WorldWideScience

Sample records for multiple crush biopsy

  1. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  2. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  3. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  4. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  5. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  6. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  7. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  8. DK crush (double-kissing and double-crush) technique for treatment of true coronary bifurcation lesions: illustration and comparison with classic crush.

    Science.gov (United States)

    Chen, Shaoliang; Zhang, Junjie; Ye, Fei; Zhu, Zhongsheng; Lin, Song; Shan, Shoujie; Kwan, Tak W

    2007-04-01

    Classic crush has a lower success rate compared to final kissing balloon inflation (FKBI). We previously reported the double-kissing (DK) crush technique that involves double-kissing along with double-crushing for the treatment of true bifurcation coronary lesions in 2005. This is a consecutive, nonrandomized, open-label study. Eighty-eight consecutive patients with single, true coronary bifurcation lesions according to Lefevre Classification2 and side branch diameter >2.0 mm were enrolled. The first 44 patients (from October 2004 to January 2005) were assigned to the classic crush treatment arm and the next 44 patients (from February 2005 to June 2005) were assigned to the DK crush technique arm, respectively. Data within 30 days were analyzed. Patients in the DK crush group, compared to those in classic crush group, were characterized by longer lesion length in the side branch (13.5 +/- 3.4 mm vs 7.8 +/- 3.1 mm; p DK crush group, as well as longer lesion length in the main vessel (24.3 +/- 8.6 mm vs 21.1 +/- 7.3 mm), though without significant differences (p >0.05). Subacute stent thrombosis was detected in 2 patients with failure of FKBI in the classic crush group (4.3%). In addition, patients in the classic crush group were characterized by a smaller minimum lumen diameter (MLD) at the side branch ostium (2.74 +/- 0.12 mm vs 3.01 +/- 0.13 mm; p DK crush has the potential to improve the clinical outcome in patients with coronary bifurcation lesions. Further randomized, prospective, multicenter studies are required to confirm these differences between the classic crush and DK crush techniques.

  9. Automation for Crushing and Screening Equipment to Produce Graded Paving Crushed Stone

    Science.gov (United States)

    Tikhonov, Anatoly; Velichkin, Vladimir

    2017-10-01

    This paper offers analysis of factors related to production and storage of graded crushed stone, which adversely impact the service life and wear resistance of asphalt-concrete motor road pavements. The paper describes external and technology-related parameters that may cause changes of the preset ratio in graded crushed stone. Control factors are described that ensure the formulated fraction ratio in crushed stone by controlling the operation mode of the crushing and screening equipment. The paper also contains an ACS flow chart for crushing and screening equipment engaged in continuous closed-cycle two-stage technology. Performance of the ACS to maintain the preset fractionated crushed stone ratio has been confirmed with a mathematical model.

  10. Crush Grinding

    International Nuclear Information System (INIS)

    Nguyen, T.Q.

    2005-01-01

    Crush Grinding is a special process used at the Kansas City Plant to finish stem sections of reservoir products. In this process, a precise profile of the desired product is formed on a tungsten carbide roll. This roll slowly transfers a mirror image of the profile onto the grinding surface of a wheel. The transfer rate of the profile is between 0.001 and 0.010 inches per minute. Crush grinding is desirable since it provides consistent surface finishes and thin walls at a high production rate. In addition, it generates very sharp fillet radii. However, crush grinding is a complex process since many variables affect the final product. Therefore, the process requires more attention and knowledge beyond basic metal removal practices. While the Kansas City Plant began using these machines in 1995, a formal study regarding crush grinding has not been conducted there. In addition, very little literature is available in the grinding industry regarding this process. As a result, new engineers at the Kansas City Plant must learn the process through trial and error. The purpose of this document is to address this literature deficit while specifically promoting a better understanding of the stem crush grinding process at the Kansas City Plant.

  11. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    International Nuclear Information System (INIS)

    Wallace, Adam N.; Pacheco, Rafael A.; Tomasian, Anderanik; Hsi, Andy C.; Long, Jeremiah; Chang, Randy O.; Jennings, Jack W.

    2016-01-01

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact

  12. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Hsi, Andy C., E-mail: hsia@path.wustl.edu [Washington University School of Medicine, Division of Anatomic Pathology, Department of Pathology & Immunology (United States); Long, Jeremiah, E-mail: longj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

  13. 21 CFR 137.195 - Crushed wheat.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Crushed wheat. 137.195 Section 137.195 Food and... Related Products § 137.195 Crushed wheat. Crushed wheat, coarse ground wheat, is the food prepared by so crushing cleaned wheat other than durum wheat and red durum wheat that, when tested by the method...

  14. Crush Testing at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Feldman, Matthew R.

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

  15. Classic crush and DK crush stenting techniques.

    Science.gov (United States)

    Zhang, Jun-Jie; Chen, Shao-Liang

    2015-01-01

    Clinical data have supported the advantages of the double kissing (DK) crush technique, which consists of stenting the side branch (SB), balloon crush, first kissing, stenting the main vessel (MV) and final kissing balloon inflation, for complex coronary bifurcation lesions compared to other stenting techniques. Careful rewiring from the proximal cell of the MV stent to make sure the wire is in the true lumen of the SB stent is key to acquiring optimal angiographic results. Balloon anchoring from the MV, alternative inflation and each kissing inflation using large enough non-compliant balloons at high pressure, and the proximal optimisation technique are mandatory to improve both angiographic and clinical outcomes. Stratification of a given bifurcation lesion is recommended before decision making.

  16. Baseline effects of lysophosphatidylcholine and nerve growth factor in a rat model of sciatic nerve regeneration after crush injury

    Directory of Open Access Journals (Sweden)

    Ryan L Wood

    2018-01-01

    Full Text Available Schwann cells play a major role in helping heal injured nerves. They help clear debris, produce neurotrophins, upregulate neurotrophin receptors, and form bands of Büngner to guide the healing nerve. But nerves do not always produce enough neurotrophins and neurotrophin receptors to repair themselves. Nerve growth factor (NGF is an important neurotrophin for promoting nerve healing and lysophosphatidylcholine (LPC has been shown to stimulate NGF receptors (NGFR. This study tested the administration of a single intraneural injection of LPC (1 mg/mL for single LPC injection and 10 mg/mL for multiple LPC injections at day 0 and one (day 7, two (days 5 and 7, or three (days 5, 7, and 9 injections of NGF (160 ng/mL for single injections and 80 ng/mL for multiple injections to determine baseline effects on crushed sciatic nerves in rats. The rats were randomly divided into four groups: control, crush, crush-NGF, and crush-LPC-NGF. The healing of the nerves was measured weekly by monitoring gait; electrophysiological parameters: compound muscle action potential (CMAP amplitudes; and morphological parameters: total fascicle areas, myelinated fiber counts, fiber densities, fiber packing, and mean g-ratio values at weeks 3 and 6. The crush, crush-NGF, and crush-LPC-NGF groups statistically differed from the control group for all six weeks for the electrophysiological parameters but only differed from the control group at week 3 for the morphological parameters. The crush, crush-NGF, and crush-LPC-NGF groups did not differ from each other over the course of the study. Single injections of LPC and NGF one week apart or multiple treatments of NGF at 5, 7 and 9 days post-injury did not alter the healing rate of the sciatic nerves during weeks 1-6 of the study. These findings are important to define the baseline effects of NGF and LPC injections, as part of a larger effort to determine the minimal dose regimen of NGF to regenerate peripheral nerves.

  17. [Experimental study on establishment of a simple model of rats crush injury-crush syndrome].

    Science.gov (United States)

    Chen, Xi; Liu, Yuehong; Xu, Wei; Qin, Tingwu; Zhao, Luping; Liu, Shuping; Zhang, Yi; Tan, Hong; Zhou, Yu

    2013-01-01

    To establish a repeatable, simple, and effective model of rat crush injury and crush syndrome. A total of 42 female Sprague Dawley rats (2-month-old, (CS) so as to lay a foundation for further study on CS. weighing 160-180 g) were divided randomly into the control group (n=6) and experimental group (n=36). The rats of the experimental group were used to establish the crush injury and CS model in both lower limbs by self-made crush injury mould. The survival rate and hematuria rate were observed after decompression. The biochemical indexes of blood were measured at 2, 4, 8, 12, 24, and 48 hours after decompression. The samples of muscle, kidney, and heart were harvested for morphological observation. There was no treatment in the control group, and the same tests were performed. Seven rats died and 15 rats had hematuria during compression in the experimental group. Swelling of the lower limb and muscle tissue was observed in the survival rats after reperfusion. The liver function test results showed that the levels of alanine transaminase and aspartate aminotransferase in the experimental group were significantly higher than those in the control group (P congestion and swelling, renal tubular epithelial cell degeneration, edema, necrosis, and myoglobin tube type were found in the kidneys; and myocardial structure had no obvious changes. The method of the crush injury and CS model by self-made crush injury mould is a simple and effective procedure and the experimental result is stable. It is a simple method to establish an effective model of rats crush injury and CS.

  18. Thermophysical properties of reconsolidating crushed salt.

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Urquhart, Alexander [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-03-01

    Reconsolidated crushed salt is being considered as a backfilling material placed upon nuclear waste within a salt repository environment. In-depth knowledge of thermal and mechanical properties of the crushed salt as it reconsolidates is critical to thermal/mechanical modeling of the reconsolidation process. An experimental study was completed to quantitatively evaluate the thermal conductivity of reconsolidated crushed salt as a function of porosity and temperature. The crushed salt for this study came from the Waste Isolation Pilot Plant (WIPP). In this work the thermal conductivity of crushed salt with porosity ranging from 1% to 40% was determined from room temperature up to 300°C, using two different experimental methods. Thermal properties (including thermal conductivity, thermal diffusivity and specific heat) of single-crystal salt were determined for the same temperature range. The salt was observed to dewater during heating; weight loss from the dewatering was quantified. The thermal conductivity of reconsolidated crushed salt decreases with increasing porosity; conversely, thermal conductivity increases as the salt consolidates. The thermal conductivity of reconsolidated crushed salt for a given porosity decreases with increasing temperature. A simple mixture theory model is presented to predict and compare to the data developed in this study.

  19. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    Science.gov (United States)

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  20. Crushed Salt Constitutive Model

    International Nuclear Information System (INIS)

    Callahan, G.D.

    1999-01-01

    The constitutive model used to describe the deformation of crushed salt is presented in this report. Two mechanisms -- dislocation creep and grain boundary diffusional pressure solution -- are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Upon complete consolidation, the crushed-salt model reproduces the Multimechanism Deformation (M-D) model typically used for the Waste Isolation Pilot Plant (WIPP) host geological formation salt. New shear consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on WIPP and southeastern New Mexico salt. Nonlinear least-squares model fitting to the database produced two sets of material parameter values for the model -- one for the shear consolidation tests and one for a combination of the shear and hydrostatic consolidation tests. Using the parameter values determined from the fitted database, the constitutive model is validated against constant strain-rate tests. Shaft seal problems are analyzed to demonstrate model-predicted consolidation of the shaft seal crushed-salt component. Based on the fitting statistics, the ability of the model to predict the test data, and the ability of the model to predict load paths and test data outside of the fitted database, the model appears to capture the creep consolidation behavior of crushed salt reasonably well

  1. Expression of Wnt-Inhibitors and SDF-1 in Whole Bone Marrow Biopsies in Association to the Osteolytic Bone Disease of Multiple Myeloma

    DEFF Research Database (Denmark)

    Kristensen, Ida Bruun; Christensen, Jacob Haaber; Lyng, Maria Bibi

    Expression of Wnt-Inhibitors and SDF-1 in Whole Bone Marrow Biopsies in Association to the Osteolytic Bone Disease of Multiple Myeloma......Expression of Wnt-Inhibitors and SDF-1 in Whole Bone Marrow Biopsies in Association to the Osteolytic Bone Disease of Multiple Myeloma...

  2. Crushing method for nuclear fuel powder

    International Nuclear Information System (INIS)

    Hasegawa, Shin-ichi; Tsuchiya, Haruo.

    1997-01-01

    A crushing medium is contained in mill pots disposed at the circumferential periphery of a main axis. The diameter of each mill pot is determined such that powdery nuclear fuels containing aggregated powders and ground and mixed powders do not reach criticality. A plurality of mill pots are revolved in the direction of the main axis while each pots rotating on its axis. Powdery nuclear fuels containing aggregated powders are conveyed to a supply portion of the moll pot, and an inert gas is supplied to the supply portion. The powdery nuclear fuels are supplied from the supply portion to the inside of the mill pots, and the powdery nuclear fuels containing aggregated powders are crushed by centrifugal force caused by the rotation and the revolving of the mill pots by means of the crushing medium. UO 2 powder in uranium oxide fuels can be crushed continuously. PuO 2 powder and UO 2 powder in MOX fuels can be crushed and mixed continuously. (I.N.)

  3. Determination of dispersity of crushed granite

    International Nuclear Information System (INIS)

    Liu Dejun; Fan Xianhua; Zhang Yingjie; Yao Jun; Zhou Duo; Wang Yong

    2004-01-01

    The experimental crushed granite column breakthrough curves, using 99 Tc as spike tracer and 3 H as invariant tracer, are analyzed by different linear regression techniques. Dispersity of crushed granite and retardation factor of 99 TcO 4 - on the crushed granite are determined simultaneously by one linear regression technique. Dispersity of crushed granite is also obtained with 3 H as invariant tracer by the other linear regression technique. The dispersities found by spike source and invariant source methods are compared. The experimental results show that the dispersity found by spike source method is close to that found by invariant source method. It indicates that dispersity is only the characteristic of dispersion medium

  4. Determination of dispersity of crushed granite

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    Experimental crushed granite column breakthrough curves, using 99 Tc as spike tracer and 3 H as invariant tracer, were analyzed by different linear regression techniques. Dispersity of crushed granite and the retardation factor of 99 TcO 4 - on the crushed granite were determined simultaneously by one linear regression. Dispersity of crushed granite was also obtained with 3 H as invariant tracer by the other linear regression. The dispersities found by spike source and invariant source methods are compared. Experimental results show that the dispersity found by the spike source method is close to that found by the invariant source method. This indicates that dispersity is only a characteristic of the dispersion medium. (author)

  5. Usage of Crushed Concrete Fines in Decorative Concrete

    Science.gov (United States)

    Pilipenko, Anton; Bazhenova, Sofia

    2017-10-01

    The article is devoted to the questions of usage of crushed concrete fines from concrete scrap for the production of high-quality decorative composite materials based on mixed binder. The main problem in the application of crushed concrete in the manufacture of decorative concrete products is extremely low decorative properties of crushed concrete fines itself, as well as concrete products based on them. However, crushed concrete fines could have a positive impact on the structure of the concrete matrix and could improve the environmental and economic characteristics of the concrete products. Dust fraction of crushed concrete fines contains non-hydrated cement grains, which can be opened in screening process due to the low strength of the contact zone between the hydrated and non-hydrated cement. In addition, the screening process could increase activity of the crushed concrete fines, so it can be used as a fine aggregate and filler for concrete mixes. Previous studies have shown that the effect of the usage of the crushed concrete fines is small and does not allow to obtain concrete products with high strength. However, it is possible to improve the efficiency of the crushed concrete fines as a filler due to the complex of measures prior to mixing. Such measures may include a preliminary mechanochemical activation of the binder (cement binder, iron oxide pigment, silica fume and crushed concrete fines), as well as the usage of polycarboxylate superplasticizers. The development of specific surface area of activated crushed concrete fines ensures strong adhesion between grains of binder and filler during the formation of cement stone matrix. The particle size distribution of the crushed concrete fines could achieve the densest structure of cement stone matrix and improve its resistance to environmental effects. The authors examined the mechanisms of structure of concrete products with crushed concrete fines as a filler. The results of studies of the properties of

  6. A numerical approach to model and predict the energy absorption and crush mechanics within a long-fiber composite crush tube

    Science.gov (United States)

    Pickett, Leon, Jr.

    Past research has conclusively shown that long fiber structural composites possess superior specific energy absorption characteristics as compared to steel and aluminum structures. However, destructive physical testing of composites is very costly and time consuming. As a result, numerical solutions are desirable as an alternative to experimental testing. Up until this point, very little numerical work has been successful in predicting the energy absorption of composite crush structures. This research investigates the ability to use commercially available numerical modeling tools to approximate the energy absorption capability of long-fiber composite crush tubes. This study is significant because it provides a preliminary analysis of the suitability of LS-DYNA to numerically characterize the crushing behavior of a dynamic axial impact crushing event. Composite crushing theory suggests that there are several crushing mechanisms occurring during a composite crush event. This research evaluates the capability and suitability of employing, LS-DYNA, to simulate the dynamic crush event of an E-glass/epoxy cylindrical tube. The model employed is the composite "progressive failure model", a much more limited failure model when compared to the experimental failure events which naturally occur. This numerical model employs (1) matrix cracking, (2) compression, and (3) fiber breakage failure modes only. The motivation for the work comes from the need to reduce the significant cost associated with experimental trials. This research chronicles some preliminary efforts to better understand the mechanics essential in pursuit of this goal. The immediate goal is to begin to provide deeper understanding of a composite crush event and ultimately create a viable alternative to destructive testing of composite crush tubes.

  7. Characterizing large strain crush response of redwood

    International Nuclear Information System (INIS)

    Cramer, S.M.; Hermanson, J.C.

    1996-12-01

    Containers for the transportation of hazardous and radioactive materials incorporate redwood in impact limiters. Redwood is an excellent energy absorber, but only the most rudimentary information exists on its crush properties. The objectives of the study were to fill the information gap by collecting triaxial load-deformation data for redwood; to use these data to characterize redwood crush, assess current wood failure theories, provide developments toward a complete stress-strain theory for redwood; and to review the literature on strain-rate effects on redwood crush performance. The load-deformation responses of redwood at temperature conditions corresponding to ambient (70 degrees F), 150 degrees F, and -20 degrees F conditions were measured in approximately 100 confined compression tests for crush levels leading to material densification. Data analysis provided a more complete description of redwood crush performance and a basis for assessing proposed general orthotropic stress-strain relationships for redwood. A review of existing literature indicated that strain-rate effects cause at most a 20 percent increase in crush stress parallel to grain

  8. Crushed stone production plant for NPP building

    International Nuclear Information System (INIS)

    Obolenskij, V.Ya.

    1982-01-01

    The project of the granite-crushed stone quarry - the large modern plant producing building materials, is presented. The quarry is designated for providing NPP and other power objects building with high-strength crushed stone. The plant consists of: quarry; crushing-sorting plant with maintenance objects arranged on its ground; basis and service stores of explosive materials; tail facility and purifying systems; water supply purifying stations; water storage basin. The plant is reserved for 2335 thousand m 3 yearly utoput of crushed stone; the staff consists of 535 persons, the budgeted cost of building is 26.6 million rubles. Physicochemical characteristics of granosyenites of the ''Granitnoye'' deposit - the raw material resource base of the plant and technological scheme of the crushing-sorting plant are given. Planned measures on building organization and recultivation of disturbed grounds are presented

  9. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  10. Crushing of ship bows in head-on collision

    DEFF Research Database (Denmark)

    Ocakli, H.; Zhang, S.; Pedersen, Preben Terndrup

    2004-01-01

    Semi-analytical methods for analysis of plate crushing and ship bow damage in head-on collisions are developed in this paper. Existing experimental and theoretical studies for crushing analysis of plated structures are summarized and compared. Simple formulae for determining the crushing force....... The approach developed can be used easily to determine the crushing resistance and damage extent of the ship bow when ship length and collision speed are known. The method can be used in probabilistic analysis of damage extents in ship collisions where a large number of calculations are generally required....

  11. Studies on various characteristics of concrete structures using crushed sand

    International Nuclear Information System (INIS)

    Mimatsu, Makoto; Sugita, Hideaki; Yonemura, Masataka.

    1985-01-01

    With the recent advances of construction industry, the demands for concrete, hence for aggregate, are rising. The sand as such is in extreme shortage due to the exhaustion of river sand. Under the situation, the recent trends are for the use of crushed sand, i.e. the artificial sand obtained by crushing rocks, which have advantages of stabilized quality and adequate supplies. In building of nuclear power plants requiring large amounts of concrete, the usage of crushed sand is now unavoidable. The following are described : the situation of aggregate in Kyushu. production method of crushed sand and the quality standards, rocks used for crushed stone and sand and the properties, quality survey on crushed sand and the basic tests, characteristic tests of crushed-stone and -sand mixed concrete, the application of crushed sand in structures of the Sendai Nuclear Power Station. (Mori, K.)

  12. Crushed Stone Operations

    Data.gov (United States)

    Department of Homeland Security — This map layer includes crushed stone operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  13. Compartment and Crush Syndromes After Sleep Deprivation and a Therapeutic Dose of Zolpidem

    Directory of Open Access Journals (Sweden)

    Martin R. Huecker

    2017-07-01

    Full Text Available Despite extensive review in the literature, compartment syndrome and crush syndrome remain difficult to diagnose. Trauma, toxins and reperfusion have been associated with these syndromes. Cases involving alcohol and drug abuse have described patients “found down” compressing an extremity. We present a case of a registered nurse who developed compartment syndrome in multiple limbs due to prolonged sleep after sleep deprivation and zolpidem use. To our knowledge, this is the first case of compartment syndrome or crush syndrome to have occurred in the setting of zolpidem use. Sleep disruption in healthcare workers represents a public health issue with dangerous sequelae, both acute and chronic.

  14. Study comparing the double kissing (DK) crush with classical crush for the treatment of coronary bifurcation lesions: the DKCRUSH-1 Bifurcation Study with drug-eluting stents.

    Science.gov (United States)

    Chen, S L; Zhang, J J; Ye, F; Chen, Y D; Patel, T; Kawajiri, K; Lee, M; Kwan, T W; Mintz, G; Tan, H C

    2008-06-01

    Classical crush has a lower rate of final kissing balloon inflation (FKBI) immediately after percutaneous coronary intervention (PCI). The double kissing (DK) crush technique has the potential to increase the FKBI rate, and no prospective studies on the comparison of classical with DK crush techniques have been reported. Three hundred and eleven patients with true bifurcation lesions were randomly divided into classical (n = 156) and DK crush (n = 155) groups. Clinical and angiographic details at follow-up at 8 months were indexed. The primary end point was major adverse cardiac events (MACE) including myocardial infarction, cardiac death and target lesion revascularization (TLR) at 8 months. FKBI was 76% in the classical crush group and 100% in the DK group (P DK crush group. Cumulative 8 month MACE was 24.4% in the classical crush group and 11.4% in the DK crush group (P = 0.02). The TLR-free survival rate was 75.4% in the classical crush group and 89.5% in the DK crush group (P = 0.002). DK crush technique has the potential of increasing FKBI rate and reducing stent thrombosis, with a further reduction of TLR and cumulative MACE rate at 8 months.

  15. A Case of Multiple Splenic Lymph angiomas Diagnosed by Percutaneous Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Seung Seog; Jeong, Sook Hyang; Yoon, Chang Jin; Chang, Se Jung; Choi, Joon Hyuk; Ha, Ji Su; Kim, Soon Je [KEPCO Medical foundation Hanil General Hospital, Seoul (Korea, Republic of); Lee, Hye Seung [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2007-06-15

    Lymphangioma of the spleen is an extremely rare disease in adults, and performing splenectomy has been considered necessary for its diagnosis and treatment, but the diagnosis of an isolated splenic mass lesion without performing splenectomy is a challenging problem. Herein, we report on a case of multiple splenic lymphangiomas that were found incidentally in a 56-year-old female; these lesions were diagnosed by percutaneous splenic biopsy without splenectomy. We suggest that this approach is a reasonable option for benign looking-appearing splenic tumors because splenectomy and its postsplenectomy complications can be avoided

  16. A Case of Multiple Splenic Lymph angiomas Diagnosed by Percutaneous Needle Biopsy

    International Nuclear Information System (INIS)

    Ki, Seung Seog; Jeong, Sook Hyang; Yoon, Chang Jin; Chang, Se Jung; Choi, Joon Hyuk; Ha, Ji Su; Kim, Soon Je; Lee, Hye Seung

    2007-01-01

    Lymphangioma of the spleen is an extremely rare disease in adults, and performing splenectomy has been considered necessary for its diagnosis and treatment, but the diagnosis of an isolated splenic mass lesion without performing splenectomy is a challenging problem. Herein, we report on a case of multiple splenic lymphangiomas that were found incidentally in a 56-year-old female; these lesions were diagnosed by percutaneous splenic biopsy without splenectomy. We suggest that this approach is a reasonable option for benign looking-appearing splenic tumors because splenectomy and its postsplenectomy complications can be avoided

  17. Digital radiography of crush thoracic trauma in the Sichuan earthquake

    Science.gov (United States)

    Dong, Zhi-Hui; Shao, Heng; Chen, Tian-Wu; Chu, Zhi-Gang; Deng, Wen; Tang, Si-Shi; Chen, Jing; Yang, Zhi-Gang

    2011-01-01

    AIM: To investigate the features of crush thoracic trauma in Sichuan earthquake victims using chest digital radiography (CDR). METHODS: We retrospectively reviewed 772 CDR of 417 females and 355 males who had suffered crush thoracic trauma in the Sichuan earthquake. Patient age ranged from 0.5 to 103 years. CDR was performed between May 12, 2008 and June 7, 2008. We looked for injury to the thoracic cage, pulmonary parenchyma and the pleura. RESULTS: Antero-posterior (AP) and lateral CDR were obtained in 349 patients, the remaining 423 patients underwent only AP CDR. Thoracic cage fractures, pulmonary contusion and pleural injuries were noted in 331 (42.9%; 95% CI: 39.4%-46.4%), 67 and 135 patients, respectively. Of the 256 patients with rib fractures, the mean number of fractured ribs per patient was 3. Rib fractures were mostly distributed from the 3rd through to the 8th ribs and the vast majority involved posterior and lateral locations along the rib. Rib fractures had a significant positive association with non-rib thoracic fractures, pulmonary contusion and pleural injuries (P < 0.001). The number of rib fractures and pulmonary contusions were significant factors associated with patient death. CONCLUSION: Earthquake-related crush thoracic trauma has the potential for multiple fractures. The high number of fractured ribs and pulmonary contusions were significant factors which needed appropriate medical treatment. PMID:22132298

  18. 27 CFR 24.176 - Crushing and fermentation.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Crushing and fermentation..., DEPARTMENT OF THE TREASURY LIQUORS WINE Production of Wine § 24.176 Crushing and fermentation. (a) Natural... fermentation but the density of the juice may not be reduced below 22 degrees Brix. However, if the juice is...

  19. [Comparison of DK crush with classical crush technique with drug-eluting stents for the treatment of coronary bifurcation lesions from DKCRUSH-1 study].

    Science.gov (United States)

    Chen, Shao-liang; Zhang, Jun-jie; Ye, Fei; Chen, Yun-dai; Lü, Shu-zheng; Tan, Huaycheem; Patel, Tejas; Kenji, Kawajiri; Tamari, Israel; Shan, Shou-jie; Zhu, Zhong-sheng; Lin, Song; Tian, Nai-liang; Li, Xiao-bo; Liu, Zhi-zhong; Lee, Michael; Wei, Meng; Xu, Ya-wei; Yuan, Zheng-bai; Qian, Jun; Sun, Xue-wen; Yang, Song; Chen, Jin-guo; He, Ben; Sumit, Suji

    2008-02-01

    To determine independent factors correlated with clinical effects of DK crush and classical crush technique with drug-eluting stents on bifurcation lesions. 311 patients with bifurcation lesions were randomized to classical (C, n = 156) or double kissing (DK) crush (n = 155) stent implantation group. The primary endpoints included major adverse cardiac events (MACE). Final kissing balloon inflation (FKBI) success rate was 76% in C and 100% in DK groups (P DK crush procedure was characterized by lower unsatisfactory FKBI rate (27.6% vs.6.3%, P DK groups (P = 0.01), respectively. Cumulative 8-month MACE was 35.9% in without-FKBI and 19.7% in with-FKBI sub-groups, and 11.4% in DK group (P = 0.02). The incidence of stent thrombosis was 3.2% in C group (5.1% without vs. 1.7% with FKBI) and 1.3% in DK group (P > 0.05). The predictive factors of MACE included minimal side branch stent lumen diameter and lack of DK crush technique. DK crush technique is an alternative of double stenting techniques in terms of improvement of restenosis and clinical outcomes.

  20. Evaluation of crushed ticagrelor tablet doses: recovery following crushing and naso-gastric tube passage ex vivo.

    Science.gov (United States)

    Crean, Barry; Finnie, Cindy; Crosby, Anna

    2013-06-01

    Orally available ticagrelor in combination with low-dose aspirin (75-100 mg/day) is indicated for adult patients with acute coronary syndromes. However, patients with swallowing difficulties may be unable to consume the currently available 90-mg tablet. It is hypothesized that ticagrelor could be given to this patient cohort as a crushed dose administered either orally or via a naso-gastric (NG) tube. To investigate the potential use of crushed ticagrelor tablets (90- and 180-mg doses) for oral dose or NG tube administration. Ticagrelor tablets (90 or 180 mg [two 90-mg tablets]) were prepared to emulate oral and NG tube administration by similar methods. For the oral dose, ticagrelor tablets were crushed using a mortar and pestle and transferred to a dosing cup. 100 mL of water was added to the mortar, stirred, and the contents were transferred to the dosing cup and stirred to form a suspension. At this stage, where the suspension would normally be administered to a patient, it was collected for high performance liquid chromatography (HPLC) analysis. The mortar was then flushed with 100 mL of water, and the contents were again transferred to the dosing cup, stirred, and collected for HPLC analysis. For the NG dose, polyvinylchloride, polyurethane, and silicone size CH10 NG tubes were used. The tablets were crushed using a mortar and pestle, diluted with 50 mL of water, and stirred. At this stage, where the suspension would normally be administered to a patient through an NG tube using a syringe, it was collected for HPLC analysis. The mortar was then flushed with two additional 50 mL aliquots of water and the contents were passed through the NG tube. HPLC analysis examined the recoverability of ticagrelor in each of the dose suspensions and flushes and the stability of the suspension when held in a syringe for up to 2 h. One or two crushed 90-mg ticagrelor tablets, prepared for either oral or NG tube administration, delivers a mean dose of ≥97% of the original

  1. Coke properties in relation to charge preparation techniques. [Selective crushing

    Energy Technology Data Exchange (ETDEWEB)

    Morozov, O S

    1979-01-01

    Selective crushing is essential to obtain the required coke properties, so that in the coarse fractions there is a considerable reduction in the middlings and dirt normally difficult to crush. These are at the same time enriched with vitrinite so that there is an increase in the coal substance as such, reflected in improved caking capacity in the coarse size range. Various methods of selective crushing are employed, including air entrainment mills, fluidised bed systems. Other advantages claimed for selective crushing are the uniform pore distribution and air permeability and also the diminished breakage stress.

  2. MultipleColposcopyJCO

    Science.gov (United States)

    Performing multiple biopsies during a procedure known as colposcopy—visual inspection of the cervix—is more effective than performing only a single biopsy of the worst-appearing area for detecting cervical cancer precursors. This multiple biopsy approach

  3. Characteristics of Crushing Energy and Fractal of Magnetite Ore under Uniaxial Compression

    Science.gov (United States)

    Gao, F.; Gan, D. Q.; Zhang, Y. B.

    2018-03-01

    The crushing mechanism of magnetite ore is a critical theoretical problem on the controlling of energy dissipation and machine crushing quality in ore material processing. Uniaxial crushing tests were carried out to research the deformation mechanism and the laws of the energy evolution, based on which the crushing mechanism of magnetite ore was explored. The compaction stage and plasticity and damage stage are two main compression deformation stages, the main transitional forms from inner damage to fracture are plastic deformation and stick-slip. In the process of crushing, plasticity and damage stage is the key link on energy absorption for that the specimen tends to saturate energy state approaching to the peak stress. The characteristics of specimen deformation and energy dissipation can synthetically reply the state of existed defects inner raw magnetite ore and the damage process during loading period. The fast releasing of elastic energy and the work done by the press machine commonly make raw magnetite ore thoroughly broken after peak stress. Magnetite ore fragments have statistical self-similarity and size threshold of fractal characteristics under uniaxial squeezing crushing. The larger ratio of releasable elastic energy and dissipation energy and the faster energy change rate is the better fractal properties and crushing quality magnetite ore has under uniaxial crushing.

  4. Crushed-salt constitutive model update

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Mellegard, K.D.; Hansen, F.D.

    1998-01-01

    Modifications to the constitutive model used to describe the deformation of crushed salt are presented in this report. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--defined previously but used separately are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. New creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from the shear consolidation tests and a combination of the shear and hydrostatic consolidation tests produced two sets of material parameter values for the model. The change in material parameter values from test group to test group indicates the empirical nature of the model but demonstrates improvement over earlier work with the previous models. Key improvements are the ability to capture lateral strain reversal and better resolve parameter values. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the model to predict the test data, the model appears to capture the creep consolidation behavior of crushed salt quite well

  5. Crushed-salt constitutive model update

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, G.D.; Loken, M.C.; Mellegard, K.D. [RE/SPEC Inc., Rapid City, SD (United States); Hansen, F.D. [Sandia National Labs., Albuquerque, NM (United States)

    1998-01-01

    Modifications to the constitutive model used to describe the deformation of crushed salt are presented in this report. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--defined previously but used separately are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. New creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from the shear consolidation tests and a combination of the shear and hydrostatic consolidation tests produced two sets of material parameter values for the model. The change in material parameter values from test group to test group indicates the empirical nature of the model but demonstrates improvement over earlier work with the previous models. Key improvements are the ability to capture lateral strain reversal and better resolve parameter values. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the model to predict the test data, the model appears to capture the creep consolidation behavior of crushed salt quite well.

  6. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  7. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    proximity to the skin incision, because this tract is also contaminated and must be excised with the surgical specimen. Imaging-guided core needle biopsy is a well-established technique for the diagnosis of bone and soft tissue tumors and tumor-like lesions in specialized orthopedic oncology centers. Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, para spinal area, and pelvis are difficult to target, therefore taking the advantage of C.T. guidance will improve the accuracy of targeting the lesion for biopsy purposes. We can benefit from image intensifiers for targeting limb lesions rather than C.T. guidance. Also sonographic guide can be applied for soft tissue lesions (Figure D, E, F. In soft tissue tumors, the results of percutaneous CNB are relatively inferior compared to open biopsy whereas almost equal results are expected for bony tumors except for low-grade chondrosarcoma. CNB is a safe, minimally invasive, and cost effective technique for the diagnosis of bone lesions if done by an experienced orthopedic oncologic surgeon and be evaluated by an experienced anatomical bone pathologist (1, 3. For soft tissue tumors, CNB results depend on the size of the lesion, its location and amount of tumor necrosis. Guided needle biopsy have become the standard technique in most orthopedic oncologic centers. The accuracy of this method in our center is more than 90% for bone tumors. Cores should be taken in different directions including areas of central necrotic tissues but from a single well planned entrance. The procedure is quick, especially for bone CNB or soft tissue FNA and CNB, and the diagnosis can be achieved within 24 – 48 hours. The material should be sufficient for immunohistochemistry evaluations as well (1-3. Because I have seen 3 cases of tumor implantation at the towel clips puncture site including 2 chondrosarcomas and a case of malignant schowanoma, so I highly suggest that never crush the skin by towel

  8. Dynamic Response and Residual Helmet Liner Crush Using Cadaver Heads and Standard Headforms.

    Science.gov (United States)

    Bonin, S J; Luck, J F; Bass, C R; Gardiner, J C; Onar-Thomas, A; Asfour, S S; Siegmund, G P

    2017-03-01

    Biomechanical headforms are used for helmet certification testing and reconstructing helmeted head impacts; however, their biofidelity and direct applicability to human head and helmet responses remain unclear. Dynamic responses of cadaver heads and three headforms and residual foam liner deformations were compared during motorcycle helmet impacts. Instrumented, helmeted heads/headforms were dropped onto the forehead region against an instrumented flat anvil at 75, 150, and 195 J. Helmets were CT scanned to quantify maximum liner crush depth and crush volume. General linear models were used to quantify the effect of head type and impact energy on linear acceleration, head injury criterion (HIC), force, maximum liner crush depth, and liner crush volume and regression models were used to quantify the relationship between acceleration and both maximum crush depth and crush volume. The cadaver heads generated larger peak accelerations than all three headforms, larger HICs than the International Organization for Standardization (ISO), larger forces than the Hybrid III and ISO, larger maximum crush depth than the ISO, and larger crush volumes than the DOT. These significant differences between the cadaver heads and headforms need to be accounted for when attempting to estimate an impact exposure using a helmet's residual crush depth or volume.

  9. Constitutive behavior of reconsolidating crushed salt

    International Nuclear Information System (INIS)

    Callahan, G.D.; Mellegard, K.D.; Hansen, F.D.

    1998-02-01

    The constitutive model used to describe deformation of crushed salt is presented in this paper. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--are combined to form the basis for the constitutive model governing deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Recently completed creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant (WIPP) and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from shear consolidation tests and a combination of shear and hydrostatic tests produces two sets of material parameter values for the model. Changes in material parameter values from test group to test group indicate the empirical nature of the model but show significant improvement over earlier work. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on fitting statistics and ability of the model to predict test data, the model appears to capture the creep consolidation behavior of crushed salt quite well

  10. Evaluating the Psychological Concomitants of Other-Sex Crush Experiences during Early Adolescence

    Science.gov (United States)

    Bowker, Julie C.; Etkin, Rebecca G.

    2016-01-01

    Very little empirical attention has been paid to other-sex crush experiences during adolescence. As a result, it is not known whether such experiences, which appear to be relatively common, impact psychological adjustment outcomes. This two-wave (3 month interval) longitudinal study of 268 young adolescents (48% girls; M age at Time 1 = 11.84 years) examined the psychological concomitants of other-sex crush experiences (having and being viewed by others as a crush). Anxious-withdrawal and gender were evaluated as moderators. Peer nomination measures at Time 1 assessed both types of crush experiences and mutual friendship involvement, and participants completed self-report measures of loneliness and depressive symptoms at Times 1 and 2. The results from regression analyses revealed significant associations between having an other-sex crush and depressive symptoms at Time 1, after accounting for the effects of mutual friendship. Two interaction effects also revealed that crush status was a risk factor for depressive symptoms at low levels of anxious-withdrawal but a protective factor at high levels. The findings provide the first empirical evidence that other-sex crush experiences are developmentally significant during early adolescence. PMID:26984754

  11. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1980-01-01

    Both crushed (150 to 300 μm) and cored 1.8 mm diameter) samples of SYNROC have been leached with the single-pass continuous-flow leaching equipment. Crushed samples of Cs-hollandite were also leached in a similar experiment. Temperatures used were 25 0 C and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC C were ranked Cs > Sr greater than or equal to Ca > Ba > Zr. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and PNL 76-68 glass beads. Problems encountered when comparing the leaching rates of different waste forms are discussed

  12. Fractal and Morphological Characteristics of Single Marble Particle Crushing in Uniaxial Compression Tests

    Directory of Open Access Journals (Sweden)

    Yidong Wang

    2015-01-01

    Full Text Available Crushing of rock particles is a phenomenon commonly encountered in geotechnical engineering practice. It is however difficult to study the crushing of rock particles using classical theory because the physical structure of the particles is complex and irregular. This paper aims at evaluating fractal and morphological characteristics of single rock particle. A large number of particle crushing tests are conducted on single rock particle. The force-displacement curves and the particle size distributions (PSD of crushed particles are analysed based on particle crushing tests. Particle shape plays an important role in both the micro- and macroscale responses of a granular assembly. The PSD of an assortment of rocks are analysed by fractal methods, and the fractal dimension is obtained. A theoretical formula for particle crushing strength is derived, utilising the fractal model, and a simple method is proposed for predicting the probability of particle survival based on the Weibull statistics. Based on a few physical assumptions, simple equations are derived for determining particle crushing energy. The results of applying these equations are tested against the actual experimental data and prove to be very consistent. Fractal theory is therefore applicable for analysis of particle crushing.

  13. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  14. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  15. Gas adsorption on crushed quartz and basalt. [in vacuum

    Science.gov (United States)

    Barker, C.; Torkelson, B. E.

    1975-01-01

    The new surfaces generated by crushing rocks and minerals adsorb gases. Different gases are adsorbed to different extents so that both the total amount and composition of the released gases are changed. This affects the interpretation of the composition of the gases obtained by vacuum crushing lunar basalts, meteorites and minerals with fluid inclusions.

  16. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  17. Crushing Strength of Ship Structures

    DEFF Research Database (Denmark)

    Cerup-Simonsen, Bo; Abramowicz, W.; Høstgaard-Brene, C.N.S.

    1999-01-01

    The crushing response of ship structures is of primary importance to the designers and practicing engineers concerned with accidental loading and accident reconstruction of marine vehicles. Ship to-ship collisions, ship-harbor infrastructure interaction or ship-offshore structure interaction are ...

  18. Crushing strength of HTGR fuel particles

    International Nuclear Information System (INIS)

    Lackey, W.J.; Stinton, D.P.; Davis, L.E.; Beatty, R.L.

    1976-01-01

    The whole-particle crushing strengths of High-Temperature Gas-Cooled Reactor fertile and fissile coated particles were measured and correlated with fabrication procedures. The crushing strength of Biso-coated fertile particles was increased by the following factors: (1) increasing the outer coating thickness by 10 μm increased strengths by 0.3 lb (1.3 N) for annealed particles and by 0.5 lb (2.2 N) for unannealed particles. (2) An 1800 0 C postcoating anneal increased strengths by 1 lb (4.4 N) for particles with thick outer coatings and by 2 lb (8.9 N) for particles having thin coatings. (3) Increasing the inner coating density by 0.1 g/cm 3 increased strength by 0.6 lb (2.7 N). The crushing strength of Triso-coated fissile particles was proportional to the thickness of the SiC coatings, and strength decreased on annealing by about 0.2 lb (0.9 N) when a porous plate was used to distribute the coating gas and by about 1.5 lb (6.7 N) when a conical gas distributor was used. The strengths of fertile and fissile coated particles as well as uncoated kernels appear adequate to allow fuel fabrication without excessive particle damage

  19. The effect of proposed crush tests on transport containers

    International Nuclear Information System (INIS)

    1984-09-01

    Crush tests were performed on two AECL F112 packaging specimens, two simulated AECL-CRNL 4H packaging specimens, and on empty steel drums. The 9 m drop test was carried out on two simulated AECL-CRNL 4H packaging specimens for comparison with the effects of the crush test. The tests were filmed using high speed photography and 35mm still photographs

  20. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  1. Reduced Renshaw Recurrent Inhibition after Neonatal Sciatic Nerve Crush in Rats

    Directory of Open Access Journals (Sweden)

    Liang Shu

    2014-01-01

    Full Text Available Renshaw recurrent inhibition (RI plays an important gated role in spinal motion circuit. Peripheral nerve injury is a common disease in clinic. Our current research was designed to investigate the change of the recurrent inhibitory function in the spinal cord after the peripheral nerve crush injury in neonatal rat. Sciatic nerve crush was performed on 5-day-old rat puppies and the recurrent inhibition between lateral gastrocnemius-soleus (LG-S and medial gastrocnemius (MG motor pools was assessed by conditioning monosynaptic reflexes (MSR elicited from the sectioned dorsal roots and recorded either from the LG-S and MG nerves by antidromic stimulation of the synergist muscle nerve. Our results demonstrated that the MSR recorded from both LG-S or MG nerves had larger amplitude and longer latency after neonatal sciatic nerve crush. The RI in both LG-S and MG motoneuron pools was significantly reduced to virtual loss (15–20% of the normal RI size even after a long recovery period upto 30 weeks after nerve crush. Further, the degree of the RI reduction after tibial nerve crush was much less than that after sciatic nerve crush indicatig that the neuron-muscle disconnection time is vital to the recovery of the spinal neuronal circuit function during reinnervation. In addition, sciatic nerve crush injury did not cause any spinal motor neuron loss but severally damaged peripheral muscle structure and function. In conclusion, our results suggest that peripheral nerve injury during neonatal early development period would cause a more sever spinal cord inhibitory circuit damage, particularly to the Renshaw recurrent inhibition pathway, which might be the target of neuroregeneration therapy.

  2. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  3. Preparation-induced errors in EPR dosimetry of enamel: pre- and post-crushing sensitivity

    International Nuclear Information System (INIS)

    Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1996-01-01

    Errors in dose estimation as a function of grain size for tooth enamel has been previously shown for beta irradiation after crushing. We tested the effect of gamma radiation applied to specimens before and after crushing. We extend the previous work in that we found that post-crushing irradiation altered the slope of the dose-response curve of the hydroxyapatite signal and produced a grain-size dependent offset. No changes in the slope of the dose-response curve were seen in enamel caps irradiated before crushing

  4. Assessment of crushed-recycled glass as filter media for drinking water treatment

    International Nuclear Information System (INIS)

    Rutledge, S.O.; Fahie, C.; Gagnon, G.A.

    2002-01-01

    The objective of this project was to evaluate the performance of a pressure filter utilizing crushed glass as the filter media. The performance of the crushed glass filter was compared to that of a sand filter. The research was conducted in Orangedale, Nova Scotia, which is a small community of with a population of approximately 500. Orangedale is located on the south shore of Bras d'Or Lakes and feeds into Miller Pond, which serves as the source the of drinking water. The Orangedale treatment plant produces an average daily flow of 35 m3/d (6.4-gpm). The treatment plant consists of coagulation (sodium aluminate and polyaluminum chloride), flocculation, dissolved air flotation (DAF), disinfection with sodium hypochlorite and dual-media filtration with anthracite and sand. In general, the particle removal capabilities of the crushed glass filter were slightly poorer than that of a sand filter, as quantified in a field application in the community of Orangedale, Nova Scotia. It was found that the crushed glass used in this project had a higher angularity and slightly higher uniformity coefficient. During initial start-up the performance of the crushed glass filter was more variable and appeared to improve as the glass began to wear. After six-months of use the crushed glass filter was able to produce a very consistent filter effluent that was only slightly greater than the silica sand filter. After six-months of use, the sand filter achieved a 1.6 log-removal of particles with diameters greater than 2 μm; whereas the crushed glass filter achieved a 1.4 log removal for the similar particle size range. The observed removal performance was particularly encouraging given that the sand used had properties that were consistent with the standards set by the American Water Works Association. The crushed glass filter media was initially sieved and washed, but had no other pre-treatment preparation. Thus the application of crushed glass shows considerable promise as filter

  5. Diagnosis of multiple myeloma on based the material obtained by fine needle aspiration biopsy of the lungs

    Directory of Open Access Journals (Sweden)

    Bokun Radojka

    2004-01-01

    Full Text Available The patient presented in this paper was admitted to the hospital for the evaluation of radiologically revealed shadow in both lungs. In the course of diagnostic procedures, fine needle aspiration biopsy of the intrathoracic mass was performed. Cytologic analysis of the smear was performed because of clinical suspicion of plasma cell proliferative disease that was confirmed by bone marrow aspiration. Thus, the cytologic finding of intrathoracic lesion preceded the diagnosis of multiple myeloma.

  6. Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.

    Science.gov (United States)

    Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen

    2018-06-01

    There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.

  7. Investigation on Compressive Strength of Special Concrete made with Crushed Waste Glass

    Directory of Open Access Journals (Sweden)

    Mohd Sani Mohd Syahrul Hisyam

    2015-01-01

    Full Text Available Special concrete is the type of concrete that produced by using waste material or using unusual techniques/method of preparation. Special concrete made with waste material is becoming popular in a construction site. This is because the special concrete is selected due to quality, integrity, economic factor and environmental factor. The waste glass is selected as an additional material to provide a good in compressive strength value. The compressive strength is the importance of mechanical properties of concrete and typically the concrete is sustained and stiffed in compression load. The significant issue to utilize the waste glass from the automotive windscreen is to improve the strength of concrete. The waste glass is crushed to become 5 mm size and recognised as crushed waste glass that be used in concrete as additional material. The main objective of the study is to determine the appropriate percentage of crushed waste glass in concrete grade, 30 in order to enhance the compressive strength. There are four mixes of concrete that contained of crushed waste glass with percentage of 2 %, 4 %, 6 % and 8 % and one control mix with 0 % of crushed waste glass. As the result, crushed waste glass with an additional 4 % in concrete is reported having a higher value of compressive strength in early and mature stage. In addition, if the percentage of crushed glass wastes in concrete increases and it leads to a reduction in the workability of concrete.

  8. Research for the development of the crushed sand (II)

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Whan; Kang, Sun Duck; Min, Jeong Sik; Synn, Joong Ho; Park, Chan [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The sand obtained from river is not sufficient in amount for the demand of construction industry. The production of sand from sea and mountain is rapidly increasing for the substitution of the river sand. The industry of the crushed sand has recently been bricked for the above. Crushing, classification and dewatering are the main processes in the crushed sand production. This report concentrates the improvement of classification technology and the quality of ready mixed concrete. Air separator with testing size for the classification in the process of dry system was developed by the Yeung Nam university. This plant has the excellent efficiency for the collection of fine powder, but needs the improvement for separating function. The collection efficiency of the testing size air separator is reached to 99% in the condition of high revolution and low feeding speed. The classification efficiency is checked about 50% maximum in the condition of 200 rpm and dry sample. Energy saving test was carried out in the production process of the dry system with the rock samples of 14-17% of water content. The classification efficiency for dewatering sample passed the heating process was analysed 91.5%. But that for high water content sample skipped the heating process was analysed more or less 77%. Even though the heating process causes the classification efficiency being high, the energy consumption can also cause the price of the crushed sand high. Water content of sample as the effective element for the optimization of classification efficiency and energy saving should be studied next year. The quality of crushed sand in the mixing design. The test was carried out with the various content in mixing, the strength of ready mixed concrete has the maximum for the mould with 50-60% content of crushed sand. This strength is higher by 5-30% than 30% content and by 20-32% than 0% content, which means that the industry has the possibility of progress. (author). 10 refs., 31 tabs., 49

  9. Assessment of Clinical Practices for Crushing Medication in Geriatric Units.

    Science.gov (United States)

    Fodil, M; Nghiem, D; Colas, M; Bourry, S; Poisson-Salomon, A-S; Rezigue, H; Trivalle, C

    2017-01-01

    To assess the modification of the form of medication and evaluate staff observance of good clinical practices. One-day assessment of clinical practices. 17 geriatrics units in the 3 Teaching Hospitals of Paris-Sud (APHP), France. Elderly in-patients with difficulties swallowing capsules and tablets. Assessment of target-patient prescriptions and direct observation of nurses' medical rounds. 155/526 in-patients (29.5%) were unable to swallow tablets or capsules: 98 (40.3%) in long-term care, 46 patients (23.8%) in the rehabilitation unit and 11 (12.2%) in the acute care unit (p = .005). In thirty-nine (27.3%) of the 143 prescriptions studied all tablets were safe to crush and all capsules were safe to open. In 104 cases, at least one medication could not be safely modified, including 26 cases (18.2%) in which none of the prescribed drugs were safe to crush or open. In 48.2% of the 110 medications that were crushed, crushing was forbidden, and presented a potential threat in 12.7% of cases or a reduced efficacy in 8.2% of cases. Crushing methods were rarely appropriate: no specific protective equipment was used (81.8%), crushing equipment was shared between patients without cleaning (95.1%), medications were spilled or lost (69.9%). The method of administration was appropriate (water, jellified water) in 25% of the cases, questionable (soup, coffee, compote, juice, cream) in 55% of the cases and unacceptable (laxative) in 21% of the cases. Management of drug prescriptions in patients with swallowing difficulties is not optimal, and may even have iatrogenic effects. In this study, 12.7% of the modifications of the drug form could have been harmful. Doctors, pharmacists and nurses need to reevaluate their practices.

  10. Effect of crushing temperature on virgin olive oil quality and composition

    Directory of Open Access Journals (Sweden)

    Ö. Kula

    2018-03-01

    Full Text Available The objective of the current study was to assess the influence of a modified crushing process and kneading operation on the quality parameters, volatile compounds, and the fatty acid and sterol profiles of virgin olive oil from the Edremit yaglik variety. In the study, olive oil samples were produced in two different processes. The first one was produced without malaxation and the second one was produced with the malaxing process. During crushing, the effect of different temperatures was tested. The results demonstrate that different crushing temperatures generally did not affect the amount of free fatty acids, or peroxide value. Total phenol contents were positively affected by the additional malaxation process. Fatty acids and sterol composition were not significantly altered at different crushing temperatures or during the subsequent malaxation application. PCA enabled a clear classification of the oils obtained from different processing techniques.

  11. Physical, mechanical and thermal properties of Crushed Sand Concrete containing Rubber Waste

    Directory of Open Access Journals (Sweden)

    Mohamed Guendouz

    2018-01-01

    Full Text Available Over the past twenty years, the rubber wastes are an important part of municipal solid waste. This work focuses on the recycling of rubber waste, specifically rubber waste of used shoes discharged into the nature and added in the mass of crushed sand concrete with percentage (10%, 20%, 30% and 40%. The physical (workability, fresh density, mechanical (compressive and flexural strength and thermal (thermal conductivity of different crushed sand concrete made are analyzed and compared to the respective controls. The use of rubber waste in crushed sand concrete contributes to reduce the bulk density and performance of sand concrete. Nevertheless, the use of rubber aggregate leads to a significant reduction in thermal conductivity, which improves the thermal insulation of crushed sand concrete.

  12. Evaluation of constitutive models for crushed salt

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Hurtado, L.D.; Hansen, F.D.

    1996-01-01

    Three constitutive models are recommended as candidates for describing the deformation of crushed salt. These models are generalized to three-dimensional states of stress to include the effects of mean and deviatoric stress and modified to include effects of temperature, grain size, and moisture content. A database including hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant (WIPP) and southeastern New Mexico salt is used to determine material parameters for the models. To evaluate the capability of the models, parameter values obtained from fitting the complete database are used to predict the individual tests. Finite element calculations of a WIPP shaft with emplaced crushed salt demonstrate the model predictions

  13. The effect of motorcycle helmet fit on estimating head impact kinematics from residual liner crush.

    Science.gov (United States)

    Bonin, Stephanie J; Gardiner, John C; Onar-Thomas, Arzu; Asfour, Shihab S; Siegmund, Gunter P

    2017-09-01

    Proper helmet fit is important for optimizing head protection during an impact, yet many motorcyclists wear helmets that do not properly fit their heads. The goals of this study are i) to quantify how a mismatch in headform size and motorcycle helmet size affects headform peak acceleration and head injury criteria (HIC), and ii) to determine if peak acceleration, HIC, and impact speed can be estimated from the foam liner's maximum residual crush depth or residual crush volume. Shorty-style helmets (4 sizes of a single model) were tested on instrumented headforms (4 sizes) during linear impacts between 2.0 and 10.5m/s to the forehead region. Helmets were CT scanned to quantify residual crush depth and volume. Separate linear regression models were used to quantify how the response variables (peak acceleration (g), HIC, and impact speed (m/s)) were related to the predictor variables (maximum crush depth (mm), crush volume (cm 3 ), and the difference in circumference between the helmet and headform (cm)). Overall, we found that increasingly oversized helmets reduced peak headform acceleration and HIC for a given impact speed for maximum residual crush depths less than 7.9mm and residual crush volume less than 40cm 3 . Below these levels of residual crush, we found that peak headform acceleration, HIC, and impact speed can be estimated from a helmet's residual crush. Above these crush thresholds, large variations in headform kinematics are present, possibly related to densification of the foam liner during the impact. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Diffusion in the pore water of compacted crushed salt

    Energy Technology Data Exchange (ETDEWEB)

    Fluegge, Judith; Herr, Sebastian; Lauke, Thomas; Meleshyn, Artur; Miehe, Ruediger; Ruebel, Andre

    2016-07-15

    Diffusion of dissolved radionuclides in the pore water of compacted crushed salt in the long-term is the most relevant process for the release of radionuclides from a dedicated repository for high-level waste in a salt formation as has been shown in latest safety assessments and research projects /BUH 16/. So far, diffusion coefficients for free water have been applied for the diffusion in pore water in models for long-term safety assessments. This conservative assumption was used, because data on the diffusion coefficient of dissolved substances in crushed salt have been missing. Furthermore, the diffusion coefficient in the pore water was assumed to be constant and independent from the degree of compaction of the crushed salt. The work presented in this report was intended to contribute to fill this gap of knowledge about how the diffusion of radionuclides takes place in the compacted backfill of a repository in salt. For the first time, the pore diffusion coefficient as well as its dependence on the porosity of the crushed salt was determined experimentally by means of through-diffusion experiments using caesium as tracer. The results achieved in this project suggest that the diffusion in compacted crushed salt is not fully comparable to that in a homogeneous, temporally stable porous medium like sand or clay. The results obtained from four diffusion experiments show a remarkably different behaviour and all yield unique concentration versus time plots which includes highly temporal variable tracer fluxes with even full interruptions of the flux for longer periods of time. This effect cannot be explained by assuming a tracer transport by diffusion in a temporarily invariant pore space and / or under temporally invariant experimental conditions. From our point of view, a restructuring of the pore space seems to lead to closed areas of pore water in the sample which may open up again after some time, leading to a variable pore space and hence variable diffusive

  15. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Safety and health in the stone crushing industry : a practical manual for preventing accidents preserving health and keeping a company profitable. Études. Abstract for oral presentation : addressing health risk of communities residing close to stone quarrying and crushing unit using ecohealth framework in Central India.

  16. 49 CFR 587.15 - Verification of aluminum honeycomb crush strength.

    Science.gov (United States)

    2010-10-01

    ... analog or digital form for each sample tested. If analog data are collected, a means of converting the data to digital data must be made available. All digital data are collected at a rate consistent with... all data prior to 6.4 mm (0.25 in) of crush and after 16.5 mm (0.65 in) of crush. Divide the remaining...

  17. Thermal conductivity of crushed salt

    International Nuclear Information System (INIS)

    Kuehn, K.

    Heat transfer through an annular space filled with crushed salt depends primarily on the thermal conductivity, lambda, of the material. This report gives a formula with which lambda can be computed. The formula includes two quantities that can be influenced through screening of the salt smalls: the porosity, psi, and the fraction, alpha, of the more highly resistive heat-flow paths. The report computes and presents graphically the thermal conductivities for various values of psi and alpha. Heat-transfer properties are computed and compared for an annular space filled with crushed salt and for an air gap. The comparison shows that the properties of the annular space are larger only up to a certain temperature, because the properties of the air gap increase exponentially while those f the annular space increase only in an approximately linear way. Experimental results from Project Salt Vault in the U.S. are in good agreement with the calculations performed. Trials in Temperature Experimental Field 2 at the Asse II salt mine will provide an additional check on the calculations. 3 figures, 3 tables

  18. Crush Can Behaviour as an Energy Absorber in a Frontal Impact

    International Nuclear Information System (INIS)

    Bhuyan, Atanu; Ganilova, Olga

    2012-01-01

    The work presented is devoted to the investigation of a state-of-the-art technological solution for the design of a crush-can characterized by optimal energy absorbing properties. The work is focused on the theoretical background of the square tubes, circular tubes and inverbucktube performance under impact with the purpose of design of a novel optimized structure. The main system under consideration is based on the patent US 2008/0185851 A1 and includes a base flange with elongated crush boxes and back straps for stabilization of the crush boxes with the purpose of improvement of the energy-absorbing functionality. The modelling of this system is carried out applying both a theoretical approach and finite element analysis concentrating on the energy absorbing abilities of the crumple zones. The optimization process is validated under dynamic and quasi-static loading conditions whilst considering various modes of deformation and stress distribution along the tubular components. Energy absorbing behaviour of the crush-cans is studied concentrating on their geometrical properties and their diamond or concertina modes of deformation. Moreover, structures made of different materials, steel, aluminium and polymer composites are considered for the material effect analysis and optimization through their combination. Optimization of the crush-can behaviour is done within the limits of the frontal impact scenario with the purpose of improvement of the structural performance in the Euro NCAP tests.

  19. Crush Can Behaviour as an Energy Absorber in a Frontal Impact

    Science.gov (United States)

    Bhuyan, Atanu; Ganilova, Olga

    2012-08-01

    The work presented is devoted to the investigation of a state-of-the-art technological solution for the design of a crush-can characterized by optimal energy absorbing properties. The work is focused on the theoretical background of the square tubes, circular tubes and inverbucktube performance under impact with the purpose of design of a novel optimized structure. The main system under consideration is based on the patent US 2008/0185851 A1 and includes a base flange with elongated crush boxes and back straps for stabilization of the crush boxes with the purpose of improvement of the energy-absorbing functionality. The modelling of this system is carried out applying both a theoretical approach and finite element analysis concentrating on the energy absorbing abilities of the crumple zones. The optimization process is validated under dynamic and quasi-static loading conditions whilst considering various modes of deformation and stress distribution along the tubular components. Energy absorbing behaviour of the crush-cans is studied concentrating on their geometrical properties and their diamond or concertina modes of deformation. Moreover, structures made of different materials, steel, aluminium and polymer composites are considered for the material effect analysis and optimization through their combination. Optimization of the crush-can behaviour is done within the limits of the frontal impact scenario with the purpose of improvement of the structural performance in the Euro NCAP tests.

  20. Utilization of crushed clay brick in cellular concrete production

    Directory of Open Access Journals (Sweden)

    Ali A. Aliabdo

    2014-03-01

    Full Text Available The main objective of this research program is to study the effect of using crushed clay brick as an alternative aggregate in aerated concrete. Two series of mixtures were designed to investigate the physico-mechanical properties and micro-structural analysis of autoclave aerated concrete and foamed concrete, respectively. In each series, natural sand was replaced with crushed clay brick aggregate. In both series results showed a significant reduction in unit weight, thermal conductivity and sound attenuation coefficient while porosity has increased. Improvement on compressive strength of autoclave aerated concrete was observed at a percentage of 25% and 50% replacement, while in foamed concrete compressive strength gradually decreased by increasing crushed clay brick aggregate content. A comparatively uniform distribution of pore in case of foamed concrete with natural sand was observed by scanning electron microscope, while the pores were connected mostly and irregularly for mixes containing a percentage higher than 25% clay brick aggregate.

  1. The influence of heavy mineral crushing in analysis of U mobile

    International Nuclear Information System (INIS)

    Tatang-Suherman

    2000-01-01

    The aim of experiments is to find out the influence of sample crushing in analysis of U mobile it was compared between U content of crusher and uncrushed samples. The uncrushed samples including the grain size of minus 40, 60, 80 and 100 mesh, since while the uncrushed sample was minus 60, 80, 100, 120 and 150 mesh. The U analysis was done by comparing with fluorescence of standard sample using Fluorimetric determination. The result of uncrushed samples have a same concentration in all of grain fractions and the crushed samples have a higher concentration on the smallest of grain fractions. The content of U mobile from crushed sample have significant result at - 120 mesh to - 150 mesh

  2. Bronchoscopic intratumoral injection of tranexamic acid to prevent excessive bleeding during multiple forceps biopsies of lesions with a high risk of bleeding: a prospective case series

    International Nuclear Information System (INIS)

    Zamani, Adil

    2014-01-01

    Significant bleeding may occur following endobronchial forceps biopsy or brushing of necrotic or hypervascular tumors in the airways. In some cases, methods such as endobronchial instillation of iced saline lavage and epinephrine may fail to control bleeding. The present study evaluated the efficacy and safety of a new bronchoscopic technique using intratumoral injection of tranexamic acid (IIT) for control of bleeding during forceps biopsy in patients with endobronchial tumors with a high risk of bleeding. The study was a prospective case series carried out in a single center. Bronchoscopic IIT was performed in those patients who had endoscopically visible tumoral lesions with persistent active bleeding following the first attempt at bronchoscopic sampling. Tranexamic acid (TEA) was injected through a 22-gauge Wang cytology needle into the lesion in nominal doses of 250–500 mg. After 2–3 minutes, multiple forceps biopsy specimens were obtained from the lesion. Of the 57 consecutive patients included in the study, 20 patients (35.1%) underwent bronchoscopic IIT. The first attempt in 18 patients was endobronchial forceps biopsy (EBB), and because of a high risk of bleeding, the first attempt for the remaining two patients, who were on continuous dual antiplatelet therapy (aspirin and clopidogrel), employed endobronchial needle aspiration (EBNA) as a precautionary measure. Following IIT, subsequent specimens were obtained using EBB in all patients. Multiple forceps biopsy specimens (3–10) were obtained from the lesions (8 necrotic and 12 hypervascular) without incurring active bleeding. The following histopathologic diagnoses were made: squamous cell carcinoma (n = 14), adenocarcinoma (n = 2), small-cell lung cancer (n = 3), and malignant mesenchymal tumor (n = 1). No side effects of TEA were observed. Bronchoscopic IIT is a useful and safe technique for controlling significant bleeding from a forceps biopsy procedure and can be considered as a pre-biopsy

  3. Rock Crushing Using Microwave Pre-Treatment

    KAUST Repository

    Kim, Seunghee; Santamarina, Carlos

    2016-01-01

    Crushing and grinding are primary contributors to a high energy demand in the mining industry, yet, both are surprisingly inefficient processes, often with efficiencies as low as 1%. We analyze size reductions during crushing and grinding operations and explore the potential of multiplying internal weaknesses in rock materials by non-mechanical means. In particular, when rock blocks (wet or even dry if polycrystalline) are exposed to microwaves, internal cracks can develop along grain boundaries via differential thermal expansion between grains and volumetric thermal expansion of water in pores. Brazilian tests conducted on granite and cement mortar specimens show that the tensile strength decreases proportional to the duration of microwave treatment. Thermal changes, excessive fluid pressure buildup and induced stresses are analyzed in the context of hydro-Thermo-mechanically coupled processes. Results confirm that both differential thermal expansion of mineral grains and volumetric thermal expansion of water can generate cracks upon microwave exposure. Optimal conditions are suggested to lower the combined consumption of electric and mechanical energy.

  4. Rock Crushing Using Microwave Pre-Treatment

    KAUST Repository

    Kim, Seunghee

    2016-08-11

    Crushing and grinding are primary contributors to a high energy demand in the mining industry, yet, both are surprisingly inefficient processes, often with efficiencies as low as 1%. We analyze size reductions during crushing and grinding operations and explore the potential of multiplying internal weaknesses in rock materials by non-mechanical means. In particular, when rock blocks (wet or even dry if polycrystalline) are exposed to microwaves, internal cracks can develop along grain boundaries via differential thermal expansion between grains and volumetric thermal expansion of water in pores. Brazilian tests conducted on granite and cement mortar specimens show that the tensile strength decreases proportional to the duration of microwave treatment. Thermal changes, excessive fluid pressure buildup and induced stresses are analyzed in the context of hydro-Thermo-mechanically coupled processes. Results confirm that both differential thermal expansion of mineral grains and volumetric thermal expansion of water can generate cracks upon microwave exposure. Optimal conditions are suggested to lower the combined consumption of electric and mechanical energy.

  5. Carpal tunnel syndrome and the "double crush" hypothesis: a review and implications for chiropractic

    Directory of Open Access Journals (Sweden)

    Russell Brent S

    2008-04-01

    Full Text Available Abstract Upton and McComas claimed that most patients with carpal tunnel syndrome not only have compressive lesions at the wrist, but also show evidence of damage to cervical nerve roots. This "double crush" hypothesis has gained some popularity among chiropractors because it seems to provide a rationale for adjusting the cervical spine in treating carpal tunnel syndrome. Here I examine use of the concept by chiropractors, summarize findings from the literature, and critique several studies aimed at supporting or refuting the hypothesis. Although the hypothesis also has been applied to nerve compressions other than those leading to carpal tunnel syndrome, this discussion mainly examines the original application – "double crush" involving both cervical spinal nerve roots and the carpal tunnel. I consider several categories: experiments to create double crush syndrome in animals, case reports, literature reviews, and alternatives to the original hypothesis. A significant percentage of patients with carpal tunnel syndrome also have neck pain or cervical nerve root compression, but the relationship has not been definitively explained. The original hypothesis remains controversial and is probably not valid, at least for sensory disturbances, in carpal tunnel syndrome. However, even if the original hypothesis is importantly flawed, evaluation of multiple sites still may be valuable. The chiropractic profession should develop theoretical models to relate cervical dysfunction to carpal tunnel syndrome, and might incorporate some alternatives to the original hypothesis. I intend this review as a starting point for practitioners, educators, and students wishing to advance chiropractic concepts in this area.

  6. [Hygienic assessment of metal-lurgical slag crushed stone for its use in road-building].

    Science.gov (United States)

    Tikhomirov, Iu P; Ippolitova, V P; Bezrokov, M E

    2010-01-01

    The increasing amount of industrial waste generates a need for its use as recycled materials. The paper presents the results of hygienic assessment of metallurgic slag crushed stone to be added to natural materials in highway building. The research program has included the measurement of content of water-soluble forms of metals, the evaluation of the acute toxicity of waste after oral administration to mice and rats, the study of the toxicity of waste by biotesting and the activity of natural radionuclides. The slag crushed stone virtually lacks water-soluble elements when it contains a high level of bulk forms of metals. According to acute toxicity for warm-blooded animals, the slag crushed stone belongs to Hazard Class IV by GOST 12.1.007-76 (low hazard substances). The biotesting on hydrocoles, the slag crushed stone is also referred to as Class IV (low hazard substances). In terms of the level of natural radionuclides, the slag crushed stone poses no hazard to the environment. The performed studies give grounds to recommend metallurgical slag crushed stone to be added to natural materials for highway building.

  7. CRUSH1: a simplified computer program for impact analysis of radioactive material transport casks

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, Takeshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-07-01

    In drop impact analyses for radioactive transport casks, it has become possible to perform them in detail by using interaction evaluation, computer programs, such as DYNA2D, DYNA3D, PISCES and HONDO. However, the considerable cost and computer time are necessitated to perform analyses by these programs. To meet the above requirements, a simplified computer program CRUSH1 has been developed. The CRUSH1 is a static calculation computer program capable of evaluating the maximum acceleration of cask bodies and the maximum deformation of shock absorbers using an Uniaxial Displacement Method (UDM). The CRUSH1 is a revised version of the CRUSH. Main revisions of the computer program are as follows; (1) not only main frame computer but also work stations (OS UNIX) and personal computer (OS Windows 3.1 or Windows NT) are available for use of the CRUSH1 and (2) input data set are revised. In the paper, brief illustration of calculation method using UDM is presented. The second section presents comparisons between UDM and the detailed method. The third section provides a use`s guide for CRUSH1. (author)

  8. CRUSH1: a simplified computer program for impact analysis of radioactive material transport casks

    International Nuclear Information System (INIS)

    Ikushima, Takeshi

    1996-07-01

    In drop impact analyses for radioactive transport casks, it has become possible to perform them in detail by using interaction evaluation, computer programs, such as DYNA2D, DYNA3D, PISCES and HONDO. However, the considerable cost and computer time are necessitated to perform analyses by these programs. To meet the above requirements, a simplified computer program CRUSH1 has been developed. The CRUSH1 is a static calculation computer program capable of evaluating the maximum acceleration of cask bodies and the maximum deformation of shock absorbers using an Uniaxial Displacement Method (UDM). The CRUSH1 is a revised version of the CRUSH. Main revisions of the computer program are as follows; (1) not only main frame computer but also work stations (OS UNIX) and personal computer (OS Windows 3.1 or Windows NT) are available for use of the CRUSH1 and (2) input data set are revised. In the paper, brief illustration of calculation method using UDM is presented. The second section presents comparisons between UDM and the detailed method. The third section provides a use's guide for CRUSH1. (author)

  9. Effect of Raw Crushed Garlic (Allium sativum L.) on Components of Metabolic Syndrome.

    Science.gov (United States)

    Choudhary, Prema Ram; Jani, Rameshchandra D; Sharma, Megh Shyam

    2017-09-28

    Metabolic syndrome consists of a group of risk factors characterized by abdominal obesity, hypertension, atherogenic dyslipidemia, hyperglycemia, and prothrombotic and proinflammatory conditions. Raw garlic homogenate has been reported to reduce serum lipid levels in animal model; however, no precise studies have been performed to evaluate the effect of raw crushed garlic (Allium sativum L.) on components of metabolic syndrome. Therefore, the present study was designed to investigate the effect of raw crushed garlic on components of metabolic syndrome. A total of 40 metabolic syndrome patients were randomly selected from the diabetic center of SP Medical College, Bikaner, Rajasthan, India. They underwent treatment with 100 mg/kg body weight raw crushed garlic 2 times a day with standard diet for 4 weeks; their anthropometric and serum biochemical variables were measured at both the beginning and the end of the study. Statistical analysis was performed using IBM SPSS version 20, and Student's paired "t" test was used to compare variables before and after treatment with garlic preparation. Raw crushed garlic significantly reduced components of metabolic syndrome including waist circumference (p .05) of patients with metabolic syndrome after consumption of raw crushed garlic for 4 weeks. Raw crushed garlic has beneficial effects on components of metabolic syndrome; therefore, it can be used as an accompanying remedy for prevention and treatment of patients with metabolic syndrome.

  10. Strain-rate effect on initial crush stress of irregular honeycomb under dynamic loading and its deformation mechanism

    Science.gov (United States)

    Wang, Peng; Zheng, Zhijun; Liao, Shenfei; Yu, Jilin

    2018-02-01

    The seemingly contradictory understandings of the initial crush stress of cellular materials under dynamic loadings exist in the literature, and a comprehensive analysis of this issue is carried out with using direct information of local stress and strain. Local stress/strain calculation methods are applied to determine the initial crush stresses and the strain rates at initial crush from a cell-based finite element model of irregular honeycomb under dynamic loadings. The initial crush stress under constant-velocity compression is identical to the quasi-static one, but less than the one under direct impact, i.e. the initial crush stresses under different dynamic loadings could be very different even though there is no strain-rate effect of matrix material. A power-law relation between the initial crush stress and the strain rate is explored to describe the strain-rate effect on the initial crush stress of irregular honeycomb when the local strain rate exceeds a critical value, below which there is no strain-rate effect of irregular honeycomb. Deformation mechanisms of the initial crush behavior under dynamic loadings are also explored. The deformation modes of the initial crush region in the front of plastic compaction wave are different under different dynamic loadings.

  11. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1982-01-01

    Both crushed (150- to 300- μm) and cored (1,8- mm-diam) samples of SYNROC have been leached with single-pass continuous-flow leaching equipment. Crushed samples of cesium-hollandite were also leached in a similar experiment. Temperatures used were 25 0 and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC-C were ranked cesium > strontium greater than or equal to calcium > barium > zirconium. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and Pacific Northwest Laboratory 76-68 glass beads. This comparison depends on how the surface areas are determined for each sample. Based on geometric surface areas for SYNROC cores and glass beads, cesium leach rates from SYNROC compare well with both sodium and neptunium leached from the glass. The other elements leached from SYNROC are lower than sodium and neptunium leached from glass. They also vary for each element, while glass shows nearly the same leach rate for both sodium and neptunium

  12. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1981-01-01

    Both crushed (150 to 300 μm) and cored (1.8 mm diameter) samples of SYNROC have been leached with the single-pass continuous-flow leaching equipment. Crushed samples of Cs-hollandite were also leached in a similar experiment. Temperatures used were 25 and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC C were ranked Cs > Sr greater than or equal to Ca > Ba > Zr. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and PNL 76-68 glass beads. This comparison depends on how the surface areas are determined for each sample. Based on geometric surface areas for SYNROC cores and glass beads Cs leach rates from SYNROC compare well with both Na and Np leached from the glass. The other elements leached from SYNROC are lower than Na and Np leached from glass. They also vary for each element while glass shows nearly the same leach rate for both Na and Np

  13. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  14. Seismic tipping analysis of a spent nuclear fuel shipping cask sitting on a crush pad

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1998-04-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of an accidentally dropped spent nuclear fuel shipping cask into a 44 ft. deep cask unloading pool. Conventional analysis techniques available for evaluating a cask for tipping due to lateral seismic forces assume that the cask rests on a rigid surface. In this analysis, the cask (110 tons) sits on a stainless steel encased (0.25 in. top plate), polyurethane foam (4 ft. thick) crush pad. As the cask tends to rock due to horizontal seismic forces, the contact area between the cask and the crush pad is reduced, increasing the bearing stress, and causing the pivoting corner of the cask to depress into the crush pad. As the crush pad depresses under the cask corner, the pivot point shifts from the corner toward the cask center, which facilitates rocking and potential tipping of the cask. Subsequent rocking of the cask may deepen the depression, further contributing to the likelihood of cask tip over. However, as the depression is created, the crush pad is absorbing energy from the rocking cask. Potential tip over of the cask was evaluated by performing a non-linear, dynamic, finite element analysis with acceleration time history input. This time history analysis captured the effect of a deforming crush pad, and also eliminated conservatisms of the conventional approaches. For comparison purposes, this analysis was also performed with the cask sitting on a solid stainless steel crush pad. Results indicate that the conventional methods are quite conservative relative to the more exacting time history analysis. They also indicate that the rocking motion is less on the foam crush pad than on the solid stainless steel pad

  15. Calculation of density and permeability of compacted crushed salt within an engineered shaft sealing system

    International Nuclear Information System (INIS)

    Loken, M.; Statham, W.

    1997-01-01

    Crushed salt from the host Salado Formation is proposed as a sealing material in one component of a multicomponent seal system design for the shafts of the Waste Isolation Pilot Plant (WIPP), a mined geological repository for storage and disposal of transuranic radioactive wastes located near Carlsbad, New Mexico. The crushed salt will be compacted and placed at a density approaching 90% of the intact density of the host Salado salt. Creep closure of the shaft will further compact the crushed salt over time, thereby reducing the crushed-salt permeability from the initial state and creating an effective long-term seal. A structural model and a fluid flow model have been developed to provide an estimate of crushed-salt reconsolidation rate as a function of depth, time, and pore pressure. Model results are obtained in terms of crushed-salt permeability as a function of time and depth within the salt column. Model results indicate that average salt column permeability will be reduced to 3.3 x 10 -20 m 2 in about 100 years, which provides for an acceptable long-term seal component

  16. Research of environmentally-friendly utilization methods of the crushed stone waste on granite quarries

    Directory of Open Access Journals (Sweden)

    Levytskyi V.G.

    2017-12-01

    Full Text Available The analysis of activity of stone-mining enterprises shows the low competitiveness of crushed stone products Upgrading the quality of crushed stone and production of the European standard fractions requires to use of new technologies and equipment. The main waste of crushed stone pits is сrushed granite waste, which high percent of an exit is caused by outdated equipment and incorrectly selected technological parameters of the crushing process. Crushed-granite waste is stored in dumps which occupy large areas and negatively effect on production area ecology. In November 2017, the Government of Ukraine accepted the National Waste Management Strategy until 2030, the main aim of it is develop a strategy of the mineral raw materials balanced use and international standards introduction at the national level. Therefore, the problem of complex utilization and recycling of waste from stone-mining enterprises with receiving a qualitative secondary product is relevant. The publication presents the сrushed granite waste volumes by crushed stone pit, its properties and main directions of utilization. The ecological influence of waste dumps, in particular granite dust, on the environment and human, the strategy of using non-waste technologies and ecological features of сrushed granite waste secondary processing are considered

  17. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  18. Study on characteristics of printed circuit board liberation and its crushed products.

    Science.gov (United States)

    Quan, Cui; Li, Aimin; Gao, Ningbo

    2012-11-01

    Recycling printed circuit board waste (PCBW) waste is a hot issue of environmental protection and resource recycling. Mechanical and thermo-chemical methods are two traditional recycling processes for PCBW. In the present research, a two-step crushing process combined with a coarse-crushing step and a fine-pulverizing step was adopted, and then the crushed products were classified into seven different fractions with a standard sieve. The liberation situation and particle shape in different size fractions were observed. Properties of different size fractions, such as heating value, thermogravimetric, proximate, ultimate and chemical analysis were determined. The Rosin-Rammler model was applied to analyze the particle size distribution of crushed material. The results indicated that complete liberation of metals from the PCBW was achieved at a size less than 0.59 mm, but the nonmetal particle in the smaller-than-0.15 mm fraction is liable to aggregate. Copper was the most prominent metal in PCBW and mainly enriched in the 0.42-0.25 mm particle size. The Rosin-Rammler equation adequately fit particle size distribution data of crushed PCBW with a correlation coefficient of 0.9810. The results of heating value and proximate analysis revealed that the PCBW had a low heating value and high ash content. The combustion and pyrolysis process of PCBW was different and there was an obvious oxidation peak of Cu in combustion runs.

  19. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  20. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  1. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies

    Directory of Open Access Journals (Sweden)

    Mairinger FD

    2014-08-01

    Full Text Available Fabian D Mairinger,1 Robert FH Walter,2 Claudia Vollbrecht,3 Thomas Hager,1 Karl Worm,1 Saskia Ting,1 Jeremias Wohlschläger,1 Paul Zarogoulidis,4 Konstantinos Zarogoulidis,4 Kurt W Schmid1 1Institute of Pathology, 2Ruhrlandklinik, West German Lung Center, University Hospital Essen, Essen, 3Institute of Pathology, University Hospital Cologne, Cologne, Germany; 4Pulmonary Department, Oncology Unit, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece Background and methods: Isothermal multiple displacement amplification (IMDA can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. Results: A total of 250 µg DNA (concentration 5 µg/µL was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. Conclusion: We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA. Keywords: isothermal multiple displacement amplification, isothermal, whole

  2. Comparison of diagnostic quality of kidney biopsy obtained using 16g and 18g needles in patients with diffuse renal disease

    Directory of Open Access Journals (Sweden)

    Komal Arora

    2012-01-01

    Full Text Available To determine the diagnostic quality and complication rates of 16G and 18G needles in biopsy of the kidney, we performed renal biopsy using a biopsy gun under ultrasound guidance in 50 patients who were prospectively and evenly assigned to one of the two needle biopsy methods from April 2007 until May 2008. Two cores of renal biopsy specimen were obtained in each case and subjected to histopathological and immunoflourescence (IF examination. Pain associated with the procedure was assessed using a visual analog scale. The number of glomeruli retrieved using the 16G needle ranged from 0 to 30 (mean 9.42 ± 5.5 and those retrieved using 18G needle ranged from 0 to 19 (mean 7.72 ± 4.4, P <0.05. The quality of biopsy was poorer with 18G needle as compared with 16G needles because of a higher amount of fragmentation and crushing artifact. There was no difference in the compli-cation rates between the two needles (2% each. The 16G needle was associated with significantly more pain than the 18G needle. We conclude that our study demonstrates the benefit of the larger 16G needle in providing more tissue and glomeruli, which is more diagnostically useful. However, the use of 16G needle was associated with significantly more pain than the 18G needle, and may be a better compromise for diagnostic usefulness and patient acceptability.

  3. Cask crush pad analysis using detailed and simplified analysis methods

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1997-01-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Fluorinel and Storage Facility (FAST). This facility, located at the Idaho Chemical Processing Plant (ICPP) at the Idaho national Engineering and Environmental Laboratory (INEEL), is a US Department of Energy site. The basis for this study is an analysis by Uldrich and Hawkes. The purpose of this analysis was to evaluate various hypothetical cask drop orientations to ensure that the crush pad design was adequate and the cask deceleration at impact was less than 100 g. It is demonstrated herein that a large spent fuel shipping cask, when dropped onto a foam crush pad, can be analyzed by either hand methods or by sophisticated dynamic finite element analysis using computer codes such as ABAQUS. Results from the two methods are compared to evaluate accuracy of the simplified hand analysis approach

  4. Axial Crush of the Tubular Structure with Various Cee-Shaped Cross-Sections

    International Nuclear Information System (INIS)

    Afshar, Reza; Ali, Aidy; Sahari, B B; Bayat, M

    2011-01-01

    Tubular structure with various Cee-shaped cross sections is numerically investigated in order to find the centre of gravity (COG) under axial crush by using program code of ANSYS/LS-DYNA. A subroutine is developed using this code to obtain the COG of deformed shape, during and after crush deformation. The effect of wall thickness of the structure on displacement of COG is also studied. Subsequently, the effect of opening angle of Cee become more prominent as the wall thickness of the structure decreases and as the thickness increases, displacement of the COG in crush direction almost stabilizes for all opening angle of Cee in the range of (10 0 - 90 0 ). Furthermore, Variation of I yy of structure with thicker wall for different cases of applied weight is approximately identical. The value of mass moment of inertia with respect to X and Z axes through the model COG (I zx ) in comparison with I yy can be neglected in the case of axial crush along Y direction.

  5. Evaluation of potential crushed-salt constitutive models

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Sambeek, L.L. Van; Chen, R.; Pfeifle, T.W.; Nieland, J.D.; Hansen, F.D.

    1995-12-01

    Constitutive models describing the deformation of crushed salt are presented in this report. Ten constitutive models with potential to describe the phenomenological and micromechanical processes for crushed salt were selected from a literature search. Three of these ten constitutive models, termed Sjaardema-Krieg, Zeuch, and Spiers models, were adopted as candidate constitutive models. The candidate constitutive models were generalized in a consistent manner to three-dimensional states of stress and modified to include the effects of temperature, grain size, and moisture content. A database including hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt was used to determine material parameters for the candidate constitutive models. Nonlinear least-squares model fitting to data from the hydrostatic consolidation tests, the shear consolidation tests, and a combination of the shear and hydrostatic tests produces three sets of material parameter values for the candidate models. The change in material parameter values from test group to test group indicates the empirical nature of the models. To evaluate the predictive capability of the candidate models, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the models to predict the test data, the Spiers model appeared to perform slightly better than the other two candidate models. The work reported here is a first-of-its kind evaluation of constitutive models for reconsolidation of crushed salt. Questions remain to be answered. Deficiencies in models and databases are identified and recommendations for future work are made. 85 refs

  6. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  7. Analysis of the engine fragment threat and the crush environment for small packages carried on U.S. commercial jet aircraft

    International Nuclear Information System (INIS)

    Hartman, W.F.; McClure, J.D.; von Riesemann, W.A.

    1978-01-01

    The results of two separate analyses are reported. The engine fragment analysis determined the probability of a small package being in the path of a fragment from a failure in a gas turbine engine. The calculated values show that, depending on aircraft type, the incidence rate varies by approximately an order of magnitude from a high of about once per 5 million flights to a low of nearly once every 40 million package flights for a flight of five hours' duration. The analysis of the crush environment consisted of an examination of two principal crush modes, i.e., vertical and longitudinal crush. The vertical crush mode was examined by formulating a structural model of the cargo deck beams of the aircraft. The longitudinal crush mode was studied by using dynamic models of the aircraft cargo and the radioactive material package (RAM). The results of the analysis of these crush modes provided the basis for the formulation of a 310 kN/(70,000 lb) crush test to simulate vertical crush. The longitudinal crush analysis indicated that it was possible, under infrequently occurring conditions, to produce extremely large crush forces and hence it was recommended that RAM packages be located in the aft end of aircraft cargo compartments to minimize the effects of longitudinal crush

  8. Analysis of a hypothetical dropped spent nuclear fuel shipping cask impacting a floor mounted crush pad

    International Nuclear Information System (INIS)

    Hawkes, B.D.; Uldrich, E.D.

    1998-03-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Idaho Chemical Processing Plant. The 110-ton Large Cell Cask was assumed to be accidentally dropped onto the parapet of the unloading pool, causing the cask to tumble through the pool water and impact the floor mounted crush pad with the cask's top corner. The crush pad contains rigid polyurethane foam, which was modeled in a separate computer analysis to simulate the manufacturer's testing of the foam and to determine the foam's stress and strain characteristics. This computer analysis verified that the foam was accurately represented in the analysis to follow. A detailed non-linear, dynamic finite element analysis was then performed on the crush pad and adjacent pool structure to assure that a drop of this massive cask does not result in unacceptable damage to the storage facility. Additionally, verification was made that the crush pad adequately protects the cask from severe impact loading. At impact, the cask has significant vertical, horizontal and rotational velocities. The crush pad absorbs much of the energy of the cask through plastic deformation during primary and secondary impacts. After the primary impact with the crush pad, the cask still has sufficient energy to rebound and rotate until it impacts the pool wall. An assessment is made of the damage to the crush pad and pool wall and of the impact loading on the cask

  9. A benchmark study of procedures for analysis of axial crushing of bulbous bows

    DEFF Research Database (Denmark)

    Yamada, Yasuhira; Pedersen, Preben Terndrup

    2008-01-01

    Simplified methods to estimate mean axial crushing forces of plated structures are reviewed and applied to a series of experimental results for axial crushing of large-scale bulbous bow models. Methods based on intersection unit elements such as L-, T- and X-type elements as well as methods based...

  10. Adaptation of oral medication in people institutionalized in nursing homes for whom medication is crushed: The ADECUA Study

    Directory of Open Access Journals (Sweden)

    Francisco Apolo Carvajal

    2016-12-01

    Full Text Available Purpose: To evaluate the effect of pharmacist interventions in the adaptation of pharmaceutical forms in elders institutionalized in nursing homes whose medicines are crushed, which may have a clinical relevance. Methods: Quasi-experimental, multicenter, transversal and prospective study carried out in 10 nursing homes. Subjects for whom drugs were being crushed were identified. Their treatments were reviewed in order to identify drugs that should not be crushed. In these cases, we proposed an alternative to the physician and we evaluated the degree of acceptance, its association to other variables and the pre-post adaptation index (tablets that can be crushed and capsules that can be opened/ total number of tablets and capsules before and after the intervention. Moreover, health professionals received a training course. Results: Medication was being crushed for 33% (618/1875 of residents (mean: 5 drugs susceptible of crushing. 220 pharmaceutical interventions were performed, mostly in extended release or gastro-resistant drugs (48% were accepted. Switch was the type of intervention more frequent (79%, mainly to Purpose: To evaluate the effect of pharmacist interventions in the adaptation of pharmaceutical forms in elders institutionalized in nursing homes whose medicines are crushed, which may have a clinical relevance. Methods: Quasi-experimental, multicenter, transversal and prospective study carried out in 10 nursing homes. Subjects for whom drugs were being crushed were identified. Their treatments were reviewed in order to identify drugs that should not be crushed. In these cases, we proposed an alternative to the physician and we evaluated the degree of acceptance, its association to other variables and the pre-post adaptation index (tablets that can be crushed and capsules that can be opened/ total number of tablets and capsules before and after the intervention. Moreover, health professionals received a training course. Results

  11. Effect of crushing temperature on virgin olive oil quality and composition

    OpenAIRE

    Ö. Kula; A. Yıldırım; A. Yorulmaz; M. Duran; İ. Mutlu; M. Kıvrak

    2018-01-01

    The objective of the current study was to assess the influence of a modified crushing process and kneading operation on the quality parameters, volatile compounds, and the fatty acid and sterol profiles of virgin olive oil from the Edremit yaglik variety. In the study, olive oil samples were produced in two different processes. The first one was produced without malaxation and the second one was produced with the malaxing process. During crushing, the effect of different temperatures was test...

  12. Magnetic resonance imaging evaluation of acute crush injury of rabbit sciatic nerve: correlation with histology

    International Nuclear Information System (INIS)

    Li, X.; Shen, J.; Chen, J.; Wang, X.; Liu, Q.; Liang, B.

    2008-01-01

    To investigate the relation between the quantitative assessment of magnetic resonance imaging (MRI) features and the correlation with histology and functional recovery by using the rabbit sciatic nerve crush model. In New Zealand, 32 rabbits were randomly divided into 2 groups (group A and B); all rabbits underwent crushing injury of their left sciatic nerve. In group A (n = 16), the sciatic nerves were crushed by using microvessel clamps with a strength of 3.61 kg. In group B (n = 16), the sciatic nerves were crushed with a strength of 10.50 kg. Right sciatic nerves were served as controls. Serial MRI of both hind limbs in each rabbit was performed before and at the time point of 1, 2, 4, and 8 weeks after crushed injury. The MRI protocol included T1-weighted spin-echo (T1WI), 3 dimension turbo spin-echo T2-weighted (3DT2WI), T2-weighted turbo spin-echo images with spectral presaturation with inversion recovery (T2WI/SPIR), balanced fast-field echo (B-FFE) and short-time inversion recovery (STIR) sequences. The coronal image of the sciatic nerve was obtained. The nerve and muscle signal ratio (SIR) on each sequence was measured. The function recovery was observed and pathological examination was performed at each time point. A signal intensity increase of the distal segment of crushed sciatic nerves was found on 3DT2WI, T2WI/SP1R, B-FFE, and STIR, but not on T,WI images. Of 32 crushed nerves, 30 nerves showed high signal intensity. The correct diagnostic rate was 93.75% with false negative-positive of 6.25%. The SIR of the crushed sciatic nerve at distal portion was higher than those of the control nerves; there was a statistically significant difference (P 0.05). The SIR between group A and group B was not found statistically significantly different (P > 0.05). The SIR of crushed nerves at distal portion increased at one week after the crush injury, subsequently further increased, and reached a maximum at 2 weeks. The pathological examination revealed myelin

  13. Celecoxib accelerates functional recovery after sciatic nerve crush in the rat

    Directory of Open Access Journals (Sweden)

    Fernández-Garza Nancy E

    2008-11-01

    Full Text Available Abstract The inflammatory response appears to be essential in the modulation of the degeneration and regeneration process after peripheral nerve injury. In injured nerves, cyclooxygenase-2 (COX-2 is strongly upregulated around the injury site, possibly playing a role in the regulation of the inflammatory response. In this study we investigated the effect of celecoxib, a COX-2 inhibitor, on functional recovery after sciatic nerve crush in rats. Unilateral sciatic nerve crush injury was performed on 10 male Wistar rats. Animals on the experimental group (n = 5 received celecoxib (10 mg/kg ip immediately before the crush injury and daily for 7 days after the injury. Control group (n = 5 received normal saline at equal regimen. A sham group (n = 5, where sciatic nerve was exposed but not crushed, was also evaluated. Functional recovery was then assessed by calculating the sciatic functional index (SFI on days 0,1,7,14 and 21 in all groups, and registering the day of motor and walking onset. In comparison with control group, celecoxib treatment (experimental group had significant beneficial effects on SFI, with a significantly better score on day 7. Anti-inflammatory drug celecoxib should be considered in the treatment of peripheral nerve injuries, but further studies are needed to explain the mechanism of its neuroprotective effects.

  14. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  15. A Selective Biomarker Panel Increases the Reproducibility and the Accuracy in Endometrial Biopsy Diagnosis

    DEFF Research Database (Denmark)

    Nastic, Denis; Shanwell, Emma; Wallin, Keng-Ling

    2017-01-01

    Grading and histologic typing of endometrial cancer in biopsy material has a direct impact on the decision to perform lymphadenectomy and/or omentectomy in many cancer centers. Endometrial biopsies are among the most common general surgical pathology specimens. Multiple studies have shown...... that biopsy diagnosis suffers from a lack of reproducibility. Although many biomarkers have been proposed, none have been demonstrated to improve the diagnosis in the biopsy setting. In this study, 70 biopsies with endometrial carcinoma were supplemented with a biomarker panel consisting of ER, PR, P53...

  16. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  17. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  18. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  19. Nutritional parameters of steers receiving different levels of sunflower crushed in partial replacement of soybean meal.

    Science.gov (United States)

    Lima, Hellen L; Goes, Rafael H T B de; Cerilo, Sara L N; Oliveira, Euclides R de; Gressler, Maria G M; Brabes, Kelly C S

    2013-01-01

    To evaluate of the sunflower crushed in nutritional parameters in steers, supplemented at pasture, we used four steers in 4×4 Latin square design. The supplements were provided in 6 g/kg of body weight/animal/day, consisting of sunflower crushed, corn, soybean meal and mineral. All the supplements was isonitrogenous and soybean meal was replaced in 0, 20, 40, and 60% for sunflower crushed. The determination of ruminal pH and ammonia was at 0, 2, 4, 6 and 8 h. after feeding and for short-chain fatty acids it was collected at 0 and 6 h. post-feeding. The dry matter intake was not affected (P>0.05) by inclusion of sunflower crushed (mean=6.59 kg/day). There was no significant effect (P>0.05) for pH for the inclusion of sunflower crushed (mean=6.41). For contents of ruminal NH₃-N was a significant effect (P replacement of soybean meal did not alter nutrition parameters.

  20. Sandvik sharpens in-pit crushing focus

    Energy Technology Data Exchange (ETDEWEB)

    Casteel, K.

    2009-04-15

    Major mining equipment supplier Sandvik Mining and Construction has announced a full-fledged fully mobile crushing plant, the PF300. This is shaping up to be the decade's major addition to the large scale open-cut mining toolkit. The PF300 can be connected to a face conveyor by a loading bridge as well as by belt wagon or transfer conveyor. The article describes design features. 2 figs.

  1. Simulation and modeling of the crushing behavior of structural members

    International Nuclear Information System (INIS)

    Toi, Yutaka

    1986-01-01

    The analysis of the crushing behavior (the behavior of compressive breakdown accompanied by super large deformation) of structural members is an important subject which becomes the base of the ultimate strength design of the structures which may cause collision accident such as automobiles, ships and aircrafts, and of those which are feared to be collided such as offshore structures, bridge piers and nuclear power plants. However, since it is a phenomenon of very strong nonlinearity, its analysis is accompanied by large difficulty. In this report, three kinds of the approach for this problem, that is, rigid-plastic theoretical analysis, the simulation using a rigid body and spring model and nonlinear finite element analysis, are explained, referring to the example of calculation by the authors on the non-axisymmetric crushing problem of cylindrical shells. In crushing problem, the matters of concern are the amount of collision energy which can be absorbed by the plastic deformation of structures and the amount of deformation. It can be said that the increase of calculation cost brings about the heightening of calculation accuracy. The nonlinear finite element analysis is promising because its calculation cost is expected to lower in future. (Kako, I.)

  2. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  3. Effects of crushed conspecifics on growth and survival of Penaeus monodon Fabricius post larvae

    NARCIS (Netherlands)

    Nga, B.T.; Lürling, M.F.L.L.W.; Peeters, E.T.H.M.; Roijackers, R.M.M.; Scheffer, M.; Nghia, T.T.

    2006-01-01

    In the present study, the hypothesis tested was that Penaeus monodon post-larvae (PL) experience lower growth when exposed to crushed conspecifics, which was achieved by exposing individual P. monodon PL with abundant food for 4 weeks to a gradient from 0 to 100 crushed conspecific PL L1. Both dry

  4. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  5. Application of Crushed Concrete in Geotechnical Engineering - Selected Issues

    Science.gov (United States)

    Kawalec, Jacek; Kwiecien, Slawomir; Pilipenko, Anton; Rybak, Jarosław

    2017-12-01

    The reuse of building materials becomes an important issue in sustainable engineering. As the technical requirements for civil engineering structures changes with time and the life time is limited, the need of building new objects meets the necessity of recycling of the existing ones. In the case of steel structures, the possibility of recycling is obvious, also in the case of wooden constructions, the possibility of “burning” solves the problem. The concrete waste is generated mainly as a result of the demolition and reconstruction of residential and industrial buildings. These types of waste are basically made from crushed rocks and cement minerals and contain non-hydrated cement particles in its composition. Concrete poses a lot of problems mainly for two reasons. It is difficult to crush, heavy and hard to transport and demanding in reuse. Different fractions (particle sizes) may be used for different purposes. Starting from very fine particles which can be used in concrete production, through regular 16-300 mm fractions used to form new fills and fill the mats, up to very irregular mixtures used to form stone columns by means of Impulse Compaction or in Dynamic Replacement. The presented study juxtaposes authors experience with crushed concrete used in civil engineering, mainly in geotechnical projects. Authors’ experiences comprise the application of crushed concrete in the new concrete production in Russia, changing pulverized bridge into the fill of mesh sacks, or mattresses used as an effective way to protect the shoreline and the New Orleans East land bridge after Katrina storm (forming a new shoreline better able to withstand wave actions), and finally the use of very irregular concrete fractions to form stone columns in week soils on the example of railway and road projects in Poland. Selected case studies are presented and summarized with regard to social, technical and economic issues including energy consumption needed for proposed technologies

  6. Early myelin breakdown following sural nerve crush: a freeze-fracture study

    Directory of Open Access Journals (Sweden)

    Martinez A.M.B.

    2000-01-01

    Full Text Available In this study we describe the early changes of the myelin sheath following surgical nerve crush. We used the freeze-fracture technique to better evaluate myelin alterations during an early stage of Wallerian degeneration. Rat sural nerves were experimentally crushed and animals were sacrificed by transcardiac perfusion 30 h after surgery. Segments of the nerves were processed for routine transmission electron microscopy and freeze-fracture techniques. Our results show that 30 h after the lesion there was asynchrony in the pattern of Wallerian degeneration, with different nerve fibers exhibiting variable degrees of axon disruption. This was observed by both techniques. Careful examination of several replicas revealed early changes in myelin membranes represented by vacuolization and splitting of consecutive lamellae, rearrangement of intramembranous particles and disappearance of paranodal transverse bands associated or not with retraction of paranodal myelin terminal loops from the axolemma. These alterations are compatible with a direct injury to the myelin sheath following nerve crush. The results are discussed in terms of a similar mechanism underlying both axon and myelin breakdown.

  7. Crushed tablets: does the administration of food vehicles and thickened fluids to aid medication swallowing alter drug release?

    Science.gov (United States)

    Manrique, Yady J; Lee, Danielle J; Islam, Faiza; Nissen, Lisa M; Cichero, Julie A Y; Stokes, Jason R; Steadman, Kathryn J

    2014-01-01

    To evaluate the influence of co-administered vehicles on in vitro dissolution in simulated gastric fluid of crushed immediate release tablets as an indicator for potential drug bioavailability compromise. Release and dissolution of crushed amlodipine, atenolol, carbamazepine and warfarin tablets were tested with six foods and drinks that are frequently used in the clinical setting as mixers for crushed medications (water, orange juice, honey, yoghurt, strawberry jam and water thickened with Easythick powder) in comparison to whole tablets. Five commercial thickening agents (Easythick Advanced, Janbak F, Karicare, Nutilis, Viscaid) at three thickness levels were tested for their effect on the dissolution of crushed atenolol tablets. Atenolol dissolution was unaffected by mixing crushed tablets with thin fluids or food mixers in comparison to whole tablets or crushed tablets in water, but amlodipine was delayed by mixing with jam. Mixing crushed warfarin and carbamazepine tablets with honey, jam or yoghurt caused them to resemble the slow dissolution of whole tablets rather than the faster dissolution of crushed tablets in water or orange juice. Crushing and mixing any of the four medications with thickened water caused a significant delay in dissolution. When tested with atenolol, all types of thickening agents at the greatest thickness significantly restricted dissolution, and products that are primarily based on xanthan gum also delayed dissolution at the intermediate thickness level. Dissolution testing, while simplistic, is a widely used and accepted method for comparing drug release from different formulations as an indicator for in vivo bioavailability. Thickened fluids have the potential to retard drug dissolution when used at the thickest levels. These findings highlight potential clinical implications of the addition of these agents to medications for the purpose of dose delivery and indicate that further investigation of thickened fluids and their

  8. Bench-scale experimental determination of the thermal diffusivity of crushed tuff

    International Nuclear Information System (INIS)

    Ryder, E.E.; Finley, R.E.; George, J.T.; Ho, C.K.; Longenbaugh, R.S.; Connolly, J.R.

    1996-06-01

    A bench-scale experiment was designed and constructed to determine the effective thermal diffusivity of crushed tuff. Crushed tuff particles ranging from 12.5 mm to 37.5 mm (0.5 in. to 1.5 in.) were used to fill a cylindrical volume of 1.58 m 3 at an effective porosity of 0.48. Two iterations of the experiment were completed; the first spanning approximately 502 hours and the second 237 hours. Temperatures near the axial heater reached 700 degrees C, with a significant volume of the test bed exceeding 100 degrees C. Three post-test analysis techniques were used to estimate the thermal diffusivity of the crushed tuff. The first approach used nonlinear parameter estimation linked to a one dimensional radial conduction model to estimate thermal diffusivity from the first 6 hours of test data. The second method used the multiphase TOUGH2 code in conjunction with the first 20 hours of test data not only to estimate the crushed tuffs thermal diffusivity, but also to explore convective behavior within the test bed. Finally, the nonlinear conduction code COYOTE-II was used to determine thermal properties based on 111 hours of cool-down data. The post-test thermal diffusivity estimates of 5.0 x 10-7 m 2 /s to 6.6 x 10-7 m 2 /s were converted to effective thermal conductivities and compared to estimates obtained from published porosity-based relationships. No obvious match between the experimental data and published relationships was found to exist; however, additional data for other particle sizes and porosities are needed

  9. Crushed rock sand – An economical and ecological alternative to natural sand to optimize concrete mix

    Directory of Open Access Journals (Sweden)

    Sanjay Mundra

    2016-09-01

    Full Text Available The study investigates the use of crushed rock sand as viable alternative to Natural River sand that is being conventionally used as fine aggregate in cement concrete. Various mix designs were developed for different grades of concrete based on IS, ACI and British codes using Natural River sand and crushed rock sand. In each case, the cube compressive strength test, and beam flexure tests were conducted. The results of the study show that, the strength properties of concrete using crushed rock sand are nearly similar to the conventional concrete. The study has shown that crushed stone sand can be used as economic and readily available alternative to river sand and can therefore help to arrest the detrimental effects on the environment caused due to excessive mining of river sand.

  10. Morphologic Features Suggestive of Endometriosis in Nondiagnostic Peritoneal Biopsies.

    Science.gov (United States)

    Harrison, Beth T; Mittal, Khush

    2015-11-01

    Endometriosis is a common disorder that causes significant morbidity from dysmenorrhea, pelvic pain, and subfertility. Establishment of a definitive diagnosis has important therapeutic implications; however, only approximately 50% of biopsies of laparoscopically suspicious areas provide a diagnosis of endometriosis. Histologic criteria for diagnosis require the presence of endometrial glands or endometrial-type stroma. We hypothesize that other frequently present, but nondiagnostic, histologic features of endometriosis suggest its presence in patients with nondiagnostic peritoneal biopsies. We performed a retrospective clinicopathologic study of morphologic and immunohistochemical features that may improve the histologic diagnosis of endometriosis on laparoscopic peritoneal biopsies. We compared diagnostic (n=88) and nondiagnostic (n=54) peritoneal biopsies from pathologically confirmed endometriosis cases with negative peritoneal biopsies (n=84) from early-stage gynecologic cancer cases. Statistical analysis utilized the Fisher exact test. Multiple morphologic features were significantly increased in nondiagnostic biopsies from patients with endometriosis in comparison with those from negative controls, including foamy macrophages (P=0.0001) and submesothelial stromal clusters (SSCs) (P=0.0008). SSCs ranged from subtle aggregates of spindle cells to nodules of whorled spindle cells with small vessels and extravasated red blood cells resembling stromal endometriosis. Immunohistochemical studies confirmed that ER and CD10-positive SSCs were present in a greater proportion of both nondiagnostic and diagnostic peritoneal biopsies and at a greater number of lesions per biopsy. The overall histologic detection rate of peritoneal biopsies for endometriosis was 62.0%, and inclusion of SSCs with or without foamy macrophages in the diagnostic criteria appreciably increased this rate to between 72.5% and 76.8%. We describe SSCs, which appear to be an early or less developed

  11. Evaluation of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia).

    Science.gov (United States)

    Sladakovic, Izidora; Ellis, Angela E; Divers, Stephen J

    2017-01-01

    OBJECTIVE To evaluate the efficacy and safety of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia). ANIMALS 15 adult pigeons. PROCEDURES Each pigeon was anesthetized, and the upper gastrointestinal tract (from the cervical portion of the esophagus to the ventriculus) was endoscopically evaluated by use of a rigid endoscope inserted orally. Saline (0.9% NaCl) solution was orally infused to achieve lumen dilation and visibility. Two mucosal biopsy specimens were collected from each of the proventriculus and ventriculus, histologically evaluated, and graded for crush artifacts and depth. Pigeons were monitored for adverse effects for 3 to 6 days after the procedure, after which they were euthanized for necropsy. RESULTS Gastroscopy via the oral approach provided excellent visibility of the lumen and mucosal surfaces of the proventriculus and cranial portion of the ventriculus and was safe provided that appropriate precautions were taken. Two intraoperative deaths occurred at the beginning of the study; following procedure refinement, no additional deaths occurred. No major adverse effects of the procedure were detected in the remaining 13 pigeons during the postoperative monitoring period or at necropsy. Diagnostic quality of proventriculus specimens was adequate for 10 of 13 pigeons. Eight of 13 ventriculus specimens were of inadequate quality, and only 3 were of adequate quality. CONCLUSIONS AND CLINICAL RELEVANCE Gastroscopy was useful for evaluating the lumen and mucosal surface of the proventriculus and ventriculus in pigeons, and biopsy of those organs was safely performed with the appropriate technique. Further evaluation of these techniques is needed in birds with clinical disease and birds of other species.

  12. Distribution of crushing strength of tablets

    DEFF Research Database (Denmark)

    Sonnergaard, Jørn

    2002-01-01

    The distribution of a given set of data is important since most parametric statistical tests are based on the assumption that the studied data are normal distributed. In analysis of fracture mechanics the Weibull distribution is widely used and the derived Weibull modulus is interpreted as a mate...... data from nine model tablet formulations and four commercial tablets are shown to follow the normal distribution. The importance of proper cleaning of the crushing strength apparatus is demonstrated....

  13. A local isotropic/global orthotropic finite element technique for modeling the crush of wood in impact limiters

    International Nuclear Information System (INIS)

    Attaway, S.W.; Yoshimura, H.R.

    1989-01-01

    Wood is often used as the energy absorbing material in impact limiters, because it begins to crush at low strains, then maintains a near constant crush stress up to nearly 60% volume reduction, and then locks up. Hill (Hill and Joseph, 1974) has performed tests that show that wood is an excellent absorber. However, wood's orthotropic behavior for large crush is difficult to model. In the past, analysts have used isotropic foam-like material models for modeling wood. A new finite element technique is presented in this paper that gives a better model of wood crush than the model currently in use. The orthotropic technique is based on locally isotropic, but globally orthotropic (LIGO) (Attaway, 1988) assumptions in which alternating layers of hard and soft crushable material are used. Each layer is isotropic; however, by alternating hard and soft thin layers, the resulting global behavior is orthotropic. In the remainder of this paper, the new technique for modeling orthotropic wood crush will be presented. The model is used to predict the crush behavior for different grain orientations of balsa wood. As an example problem, an impact limiter containing balsa wood as the crushable material is analyzed using both an isotropic model and the LIGO model

  14. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  15. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  16. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Directory of Open Access Journals (Sweden)

    Inpyeong Hwang

    2016-01-01

    Full Text Available Purpose: The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC, and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. Methods: This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA concentrations, PSA density, and pathological features in the biopsy specimens. Results: PC was detected in 289 patients (39.0%. Among the PC patients, 66 patients (22.8% had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001. Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%. Conclusion: Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  17. The Effects of Phrenic Nerve Degeneration by Axotomy and Crush on the Electrical Activities of Diaphragm Muscles of Rats.

    Science.gov (United States)

    Alkiş, Mehmet Eşref; Kavak, Servet; Sayır, Fuat; Him, Aydin

    2016-03-01

    The aim of this study was to investigate the effect of axotomy and crush-related degeneration on the electrical activities of diaphragm muscle strips of experimental rats. In the present study, twenty-one male Wistar-albino rats were used and divided into three groups. The animals in the first group were not crushed or axotomized and served as controls. Phrenic nerves of the rats in the second and third groups were crushed or axotomized in the diaphragm muscle. Resting membrane potential (RMP) was decreased significantly in both crush and axotomy of diaphragm muscle strips of experimental rats (p phrenic nerves may produce electrical activities in the diaphragm muscle of the rat by depolarization time and half-repolarization time prolonged in crush and axotomy rats.

  18. Novel hybrid cryo‐radial method: an emerging alternative to CT‐guided biopsy in suspected lung cancer. A prospective case series and description of technique

    Science.gov (United States)

    Yap, Elaine

    2017-01-01

    In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R‐EBUS) is emerging as a safer method in comparison to CT‐guided biopsy. Despite the better safety profile, the yield of R‐EBUS remains lower (73%) than CT‐guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R‐EBUS Guide Sheath (GS) to produce larger, non‐crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R‐EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post‐biopsy to minimize the risk of bleeding in all patients. A chest X‐ray was performed 1 h post‐procedure. All the PPLs were visualized with R‐EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R‐EBUS. Using an endobronchial blocker improves the safety of this procedure. PMID:29321931

  19. Nutritional parameters of steers receiving different levels of sunflower crushed in partial replacement of soybean meal

    Directory of Open Access Journals (Sweden)

    HELLEN L. LIMA

    2013-10-01

    Full Text Available ABSTRACT To evaluate of the sunflower crushed in nutritional parameters in steers, supplemented at pasture, we used four steers in 4×4 Latin square design. The supplements were provided in 6 g/kg of body weight/animal/day, consisting of sunflower crushed, corn, soybean meal and mineral. All the supplements was isonitrogenous and soybean meal was replaced in 0, 20, 40, and 60% for sunflower crushed. The determination of ruminal pH and ammonia was at 0, 2, 4, 6 and 8 h. after feeding and for short-chain fatty acids it was collected at 0 and 6 h. post-feeding. The dry matter intake was not affected (P>0.05 by inclusion of sunflower crushed (mean=6.59 kg/day. There was no significant effect (P>0.05 for pH for the inclusion of sunflower crushed (mean=6.41. For contents of ruminal NH3-N was a significant effect (P <0.05 only for collection time, and ammonia peaks occurred between 2 and 4 h after feeding, with values of 22.56 and 21.40 mg/dL. The total concentration of short chain fatty acids and the C2:C3 ratio was reduced in 9.6 and 15.43%. The ruminal degradability of NDF was not affected by the supplements. The supplementation with sunflower crushed to beef steers grazing, in partial replacement of soybean meal did not alter nutrition parameters.

  20. Assessment of crushed salt consolidation and fracture healing processes in a nuclear waste repository in salt

    International Nuclear Information System (INIS)

    1984-11-01

    For a nuclear waste repository in salt, two aspects of salt behavior are expected to contribute to favorable conditions for waste isolation. First, consolidation of crushed salt backfill due to creep closure of the underground openings may result in a backfill barrier with low permeability. Second, fractures created in the salt by excavation may heal under the influence of stress and temperature following sealing. This report reviews the status of knowledge regarding crushed salt consolidation and fracture healing, provides analyses which predict the rates at which the processes will occur under repository conditions, and develops requirements for future study. Analyses of the rate at which crushed salt will consolidate are found to be uncertain because of unexplained wide variation in the creep properties of crushed salt obtained from laboratory testing, and because of uncertainties in predictions of long term closure rates of openings in salt. This uncertainty could be resolved to a large degree by additional laboratory testing of crushed salt. Similarly, additional testing of fracture healing processes is required to confirm that healing will be effective under repository conditions. Extensive references, 27 figures, 5 tables

  1. Bone marrow trephine biopsies: A single centre experience in Eastern India

    Directory of Open Access Journals (Sweden)

    Sima Chauhan

    2017-01-01

    Full Text Available Introduction: Bone marrow aspiration (BMA and trephine biopsy are indispensable diagnostic tools for evaluating hematological and nonhematological disorders in the present era. However, trephine biopsy demands greater technical skills and expertise as compared to BMA alone. In this study, we have analyzed the advantages of carrying out trephine biopsy along with BMA in the same sitting. Materials and Methods: This is a prospective observational study carried out from June 2014 to May 2015. The patients attending hematology and medicine outdoors were screened by detailed clinical examination, laboratory investigations including complete blood counts, peripheral smear, and whenever indicated were subjected to BMA and trephine biopsy in the same sitting. Results: Out of total 570 aspirations and trephine biopsies done, 8% showed inadequate aspirates and diagnosis was based only on biopsy findings. Confirmatory diagnosis of aplastic anemia was done on trephine biopsy in 100% cases. Fifty percent cases of granulomas and 33.3% cases of metastasis were missed in aspiration smears. They were diagnosed on trephine biopsy. All cases of myelofibrosis required trephine biopsy for diagnosis, but aspiration alone was adequate for diagnosis in majority of acute leukemias. Conclusion: Trephine biopsy is mandatory for diagnosis of aplastic anemia, myelofibrosis, and for staging of lymphomas. It specially carries diagnostic value in cases of dry tap and bloody aspirates. Aspiration is simple, has high specificity, and is especially useful for nutritional anemia, immune thrombocytopenia, acute leukemia, and multiple myeloma.

  2. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  3. Treatment of solid waste highly contaminated by alpha emitters low-temperature impact crushing/leaching and incineration

    International Nuclear Information System (INIS)

    Carpentier, S.; Bertolotti, G.

    1986-01-01

    Reprocessing plants, hot laboratories, fuel fabrication plants all produce waste containing residual quantities of plutonium and uranium in oxide form which often reach some tens of grammes per m 3 . Appropriate treatment recovers an appreciable amount of fissile material, which could lead to the waste being declassified and able to be disposed of in near ground-level facilities. After a summary sorting at production level, waste can be sent to a low-temperature impact crushing/leaching unit which considerably reduces volumes to be stored. We call this process cryo-crushing/leaching. For burnable crushed particles, a further volume reduction may be obtained by incineration, an operation which is made easier by the low fissile material residue content. Incineration can, of course also be applied directly to burnable solid waste sorted at source and crushed following more conventional methods [fr

  4. Optimal energy control of a crushing process based on vertical shaft impactor

    International Nuclear Information System (INIS)

    Numbi, B.P.; Xia, X.

    2016-01-01

    Highlights: • Energy optimal control strategy of a VSI crushing process is modeled. • Potential of a daily energy cost saving of about 49.7% is shown. • Potential of a daily energy saving of about 15.3% is shown. • Most of energy cost saving is due to the optimal load shifting under time-of-use tariff. • Energy saving is due to the operation of the process at the boundary of the admissible region. - Abstract: This paper presents an optimal control model to improve the operation energy efficiency of a vertical shaft impact (VSI) crushing process. The optimal control model takes the energy cost as the performance index to be minimized by accounting for the time-of-use tariff and process constraints such as storage capacity of the VSI crusher hopper, capacity of the main storage system, flow rate limits, cascade ratio setting, production requirement and product quality requirement. The control variables in the developed model are the belt conveyor feed rate, the material feed rate into the VSI crusher rotor, the bi-flow or cascade feed rate and the rotor tip speed of the crusher. These four control variables are optimally coordinated in order to improve the operation energy efficiency of the VSI crushing process. Simulation results based on a crushing process in a coal-fired power plant demonstrate a potential of a daily energy cost saving of about 49.7% and energy saving of about 15.3% in a high-demand season weekday.

  5. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  6. Histological Spectrum of Idiopathic Noncirrhotic Portal Hypertension in Liver Biopsies From Dialysis Patients.

    Science.gov (United States)

    Lee, Hwajeong; Ainechi, Sanaz; Singh, Mandeep; Ells, Peter F; Sheehan, Christine E; Lin, Jingmei

    2015-09-01

    Liver biopsy is performed for various indications in dialysis patients. Being a less-common subset, the hepatic pathology in renal dialysis is not well documented. Idiopathic noncirrhotic portal hypertension (INCPH) is a clinical entity associated with unexplained portal hypertension and/or a spectrum of histopathological vascular changes in the liver. After encountering INCPH and vascular changes of INCPH in 2 renal dialysis patients, we sought to further investigate this noteworthy association. A random search for patients on hemodialysis or peritoneal dialysis with liver biopsy was performed. Hematoxylin and eosin, reticulin, trichrome, and CK7 stains were performed on formalin-fixed, paraffin-embedded tissue sections. Histopathological features were reviewed, and the results were correlated with clinical findings. In all, 13 liver biopsies were retrieved. The mean cumulative duration of dialysis was 50 months (range = 17 months to 11 years). All patients had multiple comorbidities. Indications for biopsy were a combination of abnormal liver function tests (6), portal hypertension (4), ascites (3), and possible cirrhosis (3). Two patients with portal hypertension underwent multiple liver biopsies for diagnostic purposes. All (100%) biopsies showed some histological features of INCPH, including narrowed portal venous lumen (9), increased portal vascular channels (8), shunt vessels (3), dilated sinusoids (9), regenerative nodule (5), and features of venous outflow obstruction (3). No cirrhosis was identified. Liver biopsies from patients on dialysis demonstrate histopathological vascular changes of INCPH. Some (31%) patients present with portal hypertension without cirrhosis. The histological changes may be reflective of underlying risk factors for INCPH in this group. © The Author(s) 2015.

  7. environmental impact of aggregate mining by crush rock industries

    African Journals Online (AJOL)

    2012-07-02

    Jul 2, 2012 ... in form of crushed rock and it is also an essential con- stituent of many ... of production; processing or during extraction. Since .... reserves through deep quarrying. 1.3. ...... Audit Report of Port Harcourt Flour Mill Port Har- court.

  8. Current status of crushed rock and whole rock column studies

    International Nuclear Information System (INIS)

    Vine, E.N.; Daniels, W.R.; Rundberg, R.S.; Thompson, J.L.

    1980-01-01

    Measurements on a large number of crushed rock columns of tuff, granite, and argillite are discussed. The isotopes 85 Sr, 137 Cs, 133 Ba, 141 Ce, 152 Eu, /sup 95m/Tc, and 233 U were used. Flow rates were varied from approx. 30 to approx. 30000 m/y. Other parameters studied include isotope concentration and atmosphere. The sorption ratios calculated were compared with batch sorption ratios on the same samples. Methods of studying the movement of radionuclides through whole rock cores are described. The problems associated with sealing the cores to prevent leaking along the exterior surface and one possible solution are discussed. The strontium sorption ratio obtained by elution of one solid tuff core is compared with the batch and crushed rock column sorption ratios

  9. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  10. Assessment of Crushed Water Hyacinth ( Eichhornia crassipes ) as ...

    African Journals Online (AJOL)

    A preliminary study was conducted to evaluate and compare organic buffering capacity of crushed water hyacinth and calcium carbonate on acidic borehole water for aquaculture. Thirty, 25-litre shaded plastic tanks (20-litre filled with experimental water, pH 3.0) of three replicates per treatment of 180 g buffer agent were ...

  11. Cytidine 5’-diphosphocholine administration prevents peripheral neuropathic pain after sciatic nerve crush injury in rats

    Directory of Open Access Journals (Sweden)

    Emril DR

    2016-05-01

    Full Text Available Dessy R Emril,1 Samekto Wibowo,2 Lucas Meliala,2 Rina Susilowati3 1Department of Neurology, Faculty of Medicine, Syiah Kuala University, Banda Aceh, 2Department of Neurology, 3Department of Histology and Cell Biology, Faculty of Medicine, Universitas Gadjah Mada, Yogyakarta, IndonesiaBackground: Cytidine 5’-diphosphocholine (citicoline has been shown to have beneficial effects in central nervous system injury as well as in motoric functional recovery after peripheral nerve injury. This study aimed to examine the effect of citicoline on prevention of neuropathic pain in a rat model of sciatic nerve crush injury.Methods: Forty experimental rats were divided into four groups. In three groups, the right sciatic nerves were crushed in the mid-thigh region, and a gelatin sponge moistened with 0.4 or 0.8 mL of 100 µmol/L citicoline, or saline 0.4 mL in the control group, was applied. The fourth group of rats was sham-operated, ie the sciatic nerve was exposed with no crush. Functional assessments were performed 4 weeks after crush injury. von Frey filaments (100 g threshold were used to assess neuropathic pain. In addition, the sciatic functional index and extensor postural thrust (EPT tests were used to assess motoric function.Results: The crush/citicoline 0.4 mL group had a lower percentage of pain (23.53%, n=17 compared with the crush/saline group (53.33%, n=15, P<0.005. The crush/citicoline 0.4 mL group also showed better motoric recovery, as seen in stronger EPT results (P<0.001. However, the sciatic functional index analysis did not show significant differences between groups (P=0.35. The crush/citicoline 0.8 mL group showed a higher percentage of pain (66.67%, n=18 and less EPT recovery. These results may be explained by more severe nerve injury due to compression with a larger administered volume.Conclusion: In situ administration of 0.4 mL of 100 μmol/L citicoline prevents the occurrence of neuropathic pain and induces motoric recovery

  12. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  13. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  14. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  15. The value of bladder mapping and prostatic urethra biopsies for detection of carcinoma in situ (CIS).

    Science.gov (United States)

    Gudjónsson, Sigurdur; Bläckberg, Mats; Chebil, Gunilla; Jahnson, Staffan; Olsson, Hans; Bendahl, Pär-Ola; Månsson, Wiking; Liedberg, Fredrik

    2012-07-01

    It is well known that CIS is a major risk factor for muscle-invasive bladder cancer and that this entity can be difficult to diagnose. Taking cold-cup mapping biopsies from different areas of the bladder (BMAP) is commonly used in patients at risk of harbouring CIS. The diagnostic accuracy of this approach has not been assessed until now. By using the CIS found in the cystoprostatectomy specimen as an indicator of the true occurrence of CIS and comparing that with the findings of BMAP, it is clear that the sensitivity of BMAP to detect CIS when present is low and that negative findings should be considered unreliable. To assess the value of bladder mapping and prostatic urethra biopsies for detection of urothelial carcinoma in situ (CIS). CIS of the urinary bladder is a flat high-grade lesion of the mucosa associated with a significant risk of progression to muscle-invasive disease. CIS is difficult to identify on cystoscopy, and definite diagnosis requires histopathology. Traditionally, if CIS is suspected, multiple cold-cup biopsies are taken from the bladder mucosa, and resection biopsies are obtained from the prostatic urethra in males. This approach is often called bladder mapping (BMAP). The accuracy of BMAP as a diagnostic tool is not known. Male patients with bladder cancer scheduled for cystectomy underwent cold-cup bladder biopsies (sidewalls, posterior wall, dome, trigone), and resection biopsies were taken from the prostatic urethra. After cystectomy, the surgical specimen was investigated in a standardised manner and subsequently compared with the BMAP biopsies for the presence of CIS. The histopathology reports of 162 patients were analysed. CIS was detected in 46% of the cystoprostatectomy specimens, and multiple (≥2) CIS lesions were found in 30%. BMAP (cold-cup bladder biopsies + resection biopsies from the prostatic urethra) provided sensitivity of 51% for any CIS, and 55% for multiple CIS lesions. The cold-cup biopsies for CIS in the bladder

  16. Micromechanics of pressure-induced grain crushing in porous rocks

    Science.gov (United States)

    Zhang, Jiaxiang; Wong, Teng-Fong; Davis, Daniel M.

    1990-01-01

    The hydrostatic compaction behavior of a suite of porous sandstones was investigated at confining pressures up to 600 MPa and constant pore pressures ranging up to 50 MPa. These five sandstones (Boise, Kayenta, St. Peter, Berea, and Weber) were selected because of their wide range of porosity (5-35%) and grain size (60-460 μm). We tested the law of effective stress for the porosity change as a function of pressure. Except for Weber sandstone (which has the lowest porosity and smallest grain size), the hydrostat of each sandstone shows an inflection point corresponding to a critical effective pressure beyond which an accelerated, irrecoverable compaction occurs. Our microstructural observations show that brittle grain crushing initiates at this critical pressure. We also observed distributed cleavage cracking in calcite and intensive kinking in mica. The critical pressures for grain crushing in our sandstones range from 75 to 380 MPa. In general, a sandstone with higher porosity and larger grain size has a critical pressure which is lower than that of a sandstone with lower porosity and smaller grain size. We formulate a Hertzian fracture model to analyze the micromechanics of grain crushing. Assuming that the solid grains have preexisting microcracks with dimensions which scale with grain size, we derive an expression for the critical pressure which depends on the porosity, grain size, and fracture toughness of the solid matrix. The theoretical prediction is in reasonable agreement with our experimental data as well as other data from soil and rock mechanics studies for which the critical pressures range over 3 orders of magnitude.

  17. Analysis of the crush environment for lightweight air-transportable accident-resistant containers

    International Nuclear Information System (INIS)

    McClure, J.D.; Hartman, W.F.

    1981-12-01

    This report describes the longitudinal dynamic crush environment for a Lightweight Air-Transportable Accident-Resistant Container (LAARC, now called PAT-2) that can be used to transport small quantities of radioactive material. The analysis of the crush environment involves evaluation of the forces imposed upon the LAARC package during the crash of a large, heavily loaded, cargo aircraft. To perform the analysis, a cargo load column was defined which consisted of a longitudinal prism of cargo of cross-sectional area equal to the projected area of the radioactive-material package and length equal to the longitudinal extent of the cargo compartment in a commercial cargo jet aircraft. To bound the problem, two analyses of the cargo load column were performed, a static stability analysis and a dynamic analysis. The results of these analyses can be applied to other packaging designs and suggest that the physical limits or magnitude of the longitudinal crush forces, which are controlled in part by the yield strength of the cargo and the package size, are much smaller than previously estimated

  18. Hyperbaric oxygenation therapy for crush injuries reduces the risk of complications: research report.

    Science.gov (United States)

    Yamada, Noriaki; Toyoda, Izumi; Doi, Tomoaki; Kumada, Keisuke; Kato, Hisaaki; Yoshida, Shozo; Shirai, Kunihiro; Kanda, Norihide; Ogura, Shinji

    2014-01-01

    Hyperbaric oxygen (HBO2) therapy has been adopted for crush injuries, but there are few studies supporting its use. We therefore investigated the effects of HBO2 on management of patients with complicated crush injuries. This historic cohort study included patients with crush injuries and open fractures with severities greater than or equal to Gustilo class IIIA. We divided the patients into two groups: Control and HBO2. The control group received conventional treatment, while the HBO2 group received conventional treatment plus HBO2. We compared the groups with respect to the incidence of infection, need for additional surgery, and length of intensive care unit (ICU) and hospital stays. There were 16 patients in the HBO2 group and 13 in the control group. There were no patients with infections in the HBO2 group, whereas in the control group six patients had infections and five needed another drainage procedure. These incidences were significantly lower in the HBO2 group (p = 0.003 and 0.013). However, the durations of ICU and hospital stays were similar across the two groups. HBO2 is effective in the management of crush injuries from the viewpoint of reducing complications and reoperations. These observations should be verified in additional studies with larger sample sizes because the patient number is limited.

  19. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Tumour seeding following percutaneous needle biopsy: The real story

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, E.G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Baxter, G., E-mail: grant.baxter@ggc.scot.nhs.uk [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2011-11-15

    The demand for percutaneous needle biopsy is greater than ever before and with the majority of procedures requiring imaging guidance, radiologists have an increasingly important role in the diagnostic work-up of patients with suspected malignancy. All invasive procedures incur potential risks; therefore, clinicians should be aware of the most frequently encountered complications and have a realistic idea of their likelihood. Tumour seeding, whereby malignant cells are deposited along the tract of a biopsy needle, can have disastrous consequences particularly in patients who are organ transplant candidates or in those who would otherwise expect good long-term survival. Fortunately, tumour seeding is a rare occurrence, yet the issue invariably receives a high profile and is often regarded as a major contraindication to certain biopsy procedures. Although its existence is in no doubt, realistic insight into its likelihood across the spectrum of biopsy procedures and multiple anatomical sites is required to permit accurate patient counselling and risk stratification. This review provides a comprehensive overview of tumour seeding and examines the likelihood of this much feared complication across the range of commonly performed diagnostic biopsy procedures. Conclusions have been derived from an extensive analysis of the published literature, and a number of key recommendations should assist practitioners in their everyday practice.

  1. Nitrate removal from aquaculture effluents using woodchip bioreactors improved by adding sulfur granules and crushed seashells

    DEFF Research Database (Denmark)

    von Ahnen, Mathis; Pedersen, Per Bovbjerg; Dalsgaard, Johanne

    2018-01-01

    This study examined the effects on nitrate removal when adding sulfur granules and crushed seashells to a woodchip bioreactor treating aquaculture effluents. Using a central composite design, the two components were added at three levels (0.000, 0.125 and 0.250 m3/m3 bioreactor volume) to 13......, the inclusion of crushed seashells together with sulfur granules helped to maintain the pH above 7.4 and prevent a production (i.e., release) of nitrite. According to the modeled response surfaces, a sulfur granule:crushed seashell:woodchip mixture ratio containing about 0.2 m3 sulfur granules and 0.1 m3...... crushed seashells per m3 reactor volume would give the best results with respect to high N removal and minimal nitrite release. In conclusion, the study showed that N removal in woodchip bioreactors may be improved by adding sulfur granules and seashells, contributing to the optimization of woodchip...

  2. Treatment of solid waste highly contaminated by alpha emitters: Low-temperature impact crushing, leaching and incineration

    International Nuclear Information System (INIS)

    Bertolotti, G.; Vigreux, B.; Caillol, A.; Koehly, G.

    1987-01-01

    Reprocessing plants, hot laboratories and fuel fabrication plants produce solid wastes containing residual amounts of plutonium and uranium in nitrate and oxide form at concentrations up to several tens of grams per m/sup 3/. Dismantling of nuclear facilities having handled these radioelements also generates large volumes of solid wastes highly contaminated with alpha emitters. It is desirable to process these alpha wastes to recover valuable fissile materials and/or permit surface storage. Solid waste treatment by low-temperature impact crushing and then leaching, after minimal sorting and classifying at the sites of production, meets the corresponding requirements for high volume reduction plus fissile material recovery or waste decontamination. Additional volume reduction of crushed wastes containing mainly combustible materials can be obtained by incineration. This is facilitated by the low fissile material content after low-temperature impact crushing and leaching. Sorted wastes can also be leached or incinerated directly after, in most cases, crushing by more conventional techniques

  3. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  4. Axial Crushing Behaviors of Thin-Walled Corrugated and Circular Tubes - A Comparative Study

    Science.gov (United States)

    Reyaz-Ur-Rahim, Mohd.; Bharti, P. K.; Umer, Afaque

    2017-10-01

    With the help of finite element analysis, this research paper deals with the energy absorption and collapse behavior with different corrugated section geometries of hollow tubes made of aluminum alloy 6060-T4. Literature available experimental data were used to validate the numerical models of the structures investigated. Based on the results available for symmetric crushing of circular tubes, models were developed to investigate corrugated thin-walled structures behavior. To study the collapse mechanism and energy absorbing ability in axial compression, the simulation was carried in ABAQUS /EXPLICIT code. In the simulation part, specimens were prepared and axially crushed to one-fourth length of the tube and the energy diagram of crushing force versus axial displacement is shown. The effect of various parameters such as pitch, mean diameter, corrugation, amplitude, the thickness is demonstrated with the help of diagrams. The overall result shows that the corrugated section geometry could be a good alternative to the conventional tubes.

  5. Crushed aggregates for roads and their properties for frost protection

    Science.gov (United States)

    Kuznetsova, Elena; Willy Danielsen, Svein

    2015-04-01

    Crushed aggregates for roads and their properties for frost protection Elena Kuznetsova, NTNU and Svein Willy Danielsen, SINTEF With natural (fluvial, glaciofluvial) sand/gravel resources being rapidly depleted in many countries, the last decade has seen a significant trend towards using more alternative materials for construction purpose. In Norway the development and implementation of crushed aggregate technology has been the most important way to get around the problem with increased resource scarcity. Today Norway is one the European countries with the highest percentage of crushed/manufactured aggregates. A crushed product will reveal a different particle size distribution, a sharper, more angular particle shape, and not least - a significantly different mineral composition. The latter may often be characterised by more polymineral composition, and it will also much more depend on the local bedrock. When handled with care and knowledge, these differences can give the user a lot of new opportunities relating to materials design. Norwegian road construction practice has changed significantly during the last 40 years due to the replacement of gravel by crushed rock materials in the granular layers of the pavements. The use of non-processed rock materials from blasting was allowed in the subbase layer until 2012. This was a reason for a lot of problems with frost heaving due to inhomogeneity of this material, and in practice it was difficult to control the size of large stones. Since 2012 there is a requirement that rock materials for use in the subbase layer shall be crushed (Handbook N200, 2014). During the spring 2014 The Norwegian Public Roads Administration introduced a new handbook with requirements for roads construction in Norway, including new specifications for the frost protection layer. When pavements are constructed over moist and/or frost susceptible soils in cold and humid environments, the frost protection layer also becomes a very important part

  6. Primary amenorrhea caused by crushing trauma of the pelvis

    NARCIS (Netherlands)

    Donner, G. G.; Pel, M.; Lammes, F. B.

    2000-01-01

    An 18-year-old woman sought treatment for primary amenorrhea. Crushing trauma of the pelvis in her childhood had caused separation between the uterine corpus and the cervix. Through a combined abdominal and vaginal approach the continuity of the uterine outflow tract was restored. Years later, after

  7. Crushing and Fracture of Lightweight Structures

    DEFF Research Database (Denmark)

    Urban, Jesper

    2003-01-01

    and Latham (1968). Good agreement between the analytical models and the experiments is found. The crushing behaviour of two high speed ferries has been analysed with the numerical and analytical methods and the results are compared with the existing regulations for high speed craft (HSC). Several failure......The overall objective of the present study has been to develop rational analytical and numerical calculation models to quantify the consequences of collision accidents. The work has primarily been focused on high speed craft (HSC) built in lightweight materials such as aluminium and sandwich...

  8. Cryptanalysis of an Iterated Halving-based hash function: CRUSH

    DEFF Research Database (Denmark)

    Bagheri, Nasour; Henricksen, Matt; Knudsen, Lars Ramkilde

    2009-01-01

    Iterated Halving has been suggested as a replacement to the Merkle–Damgård (MD) construction in 2004 anticipating the attacks on the MDx family of hash functions. The CRUSH hash function provides a specific instantiation of the block cipher for Iterated Halving. The authors identify structural pr...

  9. The percentage of macrophage numbers in rat model of sciatic nerve crush injury

    Directory of Open Access Journals (Sweden)

    Satrio Wicaksono

    2016-02-01

    Full Text Available ABSTRACT Excessive accumulation of macrophages in sciatic nerve fascicles inhibits regeneration of peripheral nerves. The aim of this study is to determine the percentage of the macrophages inside and outside of the fascicles at the proximal, at the site of injury and at the distal segment of rat model of sciatic nerve crush injury. Thirty male 3 months age Wistar rats of 200-230 g were divided into sham-operation group and crush injury group. Termination was performed on day 3, 7, and 14 after crush injury. Immunohistochemical examination was done using anti CD68 antibody. Counting of immunopositive and immunonegative cells was done on three representative fields for extrafascicular and intrafascicular area of proximal, injury and distal segments. The data was presented as percentage of immunopositive cells. The percentage of the macrophages was significantly increased in crush injury group compared to the sham-operated group in all segments of the peripheral nerves. While the percentage of macrophages outside fascicle in all segments of sciatic nerve and within the fascicle in the proximal segment reached its peak on day 3, the percentage of macrophages within the fascicles at the site of injury and distal segments reached the peak later at day 7. In conclusions, accumulation of macrophages outside the nerve fascicles occurs at the beginning of the injury, and then followed later by the accumulation of macrophages within nerve fascicles

  10. Case report 383: Multiple myeloma

    International Nuclear Information System (INIS)

    Kouwenberg, J.J.; Simons, A.J.

    1986-01-01

    A unique and obviously extremely rare example of multiple myeloma has been presented, affecting the peripheral appendicular skeleton and not the hematopoietic system of the axial skeleton, radiologically and probably pathologically. Only one other similar case has been described. The radiological features were confirmed by the pathological studies: a biopsy specimen obtained from a large osteolytic lesion in a patella showed the typical stigma of multiple myeloma; a biopsy from the iliac creast showed no abnormality. (orig./SHA)

  11. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  12. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  13. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  14. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  15. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  16. The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    Povoski Stephen P

    2007-10-01

    Full Text Available Abstract Background Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions. Case presentation A female patient presented with 16 breast lesions (eight within each breast, documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome® excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions. Conclusion This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.

  17. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  18. Circumferential scouting punch biopsies to delineate surgical margin for dermatofibrosarcoma protuberans

    Directory of Open Access Journals (Sweden)

    Tsung-Mao Huang

    2012-03-01

    Full Text Available Dermatofibrosarcoma protuberans (DFSP is an uncommon soft-tissue tumor involving the dermis and subcutaneous tissue with a high local recurrence rate after standard excision. Mohs micrographic surgery offers a lower recurrence rate. However, the procedure requires multiple stages of excision with intraoperative histopathological mapping, which is time consuming and expensive. We report our experience of using circumferential scouting punch biopsy technique in five patients to determine in advance the resection margins for DFSP prior to wide excision. Multiple 4 mm punches, usually eight in number, were performed 1–2.5 cm around the palpable borders of DFSP to delineate the resection margins in five consecutive patients. Tumors were excised at a later date along the margin defined by these biopsies and the wounds were repaired with skin graft. The operation was completed in 2 hours in all cases excluding one that required frozen sections for deep margin. No recurrence was noted 2–10 years after the operations. The results suggest that circumferential scouting punch biopsies before wide excision may be an alternative method to define the resection margins for DFSP when Mohs surgery is not available.

  19. suitability of burnt and crushed cow bones as partial replacement

    African Journals Online (AJOL)

    HOD

    3 mix ratio measuring 150x150x150mm were tested for the compressive strength at 7, 14, 21 and 28 days respectively. ... the suitability of using waste products to produce lightweight ... suitability of machine crushed animal bones as partial or.

  20. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  1. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  2. BONE MARROW BIOPSY IN EVALUATION OF HAEMATOLOGICAL DISORDERS

    Directory of Open Access Journals (Sweden)

    Sandhya Rani Sahoo

    2017-04-01

    Full Text Available BACKGROUND Bone Marrow Trephine Biopsy (BMTB and aspiration is critical for diagnosis, prognostic evaluation and monitoring therapeutic response. BMTB is of greater value in assessing cellularity, degree of fibrosis, marrow architecture and especially when aspiration is dry tap. At the same time, it provides sample for immunohistochemistry. MATERIALSAND METHODS It is a single centre observational study conducted from July 2014 to July 2016 in Department of Pathology, S.C.B. Medical College, Cuttack, which included both cell block and touch imprint along with trephine biopsy. Cases selected where lymphoma studied for pattern and extent of infiltration. Aspiration with dry tap and selected cases of myeloproliferative disorders, myelodysplastic syndrome, leukaemia (both acute and chronic, anaemia, multiple myeloma were studied. Jamshidi needle was used for biopsy. Samples obtained were formalin preserved, kept in decalcification solution (Hammersmith protocol and H and E slides prepared. Special stain-like reticulin and Masson’s trichrome were used for grading of fibrosis. Immunohistochemistry was done on selected cases of lymphoma. RESULTS Out of total 100 cases studied, 60 were of haematopoietic and lymphoid neoplasms, 12 anaemia, 20 secondary metastasis, 8 miscellaneous (1 haemophagocytic lymphohistiocytic disease, 1 storage disease, 1 granulomatous and 5 ITP. CONCLUSION The study was conducted to establish the advantage of bone marrow biopsy in inadequate and failed aspiration, but both are complementary to each other and together provide a comprehensive evaluation of the bone marrow. Bone marrow fibrosis are well accessed and increased detection of tumour cells in suspected secondary metastasis. Special stains, IHC, cytogenetic study can be done over biopsy block.

  3. Deformations during saturation of the crushed aggregate, Olkiluoto tonalite

    International Nuclear Information System (INIS)

    Laaksonen, R.; Rathmayer, H.; Takala, J.; Toernqvist, J.

    1994-03-01

    Crushed aggregate tonalite produced of crystalline tonalite or a correspondent rock with particle size up to 8 mm (or 16 mm) will be used as backfill material in the VLJ repository caverns at Olkiluoto (in Finland). The backfill material has to retard radionuclides, to restrict the groundwater perlocation and to support mechanically the concrete structure of the repository silos. Mechanical and hydraulic behaviour of crushed tonalite when effected by stresses applied during compaction of the backfill and due to groundwater perlocation was studied at three batches having different gradations. Information about the phenomenon of settlement due to saturation and as a function of the compaction methods was obtained from a literature survey. The maximum amount of possible deformation due to compaction was analyzed with a gyratory device, known to have a good repeatability. In a group of simulation tests using a large oedometer cell the amount of compression due to the saturation process was measured. Also studies on the suitability of different compaction methods could be done with these tests. (43 refs., 49 figs., 3 tabs.)

  4. Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel

    Science.gov (United States)

    Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie

    2011-05-01

    Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.

  5. Geo-Engineering Evaluation of Rock Masses for Crushed Rock and Cut Stones in Khartoum State, Sudan

    Science.gov (United States)

    Kheirelseed, E. E.; Ming, T. H.; Abdalla, S. B.

    The purpose of this study is to find artificial coarse aggregates and cut stones around Khartoum. To meat the objectives of the study, data from both field and laboratory are collected. The field data includes geological investigations based on different methods and samples collection, whereas the laboratory tests consists of specific gravity, water absorption, impact value, crushing value, Los Angeles abrasion, soundness tests. The field and laboratory results were weighed and compiled together to reveal the engineering performance of the different rock masses in term of cut stone and crushed aggregates. The results show that most of the examined rock masses are suitable for crushing, building and dressed stones. For decorative slabs only foliated granite and syenite masses can be used.

  6. Monteris AXiiiS Stereotactic Miniframe for Intracranial Biopsy: Precision, Feasibility, and Ease of Use.

    Science.gov (United States)

    Manjila, Sunil; Knudson, Kathleen E; Johnson, Carleton; Sloan, Andrew E

    2016-06-01

    Stereotactic biopsy is an important and minimally invasive technique used for a variety of indications in neurosurgery. Initially, this technique required a frame, but recently there have been a number of newer, less cumbersome approaches to biopsy including robotic arms, fixed arms, and, more recently, skull-mounted miniframes. Miniframes are attractive because they are disposable and low profile. However, the relatively limited degree of freedom offered by currently available devices necessitates a preplanned burr hole, which in turn limits flexibility and multiple trajectories. The AXiiiS device is a skull-mounted, magnetic resonance imaging-compatible miniframe that provides a similar degree of freedom with a frame while maintaining a low-profile, disposable platform. To assess the image-guided trajectory alignment accuracy using AXiiiS stereotactic miniframe biopsy of intracranial lesions. The accuracy of the AXiiiS device is compared with the Navigus Trajectory Guide as platforms. After approval by our institutional review board, medical records of 10 neurosurgical patients with intracranial pathologies were chosen for AXiiiS stereotactic miniframe biopsy, and histological correlation was obtained. Ten reported cases demonstrate the precision and ease of using the AXiiiS stereotactic miniframe for biopsy of intracranial lesions in conjunction with preoperative magnetic resonance imaging. Multiple trajectories and angles have been used with precision and safety. The AXiiiS stereotactic miniframe is a feasible, safe, and disposable platform for multitrajectory intracranial biopsies. Compared with existing platforms, this novel device provides a more stable base and wider limits of trajectory angles with comparable accuracy and precision.

  7. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  8. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  9. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  10. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  11. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  12. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  13. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  14. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  15. Recovery of salmonella serovar enteritidis from inoculated broiler hatching eggs using shell rinse and shell crush sampling methods

    Science.gov (United States)

    This study compared the recovery of Salmonella from hatching eggs using three sampling methods (eggshell rinsing, eggshell crush following a previous rinse, and eggshell crush without previous rinse). Eggshells were drop-inoculated with approximately 10, 100, or 1,000 cfu/eggshell of S. Enteritidis...

  16. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  17. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  18. Interaction between an Eco-Spiral Bolt and Crushed Rock in a Borehole Evaluated by Pull-Out Testing

    Directory of Open Access Journals (Sweden)

    Seong-Seung Kang

    2017-01-01

    Full Text Available The interactions between an eco-spiral bolt and crushed rocks in a borehole were evaluated by pull-out testing in a laboratory and numerical analysis. The porosity of the crushed rock surrounding the bolt depended on the size of the eco-spiral bolt and affected the eco-spiral bolt’s axial resistance force. The axial resistance force and the porosity of the crushed rocks in the borehole showed an inverse relationship. The porosity was also related to the size of the eco-spiral bolt. The maximum principal stress between the bolt and the rock was related to the porosity of the crushed rock and the size difference between the eco-spiral bolt and the borehole. At low porosity the experimental and numerical analyses show similar relationships between the axial resistance force and the displacement. However, at high porosity, the numerical results deviated greatly from the experimental observation. The initial agreement is attributed to the state of residual resistance after the maximum axial resistance force, and the latter divergence was due to the decreasing axial resistance force owing to slippage.

  19. Transient convergence and compaction of crushed salt as incorporated in the computer code EMOS

    International Nuclear Information System (INIS)

    Heijdra, J.J.; Hamilton, L.F.M.; Prij, J.; Slagter, W.

    1995-11-01

    An improved model for description of the transient convergence of cavities in rock salt, together with an improved model for the compaction of crushed salt is introduced. The covergence model is based on solutions of the analytical expressions based on secondary creep for a cylindrical and spherical cavity in rock salt. For the model for compaction of crushed salt the relations based on theoretical micro mechanisms have been fitted to laboratory results. A description is given of how the improved models are incorporated into the program EMOS. (orig.)

  20. Transient convergence and compaction of crushed salt as incorporated in the computer code EMOS

    Energy Technology Data Exchange (ETDEWEB)

    Heijdra, J.J.; Hamilton, L.F.M.; Prij, J.; Slagter, W.

    1995-11-01

    An improved model for description of the transient convergence of cavities in rock salt, together with an improved model for the compaction of crushed salt is introduced. The covergence model is based on solutions of the analytical expressions based on secondary creep for a cylindrical and spherical cavity in rock salt. For the model for compaction of crushed salt the relations based on theoretical micro mechanisms have been fitted to laboratory results. A description is given of how the improved models are incorporated into the program EMOS. (orig.).

  1. Modeling of the endosperm crush response profile of hard red spring wheat using a single kernel characterization system

    Science.gov (United States)

    When a wheat endosperm is crushed the force profile shows viscoelastic response and the modulus of elasticity is an important parameter that might have substantial influence on wheat milling. An experiment was performed to model endosperm crush response profile (ECRP) and to determine the modulus o...

  2. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  3. Percutaneous transluminal biopsy using 7F forceps for diagnosing malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Young Eun; Kim, Young Hwan; An, Eun Jung; Kim, See Hyung [Keimyung Univ. College of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    To evaluate the usefulness of the percutaneous transluminal biopsy using 7-F forceps for diagnosing malignant biliary obstruction. One hundred and seven consecutive patients with obstructive jaundice underwent transluminal forceps biopsy. The lesions involved the common bile duct (n = 33), common hepatic duct (n = 13), hilum (n = 17), right or left intrahepatic bile duct (n = 32), multiple sites (extra and intrahepatic ducts, n = 7), or anastomotic sites (n = 5). In each patient, an average of three specimens was taken with 7F biopsy forceps through a transhepatic biliary drainage tract. The final diagnosis was confirmed with pathologic findings, or a clinical and radiologic follow up. The final diagnoses showed malignancies in 75 patients and benign biliary obstructions in 32 patients. Pathologic classifications of malignancies established by forceps biopsy included 67 adenocarcinomas, 1 adenosquamous cell carcinoma, and 1 hepatocelluar carcinoma. There were 6 false-negative diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstruction had a sensitivity of 92%, specificity of 100%, positive predictive value of 100%, a negative predictive value of 84.2%, and an accuracy of 94.2%. Percutaneous transluminal forceps biopsy is a safe procedure that is easy to perform through a transhepatic biliary drainage tract. It is a highly accurate technique for diagnosing malignant biliary obstructions.

  4. J. Crush and D.A. McDonald. (eds). 2002. Transnationalism and ...

    African Journals Online (AJOL)

    J. Crush and D.A. McDonald. (eds). 2002. Transnationalism and New African Immigration to South Africa. Cape Town. Southern African Migration Project and the Canadian Association of African Studies. IV + 188 pp. ISBN 0-88911-926-0.

  5. Development of a system for receiving, crushing and screening recycled fuel (REF) material; Kierraetyspolttoaineen vastaanotto-, murskaus- ja seulontajaerjestelmaen kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Nurmi, A [VTT Energy, Jyvaeskylae (Finland)

    1997-12-01

    The goal of this project is to develop a system to which source sorted combustible industrial, office and municipal waste material can be taken and where it is then processed in such way that it can be burnt in modern fluidized bed and circulating bed boilers. The project started in the end of year 1995. The main stages of the project are: (1) Study and analysis of existing technology and equipment, (2) Development of system components, (3) Development of the system, (4) Building a pilot/demonstration plant, (5) Tests and results analysis and (6) Decisions on further actions. In the year 1996 the main stage was development of system components; especially crushing. Results of running slow-speed big crushers were collected, analysed and the main development details determined. Additionally, particle size distribution from different crushing methods were analyzed using also primary and secondary crushing. Development of a heavy-duty 2-rotor ECO-Crusher and a crushing screen was started. Regarding to the development of the REF-system, different alternatives have been analyzed and possible demonstration places have been searched. The first multi-crushing line will be demonstrated in Sweden. (orig.)

  6. Effect of Crushed Sandstone Sand on the Properties of High ...

    African Journals Online (AJOL)

    This paper presents results of the laboratory investigation on high performance concrete (HPC) using crushed sandstone sand as 20%, 40%, and 60% replacement of river sand together with superplastisizer and silica fume (SF). The fresh concrete properties such as slump, air content and fresh concrete density have been ...

  7. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  8. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  9. Inherited and Acquired Muscle Weakness: A Moving Target for Diagnostic Muscle Biopsy.

    Science.gov (United States)

    Stenzel, Werner; Schoser, Benedikt

    2017-08-01

    Inherited and acquired muscular weakness is caused by multiple conditions. While the inherited ones are mostly caused by mutations in genes coding for myopathic or neurogenic diseases, the acquired ones occur due to inflammatory, endocrine, or toxic etiologies. Precise diagnosis of a specific disease may be challenging and may require a multidisciplinary approach. What is the current place for a diagnostic biopsy of skeletal muscle? Diagnostic muscle biopsy lost in this context its first-tier place in the primary diagnostic workup for some diseases, but it is still mandatory for others. We here summarize conditions in which we believe a diagnostic sample is most relevant and mention those in which a biopsy may be secondary or can even be left out. We would like to stress that muscle biopsy nowadays has a new important place in description and definition of new diseases, for example, discovered by modern genetic approaches. Georg Thieme Verlag KG Stuttgart, New York.

  10. Sealing performance assessments of bentonite and bentonite/crushed rock plugs

    International Nuclear Information System (INIS)

    Ouyang, Shoung.

    1990-01-01

    Bentonite and mixtures of bentonite and crushed rock are potential sealing materials for high level nuclear waste repositories. The materials have been used to form cap layers to reduce infiltration for mined waste tailings and can also be used to construct clay liners for municipal as well as industrial waste managements. American Colloid C/S granular dentonite and Apache Leap tuff have been mixed to prepare samples for laboratory flow testing. Bentonite weight percent and crushed tuff gradation are the major variables studied. The sealing performance assessments include high injection pressure flow tests, polyaxial flow tests, high temperature flow tests, and piping tests. The results indicate that an appropriate composition would have at least 25% bentonite by weight mixed with well-graded crushed rock. Hydraulic properties of the mixture plugs may be highly anisotropic if significant particle segregation occurs during sample installation and compaction. Temperature has no negative effects on the sealing performance within the test range from room temperature to 60C. The piping damage to the sealing performance is small if the maximum hydraulic gradient does not exceed 120 and 280 for 25 and 35% bentonite content, respectively. The hydraulic gradients above which flow of bentonite may take place are deemed critical. Analytical work includes the introduction of bentonite occupancy percentage and water content at saturation as two major parameters for the plug design. A permeability model developed is useful for the prediction of permeability in clays. A piping model permits the estimation of critical hydraulic gradient allowed before the flow of bentonite takes place. It can also be used to define the maximum allowable pore diameter of a protective filter layer

  11. Safety and effectiveness of percutaneous biopsy of focal splenic lesions under ultrasonographic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hyun Young; Kim, Joo Heon [Eulji University College of Medicine, Taejeon (Korea, Republic of); Shin, Kyung Sook [Chungnam National University College of Medicine, Taejeon (Korea, Republic of)

    2002-06-15

    To evaluate the diagnostic yield and safety of ultrasound (US)-guided percutaneous needle biopsy for the diagnosis of focal splenic lesions. US guided, automated needle biopsy using an 18-gauge cutting needle was performed in 11 patients, consisted of nine men and two women (mean age=49 years), with focal splenic lesions detected on the CT or US. Six patients (55%) had multiple lesions while five (45%) had a single lesion. Two of eleven patients had splenomegaly. None of 11 patients had the prior diagnosis of extrasplenic or hematopoietic malignancies. The biopsy was considered successful if a specific pathological diagnosis was possible. The diagnostic yield and frequency of complication were retrospectively analyzed. Tissue adequate for histological diagnosis was obtained in nine (82%) of 11 patients, and no complications other than mild, localized discomfort occurred. Multifocal splenic lesions without splenomegaly in five patients were confirmed as Hodgkin's disease (n=2), tuberculosis (n=1), infarction (n=1), and hemangioma (n=1). All single lesion in four patients were proven as benign conditions including hamartoma (n=2), lymphangioma (n=1) and chronic organizing abscess (n=1), and only of them with a large hamartoma received splenectomy while others did not receive further treatment. Although in two (18%) patients with multiple lesions and splenomegaly, no specific diagnosis was established by US-guided biopsy, malignant lymphoma and Hodgkin's disease were confirmed by surgery. US-guided automated needle biopsy is a safe and valuable procedure that can provides a specific diagnosis in patients with splenic lesions.

  12. Gallic acid and exercise training improve motor function, nerve conduction velocity but not pain sense reflex after experimental sciatic nerve crush in male rats

    Directory of Open Access Journals (Sweden)

    Maryam Hajimoradi

    2015-06-01

    Full Text Available Objective: The aim of present study was to evaluate the effects of oral administration of gallic acid (GA for 21 days alone and in combination with exercise on nerve conduction velocity and sensory and motor functions in rats with sciatic nerve crush. Materials and Methods: Seventy adult male Wistar rats (250-300 g were divided randomly into 7 groups with 10 in each: 1 Control (Cont, 2 Crushed + Vehicle (Cr +Veh, 3-5 Crushed + gallic acid (Cr+GA (50, 100, and 200 mg/kg/2 mL, orally, 6 Crushed + exercise (Cr+Exe, and 7 Crushed + exercise + effective dose of gallic acid (Cr+Exe +GA200 for 21 days. In order to establish an animal model of sciatic nerve crush, equivalent to 7 kg of force pressed on 2-3 mm of sciatic nerve for 30 s, three times with 30 s intervals. Pain sense reflex in hot plate, motor coordination in rotarod, and sciatic nerve conduction velocity (SNCV in all groups were tested. Data were analyzed using one-way ANOVA followed by Tukey’s post hoc test and pResults: Pain threshold was increased significantly in untreated crushed rats while motor function and SNCV were decreased in all groups with nerve crush (p

  13. Sustainable normal and high strength recycled aggregate concretes using crushed tested cylinders as coarse aggregates

    Directory of Open Access Journals (Sweden)

    Bilal S. Hamad

    2017-12-01

    Full Text Available The paper reports on a research program that was designed at the American University of Beirut (AUB to investigate the fresh and hardened mechanical properties of a high performance concrete mix produced with partial or full substitution of crushed natural lime-stone aggregates with recycled aggregates from crushed tested cylinders in batching plants. Choosing crushed cylinders as source of recycling would result in reusing portion of the waste products of the concrete production industry. An extensive concrete batching and testing program was conducted to achieve two optimum normal and high strength concrete mixes. The variables were the nominal concrete strength (28 or 60 MPa and the percentage replacement of natural coarse aggregates with recycled aggregates from crushed tested cylinders (0, 20, 40, 60, 80, or 100%. Normal strength tested cylinders were used as source of the recycled aggregates for the normal strength concrete (NSC mix and high strength tested cylinders were used for the high strength concrete (HSC mix. Tests on the trial batches included plastic state slump and hardened state mechanical properties including cylinder compressive strength, cylinder splitting tensile strength, modulus of elasticity, and standard beams flexural strength. The results indicated no significant effect on the slump and around 10% average reduction in the hardened mechanical properties for both investigated levels of concrete compressive strength.

  14. Axial Crushing and Energy Absorption of Empty and Foam Filled Jute-glass/ Epoxy Bi-tubes

    Directory of Open Access Journals (Sweden)

    Khalid Asad A.

    2016-01-01

    Full Text Available Experimental work on the axial crushing of empty and polyurethane foam filled bi-tubular composite cone-tube has been carried out. Hand lay-up method was used to fabricate the bi-tubes using woven roving glass, jute and hybrid jute-glass/epoxy materials. The tubes were of 56 mm diameter, and the cones top diameters were 65 mm. Cone semi-apical angles of 5°, 10°, 15°, 20° and 25° were examined. Height of 120 mm was maintained for all the fabricated specimens. Effects of material used, cone semi apical angle and foam filler on the load-displacement relation, maximum load, crush force efficiency, and the specific energy absorption and failure mode were investigated. Results show that the foam filler improved the progressive crushing process, increased the maximum load and the absorbed energy of the bi-tubes. The maximum crushing load and the specific energy absorption increased with increasing the cone semi apical angle up to 20° for the empty bi-tubes and up to 25° for the foam filled bi-tubes. Progressive failure mode with fiber and matrix cracking was observed at the top narrow side of the fractured bi-tubes as well as at the bottom surface of 20° and 25° cone semi-apical angle bi-tubes.

  15. Hydrostatic and shear consolidation tests with permeability measurements on Waste Isolation Pilot Plant crushed salt

    International Nuclear Information System (INIS)

    Brodsky, N.S.

    1994-03-01

    Crushed natural rock salt is a primary candidate for use as backfill and barrier material at the Waste Isolation Pilot Plant (WIPP) and therefore Sandia National Laboratories (SNL) has been pursuing a laboratory program designed to quantify its consolidation properties and permeability. Variables that influence consolidation rate that have been examined include stress state and moisture content. The experimental results presented in this report complement existing studies and work in progress conducted by SNL. The experiments described in this report were designed to (1) measure permeabilities of consolidated specimens of crushed salt, (2) determine the influence of brine saturation on consolidation under hydrostatic loads, and 3) measure the effects of small applied shear stresses on consolidation properties. The laboratory effort consisted of 18 individual tests: three permeability tests conducted on specimens that had been consolidated at Sandia, six hydrostatic consolidation and permeability tests conducted on specimens of brine-saturated crushed WIPP salt, and nine shear consolidation and permeability tests performed on crushed WIPP salt specimens containing 3 percent brine by weight. For hydrostatic consolidation tests, pressures ranged from 1.72 MPa to 6.90 MPa. For the shear consolidation tests, confining pressures were between 3.45 MPa and 6.90 MPa and applied axial stress differences were between 0.69 and 4.14 MPa. All tests were run under drained conditions at 25 degrees C

  16. Reduction of Biomass Moisture by Crushing/Splitting - A Concept

    Science.gov (United States)

    Paul E. Barnett; Donald L. Sirois; Colin Ashmore

    1986-01-01

    A biomass crusher/splitter concept is presented as a possible n&ant of tsafntainfng rights-of-way (ROW) or harvesting energy wood plantations. The conceptual system would cut, crush, and split small woody biomass leaving it in windrows for drying. A subsequent operation would bale and transport the dried material for use as an energy source. A survey of twenty...

  17. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  18. Implementation of evidence-based guidelines for thyroid nodule biopsy: a model for establishment of practice standards.

    LENUS (Irish Health Repository)

    Hambly, Niamh M

    2011-03-01

    Multiple studies have defined criteria for the selection of thyroid nodules for biopsy. No set of criteria is sufficiently sensitive and specific. The aim of this study is to develop a method for assessing consistency of practice in an ultrasound group and to determine whether a 5-point malignancy rating scale can be used to select patients for biopsy.

  19. Double Kissing Crush Versus Provisional Stenting for Left Main Distal Bifurcation Lesions: DKCRUSH-V Randomized Trial.

    Science.gov (United States)

    Chen, Shao-Liang; Zhang, Jue-Jie; Han, Yaling; Kan, Jing; Chen, Lianglong; Qiu, Chunguang; Jiang, Tiemin; Tao, Ling; Zeng, Hesong; Li, Li; Xia, Yong; Gao, Chuanyu; Santoso, Teguh; Paiboon, Chootopol; Wang, Yan; Kwan, Tak W; Ye, Fei; Tian, Nailiang; Liu, Zhizhong; Lin, Song; Lu, Chengzhi; Wen, Shangyu; Hong, Lang; Zhang, Qi; Sheiban, Imad; Xu, Yawei; Wang, Lefeng; Rab, Tanveer S; Li, Zhanquan; Cheng, Guanchang; Cui, Lianqun; Leon, Martin B; Stone, Gregg W

    2017-11-28

    Provisional stenting (PS) is the most common technique used to treat distal left main (LM) bifurcation lesions in patients with unprotected LM coronary artery disease undergoing percutaneous coronary intervention. The double kissing (DK) crush planned 2-stent technique has been shown to improve clinical outcomes in non-LM bifurcations compared with PS, and in LM bifurcations compared with culotte stenting, but has never been compared with PS in LM bifurcation lesions. The authors sought to determine whether a planned DK crush 2-stent technique is superior to PS for patients with true distal LM bifurcation lesions. The authors randomized 482 patients from 26 centers in 5 countries with true distal LM bifurcation lesions (Medina 1,1,1 or 0,1,1) to PS (n = 242) or DK crush stenting (n = 240). The primary endpoint was the 1-year composite rate of target lesion failure (TLF): cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Routine 13-month angiographic follow-up was scheduled after ascertainment of the primary endpoint. TLF within 1 year occurred in 26 patients (10.7%) assigned to PS, and in 12 patients (5.0%) assigned to DK crush (hazard ratio: 0.42; 95% confidence interval: 0.21 to 0.85; p = 0.02). Compared with PS, DK crush also resulted in lower rates of target vessel myocardial infarction I (2.9% vs. 0.4%; p = 0.03) and definite or probable stent thrombosis (3.3% vs. 0.4%; p = 0.02). Clinically driven target lesion revascularization (7.9% vs. 3.8%; p = 0.06) and angiographic restenosis within the LM complex (14.6% vs. 7.1%; p = 0.10) also tended to be less frequent with DK crush compared with PS. There was no significant difference in cardiac death between the groups. In the present multicenter randomized trial, percutaneous coronary intervention of true distal LM bifurcation lesions using a planned DK crush 2-stent strategy resulted in a lower rate of TLF at 1 year than a PS

  20. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  1. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  2. Ball mill tool for crushing coffee and cocoa beans base on fraction size sieving results

    Science.gov (United States)

    Haryanto, B.; Sirait, M.; Azalea, M.; Alvin; Cahyani, S. E.

    2018-02-01

    Crushing is one of the operation units that aimed to convert the size of solid material to be smoother particle’s size. The operation unit that can be used in this crushing is ball mill. The purpose of this study is to foresee the effect of raw material mass, grinding time, and the number of balls that are used in the ball mill tool related to the amount of raw material of coffee and cocoa beans. Solid material that has become smooth is then sieved with sieve mesh with size number: 50, 70, 100, and 140. It is in order to obtain the mass fraction that escaped from each sieve mesh. From the experiment, it can be concluded that mass percentage fraction of coffee powder is bigger than cocoa powder that escaped from the mesh. Hardness and humidity of coffee beans and cocoa beans have been the important factors that made coffee beans is easier to be crushed than cocoa beans.

  3. The classification of wood chips parameters by crushing of waste cane from different varieties of grapevine

    Directory of Open Access Journals (Sweden)

    Patrik Burg

    2008-01-01

    Full Text Available This work deales with exploitatives parameters monitoring of wood shreder PEZZOLATO 110 Mb by crushing of waste cane of six varieties. The results shows that the wood shreders efficiency, fuel consumption and the wood chips elements size can be influenced by varieties characters of cane. The va­lued machines efficiency was 230–470 kg . h−1 by average volume 40.70 % water in wood. The hig­hest values by cane crushing had the variety Saint Laurent (0.47 t . h−1 and the lowest variety ­Blauer Portugieser (0.23 t . h−1. The specific consumption of petrol Natural 95 was 4.52.10−3–8.12.10−3 l . kg−1. The average middle elements lenght was 6.64 mm by crushed varieties.

  4. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  5. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Directory of Open Access Journals (Sweden)

    Rumen Kostadinov

    2016-04-01

    Full Text Available When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  6. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Science.gov (United States)

    Kostadinov, Rumen; Maley, Carlo C; Kuhner, Mary K

    2016-04-01

    When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  7. [Fatal incidents by crowd crush during mass events. (Un)preventable phenomenon?].

    Science.gov (United States)

    Wagner, U; Fälker, A; Wenzel, V

    2013-01-01

    Crowd crushes with dozens or even hundreds of casualties have occurred several times at the Hajj in Saudi Arabia and also in soccer stadiums in Western Europe. As fatal accidents after human stampedes during mass events occur very rarely and are usually accompanied by many years of criminal court proceedings in order to identify underlying responsible mechanisms and culprits, it is very difficult to draw conclusions and formulate precautions from an emergency medical point of view. This study analyzed a fatal crowd crush which occurred on 4 December 1999 following the "Air & Style" snowboard contest with approximately 22,000 people attending in the Bergisel stadium in Innsbruck, Austria. Firstly, focused interviews were conducted with professional rescuers, police and physicians and secondly publicly available court records dealing with this incident in the district court of Innsbruck, Austria were analyzed. During the snowboard contest 87 emergency medical technicians, 6 emergency physicians, 1 leading emergency physician, 21 policemen and 140 security personnel were present. Following the accident additionally some 100 emergency medical technicians, 36 emergency medical service vehicles and 4 physician-staffed emergency medical service vehicles responded to the scene. The deadly crowd crush resulting in 6 fatalities, 4 patients still in a vegetative state and 38 injured, was due to a severe crowd accumulation at one stadium exit, which was not recognized and dispersed in time. Construction of the exit in line with darkness, steep slope and slippery surface contributed adversely to this dangerous situation, although panic did not occur at any time. Unfortunately, there is no patent remedy to completely prevent fatal accidents by a crowd crush at mass events. If planning is initiated early, sufficient material and personnel reserves are kept in reserve and despite conflicting interests of the organizers, the host community, security, police and emergency medical

  8. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  9. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya ... In the context of weak regulatory enforcement, worksite health and safety ... in stone quarrying and crushing through better ecosystem management. ... India, Central Asia, Far East Asia, South Asia ... LVIF announces five more funded projects.

  10. Concrete manufactured with crushed asphalt as partial replacement of natural aggregates

    Directory of Open Access Journals (Sweden)

    L. Coppola

    2016-09-01

    Full Text Available The paper focuses on the reuse of crushed asphalt (GA as a partial replacement (up to 20% of natural aggregates for concrete manufacture. Addition of GA aggregates produced a positive effect on workability loss. The GA mixes, however, showed a significant tendency to bleed and segregate at the highest replacement percentage applied. GA led to a decrease of compressive strength in concrete (with respect to that of the reference concrete up to 50% due to the weakness of the cement paste / recycled aggregate interface. To compensate for this negative effect, a reduction of w/c for the GA concretes was necessary. A decrease of w/c allowed the GA concretes to show drying shrinkage values substantially similar to those of reference concrete with the same cement factor. The experimental results confirmed the possibility of partial substitution (max. 15% of natural aggregates with crushed asphalt for making concrete.

  11. Acute sciatic nerve crush injuries in rabbits: MRI and pathological comparative study

    International Nuclear Information System (INIS)

    Li Xinchun; Chen Jianyu; Wang Xinlu; Shen Jun; Liu Qingyu; Liang Biling

    2004-01-01

    Objective: Simulating injury mechanism in human peripheral nerve, acute sciatic nerve crush injuries model was produced in rabbits to investigate the relationship between the manifestations of MRI and pathology in order to provide the information for clinical therapy and operative plan. Methods: Thirty-two adult rabbits were randomly divided into two groups: group A (n=16) and B (n=16). In group A, the left sciatic nerves were crushed with a stress of 3.61 kg; In group B, with a stress of 10.50 kg. 4 time intervals in each group were observed in 1, 2, 4, and 8 weeks, respectively, and each time interval contained 4 rabbits. Left sciatic nerves were served as injured sides, right sciatic nerves were regarded as control sides. MRI was performed at different time interval after crush injury. Then the nerves were examined pathologically. Results: There were no obvious changes on T 1 WI in injured sides, but the injured distal segment of sciatic nerve thickened and twisted, showing high signal intensity on 3D T 2 WI, T 2 WI/SPIR, B-FFE, and T 2 WI/STIR. MRI could show abnormality of 30 sciatic nerves, the correct diagnostic rate was 93.75% and false negative rate was 6.25%. The distal sciatic nerve/muscle signal intensity ratio (SIR) of the injured sides was significantly higher than that of the control sides (P 0.05). SIR in injured side increased at 1 week, reached the peak at 2 weeks, at this time, nerve axons disappeared and lots of myelin degenerated, abduction function disappeared. SIR decreased during 4-8 weeks, the myelin sheath breakdown and Schwann cell proliferated obviously, and abduction functions were observed. The control sciatic nerves showed no abnormality in MRI and pathology. Conclusion: MRI can make the diagnosis of crush injury of sciatic nerve, and dynamic SIR measurement of nerve injury correlates well with the pathological and functional recovery process. MRI is an effective method to monitor degeneration, regeneration, and prognosis after

  12. Remaining porosity and permeability of compacted crushed rock salt backfill in a HLW repository. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Jobmann, M.; Mueller, C.; Schirmer, S.

    2015-11-15

    The safe containment of radioactive waste is to be ensured by the geotechnical barriers in combination with the containment-providing rock zone (CRZ). The latter is a key element of the recently developed concept of demonstrating the integrity of the geologic barrier (Krone et al., 2013). As stipulated in the safety requirements of the regulating body the CRZ has to have strong barrier properties, and evidence needs to be provided that it retains its integrity throughout the reference period (BMU, 2010). The underground openings excavated in the rock salt will close over time due to the creep properties of the rock salt. This process causes deformations in the surrounding rock salt, which leads to a change in stress state in the virgin rock and may impair the integrity of the containment-providing rock zone. In order to limit the effects of these processes, all underground openings will be backfilled with crushed salt. Immediately after backfilling, the crushed salt will have an initial porosity of approx. 35%, which - over time - will be reduced to very low values due to the creep properties of the rock salt. The supporting pressure that builds up in the crushed salt with increasing compaction slows down the creeping of the salt. Major influencing factors are the temperature (with higher temperatures accelerating the salt creeping) and the moisture of the salt, which - due to the related decrease in the resistance of the crushed salt - facilitates its compaction. The phenomenology of these processes and dependencies is understood to a wide extent. This project investigated the duration until compaction is completed and when and under what circumstances the crushed salt will have the sealing properties necessary to ensure safe containment. Thermo-hydro-mechanical (THM) processes play a crucial role in determining whether solutions which might enter the mine could reach the radioactive waste. This includes changes in material behaviour due to a partial or complete

  13. The role of Facebook in Crush the Crave, a mobile- and social media-based smoking cessation intervention: qualitative framework analysis of posts.

    Science.gov (United States)

    Struik, Laura Louise; Baskerville, Neill Bruce

    2014-07-11

    Social networking sites, particularly Facebook, are increasingly included in contemporary smoking cessation interventions directed toward young adults. Little is known about the role of Facebook in smoking cessation interventions directed toward this age demographic. The aim of this study was to characterize the content of posts on the Facebook page of Crush the Crave, an evidence-informed smoking cessation intervention directed toward young adults aged 19 to 29 years. Crush the Crave Facebook posts between October 10, 2012 and June 12, 2013 were collected for analysis, representing page activity during the pilot phase of Crush the Crave. Of the 399 posts included for analysis, 121 were original posts, whereas the remaining 278 were reply posts. Posts were coded according to themes using framework analysis. We found that the original Crush the Crave Facebook posts served two main purposes: to support smoking cessation and to market Crush the Crave. Most of the original posts (86/121, 71.1%) conveyed support of smoking cessation through the following 7 subthemes: encouraging cessation, group stimulation, management of cravings, promoting social support, denormalizing smoking, providing health information, and exposing tobacco industry tactics. The remaining original posts (35/121, 28.9%) aimed to market Crush the Crave through 2 subthemes: Crush the Crave promotion and iPhone 5 contest promotion. Most of the reply posts (214/278, 77.0%) were in response to the supporting smoking cessation posts and the remaining 64 (23.0%) were in response to the marketing Crush the Crave posts. The most common response to both the supporting smoking cessation and marketing Crush the Crave posts was user engagement with the images associated with each post at 40.2% (86/214) and 45% (29/64), respectively. The second most common response consisted of users sharing their smoking-related experiences. More users shared their smoking-related experiences in response to the supporting

  14. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya Pradesh), stone quarrying and crushing is carried out by labor-intensive units employing unskilled workers on a seasonal basis complementing the agricultural cycle. In the context of weak regulatory enforcement, worksite health and safety ...

  15. Cross-section crushing behaviour of hat-sections (Part II: Analytical modelling)

    NARCIS (Netherlands)

    Hofmeyer, H.

    2005-01-01

    Hat-sections are often used to experimentally investigate building sheeting subject to a concentrated load and bending. In car doors, hat-sections are used for side-impact protection. Their crushing behaviour can partly be explained by only observing their cross-sectional behaviour [1]. This

  16. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  17. An Optic Nerve Crush Injury Murine Model to Study Retinal Ganglion Cell Survival

    Science.gov (United States)

    Tang, Zhongshu; Zhang, Shuihua; Lee, Chunsik; Kumar, Anil; Arjunan, Pachiappan; Li, Yang; Zhang, Fan; Li, Xuri

    2011-01-01

    Injury to the optic nerve can lead to axonal degeneration, followed by a gradual death of retinal ganglion cells (RGCs), which results in irreversible vision loss. Examples of such diseases in human include traumatic optic neuropathy and optic nerve degeneration in glaucoma. It is characterized by typical changes in the optic nerve head, progressive optic nerve degeneration, and loss of retinal ganglion cells, if uncontrolled, leading to vision loss and blindness. The optic nerve crush (ONC) injury mouse model is an important experimental disease model for traumatic optic neuropathy, glaucoma, etc. In this model, the crush injury to the optic nerve leads to gradual retinal ganglion cells apoptosis. This disease model can be used to study the general processes and mechanisms of neuronal death and survival, which is essential for the development of therapeutic measures. In addition, pharmacological and molecular approaches can be used in this model to identify and test potential therapeutic reagents to treat different types of optic neuropathy. Here, we provide a step by step demonstration of (I) Baseline retrograde labeling of retinal ganglion cells (RGCs) at day 1, (II) Optic nerve crush injury at day 4, (III) Harvest the retinae and analyze RGC survival at day 11, and (IV) Representative result. PMID:21540827

  18. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. [The neuroprotective effect of erigeron breviscapus (vant) hand-mazz on retinal ganglion cells after optic nerve crush injury].

    Science.gov (United States)

    Jiang, Bing; Jiang, You-qin

    2003-08-01

    To investigate whether a Chinese herbal medicine, erigeron breviscapus (vant) hand-mazz (EBHM), can protect the retinal ganglion cells (RGC) damaged by calibrated optic nerve crush injury. Forty-two Sprague-Dawley rats were randomly divided into two groups. Calibrated optic nerve crush injury model was induced in the right eyes by a special designed optic nerve clip. The left eyes served as a control. All 42 rats were randomly divided into 2 groups. Group A consisted of the rats with calibrated optic nerve crush injury and group B consisted of rats with calibrated optic nerve crush injury treated with EBHM. In group B, EBHM solution was given once after the crush injury. According to the time interval between the optic nerve crush and the sacrifice, both groups A and B were further divided into three subgroups (day 4, day 14 and day 21). Therefore, there were 7 rats in each subgroup. Three days before sacrifice, 3% fast blue was injected into superior colliculi bilaterally. The eyes were enucleated after the rat was sacrificed, and flat mounts of the retina from both eyes were prepared on a slide and observed under a fluorescence microscope. Four photos with 400 x magnification were taken from each of the four quadrants of the retina 1 mm away from the optic disc. The labeled RGC were counted by a computerized image analyzer. The labeled RGC rate was used for statistical analysis (the labeled RGC rate = number of RGC in injured eye/control eye x 100%). In group A, the labeled RGC rate was (77.79 +/- 7.11)%, (63.76 +/- 3.79)% and (54.66 +/- 4.75)% on day 4, day 14 and day 21, respectively. In group B, the labeled RGC rate was (80.13 +/- 12.03)%, (78.17 +/- 9.19)% and (83.59 +/- 12.61)% on day 4, day 14 and day 21, respectively. In group B, which was treated with EBHM after injury, the labeled RGC rate was significantly higher than that of group A on day 14 and day 21. In the experimental optic nerve crush model in rats, EBHM therapy can increase the survival rate of

  20. The diffusivity of cesium, strontium, carbon and nickel in concrete and mixtures of sodium bentonite and crushed rock

    International Nuclear Information System (INIS)

    Muurinen, A.; Penttilae-Hiltunen, P.; Rantanen, J.

    1986-07-01

    The engineering barriers suggested to be used for the disposal of low and intermediate level wastes in Finland are concrete and crushed rock or mixtures of crushed rock and bentonite. In the repository the barriers are saturated by groundwater and radionuclides may be released by diffusion through the barries. For safety analysis, the mechanisms by which the nuclides migrate and corresponding parameters should be known. In this study diffusion measurements on different types of concrete and mixtures of sodium bentonite and crushed rock were carried out. Radioactive isotopes of cesium, strontium, carbon and nickel were used as tracers. The apparent diffusivities (Dsub(a)) were evaluated on the basis of the measurements. The apparent diffusivity of cesium in concretes was 10 -14 ...10 -15 m 2 /s. Strontium was mainly sorbed on cement where it diffuses slowly. Part of strontium propably penetrates in the rock ballast by diffusion. The diffusivities of carbon and nickel in the concrete was low. The upper limit was evaluated to be Dsub(a) -14 m 2 /s. The diffusivity of cesium in the mixtures of crushed rock and bentonite varies between 0.5x10 -12 and 7x10 -12 m 2 /s. Cesium was mainly sorbed on the rock. The diffusivity of strontium was 2x10 -11 ...2x10 -12 m 2 /s. Strontium was mainly sorbed on bentonite. The diffusion of the sorbed ions (surface diffusion) seems to be a additional migration mechanism in the case of cesium and strontium in the mixture of bentonite and crushed rock. The diffusivity of carbon in the mixtures of crushed rock and bentonite was 6x10 -11 ...4x10 -12 m 2 /s. No sorption was found in the case of carbon. The measured Dsub(a) of nickel in the mixtures of crushed rock and bentonite was 4x10 -14 ...2x10 -15 m 2 /s. The experimental arrangement was not, however, in the stationary state and the more correct values would propably be 10 -13 ...10 -14 m 2 /s. No surface diffusion was found in the case of nickel. (author)

  1. Crushing leads to waste disposal savings for FUSRAP

    Energy Technology Data Exchange (ETDEWEB)

    Darby, J. [Department of Energy, Oak Ridge, TN (United States)

    1997-02-01

    In this article the author discusses the application of a rock crusher as a means of implementing cost savings in the remediation of FUSRAP sites. Transportation and offsite disposal costs are at present the biggest cost items in the remediation of FUSRAP sites. If these debris disposal problems can be handled in different manners, then remediation savings are available. Crushing can result in the ability to handle some wastes as soil disposal problems, which have different disposal regulations, thereby permitting cost savings.

  2. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  3. Rapid detection of toxic metals in non-crushed oyster shells by portable X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chou Ju, E-mail: Ju.Chou@selu.ed [Department of Chemistry and Physics, Southeastern Louisiana University, Hammond, LA 70402 (United States); Clement, Garret; Bursavich, Bradley; Elbers, Don [Department of Chemistry and Physics, Southeastern Louisiana University, Hammond, LA 70402 (United States); Cao Baobao; Zhou Weilie [Advanced Material Research Institute, University of New Orleans, New Orleans, LA 70148 (United States)

    2010-06-15

    The aim of this study was the multi-elemental detection of toxic metals such as lead (Pb) in non-crushed oyster shells by using a portable X-ray fluorescence (XRF) spectrometer. A rapid, simultaneous multi-element analytical methodology for non-crushed oyster shells has been developed using a portable XRF which provides a quick, quantitative, non-destructive, and cost-effective mean for assessment of oyster shell contamination from Pb. Pb contamination in oyster shells was further confirmed by scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS). The results indicated that Pb is distributed in-homogeneously in contaminated shells. Oyster shells have a lamellar structure that could contribute to the high accumulation of Pb on oyster shells. - A rapid, simultaneous multi-element analytical methodology for non-crushed oyster shells has been developed using XRF and contamination of lead on oyster shells was confirmed by XRF and SEM-EDS.

  4. Rapid detection of toxic metals in non-crushed oyster shells by portable X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Chou Ju; Clement, Garret; Bursavich, Bradley; Elbers, Don; Cao Baobao; Zhou Weilie

    2010-01-01

    The aim of this study was the multi-elemental detection of toxic metals such as lead (Pb) in non-crushed oyster shells by using a portable X-ray fluorescence (XRF) spectrometer. A rapid, simultaneous multi-element analytical methodology for non-crushed oyster shells has been developed using a portable XRF which provides a quick, quantitative, non-destructive, and cost-effective mean for assessment of oyster shell contamination from Pb. Pb contamination in oyster shells was further confirmed by scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS). The results indicated that Pb is distributed in-homogeneously in contaminated shells. Oyster shells have a lamellar structure that could contribute to the high accumulation of Pb on oyster shells. - A rapid, simultaneous multi-element analytical methodology for non-crushed oyster shells has been developed using XRF and contamination of lead on oyster shells was confirmed by XRF and SEM-EDS.

  5. Mechanical and hydraulic behaviour of compacting crushed salt backfill at low porosities. Project REPOPERM. Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Kroehn, Klaus-Peter; Czaikowski, Oliver; Wieczorek, Klaus; Zhang, Chun-Liang; Moog, Helge; Friedenberg, Larissa [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Koeln (Germany); Stuehrenberg, Dieter; Heemann, Ulrich [Bundesanstalt fuer Geowissenschaften und Rohstoffe (BGR), Hannover (Germany); Jobmann, Michael; Mueller, Christian; Schirmer, Sonja [DBE Technology GmbH (DBE TEC), Peine (Germany)

    2017-02-15

    The compaction behavior of crushed salt has been extensively investigated by means of experimental as well as theoretical work. The readiness of numerical tools for the application to modeling the complex coupled thermo-hydro-mechanical processes in the crushed salt backfilled in a repository in salt rock has also been demonstrated. Compaction tests were performed under repository-relevant conditions. These tests were supplemented by laboratory work aiming at specific aspects of compaction. The following list covers the topics of these investigations as well as the main results. - Revisiting the determination of the porosity in relevant, past experiments (BGR). - Influence of the grain size distribution on compaction (BGR). - Triaxial compaction test with dry material at low porosities (BGR). - Investigation of the influence of humidity on compaction covers several subtopics. - Permeability associated with low porosity includes two subtopics. - Constitutive equations for two -phase flow (GRS). - Microstructural Investigations (DBE TEC). Parallel to the experimental work attention focussed on several aspects of the basics for modelling the compaction of crushed salt. This work covers checking the validity of the established numerical tools as well as exploring new methods. Topics and main results are listed here: - Development/definition and comparison of constitutive models (BGR). - Benchmark calculations (BGR and GRS). - Capability of scaling-rules for capillary pressure from the oil industry (GRS). - Application of discrete element codes to compacting crushed salt (DBE TEC). Finally, repository-relevant scenarios are discussed as a basis for a realistic but generic numerical model of brine inflow in to a converging back filled drift under a thermal gradient (GRS). This exercise demonstrates the feasibility of modelling crushed salt compaction as a fully coupled thermohydraulic-mechanical process including two-phase flow effects.

  6. Mechanical and hydraulic behaviour of compacting crushed salt backfill at low porosities. Project REPOPERM. Phase 2

    International Nuclear Information System (INIS)

    Kroehn, Klaus-Peter; Czaikowski, Oliver; Wieczorek, Klaus; Zhang, Chun-Liang; Moog, Helge; Friedenberg, Larissa; Stuehrenberg, Dieter; Heemann, Ulrich; Jobmann, Michael; Mueller, Christian; Schirmer, Sonja

    2017-02-01

    The compaction behavior of crushed salt has been extensively investigated by means of experimental as well as theoretical work. The readiness of numerical tools for the application to modeling the complex coupled thermo-hydro-mechanical processes in the crushed salt backfilled in a repository in salt rock has also been demonstrated. Compaction tests were performed under repository-relevant conditions. These tests were supplemented by laboratory work aiming at specific aspects of compaction. The following list covers the topics of these investigations as well as the main results. - Revisiting the determination of the porosity in relevant, past experiments (BGR). - Influence of the grain size distribution on compaction (BGR). - Triaxial compaction test with dry material at low porosities (BGR). - Investigation of the influence of humidity on compaction covers several subtopics. - Permeability associated with low porosity includes two subtopics. - Constitutive equations for two -phase flow (GRS). - Microstructural Investigations (DBE TEC). Parallel to the experimental work attention focussed on several aspects of the basics for modelling the compaction of crushed salt. This work covers checking the validity of the established numerical tools as well as exploring new methods. Topics and main results are listed here: - Development/definition and comparison of constitutive models (BGR). - Benchmark calculations (BGR and GRS). - Capability of scaling-rules for capillary pressure from the oil industry (GRS). - Application of discrete element codes to compacting crushed salt (DBE TEC). Finally, repository-relevant scenarios are discussed as a basis for a realistic but generic numerical model of brine inflow in to a converging back filled drift under a thermal gradient (GRS). This exercise demonstrates the feasibility of modelling crushed salt compaction as a fully coupled thermohydraulic-mechanical process including two-phase flow effects.

  7. Clinical impact of bladder biopsies with TUR-BT according to cytology results in patients with bladder cancer: a case control study

    Directory of Open Access Journals (Sweden)

    Matsumoto Kazuhiro

    2010-06-01

    Full Text Available Abstract Background There seems to be no consensus concerning taking bladder biopsies during transurethral resection of bladder tumor (TUR-BT. We investigate the clinical significance of bladder biopsy with TUR-BT and the relationship between urinary cytology and the biopsy results. Methods We reviewed a total of 424 patients with non-muscle invasive bladder cancer treated with TUR-BT between 1998 and 2005. Of the total, 293 patients also underwent a bladder biopsy. Biopsies from suspicious-appearing urothelium (N = 59 and those from normal-appearing urothelium (N = 234 were evaluated separately. Results Bladder cancer was observed in 23 cases (39.0% who underwent a biopsy of suspicious-appearing urothelium. Among these 23 cases, 9 cases with visible tumor resection had carcinoma in situ (CIS only in the biopsies from suspicious-appearing urothelium. Urinary cytology was negative in 3 of the 9 cases. Bladder cancer was observed in 26 cases (11.1% who underwent a biopsy of normal-appearing urothelium. Of them, 5 cases with visible tumors had CIS only in the multiple biopsies from normal-appearing urothelium. Urinary cytology was positive in all of the 5 cases. No upstaging or upgrading cases were found in these patients by the addition of these two types of biopsy. Furthermore, therapy was not altered in these patients. With or without bladder biopsy was not a significant factor for tumor recurrence in either the univariate or multivariate analysis. Conclusions Based on the results, it is concluded the multiple biopsies from normal-appearing urothelium are not necessary in patients with negative cytology results because of the low detection rate and lack of influence on therapeutic decisions. Meanwhile, biopsy of suspicious-appearing urothelium is needed in patients with negative cytology results in order to detect CIS due to staging properties. This result supports a recent EAU guideline.

  8. Exploratory study of crushed coconut shell as partial replacement for ...

    African Journals Online (AJOL)

    The trend shows a decrease in strength as the quantity of CCS in the concrete cubes increases. The workability of the concrete decreased as the quantity of CSS increased with the mould slumping at 100% CSS. Aggregate Crushing Value (ACV) for CSS is 8% and that for fine sand is 17.89%,, while Aggregate Impact ...

  9. Stereotactic core needle breast biopsy marker migration: An analysis of factors contributing to immediate marker migration.

    Science.gov (United States)

    Jain, Ashali; Khalid, Maria; Qureshi, Muhammad M; Georgian-Smith, Dianne; Kaplan, Jonah A; Buch, Karen; Grinstaff, Mark W; Hirsch, Ariel E; Hines, Neely L; Anderson, Stephan W; Gallagher, Katherine M; Bates, David D B; Bloch, B Nicolas

    2017-11-01

    To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors. This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration. Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration. Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration. • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.

  10. Crushing Candy: The Free-to-Play Game in Its Connective Commodity Form

    Directory of Open Access Journals (Sweden)

    David B. Nieborg

    2015-12-01

    Full Text Available The goal of this article is to add a complementary perspective to the study of social network sites by surveying how the political economy of social media platforms relates to the structure of free-to-play games in their commodity form. Drawing on the theory of multisided markets and critical political economy, this article surveys the political economy of game apps and investigates how it is symbiotically related to the technological and economic logic underlying connective platforms operated by Google, Apple, Facebook, and Amazon. These social media platforms operate app stores that sustain the transformation of games as fixed, physically distributed products that follow a transaction logic, into digitally distributed, freely accessible, or “free-to-play” apps. Through a case study of the popular casual game Candy Crush Saga it is contended that the connective properties of social media platforms affect the form and format of game apps as cultural commodities. Candy Crush Saga developer King Digital Entertainment has been able to attract hundreds of millions of players and build a business model that combines the commodification of virtual items, connectivity, user attention, user data, and play. It is argued that the free-to-play commodity form comprises three commodity types: the product commodity, the “prosumer commodity,” and the player commodity. Furthermore, Candy Crush Saga ’s commodity form is structured by a platformed modality of cultural production and circulation and therefore embedded in the political economy of its host platform.

  11. Sudden multiple fractures in a patient with sarcoidosis in multiple organs.

    Science.gov (United States)

    Sada, Mitsuru; Saraya, Takeshi; Ishii, Haruyuki; Goto, Hajime

    2014-04-07

    A 30-year-old man who incidentally fractured his right olecranon and other multiple phalanges was admitted to our hospital. He had a 2-year history of uveitis and bilateral hilar lymphadenopathy (BHL), and pulmonary sarcoidosis was diagnosed from transbronchial lung biopsy. Right elbow arthrodesis was performed, and biopsied specimens showed non-caseating epithelioid cell granuloma, suggesting osseous sarcoidosis. He was discharged uneventfully without further treatment, but BHL had progressed with the appearance of lung parenchymal lesions 3 months later. At that time, involvement of other organs was also noted on Gallium-67 scintigraphy, showing accumulations in BHL, axillary and inguinal lymph nodes, enlarged liver and spleen and subcutaneous areas. After initiation of steroid therapy, multiple organ involvement improved, and no further bone involvement has been recognised to date. Osseous sarcoidosis complicated by bone fracture is an extremely rare presentation, but should be considered in patients with sarcoidosis, especially when multiple organs are involved.

  12. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  13. Obstructive jaundice: a comparative study of forceps and brush biopsy under percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Li Yongdong; Han Xinwei; Wu Gang; Ma Bo; Xing Gusheng

    2004-01-01

    Objective: To compare the sensitivity between forceps biopsy and brushing, and to explore a feasible approach to pathological diagnosis of the obstructive jaundice. Methods: 92 consecutive patients with obstructive jaundice underwent transluminal forceps biopsy and brushing during percutaneous transhepatic cholangiography and percutaneous transhepatic cholangiodrainage. The technique was performed through a preexisting percutaneous transhepatic tract with multiple specimens obtained after passing the forceps biopsy or brush into a 8-French sheath. Finally the specimens were fixed with formalin for pathologic or cytologic diagnosis. Results: The histopathologic diagnosis was acquired in 81 out of 92 patients with forceps biopsy reaching the successful rate of 97.83%. Sensitivity of forceps biopsy in 92 patients was higher than that of brush in 84 patients (88.04% vs 76.19% χ 2 =4.251, P= <0.05). Conclusions: Percutaneous transhepatic cholangiobiopsy is a simple technique with minimal invasion, high sensitivity and worthy to be used spread extensively. Percutaneous transluminal brush cytology is also an useful method for establishing a diagnosis of cholangiocarcinoma. (authors)

  14. A study on the crushing behavior of basalt fiber reinforced composite structures

    Science.gov (United States)

    Pandian, A.; Veerasimman, A. P.; Vairavan, M.; Francisco, C.; Sultan, M. T. H.

    2016-10-01

    The crushing behavior and energy absorption capacity of basalt fiber reinforced hollow square structure composites are studied under axial compression. Using the hand layup technique, basalt fiber reinforced composites were fabricated using general purpose (GP) polyester resin with the help of wooden square shaped mould of varying height (100 mm, 150 mm and 200 mm). For comparison, similar specimens of glass fiber reinforced polymer composites were also fabricated and tested. Axial compression load is applied over the top end of the specimen with cross head speed as 2 mm/min using Universal Testing Machine (UTM). From the experimental results, the load-deformation characteristics of both glass fiber and basalt fiber composites were investigated. Crashworthiness and mode of collapse for the composites were determined from load-deformation curve, and they were then compared to each other in terms of their crushing behaviors.

  15. Reducing the startup time of aerobic granular sludge reactors through seeding floccular sludge with crushed aerobic granules.

    Science.gov (United States)

    Pijuan, Maite; Werner, Ursula; Yuan, Zhiguo

    2011-10-15

    One of the main challenging issues for the aerobic granular sludge technology is the long startup time when dealing with real wastewaters. This study presents a novel strategy to reduce the time required for granulation while ensuring a high level of nutrient removal. This new approach consists of seeding the reactor with a mixture of crushed aerobic granules and floccular sludge. The effectiveness of the strategy was demonstrated using abattoir wastewater, containing nitrogen and phosphorus at approximately 250 mgN/L and 30 mgP/L, respectively. Seven different mixtures of crushed granules and floccular sludge at granular sludge fractions (w/w in dry mass) of 0%, 5%, 10%, 15%, 25%, 30% and 50% were used to start eight granulation processes. The granulation time (defined as the time when the 10th percentile bacterial aggregate size is larger than 200 μm) displayed a strong dependency on the fraction of granular sludge. The shortest granulation time of 18 days was obtained with 50% crushed granules, in comparison with 133 days with 5% crushed granules. Full granulation was not achieved in the two trials without seeding with crushed granules. In contrast to the 100% floccular sludge cases, where a substantial loss of biomass occurred during granulation, the biomass concentration in all other trails did not decrease during granulation. This allowed that good nitrogen removal was maintained in all the reactors during the granulation process. However, enhanced biological phosphorus removal was achieved in only one of the eight trials. This was likely due to the temporary accumulation of nitrite, a strong inhibitor of polyphosphate accumulating organisms. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  17. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    Science.gov (United States)

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (Pstrategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  18. Administration of Oxygen Ultra-Fine Bubbles Improves Nerve Dysfunction in a Rat Sciatic Nerve Crush Injury Model

    Directory of Open Access Journals (Sweden)

    Hozo Matsuoka

    2018-05-01

    Full Text Available Ultra-fine bubbles (<200 nm in diameter have several unique properties and have been tested in various medical fields. The purpose of this study was to investigate the effects of oxygen ultra-fine bubbles (OUBs on a sciatic nerve crush injury (SNC model rats. Rats were intraperitoneally injected with 1.5 mL saline, OUBs diluted in saline, or nitrogen ultra-fine bubbles (NUBs diluted in saline three times per week for 4 weeks in four groups: (1 control, (sham operation + saline; (2 SNC, (crush + saline; (3 SNC+OUB, (crush + OUB-saline; (4 SNC+NUB, (crush + NUB-saline. The effects of the OUBs on dorsal root ganglion (DRG neurons and Schwann cells (SCs were examined by serial dilution of OUB medium in vitro. Sciatic functional index, paw withdrawal thresholds, nerve conduction velocity, and myelinated axons were significantly decreased in the SNC group compared to the control group; these parameters were significantly improved in the SNC+OUB group, although NUB treatment did not affect these parameters. In vitro, OUBs significantly promoted neurite outgrowth in DRG neurons by activating AKT signaling and SC proliferation by activating ERK1/2 and JNK/c-JUN signaling. OUBs may improve nerve dysfunction in SNC rats by promoting neurite outgrowth in DRG neurons and SC proliferation.

  19. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya ... In the context of weak regulatory enforcement, worksite health and safety measures are not ... involved in stone quarrying and crushing through better ecosystem management. ... et les défis futurs dans la communauté économique de l'ASEAN.

  20. Interim design report: fuel particle crushing

    International Nuclear Information System (INIS)

    Baer, J.W.; Strand, J.B.; Cook, E.J.; Miller, C.M.

    1977-11-01

    The double-roll fuel particle crusher was developed to fracture the silicon carbide coatings of Fort St. Vrain (FSV) fertile and fissile and large high-temperature gas-cooled reactor (LHTGR) fissile fuel particles. The report details the design task for the fuel particle crusher, including historical test information on double-roll crushers for carbide-coated fuels and the design approach selected for the cold pilot plant crusher, and shows how the design addresses the equipment goals and operational objectives. Design calculations and considerations are included to support the selection of crusher drive and gearing, the materials chosen for crushing rolls and housing, and the bearing selection. The results of the initial testing for compliance with design objectives and operational capabilities are also presented. 8 figures, 4 tables

  1. MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

    International Nuclear Information System (INIS)

    Thompson, Scott M.; Gorny, Krzysztof R.; Jondal, Danielle E.; Rech, Karen L.; Mardini, Samir; Woodrum, David A.

    2017-01-01

    A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

  2. MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Gorny, Krzysztof R.; Jondal, Danielle E. [Mayo Clinic College of Medicine, Department of Radiology (United States); Rech, Karen L. [Mayo Clinic College of Medicine, Department of Laboratory Medicine and Pathology (United States); Mardini, Samir [Mayo Clinic College of Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery (United States); Woodrum, David A. [Mayo Clinic College of Medicine, Division of Vascular and Interventional Radiology, Department of Radiology (United States)

    2017-01-15

    A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

  3. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  4. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  5. Effect of crumb rubber on the mechanical properties of crushed recycled pavement materials.

    Science.gov (United States)

    Li, Jie; Saberian, Mohammad; Nguyen, Bao Thach

    2018-07-15

    The low-carbon footprint of using recycled construction and demolition (C&D) aggregates in civil engineering infrastructure applications has been considered to be a significant solution for the replacement of conventional pavement aggregates. Investigations regarding the use of crumb rubber in the base and subbase layers of pavement have been well documented. However, information on the effects of crumb rubber and its size within C&D aggregates as the base/subbase layers is still very limited. In this study, crumb rubber with particle sizes ranging from 400 to 600 μm (fine) to 10-15 mm (coarse), 20 mm recycled crushed concrete (RCC), and 20 mm crushed rock (CR) were used. The crumb rubber was added to the two groups of C&D aggregates at 0.5, 1 and 2% by weight percentages of the aggregates. The effect of crumb rubber on the mechanical properties (such as California bearing ratio, unconfined compressive strength, aggregate crushing value, dynamic lightweight cone penetrometer, Clegg impact value, Los Angeles abrasion values, and resilient modulus) of the C&D aggregates was then examined. Based on the experimental test results, it was found that crumb rubber can be recycled as a waste material for the base and subbase layers in the pavement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  7. Use of waste crushed glass for the production of hot-mix asphalt

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2016-08-01

    Full Text Available presents the development and evaluation of a new asphalt concrete mix that utilizes a sustainable crushed glass as a replacement material of a natural aggregate. The ultimate goal is to produce a cost-effective asphalt wearing course with comparative...

  8. The Chances of Subsequent Cancer Detection in Patients with a PSA > 20 ng/ml and an Initial Negative Biopsy

    Directory of Open Access Journals (Sweden)

    Nadeem Shaida

    2009-01-01

    Full Text Available Transrectal ultrasound (TRUS–guided prostate biopsy is known to carry a significant false-negative rate, leading some patients to have multiple biopsies. We investigated cancer detection rates in patients with a PSA >20 ng/ml and a negative initial biopsy. We reviewed our database of 2396 TRUS-guided biopsies done between 1997 and 2002 in order to give a follow-up of at least 6 years. PSA, PSA density (PSAD, PSA velocity (PSAV, prostate volume, and DRE findings were analysed in relation to cancer status. Of the patients, 388 (16% had a PSA >20 ng/ml, including 99 (26% with benign biopsies. Of those, 67 were rebiopsied, including 19 (28% with cancer on the first rebiopsy and four (6% on further biopsies. PSAD, DRE, and volume significantly differed between rebiopsied patients with and without cancer (p 20 ng/ml and have an initial negative biopsy have a high chance of malignancy being detected on a second biopsy. However, if a second biopsy is also negative, then the chances of subsequent biopsies showing signs of cancer are very low if the DRE is normal and particularly if the PSAD is >0.35 ng/ml/cm3.

  9. Influence of technical parameters of disk-shaped reactor on productivity of heat treatment of crushed wood

    Science.gov (United States)

    Safin, R. R.; Khasanshin, R. R.; Mukhametzyanov, S. R.

    2018-03-01

    The existing installations for heat treatment of the crushed wood are analyzed. The technology of heat treatment of the crushed wood in the devices of disk-shaped type is offered. The results of modeling for the purpose of determination of interrelation of the key design and technological parameters of the disk-shaped device are presented. It is established that the major factors, affecting duration of stay of the material in a device, are the speed of rotation of the mixer, the number of mixers and the number of rakes on the mixer.

  10. Multiple locations of nerve compression: an unusual cause of persistent lower limb paresthesia.

    Science.gov (United States)

    Ang, Chia-Liang; Foo, Leon Siang Shen

    2014-01-01

    A paucity of appreciation exists that the "double crush" phenomenon can account for persistent leg symptoms even after spinal neural decompression surgery. We present an unusual case of multiple locations of nerve compression causing persistent lower limb paresthesia in a 40-year old male patient. The patient's lower limb paresthesia was persistent after an initial spinal surgery to treat spinal lateral recess stenosis thought to be responsible for the symptoms. It was later discovered that he had peroneal muscle herniations that had caused superficial peroneal nerve entrapments at 2 separate locations. The patient obtained much symptomatic relief after decompression of the peripheral nerve. The "double crush" phenomenon and multiple levels of nerve compression should be considered when evaluating lower limb neurogenic symptoms, especially after spinal nerve root surgery. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Wastes disposal on board a ship. Crushing and volume reducing apparatus for combustible and non-combustible refuses; Senjo no haikibutsu shori. Kanen funen gomi no hasai gen`yo shori sochi

    Energy Technology Data Exchange (ETDEWEB)

    Kishida, Y. [Hitachi Zosen Corp., Osaka (Japan)

    1996-07-25

    This paper introduces a refuse crushing apparatus to reduce for storage the volume of refuses produced on board a ship by crushing. Refuses to be crushed are solid wastes including solid combustible refuses such as paper, wood pieces, and cloths, non-combustible refuses such as empty cans, metals and glass, and refuses unsuitable for combustion, such as plastics and stylofoam. Crushing methods include impact system, compression system and shearing system. The shearing system shears and crushes refuses by using blades rotating at a low speed. The system has a wide range of crush ability and excellent versatility, generates low levels of dust, noise and vibration, and is suitable as a marine use refuse disposing apparatus. However, empty cans and PET bottles are more difficult of getting into cutting blades requiring a large amount of time for crushing. Therefore, it is more suitable to reduce volume of refuses by using a compressor or the like apparatuses, and then crush them by using a double-axial shearing crusher. Stylofoam causes its crushed pieces to be electrically charged and deposited onto the apparatus, hence it is more suitable to reduce the volume of refuses and make them brittle by heating, and then crush them by using the double-axial crusher. 2 figs.

  12. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  13. Crushing damage estimation for pavement with lightly cementitious bases

    CSIR Research Space (South Africa)

    De Beer, Morris

    2014-07-01

    Full Text Available . Department of Transport. Pretoria, South Africa. Litwinowicz and De Beer., 2013. Long term crushing performance of lightly cementitious pavement materials – update to the South African procedures. Road Materials and Pavement Design. Maina, J.W., De... Beer, M. and van Rensburg, Y., 2013. Modelling Tyre-Road Contact Stresses in Pavement Design and Analysis. Proceedings of 32nd Southern Africa transport conference, Pretoria, July 2013. pp 336-345: SAPDM, (2014). http://www.sapdm.co.za/, last...

  14. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  15. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  16. Amplification-free liquid biopsy by fluorescence approach

    DEFF Research Database (Denmark)

    Uhd, Jesper; Okholm, Anders; Kjems, Jargen

    2017-01-01

    Liquid biopsy is an attractive new paradigm of modern cancer research and clinical oncology. Synergy of fluorescence microscopy with mutation specific molecular probes is a method that we developed for the detection of tumor related circulating DNA, ctDNA. The present detection methods of ctDNA...... samples include amplification-based techniques that have multiple challenges, are often time consuming and rather expensive. In this work, we successfully applied the hybridization assay and advanced microscopy for the reliable amplification-free detection and quantification of cancer associated mutations...... in ctDNA....

  17. Regenerative Potential of D-δ-Tocotrienol Rich Fraction on Crushed Skeletal Muscle of Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Bijo Elsy

    2017-06-01

    Full Text Available Background: Delayed muscle growth and regeneration of skeletal muscle in diabetics is believed to be due to diabetic myopathy because of alteration in the skeletal muscle homeostatis. Since vitamin E is a natural antioxidant and is also important for the integrity of sarcolemma, the present study was designed to explore the muscle regenerative potency of d-δ-tocotrienol-rich fraction (d-δ-TRF on crushed skeletal muscle in healthy and diabetic rats. Materials and Methods: Diabetes was induced through single subcutaneous injection of alloxan (100 mg/kg. Twenty-four albino rats were divided into four groups; healthy control, diabetic control, healthy treated, and diabetic treated. Treated groups received injections orally, daily (200 mg/kg for 3 weeks. A horizontal skin incision was made on the shaved right mid-thigh region, by splitting the fascia between gluteus maximus and tensor fascia lata, and gluteus maximus was crushed with Kocher’s forceps. Skin wound was closed with an absorbable suture. The crushed muscle changes were studied by assessing the histopathological features, histomorphological measurements, and biochemical analyses on 3rd week following induction of injury. One-way “ANOVA” followed by Tukey’s test and Student t-test were used for statistical analysis of data. Results: Results obtained through various methods indicate that the d-δ-TRF treated groups have controlled glycemic status, improved antioxidant capacity, faster revascularization, re-innervation, regeneration of myofibers, and connective tissue remodeling. Conclusion: It is, therefore, concluded that the d-δ-TRF is a beneficial nutritional adjuvant for skeletal muscles’ structural and functional recovery after crushed injury in both healthy and diabetics. [J Interdiscip Histopathol 2017; 5(2.000: 36-42

  18. Evaluation of using crushed brick as coarse aggregate in concrete layer within rigid highway pavement

    Directory of Open Access Journals (Sweden)

    Alwash Ali

    2018-01-01

    Full Text Available Most of the present studies related to the field of highway pavement construction technique tend to make use of the local available materials as substitutes for the imported and necessary materials for some of the practical application. For this reason this research aims at looking for the prospect of used locally available aggregate such as crushed clay bricks for the aim of producing proper concrete with suitable thermal and mechanical properties. Experimental investigations have been carried out to asses the effect of partial replacement of coarse aggregate by free manually crushed Brick with percentages (10, 20, 30 and 40% of virgin coarse aggregate in concrete mix for highway rigid pavement. While the percentage (0% replacement represent reference mix. Mix proportion based on the target of compressive strength for all replacement percentage of (33 MPa at (28 days to achieve AASHTO requirement for highway concrete rigid pavement .The results of flexural strength, modulus of elasticity, density and thermal conductivity refers to better performance (less thickness of concrete layer with large spacing between contraction or expansion joints and less stresses due to warping induced concrete layer for concrete mix with 20% crushed brick as replacement of coarse aggregate.

  19. Abdominal fat pad excisional biopsy for the diagnosis and typing of systemic amyloidosis.

    Science.gov (United States)

    Garcia, Yessica; Collins, A Bernard; Stone, James R

    2018-02-01

    In the past, the diagnosis and typing of amyloidosis often required an invasive biopsy of an internal organ, such as the heart or kidneys. Abdominal fat pad excisional biopsy (FPEB) offers a less invasive approach, but the sensitivity of this technique has been unclear. To determine the sensitivity of FPEB for immunoglobulin light chain (AL) and transthyretin (ATTR) amyloidosis, we performed a retrospective clinicopathologic analysis of 97 patients who had undergone FPEB, of which 16 were positive for amyloid. The most significant pretest feature predicting a positive FPEB was a serum free light chain κ/λ ratio less than .5, and in this group of patients the probability of a positive biopsy was dependent on the size of the biopsy (P=.004). In FPEBs, the amyloid was present in multiple distinct patterns: pericellular, septal, medium-sized vessel, small vessel, and nodular. For patients with AL amyloidosis for which direct typing was attempted using the FPEB tissue, the amyloid was successfully typed in the FPEB in 90% of cases. The overall sensitivity of FPEB was 79% for AL amyloidosis and 12% for ATTR amyloidosis (P=.0003). In patients with AL amyloidosis, the sensitivity of FPEB was dependent on biopsy size, with small biopsies (≤700 mm 3 ) having a sensitivity of ~50%, and large biopsies (>700 mm 3 ) having a sensitivity of ~100%. This study demonstrates that FPEB has high sensitivity for AL amyloidosis, and can be routinely used to type the amyloid. However, FPEB has low sensitivity for ATTR amyloidosis in our patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies.

    Science.gov (United States)

    Mairinger, Fabian D; Walter, Robert Fh; Vollbrecht, Claudia; Hager, Thomas; Worm, Karl; Ting, Saskia; Wohlschläger, Jeremias; Zarogoulidis, Paul; Zarogoulidis, Konstantinos; Schmid, Kurt W

    2014-01-01

    Isothermal multiple displacement amplification (IMDA) can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. A total of 250 μg DNA (concentration 5 μg/μL) was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA.

  1. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  2. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  3. Cement Type Influence on Alkali-Silica Reaction in Concrete with Crushed Gravel Aggregate

    Science.gov (United States)

    Rutkauskas, A.; Nagrockienė, D.; Skripkiūnas, G.

    2017-10-01

    Alkali-silica reaction is one of the chemical reactions which have a significant influence for durability of concrete. During alkali and silica reaction, silicon located in aggregates of the concrete, reacts with high alkali content. This way in the micropores of concrete is forming hygroscopic gel, which at wet environment, expanding and slowly but strongly destroying concrete structures. The goal of this paper- to determine the influence of cement type on alkali-silica reaction of mortars with crushed gravel. In the study crushed gravel with fraction 4/16 mm was used and four types of cements tested: CEM I 42.5 R; CEM I 42.5 SR; CEM II/A-S 42.5; CEM II/A-V 52.5. This study showed that crushed gravel is low contaminated on reactive particles containing of amorphous silica dioxide. The expansion after 14 days exceed 0.054 %, by RILEM AAR-2 research methodology (testing specimen dimension 40×40×160 mm). Continuing the investigation to 56 days for all specimens occurred alkaline corrosion features: microcracking and the surface plaque of gel. The results showed that the best resistance to alkaline corrosion after 14 days was obtained with cement CEM I 42.5 SR containing ash additive, and after 56 days with cement CEM II/A-V 52.5 containing low alkali content. The highest expansion after 14 and 56 days was obtained with cement CEM I 42.5 R without active mineral additives.

  4. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  5. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  6. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  7. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  8. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  9. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  10. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  11. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  12. Percutaneous transhepatic cholangiographic forceps biopsy in pathologic diagnosis for obstructive jaundice

    International Nuclear Information System (INIS)

    Han Xinwei; Li Yongdong; Ma Bo; Xing Gusheng; Wu Gang; Gao Xuemei; Ma Nan

    2004-01-01

    Objective: To evaluate the technical feasibility and sensitivity of percutaneous transhepatic cholangiographic forceps biopsy in bile duct diseases. Methods: Between April 2001 and March 2003, 65 consecutive patients (36 men and 29 women; age range 33-88 years, mean 54 years) with obstructive jaundice underwent transluminal forceps biopsy or/and brush during percutaneous transhepatic cholangiography, percutaneous transhepatic cholangiography and drainage, or placement of stents. The technique was performed through an existing percutaneous transhepatic tract. Multiple specimens were obtained after passing the biopsy forceps or brush into a long 8-French sheath, and the specimens were fixed with formalin for pathologic or cytologic diagnosis. Statistical analysis was performed with the χ 2 test or Fisher exact probability, and P 2 =5.919, P=0.015). The cyctologic diagnosis was acquired in 43 of 58 patients with brush biopsy. Pathologic reports included cholangioadenocarcinoma (n=36), cholangiosquam-ocarcinoma (n=1), pancreatic adenocarcinoma (n=1), hepatocellular carcinoma (n=2), metastatic carcinoma (n=2), zoogloea aggregation (n=1), and negative results (n=15). The sensitivity rate of brush biopsy was 74.14%. Sensitivity of brush in the 45 patients with cholangiocarcinoma was higher than in the 11 patients with malignant tumors other than cholangiocarcinoma (82.22% vs 45.45%, χ 2 =4.563, P=0.033). Sensitivity of forceps biopsy in the 65 patients was higher than that of brush in the 58 patients (χ 2 =4.754, P=0.029). Conclusion: Percutaneous transhepatic cholangiobiopsy is a safe and minimal invasive procedure with no pain and low complication that is easy to perform with no addition trauma through a transhepatic biliary drainage tract. It is an effective, economic, accurate, and reliable new approach, which is safe and easy to perform in acquiring the pathologic diagnosis worthy to spread extensively. (authors)

  13. The influence of crushed rock salt particle gradation on compaction

    International Nuclear Information System (INIS)

    Ran, C.; Daemen, J.J.K.

    1994-01-01

    This paper presents results of laboratory compaction testing to determine the influence of particle size, size gradation and moisture-content on compaction of crushed rock salt. Included is a theoretical analysis of the optimum size gradation. The objective is to evaluate the relative densities that can be achieved with tamping techniques. Initial results indicate that compaction increases with maximum particle size and compaction energy, and varies significantly with article size gradation and water content

  14. Effect of moisture content on the flowability of crushed ores

    OpenAIRE

    Cabrejos Francisco

    2017-01-01

    In many mining and industrial processes where large quantities of non-degrading bulk materials such as crushed ores are handled, silos, hoppers, stockpiles and chutes are widely used because they are economical and reliable (if properly designed and operated). However, they are not free of trouble and may experience flow problems such as arching, ratholing, erratic flow, limited storage capacity, limited discharge flow rate, caking, segregation and/or flooding. Moisture content and fine parti...

  15. Vacuum biopsy of the breast. Experience of St-Jan Hospital in Brugge

    International Nuclear Information System (INIS)

    Steyaert, L.; Van Kerkhove, F.; Casselman, J.

    2004-01-01

    Background. Mammotome is a percutaneous biopsy technique with a large needle, assisted by vacuum aspiration. The single insertion technique allows to collect multiple large tissue samples, which gives a more reliable histological result. The technique can be used under stereotactic, MRI or ultrasound guidance. The technique is used under local anesthesia, on an outpatient basis. Conclusions. Altough it is essentially a diagnostic technique, it has a therapeutic potential in some cases. Recently, the technique has been FDA approved for the removal of benign nodular lesions. Worldwide, over 2 million procedures have already been performed. It has the potential to replace surgical open biopsy, with a similar accuracy and at a lower cost, and it is less invasive. (author)

  16. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  17. Representative-Sandwich Model for Mechanical-Crush and Short-Circuit Simulation of Lithium-ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chao; Santhanagopalan, Shriram; Sprague, Michael A.; Pesaran, Ahmad A.

    2015-07-28

    Lithium-ion batteries are currently the state-of-the-art power sources for a variety of applications, from consumer electronic devices to electric-drive vehicles (EDVs). Being an energized component, failure of the battery is an essential concern, which can result in rupture, smoke, fire, or venting. The failure of Lithium-ion batteries can be due to a number of external abusive conditions (impact/crush, overcharge, thermal ramp, etc.) or internal conditions (internal short circuits, excessive heating due to resistance build-up, etc.), of which the mechanical-abuse-induced short circuit is a very practical problem. In order to better understand the behavior of Lithium-ion batteries under mechanical abuse, a coupled modeling methodology encompassing the mechanical, thermal and electrical response has been developed for predicting short circuit under external crush.

  18. Effect of crushed sand on mortar and concrete rheology

    Directory of Open Access Journals (Sweden)

    Cabrera, O. A.

    2011-09-01

    Full Text Available This article describes an experimental study conducted on fresh mortars and concretes made with crushed sand. The aim of this research was to assess the effect of aggregate particle shape and surface texture as well as dust content on mortar and concrete rheology. The experimental programme also addressed the impact of angular grains on chemical admixture performance and concrete bleeding. The findings showed that the use of crushed sand induces rheological behaviour that differs from the behaviour observed in natural sand and that superplasticisers can improve this behaviour considerably.

    En el presente trabajo se plantea un estudio experimental del estado fresco de morteros y hormigones con arenas de machaqueo, orientado a la evaluación de la incidencia de la forma y textura superficial de los granos del árido fino y del contenido de polvo sobre la reología de las mezclas. El programa experimental comprendió el estudio del estado fresco de hormigones con arenas con partículas angulares, la influencia de este tipo de partículas sobre la efectividad de los aditivos químicos y la evaluación de la influencia de las características físicas del árido fino sobre la exudación. Los resultados muestran que el empleo de arenas de machaqueo provoca un comportamiento reológico diferente al de hormigones con arenas naturales, y que el efecto de los aditivos superfluidificantes mejora notablemente este comportamiento.

  19. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  20. Crush performance of redwood for developing design procedures for impact limiters

    International Nuclear Information System (INIS)

    Cramer, S.M.; Hermanson, J.C.; McMurtry, W.M.

    1995-01-01

    Containers for the transportation of hazardous and radioactive materials incorporate redwood in impact limiters. Redwood is an excellent energy absorber, but only the most simplistic information exists on its crush properties. Tbe stress-strain interrelationship for any wood species subject to three-dimensional stresses is largely unknown for any all stress condition and wood behavior at both high strains and high strain-rates is known only in general terms. Both stress-strain and crush failure theories have been developed based only on uniaxial load tests. The anisotropy of wood adds an additional complexity to measuring wood response and developing suitable theories to describe it. A long history of wood utilization in the building industry has led to design procedures and property information related to simple uniaxial loadings that do not inflict damage to the wood. This lack of knowledge may be surprising for a material that has a long history of engineered use, but the result is difficulty in utilizing wood in more sophisticated designs such as impact limiters. This study provides a step toward filling the information gap on wood material response for high performance applications such as impact limiters

  1. Genetic parameters of the piglet mortality traits stillborn, weak at birth, starvation, crushing, and miscellaneous in crossbred pigs

    DEFF Research Database (Denmark)

    Strange, T.; Ask, B.; Nielsen, B.

    2013-01-01

    This study aimed to estimate genetic parameters for the mortality causes stillborn, weak at birth, starvation, crushing, and miscellaneous in crossbred piglets produced by crossbred dams. Data were collected in a single Danish commercial herd from October 2006 to July 2008 and consisted of 34......,194 piglets (2,152 litters), which originated from 195 Danish Duroc sires and 955 crossbreds between Danish Landrace and Danish Yorkshire dams. Of the 34,194 piglets born, 11.5% were stillborn, 4.2% were crushed by the sow, 2.7% died due to starvation, 2.3% were weak at birth, and 2.2% died of miscellaneous...... traits based on the sire component ranged from -0.05 between stillborn and starvation to 0.35 between stillborn and weak at birth whereas genetic correlations based on the dam component ranged from -0.11 between weak at birth and starvation to 0.76 between crushing and starvation. There seemed...

  2. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  3. Performance of PWR buidings in case of airplane crush

    International Nuclear Information System (INIS)

    L'Huby, Y.; Barbe, B.

    1992-02-01

    Safety standards for the French nuclear power plants are defined in RCC-G. For the risk estimation of airplan crush two type of planes are considered: Lear-Jet 23, and Cesna 210. For estimating the resistance to impact shock of the reactor building deformation criteria were established for concrete and steel reinforcement. A practical calculation method is recommended in RCC-G. Results contain data resulting from impact shock dependent on the military plane type and speed. Finite element method was applied as well as simplified method proposed by Comite Europeen du Breton

  4. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  5. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  6. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  7. Radionuclide sorption on crushed and intact granitic rock

    International Nuclear Information System (INIS)

    Eriksen, Tryggve E.; Locklund, Birgitta

    1989-05-01

    The specific surface areas and distribution ratios for sorption of 85 Sr, 137 Cs and 152 Eu were measured for crushed and intact granite rock. The experimental data can be accommodated by a sorption model encompassing sorption on outer and inner surface. It is clearly demonstrated that the time required to obtain reliable Kd-values for the sorption of strongly sorbing radionuclides like 152 Eu is very long due to solution depletion and slow diffusion into the rock. A combination of surface area measurements and batch sorption with small particles may therefore be preferable when studying strongly sorbing nuclides. (authors) (17 figs., 6 tabs.)

  8. The axial crushes behaviour on foam-filled round Jute/Polyester composite tubes

    Science.gov (United States)

    Othman, A.; Ismail, A. E.

    2018-04-01

    The present paper investigates the effect of axial loading compression on jute fibre reinforced polyester composite round tubes. The specimen of composite tube was fabricated by hand lay-up method of 120 mm length with fix 50.8 mm inner diameter to determine the behaviour of energy absorption on number of layers of 450 angle fibre and internally reinforced with and without foam filler material. The foam filler material used in this studies were polyurethane (PU) and polystyrene (PE) with average of 40 and 45 kg/m3 densities on the axial crushing load against displacement relations and on the failure modes. The number of layers of on this study were two; three and four were selected to calculate the crush force efficiency (CFE) and the specific energy absorption (SEA) of the composite tubes. Result indicated that the four layers’ jute/polyester show significant value in term of crushing load compared to 2 and 3 layers higher 60% for 2 layer and 3% compared to 3 layers. It has been found that the specific energy absorption of the jute/polyester tubes with polystyrene foam-filled is found higher respectively 10% to 12% than empty and polyurethane (PU) foam tubes. The increase in the number of layers from two to four increases the mean axial load from 1.01 KN to 3.60 KN for empty jute/polyester and from 2.11 KN to 4.26 KN for the polyurethane (PU) foam-filled jute/polyester tubes as well as for 3.60 KN to 5.58 KN for the polystyrene (PE) foam-filled jute/polyester. The author’s found that the failure of mechanism influence the characteristic of curve load against displacement obtained and conclude that an increasing number of layers and introduce filler material enhance the capability of specific absorbed energy.

  9. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  10. Indirect MR-arthrography in osteochondral autograft and crushed bone graft with a collagen membrane-Correlation with histology

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, F. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)], E-mail: florian.streitparth@charite.de; Schoettle, P.; Schell, H. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Lehmkuhl, L.; Madej, T.; Wieners, G. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Duda, G.N. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Schroeder, R.J. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)

    2009-04-15

    Objective: To analyze the spectrum of findings in indirect MR-arthrography following osteochondral autograft transfer system (OATS) and crushed bone graft using a magnetic resonance imaging (MRI) scoring and grading system in relation to histology as the standard of reference. Materials and methods: Iatrogenic lesions were set at ovine condylar facets (n = 6/group), treated with OATS or crushed bone graft. 1.5 T MRI was performed 6 months after surgery using PD-weighted (w fat saturated (fs) fast spin echo (FSE), T1-w 2D, and 3D fs gradient echo (GE) sequences 30 min. after i.v. Gd-DTPA administration and passive joint exercise. The repair tissue was evaluated by two independent radiologists. The MR findings were compared to histology. Results: In all cases, MRI and histologic grading correlated well and showed significant superior repair in OATS at 6 months (p < 0.05), reproducing the original articular contour and a good subchondral restoration. FsT1-w3DGE proved most appropriate identifying characteristic post-operative findings: the OATS group demonstrated bone marrow edema at the donor site and the graft/host interface showed significant enhancement in indirect MR-arthrography, indicating fibrocartilage. After crushed bone graft, we found an irregular structure and significant contrast uptake, consistent with remnants of bone grafts surrounded by inflammatory tissue. Conclusion: Indirect MR-arthrography is an accurate, non-invasive monitoring tool following OATS and crushed bone graft as the MRI scoring and grading system allows a reliable evaluation of normal and pathological osteochondral repair with a high histologic correlation.

  11. Mix proportioning and performance of a crushed limestone sand-concrete

    OpenAIRE

    Makhloufi Zoubir; Bouziani Tayeb; Bédérina Madani; Hadjoudja Mourad

    2014-01-01

    Satisfying the ever-growing demand of concrete aggregates poses a problem in many parts of the world due to shortage of natural sand. Moreover, to conserve natural resources and protect civil engineering infrastructures, there is a need to find alternative materials. Crushed stone sand has been identified as a potential substitute material for natural sand in making good quality concrete. The main objective of the present investigation is to determine an adequate mix design method and evaluat...

  12. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  13. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  14. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  15. Proposed method of producing large optical mirrors Single-point diamond crushing followed by polishing with a small-area tool

    Science.gov (United States)

    Wright, G.; Bryan, J. B.

    1986-01-01

    Faster production of large optical mirrors may result from combining single-point diamond crushing of the glass with polishing using a small area tool to smooth the surface and remove the damaged layer. Diamond crushing allows a surface contour accurate to 0.5 microns to be generated, and the small area computer-controlled polishing tool allows the surface roughness to be removed without destroying the initial contour. Final contours with an accuracy of 0.04 microns have been achieved.

  16. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  17. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    International Nuclear Information System (INIS)

    Barnett, Joseph; Tavare, Aniket N.; Khan, Sajid; Saini, Ashish; Creer, Dean D.; Hare, Samanjit S.

    2017-01-01

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  18. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Joseph; Tavare, Aniket N. [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Khan, Sajid [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Saini, Ashish [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Creer, Dean D. [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Hare, Samanjit S., E-mail: samhare@nhs.net [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom)

    2017-05-15

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  19. Gallic acid and exercise training improve motor function, nerve conduction velocity but not pain sense reflex after experimental sciatic nerve crush in male rats.

    Science.gov (United States)

    Hajimoradi, Maryam; Fazilati, Mohammad; Gharib-Naseri, Mohammad Kazem; Sarkaki, Alireza

    2015-01-01

    The aim of present study was to evaluate the effects of oral administration of gallic acid (GA) for 21 days alone and in combination with exercise on nerve conduction velocity and sensory and motor functions in rats with sciatic nerve crush. Seventy adult male Wistar rats (250-300 g) were divided randomly into 7 groups with 10 in each: 1) Control (Cont), 2) Crushed + Vehicle (Cr +Veh), 3-5) Crushed + gallic acid (Cr+GA) (50, 100, and 200 mg/kg/2 mL, orally), 6) Crushed + exercise (Cr+Exe), and 7) Crushed + exercise + effective dose of gallic acid (Cr+Exe +GA200) for 21 days. In order to establish an animal model of sciatic nerve crush, equivalent to 7 kg of force pressed on 2-3 mm of sciatic nerve for 30 s, three times with 30 s intervals. Pain sense reflex in hot plate, motor coordination in rotarod, and sciatic nerve conduction velocity (SNCV) in all groups were tested. Data were analyzed using one-way ANOVA followed by Tukey's post hoc test and preflex latency was not changed in treated groups. Motor coordination and SNCV were improved in groups Cr+GA200 and Cr+Exe + GA200 (p<0.05, p<0.01 vs. Cr+Veh). GA, dose-dependently, may have therapeutic potential to improve the peripheral nerve degeneration, which is most likely related, at least in part, to its antioxidant and therapeutic properties.

  20. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  4. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  5. Investigation of the use of waste crushed glass in the production of asphalt mixes

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2017-06-01

    Full Text Available Recent study at the Council for Scientific and Industrial Research in South Africa has revealed the potential to substitute depleting natural aggregates with waste crushed glass in asphalt mixes. This paper presents an investigation of the use...

  6. Review of evaluations of crushing results for the seedbed preparation

    Directory of Open Access Journals (Sweden)

    Siegfried Anisch

    2016-06-01

    Full Text Available For evaluating the work results of tillage operations today only inaccurate parameters are available which cannot be readily measured. Thus, evaluating and comparing the work results of machines and developing suitable sensors are difficult. At the Technical University of Dresden, till 1990, research projects for determining aggregate size composition of soil have been done. Based on this work, this study will show suggestions for measuring, displaying and evaluation of soil crushing results depending on tillage work conditions.

  7. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  8. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  9. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  10. Determination of exposure to respirable quartz in the stone crushing units at Azendarian-West of Iran.

    Science.gov (United States)

    Bahrami, Abdul Rahman; Golbabai, Faridah; Mahjub, Hossien; Qorbani, Farshid; Aliabadi, Mohsan; Barqi, Mohamadali

    2008-08-01

    The purpose of this study is to describe the personal exposure to respirable dust and quartz and in stone crushing units located at west of Iran. A size of 40 personal samples and 40 stationary samples were obtained and analysis was done by X-ray diffraction (XRD). The results of personal sampling were shown the concentrations of respirable dust exposure level in workers of process, hopper and drivers were 1.90, 2.22, 1.41 times greater than Occupational Safety and Health Administration permissible exposure limit (OSHA PEL). The average value of total dust and respirable dust emission from stationary sources was 9.46 mg/m(3), 1.24 mg/m(3) respectively, showing that 13.8 % of total dust is respirable. The efficiency of local exhaust ventilation (LEV) to control of particles inside of industrial units was greater than 99%. It is concluded from this research the particulate generated from stone crushing activities contain a significant amount of respirable particle. The amount of free silica in stone quartz is 85 to 97 percent that emission of particles effect to health workers. LEV has important effect in the removal of silica particles in stone crushing units. The worker of hoppers still exposed to silica more than standard limits.

  11. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  12. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  13. Recycled Asphalt Pavement and Crushed Concrete Backfill: State-of-the-Art Review and Material Characterization

    Science.gov (United States)

    2001-10-01

    This report describes research results from the first year of a three-year study focused on the use of recycled asphalt pavement (RAP) and crushed concrete (CC) as backfill for mechanically stabilized earth (MSE) walls.

  14. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  15. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  16. Clinical Outcome After DK Crush Versus Culotte Stenting of Distal Left Main Bifurcation Lesions: The 3-Year Follow-Up Results of the DKCRUSH-III Study.

    Science.gov (United States)

    Chen, Shao-Liang; Xu, Bo; Han, Ya-Ling; Sheiban, Imad; Zhang, Jun-Jie; Ye, Fei; Kwan, Tak W; Paiboon, Chitprapai; Zhou, Yu-Jie; Lv, Shu-Zheng; Dangas, George D; Xu, Ya-Wei; Wen, Shang-Yu; Hong, Lang; Zhang, Rui-Yan; Wang, Hai-Chang; Jiang, Tie-Ming; Wang, Yan; Sansoto, Teguh; Chen, Fang; Yuan, Zu-Yi; Li, Wei-Min; Leon, Martin B

    2015-08-24

    The present study aimed to investigate the difference in major adverse cardiac events (MACE) at 3 years after double-kissing (DK) crush versus culotte stenting for unprotected left main distal bifurcation lesions (LMDBLs). The multicenter and randomized DKCRUSH-III (Comparison of double kissing crush versus culotte stenting for unprotected distal left main bifurcation lesions: results from a multicenter, randomized, prospective study) showed that DK crush stenting was associated with fewer MACE at 1-year follow-up in patients with LMDBLs compared with culotte stenting. Here, we report the 3-year clinical outcome of the DKCRUSH-III study. A total of 419 patients with LMDBLs who were randomly assigned to either the DK crush or culotte group in the DKCRUSH-III study were followed for 3 year. The primary endpoint was the occurrence of a MACE at 3 years. Stent thrombosis (ST) was the safety endpoint. Patients were classified by simple and complex LMDBLs according to the DEFINITION (Definition and Impact of Complex Bifurcation Lesions on Clinical Outcomes After Percutaneous Coronary Intervention Using Drug-Eluting Stents) study criteria. At 3 years, MACE occurred in 49 patients the culotte group and in 17 patients in the DK crush group (cumulative event rates of 23.7% and 8.2%, respectively; p DK crush group (p = 0.007). Complex LMDBLs were associated with a higher rate of MACE (35.3%) at 3 years compared with a rate of 8.1% in patients with simple LMDBLs (p DK] Crush Versus Culotte Stenting for the Treatment of Unprotected Distal Left Main Bifurcation Lesions: DKCRUSH-III, a Multicenter Randomized Study Comparing Double-Stent Techniques; ChiCTR-TRC-11001877). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Optimal combinations for detection of prostate cancer: systematic sextant and laterally directed biopsies versus systematic sextant and color Doppler-targeted biopsies.

    Science.gov (United States)

    Kravchick, Sergey; Cytron, Shmuel; Peled, Ronit; London, Daniel; Sibi, Yosef; Ben-Dor, David

    2004-02-01

    To determine the accuracy of different combinations of biopsies in detecting prostate cancer. The standard sextant protocol for obtaining prostate biopsy underestimates the presence of prostate cancer. Conversely, an increased cancer detection rate has been obtained with additional laterally directed biopsies. The results of the studies dedicated to transrectal color Doppler (CD) sonography have shown that it might detect neoplastic lesions with no corresponding gray-scale abnormality. A total of 120 consecutive patients underwent sextant biopsy with additional biopsy cores taken from the lateral peripheral zone (four to six cores, depending on the prostate volume) and CD-guided biopsy. The sensitivity of laterally directed, CD-guided, and different combinations of biopsies was compared. Various patient, clinical, and pathologic factors were compared, and multivariate analysis was performed to assess the strongest predictor of cancer detection. Cancer was detected in 43 (35.8%) of 120 patients. The combination of sextant biopsy with laterally directed cores gained sensitivity to 56.6% compared with 67.4% obtained in the regimen that combined sextant and CD-guided biopsy. The CD regimen detected cancer in 11 additional patients. However, the differences in the detection rates of these combinations were not statistically significant (P = 0.797). The results of multivariate analysis showed that sextant biopsy and laterally directed cores were the strongest predictors of cancer detection (odds ratio 8.356 versus 49.282; 95% confidence interval 1.698 to 41.114 versus 10.508 to 231.130). The regimen that included sextant and CD-guided biopsy was the most sensitive. However, only standard sextant and laterally directed biopsies were statistically significant predictors of cancer detection on biopsy.

  18. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  19. Effects of insulin-like growth factor-I and platelet-rich plasma on sciatic nerve crush injury in a rat model.

    Science.gov (United States)

    Emel, Erhan; Ergün, Selma Sönmez; Kotan, Dilcan; Gürsoy, Esra Başar; Parman, Yeşim; Zengin, Asli; Nurten, Asiye

    2011-02-01

    Local administration of insulin-like growth factor-I (IGF-I) has been shown to increase the rate of axon regeneration in crush-injured and freeze-injured rat sciatic nerves. Local administration of platelet-rich plasma (PRP) has been also shown to have a measurable effect on facial nerve regeneration after transection in a rat model. The objective of the study was to compare the effects of locally administered IGF-I and PRP on the parameters of the Sciatic Function Index (SFI), sensory function (SF), axon count, and myelin thickness/axon diameter ratio (G-ratio) in a rat model of crush-injured sciatic nerves. The right sciatic nerve of Wistar albino rats (24 animals) was crushed using a Yasargil-Phynox aneurysm clip for 45 minutes. All animals were randomly divided into 3 groups: Group 1 (control group) was treated with saline, Group 2 was treated with IGF-I, and Group 3 was treated with PRP. Injections were performed using the tissue expander's injection port with a connecting tube directed at the crush-injured site. Functional recovery was assessed with improvement in the SFI. Recovery of sensory function was using the pinch test. Histopathological examination was performed 3 months after the injury. The SFI showed an improved functional recovery in the IGF-I-treated animals (Group 2) compared with the saline-treated animals (Group 1) 30 days after the injury. In IGF-I-treated rats, sensory function returned to the baseline level significantly faster than in saline-treated and PRP-treated rats as shown in values between SF-2 and SF-7. The G-ratios were found to be significantly higher in both experimental groups than in the control group. This study suggests that the application of IGF-I to the crush-injured site may expedite the functional recovery of paralyzed muscle by increasing the rate of axon regeneration.

  20. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  1. Effect of shape and surface texture of aggregates during high intensity vertical shaft impact autogeneous crushing

    International Nuclear Information System (INIS)

    Samayamutthirian Palaniandy; Khairun Azizi Mohd Azizli

    2002-01-01

    The demand for quarry industry to produce high quality aggregates is increasing parallel with the demand of high strength concrete. Focus on the high quality aggregates production is very essential as 70% of the concrete consist of aggregates. High quality aggregate is characterised according to its shape, surface texture and its size distribution. The cubical and more equidimensional aggregates are characterised as high quality aggregates. Besides photomicrograph of aggregates, Flakiness and Elongation indices are important empirical measurements to determine the quality of the aggregates. The Barmac Rock On Rock Vertical Shaft Impactor proved that the shape of the aggregates can be improved by various crushing mechanisms as the EI and FI values were low and 75% of the cubical particles were observed in the crushed aggregates. (Author)

  2. Characterisation of extra virgin olive oils from Galician autochthonous varieties and their co-crushings with Arbequina and Picual cv.

    Science.gov (United States)

    Reboredo-Rodríguez, P; González-Barreiro, C; Cancho-Grande, B; Fregapane, G; Salvador, M D; Simal-Gándara, J

    2015-06-01

    The current trend of the olive oil market is the production of high quality extra from traditional minor olive varieties with peculiar and differentiated characteristics (especially with respect to the aromatic and phenolic composition). In this way, the interest of Galician oil producers (NW Spain) in recovering old autochthonous Local olive fruits has increased substantially in recent years. In order to investigate the potential of the Local olives by either producing high quality monovarietal oils or mixing with the most widespread olives in Galicia (Arbequina and Picual cv.), quality indices, and fatty acid composition as well as volatile and phenolic profiles were determined and compared. All EVOOs studied in this work can be considered as "extra virgin olive oil" due to quality indices fell within the ranges established in legislation. Picual and Local olive oils as well as those resulting from their co-crushing reach values which are required by EU legislation to add the specific health claim on the oil label. Co-crushing Picual:Local (80:20) provided a significant enhancement of grass and apple nuances and a decrease of banana notes with respect to Picual oils. The co-crushing process improved sensory and health properties of Picual extra virgin olive oils. The effect of co-crushing on phenolics, ester volatiles and banana nuances cannot be easily modulated, contrary to quality indices and fatty acid composition, both changing linearly in strict correlation with the fruit mass ratio. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  4. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  5. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  6. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  7. Robot-assisted biopsies in a high-field MRI system. First clinical results

    International Nuclear Information System (INIS)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S.; Czerny, C.

    2012-01-01

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  8. The production of pig iron from crushing plant waste using hot blast cupola

    Directory of Open Access Journals (Sweden)

    Kusno Isnugroho

    2018-03-01

    Full Text Available A production of pig iron has been conducted from crushing plant waste. The process of preparing pig iron was using hot blast cupola (HBC furnace which was injected with charcoal powder to improve temperature process and reduction zone in the furnace. The process was started by washing process and magnetic separation of raw material as an effort to improve iron content degree from crushing plant waste. The next process was preparing the composite pellet with the particle size of −80 + 100 mesh and with the composition of 80% iron ore, 15% wood charcoal, and 5% bentonite. The result of pellet size was 2.5–4.0 mm. The experiment was continued to reduce pellet composite in the HBC furnace. The pig iron produced from this process contained of 93.62%Fe, 3.5%C, 1.55%Si, 0.87%Mn, 0.05%P, and 0.087%S.With this result, the pig iron produced already fulfill the metallurgical specification to be used in smelting industry. Keywords: Pig iron, Pellet, Injection, Charcoal, Hot blast cupola

  9. Volume reduction and plutonium recovery in alpha wastes by cryogenic crushing and lixiviation

    International Nuclear Information System (INIS)

    Arnal, T.; Pajot, J.

    1986-06-01

    The industry of plutonium generates solid alpha wastes of medium activity called ''technological wastes''. They are mainly produced during the fabrication and reprocessing of nuclear reactor fuels and they are of a wide variety i.e: vinyl bags, gloves, glass, steel materials used in glove box operation, etc... These wastes contain relevant residual quantities of uranium and plutonium in the form of oxides or nitrates, reaching up to several dozen grams per cubic meter. Up to the beginning of the eighties, they were conditionned without any treatment and stored as such on the production site. However, for an economic and safe storage, recovering of the plutonium contained in these waste streams and reduction of their volume is of obvious importance. At the plutonium ''Complexe de Fabrication des Combustibles de Cadarache'' was developed a new technical solution of this problem that combines cryogenic crushing of the solid waste and plutonium recovery from the crushed material by chemical lixiviation. The first results obtained in applying this system on the industrial scale are reported briefly

  10. Clay modified crushed salt for shaft sealing elements. Material optimization and evaluation in field tests

    Energy Technology Data Exchange (ETDEWEB)

    Glaubach, Uwe; Hofmann, Martin; Gruner, Matthias; Kudla, Wolfram [TU Bergakademie Freiberg (Germany). Inst. of Mining and Special Civil Engineering

    2015-07-01

    Salt-based materials are intended to use for backfill and sealing systems in geotechnical barriers in underground HLW-repositories. Due to the creep of the saliniferous host rock, the salt backfill will be compacted during several hundreds or thousands years of operation to a minimum of porosity resp. permeability. To raise the sealing potential of a salt-based backfill, the porosity after construction should be minimized by optimal material performance and compaction performance. A procedure to optimize the grain size distribution of crushed salt and its water and clay content is described. The optimized salt fraction gets a better compaction behavior than straight mine-run salt. The addition of a filler-like material (e.g. Friedland Clay Powder) reduces the total porosity and permeability. Backfill columns made from crushed salt and clay probably include an instant sealing function.

  11. Hypophosphatemic osteomalacia: an unusual clinical presentation of multiple myeloma.

    Science.gov (United States)

    Reyskens, M; Sleurs, K; Verresen, L; Janssen, M; van den Bergh, J; van den Berg, J; Geusens, P

    2015-07-01

    An unusual case of a 75-year-old man is presented who had multiple stress fractures due to adult onset hypophosphatemic osteomalacia, which was the result of Fanconi syndrome, with light chain cast proximal tubulopathy due to multiple myeloma. A 75-year-old man presented with diffuse pain and muscle weakness. He had multiple stress fractures, low serum phosphate, decreased renal tubular reabsorption of phosphate, and normal PTH and FGF23, indicating adult onset hypophosphatemic osteomalacia. Phosphate supplements with calcitriol resulted in clinical recovery and healing of stress fractures. Because of proteinuria, a renal biopsy was performed that revealed Fanconi syndrome with light chain cast proximal tubulopathy and light kappa chains were found in serum and urine. A bone biopsy confirmed the diagnosis of multiple myeloma, and treatment with chemotherapy resulted in cytological and clinical recovery.

  12. Evaluation of the Effects of Crushed and Expanded Waste Glass Aggregates on the Material Properties of Lightweight Concrete Using Image-Based Approaches.

    Science.gov (United States)

    Chung, Sang-Yeop; Abd Elrahman, Mohamed; Sikora, Pawel; Rucinska, Teresa; Horszczaruk, Elzbieta; Stephan, Dietmar

    2017-11-25

    Recently, the recycling of waste glass has become a worldwide issue in the reduction of waste and energy consumption. Waste glass can be utilized in construction materials, and understanding its effects on material properties is crucial in developing advanced materials. In this study, recycled crushed and expanded glasses are used as lightweight aggregates for concrete, and their relation to the material characteristics and properties is investigated using several approaches. Lightweight concrete specimens containing only crushed and expanded waste glass as fine aggregates are produced, and their pore and structural characteristics are examined using image-based methods, such as scanning electron microscopy (SEM), X-ray computed tomography (CT), and automated image analysis (RapidAir). The thermal properties of the materials are measured using both Hot Disk and ISOMET devices to enhance measurement accuracy. Mechanical properties are also evaluated, and the correlation between material characteristics and properties is evaluated. As a control group, a concrete specimen with natural fine sand is prepared, and its characteristics are compared with those of the specimens containing crushed and expanded waste glass aggregates. The obtained results support the usability of crushed and expanded waste glass aggregates as alternative lightweight aggregates.

  13. Evaluation of the Effects of Crushed and Expanded Waste Glass Aggregates on the Material Properties of Lightweight Concrete Using Image-Based Approaches

    Directory of Open Access Journals (Sweden)

    Sang-Yeop Chung

    2017-11-01

    Full Text Available Recently, the recycling of waste glass has become a worldwide issue in the reduction of waste and energy consumption. Waste glass can be utilized in construction materials, and understanding its effects on material properties is crucial in developing advanced materials. In this study, recycled crushed and expanded glasses are used as lightweight aggregates for concrete, and their relation to the material characteristics and properties is investigated using several approaches. Lightweight concrete specimens containing only crushed and expanded waste glass as fine aggregates are produced, and their pore and structural characteristics are examined using image-based methods, such as scanning electron microscopy (SEM, X-ray computed tomography (CT, and automated image analysis (RapidAir. The thermal properties of the materials are measured using both Hot Disk and ISOMET devices to enhance measurement accuracy. Mechanical properties are also evaluated, and the correlation between material characteristics and properties is evaluated. As a control group, a concrete specimen with natural fine sand is prepared, and its characteristics are compared with those of the specimens containing crushed and expanded waste glass aggregates. The obtained results support the usability of crushed and expanded waste glass aggregates as alternative lightweight aggregates.

  14. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Impact of crushed mineral aggregate on the pumpability of concrete during transport and placement

    Directory of Open Access Journals (Sweden)

    Topličić-Ćurčić Gordana

    2016-01-01

    Full Text Available In the spirit of the sustainable buildings, and with the goal of protection of river courses, in the near future an already announced directive ordering closing down of a large number of river aggregate dredging operations will be adopted. For that reason, usage of crushed mineral aggregate in concrete mixes is increasing. Irrespective of downsides of the fined crushed mineral aggregate, such as the presence of fine particles bordering the upper permissible limit and the unfavorable shape of the grain of the course aggregate for obtaining liquid consistency required for the pumpable concrete, the demanded pumpability of concrete during transport and placement has been achieved. By adding admixtures to concrete, the required concrete properties, such as: frost resistance, simultaneous frost and salt resistance and water tightness have been achieved. [Projekat Ministarstva nauke Republike Srbije, br. TR 36017: Utilization of by - products and recycled waste materials in concrete composites in the scope of sustainable construction development in Serbia: investigation and environmental assessment of possible applications

  16. IMPACT OF ROCK HARDNESS ON FRAGMENTATION BY HYDRAULIC HAMMER AND CRUSHING IN JAW CRUSHER

    Directory of Open Access Journals (Sweden)

    Trpimir Kujundžić

    2008-12-01

    Full Text Available The physical and mechanical characteristics of intact rocks depend on the way of their formation, sustained deformations and the process of wearing a specific rock has been exposed to. These characteristics have a rather high influence on the technological process of extraction and dressing of mineral raw materials. However, the mechanical characteristics of rocks due to use of explosives for their extraction in the open pit have a more significant impact. The rock blocks extracted by blasting which are larger than the opening of the primary crusher are usually fragmented by hydraulic hammer. The paper presents the results of the testing of impact of rock hardness on fragmentation of rocks by means of hydraulic hammer and during crushing in jaw crusher. The testing was carried out on the rock samples from five quarries. According to the obtained results the hardness has a considerably larger impact on the fragmentation energy by hydraulic hammer than on the crushing energy in jaw crusher.

  17. Evaluation of steel slag and crushed limestone mixtures as subbase material in flexible pavement

    Directory of Open Access Journals (Sweden)

    Ahmed Ebrahim Abu El-Maaty Behiry

    2013-03-01

    Full Text Available Steel slag is produced as a by-product during the oxidation of steel pellets in an electric arc furnace. This by-product that mainly consists of calcium carbonate is broken down to smaller sizes to be used as aggregates in pavement layers. They are particularly useful in areas where a good-quality aggregate is scarce. This research study was conducted to evaluate the effect of quantity of steel slag on the mechanical properties of blended mixes with crushed limestone aggregates, which used as subbase material in Egypt. Moreover, a theoretical analysis was employed to estimate the resistance for failure factors such as vertical deformations, vertical and radial stresses and vertical strains of subbase under overweight trucks loads. These loads cause severe deterioration to the pavement and thus reduce its life. The results indicated that the mechanical characteristics, and the resistance factors were improved by adding steel slag to the crushed limestone.

  18. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  19. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  20. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  1. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  2. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  3. Whole and crushed nutlets of chia (Salvia hispanica from Mexico as a source of functional gums

    Directory of Open Access Journals (Sweden)

    Maira Segura-Campos

    2014-12-01

    Full Text Available The objective of this study was to characterize the chemical and functional properties of Mexican chia (Salvia hispanica gums extracted from defatted whole and crushed nutlets using the Soxhlet and SFE-CO2 methods. Chia gums have interesting chemical and functional properties for the food industry. The oil and gum yields were in the range of 1.98-16.42% and 5.81-12.60%, respectively. The defatting procedure did not affect significantly the oil and gum extraction; the nutlet type (whole or crushed was the only parameter influencing the yield. The proximate composition and the protein and fiber contents of chia gum were evaluated. Low contents of protein and fiber and high NFE levels were found in whole nutlet gums. The functional properties of chia gum extracted from whole and crushed nutlets with the Soxhlet and SFE-COs methods showed the following ranges of water absorption capacity of 62.64 to 143.66 g/g, water adsorption capacity of 0.69 to 1.35 g/g, and water and oil holding capacity of 100 to 149.28 g/g and19.5 to 40.4 g/g, respectively. The rheological behavior exhibited by the gums was pseudoplastic or shear thinning. From a functional perspective, chia gum is an important food component due its emulsifier and stabilizer potentials.

  4. Digital quantification of gene expression in sequential breast cancer biopsies reveals activation of an immune response.

    Directory of Open Access Journals (Sweden)

    Rinath M Jeselsohn

    Full Text Available Advancements in molecular biology have unveiled multiple breast cancer promoting pathways and potential therapeutic targets. Large randomized clinical trials remain the ultimate means of validating therapeutic efficacy, but they require large cohorts of patients and are lengthy and costly. A useful approach is to conduct a window of opportunity study in which patients are exposed to a drug pre-surgically during the interval between the core needle biopsy and the definitive surgery. These are non-therapeutic studies and the end point is not clinical or pathological response but rather evaluation of molecular changes in the tumor specimens that can predict response. However, since the end points of the non-therapeutic studies are biologic, it is critical to first define the biologic changes that occur in the absence of treatment. In this study, we compared the molecular profiles of breast cancer tumors at the time of the diagnostic biopsy versus the definitive surgery in the absence of any intervention using the Nanostring nCounter platform. We found that while the majority of the transcripts did not vary between the two biopsies, there was evidence of activation of immune related genes in response to the first biopsy and further investigations of the immune changes after a biopsy in early breast cancer seem warranted.

  5. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    OpenAIRE

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-01-01

    Purpose: To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. Methods: We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assist...

  6. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  7. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  8. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  9. Full-thickness rectal biopsy in children suspicious for Hirschsprung's disease is safe and yields a low number of insufficient biopsies

    DEFF Research Database (Denmark)

    Bjørn, Niels; Rasmussen, Lars; Qvist, Niels

    2018-01-01

    INTRODUCTION: The diagnosis of Hirschsprung's disease (HD) relies on the histological demonstration of aganglionosis in the bowel wall. Biopsies may be obtained by rectal suction biopsy (RSB) or by transanal full-thickness excision biopsy (FTB). The objective of the present study was to evaluate...... the frequency of complications and inconclusive biopsies after FTB in children referred with suspicion of HD. The secondary objective was to calculate the frequency of proven aganglionosis. METHODS: A retrospective chart review was performed of all patients under the age of 16years who underwent transanal FTB...... during the time period of 2008-2014. RESULTS: A total of 555 patients were included in the review. Inconclusive biopsies were found at the primary biopsy in 35 patients (5.9%). Aganglionosis was found in 12% of the cases. The complication rate was 6.6% (39 patients), 85% of which were classified...

  10. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  11. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  12. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  13. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  14. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  15. Activation of α7 nicotinic acetylcholine receptor decreases on-site mortality in crush syndrome through insulin signaling-Na/K-ATPase pathway

    Directory of Open Access Journals (Sweden)

    Bo-Shi eFan

    2016-03-01

    Full Text Available On-site mortality in crush syndrome remains high due to lack of effective drugs based on definite diagnosis. Anisodamine is widely used in China for treatment of shock, and activation of α7 nicotinic acetylcholine receptor (α7nAChR mediates such antishock effect. The present work was designed to test whether activation of α7nAChR with anisodamine decreased mortality in crush syndrome shortly after decompression. Sprague-Dawley rats and C57BL/6 mice with crush syndrome were injected with anisodamine (20 mg/kg and 28 mg/kg respectively, i.p. 30 min before decompression. Survival time, serum potassium, insulin, and glucose levels were observed shortly after decompression. Involvement of α7nAChR was verified with methyllycaconitine (selective α7nAChR antagonist and PNU282987 (selective α7nAChR agonist, or in α7nAChR knockout mice. Effect of anisodamine was also appraised in C2C12 myotubes. Anisodamine reduced mortality and serum potassium and enhanced insulin sensitivity shortly after decompression in animals with crush syndrome, and PNU282987 exerted similar effects. Such effects were counteracted by methyllycaconitine or in α7nAChR knockout mice. Mortality and serum potassium in rats with hyperkalemia were also reduced by anisodamine. Phosphorylation of Na/K-ATPase was enhanced by anisodamine in C2C12 myotubes. Inhibition of tyrosine kinase on insulin receptor, phosphoinositide 3-kinase, mammalian target of rapamycin, signal transducer and activator of transcription 3, and Na/K-ATPase counteracted the effect of anisodamine on extracellular potassium. These findings demonstrated that activation of α7nAChR could decrease on-site mortality in crush syndrome, at least in part based on the decline of serum potassium through insulin signaling-Na/K-ATPase pathway.

  16. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  17. Widespread high grade prostatic intraepithelial neoplasia on biopsy predicts the risk of prostate cancer: A 12 months analysis after three consecutive prostate biopsies

    Directory of Open Access Journals (Sweden)

    Cosimo De Nunzio

    2013-06-01

    Full Text Available Purpose: To evaluate the risk of prostate cancer (PCa on a third prostate biopsy in a group of patients with two consecutive diagnoses of high grade intraepithelial neoplasia (HGPIN. Materials and methods: From November 2004 to December 2007, patients referred to our clinic with a PSA ! 4 ng/ml or an abnormal digital rectal examination (DRE were scheduled for trans-rectal ultrasound (TRUS guided 12-core prostate biopsy. Patients with HGPIN underwent a second prostate biopsy, and if the results of such procedure yielded a second diagnosis of HGPIN, we proposed a third 12-core needle biopsy regardless of PSA value. Crude and adjusted logistic regressions were used to assess predictors of PCa on the third biopsy. Results: A total of 650 patients underwent 12 cores transrectal ultrasound prostatic biopsy in the study period. Of 147 (22% men with a diagnosis of HGPIN, 117 underwent a second prostatic biopsy after six months and 43 a third biopsy after other six months. After the third biopsy, 19 patients (34% still showed HGPIN, 15 (35% were diagnosed with PCa and 9 (21% presented with chronic prostatitis. Widespread HGPIN on a second biopsy was significantly associated with PCa on further biopsy (!2 = 4.04, p = 0.04. Moreover, the presence of widespread HGPIN significantly predicted the risk of PCa on crude and adjusted logistic regressions. Conclusions: Widespread HGPIN on second biopsy is associated with the presence of PCa on a third biopsy. Nonetheless, the relationship between HGPIN and PCa remains complex and further studies are needed to confirm our findings.

  18. The crush and spray: a patented design for herbicide application with less waste

    Science.gov (United States)

    Cherie LeBlanc Fisher; Adam H. Wiese

    2009-01-01

    The USDA Forest Service recently patented an equipment design to deliver herbicides more efficiently and cost-effectively. Towed by a standard all-terrain vehicle, the Crush and Spray can access out-of-the-way or wet locations. An adjustable roller first knocks down the unwanted plants. A low-set spray boom with wide angle sprayer nozzles then provides precise, close-...

  19. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  20. Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, K.; Kornecki, A.; Bax, J.; Mundt, Y.; Fenster, A. [Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Radiology, St. Joseph' s Health Care London, London, Ontario N6A 4V2 (Canada) and Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 5A5 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Radiology, St. Joseph' s Health Care London, London, Ontario N6A 4V2 (Canada) and Department of Diagnostic Radiology and Nuclear Medicine, University of Western Ontario, London, Ontario N6A 5A5 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada); Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada) and Department of Medical Imaging, University of Western Ontario, London, Ontario N6A 5A5 (Canada)

    2009-06-15

    Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample

  1. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  2. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  3. Sentinel lymph node mapping and biopsy in breast cancer - facts and unanswered questions; Waechterlymphknotendetektion und -Biopsie beim Mammakarzinom - Fakten und unbeantwortete Fragen

    Energy Technology Data Exchange (ETDEWEB)

    Czech, N. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Schleswig-Holstein, Campus Kiel (Germany)

    2006-06-15

    The concept of sentinel lymph node (SLN) biopsy in breast cancer patients is rapidly becoming the standard of care [1]. The fast assent of this technique in clinical practise is the result of multiple factors, including accuracy of the technique, decreased morbidity, and supplying the pathologist with only few nodes which allows a more focused and sensitive histopathologic evaluation. The sentinel nodes are those most likely to contain tumour cells that have spread from the tumour. Histopathological evaluation of these nodes therefore can be an accurate predictor for metastases in the respective lymph node basin and can guide regional and systemic treatment. The SLN-biopsy concerns the identification and subsequent resection of the initial lymph nodes (SLN) which are draining the primary tumour. These nodes can be identified by radioguided lymphatic mapping and/or by visualisation of the nodes with vital blue dyes. Axillary lymph node dissection (ALND) and its morbidity can be avoided in patients with negative SLN. Despite the success and acceptance of lymphatic mapping, some controversies and questions remain unanswered. In this review, some of the most relevant clinical issues will be discussed. (orig.)

  4. Laboratory investigation of crushed salt consolidation and fracture healing

    International Nuclear Information System (INIS)

    1987-01-01

    A laboratory test program was conducted to investigate the consolidation behavior of crushed salt and fracture healing in natural and artificial salt. Crushed salt is proposed for use as backfill in a nuclear waste repository in salt. Artificial block salt is proposed for use in sealing a repository. Four consolidation tests were conducted in a hydrostatic pressure vessel at a maximum pressure of 2500 psi (17.2 MPa) and at room temperature. Three 1-month tests were conducted on salt obtained from the Waste Isolation Pilot Plant and one 2-month test was conducted on salt from Avery Island. Permeability was obtained using argon and either a steady-state or transient method. Initial porosities ranged from 0.26 to 0.36 and initial permeabilities from 2000 to 50,000 md. Final porosities and permeabilities ranged from 0.05 to 0.19 and from -5 md to 110 md, respectively. The lowest final porosity (0.05) and permeability ( -5 md) were obtained in a 1-month test in which 2.3% moisture was added to the salt at the beginning of the test. The consolidation rate was much more rapid than in any of the dry salt tests. The fracture healing program included 20 permeability tests conducted on fractured and unfractured samples. The tests were conducted in a Hoek cell at hydrostatic pressures up to 3000 psi (20.6 MPa) with durations up to 8 days. For the natural rock salt tested, permeability was strongly dependent on confining pressure and time. The effect of confining pressure was much weaker in the artificial salt. In most cases the combined effects of time and pressure were to reduce the permeability of fractured samples to the same order of magnitude (or less) as the permeability measured prior to fracturing

  5. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies; Perkutane stereotaktische Biopsie nicht palpabler Mammalaesionen mit dem Advanced Breast Biopsy Instrumentation (ABBI) System: kritische Evaluation der Indikationsstellung

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G. [Basel Univ. (Switzerland). Inst. fuer Diagnostische Radiologie; Oertli, D. [Basel Univ. (Switzerland). Inst. fuer Chirurgie; Torhorst, J. [Basel Univ. (Switzerland). Inst. fuer Pathologie

    2001-03-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [German] Ziel: Perkutane stereotaktische Biopsien mit dem ABBI stellen eine neue Alternative in der Abklaerung nicht palpabler Mammalaesionen dar. Es soll die Indikationsstellung mit und ohne Anwendung des Breast Imaging Reporting and Data System (BI-RADS) analysiert werden. Material und Methoden: Insgesamt wurde bei 62 Patientinnen mit 64 Laesionen eine Biopsie mit dem ABBI System durchgefuehrt. Die primaere Indikation zur ABBI Biopsie wurde von Nicht-Radiologen aufgrund von Mikrokalzifikationen in 53 Faellen und einer unklaren Verdichtung in 11 Faellen gestellt. Zusaetzlich erfolgte eine retrospektive Indikationsstellung der biopsierten

  6. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  7. Direct 40Ar/39Ar age determination of fluid inclusions using in-vacuo¬ stepwise crushing - Example of garnet from the Cycladic Blueschist Unit on Syros

    Science.gov (United States)

    Uunk, Bertram; Postma, Onno; Wijbrans, Jan; Brouwer, Fraukje

    2017-04-01

    Metamorphic minerals and veins commonly trap attending hydrous fluids in fluid inclusions, which yield a wealth of information on the history of the hosting metamorphic system. When these fluids are sufficiently saline, the KCl in the inclusions can be used as a K/Ar geochronologic system, potentially dating inclusion incorporation. Whilst primary fluid inclusions (PFIs) can date fluid incorporation during mineral or vein growth, secondary fluid inclusion trails (SFIs) can provide age constraints on later fluid flow events. At VU Amsterdam, a new in-vacuo crushing apparatus has been designed to extract fluid inclusions from minerals for 40Ar/39Ar analysis. Separates are crushed inside a crusher tube connected to a purification line and a quadrupole mass spectrometer. In-vacuo crushing is achieved by lifting and dropping a steel pestle using an externally controlled magnetic field. As the gas can be analyzed between different crushing steps, the setup permits stepwise crushing experiments. Additionally, crushed powder can be heated by inserting the crusher tube in an externally controlled furnace. Dating by 40Ar/39Ar stepwise crushing has the added advantage that, during neutron irradiation to produce 39Ar from 39K, 38Ar and 37Ar are also produced from 38Cl and 40Ca, respectively. Simultaneous analysis of these argon isotopes permits constraining the chemistry of the argon source sampled during the experiment. This allows a distinction between different fluid or crystal lattice sources. Garnet from three samples of the HP metamorphic Cycladic Blueschist Unit on Syros, Greece was stepwise crushed to obtain fluid inclusion ages. Initial steps for all three experiments yield significant components of excess argon, which are interpreted to originate from grain boundary fluids and secondary fluid inclusions trails. During subsequent steps, age results stabilize to a plateau age. One garnet from North Syros yields an unusually old 80 Ma plateau age. However, isochrons

  8. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  9. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  10. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  11. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  12. Contraindications of sentinel lymph node biopsy: Áre there any really?

    Directory of Open Access Journals (Sweden)

    Zografos George

    2007-01-01

    Full Text Available Abstract Background One of the most exciting and talked about new surgical techniques in breast cancer surgery is the sentinel lymph node biopsy. It is an alternative procedure to standard axillary lymph node dissection, which makes possible less invasive surgery and side effects for patients with early breast cancer that wouldn't benefit further from axillary lymph node clearance. Sentinel lymph node biopsy helps to accurately evaluate the status of the axilla and the extent of disease, but also determines appropriate adjuvant treatment and long-term follow-up. However, like all surgical procedures, the sentinel lymph node biopsy is not appropriate for each and every patient. Methods In this article we review the absolute and relative contraindications of the procedure in respect to clinically positive axilla, neoadjuvant therapy, tumor size, multicentric and multifocal disease, in situ carcinoma, pregnancy, age, body-mass index, allergies to dye and/or radio colloid and prior breast and/or axillary surgery. Results Certain conditions involving host factors and tumor biologic characteristics may have a negative impact on the success rate and accuracy of the procedure. The overall fraction of patients unsuitable or with multiple risk factors that may compromise the success of the sentinel lymph node biopsy, is very small. Nevertheless, these patients need to be successfully identified, appropriately advised and cautioned, and so do the surgeons that perform the procedure. Conclusion When performed by an experienced multi-disciplinary team, the SLNB is a highly effective and accurate alternative to standard level I and II axillary clearance in the vast majority of patients with early breast cancer.

  13. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  14. Study of the fracture behavior of mortar and concretes with crushed rock or pebble aggregates

    Directory of Open Access Journals (Sweden)

    Sebastião Ribeiro

    2011-03-01

    Full Text Available The objective of this work was to compare the fracture energy of mortar and concretes produced with crushed rock and pebble aggregates using zero, 10, 20, 30 and 40% of aggregates mixed with standard mortar and applying the wedge splitting method to achieve stable crack propagation. The samples were cast in a special mold and cured for 28 days, after which they were subjected to crack propagation tests by the wedge splitting method to determine the fracture energies of the mortar and concrete. The concretes showed higher fracture energy than the mortar, and the concretes containing crushed rock showed higher resistance to crack propagation than all the compositions containing pebbles. The fracture energy varied from 38 to 55 J.m-2. A comparison of the number of aggregates that separated from the two concrete matrices with the highest fracture energies indicated that the concrete containing pebbles crumbled more easily and was therefore less resistant to crack propagation.

  15. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  16. Coupling of Mechanical Behavior of Lithium Ion Cells to Electrochemical-Thermal Models for Battery Crush; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad; Zhang, Chao; Santhanagopalan, Shriram; Sahraei, Elham; Wierzbiki, Tom

    2015-06-15

    Propagation of failure in lithium-ion batteries during field events or under abuse is a strong function of the mechanical response of the different components in the battery. Whereas thermal and electrochemical models that capture the abuse response of batteries have been developed and matured over the years, the interaction between the mechanical behavior and the thermal response of these batteries is not very well understood. With support from the Department of Energy, NREL has made progress in coupling mechanical, thermal, and electrochemical lithium-ion models to predict the initiation and propagation of short circuits under external crush in a cell. The challenge with a cell crush simulation is to estimate the magnitude and location of the short. To address this, the model includes an explicit representation of each individual component such as the active material, current collector, separator, etc., and predicts their mechanical deformation under different crush scenarios. Initial results show reasonable agreement with experiments. In this presentation, the versatility of the approach for use with different design factors, cell formats and chemistries is explored using examples.

  17. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  18. Dominant inheritance of retinal ganglion cell resistance to optic nerve crush in mice

    Directory of Open Access Journals (Sweden)

    Schlamp Cassandra L

    2007-03-01

    Full Text Available Abstract Background Several neurodegenerative diseases are influenced by complex genetics that affect an individual's susceptibility, disease severity, and rate of progression. One such disease is glaucoma, a chronic neurodegenerative condition of the eye that targets and stimulates apoptosis of CNS neurons called retinal ganglion cells. Since ganglion cell death is intrinsic, it is reasonable that the genes that control this process may contribute to the complex genetics that affect ganglion cell susceptibility to disease. To determine if genetic background influences susceptibility to optic nerve damage, leading to ganglion cell death, we performed optic nerve crush on 15 different inbred lines of mice and measured ganglion cell loss. Resistant and susceptible strains were used in a reciprocal breeding strategy to examine the inheritance pattern of the resistance phenotype. Because earlier studies had implicated Bax as a susceptibility allele for ganglion cell death in the chronic neurodegenerative disease glaucoma, we conducted allelic segregation analysis and mRNA quantification to assess this gene as a candidate for the cell death phenotype. Results Inbred lines showed varying levels of susceptibility to optic nerve crush. DBA/2J mice were most resistant and BALB/cByJ mice were most susceptible. F1 mice from these lines inherited the DBA/2J phenotype, while N2 backcross mice exhibited the BALB/cByJ phenotype. F2 mice exhibited an intermediate phenotype. A Wright Formula calculation suggested as few as 2 dominant loci were linked to the resistance phenotype, which was corroborated by a Punnett Square analysis of the distribution of the mean phenotype in each cross. The levels of latent Bax mRNA were the same in both lines, and Bax alleles did not segregate with phenotype in N2 and F2 mice. Conclusion Inbred mice show different levels of resistance to optic nerve crush. The resistance phenotype is heritable in a dominant fashion involving

  19. Fugitive emissions control on dry copper tailing with crushed rock armor

    International Nuclear Information System (INIS)

    Haase, E.F.

    1992-01-01

    Four inactive copper tailing impoundments totalling 1,900 acres near Ajo in southwestern Arizona were covered on horizontal surfaces with a 2 in. nominal thickness of crushed rock to control particulate emissions. The tailings are typically dominated by sand-sized particles but may also include significant PM 10 fractions towards the centers of the impoundments. The technology was selected by Phelps Dodge Corporation, after investigation of several alternatives, as a permanent and practical cover that essentially eliminates fugitive emissions. It simulates the natural desert pavement that characterizes this arid area of the Sonoran Desert. Rocky overburden was crushed to minus 3 in. diameter and broadcast on dry surfaces of tailing impoundments with all-terrain, balloon-tired spreaders. Stony residues in the rock armor tend to cement together following rainfall, forming a crust that enhances surface stability and erosion control. Slopes with windblown tailing deposition were covered to a nominal 6 in. thickness by conventional dozer pushing and blading of minus 10 in. rock over the sides. Athel trees, planted extensively since 1970 on two of the four inactive impoundments, provided partial control of fugitives, but were subjected to harsh environmental conditions, including abrasion from saltating particles. The rock armor functions as a mulch which is expected to improve water relations for existing vegetation and areas seeded with native species. New surface microenvironments, and the virtual elimination of surface creep and saltation, are expected to support native plant growth under favorable climatic conditions

  20. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  1. Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy?

    Science.gov (United States)

    Chin, Jun L.; Pavlides, Michael; Moolla, Ahmad; Ryan, John D.

    2016-01-01

    Liver fibrosis reflects sustained liver injury often from multiple, simultaneous factors. Whilst the presence of mild fibrosis on biopsy can be a reassuring finding, the identification of advanced fibrosis is critical to the management of patients with chronic liver disease. This necessity has lead to a reliance on liver biopsy which itself is an imperfect test and poorly accepted by patients. The development of robust tools to non-invasively assess liver fibrosis has dramatically enhanced clinical decision making in patients with chronic liver disease, allowing a rapid and informed judgment of disease stage and prognosis. Should a liver biopsy be required, the appropriateness is clearer and the diagnostic yield is greater with the use of these adjuncts. While a number of non-invasive liver fibrosis markers are now used in routine practice, a steady stream of innovative approaches exists. With improvement in the reliability, reproducibility and feasibility of these markers, their potential role in disease management is increasing. Moreover, their adoption into clinical trials as outcome measures reflects their validity and dynamic nature. This review will summarize and appraise the current and novel non-invasive markers of liver fibrosis, both blood and imaging based, and look at their prospective application in everyday clinical care. PMID:27378924

  2. Sam68 promotes Schwann cell proliferation by enhancing the PI3K/Akt pathway and acts on regeneration after sciatic nerve crush

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Weijie, E-mail: 459586768@qq.com; Liu, Yuxi, E-mail: 924013616@qq.com; Wang, Youhua, E-mail: wyouhua1516@163.com

    2016-05-13

    Sam68 (Src-associated in mitosis of 68 kD), a KH domain RNA-binding protein, is not only important in signaling transduction cascades, but crucial in a variety of cellular processes. Sam68 is reported to be involved in the phospoinositide3-kinase (PI3K) and nuclear factor-kappa B (NF-κB) signaling pathways, and it is closely associated with cell proliferation, RNA metabolism, and tumor progression. However, we know little about the role of Sam68 during peripheral nervous system injury and regeneration. In this study, we investigated the expression of Sam68 and its biological significances in sciatic nerve crush. Interestingly, we found Sam68 had a co-localization with S100 (Schwann cell marker). Moreover, after crush, Sam68 had a spatiotemporal protein expression, which was in parallel with proliferation cell nuclear antigen (PCNA). In vitro, we also observed increased expression of Sam68 during the process of TNF-α-induced Schwann cell proliferation model. Besides, flow cytometry analyses, CCK-8, and EDU were all performed with the purpose of investigating the role of Sam68 in the regulation of Schwann cell proliferation. Even more importantly, we discovered that Sam68 could enhance the phosphorylation of Akt while LY294002 (a PI3K inhibitor) obviously reversed Sam68-induced cell proliferation. Finally, we detected the variance during regeneration progress through the rat walk footprint test. In summary, all these evidences demonstrated that Sam68 might participate in Schwann cell proliferation partially via PI3K/Akt pathway and also regulate regeneration after sciatic nerve crush. -- Highlights: •The dynamic changes and location of Sam68 after sciatic nerve crush. •Sam68 promoted Schwann cell proliferation via PI3K/Akt pathway. •Sam68 modulated functional recovery after sciatic nerve crush.

  3. Sam68 promotes Schwann cell proliferation by enhancing the PI3K/Akt pathway and acts on regeneration after sciatic nerve crush

    International Nuclear Information System (INIS)

    Wu, Weijie; Liu, Yuxi; Wang, Youhua

    2016-01-01

    Sam68 (Src-associated in mitosis of 68 kD), a KH domain RNA-binding protein, is not only important in signaling transduction cascades, but crucial in a variety of cellular processes. Sam68 is reported to be involved in the phospoinositide3-kinase (PI3K) and nuclear factor-kappa B (NF-κB) signaling pathways, and it is closely associated with cell proliferation, RNA metabolism, and tumor progression. However, we know little about the role of Sam68 during peripheral nervous system injury and regeneration. In this study, we investigated the expression of Sam68 and its biological significances in sciatic nerve crush. Interestingly, we found Sam68 had a co-localization with S100 (Schwann cell marker). Moreover, after crush, Sam68 had a spatiotemporal protein expression, which was in parallel with proliferation cell nuclear antigen (PCNA). In vitro, we also observed increased expression of Sam68 during the process of TNF-α-induced Schwann cell proliferation model. Besides, flow cytometry analyses, CCK-8, and EDU were all performed with the purpose of investigating the role of Sam68 in the regulation of Schwann cell proliferation. Even more importantly, we discovered that Sam68 could enhance the phosphorylation of Akt while LY294002 (a PI3K inhibitor) obviously reversed Sam68-induced cell proliferation. Finally, we detected the variance during regeneration progress through the rat walk footprint test. In summary, all these evidences demonstrated that Sam68 might participate in Schwann cell proliferation partially via PI3K/Akt pathway and also regulate regeneration after sciatic nerve crush. -- Highlights: •The dynamic changes and location of Sam68 after sciatic nerve crush. •Sam68 promoted Schwann cell proliferation via PI3K/Akt pathway. •Sam68 modulated functional recovery after sciatic nerve crush.

  4. Nerve crush but not displacement-induced stretch of the intra-arachnoidal facial nerve promotes facial palsy after cerebellopontine angle surgery.

    Science.gov (United States)

    Bendella, Habib; Brackmann, Derald E; Goldbrunner, Roland; Angelov, Doychin N

    2016-10-01

    Little is known about the reasons for occurrence of facial nerve palsy after removal of cerebellopontine angle tumors. Since the intra-arachnoidal portion of the facial nerve is considered to be so vulnerable that even the slightest tension or pinch may result in ruptured axons, we tested whether a graded stretch or controlled crush would affect the postoperative motor performance of the facial (vibrissal) muscle in rats. Thirty Wistar rats, divided into five groups (one with intact controls and four with facial nerve lesions), were used. Under inhalation anesthesia, the occipital squama was opened, the cerebellum gently retracted to the left, and the intra-arachnoidal segment of the right facial nerve exposed. A mechanical displacement of the brainstem with 1 or 3 mm toward the midline or an electromagnet-controlled crush of the facial nerve with a tweezers at a closure velocity of 50 and 100 mm/s was applied. On the next day, whisking motor performance was determined by video-based motion analysis. Even the larger (with 3 mm) mechanical displacement of the brainstem had no harmful effect: The amplitude of the vibrissal whisks was in the normal range of 50°-60°. On the other hand, even the light nerve crush (50 mm/s) injured the facial nerve and resulted in paralyzed vibrissal muscles (amplitude of 10°-15°). We conclude that, contrary to the generally acknowledged assumptions, it is the nerve crush but not the displacement-induced stretching of the intra-arachnoidal facial trunk that promotes facial palsy after cerebellopontine angle surgery in rats.

  5. EXPERIMENTAL RESEARCH OF PROCESSING OF DUMP SAND-CLAY MIXES BY THE CENTRIFUGAL AND SHOCK CRUSHING

    Directory of Open Access Journals (Sweden)

    V. V. Vorobev

    2015-01-01

    Full Text Available Results of experimental research of processing of centrifugal and shock crushing of dump sandy-clay mixes are given. Use of products of processing of received mixes in foundry production and in production of asphalt concrete mixes allows to exclude transportation of the mix to dumping.

  6. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  7. Discrepancies between biopsy-based and excision-based grading of cervical intraepithelial neoplasia: the important role of time between excision and biopsy.

    Science.gov (United States)

    Zhang, Lu; Li, Qiang; Zhao, Mingyu; Jia, Lin; Zhang, Youzhong

    2015-05-01

    We sought to evaluate the rate of cervical intraepithelial neoplasia (CIN) ≤ 1 in loop electrosurgical excision procedure (LEEP) specimens after the treatment of biopsy-proven CIN 2-3, and to identify factors that are associated with the rate of CIN ≤ 1, especially focusing on the time interval between biopsy and LEEP. The goal of this research is to reduce the overtreatment of women with CIN 2-3. This was a retrospective study performed on women undergoing LEEP for biopsy-proven CIN 2-3 in Qilu hospital in Shandong, China. Patients were separated according to LEEP pathology (CIN ≤ 1 vs. CIN 2-3), and compared using the χ2 test and Student t test. The main outcome measures were pathologic discrepancy (defined as CIN 2-3 at biopsy, but CIN ≤ 1 at excision). Of the 391 women with biopsy-proven CIN 2-3, 26.9% had LEEP specimens with CIN ≤ 1 histologies. The likelihood of a CIN ≤ 1 LEEP specimen increases for greater biopsy-LEEP intervals (odds ratio, 1.374; 95% confidence interval, 1.089-1.735; P = 0.008). Cases in younger women and biopsy-assessed CIN 2 cases were both more likely to have CIN 1 or negative LEEP specimens. The rate of spontaneous histologic regression (defined as CIN ≤ 1 at resection) was 26.9%. These low-grade lesions were more common in LEEP specimens from young women with CIN 2 at biopsy, and who underwent LEEP later after the initial biopsy.

  8. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  9. Discrete element modeling of cemented sand and particle crushing at high pressures

    OpenAIRE

    de Bono, John Patrick

    2013-01-01

    This project aims to provide an insight into the behaviour of cemented sand under high pressures, and to further the understanding of the role of particle crushing. The discrete element method is used to investigate the micro mechanics of sand and cemented sand in high-pressure triaxial tests and one-dimensional normal compression. Using the software PFC3D, a new triaxial model has been developed, which features an effective flexible membrane that allows free deformation of the specimen ...

  10. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  11. Comments on US approach to backfilling: Thermochemical characterization of crushed salt

    International Nuclear Information System (INIS)

    Smith, S.; Hume, H.

    1988-01-01

    From recent studies and calculations, it has become apparent that expected brine in a United States salt repository would not seriously detract from the usefulness of rock salt as backfill. It also has been shown that adding clay to the salt might add to the pressure on the emplaced waste packages. Nevertheless, the Salt Repository Project has planned to evaluate a betonite/salt mixture during the next few years. The following items have also been discussed: advantages of backfilling, variables affecting crushed salt behavior, and the general approach to a preliminary testing program

  12. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  13. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  14. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  15. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  16. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  17. Temporal artery biopsies in south-east Scotland: a five year review.

    Science.gov (United States)

    Gajree, S; Borooah, S; Dhillon, N; Goudie, C; Smith, C; Aspinall, P; Dhillon, B

    2017-06-01

    Temporal artery biopsy is the gold standard investigation for the diagnosis of giant cell arteritis. The aim of this retrospective study was to investigate the use of temporal artery biopsy in diagnosing giant cell arteritis in south-east Scotland over a five-year period. We aimed to quantify success rates, and predictive factors for a positive biopsy, as well as compare the different specialities performing the biopsies. The data should enable the development of better criteria for referral for investigation of giant cell arteritis. Methods Patients were identified using a database of temporal artery biopsies generated by the pathology department in NHS Lothian (south east Scotland), for all biopsies examined between January 2010 and December 2015. An electronic patient record was used to retrospectively examine the records of patients in the database. Results A total of 715 biopsies were included in the study, of which 250 (35.0%) showed features of giant cell arteritis. The main predictors for a positive biopsy were age at biopsy, specialty performing biopsy, erythrocyte sedimentation rate, jaw claudication/pain, and ophthalmic symptoms. The most important predictor of a positive biopsy was erythrocyte sedimentation rate. The length of biopsy was not found to be a predictor of positive biopsy; however, diameter of biopsy was predictive. Conclusions We have shown that many temporal artery biopsies are negative, and finding ways to reduce the number of patients unnecessarily undergoing biopsy will be essential in reducing workload and streamlining services. This study demonstrates some key predictive factors for patients with positive biopsies. The study also shows that a large proportion of biopsies taking place do not result in the recommended length of specimen, but this does not necessarily reduce the likelihood of a positive biopsy.

  18. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  19. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  20. Trends of Serum Electrolyte Changes in Crush syndrome patients of Bam Earthquake; a Cross sectional Study

    Directory of Open Access Journals (Sweden)

    Saeed Safari

    2016-12-01

    Full Text Available Introduction: Electrolyte imbalances are very common among crushed earthquake victims but there is notenough data regarding their trend of changes. The present study was designed to evaluate the trend of changesin sodium, calcium, and phosphorus ions among crush syndrome patients. Methods: In this retrospectivecross-sectional study, using the database of Bam earthquake victims, which was developed by Iranian Society ofNephrology following Bam earthquake, Iran, 2003, the 10-day trend of sodium, calcium, and phosphorus ionschanges in > 15 years old crush syndrome patients was evaluated. Results: 118 patients with the mean age of25.6 § 6.9 yearswere studied (57.3 male. On the first day of admission, 52.5% (95% CI: 42.7 - 62.3 of the patientshad hyponatremia, which reached 43.9% (95% CI: 28.5 - 59.3 on day 10. 100.0% of patients were hypocalcemicon admission and serum calcium level did not change dramatically during the 10 days of hospitalization. Theprevalence of hyperphosphatemia on the first day was 90.5% (95% CI: 81.5 - 99.5 and on the 10th day of hospitalization66.7% (95% CI: 48.5 - 84.8 of the patients were still affected. Conclusion: The results of the presentstudy shows the 52.5%prevalence of hyponatremia, 100% hypocalcemia, and 90.5% hyperphosphatemia amongcrush syndrome patients of Bam earthquake victims on the first day of admission. Evaluation of 10-day trendshows a slow decreasing pattern of these imbalances as after 10 days, 43.9% still remain hyponatremic, 92.3%hypocalcemic, and 66.7% hypophosphatemic.

  1. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  2. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    Science.gov (United States)

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary

  3. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Sea Dredged Gravel versus Crushed Granite as Coarse Aggregate for Self Compacting Concrete in Aggressive Environment

    DEFF Research Database (Denmark)

    Sørensen, Eigil V.; Kristensen, Lasse Frølich

    2007-01-01

    Properties of self compacting concrete (SCC) with two types of coarse aggregate - sea dredged gravel with smooth and rounded particles and crushed granite with rough and angular particles - have been studied. Sea gravel allowed a higher aggregate proportion in the concrete leading to a higher...

  5. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  6. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  7. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  8. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    Science.gov (United States)

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  9. Concrete crushing and sampling, a methodology and technology for the unconditional release of concrete material from decommissioning

    International Nuclear Information System (INIS)

    Gills, R.; Lewandowski, P.; Ooms, B.; Reusen, N.; Van Laer, W.; Walthery, R.

    2007-01-01

    Belgoprocess started the industrial decommissioning of the main process building of the former Eurochemic reprocessing plant in 1990, after completion of a pilot project. Two small storage buildings for final products from reprocessing were dismantled to verify the assumptions made in a previous paper study on decommissioning, to demonstrate and develop dismantling techniques and to train personnel. Both buildings were emptied and decontaminated to background levels. They were demolished and the remaining concrete debris was disposed of as industrial waste and green field conditions restored. Currently, the decommissioning operations carried out at the main building have made substantial progress. They are executed on an industrial scale. In view of the final demolition of the building, foreseen to start in the middle of 2008, a clearance methodology for the concrete from the cells into the Eurochemic building has been developed. It considers at least one complete measurement of all concrete structures and the removal of all detected residual radionuclides. This monitoring sequence is followed by a controlled demolition of the concrete structures and crushing of the resulting concrete parts to smaller particles. During the crushing operations, metal parts are separated from the concrete and representative concrete samples are taken. The frequency of sampling meets the prevailing standards. In a further step, the concrete samples are milled, homogenised, and a smaller fraction is sent to the laboratory for analyses. The paper describes the developed concrete crushing and sampling methodology. (authors)

  10. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  11. Migration of Gelfoam to the gallbladder after liver biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Chris [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada); Dalhousie University, School of Medicine, Halifax (Canada); Ahmed, Bilal [University of Toronto School of Medicine, Toronto (Canada); Doyle, John [The Hospital for Sick Children, Department of Hematology/Oncology, Toronto (Canada); Connolly, Bairbre L. [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada)

    2008-07-15

    Liver biopsy is a common procedure, with an inherent risk of bleeding. There are different ways to help avoid hemorrhage, including biopsy through a transjugular venous route or embolization of the tract with liquid or solid materials. We describe an image-guided percutaneous core needle liver biopsy with tract embolization using thick Gelfoam slurry in a pediatric oncology patient. Imaging studies acquired after the biopsy indicated that the Gelfoam mixture had likely migrated to the gallbladder and common bile duct. We report this rare occurrence with its striking imaging in order to make those performing biopsies aware of this possibility. (orig.)

  12. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  13. Use of a novel percutaneous biopsy localization device: initial musculoskeletal experience

    International Nuclear Information System (INIS)

    Roberts, C.C.; Morrison, W.B.; Deely, D.M.; Zoga, A.C.; Koulouris, G.; Winalski, C.S.

    2007-01-01

    To preliminarily evaluate a new CT-biopsy guidance device, the SeeStar (Radi, Uppsala, Sweden), for use in musculoskeletal applications. The device was evaluated using an imaging phantom and in various simulated clinical biopsy situations. The phantom study was undertaken to optimize the linear metallic artifacts produced by the guidance device. The phantom and guidance device were imaged with CT after altering different imaging parameters, including field of view, filter, focal spot size, kV, mAs, slice thickness and pitch. Clinical biopsy situations were simulated for a superficial biopsy, a deep biopsy and a horizontal biopsy approach. Altering CT parameters had little effect on the subjective appearance of the linear metal artifact, which is used to plan the biopsy approach. Placement of an 18-G needle inside of the biopsy device was subjectively helpful in exaggerating the artifact. Use of this artifact could be helpful in planning biopsy approach for deep lesions or lesions near critical structures. The metal guide on the device adequately supports a standard biopsy needle, making it potentially advantageous for biopsy of superficial lesions and lesions approached from a horizontal orientation. Use of this CT-biopsy guidance device is potentially useful for musculoskeletal applications. The linear metal artifact produced by the device can help plan the biopsy approach. The device can also be useful in biopsy situations where the biopsy needle requires external support during imaging. (orig.)

  14. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  15. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  16. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  17. Sorption and desorption reactions of radionuclides with a crushed basalt-bentonite packing material

    International Nuclear Information System (INIS)

    Barney, G.S.; Lane, D.L.; Allen, C.C.; Jones, T.E.

    1985-04-01

    Current design of waste packages for disposal of high-level radioactive wastes in underground basalt formations includes a layer of packing material that surrounds the waste container. One of the functions of this material is to limit the release of radionuclides from a breached container into groundwater by providing a low hydraulic conductivity zone and by sorbing dissolved radionuclides. The objective of this study was to assess the radionuclide sorption capability of a proposed packing material composed of 25% sodium bentonite and 75% crushed basalt (by weight). Sorption and desorption reactions of several important waste radioelements (neptunium, uranium, plutonium, technetium, selenium, and radium) were investigated in the absence of air at 90 0 C. Uranium and neptunium were sorbed by slow reactions that follow first-order kinetics. The reaction rates are probably controlled by reduction of weakly sorbed uranium(VI) and neptunium(V) by ferrous iron in the crushed basalt component. Technetium(VII) was not reduced or sorbed under these conditions. Freundlich sorption and desorption isotherms for a given radionuclide were non-singular and show a strong tendency for sorption hysteresis. Applying the isotherm data to a one-dimensional transport model indicated that hysteretic sorption on the packing material provides an important safety factor in controlling releases of some radionuclides

  18. The effect of weight-bearing exercise and non-weight-bearing exercise on gait in rats with sciatic nerve crush injury.

    Science.gov (United States)

    Kim, Ki-Hyun; Hwangbo, Gak; Kim, Seong-Gil

    2015-04-01

    [Purpose] The purpose of this study was to access the effect of weight bearing exercise (treadmill exercise) and non-weight-bearing exercise (swimming exercise) on gait in the recovery process after a sciatic nerve crush injury. [Subjects and Methods] Rats were randomly divided into a swimming group (n=3) with non-weight-bearing exercise after a sciatic nerve crush and a treadmill group (n=3) with weight bearing exercise after a sciatic nerve crush. Dartfish is a program that can analyze and interpret motion through video images. The knee lateral epicondyle, lateral malleolus, and metatarsophalangeal joint of the fifth toe were marked by black dots before recording. [Results] There were significant differences in TOK (knee angle toe off) and ICK (knee angle at initial contact) in the swimming group and in TOK, ICA (ankle angle at initial contact), and ICK in the treadmill group. In comparison between groups, there were significant differences in TOA (ankle angle in toe off) and ICA at the 7th day. [Conclusion] There was no difference between weight bearing and non-weight-bearing exercise in sciatic nerve damage, and both exercises accelerated the recovery process in this study.

  19. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  20. Application of vacuum metallurgy to separate pure metal from mixed metallic particles of crushed waste printed circuit board scraps.

    Science.gov (United States)

    Zhan, Lu; Xu, Zhenming

    2008-10-15

    The principle of separating pure metal from mixed metallic particles (MMPs) byvacuum metallurgy is that the vapor pressures of various metals at the same temperature are different As a result, the metal with high vapor pressure and low boiling point can be separated from the mixed metals through distillation or sublimation, and then it can be recycled through condensation under a certain condition. The vacuum metallurgy separation (VMS) of MMPs of crushed waste printed circuit boards (WPCBs) has been studied in this paper. Theoretical analyses show that the MMPs (copper, zinc, bismuth, lead, and indium, for example) can be separated by vacuum metallurgy. The copper particles (0.15-0.20 mm) and zinc particles (<0.30 mm) were chosen to simulate the MMPs of crushed WPCBs. Experimental results show that the separated efficiency of zinc in the copper-rich particles achieves 96.19 wt % when the vacuum pressure is 0.01-0.10 Pa, the heating temperature is 1123 K, and the heating time is 105 min. Under this operation condition, the separated efficiency of zinc in the copper-rich particles from crushed WPCBs achieves 97.00 wt % and the copper purity increases from 90.68 to 99.84 wt %.

  1. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  2. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  3. Role of Water Sorption in Tablet Crushing Strength, Disintegration, and Dissolution.

    Science.gov (United States)

    Sacchetti, M; Teerakapibal, R; Kim, K; Elder, E J

    2017-08-01

    Drugs formulated as tablets are subjected to accelerated stability conditions with the goal of identifying a stable formulation that will exhibit a sufficiently long shelf life. Water sorption at a condition such as 40°C/75% RH can result in significant changes in tablet properties such as a decrease in dissolution rate, the cause of which may be difficult to interpret, given the complex nature of ingredients and their interactions in a tablet. In this research, three drugs, displaying a wide range of physicochemical properties, were formulated with commonly used diluents, disintegrants, and binders, using a design of experiments approach. The tablets were stored at accelerated conditions and assessed for content, dissolution, disintegration, and crushing strength, as well as other properties. The research demonstrated many water-induced effects in tablet properties. Due to the experimental design approach that revealed many interactions, it was possible to interpret all of the changes observed in tablet crushing strength, disintegration, and dissolution for the drugs using a common set of physical principles. Specifically, the relevant factors considered were (1) mechanical properties of materials, (2) water sorption surface effects in surface diffusion and capillary condensation, (3) water sorption bulk effects for amorphous materials such as viscous flow/spreading, and (4) water-induced stress on interparticle bonding arising from volume expansion. These physical principles enable a comprehensive interpretation of the complex changes observed in tablet properties, which should be valuable in the design of tablet formulations that will be stable to accelerated storage conditions.

  4. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  5. The criteria for the decision of transrectal US-guided prostate biopsy: Can we reduce the number of unnecessary biopsies?

    International Nuclear Information System (INIS)

    Cho, Joon Hyung; Cho, Jae Ho; Ahn, Jay Hong; Chang, Jay Chun

    2001-01-01

    To establish the criteria which can safely reduce the number of unnecessary biopsies by comparing the transrectal ultrasonography (TRUS) findings, serum prostate-specific antigen (PSA), and prostate specific antigen density (PSAD) in the decision of criteria for the prostatic biopsy using TRUS. Two hundred and twenty patients underwent TRUS- guided prostate biopsy due to elevated PSA and/or focal nodule on TRUS were included. Sixty five (27.5%) patients were confirmed as prostate cancer, and remained 155 (70.5%) patients were reported as benign diseases including benign prostate hyperplasia. The sensitivity, specificity and accuracy of TRUS, PSA and PSAD were evaluated and the single criterion or the combination of the criteria which can safely reduce the unnecessary biopsies without missing prostatic cancer were investigated. The sensitivity, specificity and accuracy of TRUS, PSA (cut-off value, 4 ng/ml) and PSAD (cut-off level, 0.2 ng/ml/cm 3 ) were 78.5%/95.4%/95.4%/27.8%/51.6%/64/5%, 42.7%/64.5%/73.6%, respectively. PSAD cut-off level 0.2 ng/ml/cm 3 was the most excellent single criterion for the decision of prostatic biopsy and the number of unnecessary biopsies was 100 cases. But 3 cases of prostatic cancer which the PSAD level was below 0.2 ng/ml/cm 3 were included and in all these 3 cases, a focal nodule was detected on TRUS. Therefore, we applied these two criteria at once and the biopsies of 30 cases (13.6%) are unnecessary. With the single criterion, we could not obtain the satisfactory results but by the combinations of criteria (TRUS and PSAD), 30 (13.6%) cases are unnecessary biopsies without missing cancer. We think that the short term follow-up may be a substitute for the immediate when nodular lesion is suspicious on TRUS and serum PSAD level is below 0.2 ng/ml/cm 3 .

  6. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  7. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  8. Numerical Investigation on Dynamic Crushing Behavior of Auxetic Honeycombs with Various Cell-Wall Angles

    Directory of Open Access Journals (Sweden)

    Xin-chun Zhang

    2015-02-01

    Full Text Available Auxetic honeycombs have proven to be an attractive advantage in actual engineering applications owing to their unique mechanical characteristic and better energy absorption ability. The in-plane dynamic crushing behaviors of the honeycombs with various cell-wall angles are studied by means of explicit dynamic finite element simulation. The influences of the cell-wall angle, the impact velocity, and the edge thickness on the macro/microdeformation behaviors, the plateau stresses, and the specific energy absorption of auxetic honeycombs are discussed in detail. Numerical results show, that except for the impact velocity and the edge thickness, the in-plane dynamic performances of auxetic honeycombs also rely on the cell-wall angle. The “> <”-mode local deformation bands form under low- or moderate-velocity impacting, which results in lateral compression shrinkage and shows negative Poisson's ratio during the crushing. For the given impact velocity, the plateau stress at the proximal end and the energy-absorbed ability can be improved by increasing the negative cell angle, the relative density, the impact velocity, and the matrix material strength. When the microcell parameters are the constant, the plateau stresses are proportional to the square of impact velocity.

  9. A big step change : new mobile slurry preparation and crushing technology on the horizon

    Energy Technology Data Exchange (ETDEWEB)

    Budd, G.

    2007-09-15

    The efficiency and productivity of the trucks used in oil sands mining operations can be compromised by unstable terrain, and they consume large amount of fuel. Hydro-transport systems with slurry preparation facilities may soon eliminate the expenses associated with truck and shovel processes. The slurry preparation facilities use on-board reject handling systems to remove large pieces of ore that can't be used in crushers. However, they are hard to move. Researchers are now focusing on the development of a semi-mobile slurry preparation facility that uses mobile crushing and sizing equipment. The equipment uses large tractor tracks instead of wheels and tires, and can accomplish the same amount of work as 6 trucks. Using the system, mine scoop shovels dump ore into a hopper on the mobile unit. The ore is then conveyed to the mobile unit's onboard primary crusher or sizer. Staged crushing is combined with water addition and mixing at the mine site to prepare an oil and slurry ready for hydro-transport. It was concluded that the system may significantly reduce the use of shovel and truck operations in the oil sands industry. 2 figs.

  10. Experimental Characterization of the Energy Absorption of Functionally Graded Foam Filled Tubes Under Axial Crushing Loads

    Science.gov (United States)

    Ebrahimi, Saeed; Vahdatazad, Nader; Liaghat, Gholamhossein

    2018-03-01

    This paper deals with the energy absorption characterization of functionally graded foam (FGF) filled tubes under axial crushing loads by experimental method. The FGF tubes are filled axially by gradient layers of polyurethane foams with different densities. The mechanical properties of the polyurethane foams are firstly obtained from axial compressive tests. Then, the quasi-static compressive tests are carried out for empty tubes, uniform foam filled tubes and FGF filled tubes. Before to present the experimental test results, a nonlinear FEM simulation of the FGF filled tube is carried out in ABAQUS software to gain more insight into the crush deformation patterns, as well as the energy absorption capability of the FGF filled tube. A good agreement between the experimental and simulation results is observed. Finally, the results of experimental test show that an FGF filled tube has excellent energy absorption capacity compared to the ordinary uniform foam-filled tube with the same weight.

  11. Protection by an oral disubstituted hydroxylamine derivative against loss of retinal ganglion cell differentiation following optic nerve crush.

    Science.gov (United States)

    Lindsey, James D; Duong-Polk, Karen X; Dai, Yi; Nguyen, Duy H; Leung, Christopher K; Weinreb, Robert N

    2013-01-01

    Thy-1 is a cell surface protein that is expressed during the differentiation of retinal ganglion cells (RGCs). Optic nerve injury induces progressive loss in the number of RGCs expressing Thy-1. The rate of this loss is fastest during the first week after optic nerve injury and slower in subsequent weeks. This study was undertaken to determine whether oral treatment with a water-soluble N-hydroxy-2,2,6,6-tetramethylpiperidine derivative (OT-440) protects against loss of Thy-1 promoter activation following optic nerve crush and whether this effect targets the earlier quick phase or the later slow phase. The retina of mice expressing cyan fluorescent protein under control of the Thy-1 promoter (Thy1-CFP mice) was imaged using a blue-light confocal scanning laser ophthalmoscope (bCSLO). These mice then received oral OT-440 prepared in cream cheese or dissolved in water, or plain vehicle, for two weeks and were imaged again prior to unilateral optic nerve crush. Treatments and weekly imaging continued for four more weeks. Fluorescent neurons were counted in the same defined retinal areas imaged at each time point in a masked fashion. When the counts at each time point were directly compared, the numbers of fluorescent cells at each time point were greater in the animals that received OT-440 in cream cheese by 8%, 27%, 52% and 60% than in corresponding control animals at 1, 2, 3 and 4 weeks after optic nerve crush. Similar results were obtained when the vehicle was water. Rate analysis indicated the protective effect of OT-440 was greatest during the first two weeks and was maintained in the second two weeks after crush for both the cream cheese vehicle study and water vehicle study. Because most of the fluorescent cells detected by bCSLO are RGCs, these findings suggest that oral OT-440 can either protect against or delay early degenerative responses occurring in RGCs following optic nerve injury.

  12. Protection by an oral disubstituted hydroxylamine derivative against loss of retinal ganglion cell differentiation following optic nerve crush.

    Directory of Open Access Journals (Sweden)

    James D Lindsey

    Full Text Available Thy-1 is a cell surface protein that is expressed during the differentiation of retinal ganglion cells (RGCs. Optic nerve injury induces progressive loss in the number of RGCs expressing Thy-1. The rate of this loss is fastest during the first week after optic nerve injury and slower in subsequent weeks. This study was undertaken to determine whether oral treatment with a water-soluble N-hydroxy-2,2,6,6-tetramethylpiperidine derivative (OT-440 protects against loss of Thy-1 promoter activation following optic nerve crush and whether this effect targets the earlier quick phase or the later slow phase. The retina of mice expressing cyan fluorescent protein under control of the Thy-1 promoter (Thy1-CFP mice was imaged using a blue-light confocal scanning laser ophthalmoscope (bCSLO. These mice then received oral OT-440 prepared in cream cheese or dissolved in water, or plain vehicle, for two weeks and were imaged again prior to unilateral optic nerve crush. Treatments and weekly imaging continued for four more weeks. Fluorescent neurons were counted in the same defined retinal areas imaged at each time point in a masked fashion. When the counts at each time point were directly compared, the numbers of fluorescent cells at each time point were greater in the animals that received OT-440 in cream cheese by 8%, 27%, 52% and 60% than in corresponding control animals at 1, 2, 3 and 4 weeks after optic nerve crush. Similar results were obtained when the vehicle was water. Rate analysis indicated the protective effect of OT-440 was greatest during the first two weeks and was maintained in the second two weeks after crush for both the cream cheese vehicle study and water vehicle study. Because most of the fluorescent cells detected by bCSLO are RGCs, these findings suggest that oral OT-440 can either protect against or delay early degenerative responses occurring in RGCs following optic nerve injury.

  13. Percutaneous Native Renal Biopsy Adequacy: A Successful Interdepartmental Quality Improvement Activity

    Directory of Open Access Journals (Sweden)

    Laurette Geldenhuys

    2015-03-01

    Full Text Available Background: An adequate renal biopsy is essential for diagnosis and treatment of medical renal disease. Objective: We evaluated two initiatives to improve adequacy of renal biopsy samples at our centre. Design: Retrospective determination of renal biopsy adequacy. Setting: Queen Elizabeth II Health Sciences Centre. Patients: Patients undergoing medical renal biopsies. Measurements: Renal biopsy adequacy. Methods: The first initiative was to restrict the performance of biopsies to a smaller group of radiologists and to include a comment on biopsy adequacy in every pathology report. The second initiative was to introduce on-site adequacy assessment by a medical laboratory technologist. Native renal and allograft biopsy adequacies were calculated for three periods: 1 baseline, October 2005 to September 2006; 2 after implementation of the first initiative, January 2007 to September 2011; and 3 after implementation of the second initiative, October 2011 to September 2012. A subset of native renal biopsies was examined to determine if there was a relationship between adequacy and number of passes. Results: The percentages of adequate native renal biopsies during the first, second, and third periods were 31%, 72% and 90%, respectively. This represents a significant increase (40%, p < 0.0001 in adequacy following the first initiative, and another significant increase (18%, p = 0.0003 following the second initiative. The percentages of adequate renal allograft biopsies during the first, second, and third periods were 75%, 56% and 69%, respectively. These changes in adequacy were not statistically significant. In the subset of native renal biopsies examined, a biopsy comprising more than three cores was not associated with increase in adequacy. Limitations: The most important limitation is the lack of generally accepted and applied adequacy criteria limiting generalizability of our findings. Conclusions: Restricting the performance of biopsies to

  14. The effect of cargo on the crush loading of RAM transportation packages in ship collisions

    International Nuclear Information System (INIS)

    Radloff, H.D.; Ammerman, D.J.

    1998-03-01

    Recent intercontinental radioactive material shipping campaigns have focused public and regulatory attention on the safety of transport of this material by ocean-going vessels. One major concern is the response of the vessel and onboard radioactive material (RAM) packages during a severe ship-to-ship collision. These collisions occur at velocities less than the velocity obtained in the Type B package regulatory impact event and the bow of the striking ship is less rigid than the unyielding target used in those tests (Ammerman and Daidola, 1996). This implies that ship impact is not a credible scenario for damaging the radioactive material packages during ship collisions. It is possible, however, for these collisions to generate significant amounts of crush force by the bow of the impacting ship overrunning the package. It is the aim of this paper to determine an upper bound on the magnitude of this crush force taking into account the strength of the radioactive material carrying vessel and any other cargo that may be stowed in the same hold as the radioactive material

  15. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G.; Oertli, D.; Torhorst, J.

    2001-01-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [de

  16. Multiple papillomas in a diamond python, Morelia spilota spilota.

    Science.gov (United States)

    Gull, Jessica M; Lange, Christian E; Favrot, Claude; Dorrestein, Gerry M; Hatt, Jean-Michel

    2012-12-01

    A 4-yr-old male diamond python (Morelia spilota spilota) was evaluated for multiple black papillated exophytic skin proliferations and signs of pneumonia. The histopathologic structure of the skin biopsy specimens led to the diagnosis of a benign papilloma-like neoplasia. In this case, papillomavirus DNA could be amplified from a biopsy sample with a broad range polymerase chain reaction. Nested pan-herpes polymerase chain reaction was negative, and herpesvirus inclusion bodies were not found. Because of the histologically benign nature of the papilloma, the skin proliferations were left untreated. Ten mo after the first presentation, the skin lesions had regressed almost completely; 34 mo later, only scars from the biopsies were left.

  17. Contemporary outcomes in the detection of prostate cancer using transrectal ultrasound-guided 12-core biopsy in Singaporean men with elevated prostate specific antigen and/or abnormal digital rectal examination

    Directory of Open Access Journals (Sweden)

    Alvin Lee

    2015-10-01

    Conclusion: In conclusion, using contemporary 12-core biopsy methods, the local prostate cancer detection rate based on serum PSA and DRE findings has increased over the past decade presumably due to multiple genetic and environmental factors. Post-biopsy sepsis remains an important complication worldwide.

  18. Medially Directed TRUS Biopsy of the Prostate: Clinical Utility and Optimal Protocol

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Seung Hyup

    2012-01-01

    The objective of this study is to determine whether medially directed transrectal ultrasound (TRUS)-guided biopsy is necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen that is equivalent to a systematic 12 core biopsy. A total of 302 patients underwent a TRUS-guided systematic 12 core biopsy consisting of both medial sextant biopsy obtained between the parasagittal line and midline and lateral sextant biopsy obtained between the parasagittal line and lateral border. We obtained cancer detection rates of various biopsy regimens that were produced from a systematic 12 core biopsy. Using a systematic 12 core biopsy, cancer was detected in 116 (38.4%) of 302 patients. No significant difference was observed between cancer detection rates of medial sextant biopsy and lateral sextant biopsy (33.8% versus 31.5%, p >.05). Biopsy regimens that were equivalent to the systematic 12 core regarding cancer detection rate included medially directed cores that were obtained from both medial portions of the apex. Both medially directed biopsy and laterally directed biopsy are necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen.

  19. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  20. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  1. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  2. Investigations into the residual strength of a 2.5 m wide Bushveld Merensky Reef crush pillar

    CSIR Research Space (South Africa)

    Watson, BP

    2008-08-01

    Full Text Available of falls of ground in already dangerous areas, and the larger pillars decrease the extraction ratio. This paper describes the evaluation of stress measurements conducted in two boreholes over a crush pillar with dimensions 2.5 m x 4.0 m, and a height of 1...

  3. Are breast biopsies adequately funded? A process cost and revenue analysis

    International Nuclear Information System (INIS)

    Hahn, M.; Fischbach, E.; Fehm, T.

    2011-01-01

    Purpose: The objective of the study was to determine whether the various breast biopsy procedures specified in the S 3 guidelines are sensibly represented within the current German health system as considered from a cost evaluation perspective. Materials and Methods: This prospectively designed multicenter study analyzed 221 breast biopsies at 7 institutions from 04/2006 to 01/2007. Core needle biopsies, vacuum-assisted biopsies and surgical open biopsies under sonographic or mammographic guidance were evaluated. During an analysis of process costs, the individual process steps were recorded in diagrammatic form and assigned to the true consumption of resources. The actual resource consumption costs were entered. A process-related breakeven analysis was conducted to check whether the reimbursement of individual biopsy types covers the costs. Results: Only sonographically guided core needle biopsy and surgical open biopsy are adequately reimbursed in the current German health system. All other breast biopsies indicate a negative profit margin. The principal reasons for underfunding are found in the area of reimbursement of investment and non-personnel costs. Conclusion: The reimbursement of breast biopsies must be improved in order to guarantee nationwide care of the population using the breast biopsy methods recommended in the S 3 guidelines and to avoid disincentives with respect to breast biopsy indications. (orig.)

  4. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  6. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  7. The value of random biopsies, omentectomy, and hysterectomy in operations for borderline ovarian tumors

    DEFF Research Database (Denmark)

    Kristensen, Gitte Schultz; Schledermann, Doris; Mogensen, Ole

    2014-01-01

    OBJECTIVE: Borderline ovarian tumors (BOTs) are treated surgically like malignant ovarian tumors with hysterectomy, salpingectomy, omentectomy, and multiple random peritoneal biopsies in addition to removal of the ovaries. It is, however, unknown how often removal of macroscopically normal......-appearing tissues leads to the finding of microscopic disease. To evaluate the value of random biopsies, omentectomy, and hysterectomy in operations for BOT, the macroscopic and microscopic findings in a cohort of these patients were reviewed retrospectively. MATERIALS: Women treated for BOT at Odense University.......7%) in International Federation of Gynecology and Obstetrics stage I, 9 (12%) in stage II, and 7 (9.3%) in stage III. The histologic subtypes were serous (68%), mucinous (30.7%), and Brenner type (1.3%). Macroscopically radical surgery was performed in 62 patients (82.7%), and 46 (61.3%) received complete staging...

  8. Phosphotyrosine-based-phosphoproteomics scaled-down to biopsy level for analysis of individual tumor biology and treatment selection.

    Science.gov (United States)

    Labots, Mariette; van der Mijn, Johannes C; Beekhof, Robin; Piersma, Sander R; de Goeij-de Haas, Richard R; Pham, Thang V; Knol, Jaco C; Dekker, Henk; van Grieken, Nicole C T; Verheul, Henk M W; Jiménez, Connie R

    2017-06-06

    Mass spectrometry-based phosphoproteomics of cancer cell and tissue lysates provides insight in aberrantly activated signaling pathways and potential drug targets. For improved understanding of individual patient's tumor biology and to allow selection of tyrosine kinase inhibitors in individual patients, phosphoproteomics of small clinical samples should be feasible and reproducible. We aimed to scale down a pTyr-phosphopeptide enrichment protocol to biopsy-level protein input and assess reproducibility and applicability to tumor needle biopsies. To this end, phosphopeptide immunoprecipitation using anti-phosphotyrosine beads was performed using 10, 5 and 1mg protein input from lysates of colorectal cancer (CRC) cell line HCT116. Multiple needle biopsies from 7 human CRC resection specimens were analyzed at the 1mg-level. The total number of phosphopeptides captured and detected by LC-MS/MS ranged from 681 at 10mg input to 471 at 1mg HCT116 protein. ID-reproducibility ranged from 60.5% at 10mg to 43.9% at 1mg. Per 1mg-level biopsy sample, >200 phosphopeptides were identified with 57% ID-reproducibility between paired tumor biopsies. Unsupervised analysis clustered biopsies from individual patients together and revealed known and potential therapeutic targets. This study demonstrates the feasibility of label-free pTyr-phosphoproteomics at the tumor biopsy level based on reproducible analyses using 1mg of protein input. The considerable number of identified phosphopeptides at this level is attributed to an effective down-scaled immuno-affinity protocol as well as to the application of ID propagation in the data processing and analysis steps. Unsupervised cluster analysis reveals patient-specific profiles. Together, these findings pave the way for clinical trials in which pTyr-phosphoproteomics will be performed on pre- and on-treatment biopsies. Such studies will improve our understanding of individual tumor biology and may enable future p

  9. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  10. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  11. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  12. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    PURPOSE/OBJECTIVE: Although some controversy remains, most authors agree that post-treatment prostatic biopsy is the best measure of local control in prostate cancer. Brachytherapy series reporting post-implant biopsy results have been few in number, limited in size, and involving older open or combined external beam techniques. The present study was undertaken to assess local control rates as determined by post-implant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound directed, transperineal, computer generated, volume technique. METHOD/MATERIALS: From January 1988 to January 1994, 402 patients received permanent I-125 (285, 71%) or Pd-103 (117, 29%) interstitial brachytherapy as primary treatment for prostatic carcinoma at the Northwest Tumor Institute. Of these, 201 have consented to prostatic biopsy at least 12 months post-implant with a median follow-up of 40 months (range of 12 to 83 months). None had received hormone manipulation. A total of 361 biopsies were performed on 201 patients with a range of 1 to 6 yearly biopsies per patient; 91 receiving multiple biopsies. The other 201 patients were either unable (for geographic reasons) or unwilling to submit for biopsy. However, all patients with a rising PSA or clinical suspicion of recurrence underwent biopsy when possible. The 201 biopsy patients presented with a median age of 69 (range 47 to 89). Stages included 51 T1 (25%), 125 T2a (62%), 22 T2b (11%), and 3 T2c (1%). Gleason sums included 69 2-4 (34%), 117 5-6 (58%), 15 7-10 (7%), and 2 ungraded (1%). The initial PSA was 6.6 (range 0.7 to 74.6). There was no significant difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. 143 received I-125 (71%) prescribed to a minimum peripheral dose of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received Pd-103 prescribed to a

  13. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    Science.gov (United States)

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  14. Concrete crushing and sampling, a methodology and technology for the unconditional release of concrete material from decommissioning

    International Nuclear Information System (INIS)

    Baumann, S.; Teunckens, L.; Walthery, R.; Lewandowski, P.; Millen, D.

    2002-01-01

    Belgoprocess started the industrial decommissioning of the main process building of the former Eurochemic reprocessing plant in 1990, after completion of a pilot project. Two small storage buildings for final products from reprocessing were dismantled to verify the assumptions made in a previous paper study on decommissioning, to demonstrate and develop dismantling techniques and to train personnel. Both buildings were emptied and decontaminated to background levels. They were demolished and the remaining concrete debris was disposed of as industrial waste and green field conditions restored. Currently, the decommissioning operations carried out at the main building have made substantial progress. They are executed on an industrial scale and will continue till the end of 2005. In view of the final demolition of the building, a clearance methodology has to be proposed. Application of the methodology applied for the storage buildings of the pilot project is complicated for several reasons. Although this methodology is not rejected as such, an alternative has been studied thoroughly. It considers at least one complete measurement of all concrete structures and the removal of all detected residual radioactivity. This monitoring sequence is followed by a controlled demolition of the concrete structures and crushing of the resulting concrete parts to smaller particles. During the crushing operations, metal parts are separated from the concrete and representative concrete samples are taken. The frequency of sampling meets the prevailing standards. In a further step, the concrete samples are milled, homogenised, and a smaller fraction is sent to the laboratory for analyses. The paper describes the developed concrete crushing and sampling methodology. (authors)

  15. Clinical significance of inadequate endometrial biopsies prior to hysterectomy.

    Science.gov (United States)

    Turney, Emily H; Farghaly, Hanan; Eskew, Ashley M; Parker, Lynn P; Milam, Michael R

    2012-01-01

    To evaluate preoperative clinical risk factors associated with significant uterine histopathologic abnormalities in final hysterectomy specimens in patients with inadequate preoperative endometrial biopsies. This is an institutional review board-approved, retrospective cohort analysis of 469 consecutive patients who underwent preoperative endometrial biopsies with subsequent hysterectomy from January 1, 2005, to December 31, 2009, at the University of Louisville Medical Center. We analyzed risk factors for inadequate biopsy and for final diagnosis of endometrial pathology (defined as endometrial hyperplasia or uterine cancer). Of the 469 preoperative endometrial biopsies reviewed, 26.2% (123/469) were inadequate (IBx) and 73.8% (346/469) were adequate and benign. IBx on endometrial biopsies was associated with a greater risk of having significant uterine histopathologic abnormalities on final hysterectomy specimens (6.5% vs. 2.3%, RR 2.8 [95% CI 1.1-7.3], p = 0.04). Although inadequate endometrial biopsies are a common finding, they can be associated with significant uterine histopathologic abnormalities on final hysterectomy specimens.

  16. [Determination of the 120-day post prostatic biopsy mortality rate].

    Science.gov (United States)

    Canat, G A; Duclos, A; Couray-Targe, S; Schott, A-M; Polazzi, S; Scoazec, J-Y; Berger, F; Perrin, P

    2014-06-01

    Concerning death-rates were reported following prostate biopsy but the lack of contexts in which event occurred makes it difficult to take any position. Therefore, we aimed to determine the 120-day post-biopsy mortality rate. Between 2000 and 2011, 8804 men underwent prostate biopsy in the hospice civils de Lyon. We studied retrospectively, the mortality rate after each of the 11,816 procedures. Biopsies imputability was assessed by examining all medical records. Dates of death were extracted from our local patient management database, which is updated trimestrially with death notifications from the French National Institute for Statistics and Economic Studies. In our study 42 deaths occurred within 120days after 11,816 prostate biopsies (0.36%). Of the 42 records: 9 were lost to follow-up, 3 had no identifiable cause of death, 28 had an intercurrent event ruling out prostate biopsy as a cause of death. Only 2 deaths could be linked to biopsy. We reported at most 2 deaths possibly related to prostate biopsy over 11,816 procedures (0.02%). We confirmed the fact that prostate biopsies can be lethal but this rare outcome should not be considered as an argument against prostate screening given the circumstances in which it occurs. 5. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  18. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  19. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  20. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  1. "DK Crush" Technique for a Tightly Stenosed Conjoined SVG Lesion in a Patient with Acute Coronary Syndrome and Cardiogenic Shock.

    Science.gov (United States)

    Chen, Kuan-Ju; Lee, Wen-Lieng; Liu, Tsun-Jui; Chang, Wei-Chun; Wang, Kuo-Yang; Su, Chieh-Shou

    2015-05-01

    Coronary artery bifurcation disease of saphenous venous graft (SVG) is extremely rare. SVG disease remains a challenging lesion to treat because of increased morbidity and mortality with repeated coronary artery bypass graft surgery (CABG), high rates of periprocedural complications, and in-stent restenosis or occlusion requiring repeat revascularization with percutaneous coronary intervention. Herein, we present the first reported case of using the "DK crush" technique to treat an inverted Y-shaped SVG bifurcation disease in a patient with a prior CABG and new-onset acute coronary syndrome. Arising from our treatment, favorable immediate and mid-term angiographic and clinical outcomes were obtained. Coronary artery bypass surgery (CABG); "DK crush" technique; Saphenous venous graft (SVG).

  2. Evaluation of leachate emissions from crushed rock and municipal solid waste incineration bottom ash used in road construction.

    Science.gov (United States)

    Lidelöw, S; Lagerkvist, A

    2007-01-01

    Three years of leachate emissions from municipal solid waste incineration bottom ash and crushed rock in a full-scale test road were evaluated. The impact of time, construction design, and climate on the emissions was studied, and the predicted release from standard leaching tests was compared with the measured release from the road. The main pollutants and their respective concentrations in leachate from the roadside slope were Al (12.8-85.3 mg l(-1)), Cr (2-125 microg l(-1)), and Cu (0.15-1.9 mg l(-1)) in ash leachate and Zn (1-780 microg l(-1)) in crushed rock leachate. From the ash, the initial Cl(-) release was high ( approximately 20 g l(-1)). After three years, the amount of Cu and Cl(-) was in the same range in both leachates, while that of Al and Cr still was more than one order of magnitude higher in ash leachate. Generally, the release was faster from material in the uncovered slopes than below the pavement. Whether the road was asphalted or not, however, had minor impacts on the leachate quality. During rain events, diluted leachates with respect to, e.g., salts were observed. The leaching tests failed to simulate field leaching from the crushed rock, whereas better agreement was observed for the ash. Comparisons of constituent release from bottom ash and conventional materials solely based on such tests should be avoided.

  3. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  4. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  5. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  6. Behavior of crushed salt under heat source in boreholes in a salt mine (Amelie Mine, Alsace Potash Mines, France)

    International Nuclear Information System (INIS)

    Ghoreychi, M.

    1991-01-01

    The study of thermomechanical interaction between rock salt and crushed salt, used as a backfilling material at the final stage of radioactive waste disposal in salt formations, led to perform an in situ test at the Amelie Mine(The Alsace Potash Mines in France). The field tests site is located at a depth of 520m and the tests were performed in six parallel boreholes. Five boreholes were backfilled using three types of crushed salt, changing by their grain size (fine = 0.4 mm; natural = 1 mm; coarse = 2 mm). The sixth borehole was not backfilled in order to witness for rock salt behavior without backfilling confinement. Except the first borehole used as a pilot test, the four backfilled boreholes were heated during four months with two levels of heat output (1.6 kW, then 2.2 kW). Cooling was also followed during four months after heating interruption. The maximum of temperature obtained on the wall of the backfilled boreholes was about 100 0 C during the first field test and 130 0 C during the second. The thermal diffusivity of rock mass and the coefficient of heat exchange by convection are studied. In spite of the case that the crushed salt thermal conductivity is initially ten times less than of rock salt, no excessive temperature concentration was obtained on the heat sources

  7. Leaching behaviour of copper slag, construction and demolition waste and crushed rock used in a full-scale road construction.

    Science.gov (United States)

    Lidelöw, Sofia; Mácsik, Josef; Carabante, Ivan; Kumpiene, Jurate

    2017-12-15

    The leaching behaviour of a road construction with fayalitic copper slag, recycled concrete and crushed rock as sub-base materials was monitored over ten years. All studied materials used in the road construction, including crushed rock, contained concentrations of several elements exceeding the guideline values recommended by the Swedish EPA for total element concentrations for waste materials used in constructions. Despite that, leaching from the road construction under field conditions in general was relatively low. The leachates from the recycled materials contained higher concentrations of several constituents than the leachates from the reference section with crushed rock. The leaching of the elements of interest (Cr, Mo, Ni, Zn) reached peak concentrations during the second and fourth (Cu) years and decreased over the observation period to levels below the Swedish recommended values. Carbonation of the concrete aggregates caused a substantial but short-term increase in the leaching of oxyanions such as chromate. The environmental risks related to element leaching are highest at the beginning of the road life. Ageing of materials or pre-treatment through leaching is needed prior to their use in construction to avoid peak concentrations. Also, the design of road constructions should be adjusted so that recycled materials are covered with low-permeability covers, which would minimize the exposure to atmospheric precipitation and weathering. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Epidemiology of biopsy-proven glomerulonephritis in Queensland adults.

    Science.gov (United States)

    Jegatheesan, Dev; Nath, Karthik; Reyaldeen, Reza; Sivasuthan, Goutham; John, George T; Francis, Leo; Rajmokan, Mohana; Ranganathan, Dwarakanathan

    2016-01-01

    There is a paucity of data pertaining to the incidence of biopsy-proven glomerulonephritis (GN) in Australia. This retrospective study aims to review the data from all adult native renal biopsies performed in the state of Queensland from 2002 to 2011--comparing results with centres from across the world. Pathology reports of 3697 adult native kidney biopsies were reviewed, of which 2048 had GN diagnoses. Age, gender, clinical indication and histopathology findings were compared. The average age at biopsy was 48 ± 17 years. Male preponderance was noted overall (∼60%), with lupus nephritis being the only individual GN with female predilection. The average rate of biopsy was 12.04 per hundred thousand people per year (php/yr). Nephrotic and nephritic syndromes comprised approximately 75% of all clinical indications that lead to GN diagnoses. IgA nephropathy (1.41 php/yr) was the most common primary GN followed by focal segmental glomerulosclerosis (1.02 php/yr) and crescentic GN (0.73 php/yr). Diabetic nephropathy (0.84 php/yr), lupus nephritis (0.69 php/yr) and amyloidosis (0.19 php/yr) were the most commonly identified secondary GN. IgA nephropathy is the predominant primary GN in Queensland, and nephrotic syndrome the most common indication for a renal biopsy. While crescentic GN incidence has significantly increased with time, focal segmental glomerulosclerosis incidence has not shown any trend. Incidence of GN overall appears to increase with age. The annual rate of biopsy in this study appears lower than previously published in an Australian population. © 2015 Asian Pacific Society of Nephrology.

  9. Operator dependent choice of prostate cancer biopsy has limited impact on a gene signature analysis for the highly expressed genes IGFBP3 and F3 in prostate cancer epithelial cells.

    Directory of Open Access Journals (Sweden)

    Zhuochun Peng

    Full Text Available BACKGROUND: Predicting the prognosis of prostate cancer disease through gene expression analysis is receiving increasing interest. In many cases, such analyses are based on formalin-fixed, paraffin embedded (FFPE core needle biopsy material on which Gleason grading for diagnosis has been conducted. Since each patient typically has multiple biopsy samples, and since Gleason grading is an operator dependent procedure known to be difficult, the impact of the operator's choice of biopsy was evaluated. METHODS: Multiple biopsy samples from 43 patients were evaluated using a previously reported gene signature of IGFBP3, F3 and VGLL3 with potential prognostic value in estimating overall survival at diagnosis of prostate cancer. A four multiplex one-step qRT-PCR test kit, designed and optimized for measuring the signature in FFPE core needle biopsy samples was used. Concordance of gene expression levels between primary and secondary Gleason tumor patterns, as well as benign tissue specimens, was analyzed. RESULTS: The gene expression levels of IGFBP3 and F3 in prostate cancer epithelial cell-containing tissue representing the primary and secondary Gleason patterns were high and consistent, while the low expressed VGLL3 showed more variation in its expression levels. CONCLUSION: The assessment of IGFBP3 and F3 gene expression levels in prostate cancer tissue is independent of Gleason patterns, meaning that the impact of operator's choice of biopsy is low.

  10. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  11. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  12. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  13. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  14. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  15. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    International Nuclear Information System (INIS)

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun Kyung

    2014-01-01

    To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assisted excision, n=35) or breast ultrasonography (n=20). Of the 126 patients who underwent surgical excision or US-guided vacuum-assisted excision, 114 patients were diagnosed with benign lesions, 10 patients with borderline lesions (benign phyllodes tumor), and two patients with malignant phyllodes tumors. The probabilities of lesions being benign, borderline and malignant were 91.8% (134/146), 6.8% (10/146), and 1.4% (2/146), respectively. Of 13 patients who had growing masses on follow-up ultrasonography, three (23.1%) were non-benign (two benign phyllodes tumors and one malignant phyllodes tumor). US-guided core needle biopsy of probably benign breast mass 2 cm or larger was accurate (98.6%) enough to rule out malignancy. But, it was difficult to rule out borderline lesions even when they were diagnosed as benign.

  16. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  17. Pleural biopsy for indeterminate cases of pleural effusion | Ukadike ...

    African Journals Online (AJOL)

    Materials and Methods: This is a retrospective study of all consecutive cases of pleural biopsies done for indeterminate cause of pleural effusion in the University of Benin Teaching Hospital from December 2008 to May 2010, a total of 18months. Blind pleural biopsy was carried out using the Abram's Pleural Biopsy Needle.

  18. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  19. Extraosseous Multiple Myeloma with Retroperitoneal Manifestation: A Case Report

    International Nuclear Information System (INIS)

    Berdugo, Juan Oswaldo; Nieto, Sonia Janeth; Garzon, Julian Gonzalo

    2008-01-01

    This paper presents a case of a 57 years old man (patient of Hospital Militar Central of Bogota, Colombia) with weight loss and a mass in the right clavicle. Plain film radiography shows a lytic lesion in the sternum side of the clavicle. biopsy reports a plasmacytomas, radiotherapy was performed. Three years later lesions of similar characteristics within ribs and a focal lesion in left testicle were detected. The diagnosis was multiple myeloma, Chemotherapy and orquidectomy were performed. One year after, patient complained of diffuse abdominal pain and loss weight, contrast abdominal CT was performed. Computed tomography showed a left heterogeneous mass with irregular contours that involved the retroperitoneal space occupying its three compartments. Biopsy was performed and reported pleomorphicplasmocytic proliferation with nuclear enlargement and hyperchromic nuclei consistent with multiple myeloma with abdominal involvement.

  20. A 17-gene assay to predict prostate cancer aggressiveness in the context of Gleason grade heterogeneity, tumor multifocality, and biopsy undersampling.

    Science.gov (United States)

    Klein, Eric A; Cooperberg, Matthew R; Magi-Galluzzi, Cristina; Simko, Jeffry P; Falzarano, Sara M; Maddala, Tara; Chan, June M; Li, Jianbo; Cowan, Janet E; Tsiatis, Athanasios C; Cherbavaz, Diana B; Pelham, Robert J; Tenggara-Hunter, Imelda; Baehner, Frederick L; Knezevic, Dejan; Febbo, Phillip G; Shak, Steven; Kattan, Michael W; Lee, Mark; Carroll, Peter R

    2014-09-01

    Prostate tumor heterogeneity and biopsy undersampling pose challenges to accurate, individualized risk assessment for men with localized disease. To identify and validate a biopsy-based gene expression signature that predicts clinical recurrence, prostate cancer (PCa) death, and adverse pathology. Gene expression was quantified by reverse transcription-polymerase chain reaction for three studies-a discovery prostatectomy study (n=441), a biopsy study (n=167), and a prospectively designed, independent clinical validation study (n=395)-testing retrospectively collected needle biopsies from contemporary (1997-2011) patients with low to intermediate clinical risk who were candidates for active surveillance (AS). The main outcome measures defining aggressive PCa were clinical recurrence, PCa death, and adverse pathology at prostatectomy. Cox proportional hazards regression models were used to evaluate the association between gene expression and time to event end points. Results from the prostatectomy and biopsy studies were used to develop and lock a multigene-expression-based signature, called the Genomic Prostate Score (GPS); in the validation study, logistic regression was used to test the association between the GPS and pathologic stage and grade at prostatectomy. Decision-curve analysis and risk profiles were used together with clinical and pathologic characteristics to evaluate clinical utility. Of the 732 candidate genes analyzed, 288 (39%) were found to predict clinical recurrence despite heterogeneity and multifocality, and 198 (27%) were predictive of aggressive disease after adjustment for prostate-specific antigen, Gleason score, and clinical stage. Further analysis identified 17 genes representing multiple biological pathways that were combined into the GPS algorithm. In the validation study, GPS predicted high-grade (odds ratio [OR] per 20 GPS units: 2.3; 95% confidence interval [CI], 1.5-3.7; p<0.001) and high-stage (OR per 20 GPS units: 1.9; 95% CI, 1