripheral neuropathy. Eight of 17 (47%) had severe peripheral vascular disease. All had failed previous management with serial wound debridements and dressing changes; 15 of 17 (88%) had previously completed at least one course of oral antibiotics. Thirteen of 17 (76%) had previously undergone operative irrigation and debridement of the wounds; six of 17 (35%) had previously undergone revascularization procedures of the involved extremity. Five of 17 (29%) had wounds necessitating an amputation procedure prior to the present treatment; seven of 17 (41%) had failed treatment with local growth factors prior to the present treatment. Average length of treatment with the VAC device was 8.2 weeks. Fourteen of 17 (82%) wounds successfully healed; four underwent split-thickness skin grafting for wound closure; four were briefly treated with local growth factors; six were treated with only dressing changes following VAC treatment. Three of 17 (18%) wounds failed VAC treatment; all three patients had diabetes and had wounds located in the midfoot or forefoot; two of three had severe peripheral vascular disease. Our results indicate that the Vacuum Assisted Closure negative pressure technique is emerging as an acceptable option for wound care of the lower extremity. Not all patients are candidates for such treatment; those patients with severe peripheral vascular disease or smaller forefoot wounds may be best treated by other modalities. Larger wounds seem to be better suited for skin grafting or two-stage primary

  7. Apical negative pressure irrigation versus syringe irrigation: a systematic review of cleaning and disinfection of the root canal system.

    Science.gov (United States)

    Konstantinidi, E; Psimma, Z; Chávez de Paz, L E; Boutsioukis, C

    2017-11-01

    The aim of this study was to systematically review and critically analyse the published data on the treatment outcome (primary outcome) and on the cleaning and disinfection of root canals (secondary outcomes) achieved by negative pressure irrigation as compared to syringe irrigation. An electronic search was conducted in EMBASE, LILACS, PubMed, SciELO, Scopus and Web of Knowledge using both free-text keywords and controlled vocabulary. Additional studies were sought through hand searching of endodontic journals and of the relevant chapters of endodontic textbooks. No language restriction was imposed. The retrieved studies were screened by two reviewers according to predefined criteria. Included studies were critically appraised and the extracted data were arranged in tables. The electronic search and hand search retrieved 489 titles. One clinical study and 14 in vitro studies were finally included in the review; none of these studies assessed treatment outcome, four studies assessed the antimicrobial effect, seven studies evaluated the removal of pulp tissue remnants, and four studies investigated the removal of hard tissue debris or both hard tissue debris and pulp tissue remnants. Poor standardization and description of the protocols was evident. Inconclusive results were reported about the cleaning and disinfection accomplished by the two irrigation methods. Negative pressure irrigation was more effective under certain conditions when compared to suboptimal syringe irrigation; however, the variability of the protocols hindered quantitative synthesis. There is insufficient evidence to claim general superiority of any one of these methods. The level of the available evidence is low, and the conclusions should be interpreted with caution. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Experimental evidence for negative turgor pressure in small leaf cells of Robinia pseudoacacia L versus large cells of Metasequoia glyptostroboides Hu et W.C.Cheng. 1. Evidence from pressure-volume curve analysis of dead tissue.

    Science.gov (United States)

    Yang, Dongmei; Pan, Shaoan; Ding, Yiting; Tyree, Melvin T

    2017-03-01

    This paper provides a mini-review of evidence for negative turgor pressure in leaf cells starting with experimental evidence in the late 1950s and ending with biomechanical models published in 2014. In the present study, biomechanical models were used to predict how negative turgor pressure might be manifested in dead tissue, and experiments were conducted to test the predictions. The main findings were as follows: (i) Tissues killed by heating to 60 or 80 °C or by freezing in liquid nitrogen all became equally leaky to cell sap solutes and all seemed to pass freely through the cell walls. (ii) Once cell sap solutes could freely pass the cell walls, the shape of pressure-volume curves was dramatically altered between living and dead cells. (iii) Pressure-volume curves of dead tissue seem to measure negative turgor defined as negative when inside minus outside pressure is negative. (iv) Robinia pseudoacacia leaves with small palisade cells had more negative turgor than Metasequoia glyptostroboides with large cells. (v) The absolute difference in negative turgor between R. pseudoacacia and M. glyptostroboides approached as much as 1.0 MPa in some cases. The differences in the manifestation of negative turgor in living versus dead tissue are discussed. © 2016 John Wiley & Sons Ltd.

  9. The effect of blood volume loss on cardiovascular response to lower body negative pressure using a mathematical model

    Science.gov (United States)

    Karam, E. H.; Srinivasan, R. S.; Charles, J. B.; Fortney, S. M.

    1994-01-01

    Different mathematical models of varying complexity have been proposed in recent years to study the cardiovascular (CV) system. However, only a few of them specifically address the response to lower body negative pressure (LBNP), a stress that can be applied in weightlessness to predict changes in orthostatic tolerance. Also, the simulated results produced by these models agree only partially with experimental observations. In contrast, the model proposed by Melchior et al., and modified by Karam et al. is a simple representation of the CV system capable of accurately reproducing observed LBNP responses up to presyncopal levels. There are significant changes in LBNP response due to a loss of blood volume and other alterations that occur in weightlessness and related one-g conditions such as bedrest. A few days of bedrest can cause up to 15% blood volume loss (BVL), with consequent decreases in both stroke volume and cardiac output, and increases in heart rate, mean arterial pressure, and total peripheral resistance. These changes are more pronounced at higher levels of LBNP. This paper presents the results of a simulation study using our CV model to examine the effect of BVL on LBNP response.

  10. Origin of superconductivity in KFe2As2 under positive and negative pressures and relation to other Fe-based families

    Science.gov (United States)

    Valenti, Roser

    KFe2As2 shows an intricate behavior as a function of pressure. At ambient pressure the system is superconductor with a low critical temperature Tc=3.4 K and follows a V-shaped pressure dependence of Tc for moderate pressures with a local minimum at a pressure of 1.5 GPa. Under high pressures Pc=15 GPa, KFe2As2 exhibits a structural phase transition from a tetragonal to a collapsed tetragonal phase accompanied by a boost of the superconducting critical temperature up to 12 K. On the other hand, negative pressures realized through substitution of K by Cs or Rb decrease Tc down to 2.25K. In this talk we will discuss recent progress on the understanding of the microscopic origin of this pressure-dependent behavior by considering a combination of ab initio density functional theory with dynamical mean field theory and spin fluctuation theory calculations. We will argue that a Lifshitz transition associated with the structural collapse changes the pairing symmetry from d-wave (tetragonal) to s+/- (collapsed tetragonal) at high pressures while at ambient and negative pressures correlation effects appear to be detrimental for superconductivity. Further, we shall establish cross-links to the chalcogenide family, in particular FeSe under pressure. The Deutsche Forschungsgemeinschaft (DFG) is gratefully acknowledged for financial support.

  11. Experimental and numerical studies of choked flow through adiabatic and diabatic capillary tubes

    International Nuclear Information System (INIS)

    Deodhar, Subodh D.; Kothadia, Hardik B.; Iyer, K.N.; Prabhu, S.V.

    2015-01-01

    Capillary tubes are extensively used in several cooling applications like refrigeration, electronic cooling etc. Local pressure variation in adiabatic straight capillary tube (mini channel) is studied experimentally and numerically with R134a as the working fluid. Experiments are performed on two straight capillary tubes. It is found that the diameter is the most sensitive design parameter of the capillary tube. Experiments are performed on five helically coiled capillary tubes to quantify the effect of pitch and curvature of helically coiled capillary tube on the pressure drop. Non dimensionalized factor to account coiling of capillary tube is derived to calculate mass flow rate in helically coiled capillary tubes. Flow visualization in adiabatic capillary tube confirms the bubbly nature of two phase flow. Numerical and experimental investigations in diabatic capillary tube suggest that the use of positive displacement pump and choking at the exit of the channel ensures flow stability. - Highlights: • Model is developed to design capillary tube in adiabatic and diabatic condition. • Effect of coil curvature on pressure drop is studied experimentally. • Correlation is developed to predict mass flow rate in helical capillary tubes. • Flow visualization is carried out to check the type of two phase flow. • Effect of choked flow on diabatic capillary tubes is studied experimentally.

  12. Simulation of capillary bridges between nanoscale particles.

    Science.gov (United States)

    Dörmann, Michael; Schmid, Hans-Joachim

    2014-02-04

    Capillary forces are very important as they exceed in general other adhesion forces. But at the same time the exact calculation of these forces is very complex, so often assumptions and approximations are used. Previous research was done with regard to micrometer sized particles, but the behavior of nanoscale particles is different. Hence, the results for micrometer sized particles cannot be directly transferred when considering nanoscale particles. Therefore, a simulation method was developed to calculate numerically the shape of a rotationally symmetrical capillary bridge between two spherical particles or a particle and a plate. The capillary bridge in the gap between the particles is formed due to capillary condensation and is in thermodynamic equilibrium with the gas phase. Hence the Kelvin equation and the Young-Laplace equation can be used to calculate the profile of the capillary bridge, depending on the relative humidity of the surrounding air. The bridge profile consists of several elements that are determined consecutively and interpolated linearly. After the shape is determined, the volume and force, divided into capillary pressure force and surface tension force, can be calculated. The validation of this numerical model will be shown by comparison with several different analytical calculations for micrometer-sized particles. Furthermore, it is demonstrated that two often used approximations, (1) the toroidal approximation and (2) the use of an effective radius, cannot be used for nanoscale particles without remarkable mistake. It will be discussed how the capillary force and its components depend on different parameters, like particle size, relative humidity, contact angle, and distance, respectively. The rupture of a capillary bridge due to particle separation will also be presented.

  13. Global model analysis of negative ion generation in low-pressure inductively coupled hydrogen plasmas with bi-Maxwellian electron energy distributions

    International Nuclear Information System (INIS)

    Huh, Sung-Ryul; Kim, Nam-Kyun; Jung, Bong-Ki; Chung, Kyoung-Jae; Hwang, Yong-Seok; Kim, Gon-Ho

    2015-01-01

    A global model was developed to investigate the densities of negative ions and the other species in a low-pressure inductively coupled hydrogen plasma with a bi-Maxwellian electron energy distribution. Compared to a Maxwellian plasma, bi-Maxwellian plasmas have higher populations of low-energy electrons and highly vibrationally excited hydrogen molecules that are generated efficiently by high-energy electrons. This leads to a higher reaction rate of the dissociative electron attachment responsible for negative ion production. The model indicated that the bi-Maxwellian electron energy distribution at low pressures is favorable for the creation of negative ions. In addition, the electron temperature, electron density, and negative ion density calculated using the model were compared with the experimental data. In the low-pressure regime, the model results of the bi-Maxwellian electron energy distributions agreed well quantitatively with the experimental measurements, unlike those of the assumed Maxwellian electron energy distributions that had discrepancies

  14. Nasal Lobular Capillary Hemangioma

    Directory of Open Access Journals (Sweden)

    Prashant Patil

    2013-01-01

    Full Text Available Nasal lobular capillary hemangioma is a rare benign tumor of the paranasal sinuses. This lesion is believed to grow rapidly in size over time. The exact etiopathogenesis is still a dilemma. We discuss a case of nasal lobular capillary hemangioma presenting with a history of epistaxis. Contrast enhanced computed tomography of paranasal sinuses revealed an intensely enhancing soft-tissue mass in the left nasal cavity and left middle and inferior meati with no obvious bony remodeling or destruction. We present imaging and pathologic features of nasal lobular capillary hemangioma and differentiate it from other entities like nasal angiofibroma.

  15. The Relationship Between Microscopic Grain Surface Structure and the Dynamic Capillary-Driven Advance of Water Films over Individual Dry Natural Sand Grains

    Science.gov (United States)

    Kibbey, T. C. G.; Adegbule, A.; Yan, S.

    2017-12-01

    The movement of nonvolatile solutes in unsaturated porous media at low water contents depends on transport in surface-associated water films. The focus of the work described here was on studying solute movement in water films advancing by capillary forces over initially-dry grain surfaces, to understand how microscopic surface roughness features influence the initial velocity of water film advance. For this work, water containing a non-adsorbing conservative tracer was used to track the movement of advancing water films. A stainless steel capillary tube connected to an external reservoir a fixed distance below the grain surface was used to transmit solution to the grain surface under negative pressure (positive capillary pressure), consistent with conditions that might be expected in the unsaturated zone. The small internal diameter of the capillary prevents solution from draining out of the capillary back into the reservoir. When the capillary is contacted with a grain surface, capillary forces that result from contact between the fluid and the rough grain surface cause water films to wick across the grain surface. Multiple experiments were conducted on the same grain, rotating the grain and varying the capillary contact point around the circumference of the grain. Imaging was conducted at fixed intervals using an automated Extended Depth of Field (EDF) imaging system, and images were analyzed to determine initial velocity. Grain surfaces were then characterized through scanning electron microscope (SEM) imaging, using a hybrid stereoscopic reconstruction method designed to extract maximum detail in creating elevation maps of geologic surfaces from tilted pairs of SEM images. The resulting elevation maps were used to relate surface roughness profiles around the grain with initial velocities. Results suggest that velocity varies significant with contact point around an individual grain, and correlates quantitatively with the local grain surface structure

  16. Evaluation of negative-pressure wound therapy for patients with diabetic foot ulcers: systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Liu S

    2017-04-01

    Full Text Available Si Liu,1 Chao-zhu He,1 Yan-ting Cai,1 Qiu-ping Xing,1 Ying-zhen Guo,1 Zhi-long Chen,1 Ji-liang Su,1 Li-ping Yang2 1School of Nursing, Nanchang University, 2Department of Endocrinology, The Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China Objectives: The aim of this study was to perform an updated systematic review and meta-analysis to assess the clinical efficacy, safety, and cost-effectiveness of negative-pressure wound therapy (NPWT in the treatment of diabetic foot ulcers (DFUs.Methods: We searched the Cochrane Library, MEDLINE, EMBASE, Ovid, and Chinese Biological Medicine databases up to June 30, 2016. We also manually searched the articles from reference lists of the retrieved articles, which used the NPWT system in studies of vacuum-assisted closure therapy. Studies were identified and selected, and two independent reviewers extracted data from the studies.Results: A total of eleven randomized controlled trials, which included a total of 1,044 patients, were selected from 691 identified studies. Compared with standard dressing changes, NPWT had a higher rate of complete healing of ulcers (relative risk, 1.48; 95% confidence interval [CI]: 1.24–1.76; P<0.001, shorter healing time (mean difference, −8.07; 95% CI: −13.70–−2.45; P=0.005, greater reduction in ulcer area (mean difference, 12.18; 95% CI: 8.50–15.86; P<0.00001, greater reduction in ulcer depth (mean difference, 40.82; 95% CI: 35.97–45.67; P<0.00001, fewer amputations (relative risk, 0.31; 95% CI: 0.15–0.62; P=0.001, and no effect on the incidence of treatment-related adverse effects (relative risk, 1.12; 95% CI: 0.66–1.89; P=0.68. Meanwhile, many analyses showed that the NPWT was more cost-effective than standard dressing changes.Conclusion: These results indicate that NPWT is efficacious, safe, and cost-effective in treating DFUs. Keywords: diabetic foot ulcers, negative-pressure wound therapy, complete wound closure, amputation, meta

  17. RESTING SYMPATHETIC BAROREFLEX SENSITIVITY IN SUBJECTS WITH LOW AND HIGH TOLERANCE TO CENTRAL HYPOVOLEMIA INDUCED BY LOWER BODY NEGATIVE PRESSURE

    Directory of Open Access Journals (Sweden)

    Carmen eHinojosa-Laborde

    2014-06-01

    Full Text Available Central hypovolemia elicited by orthostasis or hemorrhage triggers sympathetically-mediated baroreflex responses to maintain organ perfusion; these reflexes are less sensitive in patients with orthostatic intolerance, and during conditions of severe blood loss, may result in cardiovascular collapse (decompensatory or circulatory shock. The ability to tolerate central hypovolemia is variable and physiological factors contributing to tolerance are emerging. We tested the hypothesis that resting muscle sympathetic nerve activity (MSNA and sympathetic baroreflex sensitivity (BRS are attenuated in male and female subjects who have low tolerance (LT to central hypovolemia induced by lower body negative pressure (LBNP. MSNA and diastolic arterial pressure (DAP were recorded in 47 human subjects who subsequently underwent LBNP to tolerance (onset of presyncopal symptoms. LT subjects experienced presyncopal symptoms prior to completing LBNP of -60 mm Hg, and subjects with high tolerance (HT experienced presyncopal symptoms after completing LBNP after -60 mmHg. Contrary to our hypothesis, resting MSNA burst incidence was not different between LT and HT subjects, and was not related to time to presyncope. BRS was assessed as the slope of the relationship between spontaneous fluctuations in DAP and MSNA during 5 min of supine rest. MSNA burst incidence/DAP correlations were greater than or equal to 0.5 in 37 subjects (LT: n= 9; HT: n=28, and BRS was not different between LT and HT (-1.8 ± 0.3 vs. -2.2 ± 0.2 bursts•(100 beats-1•mmHg-1, p=0.29. We conclude that tolerance to central hypovolemia is not related to either resting MSNA or sympathetic BRS.

  18. In-flight Assessment of Lower Body Negative Pressure as a Countermeasure for Post-flight Orthostatic Intolerance

    Science.gov (United States)

    Charles, J. B.; Stenger, M. B.; Phillips, T. R.; Arzeno, N. M.; Lee, S. M. C.

    2009-01-01

    Introduction. We investigated the efficacy of combining fluid loading with sustained lower body negative pressure (LBNP) to reverse orthostatic intolerance associated with weightlessness during and immediately after Space Shuttle missions. Methods. Shuttle astronauts (n=13) underwent 4 hours of LBNP at -30 mm(Hg) and ingested water and salt ( soak treatment) during flight in two complementary studies. In the first study (n=8), pre-flight heart rate (HR) and blood pressure (BP) responses to an LBNP ramp (5-min stages of -10 mm(Hg) steps to -50 mm(Hg) were compared to responses in-flight one and two days after LBNP soak treatment. In the second study (n=5), the soak was performed 24 hr before landing, and post-flight stand test results of soak subjects were compared with those of an untreated cohort (n=7). In both studies, the soak was scheduled late in the mission and was preceded by LBNP ramp tests at approximately 3-day intervals to document the in-flight loss of orthostatic tolerance. Results. Increased HR and decreased BP responses to LBNP were evident early in-flight. In-flight, one day after LBNP soak, HR and BP responses to LBNP were not different from pre-flight, but the effect was absent the second day after treatment. Post-flight there were no between-group differences in HR and BP responses to standing, but all 5 treatment subjects completed the 5-minute stand test whereas 2 of 7 untreated cohort subjects did not. Discussion. Exaggerated HR and BP responses to LBNP were evident within the first few days of space flight, extending results from Skylab. The combined LBNP and fluid ingestion countermeasure restored in-flight LBNP HR and BP responses to pre-flight levels and provided protection of post-landing orthostatic function. Unfortunately, any benefits of the combined countermeasure were offset by the complexity of its implementation, making it inappropriate for routine application during Shuttle flights.

  19. Treatment of hardware infection after osteosynthesis of lower leg using negative pressure wound therapy and transforming powder dressing.

    Science.gov (United States)

    Marinović, Marin; Ivandcić, Aldo; Spanjol, Josip; Pina, Maja; Bakota, Bore; Bandalović, Ante; Cukeljs, Fabijan

    2014-12-01

    Fractures of the distal part of the lower leg are more common in everyday practice and traumatology. In young and active patients these injuries are mainly caused by high energy trauma. They are treated with external fixator in first step, and in second step, after sanation of the soft tissue, with open reduction and internal fixation (ORIF). It is very safe and effective method of treatment. Treatment of the infections that occur in the early postoperative period after open reduction and internal fixation represents a great problem and challenge for surgeons. It is widely accepted that the presence of deep infection can't be cured in the presence of hardware. However, removal of hardware in the presence of unhealed fractures significantly complicates sanation of infection and fracture itself We have decided to present a 35-years-old patient with a hardware infection with present chronic wound with hardware exposed eight months after the first operation and six months after second operation. The wound measured one centimeter in diameter with cell detritus and bad granulations tissue inside the wound. Hardwre was exposed in the depth of the wound.The secretion was minimal. Negative Pressure Wound Therapy (NPWT) was applicated after debridemet and lavage performed in ambulatory conditions. The starting therapy was continuously -125 mm Hg of vacuum. After five days of NPWT the defect was partially filled with granula- tion tissue. For another five days we continue with NPWT with the same values of-125 mm Hg pressure but in the inter- mitent mode. After that period we used transforming powder dressing for covering and protection of the wound with was filled with granulation tissue. Five days later, wound was completely healed with epithelisation. After four months of patient follow-up, we found the wound is completely repaired. The patient denies pain and has continued orderly flow of fracture healing, with no signs of infection.

  20. Studies on pulsed hollow cathode capillary discharges

    Energy Technology Data Exchange (ETDEWEB)

    Choi, P; Dumitrescu-Zoita, C; Larour, J; Rous, J [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises; Favre, M; Moreno, J; Chuaqui, H; Wyndham, E [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Zambra, M [Comision Chilena de Energia Nuclear, Santiago (Chile); Wong, C S [Univ. of Malaya, Kuala Lumpur (Malaysia). Plasma Research Lab

    1997-12-31

    Preliminary results on radiation characteristics of pulsed hollow cathode capillary discharges are presented. The device combines the on axis electron beam assisted ionization capabilities of the transient hollow cathode discharge with a novel high voltage low inductance geometrical design, which integrates the local energy storage into the electrode system. A nanosecond regime high temperature plasma is produced in a long, high aspect ratio capillary, with light emission in the UV to XUV region. The discharge is operated from near vacuum to pressure in the 1000 mTorr range. (author). 2 figs., 7 refs.

  1. Role of different negative pressure values in the process of infected wounds treated by vacuum-assisted closure: an experimental study.

    Science.gov (United States)

    Zhou, Min; Yu, Aixi; Wu, Gang; Xia, Chengyan; Hu, Xiang; Qi, Baiwen

    2013-10-01

    Vacuum-assisted closure (VAC) device is widely used to treat infected wounds in clinical work. Although the effect of VAC with different negative pressure values is well established, whether different negative pressures could result in varying modulation of wound relative cytokines was not clear. We hypothesise that instead of the highest negative pressure value the suitable value for VAC is the one which is the most effective on regulating wound relative cytokines. Infected wounds created on pigs' back were used to investigate the effects of varying negative pressure values of VAC devices. Wounds were treated with VAC of different negative pressure values or moist gauze, which was set as control. The VAC foam, semiocclusive dresses and moist gauze were changed on days 3, 5, 7 and 9 after wounds were created. When changing dressings, tissues from wounds were harvested for bacteria count and histology examination including Masson's trichrome stain and immunohistochemistry for microvessels. Western blot was carried out to test the expression of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF). Results showed that on days 3 and 5 the number of bacteria in wounds treated by VAC with 75, 150, 225 and 300 mmHg was significantly decreased compared with that in wounds treated by gauze and 0 mmHg pressure value. However, there was no difference in wounds treated with negative pressure values of 75 , 150, 225 and 300 mmHg at any time spot. Immunohistochemistry showed that more microvessels were generated in wounds treated by VAC using 75 and 150 mmHg negative pressure comparing with that using 225 and 300 mmHg on days 3 and 5. However this difference vanished on days 7 and 9. Morphological evaluation by Masson's trichrome staining showed increased collagen deposition in VAC of 75 and 150 mmHg compared with that in VAC of 225 and 300 mmHg. Western blot showed that the expression of VEGF and bFGF significantly increased when the wounds

  2. Psychomotor performance during a 28 day head-down tilt with and without lower body negative pressure

    Science.gov (United States)

    Traon, A. Pavy-le; de Feneyrols, A. Rous; Cornac, A.; Abdeseelam, R.; N'uygen, D.; Lazerges, M.; Güell, A.; Bes, A.

    Several factors may affect psychomotor performance in space: sensory-motor changes, sleep disturbances, psychological modifications induced by the social isolation and confinement. However, psychomotor performance is difficult to assess. A battery of standardized and computerized tests, so-called "Automated Portable Test System" (APTS) was devised to ascertain the cognitive, perceptive and motor abilities and their possible fluctuations according to environmental effects. Antiorthostatic bedrest, often used to simulate weightlessness, (particularly cardiovascular modifications) also constitutes a situation of social confinement and isolation. During two bedrest experiments (with head-down tilt of -6°) of 28 days each, we intended to assess psychomotor performance of 6 males so as to determine whether: —on the one hand, it could be altered by remaining in decubitus; —on the other, the Lower Body Negative Pressure sessions, designed to prevent orthostatic intolerance back on Earth, could improve the performance. To accomplish this, part of the APTS tests as well as an automated perceptive attention test were performed. No downgrading of psychomotor performance was observed. On the contrary, the tasks were more accurately performed over time. In order to assess the experimental conditions on the acquisition phase, the learning curves were modelled. A beneficial effect of the LBNP sessions on simple tests involving the visual-motor coordination and attention faculties can only be regarded as a mere trend. Methods used in this experiment are also discussed.

  3. Negative pressure driven valence instability of Eu in cubic Eu0.4La0.6Pd3

    International Nuclear Information System (INIS)

    Pandey, Abhishek; Mazumdar, Chandan; Ranganathan, R

    2009-01-01

    We report the change in the valency of Eu-ions in the binary intermetallic cubic compound EuPd 3 induced by La doping at rare-earth sites. Doping of La generates negative chemical pressure in the lattice, resulting in a significant increase of the lattice parameter without altering the simple-cubic structure of the compound. Results of dc-magnetic measurements suggest that this increase in the lattice parameter is associated with the valence transition of Eu-ions from Eu 3+ to a mixed-valent state. As Eu 2+ -ions possess a large magnetic moment, this valence transition significantly modifies the magnetic behavior of the compound. In contrast to introducing boron at the vacant body center site of the unit cell to change the valency of Eu-ions, as in the case of EuPd 3 B, our results suggest it can also be altered by doping a rare-earth ion of larger size at the lattice site of Eu in EuPd 3 .

  4. Working in a danger zone: A qualitative study of Taiwanese nurses' work experiences in a negative pressure isolation ward.

    Science.gov (United States)

    Chen, Shu-Ling; Chen, Kuei-Ling; Lee, Li-Hung; Yang, Cheng-I

    2016-07-01

    Hospital nurses are frontline health care workers in controlling the spread of infectious diseases. It is not known if nurses working in negative pressure isolation wards (NPIWs) are better prepared than before to safely care for patients with common infectious diseases. For this qualitative descriptive study, 10 nurses were interviewed in depth about their experiences caring for patients in an NPIW. Tape recordings were transcribed verbatim and analyzed by qualitative content analysis. The following 5 themes were identified: (1) complexity of patient care, (2) dissatisfaction with the quantity and quality of protective equipment, (3) shortage of nursing staff, (4) continued worries about being infected, and (5) sensitivity to self-protection. Our participants' anxiety and uncertainty about being infected in the NPIW were increased by the complexity of patients' health problems and organizational factors. To protect themselves against infection before and during patient care, participants also developed sensitivity to, concepts about, and strategies to improve self-protection. NPIW administrators should pay more attention to nurses' concerns about improving the NPIW working environment, supply good quality protective equipment, and provide appropriate psychologic support and ongoing education to ensure that nurses feel safe while working. This ongoing education should refresh and update nurses' knowledge about disease transmission, therefore decreasing unnecessary anxiety based on misunderstandings about becoming infected. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Negative pressure wound therapy using polyvinyl alcohol foam to bolster full-thickness mesh skin grafts in dogs.

    Science.gov (United States)

    Or, Matan; Van Goethem, Bart; Kitshoff, Adriaan; Koenraadt, Annika; Schwarzkopf, Ilona; Bosmans, Tim; de Rooster, Hilde

    2017-04-01

    To report the use of negative pressure wound therapy (NPWT) with polyvinyl alcohol (PVA) foam to bolster full-thickness mesh skin grafts in dogs. Retrospective case series. Client-owned dogs (n = 8). Full-thickness mesh skin graft was directly covered with PVA foam. NPWT was maintained for 5 days (in 1 or 2 cycles). Grafts were evaluated on days 2, 5, 10, 15, and 30 for graft appearance and graft take, granulation tissue formation, and complications. Firm attachment of the graft to the recipient bed was accomplished in 7 dogs with granulation tissue quickly filling the mesh holes, and graft take considered excellent. One dog had bandage complications after cessation of the NPWT, causing partial graft loss. The PVA foam did not adhere to the graft or damage the surrounding skin. The application of NPWT with a PVA foam after full-thickness mesh skin grafting in dogs provides an effective method for securing skin grafts, with good graft acceptance. PVA foam can be used as a primary dressing for skin grafts, obviating the need for other interposing materials to protect the graft and the surrounding skin. © 2017 The American College of Veterinary Surgeons.

  6. Coverage of Deep Cutaneous Wounds Using Dermal Template in Combination with Negative-pressure Therapy and Subsequent Skin Graft

    Science.gov (United States)

    Chang, Alexandre A.; Lobato, Rodolfo C.; Nakamoto, Hugo A.; Tuma, Paulo; Ferreira, Marcus C.

    2014-01-01

    Background: We consider the use of dermal matrix associated with a skin graft to cover deep wounds in the extremities when tendon and bone are exposed. The objective of this article was to evaluate the efficacy of covering acute deep wounds through the use of a dermal regeneration template (Integra) associated with vacuum therapy and subsequent skin grafting. Methods: Twenty patients were evaluated prospectively. All of them had acute (up to 3 weeks) deep wounds in the limbs. We consider a deep wound to be that with exposure of bone, tendon, or joint. Results: The average area of integration of the dermal regeneration template was 86.5%. There was complete integration of the skin graft over the dermal matrix in 14 patients (70%), partial integration in 5 patients (25%), and total loss in 1 case (5%). The wound has completely closed in 95% of patients. Conclusions: The use of Integra dermal template associated with negative-pressure therapy and skin grafting showed an adequate rate of resolution of deep wounds with low morbidity. PMID:25289363

  7. Negative Pressure Wound Therapy Applied Before and After Split-Thickness Skin Graft Helps Healing of Fournier Gangrene

    Science.gov (United States)

    Ye, Junna; Xie, Ting; Wu, Minjie; Ni, Pengwen; Lu, Shuliang

    2015-01-01

    Abstract Fournier gangrene is a rare but highly infectious disease characterized by fulminant necrotizing fasciitis involving the genital and perineal regions. Negative pressure wound therapy (NPWT; KCI USA Inc, San Antonio, TX) is a widely adopted technique in many clinical settings. Nevertheless, its application and effect in the treatment of Fournier gangrene are unclear. A 47-year-old male patient was admitted with an anal abscess followed by a spread of the infection to the scrotum, which was caused by Pseudomonas aeruginosa. NPWT was applied on the surface of the scrotal area and continued for 10 days. A split-thickness skin graft from the scalp was then grafted to the wound, after which, NPWT utilizing gauze sealed with an occlusive dressing and connected to a wall suction was employed for 7 days to secure the skin graft. At discharge, the percentage of the grafted skin alive on the scrotum was 98%. The wound beside the anus had decreased to 4 × 0.5 cm with a depth of 1 cm. Follow-up at the clinic 1 month later showed that both wounds had healed. The patient did not complain of any pain or bleeding, and was satisfied with the outcome. NPWT before and after split-thickness skin grafts is safe, well tolerated, and efficacious in the treatment of Fournier gangrene. PMID:25654376

  8. Anomalous thermal expansion, negative linear compressibility, and high-pressure phase transition in ZnAu2(CN) 4 : Neutron inelastic scattering and lattice dynamics studies

    Science.gov (United States)

    Gupta, Mayanak K.; Singh, Baltej; Mittal, Ranjan; Zbiri, Mohamed; Cairns, Andrew B.; Goodwin, Andrew L.; Schober, Helmut; Chaplot, Samrath L.

    2017-12-01

    We present temperature-dependent inelastic-neutron-scattering measurements, accompanied by ab initio calculations of the phonon spectra and elastic properties as a function of pressure to quantitatively explain an unusual combination of negative thermal expansion and negative linear compressibility behavior of ZnAu2(CN) 4 . The mechanism of the negative thermal expansion is identified in terms of specific anharmonic phonon modes that involve bending of the -Zn-NC-Au-CN-Zn- linkage. The soft phonon at the L point at the Brillouin zone boundary quantitatively relates to the high-pressure phase transition at about 2 GPa. The ambient pressure structure is also found to be close to an elastic instability that leads to a weakly first-order transition.

  9. Use of negative-pressure dressings and split-thickness skin grafts following penile shaft reduction and reduction scrotoplasty in the management of penoscrotal elephantiasis.

    Science.gov (United States)

    Stokes, Tracey H; Follmar, Keith E; Silverstein, Ari D; Weizer, Alon Z; Donatucci, Craig F; Anderson, Everett E; Erdmann, Detlev

    2006-06-01

    From 1988 to 2005, 8 men who presented with penoscrotal elephantiasis underwent penile shaft degloving and reduction scrotoplasty, followed by transplantation of a split-thickness skin graft (STSG) to the penile shaft. The etiology of elephantiasis in these patients included self-injection of viscous fluid and postsurgical obstructive lymphedema. In the 6 most recent cases, negative-pressure dressings were applied over the STSG to promote graft take, and STSG take rate was 100%. The results of our series corroborate those of a previous report, which showed circumferential negative-pressure dressings to be safe and efficacious in bolstering STSGs to the penile shaft. Furthermore, these results suggest that the use of negative-pressure dressings may improve graft take in this patient population.

  10. Isotherms of Capillary Condensation Influenced by Formation of Adsorption Films.

    Science.gov (United States)

    Churaev; Starke; Adolphs

    2000-01-15

    Isotherms of capillary condensation are often used to determine the vapor sorption capacity of porous adsorbents as well as the pore size distribution by radii. In this paper, for calculating the volume of capillary condensate and of adsorption films in a porous body, an approach based on the theory of surface forces is used. Adsorption isotherms and disjoining pressure isotherms of wetting films are presented here in an exponential form discussed earlier. The calculations were made for straight cylindrical capillaries of different radii and slit pores of different width. The mechanisms of capillary condensation differ in cylindrical and slit pores. In cylindrical pores capillary condensation occurs due to capillary instability of curved wetting films on a capillary surface, when film thickness grows. In the case of slit pores, coalescence of wetting films formed on opposite slit surfaces proceeds under the action of attractive dispersion forces. Partial volumes of liquid in the state of both capillary condensate and adsorbed films are calculated dependent on the relative vapor pressure in a surrounding media. Copyright 2000 Academic Press.

  11. How bacterial cell division might cheat turgor pressure - a unified mechanism of septal division in Gram-positive and Gram-negative bacteria.

    Science.gov (United States)

    Erickson, Harold P

    2017-08-01

    An important question for bacterial cell division is how the invaginating septum can overcome the turgor force generated by the high osmolarity of the cytoplasm. I suggest that it may not need to. Several studies in Gram-negative bacteria have shown that the periplasm is isoosmolar with the cytoplasm. Indirect evidence suggests that this is also true for Gram-positive bacteria. In this case the invagination of the septum takes place within the uniformly high osmotic pressure environment, and does not have to fight turgor pressure. A related question is how the V-shaped constriction of Gram-negative bacteria relates to the plate-like septum of Gram-positive bacteria. I collected evidence that Gram-negative bacteria have a latent capability of forming plate-like septa, and present a model in which septal division is the basic mechanism in both Gram-positive and Gram-negative bacteria. © 2017 WILEY Periodicals, Inc.

  12. Micro-injector for capillary electrophoresis.

    Science.gov (United States)

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Negative pressure wound therapy via vacuum-assisted closure following partial foot amputation: what is the role of wound chronicity?

    Science.gov (United States)

    Armstrong, David G; Lavery, Lawrence A; Boulton, Andrew J M

    2007-03-01

    Randomised clinical trials (RCTs) to evaluate diabetic foot wound therapies have systematically eliminated large acute wounds from evaluation, focusing only on smaller chronic wounds. The purpose of this study was to evaluate the proportion and rate of wound healing in acute and chronic wounds after partial foot amputation in individuals with diabetes treated with negative pressure wound therapy (NPWT) delivered by the vacuum-assisted closure (VAC) device or with standard wound therapy (SWT). This study constitutes a secondary analysis of patients enrolled in a 16-week RCT of NPWT: 162 open foot amputation wounds (mean wound size = 20.7 cm(2)) were included. Acute wounds were defined as the wounds less than 30 days after amputation, whereas chronic wounds as the wounds greater than 30 days. Inclusion criteria consisted of individuals older than 18 years, presence of a diabetic foot amputation wound up to the transmetatarsal level and adequate perfusion. Wound size and healing were confirmed by independent, blinded wound evaluators. Analyses were done on an intent-to-treat basis. There was a significantly higher proportion of acute wounds (SWT = 59; NPWT = 63) than chronic wounds (SWT = 26; NPWT = 14), evaluated in this clinical trial (P = 0.001). There was no significant difference in the proportion of acute and chronic wounds achieving complete wound closure in either treatment group. Despite this finding, the Kaplan-Meier curves demonstrated statistically significantly faster healing in the NPWT group in both acute (P = 0.030) and chronic wounds (P = 0.033). Among the patients treated with NPWT via the VAC, there was not a significant difference in healing as a function of chronicity. In both the acute and the chronic wound groups, results for patients treated with NPWT were superior to those for the patients treated with SWT. These results appear to indicate that wound duration should not deter the clinician from using this modality to treat complex wounds.

  14. Negative pressure wound therapy in the management of late deep infections after open reconstruction of achilles tendon rupture.

    Science.gov (United States)

    Mosser, Philipp; Kelm, Jens; Anagnostakos, Konstantinos

    2015-01-01

    Infection is a major complication after open reconstruction of Achilles tendon ruptures. We report on the use of vacuum-assisted closure (VAC) therapy in the treatment of late deep infections after open Achilles tendon reconstruction. Six patients (5 males [83.33%], 1 female [16.67%]; mean age, 52.8 [range 37 to 66] years) were been treated using an identical protocol. Surgical management consisted of debridement, lavage, and necrectomy of infected tendon parts. The VAC therapy was used for local wound preconditioning and infection management. A continuous negative pressure of 125 mm Hg was applied on each wound. For final wound closure, a split-thickness skin graft was performed. The skin graft healing process was also supported by VAC therapy during the first 5 days. The VAC dressings were changed a mean average of 3 (range 1 to 4) times until split-thickness skin grafting could be performed. The mean total duration of the VAC therapy was 13.6 ± 5.9 days. The mean hospital stay was 31.2 ± 15.9 days. No complications with regard to bleeding, seroma, or hematoma formation beneath the skin graft were observed. At a mean follow-up duration of 29.9 (range 4 to 65) months, no re-infection or infection persistence was observed. The VAC device seems to be a valuable tool in the treatment of infected tendons. The generalization of these conclusions should await the results of future studies with larger patient series. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Gas-Filled Capillary Model

    International Nuclear Information System (INIS)

    Steinhauer, L. C.; Kimura, W. D.

    2006-01-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment

  16. Colloid mobilization and transport during capillary fringe fluctuations.

    Science.gov (United States)

    Aramrak, Surachet; Flury, Markus; Harsh, James B; Zollars, Richard L

    2014-07-01

    Capillary fringe fluctuations due to changing water tables lead to displacement of air-water interfaces in soils and sediments. These moving air-water interfaces can mobilize colloids. We visualized colloids interacting with moving air-water interfaces during capillary fringe fluctuations by confocal microscopy. We simulated capillary fringe fluctuations in a glass-bead-filled column. We studied four specific conditions: (1) colloids suspended in the aqueous phase, (2) colloids attached to the glass beads in an initially wet porous medium, (3) colloids attached to the glass beads in an initially dry porous medium, and (4) colloids suspended in the aqueous phase with the presence of a static air bubble. Confocal images confirmed that the capillary fringe fluctuations affect colloid transport behavior. Hydrophilic negatively charged colloids initially suspended in the aqueous phase were deposited at the solid-water interface after a drainage passage, but then were removed by subsequent capillary fringe fluctuations. The colloids that were initially attached to the wet or dry glass bead surface were detached by moving air-water interfaces in the capillary fringe. Hydrophilic negatively charged colloids did not attach to static air-bubbles, but hydrophobic negatively charged and hydrophilic positively charged colloids did. Our results demonstrate that capillary fringe fluctuations are an effective means for colloid mobilization.

  17. Biomimetic Unidirectional Capillary Action

    Science.gov (United States)

    Rupert, Eric; Moran, Patrick; Dahl, Jason

    2017-11-01

    In arid environments animals require specialized adaptations to collect adequate water. The Texas horned lizard (P. cornutum) has superhydrophylic skin which draws water out of moist soil or directly from water sources. The water then makes its way into the lizard's unidirectional capillary system, made of overlapping scales, which serves to channel water to its mouth. Testing different channel geometries, repeated ``D'' shaped chambers as in Commans et al. (2015) and truncated isosceles triangle chambers, as found in P. cornutum, we show the ability to have passive, unidirectional, fluid transport. Tests were carried out with the capillaries in a horizontal configuration. While both capillary geometries produced the desired traits, the triangular chambers showed superior unidirectionality, with no observed back flow, while ``D'' chambers showed back flow under testing conditions. The chambers provided similar flow rates. These types of channel systems will find use in microfluidics, notably in medical, printing, and lab-on-chip applications.

  18. Capillary condenser/evaporator

    Science.gov (United States)

    Valenzuela, Javier A. (Inventor)

    2010-01-01

    A heat transfer device is disclosed for transferring heat to or from a fluid that is undergoing a phase change. The heat transfer device includes a liquid-vapor manifold in fluid communication with a capillary structure thermally connected to a heat transfer interface, all of which are disposed in a housing to contain the vapor. The liquid-vapor manifold transports liquid in a first direction and conducts vapor in a second, opposite direction. The manifold provides a distributed supply of fluid (vapor or liquid) over the surface of the capillary structure. In one embodiment, the manifold has a fractal structure including one or more layers, each layer having one or more conduits for transporting liquid and one or more openings for conducting vapor. Adjacent layers have an increasing number of openings with decreasing area, and an increasing number of conduits with decreasing cross-sectional area, moving in a direction toward the capillary structure.

  19. A compare between myocardial topical negative pressure levels of -25 mmHg and -50 mmHg in a porcine model

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Paulsson, Per; Mokhtari, Arash

    2008-01-01

    Topical negative pressure (TNP), widely used in wound therapy, is known to stimulate wound edge blood flow, granulation tissue formation, angiogenesis, and revascularization. We have previously shown that application of a TNP of -50 mmHg to the myocardium significantly increases microvascular blo...

  20. Major bleeding during negative pressure wound/V.A.C.®--therapy for postsurgical deep sternal wound infection--a critical appraisal

    NARCIS (Netherlands)

    van Wingerden, Jan J.; Segers, Patrique; Jekel, Lilian

    2011-01-01

    Negative-pressure wound therapy, commercially known as vacuum-assisted closure (V.A.C.®) therapy, has become one of the most popular (and efficacious) interim (prior to flap reconstruction) or definite methods of managing deep sternal wound infection. Complications such as profuse bleeding, which

  1. Negative pressure of the environmental air in the cleaning area of the materials and sterilization center: a systematic review.

    Science.gov (United States)

    Ciofi-Silva, Caroline Lopes; Hansen, Lisbeth Lima; Almeida, Alda Graciele Claudio Dos Santos; Kawagoe, Julia Yaeko; Padoveze, Maria Clara; Graziano, Kazuko Uchikawa

    2016-09-01

    to analyze the scientific evidence on aerosols generated during cleaning activities of health products in the Central Service Department (CSD) and the impact of the negative pressure of the ambient air in the cleaning area to control the dispersion of aerosols to adjacent areas. for this literature systematic review the following searches were done: search guidelines, manuals or national and international technical standards given by experts; search in the portal and databases PubMed, Scopus, CINAHL and Web of Science; and a manual search of scientific articles. the five technical documents reviewed recommend that the CSD cleaning area should have a negative differential ambient air pressure, but scientific articles on the impact of this intervention were not found. The four articles included talked about aerosols formed after the use of a ultrasonic cleaner (an increased in the contamination especially during use) and pressurized water jet (formation of smaller aerosols 5μm). In a study, the aerosols formed from contaminated the hot tap water with Legionella pneumophila were evaluated. there is evidence of aerosol formation during cleanup activities in CSD. Studies on occupational diseases of respiratory origin of workers who work in CSD should be performed. analisar as evidências científicas sobre aerossóis gerados durante atividades de limpeza dos produtos para saúde no Centro de Material e Esterilização (CME) e o impacto da pressão negativa do ar ambiente na área de limpeza para controle da dispersão de aerossóis para áreas adjacentes. para essa revisão sistemática de literatura foram realizadas: busca de diretrizes, manuais ou normas técnicas nacionais e internacionais indicadas por especialistas; busca no portal e bases de dados PUBMED, SCOPUS, Cinahl e Web of Science; e busca manual de artigos científicos. Os cinco documentos técnicos analisados preconizam que na área de limpeza do CME haja diferencial negativo de pressão do ar ambiente

  2. Pressure Effect on Entrance Flow

    DEFF Research Database (Denmark)

    Christensen, Jens Horslund; Couch, Mark

    1997-01-01

    The paper reports on experimentally determined pressure drops associated with orifice and capillary dies, where the exit pressure is elevated. The effect of hydrostatic pressure up to 70 MPa is reported for PS, LDPE and PP melts.......The paper reports on experimentally determined pressure drops associated with orifice and capillary dies, where the exit pressure is elevated. The effect of hydrostatic pressure up to 70 MPa is reported for PS, LDPE and PP melts....

  3. Economic and organizational sustainability of a negative-pressure portable device for the prevention of surgical-site complications

    Directory of Open Access Journals (Sweden)

    Foglia E

    2017-06-01

    Full Text Available Emanuela Foglia,1 Lucrezia Ferrario,1 Elisabetta Garagiola,1 Giuseppe Signoriello,2 Gianluca Pellino,3 Davide Croce,1,4 Silvestro Canonico3 1Centre for Health Economics, Social and Health Care Management - LIUC University, Castellanza, Italy; 2Department of Mental Health and Preventive Medicine, University of Campania “Luigi Vanvitelli”, Naples, Italy; 3School of Medicine, University of Campania “Luigi Vanvitelli”, Naples, Italy; 4School of Public Health, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South \tAfrica Purpose: Surgical-site complications (SSCs affect patients’ clinical pathway, prolonging their hospitalization and incrementing their management costs. The present study aimed to assess the economic and organizational implications of a portable device for negative-pressure wound therapy (NPWT implementation, compared with the administration of pharmacological therapies alone for preventing surgical complications in patients undergoing general, cardiac, obstetrical–gynecological, or orthopedic surgical procedures.Patients and methods: A total of 8,566 hospital procedures, related to the year 2015 from one hospital, were evaluated considering infection risk index, occurrence rates of SSCs, drug therapies, and surgical, diagnostic, and specialist procedures and hematological exams. Activity-based costing and budget impact analyses were implemented for the economic assessment.Results: Patients developing an SSC absorbed i 64.27% more economic resources considering the length of stay (€ 8,269±2,096 versus € 5,034±2,901, p<0.05 and ii 42.43% more economic resources related to hematological and diagnostic procedures (€ 639±117 versus € 449±72, p<0.05. If the innovative device had been used over the 12-month time period, it would have decreased the risk of developing SSCs; the hospital would have realized an average reduction in health care expenditure equal to −0.69% (−€ 483

  4. [Can Topical Negative Pressure Therapy be Performed as a Cost-Effective General Surgery Procedure in the German DRG System?].

    Science.gov (United States)

    Hirche, Z; Xiong, L; Hirche, C; Willis, S

    2016-04-01

    Topical negative pressure therapy (TNPT) has been established for surgical wound therapy with different indications. Nevertheless, there is only sparse evidence regarding its therapeutic superiority or cost-effectiveness in the German DRG system (G-DRG). This study was designed to analyse the cost-effectiveness of TNPT in the G-DRG system with a focus on daily treatment costs and reimbursement in a general surgery care setting. In this retrospective study, we included 176 patients, who underwent TNPT between 2007 and 2011 for general surgery indications. Analysis of the cost-effectiveness involved 149 patients who underwent a simulation to calculate the reimbursement with or without TNPT by a virtual control group in which the TNP procedure was withdrawn for DRG calculation. This was followed by a calculation of costs for wound dressings and TNPT rent and material costs. Comparison between the "true" and the virtual group enabled calculation of the effective remaining surplus per case. Total reimbursement by included TNPT cases was 2,323 ,70.04 €. Costs for wound dressings and TNPT rent were 102,669.20 €. In 41 cases there was a cost-effectiveness (27.5%) with 607,422.03 € with TNP treatment, while the control group without TNP generated revenues of 442,015.10 €. Costs for wound dressings and TNPT rent were 47,376.68 €. In the final account we could generate a cost-effectiveness of 6759 € in 5 years per 149 patients by TNPT. In 108 cases there was no cost-effectiveness (72.5%). TNPT applied in a representative general surgery setting allows for wound therapy without a major financial burden. Based on the costs for wound dressings and TNPT rent, a primarily medically based decision when to use TNPT can be performed in a balanced product cost accounting. This study does not analyse the superiority of TNPT in wound care, so further prospective studies are required which focus on therapeutic superiority and cost-effectiveness. Georg Thieme

  5. Effects of negative pressure wound therapy on the expression of EDA+ FN in granulation tissues of human diabetic foot wounds

    Directory of Open Access Journals (Sweden)

    Shao-ling YANG

    2017-04-01

    Full Text Available Objective  To investigate the effects of negative pressure wound therapy (NPWT on the expression of EDA+ FN in granulation tissues of human diabetic foot wounds. Methods  Forty patients with diabetic foot wounds fitting the inclusion criteria, admitted from Jan. 2014 to Jun. 2016, were randomly and equally apportioned to receive either NPWT or conventional gauze therapy (control for 14 days. Granulated tissue biopsies were collected before (0 day and after (14 day treatment in both groups. All biopsies were subdivided into two parts. One part was preserved in 4% paraformaldehyde for immunocytochemical staining of EDA+ FN, and the other part was stored at –80℃for Western blotting and PCR analysis of EDA+ FN. Results  The immunohistochemical analysis revealed that the mean area density of EDA+ FN increased in both NPWT group and control group at day 14 relative to day 0, but the change value of mean area density was higher in NPWT group than in control group (P<0.01. Western blotting showed that the relative protein levels of EDA+ FN increased in both NPWT group and control group at day 14 relative to day 0, but the change value of relative protein levels of EDA+ FN was higher in NPWT group than in control group (P<0.01. The real time PCR analysis demonstrated that the relative mRNA levels of EDA+ FN increased in both NPWT group and control group at day 14 relative to day 0, but the change value of relative mRNA levels of EDA+ FN was higher in NPWT group than in control group (P<0.01. The results demonstrated the higher protein and mRNA levels of EDA+ FN in NPWT group than that in control group. Conclusion  NPWT obviously enhances EDA+ FN expression in granulation tissue of diabetic foot wound, as a result promotes wound healing. DOI: 10.11855/j.issn.0577-7402.2017.03.09

  6. Western Blotting using Capillary Electrophoresis

    OpenAIRE

    Anderson, Gwendolyn J.; Cipolla, Cynthia; Kennedy, Robert T.

    2011-01-01

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein a...

  7. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  8. Early Regimes of Water Capillary Flow in Slit Silica Nanochannels

    DEFF Research Database (Denmark)

    Oyarzua, Elton; Walther, Jens Honore; Mejia, Andres

    2015-01-01

    on the dynamics of capillaryfilling. The results indicate that the nanoscale imbibition process is divided into three main flow regimes:an initial regime where the capillary force is balanced only by the inertial drag and characterized by aconstant velocity and a plug flow profile. In this regime, the meniscus...... velocity profiles identify the passage froman inviscid flow to a developing Poiseuille flow. Gas density profiles ahead of the capillary front indicatea transient accumulation of air on the advancing meniscus. Furthermore, slower capillary filling ratescomputed for higher air pressures reveal a significant...... retarding effect of the gas displaced by the advancing meniscus....

  9. Revascularization and periapical repair after endodontic treatment using apical negative pressure irrigation versus conventional irrigation plus triantibiotic intracanal dressing in dogs' teeth with apical periodontitis.

    Science.gov (United States)

    da Silva, Lea Assed Bezerra; Nelson-Filho, Paulo; da Silva, Raquel Assed Bezerra; Flores, Daniel Silva Herzog; Heilborn, Carlos; Johnson, James D; Cohenca, Nestor

    2010-05-01

    The objective of this study was to evaluate in vivo the revascularization and the apical and periapical repair after endodontic treatment using 2 techniques for root canal disinfection (apical negative pressure irrigation versus apical positive pressure irrigation plus triantibiotic intracanal dressing) in immature dogs' teeth with apical periodontitis. Two test groups of canals with experimentally induced apical periodontitis were evaluated according to the disinfection technique: Group 1, apical negative pressure irrigation (EndoVac system), and Group 2, apical positive pressure irrigation (conventional irrigation) plus triantibiotic intracanal dressing. In Group 3 (positive control), periapical lesions were induced, but no endodontic treatment was done. Group 4 (negative control) was composed of sound teeth. The animals were killed after 90 days and the maxillas and mandibles were subjected to histological processing. The sections were stained with hematoxylin and eosin and Mallory Trichrome and examined under light microscopy. A description of the apical and periapical features was done and scores were attributed to the following histopathological parameters: newly formed mineralized apical tissue, periapical inflammatory infiltrate, apical periodontal ligament thickness, dentin resorption, and bone tissue resorption. Intergroup comparisons were done by the Kruskal-Wallis and Dunn's tests (alpha = 0.05). Although statistically significant difference was found only for the inflammatory infiltrate (P irrigation with the EndoVac system can be considered as a promising disinfection protocol in immature teeth with apical periodontitis, suggesting that the use of intracanal antibiotics might not be necessary. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  10. Cracked rocks with positive and negative Poisson's ratio: real-crack properties extracted from pressure dependence of elastic-wave velocities

    Science.gov (United States)

    Zaitsev, Vladimir Y.; Radostin, Andrey V.; Dyskin, Arcady V.; Pasternak, Elena

    2017-04-01

    We report results of analysis of literature data on P- and S-wave velocities of rocks subjected to variable hydrostatic pressure. Out of about 90 examined samples, in more than 40% of the samples the reconstructed Poisson's ratios are negative for lowest confining pressure with gradual transition to the conventional positive values at higher pressure. The portion of rocks exhibiting negative Poisson's ratio appeared to be unexpectedly high. To understand the mechanism of negative Poisson's ratio, pressure dependences of P- and S-wave velocities were analyzed using the effective medium model in which the reduction in the elastic moduli due to cracks is described in terms of compliances with respect to shear and normal loading that are imparted to the rock by the presence of cracks. This is in contrast to widely used descriptions of effective cracked medium based on a specific crack model (e.g., penny-shape crack) in which the ratio between normal and shear compliances of such a crack is strictly predetermined. The analysis of pressure-dependences of the elastic wave velocities makes it possible to reveal the ratio between pure normal and shear compliances (called q-ratio below) for real defects and quantify their integral content in the rock. The examination performed demonstrates that a significant portion (over 50%) of cracks exhibit q-ratio several times higher than that assumed for the conventional penny-shape cracks. This leads to faster reduction of the Poisson's ratio with increasing the crack concentration. Samples with negative Poisson's ratio are characterized by elevated q-ratio and simultaneously crack concentration. Our results clearly indicate that the traditional crack model is not adequate for a significant portion of rocks and that the interaction between the opposite crack faces leading to domination of the normal compliance and reduced shear displacement discontinuity can play an important role in the mechanical behavior of rocks.

  11. A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions

    Science.gov (United States)

    Thomas, Evan A.; Graf, John C.; Weislogel, Mark M.

    2010-01-01

    draining the bulk fluid in a continuous circuit. The functional operation of the SPS involves introducing liquid flow (from a human body, a syringe, or other source) to the two-phase inlet while an air fan pulls on the air exit lines. The fan is operated until the liquid is fully introduced. The system is drained by negative pressure on the liquid drain lines when the SPS containment system is full.

  12. Practical capillary electrophoresis

    CERN Document Server

    Weinberger, Robert

    2000-01-01

    In the 1980s, capillary electrophoresis (CE) joined high-performance liquid chromatography (HPLC) as the most powerful separation technique available to analytical chemists and biochemists. Published research using CE grew from 48 papers in the year of commercial introduction (1988) to 1200 in 1997. While only a dozen major pharmaceutical and biotech companies have reduced CE to routine practice, the applications market is showing real or potential growth in key areas, particularly in the DNA marketplace for genomic mapping and forensic identification. For drug development involving small molecules (including chiral separations), one CE instrument can replace 10 liquid chromatographs in terms of speed of analysis. CE also uses aqueous rather than organic solvents and is thus environmentally friendlier than HPLC. The second edition of Practical Capillary Electrophoresis has been extensively reorganized and rewritten to reflect modern usage in the field, with an emphasis on commercially available apparatus and ...

  13. Major bleeding during negative pressure wound/V.A.C.® - therapy for postsurgical deep sternal wound infection - a critical appraisal

    Directory of Open Access Journals (Sweden)

    Segers Patrique

    2011-09-01

    Full Text Available Abstract Negative-pressure wound therapy, commercially known as vacuum-assisted closure (V.A.C.® therapy, has become one of the most popular (and efficacious interim (prior to flap reconstruction or definite methods of managing deep sternal wound infection. Complications such as profuse bleeding, which may occur during negative-pressure therapy but not necessarily due to it, are often attributed to a single factor and reported as such. However, despite the wealth of clinical experience internationally available, information regarding certain simple considerations is still lacking. Garnering information on all the factors that could possibly influence the outcome has become more difficult due to a (fortunate decrease in the incidence of deep sternal wound infection. If more insight is to be gained from fewer clinical cases, then various potentially confounding factors should be fully disclosed before complications can be attributed to the technique itself or improvements to negative-pressure wound therapy for deep sternal wound infection can be accepted as evidence-based and the guidelines for its use adapted. The authors propose the adoption of a simple checklist in such cases.

  14. Effect of negative pressure therapy on repair of soft tissues of the lower extremities in patients with neuropathic and neuroischaemic forms of diabetic foot syndrome

    Directory of Open Access Journals (Sweden)

    Ekaterina Leonidovna Zaytseva

    2014-06-01

    Full Text Available Aim. To evaluate the efficiency of topical negative pressure wound therapy (NPWT compared with standard therapy for the regeneration of the soft tissues of the lower extremities in patients with diabetic foot syndrome. Materials and Methods. The effects of negative pressure therapy on the clinical (size, tissue oxygenation, histological (light microscopy and immunohistochemical (CD68, MMP-9, TIMP-1 aspects of repair of the soft tissue of the lower extremities in patients with diabetes mellitus were compared with those of standard treatment. Thirty-one patients with diabetic foot ulcers were included in the study from the moment of debridement until the plastic closure of the wound. During the perioperative period, 13 patients received NPWT (-90 to -120 mmHg and 18 patients received standard therapy. Results. A reduction of the wound area (26.6%?17.2% and the depth of the defects (40.5%?25.6% were achieved with negative pressure therapy compared with baseline data. In the control group, the corresponding values were 25.3%?19.4% and 21.8%?21.6%, respectively. The results of transcutaneous oximetry showed a greater increase in the level of local hemodynamics in the study group (p

  15. Modulation of capillary condensation by trace component

    Directory of Open Access Journals (Sweden)

    Shiqi Zhou

    2011-06-01

    Full Text Available Impact of trace component on capillary condensation (CC is investigated systematically using a classical density functional theory. It is discovered that (i presence of the trace component makes the CC to occur at much lower condensation pressure than when its absence; (ii Lennard-Jones potential parameters like size parameter and energy parameter of the trace component, and its concentration in the bulk adsorption system, show their effects the most remarkably within a particular range beyond which the effects eventually become insignificant. The present discoveries have implications in low pressure storage of gases, separation and enrichment of low concentration component, and easy control of CC transition, etc.

  16. Stability of the geometrically frustrated magnetic state of Ca3CoRhO6 to applications of positive and negative pressure

    International Nuclear Information System (INIS)

    Mohapatra, Niharika; Iyer, Kartik K; Jammalamadaka, S Narayana; Sampathkumaran, E V; Rayaprol, Sudhindra

    2008-01-01

    The influence of negative chemical pressure induced by gradual replacement of Ca by Sr as well as of external pressure (up to 10 kbar) on the magnetism of Ca 3 CoRhO 6 has been investigated by magnetization studies. It is found that the solid solution, Ca 3-x Sr x CoRhO 6 , exists at least until about x = 1.0 without any change in the crystal structure. Apart from insensitivity of the spin-chain feature to volume expansion, the characteristic features of geometrical frustration interestingly appear at the same temperatures for all compositions, in sharp contrast to the response to Y substitution for Ca (reported previously). Interestingly, the huge frequency dependence of ac susceptibility known for the parent compound persists for all compositions. We do not find a change in the properties under external pressure. The stability of the magnetic anomalies of this compound to volume change (about 4%) is puzzling

  17. Robust high pressure stability and negative thermal expansion in sodium-rich antiperovskites Na{sub 3}OBr and Na{sub 4}OI{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yonggang, E-mail: yyggwang@gmail.com, E-mail: yangwg@hpstar.ac.cn, E-mail: yusheng.zhao@unlv.edu [High Pressure Science and Engineering Center, University of Nevada, Las Vegas, Nevada 89154 (United States); Institute of Nanostructured Functional Materials, Huanghe Science and Technology College, Zhengzhou, Henan 450006 (China); High Pressure Synergetic Consortium (HPSynC), Geophysical Laboratory, Carnegie Institution of Washington, Argonne, Illinois 60439 (United States); Wen, Ting [Institute of Nanostructured Functional Materials, Huanghe Science and Technology College, Zhengzhou, Henan 450006 (China); Park, Changyong; Kenney-Benson, Curtis [High Pressure Collaborative Access Team (HPCAT), Geophysical Laboratory, Carnegie Institution of Washington, Argonne, Illinois 60439 (United States); Pravica, Michael; Zhao, Yusheng, E-mail: yyggwang@gmail.com, E-mail: yangwg@hpstar.ac.cn, E-mail: yusheng.zhao@unlv.edu [High Pressure Science and Engineering Center, University of Nevada, Las Vegas, Nevada 89154 (United States); Yang, Wenge, E-mail: yyggwang@gmail.com, E-mail: yangwg@hpstar.ac.cn, E-mail: yusheng.zhao@unlv.edu [High Pressure Synergetic Consortium (HPSynC), Geophysical Laboratory, Carnegie Institution of Washington, Argonne, Illinois 60439 (United States); Center for High Pressure Science and Technology Advanced Research (HPSTAR), Shanghai 201203 (China)

    2016-01-14

    The structure stability under high pressure and thermal expansion behavior of Na{sub 3}OBr and Na{sub 4}OI{sub 2}, two prototypes of alkali-metal-rich antiperovskites, were investigated by in situ synchrotron X-ray diffraction techniques under high pressure and low temperature. Both are soft materials with bulk modulus of 58.6 GPa and 52.0 GPa for Na{sub 3}OBr and Na{sub 4}OI{sub 2}, respectively. The cubic Na{sub 3}OBr structure and tetragonal Na{sub 4}OI{sub 2} with intergrowth K{sub 2}NiF{sub 4} structure are stable under high pressure up to 23 GPa. Although being a characteristic layered structure, Na{sub 4}OI{sub 2} exhibits nearly isotropic compressibility. Negative thermal expansion was observed at low temperature range (20–80 K) in both transition-metal-free antiperovskites for the first time. The robust high pressure structure stability was examined and confirmed by first-principles calculations among various possible polymorphisms qualitatively. The results provide in-depth understanding of the negative thermal expansion and robust crystal structure stability of these antiperovskite systems and their potential applications.

  18. Robust high pressure stability and negative thermal expansion in sodium-rich antiperovskites Na3OBr and Na4OI2

    International Nuclear Information System (INIS)

    Wang, Yonggang; Wen, Ting; Park, Changyong; Kenney-Benson, Curtis; Pravica, Michael; Zhao, Yusheng; Yang, Wenge

    2016-01-01

    The structure stability under high pressure and thermal expansion behavior of Na 3 OBr and Na 4 OI 2 , two prototypes of alkali-metal-rich antiperovskites, were investigated by in situ synchrotron X-ray diffraction techniques under high pressure and low temperature. Both are soft materials with bulk modulus of 58.6 GPa and 52.0 GPa for Na 3 OBr and Na 4 OI 2 , respectively. The cubic Na 3 OBr structure and tetragonal Na 4 OI 2 with intergrowth K 2 NiF 4 structure are stable under high pressure up to 23 GPa. Although being a characteristic layered structure, Na 4 OI 2 exhibits nearly isotropic compressibility. Negative thermal expansion was observed at low temperature range (20–80 K) in both transition-metal-free antiperovskites for the first time. The robust high pressure structure stability was examined and confirmed by first-principles calculations among various possible polymorphisms qualitatively. The results provide in-depth understanding of the negative thermal expansion and robust crystal structure stability of these antiperovskite systems and their potential applications

  19. A Risk Analysis Methodology to Address Human and Organizational Factors in Offshore Drilling Safety: With an Emphasis on Negative Pressure Test

    Science.gov (United States)

    Tabibzadeh, Maryam

    According to the final Presidential National Commission report on the BP Deepwater Horizon (DWH) blowout, there is need to "integrate more sophisticated risk assessment and risk management practices" in the oil industry. Reviewing the literature of the offshore drilling industry indicates that most of the developed risk analysis methodologies do not fully and more importantly, systematically address the contribution of Human and Organizational Factors (HOFs) in accident causation. This is while results of a comprehensive study, from 1988 to 2005, of more than 600 well-documented major failures in offshore structures show that approximately 80% of those failures were due to HOFs. In addition, lack of safety culture, as an issue related to HOFs, have been identified as a common contributing cause of many accidents in this industry. This dissertation introduces an integrated risk analysis methodology to systematically assess the critical role of human and organizational factors in offshore drilling safety. The proposed methodology in this research focuses on a specific procedure called Negative Pressure Test (NPT), as the primary method to ascertain well integrity during offshore drilling, and analyzes the contributing causes of misinterpreting such a critical test. In addition, the case study of the BP Deepwater Horizon accident and their conducted NPT is discussed. The risk analysis methodology in this dissertation consists of three different approaches and their integration constitutes the big picture of my whole methodology. The first approach is the comparative analysis of a "standard" NPT, which is proposed by the author, with the test conducted by the DWH crew. This analysis contributes to identifying the involved discrepancies between the two test procedures. The second approach is a conceptual risk assessment framework to analyze the causal factors of the identified mismatches in the previous step, as the main contributors of negative pressure test

  20. Peripheral Microvascular Responses to Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure Stresses in Humans

    Science.gov (United States)

    Breit, G. A.; Watenpaugh, D. E.; Buckley, T. M.; Ballard, R. E.; Murthy, G.; Hargens, A. R.

    1994-01-01

    The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.

  1. Combined non-adaptive light and smell stimuli lowered blood pressure, reduced heart rate and reduced negative affect.

    Science.gov (United States)

    Dong, Shan; Jacob, Tim J C

    2016-03-15

    Bright light therapy has been shown to have a positive impact on seasonal affective disorder (SAD), depression and anxiety. Smell has also has been shown to have effects on mood, stress, anxiety and depression. The objective of this study was to investigate the effect of the combination of light and smell in a non-adaptive cycle. Human subjects were given smell (lemon, lavender or peppermint) and light stimuli in a triangular wave (60scycle) for 15min. Blood pressure and heart rate were monitored before and after each session for 5 consecutive days and a Profile of Mood States (POMS) test was administered before and after the sensory stimulation on days 1, 3 and 5. The light-smell stimulus lowered blood pressure, both systolic and diastolic, and reduced heart rate for all odours compared to control. Of the two sensory stimuli, the odour stimulus contributed most to this effect. The different aromas in the light-smell combinations could be distinguished by their different effects on the mood factors with lemon inducing the greatest mood changes in Dejection-Depression, Anger-Hostility, Tension-Anxiety. In conclusion, combined light and smell stimulation was effective in lowering blood pressure, reducing heart rate and improving mood. The combination was more effective than either smell or light stimuli alone, suggesting that a light-smell combination would be a more robust and efficacious alternative treatment for depression, anxiety and stress. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Capillary Condensation in Confined Media

    OpenAIRE

    Charlaix, Elisabeth; Ciccotti, Matteo

    2009-01-01

    28 pages - To appear in 2010 in the Handbook of Nanophysics - Vol 1 - Edited by Klaus Sattler - CRC Press; We review here the physics of capillary condensation of liquids in confined media, with a special regard to the application in nanotechnologies. The thermodynamics of capillary condensation and thin film adsorption are first exposed along with all the relevant notions. The focus is then shifted to the modelling of capillary forces, to their measurements techniques (including SFA, AFM and...

  3. Capillary waves in slow motion

    International Nuclear Information System (INIS)

    Seydel, Tilo; Tolan, Metin; Press, Werner; Madsen, Anders; Gruebel, Gerhard

    2001-01-01

    Capillary wave dynamics on glycerol surfaces has been investigated by means of x-ray photon correlation spectroscopy performed at grazing angles. The measurements show that thermally activated capillary wave motion is slowed down exponentially when the sample is cooled below 273 K. This finding directly reflects the freezing of the surface waves. The wave-number dependence of the measured time constants is in quantitative agreement with theoretical predictions for overdamped capillary waves

  4. Capillary waves of compressible fluids

    International Nuclear Information System (INIS)

    Falk, Kerstin; Mecke, Klaus

    2011-01-01

    The interplay of thermal noise and molecular forces is responsible for surprising features of liquids on sub-micrometer lengths-in particular at interfaces. Not only does the surface tension depend on the size of an applied distortion and nanoscopic thin liquid films dewet faster than would be expected from hydrodynamics, but also the dispersion relation of capillary waves differ at the nanoscale from the familiar macroscopic behavior. Starting with the stochastic Navier-Stokes equation we study the coupling of capillary waves to acoustic surface waves which is possible in compressible fluids. We find propagating 'acoustic-capillary waves' at nanometer wavelengths where in incompressible fluids capillary waves are overdamped.

  5. Determination of stability constants of tauro- and glyco-conjugated bile salts with the negatively charged sulfobutylether-β-cyclodextrin: comparison of affinity capillary electrophoresis and isothermal titration calorimetry and thermodynamic analysis of the interaction

    DEFF Research Database (Denmark)

    Holm, René; Østergaard, Jesper; Schönbeck, Jens Christian Sidney

    2014-01-01

    The aim of the present work was to investigate the interaction between bile salts present in the intestine of man, dog and rat with the negatively charged cyclodextrin (CD), sulfobutylether-β-cyclodextrin (SBEβCD). The interactions between bile salts and CDs are of importance for the release of C...

  6. Fundamentals of negative refractive index optical trapping: forces and radiation pressures exerted by focused Gaussian beams using the generalized Lorenz-Mie theory.

    Science.gov (United States)

    Ambrosio, Leonardo A; Hernández-Figueroa, Hugo E

    2010-11-04

    Based on the generalized Lorenz-Mie theory (GLMT), this paper reveals, for the first time in the literature, the principal characteristics of the optical forces and radiation pressure cross-sections exerted on homogeneous, linear, isotropic and spherical hypothetical negative refractive index (NRI) particles under the influence of focused Gaussian beams in the Mie regime. Starting with ray optics considerations, the analysis is then extended through calculating the Mie coefficients and the beam-shape coefficients for incident focused Gaussian beams. Results reveal new and interesting trapping properties which are not observed for commonly positive refractive index particles and, in this way, new potential applications in biomedical optics can be devised.

  7. Effect of negative pressure therapy on repair of soft tissues of the lower extremities in patients with neuropathic and neuroischaemic forms of diabetic foot syndrome

    Directory of Open Access Journals (Sweden)

    Ekaterina Leonidovna Zaytseva

    2014-06-01

    Full Text Available AimTo evaluate the efficiency of topical negative pressure wound therapy (NPWT compared with standard therapy for the regeneration of the soft tissues of the lower extremities in patients with diabetic foot syndrome.Materials and MethodsThe effects of negative pressure therapy on the clinical (size, tissue oxygenation, histological (light microscopy and immunohistochemical (CD68, MMP-9, TIMP-1 aspects of repair of the soft tissue of the lower extremities in patients with diabetes mellitus were compared with those of standard treatment. Thirty-one patients with diabetic foot ulcers were included in the study from the moment of debridement until the plastic closure of the wound. During the perioperative period, 13 patients received NPWT (-90 to -120 mmHg and 18 patients received standard therapy.ResultsA reduction of the wound area (26.6%±17.2% and the depth of the defects (40.5%±25.6% were achieved with negative pressure therapy compared with baseline data. In the control group, the corresponding values were 25.3%±19.4% and 21.8%±21.6%, respectively. The results of transcutaneous oximetry showed a greater increase in the level of local hemodynamics in the study group (p <0.04. An important criterion for wound preparation for a plastic closure is filling it with granulation tissue by more than 75%. In the study group, 95% of patients had wounds filled with 89.9%±17% of abundant granulation tissue. The histological data of the study group show a significant reduction of oedema by 80% (p <0.05, improved extracellular matrix organization (p <0.05, 90% (p <0.05 dissolution of inflammatory infiltrate and the formation of healthy granulation tissue (p <0.05. Immunohistochemical analysis demonstrated a significant decrease in the number of macrophages in the dermis (CD68 expression (p <0.05. In both groups, the level of MMP-9 was decreased. However, the ratio of MMP-9:TIMP-1 was lower in the study group (p <0.05.ConclusionThe findings suggest that

  8. On Capillary Rise and Nucleation

    Science.gov (United States)

    Prasad, R.

    2008-01-01

    A comparison of capillary rise and nucleation is presented. It is shown that both phenomena result from a balance between two competing energy factors: a volume energy and a surface energy. Such a comparison may help to introduce nucleation with a topic familiar to the students, capillary rise. (Contains 1 table and 3 figures.)

  9. Mechanisms underlying the volume regulation of interstitial fluid by capillaries: a simulation study

    Directory of Open Access Journals (Sweden)

    Yukiko Himeno

    2016-03-01

    Conclusion: Mathematical analyses revealed that the system of the capillary is stable near the equilibrium point at steady state and normal physiological capillary pressure. The time course of the tissue-volume change was determined by two kinetic mechanisms: rapid fluid exchange and slow protein fluxes.

  10. Effect of Leaf Water Potential on Internal Humidity and CO2 Dissolution: Reverse Transpiration and Improved Water Use Efficiency under Negative Pressure.

    Science.gov (United States)

    Vesala, Timo; Sevanto, Sanna; Grönholm, Tiia; Salmon, Yann; Nikinmaa, Eero; Hari, Pertti; Hölttä, Teemu

    2017-01-01

    The pull of water from the soil to the leaves causes water in the transpiration stream to be under negative pressure decreasing the water potential below zero. The osmotic concentration also contributes to the decrease in leaf water potential but with much lesser extent. Thus, the surface tension force is approximately balanced by a force induced by negative water potential resulting in concavely curved water-air interfaces in leaves. The lowered water potential causes a reduction in the equilibrium water vapor pressure in internal (sub-stomatal/intercellular) cavities in relation to that over water with the potential of zero, i.e., over the flat surface. The curved surface causes a reduction also in the equilibrium vapor pressure of dissolved CO 2 , thus enhancing its physical solubility to water. Although the water vapor reduction is acknowledged by plant physiologists its consequences for water vapor exchange at low water potential values have received very little attention. Consequences of the enhanced CO 2 solubility to a leaf water-carbon budget have not been considered at all before this study. We use theoretical calculations and modeling to show how the reduction in the vapor pressures affects transpiration and carbon assimilation rates. Our results indicate that the reduction in vapor pressures of water and CO 2 could enhance plant water use efficiency up to about 10% at a leaf water potential of -2 MPa, and much more when water potential decreases further. The low water potential allows for a direct stomatal water vapor uptake from the ambient air even at sub-100% relative humidity values. This alone could explain the observed rates of foliar water uptake by e.g., the coastal redwood in the fog belt region of coastal California provided the stomata are sufficiently open. The omission of the reduction in the water vapor pressure causes a bias in the estimates of the stomatal conductance and leaf internal CO 2 concentration based on leaf gas exchange

  11. Capillary optics for radiation focusing

    International Nuclear Information System (INIS)

    Peurrung, A.J.; Reeder, P.L.; Bliss, M.; Craig, R.A.; Lepel, E.A.; Stromswold, D.C.; Stoffels, J.; Sunberg, D.S.; Tenny, H.

    1996-11-01

    Capillary lens technology may ultimately bring benefits to neutron and x-ray-based science like conventional lenses with visible light. Although the technology is not yet 10 years old, these lenses have already had a significant impact in engineering, science, and medicine. Capillary lenses are advantageous when it is desirable to increase the radiation flux at a location without regard to its angular divergence. PNNL has worked to improve the technology in several ways. A single, optimally tapered capillary was manufactured, which allows intensity gains of a factor of 270 for an initially parallel, incident x-ray beam. Feasibility of constructing neutron lenses using 58 Ni (particularly effective at reflecting neutrons) has been explored. Three applications for capillary optics have been identified and studied: neutron telescope, Gandolphi x-ray diffractometry, and neutron radiotherapy. A brief guide is given for determining which potential applications are likely to be helped by capillary optics

  12. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  13. Biomedical applications of capillary electrophoresis

    International Nuclear Information System (INIS)

    Kartsova, L A; Bessonova, E A

    2015-01-01

    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references

  14. The order of condensation in capillary grooves

    International Nuclear Information System (INIS)

    Rascón, Carlos; Parry, Andrew O; Nürnberg, Robert; Pozzato, Alessandro; Tormen, Massimo; Bruschi, Lorenzo; Mistura, Giampaolo

    2013-01-01

    We consider capillary condensation in a deep groove of width L. The transition occurs at a pressure p co (L) described, for large widths, by the Kelvin equation p sat − p co (L) = 2σcosθ/L, where θ is the contact angle at the side walls and σ is the surface tension. The order of the transition is determined by the contact angle of the capped end θ cap ; it is continuous if the liquid completely wets the cap, and first-order otherwise. When the transition is first-order, corner menisci at the bottom of the capillary lead to a pronounced metastability, determined by a complementary Kelvin equation Δp(L) = 2σsinθ cap /L. On approaching the wetting temperature of the capillary cap, the corner menisci merge and a single meniscus unbinds from the bottom of the groove. Finite-size scaling shifts, crossover behaviour and critical singularities are determined at mean-field level and beyond. Numerical and experimental results showing the continuous nature of condensation for θ cap = 0 and the influence of corner menisci on adsorption isotherms are presented. (fast track communication)

  15. The order of condensation in capillary grooves.

    Science.gov (United States)

    Rascón, Carlos; Parry, Andrew O; Nürnberg, Robert; Pozzato, Alessandro; Tormen, Massimo; Bruschi, Lorenzo; Mistura, Giampaolo

    2013-05-15

    We consider capillary condensation in a deep groove of width L. The transition occurs at a pressure p(co)(L) described, for large widths, by the Kelvin equation p(sat) - p(co)(L) = 2σ cosθ/L, where θ is the contact angle at the side walls and σ is the surface tension. The order of the transition is determined by the contact angle of the capped end θcap; it is continuous if the liquid completely wets the cap, and first-order otherwise. When the transition is first-order, corner menisci at the bottom of the capillary lead to a pronounced metastability, determined by a complementary Kelvin equation Δp(L) = 2σ sinθcap/L. On approaching the wetting temperature of the capillary cap, the corner menisci merge and a single meniscus unbinds from the bottom of the groove. Finite-size scaling shifts, crossover behaviour and critical singularities are determined at mean-field level and beyond. Numerical and experimental results showing the continuous nature of condensation for θcap = 0 and the influence of corner menisci on adsorption isotherms are presented.

  16. LASER PLASMA AND LASER APPLICATIONS: Plasma transparency in laser absorption waves in metal capillaries

    Science.gov (United States)

    Anisimov, V. N.; Kozolupenko, A. P.; Sebrant, A. Yu

    1988-12-01

    An experimental investigation was made of the plasma transparency to heating radiation in capillaries when absorption waves propagated in these capillaries as a result of interaction with a CO2 laser pulse of 5-μs duration. When the length of the capillary was in excess of 20 mm, total absorption of the radiation by the plasma was observed at air pressures of 1-100 kPa. When the capillary length was 12 mm, a partial recovery of the transparency took place. A comparison was made with the dynamics and recovery of the plasma transparency when breakdown of air took place near the free surface.

  17. Physiological factors influencing capillary growth.

    Science.gov (United States)

    Egginton, S

    2011-07-01

    (1) Angiogenesis (growth of new capillaries from an existing capillary bed) may result from a mismatch in microvascular supply and metabolic demand (metabolic error signal). Krogh examined the distribution and number of capillaries to explore the correlation between O(2) delivery and O(2) consumption. Subsequently, the heterogeneity in angiogenic response within a muscle has been shown to reflect either differences in fibre type composition or mechanical load. However, local control leads to targetted angiogenesis in the vicinity of glycolytic fibre types following muscle stimulation, or oxidative fibres following endurance training, while heterogeneity of capillary spacing is maintained during ontogenetic growth. (2) Despite limited microscopy resolution and lack of specific markers, Krogh's interest in the structure of the capillary wall paved the way for understanding the mechanisms of capillary growth. Angiogenesis may be influenced by the response of perivascular or stromal cells (fibroblasts, macrophages and pericytes) to altered activity, likely acting as a source for chemical signals modulating capillary growth such as vascular endothelial growth factor. In addition, haemodynamic factors such as shear stress and muscle stretch play a significant role in adaptive remodelling of the microcirculation. (3) Most indices of capillarity are highly dependent on fibre size, resulting in possible bias because of scaling. To examine the consequences of capillary distribution, it is therefore helpful to quantify the area of tissue supplied by individual capillaries. This allows the spatial limitations inherent in most models of tissue oxygenation to be overcome generating an alternative approach to Krogh's tissue cylinder, the capillary domain, to improve descriptions of intracellular oxygen diffusion. © 2010 The Author. Acta Physiologica © 2010 Scandinavian Physiological Society.

  18. Spectroscopic diagnosis of plasma in atmospheric pressure negative pulsed gas-liquid discharge with nozzle-cylinder electrode

    Science.gov (United States)

    Ming, SUN; Zhan, TAO; Zhipeng, ZHU; Dong, WANG; Wenjun, PAN

    2018-05-01

    The plasma characteristics of a gas-liquid phase discharge reactor were investigated by optical and electrical methods. The nozzle-cylinder electrode in the discharge reactor was supplied with a negative nanosecond pulsed generator. The optical emission spectrum diagnosis revealed that OH (A2∑+ → X2Π, 306–309 nm), N2 (C3Π→B3Πg, 337 nm), O (3p5p→3s5s0, 777.2 nm) and O (3p3p→3s3s0, 844.6 nm) were produced in the discharge plasma channels. The electron temperature (T e) was calculated from the emission relative intensity ratio between the atomic O 777.2 nm and 844.6 nm, and it increased with the applied voltage and the pulsed frequency and fell within the range of 0.5–0.8 eV. The gas temperature (T g) that was measured by Lifbase was in a range from 400 K to 600 K.

  19. Imbibition Triggered by Capillary Condensation in Nanopores.

    Science.gov (United States)

    Vincent, Olivier; Marguet, Bastien; Stroock, Abraham D

    2017-02-21

    We study the spatiotemporal dynamics of water uptake by capillary condensation from unsaturated vapor in mesoporous silicon layers (pore radius r p ≃ 2 nm), taking advantage of the local changes in optical reflectance as a function of water saturation. Our experiments elucidate two qualitatively different regimes as a function of the imposed external vapor pressure: at low vapor pressures, equilibration occurs via a diffusion-like process; at high vapor pressures, an imbibition-like wetting front results in fast equilibration toward a fully saturated sample. We show that the imbibition dynamics can be described by a modified Lucas-Washburn equation that takes into account the liquid stresses implied by Kelvin equation.

  20. Abdominal Cavity Eventration Treated by Means of the "Open Abdomen" Technique Using the Negative Pressure Therapy System--Case Report and Literature Review.

    Science.gov (United States)

    Trzeciak, Piotr W; Porzeżyńska, Joanna; Ptasińska, Karolina; Walczak, Dominik A

    2015-11-01

    Wound dehiscence is a surgical complication in which the wound ruptures along the surgical suture with abdominal cavity bowel displacement. It is observed in 0.2-6% of operated patients. The extensive wound is a gateway for infection. Moreover, increased secretion of serous fluid induces a hygienic problem and may lead to secondary skin infections or bedsores. The negative pressure wound therapy (NPWT) system is an innovative therapeutic method. It perfectly executes the TIME strategy, receiving more and more recognition. The study presented a case of a 62-year old male patient after several consecutive wound dehiscence episodes who was primarily treated for rectal cancer by means of low anterior resection of the rectum. Due to acute respiratory insufficiency after several operations, wound necrosis with dehiscence was observed. Considering the high risk of perioperative death we abandoned surgical treatment and introduced conservative management using negative pressure wound therapy until the patient's health improved. Literature regarding the above-mentioned issue was also reviewed.

  1. The SNaP™ Wound Care System: A Case Series Using a Novel Ultraportable Negative Pressure Wound Therapy Device for the Treatment of Diabetic Lower Extremity Wounds

    Science.gov (United States)

    Lerman, Bruce; Oldenbrook, Leslie; Ryu, Justin; Fong, Kenton D.; Schubart, Peter J.

    2010-01-01

    Although there is significant evidence supporting the use of negative pressure wound therapy (NPWT) for the treatment of lower extremity diabetic ulcers, currently available electrically powered NPWT systems are not ideally suited for treating smaller diabetic foot ulcers. The Smart Negative Pressure (SNaP™) Wound Care System is a novel, ultraportable device that delivers NPWT without the use of an electrically powered pump. It was specifically designed to meet the wound care needs of patients with diabetes. The SNaP System is compact, silent, mobile, easy-to-use, and available off-the-shelf. It is fully disposable and may offer other important benefits over electrically powered systems to both the clinician and patient. We review the evidence for use of NPWT for the treatment of diabetic wounds and discuss the potential benefits of this new NPWT technology for patients with diabetes. We also present a case series of four difficult lower extremity diabetic ulcers that were successfully treated with the SNaP System. This study suggests that the SNaP System may be a useful addition to the armamentarium of the diabetic wound care clinician. PMID:20663444

  2. Stagnations of increasing trends in negative pressure with repeated cavitation in water/metal Berthelot tubes as a result of mechanical sealing

    International Nuclear Information System (INIS)

    Hiro, Kazuki; Ohde, Yoshihito; Tanzawa, Yasutoshi

    2003-01-01

    To investigate effects of mechanical sealing on negative pressures in water/metal tube Berthelot systems, trends in negative pressure are observed through runs of temperature cycles below 90 deg. C in two systems made of metals having small amounts of gas inclusions. The first system is a pre-degassed all-stainless-steel tube/plug system. The steel is a special product for vacuum engineering. The second is the same tube sealed with plugs made of silver solidified one-dimensionally in a vacuum furnace. A new type of trend, stagnation for intermediate cycles is found in both systems so long as sealing distortion of each plug is small in amount. The stagnation period for the first system is longer than that for the second one. A metallurgical mechanism of a gas-being-replenished crevice model is proposed: distorted parts of metals undergo heat-treatment during runs of temperature cycles, and the heat-treatment enhances the rates of impurity gas transports to crevices on the metal surface where cavitation occurs, and the transport causes the stagnation for cycles during which the rates are still high

  3. Laws of physics help explain capillary non-perfusion in diabetic retinopathy.

    Science.gov (United States)

    Stefánsson, E; Chan, Y K; Bek, T; Hardarson, S H; Wong, D; Wilson, D I

    2018-02-01

    The purpose is to use laws of physics to elucidate the mechanisms behind capillary non-perfusion in diabetic retinopathy. In diabetic retinopathy, loss of pericytes weakens capillary walls and the vessel dilates. A dilated capillary has reduced resistance to flow, therefore increased flow in that vessel and decreased in adjoining capillaries. A preferential shunt vessel is thus formed from the dilated capillary and the adjacent capillaries become non-perfused. We apply the laws of Laplace and Hagen-Poiseuille to better understand the phenomena that lead to capillary non-perfusion. These laws of physics can give a foundation for physical or mathematical models to further elucidate this field of study. The law of Laplace predicts that a weaker vessel wall will dilate, assuming constant transmural pressure. The Hagen-Poiseuille equation for flow and the Ostwald-de Waele relationship for viscosity predict that a dilated vessel will receive a higher portion of the fluid flow than the adjoining capillaries. Viscosity will decrease in the dilated vessel, furthering the imbalance and resulting in a patch of non-perfused capillaries next to the dilated 'preferential' shunt vessel. Physical principles support or inspire novel hypotheses to explain poorly understood phenomena in ophthalmology. This thesis of pericyte death and capillary remodelling, which was first proposed by Cogan and Kuwabara, already agrees with histological and angiographical observations in diabetic retinopathy. We have shown that it is also supported by classical laws of physics.

  4. Gravimetric capillary method for kinematic viscosity measurements

    Science.gov (United States)

    Rosenberger, Franz; Iwan, J.; Alexander, D.; Jin, Wei-Qing

    1992-01-01

    A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

  5. Time effectiveness of capillary effect improvement of ramie fabrics processed by RF glow discharging

    International Nuclear Information System (INIS)

    Wang Zhiwen; Wei Weixing; He Yanhe; Zhao Yuanqing; Pan Liyiji; Li Xuemei; Shi Shaodui; Li Guangxin

    2010-01-01

    The time effectiveness of capillary effect improvement of ramie fabrics processed by RF glow discharging was studied. The ramie fabrics were processed in fulfilling with different gas (O 2 , N 2 , Ar) by different parameters (such as pressure,power and time) plasma. The capillary effect of the ramie fabrics processed by RF glow discharging was tested at different time. The results indicate that the capillary effect of ramie fabrics processed by RF glow discharging has been improved, the improvement of the capillary effect firstly decrease rapidly, then slowly, and become stable after 15 day, it indicate that improvement of the ramie fabrics capillary has good time effectiveness, and the plasma parameter for the best capillary effect improvement of ramie fabric is 100 W and 40 Pa processed 20 min by oxygen plasma. (authors)

  6. Capillaries for use in a multiplexed capillary electrophoresis system

    Science.gov (United States)

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  7. Tissue Oxygenation and Negative-Pressure Wound Therapy When Applied to the Feet of Persons With Diabetes Mellitus: An Observational Study.

    Science.gov (United States)

    Lee, Ye-Na; Lee, Jong Seok; Han, Seung-Kyu; Jung, Hye-Kyung

    Our group has reported that negative-pressure wound therapy (NPWT) decreases tissue oxygenation by 84% in the foot of diabetic patients because the pad of the connecting drainage tube and foam sponge of the NPWT system compress the wound bed. The purpose of this study was to determine whether an NPWT modified dressing application reduces tissue oxygenation in the feet of persons with diabetes mellitus. A prospective, clinical, observational study. We enrolled 30 patients with diabetic mellitus; their mean age was 63.9 ± 11.2 years (mean ± standard deviation). All were cared for at the diabetic wound center at an academic tertiary medical center in South Korea between 2014 and January 2015. Transcutaneous partial oxygen pressures (TcpO2) were measured to determine tissue oxygenation levels beneath modified NPWT dressings. A TcpO2 sensor was fixed at the tarsometatarsal area of the contralateral unwounded foot. A negative pressure of -125 mm Hg was applied until TcpO2 reached a plateau state; values were measured before, during, and after the modified NPWT. The Wilcoxon' and Mann-Whitney U tests were used to compare differences between these measurements. TcpO2 levels decreased by 26% during the modified NPWT. Mean TcpO2 values before, during, and after turning off the therapy were 54.3 ± 15.3 mm Hg, 41.6 ± 16.3 mm Hg, and 53.3 ± 15.6 mm Hg (P drainage tube significantly reduces the amount of tissue oxygenation loss beneath foam dressings on the skin of the foot dorsum in diabetic patients.

  8. The effect of positive and negative message framing on short term continuous positive airway pressure compliance in patients with obstructive sleep apnea.

    Science.gov (United States)

    Pengo, Martino F; Czaban, Marcin; Berry, Marc P; Nirmalan, Prajeshan; Brown, Richard; Birdseye, Adam; Woroszyl, Asia; Chapman, Julia; Kent, Brian D; Hart, Nicholas; Rossi, Gian Paolo; Steier, Joerg

    2018-01-01

    Continuous positive airway pressure (CPAP), the best available treatment for obstructive sleep apnea (OSA), requires long-term compliance to be effective. Behavioral interventions may be used to improve adherence to CPAP. We aimed to investigate whether positive or negative message framing impacts on CPAP compliance in patients with OSA, when compared to standard care. Consenting patients with confirmed OSA were randomly allocated to receive along with their CPAP either positively or negatively framed messages (Pos; Neg), or standard care (Con). Standardized motivational messages were read out to patients during an initial teaching session and through weekly telephone calls. Patients' compliance data were reviewed 2 and 6 weeks following CPAP initiation. We randomized 112 patients to groups that were matched for age, BMI, and OSA severity. The positively framed group (Pos) showed greater CPAP usage after 2 weeks (total use 53.7±31.4 hours) as compared to the negatively framed and the control group (35.6±27.4 and 40.8±33.5 hours, Pframed groups (Pos n=5; Neg n=8; Con n=11; Pframed messages can improve CPAP adherence in patients with OSA in the short-term; however, strategies for implementing its long-term use need to be developed.

  9. The dissipative flow of superfluid helium-3 through capillaries

    International Nuclear Information System (INIS)

    Kopnin, N.B.

    1986-01-01

    The equations are obtained which describe the behaviour of the chemical potential (pressure) of the superfluid helium-3 flowing through a narrow capillary, diffusively scattering boundaries being taken into consideration. The possibility is discussed whether the dissipation experimentally observed by Manninen and Pekola can be understood in terms of the phase-slip process

  10. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Zeeshan Ahmed

    2016-01-01

    Conclusion: Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE.

  11. Management of the open abdomen using negative pressure wound therapy with instillation in severe abdominal sepsis: A review of 48 cases in Hospital Mexico, Costa Rica.

    Science.gov (United States)

    Sibaja, Pablo; Sanchez, Alfredo; Villegas, Guillermo; Apestegui, Alvaro; Mora, Esteban

    2017-01-01

    Despite the numerous advances in recent years, severe abdominal sepsis (with associated organ failure associated with infection) remains a serious, life-threatening condition with a high mortality rate. OA is a viable alternative to the previously used scheduled repeat laparotomy or continuous peritoneal lavage. The use of Negative Pressure Wound Therapy (NPWT) has been described as a successful method of management of the open abdomen. Adding instillation of saline solution to NPWT in a programmed and controlled manner, could offer the clinician an additional tool for the management of complex septic abdomen. To explore if the concept of active two-way therapy (Negative pressure wound therapy with instillation or NPWT-I) yields superior control of underlying, life-threatening abdominal infections and its effects on survival and morbidity in patients with severe abdominal sepsis when management with an open abdomen is required. A retrospective review of 48 patients with severe abdominal sepsis, who were managed with and open abdomen and NPWT-I was performed. NPWT-I was initiated utilizing the same parameters on all patients, this consisted of cycles of instillation of saline solution, which was removed through negative pressure after a short dwell period. We observed the effects on primary fascia closure rate, mortality, hospital and SICU length of stay and associated complications. Our patient group consisted of 20 (42%) males and 28 (58%) females. Average age was 48 years. Mortality in these patients was attributed to pulmonary embolism (n=1), acute renal failure (n=2) and cardiopulmonary arrest (n=1). Average total hospital stay was 24days, and stay in the SICU (n=26) averaged 7.5days. No acute complications related to the NPWT-I. All patients presenting with abdominal compartment syndrome resolved after initiation of the NPWT-I. A total of 46 patients (96%) patients achieved fascia closure after NPWT-I therapy after an average of 6days. Four patients (8%) died

  12. Capillary Pumped Heat Transfer (CHT) Experiment

    Science.gov (United States)

    Hallinan, Kevin P.; Allen, J. S.

    1998-01-01

    The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

  13. Capillary gas-solid chromatography

    International Nuclear Information System (INIS)

    Berezkin, V.G.

    1996-01-01

    Modern state of gas adsorption chromatography in open capillary columns has been analyzed. The history of the method development and its role in gas chromatography, ways to construct open adsorptional capillary columns, foundations of the theory of retention and washing of chromatographic regions in gas adsorption capillary columns have been considered. The fields is extensively and for analyzing volatile compounds of different isotopic composition, inorganic and organic gases, volatile organic polar compounds, aqueous solutions of organic compounds. Separation of nuclear-spin isomers and isotopes of hydrogen is the first illustrative example of practical application of the adsorption capillary chromatography. It is shown that duration of protium and deuterium nuclear isomers may be reduced if the column temperature is brought to 47 K

  14. DNA typing by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1997-10-08

    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  15. Aerial medical evacuation of health workers with suspected Ebola virus disease in Guinea Conakry-interest of a negative pressure isolation pod-a case series.

    Science.gov (United States)

    Dindart, Jean-Michel; Peyrouset, Olivier; Palich, Romain; Bing, Abdoul; Kojan, Richard; Barbe, Solenne; Harouna, Souley; Blackwell, Nikki

    2017-03-11

    We report 4 cases of Health Workers (HW) suspected of having contracted Ebola Virus Disease (EVD), transported from the Alliance for International Medical Action (ALIMA) Ebola Treatment Centre (ETC) in N'Zerekore, Guinea to the Treatment Centre for Carers run by the medical corps of the French army in Conakry, the capital of Guinea, which was established on 17 January 2015 and closed on 7 July 2015. In total more than 500 HWs have died from EVD since the epidemic began. This mortality has had significant effects on the ability of local services to respond appropriately to the disaster. The HWs were transported by air in the "Human Stretcher Transit Isolator-Total Containment (Oxford) Limited" (HSTI-TCOL) negative pressure isolation pod. Medical evacuation of patients with suspected, potentially fatal, infectious diseases is feasible with the use of a light isolator for patients without critical dysfunctions.

  16. Capillary viscosimetry on ferrofluids

    International Nuclear Information System (INIS)

    Pop, L M; Odenbach, S

    2008-01-01

    Experiments performed for different ferrofluids under shear flow have shown that an increase of the magnetic field strength applied to the sample yields an increase of the fluid's viscosity, the so called magnetoviscous effect. It has been shown that the magnitude of the effect is strongly related to the modification of the microstructure of ferrofluids and can be influenced by varying both the dipole-dipole interaction between the particles and the concentration of large particles within the fluid. This result has been further used to synthesize new ferrofluids which, on one hand, are more compatible for technical applications but, on the other hand, led to difficulties for the experimenters in measuring the viscous behavior in the presence of a magnetic field. To overcome this problem, a specially designed ferrofluid-compatible capillary viscometer has been developed. Within this paper, the experimental setup as well as experimental results concerning the investigation of the magnetoviscous effect in both diluted and concentrated cobalt-based ferrofluids are presented

  17. Foliar δ13C Showed No Altitudinal Trend in an Arid Region and Atmospheric Pressure Exerted a Negative Effect on Plant δ13C

    Directory of Open Access Journals (Sweden)

    Zixun Chen

    2017-07-01

    Full Text Available Previous studies have suggested foliar δ13C generally increases with altitude. However, some observations reported no changes or even decreased trends in foliar δ13C. We noted that all the studies in which δ13C increased with elevation were conducted in the human regions, whereas those investigations in which δ13C did not vary or decreased were conducted in areas with water stress. Thus, we proposed that the pattern of increasing δ13C with elevation is not a general one, and that δ13C may remain unchanged or decrease in plants grown in arid environments. To test the hypothesis, we sampled plants along altitude gradients on the shady and sunny slopes of Mount Tianshan characterized by arid and semiarid climates. The measurements of foliar δ13C showed no altitudinal trends for the plants grown on either of the slopes. Therefore, this study supported our hypothesis. In addition, the present study addressed the effect of atmospheric pressure on plant δ13C by accounting for the effects of temperature and precipitation on δ13C. This study found that the residual foliar δ13C increased with increasing altitude, suggesting that atmospheric pressure played a negative role in foliar δ13C.

  18. New type of capillary for use as ion beam collimator and air-vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Stoytschew, V., E-mail: valostoytschew@hotmail.com [Ruđer Bošković Institute, Bijenicka Cesta 54, 10000 Zagreb (Croatia); Schulte-Borchers, M. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, CH-8093 Zurich (Switzerland); Božičević Mihalića, Iva [Ruđer Bošković Institute, Bijenicka Cesta 54, 10000 Zagreb (Croatia); Perez, R.D. [FaMAF, Universidad Nacional de Córdoba, (5000) Ciudad Universitaria, Córdoba (Argentina)

    2016-08-01

    Glass capillaries offer a unique way to combine small diameter ion beam collimation with an air-vacuum interface for ambient pressure ion beam applications. Usually they have an opening diameter of a few microns, limiting the air inflow sufficiently to maintain stable conditions on the vacuum side. As the glass capillaries generally are quite thin and fragile, handling of the capillary in the experiment becomes difficult. They also introduce an X-ray background produced by the capillary wall material, which has to be shielded or subtracted from the data for Particle Induced X-ray Emission (PIXE) applications. To overcome both drawbacks, a new type of conical glass capillary has been developed. It has a higher wall thickness eliminating the low energy X-ray background produced by common capillaries and leading to a more robust lens. The results obtained in first tests show, that this new capillary is suitable for ion beam collimation and encourage further work on the capillary production process to provide thick wall capillaries with an outlet diameter in the single digit micro- or even nanometre range.

  19. Using evaporation to control capillary instabilities in micro-systems.

    Science.gov (United States)

    Ledesma-Aguilar, Rodrigo; Laghezza, Gianluca; Yeomans, Julia M; Vella, Dominic

    2017-12-06

    The instabilities of fluid interfaces represent both a limitation and an opportunity for the fabrication of small-scale devices. Just as non-uniform capillary pressures can destroy micro-electrical mechanical systems (MEMS), so they can guide the assembly of novel solid and fluid structures. In many such applications the interface appears during an evaporation process and is therefore only present temporarily. It is commonly assumed that this evaporation simply guides the interface through a sequence of equilibrium configurations, and that the rate of evaporation only sets the timescale of this sequence. Here, we use Lattice-Boltzmann simulations and a theoretical analysis to show that, in fact, the rate of evaporation can be a factor in determining the onset and form of dynamical capillary instabilities. Our results shed light on the role of evaporation in previous experiments, and open the possibility of exploiting diffusive mass transfer to directly control capillary flows in MEMS applications.

  20. Incisional Negative Pressure Wound Therapy

    DEFF Research Database (Denmark)

    Hyldig, Nana; Birke-Sorensen, Hanne; Kruse, Marie

    and meta-analysis of randomized controlled trials of NPWT compared to standard postoperative dressings on closed incisions. Results: Ten studies met the inclusion criteria, reporting on 1344 incisions (1121 patients). NPWT was associated with a significant reduction of wound infection (46%), and seroma...... formation (52%) compared to standard care. The reduction in wound dehiscence was not statistically significant. The numbers needed to treat were 3 (seroma), 17 (dehiscence), and 25 (infection). Methodical heterogeneity across studies led to downgrading quality of evidence to moderate for infection...

  1. Pressure Effect on Extensional Viscosity

    DEFF Research Database (Denmark)

    Christensen, Jens Horslund; Kjær, Erik Michael

    1999-01-01

    The primary object of these experiments was to investigate the influence of hydrostatic pressure on entrance flow. The effect of pressure on shear and extensional viscosity was evaluated using an axis symmetric capillary and a slit die where the hydrostatic pressure was raised with valves....... The experiments show a significant increase in extensional viscosity with increasing pressure....

  2. Direct Numerical Simulation of Low Capillary Number Pore Scale Flows

    Science.gov (United States)

    Esmaeilzadeh, S.; Soulaine, C.; Tchelepi, H.

    2017-12-01

    The arrangement of void spaces and the granular structure of a porous medium determines multiple macroscopic properties of the rock such as porosity, capillary pressure, and relative permeability. Therefore, it is important to study the microscopic structure of the reservoir pores and understand the dynamics of fluid displacements through them. One approach for doing this, is direct numerical simulation of pore-scale flow that requires a robust numerical tool for prediction of fluid dynamics and a detailed understanding of the physical processes occurring at the pore-scale. In pore scale flows with a low capillary number, Eulerian multiphase methods are well-known to produce additional vorticity close to the interface. This is mainly due to discretization errors which lead to an imbalance of capillary pressure and surface tension forces that causes unphysical spurious currents. At the pore scale, these spurious currents can become significantly stronger than the average velocity in the phases, and lead to unphysical displacement of the interface. In this work, we first investigate the capability of the algebraic Volume of Fluid (VOF) method in OpenFOAM for low capillary number pore scale flow simulations. Afterward, we compare VOF results with a Coupled Level-Set Volume of Fluid (CLSVOF) method and Iso-Advector method. It has been shown that the former one reduces the VOF's unphysical spurious currents in some cases, and both are known to capture interfaces sharper than VOF. As the conclusion, we will investigate that whether the use of CLSVOF or Iso-Advector will lead to less spurious velocities and more accurate results for capillary driven pore-scale multiphase flows or not. Keywords: Pore-scale multiphase flow, Capillary driven flows, Spurious currents, OpenFOAM

  3. Image-Based Modeling of Blood Flow and Oxygen Transfer in Feto-Placental Capillaries.

    Directory of Open Access Journals (Sweden)

    Philip Pearce

    Full Text Available During pregnancy, oxygen diffuses from maternal to fetal blood through villous trees in the placenta. In this paper, we simulate blood flow and oxygen transfer in feto-placental capillaries by converting three-dimensional representations of villous and capillary surfaces, reconstructed from confocal laser scanning microscopy, to finite-element meshes, and calculating values of vascular flow resistance and total oxygen transfer. The relationship between the total oxygen transfer rate and the pressure drop through the capillary is shown to be captured across a wide range of pressure drops by physical scaling laws and an upper bound on the oxygen transfer rate. A regression equation is introduced that can be used to estimate the oxygen transfer in a capillary using the vascular resistance. Two techniques for quantifying the effects of statistical variability, experimental uncertainty and pathological placental structure on the calculated properties are then introduced. First, scaling arguments are used to quantify the sensitivity of the model to uncertainties in the geometry and the parameters. Second, the effects of localized dilations in fetal capillaries are investigated using an idealized axisymmetric model, to quantify the possible effect of pathological placental structure on oxygen transfer. The model predicts how, for a fixed pressure drop through a capillary, oxygen transfer is maximized by an optimal width of the dilation. The results could explain the prevalence of fetal hypoxia in cases of delayed villous maturation, a pathology characterized by a lack of the vasculo-syncytial membranes often seen in conjunction with localized capillary dilations.

  4. Western blotting using capillary electrophoresis.

    Science.gov (United States)

    Anderson, Gwendolyn J; M Cipolla, Cynthia; Kennedy, Robert T

    2011-02-15

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein adsorption. Although discrete protein zones could be detected, bands were broadened by ∼1.7-fold by transfer to membrane. A complete Western blot for lysozyme was completed in about one hour with 50 pg mass detection limit from low microgram per milliliter samples. These results demonstrate substantial reduction in time requirements and improvement in mass sensitivity compared to conventional Western blots. Western blotting using capillary electrophoresis shows promise to analyze low volume samples with reduced reagents and time, while retaining the information content of a typical Western blot.

  5. Numerical analysis of scaling laws for capillary rise in soils; Lois d'echelle pour l'ascension capillaire dans les sols: analyse numerique

    Energy Technology Data Exchange (ETDEWEB)

    Rezzoug, A.; Konig, D.; Triantafyllidis, Th. [Ruhr Bochum Univ. (Germany); Coumoulos, H.; Soga, K. [Cambridge Univ. (United Kingdom)

    2000-07-01

    The capillary movement of water through soils is of interest in many practical environmental engineering problems, especially problems concerning pollutant transport in soils. The potential use of the geotechnical centrifuge to study the capillary phenomena in soils has been proposed and some results have been reported. The main issue in relation is the verification of the scaling laws for the capillary phenomena in soils. However, the theoretical aspect of the capillary rise in relation to the accelerated gravity effect is still poorly understood; further investigation is required on the gravity effect on the capillary pressure, the meniscus form, the scaling of the capillary height and the scaling of the time. A theoretical analysis of the movement in capillary tube, representing soil, is presented. Scaling laws for the capillary height and the time are proposed. The effect of the contact angle changes on the scaling laws is also considered. (authors)

  6. Flow Analysis of Isobutane (R-600A) Inside AN Adiabatic Capillary Tube

    Science.gov (United States)

    Alok, Praveen; Sahu, Debjyoti

    2018-02-01

    Capillary tubes are simple narrow tubes but the phase change which occurs inside the capillary tubes is complex to analyze. In the present investigation, an attempt is made to analyze the flow of Isobutane (R-600a) inside the coiled capillary tubes for different load conditions by Homogeneous Equilibrium Model. The Length and diameter of the capillary tube not only depend on the pressure and temperature of the condenser and evaporator but also on the cooling load. The present paper investigates the change in dimensions of the coil capillary tube with respect to the change in cooling load on the system for the constant condenser and evaporator conditions. ANSYS CFX (Central Florida Expressway) software is used to study the flow characteristics of the refrigerant. Appropriate helical coil is selected for this analysis.

  7. Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

    Science.gov (United States)

    Watenpaugh, D. E.; Breit, G. A.; Ballard, R. E.; Murthy, G.; Hargens, A. R.

    1994-01-01

    Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore

  8. Weight-controlled capillary viscometer

    Science.gov (United States)

    Digilov, Rafael M.; Reiner, M.

    2005-11-01

    The draining of a water column through a vertical discharge capillary tube is examined with the aid of a force sensor. The change of the mass of the liquid in the column with time is found to be not purely exponential as implied by Poiseuille's law. Using observed residuals associated with a kinetic energy correction, an approximate formula for the mass as a function of time is derived and excellent agreement with experimental data is attained. These results are verified by a viscosity test of distilled water at room temperature. A simple and inexpensive weight-controlled capillary viscometer is proposed that is especially suitable for undergraduate physics and chemistry laboratories.

  9. Genetic variability of Artemisia capillaris (Wormwood capillary) by ...

    African Journals Online (AJOL)

    The genetic variability among individuals of Artemisia capillaris from state of Terengganu, Malaysia was examined by using the random amplified polymorphic DNA (RAPD) technique. The samples were collected from differences regional in Terengganu State. The genomic DNA was extracted from the samples leaves.

  10. Negative pressure driven valence instability of Eu in cubic Eu{sub 0.4}La{sub 0.6}Pd{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Abhishek [S N Bose National Centre for Basic Sciences, Block-JD, Sector-III, Salt Lake, Kolkata-700098 (India); Mazumdar, Chandan; Ranganathan, R [Experimental Condensed Matter Physics Division, Saha Institute of Nuclear Physics, 1/AF, Bidhannagar, Kolkata-700064 (India)], E-mail: abhishek.phy@gmail.com, E-mail: chandan.mazumar@saha.ac.in

    2009-05-27

    We report the change in the valency of Eu-ions in the binary intermetallic cubic compound EuPd{sub 3} induced by La doping at rare-earth sites. Doping of La generates negative chemical pressure in the lattice, resulting in a significant increase of the lattice parameter without altering the simple-cubic structure of the compound. Results of dc-magnetic measurements suggest that this increase in the lattice parameter is associated with the valence transition of Eu-ions from Eu{sup 3+} to a mixed-valent state. As Eu{sup 2+}-ions possess a large magnetic moment, this valence transition significantly modifies the magnetic behavior of the compound. In contrast to introducing boron at the vacant body center site of the unit cell to change the valency of Eu-ions, as in the case of EuPd{sub 3}B, our results suggest it can also be altered by doping a rare-earth ion of larger size at the lattice site of Eu in EuPd{sub 3}.

  11. Laparostomy management using the ABThera™ open abdomen negative pressure therapy system in a grade IV open abdomen secondary to acute pancreatitis.

    Science.gov (United States)

    Fitzgerald, James E F; Gupta, Shradha; Masterson, Sarah; Sigurdsson, Helgi H

    2013-04-01

    Wound control in laparostomy for the treatment of intra-abdominal hypertension remains challenging and numerous techniques have been described. We report the first UK experience with a new commercially available device specifically designed to facilitate management of the open abdomen. A 44-year-old gentleman presented with a 3-day history of constant severe epigastric pain and associated vomiting. Amylase was markedly elevated and he was admitted for supportive management of pancreatitis, with subsequent transfer to intensive care due to severe systemic inflammatory syndrome. The patient decompensated, developing intra-abdominal hypertension with renal and respiratory failure. This was successfully managed by performing a laparostomy and using an ABThera™ Open Abdomen Negative Pressure Therapy System (KCI, San Antonio, TX). We describe its use to facilitate wound control, including enteroatmospheric fistula, allowing granulation and eventual restoration of gastrointestinal continuity 383-days after admission. We found the ABThera™ System proved to be a useful treatment adjunct, protecting intra-abdominal contents while removing large volumes of exudate and infected material from within the abdominal cavity. Complex cases such as this remain infrequent and this article provides a summary of our experience, including a review of indications for laparostomy and the underlying basic science in this difficult area. © 2012 The Authors. International Wound Journal © 2012 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  12. Negative pressure wound therapy using a portable single-use device for free skin grafts on the distal extremity in seven dogs.

    Science.gov (United States)

    Miller, A J; Cashmore, R G; Marchevsky, A M; Havlicek, M; Brown, P M; Fearnside, S M

    2016-09-01

    Retrospective study to describe clinical experience with a portable single-use negative pressure wound therapy device after application of full-thickness meshed skin grafts to wounds on the distal extremities of seven dogs. Seven dogs were treated with portable NPWT after receiving skin grafts; six as the result of tumour resection and one for traumatic injury. Medical records were reviewed and data recorded on patient signalment, cause and location of wound, surgical technique, application and maintenance of portable NPWT, graft survival and outcome, and complications encountered with the system. NPWT was provided for between 4 and 7 days. Five patients were discharged from hospital during the treatment period. Application and maintenance of the portable device was technically easy and no major complications were encountered. Minor complications consisted of fluid accumulation in the evacuation tubing. All dogs achieved 100% graft survival. Application and maintenance of the portable device was technically straightforward. All dogs receiving portable NPWT after transfer of a free skin graft to the distal extremity had a successful outcome. © 2016 Australian Veterinary Association.

  13. Negative pressure wound therapy literature review of efficacy, cost effectiveness, and impact on patients' quality of life in chronic wound management and its implementation in the United kingdom.

    Science.gov (United States)

    Othman, Diaa

    2012-01-01

    This is a paper reviewing the National Health Service (NHS) agenda in relation to the use of Negative Pressure Wound Therapy (NPWT) in chronic wound management and assesses the evidence behind it, its cost effectiveness and the outcome it has on patients' satisfaction and life style. Multiple studies over the last 10 years looking at clinical efficacy of NPWT with its cost effectiveness and the implementation of this service in the UK were reviewed. NPWT has showed a reasonable body of evidence to support its usage in chronic wounds with potential positive outcomes on finance and patients' satisfaction. However, the NHS system shows significant variations in the availability and implementation of this useful tool, depending on care providers and resources availabilities. The paper concluded that the NPWT can be a useful source of cutting down costs of chronic wound managements and saving money by its effect on expediting wound healing, which can address a part of the financial crises facing the NHS, however, has to be considered according to specific case needs. There should also be a national standard for the availability and indication of this tool to assure equal opportunities for different patients in different areas in the country.

  14. A case of deep infection after instrumentation in dorsal spinal surgery: the management with antibiotics and negative wound pressure without removal of fixation.

    Science.gov (United States)

    Dobran, Mauro; Mancini, Fabrizio; Nasi, Davide; Scerrati, Massimo

    2017-07-28

    Until today the role of spinal instrumentation in the presence of a wound infection has been widely discussed and recently many authors leave the hardware in place with appropriate antibiotic therapy. This is a case of a 65-year-old woman suffering from degenerative scoliosis and osteoporotic multiple vertebral collapses treated with posterior dorsolumbar stabilisation with screws and rods. Four months later, skin necrosis and infection appeared in the cranial wound with exposure of the rods. A surgical procedure of debridement of the infected tissue and package with a myocutaneous trapezius muscle flap was performed. One week after surgery, negative pressure wound therapy was started on the residual skin defect. The wound healed after 2 months. The aim of this case report is to focus on the utility of this method even in the case of hardware exposure and infection. This may help avoid removing instrumentation and creating instability. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Ultra pressure liquid chromatography-negative electrospray ionization mass spectrometry determination of twelve halobenzoquinones at ng/L levels in drinking water.

    Science.gov (United States)

    Huang, Rongfu; Wang, Wei; Qian, Yichao; Boyd, Jessica M; Zhao, Yuli; Li, Xing-Fang

    2013-05-07

    We report here the characterization of twelve halobenzoquinones (HBQs) using electrospray ionization (ESI) high resolution quadrupole time-of-flight mass spectrometry. The high resolution negative ESI spectra of the twelve HBQs formed two parent ions, [M + H(+) + 2e(-)], and the radical M(-•). The intensities of these two parent ions are dependent on their chemical structures and on instrumental parameters such as the source temperature and flow rate. The characteristic ions of the HBQs were used to develop an ultra pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. At the UPLC flow rate (400 μL/min) and under the optimized ESI conditions, eleven HBQs showed the stable and abundant transitions [M + H(+) + 2e(-)] → X(-) (X(-) representing Cl(-), Br(-), or I(-)), while dibromo-dimethyl-benzoquinone (DBDMBQ) showed only the transition of M(-•) → Br(-). The UPLC efficiently separates all HBQs including some HBQ isomers, while the MS/MS offers exquisite limits of detection (LODs) at subng/mL levels for all HBQs except DBDMBQ. Combined with solid phase extraction (SPE), the method LOD is down to ng/L. The results from analysis of authentic samples demonstrated that the SPE-UPLC-MS/MS method is reliable, fast, and sensitive for the identification and quantification of the twelve HBQs in drinking water.

  16. Combing a novel device and negative pressure wound therapy for managing the wound around a colostomy in the open abdomen: A case report.

    Science.gov (United States)

    Sun, Xiaofang; Wu, Shaohan; Xie, Ting; Zhang, Jianping

    2017-12-01

    An open abdomen complicated with small-bowel fistulae becomes a complex wound for local infection, systemic sepsis and persistent soiling irritation by intestinal content. While controlling the fistulae drainage, protecting surrounding skin, healing the wound maybe a challenge. In this paper we described a 68-year-old female was admitted to emergency surgery in general surgery department with severe abdomen pain. Resection part of the injured small bowel, drainage of the intra-abdominal abscess, and fashioning of a colostomy were performed. She failed to improve and ultimately there was tenderness and lot of pus under the skin around the fistulae. The wound started as a 3-cm lesion and progressed to a 6 ×13  (78 cm) around the stoma. In our case we present a novel device for managing colostomy wound combination with negative pressure wound therapy. This tube allows for an effective drainage of small-bowel secretion and a safe build-up of granulation tissue. Also it could be a barrier between the bowel suction point and foam. Management of open abdomen wound involves initial dressing changes, antibiotic use and cutaneous closure. When compared with traditional dressing changes, the NPWT offers several advantages including increased granulation tissue formation, reduction in bacterial colonization, decreased of bowel edema and wound size, and enhanced neovascularization. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  17. Negative Pressure Wound Therapy Literature Review of Efficacy, Cost Effectiveness, and Impact on Patients' Quality of Life in Chronic Wound Management and Its Implementation in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Diaa Othman

    2012-01-01

    Full Text Available This is a paper reviewing the National Health Service (NHS agenda in relation to the use of Negative Pressure Wound Therapy (NPWT in chronic wound management and assesses the evidence behind it, its cost effectiveness and the outcome it has on patients’ satisfaction and life style. Multiple studies over the last 10 years looking at clinical efficacy of NPWT with its cost effectiveness and the implementation of this service in the UK were reviewed. NPWT has showed a reasonable body of evidence to support its usage in chronic wounds with potential positive outcomes on finance and patients’ satisfaction. However, the NHS system shows significant variations in the availability and implementation of this useful tool, depending on care providers and resources availabilities. The paper concluded that the NPWT can be a useful source of cutting down costs of chronic wound managements and saving money by its effect on expediting wound healing, which can address a part of the financial crises facing the NHS, however, has to be considered according to specific case needs. There should also be a national standard for the availability and indication of this tool to assure equal opportunities for different patients in different areas in the country.

  18. Antimicrobial-impregnated dressing combined with negative-pressure wound therapy increases split-thickness skin graft engraftment: a simple effective technique.

    Science.gov (United States)

    Wu, Cheng-Chun; Chew, Khong-Yik; Chen, Chien-Chang; Kuo, Yur-Ren

    2015-01-01

    Immobilization and adequate surface contact to wounds are critical for skin graft take. Techniques such as the tie-over dressing, cotton bolster, and vacuum-assisted closure are used to address this, but each has its limitations. This study is designed to assess the effect of antimicrobial-impregnated dressing (AMD) combined with negative-pressure wound therapy (NPWT) on skin graft survival. Retrospective case-control study : Patients with chronic or contaminated wounds treated with split-thickness skin graft. A broad spectrum of wounds was included, from causes such as trauma, burns, chronic diabetic ulcers, and infection. Antimicrobial-impregnated dressing, which contains 0.2% polyhexamethylene biguanide, with NPWT MAIN OUTCOME MEASURE:: Success of skin graft : In the AMD group, all skin grafts achieved 100% take without secondary intervention. No infection or graft failure was observed in any patients, and no complications, such as hematoma or seroma formation, were noted, although in the control group partial loss of skin grafts was noted in 3 patients. Infection and inadequate immobilization were thought to be the main reasons. There were no hematoma or seroma formations in the control group. Use of an AMD dressing with NPWT after split-thickness skin grafting can be an effective method to ensure good graft to wound contact and enhances skin graft take in chronic and contaminated wounds.

  19. The Effect of Negative Pressure Wound Therapy With Antiseptic Instillation on Biofilm Formation in a Porcine Model of Infected Spinal Instrumentation.

    Science.gov (United States)

    Singh, Devinder P; Gowda, Arvind U; Chopra, Karan; Tholen, Michael; Chang, Sarah; Mavrophilipos, Vasilios; Semsarzadeh, Nina; Rasko, Yvonne; Holton Iii, Luther

    2017-06-01

    This study evaluates the effect of negative pressure wound therapy with antiseptic instillation (NPWTi) in the clearance of infection and biofilm formation in an in vivo model of infected spinal implants compared to traditional treatment modalities. Five pigs underwent titanium rod implantation of their spinous processes followed by injection of 1 x 106 CFUs/100μL of methicillin-resistant Staphylococcus aureus through the fascia at each site. At 1 week postoperatively, an experimental arm of 3 pigs received NPWTi, and a control arm of 2 pigs received wet-to-dry dressings. The persistence of local infection in the experimental group was compared to the control group using tissue cultures. Biofilm development on spinal implants was evaluated using scanning electron microscopy. Mean bacterial count showed a statistical difference between the experimental and the control groups (P < .05). Scanning electron microscopy revealed the presence of uniform biofilm formation across the surface of control group instrumentation, whereas the experimental group showed interrupted areas between biofilm formations. The authors concluded that NPWTi is associated with decreased bacterial load and biofilm formation compared to wet-to-dry dressings in an in vivo porcine model of infected spinal instrumentation.

  20. Negative pressure wound therapy applied before and after split-thickness skin graft helps healing of Fournier gangrene: a case report (CARE-Compliant).

    Science.gov (United States)

    Ye, Junna; Xie, Ting; Wu, Minjie; Ni, Pengwen; Lu, Shuliang

    2015-02-01

    Fournier gangrene is a rare but highly infectious disease characterized by fulminant necrotizing fasciitis involving the genital and perineal regions. Negative pressure wound therapy (NPWT; KCI USA Inc, San Antonio, TX) is a widely adopted technique in many clinical settings. Nevertheless, its application and effect in the treatment of Fournier gangrene are unclear. A 47-year-old male patient was admitted with an anal abscess followed by a spread of the infection to the scrotum, which was caused by Pseudomonas aeruginosa. NPWT was applied on the surface of the scrotal area and continued for 10 days. A split-thickness skin graft from the scalp was then grafted to the wound, after which, NPWT utilizing gauze sealed with an occlusive dressing and connected to a wall suction was employed for 7 days to secure the skin graft. At discharge, the percentage of the grafted skin alive on the scrotum was 98%. The wound beside the anus had decreased to 4 × 0.5 cm with a depth of 1 cm. Follow-up at the clinic 1 month later showed that both wounds had healed. The patient did not complain of any pain or bleeding, and was satisfied with the outcome. NPWT before and after split-thickness skin grafts is safe, well tolerated, and efficacious in the treatment of Fournier gangrene.

  1. Effect of Negative Pressure Wound Therapy on Cellular Fibronectin and Transforming Growth Factor-β1 Expression in Diabetic Foot Wounds.

    Science.gov (United States)

    Yang, Shao Ling; Zhu, Lv Yun; Han, Rui; Sun, Lei Lei; Dou, Jing Tao

    2017-08-01

    Chronic diabetic foot wounds are a leading cause of amputation, morbidity, and hospitalization for patients with diabetes. Negative-pressure wound therapy (NPWT) can putatively facilitate wound healing, but the underlying mechanisms remain unclear. Cellular fibronectin (cFN) and transforming growth factor-β1 (TGF-β1) play an important role in wound healing. This prospective randomized controlled trial evaluated the effects of NPWT on the production of cFN and the expression of TGF-β1 in diabetic foot wounds of patients. From January 2012 to January 2015, 40 patients with diabetic foot wounds were randomly and equally apportioned to receive either NPWT or advanced moist wound therapy (control) for 7 days. Granulation tissue was harvested before and after treatment. Immunohistochemistry and Western blot were performed to evaluate protein levels of cFN and TGF-β1, and real-time polymerase chain reaction (PCR) to measure corresponding mRNA expressions. NPWT facilitated the expression of cFN and TGF-β1 in diabetic foot wounds. Immunohistochemical analysis revealed higher levels of cFN and TGF-β1 in the NPWT group than in the control group. Western blot and real-time PCR analysis further showed that protein and mRNA levels of cFN or TGF-β1 were higher in the NPWT group than that in the control group ( P diabetic foot ulcers. Level I, randomized controlled study.

  2. Visualization and void fraction measurement of decompressed boiling flow in a capillary tube

    International Nuclear Information System (INIS)

    Asano, H.; Murakawa, H.; Takenaka, N.; Takiguchi, K.; Okamoto, M.; Tsuchiya, T.; Kitaide, Y.; Maruyama, N.

    2011-01-01

    A capillary tube is often used as a throttle for a refrigerating cycle. Subcooled refrigerant usually flows from a condenser into the capillary tube. Then, the refrigerant is decompressed along the capillary tube. When the static pressure falls below the saturation pressure for the liquid temperature, spontaneous boiling occurs. A vapor-liquid two-phase mixture is discharged from the tube. In designing a capillary tube, it is necessary to calculate the flow rate for given boundary conditions on pressure and temperature at the inlet and exit. Since total pressure loss is dominated by frictional and acceleration losses during two-phase flow, it is first necessary to specify the boiling inception point. However, there will be a delay in boiling inception during decompressed flow. This study aimed to clarify the boiling inception point and two-phase flow characteristics of refrigerant in a capillary tube. Refrigerant flows in a coiled copper capillary tube were visualized by neutron radiography. The one-dimensional distribution of volumetric average void fraction was measured from radiographs through image processing. From the void fraction distribution, the boiling inception point was determined. Moreover, a simplified CT method was successfully applied to a radiograph for cross-sectional measurements. The experimental results show the flow pattern transition from intermittent flow to annular flow that occurred at a void fraction of about 0.45.

  3. 3D capillary valves for versatile capillary patterning of channel walls

    NARCIS (Netherlands)

    Papadimitriou, Vasileios; van den Berg, Albert; Eijkel, Jan C.T.

    2016-01-01

    We demonstrate passive capillary patterning of channel walls with a liquid in situ. Patterning is performed using a novel 3D capillary valve system combining three standard capillary stop valves. A range of different patterns is demonstrated in three channel walls. Capillary patterning was designed

  4. Capillary Condensation with a Grain of Salt.

    Science.gov (United States)

    Yarom, Michal; Marmur, Abraham

    2017-11-21

    Capillary condensation (CC), namely, the formation from the vapor of a stable phase of drops below the saturation pressure, is a prevalent phenomenon. It may occur inside porous structures or between surfaces of particles. CC between surfaces, a liquid "bridge", is of particular practical interest because of its resulting adhesive force. To date, studies have focused on pure water condensation. However, nonvolatile materials, such as salts and surfactants, are prevalent in many environments. In the current study, the effect of these contaminants on CC is investigated from a thermodynamic point of view. This is done by computing the Gibbs energy of such systems and developing the modified Kelvin equation, based on the Kohler theory. The results demonstrate that nonvolatile solutes may have a number of major effects, including an increase in the critical radius and the stabilization of the newly formed phase.

  5. A model for capillary rise in micro-tube restrained by a sticky layer

    Science.gov (United States)

    Shen, Anqi; Xu, Yun; Liu, Yikun; Cai, Bo; Liang, Shuang; Wang, Fengjiao

    2018-06-01

    Fluid transport in a microscopic capillary under the effects of a sticky layer was theoretically investigated. A model based on the classical Lucas-Washburn (LW) model is proposed for the meniscus rise with the sticky layer present. The sticky layer consists of two parts: a fixed (located at the wall) and a movable part (located on the inside of the capillary), affecting the micro-capillary flow in different ways. Within our model, the movable layer is defined by the capillary radius and pressure gradient. From the model it follows that the fixed sticky layer leads to a decrease of capillary radius, while the movable sticky layer increases flow resistance. The movable layer thickness varies with the pressure gradient, which in turn varies with the rising of the meniscus. The results of our theoretical calculation also prove that the capillary radius has a greater effect on the meniscus height, rather than the additional resistance caused by the movable layer. Moreover, the fixed sticky layer, which affects the capillary radius, has a greater influence than the movable sticky layer. We conclude that the sticky layer causes a lower imbibition height than the LW model predicts.

  6. Filling of charged cylindrical capillaries

    NARCIS (Netherlands)

    Das, Siddhartha; Chanda, Sourayon; Eijkel, J.C.T.; Tas, N.R.; Chakraborty, Suman; Mitra, Sushanta K.

    2014-01-01

    We provide an analytical model to describe the filling dynamics of horizontal cylindrical capillaries having charged walls. The presence of surface charge leads to two distinct effects: It leads to a retarding electrical force on the liquid column and also causes a reduced viscous drag force because

  7. Capillary thinning of polymeric filaments

    DEFF Research Database (Denmark)

    Kolte, Mette Irene; Szabo, Peter

    1999-01-01

    The capillary thinning of filaments of a Newtonian polybutene fluid and a viscoelastic polyisobutylene solution are analyzed experimentally and by means of numerical simulation. The experimental procedure is as follows. Initially, a liquid sample is placed between two cylindrical plates. Then, th...

  8. Vacuum scanning capillary photoemission microscopy.

    Science.gov (United States)

    Aseyev, S A; Cherkun, A P; Mironov, B N; Petrunin, V V; Chekalin, S V

    2017-08-01

    We demonstrate the use of a conical capillary in a scanning probe microscopy for surface analysis. The probe can measure photoemission from a substrate by transmitting photoelectrons along the capillary as a function of probe position. The technique is demonstrated on a model substrate consisting of a gold reflecting layer on a compact disc which has been illuminated by an unfocused laser beam with a wavelength 400nm, from a femtosecond laser with a beam size of 4mm. A quartz capillary with a 2-µm aperture has been used in the experiments. The period of gold microstructure, shown to be 1.6µ, was measured by the conical probe operating in shear force mode. In shear force regime, the dielectric capillary has been used as a "classical" SPM tip, which provided images reflecting the surface topology. In a photoelectron regime photoelectrons passed through hollow tip and entered a detector. The spatial distribution of the recorded photoelectrons consisted of periodic mountain-valley strips, resembling the surface profile of the sample. Submicron spatial resolution has been achieved. This approach paves the way to study pulsed photodesorption of large organic molecular ions with high spatial and element resolution using the combination of a hollow-tip scanner with time-of-flight technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Capillary Sharp Inner Edge Manufacturing

    Czech Academy of Sciences Publication Activity Database

    Hošek, Jan; Studenovský, K.; Najdek, D.

    2009-01-01

    Roč. 19, č. 35 (2009), s. 19-25 ISSN 1584-5982. [MECAHITECH 09 /1./. Bukurešť, 08.10.2009-09.10.2009] R&D Projects: GA AV ČR IAA200760905 Institutional research plan: CEZ:AV0Z20760514 Keywords : capillary * edge * manufacturing Subject RIV: JR - Other Machinery

  10. Influence of the inner diameters of capillary on the Z-Pinch plasma of the capillary discharge soft X-ray laser

    International Nuclear Information System (INIS)

    Jiang, Shan; Zhao, Yong-peng; Cui, Huai-yu; Li, Lian-bo; Ding, Yu-jie; Zhang, Wen-hong; Li, Wei

    2015-01-01

    In this paper, the effects of inner diameters on the Z-pinch plasma of capillary discharge soft X-ray laser were investigated with the 3.2 mm and 4.0 mm inner diameter alumina capillaries. The intensities of the laser emitted from the 3.2 mm and 4.0 mm inner diameter alumina capillaries were measured under different initial pressures. To understand the underlying physics of the experimental measurements, the Z-pinch plasma simulations had been conducted with a one-dimensional cylindrical symmetry Lagrangian magneto-hydrodynamics (MHD) code. The parametric studies of Z-pinch plasma, such as the electron temperature, the electron density and the Ne-like Ar ion density, were performed with the MHD code. With the experimental and the simulated results, the discussions had been conducted on the Z-pinch plasma of Ne-like Ar 46.9 nm laser with the 3.2 mm and 4.0 mm inner diameter alumina capillaries. The analysis had been made on the difference of the gain coefficients under the optimum pressures with both capillaries. Then, the effects of inner diameters on the optimum pressure and the pressure domain were analyzed. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. X-ray focusing using capillary arrays

    International Nuclear Information System (INIS)

    Nugent, K.A.; Chapman, H.N.

    1990-01-01

    A new form of X-ray focusing device based on glass capillary arrays is presented. Theoretical and experimental results for array of circular capillaries and theoretical and computational results for square hole capillaries are given. It is envisaged that devices such as these will find wide applications in X-ray optics as achromatic condensers and collimators. 3 refs., 4 figs

  12. Effect of air on water capillary flow in silica nanochannels

    DEFF Research Database (Denmark)

    Zambrano, Harvey; Walther, Jens Honore; Oyarzua, Elton

    2013-01-01

    , with the fabrication of microsystems integrated by nanochannels, a thorough understanding of the transport of fluids in nanoconfinement is required for a successful operation of the functional parts of such devices. In this work, Molecular Dynamics simulations are conducted to study the spontaneous imbibition of water...... in sub 10 nm silica channels. The capillary filling speed is computed in channels subjected to different air pressures. In order to describe the interactions between the species, an effective force field is developed, which is calibrated by reproducing the water contact angle. The results show...... that the capillary filling speed qualitatively follows the classical Washburn model, however, quantitatively it is lower than expected. Furthermore, it is observed that the deviations increase as air pressure is higher. We attribute the deviations to amounts of air trapped at the silica-water interface which leads...

  13. Fabrication and modeling of narrow capillaries for vacuum system gas inlets

    DEFF Research Database (Denmark)

    Quaade, Ulrich; Jensen, Søren; Hansen, Ole

    2005-01-01

    Micrometer-sized cylindrical capillaries with well-controlled dimensions are fabricated using deep reactive ion etching. The flow through the capillaries is experimentally characterized for varying pressures, temperatures, and diameters. For the parameters used, it is shown that the Knudsen numbe...... is in the intermediate flow regime, and Knudsen's expression for the flow fit the data well. The flow properties of the capillaries make them ideal for introducing gas into vacuum systems and in particular mass spectrometers. ©2005 American Institute of Physics...

  14. Theoretical investigation of adiabatic capillary tubes working with propane/n-butane/iso-butane blends

    International Nuclear Information System (INIS)

    Fatouh, M.

    2007-01-01

    In this paper, a theoretical model is developed to predict the refrigerant flow characteristics in adiabatic capillary tubes using propane/n-butane/iso-butane mixtures as working fluids in a domestic refrigerator. This model is based on the mass, energy and momentum conservation equations for a homogeneous refrigerant flow under different inlet conditions, such as subcooled, saturated and two phase flow. The effects of the inlet pressure (8-16 bar), inlet vapor quality (0.001-15%), inlet subcooling degree (1-15 o C), mass flow rate (1-5 kg/h), propane mass fraction (0.5-0.7), capillary tube inner diameter (0.6-1.0 mm) and the tube surface roughness on the capillary tube length are predicted. The results showed that the present model predicts data that are very close to the available experimental data in the literature with an average error of 2.65%. The pressure of the hydrocarbon mixture (HCM) decreases, while its vapor quality, specific volume and Mach number increase along the capillary tube. Also, the results indicated that the capillary tube length is largely dependent on the capillary tube diameter. Other parameters such as mass flow rate, inlet pressure, subcooling degree (or quality) and relative roughness influence the capillary tube length in that order. The capillary tube length as a function of the significant parameters is presented in equation form. Also, capillary tube selection charts either to predict the mass flow rates of propane/n-butane/iso-butane mixtures through adiabatic capillary tubes or to select the capillary tube size according to the required applications are developed. The comparison between R12, R134a and the hydrocarbon mixture (HCM) of propane/n-butane/iso-butane indicated that for a given mass flow rate, the pressure drop per unit length is about 4.13, 5.0 and 12.0 bar/m for R12, R134a and HCM, respectively. The ratios of the average mass flow rate of the HCM with a propane mass fraction of 0.6 to those of R12 and R134a are about

  15. Inactivation of gram-negative bacteria in milk and banana juice by hen egg white and lambda lysozyme under high hydrostatic pressure.

    Science.gov (United States)

    Nakimbugwe, Dorothy; Masschalck, Barbara; Anim, Grace; Michiels, Chris W

    2006-10-15

    The effect of hen egg white lysozyme (HEWL) and bacteriophage lambda lysozyme (LaL) in combination with high pressure (HP) treatment on the inactivation of four gram-negative bacteria (Escherichia coli O157:H7, Shigella flexneri, Yersinia enterocolitica and Salmonella typhimurium), was studied in skim milk (pH 6.8; a(w) 0.997) and in banana juice (pH 3.8; a(w) 0.971). In the absence of lysozymes, S. flexneri was more sensitive to HP in milk than in banana juice, while the opposite was observed for the other three bacteria. In combination with HP treatment, LaL was more effective than HEWL on all bacteria in both milk and banana juice. Depending on the bacteria, inactivation levels in banana juice were increased from 0.4-2.7 log units by HP treatment alone to 3.6-6.5 log units in the presence of 224 U/ml LaL. Bacterial inactivation in milk was also enhanced by LaL but only by 0.5-2.1 log units. Under the experimental conditions used, LaL was more effective in banana juice than in milk, while the effectiveness of HEWL under the same conditions was not significantly affected by the food matrix. This effect could be ascribed to the low pH of the banana juice since LaL was also more effective on E. coli in buffer at pH 3.8 than at pH 6.8. Since neither LaL nor HEWL are enzymatically active at pH 3.8, we analysed bacterial lysis after HP treatment in the presence of these enzymes, and found that inactivation proceeds through a non-lytic mechanism at pH 3.8 and a lytic mechanism at pH 6.8. Based on these results, LaL may offer interesting perspectives for use as an extra hurdle in high pressure food preservation.

  16. Negative Pressure Wound Therapy With Instillation (NPWTi) Better Reduces Post-debridement Bioburden in Chronically Infected Lower Extremity Wounds Than NPWT Alone.

    Science.gov (United States)

    Goss, S G; Schwartz, J A; Facchin, F; Avdagic, E; Gendics, C; Lantis, J C

    2012-12-01

    An overabundance of bacteria in the chronic wound plays a significant role in the decreased ability for primary closure. One means of decreasing the bioburden in a wound is to operatively debride the wound for wound bed optimization prior to application of other therapy, such as Negative Pressure Wound Therapy (NPWT). We undertook a prospective pilot study to assess the efficacy of wound bed preparation for a standard algorithm (sharp surgical debridement followed by NPWT) versus one employing sharp surgical debridement followed by Negative Pressure Wound Therapy with Instillation (NPWTi). Thirteen patients, corresponding to 16 chronic lower leg and foot wounds were taken to the operating room for debridement. The patients were sequentially enrolled in 2 treatment groups: the first receiving treatment with operative debridement followed by 1 week of NPWT with the instillation of quarter strength bleach solution; the other receiving a standard algorithm consisting of operative debridement and 1 week of NPWT. Quantitative cultures were taken pre-operatively after sterile preparation and draping of the wound site (POD # 0, pre-op), post-operatively once debridement was completed (POD # 0, post-op), and on post-operative day 7 after operative debridement (POD # 7, post-op). After operative debridement (post-operative day 0) there was a mean of 3 (±1) types of bacteria per wound. The mean CFU/gram tissue culture was statistically greater - 3.7 × 10(6) (±4 × 10(6)) in the NPWTi group, while in the standard group (NPWT) the mean was 1.8 × 10(6) (±2.36 × 10(6)) CFU/gram tissue culture (p = 0.016); at the end of therapy there was no statistical difference between the two groups (p = 0.44). Wounds treated with NPWTi had a mean of 2.6 × 10(5) (±3 × 10(5)) CFU/gram of tissue culture while wounds treated with NPWT had a mean of 2.79 × 10(6) (±3.18 × 10(6)) CFU/gram of tissue culture (p = 0.43). The mean absolute reduction in bacteria for the

  17. Comparison of Negative Pressure Wound Therapy Using Vacuum-Assisted Closure with Advanced Moist Wound Therapy in the Treatment of Diabetic Foot Ulcers.

    Science.gov (United States)

    Sajid, Muhammad Tanveer; Mustafa, Qurat ul Ain; Shaheen, Neelofar; Hussain, Syed Mukarram; Shukr, Irfan; Ahmed, Muhammad

    2015-11-01

    To evaluate the clinical efficacy of Negative Pressure Wound Therapy (NPWT) using Vacuum Assisted Closure (VAC) compared with Advanced Moist Wound Therapy (AMWT) to treat Diabetic Foot Ulcer (DFU). Randomized control trial. Surgical Department, Combined Military Hospital (CMH) / Military Hospital (MH), Rawalpindi, from November 2010 to June 2012. The study consisted of 278 patients, with 139 patients each in Group 'A' and 'B', who were subjected to AMWT and NPWT, respectively. Wound was assessed digitally every week for 2 weeks. Wound dimension and surface area were determined using University of Texas Health Centre at San Antonio (UTHCSA) image tool version 3.0. Efficacies of AMWT and NPWT were compared in terms of reduction in wound area over 2 weeks. Mean age of presentation in group A was 55.88 ± 10.97 years while in group B, it was 56.83 ± 11.3 (p=0.48). Mean duration of diabetes at presentation was 15.65 ± 4.86 and 15.96 ± 5.79 years in group A and B, respectively (p=0.74). Majority of patients had Wagner's grade 2 ulcer (82% in group A and 87.8% in group B, p= 0.18). Initial wound size in group A was 15.07 ± 2.92 cm2 and in group B 15.09 ± 2.81 cm2 (p = 0.95). Wound size measured after 2 weeks, treatment was in group A13.70 ± 2.92 cm2 and in group B 11.53 ± 2.78 cm2 (p VAC was more efficacious than AMWT in the management of diabetic foot ulcers.

  18. Health Technology Assessment of the Negative Pressure Wound Therapy for the treatment of acute and chronic wounds: efficacy, safety, cost effectiveness, organizational and ethical impact

    Directory of Open Access Journals (Sweden)

    Paolo Giorgi Rossi

    2012-06-01

    Full Text Available

    Background: the aim of the study was to assess the safety, efficacy and cost-effectiveness of negative Pressure wound therapy (nPT for people with chronic and acute wounds.

    Methods: the scope and the final draft of the report have been submitted to the stakeholders (producers, payers and patients. safety issues were addressed through a systematic review of the meta-literature. efficacy was addressed through a systematic review and meta-analysis of randomized controlled trials (rcTs comparing nPT and other standard therapies in patients with chronic or acute lesions. cost-consequence was analyzed through a systematic review of the existing studies.

    Results: we retrieved 19 studies, 13 of which were included in the meta-analysis. Many studies had biases that may have resulted in a better performance for nPT. nPT showed: a slightly shorter healing time (-10.4 days, p=0.001, with no heterogeneity, apart from one small study with very positive results, and 40% more patients healed (p=0.002, no heterogeneity.We identified 15 original research papers on nPT costs and cost per outcome. The costs-per-patient- treated varied from +29% to -60%, with several studies reporting savings for nPT.

    Conclusions: despite serious methodological flaws, the body of evidence available was sufficient to prove some clinical benefit of nPT in severe chronic and acute wound treatment. There is a need for independent and contextualized cost analyses....

  19. Negative pressure wound therapy, staged excision and definitive closure with split-thickness skin graft for axillary hidradenitis suppurativa: a retrospective study.

    Science.gov (United States)

    Pearce, F B; Richardson, K A

    2017-01-02

    Bilateral axillary hidradenitis is a chronic, suppurative, and scarring disease that is most effectively treated by complete excision of all hair-bearing tissues. We assessed our staged procedure for excision and placement of a split-thickness skin graft for bilateral axillary hidradenitis in terms of costs, outcomes, and timing of excision. An IRB approved retrospective case analysis was performed on patients that underwent bilateral axillary hidradenitis skin excision with eventual placement of split-thickness skin grafting using the current LSUHSC/University Health hidradenitis surgical treatment protocol. Using ICD-9 codes (705.83) and CPT codes (11041, 11042, 11451, 11600, 11601, 11602, 11603, 11604) we reviewed cases performed at our institution from 1 January 2008 to 24 Febuary 2014 and we selected patients based on bilateral axillary involvement (alone) and >1 year history of active disease. Patients were excluded if resection of tissue encompassed regions outside of the immediately adjacent axillary. A total of seven patients matching criteria for bilateral axillary hidradenitis were selected for analysis. Clinical course, cost and surgical techniques were assessed. Of the seven patients, six required admission throughout their treatment due to lack of funding making use of negative pressure wound therapy at home not possible. These patients stayed an average of 10 days with a mean hospital charge of $35,178 and a mean hospital provider charge of $10,019. No recurrence was demonstrated. All patients attained full range of motion, post grafting. No patient required a further operation due to graft failure. Split-thickness skin grafting without use of bilayer dermal regenerative templates yielded definitive results with acceptable cosmesis and functionality, without the added cost of treatments such as a bilayer dermal regenerative template.

  20. Comparison of negative pressure wound therapy using vacuum-assisted closure with advanced moist wound therapy in the treatment of diabetic foot ulcers

    International Nuclear Information System (INIS)

    Sajid, M.T.; Mustafa, Q.U.A.

    2015-01-01

    Objective: To evaluate the clinical efficacy of Negative Pressure Wound Therapy (NPWT) using Vacuum Assisted Closure (VAC) compared with Advanced Moist Wound Therapy (AMWT) to treat Diabetic Foot Ulcer (DFU). Study Design: Randomized control trial. Place and Duration of Study: Surgical Department, Combined Military Hospital (CMH) / Military Hospital (MH), Rawalpindi, from November 2010 to June 2012. Methodology: The study consisted of 278 patients, with 139 patients each in Group A and B, who were subjected to AMWT and NPWT, respectively. Wound was assessed digitally every week for 2 weeks. Wound dimension and surface area were determined using University of Texas Health Centre at San Antonio (UTHCSA) image tool version 3.0. Efficacies of AMWT and NPWT were compared in terms of reduction in wound area over 2 weeks. Results: Mean age of presentation in group Awas 55.88 10.97 years while in group B, it was 56.83 ± 11.3 (p=0.48). Mean duration of diabetes at presentation was 15.65 ± 4.86 and 15.96 ± 5.79 years in group A and B, respectively (p=0.74). Majority of patients had Wagner's grade 2 ulcer (82% in group A and 87.8% in group B, p= 0.18). Initial wound size in group A was 15.07 ± 2.92 cm2and in group B 15.09 ± 2.81 cm2(p = 0.95). Wound size measured after 2 weeks, treatment was in group A13.70 ± 2.92 cm2 and in group B 11.53 ± 2.78 cm2 (p < 0.001). Wound area reduction in both groups revealed statistically significant faster healing in group B as compared to group A(p < 0.001). Conclusion: NPWT using VAC was more efficacious than AMWT in the management of diabetic foot ulcers. (author)

  1. Use of collagenase ointment in conjunction with negative pressure wound therapy in the care of diabetic wounds: a case series of six patients

    Directory of Open Access Journals (Sweden)

    John D. Miller

    2015-01-01

    Full Text Available Background: Diabetic wounds with additional comorbidities are costly, time intensive, and difficult to heal. Often, multiple modalities may be necessary to achieve wound resolution, relying on the synergistic advantage of each therapy to affect wound healing. The selectivity of Clostridium collagenase is physiologically effective at degrading non-viable collagen fibers while preserving living collagen tissue. Additionally, negative pressure wound therapy (NPWT has long been used to aid wound healing while concurrently depreciating biological wound burden time. Methods: Six patients were selected from those appearing to our university based limb salvage service. Inclusion criteria included patients with a recurrent mixed fibrotic and granular wound base, in which NPWT was indicated, without exclusion criteria. Patients enrolled were administered clostridial collagenase ointment at each regularly scheduled NPWT dressing change. Patients were followed until healing, with visual representations of wound progression and time to full healing recorded. Results: Tandem application of these therapies appeared to expedite wound healing by clearing degenerative fibrous tissue and expediting wound granulation without additional complication. Unfortunately, not all patients were able to reach full healing; with two patients experiencing ulcer recurrence, likely a result of their significant comorbid nature. Conclusion: In our experience, we have noticed a specific subgroup of patients who benefit greatly when collagenase enzymatic debridement therapy is combined with NPWT. It is our belief that this combination therapy combines the molecular clearing of non-viable collagen with the wound granulation necessary to advance complex wounds to the next step in healing despite the current paucity in literature discussing this specific pairing.

  2. Basal electric and magnetic fields of celestial bodies come from positive-negative charge separation caused by gravitation of quasi-Casimir pressure in weak interaction

    Science.gov (United States)

    Chen, Shao-Guang

    According to f =d(mv)/dt=m(dv/dt)+ v(dm/dt), a same gravitational formula had been de-duced from the variance in physical mass of QFT and from the variance in mass of inductive energy-transfer of GR respectively: f QF T = f GR = -G (mM/r2 )((r/r)+(v/c)) when their interaction-constants are all taken the experimental values (H05-0029-08, E15-0039-08). f QF T is the quasi-Casimir pressure. f GR is equivalent to Einstein's equation, then more easy to solve it. The hypothesis of the equivalent principle is not used in f QF T , but required by f GR . The predictions of f QF T and f GR are identical except that f QF T has quantum effects but f GR has not and f GR has Lense-Thirring effect but f QF T has not. The quantum effects of gravitation had been verified by Nesvizhevsky et al with the ultracold neutrons falling in the earth's gravitational field in 2002. Yet Lense-Thirring effect had not been measured by GP-B. It shows that f QF T is essential but f GR is phenomenological. The macro-f QF T is the statistic average pressure collided by net virtual neutrinos ν 0 flux (after self-offset in opposite directions) and in direct proportion to the mass. But micro-f QF T is in direct proportion to the scattering section. The electric mass (in inverse proportion to de Broglie wavelength λ) far less than nucleonic mass and the electric scattering section (in direct proportion to λ2 ) far large than that of nucleon, then the net ν 0 flux pressure exerted to electron far large than that to nucleon and the electric displacement far large than that of nucleon, it causes the gravitational polarization of positive-negative charge center separation. Because the gravity far less than the electromagnetic binding force, in atoms the gravitational polarization only produces a little separation. But the net ν 0 flux can press a part freedom electrons in plasma of ionosphere into the earth's surface, the static electric force of redundant positive ions prevents electrons from further

  3. Pressure cryocooling protein crystals

    Science.gov (United States)

    Kim, Chae Un [Ithaca, NY; Gruner, Sol M [Ithaca, NY

    2011-10-04

    Preparation of cryocooled protein crystal is provided by use of helium pressurizing and cryocooling to obtain cryocooled protein crystal allowing collection of high resolution data and by heavier noble gas (krypton or xenon) binding followed by helium pressurizing and cryocooling to obtain cryocooled protein crystal for collection of high resolution data and SAD phasing simultaneously. The helium pressurizing is carried out on crystal coated to prevent dehydration or on crystal grown in aqueous solution in a capillary.

  4. Hysteresis of the Contact Angle of a Meniscus Inside a Capillary with Smooth, Homogeneous Solid Walls.

    Science.gov (United States)

    Kuchin, Igor V; Starov, Victor M

    2016-05-31

    A theory of contact angle hysteresis of a meniscus inside thin capillaries with smooth, homogeneous solid walls is developed in terms of surface forces (disjoining/conjoining pressure isotherm) using a quasi-equilibrium approach. The disjoining/conjoining pressure isotherm includes electrostatic, intermolecular, and structural components. The values of the static receding θr, advancing θa, and equilibrium θe contact angles in thin capillaries were calculated on the basis of the shape of the disjoining/conjoining pressure isotherm. It was shown that both advancing and receding contact angles depend on the capillary radius. The suggested mechanism of the contact angle hysteresis has a direct experimental confirmation: the process of receding is accompanied by the formation of thick β-films on the capillary walls. The effect of the transition from partial to complete wetting in thin capillaries is predicted and analyzed. This effect takes place in very thin capillaries, when the receding contact angle decreases to zero.

  5. Capillary/myocyte mismatch in the heart in renal failure--a role for erythropoietin?

    Science.gov (United States)

    Amann, K; Buzello, M; Simonaviciene, A; Miltenberger-Miltenyi, G; Koch, A; Nabokov, A; Gross, M L; Gless, B; Mall, G; Ritz, E

    2000-07-01

    Chronic renal failure is characterized by remodeling of the heart with left ventricular hypertrophy (increasing oxygen demand) and capillary deficit leading to capillary/myocyte mismatch (decreasing oxygen supply). Erythropoietin (Epo) has known angiogenic properties causing endothelial cell activation, migration and sprouting, mediated at least in part via the JAK/STAT (Janus kinase/signal transducers and activators of transcription) pathway. In uraemic cardiac hypertrophy the presence of diminished capillary supply implies that capillary growth does not keep pace with development of hypertrophy. To investigate whether this was due to a deficit of the angiogenic hormone Epo we examined whether Epo levels are altered and whether an increase in haematocrit by administration of rhEpo influences capillary supply, i.e. capillary/myocyte mismatch in experimental renal failure. Male Spraque-Dawley rats were either subjected to partial renal ablation or sham operation. Only modest amounts of renal tissue were removed so that the rats were not anemic. Subgroups of rats received either human (rh)Epo alone or in combination with unspecific antihypertensive treatment (dihydralazine plus furosemide) in order to control the Epo induced rise in blood pressure. Capillary supply was measured stereologically as capillary length per volume myocardium using the orientator method. Capillary length density was reduced by approximately 25% after partial renal ablation (3237+/-601 vs 4293+/-501 mm/mm(3) in controls). It was not statistically different in animals with partial renal ablation+rhEpo+antihypertensive treatment (3620+/-828 mm/mm(3)) compared to partial ablation alone. The study shows that lack of Epo does not cause, or contribute to, the deficit of capillary growth in the hypertrophied left ventricle of rats with renal failure. In addition, a rise in haematocrit is not accompanied by beneficial effects on alterations of cardiovascular structure in experimental renal failure.

  6. Capillary waves with surface viscosity

    Science.gov (United States)

    Shen, Li; Denner, Fabian; Morgan, Neal; van Wachem, Berend; Dini, Daniele

    2017-11-01

    Experiments over the last 50 years have suggested a correlation between the surface (shear) viscosity and the stability of a foam or emulsion. With recent techniques allowing more accurate measurements of the elusive surface viscosity, we examine this link theoretically using small-amplitude capillary waves in the presence of the Marangoni effect and surface viscosity modelled via the Boussinesq-Scriven model. The surface viscosity effect is found to contribute a damping effect on the amplitude of the capillary wave with subtle differences to the effect of the convective-diffusive Marangoni transport. The general wave dispersion is augmented to take into account the Marangoni and surface viscosity effects, and a first-order correction to the critical damping wavelength is derived. The authors acknowledge the financial support of the Shell University Technology Centre for fuels and lubricants.

  7. Negative pressure wound treatment improves Acute Physiology and Chronic Health Evaluation II score in mediastinitis allowing a successful elective pectoralis muscle flap closure: six-year experience of a single protocol.

    Science.gov (United States)

    Salica, Andrea; Weltert, Luca; Scaffa, Raffaele; Guerrieri Wolf, Lorenzo; Nardella, Saverio; Bellisario, Alessandro; De Paulis, Ruggero

    2014-11-01

    Optimal management of poststernotomy mediastinitis is controversial. Negative pressure wound treatment improves wound environment and sternal stability with low surgical invasiveness. Our protocol was based on negative pressure followed by delayed surgical closure. The aim of this study was to provide the results at early follow-up and to identify the risk factors for adverse outcome. In 5400 cardiac procedures, 44 consecutive patients with mediastinitis were enrolled in the study. Mediastinitis treatment was based on urgent debridement and negative pressure as the first-line approach. After wound sterilization, chest closure was achieved by elective pectoralis muscle advancement flap. Each patient's hospital data were collected prospectively. Variables included patient demographics and clinical and biological data. Acute Physiology and Chronic Health Evaluation (APACHE) II score was calculated at the time of diagnosis and 48 hours after debridement. Focus outcome measures were mediastinitis-related death and need for reintervention after pectoralis muscle closure. El Oakley type I and type IIIA mediastinitis were the most frequent types (63.6%). Methicillin-resistant Staphylococcus aureus was present in 25 patients (56.8%). Mean APACHE II score was 19.4±4 at the time of diagnosis, and 30 patients (68.2%) required intensive care unit transfer before surgical debridement. APACHE II score improved 48 hours after wound debridement and negative pressure application (mean value, 19.4±4 vs 7.2±2; P=.005) independently of any other variables included in the study. One patient in septic shock at the time of diagnosis died (2.2%). Negative pressure promotes a significant improvement in clinical status according to APACHE II score and allows a successful elective surgical closure. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  8. Capillary Refill using Augmented Reality

    OpenAIRE

    Clausen, Christoffer

    2017-01-01

    Master's thesis in Computer science The opportunities within augmented reality is growing. Augmented reality is a combination of the real and the virtual world in real time, and large companies like Microsoft and Google is now investing heavily in the technology. This thesis presents a solution for simulating a medical test called capillary refill, by using augmented reality. The simulation is performed with an augmented reality headset called HoloLens. The HoloLens will recognise a mark...

  9. Capillary electrophoresis systems and methods

    Science.gov (United States)

    Dorairaj, Rathissh [Hillsboro, OR; Keynton, Robert S [Louisville, KY; Roussel, Thomas J [Louisville, KY; Crain, Mark M [Georgetown, IN; Jackson, Douglas J [New Albany, IN; Walsh, Kevin M [Louisville, KY; Naber, John F [Goshen, KY; Baldwin, Richard P [Louisville, KY; Franco, Danielle B [Mount Washington, KY

    2011-08-02

    An embodiment of the invention is directed to a capillary electrophoresis apparatus comprising a plurality of separation micro-channels. A sample loading channel communicates with each of the plurality of separation channels. A driver circuit comprising a plurality of electrodes is configured to induce an electric field across each of the plurality of separation channels sufficient to cause analytes in the samples to migrate along each of the channels. The system further comprises a plurality of detectors configured to detect the analytes.

  10. Capillaries modified by noncovalent anionic polymer adsorption for capillary zone electrophoresis, micellar electrokinetic capillary chromatography and capillary electrophoresis mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L; Hansen, S H; Gammelgaard, Bente

    2001-01-01

    A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene...... capillaries was (4.9+/-0.1) x 10(-4) cm2V(-1)s(-1) in a pH-range of 2-10 (ionic strength = 30 mM). When alkaline compounds were used as test substances intracapillary and intercapillary migration time variations (n = 6) were less than 1% relative standard deviation (RSD) and 2% RSD, respectively in the entire...... pH range. The coating was fairly stable in the presence of sodium dodecyl sulfate, and this made it possible to perform fast MEKC separations at low pH. When neutral compounds were used as test substances, the intracapillary migration time variations (n = 6) were less than 2% RSD in a pH range of 2...

  11. Novel insights into nanopore deformation caused by capillary condensation.

    Science.gov (United States)

    Günther, Gerrit; Prass, Johannes; Paris, Oskar; Schoen, Martin

    2008-08-22

    By means of in situ small-angle x-ray diffraction experiments and semi-grand-canonical ensemble Monte Carlo simulations we demonstrate that sorption and condensation of a fluid confined within nanopores is capable of deforming the pore walls. At low pressures the pore is widened due to a repulsive interaction caused by collisions of the fluid molecules with the walls. At capillary condensation the pores contract abruptly on account of attractive fluid-wall interactions whereas for larger pressures they expand again. These features cannot solely be accounted for by effects related to pore-wall curvature but have to be attributed to fluid-wall dispersion forces instead.

  12. Experimental evidence for negative turgor pressure in small leaf cells of Robinia pseudoacacia L versus large cells of Metasequoia glyptostroboides Hu et W.C. Cheng. 2. Höfler diagrams below the volume of zero turgor and the theoretical implication for pressure-volume curves of living cells.

    Science.gov (United States)

    Yang, Dongmei; Li, Junhui; Ding, Yiting; Tyree, Melvin T

    2017-03-01

    The physiological advantages of negative turgor pressure, P t , in leaf cells are water saving and homeostasis of reactants. This paper advances methods for detecting the occurrence of negative P t in leaves. Biomechanical models of pressure-volume (PV) curves predict that negative P t does not change the linearity of PV curve plots of inverse balance pressure, P B , versus relative water loss, but it does predict changes in either the y-intercept or the x-intercept of the plots depending on where cell collapse occurs in the P B domain because of negative P t . PV curve analysis of Robinia leaves revealed a shift in the x-intercept (x-axis is relative water loss) of PV curves, caused by negative P t of palisade cells. The low x-intercept of the PV curve was explained by the non-collapse of palisade cells in Robinia in the P B domain. Non-collapse means that P t smoothly falls from positive to negative values with decreasing cell volume without a dramatic change in slope. The magnitude of negative turgor in non-collapsing living cells was as low as -1.3 MPa and the relative volume of the non-collapsing cell equaled 58% of the total leaf cell volume. This study adds to the growing evidence for negative P t . © 2016 John Wiley & Sons Ltd.

  13. High pressure studies of A2Mo3O12 negative thermal expansion materials (A2=Al2, Fe2, FeAl, AlGa)

    International Nuclear Information System (INIS)

    Young, Lindsay; Gadient, Jennifer; Gao, Xiaodong; Lind, Cora

    2016-01-01

    High pressure powder X-ray diffraction studies of several A 2 Mo 3 O 12 materials (A 2 =Al 2 , Fe 2 , FeAl, and AlGa) were conducted up to 6–7 GPa. All materials adopted a monoclinic structure under ambient conditions, and displayed similar phase transition behavior upon compression. The initial isotropic compressibility first became anisotropic, followed by a small but distinct drop in cell volume. These patterns could be described by a distorted variant of the ambient pressure polymorph. At higher pressures, a distinct high pressure phase formed. Indexing results confirmed that all materials adopted the same high pressure phase. All changes were reversible on decompression, although some hysteresis was observed. The similarity of the high pressure cells to previously reported Ga 2 Mo 3 O 12 suggested that this material undergoes the same sequence of transitions as all materials investigated in this paper. It was found that the transition pressures for all phase changes increased with decreasing radius of the A-site cations. - Graphical abstract: Overlay of variable pressure X-ray diffraction data of Al 2 Mo 3 O 12 collected in a diamond anvil cell. Both subtle and discontinuous phase transitions are clearly observed. - Highlights: • The high pressure behavior of A 2 Mo 3 O 12 (A=Al, Fe, (AlGa), (AlFe)) was studied. • All compounds undergo the same sequence of pressure-induced phase transitions. • The phase transition pressures correlate with the average size of the A-site cation. • All transitions were reversible with hysteresis. • Previously studied Ga 2 Mo 3 O 12 undergoes the same sequence of transitions.

  14. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  15. An Apparent Deficiency of Lymphatic Capillaries in the Islets of Langerhans in the Human Pancreas.

    Science.gov (United States)

    Korsgren, Erik; Korsgren, Olle

    2016-04-01

    The lymphatic system is crucial for efficient immune surveillance and for the maintenance of a physiological pressure in the interstitial space. Even so, almost no information is available concerning the lymph drainage of the islets of Langerhans in the human pancreas. Immunohistochemical staining allowed us to distinguish lymphatic capillaries from blood capillaries. Almost no lymphatic capillaries were found within the islets in pancreatic biopsy specimens from subjects without diabetes or from subjects with type 1 or type 2 diabetes. Lymphatic capillaries were, however, found at the islet-exocrine interface, frequently located along blood capillaries and other fibrotic structures within or close to the islet capsule. Lymphatic capillaries were regularly found in the exocrine pancreas, with small lymphatic vessels located close to and around acini. Larger collecting lymphatic vessels were located in fibrotic septa between the exocrine lobules and adjacent to the ductal system of the pancreas. In summary, we report a pronounced deficiency of lymphatic capillaries in human islets, a finding with implications for immune surveillance and the regulation of interstitial fluid transport in the endocrine pancreas as well as for the pathophysiology of both type 1 and type 2 diabetes. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  16. A low-cost, manufacturable method for fabricating capillary and optical fiber interconnects for microfluidic devices.

    Science.gov (United States)

    Hartmann, Daniel M; Nevill, J Tanner; Pettigrew, Kenneth I; Votaw, Gregory; Kung, Pang-Jen; Crenshaw, Hugh C

    2008-04-01

    Microfluidic chips require connections to larger macroscopic components, such as light sources, light detectors, and reagent reservoirs. In this article, we present novel methods for integrating capillaries, optical fibers, and wires with the channels of microfluidic chips. The method consists of forming planar interconnect channels in microfluidic chips and inserting capillaries, optical fibers, or wires into these channels. UV light is manually directed onto the ends of the interconnects using a microscope. UV-curable glue is then allowed to wick to the end of the capillaries, fibers, or wires, where it is cured to form rigid, liquid-tight connections. In a variant of this technique, used with light-guiding capillaries and optical fibers, the UV light is directed into the capillaries or fibers, and the UV-glue is cured by the cone of light emerging from the end of each capillary or fiber. This technique is fully self-aligned, greatly improves both the quality and the manufacturability of the interconnects, and has the potential to enable the fabrication of interconnects in a fully automated fashion. Using these methods, including a semi-automated implementation of the second technique, over 10,000 interconnects have been formed in almost 2000 microfluidic chips made of a variety of rigid materials. The resulting interconnects withstand pressures up to at least 800psi, have unswept volumes estimated to be less than 10 femtoliters, and have dead volumes defined only by the length of the capillary.

  17. Influence of the capillary on the ignition of the transient spark discharge

    International Nuclear Information System (INIS)

    Gerling, T; Hoder, T; Brandenburg, R; Bussiahn, R; Weltmann, K-D

    2013-01-01

    A self-pulsing negative dc discharge in argon generated in a needle-to-plane geometry at open atmosphere is investigated. Additionally, the needle electrode can be surrounded by a quartz capillary. It is shown that the relative position of the capillary end to the needle tip strongly influences the discharge inception and its spatio-temporal dynamics. Without the capillary for the selected working parameters a streamer corona is ignited, but when the capillary surrounds the needle, the transient spark (TS) discharge is ignited after a pre-streamer (PS) occurs. The time between PS and TS discharge depends on the relative capillary end position. The existence of the PS is confirmed by electro-optical characterization. Furthermore, spectrally and spatio-temporally resolved cross-correlation spectroscopy is applied to show the most active region of pre-phase emission activity as indicators for high local electric field strength. The results indicate that with a capillary in place, the necessary energy input of the pre-phase into the system is mainly reduced by additional electrical fields at the capillary edge. Even such a small change as a shift of dielectric surface close to the plasma largely changes the energy balance in the system. (paper)

  18. High-Throughput Proteomics Using High Efficiency Multiple-Capillary Liquid Chromatography With On-Line High-Performance ESI FTICR Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yufeng (BATTELLE (PACIFIC NW LAB)); Tolic, Nikola (BATTELLE (PACIFIC NW LAB)); Zhao, Rui (ASSOC WESTERN UNIVERSITY); Pasa Tolic, Ljiljana (BATTELLE (PACIFIC NW LAB)); Li, Lingjun (Illinois Univ Of-Urbana/Champa); Berger, Scott J.(ASSOC WESTERN UNIVERSITY); Harkewicz, Richard (BATTELLE (PACIFIC NW LAB)); Anderson, Gordon A.(BATTELLE (PACIFIC NW LAB)); Belov, Mikhail E.(BATTELLE (PACIFIC NW LAB)); Smith, Richard D.(BATTELLE (PACIFIC NW LAB))

    2000-12-01

    We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system was operated at the pressure of 10,000 psi using commercial LC pumps to deliver the mobile phase and newly developed passive feedback valves to switch the mobile phase flow and introduce samples. The multiple-capillary LC system was composed of several serially connected dual-capillary column devices. The dual-capillary column approach was designed to eliminate the time delay for regeneration (or equilibrium) of the capillary column after its use under the mobile phase gradient condition (i.e. one capillary column was used in separation and the other was washed using mobile phase A). The serially connected dual-capillary columns and ESI sources were operated independently, and could be used for either''backup'' operation or with other mass spectrometer(s). This high-efficiency multiple-capillary LC system uses switching valves for all operations and is highly amenable to automation. The separations efficiency of dual-capillary column device, optimal capillary dimensions (column length and packed particle size), suitable mobile phases for electrospray, and the capillary re-generation were investigated. A high magnetic field (11.5 tesla) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system through an electrospray ionization source. The capillary LC provided a peak capacity of {approx}600, and the 2-D capillary LC-FTICR provided a combined resolving power of > 6 x 10 7 polypeptide isotopic distributions. For yeast cellular tryptic digests, > 100,000 polypeptides were typically detected, and {approx}1,000 proteins can be characterized in a single run.

  19. Capillary pumped loop body heat exchanger

    Science.gov (United States)

    Swanson, Theodore D. (Inventor); Wren, deceased, Paul (Inventor)

    1998-01-01

    A capillary pumped loop for transferring heat from one body part to another body part, the capillary pumped loop comprising a capillary evaporator for vaporizing a liquid refrigerant by absorbing heat from a warm body part, a condenser for turning a vaporized refrigerant into a liquid by transferring heat from the vaporized liquid to a cool body part, a first tube section connecting an output port of the capillary evaporator to an input of the condenser, and a second tube section connecting an output of the condenser to an input port of the capillary evaporator. A wick may be provided within the condenser. A pump may be provided between the second tube section and the input port of the capillary evaporator. Additionally, an esternal heat source or heat sink may be utilized.

  20. Study of capillary experiments and hydrologic factors under subsurface drip irrigation with fractal theory

    International Nuclear Information System (INIS)

    Zhou, W; Cao, L

    2012-01-01

    Soil spatial variability is one of the primary environmental factors that influences the hydraulic factors and technical indicators of subsurface drip irrigation (SDI), whose emitters are buried in the soil. This paper aimed at evaluating these effects of soil spatial variability on hydrologic factors under SDI. And some SDI emitter and capillary experiments were designed to obtain test data and distribution of pressure and emitter discharge. First, The results of labyrinth non-turbulent mosaic drip emitter test and fractal theory were used to research the fractal and quantitative relationship between single emitter hydrologic factors and soil physical parameters; and then, the capillary experiments and the relationship among hydrologic factors of capillary were used to analyze the fractal and quantitative relationship between hydrologic factors of capillary and soil physical parameters, which explained the inner relationship between spatial variability of soil and hydrologic factors of filed pipeline network under SDI, and provide theory support for the plan, design, management and production of SDI.

  1. Mass spectrometric diagnosis of an atmospheric pressure helium microplasma jet

    International Nuclear Information System (INIS)

    McKay, K; Oh, J-S; Walsh, J L; Bradley, J W

    2013-01-01

    Ambient molecular beam mass spectrometry (MBMS) has been used to study how different capillary widths (530 µm and 2.4 mm) and excitation waveforms (continuous wave kHz and pulsed dc) affect the ionic composition of atmospheric pressure plasma jets. It is shown from time-averaged ion intensities that reducing the width of the jet capillary results in a significant increase in the variety of both positive and negative ions detected within the discharge. We discuss this in terms of changes in flow velocity and the onset of turbulence within the plasma plume. Changing the mode of excitation had little effect on the ionic species detected from the microplasma jet; however, there was a notable shift in dominance towards higher mass ions when operated in a continuous wave kHz mode. The temporal evolution of the ions within the microplasma jet was observed for both excitation sources, operated at 5 and 15 kHz. Positive ions were created during periods correlated with the positive and negative peaks in discharge current, while negative ions were predominantly created at times when the discharge current peak was negative. This phenomenon was independent of the driving waveform. For pulsed dc excitation, considerably fewer positive ions were created in periods related to the negative current peaks, especially at higher frequencies. We propose a simple explanation for these processes based on ideas of streamer propagation and the influence of self-induced electric fields in the plasma plume. (paper)

  2. Intracranial capillary hemangioma mimicking a dissociative disorder

    Directory of Open Access Journals (Sweden)

    Alexander Lacasse

    2012-01-01

    Full Text Available Capillary hemangiomas, hamartomatous proliferation of vascular endothelial cells, are rare in the central nervous system (CNS. Intracranial capillary hemangiomas presenting with reversible behavioral abnormalities and focal neurological deficits have rarely been reported. We report a case of CNS capillary hemangioma presenting with transient focal neurological deficits and behavioral abnormalities mimicking Ganser’s syndrome. Patient underwent total excision of the vascular malformation, resulting in complete resolution of his symptoms.

  3. Capillary condensation between disks in two dimensions

    OpenAIRE

    Gil, Tamir; Ipsen, John Hjorth

    1997-01-01

    Capillary condensation between two two-dimensional wetted circular substrates (disks) is studied by an effective free energy description of the wetting interface. The interfacial free-energy potential is developed on the basis of the theory for the wetting of a single disk, where interfacial capillary fluctuations play a dominant role. A simple approximative analytical expression of the interfacial free energy is developed and is validated numerically. The capillary condensation is characteri...

  4. Effect of capillary condensation on friction force and adhesion.

    Science.gov (United States)

    Feiler, Adam A; Stiernstedt, Johanna; Theander, Katarina; Jenkins, Paul; Rutland, Mark W

    2007-01-16

    Friction force measurements have been conducted with a colloid probe on mica and silica (both hydrophilic and hydrophobized) after long (24 h) exposure to high-humidity air. Adhesion and friction measurements have also been performed on cellulose substrates. The long exposure to high humidity led to a large hysteresis between loading and unloading in the friction measurements with separation occurring at large negative applied loads. The large hysteresis in the friction-load relationship is attributed to a contact area hysteresis of the capillary condensate which built up during loading and did not evaporate during the unloading regime. The magnitude of the friction force varied dramatically between substrates and was lowest on the mica substrate and highest on the hydrophilic silica substrate, with the hydrophobized silica and cellulose being intermediate. The adhesion due to capillary forces on cellulose was small compared to that on the other substrates, due to the greater roughness of these surfaces.

  5. Capillary concentrators for synchrotron radiation beamlines

    International Nuclear Information System (INIS)

    Heald, S.M.; Brewe, D.L.; Kim, K.H.; Brown, F.C.; Barg, B.; Stern, E.A.

    1996-01-01

    Capillary concentrators condense x-rays by multiple reflections down a gradually tapering capillary. They can provide sub-micron beam spots, and are promising candidates for use in the next generation x-ray microprobe beamlines. The weak energy dependence of their properties make them especially useful for energy scanning applications such as micro-XAFS. This paper examines the potential performance of capillary optics for an x-ray microprobe, as well as some practical issues such as fabrication and alignment. Best performance at third generation sources requires long capillaries, and the authors have been using fiber optics techniques to fabricate capillaries up to one meter in length. The performance of shorter (less than about 0.5 m) capillaries has often been found to agree well with theoretical calculations, indicating the inner surface is a high quality x-ray reflector. These capillaries have been tested at the NSLS for imaging and micro-XAFS down to 2.6 microm resolution with excellent results. On an unfocused bend magnet line flux density approaching 10 6 ph/sec/microm 2 has been achieved. While nearly optimum profiles have been achieved for longer capillaries, the results have been disappointing, and alignment problems are suspected. The dramatic improvement in performance possible at third generation synchrotrons such as the APS is discussed along with improvements possible by using the capillaries in conjunction with coupling optics

  6. Slope wavenumber spectrum models of capillary and capillary-gravity waves

    Institute of Scientific and Technical Information of China (English)

    贾永君; 张杰; 王岩峰

    2010-01-01

    Capillary and capillary-gravity waves possess a random character, and the slope wavenumber spectra of them can be used to represent mean distributions of wave energy with respect to spatial scale of variability. But simple and practical models of the slope wavenumber spectra have not been put forward so far. In this article, we address the accurate definition of the slope wavenumber spectra of water surface capillary and capillary-gravity waves. By combining the existing slope wavenumber models and using th...

  7. Capillary electrophoresis and nanomaterials - Part I: Capillary electrophoresis of nanomaterials.

    Science.gov (United States)

    Adam, Vojtech; Vaculovicova, Marketa

    2017-10-01

    Nanomaterials are in analytical science used for a broad range of purposes, covering the area of sample pretreatment as well as separation, detection, and identification of target molecules. This part of the review covers capillary electrophoresis (CE) of nanomaterials and focuses on the application of CE as a method for characterization used during nanomaterial synthesis and modification as well as the monitoring of their properties and interactions with other molecules. The heterogeneity of the nanomaterial family is extremely large. Depending on different definitions of the term Nanomaterial/Nanoparticle, the group may cover metal and polymeric nanoparticles, carbon nanomaterials, liposomes and even dendrimers. Moreover, these nanomaterials are usually subjected to some kind of surface modification or functionalization, which broadens the diversity even more. Not only for purposes of verification of nanomaterial synthesis and batch-to-batch quality check, but also for determination the polydispersity and for functionality characterization on the nanoparticle surface, has CE offered very beneficial capabilities. Finally, the monitoring of interactions between nanomaterials and other (bio)molecules is easily performed by some kind of capillary electromigration technique. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. On the capillary restriction in start-up regimes of liquid metal evaporation from capillary-porous surfaces

    International Nuclear Information System (INIS)

    Prosvetov, V.V.

    1979-01-01

    Evaporation of liquid metals from capillary-porous structures is one of the most effective methods of surface cooling, to which essential heat quantity is delivered at high temperatures. The paper deals with heat flux limitation, caused by incapability of core capillary forces to overcome pressure differential in heat carrier circulation shape in such evaporation regimes, when average length of free path of vapour molecule exceeds core cell size. Suggested are theoretical correlations for determination of critical heat flux density and temperature of liquid surface in starting regimes of liquid metal evaporation from rectangular slots and compound cores with screens made of foil with round perforations. The catculative and experimental values of critical heat flux density in starting regimes of sodium evaporation from rectangular slots satisfactorily agree with each other

  9. Vacuum scanning capillary photoemission microscopy

    DEFF Research Database (Denmark)

    Aseyev, S.A.; Cherkun, A P; Mironov, B N

    2017-01-01

    of a gold reflecting layer on a compact disc which has been illuminated by an unfocused laser beam with a wavelength 400nm, from a femtosecond laser with a beam size of 4mm. A quartz capillary with a 2-µm aperture has been used in the experiments. The period of gold microstructure, shown to be 1.6µ...... distribution of the recorded photoelectrons consisted of periodic mountain-valley strips, resembling the surface profile of the sample. Submicron spatial resolution has been achieved. This approach paves the way to study pulsed photodesorption of large organic molecular ions with high spatial and element...

  10. Counteracting negative venous line pressures to avoid arterial air bubbles: an experimental study comparing two different types of miniaturized extracorporeal perfusion systems.

    Science.gov (United States)

    Aboud, Anas; Mederos-Dahms, Hendrikje; Liebing, Kai; Zittermann, Armin; Schubert, Harald; Murray, Edward; Renner, Andre; Gummert, Jan; Börgermann, Jochen

    2015-05-29

    Because of its low rate of clinical complications, miniaturized extracorporeal perfusion systems (MEPS) are frequently used in heart centers worldwide. However, many recent studies refer to the higher probability of gaseous microemboli formation by MEPS, caused by subzero pressure values. This is the main reason why various de-airing devices were developed for today's perfusion systems. In the present study, we investigated the potential benefits of a simple one-way-valve connected to a volume replacement reservoir (OVR) for volume and pressure compensation. In an experimental study on 26 pigs, we compared MEPS (n = 13) with MEPS plus OVR (n = 13). Except OVR, perfusion equipment was identical in both groups. Primary endpoints were pressure values in the venous line and the right atrium as well as the number and volume of air bubbles. Secondary endpoints were biochemical parameters of systemic inflammatory response, ischemia, hemodilution and hemolysis. One animal was lost in the MEPS + OVR group. In the MEPS + OVR group no pressure values below -150 mmHg in the venous line and no values under -100 mmHg in right atrium were noticed. On the contrary, nearly 20% of venous pressure values in the MEPS group were below -150 and approximately 10% of right atrial pressure values were below -100 mmHg. Compared with the MEPS group, the bubble counter device showed lower numbers of arterial air bubbles in the MEPS + OVR group (mean ± SD: 13444 ± 5709 vs. 1 ± 2, respectively; p pressures and to reduce the number and volume of arterial air bubbles. This approach may lead to a lower rate of neurological complications.

  11. On capillary self-focusing in a microfluidic system

    Energy Technology Data Exchange (ETDEWEB)

    Hein, M; Seemann, R [Experimental Physics, Saarland University, D-66123 Saarbrücken (Germany); Afkhami, S, E-mail: r.seemann@physik.uni-saarland.de, E-mail: shahriar.afkhami@njit.edu [Department of Mathematical Sciences, New Jersey Institute of Technology, Newark, NJ 07102 (United States)

    2016-12-15

    A computational framework is developed to address capillary self-focusing in step emulsification. The microfluidic system consists of a single shallow and wide microchannel that merges into a deep reservoir. A continuum approach coupled with a volume of fluid method is used to model the capillary self-focusing effect. The original governing equations are reduced using the Hele-Shaw approximation. We show that the interface between the two fluids takes the shape of a neck narrowing in the flow direction just before entering the reservoir, in agreement with our experimental observations. Our computational model relies on the assumption that the pressure at the boundary, where the fluid exits into the reservoir, is the uniform pressure in the reservoir. We investigate this hypothesis by comparing the numerical results with experimental data. We conjecture that the pressure boundary condition becomes important when the width of the neck is comparable to the depth of the microchannel. A correction to the exit pressure boundary condition is then proposed, which is determined by comparison with experimental data. We also present the experimental observations and the numerical results of the transitions of breakup regimes. (paper)

  12. High lung volume increases stress failure in pulmonary capillaries

    Science.gov (United States)

    Fu, Z.; Costello, M. L.; Tsukimoto, K.; Prediletto, R.; Elliott, A. R.; Mathieu-Costello, O.; West, J. B.

    1992-01-01

    We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological

  13. Ion guiding and losses in insulator capillaries

    International Nuclear Information System (INIS)

    Juhasz, Z.; Sulik, B.; Vikor, Gy.; Biri, S.; Fekete, E.; Ivan, I.; Gall, F.; Toekesi, K.; Matefi-Tempfli, S.; Matefi-Tempfli, M.

    2007-01-01

    Complete text of publication follows. Not long ago it was discovered that insulating capillaries can guide slow ions, so that the ions avoid close contact with the capillary walls and preserve their initial charge state. This phenomenon did not only give a new puzzle for theoreticians but opened the way for new possible applications where ions are manipulated (deflected, focused and directed to different patterns on the irradiated media) with small capillary devices. The most important question for such applications is how large fraction of the ions can be guided to the desired direction. It is already known that the ion guiding is due to the charging up of the inner capillary walls by earlier ion impact events. In tilted capillaries one side of the capillary walls charges up. This deflects the later arriving ions, so that some of them pass through the capillaries nearly parallel with respect to their axes. The angle where the transmission drops to 1/e of the direct transmission at 0 deg is the guiding angle, which characterize the guiding ability. At 0 deg the ideal 100 percent transmission for the ions, which enter the capillaries, is reduced due to the mirror charge attraction and geometrical imperfections. These losses appear in the transmission for tilted capillaries with similar magnitude, since after the deflection region, which usually restricted to the close surroundings of the capillary openings, the guided ions pass through the rest of the capillaries as in non-tilted samples. In our experimental studies with Al 2 O 3 capillaries we found that around 90 percent of the incoming ions are lost. To understand these significant losses, the effects of the mirror charge attraction and geometrical imperfections have been calculated classically. The mirror charge potential was taken from.The model of the capillaries used in the calculations can be seen in Figure 1. The calculations have shown that the effects of mirror charge attraction and the angular

  14. Two-dimensional capillary origami

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, N.D., E-mail: nbrubaker@math.arizona.edu; Lega, J., E-mail: lega@math.arizona.edu

    2016-01-08

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  15. Two-dimensional capillary origami

    International Nuclear Information System (INIS)

    Brubaker, N.D.; Lega, J.

    2016-01-01

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  16. Structures of Bordered Pits Potentially Contributing to Isolation of a Refilled Vessel from Negative Xylem Pressure in Stems of Morus australis Poir.: Testing of the Pit Membrane Osmosis and Pit Valve Hypotheses.

    Science.gov (United States)

    Ooeda, Hiroki; Terashima, Ichiro; Taneda, Haruhiko

    2017-02-01

    Two hypotheses have been proposed to explain the mechanism preventing the refilling vessel water from being drained to the neighboring functional vessels under negative pressure. The pit membrane osmosis hypothesis proposes that the xylem parenchyma cells release polysaccharides that are impermeable to the intervessel pit membranes into the refilling vessel; this osmotically counteracts the negative pressure, thereby allowing the vessel to refill. The pit valve hypothesis proposes that gas trapped within intervessel bordered pits isolates the refilling vessel water from the surrounding functional vessels. Here, using the single-vessel method, we assessed these hypotheses in shoots of mulberry (Morus australis Poir.). First, we confirmed the occurrence of xylem refilling under negative pressure in the potted mulberry saplings. To examine the pit membrane osmosis hypothesis, we estimated the semi-permeability of pit membranes for molecules of various sizes and found that the pit membranes were not semi-permeable to polyethylene glycol of molecular mass osmosis mechanism in mulberry would be unrealistically large. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Inactivation of Gram-Negative Bacteria by Low-Pressure RF Remote Plasma Excited in N2-O2 Mixture and SF6 Gases

    Directory of Open Access Journals (Sweden)

    Ayman Al-Mariri

    2013-12-01

    Full Text Available The role of low-pressure RF plasma in the inactivation of Escherichia coli O157, Klebsiella pneumoniae, Proteus mirabilis, and Enterobacter sakazakii using N2-O2 and SF6 gases was assessed. 1×109 colony-forming units (CFUs of each bacterial isolate were placed on three polymer foils. The effects of pressure, power, distance from the source, and exposure time to plasma gases were optimized. The best conditions to inactivate the four bacteria were a 91%N2-9%O2 mixture and a 30-minute exposure time. SF6 gas was more efficient for all the tested isolates in as much as the treatment time was reduced to only three minutes. Therefore, low-pressure plasma could be used to sterilize heat and/or moisture-sensitive medical instruments.

  18. Mathematical Modelling of Intraretinal Oxygen Partial Pressure

    African Journals Online (AJOL)

    Erah

    The system of non-linear differential equations was solved numerically using Runge-kutta. Nystroms method. ... artery occlusion. Keywords: Mathematical modeling, Intraretinal oxygen pressure, Retinal capillaries, Oxygen ..... Mass transfer,.

  19. Equilibrium capillary forces with atomic force microscopy

    NARCIS (Netherlands)

    Sprakel, J.H.B.; Besseling, N.A.M.; Leermakers, F.A.M.; Cohen Stuart, M.A.

    2007-01-01

    We present measurements of equilibrium forces resulting from capillary condensation. The results give access to the ultralow interfacial tensions between the capillary bridge and the coexisting bulk phase. We demonstrate this with solutions of associative polymers and an aqueous mixture of gelatin

  20. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  1. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  2. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Science.gov (United States)

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  3. Influence of local capillary trapping on containment system effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Steven [University Of Texas At Austin, Austin, TX (United States). Center for Petroleum and Geosystems Engineering

    2014-03-31

    Immobilization of CO2 injected into deep subsurface storage reservoirs is a critical component of risk assessment for geologic CO2 storage (GCS). Local capillary trapping (LCT) is a recently established mode of immobilization that arises when CO2 migrates due to buoyancy through heterogeneous storage reservoirs. This project sought to assess the amount and extent of LCT expected in storage formations under a range of injection conditions, and to confirm the persistence of LCT if the seal overlying the reservoir were to lose its integrity. Numerical simulation using commercial reservoir simulation software was conducted to assess the influence of injection. Laboratory experiments, modeling and numerical simulation were conducted to assess the effect of compromised seal integrity. Bench-scale (0.6 m by 0.6 m by 0.03 m) experiments with surrogate fluids provided the first empirical confirmation of the key concepts underlying LCT: accumulation of buoyant nonwetting phase at above residual saturations beneath capillary barriers in a variety of structures, which remains immobile under normal capillary pressure gradients. Immobilization of above-residual saturations is a critical distinction between LCT and the more familiar “residual saturation trapping.” To estimate the possible extent of LCT in a storage reservoir an algorithm was developed to identify all potential local traps, given the spatial distribution of capillary entry pressure in the reservoir. The algorithm assumes that the driving force for CO2 migration can be represented as a single value of “critical capillary entry pressure” Pc,entrycrit, such that cells with capillary entry pressure greater/less than Pc,entrycrit act as barriers/potential traps during CO2 migration. At intermediate values of Pc,entrycrit, the barrier regions become more laterally extensive in the reservoir

  4. Investigation of the effect of mechanical pressure on the performance of negative lead accumulator electrodes during partial state of charge operation

    Czech Academy of Sciences Publication Activity Database

    Bača, P.; Micka, Karel; Křivík, P.; Tonar, K.; Tošer, P.

    2012-01-01

    Roč. 207, JUN 1 2012 (2012), s. 37-44 ISSN 0378-7753 Institutional research plan: CEZ:AV0Z40400503 Keywords : Lead battery electrodes * Doping with carbon or titanium dioxide * Effect of mechanical pressure Subject RIV: CG - Electrochemistry Impact factor: 4.675, year: 2012

  5. When negation is not negation

    OpenAIRE

    Milicevic, Nataša

    2008-01-01

    In this paper I will discuss the formation of different types of yes/no questions in Serbian (examples in (1)), focusing on the syntactically and semantically puzzling example (1d), which involves the negative auxiliary inversion. Although there is a negative marker on the fronted auxiliary, the construction does not involve sentential negation. This coincides with the fact that the negative quantifying NPIs cannot be licensed. The question formation and sentential negation have similar synta...

  6. Possibilities of testing capillary absorption on microcores

    Directory of Open Access Journals (Sweden)

    Čeh Arpad

    2016-01-01

    Full Text Available During inspection of reinforced concrete structures from the aspect of durability evaluation of concrete, the present methods generally use the test results obtained by the sophisticated and expensive equipment, which are usually not universal purpose, ie. they can be used only for one segment of durability evaluation of the concrete. This way any additional information about the condition of concrete is valuable, especially if it is not require an additional testing with special equipment. Tests of concrete and reinforced concrete with microcore drilling is considered to be a semi- destructive method, which slightly damages the structure itself, and it is primarily used for testing carbonation, density and absorption of concrete. The paper presents the results of capillary absorption according to SRPS EN 480-5 on standard-size samples and on the microcores extracted from cube form samples with edge length of 20 cm. In the article the testing results of penetration of water under pressure are also presented on the same samples, on which we previously gained microcores. These tests were carried out on with concrete mixtures designed for the most demanding exposure classes according to EN 206-1 and using a variety of additives that are known to affect the structure of pores and consequently also the durability of a hardened concrete.

  7. Solvent jet desorption capillary photoionization-mass spectrometry.

    Science.gov (United States)

    Haapala, Markus; Teppo, Jaakko; Ollikainen, Elisa; Kiiski, Iiro; Vaikkinen, Anu; Kauppila, Tiina J; Kostiainen, Risto

    2015-03-17

    A new ambient mass spectrometry method, solvent jet desorption capillary photoionization (DCPI), is described. The method uses a solvent jet generated by a coaxial nebulizer operated at ambient conditions with nitrogen as nebulizer gas. The solvent jet is directed onto a sample surface, from which analytes are extracted into the solvent and ejected from the surface in secondary droplets formed in collisions between the jet and the sample surface. The secondary droplets are directed into the heated capillary photoionization (CPI) device, where the droplets are vaporized and the gaseous analytes are ionized by 10 eV photons generated by a vacuum ultraviolet (VUV) krypton discharge lamp. As the CPI device is directly connected to the extended capillary inlet of the MS, high ion transfer efficiency to the vacuum of MS is achieved. The solvent jet DCPI provides several advantages: high sensitivity for nonpolar and polar compounds with limit of detection down to low fmol levels, capability of analyzing small and large molecules, and good spatial resolution (250 μm). Two ionization mechanisms are involved in DCPI: atmospheric pressure photoionization, capable of ionizing polar and nonpolar compounds, and solvent assisted inlet ionization capable of ionizing larger molecules like peptides. The feasibility of DCPI was successfully tested in the analysis of polar and nonpolar compounds in sage leaves and chili pepper.

  8. Numerical simulation and experimental validation of coiled adiabatic capillary tubes

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valladares, O. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico (UNAM), Apdo. Postal 34, 62580 Temixco, Morelos (Mexico)

    2007-04-15

    The objective of this study is to extend and validate the model developed and presented in previous works [O. Garcia-Valladares, C.D. Perez-Segarra, A. Oliva, Numerical simulation of capillary tube expansion devices behaviour with pure and mixed refrigerants considering metastable region. Part I: mathematical formulation and numerical model, Applied Thermal Engineering 22 (2) (2002) 173-182; O. Garcia-Valladares, C.D. Perez-Segarra, A. Oliva, Numerical simulation of capillary tube expansion devices behaviour with pure and mixed refrigerants considering metastable region. Part II: experimental validation and parametric studies, Applied Thermal Engineering 22 (4) (2002) 379-391] to coiled adiabatic capillary tube expansion devices working with pure and mixed refrigerants. The discretized governing equations are coupled using an implicit step by step method. A special treatment has been implemented in order to consider transitions (subcooled liquid region, metastable liquid region, metastable two-phase region and equilibrium two-phase region). All the flow variables (enthalpies, temperatures, pressures, vapor qualities, velocities, heat fluxes, etc.) together with the thermophysical properties are evaluated at each point of the grid in which the domain is discretized. The numerical model allows analysis of aspects such as geometry, type of fluid (pure substances and mixtures), critical or non-critical flow conditions, metastable regions, and transient aspects. Comparison of the numerical simulation with a wide range of experimental data presented in the technical literature will be shown in the present article in order to validate the model developed. (author)

  9. Gas adsorption and capillary condensation in nanoporous alumina films

    Energy Technology Data Exchange (ETDEWEB)

    Casanova, Felix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Schuller, Ivan K [Physics Department, University of California-San Diego, La Jolla, CA 92093 (United States); Ruminski, Anne M; Sailor, Michael J [Department of Chemistry and Biochemistry, University of California-San Diego, La Jolla, CA 92093 (United States)], E-mail: casanova@physics.ucsd.edu

    2008-08-06

    Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good agreement with independent structural measurements. The condensation for toluene lacks reproducibility due to incomplete surface wetting. This exemplifies the relevant role of the fluid-solid (van der Waals) interactions in the hysteretic behavior of capillary condensation.

  10. Gas adsorption and capillary condensation in nanoporous alumina films

    International Nuclear Information System (INIS)

    Casanova, Felix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Schuller, Ivan K; Ruminski, Anne M; Sailor, Michael J

    2008-01-01

    Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good agreement with independent structural measurements. The condensation for toluene lacks reproducibility due to incomplete surface wetting. This exemplifies the relevant role of the fluid-solid (van der Waals) interactions in the hysteretic behavior of capillary condensation

  11. Gas adsorption and capillary condensation in nanoporous alumina films.

    Science.gov (United States)

    Casanova, Fèlix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Ruminski, Anne M; Sailor, Michael J; Schuller, Ivan K

    2008-08-06

    Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good a