WorldWideScience

Sample records for multiphase gutta-percha obturation

  1. Efficacy of ProTaper Retreatment System in Root Canals Obturated with Gutta-Percha Using Two Different Sealers and GuttaFlow

    Science.gov (United States)

    Siotia, Jaya; Acharya, Shashi Rashmi; Gupta, Sunil Kumar

    2011-01-01

    Objective. To compare the efficacy of ProTaper retreatment files in removing three different obturating materials. Study Design. Forty-five human, single-rooted premolars were divided into three experimental groups. Group 1 was obturated with gutta-percha and AH Plus sealer, Group 2 was obturated with gutta-percha and zinc oxide eugenol sealer, and Group 3 was obturated with GuttaFlow. Retreatment was done using the ProTaper universal rotary retreatment files. Root halves were visualized using magnifying loops at 3X magnification and optical stereomicroscope at 10X magnification. Images were analyzed using AutoCAD 2004 software to calculate area of the remaining debris in the canal. For statistical analysis were used variance test and ANOVA. Results. Total debris/canal area ratio between the three groups showed a statistically significant difference (P < 0.001). Conclusion. ProTaper retreatment system did not produce completely clean canals in any of the groups. However, it had the best efficacy towards removing silicon based obturating material GuttaFlow. PMID:22114598

  2. APICAL SEAL BETWEEN ADHESIVE ROOT CANAL OBTURATION SYSTEM AND GUTTA-PERCHA/AH-PLUS SEALER: AN IN VITRO COMPARISON STUDY

    Directory of Open Access Journals (Sweden)

    Girish

    2016-03-01

    Full Text Available BACKGROUND Three dimensional obturation of the root canal is important for success of root canal treatment. Microleakage is one of the reason for root canal failure. Numerous materials have been used for obturation of which Gutta-percha is the most successful with variety of sealers. One of the recent material to further improve root canal treatment success rate is use of Resilon with Epiphany root canal sealer to apply adhesive concepts in to endodontics. An adhesive bond forms between Epiphany sealer, Resilon and dentin, making it monolithic hence less microleakage if any significantly. METHODS 60 single rooted mandibular premolars were dissected at cement enamel junction with diamond disc. Root canals were explored and working length measured using K file. Root canals of all 60 samples were prepared with ProTaper and irrigated with 5% sodium hypochlorite and 17% EDTA solution. Teeth were divided in to group A and B, each having 30 samples. Group A teeth obturated with Resilon Epiphany obturation system and group B with Gutta-percha and AH-plus sealer. All specimens were stored in incubator for 30 days. Clearing process of samples done with Robertson’s technique to make them transparent. All the specimens were immersed in 2% methylene blue dye solution for 7 days. Specimens were then examined under stereomicroscope with 10x magnification to measure dye penetration in mm with image analysis software. The data collected were analysed statistically. RESULTS This study showed that Resilon Epiphany group has a mean leakage of 1.2307, while the Gutta-percha/AH-plus had a mean leakage of 3.6133. There was statistically significant differences between Resilon and Gutta-percha groups. CONCLUSIONS 1. Resilon Epiphany group showed less apical microleakage than Gutta-percha/AH-plus obturation. 2. Based on result obtained it is suggested that Resilon Epiphany can be recommended for root canal obturation.

  3. An in-vitro comparison of the radiographic and actual gutta-percha terminus.

    Science.gov (United States)

    Namazikhah, M S; Ghiai, M; Parkin, M J; Puccinelli, L

    2000-06-01

    The purpose of this study was to investigate the difference between the radiographic gutta-percha terminus and the actual gutta-percha terminus of human molars by comparing radiographic obturation results with actual obturation results. Forty maxillary palatal roots and 50 mandibular distal roots were randomly selected from a population of 540. They were then mounted in stone and radiographed. Conventional endodontic therapy was completed using stainless-steel K files and lateral condensation. Each radiographic gutta-percha terminus was evaluated under 4.5x magnification by three examiners following the completion of root canal therapy. These results were recorded. Each tooth was then removed from its mounting, and the actual gutta-percha terminus was evaluated under 4.5x magnification. These results were recorded and compared to the radiographic gutta-percha terminus results. In all 90 teeth examined, the actual gutta-percha terminus was equal to or longer than the radiographic gutta-percha terminus. In the 50 mandibular distal roots, the actual gutta-percha terminus averaged 0.645 mm longer than the radiographic gutta-percha terminus. In the 40 maxillary palatal roots, this difference measured 0.6375 mm.

  4. IN VITRO COMPARISON OF GUTTA-PERCHA-FILLED AREA PERCENTAGES IN ROOT CANALS INSTRUMENTED AND OBTURATED WITH DIFFERENT TECHNIQUES*

    Directory of Open Access Journals (Sweden)

    Ayça YILMAZ

    2017-04-01

    Full Text Available Purpose: To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA. Materials and Methods: One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20 according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC, G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. Results: The mean of the PGFA in Thermafil (G2, ProTaper-Obturator (G5 and HEROfill (G8 groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. Conclusion: The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  5. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    Science.gov (United States)

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  6. Evaluation of microleakage in single-rooted teeth obturated with thermoplasticized gutta-percha using various endodontic sealers: an in-vitrostudy

    International Nuclear Information System (INIS)

    Lone, M.M.; Khan, F.; Lone, M.A.

    2018-01-01

    Objective:To compare apical microleakage of extracted, single-rooted teeth obturated with thermoplasticized injectable gutta-percha using two different endodontic sealers (calcium-hydroxide and resin based). Study Design:An experimental study. Place and Duration of Study:The Aga Khan University Hospital (AKUH), Dental Clinics and Laboratory from June to September 2015. Methodology:The study was conducted using extracted teeth. After access cavities were made, cleaning and shaping of root canals was done in 70 teeth. Teeth were randomly allocated into two groups and obturated with thermoplasticized injectable gutta-percha (Obtura II) using two sealers (Sealapex vs.AH plus). After immersing the teeth in 2.0% methylene blue, they were split longitudinally, viewed under light microscope (magnification X4) and images were taken by a camera connected to microscope. The extent of dye penetration was assessed from apex to its coronal part and recorded in millimeters. Independent sample t-test was used to compare microleakage in the two groups. Pearson correlation coefficient was used for inter-examiner reliability of dye penetration measurements. A p-value of <0.05 was taken as statistically significant. Results:Teeth obturated with Obtura II gutta-percha with AH plus sealer had a mean dye penetration of 1.20 +- 0.79 mm. This was significantly better than Obtura II with Sealapex sealer (p=0.003). Conclusion:Obtura II-AH plus sealer was a better combination for obturation as it showed a lesser degree of microleakage. Obtura II with Sealapex group showed higher microleakage, so this combination should be avoided in single-rooted teeth. (author)

  7. An evaluation of .06 tapered gutta-percha cones for filling of .06 taper prepared curved root canals.

    Science.gov (United States)

    Gordon, M P J; Love, R M; Chandler, N P

    2005-02-01

    To compare the area occupied by gutta-percha, sealer, or void in standardized .06 tapered prepared simulated curved canals and in mesio-buccal canals of extracted maxillary first molars filled with a single .06 gutta-percha point and sealer or lateral condensation of multiple .02 gutta-percha points and sealer. Simulated canals in resin blocks with either a 30 degrees curve and radius of 10.5 mm (n = 20) or a 58 degrees curve and 4.7 mm radius (n = 20) and curved mesio-buccal canals of extracted maxillary first molars (n = 20) were prepared using .06 ProFiles in a variable tip crown-down sequence to an apical size 35 at 0.5 mm from the canal terminus or apical foramen. Ten 30 degrees and 58 degrees curved resin canals and 10 canals in the extracted teeth group were obturated with .02 taper gutta-percha cones and AH 26 sealer using lateral condensation. The time required to obturate was recorded. The remaining canals were obturated with a single .06 taper gutta-percha cone and AH 26 sealer. Excess gutta-percha was removed from the specimens using heat and the warm mass vertically condensed. Horizontal sections were cut at 0.5, 1.5, 2.5, 4.5, 7.5 and 11.5 mm from the canal terminus or apical foramen. Colour photographs were taken using an Olympus 35 mm camera attached to a stereomicroscope set at x40 magnification, and then digitized using a flatbed scanner. The cross-sectional area of the canal contents was analysed using Adobe PhotoShop. The percentage of gutta-percha, sealer or voids to the total root canal area were derived and data analysed using unpaired Student's t-test and the Mann-Whitney U-test. In the 30 degrees curved canals the levels had between 94 and 100% of the area filled with gutta-percha with no significant difference (P > 0.05) between the lateral condensation and single cone techniques. In the 58 degrees curved canals the levels had 92-99% of the area filled with gutta-percha, with the single cone technique having significantly (P 0.05) between

  8. Differentiation of Dental Pulp Stem Cells on Gutta-Percha Scaffolds

    Directory of Open Access Journals (Sweden)

    Liudi Zhang

    2016-05-01

    Full Text Available Advances in treatment of tooth injury have shown that tooth regeneration from the pulp was a viable alternative of root canal therapy. In this study, we demonstrated that Gutta-percha, nanocomposites primarily used for obturation of the canal, are not cytotoxic and can induce differentiation of dental pulp stem cells (DPSC in the absence of soluble mediators. Flat scaffolds were obtained by spin coating Si wafers with three Gutta-percha compounds: GuttaCore™, ProTaper™, and Lexicon™. The images of annealed surfaces showed that the nanoparticles were encapsulated, forming surfaces with root mean square (RMS roughness of 136–211 nm. Then, by culturing DPSC on these substrates we found that after some initial difficulty in adhesion, confluent tissues were formed after 21 days. Imaging of the polyisoprene (PI surfaces showed that biomineral deposition only occurred when dexamethasone was present in the media. Spectra obtained from the minerals was consistent with that of hydroxyapatite (HA. In contrast, HA deposition was observed on all Gutta-percha scaffolds regardless of the presence or absence of dexamethasone, implying that surface roughness may be an enabling factor in the differentiation process. These results indicate that Gutta-percha nanocomposites may be good candidates for pulp regeneration therapy.

  9. [Clinical applications of thermoplasticized gutta percha].

    Science.gov (United States)

    Vincente Gómez, A

    1990-01-01

    Step-Back technique or similar is the method of choice for the thermoplasticized gutta-percha. There are no significant differences in the apical seal produced by different filling techniques. There is a little volumetric reduction, similar than in the regular gutta-percha points, when cooling gutta-percha. The results of a clinical study about thermoplasticized gutta-percha with and without sealer are similar than in a control group filled by lateral condensation.

  10. Removal of Gutta-Percha/Zinc-Oxide-Eugenol Sealer or Gutta-Percha/Epoxy Resin Sealer from Severely Curved Canals: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Santhoshini Reddy

    2011-01-01

    Full Text Available The aim of this study was to compare the cleanliness of root canal walls after retreatment using two rotary retreatment files to hand instruments in severely curved canals obturated with gutta-percha and two different sealers. Single rooted mandibular premolars (n=90 with root curvatures were instrumented and obturated with gutta-percha and an epoxy resin (Group 1, n=45 or zinc oxide eugenol sealer (Group 2, n=45. Following retreatment of the specimens (n=15 ProTaper Universal Retreatment Files (Subgroup B or R-Endo retreatment files (Subgroup C after 1 month, split specimens were examined under a stereomicroscope and the percentage of remaining root filling material was statistically compared using one way ANOVA with Bonferroni adjustment for multiple comparisons (P=0.05. The R-Endo system performed significantly better than the other two file systems (P<0.05. None of the systems used in this study cleaned root canals thoroughly. The R-Endo system did provide cleaner walls when compared to the other instruments used. The type of root filling materials had an impact on the outcomes with all techniques.

  11. Efficacy of Different Nickel-Titanium Instruments in Removing Gutta-percha during Root Canal Retreatment.

    Science.gov (United States)

    Özyürek, Taha; Demiryürek, Ebru Özsezer

    2016-04-01

    The aim of this study was to compare the cleanliness of root canal walls after retreatment using ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Twisted File Adaptive (TFA; Axis/SybronEndo, Orange, CA), Reciproc (PRC; VDW, Munich, Germany), and ProTaper Universal retreatment (PTR, Dentsply Maillefer) nickel-titanium systems and the time required for gutta-percha and sealer removal. Eighty human maxillary central incisors with single and straight root canals were instrumented up to #40.02 with manual K-files (Dentsply Maillefer) and obturated using the continuous wave of condensation technique. Removal of the gutta-percha and sealer was performed using 1 of the following nickel-titanium systems: PTN, TFA, RPC, or PTR. The teeth were sectioned, and digital images were captured. The photographs were analyzed using AutoCAD software (Autodesk, San Rafael, CA). Also, the total time required for gutta-percha removal was calculated by a chronometer. The total retreatment time was significantly shorter in the PTR group compared with the other groups (P < .05). There was a significant difference between the groups according to the total residual gutta-percha and sealer (P < .05). The PTN and PTR groups left significantly less gutta-percha and sealer remnant than the TFA and RPC groups (P < .05). Within the limitations of this study, the PTN and the PTR groups showed less residual gutta-percha and sealer than the TFA and RPC groups. The time required for gutta-percha and sealer removal was similar for all the groups, except for the PTR group. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. The comparison of microbial leakage in roots filled with resilon and gutta-percha: An in vitro study.

    Science.gov (United States)

    Shashidhar, C; Shivanna, Vasundhara; Shivamurthy, Gb; Shashidhar, Jyothi

    2011-01-01

    The objective of this study was to compare bacterial leakage using streptococcus mutans through gutta-percha and a thermoplastic synthetic polymer based root canal filling material (Resilon) using two filling techniques. A total of 90 single-rooted extracted human teeth were subjected for the study. Teeth were divided into 6 groups of 10 and 3 control groups of 10 teeth each. All the samples were decoronated and the coronal surfaces of the roots were prepared perpendicular to the long axis of the root with a high-speed handpiece and a multipurpose bur using air water spray. The length of all the roots was prepared approximately 16 mm from the coronal surface to the apex of the root. Roots were filled using lateral and vertical condensation techniques with gutta-percha and AH26 sealer (Group 1 and 2) or with gutta-percha and epiphany sealer (Group 3 and 4). Group 5 and 6 were filled with Resilon and epiphany sealer using the lateral and vertical condensation techniques. A split chamber microbial leakage model was used in which S. mutans placed in the upper chamber could reach the lower chamber only through the filled root canal. Group 7 and 8 (positive control) were filled with Resilon and gutta-percha without sealer and tested with bacteria, whereas Group 7 (negative control) was sealed with wax to test the seal between the chambers. Data were analyzed using Kruskal-Wallis test and Mann-Whitney U test. All positive groups (Group 7 and 8) showed leakage within 1 hour of the start of the study (100%), whereas none of the negative control (Group 9) leaked. The roots obturated with Resilon and epiphany (Group 5 and 6) showed minimal leakage, i.e., each with 6 leakages, which was significantly less than gutta-percha (Group 1-4), in which approximately 80% of specimens with either sealer or techniques leaked. Kruskal-Wallis test showed statistical significance when all groups were compared (P<0.05). Mann-Whitney U test compared the respective groups and found Resilon

  13. Comparative evaluation of the vertical fracture resistance of endodontically treated roots filled with Gutta-percha and Resilon: a meta-analysis of in vitro studies.

    Science.gov (United States)

    Tan, Minmin; Chai, Zhaowu; Sun, Chengjun; Hu, Bo; Gao, Xiang; Chen, Yunjia; Song, Jinlin

    2018-06-13

    Teeth treated endodontically are more susceptible to vertical root fracture (VRF). Some studies have suggested that obturating the root canals with Gutta-percha or Resilon can reinforce endodontically treated teeth, but a few others have presented conflicting results. These inconsistent results cannot guide clinicians in determining clinical approaches. The objective of this meta-analysis is to evaluate and compare the vertical fracture resistance of endodontically treated root canals obturated with Gutta-percha/AH plus and the Resilon system. Comprehensive literature searches were performed in the PubMed, Cochrane Library, ScienceDirect, Web of Science and Embase databases. The titles and abstracts of all of the retrieved articles were independently assessed by two authors according to predefined selection criteria. Data in the included articles were independently extracted. Statistical analyses were conducted using Review Manager 5.3 and Stata 12.0 software. The pooled standardized mean differences (SMDs) with 95% confidence intervals (CIs) were calculated for the outcome indicators. The level of statistical significance was set at p < 0.05. The Cochran Q test (I 2 test) was used to test for heterogeneity among studies. Fourteen randomized controlled in vitro trials were included in the meta-analysis. The results demonstrated that the vertical root fracture resistance of unprepared and unfilled roots was significantly higher than that of roots obturated with Gutta-percha/AH plus (SMD = - 0.69, 95% CI = - 1.34 to - 0.04, p = 0.04) or the Resilon system (SMD = - 0.54, 95% CI = - 1.07 to - 0.00, p = 0.05). The differences in fracture resistance between the roots filled with Gutta-percha/AH plus and the prepared unfilled root canals was not significant (SMD = 0.59, 95% CI = - 0.02 to 1.21, p = 0.06). Roots obturated with Resilon had higher fracture resistance than instrumented unfilled roots (SMD = 0.83, 95

  14. Efficacy of protaper next and protaper universal retreatment systems in removing gutta-percha in curved root canals during root canal retreatment.

    Science.gov (United States)

    Ozyurek, Taha; Ozsezer-Demiryurek, Ebru

    2017-01-01

    The aim of this study was to compare the cleanliness of root canal walls after retreatment using ProTaper Next (PTN), ProTaper Universal Retreatment (PTR) nickel-titanium (NiTi) systems and Hedström hand files in curved mesial canals of mandibular molar teeth and the time required for gutta-percha and sealer removal. Ninety mandibular molar teeth with curved mesial roots were instrumented up to #35.04 with Mtwo NiTi rotary instruments and obturated using the continuous wave of condensation technique. Removal of gutta-percha and sealer was performed using one of the following: PTN and PTR NiTi systems and Hedström hand files. Samples were placed on the VistaScan phosphor plates in the mesio-distal direction and the radiographs were taken. The digital radiographs were analyzed using AutoCAD software. Also, the total time required for gutta-percha removal was calculated by a chronometer. The total retreatment time was significantly shorter in the PTN and PTR groups compared with the manual group (p<0.05). There was a significant difference between the groups according to the total residual gutta-percha and sealer (p<0.05). The PTN and PTR groups left significantly less gutta-percha and sealer remnant than the manual group (p<0.001). Within the limitations of this study, the PTN and PTR groups showed less residual gutta-percha and sealer than the manual group. The NiTi rotary systems were significantly faster than the manual group in the time required for gutta-percha and sealer removal.

  15. An in vitro Comparison of Bond Strength of Different Sealers/Obturation Systems to Root Dentin Using the Push-Out Test at 2 Weeks and 3 Months after Obturation.

    Science.gov (United States)

    Yap, Wai Ying; Che Ab Aziz, Zeti Adura; Azami, Noor Hayati; Al-Haddad, Afaf Yahya; Khan, Asfand Ali

    2017-01-01

    To evaluate the push-out bond strength and failure modes of different sealers/obturation systems to intraradicular dentin at 2 weeks and 3 months after obturation compared to AH Plus®/gutta-percha. A total of 180 root slices from 60 single-canal anterior teeth were prepared and assigned to 5 experimental groups (n = 36 in each group), designated as G1 (AH Plus®/gutta-percha), G2 (TotalFill BC™ sealer/BC-coated gutta-percha), G3 (TotalFill BC™ sealer/gutta-percha), G4 (EndoREZ® sealer/EndoREZ®-coated gutta-percha), and G5 (EndoREZ® sealer/gutta-percha). Push-out bond strengths of 18 root slices in each group were assessed at 2 weeks and the other 18 at 3 months after obturation using a universal testing machine. Data were analyzed using repeated measures ANOVA. An independent t test was used to compare the mean push-out bond strength for each group at 2 weeks and 3 months after obturation. The mean push-out bond strengths of G4 and G5 were significantly lower than those of G1, G2, and G3 (p strengths of G2 (3.69 ± 1.20 MPa) and G3 (2.84 ± 0.83 MPa) were higher at 3 months compared to 2 weeks after obturation (G2: 1.74 ± 0.43 MPa, G3: 1.33 ± 0.29 MPa). The TotalFill BC™ obturation system (G2) and the TotalFill BC™ sealer/gutta-percha (G3) showed comparable bond strength to AH Plus®. Their bond strength increased over time, whereas the EndoREZ® obturation system (G4) and EndoREZ sealer (G5) had low push-out bond strength which decreased over time. © 2017 The Author(s) Published by S. Karger AG, Basel.

  16. EFFICACY OF PROTAPER NEXT AND PROTAPER UNIVERSAL RETREATMENT SYSTEMS IN REMOVING GUTTA-PERCHA IN CURVED ROOT CANALS DURING ROOT CANAL RETREATMENT

    Directory of Open Access Journals (Sweden)

    Taha ÖZYÜREK

    2017-04-01

    Full Text Available Purpose: The aim of this study was to compare the cleanliness of root canal walls after retreatment using ProTaper Next (PTN, ProTaper Universal Retreatment (PTR nickel-titanium (NiTi systems and Hedström hand files in curved mesial canals of mandibular molar teeth and the time required for gutta-percha and sealer removal. Materials and Methods: Ninety mandibular molar teeth with curved mesial roots were instrumented up to #35.04 with Mtwo NiTi rotary instruments and obturated using the continuous wave of condensation technique. Removal of gutta-percha and sealer was performed using one of the following: PTN and PTR NiTi systems and Hedström hand files. Samples were placed on the VistaScan phosphor plates in the mesio-distal direction and the radiographs were taken. The digital radiographs were analyzed using AutoCAD software. Also, the total time required for gutta-percha removal was calculated by a chronometer. Results: The total retreatment time was significantly shorter in the PTN and PTR groups compared with the manual group (p<0.05. There was a significant difference between the groups according to the total residual gutta-percha and sealer (p<0.05. The PTN and PTR groups left significantly less gutta-percha and sealer remnant than the manual group (p<0.001. Conclusion: Within the limitations of this study, the PTN and PTR groups showed less residual gutta-percha and sealer than the manual group. The NiTi rotary systems were significantly faster than the manual group in the time required for gutta-percha and sealer removal.

  17. Surface modification of gutta-percha cones by non-thermal plasma

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Maíra, E-mail: maira@metalmat.ufrj.br [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Menezes, Marilia Santana de Oliveira [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Gomes, Brenda Paula Figueiredo de Almeida [Department of Restorative Dentistry, Endodontics Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP (Brazil); Barbosa, Carlos Augusto de Melo [Department of Clinical Dentistry, Endodontic Division, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Athias, Leonardo [Social Indicators Division, Brazilian Institute of Geography and Statistics, Rio de Janeiro, RJ (Brazil); Simão, Renata Antoun [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil)

    2016-11-01

    This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1 min; Argon: treatment with Argon plasma for 1 min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. - Highlights: • Argon plasma did not change the gutta-percha surface. • Oxygen plasma led to topographic changes. • Both treatments chemically modified the gutta-percha surface. • Treatments increased the surface free energy and favored the wettability of sealers. • Plasma

  18. Surface modification of gutta-percha cones by non-thermal plasma

    International Nuclear Information System (INIS)

    Prado, Maíra; Menezes, Marilia Santana de Oliveira; Gomes, Brenda Paula Figueiredo de Almeida; Barbosa, Carlos Augusto de Melo; Athias, Leonardo; Simão, Renata Antoun

    2016-01-01

    This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1 min; Argon: treatment with Argon plasma for 1 min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. - Highlights: • Argon plasma did not change the gutta-percha surface. • Oxygen plasma led to topographic changes. • Both treatments chemically modified the gutta-percha surface. • Treatments increased the surface free energy and favored the wettability of sealers. • Plasma

  19. The effect of using an inverted master cone in a lateral compaction technique on the density of the gutta-percha fill.

    Science.gov (United States)

    Wu, Min-Kai; de Groot, Sjoerd D; van der Sluis, Luc W M; Wesselink, Paul R

    2003-09-01

    We sought to measure and calculate the percentage of the gutta-percha-filled area in the apical root canal after the use of a standardized or inverted master cone in cold lateral compaction.Study design Two groups of extracted mandibular premolars with a single canal were instrumented with instruments of the same size; furthermore, they were obturated with laterally compacted gutta-percha cones with AH26 used as a sealer. In the first group, a standardized master cone was used with its narrow end in an apical position, whereas in the other group, an inverted master cone was used with its wide end in an apical position. The 2 master cones had the same apical diameter and fit in the apical canal. After lateral compaction, horizontal sections were cut at a level 3 and 5 mm from the apex of each filled tooth. Photographs of the sections were taken by using a microscope equipped with a digital camera; the photos were then scanned as tagged-image file format images. The cross-sectional area of the canal and the gutta-percha were measured by using an image-analysis program. The percentage of gutta-percha-filled area was calculated. At both levels, the inverted master cone produced a significantly higher percentage, statistically, of gutta-percha-filled area than did the standardized master cone (P =.001 at 3 mm; P =.012 at 5 mm). The use of an inverted master cone in cold lateral compaction may facilitate the apical placement of accessory cones, significantly increasing the volume of gutta-percha while reducing the volume of sealer in the apical root canal.

  20. The antimicrobial and antifungal efficacy of tetracycline-integrated gutta-percha

    Directory of Open Access Journals (Sweden)

    Bodrumlu Emre

    2008-01-01

    Full Text Available The purpose of this study was in vitro evaluation of the antimicrobial and antifungal efficacy of commercially available gutta-percha containing tetracycline on some potential endodontic pathogens. The test microorganisms were Enterococcus faecalis, Pseudomonas aeruginosa, Staphylococcus aureus, Porphyromonas endodontalis, and Candida albicans . Tetracycline-integrated gutta-percha (TGP cones, tetracycline disc, and conventional gutta-percha cones of the same size were placed on the inoculated plates. The plates were incubated at 37°C aerobically or anaerobically. Growth inhibition zones on each plate were inspected at 24, 48, and 72 h. Tetracycline disc and TGP cones inhibited all the tested bacterial strains, however the greatest antimicrobial effect was seen on S. aureus. Tetracycline disc and TGP seemed less effective on E. faecalis and P. aeruginosa. However, all tested treatments were unable to affect C. albicans . Based on the results of this study, it seems that TGP offers an antimicrobial advantage over conventional gutta-percha.

  1. [Thermoplasticized gutta percha in apexification].

    Science.gov (United States)

    Vicente Gómez, A; Miñana Laliga, R

    1990-01-01

    Filling the root canals in teeth after apexification is one useful clinical application of the thermoplasticized gutta-percha. We described 7 cases which Ultrafil was used in order to fill the canals. In all of them we made X-ray check-up.

  2. Comparative analysis of efficacy and cleaning ability of hand and rotary devices for gutta-percha removal in root canal retreatment: an in vitro study.

    Science.gov (United States)

    Reddy, Narender; Admala, Shilpa Reddy; Dinapadu, Sainath; Pasari, Srikanth; Reddy, Manoranjan P; Rao, M S Rama

    2013-07-01

    To evaluate the efficacy and cleaning ability of Hedstrom files, and ProTaper retreatment instruments in removing gutta-percha from root canals with and without xylene as solvent. Sixty extracted single rooted human teeth were selected and decoronated, straight access established working length determined 1 mm short of canal, chemomechanical preparation done and obturated with guttapercha and AH plus sealer. Samples were stored for 1 week in humidifier divided into four groups of 15 teeth each. • Group I: Hedstrom files without xylene. • Group II: Hedstrom files with xylene. • Group III: ProTaper retreatment instruments without xylene. • Group IV: ProTaper retreatment instruments with xylene. and the following criteria were assessed - Time taken for initial plunge of instrument into guttapercha. - Time taken for complete removal of gutta-percha to reach working length - Ability of H files and ProTaper retreatment files with/ without xylene to remove gutta-percha in coronal, middle and apical 1/3 of canal. The teeth were grooved in labiolingual cross section, observed under a steromicroscope and scored according to gutta-percha debris left in the canal. Results were evaluated using ANOVA test and multiple comparisons done using Scheffe test. The least time to reach working length was found with group IV followed by groups III, II and group I respectively. Also the fastest way to remove maximum gutta-percha was group IV followed by groups III, II, and I respectively with a statistically significant difference among all groups. Apical 1/3 has more amount of remaining gutta-percha debris than middle and coronal 1/3 in all groups. The amount of gutta-percha debris in apical 1/3 was least in group IV followed by groups III, II and I respectively. The better performance of ProTaper rotary instruments has been attributed to their special flute design which tends to pull gutta-percha coronally directing it toward orifice. Also the movements of engine driven

  3. Radiographic evaluation of the quality of root canal obturation of single-matched cone Gutta-percha root canal filling versus hot lateral technique

    Directory of Open Access Journals (Sweden)

    Randa Suleiman Obeidat

    2014-01-01

    Full Text Available Aim: The aim of this study is to evaluate radiographically the quality of root canal filling in mesiodistal and buccolingual view when comparing matched cone condensation and warm lateral Gutta-percha condensation using system B heating instrument in a low-heat warm lateral condensation technique in0 vitro. Materials and Methods: A total of 40 mandibular premolars with straight single canals were divided into two groups with 20 each. The root canals were shaped by hand file and Revo-S rotary files to size (25, 0.06 at the end point, then they filled by Gutta-percha cone and meta-seal sealer. In group A, a single matched cone technique was used to fill the root canals. In group B, a hot lateral condensation using system B instrument at 101°C was performed. Result: The result of this study showed no significant difference in density of Gutta-percha fill in apical and coronal two-third when comparing matched cone root canal filling and hot lateral technique (P > 0.05. The only significant difference (P < 0.05 was in matched cone between buccolingual and mesiodistal view in the coronal two-third. Conclusion: Within the limitation of this study, single matched cone technique has a good density in the apical one-third as that of the hot lateral technique so it may be used for filling narrow canals. In the coronal two-third of the root canal, single matched cone technique showed inferior density of root canal filling which can be improved by using accessory cones Gutta-percha in wide canal.

  4. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

    Science.gov (United States)

    Faus-Llácer, Vicente; Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-04-01

    The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.

  5. A comparative evaluation of gutta percha removal and extrusion of apical debris by rotary and hand files.

    Science.gov (United States)

    Chandrasekar; Ebenezar, A V Rajesh; Kumar, Mohan; Sivakumar, A

    2014-11-01

    The aim of this study was to evaluate the efficacy of Protaper retreatment files in comparison with RaCe, K3 and H-files for removal of gutta-percha and apically extruded debris using volumetric analysis. Forty extracted single rooted maxillary incisor teeth with straight canals and mature apices were selected for the study. After access cavity preparation, apical patency was confirmed with a size 10 K-file extending 1mm beyond the point at which it was first visible at the apical end. Working lengths were determined with the use of size 15 K-file. The canals were prepared in a step-back technique and the master apical file was size 30 for all teeth. 3% sodium hypochlorite was used as an irrigant after each instrumentation. Before final rinse, size 20 K-file was passed 1mm beyond the apex to remove any dentinal shaving plugs and maintain the apical patency. Then the canals were dried with paper points. The root canal was filled using standard gutta-percha points and zinc oxide eugenol sealer under lateral condensation technique. The teeth were then randomly divided into four groups of ten teeth each based on the instrument used for gutta percha removal. All the rotary instruments used in this study were rotated at 300rpm. The instruments used were: Group 1 - RaCe Files, Group 2 - ProTaper retreatment Files, Group 3 - K3 Files and Group 4 - H Files. The volume of the obturating material was calculated before and after removal using volumetric analysis with spiral CT. The removal efficacy with each instrument was calculated and statistically analysed. The results of the study show that the ProTaper retreatment files (Group 2) (97.4%) showed the highest efficiency in the removal of obturating material, which was followed by RaCe (95.74%), K3 (92.86%) and H files (90.14%) with the efficiency in the decreasing order. Similarly the mean apical extrusion in H files (0.000 ± 0.002) was significantly lower than all the rotary instruments. However, the difference among the

  6. Examination of gutta-percha cones for microbial contamination during chemical use

    Directory of Open Access Journals (Sweden)

    Guven Kayaoglu

    2009-06-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the degree of microbial contamination in packaged gutta-percha cones before and during use in clinical conditions. MATERIAL AND METHODS: Sealed packages of #15-40 gutta-percha cones were opened under aseptic laboratory conditions. Two gutta-percha cones from each size were randomly drawn and added to tubes containing glass beads and 750 µL of saline. The tubes were vortexed, serially diluted and samples of 250 µL were cultured on agar plates. The plates were incubated at 37ºC for 3 days and colonies were counted. The initially sampled packages were distributed to 12 final year dental students. The packages were collected at the end of the first and the third clinical practice days and sampled as described above. RESULTS: Baseline microbial counts did not exceed 3 CFU. At the end of the first and the third day, additional contamination was found in five and three of the packages, respectively. The ratio of contaminated packages at the first day and the third day was not significantly different (z-test; p > 0.05. The numbers of microorganisms cultured at the first day (8 ± 9.9 CFU and the third day (4.5 ± 8.3 CFU were not significantly different (Wilcoxon signed-rank test; p > 0.05. No significant correlation was found between the number of filled root canals and cultured microorganisms at either the first day (Spearman's rho; r = 0.481, p = 0.113 or the third day (r = -0.034, p = 0.917. CONCLUSIONS: Gutta-percha cones taken directly from manufacturer's sealed package harbored microorganisms. Clinical use of the packages has been found to be associated with additional contamination of the gutta-percha cones. The counts of cultured microorganisms did not correlate well with the number of filled root canals.

  7. Ex vivo evaluation of coronal and apical microbial leakage of root canal - Filled with gutta-percha or Resilon/Epiphany root canal filling material

    Directory of Open Access Journals (Sweden)

    de Almeida-Gomes Fabio

    2010-01-01

    Full Text Available Objective: This ex vivo study compared coronal and apical microleakage of root canals filled with Resilon/Epiphany (RE or gutta-percha/Grossman sealer (GP, using either lateral condensation (LC or System B (SB technique. Materials and Methods: Specimens in eight experimental groups were obturated using the following materials and techniques: Groups 1 and 3 - GP and LC; groups 2 and 4 - GP and SB; groups 5 and 7 - RE and LC; groups 6 and 8 - RE and SB. Apical and coronal leakages were tested using bacterial methods. For coronal analysis, the number of days required for complete contamination of the root canals was recorded according to observation of the brain heart infusion broth turbidity for 15 weeks. For apical analysis, the teeth were cleaved and the leakage was measured at 30 days. Data were collected for each sample and analyzed statistically with the Chi-square and ANOVA tests. Results: Leakage was found in all groups. The difference between filling materials, obturation techniques, and median time of leakage was not statistically significant for coronal ( P=0.847 and apical ( P=0.5789 leakages. Conclusion: There were no differences between the different filling materials (gutta-percha/Grossman sealer and Resilon/Epiphany and obturation techniques (lateral condensation and system B technique in coronal or apical leakages.

  8. FISHing for gutta-percha-adhered biofilms in purulent post-treatment apical periodontitis.

    Science.gov (United States)

    Zehnder, M; Rechenberg, D-K; Thurnheer, T; Lüthi-Schaller, H; Belibasakis, G N

    2017-06-01

    This study investigated the possibility of depicting individual taxa in clinically relevant biofilms using fluorescent in situ hybridization (FISH). Gutta-percha samples were collected from the apical aspect of root canals associated with a chronic apical abscess (test samples, n = 8). Corresponding control samples were obtained from previously filled root canals with apparently normal periapical tissues (n = 3). The transport medium was investigated for detached biofilm fragments using FISH staining and conventional epifluorescence microscopy. Gutta-percha samples were stained by multiplex FISH, and inspected using confocal laser scanning microscopy. FISH of the transport medium confirmed the presence of the main species formerly identified by conventional methods in post-treatment purulent endodontic infections, most prominently Fusobacterium spp., Bacteroidetes and Prevotellaceae. Treponemes were identified in five of eight cases associated with purulent infections, but Enterococcus faecalis and Staphylococcus spp. were not identified. The biofilms on gutta-percha from root canals associated with apical periodontitis showed dense aggregates of variable composition. Control samples contained few, if any, bacteria in the transport medium, and featured no biofilms on the respective gutta-percha specimens. The current study revealed some direct, visual in situ information on the nature of biofilms associated with purulent periapical infections in man. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Hermetizing ability of the new obturating material for root canals «Real Seal» with «Resilon» technology

    Directory of Open Access Journals (Sweden)

    Makedonova Y.A.

    2012-03-01

    Full Text Available Simple, reliable and predictable obturation of root canals side by side with their cleaning and forming is an essential part of the endodontic treatment. The aim of this research is investigation of obturation density of root canals. Canals filled by means of lateral condensation of the new obturative system «Real Seal/Resilon» and by means of traditional method of canals obturation with the help of gutta-percha and sealer АН-plus. The results of the research proved a ligher hermetizing ability of the new experimental material «Real Seal» in comparison with obturation by means of gutta-percha pins. The obtained data reflects an objective picture and can be applied as a unique quality monitoring obturation of root canals.

  10. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands

    International Nuclear Information System (INIS)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A.; Gurgel Filho, Eduardo; Teixeira, Fabricio B

    2001-01-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  11. Evaluation of apically extruded debris during removal of gutta-percha and ResilonTM using different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Pešić Dragana

    2018-01-01

    Full Text Available Background/Aim. Apical extrusion of material is considered as one of the very important factor for endodontic treatment success. Microorganisms, necrotic tissue, filling material and irrigants, which can be extruded apically during endodontic retreatment, may jeopardize the success of the therapy. The aim of this in vitro study was to quantitatively evaluate the amount of apically extruded debris during endodontic retreatment of teeth obturated with two different materials, using one hand and three rotary instrumentation techniques. Methods. Ninety-six extracted single-rooted teeth were endodontically treated and enlarged to size 40 using BioRaCe system, and then randomly divided into 8 groups of 12 specimens each. Half of the specimens were obturated with gutta-percha and AH Plus® sealer and another half with RealSeal SE system, using lateral condensation technique. Retreatment was performed using: Hedström files; ProFile rotary files; ProTaper Retreatment system and D-RaCe system. Apically extruded debris was collected in pre-weighed Eppendorf tubes and evaluated using an electronic microbalance. Data were analyzed statistically using t-test and analysis of variance. Results. In the AH Plus/gutta-percha group, all tested rotary instruments gave significantly less extruded debris compared with Hedström files (p < 0.05. In theRealSeal group, there was significant difference between DRaCe and Hedström instruments (p < 0.05. Conclusion. All retreatment techniques resulted in apical extrusion. DRaCe system produced significantly less extruded debris compared to hand files. No significant difference was found when comparing two instruments specially designed for retreatment: D-RaCe and ProTaper systems.

  12. The efficacy of two rotary NiTi instruments and H-files to remove gutta-percha from root canals

    Science.gov (United States)

    Akpınar, Kerem E.; Altunbaş, Demet

    2012-01-01

    Objective: The aim of this study was to evaluate the efficacy of R-Endo® and K3® rotary nickel-titanium instruments compared with manual instrumentation with H-files, with use of a solvent, for removal of gutta-percha during retreatment. Study design: Forty five freshly extracted human single-rooted teeth, each with one root canal, were instrumented with K-files and filled using cold lateral compaction of gutta-percha and AH 26® sealer. The teeth were randomly divided into three groups of 15 specimens each. Removal of gutta-percha was performed with the following devices and techniques: Group 1 (H-files), Group 2 (R-Endo®), and Group 3 (K3®). The specimens were rendered transparent for the evaluation of the area of remaining gutta-percha/sealer in buccolingual and mesiodistal directions. Statistical analysis as performed by using one-way ANOVA and Kruskal-Wallis tests (p=0.05). Results: All retreatment techniques used in this study left some filling material inside the root canal. Images in buccolingual and mesiodistal directions showed no significant differences between the groups (p>0.05). Conclusions: Under the experimental conditions, the remaining filling material after retreatment was similar for each group. Key words:Gutta-percha removal, K3®, NiTi, R-Endo®. PMID:22143729

  13. In-vitro evaluation of the effect of canal curvature on adaptation of gutta-percha in canals obturated with HEROfill system by CBCT

    International Nuclear Information System (INIS)

    Zarei, M.; Talati, A.; Mortazavi, M.; Zarch, H.H.; Javidi, M.; Bidokhty, H.A.

    2011-01-01

    A hermetic seal of the root canal space following canal preparation is important in endodontics. This study evaluated the effect of canal curve on adaptation of gutta-percha to dentinal walls of canals obturated using the Herofill system. For this in vitro study, 80 mesial roots of mature human first molars with length of 16 mm, curve between 5 deg and 45 deg, and no caries or resorption of the root surface were selected. A cone beam computed tomography system was used to evaluate the presence or absence of a gap in the samples. Photographs were taken in three sections: 2 mm above the curve, at the curve and 2 mm below the curve. The gap area was identified using Photoshop and AutoCAD software. Kruskal Wallis and Mann-Whitney tests were used to analyze the data mounted in a castcurve. There were significant differences between the two lateral condensation groups with various curves; roots with more curve had more gaps. When the Herofill and lateral condensation groups were compared without considering the sections and curve, there was a significant difference between these groups and the Herofill group had less gaps. The Herofill system is an alternative to the lateral condensation technique in severely curved canals. (author)

  14. Clinical analysis of heat gutta-percha vertical condensation in the treatment of pulpitis and periapical periodontitis

    Directory of Open Access Journals (Sweden)

    Li Fan

    2016-07-01

    Full Text Available Objective: To explore the clinical effect of heat gutta-percha vertical condensation in the treatment of pulpitis and periapical periodontitis. Methods: A total of 120 patients with pulpitis and periapical periodontitis who were admitted in our hospital from February, 2015 to February, 2016 were included in the study and randomized into the observation group and the control group. The patients in the observation group were given heat gutta-percha vertical condensation for root canal filling, while the patients in the control group were given cold gutta-percha lateral condensation root canal filling. The root canal filling was evaluated. The changes of GI, SBI, and PD before and after treatment were observed. Results: The correct filling, shorting filling, and extra filling in the observation group were significantly superior to those in the control group. After treatment, GI, SBI, and PD were significantly reduced, and the reduced degree in the observation group was significantly superior to that in the control group. Conclusions: Heat gutta-percha vertical condensation in the treatment of pulpitis and periapical periodontitis can significantly enhance the therapeutic effect, and improve GI, SBI, and PD, with a significant clinical effect; therefore, it deserves to be widely recommended.

  15. The Efficacy of the WaveOne Reciprocating File System versus the ProTaper Retreatment System in Endodontic Retreatment of Two Different Obturating Techniques.

    Science.gov (United States)

    Jorgensen, Ben; Williamson, Anne; Chu, Rene; Qian, Fang

    2017-06-01

    This ex vivo study aimed to evaluate the efficacy of retreating GuttaCore (Dentsply Tulsa Dental Specialties, Tulsa, OK) and warm vertically condensed gutta-percha in moderately curved canals with 2 different systems: ProTaper Universal Retreatment (Dentsply Tulsa Dental) and WaveOne (Dentsply Tulsa Dental). Eighty mesial roots of mandibular molars were used in this study. The mesiobuccal canals in each sample were prepared to length with the WaveOne Primary file (Dentsply Tulsa Dental). The canals were obturated with either a warm vertical approach or with GuttaCore and divided into 4 retreatment groups with the same mean root curvature: warm vertical retreated with ProTaper, warm vertical retreated with WaveOne, GuttaCore retreated with ProTaper, and GuttaCore retreated with WaveOne. The warm vertical groups were obturated using a continuous-wave technique of gutta-percha compaction, and the GuttaCore groups were obturated according to the manufacturer's instructions. After allowing sealer to set, each specimen was retreated with either the ProTaper Universal Retreatment files D1, D2, or D3 or with the WaveOne Primary file to the predetermined working length. The time taken to reach the working length was recorded. Instrument fatigue and failure were also evaluated. The post hoc 2-sample t tests showed that the overall mean total time taken to reach the working length for the warm vertical groups was significantly greater than that observed for the GuttaCore groups (mean = 87.11 vs 60.16 seconds, respectively), and the overall mean total time taken to reach the working length for WaveOne was significantly greater than that observed for ProTaper (99.09 vs 48.18 seconds, respectively). Two-way analysis of variance showed a significant main effect for both the type of experiment groups (F 1,76  = 15.32, P = .0002) and the type of retreatments (F 1,76  = 54.67, P file underwent more separations than the ProTaper files. The WaveOne Primary file underwent

  16. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    Directory of Open Access Journals (Sweden)

    Mary Kinue Nakamune Uezu

    2010-12-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. MATERIAL AND METHODS: The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. RESULTS: ProTaper Universal files were significantly faster (p=0.0011 than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. CONCLUSIONS: ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris.

  17. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands; Propriedades quimicas de cones de guta-percha: avaliacao de diferentes marcas comerciais

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A. [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Quimica Organica e Inorganica]. E-mail: juniorquim@yahoo.com.br; rpaula@dqoi.ufc.br; judith@dqoi.ufc.br; Gurgel Filho, Eduardo; Teixeira, Fabricio B [Universidade Estadual de Campinas, Piracicaba, SP (Brazil). Faculdade de Odontologia.Dept. de Odontologia Restauradora]. E-mail: gurgeleduardo@aol.com

    2001-07-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  18. In vitro evaluation of the contact angle formed between AH Plus, Hybrid Root Seal and mineral trioxide aggregate Plus sealer with dentin and gutta-percha.

    Science.gov (United States)

    Nikhil, Vineeta; Jaiswal, Shikha; Bajpai, Gauravi

    2018-01-01

    The purpose of this study was evaluation and comparison of the contact angle of new root canal sealers - Hybrid Root Seal, mineral trioxide aggregate (MTA) Plus, and the conventional AH Plus sealer with dentin and gutta-percha. Two groups (Group D - dentin and Group G - gutta-percha) of 18 samples each were further randomly divided into 3 subgroups based on the type of sealer used, that is, AH Plus, Hybrid Root Seal, and MTA Plus. Contact angle measurement device (Phoenix 300) was used to measure the contact angle of the sealers on both dentin and gutta-percha. The results thus obtained were analyzed using one-way analysis of variance and Student's t -test. MTA Plus recorded significantly higher values of contact angle on both the substrates, that is, dentin and gutta-percha when compared to AH Plus and Hybrid root canal sealer. The lowest value of contact angle in gutta-percha and dentin was shown by Hybrid root canal sealer and AH Plus, respectively. Both AH Plus and Hybrid Root Seal exhibited lower contact angle values, and hence, better wettability on both dentin and gutta-percha as compared to MTA Plus.

  19. Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones

    Directory of Open Access Journals (Sweden)

    Ana Carolina Rodrigues Danzi Salvia

    2011-02-01

    Full Text Available The aim of this study was to evaluate the effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones contaminated in vitro with Escherichia coli, Staphylococcus aureus, Streptococcus mutans, Candida albicans and Bacillus subtilus (in spore form. Two hundred and twenty-five gutta-percha cones were contaminated with standardized suspensions of each microorganism and incubated at 37°C for 24 h. The cones were divided into 10 experimental groups (n = 15, according to the microorganism tested and disinfection testing times. The disinfection procedure consisted of immersing each cone in a plastic tube containing the substance. The specimens remained in contact with the substance for 1 or 2.5 minutes. Afterwards, each cone was transferred to a 10% sodium thiosulphate solution (Na2S2O3 to neutralize the disinfectant. Microbial biofilms adhering to the cones were dispersed by agitation. Aliquots of 0.1 ml of the suspensions obtained were plated on Sabouraud dextrose agar, or brain and heart infusion agar, and incubated at 37°C for 24 h. The results were expressed in colony forming units (CFU/ml and the data were submitted to the Wilcoxon Signed Rank Test (level of significance at 0.05. A significant reduction was observed, after 1 minute of exposure, in the test solution for C. albicans (p = 0.0190, S. aureus (p = 0.0001, S. mutans (p = 0.0001, B. subtilis (p = 0.0001, and E. coli (p = 0.0001. After 2.5 minutes of exposure, 100% of the microbial inocula were eliminated. It was concluded that the 2% peracetic acid solution was effective against the biofilms of the tested microorganisms on gutta-percha cones at 1 minute of exposure.

  20. Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones.

    Science.gov (United States)

    Salvia, Ana Carolina Rodrigues Danzi; Teodoro, Guilherme Rodrigues; Balducci, Ivan; Koga-Ito, Cristiane Yumi; Oliveira, Simone Helena Gonçalves de

    2011-01-01

    The aim of this study was to evaluate the effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones contaminated in vitro with Escherichia coli, Staphylococcus aureus, Streptococcus mutans, Candida albicans and Bacillus subtilus (in spore form). Two hundred and twenty-five gutta-percha cones were contaminated with standardized suspensions of each microorganism and incubated at 37°C for 24 h. The cones were divided into 10 experimental groups (n = 15), according to the microorganism tested and disinfection testing times. The disinfection procedure consisted of immersing each cone in a plastic tube containing the substance. The specimens remained in contact with the substance for 1 or 2.5 minutes. Afterwards, each cone was transferred to a 10% sodium thiosulphate solution (Na(2)S(2)O(3)) to neutralize the disinfectant. Microbial biofilms adhering to the cones were dispersed by agitation. Aliquots of 0.1 ml of the suspensions obtained were plated on Sabouraud dextrose agar, or brain and heart infusion agar, and incubated at 37°C for 24 h. The results were expressed in colony forming units (CFU/ml) and the data were submitted to the Wilcoxon Signed Rank Test (level of significance at 0.05). A significant reduction was observed, after 1 minute of exposure, in the test solution for C. albicans (p = 0.0190), S. aureus (p = 0.0001), S. mutans (p = 0.0001), B. subtilis (p = 0.0001), and E. coli (p = 0.0001). After 2.5 minutes of exposure, 100% of the microbial inocula were eliminated. It was concluded that the 2% peracetic acid solution was effective against the biofilms of the tested microorganisms on gutta-percha cones at 1 minute of exposure.

  1. An Evaluation of GuttaFlow2 in Filling Artificial Internal Resorption Cavities: An in vitro Study.

    Science.gov (United States)

    Mohammad, Yara; Alafif, Hisham; Hajeer, Mohammad; Yassin, Oula

    2016-06-01

    Obturation of root canal with internal resorption represents a major challenge in Endodontics. In spite of that, usual obturation techniques are often employed without considering the best technique to solve this problem. The goal of this study was to investigate the ability of GuttaFlow2 in filling artificial internal resorption cavities. The study sample included 36 human upper central incisors that were prepared using Protaper system (F4). Internal resorption cavities were prepared by cutting each tooth at 7 mm from the apex and preparing hemispherical cavities on both the sides and then re-attaching them. The sample was randomly separated into three groups (n = 12 in each group). In the first group, thermal injection technique (Obtura II) was employed and served as the control group. In the second group, injection of cold free-flow obturation technique with a master cone (GF2-C) was employed, whereas in the third group injection of cold free-flow obturation without a master cone (GF2) was followed. The teeth were re-cut at the same level as before and examined under a stereomicroscope. Subsequently, the captured images were transferred to AutoCAD program to measure the percentage of total filling "TF," gutta-percha "G," sealer "S," and voids "V" out of the total surface of the cross sections. All materials showed high filling properties in terms of "total filling," ranging from 99.17% (for Obtura II) to 99.72% (for GF2-C). Regarding gutta-percha percentages of filling, they ranged from 83.15 to 83.93%, whereas those for the sealer ranged from 5.71 to 15.24%. GuttaFlow2 group with a master cone appeared to give the best results despite the insignificant differences among the three groups. The GuttaFlow2 with a master cone technique seemed to be a promising filling material and gave results similar to those observed with Obtura II. It is recommended for use to obturate internal resorption cavities in clinical practice due to its good adaptability to root canal

  2. Endodontic retreatment of dens invaginatus presenting with gutta-percha overfilling at the attached gingiva and chronic apical periodontitis: unusual clinical report.

    Science.gov (United States)

    Robazza, Carlos Roberto Colombo; Alves e Motta, Julio Cesar; de Carli, Marina Lara; de Oliveira Pedreira, Fernanda Rafaelly; Hanemann, Joao Adolfo Costa

    2013-05-01

    This work describes the retreatment of an unusual case of dens invaginatus with gutta-percha overfilling at the gingival mucosa and chronic apical periodontitis in a 34-year-old woman. Initial periapical radiograph showed the presence of type II dens invaginatus with poor quality obturation, root perforation and chronic apical periodontitis of tooth 22. Dens invaginatus is a tooth malformation caused by infolding of the dental papilla during tooth development. This anomaly has been associated with increased prevalence of pulpal and periapical diseases. Conventional endodontic retreatment was performed using rotary files and calcium hydroxide paste as intracanal dressing. After 7 days, root canal was filled with guttapercha points and Sealapex® sealer. Obturation was radiographically followed and, after 3 years, absence of fistula and periapical radiolucency was observed, thus conventional endodontic therapy proved to be successful. Conventional endodontic retreatment of type II dens invaginatus has been successful for a 3-year period, showing a better treatment alternative. Conservative endodontic retreatment of dens invaginatus should be considered to promote periapical healing with complete reconstitution of bone and periodontal ligament regeneration without signs of recurrence over a period of 3 years. Moreover, it preserves the entire tooth.

  3. Efficacy of ProTaper retreatment system in root canals filled with gutta-percha and two endodontic sealers.

    Science.gov (United States)

    Só, Marcus Vinícius Reis; Saran, Caroline; Magro, Miriam Lago; Vier-Pelisser, Fabiana Vieira; Munhoz, Marcelo

    2008-10-01

    This study evaluated the efficacy of ProTaper Universal rotary retreatment system and hand files for filling material removal during retreatment and the influence of sealer type on the presence of filling debris in the reinstrumented canals. The canals of 60 palatal roots of first molars were obturated with gutta-percha and either a zinc oxide-eugenol-based or a resin-based sealer and reinstrumented: G1, EndoFill/hand files; G2, AH Plus/hand files; G3, EndoFill/ProTaper; G4, AH Plus/ProTaper. Roots were cleaved and examined with an optical microscope, and the amount of filling debris on canal walls was analyzed on digitized images. There was no significant difference (P > .05) among the root canal thirds within each group. G3 presented significantly more filling debris than G1 in the cervical third (P = .04). In the middle third, G2/G3/G4 showed more debris than G1 (P = .03). The techniques were similar (P = .64) in the apical third. All groups presented filling debris in the 3 canal thirds after reinstrumentation.

  4. Efficacy of peracetic acid in rapid disinfection of Resilon and gutta-percha cones compared with sodium hypochlorite, chlorhexidine, and povidone-iodine.

    Science.gov (United States)

    Subha, N; Prabhakar, V; Koshy, Minu; Abinaya, K; Prabu, M; Thangavelu, Lavanya

    2013-10-01

    The aim of this investigation was to compare the effectiveness of 3% sodium hypochlorite (NaOCl), 2% chlorhexidine, 1% peracetic acid, and 10% povidone-iodine in the rapid disinfection of Resilon (Pentron Clinical Technologies, LLC, Wallingford, CT) and gutta-percha cones contaminated with Enterococcus faecalis and Bacillus subtilis. Two hundred fifty-six samples consisting of 128 gutta-percha cones and 128 Resilon cones were used in this study. The materials were tested for disinfection according to the type of solution (3% NaOCl, 2% chlorhexidine, 1% peracetic acid, or 10% povidone-iodine), the time of exposure to each solution (1 or 5 minutes), and the type of microorganisms (E. faecalis or B. subtilis). Subsequent to the disinfection, samples were placed in test tubes containing 10 mL Mueller-Hinton broth and incubated at 37°C for 7 days. All test tubes were observed at 24-hour intervals and visually checked for turbidity, signifying microbial growth. In this study, 1% peracetic acid showed the best results for both 1 minute and 5 minutes of disinfection, 2% chlorhexidine showed the second best results although it was statistically at par with peracetic acid, and 3% hypochlorite ranked third in disinfection; this was statistically significant when compared with peracetic acid and chlorhexidine. Disinfection by povidone-iodine was the least within all the groups for both contact times although disinfection for 5 minutes showed better results than disinfection for 1 minute for gutta-percha. The outcome of this study confirmed the efficacy of 1% peracetic acid and 2% chlorhexidine in the rapid disinfection of both Resilon and gutta-percha. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Efficacy of Reciproc(®) and Profile(®) Instruments in the Removal of Gutta-Percha from Straight and Curved Root Canals ex Vivo.

    Science.gov (United States)

    Marfisi, Karem; Mercadé, Montserrat; Plotino, Gianluca; Clavel, Tatiana; Duran-Sindreu, Fernando; Roig, Miguel

    2015-01-01

    To compare the efficacy of Reciproc(®) (VDW GmbH) and ProFile(®) (Dentsply Maillefer) instruments at removing gutta-percha from straight and curved root canals ex vivo filled using the cold lateral condensation and GuttaMaster(®) (VDW GmbH) techniques. Forty mesial roots of mandibular molars with two curved canals and 80 single-rooted teeth with straight root canals, a total of 160 root canals, were randomly assigned to eight groups (canals per group = 20) according to filling technique, retreatment instrument and root canal curvature as follows: Group I, cold lateral condensation/ProFile(®)/straight; Group II, cold lateral condensation/ProFile(®)/curved; Group III, cold lateral condensation/Reciproc(®)/straight; Group IV, cold lateral condensation/Reciproc(®)/curved; Group V, GuttaMaster(®)/ProFile(®)/straight; Group VI, GuttaMaster(®)/ProFile(®)/curved; Group VII, GuttaMaster(®)/Reciproc(®)/straight; and Group VIII, GuttaMaster(®)/Reciproc(®)/curved. The following data were recorded: procedural errors, retreatment duration and canal wall cleanliness. Means and standard deviations were calculated and analysed using the Kruskal-Wallis test, one-way analysis of variance and Tukey's test (P straight (P = 0.0001) and curved (P = 0.0003) root canals. Reciproc(®) were statistically more effective than ProFile(®) instruments in removing GuttaMaster(®) from straight root canals (P = 0.021). Regardless of filling technique or retreatment instrument, gutta-percha was removed more rapidly from curved than from straight root canals (P = 0.0001). Neither system completely removed filling material from the root canals. Compared with ProFile(®) instruments, Reciproc(®) instruments removed GuttaMaster(®) filling material from straight and curved root canals more rapidly.

  6. Application of microcomputed tomography for quantitative analysis of dental root canal obturations

    Directory of Open Access Journals (Sweden)

    Anna Kierklo

    2014-03-01

    Full Text Available Introduction: The aim of the study was to apply microcomputed tomography to quantitative evaluation of voids and to test any specific location of voids in tooth’s root canal obturations. Materials and Methods: Twenty root canals were prepared and obturated with gutta-percha and Tubli-Seal sealer using the thermoplastic compaction method (System B + Obtura II. Roots were scanned and three-dimensional visualization was obtained. The volume and Feret’s diameter of I-voids (at the filling/dentine interface and S-voids (surrounded by filling material were measured.Results: The results revealed that none of the scanned root canal fillings were void-free. For I-voids, the volume fraction was significantly larger, but their number was lower (P = 0.0007, than for S-voids. Both types of voids occurred in characteristic regions (P < 0.001. I-voids occurred mainly in the apical third, while S-voids in the coronal third of the canal filling.Conclusions: Within the limitations of this study, our results indicate that microtomography, with proposed semi-automatic algorithm, is a useful tools for three-dimensional quantitative evaluation of dental root canal fillings. In canals filled with thermoplastic gutta-percha and Tubli-Seal, voids at the interface between the filling and canal dentine deserve special attention due to of their periapical location, which might promote apical microleakage. Further studies might help to elucidate the clinical relevance of these results.

  7. Effect of customization of master gutta-percha cone on apical control of root filling using different techniques: an ex vivo study.

    Science.gov (United States)

    van Zyl, S P; Gulabivala, K; Ng, Y-L

    2005-09-01

    (i) To compare the prevalence of extrusion of root filling material when placed using different root filling techniques, with or without customization of the master gutta-percha (GP) cone; and (ii) to investigate the effects of some factors influencing root filling extrusion and presence of voids. A total of 180 roots were selected, prepared and randomly allocated to three groups. Five general dental practitioners performed the root fillings; each filled one group of roots (n = 60) using each of three techniques; 'cold lateral compaction' (n = 20), 'warm vertical compaction' (n = 20) and 'continuous-wave' (n = 20) techniques. For each obturation technique, the master GP cone was customized using chloroform in 10 samples. Two groups of the roots were recycled to allow all five operators to fulfill their remit. Two observers, blind to operator and obturation technique, examined the radiographs (master apical file, post-obturation) to determine the presence of root filling extrusion and voids within the apical 5 mm, independently. Root filling extrusion was also confirmed by direct inspection of the root apex after obturation. The data were analysed using logistic regression models. A total of 300 root fillings were performed; nine were excluded from the analysis. Most of the root fillings (80%, n = 233) were placed within 0.5 mm of the working length; only 20% (n = 58) were placed >0.5 mm beyond the working length. The odds of prevalence of extrusion (>0.5 mm) were significantly reduced by about 50% when cold lateral compaction or customization of GP were used. One operator produced 2.5 times more extruded root fillings than others. Curvature & length of root canal, apical size of prepared canal, as well as operator's preferred obturation technique had no significant influence on the prevalence of extrusion. Customization of GP was the sole factor to significantly reduce the prevalence of voids within the apical 5 mm of working length. Root filling extrusion was

  8. Three-dimensional evaluation of effectiveness of hand and rotary instrumentation for retreatment of canals filled with different materials.

    Science.gov (United States)

    Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick

    2008-11-01

    The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.

  9. Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files

    Science.gov (United States)

    Bajaj, Nitika; Monga, Prashant; Mahajan, Pardeep

    2017-01-01

    Objectives: To compare the dimensions of gutta-percha (GP) cones of ProTaper Next (25/0.06) and WaveOne (25/0.08) in relation to their corresponding instruments of the same dimension, respectively. Materials and Methods: Two groups of GP cones were made with 25 cones in each group. Group 1 consisted of 25 GP cones # 25/0.06 (ProTaper Next). Group 2 consisted of 25 GP cones # 25/0.08 (WaveOne). Measurements were done at D1 (1 mm short of the tip), D3 (3 mm short of the tip), and D11 (11 mm short of the tip) for GP cones of both groups and were compared with their corresponding instruments. Results: Group 1 (ProTaper) 25/.06 GP points showed greater diameters than those of the corresponding instrument, which was statistically significant. Group 2 (WaveOne) 25/0.08 GP points showed greater diameters than those of the corresponding instrument which was statistically significant whereas it was nonsignificant at level D1. Conclusion: Diameters of both ProTaper Next and WaveOne GP cones were greater than their corresponding instruments. Hence, there are chances of under obturation with both systems. PMID:28729793

  10. New endodontic obturation systems and their interfacial bond strength with intraradicular dentine - ex vivo studies.

    Science.gov (United States)

    Pawińska, M; Kierklo, A; Tokajuk, G; Sidun, J

    2011-01-01

    To comparatively evaluate adhesive properties of selected root canal fillings through the measurement of the material-dentine interfacial bond strength. Fifty extracted single-rooted human teeth with one canal each were prepared using Hero instruments to size 30.04. Teeth were divided into four subgroups depending on the root canal filling material and the method of obturation: Resilon/Epiphany - a thermoplastic method (IA), Resilon/Epiphany - a matching single-point method (IB), gutta-percha/Roeko Seal Automix - a thermoplastic method (IIA) and gutta-percha/Roeko Seal Automix - a matching single-point method (IIB). The obturated roots were cut perpendicular to the long axis to create 1.7 mm thick slices. The bond strength was measured for each test slice with push -out testing machine. The highest push-out bond strength was registered in subgroup IB (3.98 ± 1.33 MPa). Significantly lower bond strength was observed in subgroups IA (0.50 ± 0.24 MPa), IIA (0.33 ± 0.18 MPa) and IIB (0.08 ± 0.03 MPa) (pmaterial-dentine interfacial bond strength values were observed between IA and IIA, IA and IIB, IIA and IIB subgroups (p > 0.05). The push-out bond strength of the material-dentine interface was dependent on the type of material used and the root canal filling technique. The R/E system exhibited better adhesion ability to intraradicular dentine than G/RSA. The highest bond strength was observed for Resilon/Epiphany introduced with the single-cone technique.

  11. Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre.

    Science.gov (United States)

    Mirmohammadi, Hesam; Sitarz, Monika; Shemesh, Hagay

    2018-01-01

    Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of their corresponding files at different levels using laser micrometre. Twenty files and corresponding GP master cones of Reciproc R40 (40/0.06) (VDW, Munich, Germany), WaveOne Large(40/0.08)(Dentsply Maillefer, Ballaigues, Switzerland), ProTaper F3 (30/0.09) (Dentsply Maillefer, Ballaigues, Switzerland), and Mtwo 40/0.06 (VDW, Munich, Germany) were examined using laser micrometre (LSM 6000 by Mitutoyo, Japan) with accuracy of 1 nm to establish their actual diameter at D 0 , D 1 , D 3 and D 6 . The data was analysed using the independent t -test. The differences were considered at 0.05. The diameter of GP master cones was significantly larger than that of the corresponding files at all levels in all brands. ProTaper GP diameter was closest to the file diameter at D1 (GP=0.35, File=0.35 mm), and D3 (GP=0.48, File=0.49). Within the same manufacturer, GP cone diameters do not match the diameters of their corresponding files. Clinicians are advised to use a GP gauge to cut the tip so as to appropriate the diameter from a smaller sized GP cone.

  12. Fracture resistance of endodontically treated roots filled with resilon and guttapercha - A comparative in-vitro study

    Directory of Open Access Journals (Sweden)

    Rajesh R Shetty

    2009-01-01

    Full Text Available Aims and objectives: The purpose of this study was to evaluate and compare in vitro the fracture resistance of endodontically treated roots filled with Resilon and Gutta-percha. Methodology: Eighty extracted single canal teeth were selected and randomly assigned to five groups of sixteen teeth each. Teeth were sectioned using a diamond disc so as to obtain a root length of 14±1 mm. Roots were instrumented using .04 taper Profile rotary system to an apical size of 40 and obturated using .04 taper single cone (size 40 as follows: Group 1: Resilon .04 taper cone and Epiphany Self etching sealer, Group 2: .04 taper gutta-percha cone and AH Plus sealer ,Group 3: .04 taper gutta-percha cone and Roeko Seal Automix sealer, Group 4: .04 taper gutta-percha cone and Zinc oxide Eugenol sealer , Group 5: .04 taper gutta-percha cone without the use of a sealer. Following obturation, teeth were mounted in Poly Vinyl Chloride jigs using self cure acrylic resin such that 9mm of the root remained exposed. Fracture resistance testing was done using Instron testing machine using a vertical load applied perpendicular to the root surface. Statistical analysis was done using ANOVA, Tukey HSD and Student′s ′t′ test. Results: Very highly significant difference was observed between the groups (P=.001. Resilon with Epiphany group demonstrated highest mean fracture resistance value and gutta-percha without sealer displayed the least, comparative results were highly significant. Resilon compared to gutta-percha with Roeko Seal Automix (P=.037 and Zinc Oxide Eugenolsealers (P=.029 showed statistically significant difference. AH plus group showed significantly higher value compared to gutta-percha without sealer. Conclusions: Filling the root canals with Resilon increased the in vitro fracture resistance of endodontically treated roots compared to standard gutta-percha techniques. Adhesive sealers are more beneficial in increasing the fracture resistance of

  13. In vitro evaluation of the effectiveness of ProTaper universal rotary retreatment system for gutta-percha removal with or without a solvent.

    Science.gov (United States)

    Takahashi, Cristiane Midori; Cunha, Rodrigo Sanches; de Martin, Alexandre Sigrist; Fontana, Carlos Eduardo; Silveira, Cláudia Fernandes M; da Silveira Bueno, Carlos Eduardo

    2009-11-01

    Effective removal of gutta-percha in endodontic retreatment is a significant factor to ensure a favorable outcome from failed procedures. The purpose of this study was to evaluate the efficacy of a nickel-titanium rotary instrument system with or without a solvent versus stainless steel hand files for gutta-percha removal. Forty extracted human maxillary anterior teeth were prepared and filled. They were divided into 4 groups: Gates-Glidden and K-files, Gates-Glidden and K-files with chloroform, ProTaper Universal rotary retreatment system, and ProTaper Universal rotary retreatment system with chloroform. The operating time was recorded. The teeth were longitudinally sectioned and photographed. The images were analyzed and the filling remnants were quantified by using the IMAGE TOOL software. With Kruskall-Wallis test, statistical analysis showed that there was no significant difference between the techniques in regard to the amount of the endodontic filling remnants (P ProTaper Universal rotary retreatment system was faster than the hand files (P ProTaper Universal rotary retreatment system without chloroform was faster.

  14. Accuracy of two root canal length measurement devices integrated into rotary endodontic motors when removing gutta-percha from root-filled teeth.

    Science.gov (United States)

    Uzun, O; Topuz, O; Tinaz, C; Nekoofar, M H; Dummer, P M H

    2008-09-01

    To evaluate ex vivo the accuracy of the integrated electronic root canal length measurement devices within TCM Endo V and Tri Auto ZX motors whilst removing gutta-percha and sealer from filled root canals. Forty freshly extracted maxillary and mandibular incisor teeth with mature apices were selected. Following access cavity preparation, the length of the root canals were measured visually 0.5 mm short of the major foramen (TL). The canals were prepared using the HERO 642 system and then filled with gutta-percha and AH26 sealer using a lateral compaction technique. After 7 days the coronal temporary filling was removed and the roots mounted in an alginate experimental model. The roots were then randomly divided in two groups. The access cavities were filled with chloroform to soften the gutta-percha and allow its penetration using the Tri Auto ZX and the TCM Endo V devices in groups 1 and 2, respectively. The 'automatic apical reverse function' (ARL) of both devices was set to start at the 0.5 setting and the rotary instrument inserted inside the root canal until a beeping sound was heard and the rotation of the file stopped automatically. Once the auto reverse function had been initiated, the foot pedal of the motor was inactivated and the rubber stop placed against the reference point. The distance between the file tip and rubber stop was measured using a digital calliper to 0.01 mm accuracy (ARL). Then, a size 20, 0.02 taper instrument was attached to each device and inserted into the root canals without rotary motion until the integrated ERCLMDs positioned the instrument tips at the 0.5 setting as suggested by the devices. This length was again measured using a digital calliper (EL). The Mann-Whitney U-test was used to investigate statistical differences between the true canal length and those indicated by the two devices when used in 'automatic ARL and when inserted passively (EL). In the presence of gutta-percha, sealer and chloroform, the auto

  15. Evaluation of resistance of teeth subjected to fracture after endodontic treatment using different root canal sealers: An in vitro study

    Directory of Open Access Journals (Sweden)

    S S Bhat

    2012-01-01

    Full Text Available Aims: The aim of this study was to compare the ex-vivo effects of different root canal sealers on the fracture resistance of endodontically treated teeth. Materials and Methods: Seventy-five freshly extracted human mandibular premolars were used for the study. The length was standardized to 14 mm and all the teeth were biomechanically prepared and divided into five different groups based on the type of root canal sealers used. Group I:- Roeko seal + gutta percha, Group II: AH plus ® root canal sealer + gutta percha, Group III: PULPDENT root canal sealer + gutta percha, Group IV: Zinc oxide-eugenol sealer + gutta percha, Group V: Control (unobturated teeth. The teeth were embedded in acrylic resin blocks and compressive strengths were measured using universal testing machine (Instron. Statistical Analysis Used: One-way ANOVA, unpaired t- test Results: Data obtained were statistically evaluated using one-way ANOVA and unpaired t-test. All groups showed a statistically significant result (P < 0.05. Teeth obturated with Group I and Group II showed higher resistance to fracture than teeth obturated with other three Groups. It was seen that the teeth obturated with group III showed a better fracture resistance than Group IV and there was no statistical significance found between Group and Group V. Conclusions: From this study, it has been concluded that both the resin based sealers that were used in this study were equally effective compared to that of the zinc oxide-based sealers and the control group. However, no significant results were obtained when the comparison was made between zinc oxide-eugenol and gutta-percha and the control group.

  16. Spiral computed tomography assessment of the efficacy of different rotary versus hand retreatment system

    OpenAIRE

    Neelam Mittal; Jyoti Jain

    2014-01-01

    Aims: The purpose of this study was to evaluate the efficacy of nickel-titanium rotary retreatment systems versus stainless steel hand retreatment system with or without solvent for gutta-percha removal during retreatment. Materials and Methods: Sixty extracted human mandibular molar teeth with single canal in a distal root was prepared with ProTaper rotary nickel-titanium files and obturated with gutta-percha and sealer. The teeth were randomly divided into six groups of 10 specimens in ...

  17. Efficacy of two rotary retreatment systems in removing Gutta-percha and sealer during endodontic retreatment with or without solvent: A comparative in vitro study.

    Science.gov (United States)

    Bhagavaldas, Moushmi Chalakkarayil; Diwan, Abhinav; Kusumvalli, S; Pasha, Shiraz; Devale, Madhuri; Chava, Deepak Chowdary

    2017-01-01

    The aim of this in vitro study was to compare the efficacy of two retreatment rotary systems in the removal of Gutta-percha (GP) and sealer from the root canal walls with or without solvent. Forty-eight extracted human mandibular first premolars were prepared and obturated with GP and AH Plus sealer. Samples were then randomly divided into four groups. Group I was retreated with MtwoR rotary system without solvent, Group II was retreated with MtwoR rotary system with Endosolv R as the solvent, Group III with D-RaCe rotary system without solvent, and Group IV with D-RaCe rotary system and Endosolv R solvent. The cleanliness of canal walls was determined by stereomicroscope (×20) and AutoCAD software. Kruskal-Wallis test and Mann-Whitney U-test were used to compare the data. Results showed that none of the retreatment systems used in this study was able to completely remove the root canal filling material. D-RaCe with or without solvent showed significantly ( P > 0.05) less filling material at all levels compared to MtwoR with/without solvent. Within the limitation of the current study, D-RaCe rotary retreatment system is more effective in removing filling material from root canal walls when compared to MtwoR rotary retreatment system.

  18. Comparative evaluation of tensile strength of Gutta-percha cones with a herbal disinfectant.

    Science.gov (United States)

    Mahali, Raghunandhan Raju; Dola, Binoy; Tanikonda, Rambabu; Peddireddi, Suresh

    2015-01-01

    To evaluate and compare the tensile strength values and influence of taper on the tensile strength of Gutta-percha (GP) cones after disinfection with sodium hypochlorite (SH) and Aloe vera gel (AV). Sixty GP cones of size 110, 2% taper, 60 GP cones F3 ProTaper, and 60 GP of size 30, 6% taper were obtained from sealed packs as three different groups. Experimental groups were disinfected with 5.25% SH and 90% AV gel except the control group. Tensile strengths of GP were measured using the universal testing machine. The mean tensile strength values for Group IA, IIA and IIIA are 11.8 MPa, 8.69 MPa, and 9.24 MPa, respectively. Results were subjected to statistical analysis one-way analysis of variance test and Tukey post-hoc test. 5.25% SH solutions decreased the tensile strength of GP cones whereas with 90% AV gel it was not significantly altered. Ninety percent Aloe vera gel as a disinfectant does not alter the tensile strength of GP cones.

  19. Evaluation of Different Dentin Bonding Agents Accompanied with Composite Coronal Barrier

    Directory of Open Access Journals (Sweden)

    Zahed Mohammadi

    2015-06-01

    Full Text Available Introduction: The purpose of this study was to evaluate the sealing ability of dentin bonding agents in root canals obturated with gutta-percha and MTA. Methods: Forty-five single rooted human premolar teeth were decoronated so that remaining root portions were 12 mm in length. The samples were divided randomly into three experimental (n=13 and two control groups (n=3. All teeth were instrumented up to #40 K-file using step-back technique. The roots were obturated with gutta-percha/AH26 and MTA for 5 and 3 mm, respectively. Excite, Clearfil SE Bond, and iBond were applied for experimental groups and then 2mm was filled with composite Filtek Z250. The roots in the controls were merely instrumented and obturated. Two coats of nail varnish were applied on the surface of the teeth in the experimental and positive groups, except 2 mm around the apical foramen and coronal surfaces. In the negative control, the surfaces were completely covered by two layers of nail varnish. After thermocycling, the roots mounted in plastic caps of tubes containing BHI medium and inoculated coronally with Enterococcus faecalis. The data were statistically analyzed using Fisher's exact and Kaplan-Meier survival Analysis. Results: There were no statistically significant differences between three experimental groups regarding the leakage rate (P=0.738. Conclusion: Within the limitations of this study, it was observed that the adhesive systems in alliance with gutta-percha and MTA obturation could not entirely

  20. Evaluation of antimicrobial efficacy of Aloe vera and its effectiveness in decontaminating gutta percha cones.

    Science.gov (United States)

    Athiban, Prakash P; Borthakur, Bikash Jyoti; Ganesan, S; Swathika, B

    2012-07-01

    The aim of this study was to evaluate the antimicrobial efficacy of Aloe vera and to determine its effectiveness in decontaminating gutta percha cones. A concentrated extract of Aloe vera was used to check for the antimicrobial efficacy using the agar well diffusion method. Presence of zones' of diffusion was identified against three common GP contaminants namely, E.coli, E.faecalis and Staph. aureus. New GP Cones, freshly taken out of the packet were then decontaminated for 1minute using Aloe vera gel and then placed in thioglycolate broth to check for the presence of turbidity. The zones of inhibition on the agar plate were measured as 24mm,21mm and 24mm respectively. The broth remained clear even after 48 hours of incubation. We conclude that Aloe vera is indeed effective as a GP decontaminant and it holds a promising future as a medium for storage of GP cones.

  1. ANTIMICROBIAL AND STRUCTURAL EFFECTS OF DIFFERENT IRRIGATION SOLUTIONS ON GUTTA-PERCHA CONES

    Directory of Open Access Journals (Sweden)

    Sevinç Aktemur Türker

    2015-01-01

    Full Text Available Purpose: To evaluate the alterations on the surface of gutta-percha cones (GPCs on exposure to the different irrigation solutions and their possible antibacterial effect against Enterococcus faecalis. (E. faecalis Materials and Methods: Disinfection ability of different solutions (5.25% sodium hypochlorite, 2% chlorhexidine, 1% peracetic acid, and QMix were tested with 96 GPCs and the time of exposure to each solution was 5 and10 minutes, respectively. GPCs used in this study were contaminated with E.faecalis. After disinfection, GPCs were placed in tubes containing the medium and incubated at 37˚C for 7 days. All tubes were visually checked for turbidity at 24-hour intervals. About 92 new GPCs were analyzed by means of SEM/EDS to assess the topography and chemical elements present on their surface. The data generated was analyzed using Pearson chi-square test, p0.05. SEM/EDS analyses showed no alteration in the superficial features of GPCs after treating with various irrigation solutions. Conclusion: QMix was found to be an effective agent for rapid disinfection of GPCs as well-known irrigation solutions. Irrigation solutions were found to have sterilized the GPCs after both 5 and 10 minutes of exposure.

  2. Physicochemical Properties of Calcium Phosphate Based Coating on Gutta-Percha Root Canal Filling

    Directory of Open Access Journals (Sweden)

    Afaf Al-Haddad

    2015-01-01

    Full Text Available Dental Gutta-percha (GP is a polymer based standard root canal filling material that has been widely used in dentistry. However, it has an inadequate sealing ability and adhesion to root dentin. The aim of this study is to coat GP with a bioactive material to enhance its sealing ability and adhesion to the root sealer and subsequently to the root dentin. The choice of coating method is limited by the nature of GP as it requires a technique that is not governed by high temperatures or uses organic solvents. In this study, biomimetic coating technique using 1.5 Tas-simulated body fluids (SBF was employed to coat the treated GP cones. The coated samples were characterized using Fourier transform infrared spectroscopy (FTIR, X-ray Diffraction (XRD, and field emission scanning electron microscope (FESEM. The presence of hydroxyl, carbonate, and phosphate groups was detected by FTIR while the formation of hydroxyapatite (HA/calcium phosphate was confirmed with XRD. FESEM revealed uniform, thin, and crystalline HA calcium phosphate coating. The adhesion of the coating to the GP substrate was assessed with microscratch technique. It was viable with cohesive failure mode. In conclusion, Tas-SBF is able to coat pretreated GP cones with a crystalline apatitic calcium phosphate layer.

  3. Successful nonsurgical endodontic outcome of a severely affected permanent maxillary canine with dens invaginatus Oehlers type 3.

    Science.gov (United States)

    Brooks, John K; Ribera, Michael J

    2014-10-01

    The morphogenic complexities of dens invaginatus (DI) Oehlers type 3 in maxillary canines offer significant endodontic challenges. A case report is provided of a 14-year-old female patient who presented with an anomalous-looking permanent maxillary canine associated with a sinus tract. Pulp testing revealed a normal response on the distal aspect of the tooth, whereas the mesial segment tested nonresponsive. A radiolucent lesion was seen on the mesiolateral radicular area adjacent to the severely distended pulp chamber. A gutta-percha point inserted into the sinus tract traced to this same region. The diagnosis was normal pulp coincident with DI Oehlers type 3 with pulp necrosis and chronic apical abscess. Despite a concerted effort to limit the root canal therapy to only the necrotic canal, its proximity to the normal canal obviated this possibility, entailing endodontic treatment of the entire root canal system. The necrotic pulp space was subjected to sustained irrigation with 5.25% sodium hypochlorite and then completed with 17% ethylenediaminetetraacetic acid. A bolus of gutta-percha was used to create an apical barrier, and then the remainder of the enlarged pulp space was obturated with injectable thermoplasticized gutta-percha. At a 4.5-year recall, there was no clinical and radiographic evidence of infection. Endodontic success was accomplished with meticulous efforts of disinfection. Thermoplasticized gutta-percha can offer utility for obturation of anatomically complicated pulp spaces. The use of the dental operating microscope is an invaluable aid for discernment of the intricacies of teeth affected with DI type 3 variant and can enhance clinical outcomes. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. [Nonsurgical retreatment of lateral radiopacity after surgical treatment].

    Science.gov (United States)

    Arias de Luxan, A

    1990-01-01

    A case report is presented of an upper central incisor with incomplete endodontic procedure evidencing a radiolucent image that was treated by apicoectomy and retroamalgam. A year later the periapical lesion had healed completely but a new lateral radiolucency is observed. A reentry of the canal is performed eliminating the old obturating material, biomechanical preparation and obturation with sealer and thermo gutta-percha. The lesion was cured in nine months.

  5. Evaluation of the Sealing Ability of Three Obturation Techniques Using a Glucose Leakage Test

    Directory of Open Access Journals (Sweden)

    Katarzyna Olczak

    2017-01-01

    Full Text Available The aim of this study was to evaluate the sealing ability of three different canal filling techniques. Sixty-four roots of extracted human maxillary anterior teeth were prepared using ProTaper® rotary instruments. The specimens were then randomly divided into 3 experimental groups (n=16 and 2 control groups (n=8. The root canals were filled using cold lateral compaction (CLC group, continuous wave condensation technique using the Elements Obturation Unit® (EOU group, and ProTaper obturators (PT group. For the negative control group, 8 roots were filled using lateral compaction as in the CLC group, and the teeth were covered twice with a layer of nail varnish (NCG group. Another 8 roots were filled using lateral compaction, but without sealer, and these were used as the positive control (PCG group. A glucose leakage model was used for quantitative evaluation of microleakage for 24 hours and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12 weeks. No significant difference in the cumulative amount of leakage was found between the three experimental groups at all observation times. The lateral condensation of cold gutta-percha can guarantee a similar seal of canal fillings as can be achieved by using thermal methods, in the round canals.

  6. "In vitro" evaluation of the apical sealing of root canals obturated with different techniques Avaliação "in vitro" do selamento apical dos canais radiculares em função de diferentes técnicas de obturação

    Directory of Open Access Journals (Sweden)

    Viviane Haiub Brosco

    2003-09-01

    Full Text Available The purpose of this study was to compare the apical sealing of root canals obturated with different techniques. One hundred-six human mandibular incisors were submitted to instrumentation by means of the step-back technique. After instrumentation, one hundred teeth received an impermeable coating on the external surfaces of the crown and root (except for the area nearby the apical foramen. Afterwards, they were divided in five groups containing twenty elements each, according to the obturation technique employed: 1. lateral condensation with Kerr file; 2. continuous wave of condensation technique with System B; 3. thermoplasticized injectable gutta-percha technique with the Ultrafil system; 4. mechanically thermoplasticized gutta-percha with the JS Quick-Fill system and 5. thermoplasticized gutta-percha associated to a master cone with the Microseal system. The six remaining teeth were employed as negative and positive controls. After obturation, the access cavities were sealed and the teeth were immersed in aqueous 2% methylene blue dye for 72 hours at 37ºC. After that, the teeth were longitudinally sectioned and the apical microleakage was evaluated in a stereomicroscope. The Microseal system presented the best apical sealing ability, followed by System B, JS Quick-Fill, Ultrafil and the lateral condensation technique. The statistical analysis of the results demonstrated that: 1. the Microseal system presented an apical sealing similar to System B and better than the other groups; 2. System B presented better apical sealing than the lateral condensation technique, being similar to the other groups; and 3. the lateral condensation, Ultrafil and JS Quick-Fill groups demonstrated similar sealing ability.Este estudo teve como objetivo avaliar o selamento apical de canais radiculares obturados por diferentes técnicas. Cento e seis incisivos inferiores humanos tiveram seus canais instrumentados através da técnica escalonada regressiva. Após a

  7. Single-visit endodontic treatment of mature teeth with chronic apical abscesses using mineral trioxide aggregate cement: a randomized clinical trial.

    Science.gov (United States)

    Alsulaimani, Reem Siraj

    2016-08-23

    Mature teeth with chronic apical abscesses characterized by intermittent discharge of pus through an associated sinus tract. This communication between oral mucosa and periapical inflammation is challenging for the sealing ability of root canal obturation material. Therefore, the study aim was to compare the outcomes of endodontic treatment using mineral trioxide aggregate (MTA) cement to the conventional gutta-percha cone and root canal sealer as an obturation material in mature teeth with chronic apical abscesses. Mature teeth with chronic apical abscesses referred to our clinic for root canal treatment between 2010 and 2012 were treated in a single visit and distributed among treatment (T) and control (C) groups using a predetermined randomization block (TCTC). After chemo-mechanical preparation, teeth in group T received MTA cement mixed in a 0.26 water to powder ratio, and teeth group C received gutta-percha and root canal sealer using the warm vertical technique. The treatment outcomes were defined as obturation length, periapical healing, resorption of extruded material, and survival rate at least 2.5 years after treatment. Three endodontists blinded to the type of obturation material documented treatment outcomes. Statistical analysis at P chronic apical abscesses using MTA cement were better, but not statistically significant, compared to conventional treatment. ISRCTN15285974 . Registered retrospectively 23 June 2015.

  8. Root canal adhesive filling in dogs' teeth with or without coronal restoration: a histopathological evaluation.

    Science.gov (United States)

    Leonardo, Mario Roberto; Barnett, Frederick; Debelian, Gilberto J; de Pontes Lima, Regina Karla; Bezerra da Silva, Léa Assed

    2007-11-01

    The purpose of this study was to evaluate in vivo the response of the periradicular tissues after endodontic treatment and root filling with Epiphany/Resilon (Penntron Clinical Technologies, LLC, Wallingford, CT) or gutta percha and new Sealapex (SybronEndo, Glendora, CA) in dogs' teeth with or without coronal restoration. Teeth without coronal restorations were used to assess the influence of continuous exposure to the oral environment on the periradicular tissues. Sixty root canals with vital pulps in three dogs were instrumented and obturated in a single session and randomly assigned to one of four groups as follows. group 1: root canal filling with Epiphany/Resilon with coronal restoration, group 2: root canal filling with Sealapex sealer and gutta percha with restoration, group 3: root canal filling with Epiphany/Resilon without restoration, and group 4: root canal filling with Sealapex sealer and gutta percha without coronal restoration. After 90 days, the animals were euthanized, and the maxillas and mandibles were removed and submitted for histologic processing. Longitudinal sections were obtained and stained with hematoxylin and eosin, Mallory's trichrome, and Brown and Brenn stains and examined under light microscopy. There were significant differences found between the four groups (p < 0.05). The results showed that roots canals filled with Epiphany/Resilon, with coronal restoration, had significantly less periradicular inflammation than roots canals filled with gutta percha and Sealapex, with coronal restoration (p = 0.021). No significant difference was observed in the intensity of inflammation between roots canals filled with Epiphany/Resilon with no restoration and roots filled with gutta percha and Sealapex with restoration (p = 0.269). Roots canals filled with gutta percha and Sealapex sealer without coronal restoration showed the greatest degree of periradicular inflammation.

  9. Evaluation of the Apical Sealability of Mineral Trioxide Aggregate and Portland Cement as Root Canal Filling Cements: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    M.S. Rekab

    2010-12-01

    Full Text Available Objective: One of the principle purposes of root canal obturation is to obtain hermetic sealing of the root canal system. According to the development of technology, many materials are now used in root canal filling. An in vitro dye leakage study was performed toevaluate the apical sealability of White-colored Mineral Trioxide Aggregate (WMTA and Gray-colored Portland Cement (GPC when used alone or as a sealer with gutta-percha points in root canal filling.Materials and Methods: Seventy-five single-rooted extracted human teeth were used in this study. After cleaning and shaping, the teeth were randomly divided into five equal groups of 15 teeth each based on the root canal filling material used; Group 1, (WMTAalone; Group 2, (GPC alone; Group 3, (Gutta-percha points + WMTA; Group 4,(Guttapercha points + GPC; Group 5, (Gutta-percha points + AH26. Methylene blue was used to determine the apical leakage. After sectioning the teeth longitudinally, linear dye penetrationwas measured with a caliper under the stereomicroscope. Data were analyzed by Kruskal-Wallis and one-way ANOVA tests with (P 0.05 as the level of significance.Results: The results showed that there were no statistically significant differences among the materials of five groups.Conclusion: (WMTA alone, (Gutta-percha points + WMTA, (GPC alone and (Guttapercha points + GPC may be used in the root canal filling.

  10. Fitness of gutta-percha cones in curved root canals prepared with reciprocating files correlated with tug-back sensation.

    Science.gov (United States)

    Yoon, Heeyoung; Baek, Seung-Ho; Kum, Kee-Yeon; Kim, Hyeon-Cheol; Moon, Young-Mi; Fang, Denny Y; Lee, WooCheol

    2015-01-01

    The purpose of this study was to evaluate the gutta-percha-occupied area (GPOA) and the relationship between GPOA and tug-back sensations in canals instrumented with reciprocating files. Twenty curved canals were instrumented using Reciproc R25 (VDW, Munich, Germany) (group R) and WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) (group W), respectively (n = 10 each). The presence or absence of a tug-back sensation was decided for both of #25/.08 and #30/.06 cones in every canal. The percentage of GPOA at 1-, 2-, and 3-mm levels from the working length was calculated using micro-computed tomographic imaging. The correlation between the sum of the GPOA and the presence of a tug-back sensation was also investigated. The data were analyzed statistically at P = .05. A tug-back sensation was present in 45% and 100% canals for #25/.08 and #30/.06 cones, respectively, with a significant difference (P sensation (P .05). Under the conditions of this study, the tug-back sensation can be a definitive determinant for indicating higher cone fitness in the curved canal regardless of the cone type. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Histopathological and histomicrobiological study of root canal therapy medication, comparison of calcium hydroxide versus gutta-percha with zinc oxide/eugenol in the teeth of dogs Avaliação histopatológica e histomicrobiológica de dentes de cães, após tratamento endodôntico com hidróxido de cálcio e guta-percha com óxido de zinco e eugenol

    Directory of Open Access Journals (Sweden)

    Léslie M. Domingues-Falqueiro

    2007-02-01

    Full Text Available The presence of microorganisms in dental structures with experimentally induced necrosis was evaluated. The materials were tested to evaluate their antimicrobial activity and tissue repair efficacy. Four dogs were used in this experiment, with a total of 64 roots of premolar teeth, divided into three groups. The root canals of Group I were filled with gutta-percha and zinc oxide/eugenol cement; Group II were filled with calcium hydroxide, and Group III were not filled. All animals were clinically and radiographically examined 15 days after surgery andthen again every subsequent 15 days until 120 days, when the teeth were extracted en bloc.Histopathological analysis showed inflammatory infiltration, cement and bone resorption andnecrotic tissue in the apical delta in different proportions. Histomicrobiological analysis showedthe presence of microorganisms inside the teeth structures, with different concentrationsaccording to the treatment used. There was statistical significance between the groups(p>0.05. Gutta-percha with zinc oxide/eugenol demonstrated good antimicrobial activity;calcium hydroxide was not efficient. The conclusion of this study is that gutta-percha withzinc oxide/eugenol is the better protocol for filling root canals in dogs.Avaliou-se a presença de microrganismos nas estruturas dentais com necrose pulpar induzida experimentalmente, testando a eficácia de materiais com relação à atividade antibacteriana e influência no reparo tecidual. Utilizaram-se quatro cães, totalizando 64 raízes, provenientes de pré-molares, divididas em grupos. O Grupo I foi obturado com guta percha e cimento à base de óxido de zinco e eugenol, o Grupo II, com hidróxido de cálcio e o Grupo III, não foram obturados. Todos tiveram controle clínico e radiográfico quinzenal e após 120 dias, foram extraídos em bloco para análises. A histopatologia evidenciou infiltrado inflamatório, reabsorção cementária e óssea e tecido necrótico no

  12. Effect of immediate and delayed post space preparation on the apical seal of root canals obturated with different sealers and techniques

    Directory of Open Access Journals (Sweden)

    Hikmet Aydemir

    2009-12-01

    Full Text Available During mechanical preparation of the post space, the root canal filling may be twisted or vibrated, depending on several factors associated with the preparation technique and quality of filling. OBJECTIVE: The purpose of this study was to investigate the effect of immediate and delayed post space preparation on the integrity of the apical seal. MATERIAL AND METHODS: Sixty-four extracted human incisors were biomechanically prepared using the step-back technique. Sixty roots were randomly assigned to 6 experimental groups of 10 teeth each and the remaining 4 roots served as positive and negative controls (n=2. The root canals in the different groups were obturated with cold lateral and warm vertical condensation of gutta-percha and one of two sealers (Sealapex and Diaket. Post space was prepared either individually or simultaneously. An insulated copper wire was cut into 10-cm-long pieces. In each canal, one piece was inserted to maintain contact with gutta-percha and extended to the outside as one of two working electrodes. A stainless steel wire with the same dimensions of those of the copper wire, used as the other working electrode, was immersed into the background electrolyte from the center of the bottle. The electrical current between standard and experimental electrodes in canals was measured over a period of 10 days applying a conductivity meter. The Kruskal-Wallis test (p=0.05 determined whether there was a significant difference in microleakage among the groups and the Mann-Whitney U test (p=0.01 was used for multiple comparison grouping variables. RESULTS: The results suggest that only the differences between the root canal filling techniques were statistically significant (p0.01. CONCLUSION: The quality of the root canal filling is important for the integrity of the apical seal.

  13. Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

    Directory of Open Access Journals (Sweden)

    Özgür Genç

    2011-08-01

    Full Text Available OBJECTIVE: The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth. MATERIAL AND METHODS: 85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device. RESULTS: All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (p<0.05. Lightspeed ranked in between. Leakage was similar for all techniques at either period. However, all groups leaked significantly more at 3 months compared to 1 week (p<0.05. CONCLUSIONS: Despite statistically significant differences found among the techniques, deviations from the predetermined level were small and clinically acceptable for all techniques. Leakage following obturation was comparable in all groups.

  14. Effect of Instrument Design and Access Outlines on the Removal of Root Canal Obturation Materials in Oval-shaped Canals.

    Science.gov (United States)

    Niemi, Tuomas K; Marchesan, Melissa A; Lloyd, Adam; Seltzer, Robert J

    2016-10-01

    The aim of this study was to compare the effectiveness of TRUShape (TS) instruments with ProFile Vortex Blue (VB) instruments for the removal of obturation materials during retreatment of single-canal mandibular premolars performed through 2 access outlines. Initial root canal treatment was completed through a contracted endodontic cavity (CEC) design. Canals were instrumented to an F2 ProTaper instrument, obturated with warm lateral condensation of gutta-percha with AH Plus sealer, and allowed to set for 30 days at 37°C and 100% humidity. For retreatment, specimens were divided into 2 groups (n = 24) on the basis of access outline, CEC or traditional endodontic cavity (TEC). Retreatment was initiated by using ProTaper Retreatment instruments (D1-D3). Specimens were then stratified, further divided (n = 12), and reinstrumented up to TS 40 .06v or 40 .06 VB. Irrigation was performed by using 8.25% NaOCl and QMix 2in1. Retreatment time was recorded. Teeth were sectioned and photographed, and the percentage of remaining obturation materials was measured. Data were analyzed with Kruskal-Wallis analysis of variance for two-factor tests (α canal surface when compared with TEC-VB, CEC-TS, and TEC-TS (P ≤ .05). None of these other combinations were different from each other (P > .05). Significantly more time was required for retreatment with CEC-TS (27.68 ± 1.4 minutes) than the other groups (P root canal surface of mandibular premolars. However, in the presence of a CEC access design, using TS instruments removed more obturating material in single-rooted, oval-shaped canals. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Spiral computed tomography assessment of the efficacy of different rotary versus hand retreatment system.

    Science.gov (United States)

    Mittal, Neelam; Jain, Jyoti

    2014-01-01

    The purpose of this study was to evaluate the efficacy of nickel-titanium rotary retreatment systems versus stainless steel hand retreatment system with or without solvent for gutta-percha removal during retreatment. Sixty extracted human mandibular molar teeth with single canal in a distal root was prepared with ProTaper rotary nickel-titanium files and obturated with gutta-percha and sealer. The teeth were randomly divided into six groups of 10 specimens in each groups. The volume of filling material before and after retreatment were evaluated in cm(3) using the computed tomography (CT) scanner proprietary software. Maximum amount of filling material removed during retreatment with ProTaper retreatment system with solvent and minimum with hand retreatment system with solvent. None of the technique was 100% effective in removing the filling materials, but the ProTaper retreatment system with solvent was better.

  16. Comparison of post-obturation pain experience following one-visit and two-visit root canal treatment on teeth with vital pulps: a randomized controlled trial.

    Science.gov (United States)

    Wang, C; Xu, P; Ren, L; Dong, G; Ye, L

    2010-08-01

    To compare the incidence and intensity of post-obturation pain after one- or two-visit root canal treatment (RCT) on anterior teeth with vital pulps and a single root and canal in a randomized controlled trial. One hundred patients requiring RCT on permanent anterior teeth with vital pulps preoperatively were included. The patients were assigned randomly into two groups of 50 patients each. After local anaesthesia, isolation, access and pulp extirpation, the canals of all teeth were prepared using engine-driven rotary ProTaper nickel-titanium instruments in a crown-down technique and irrigated with 2.5% NaOCl. The teeth in group 1 (n = 50) were filled with AH Plus sealer and gutta-percha using a lateral compaction technique at the first visit, whilst those in group 2 (n = 50) were medicated with a calcium hydroxide paste, a sterile dry cotton pellet and Caviton and scheduled for a second visit 7 days later. A modified verbal descriptor scale was used to measure preoperative pain and post-obturation pain at 6, 24, 48 h and 1 week after operation. Chi-square tests and independent-sample T-tests were used to compare the incidence and intensity of post-obturation pain of two groups at each interval. Eleven patients were excluded from the study as they failed to follow the scheduled revisit or their selected teeth had more than one root canal. Data were obtained from the remaining 89 patients. Forty-three patients were undergoing one-visit treatment (group 1) and 46 undergoing two-visit treatment (group 2). Most patients in both groups reported no pain or only slight pain within each post-obturation interval, only one in group 1 and one in group 2 had flare-ups and slight swelling. There was no statistically significant difference in the incidence and intensity of post-obturation pain experienced by two groups. The incidence and intensity of post-obturation pain experience following one- or two-visit RCT on teeth with vital pulps and a single canal were not

  17. The Comparative Efficacy of Different Files in The Removal of Different Sealers in Simulated Root Canal Retreatment- An In-vitro Study.

    Science.gov (United States)

    Kanaparthy, Aruna; Kanaparthy, Rosaiah

    2016-05-01

    Root canal treatment enjoys a high success rate all over the world and has saved billions of teeth from extraction. However, there are instances of failure, the main causes being insufficient cleaning and inadequate obturation. In such cases the most conservative treatment option would be non-surgical retreatment. It requires regaining access to the entire root canal system through removal of the original root canal filling thus permitting further cleaning and re- obturation. Removal of gutta-percha and sealer becomes a critical step to gain access to the root canal system, remove necrotic tissue debris, bacteria and infected dentin. To compare and evaluate the efficacy of manual hand Hedstrom files and two rotary retreatment file systems ProTaper Universal retreatment files and Mtwo(R) (retreatment) files in the removal of root canal filling material during root canal retreatment and the influence of the type of sealers zinc oxide eugenol and AH plus on the presence of remaining debris in the reinstrumented canals in the apical, middle and coronal third. Sixty single rooted human premolar teeth were divided into 3 Groups of 20 teeth each Group I (20 Teeth): prepared using hand K Files, Group II (20 Teeth): prepared using ProTaper rotary system and Group III (20 Teeth): prepared using Mtwo rotary system. In Groups- IA, IIA, IIIA: (10 teeth each) Obturation was done using Zinc Oxide Eugenol sealer and gutta percha. In Groups- IB, IIB, IIIB: (10 teeth each) obturation was done with AH Plus sealer and gutta percha. All the teeth were subjected to retreatment. Groups IA and IB with Hedstrom files, Groups IIA and IIB with ProTaper retreatment files and for Groups IIIA and IIIB with Mtwo retreatment Files. The roots were longitudinally split and were observed under a stereomicroscope for remaining amount of filling material on the canal walls. Statistical analysis was done using One-way ANOVA (Analysis of variance) test and Tukey HSD Test. Mtwo(R) files showed

  18. The efficacy of ProTaper Universal rotary retreatment instrumentation to remove single gutta-percha cones cemented with several endodontic sealers.

    Science.gov (United States)

    Ersev, H; Yilmaz, B; Dinçol, M E; Dağlaroğlu, R

    2012-08-01

    To evaluate residual root filling material following removal of three newly developed root canal sealers used with a matched-taper single-cone root filling technique and to compare the efficacy of ProTaper Universal rotary retreatment instruments with that of a conventional manual technique. The canals of 120 palatal roots in maxillary molar teeth were instrumented with EndoWave nickel-titanium rotary instruments and filled using Hybrid Root SEAL, EndoSequence BC Sealer, Activ GP system or AH Plus with matched-taper single gutta-percha cones. The root fillings were then removed with ProTaper Universal retreatment rotary instruments or a manual technique. Buccolingual and proximal digital radiographs of the roots were exposed to determine the area of remaining filling material in the coronal, middle and apical thirds. The area percentages of remaining filling material in each third and total canal area were calculated. Data were analysed statistically with Kruskal-Wallis and Mann-Whitney U-tests. The level of significance was set at PProTaper groups. When using gross radiographic criteria, the Activ GP was more effectively removed from root canals than AH Plus with hand instrumentation. Hybrid Root SEAL, EndoSequence BC Sealer and AH Plus were removed to a similar extent. ProTaper Universal retreatment instruments were as safe and effective as hand instruments in reaching the working length. © 2012 International Endodontic Journal.

  19. One-visit endodontic retreatment of combined external/internal root resorption using a calcium-enriched mixture.

    Science.gov (United States)

    Asgary, Saeed; Ahmadyar, Maryam

    2012-01-01

    Combined external and internal root resorption (ERR/IRR) is a rare endodontic disease that leads to alteration of the root canal anatomy. This report describes the management of an endodontically failed molar that was severely affected by ERR/IRR. Radiographic examination demonstrated inadequate obturation of the root canals associated with ERR/IRR and a large periradicular lesion. During nonsurgical endodontic retreatment, the root canals were subjected to conventional chemomechanical debridement. In the same session, the entire distal root canal was obturated using a calcium-enriched mixture (CEM) cement, and the mesial canals were obturated with gutta-percha/sealer. The clinical findings and follow-up radiographs indicated favorable treatment outcomes after 12 months. One-visit application of CEM cement could be a successful approach for the management of combined ERR/IRR.

  20. [Distortion and vertical fracture of the root: effect produced by condenser design].

    Science.gov (United States)

    Dang, D A; Walton, R E

    1990-01-01

    The incidence of vertical root fractures and the amount of root distortion created during lateral condensation of gutta-percha with either D11 spreaders or B-finger pluggers were evaluated in vitro. Fifty-five extracted human, single-rooted teeth were instrumented using the step-back flare technique. Ten teeth served as positive controls (obturation to the point of fracture) and five teeth as negative controls (prepared but not obtured). Strain gauges were attached to the root surfaces. In the experimental group, 20 teeth were obturated using a D11 spreader and 20 with a B-finger plugger. Recordings were made of root distortion (expansion) created during obturation. Then, after sectioning the teeth, root surfaces of obturated samples were examined for fractures under the scanning electron microscope. Only the more tapered spreader, the D11, produces vertical root fractures, although very few in number. Also, the D11 spreader caused greater root distortion than did the B-finger plugger.

  1. A Comparison of the Area of the Canal Space Occupied by Gutta Percha Following Four Gutta-Percha and Sealer Obturation Techniques.

    Science.gov (United States)

    1983-06-01

    resorption , is well accepted by the specialty of endodontics (1,4-6). Isotope and dye studies have generally demonstrated that complete obliteration...resist resorption well (3,4). Studies have also exhibited the irritational properties of sealers and demonstrated that they do shrink slightly (5-8). The...teeth were then boxed using baseplate wax (Fig 2C), the teeth embedded in clear orthodontic resin and cured under water at 20 lbs. of pressure (Fig 2D

  2. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study.

    Science.gov (United States)

    Kasam, Swetha; Mariswamy, Annapoorna Ballagere

    2016-06-01

    Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm(2). Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe's post hoc test through SPSS for windows (v 16.0). The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. All techniques retained guttapercha

  3. Evaluation of the radiopacities of four different root canal sealers by digital radiographic technique

    Directory of Open Access Journals (Sweden)

    Özgür Özdemir

    2016-05-01

    Full Text Available OBJECTIVE: The aim of this study was to compare the radiopacities of four different root canal sealers and gutta-percha. MATERIALS AND METHOD: AH Plus, iRootSP, MTA Fillapex and Sealapex as root canal sealers and gutta-percha cones were tested. Standardized discs of the root canal sealers and the gutta-percha were prepared. Digital radiographs of the discs and an aluminum penetrometer were obtained by using a phosphor plate. The radiographic density of the sealers and the gutta-percha were measured by using the digital radiographic system’s own measurement tool, and equivalent aluminum thicknesses were determined by using an image editing software. Differences among radiopacities of the root canal sealers and the gutta-percha were analyzed using One-way ANOVA and Tukey post-hoc tests. RESULTS: Aluminum thickness equivalents of the radiopacity values of the samples, in descending order, were: AH Plus, Sealapex, iRootSP, MTA Fillapex and gutta-percha. No significant difference was found between the radiopacity values of AH Plus and Sealapex (p>0.05. There were statistically significant differences between these two groups (AH Plus and Sealapex and all other experimental groups (p<0.05. CONCLUSION: AH Plus and Sealapex exhibited the highest radiopacity values among tested groups. In addition, all tested materials fulfilled the minimum standard value requirements suggested by International Standardization Organization and American National Standards Institute.

  4. Endodontic and Prosthetic Management of a Mid-Root and Crown Fracture of a Maxillary Central Incisor

    Directory of Open Access Journals (Sweden)

    Koidou Vasiliki P.

    2014-11-01

    Full Text Available Root fractures are relatively uncommon among other dental traumas and mostly affect the anterior dentition. This case report presents the endodontic and prosthodontic management of a maxillary central incisor with a combined fracture in the middle third of the root and the crown, as well as the 7-year follow up of the case. The healing potential of a horizontal root fracture in the middle third of the root is highlighted when appropriate treatment is applied. MTA used for obturation of the coronal fragment, induced hard tissue formation apically and promoted healing in the area, while the 2mm MTA left as apical barrier at the second stage of re-treatment and obturation with gutta-percha prevented its extrusion. The multidisciplinary approach in the management of such cases ensures a long term survival.

  5. Micro-CT evaluation of the effectiveness of the combined use of rotary and hand instrumentation in removal of Resilon.

    Science.gov (United States)

    Asheibi, Fatma; Qualtrough, Alison J E; Mellor, Anthony; Withers, Philip J; Lowe, Tristan

    2014-01-01

    This study compares the effectiveness of ProTaper rotary files with ProTaper retreatment and K-files in the removal of Resilon or gutta percha (GP) from canals filled either by cold lateral condensation or thermal obturation using micro-CT. Ninety-six teeth were prepared using ProTaper files and allocated into four groups (n=24): Group-1 was filled with GP/AH-Plus and Group-2 with Resilon/RealSeal using cold lateral condensation. Group-3 was filled with GP/AH-Plus and Group-4 with Resilon/RealSeal using System B and Obtura II. The roots were scanned by micro-CT. Each group was divided into two subgroups (n=12): A, retreated using ProTaper files and B, using ProTaper retreatment and K-files. The roots were scanned to calculate the volume of the remaining material. With thermal obturation, roots filled with Resilon had significantly more remaining material than GP. Obturation using thermal technique resulted in significantly less remaining material than cold condensation except Resilon retreated using ProTaper retreatment and K-files.

  6. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  7. Thermafil: A New Clinical Approach Due to New Dimensional Evaluations

    Science.gov (United States)

    Vittoria, G.; Pantaleo, G.; Blasi, A.; Spagnuolo, G.; Iandolo, A.; Amato, M.

    2018-01-01

    Background: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). Objective: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. Methods: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. Results: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. Conclusion: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions. PMID:29541263

  8. Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study.

    Science.gov (United States)

    Rödig, T; Hausdörfer, T; Konietschke, F; Dullin, C; Hahn, W; Hülsmann, M

    2012-06-01

    To compare the efficacy of two rotary NiTi retreatment systems and Hedström files in removing filling material from curved root canals. Curved root canals of 57 extracted teeth were prepared using FlexMaster instruments and filled with gutta-percha and AH Plus. After determination of root canal curvatures and radii in two directions, the teeth were assigned to three identical groups (n = 19). The root fillings were removed with D-RaCe instruments, ProTaper Universal Retreatment instruments or Hedström files. Pre- and postoperative micro-CT imaging was used to assess the percentage of residual filling material as well as the amount of dentine removal. Working time and procedural errors were recorded. Data were analysed using analysis of covariance and analysis of variance procedures. D-RaCe instruments were significantly more effective than ProTaper Universal Retreatment instruments and Hedström files (P ProTaper group, four instrument fractures and one lateral perforation were observed. Five instrument fractures were recorded for D-RaCe. D-RaCe instruments were associated with significantly less residual filling material than ProTaper Universal Retreatment instruments and hand files. Hedström files removed significantly less dentine than both rotary NiTi systems. Retreatment with rotary NiTi systems resulted in a high incidence of procedural errors. © 2012 International Endodontic Journal.

  9. Heat release, time required, and cleaning ability of MTwo R and ProTaper universal retreatment systems in the removal of filling material.

    Science.gov (United States)

    Bramante, Clovis Monteiro; Fidelis, Natasha Siqueira; Assumpção, Tatiana Santos; Bernardineli, Norberti; Garcia, Roberto Brandão; Bramante, Alexandre Silva; de Moraes, Ivaldo Gomes

    2010-11-01

    This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 °C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, α = 0.05). None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    Science.gov (United States)

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. A comparison of the sealing ability of various temporary restorative materials to seal the access cavity: An in vitro study

    Directory of Open Access Journals (Sweden)

    Aji Markose

    2016-01-01

    Full Text Available Introduction: In multiple-appointment root canal treatment, a temporary filling material is used to seal the access cavity between visits. The primary function of this material is to prevent the contamination of the root canal system by fluids, organic debris, and bacteria from the oral cavity. Material and Methods: A total of fifty extracted noncarious unrestored human maxillaryanterior teeth with intact crowns and roots were selected The canals were instrumented using stepback technique and sodium hypochlorite (3% and hydrogen peroxide (3% were used as irrigants for each specimen alternatively. The coronal two-thirds of each canal were flared using Gates-Glidden drills up to no. 3 size and obturated with Gutta-percha using zinc oxide-eugenol (ZnOE as sealer. The teeth were then randomly selected and divided into six groups out of which four were experimental groups and two control groups. The teeth were then immersed in 2% methylene blue dye solution for 3 days. All sealing materials and Gutta-percha were gently removed from the walls of the canal, and the entire circumference of the canal wall examined for dye penetration. Results: The lowest mean leakage was in the Fermit-N group followed by Cavit-W, ZnOE, intermediate restorative materials (IRM, and positive control. Conclusion: Fermit-N showed better sealing ability compared to cavit, ZnOE and IRM.

  12. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Full Text Available Introduction: Root canal obturation aims at sealing the root canal system to prevent re-contamination of canal and periapical space. Presence of moisture in canal before obturation may posit a negative effect on the quality of canal sealing. Therefore, this study was conducted to investigate the effect of canal contamination with saliva on apical microleakage. Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  13. Root canal revascularization. The beginning of a new era in endodontics.

    Science.gov (United States)

    Alrahabi, Mothanna K; Ali, Mahmoud M

    2014-05-01

    Endodontic management of immature anterior teeth with necrotic pulps is a great challenge. Although there are different treatment procedures to deal with this problem such as apexification by using calcium hydroxide dressings or applying a barrier of mineral trioxide aggregate and gutta-percha obturation, the outcomes are still unsatisfactory and the root might still be weak. Recently, a new treatment protocol by revascularization of immature non-vital, infected teeth was introduced to regenerate dental structure and complete the root maturation. However, larger case series with longer follow-up periods are required to accept revascularization as the standard protocol for management of immature non-vital, infected teeth. In this review, we discuss the concept of root canal revascularization, revascularization mechanisms, and the structure of the regenerated tissues.

  14. Periapical tissue response after use of intermediate restorative material, gutta-percha, reinforced zinc oxide cement, and mineral trioxide aggregate as retrograde root-end filling materials: a histologic study in dogs.

    Science.gov (United States)

    Wälivaara, Dan-Åke; Abrahamsson, Peter; Isaksson, Sten; Salata, Luiz Antonio; Sennerby, Lars; Dahlin, Christer

    2012-09-01

    To investigate the periapical tissue response of 4 different retrograde root-filling materials, ie, intermediate restorative material, thermoplasticized gutta-percha, reinforced zinc oxide cement (Super-EBA), and mineral trioxide aggregate (MTA), in conjunction with an ultrasonic root-end preparation technique in an animal model. Vital roots of the third and fourth right mandibular premolars in 6 healthy mongrel dogs were apicectomized and sealed with 1 of the materials using a standardized surgical procedure. After 120 days, the animals were sacrificed and the specimens were analyzed radiologically, histologically, and scanning electron microscopically. The Fisher exact test was performed on the 2 outcome values. Twenty-three sections were analyzed histologically. Evaluation showed better re-establishment of the periapical tissues and generally lower inflammatory infiltration in the sections from teeth treated with the intermediate restorative material and the MTA. New root cement on the resected dentin surfaces was seen on all sections regardless of the used material. New hard tissue formation, directly on the surface of the material, was seen only in the MTA sections. There was no statistical difference in outcome among the tested materials. The results from this dog model favor the intermediate restorative material and MTA as retrograde fillings when evaluating the bone defect regeneration. MTA has the most favorable periapical tissue response when comparing the biocompatibility of the materials tested. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Assessment of vertical fracture using cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moudi, Ehsan; Madani, Zahrasadat; Alhavaz, Abdolhamid; Bijani, Ali [Dental Material Research Center, Dental School, Babol University of Medical Sciences, Babol, (Korea, Republic of); Bagheri, Mohammad [Social Determinants of Health Research Center, Babol University of Medical Sciences, Babol (Korea, Republic of)

    2014-03-15

    The aim of this study was to investigate the accuracy of cone-beam computed tomography (CBCT) in the diagnosis of vertical root fractures in a tooth with gutta-percha and prefabricated posts. This study selected 96 extracted molar and premolar teeth of the mandible. These teeth were divided into six groups as follows: Groups A, B, and C consisted of teeth with vertical root fractures, and groups D, E, and F had teeth without vertical root fractures; groups A and D had teeth with gutta-percha and prefabricated posts; groups B and E had teeth with gutta-percha but without prefabricated posts, and groups C and F had teeth without gutta-percha or prefabricated posts. Then, the CBCT scans were obtained and examined by three oral and maxillofacial radiologists in order to determine the presence of vertical root fractures. The data were analyzed using IBM SPSS 20.0 (IBM Corp., Armonk, NY, USA). The kappa coefficient was 0.875 ± 0.049. Groups A and D showed a sensitivity of 81% and a specificity of 100%; groups E and B, a sensitivity of 94% and a specificity of 100%; and groups C and F, a sensitivity of 88% and a specificity of 100%. The CBCT scans revealed a high accuracy in the diagnosis of vertical root fractures; the accuracy did not decrease in the presence of gutta-percha. The presence of prefabricated posts also had little effect on the accuracy of the system, which was, of course, not statistically significant.

  16. Orthograde endodontic retreatment of teeth with individual cast posts: Report of two cases

    Directory of Open Access Journals (Sweden)

    Ramić Bojana

    2012-01-01

    Full Text Available Introduction. The failure of primary endodontic treatment is manifested by various clinical symptoms following endodontic therapy or, more frequently, by the development of chronic inflammatory process in the apex region without any subjective symptoms. In case of unfavorable outcome of the primary endodontic treatment, orthograde endodontic retreatment is the method of choice for a prolonged therapy. Outline of Cases. Two female patients, 47 and 44 years old, were presented at the Dental Clinic of Vojvodina for endodontic retreatment of teeth 22, 23 and 13, within the repeated prosthetic restoration. Intraradicular individual cast posts were removed using ultrasonic instruments. Remains of gutta-percha were removed by engine driven rotary re-treatment files, root canals were shaped and cleaned using the crown-down technique, and obturated with gutta-percha and epoxy-resin-based sealer using the lateral compaction technique. Conclusion. When there are metal posts or broken instruments in the root canal, the use of ultrasonic instruments is considered a safe method characterized by negligible tooth substance loss and minimal root damage causing fractures and perforations, and the entire procedure is effective and predictable. Non-surgical orthograde endodontic retreatment, when properly performed in accessible and penetrable root canals, achieves a high cure rate, good and lasting results and eliminates the need for radical procedures, such as apical surgery or tooth extraction. When nonsurgical endodontic retreatment is done, treated teeth must be restored by full coronal coverage as soon as possible, to prevent coronal leakage or fracture.

  17. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  18. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Sealing ability of cermet ionomer cement as a retrograde filling material.

    Science.gov (United States)

    Aktener, B O; Pehlivan, Y

    1993-03-01

    An in vitro dye leakage study was performed to compare the sealing ability of high copper amalgam with cavity varnish and cermet ionomer cement with and without varnish when used as retrofilling materials. The root canals of 54 maxillary anterior teeth were instrumented and obturated with gutta-percha and sealer. The apical 3 mm of the roots were resected and apical class I cavity preparations were made. The roots were then randomly divided into three groups and retrofilled with one of the experimental materials. After 72 h of immersion in India ink, the roots were cleared and evaluated for leakage with a stereomicroscope. Statistical analysis indicated that the cermet ionomer cement with varnish group had significantly less leakage than the amalgam group (P cermet ionomer cement without varnish group (P 0.05).

  20. Effect of four different intracanal medicaments on the apical seal of the root canal system: a dye extraction study.

    Science.gov (United States)

    Tandan, Monika; Hegde, Mithra N; Hegde, Priyadarshini

    2014-01-01

    The aim was to determine the effect of four different intracanal medicaments on the apical seal of the root canal system in vitro. Fifty freshly extracted intact human permanent maxillary central incisors were collected, stored and disinfected. The root canals were prepared to a master apical size of number 50 using step back technique. Depending upon the intracanal medicament used, the teeth were divided randomly into five groups of 10 teeth each including one control group and four experimental groups. Group A: No intracanal medicament. Group B: Calcium hydroxide powder mixed with distilled water. Group C: Calcium hydroxide gutta percha points (calcium hydroxide points). Group D: 1% chlorhexidine gel (hexigel). Group E: Chlorhexidine gutta percha points (Roeko Activ Points). The medication was left in canals for 14 days. Following removal of the intracanal medicament, all the groups were obturated with lateral compaction technique. The apical leakage was then evaluated using dye extraction method with the help of a spectrophotometer. RESULTS were statistically analyzed using Kruskal-Wallis and Mann-Whitney U-test, which showed statistically significant difference among the five groups tested. It can be concluded from this study that the control group showed least amount of leakage, whereas the 1% chlorhexidine gel group showed maximum amount of leakage. Apical leakage was observed with all the experimental groups with little variations in between them. Under the parameters of this study, it can be concluded that use of intracanal medicaments during endodontic treatment has a definite impact on the apical seal of the root canal system.

  1. RTV-silikon sebagai Bahan Protesa Obturator Palatum

    OpenAIRE

    Chandrasegar, Akila

    2011-01-01

    Protesa Obturator palatum adalah protesa yang digunakan untuk menutup jaringan yang terbuka secara kongenital atau yang diperdapat, terutama bagian palatum keras atau lunak serta struktur alveolar yang berdekatan. Obturator palatum dapat diklasifikasikan berdasar pada tahap perawatannya yaitu obturator selama pembedahan (surgical obturator), obturator interim dan obturator definitif. Terdapat beberapa tipe obturator selain dari obturator palatum seperti obturator palato fari...

  2. Novel apexification method in a non-vital tooth with an open apex: a case report.

    Directory of Open Access Journals (Sweden)

    Hamid Razavian

    2014-06-01

    Full Text Available Many materials have been introduced for apexification each having their own advantages and disadvantages. This case report aims to present a new method of apexification using a combination of deproteinized bovine bone mineral (DBBM and enamel matrix derivative (EMD. After irrigating the canal of the maxillary right canine with 2.5 % sodium hypochlorite, a mixture of Bio-Oss and EMD was packed into the apical region for formation of an apical barrier and the canal was obturated by thermoplastic gutta percha technique with AH26 sealer; coronal seal was achieved by resin bonded composite. The size of the periapical lesion decreased significantly after 3, 6, 12 and 18-months. The patient had no radiographic signs or clinical symptoms at 24-month follow up and complete maturation of the apex and healing of the periapical bone were achieved.

  3. Comparison of bond strength of different endodontic sealers to root dentin: An in vitro push-out test.

    Science.gov (United States)

    Madhuri, G Vijaya; Varri, Sujana; Bolla, Nagesh; Mandava, Pragna; Akkala, Lakshmi Swathi; Shaik, Jaheer

    2016-01-01

    To compare the bond strength of four different endodontic sealers to root dentin through push-out test design. Forty single-rooted teeth with completely formed apices were selected. Teeth were decoronated, and working length was determined. Instrumentation and irrigation were performed. The teeth were divided into four groups based upon the sealer used. Group 1: Bioceramic sealer (Endosequence), Group 2: Mineral trioxide aggregate (MTA) based sealer (MTA Fill apex), Group 3: Epoxy resin based sealer (MM-Seal), and Group 4: Dual cure resin-based sealer (Hybrid Root Seal). Manipulation and application of the sealer was done as per the manufacturer instructions. All the teeth were obturated using 6% gutta-percha. After obturation, each tooth was prepared for push-out test with root slices of 2 mm thickness using universal testing machine. The highest bond strength was found in Group 1 (Endosequence) (P strength was found in Group 2 (MTA Fill apex). Statistical analysis is done by two-way ANOVA and Newman-Keuls multiple post hoc. The push-out bond strength of Bioceramic sealer was highest followed by resin-based sealer and lowest bond strength was observed in MTA-based sealer.

  4. To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment.

    Science.gov (United States)

    Shivanand, Sunita; Patil, Chetan R; Thangala, Venugopal; Kumar, Pabbati Ravi; Sachdeva, Jyoti; Krishna, Akash

    2013-05-01

    To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment. Sixty extracted premolars were retreated with following systems: Group -ProTaper Universal retreatment files, Group 2-ProFile system, Group 3-H-file. Specimens were split longitudinally and amount of remaining gutta-percha on the canal walls was assessed using direct visual scoring with the aid of stereomicroscope. Results were statistically analyzed using ANOVA test. Completely clean root canal walls were not achieved with any of the techniques investigated. However, all three systems proved to be effective for gutta-percha removal. Significant difference was found between ProTaper universal retreatment file and H-file, and also between ProFile and H-file. Under the conditions of the present study, ProTaper Universal retreatment files left significantly less guttapercha and sealer than ProFile and H-file. Rotary systems in combination with gutta-percha solvents can perform superiorly as compared to the time tested traditional hand instrumentation in root canal retreatment.

  5. Comparison of efficiency of the retreatment procedure between Wave One Gold and Wave One systems by Micro-CT and confocal microscopy: an in vitro study.

    Science.gov (United States)

    Canali, Lyz Cristina Furquim; Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Bramante, Clovis Monteiro; Só, Marcus Vinícius Reis; Duarte, Marco Antonio Hungaro

    2018-04-19

    To compare, by Micro-CT and confocal laser scanning microscopy (CLSM), the ability of the Wave One Gold and Wave One systems to remove filling material from mesial canals of mandibular molars, effective time spent; quantity of extruded material, and percentage of sealer in the dentinal tubules after retreatment and re-obturation procedures. Ten first mandibular molars (n = 20 mesial canals) were prepared and filled with gutta-percha and Endofill sealer mixed with Rhodamine B dye using the single cone technique. After 7 days, the canals were scanned using a high-definition micro-computer tomography with 19-mm voxel size and divided into two groups (n = 10) according to the system used in retreatment: group 1, Wave One (WO), and group 2, Wave One Gold (WG). After removing filling material with the primary file of each system, the WO 40/.08 and WG 35/.06 files were used. After using each file, a new scanning was performed and the residual filling material and extruded filling material were measured. The effective time spent to remove the canal filling was measured after each instrument. After retreatment, the teeth were re-obturated with gutta-percha and AH Plus sealer mixed with fluorescein dye using the single-cone technique. The roots were sectioned at 2, 4 and 6 mm and analysed by CLSM to measure the percentage of remaining sealer and the sealer of the new root canal filling. The data were statistically compared (P  0.05). When using WO 25, the operator spent significantly less effective time than when using WG 25 (P  0.05). Neither of the two systems removed all the filling material. The WG system presented similar ability in removing filling and extruded material in comparison with WO system. The effective time spent was shorter for WO 25 than for WG 25. Wave One Gold can be an alternative to perform retreatment considering that in comparison with Wave One, there was no difference in filling material removal capacity and extruded materials

  6. Apeksifikasi dengan mineral trioxide aggregate dan perawatan intracoronal bleaching pada gigi insisivus sentralis kiri maksila non vital diskolorasi

    Directory of Open Access Journals (Sweden)

    I. Inajati

    2016-08-01

    Full Text Available Affecification with mineral trioxide aggregate and care of intracoronal bleaching on the non vital discoloration maxillary left central incisor. Maxillary anterior teeth in children and adults often experience trauma. This later makes the dental pulp roots that are not completely formed face the necrosis and apical closure stop later causing the apex wide and open. The opened apex can be coped with the care of affecification. Mineral Trioxide Aggregate (MTA is the best material of affecification used for the formation of apical barrier. The purpose of this case report was to report the achievement of the apical sealing using MTA in the non-vital permanent maxillary left central incisor with the opened apical due to the trauma. The complaints of male patients aged 20 years was about the broken and discoloured left upper front teeth and becomes a traumatic event since the age of 10 years due to a fall and hit the cement floor. A clinical examination of non-vital teeth used the fracture Ellis IV class with wide open apex and discoloration. The radiographic image showed a widely opened apex with large root canal and there was a periapical radiolucency. The treatment given was affecification with MTA followed obturation with gutta-percha and sealer AH 26. In the following week it was continued with intracoronal bleaching with the application of sodium perborate and 30% hydrogen peroxide. Before treatment, the teeth were brownish (C4 and after treatment it turned into yellowish white (B2. A week after the bleaching treatment was completed and the installation of fibre post was done, followed by giving the composite resin restorations class IV cavity. The 2-week control later showed no abnormalities. In conclusion, the affecification treatment with MTA can accelerate treatment with the formation of apical barrier that stimulates the healing and may be followed by obturation with guttap percha followed by doing intracoronal bleaching and final

  7. Maxillary obturator

    Directory of Open Access Journals (Sweden)

    Aruna Jawahirlal Bhandari

    2017-01-01

    Full Text Available Defects in the maxillary jaw can be congenital, developmental, acquired, traumatic or surgical involving the oral cavity and related anatomic structure. Absence or loss of some or all of the soft palate and / or hard palate results in insufficient structure or altered function of the remaining tissues. Defects can cause disruption of articulation and airflow during speech production and also nasal reflux during deglutition. Patients after surgical resection have altered anatomy due to scaring, tissue contracture, lack of bony support and tissue edema. These patients have problem of regurgitation of water and food through nose and difficulty in speech. These changes require the fabrication of prosthesis and also sometimes repeated prosthesis adjustments to confirm to the soft tissue changes. To prevent this and to help the patient in deglutition and speech defects must be restored with prosthesis. In such situation an obturator is designed to close the opening between the residual hard and / or soft palate and the pharynx. The prosthesis provided for these patients are called as obturators. An obturator is a prosthesis which is fabricated for the patients with the palatal defects in the form of cleft lip and palate, oroantral fistula or surgical resection after removable of pathology like tumor or cancer. This review article will highlight on the Prosthetic Rehabilitation of the maxillary defects and the types of obturators.

  8. Postoperative pain after endodontic retreatment: single- versus two-visit treatment.

    Science.gov (United States)

    Yoldas, Oguz; Topuz, Aysin; Isçi, A Sehnaz; Oztunc, Haluk

    2004-10-01

    The purpose of this clinical study was to determine the effect of 1- or 2-visit root canal treatment on the postoperative pain in the retreatment cases. Two hundred eighteen cases that required retreatment were included in the study. Obturated and unfilled canal space and the status of periapical tissues were evaluated according to the PAI index. The patients were subcategorized in regard to the presence or the absence of preoperative pain. Approximately half of each category was treated in 1 appointment. After removing the previous root canal obturation materials and biomechanic preparation of root canals, the teeth in the 1-visit group were obturated at the first appointment by using AH 26 sealer and laterally compacted gutta-percha, and those in the 2-visit group were medicated with calcium hydroxide-chlorhexidine combination and then closed with a temporary filling material. One week after the initial appointment, patients were asked about the occurrence of postoperative pain. The level of discomfort was rated as no pain, mild pain, moderate pain, or severe pain (flare-up). Data were statistically analyzed using the chi-squared and Fischer exact tests. Eight patients from the 1-visit group and 2 patients from the 2-visit group had flare-ups. There was a statistical difference between the groups (P endodontic treatment with intracanal medication was found to be effective in reducing postoperative pain of previously symptomatic teeth and decreased the number of flare-ups in all retreatment cases.

  9. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    International Nuclear Information System (INIS)

    Antonijevic, Djordje; Milovanovic, Petar; Brajkovic, Denis; Ilic, Dragan; Hahn, Michael; Amling, Michael; Rakocevic, Zlatko; Djuric, Marija; Busse, Björn

    2015-01-01

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  10. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Antonijevic, Djordje; Milovanovic, Petar [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Brajkovic, Denis [Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac (Serbia); Ilic, Dragan [Department of Restorative Medicine, School of Dental Medicine, University of Belgrade, Belgrade (Serbia); Hahn, Michael; Amling, Michael [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany); Rakocevic, Zlatko [Laboratory for Atomic Physics, Institute for Nuclear Science “Vinca”, University of Belgrade, Belgrade (Serbia); Djuric, Marija [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Busse, Björn, E-mail: b.busse@uke.uni-hamburg.de [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany)

    2015-11-15

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  11. USAGE OF PASTE FOR TEMPORARY PLACEMENT IN THE TREATMENT OF CHRONIC APICAL PERIODONTITIS

    Directory of Open Access Journals (Sweden)

    A.V. Borysenko

    2012-03-01

    Full Text Available Summary: The aim of the present investigation was usage of medicamental paste with antibacterial and regeneration action for temporary placement in the treatment of chronic apical periodontitis. Materials and method: The medicamental paste for temporary placement of root canals consists of a mixture of metronidazole, Enterosgel (Silm and Alflutop (Biotehnos S.A., Romania. Thë paste was used for the treatment of 30 teeth with chronic apical periodontitis. Final obturation of the root canals was performed with gutta percha cones and sealer. The efficiency of the treatment was appreciated after examination on the basis of clinical and radiographic findings. Results: During the treatment of the 30 teeth, no exacerbations of the pathological process were recorded. Pain after obturation of the root canals was revealed in only 6 (20% of the treated teeth. No pain, pathologic changes of gingiva, good mastication efficiency in all teeth after treatment were revealed. Conclusions: The high clinical efficiency of the medicamental paste with antibacterial and regeneration action at the level of temporary root canals placement in the treatment of chronic apical periodontitis was shown. Keywords: chronic apical periodontitis, medicamental paste for temporary root canals placement, metronidazole, Enterosgel (Silm and Alflutop (Biotehnos S.A., Romania

  12. Apical sealing ability of two novel root canal sealers: An ex-vivo study

    Directory of Open Access Journals (Sweden)

    Priyanka Setia

    2013-01-01

    Full Text Available Objective: The objective was to compare the sealing ability of two root canal sealers viz.: Hybrid Root SEAL (Sun Medical, Tokyo, Japan and iRoot SP (Innovative BioCeramix Inc., Vancouver, Canada. Materials and Methods: A sample of 60 permanent single rooted, human maxillary central incisors of similar sizes was selected for the study. The teeth were decoronated and randomly divided into two groups viz.: Group A and Group B, comprising of thirty teeth each. In Group A, Hybrid Root SEAL and Group B, iRoot SP were used as root canal sealers along with Gutta-percha cones using lateral condensation technique to obturate the canals. After obturation roots were covered with nail paint except 2.0 mm of root and stored in 0.5% methylene blue dye for 1 week. The teeth were immersed in 10 ml of 65% nitric acid for complete dissolution and subsequently subjected to UV spectrophotometer to quantify the concentration of the dye in each sample. The data were analyzed using the unpaired t-test. Results: The mean dye leakage value in Group B (0.368 was less as compared to Group A (0.408. However, statistically the difference was nonsignificant (P = 0.053. Conclusion: There was no statistically significant difference among the two groups.

  13. Outcome of endodontic treatment of teeth filled using lateral condensation versus vertical compaction (Schilder's technique).

    Science.gov (United States)

    Aqrabawi, Jamal A

    2006-02-15

    The purpose of this prospective clinical and radiographic investigation was to assess the treatment results following endodontic therapy of teeth filled with lateral condensation versus teeth filled with vertical compaction of warm gutta-percha. A total of 290 patients were treated using the standardized step-back technique for canal preparation, which were filled with either lateral condensation or vertical compaction in one single session. Five years later, the treatment results were assessed clinically and radiographically and related to the type of the obturation technique using Chi-square analysis. Of the 340 teeth that were reexamined, 160 teeth were filled with lateral condensation, and 180 teeth were filled with vertical condensation. The results showed a significantly higher success rate for the vertical compaction versus the lateral condensation technique of teeth presented with preoperative periapical lesions P<0.04. Regardless of the preoperative periapical status of the teeth, no statistically significant difference was found between the two techniques. The overall success rate of both filling techniques was 80.3%.

  14. 3-D diagnosis-assisted management of anomalous mandibular molar

    Directory of Open Access Journals (Sweden)

    Neelam Mittal

    2012-01-01

    Full Text Available This case report describes the successful non-surgical endodontic management of carious exposed three-rooted mandibular molar with four root canals detected on the pre-operative radiograph taken with 20 degrees mesial angulation and confirmed with a 64-slice helical computed tomography scan-assisted 3-D-reconstructed images. Access cavity shape was modified to locate the extra canal with respect to the distolingual root in the left mandibular first molar. Copious irrigation was accomplished with 5.25% sodium hypochlorite and 17% EDTA. Biomechanical preparation was done using protapers. Calcium hydroxide dressing was done for 1 week. The tooth was obturated using gutta percha and AH 26 root canal sealer, and it was permanently restored with composite. Clinical examination on follow-up visits revealed no sensitivity to percussion and palpation in the left mandibular first molar. Thorough knowledge of root canal variations and use of advanced diagnostic modalities lead to successful non-surgical management of the complex cases.

  15. Two-piece hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Subramaniam Elangovan

    2011-01-01

    Full Text Available There are various types of obturator fabrication achievable by prosthodontist. Maxillectomy, which is a term used by head and neck surgeons and prosthodontists to describe the partial or total removal of the maxilla in patients suffering from benign or malignant neoplasms is a defect for which to provide an effective obturator is a difficult task for the maxillofacial prosthodontist. Multidisciplinary treatment planning is essential to achieve adequate retention and function for the prosthesis. Speech is often unintelligible as a result of the marked defects in articulation and nasal resonance. This paper describes how to achieve the goal for esthetics and phonetics and also describes the fabrication of a hollow obturator by two piece method, which is simple and maybe used as definitive obturator for maximum comfort of the patient.

  16. Predictors of obturator functioning and satisfaction in Turkish patients using an obturator prosthesis after maxillectomy.

    Science.gov (United States)

    Ozdemir-Karatas, Meltem; Balik, Ali; Evlioglu, Gülümser; Uysal, Ömer; Peker, Kadriye

    2018-03-01

    The aim of this study was to determine the sociodemographic, behavioral, and clinical factors affecting obturator function and satisfaction using the obturator functioning scale (OFS) in maxillectomy patients rehabilitated with obturator prostheses. The study sample consisted of 41 maxillectomy patients. The OFS was translated into Turkish and adapted for assessing obturator functioning and patient satisfaction among Turkish patients. Data were collected from patients' medical records and self-completed questionnaires, including the Turkish version of the OFS, sociodemographic and behavioral characteristics. Descriptive statistics, Mann-Whitney U test, Spearman's correlation coefficient, and backward stepwise multiple linear regression were used for data analysis. Internal consistency (Cronbach's alpha = 0.85) and test-retest reliability (intraclass correlation coefficient = 0.86) were acceptable for the OFS. The most frequently reported problem was "difficulty chewing." Bivariate analysis revealed significant differences in total OFS scores in terms of surgery type, defect size, and education level, except for the other clinical and sociodemographic characteristics and behavioral factors. Education level and surgery type were found to be the most important predictors of patient satisfaction and functioning of the obturator. The Turkish version of the OFS might be a useful tool for clinicians to identify patients who are at risk for poor functioning of the obturator, lack of satisfaction, and unmet needs. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study.

    Science.gov (United States)

    Yilmaz, Ayca; Helvacioglu-Yigit, Dilek; Gur, Cansu; Ersev, Handan; Kiziltas Sendur, Gullu; Avcu, Egemen; Baydemir, Canan; Abbott, Paul Vincent

    2017-01-01

    The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9  μ m resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR) or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  18. The Effect of Changing Focal Trough in a Panoramic Device on the Accuracy of Distance Measurements

    Directory of Open Access Journals (Sweden)

    Mehrdad Abdinian

    2018-01-01

    Full Text Available >Introduction: Magnification and distortion are the most important limitations of panoramic radiography. The aim of this study was to determine the effects of changing focal trough option of Planmeca SCARA 3 on the accuracy of linear distance measurements.Materials and Methods: In this in-vitro study, 28 pieces of gutta-percha were attached to the assumptive place of each lost root of an adult dry skull with average size and normal shape. The actual measurements were obtained by a digital caliper. The panoramic images of the skull were taken in six different sizes and shapes of focal trough. This procedure was repeated ten times with new gutta-percha. Paired t-test was used to compare the values of different actual and radiographic images of gutta-percha dimensions.Results: The mean difference [standard deviation (SD] between actual measurement and panoramic radiography in the different groups was from 0.37 (1.1 to 0.58 (2.87 mm. The mean (SD difference of linear measurements between real and radiographic images was 0.52 (0.43 mm in average size, V-shaped group, which was statistically and clinically significant (P = 0.00.Conclusion: Changing the focal trough option of Planmeca SCARA 3 has minimal effects on the accuracy of linear measurements in panoramic radiographs.

  19. A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

    Energy Technology Data Exchange (ETDEWEB)

    Haghanifar, Sina; Moudi, Ehsan; Mesgarani, Abbas; Abbaszadeh, Naghi [Dental Material Research Center, Dental Faculty, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of); Bijani, Ali [Non-Communicable Pediatric Diseases Research Center, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of)

    2014-06-15

    The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root perforations of mandibular molars. In this in vitro study, 48 mandibular molars were divided into 4 groups. First, the mesial canals of all the 48 teeth were endodontically prepared. In 2 groups (24 teeth each), the roots were axially perforated in the mesiolingual canal 1-3 mm below the furcation region, penetrating the root surface ({sup r}oot perforation{sup )}. Then, in one of these 2 groups, the mesial canals were filled with gutta-percha and AH26 sealer. Mesial canals in one of the other 2 groups without perforation (control groups) were filled with the same materials. The CBCT and periapical radiographs with 3 different angulations were evaluated by 2 oral and maxillofacial radiologists. The specificity and sensitivity of the two methods were calculated, and P<0.05 was considered significant. The sensitivity and specificity of CBCT scans in the detection of obturated root canal perforations were 79% and 96%, respectively, and in the case of three-angled periapical radiographs, they were 92% and 100%, respectively. In non-obturated root canals, the sensitivity and specificity of CBCT scans in perforation detection were 92% and 100%, respectively, and for three-angled periapical radiographs, they were 50% and 96%, respectively. For perforation detection in filled-root canals, periapical radiography with three different horizontal angulations would be trustworthy, but it is recommended that CBCT be used for perforation detection before obturating root canals.

  20. Effectiveness of EDTA as the irrigation solution to remove smear layer in root canal

    Directory of Open Access Journals (Sweden)

    Kurniasri Amas Achiar

    2009-07-01

    Full Text Available One of the objectives of successful endodontic treatment is the hermetic obturation of the root canal system. To achieve this, the root canal filling must seal the canal space both apically and coronally to prevent the ingress of microorganisms or tissue fluids into the canal space. Apical leakage is reported a common reason for the clinical failure of endodontic therapy. Leakage through an obturated root canal is expected to take place at interfaces between sealer and dentin or sealer and gutta-percha, or through voids within the sealer. Hence, the sealing quality of root canal filling depends much on the sealing ability of the sealer. Therefore, anything that may influence the adaptation of the root filling to the canal wall is can determine the degree and the extent of leakage, and ultimately the prognosis of the endodontic therapy. In endodontic therapy, the smear layer formation results from root canal preparation and may influence the effective seal of the root canal system. The smear layer formation is mainly composed of inorganic components (dentin debris and organic materials, such as pulp tissue remnant, bacteria, and blood cells. Removal of the smear layer from the root canal walls before the obturation can reduce the leakage of root canal sealer. To remove the smear layer use 10 ml 17% EDTA followed by 10 ml of 5.25% NaOCl as irrigating solution. This paper discribe about how the effectivity of EDTA as irigating solution to remove the smear layer especially in the apical root canal with many lateral canal to reduce the apical leakage.

  1. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study

    Directory of Open Access Journals (Sweden)

    Ayca Yilmaz

    2017-01-01

    Full Text Available The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9 μm resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  2. Guided Modern Endodontic Surgery: A Novel Approach for Guided Osteotomy and Root Resection.

    Science.gov (United States)

    Strbac, Georg D; Schnappauf, Albrecht; Giannis, Katharina; Moritz, Andreas; Ulm, Christian

    2017-03-01

    Continuous improvements in techniques, instruments, and materials have established modern endodontic microsurgery as a state-of-the-art treatment method. The purpose of this approach was to introduce a new surgical endodontic technique by using a three-dimensional printed template for guided osteotomy and root resection. A 38-year-old patient was diagnosed with periapical lesions of teeth #3 and #4 and extruded gutta-percha material. Three-dimensional radiographic and optical scan files were imported into surgical planning software designed for guided implant surgery. Within the adapted software program the periapical lesions and the extruded gutta-percha were visualized and marked. With the aid of virtually positioned surgical pins and piezoelectric instruments, the osteotomy size, the apical resection level, and the bevel angle were defined before treatment. Three-dimensional surgical templates for each tooth were designed within the software program for a guided treatment approach. This approach comprised the treatment of periapical lesions of teeth #3 and #4 with root-end fillings and the detection and complete removal of the extruded gutta-percha material without perforation of sinus membrane. There were no postoperative complications, and clinical and radiologic assessments verified complete healing of the teeth. The guided microsurgical endodontic treatment presented appears to be a viable technique that allows for predefined osteotomies and root resections. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Palatal obturators in patients after maxillectomy.

    Science.gov (United States)

    Cardelli, P; Bigelli, E; Vertucci, V; Balestra, F; Montani, M; DE Carli, S; Arcuri, C

    2014-01-01

    Prosthodontic management of palatal defects is fundamental to improve patient's life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators.

  4. Endodontic management of C-shaped root canal system of mandibular first molar by using a modified technique of self-adjusting file system.

    Science.gov (United States)

    Helvacioglu-Yigit, Dilek

    2015-01-01

    C-shaped canal system is a seldom-found root canal anatomy which displays a challenge in all stages of endodontic treatment. According to the literature, this type of canal morphology is not a common finding in the mandibular first molar teeth. This case report presents endodontic management of a mandibular first molar with a C-shaped canal system. Root canal system was cleaned and shaped by nickel-titanium (NiTi) rotary instruments combined with self-adjusting file (SAF). Obturation was performed using warm, vertical condensation combined with the injection of warm gutta-percha. Follow-up examination 12 months later showed that the tooth was asymptomatic. The radiological findings presented no signs of periapical pathology. The clinician must be aware of the occurence and complexity of C-shaped canals in mandibular first molar teeth to perform a successful root canal treatment. The supplementary use of SAF after application of rotary instruments in C-shaped root canals might be a promising approach in endodontic treatment of this type of canal morphology.

  5. Endodontic management of a mandibular second molar with radix entomolaris: a case report

    Directory of Open Access Journals (Sweden)

    Rosaline Hannah

    2014-05-01

    Full Text Available The presence of radix entomolaris (RE in a mandibular first molar is a common occurrence in certain ethnic groups, but the presence of RE in a mandibular second molar is a rare occurrence. In the present case, RE was identified from preoperative radiographs and confirmed using cone-beam computed tomography (CBCT. The access cavity was modified to locate the RE. Cleaning and shaping were performed with nickel-titanium rotary instruments. Obturation was completed with gutta-percha cones using AH Plus (Dentsply Detrey GmbH as sealer. From the CBCT axial images, the RE was determined to have a Type III curvature by the De Moor classification, Type B separate RE by the Carlsen and Alexandersen classification, and radiographically, a Type i image by the Wang classification. The presence of RE in the mandibular second molar makes it essential to anticipate and treat the distolingual root canal. This case report highlights the usefulness of CBCT for assessing RE in the mandibular second molar, which can help the clinician in making a confirmatory diagnosis and assessing the morphology of the root canal.

  6. Comparison of Vibringe, EndoActivator, and needle irrigation on sealer penetration in extracted human teeth.

    Science.gov (United States)

    Bolles, Jordan A; He, Jianing; Svoboda, Kathy K H; Schneiderman, Emet; Glickman, Gerald N

    2013-05-01

    Vibringe is a new device that allows continuous sonic irrigation of the canal system during endodontic treatment. The aim of this study was to compare the effect of different irrigation systems on sealer penetration into dentinal tubules of extracted single-rooted teeth. Fifty single-rooted human teeth were instrumented and randomly divided into 4 groups: group 1 (control), saline; group 2 (conventional irrigation), 17% EDTA followed by 6% NaOCl; group 3 (EndoActivator), same irrigants as group 2; group 4 (Vibringe), same irrigants as group 2. Obturation of all teeth was done with gutta-percha and SimpliSeal labeled with fluorescent dye. Transverse sections at 1 mm and 5 mm from the root apex were examined by using confocal laser scanning microscopy. Percentage and maximum depth of sealer penetration were measured by using NIS-Elements Br 3.0 imaging software. Groups 3 and 4 had a significantly greater percentage of the canal wall penetrated by sealer at the 5-mm level than group 1 (P irrigation. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Regenerative endodontics--Creating new horizons.

    Science.gov (United States)

    Dhillon, Harnoor; Kaushik, Mamta; Sharma, Roshni

    2016-05-01

    Trauma to the dental pulp, physical or microbiologic, can lead to inflammation of the pulp followed by necrosis. The current treatment modality for such cases is non-surgical root canal treatment. The damaged tissue is extirpated and the root canal system prepared. It is then obturated with an inert material such a gutta percha. In spite of advances in techniques and materials, 10%-15% of the cases may end in failure of treatment. Regenerative endodontics combines principles of endodontics, cell biology, and tissue engineering to provide an ideal treatment for inflamed and necrotic pulp. It utilizes mesenchymal stem cells, growth factors, and organ tissue culture to provide treatment. Potential treatment modalities include induction of blood clot for pulp revascularization, scaffold aided regeneration, and pulp implantation. Although in its infancy, successful treatment of damaged pulp tissue has been performed using principles of regenerative endodontics. This field is dynamic and exciting with the ability to shape the future of endodontics. This article highlights the fundamental concepts, protocol for treatment, and possible avenues for research in regenerative endodontics. © 2015 Wiley Periodicals, Inc.

  8. Successful Ultra-Conservative Management of a Mandibular Premolar with Dens Invaginatus.

    Science.gov (United States)

    Abazarpour, Ramin; Parirokh, Masoud; Farhadi, Aida; Jalali, Zahra; Kheirabadi, Nasir

    2017-01-01

    Dens invaginatus is one of the most common anomalies of tooth structure. It is caused by the invagination of the crown surface during odontogenesis that enters the pulp chamber of the affected tooth. Depending on the complexity of invagination, the tooth might present with pulp necrosis, open apex and a complicated root canal system. This case report presents an Oehlers' type 2 dens-invaginatus in a mandibular premolar with chronic apical abscess. In most cases, dens invaginatus is removed during treatment. However, in this case report, based on cone-beam computed tomography (CBCT) evaluation, non-surgical treatment and maintenance of the invaginated segment was chosen in order to prevent compromising the tooth structure and its susceptibility to future root fracture. This is a new treatment approach and has not been performed in previous reports. Calcium-enriched mixture (CEM) cement was used as an apical plug followed by gutta-percha in warm vertical compaction for root canal obturation. The case was followed up for 36 months after treatment. This report highlights the importance of selecting the appropriate treatment approach based on CBCT evaluation.

  9. Bio-reconstruction of root canal using dentin post

    Directory of Open Access Journals (Sweden)

    Navin Mishra

    2013-01-01

    Full Text Available This case report describes the successful management of complicated crown fracture of left maxillary central incisor (#21 of 23-year-old male using dentin (biological post made from human tooth. Endodontic treatment was initiated and sectional obturation was done using ProTaper gutta-percha and AH Plus sealer. The coronal space was modified to receive a human dentin post. A two-step procedure comprising direct and indirect technique of post fabrication was done to achieve the accuracy of biological post. A maxillary cuspid from an institutional tooth bank was taken, sectioned mesiodistally using a diamond disc simulating the length and thickness of mock post. Dentin post was first verified on the plaster model and then cemented in tooth #21. Core build up was done with composite and porcelain fused to metal (PFM crown was luted. On the follow-up visits, patient was asymptomatic and radiographic evaluation revealed normal periradicular architecture. Biological posts may be good alternatives to conventional post systems as they preserve internal dentin walls, provide excellent adhesion, and resilience similar to natural tooth structure.

  10. Use of cone-beam computed tomography and three-dimensional modeling for assessment of anomalous pulp canal configuration: a case report

    Directory of Open Access Journals (Sweden)

    Alper Sinanoglu

    2015-05-01

    Full Text Available Three-dimensional (3D reconstruction of cone-beam computed tomography (CBCT scans appears to be a valuable method for assessing pulp canal configuration. The aim of this report is to describe endodontic treatment of a mandibular second premolar with aberrant pulp canal morphology detected by CBCT and confirmed by 3D modeling. An accessory canal was suspected during endodontic treatment of the mandibular left second premolar in a 21 year old woman with a chief complaint of pulsating pain. Axial cross-sectional CBCT scans revealed that the pulp canal divided into mesiobuccal, lingual, and buccal canals in the middle third and ended as four separate foramina. 3D modeling confirmed the anomalous configuration of the fused root with a deep lingual groove. Endodontic treatment of the tooth was completed in two appointments. The root canals were obturated using lateral compaction of gutta-percha and root canal sealer. The tooth remained asymptomatic and did not develop periapical pathology until 12 months postoperatively. CBCT and 3D modeling enable preoperative evaluation of aberrant root canal systems and facilitate endodontic treatment.

  11. Herniography off femoral, obturator and perineal hernias

    International Nuclear Information System (INIS)

    Ekberg, O.; Nordblom, I.; Fork, F.T.; Gullmo, A.

    1985-01-01

    Positive contrast herniography was used in the workup of 550 patients with unclear groin pain. The majority of these patients had rather characteristic hernias of indirect, direct or femoral type. However, now and then diagnostic problems arose. A femoral hernia may look like a direct or even obturator hernia. There is also a variety of multilocular femoral hernias and other types. A femoral hernia may be present together with other hernias in the ipsilateral or contralateral groin. Obturator hernias are usually small but are always confined to the obturator canal laterally in the obturator foramen. Abnormalities in the pouch of Douglas may include a deep rectogenital pouch, diverticula and true herniations. These uncommon herniographic findings are described and discussed. (orig.) [de

  12. Obturator externus was larger, while obturator internus size was similar in ballet dancers compared to nondancing athletes.

    Science.gov (United States)

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Cook, Jill

    2018-06-02

    To compare the cross-sectional area (CSA) of hip external rotators, obturator externus (OE) and obturator internus (OI), in ballet dancers and nondancing athletes, and evaluate the relationship between obturator muscle size and hip pain. Case-control study. Elite ballet and sport. 33 male and female professional ballet dancers and 33 age and sex-matched athletes. CSA's of OE and OI measured on magnetic resonance imaging (MRI) of one hip. Hip pain was scored with the Copenhagen Hip and Groin Outcome Score (HAGOS): HAGOS pain score of 100 was defined as no pain and a score less than 100 was defined as pain. Participants weight and height. Estimated marginal mean CSA of OE was 14% larger in dancers than athletes (p = 0.01, ηp2 = 0.1); the size of OI was similar (p > 0.05). Men and women in both groups had similar sized OI and OE. There was no interaction between the estimated marginal mean CSA of either obturator and hip pain. It appears that ballet selectively increases muscle size of OE, but not OI. Obturator size was not related to mild hip pain, as OE and OI size was similar in dancers and athletes with and without pain. Copyright © 2018. Published by Elsevier Ltd.

  13. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin

    Directory of Open Access Journals (Sweden)

    Jorge Henrique Stefaneli Marques

    2018-03-01

    Full Text Available Abstract: The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10: MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80 was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01. MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  14. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin.

    Science.gov (United States)

    Stefaneli Marques, Jorge Henrique; Silva-Sousa, Yara Teresinha Corrêa; Rached-Júnior, Fuad Jacob Abi; Macedo, Luciana Martins Domingues de; Mazzi-Chaves, Jardel Francisco; Camilleri, Josette; Sousa-Neto, Manoel Damião

    2018-03-08

    The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  15. Obturator foramen dissection for excision of symptomatic transobturator mesh.

    Science.gov (United States)

    Reynolds, W Stuart; Kit, Laura Chang; Kaufman, Melissa R; Karram, Mickey; Bales, Gregory T; Dmochowski, Roger R

    2012-05-01

    Groin pain after transobturator synthetic mesh placement can be recalcitrant to conservative therapy and ultimately requires surgical excision. We describe our experiences with and technique of obturator foramen dissection for mesh excision. The records of 8 patients treated from 2005 to 2010, were reviewed. Obturator dissection was performed via a lateral groin incision over the inferior pubic ramus at the level of the obturator foramen, typically in conjunction with orthopedic surgery. Five patients had transobturator mid urethral sling surgery for stress urinary incontinence, 2 had mid urethral sling and trocar based anterior vaginal wall mesh kits with transobturator passage of mesh arms for stress urinary incontinence and pelvic organ prolapse, and 1 had an anterior vaginal wall mesh kit for pelvic organ prolapse. Patients had 0 to 2 prior transvaginal mesh excisions before obturator surgery. All patients presented with intractable pain in the area of the obturator foramen and/or medial groin for which conservative treatment measures had failed. Six patients underwent concurrent vaginal and obturator dissection and 2 underwent obturator dissection alone. In all cases residual mesh (3 to 11 cm) was identified and excised from the obturator foramen. Mesh was closely associated to or traversing the adductor longus muscle and tendon with significant fibrous reaction in all cases. Postoperatively 5 patients were cured of pain and/or infection, and 3 reported no or some improvement at a mean followup of 6 months (range 1 to 12). Our experience suggests that surgical excision of residual mesh can alleviate many of the symptoms in many patients. In all cases mesh remnants were identified and removed, and typically involved neuromuscular structures adjacent to the obturator foramen. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. The Effect of Calcium Hydroxide As an Intracanal Medication of The Apical Microleakage

    Directory of Open Access Journals (Sweden)

    Heshmat Mohajer AR

    2011-12-01

    Full Text Available Background and Aims: Nowadays, calcium hydroxide is used as a dressing for canal sterilization and repair progression of apical lesions. The aim of this study was to investigate the effect of calcium hydroxide as an intracanal medicament on the apical microleakage of root filling.Materials and Methods: In this experimental study, 46 extracted single-rooted human teeth were instrumented with step-back technique to master apical file (MAF size 35. Specimens were randomly divided into 2 groups (n = 20. In group 1, the specimens were treated with calcium hydroxide intracanal medication; and in group 2, the samples did not receive any medication. The teeth were incubated in 100% humidity at 37°C for one week. After that, calcium hydroxide was removed using irrigation with normal saline and reaming with MAF. The root canals were obturated with gutta- percha and AH26 sealer using lateral compaction technique. Specimens were incubated in 100% humility at 37°C for 72 hours and then immersed in India ink for 1 week. Finally, the teeth were cleared and the maximum linear dye penetration was measured under a stereomicroscope at 4X magnification. The data were analyzed by T-test and Chi-square.Results: There was no significant difference between the two experimental groups (P=0.068. Conclusion: The findings of this study indicated that using calcium hydroxide as an intracanal medicament did not influence the apical microleakage after final obturation of the root canal system.

  17. Lacplesa Alus, Gutta bought by Nordic investors

    Index Scriptorium Estoniae

    2004-01-01

    The danish Brewery Group ostis enamuse Läti õlletehase Lacplesa Alus aktsiatest, Lätis registreeritud Islandi kapitaliga firma Nordic Partners ostis mahlatootja Gutta. Lisa: Läti kaubamärgid, mis müüdud 2004. a.

  18. MR Imaging Features of Obturator Internus Bursa of the Hip

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Jong Oh

    2008-01-01

    The authors report two cases with distension of the obturator internus bursa identified on MR images, and describe the location and characteristic features of obturator internus bursitis; the 'boomerang'-shaped fluid distension between the obturator internus tendon and the posterior grooved surface of the ischium

  19. Obturator Definitive Mandibula Post Hemimandibulectomy Sinistra

    Directory of Open Access Journals (Sweden)

    Paul Sugiyo

    2012-12-01

    Full Text Available Latar Belakang. Operasi bedah pemotongan mandibula pada kasus tumor jinak maupun tumor ganas dapat menyebabkan deviasi mandibula. Tindakan perawatan bedah tergantung pada lokasi dan perluasan tumor mandibula, tindakan perawatan bedah tersebut meliputi bedah marginal, segmental, hemimandibulectomy, dan total mandibulectomy. Tujuan. Makalah ini menjelaskan tentang perawatan rehabilitasi dengan obturator definitive mandibula. Para klinisi harus menunggu masa penyembuhan yang sempurna sebelum disarankan untuk dibuatkan onturator definitive mandibula. Sejak awal penyembuhan diperlukan intervensi prostodontis untuk mencegah deviasi mandibula. Protesa ini membantu pergerakan mandibula secara normal tanpa terjadi penyimpangan pada fungsi bicara dan pengunyahan. Laporan Kasus. Pada bulan Maret 2012, pasien laki-laki, berumur 46 tahun datang ke RSGM Bagian Prostodonsia atas rujukan dari RS. Dr. Sardjito Bagian Bedah Mulut setelah dilakukan operasi tumor ameloblastoma mandibula sinistra (post hemimandibulectomy mandibula sinistra dengan pemasangan plat rekonstruksi tiga bulan sebelumnya untuk dibuatkan obturator definitive mandibula. Pasien mengeluh bibir bawah sebelah kiri sering tergigit, fungsi bicara, fungsi pengunyahan, dan penampilannya terganggu. Hasil. Setelah dilakukan perawatan dengan memakai obturator definitive mandibula dalam kurun waktu 8 bulan, hingga saat ini hasil perawatan ini dapat mengembalikan fungsi bicara, fungsi pengunyahan, dan fungsi estetik sehingga pasien merasa lebih nyaman dan percaya diri. Kesimpulan. Deviasi mandibula setelah operasi hemimandibulectomy diatasi dengan bedah rekonstruksi menggunakan plat rekonstruksi, kemudian segera setelah penyembuhan perlu melibatkan prostodontis untuk pemasangan obturator definitive mandibula.    Background. Surgical restion of the mandible due to presence of benign or malignant tumor is the common cause of the mandibular deviation. Depending upon the location and extent of the tumor in

  20. MR Imaging Features of Obturator Internus Bursa of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Jong Oh [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2008-08-15

    The authors report two cases with distension of the obturator internus bursa identified on MR images, and describe the location and characteristic features of obturator internus bursitis; the 'boomerang'-shaped fluid distension between the obturator internus tendon and the posterior grooved surface of the ischium

  1. Innovations in endodontic filling materials: guttapercha vs Resilon.

    Science.gov (United States)

    de Souza Filho, Francisco José; Gallina, Giuseppe; Gallottini, Livio; Russo, Riccardo; Cumbo, Enzo Maria

    2012-01-01

    One of the goals of endodontic treatment is to achieve a complete, tridimensional, hermetic sealing of the root canal system to prevent the entry of microorganisms or their products through both the coronal and apical pathways. Gutta-percha is the most widely used material for root canal filling and despite its numerous properties, such as biocompatibility and thermoplasticity, it has however an important limit: the lack of adhesion to the canal walls. Attempts to address this problem have been made over the years by using endodontic cements capable of bonding to canal dentine but their tendency to resorption in time can compromise the quality of treatment. The first step towards a real adhesive endodontic filling(4) is rather recent; in fact, it goes back to 2003 when, on the occasion of the American Dental Association (ADA) Annual Session, Resilon Research LLC introduced a new canal filling adhesive system based on a thermoplastic synthetic resin material called Resilon™. The real innovation of this system is its capacity of creating a core made of Resilon™ bonded to the cement which adheres to dentine walls previously conditioned with a self-etching primer(4) so no changes in the techniques of canal preparation are required. The aim of this study was to evaluate the capacity of two filling materials (gutta-percha and Resilon) to adapt to the canal anatomy, especially on the apical third, using the continuous wave of condensation technique. Our data suggest that in the third apical the gutta-percha best shows rheological properties that are as important as the bond capability.

  2. Root canal filling using Resilon: a review.

    LENUS (Irish Health Repository)

    Shanahan, D J

    2011-07-01

    Root canal treatment is achieved by chemo-mechanical debridement of the root canal system followed by filling. The filling material \\'entombs\\' residual bacteria and acts as a barrier which prevents the entrance of oral microorganisms and reinfection of the root canal system through microleakage. However, filling with contemporary root filling materials such as gutta-percha offers limited long-term resistance to microorganisms; as a result other materials such as Resilon have been investigated as alternatives. The aim of this review was to analyse the literature to consider whether Resilon is a suitable root canal filling material. A MEDLINE and Cochrane library search including various keyword searches identified several papers which investigated or discussed Resilon or RealSeal\\/Epiphany. Analysis of the literature demonstrated that the bulk of the literature is in vitro in nature, based largely on leakage-type studies, and demonstrates a wide variety of methodologies with conflicting findings; as a result meaningful conclusions are difficult. Within the limit of these in vitro studies Resilon appears to perform adequately in comparison to gutta-percha, however, as a result of the questionable merit of such studies, it cannot presently be considered an evidence-based alternative to the current gold standard gutta-percha. It is imperative that before Resilon is considered as a replacement material, a better understanding of the physical properties of the resin sealer and the reality of the adhesive \\'monoblock\\' are elucidated. The literature also demonstrates a paucity of quality long-term clinical outcome studies which will need to be addressed before firm conclusions can be reached.

  3. Comparing low volume saphenous-obturator block with placebo and femoral-obturator block for anterior cruciate ligament reconstruction: a randomized controlled trial

    DEFF Research Database (Denmark)

    Lenz, Katja; Jensen, Kenneth; Tanggaard, Katrine

    2018-01-01

    BACKGROUND: Anterior cruciate ligament reconstruction (ACL-RC) is often associated with moderate to severe postoperative pain even with a multimodal analgesic regimen. We aimed to compare the analgesic efficacy of low volume saphenous-obturator block with placebo and femoral- obturator block in p...

  4. Rehabilitation of large maxillary defect with two-piece maxillary obturators

    Directory of Open Access Journals (Sweden)

    Kanchan P Dholam

    2015-01-01

    Full Text Available The insertion and removal of an obturator in large maxillary defects with or without trismus is difficult. Fabrication of a two-piece obturator in such cases overcomes this problem. This article describes rehabilitation of large maxillary defects with two piece maxillary obturator of three types. All these obturators have a maxillary plate and a bulb component, which are approximated together by various techniques namely, silicone cover, embedded magnets, and press studs. Prosthetic rehabilitation of large maxillary defects with two-piece obturators offers the possibility of adequate oral rehabilitation by fabricating light weight prosthesis, which is easy to use. The bulb covers the undercut areas of the defect enhancing the facial contour and retention. It facilitates easy examination of underlying tissues, recreation of the anatomic barrier between the oral and nasal cavities and restoration of the function and esthetics. Thus, it adds to the quality of life.

  5. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  6. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: An ex vivo evaluation

    Directory of Open Access Journals (Sweden)

    Sreegowri

    2013-01-01

    Full Text Available Aim: The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA mixed with distilled water and 0.12% chlorhexidine (CHX gluconate when used as a root-end filling material using the dye-penetration technique. Materials and Methods: A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Results : No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. Conclusion : CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  7. Management of Oehler’s Type III Dens Invaginatus Using Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Jaya Ranganathan

    2016-01-01

    Full Text Available Dens Invaginatus is a dental malformation that poses diagnostic difficulties in the clinical context. This anomaly may increase the risk of pulp disease and can potentially complicate endodontic procedure due to the aberrant root canal anatomy. Compared to conventional radiographs, three-dimensional images obtained with Cone Beam Computed Tomography (CBCT are invaluable in the diagnosis of the extent of this anomaly and in the appropriate treatment planning. Oehler’s classification (1957 for Dens Invaginatus (DI into three types depending on the depth of the invagination has been used for treatment planning. Of the three types Type III DI is characterized by infolding of the enamel into the tooth up to the root apex and is considered as the most severe variant of DI and hence the most challenging to treat endodontically, due to the morphological complexities. This report describes a case of Oehler’s Type III DI in a necrotic permanent maxillary lateral incisor in which CBCT images played a key role in diagnosis and treatment planning. The case was managed successfully by a combination of nonsurgical and surgical endodontic therapy with orthograde and retrograde thermoplastic gutta percha obturation.

  8. A comparative evaluation of efficacy of protaper universal rotary retreatment system for gutta-percha removal with or without a solvent.

    Science.gov (United States)

    Kumar, M Sita Ram; Sajjan, Girija S; Satish, Kalyan; Varma, K Madhu

    2012-09-01

    The aim was to evaluate and compare the efficacy of ProTaper Universal rotary retreatment system with or without solvent and stainless steel hand files for endodontic filling removal from root canals and also to compare retreatment time for each system. Thirty extracted mandibular premolars with single straight canals were endodontically treated. Teeth were divided into three major groups, having 10 specimens each. Removal of obturating material in group 1 by stainless steel hand files with RC Solve, group 2 by ProTaper Universal retreatment instruments and group 3 by ProTaper Universal retreatment instruments along with RC solve was done. Retreatment was considered complete for all groups when no filling material was observed on the instruments. The retreatment time was recorded for each tooth. All specimens were grooved longitudinally in a buccolingual direction. The split halves were examined under a stereomicroscope and images were captured and analyzed. The remaining filling debris area ratios were considered for statistical analysis. With ANOVA test, statistical analysis showed that there was statistically no significant difference regarding the amount of filling remnants between the groups (P ProTaper Universal retreatment system files alone proved to be faster than the other experimental groups.

  9. Effects of Dissolving Solutions on the Accuracy of an Electronic Apex Locator-Integrated Endodontic Handpiece

    Directory of Open Access Journals (Sweden)

    Yakup Ustun

    2013-01-01

    Full Text Available The effects of three dissolving agents on the accuracy of an electronic apex locator- (EAL- integrated endodontic handpiece during retreatment procedures were evaluated. The true lengths (TLs of 56 extracted incisor teeth were determined visually. Twenty teeth were filled with gutta-percha and a resin-based sealer (group A, 20 with gutta-percha and a zinc oxide/eugenol-based sealer (group B, and 16 roots were used as the control group (group C. All roots were prepared to TL. Guttasolv, Resosolv, and Endosolv E were used as the dissolving solutions. Two evaluations of the handpiece were performed: the apical accuracy during the auto reverse function (ARL and the apex locator function (EL alone. The ARL function of the handpiece gave acceptable results. There were significant differences between the EL mode measurements and the TL (P<0.05. In these comparisons, Tri Auto ZX EL mode measurements were significantly shorter than those of the TL.

  10. Speech rehabilitation of maxillectomy patients with hollow bulb obturator.

    Science.gov (United States)

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-09-01

    To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  11. Speech rehabilitation of maxillectomy patients with hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Pravesh Kumar

    2012-01-01

    Full Text Available Aim: To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. Materials and Methods: A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery, after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. Results: The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Conclusion: Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  12. Oral function after maxillectomy and reconstruction with an obturator

    NARCIS (Netherlands)

    Kreeft, A.M.; Krap, M.; Wismeijer, D.; Speksnijder, C.M.; Smeele, L.E.; Bosch, S.D.; Muijen, M.S.A.; Balm, A.J.M.

    2012-01-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and

  13. A conservative method of retaining an interim obturator for a total maxillectomy patient

    Directory of Open Access Journals (Sweden)

    Nirmal Famila Bettie

    2017-01-01

    Full Text Available Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  14. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient.

    Science.gov (United States)

    Bettie, Nirmal Famila

    2017-11-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  15. Brief reports: ultrasound-guided obturator nerve block: a proximal interfascial technique.

    Science.gov (United States)

    Taha, Ahmad Muhammad

    2012-01-01

    In this report, I describe and evaluate a proximal ultrasound (US)-guided obturator nerve block technique using an interfascial local anesthetic (LA) injection deep to the pectineus muscle. The pectineus muscle was identified and followed, while the US probe was tilted cranially until the superior pubic ramus was visualized. In this plane, LA was injected interfascially between the pectineus and obturator externus. The median time required to identify the injection site was 4 seconds (95% confidence interval, 3-5 seconds). The median motor block onset was 4 minutes (95% confidence interval, 3-5 minutes). Both obturator nerve branches were blocked successfully in all patients (100%). The US-guided obturator nerve block using interfascial LA injection inferior to the superior pubic ramus, between the pectineus and obturator externus muscles, was shown to be a simple and successful technique.

  16. Healing process following application of set or fresh mineral trioxide aggregate as a root-end filling material.

    Science.gov (United States)

    Habibi, Mehdi; Ghoddusi, Jamileh; Habibi, Ataollah; Mohtasham, Nooshin

    2011-01-01

    An unsuccessful attempt to reach the apical area or to place the retrograde material is a major difficulty in periradicular surgery. The aim of this study was to compare the histological evaluation of the healing process following an orthograde versus a retrograde application of mineral trioxide aggregate (MTA) as a root-end filling material during apical surgery on cats' teeth in order to find out whether orthograde placement of MTA before surgery can be used instead of retrograde placement during surgery. In this experimental study, 24 canine teeth in 12 mature and healthy cats were filled with either MTA or gutta-percha in an orthograde manner. Two weeks later, the teeth with MTA were surgically exposed and resected to the set-MTA within the canals. The teeth previously filled by gutta-percha were also surgically exposed, and retrograde cavities were prepared at the root ends and filled with fresh-MTA. After 8 weeks, the animals were euthanized by vital perfusion. Six-micron histological slices were prepared from samples, stained by Hematoxylin & Eosin, and histologically studied by means of a light microscope. The collected data was analyzed by the Chi-square and the T-test. One of the samples in the fresh-MTA group was omitted during processing because of inappropriate sectioning. In the set-MTA group, 5 out of 12 showed chronic abscess, while in the fresh-MTA group, 2 out of 11 were discovered to have chronic abscess; however, no significant difference was observed (P>.05). Hard tissue healing (cementum, bone, cementum + bone formation) in the set-MTA and fresh-MTA groups were 7 out of 12 and 9 out of 11, respectively. While healing seemed more likely to occur in the fresh-MTA group, the difference was statistically insignificant (P>.05). The magnitude of bone, cementum, or bone and cementum formation showed slight differences between the two groups; however, the figures failed to show any marked differences (P>.05). Orthograde placement of MTA could be used

  17. Stress analysis in oral obturator prostheses: imaging photoelastic

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  18. The effect of immediate and delayed post-space preparation using extended working time root canal sealers on apical leakage

    Directory of Open Access Journals (Sweden)

    G. Chen

    2013-03-01

    Conclusion: Extended working time root canal sealers do not affect microleakage results using a warm gutta-percha vertical compaction technique. The sealing ability of extended working time root canal sealers on high heat conditions is as good as the standard working time root canal sealer during post-space preparation of different intervals.

  19. Obturator hernia: a rare case of acute mechanical intestinal obstruction.

    Science.gov (United States)

    Aydin, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  20. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    Science.gov (United States)

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  1. [Nonsurgical retreatment in a case of a radiolucent apical lesion].

    Science.gov (United States)

    Vicente Gómez, A; Rodríguez Ponce, A

    1989-01-01

    We present a case of failure that was helpful solved without surgical endodontic treatment. We don't achieve clinical success besides endodontic treatment was twice remade. Finally we decided to put a temporary filling with calcium hydroxide and wait until apical radiolucency disappear and complete our treatment with gutta-percha, sealer and lateral condensation.

  2. Obturator prostheses in post-oncological maxillofacial patients: our experience

    Directory of Open Access Journals (Sweden)

    Edoardo Brauner

    2014-12-01

    Full Text Available Background: Surgical procedures for tumors of the paranasal sinus, palatal epithelium, minor salivary glands or osteosarcoma of the upper jaw require a partial or total maxillectomy of the upper jaw. When the surgical procedure and/or radiation therapy result in a communication, the solution is necessarily prosthetical, through a palatal obturator that recreates a partition between the oral and nasal cavities. Methods: Authors selected 32 post-oncological patients with the upper maxilla completely edentulous prosthetically rehabilitated with a palatal obturator. Results: No serious complications or adverse reactions were reported during the fabrication of surgical or definitive obturators. All patients stated to benefit the palatal obturator in terms of quality of life. Conclusion: Prosthetic rehabilitation of edentulous maxillectomy with oral communication is a demanding challenge for the prosthodontist. The goals of prosthetic rehabilitation include separation of oral and nasal cavities to allow adequate deglutition and articulation of teeth, restore midfacial soft tissue contour and a satisfactory esthetic outcome. When, for any reason, the patient is not a suitable candidate for an implant-retained overdenture, a total removable prosthesis should ensure the most comfort in terms of swallowing, phonation and aesthetics.

  3. Obturator Hernia: A Rare Case of Acute Mechanical Intestinal Obstruction

    Directory of Open Access Journals (Sweden)

    Ibrahim Aydin

    2013-01-01

    Full Text Available Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  4. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report

    Science.gov (United States)

    Hou, Yue-Zhong; Huang, Zhi; Ye, Hong-Qiang; Zhou, Yong-Sheng

    2012-01-01

    The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory, pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator. PMID:22653550

  6. A comparative evaluation of efficacy of protaper universal rotary retreatment system for gutta-percha removal with or without a solvent

    Directory of Open Access Journals (Sweden)

    M Sita Ram Kumar

    2012-01-01

    Full Text Available Aim: The aim was to evaluate and compare the efficacy of ProTaper Universal rotary retreatment system with or without solvent and stainless steel hand files for endodontic filling removal from root canals and also to compare retreatment time for each system. Materials and Methods: Thirty extracted mandibular premolars with single straight canals were endodontically treated. Teeth were divided into three major groups, having 10 specimens each. Removal of obturating material in group 1 by stainless steel hand files with RC Solve, group 2 by ProTaper Universal retreatment instruments and group 3 by ProTaper Universal retreatment instruments along with RC solve was done. Retreatment was considered complete for all groups when no filling material was observed on the instruments. The retreatment time was recorded for each tooth. All specimens were grooved longitudinally in a buccolingual direction. The split halves were examined under a stereomicroscope and images were captured and analyzed. The remaining filling debris area ratios were considered for statistical analysis. Results: With ANOVA test, statistical analysis showed that there was statistically no significant difference regarding the amount of filling remnants between the groups (P < 0.05. Differences between the means of groups are statistically significant regarding the retreatment time. Conclusion: Irrespective of the technique used, all the specimens had some remnants on the root canal wall. ProTaper Universal retreatment system files alone proved to be faster than the other experimental groups.

  7. Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study.

    Science.gov (United States)

    Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha

    2017-07-01

    The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Comparison of the amount of apical debris extrusion associated with different retreatment systems and supplementary file application during retreatment process.

    Science.gov (United States)

    Çiçek, Ersan; Koçak, Mustafa Murat; Koçak, Sibel; Sağlam, Baran Can

    2016-01-01

    The type of instrument affects the amount of debris extruded. The aim of this study was to compare the effect of retreatment systems and supplementary file application on the amount of apical debris extrusion. Forty-eight extracted mandibular premolars with a single canal and similar length were selected. The root canals were prepared with the ProTaper Universal system with a torque-controlled engine. The root canals were dried and were obturated using Gutta-percha and sealer. The specimens were randomly divided into four equal groups according to the retreatment procedures (Group 1, Mtwo retreatment files; Group 2, Mtwo retreatment files + Mtwo rotary file #30 supplementary file; Group 3, ProTaper Universal retreatment (PTUR) files; and Group 4, PTUR files + ProTaper F3 supplementary file). The extruded debris during instrumentation were collected into preweighed Eppendorf tubes. The amount of apically extruded debris was calculated by subtracting the initial weight of the tube from the final weight. Three consecutive weights were obtained for each tube. No statistically significant difference was found in the amount of apically extruded debris between Groups 1 and 3 (P = 0.590). A significant difference was observed between Groups 1 and 2 (P file significantly increased the amount of apically extruded debris.

  9. Novel use of platelet-rich fibrin matrix and MTA as an apical barrier in the management of a failed revascularization case.

    Science.gov (United States)

    Yadav, Pankaj; Pruthi, Preeti Jain; Naval, Ruchika Roongta; Talwar, Sangeeta; Verma, Mahesh

    2015-08-01

    We report management of a failed revascularization/revitalization case, which could be due to inadequate removal of biofilm and bacteria in dentinal tubules. The use of an apical matrix barrier in form of a platelet-rich fibrin (PRF) membrane for stabilization of MTA in root end apexification procedure is described. The canal was cleansed of old MTA present in the cervical third using H files, irrigated using saline and finally irrigated with 2.5% NaOCl and saline. To obtain canal disinfection, calcium hydroxide paste was temporized in the canal. In subsequent appointments, PRF was placed at the root tip followed by 5-mm apical plug with mineral trioxide aggregate. One week later, the root canal was obturated with thermoplasticized gutta-percha. A 6-month and a 2-year follow ups showed reduction of periapical radiolucency and adequately functional tooth. One-visit apexification techniques provide an alternative treatment for failed revascularization cases. Follow up confirmed complete healing periradicularly. Apexification in one step using an apical barrier of PRF and a plug of MTA can be considered a predictable treatment and may be an alternative to long-term revascularization failures. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Clinical features and endodontic treatment of two-rooted mandibular canines: Report of four cases

    Directory of Open Access Journals (Sweden)

    Stojanac Igor

    2014-01-01

    Full Text Available Introduction. Predictable endodontic treatment depends on the dentist’s knowledge about root canal morphology and its possible anatomic variations. The majority of mandibular canines have one root and root canal, but 15% may have two canals and a smaller number may have two distinct roots. The following clinical reports describe endodontic treatment of mandibular canines with two roots and two root canals. Outline of Cases. Four clinical case reports are presented to exemplify anatomical variation in the human mandibular canine. Detailed analysis of the preoperative radiographs and careful examination of the pulp chamber floor detected the presence of two root canal orifices in all canines. Working length was determined with an electronic apex locator and biomechanical preparation was carried out by using engine driven BioRaCe Ni-Ti rotary instruments in a crown-down manner, followed by copious irrigation with 1% sodium hypochlorite. Definitive obturation was performed using cold lateral condensation with gutta-percha cones and Top Seal paste. The treatment outcome was evaluated using postoperative radiographs. Conclusion. Endodontists should be aware of anatomical variations of the treated teeth, and should never presume that canal systems are simple. [Projekat Ministarstva nauke Republike Srbije, br. 174005: Viscoelasticity of fractional type and optimization of shape in rod theory

  11. Histopathological study of healing in periapical lesions following endodontic treatments

    Directory of Open Access Journals (Sweden)

    A. Khayat

    1987-08-01

    Full Text Available This study was perfomed on twenty five teeth which showed radiographic lesions( 6mm over 25 mm. the teeth were arranged in seven different groups and root canal therapy ( by warm Gutta-percha technique as surgical intervention were performed at various time intervals. In this investigation, histologic studies of the periapical tissues begin shortly after elimination of the root canal system with or without root  canal obturation. This healing demonstrated with a replacement of granulation tissue by connective tissue, inflammatory cells diminish in number and densityb fibroblastic activity and their differentiation of osteoblastc osteoblastic activity forming osteoid and trabecular bone. The newly formed trabeculae extend from the periphery of the lesion to the center and root surfacesd nonorganized periodontal ligament fibers return to their original orientation soon after the newly formed trabeculae reach the apical root surface and form lamina duraInflammatory responses may continue simultaneously with periapical tissue regeneration and bone formation. Chronic inflammatory cells seem to be present occasionally in marrow spaces of the newly formed bone. Cellular activity and bone formation are demonstrated in the presence of the lining epithelium. This is seen between newly formed bone and apical root tip and might be suggestive of healing of the periapical cyst. 

  12. Comparing the reinforcing effects of a resin modified glassionomer cement, Flowable compomer, and Flowable composite in the restoration of calcium hydroxide-treated immature roots in vitro

    Directory of Open Access Journals (Sweden)

    S Prathibha Rani

    2011-01-01

    Full Text Available One hundred and sixty human permanent central incisors were enlarged to a 120 file size after crown removal procedure to simulate immature teeth. The root canals were filled with calcium hydroxide and stored for 15 days (phase I, 30 days (phase II, 90 days (phase III, and 180 days (Phase IV. At the end of these selected time periods, calcium hydroxide was cleaned off the root canals of forty teeth that were randomly selected and obturated with gutta-percha points in the apical 2 mm of the root canals with a sealer. The specimens were further equally divided into four groups. Unrestored Group I served as control and the root canals of teeth in the other three group specimens were reinforced with resin modified glassionomer cement (RMGIC (Group II, Flowable Compomer (Group III, and Flowable Composite (Group IV, respectively, using a translucent curing post. All specimens were subjected to compressive force using an Instron Testing machine, until fracture occurred. All the materials evaluated substantially reinforced the root specimens compared to the control. At the end of 180 days, Flowable composites showed maximum reinforcement compared to the other groups; however, no significant differences were found between the reinforcement capabilities of Flowable Compomer and RMGIC.

  13. Effect of the angle of apical resection on apical leakage, measured with a computerized fluid filtration device.

    Science.gov (United States)

    Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda

    2011-03-01

    We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an

  14. Obturator hernia should be considered in the differential diagnosis of hip and knee pain.

    Science.gov (United States)

    Belli, Ahmet Korkut; Memiş, Gündüz; Dere, Özcan; Koşan, Ulaş; Nazlı, Okay

    2016-11-01

    Obturator hernia is a rare disease usually occurring in debilitated elderly women. Pain radiating down the medial thigh and knee (Howship-Romberg sign) is a specific sign of the disease. Presently described is a case of obturator hernia in a 73-year-old female patient who presented with severe left hip pain radiating down the medial thigh and knee, nausea, and loss of appetite. Initially, vertebral disc herniation was thought to be cause, but abdomino-pelvic computed tomography scan revealed left strangulated obturator hernia. Diagnosis of obturator hernia can be challenging. Physicians should consider obturator hernia in the differential diagnosis of knee and hip pain, and investigate for Howship-Romberg sign. Early diagnosis of the disease not only decreases morbidity and mortality, but also presents opportunity to treat with minimally invasive methods.

  15. Enhanced retention of a maxillofacial prosthetic obturator using precision attachments: Two case reports

    OpenAIRE

    Murat, Sema; Gurbuz, Ayhan; Isayev, Abulfaz; Dokmez, Bahadir; Cetin, Unsun

    2012-01-01

    The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator’s aesthetic advantages. This clinical report describes the prosthetic rehabil...

  16. Variación intraespecifica en el uso de Percha Nocturna de Basiliscus galeritus (Sauria: Corytophanidae en Isla Palma, Pacífico Colombiano

    Directory of Open Access Journals (Sweden)

    Óscar Darío Hernández-Córdoba

    2012-01-01

    Full Text Available Las variaciones en el uso de percha nocturna son en parte un reflejo de la partición de recursos que permite la coexistencia al disminuir la competencia intraespecifica entre individuos de diferentes sexos y tamaños. En este trabajo se evaluó el uso de percha nocturna en los machos, las hembras y los juveniles de Basiliscus galeritus en Isla Palma - Pacífico Colombiano en abril de 2011. Los individuos fueron capturados manualmente y se tomó la información de la altura de la percha, posición en la que estaban perchados, longitud rostro cloacal y cobertura vegetal. Se registraron 39 individuos, encontrando que el tipo de percha utilizado con mayor frecuencia fueron las ramas (46,15% seguido por las hojas (38,46% y ocasionalmente fueron observados sobre lianas, suelo y tallos. Se evaluo el grado de asociación entre los sexos y cada una de las variables estudiadas con la altura de percha utilizando tablas de contingencia. No se detectó asociación alguna aunque el uso de percha estuvo relacionado con el tamaño corporal del individuo, independiente de su sexo. (rs = ‑0,08, p = 0,7.

  17. Fabrication of Closed Hollow Bulb Obturator Using Thermoplastic Resin Material

    Directory of Open Access Journals (Sweden)

    Bidhan Shrestha

    2015-01-01

    Full Text Available Purpose. Closed hollow bulb obturators are used for the rehabilitation of postmaxillectomy patients. However, the time consuming process, complexity of fabrication, water leakage, and discoloration are notable disadvantages of this technique. This paper describes a clinical report of fabricating closed hollow bulb obturator using a single flask and one time processing method for an acquired maxillary defect. Hard thermoplastic resin sheet has been used for the fabrication of hollow bulb part of the obturator. Method. After fabrication of master cast conventionally, bulb and lid part of the defect were formed separately and joined by autopolymerizing acrylic resin to form one sized smaller hollow body. During packing procedure, the defect area was loaded with heat polymerizing acrylic resin and then previously fabricated smaller hollow body was adapted over it. The whole area was then loaded with heat cure acrylic. Further processes were carried out conventionally. Conclusion. This technique uses single flask which reduces laboratory time and makes the procedure simple. The thickness of hollow bulb can be controlled and light weight closed hollow bulb prosthesis can be fabricated. It also minimizes the disadvantages of closed hollow bulb obturator such as water leakage, bacterial infection, and discoloration.

  18. Prevalence of Enterococcus faecalis and Porphyromonas gingivalis in infected root canals and their susceptibility to endodontic treatment procedures: A molecular study

    OpenAIRE

    Stojanović Nikola; Krunić Jelena; Popović Branka; Stojičić Sonja; Živković Slavoljub

    2014-01-01

    Introduction. Because apical periodontitis is recognizably an infectious disease, elimination or reduction of intracanal bacteria is of utmost importance for optimum treatment outcome. Objective. The prevalence of Enterococcus faecalis and Porphyromonas gingivalis in infected root canals was studied Also, the effect of endodontic therapy by using intracanal medicaments, calcium hydroxide paste (CH) or gutta-percha points containing calcium hydroxide (CH-GP)...

  19. Oral function after maxillectomy and reconstruction with an obturator.

    Science.gov (United States)

    Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M

    2012-11-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Full Mouth Reconstruction of a Skeletal Class II Division 1 Patient with Adenoid Cystic Carcinoma Using an Interim Immediate Obturator and a Definitive Obturator

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available A 61-year-old female patient with adenoid cystic carcinoma (ACC of the right maxilla and Angle class II division 1 malocclusion had received a subtotal maxillectomy in right side and used a conventional clasp-retained obturator. After implants placement, a maxillary interim immediate obturator (IIO and then a definitive obturator using six endosseous implants were fabricated. During one-year follow-up, the patient was completely satisfied. Ideally, after implants placement in edentulous patients suffering from hemimaxillectomy, an implant-supported obturator (ISO is designed in order to prevent nasal reflux and to improve speech and swallowing. However, in the following case, because of skeletal class II division 1 malocclusion and implants insertion in the premaxilla, using an ISO was impossible because it would cause excessive upper lip protrusion and lack of anterior teeth contact. Therefore, a five-unit implant-supported fixed partial denture (FPD was fabricated in the maxillary anterior segment so that anterior teeth contacts were possible and the patient’s normal lip support was achieved. A bar and three ball attachments were used in the maxillary posterior segment. A closed-hollow-bulb ISO was preferred. Conventional ISO in these patients results in several problems. Using a maxillary anterior FPD along with ISO caused satisfactory results in the current patient.

  1. Obturator yang Berfungsi Sebagai Protesa pada Perawatan Pasien Sumbing Langitan (Laporan Kasus

    Directory of Open Access Journals (Sweden)

    Avy Permata Sari

    2015-11-01

    Full Text Available Palatal cleft is opening of palatal including palatum mole and durum. It is caused by growth and development disturbance intra uterine. There are some etiology lke genetic factor, infection, drugs, mutagenic material, malnutrition, and psychological problem during pregnancy. In this case the patient came to our clinic to be made obturator to close the palatal fistule that caused speech and nutrition problems. Because there were some missing teeth, the obturator was combined with prosthetic design. At recall visit the obturator improved speech, swallow, and mastication functions and aesthetics and patient showed the ability to use it by himself.

  2. [MORPHOLOGICAL CHANGES OF THE LIVER IN OBTURATION JAUNDICE, CAUSED BY CHOLEDOCHOLITHIASIS, DEPENDING ON ITS DURATION].

    Science.gov (United States)

    Sipliviy, V A; Yevtushenko, D V; Naumova, O V; Andreyeshchev, S A; Yevtushenko, A V

    2016-02-01

    Abstract The results of surgical treatment of 184 patients for obturation jaundice, caused by choledocholithiasis, were analyzed. Morphological changes of the liver were studied in 20 patients. There were three groups of patients delineated, depending on the obturation jaundice duration: up to 7 days, from 8 to 14 days, more than 15 days, and also a group of patients after the bile outflow restoration. The obturation jaundice occurrence in choledocholithiasis is accompanied by significant morphological changes in the liver, severity of which is enhancing while the obturation jaundice persistence increasing. While persistence of obturation jaundice through 8 days and more the connective tissue volume is enhancing, a relative volume of hepatocytes is reducing and a stromal-parenchymatous index is increasing. The bile outflow restoration secures significant reduction of intensity of alterative and inflammatory changes in hepatic parenchyma, as well as activation of reparative processes in the tissue. In cholangitis, caused by P. aeruginosa and E. coli, according to morphological investigations data, in the liver a diffuse purulent cholangitis on background of chronic changes in accordance to duration of the obturation jaundice persists.

  3. Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material

    Science.gov (United States)

    Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can

    2016-01-01

    Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429

  4. Characterisation of Roseomonas mucosa isolated from the root canal of an infected tooth.

    Science.gov (United States)

    Diesendorf, Nina; Köhler, Stefanie; Geißdörfer, Walter; Grobecker-Karl, Tanja; Karl, Matthias; Burkovski, Andreas

    2017-06-14

    The genus Roseomonas comprises a group of pink-pigmented, slow-growing, aerobic, non-fermentative Gram-negative bacteria, which have been isolated from environmental sources such as water and soil, but are also associated with human infections. In the study presented here, Roseomonas mucosa was identified for the first time as part of the endodontic microbiota of an infected root canal and characterised in respect to growth, antibiotic susceptibility and biofilm formation. The isolated R. mucosa strain showed strong slime formation and was resistant to most β-lactam antibiotics, while it was susceptible to aminoglycosides, carbapenemes, fluorochinolones, polymyxines, sulfonamides and tetracyclines. Biofilm formation on artificial surfaces (glass, polystyrene, gutta-percha) and on teeth was tested using colorimetric and fluorescence microscopic assays. While solid biofilms were formed on glass surfaces, on the hydrophobic surface of gutta-percha points, no confluent but localised, spotty biofilms were observed. Furthermore, R. mucosa was able form biofilms on dentin. The data obtained indicate that R. mucosa can support establishment of endodontic biofilms and furthermore, infected root canals might serve as an entrance pathway for blood stream infections by this emerging pathogen.

  5. Effectiveness of ProTaper, D-RaCe, and Mtwo retreatment files with and without supplementary instruments in the removal of root canal filling material.

    Science.gov (United States)

    Marques da Silva, B; Baratto-Filho, F; Leonardi, D P; Henrique Borges, A; Volpato, L; Branco Barletta, F

    2012-10-01

    To assess the efficacy of different retreatment rotary files in removing gutta-percha and endodontic sealer from canals. Ninety straight single-rooted premolars were prepared up to a size 30 and filled with gutta-percha and sealer and then randomly assigned to six retreatment groups (n = 15). Groups I, III, and V were retreated using rotary systems ProTaper Universal Retreatment (PTUR), D-RaCe, and Mtwo Retreatment, respectively. Groups II, IV, and VI were retreated using the additional instruments F4, size 40, .04 taper RaCe, and size 40, .04 taper Mtwo, respectively. The roots were split vertically, and images of the halves were obtained using a high-resolution scanner and evaluated with AutoCAD software to calculate the percentage of residual material. Data were analyzed with Kruskal-Wallis and Student-Newman-Keuls tests using a 5% significance cutoff (P 0.05) between groups when additional instruments were used. The percentage of residual material was lowest in the PTUR group and was statistically significant only when compared to the D-RaCe system (P = 0.0038). All root canals had residual filling material after retreatment even when additional instruments were used. © 2012 International Endodontic Journal.

  6. A cast partial obturator with hollow occlusal shim and semi-precision attachment

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2018-01-01

    Full Text Available A maxillofacial patient's quality of life is distorted and social integration becomes difficult. An obturator is a maxillofacial prosthesis used to close a congenital or acquired tissue defect, primarily of the hard palate and/or contiguous alveolar/soft-tissue structures. Subsequently, it restores the esthetics, speech, and function. The present clinical report aimed for the prosthetic rehabilitation of a maxillectomy defect by the incorporation of a semi-precision attachment as PRECI-SAGIX – male part of 2.2 mm on fixed partial denture (#22 and #23 teeth and matrix – plastic female part of size 2.2 mm and height 4.2 mm of yellow on cast partial in polymer base. It aids in the retention of a hollow lightweight obturator. The technique also described the method to make a bulbless obturator with a hollow self-cured acrylic resin occlusal shim. A patient is quite satisfied with bulb less, lightweight cast partial and hollow shim palatal obturator.

  7. Candida albicans in patients with oronasal communication and obturator prostheses

    OpenAIRE

    MATTOS, Beatriz Silva Câmara; SOUSA, Andréa Alves de; MAGALHÃES, Marina Helena C. G. de; ANDRÉ, Marcia; BRITO E DIAS, Reinaldo

    2009-01-01

    Patients using obturator prostheses often present denture-induced stomatitis. In order to detect the presence of oral Candida albicans in patients with oronasal communications and to evaluate the effectiveness of a topical antifungal treatment, cytological smears obtained from the buccal and palatal mucosa of 10 adult patients, and from the nasal acrylic surface of their obturator prostheses were examined. A therapeutic protocol comprising the use of oral nystatin (Mycostatin®) and prosthesis...

  8. Obturator Neuromodulation with Laparoscopic Placement of an Obturator Lead for the Treatment of Intractable Opioid Dependent Chronic Pelvic Pain due to Obturator Neuralgia.

    Science.gov (United States)

    Marvel, Richard P

    2018-05-12

    Chronic pelvic pain(CPP) is a common condition in women that can have a devastating effect on quality of life. Some of the most severe forms of CPP are related to peripheral nerve injuries causing persistent neuropathic pain. This is a case of a young woman with severe opioid dependent chronic pelvic and right groin pain due to obturator neuralgia. She had failed a multitude of treatments including multiple medications, manual physical therapy, nerve blocks, surgical neurolysis and spinal cord stimulation without significant benefit. She underwent a trial of peripheral neuromodulation of the obturator nerve with laparoscopic placement of a quadripolar lead. During the 6-day trial she had almost complete relief of her pain; therefore, she underwent permanent implantation of an intermittent pulse generator. Over the next 6 months she was completely weaned completely off her chronic opioids. At 23 months post implantation, she had essentially no pain and is no longer on any analgesic, antidepressant or membrane stabilizing medications. Peripheral Neuromodulation has the potential to alleviate pain and significantly improve quality of life in women with longstanding neuropathic chronic pelvic pain who have failed multimodal conservative therapy. Copyright © 2018. Published by Elsevier Inc.

  9. The influence of obturators on the respiration of patients with maxillary defects: a clinical study.

    Directory of Open Access Journals (Sweden)

    Xian Dong

    Full Text Available The study evaluated the effects of obturators on respiratory function by analyzing the changes in nasal anatomic structures and physiologic function in maxillectomy patients with and without obturators. Twenty-six patients who underwent maxillectomy were chosen and rehabilitated with obturators by a single maxillofacial prosthodontist. The geometric shape of the nasal cavity, the nasal airway resistance, and the ratio of residual volume to total lung capacity (RV/TLC were evaluated using acoustic rhinometry, rhinomanometry, and a pulmonary function test apparatus, respectively. All patients were tested twice, with and without their obturators. The results were statistically analyzed with a paired t-test. The nasal cavities (0-7 cm to the anterior nostril of the patients with obturators had a significantly smaller volume ([-8.92, -0.60], P = 0.027, smaller effective nasal cross-sectional area MCA2 ([-3.80, -1,81], P < 0.0001, increased airflow in the nasal cavity ([17.76, 147.39], P = 0.015, reduced nasal airway resistance ([-0.11, -0.02], P = 0.009, and reduced RV/TLC ([-5.32, -1.30], P = 0.004 compared with the patients without obturators. According to the results of this study, obturators can improve respiratory function by effectively decreasing the volume of enlarged nasal cavities as well as the nasal air resistance and volume of anatomical dead space after maxillectomy.

  10. Examination of Articulation in Patient Using Obturator by Means of Computer Planning

    Directory of Open Access Journals (Sweden)

    Somaieh Allahiary

    2013-02-01

    Full Text Available Background and Aims: Approximately 5% of cancers involve structures of oral cavity. Partial resection of maxilla (maxillectomy may be performed in these cases. Maxillectomy often results in significant functional disabilities such as inability in mastication, deglutition and speech with adverse impact on psychological statusand social life of patients. Obturator prosthesis is a prosthodontic treatment to separate nasal and oral cavities and restore the critical above mentioned functions. The assessment of speech is considered to examine speech function restored by the treatment. The purpose of this study was to evaluate the speech in patients with resected maxilla who have been treated by obturator prosthesis from a pool of related patients in the Prosthodotnics department ofdental faculty, Tehran University of Medical Sciences. The evaluation was performed with computer software using sentence intelligibility (SI test. Materials and Methods: This cross sectional study was conducted on 10 subjects (23-66 years referred to the Prosthodontics department of the faculty and received an obturator. After primary examination of the prosthesis,the patients completed SI test in an acoustic room under guidance of a speech therapist. The performed tests were analyzed by the speech therapist. In addition, the SI with and without the prosthesis was evaluate by lay audience. The statistical analyses were performed using Wilcoxon-signed rank test and Weighted Kappa. Results: Significant differences were found between SI tests with and without the obturators (P<0.001. Two of 10 patients showed problems in speech function using obturator. Conclusion: Within the limitations of the present study, obturators had significant effect on improvement of the speech outcomes of examined patients. Improvement of the quality of life could be predicted.

  11. Quality of Life in Patients After Maxillectomy and Placement of Prosthetic Obturator.

    Science.gov (United States)

    Chen, Cheng; Ren, Wen-Hao; Huang, Rui-Zhe; Gao, Ling; Hu, Zhi-Ping; Zhang, Lin-Mei; Li, Shao-Ming; Dong, Kai; Qi, Hong; Zhi, Ke-Qian

    2016-01-01

    The aim of this study was to assess quality of life (QoL) and obturator functioning in patients having undergone a maxillectomy as a tumor ablative resection and rehabilitation with a prosthetic obturator. The University of Washington Quality of Life scale version 4 (UW-QoLv4) and the Obturator Functioning Scale (OFS) were used to evaluate the self-reported QoL and obturator functioning. The effects of demographic and treatment variables on QoL were assessed using age, defect size, postoperative radiotherapy (RT), neck dissection, and dentition. The study included 16 men and 13 women with a mean age of 48.8 years. Of the 29 patients, 16 had a Brown Class 2a or smaller defect and 13 had a Brown Class 2b or larger defect. The mean OFS score (P = .004) and the physical (P = .001) and social-emotional function scores (P = .001) of the patients who received postoperative RT were significantly lower than those who did not receive postoperative RT. The subscales for swallowing (P = .008), saliva (P = .001), pain (P = .001), and shoulder function (P = .002) correlated strongly with postoperative RT on the UW-QoL. The subscales for pronunciation (P = .007) and saliva (P = .002) correlated significantly with RT on the OFS. The mean OFS scores were significantly lower for the patients with a Brown Class 2a or smaller defect than for Brown Class 2b or larger (P = .005). Postoperative RT was the strongest variable affecting QoL in patients with maxillectomy and prosthetic obturator reconstruction. The size of the defect slightly influenced the obturator function; however, it did not influence the overall QoL.

  12. Successful Treatment of Gluteal Pain from Obturator Internus Tendinitis and Bursitis with Ultrasound-Guided Injection.

    Science.gov (United States)

    Chen, Boqing; Rispoli, Leia; Stitik, Todd; Leong, Michelle

    2017-10-01

    This case report describes what the authors believe is the first case of a patient with obturator internus tendinitis and bursitis successfully treated with a corticosteroid injection using a trans-tendinous lateral to medial approach. The patient presented with right gluteal pain not relieved by physical therapy or right hip and ischial bursa corticosteroid injections. Pelvic and lumbar spine MRIs and EMG/NCS findings were unremarkable. Physical examination demonstrated tenderness to palpation at the right middle lower gluteal region. Ultrasound imaging with sonopalpation identified the maximal local tender point as the right obturator internus muscle and/or its underlying bursa. A 22-gauge 3.5-inch needle was inserted in-plane to the transducer and longitudinal to the obturator internus from a lateral to medial direction, an approach previously described in cadavers. The obturator internus tendon sheath and bursa were injected with 2.5 ml of 0.5% lidocaine combined with 10 mg of triamcinolone. The patient reported immediate complete relief of pain with continued relief at 2 and 6 months post-injection. This case report demonstrates an injection of the obturator internus tendon sheath and bursa using a trans-tendinous approach, which may be successful for treatment of patients presenting with persistent gluteal pain from obturator internus tendinitis and bursitis.

  13. Obturator or "lateral" bypass in the management of infected vascular prostheses at the groin

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2002-01-01

    Full Text Available The infection of the previously implanted vascular graft at the groin, is associated with great mortality and morbidity rate [1]. The authors present a retrospective study in which they analyzed management of infected vascular prostheses at the groin, using obturator bypass in 26 cases, and "lateral" bypass in 15 cases. The indications for obturator bypass reconstructions included: 20 infections of aorto-femoral grafts, two infected pse udoaneurysms in the groin after RTA of the superficial femoral artery, and 4 infections of iliac-femoral grafts. The indications for lateral bypass reconstructions were: infections after aorto-femoral reconstructions - 8 cases; infection after femora-popliteal reconstructions - 4 cases; infection after iliac-femoral reconstruction - 2 patients, and one infected pseudoaneurysm in the groin after RTA of the superficial femoral artery. In 3 subjects obturator bypass was performed using extraperitoneal approach while in other 23 patients transperitoneal approach was done by donor's artery. The obturator bypass was performed using a PTFE graft in 3 cases and Dacron graft in 23. The donor's artery used for obturator bypass was a noninfected proximal part of aortofemoral graft in 20 cases, and iliac artery in 6 patients. The superfical femoral artery was recipient artery for obturator bypass in 3 cases, deep femoral artery in one case, and above the knee popliteal artery in 22 cases (Figure 1. In two patients transperitoenal approach to donors artery for "lateral" bypass has been used, and in 13 cases extraperitoneal. The proximal noninfected part of aorto femoral graft was used as a donor's artery for lateral bypass in 8 patients, while common iliac artery in 7 subjects. In 5 cases recon structions were performed using PTFE grafts, in 3 using autologous saphenous vein grafts, and in 7 using Dacron grafts. The recipient artery for "lateral" bypass was deep femoral in 8 cases, superficial femoral in three patients and

  14. Diagnosis and root canal treatment in a mandibular premolar with three canals.

    Science.gov (United States)

    Soares, Lanuce Rosa; Arruda, Marcos; de Arruda, Marcos Pôrto; Rangel, Andréa Leão; Takano, Edson; de Carvalho Júnior, Jacy Ribeiro; Saquy, Paulo Cesar

    2009-01-01

    This paper presents a case report of a left mandibular second premolar with three canals and three different apical foramina. A 39-year-old male patient presented to our clinic with pain in the mandibular left second premolar. Initially, pain was caused by cold stimulus and later was spontaneously. The intraoral clinical examination revealed a fractured amalgam restoration with occlusal caries. Percussion and cold (Endo-Frost) tests were positive. The radiographic examination showed the presence of two roots. The probable diagnosis was an acute pulpitis. After access cavity, it was observed remaining roof of the pulp chamber and mild bleeding in the tooth lingual area, indicating the possible presence of a third canal. The endodontic treatment was completed in a single session using Root ZX apex locator and K3 NiTi rotary system with surgical diameter corresponding to a .02/45 file in the three canals and irrigation with 1% sodium hypochlorite. The canals were obtured with gutta-percha cones and Sealer 26 using the lateral condensation technique. After 1 year of follow-up, the tooth was asymptomatic and periapical repair was observed radiographically. Internal alterations should be considered during the endodontic treatment of mandibular second premolars. The correct diagnosis of these alterations by the analysis of preoperative radiographs can help the location of two or more canals, thereby avoiding root therapy failure.

  15. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  16. Comparison of the sealing ability of mineral trioxide aggregate and Portland cement used as root-end filling materials.

    Science.gov (United States)

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Eskandarinezhad, Mahsa; Shakouei, Sahar; Unchi, Mahsa

    2011-12-01

    Inadequate apical seal is the major cause of surgical endodontic failure. The root-end filling material used should prevent egress of potential contaminants into periapical tissue. The purpose of this study was to compare the sealing ability of four root-end filling materials: white mineral trioxide aggregate (MTA), gray MTA, white Portland cement (PC) and gray PC by dye leakage test. Ninety-six human single-rooted teeth were instrumented, and obturated with gutta-percha. After resecting the apex, an apical cavity was prepared. The teeth were randomly divided into four experimental groups (A: white MTA, B: gray MTA, C: white PC and D: gray PC; n = 20) and two control groups (positive and negative control groups; n = 8). Root-end cavities in the experimental groups were filled with the experimental materials. The teeth were exposed to Indian ink for 72 hours. The extent of dye penetration was measured with a stereomicroscope at 16× magnification. The negative controls showed no dye penetration and dye penetration was seen in the entire root-end cavity of positive controls. However, there was no statistically significant difference among the four experimental groups (P > 0.05). All retrograde filling materials tested in this study showed the same microleakage in vitro. Given the low cost and apparently similar sealing ability of PC, PC could be considered as a substitute for MTA as a root-end filling material.

  17. Closed hollow bulb obturator--one-step fabrication: a clinical report.

    Science.gov (United States)

    Buzayan, Muaiyed M; Ariffin, Yusnidar T; Yunus, Norsiah

    2013-10-01

    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing. © 2013 by the American College of Prosthodontists.

  18. [A comparative study on treating femal stress urinary incontinence with TVT-Abbrevo and TVT-Obturator].

    Science.gov (United States)

    Li, W L; Lu, Z W; Li, F P; Yu, H Y

    2016-07-26

    To compare the effectiveness and complications of TVT-Abbrevo (tension-free vaginal tape-Abbrevo) and TVT-Obturator (tension-free vaginal tape-obturator) for the treatment of female stress urinary incontinence (SUI). From Nov.2012 to Nov.2013, 117 patients suffering from SUI were treated with TVT-Abbrebo (n=79) or TVT-Obturator (n=38) procedure, the clinical efficacy and operation-correlated complications were observed. A total of 117 cases, 107 cases of urinary incontinence symptoms disappeared completely, 10 cases were improved. 72 cases (91.1%) were cured and 7 cases (8.9%) were improved in TVT-Abbrevo group; 35 cases (92.1%) were cured and 3 cases (7.9%) were improved in TVT-Obturator group. No significant differences could be found for the curing rates between two groups (P>0.05). Compared with the TVT-Obturator group, the TVT-Abbrevo group had less patients complaining of inner thigh pain at 24 h and 1 w after surgery (PTVT-Abbrevo and TVT-Obturator group (P>0.05). No intraoperative complications such as blood vessel, nerve, bladder damage were recorded and no postoperative retropubic hematoma, tape adjustment and other complications occurred in two goups. No recurrence after 1 year follow-up. The study shows that TVT-Abbrevo procedure is safe and efficacy in treatment of SUI, and associated with low incidence of recent postoperative inner thigh pain.

  19. Comparison of different retreatment techniques and root canal sealers: a scanning electron microscopic study

    Directory of Open Access Journals (Sweden)

    Neslihan Simsek

    2014-05-01

    Full Text Available The aim of this study was to evaluate the effectiveness of two retreatment techniques, in terms of the operating time and scanning electron microscopy (SEM results, in removing three different root canal sealers from root canals that were previously filled with gutta-percha. Sixty extracted single-rooted human premolars were divided into three groups and filled with iRoot SP, MM Seal, and AH Plus sealers, along with gutta-percha, through a lateral compaction technique. Root canal fillings of the samples were removed by ESI ultrasonic tips or R-Endo files. The time to reach the working length was recorded. Longitudinally sectioned samples were examined under SEM magnification. Each picture was evaluated in terms of the residual debris. Data were statistically analyzed with the Kruskall-Wallis test. No statistically significant differences were found in terms of operating time (p>0.05. Significant differences in the number of debris-free dentinal tubules were found among the root canal thirds, but this finding was not influenced by the experimental group (p < 0.05. Resin sealer tags were observed inside the dentinal tubules in the MM Seal group. Under the conditions of this study, it may be established that there was no difference among the sealers and retreatment techniques.

  20. Effectiveness of rotatory and reciprocating movements in root canal filling material removal

    Directory of Open Access Journals (Sweden)

    Emmanuel João Nogueira Leal SILVA

    2015-01-01

    Full Text Available The purpose of this study was to compare the efficacy of reciprocating and rotary techniques for removing gutta-percha and sealer from root canals. Forty straight and oval single-rooted premolars were prepared up to size 30, filled with gutta-percha and sealer, and then randomly allocated to two experimental retreatment groups: ProTaper Retreatment System (PTRS and WaveOne System (WS. Procedural errors, time of retreatment and apically extruded material were recorded for all the roots. The roots were radiographed after retreatment. The percentage of residual material was calculated using image analysis software. The data were analyzed by Kolmogorov-Smirnov and t tests, with a significance level set at 5%. No system completely removed the root filling material from the root canal. No significant differences were observed between the systems, in terms of residual filling material in any tested third (p > 0.05. WS was faster in removing filling material than PTRS (p< 0.05. Extrusion was observed in 4 cases in PTRS and in 5 cases in WS. No procedural errors were observed in either group. It can be concluded that although no differences were observed in the efficacy of PTRS and WS for removing root filling material, WS was faster than PTRS.

  1. [Clinical-diagnostic estimation of carbohydrates metabolism in obturation jaundice].

    Science.gov (United States)

    Nychytaĭlo, M Iu; Malyk, S V

    2004-07-01

    Complex examination of 175 patients with obturation jaundice was conducted, peculiar attention was spared to the carbohydrates metabolism changes, characterizing hepatic state. It was established, that in obturation jaundice in the liver there are occurring inflammatory changes and disturbances of all kinds of metabolism, including that of carbohydrates, severity of which depends on duration of jaundice, the concurrent diseases presence, they shows lowering of the glucose and glycogen level in the blood, as well as the hepatic glycogen content, that's why they may be applied as a complex of prognostic criterions for the disease course. An early conduction of operative treatment, elimination of the biliary ducts impassability promote the rehabilitation period shortening and the hepatic functional activity normalization.

  2. Obturator nerve schwannoma presenting as an adnexal mass: case report

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, M.; Thurston, W.A.; Merchant, N. [The Toronto Hospital, Dept. of Medical Imaging, Toronto, Ontario (Canada); Murphy, K.J. [The Toronto Hospital, Dept. of Obstetrics and Gynecology, Toronto, Ontario (Canada)

    1999-02-01

    Schwannomas are relatively common, benign nerve-sheath tumours. They arise most commonly from either cranial nerves or the dorsal root of spinal nerves. Schwannomas have also been reported to occur in peripheral nerve-root trunks, although this location is much less common. We report a case of a 45-year-old woman with a large pelvic mass originally believed to be an ovarian tumour. Following surgical excision, the tumour was found to be a schwannoma of the obturator nerve. To our knowledge, there are no reported cases of an obturator nerve schwannoma. The imaging features of schwannomas are reviewed. (author)

  3. EDITORIAL: Measurement techniques for multiphase flows Measurement techniques for multiphase flows

    Science.gov (United States)

    Okamoto, Koji; Murai, Yuichi

    2009-11-01

    Research on multiphase flows is very important for industrial applications, including power stations, vehicles, engines, food processing and so on. Multiphase flows originally have nonlinear features because of multiphase systems. The interaction between the phases plays a very interesting role in the flows. The nonlinear interaction causes the multiphase flows to be very complicated. Therefore techniques for measuring multiphase flows are very useful in helping to understand the nonlinear phenomena. The state-of-the-art measurement techniques were presented and discussed at the sixth International Symposium on Measurement Techniques for Multiphase Flows (ISMTMF2008) held in Okinawa, Japan, on 15-17 December 2008. This special feature of Measurement Science and Technology includes selected papers from ISMTMF2008. Okinawa has a long history as the Ryukyus Kingdom. China, Japan and many western Pacific countries have had cultural and economic exchanges through Okinawa for over 1000 years. Much technical and scientific information was exchanged at the symposium in Okinawa. The proceedings of ISMTMF2008 apart from these special featured papers were published in Journal of Physics: Conference Series vol. 147 (2009). We would like to express special thanks to all the contributors to the symposium and this special feature. This special feature will be a milestone in measurement techniques for multiphase flows.

  4. Obturator Hernia: diagnosis and management under conditions of ...

    African Journals Online (AJOL)

    85.7%) underwent full resection and anastomosis, and one (14.3%) had partial resection. Hernia defect was closed in four (57.1%). Wound infection was common (71.4%) and three (43%) died. Conclusion: Obturator hernia is mainly a disease ...

  5. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    Science.gov (United States)

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  6. Comparative evaluation of three obturation techniques in primary incisors using digital intra-oral receptor and C.B.C.T-an in vitro study.

    Science.gov (United States)

    Akhil, Jose E J; Prashant, Babaji; Shashibushan, K K

    2018-05-10

    Successful pulpectomy in primary teeth depends on quality of obturation. It can be evaluated using digital intra-oral receptor (D.I.O.R) and cone beam computed tomography (C.B.C.T). The purposes of this study were to compare 3 different obturation techniques such as lentulospiral, insulin syringe, and endodontic plugger in primary incisors and to evaluate its quality of obturation using D.I.O.R and C.B.C.T technique. Thirty-three extracted primary incisors were biomechanically prepared and obturated with zinc oxide eugenol cement by 3 different obturation techniques. The obturation was evaluated for length of obturation and voids using D.I.O.R and C.B.C.T methods. There was a statistically significant difference between all the groups in length of obturation (P = 0.02) in both D.I.O.R and C.B.C.T. Significant differences (P = 0.03) were present in number of voids among 3 obturation techniques in C.B.C.T. Statistically more voids were observed with D.I.O.R in lentulospiral (P = 0.04) group and in insulin syringe (P = 0.02) group. Acceptable result was obtained with lentulospiral in length of obturation compared to insulin syringe and endodontic plugger technique. Insulin syringe technique resulted in increased underfilling with least number of voids. More number of voids were seen in middle one-third and least number of voids were observed at apical one third of the root among all the 3 techniques of obturation. The study concluded that void identification is improved with D.I.O.R compared to C.B.C.T. Lentulospiral reported effective length of obturation, while insulin syringe with least number of voids. D.I.O.R (2-Dimensional) is efficient in detecting voids compared to C.B.C.T (3-Dimensional) in obturated primary teeth.

  7. Aesthethic and masticatory rehabilitation on post mandibular resection with combination of hollow obturator and hybrid prosthesis

    Directory of Open Access Journals (Sweden)

    Arif Rachman

    2009-06-01

    Full Text Available Background: Replacing tooth lost caused by caries, periodontal disease, trauma and neoplasm including ameloblastoma which requires mandibular resection is important. Purpose: The aim of the study to rehabilitation of post mandibular resection with combination of hollow obturator and hybrid prosthesis. Case: A patient 25 years old, male, for having prosthesis to cover defect due to post right mandibular resection. Case Management: In this presented case, mandibular plate was applied due to spreading defect with losing almost a half body of mandible (class II modification 2 according to cantor and curtis classification. The design of therapy was mandibular obturator using hybrid prosthesis (removable partial denture metal frame and fixed splint crown with precision attachment with hollow obturator. The application was based on several advantages: good aesthetic performance, retention, stability, lighter weight and equal share of vertical load for teeth on non surgical site. The result of control I, II, III, showed that aesthetic performance, masticatory function, speech and swallowing were in good condition. Conclusion: The design of mandibular obturator using hybrid denture with hollow obturator could rehabilitate aesthetic performance, masticatory function, speech and swallowing for patient with post mandibular resection.

  8. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study

    OpenAIRE

    Hiremath, Mallayya C.; Srivastava, Pooja

    2016-01-01

    Purpose: The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. Materials and Methods: A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presenc...

  9. Application of palatal RB obturator in babies with isolated palatal cleft

    Directory of Open Access Journals (Sweden)

    Radojičić Julija

    2009-01-01

    Full Text Available Background. Isolated cleft of secondary palate has a specific clinical picture due to a wide communication between the mouth and nose cavity. As a consequence of that, babies born with this malformation are often subject to infections of the upper bronchial tubes, middle ear, speech disorders, and certainly the most difficult existential problem they face at the very beginning of their lives, the impossibility of suckling (breast feeding. Such babies have to be fed with gastric probe. The difficulties in their nutrition have often been described in literature, yet a singular attitude toward early orthodontic therapy has not been adopted still. The aim of the paper was to describe a design and application of obturator immediately after the birth of a baby with isolated palatal cleft, and the role in feeding. Case report. We presented a female neonate, born on 27th December 2007, with a wide fissure in the shape of the letter U over the entire secondary palate. The baby was referred to the Stomatology Clinic due to nutrition impossibility. To avoid feeding with gastric probe, the formation of RB obturator was performed (artificial palate. Hereby, the procedure of obturator making with an explanation of its function is presented. Conclusion. The application of RB obturator and the necessary education of parents have a major role in shortening the time of breast feeding and increasing the amount of food intake and, thus, for the normal growth and development of newborn infants with isolated palate cleft.

  10. Inhibition of Apical Root Resorption by Calcium Hydroxide During Orthodontic Treatment: A Case Report

    OpenAIRE

    Pacheco, Cinthia Mara da Fonseca; Pacheco, Daniela da Fonseca; Motta, Patrícia Gonçalves da

    2016-01-01

    Apical root resorption is a common outcome of orthodontic treatment. The present article reports a case of absence of apical root resorption in a left maxillary lateral incisor filled with calcium hydroxide paste throughout orthodontic movement. After orthodontic treatment was completed the tooth was subsequently obturatedwith gutta-percha and the patient followed for 18 months. The presence of a periapical lesion and the properties of calcium hydroxide as a root resorption inhibitor were dec...

  11. Bowel obstruction in obturator hernia: A challenging diagnosis

    Directory of Open Access Journals (Sweden)

    L. Conti

    2018-01-01

    Conclusion: Obturator hernia is a rare type of hernia due to his diagnosis, which is often unclear; a prompt suspect based for the non-specific symptoms is crucial for the diagnosis. Surgical management depends on early diagnosis and it is the only possible treatment for this pathology.

  12. A method for obturating microscopic ports in parts submitted to stresses, e.g. heat-exchangers

    International Nuclear Information System (INIS)

    Halstead, W.D.

    1975-01-01

    The invention relates to the obturation of cracks in metal-parts. It refers to a method for obturating the micropores of a member adapted to be submitted to stresses, said method being characterized in that it comprises the steps of exposing one surface of said member to a mixture of nickel-carbonyl and hydrogen sulfide with an inert gaseous carrier, and exposing the member other surface to air or nitrogen with oxygen or steam, the gases being at substantially the same pressure and at a temperature of from 290 to 330 deg K. This can be applied to the obturation of micropores in the heat exchangers of sodium cooled nuclear reactor [fr

  13. Outcome of zinc oxide eugenol paste as an obturating material in primary teeth pulpectomy: A systematic review

    Directory of Open Access Journals (Sweden)

    Harsha S Nalawade

    2017-01-01

    Full Text Available The aim of this systematic review is to use the principles of evidence-based dentistry to evaluate the outcome of zinc oxide eugenol (ZOE paste as an obturating material in primary teeth pulpectomies. Moderate-to-high success rates are reported with ZOE in preserving chronically infected primary teeth. However, it fails to meet many of the criteria for an ideal obturating material. Databases searched were PubMed, EBSCOhost, and Google Scholar. Articles published between January 1, 1993, and June 30, 2016, with in vivo studies for obturating materials in primary teeth pulpectomy with placement of preformed crown, reporting follow-up period of at least 12 months with clinical and radiographic success rates were selected for this review. In total, 122 articles were retrieved. After the removal of duplicates and screening, full-text articles were analyzed; of which eight articles were selected for the systematic review. No significant difference was seen in the outcome of obturating materials used in comparison with ZOE in the included studies. Outcomes of ZOE paste obtained with clinical and radiographic evaluation were similar when compared to the newer combinations of materials available for obturating primary teeth today. More number of randomized controlled clinical trials for primary teeth pulpectomies with at least 12 months follow-up period and placement of crown as final restoration need to be carried out for testing the newer materials in comparison with ZOE to conclude a suitable alternative obturating material.

  14. Radiographic evaluation of furcal perforations sealed with different materials in dogs' teeth

    Directory of Open Access Journals (Sweden)

    José Roberto Vanni

    2011-08-01

    Full Text Available OBJECTIVE: The objective of this work was to evaluate, using radiographic images, the behavior of four materials used to repair root perforations in dogs' teeth. Material and METHODS: Second and third premolars of 6 dogs were used. The 48 teeth were randomly divided into 4 groups (n=12 and the perforations were sealed with one of the following materials: MTA, AH Plus, Vitremer and gutta-percha. Dogs were submitted to general anesthesia, teeth were radiographed and pulp was accessed. Perforations were done, at the maximum curve of the pulp floor, sealed and the accessed coronal cavity was filled with glass ionomer cement (Vidrion R. After 90 days, the dogs were sacrificed and the last x-ray image was taken. Images were analyzed for the presence/absence of periodontal lesions at the perforation region. Data were analyzed statistically by chi-square test at 5% significance level. RESULTS: There were no statistically significant differences (p>0.05 among AH Plus, Vitremer and gutta-percha groups. MTA produced the smallest number of periodontal lesions (p<0.05. CONCLUSIONS: It may be concluded that none of the tested materials was able to preserve the integrity of the periodontal tissues in the furcation region, and the use of MTA resulted in the least formation of adjacent periodontal bone lesions revealed by the radiographic comparisons.

  15. Comparison of the Effect of Canal Preparation by Step Back Technique Using Hand Instruments and Gates Glidden Drills with ProTaper Universal Rotary System on the Root Resistance to Vertical Fracture

    Directory of Open Access Journals (Sweden)

    A Abbaszadegan

    2013-06-01

    Full Text Available Introduction: Cleaning and shaping of the root canal system with an efficient and safe technique are the major goals of root canal treatment. The aim of this study was to compare the conventional root canal preparation technique by hand instruments and Gates Glidden drills with ProTaper Universal Rotary system on the root susceptibility to vertical fracture. Methods: Thirty extracted human mandibular premolars were randomly assigned to two groups. In group I, apical preparation was performed with k-files up to #40 utilizing step back technique and coronal flaring was done with Gates Glidden drills. In group II, ProTaper Universal Rotary instruments were used up to the file F4. All teeth were obturated with lateral compaction technique using gutta-percha and AH26 sealer. A simulated periodontal ligament was fabricated, and the teeth were mounted. A stainless steel finger spreader #35 was mounted in an Instron testing machine and the necessary load to cause a root fracture was inserted and recorded. The obtained data were analyzed statistically using T-test. Results: The force required to fracture was significantly lower for the roots prepared by ProTaper instruments in comparison with the specimens prepared by hand instruments and Gates Glidden drills (P< 0.001. Conclusion: Canal preparation with ProTaper rotary instruments can make the roots more susceptible to vertical fracture than traditional instrumentation with k-files and Gates Glidden drills.

  16. A comparative In vivo efficacy of three spiral techniques versus incremental technique in obturating primary teeth

    Directory of Open Access Journals (Sweden)

    Shalini Chandrasekhar

    2018-01-01

    Full Text Available Background: The aim of this study was to evaluate the efficiency of four different obturating techniques in filling the radicular space in primary teeth. Materials and Methods: This clinical trial was carried out on 34 healthy, cooperative children (5–9 years who had 63 carious primary teeth indicated for pulpectomy. They were divided into four groups, such that in each group, a total of 40 canals were allotted for obturation with respective technique. The root canals of selected primary teeth were filled with Endoflas obturating material using either bi-directional spiral (Group 1; incremental technique (Group 2, past inject (Group 3 or lentulo spiral (Group 4 according to the groups assigned. The effectiveness of the obturation techniques was assessed using postoperative radiographs. The assessment was made for a depth of fill in the canal, the presence of any voids using Modified Coll and Sadrian criteria. The obtained data were analyzed by using ANOVA test and unpaired t-test. Results: Bi-directional spiral and lentulo spiral were superior to other techniques in providing optimally filled canals (P< 0.05. The bi-directional spiral was superior to lentulo spiral in preventing overfill (P< 0.05. Conclusion: Based on the present study results, bi-directional spiral can be recommended as an alternate obturating technique in primary teeth.

  17. Evaluation of apical microleakage of teeth sealed with four different root canal sealers Avaliação da microinfiltração apical em dentes obturados com quatro diferentes cimentos endodônticos

    Directory of Open Access Journals (Sweden)

    Fábio Dultra

    2006-10-01

    Full Text Available OBJECTIVES: to compare the apical sealing ability of four root canal sealers. MATERIAL AND METHODS: forty extracted human maxillary canines were instrumented 1 mm short of the anatomical apex and randomly assigned to four groups (n=10, according to the root canal sealer used for obturation: Endofill, AH Plus, EndoREZ and Epiphany. Root canals were obturated with gutta-percha points, except for the Epiphany group, in which resin points (Resilon were used. The teeth were immersed in India ink for seven days and clarified using methyl salicylate. The extent of apical dye penetration was measured with a measuroscope in all aspects of the canal. RESULTS: AH Plus (0.02 mm ± 0.07, Epiphany (0.00 mm ± 0.00 and EndoREZ (0.32 mm ± 0.62 did not differ statistically to each other (p>0.01. EndoFill presented the highest dye penetration mean (0.83 mm ± 0.73 and was statistically different from the other sealers (pOBJETIVOS: comparar a capacidade de selamento apical de quatro cimentos endodônticos. MÉTODOS: quarenta caninos superiores humanos extraídos foram instrumentados 1 mm aquém do ápice anatômico e distribuídos aleatoriamente em quatro grupos (n=10, de acordo com o cimento endodôntico utilizado para a obturação: Endofill, AH Plus, EndoREZ e Epiphany. Os canais radiculares foram obturados pela técnica da condensação lateral com os cimentos e com cones de guta-percha, exceto o grupo do Epiphany, no qual os cones de resina (Resilon foram utilizados. Os dentes foram imersos em nanquim por sete dias e submetidos ao processo de diafanização e, então, clarificados empregando-se o salicilato de metila. A extensão de penetração via apical do corante foi medida por meio de um microscópio de mensuração em todas as faces do terço apical. RESULTADOS: AH Plus (0,02 mm ± 0,07, Epiphany (0,00 mm ± 0,00 e EndoREZ (0,32 mm ± 0,62 não diferiram estatisticamente entre si (p>0,01. EndoFill apresentou a maior média de penetração do corante (0

  18. The role of succinylcholine in the prevention of the obturator nerve reflex during transurethral resection of bladder tumors

    International Nuclear Information System (INIS)

    Cesur, M.; Erdem, Ali F.; Alici, Haci A.; Yuksek, Mustafa S.; Yapanoglu, T.; Aksoy, Y.

    2008-01-01

    Objective was to present our 8 year experience in the prevention of the obturator nerve reflex during transurethral resection of bladder tumors. This study was performed in Ataturk University Hospital between 1999 and 2007. We retrospectively reviewed the records of 89 patients with inferolateral bladder tumors, who underwent transurethral resection under epidural or general anesthesia and requested obturator nerve reflex inhibition. Epidural anesthesia was administered to 57 patients, while the remaining 32 patients underwent general anesthesia via mask; and succinylcholine was administered prior to resection. Of the 57 patients received epidural anesthesia, 18 were diagnosed as inferolateral bladder tumors during endoscopy and had to undergo general anesthesia. Obturator nerve block was attempted preoperatively in 39 patients. However, a nerve identification failure, hematoma and 4 obturator nerve reflex events, despite the block, were observed and these patients were subjected to general anesthesia with succinylcholine. Fifty-six patients (32 patients initially had general anesthesia and 24 converted from epidural to general anesthesia) were all given succinylcholine prior to resection. Due to its mechanisms of action, succinylcholine is completely effective and represents a simple alternative to obturator nerve block. No contraction was observed in any patient given succinylcholine. (author)

  19. Plant wealth of a sacred grove: Mallur Gutta, Telangana state, India

    Directory of Open Access Journals (Sweden)

    Suthari S

    2016-10-01

    Full Text Available Sateesh Suthari,1 Ramesh Kandagalta,2 Ajmeera Ragan,2 Vatsavaya S Raju,2 1Department of Plant Sciences, School of Life Sciences, University of Hyderabad, Hyderabad, 2Plant Systematics Laboratory, Department of Botany, Kakatiya University, Warangal, India Abstract: The Mallur Gutta (Hill of Warangal district in Telangana state, India, reputed as a habitat for medicinal plants, was inventoried from 2009 to 2015 for its plant wealth through the traditional knowledge of the local people. The Hindu temples of Lord Sri Laxminarasimha Swamy and Lord Hanuman, and the ethnic worship of mahua trees indicated it was a sacred grove which was selected as a Medicinal Plants Conservation Area. The exploration of Mallur Gutta resulted in the enumeration and documentation of plant wealth representing 470 species of 318 genera pertaining to 95 families of vascular plants. The importance of the grove as the residence for many rare or medicinal species in the state of Telangana is documented. The plant diversity is analyzed in terms of growth and life forms which indicate the prevailing microclimate, ecological opportunities and the species richness. The ecological services rendered by the Mallur Gutta forest ecosystem are documented to study how the great majority of the species are used by the ethnic and nonethnic people, and also the pilgrims who visit the shrine for its serenity. The study also identified two major threats to the conservation of hill ecosystem and the archeological site: 1 biotic pressure (the ever-increasing pilgrims, grazing by cattle, goat and sheep, the development activities taken up for the pilgrims, nondegradable litter thrown, collection of medicinal plants and widening of the pathway to the Chintamani perennial stream – the trampling and alien plant invasions of the marsh sustaining the stream; and 2 the potential for fire spreading from burning the litter. The study suggests the need to initiate remedial measures toward ecosystem

  20. Post-operative Pain Analysis between Single Visit and Two Visit Root Canal Treatments using Visual Analogue Scale: An In Vivo Study

    Directory of Open Access Journals (Sweden)

    Kavita Tarale

    2013-01-01

    Full Text Available The purpose of this clinical study was to evaluate post-operative pain, after root canal therapy, performed in one appointment versus two appointment using calcium hydroxide intracanal medicament. Study design: In this in-vivo study, 60 patients requiring root canal therapy on permanent 1st molars were included. Patients were randomly divided into two experimental and one control group. Group1: One visit therapy (n=20 Group2: Two visit therapy with 1 week of calcium hydroxide dressing (n=20 Group3(Control: Two visit therapy with 1 week of sterile dry cotton pellet dressing (n=20 Materials and method : The standard protocol for all the patients included local anaesthesia, isolation & access cavity preparation, chemomechanical preparation with Rotary Protaper NiTi instruments, and irrigation with 3% sodium hypochlorite, 17% EDTA, 0.9%saline and 2% chlorhexidine. Teeth in group1 (n=20 were obturated on the same appointment using single cone technique (6% gutta percha points and AH Plus sealer. Teeth in group 2(n=20 and group 3(n=20 were given a dressing of calcium hydroxide and dry cotton pellet respectively for a week followed by double seal with Cavit G and IRM. These teeth were obturated on the 2nd appointment using same material and techniques as in group 1. Teeth in all three groups were restored with dual cure composite resin. A modified Visual Analogue Scale was used to measure preoperative pain and postoperative pain after 6, 12, 24 & 48hrs interval. Statistical analysis was performed using an independent-sample t test. There was no statistically significant difference between groups at any of the four postoperative intervals. There was no significant difference among all the three groups studied after 12, 24hrs & 48hrs. Conclusion : Within the limitations of this in vivo study, it may be concluded that Single Visit Endodontics provides excellent results, if care in diagnosis and proper case selection is given importance. Calcium hydroxide

  1. Sealing ability of hydroxyapatite as a root canal sealer: in vitro study

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2007-09-01

    Full Text Available Hydroxyapatite (HA is the most thermodynamically synthetic calcium phosphate cement, and has indicated useful as a sealer because can seal a furcation perforation, is shown to be biocompatible and also has potential to promote the healing of bone in endodontic therapy. The objective of this study is to determine the sealing ability of HA produced by School of Engineering, Universiti Sains Malaysia (USM when used as a sealer in root canal obturation, compare with Tubli-seal (Zinc-Oxide base and Sealapax (Calcium Hydroxyde base sealers. Forty five single rooted human anterior teeth were instrumented and randomly divided into three experimental groups of 15 teeth each. All teeth in the experimental groups were obturated with laterally condensed gutta percha technique. Teeth in the first group were sealed using Zinc-Oxide (ZnO based sealer and those of second group using Calcium Hydroxide (CaOH based root canal sealer. Third experimental group was sealed using HA from School of Engineering USM. Teeth were then suspended in 2% methylene blue. After this, teeth were demineralized dehydrated and cleared. Linear dye penetration was determined under magnifying lense with calibrated eye piece. Statistical analyses of the linear dye penetration were performed with Kruskal Wallis test. The intergroup comparison between HA and ZnO groups and CaOH groups were analyzed by Mann-Whitney test. The dye penetration for group which were sealed with HA exhibited the lowest penetration and it showed that there was a statistically significant difference both between HA and ZnO groups and also between HA and CaOH groups (p < 0.001.In conclusion, it was found that value added HA based endodontic material which were produced by USM can be used as a root canal sealing materials when it used in combination with epoxy resin since it leaked comparatively less as compared to ZnO and CaOH sealers. Before reaching a definitive conclusion, this material requires further extensive

  2. Multidomain multiphase fluid mechanics

    International Nuclear Information System (INIS)

    Sha, W.T.; Soo, S.L.

    1976-10-01

    A set of multiphase field equations--conversion of mass, momentum and energy--based on multiphase mechanics is developed. Multiphase mechanics applies to mixtures of phases which are separated by interfaces and are mutually exclusive. Based on the multiphase mechanics formulation, additional terms appear in the field equations when the physical size of the dispersed phase (bubble or droplet) is many times larger than the inter-molecular spacing. These terms are the inertial coupling due to virtual mass and the additional viscous coupling due to unsteadiness of the flow field. The multiphase formulation given here takes into account the discreteness of particles of dispersed phases and, at the same time, the necessity of the distributive representation of field variables via space-time averaging when handling a large number of particles. The provision for multidomain transition further permits us to treat dispersed phases which are large compared to the characteristic dimension of the flow system via interdomain relations. The multidomain multiphase approach provides a framework for us to model the various flow regimes. Because some of the transport parameters associated with the system equations are not well known at the present time, an idealized two-domain two-phase solution approach is proposed as a first step. Finally, comparisons are made between the field equations formulated based on the multidomain-multiphase fluid mechanics and the pertinent existing models, and their relative significances are discussed. The desirability of consistent approximation and simplifications possible for dilute suspensions are discussed

  3. [Effects of qishenyiqi gutta pills on calcium/calmodulin dependent protein kinase II in rats with renal hypertension].

    Science.gov (United States)

    Zhang, Xiao-ying; Wei, Wan-lin; Shu, Chang-cheng; Zhang, Ling; Tian, Guo-xiang

    2013-02-05

    To explore the effects of qishenyiqi gutta pills on myocardial hypertrophy of left ventricle and calcium/calmodulin dependent protein kinase II (CAMK II) in rats with renal hypertension and elucidate its intervention mechanism for myocardial hypertrophy. A total of 50 Wistar rats were randomly divided into 5 groups of sham-operation, control, high-dose qishenyiqi gutta pills, low-dose qishenyiqi gutta pills and valsartan (n = 10 each). The rat model of myocardial hypertrophy with renal hypertension was established by the 2-kidney 1-clip (2K1C) method. The experimental animals were divided into control, high-dose, low-dose and valsartan groups. At Week 5 postoperation, valsartan group received an oral dose of valsartan (30 mg×kg(-1)×d(-1)), high-dose and low-dose groups took qishenyiqi gutta pills (250 and 125 mg×kg(-1)×d(-1)) while sham-operation and control groups had the same dose of normal saline solution. Tail arterial pressure was detected weekly and continued for 8 weeks. At the end of Week 12, the animals were sacrificed to harvest myocardial tissue of left ventricle for detecting left ventricular mass index (LVMI). The collagen volume fraction (CVF) of myocardium was examined by Van Gieson staining, the activities of superoxide dismutase (SOD) and reactive oxygen species (ROS) were detected by enzyme-linked immunosorbent assay (ELISA) and the expression of CAMK II was detected by immunohistochemistry and Western blot. (1) Blood pressures were significantly higher in high-dose, low-dose and control groups than those in sham-operation and valsartan groups ((167.66 ± 11.48), (166.72 ± 13.51), (174.34 ± 14.52) vs (119.57 ± 6.30), (131.80 ± 12.49) mm Hg, P pills may retard myocardial hypertrophy of left ventricle in rats with renal hypertension. And the mechanism is probably be correlated with its antioxidant activity and inhibited expression of myocardial CAMK II.

  4. REHABILITATION OF A HEMI-MAXILLECTOMY PATIENT WITH A CAST PARTIAL OBTURATOR PROSTHESIS - A CLINICAL REPORT.

    OpenAIRE

    Aprajita; Atul Bhatnagar; Kumari Deepika; Shankar singh.

    2018-01-01

    Prosthodontic rehabilitation of patient who have underwent maxillectomy surgery is a challenging task. Achieving optimum stability, retention and support are the major problems. An obturator with cast partial design is used to rehabilitate maxillectomy defect. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissues and to provide comfort, function, and aesthetics to the patients. This case report describes several steps of fabrication of a definitive obtu...

  5. Multiphase Flow Dynamics 2 Mechanical Interactions

    CERN Document Server

    Kolev, Nikolay Ivanov

    2012-01-01

    Multi-phase flows are part of our natural environment such as tornadoes, typhoons, air and water pollution and volcanic activities as well as part of industrial technology such as power plants, combustion engines, propulsion systems, or chemical and biological industry. The industrial use of multi-phase systems requires analytical and numerical strategies for predicting their behavior. .In its fourth extended edition the successful monograph package “Multiphase Flow Daynmics” contains theory, methods and practical experience for describing complex transient multi-phase processes in arbitrary geometrical configurations, providing a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics. In the present second volume the methods for describing the mechanical interactions in multiphase dynamics are provided. This fourth edition includes various updates, extensions, improvements and corrections.   "The literature in the field of multiphase flows is numerous. Therefore, it i...

  6. Multiphase flow dynamics 1 fundamentals

    CERN Document Server

    Kolev, Nikolay Ivanov

    2004-01-01

    Multi-phase flows are part of our natural environment such as tornadoes, typhoons, air and water pollution and volcanic activities as well as part of industrial technology such as power plants, combustion engines, propulsion systems, or chemical and biological industry. The industrial use of multi-phase systems requires analytical and numerical strategies for predicting their behavior. In its third extended edition this monograph contains theory, methods and practical experience for describing complex transient multi-phase processes in arbitrary geometrical configurations, providing a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics. In the present first volume the fundamentals of multiphase dynamics are provided. This third edition includes various updates, extensions and improvements in all book chapters.

  7. Effects of sociodemographic, treatment variables, and medical characteristics on quality of life of patients with maxillectomy restored with obturator prostheses.

    Science.gov (United States)

    Artopoulou, Ioli Ioanna; Karademas, Evangelos C; Papadogeorgakis, Nikolaos; Papathanasiou, Ioannis; Polyzois, Gregory

    2017-12-01

    Restoration of maxillary defects resulting from tumor ablative surgery presents a difficult challenge, with both functional and esthetic issues. Whether rehabilitation with an obturator prosthesis could significantly contribute to improved quality of life in patients with maxillary resection has been scarcely studied, with relatively small study samples. The purpose of this survey study was to assess the overall functioning of the obturator prosthesis and the effect of specific sociodemographic, medical, and treatment variables on obturator functioning and quality of life in patients with maxillectomy. Global quality of life (QOL) and satisfaction with the obturator prosthesis of 57 patients who underwent maxillectomy and prosthetic rehabilitation at the National and Kapodistrian University of Athens were assessed using 3 questionnaires: European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire C30 (QLQ-C30), the EORTC QLQ-HN35, and the obturator functioning scale. The data were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks, hierarchical multiple regression analysis, and the Spearman rank order correlation (α=.05). Satisfactory functioning of the obturator prosthesis was the most significant predictor of improved QOL (Pmaxillectomy defect (Pmaxillectomy defect had a significant effect on QOL but did not influence the functional outcome. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Modeling multiphase materials processes

    CERN Document Server

    Iguchi, Manabu

    2010-01-01

    ""Modeling Multiphase Materials Processes: Gas-Liquid Systems"" describes the methodology and application of physical and mathematical modeling to multi-phase flow phenomena in materials processing. The book focuses on systems involving gas-liquid interaction, the most prevalent in current metallurgical processes. The performance characteristics of these processes are largely dependent on transport phenomena. This volume covers the inherent characteristics that complicate the modeling of transport phenomena in such systems, including complex multiphase structure, intense turbulence, opacity of

  9. Rehabilitation of Posterior Maxilla with Obturator Supported by Zygomatic Implants

    Directory of Open Access Journals (Sweden)

    Sankalp Mittal

    2018-01-01

    Full Text Available Prosthetic rehabilitation of atrophic maxilla and large maxillary defects can be done successfully by zygomatic implant-supported prosthesis. Zygomatic implants are an avant-garde to complex and invasive-free vascularised osteocutaneous flaps, distraction osteogenesis, and the solution to flap failures. A treated case of tuberculous osteomyelitis, with a class II (Aramany’s classification maxillary defect, reported to oral maxillofacial department, Government Dental College (RUHS-CODS. The defect in this group was unilateral, retaining the anterior teeth. The patient was previously rehabilitated with a removable maxillary obturator. Inadequate retention affected essential functions like speaking, mastication, swallowing, esthetics, and so on due to lack of sufficient supporting tissues. A fixed prosthetic rehabilitation of posterior maxillary defect was done with obturator supported with two single-piece zygomatic implants. At 1-year follow-up, the patient was comfortable with the prosthesis, and no further complaints were recorded.

  10. Management of maxillectomy defect with a hybrid hollow bulb obturator

    Science.gov (United States)

    Singh, Kamleshwar; Singh, Saumyendra V; Mishra, Niraj; Agrawal, Kaushal Kishor

    2013-01-01

    A woman having already undergone maxillectomy came to the department complaining of difficulty in eating and speech. During the construction of an obturator, the bulb area should be hollowed to reduce weight so that the teeth and supporting tissues are not stressed unnecessarily. The conventional open design drains fluid from the adjacent mucosa, possibly increasing the weight of the prosthesis, and is difficult to clean. The closed bulb design does not drain secretions and may cause obstruction and susceptibility to infection in the paranasal and pharyngeal regions, though it is easier to maintain. An alternative to the two designs, combining their advantages, is presented in this report. As the open hollow part of the obturator was shallow, it was easy to clean. Making the inferior part of the bulb hollow and closed led to a reduction in the overall weight of the prosthesis while increasing its resonance. PMID:23436886

  11. Modified snap-on attachment with ′O-ring′ for two piece hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    C Gunasekar

    2013-01-01

    Full Text Available Restoration of near normal functions in patients who have been treated with hemimaxillectomy is generally difficult, in view of the restriction in mouth opening following healing of large surgical wound. Further, the extent and nature of the surgical defect differ from patient to patient. Thus, design of an obturator needs to be patient oriented. In this report, we describe a novel snap-on attachment with O-ring in a conventional two piece hollow bulb obturator for a 70-year-old male treated for carcinoma of the left maxilla and sinus.

  12. Accuracy and reliability of stitched cone-beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Egbert, Nicholas [Private Practice, Reconstructive Dental Specialists of Utah, Salt Lake (United States); Cagna, David R.; Ahuja, Swati; Wicks, Russell A. [Dept. of rosthodontics, University of Tennessee Health Science Center College of Dentistry, Memphis (United States)

    2015-03-15

    This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

  13. Assessment of micro-leakage for light-cure glass ionomer and pro-root mineral trioxide aggregate as coronal barriers in intracoronal bleaching of endodontically treated teeth

    Directory of Open Access Journals (Sweden)

    Maryam Zare Jahromi

    2017-03-01

    Full Text Available Introduction: Cervical root resorption is one of the most important complications of intra coronal bleaching. A way of preventing this type of resorption is using a coronal barrier under the bleaching materials. The aim of this study was to compare the sealing ability of glass ionomer cement and Pro Root Mineral Trioxide Aggregate (MTA as a coronal barrier in intra coronal bleaching. Materials &Methods: In this study, 40 single-root maxillary anterior teeth were endodontically prepared and divided into two experimental groups (n= 15 and two positive and negative control groups (n=5. In the experimental groups, gutta percha was removed up to 3 mm below the cemento enamel junction (CEJ.RMGI and MTA were placed over gutta percha up to the level of CEJ. After a 24-hour incubation period, the bleaching agent (a mixture of sodium perborate and 30% hydrogen peroxide was placed in the access cavities. The bleaching agents were replaced every 3 days over 9 days. Then, the access cavity was filled with 2% methylene blue for 48 hours. All samples were longitudinally sectioned and the dye penetration range was evaluated using a stereomicroscope. Data were statistically analyzed using Kruskal-Wallis and Mann–Whitney tests (α=0.05. Results: Leakage mean indicated that there was a significant difference between these two groups and leakage was less in ProRoot than glass ionomer. Conclusion: It seems that the MTA can provide a better coronal seal during the bleaching.

  14. Applying liquid chromatography-tandem mass spectrometry to assess endodontic sealer microleakage

    Directory of Open Access Journals (Sweden)

    André Luiz da Costa MICHELOTTO

    2015-01-01

    Full Text Available The objective of this study was to describe a new method for the quantitative analysis of a microleakage of endodontic filling materials. Forty extracted single-rooted teeth were randomly divided into three experimental groups. After root canal shaping, the experimental groups were filled using the lateral condensation technique with the Epiphany system (G1, with gutta-percha + Sealapex (G2, and with gutta-percha + AH Plus (G3. Each root was mounted on a modified leakage testing device, and caffeine solution was used as a tracer (2000 ng mL-1, pH 6.0, applied in the coronal direction towards the tooth apex, creating a hydrostatic pressure of 2.55 kPa. Presence of caffeine in the receiving solution was measured after 10, 30, and 60 days, using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS. None of the groups presented microleakage at 10 days. At 30 days, G2 and G3 showed similar infiltration patterns (means: 16.0 and 13.9 ng mL-1, respectively, whereas G1 showed significantly higher values (mean: 105.2 ng mL-1. At 60 days, leakage values were 182.6 ng mL-1for G1, 139.0 ng mL-1 for G2, and 53.5 ng mL-1 for G3. AH Plus showed the best sealing ability and HPLC-MS/MS showed high sensitivity and specificity for tracer quantification.

  15. Accuracy and reliability of stitched cone-beam computed tomography images

    International Nuclear Information System (INIS)

    Egbert, Nicholas; Cagna, David R.; Ahuja, Swati; Wicks, Russell A.

    2015-01-01

    This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

  16. Accuracy and reliability of stitched cone-beam computed tomography images.

    Science.gov (United States)

    Egbert, Nicholas; Cagna, David R; Ahuja, Swati; Wicks, Russell A

    2015-03-01

    This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

  17. Comparative assessment of the area of sealer voids in single cone obturation done with mineral trioxide aggregate, epoxy resin, and zinc-oxide eugenol based sealers

    Directory of Open Access Journals (Sweden)

    Anisha Kumar

    2016-01-01

    Full Text Available Introduction: Voids in the sealer mass have the potential to allow leakage through obturation. They are more critical in single cone (SC obturation as the volume of sealer used in this obturation is larger when compared to other obturations. Aim: To compare the area of voids in mineral trioxide aggregate (MTA-based, resin-based, and zinc oxide-eugenol-based sealers when employed with SC obturation technique. Materials and Methods: Fifteen teeth were cleaned and shaped and divided into three groups for SC obturation using MTA Fillapex, AH26, and Pulpdent sealers, respectively. The obturated teeth were sectioned at apical, middle, and coronal third, and area of voids in the sealer was assessed using a stereomicroscope and digital images and image software. The results were statistically analyzed using SPSS software and Kruskal-Wallis and Mann-Whitney tests. Results: The three tested sealers showed voids in all the sections except MTA Fillapex, which was void free in apical and middle sections. There were significant differences between these sealers regarding their section wise area of voids (P < 0.05. Similarly, there were significant differences in their overall area of voids (P < 0.05 with MTA Fillapex showing significantly least area of voids followed by AH26. Conclusions: SC obturation with MTA Fillapex sealer, which showed void free apical and middle third sections, had significantly least area of voids in the sealer followed by the one with AH26 sealer, whereas SC obturation with Pulpdent sealer had significantly most area of voids.

  18. Clinical and radiographic evaluation of zinc oxide with aloe vera as an obturating material in pulpectomy: An in vivo study

    Directory of Open Access Journals (Sweden)

    Abhishek Khairwa

    2014-01-01

    Full Text Available Background: Pulp therapy for pulpally involved primary teeth continues to be a challenge to clinicians. One of the major areas of continued research is in the area of finding obturating materials to suit the specific properties of these teeth. Zinc oxide eugenol is used frequently in pulpectomy for the obturation of the primary teeth. Aims: To evaluate clinically and radiographically a mixture of zinc oxide eugenol and aloe vera as an obturating material. Materials and Methods: A total of 50 children, aged between 4 and 9 years, who were screened for unilateral or bilateral carious deciduous molars were studied. Out of these, 15 children were randomly selected for endodontic treatment. Obturation was done with a mixture of zinc oxide powder and aloe vera gel. Clinical and radiographic evaluation was done after 7 days, 1 month, 3 months, 6 months, and 9 months. The data were statistically analyzed. Results and Conclusion: Endodontic treatment using a mixture of zinc oxide powder and aloe vera gel in primary teeth has shown good clinical and radiographic success. A detailed observational study with longer follow-up will highlight the benefits of aloe vera in primary teeth as an obturating medium.

  19. Influence of the spatulation of two zinc oxide-eugenol-based sealers on the obturation of lateral canals

    Directory of Open Access Journals (Sweden)

    Pécora Jesus Djalma

    2002-01-01

    Full Text Available The objective of this research was to evaluate, in vitro, the importance of the correct manipulation of endodontic sealers, correlating it with flow rate and with the consequent obturation of root canals. Twenty-four human canines were prepared, 1 mm from the apex, with K-files up to size 50, by means of the step-back technique. Six lateral canals were then drilled in each tooth, with size 10 file fixed to a low-speed handpiece. The teeth were randomly divided into 4 groups, and root canals were obturated either with the EndométhasoneÒ sealer or Grossman sealer, prepared at ideal or incorrect clinical consistency. After obturation by means of the lateral condensation technique, the teeth were radiographed and evaluated as to the number of sealed lateral canals. Statistical analysis revealed significant differences (p < 0.001 between the tested sealers, and indicated the higher capacity of the well-manipulated Grossman sealer to fill lateral canals. It can be concluded that the flow rate of a sealer and its correct manipulation are very important for the satisfactory obturation of lateral canals.

  20. Root canal treatment of pulpless immature teeth using calcium hydroxide paste. Roentgenographic study

    International Nuclear Information System (INIS)

    Leite, R.M.G.V.; Abbud, R.

    1986-01-01

    Calcium hydroxide paste was used as a temporary dressing and the renewal was done each three months in the root treatment of immature teeth with open apex and necrotic pulps. Clinical and radiographic controls were made to observe foraminal closure. After that, the root canals were filled, employing the conventional technique with gutta-percha cones and zinc oxide eugenol cements. The calcium hydroxide paste was applied in the apical region before the root canal filling. The follow-up was done periodically and the cases have more than two years of control. (author) [pt

  1. Multiphase Flow Dynamics 1 Fundamentals

    CERN Document Server

    Kolev, Nikolay Ivanov

    2012-01-01

    Multi-phase flows are part of our natural environment such as tornadoes, typhoons, air and water pollution and volcanic activities as well as part of industrial technology such as power plants, combustion engines, propulsion systems, or chemical and biological industry. The industrial use of multi-phase systems requires analytical and numerical strategies for predicting their behavior. In its fourth extended edition the successful monograph package “Multiphase Flow Dynmics” contains theory, methods and practical experience for describing complex transient multi-phase processes in arbitrary geometrical configurations, providing a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics. In the present first volume the local volume and time averaging is used to derive a complete set of conservation equations for three fluids each of them having multi components as constituents. Large parts of the book are devoted on the design of successful numerical methods for solving the...

  2. Multiphase Flow Dynamics 3 Thermal Interactions

    CERN Document Server

    Kolev, Nikolay Ivanov

    2012-01-01

    Multi-phase flows are part of our natural environment such as tornadoes, typhoons, air and water pollution and volcanic activities as well as part of industrial technology such as power plants, combustion engines, propulsion systems, or chemical and biological industry. The industrial use of multi-phase systems requires analytical and numerical strategies for predicting their behavior. .In its fourth extended edition the successful monograph package “Multiphase Flow Daynmics” contains theory, methods and practical experience for describing complex transient multi-phase processes in arbitrary geometrical configurations, providing a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics. In the present third volume methods for describing of the thermal interactions in multiphase dynamics are provided. In addition a large number of valuable experiments is collected and predicted using the methods introduced in this monograph. In this way the accuracy of the methods is reve...

  3. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    Science.gov (United States)

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P maxillectomy can improve survival quality of patient.

  4. SPEECH EVALUATION WITH AND WITHOUT PALATAL OBTURATOR IN PATIENTS SUBMITTED TO MAXILLECTOMY

    Science.gov (United States)

    de Carvalho-Teles, Viviane; Pegoraro-Krook, Maria Inês; Lauris, José Roberto Pereira

    2006-01-01

    Most patients who have undergone resection of the maxillae due to benign or malignant tumors in the palatomaxillary region present with speech and swallowing disorders. Coupling of the oral and nasal cavities increases nasal resonance, resulting in hypernasality and unintelligible speech. Prosthodontic rehabilitation of maxillary resections with effective separation of the oral and nasal cavities can improve speech and esthetics, and assist the psychosocial adjustment of the patient as well. The objective of this study was to evaluate the efficacy of the palatal obturator prosthesis on speech intelligibility and resonance of 23 patients with age ranging from 18 to 83 years (Mean = 49.5 years), who had undergone inframedial-structural maxillectomy. The patients were requested to count from 1 to 20, to repeat 21 words and to spontaneously speak for 15 seconds, once with and again without the prosthesis, for tape recording purposes. The resonance and speech intelligibility were judged by 5 speech language pathologists from the tape recordings samples. The results have shown that the majority of patients (82.6%) significantly improved their speech intelligibility, and 16 patients (69.9%) exhibited a significant hypernasality reduction with the obturator in place. The results of this study indicated that maxillary obturator prosthesis was efficient to improve the speech intelligibility and resonance in patients who had undergone maxillectomy. PMID:19089242

  5. Prosthetic Rehabilitation of Maxillectomy Patient with Post-Surgical Obturator: A Case Report

    Directory of Open Access Journals (Sweden)

    Meena Kumari Mishra

    2015-07-01

    Full Text Available Case description: A 60 year old female patient presented to Department of Prosthodontics, CODS, BPKIHS, Dharan with a chief complain of loose obturator. History revealed that patient had undergone partial maxillectomy for squamous cell carcinoma 7 years back. The patient also has been wearing obturator which was loose when the patient reported to the department. On examination, the site of surgery was the maxillary right buccal sulcus area and a part of the hard palate including teeth number 11, 12, 13, 14, 15, 16, 17. The presented defect situation corresponded to a Class I situation (resection performed along the palatalmidline according to the Aramany classification of defects. The surgical site showed complete healing. A hollow-bulb obturator was fabricated for rehabilitation of the defect. Conclusion: The extensive surgical procedures necessary to eradicate cancer of the head and neck and to prevent local recurrence or regional metastasis often leave extremely large physical defects which present almost insurmountable surgical difficulties in restoring acceptable function or esthetics. The prosthesis rehabilitated the patient in terms of function by providing better masticatory efficiency, phonetics by adding resonance to the voice, hence improving the clarity of speech and also improved the esthetics of the patient. DOI: http://dx.doi.org/10.3126/jcmsn.v10i4.12976 JCMS Nepal 2014; 10(4:32-36

  6. Tooth replantation after use of Euro-Collins solution or bovine milk as storage medium: a histomorphometric analysis in dogs.

    Science.gov (United States)

    Sottovia, André Dotto; Sottovia Filho, Dagoberto; Poi, Wilson Roberto; Panzarini, Sônia Regina; Luize, Danielle Shima; Sonoda, Celso Koogi

    2010-01-01

    Euro-Collins solution was developed for the preservation of organs for transplantation, whose characteristics have raised interest for its use as a storage medium for avulsed teeth before replantation. This study evaluated histologically and morphometrically the healing process of dog teeth replanted after storage in Euro-Collins solution or bovine milk. Eighty roots of 4 young adult mongrel dogs were randomly assigned to 4 groups (n = 20) and the root canals were instrumented and obturated with gutta-percha and a calcium hydroxide-based sealer. After 2 weeks, the teeth were extracted and subjected to the following protocols: GI (negative control), replantation immediately after extraction; GII (positive control), bench-drying for 2 hours before replantation; GIII and GIV, immersion in 10 mL of whole bovine milk and Euro-Collins solution at 4 degrees C, respectively, for 8 hours before replantation. The animals were sacrificed 90 days postoperatively. The pieces containing the replanted teeth were subjected to routine processing for histologic and histometric analyses under light microscopy and polarized light microscopy. Root resorption was observed in all groups. GII exhibited the greatest loss of dental structure (P < .01), and inflammatory resorption was predominant in this group. Storage in milk showed poorer results than immediate replantation and storage in Euro-Collins solution (P < .01). The teeth stored in Euro-Collins solution presented similar extension of root resorption and periodontal ligament reorganization to those of immediately replanted teeth. The findings of this study suggest that the Euro-Collins solution is an adequate storage medium for keeping avulsed teeth for up to 8 hours before replantation.

  7. Comparative evaluation of debris extruded apically by using, Protaper retreatment file, K3 file and H-file with solvent in endodontic retreatment

    Directory of Open Access Journals (Sweden)

    Chetna Arora

    2012-01-01

    Full Text Available Aim: The aim of this study was to evaluate the apical extrusion of debris comparing 2 engine driven systems and hand instrumentation technique during root canal retreatment. Materials and Methods: Forty five human permanent mandibular premolars were prepared using the step-back technique, obturated with gutta-percha/zinc oxide eugenol sealer and cold lateral condensation technique. The teeth were divided into three groups: Group A: Protaper retreatment file, Group B: K3, file Group C: H-file with tetrachloroethylene. All the canals were irrigated with 20ml distilled water during instrumentation. Debris extruded along with the irrigating solution during retreatment procedure was carefully collected in preweighed Eppendorf tubes. The tubes were stored in an incubator for 5 days, placed in a desiccator and then re-weighed. Weight of dry debris was calculated by subtracting the weight of the tube before instrumentation and from the weight of the tube after instrumentation. Data was analyzed using Two Way ANOVA and Post Hoc test. Results : There was statistically significant difference in the apical extrusion of debris between hand instrumentation and protaper retreatment file and K3 file. The amount of extruded debris caused by protaper retreatment file and K3 file instrumentation technique was not statistically significant. All the three instrumentation techniques produced apically extruded debris and irrigant. Conclusion: The best way to minimize the extrusion of debris is by adapting crown down technique therefore the use of rotary technique (Protaper retreatment file, K3 file is recommended.

  8. Experimental and numerical determination of the mechanical response of teeth with reinforced posts

    International Nuclear Information System (INIS)

    Papadopoulos, Triantafillos; Papadogiannis, Dimitris; Mouzakis, Dionysios E; Giannadakis, Konstantinos; Papanicolaou, George

    2010-01-01

    The aim of this study was to evaluate the mechanical behavior of endodontically treated teeth restored with fiber reinforced composite posts versus titanium posts, by both experimental testing and numerical simulation (finite element analysis (FEA)). Forty maxillary central incisors were endodontically treated to a size 45 file and then obturated using gutta-percha points and sealer with the lateral condensation technique. The teeth were divided into four groups of ten teeth each. All the posts were of similar dimensions. The first group was restored using carbon fiber reinforced posts (CB), the second and third groups were restored using glass fiber reinforced posts (DP and FW, respectively), and the fourth group (control group) was restored using conventional titanium posts (PP). Half of the specimens of every group were submitted to hydrothermal cycling (2000 cycles, at 5 0 C and 55 0 C, respectively). All specimens were loaded until failure at a 45 0 angle with respect to the longitudinal axis at a crosshead speed of 0.5 mm min -1 . A two-dimensional finite element model was designed in order to simulate the experimentally obtained results. Mechanical testing revealed that teeth restored with titanium posts exhibited the highest fracture strength. Debonding of the core was the main failure mode observed in glass fiber posts, whereas vertical root fractures were observed in the titanium posts. FEA revealed that the maximum stresses were developed at the interface between the post, dentin and the composite core critical regions in all three cases. Hydrothermal cycling had no significant effect on the fracture behavior of fiber reinforced composite posts.

  9. The effect of different irrigating solutions on the push out bond strength of endodontic sealer to dentin and assessing the fracture modes: An In-vitro study

    Directory of Open Access Journals (Sweden)

    Vasundhara Shivanna

    2014-01-01

    Full Text Available Aim: To evaluate the effect of smear clear, 7% maleic acid, 10% citric acid, and 17% EDTA on the push-out bond strength of epoxy resin-based endodontic sealer to dentin. Materials and Methodos: Fifty extracted mandibular premolars were collected. After decoronation using a diamond disc and water spray to obtain approximately 14 mm long root segments, canal patency and working length were established by inserting K file #15 (Mani. The root canals were enlarged using Protaper nickel-titanium rotary instruments to size #F3 at the working length irrigating with 3 mL of 2.6% sodium hypochlorite between each file size. The roots were then randomly divided into four groups (n = 10 according to the final irrigation regimen Group1: Saline (control. Group 2: 17% EDTA, Group 3: 7% maleic acid, Group 4: 10% citric acid, Group 5: Smear clear. Obturation was done using gutta-percha with AH Plus sealer. Each root section was then subjected to a compressive load via a universal testing machine, to measure the push out bond strength followed by assessment of fracture pattern under stereomicroscope. Results: The data was collected and submitted to statistical analysis by one-way analysis of variance (ANOVA test. Group 3: NaOCl/maleic acid/distilled water showed greater bond strength (2.2+/-0.278 MPa as compared to other groups. Mixed type of bond failure was predominant. Conclusion: Removal of smear layer with maleic acid as a final rinse enhanced the adhesive ability of AH plus sealer, followed by EDTA and smear clear.

  10. Challenges in Downhole Multiphase Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Aspelund, A.; Midttveit, Oe.; Richards, A.

    1996-12-31

    Permanent downhole multi-phase monitoring (DMM) can have several advantages in field development, such as increased flexibility in the development of multi-lateral and horizontal wells, optimisation of artificial lift systems and monitoring of multi-layered wells. This paper gives an overview of existing permanent downhole measurement systems and a status of topside and subsea multi-phase flow meters (MFM). The main focus is on the challenges in downhole multi-phase measurements. Topics to be taken into consideration for realization of a downhole multi-phase meter are discussed, such as actual flow conditions occurring at the point of measurement, which quantities that need to be measured, sensor principles, data processing needs and signal transmission capability. 9 refs., 9 figs.

  11. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    Science.gov (United States)

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  12. Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses.

    Science.gov (United States)

    Miyashita, Elcio Ricardo; Mattos, Beatriz Silva Câmara; Noritomi, Pedro Yoshito; Navarro, Hamilton

    2012-05-01

    The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342). Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Case presentation of two maxillectomy patients restored with two-piece hollow bulb obturator retained using two different types of magnets

    Directory of Open Access Journals (Sweden)

    B Devi Parameswari

    2017-01-01

    Full Text Available Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  14. Case Presentation of Two Maxillectomy Patients Restored with Two-piece Hollow Bulb Obturator Retained using Two Different Types of Magnets.

    Science.gov (United States)

    Parameswari, B Devi; Rajakumar, M; Jagadesaan, N; Annapoorni, H

    2017-11-01

    Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  15. Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation:a scanning electron microscopy study

    Institute of Scientific and Technical Information of China (English)

    Jun Sang Yoo; Qiang Zhu; Kee-Yeon Kum; Seok-Woo Chang; So Ram Oh; Hiran Perinpanayagam; Sang-Min Lim; Yeon-Jee Yoo; Yeo-Rok Oh; Sang-Bin Woo; Seung-Hyun Han

    2014-01-01

    The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate (MTA) was studied by scanning electron microscopy (SEM). Single-rooted human premolars (n560) were instrumented to an apical size #50/0.06 using ProFile and treated as follows:Group 1 (n510) was filled with phosphate buffered saline (PBS);Group 2 (n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS;Group 3 (n520) was obturated orthograde with a paste of OrthoMTA (BioMTA, Seoul, Korea) and PBS;and Group 4 (n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoMTA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material (IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoMTA-filled roots (Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots (Group 4). Therefore, the orthograde obturation of root canals with OrthoMTA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization.

  16. A mass-conserving multiphase lattice Boltzmann model for simulation of multiphase flows

    Science.gov (United States)

    Niu, Xiao-Dong; Li, You; Ma, Yi-Ren; Chen, Mu-Feng; Li, Xiang; Li, Qiao-Zhong

    2018-01-01

    In this study, a mass-conserving multiphase lattice Boltzmann (LB) model is proposed for simulating the multiphase flows. The proposed model developed in the present study is to improve the model of Shao et al. ["Free-energy-based lattice Boltzmann model for simulation of multiphase flows with density contrast," Phys. Rev. E 89, 033309 (2014)] by introducing a mass correction term in the lattice Boltzmann model for the interface. The model of Shao et al. [(the improved Zheng-Shu-Chew (Z-S-C model)] correctly considers the effect of the local density variation in momentum equation and has an obvious improvement over the Zheng-Shu-Chew (Z-S-C) model ["A lattice Boltzmann model for multiphase flows with large density ratio," J. Comput. Phys. 218(1), 353-371 (2006)] in terms of solution accuracy. However, due to the physical diffusion and numerical dissipation, the total mass of each fluid phase cannot be conserved correctly. To solve this problem, a mass correction term, which is similar to the one proposed by Wang et al. ["A mass-conserved diffuse interface method and its application for incompressible multiphase flows with large density ratio," J. Comput. Phys. 290, 336-351 (2015)], is introduced into the lattice Boltzmann equation for the interface to compensate the mass losses or offset the mass increase. Meanwhile, to implement the wetting boundary condition and the contact angle, a geometric formulation and a local force are incorporated into the present mass-conserving LB model. The proposed model is validated by verifying the Laplace law, simulating both one and two aligned droplets splashing onto a liquid film, droplets standing on an ideal wall, droplets with different wettability splashing onto smooth wax, and bubbles rising under buoyancy. Numerical results show that the proposed model can correctly simulate multiphase flows. It was found that the mass is well-conserved in all cases considered by the model developed in the present study. The developed

  17. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Llopis, Eva; Schwartz, Richard B.; Bencardino, Jenny T.

    2009-01-01

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  18. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara [Corades, S.L., Majadahonda-Madrid (Spain); Massachusetts General Hospital, Division of Musculoksleletal Radiology, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Alzira (Valencia) (Spain); Schwartz, Richard B. [Longwood MRI Specialists, Brookline, MA (United States); Bencardino, Jenny T. [NYU Department of Radiology, New York, NY (United States)

    2009-11-15

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  19. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    Science.gov (United States)

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Science.gov (United States)

    Mohamed Usman, Jafar Abdulla; Ayappan, Anuroopa; Ganapathy, Dhanraj; Nasir, Nilofer Nisha

    2013-01-01

    Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator. PMID:23533823

  1. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Directory of Open Access Journals (Sweden)

    Jafar Abdulla Mohamed Usman

    2013-01-01

    Full Text Available Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator.

  2. Multiphase flow dynamics 1 fundamentals

    CERN Document Server

    Kolev, Nikolay Ivanov

    2015-01-01

    In its fifth extended edition the successful monograph package “Multiphase Flow Dynamics” contains theory, methods and practical experience for describing complex transient multi-phase processes in arbitrary geometrical configurations, providing a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics. In the present first volume the local volume and time averaging is used to derive a complete set of conservation equations for three fluids each of them having multi components as constituents. Large parts of the book are devoted on the design of successful numerical methods for solving the obtained system of partial differential equations. Finally the analysis is repeated for boundary fitted curvilinear coordinate systems designing methods applicable for interconnected multi-blocks. This fifth edition includes various updates, extensions, improvements and corrections, as well as  a completely new chapter containing the basic physics describing the multi-phase flow in tu...

  3. Shock tube Multiphase Experiments

    Science.gov (United States)

    Middlebrooks, John; Allen, Roy; Paudel, Manoj; Young, Calvin; Musick, Ben; McFarland, Jacob

    2017-11-01

    Shock driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching practical applications in engineering and science. The instability is present in high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase interface is impulsively accelerated by the passage of a shockwave. It is similar in development to the Richtmyer-Meshkov (RM) instability however, particle-to-gas coupling is the driving mechanism of the SDMI. As particle effects such as lag and phase change become more prominent, the SDMI's development begins to significantly deviate from the RM instability. We have developed an experiment for studying the SDMI in our shock tube facility. In our experiments, a multiphase interface is created using a laminar jet and flowed into the shock tube where it is accelerated by the passage of a planar shockwave. The interface development is captured using CCD cameras synchronized with planar laser illumination. This talk will give an overview of new experiments conducted to examine the development of a shocked cylindrical multiphase interface. The effects of Atwood number, particle size, and a second acceleration (reshock) of the interface will be discussed.

  4. Prosthetic Rehabilitation by Palatal Hollow Bulb Obturator with Cast Metal Denture Base: A Case Report

    Directory of Open Access Journals (Sweden)

    George Francis

    2015-01-01

    Full Text Available Background: Prosthetic reconstruction of partial maxillectomy defects is a challenging procedure that requires multidisciplinary expertise to achieve an acceptable function, speech and esthetics. This procedure improves the quality of life for the patient as a normal individual. Obturation of the defect depends on its volume and position of remaining hard and soft tissues which determine the retention, stability and support for the prosthesis. The prosthesis should be simple to handle, easy to maintain, biocompatible, light in weight and convenient for future adjustments. This case report describes a clinical case of partial maxillectomy which was successfully rehabilitated with a definitive closed hollow bulb obturator and cast metal denture base.

  5. Aesthetic rehabilitation of a patient with an anterior maxillectomy defect, using an innovative single-step, single unit, plastic-based hollow obturator

    Directory of Open Access Journals (Sweden)

    Vishwas Bhatia

    2015-06-01

    Full Text Available What could be better than improving the comfort and quality of life of a patient with a life-threatening disease? Maxillectomy, the partial or total removal of the maxilla in patients suffering from benign or malignant neoplasms, creates a challenging defect for the maxillofacial prosthodontist when attempting to provide an effective obturator. Although previous methods have been described for rehabilitation of such patients, our goal should be to devise one stage techniques that will allow the patient an improved quality of life as soon as possible. The present report describes the aesthetic rehabilitation of a maxillectomy patient by use of a hollow obturator. The obturator is fabricated through a processing technique which is a variation of other well-known techniques, consisting of the use of a single-step flasking procedure to fabricate a single-unit hollow obturator using the lost salt technique. As our aim is to aesthetically and functionally rehabilitate the patient as soon as possible, the present method of restoring the maxillectomy defect is cost-effective, time-saving and beneficial for the patient.

  6. An ex vivo comparison of pressures within dental pulp space using conventional anesthetic technique versus needle-mounted obturator.

    Science.gov (United States)

    Grubbs, S Lee; Alley, Larry W; Eleazer, Paul D

    2014-07-01

    The intrapulpal (IP) injection technique is 1 of several ways of obtaining profound anesthesia. There is evidence to suggest that pressure is the primary factor in obtaining anesthesia using IP injection. This is an ex vivo comparison of pressures within dental pulp space using the conventional anesthetic technique versus a needle-mounted obturator technique. Twenty extracted anterior and premolar teeth were accessed with a high-speed 169L bur. A saline-filled tube connected to a digital pressure gauge was attached to the apical 10 mm of each tooth in a fixed mount. One operator performed all the injections under moderate pressure. Each tooth was injected twice; first, the tooth was given an IP injection with a normal setup, and then the same tooth was given an IP injection with the modified obturator syringe. The pressure at the apex was recorded for each tooth. A paired sample t test was completed to determine statistical significance. The pressure generated was considerably higher for the obturator group in every tooth when compared with the normal group (P < .001). IP injection with the obturator resulted in increased pressure at the apex of each tooth. This pressure increase may allow for increased anesthesia when IP injections are indicated. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Neurofibroma involving obturator nerve mimicking an adnexal mass: a rare case report and PRISMA-driven systematic review.

    Science.gov (United States)

    Chao, Wei-Ting; Liu, Chia-Hao; Chen, Yi-Jen; Wu, Hua-Hsi; Chuang, Chi-Mu; Wang, Peng-Hui

    2018-02-09

    Pelvic masses are a common gynecologic problem, and majority of them are diagnosed as ovarian tumors finally. Sometimes, it is hard to distinguish the origin of these pelvic masses. The following case is a solitary neurofibroma arising from the right-side obturator nerve, which was impressed as a right-side ovarian tumor initially. We reported this case, and also performed a PRISMA-driven systematic review to summary the similar cases in the literature. This review includes image, molecular and pathological findings and outcome of neurofibroma. A 33-year-old woman with a regular menstrual period denied any symptoms or signs. During her physical check-up, image examination revealed a right-side heterogeneous pelvic mass; it was suggestive of a complex of right-side ovarian tumor. A provisional diagnosis of retroperitoneal pelvic mass, probably a benign ovarian tumor, was made. Excision of the right-side pelvic mass was performed. We sent the specimens for frozen pathology, which indicated neurofibroma and lipomatous tumor and that the possibility of liposarcoma cannot be excluded. A segment of the obturator nerve was attached to the tumor and was severed. A right-side obturator nerve tear during tumor excision was observed, and a neurosurgeon was consulted for obturator nerve grafting and repair. The patient complained of mild weakness and paresthesia affecting the right leg, and we consulted a rehabilitation doctor for neuron injury. The patient's recovery was uneventful, and she was discharged eight days after the drain was removed. Further rehabilitation treatment was arranged. A neurofibroma is an uncommon pelvic retroperitoneal tumor, and it can be misdiagnosed as an adnexal mass. To our knowledge, this is a rare case of a solitary neurofibroma arising from the obturator nerve. It usually does not have any neurological deficit. We present this case to demonstrate that pelvic neurofibroma can be mistaken for an adnexal mass. This fact should be borne in mind

  8. Obturator Neuralgia: A Rare Complication of Tension-free Vaginal Tape Sling-Complete Resolution After Laparoscopic Tension-free Vaginal Tape Removal.

    Science.gov (United States)

    Miklos, John R; Moore, Robert D; Chinthakanan, Orawee

    2015-01-01

    To show a technique of retropubic tension-free vaginal tape (TVT) removal using both a transvaginal and laparoscopic approach in the treatment of a rare condition, obturator neuralgia. A step-by-step explanation of the patient's condition, diagnosis, surgical technique, and postoperative results using video, pictures, and medical illustrations (education video). TVT retropubic slings have become the gold standard for the treatment of stress urine incontinence over the last decade. Despite high cure rates, the TVT is not without potential complications. Typical complications include urine retention, incomplete bladder emptying, frequency, urgency, urethral erosion, vaginal extrusion, vaginal pain, and dyspareunia. The most common complication for sling removal/revision is chronic pain. The TVT obturator neuralgia is a rare and specific type of chronic pain that is normally associated with transobturator tape slings. The purpose of this video is to present an extremely rare complication of TVT retropubic slings, present symptoms and signs of obturator nerve compression, show the normal and the actual position of this patient's TVT sling, describe the laparoscopic removal of the TVT sling, and present the postoperative course and resolution of the patient's pain. The patient signed a release for her video to be used for educational and teaching purposes. A combined transvaginal and laparoscopic approach in a patient with lower abdominal, levator, and obturator-type pain after a TVT retropubic procedure. In patients suffering from obturator neuralgia after a retropubic sling, surgeons should include the sling as a potential causative factor in the differential diagnosis. Surgeons should consider removing the sling based on the patient's symptoms. If the patient suffers from only vaginal pain and dyspareunia, then the surgeon should consider only the removal of the vaginal portion of the sling. In patients with obturator neuralgia, retropubic, and/or lower abdominal

  9. Obturator with soft liner in the management of hard palate defect: A ...

    African Journals Online (AJOL)

    Maxillary defects are created following surgical treatment of patients with congenital defects, trauma, or neoplasm. Oral cancer is one of the more common malignanciesif detected lately massive tissues will be excised surgically and correction will be challenging. One of the treatment strategies is obturator, the retention of ...

  10. Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

    Science.gov (United States)

    Bogdanoff, David W.; Wilder, Michael C.

    2013-01-01

    For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

  11. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    Science.gov (United States)

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  12. In vitro comparison of coronal microleakage of four temporary restorative materials used in endodontic treatment

    Directory of Open Access Journals (Sweden)

    Shahi Sh.

    2008-10-01

    Full Text Available "nBackground and Aim: The use of proper temporary restorative materials between appointments is critical in successful root canal treatment. The purpose of this study was to compare the coronal microleakage of four temporary restorative materials including Zonalin, Zamherir, Coltosol and IRM. "nMaterials and Methods: In this in vitro study, standard access cavities were prepared in 120 intact extracted maxillary and mandibular human first molars. Canal preparation was carried out by the step-back technique, and obturation was performed with gutta-percha and AH26 sealer using the lateral condensation technique. Teeth were randomly divided into 4 experimental groups of 25 teeth each and two positive and negative control groups, each containing 10 teeth. In each experimental group the access cavity was restored with one of the tested materials (Zamherir, Zonalin, IRM and Coltosol. In the negative control group the access cavity was filled entirely with sticky wax and in the positive control group no restorative material was applied. Dye penetration technique was used to evaluate microleakage which was measured under a stereomicroscope. Data were analyzed with one way ANOVA and post hoc Tukey tests. P<0.05 was considered as the limit of significance. "nResults: Dye penetration was observed in all groups. Zonalin and Coltosol had the highest and the lowest dye penetration respectively, with a statistically significant difference (p<0.001. There was no significant difference in dye penetration between IRM, and either Coltosol or Zamherir (p>0.05. "nConclusion: The results of this study showed that using Coltosol as a temporary restorative material can provide a better coronal seal in endodontic treatments

  13. Multiphase flow dynamics 2 thermal and mechanical interactions

    CERN Document Server

    Kolev, Nikolay I

    2007-01-01

    The industrial use of multi-phase systems requires analytical and numerical strategies for predicting their behavior. This book contains theory, methods and practical experience for describing complex transient multi-phase processes. It provides a systematic presentation of the theory and practice of numerical multi-phase fluid dynamics.

  14. Monoblock Obturation Technique for Non-Vital Immature Permanent Maxillary Incisors Using Mineral Trioxide Aggregate: Results from Case Series

    International Nuclear Information System (INIS)

    Iqbal, Z.; Qureshi, A. H.

    2014-01-01

    Ten patients presented with non-vital immature teeth for root canal treatment. In all these cases the pre-operative clinical examination revealed apical periodontitis with a buccal sinus tract of endodontic origin. These cases were treated by a mineral trioxide aggregate (MTA) monoblock obturation technique. Follow-up evaluations were performed at 1 - 2 years after treatment. Eight out of 10 cases were associated with periradicular healing at follow-up evaluation. Mineral trioxide aggregate Monoblock obturation technique appears to be a valid material to obtain periradicular healing in teeth with open apices and necrotic pulps. (author)

  15. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment.

    Science.gov (United States)

    Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella

    2008-11-01

    The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

  16. Frontiers and progress in multiphase flow

    CERN Document Server

    2014-01-01

    This volume presents state-of-the-art of reviews in the field of multiphase flow. In focusses on nonlinear aspects of multiphase flow networks as well as visualization experiments. The first chapter presents nonlinear aspects or deterministic chaos issues in the systems of multi-phase reactors.  The second chapter reviews two-phase flow dynamics in combination with complex network theory. The third chapter discusses evaporation mechanism in the wick of copper heat pipes. The last chapter investigates numerically the flow dynamics and heat and mass transfer in the laminar and turbulent boundary layer on the flat vertical plate.

  17. The solutions to your problems in endodontic retreatment and microsurgery

    Directory of Open Access Journals (Sweden)

    Leslie Ang

    2016-06-01

    How to find the 4th canal in the upper Second molars in 60% of your patients, How to find the 4th canal in the upper First molars in 90% of your patients, How to retreat canals root filled with metal posts, fiber posts, gutta percha, hard canal cement & thermafils, How to remove fractured posts and posts cemented with resin cements. Understand why and how to perform Endodontic Surgery: How to treat large periapical lesions microsurgically, How to use the latest Ultrasonic technology under the Surgical Operating Microscope in all forms of microsurgery, Learn about the modern concepts in transplants, apicoectomies and intentional replantations.

  18. Prevalence of and factors affecting post-obturation pain following single visit root canal treatment in Indian population: A prospective, randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Syed Gufran Ali

    2012-01-01

    Full Text Available Aim: This prospective randomized clinical study (1 investigated the prevalence of post-obturation pain after single visit root canal treatment and (2 evaluated the influence of factors affecting the pain experience. Materials and Methods: One thousand three hundred and twenty eight (1328 patients were included in this study. Conventional single visit root canal treatment was carried out. The chemicomechanical preparation of root canals was done by a rotary protaper system with a combination of hand instruments. Post-operative pain was recorded by each patient by using visual analogue scale in well-defined categories at three time intervals, 12 h, 24 h, and 48 h. The data were analyzed using Fisher′s exact test. Results: The prevalence of post-obturation pain (severe within 48 h after treatment was 4% ( n = 54 but less as compared to the pain experienced after 12 h (9% and 24 h (8.6%. The factors that significantly influenced post-obturation pain experience were: Age (Fishers exact test = 46.387, P = 0.0, gender (Fishers exact test = 23.730, P = 0.0, arch (Fishers exact test = 11.710, P = 0.001, and presence of pre-operative pain (Fishers exact test = 67.456, P = 0.0. Conclusion: The presence of post-operative pain was low (4%. The important prognostic determinants of post-obturation pain were: Old age, female, mandibular teeth, and presence of pre-operative pain. The vital condition of the tooth does not affect the intensity and frequency of post-obturation pain.

  19. Health-related quality of life after maxillectomy: obturator rehabilitation compared with flap reconstruction.

    Science.gov (United States)

    Breeze, J; Rennie, A; Morrison, A; Dawson, D; Tipper, J; Rehman, K; Grew, N; Snee, D; Pigadas, N

    2016-10-01

    Health-related quality of life (QoL) reported by patients has the potential to improve care after ablative surgery of the midface, as existing treatment algorithms still generally revolve around outcomes assessed traditionally only by clinicians. Decisions in particular relate to reconstruction with a flap compared with rehabilitation with an obturator, the need for adjuvant treatment, and morbidity related to the size of the defect. We prospectively collected health-related QoL assessments for 39 consecutive patients treated by maxillectomy between 01 January 2010 and 31 December 2014 using the University of Washington Quality of Life Questionnaire, and who had a mean (SD) duration of follow-up of 14 (4). We made sub-group analyses using paired t tests and analysis of variance (ANOVA) to compare reconstruction with a flap with rehabilitation with obturators, size of the vertical defect, and whether adjuvant treatment with radiotherapy or chemoradiotherapy adversely affected it. Overall there was a significant decrease in health-related QoL after treatment compared with before (p<0.001), but there was no significant difference in the effects of any of the paired reconstructive and rehabilitation treatments on it. Obturators remain an important option for rehabilitation in selected patients in addition to reconstruction with a flap. We found that neither increasing the size of the vertical defect (in an attempt to ensure clear margins) nor the use of postoperative radiotherapy seemed to have any adverse effect on QoL. More patients are required before we can conclude that the potential survival benefits of such measures may outweigh any adverse effects. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Multiphase forces on bend structures – critical gas fraction for transition single phase gas to multiphase flow behaviour

    NARCIS (Netherlands)

    Belfroid, S.P.C.; Nennie, E.D.; Lewis, M.

    2016-01-01

    Piping structures are generally subjected to high dynamic loading due to multiphase forces. In particular subsea structures are very vulnerable as large flexibility is required to cope for instance with thermal stresses. The forces due to multiphase flow are characterized by a broadband spectrum

  1. On multiphase negative flash for ideal solutions

    DEFF Research Database (Denmark)

    Yan, Wei; Stenby, Erling Halfdan

    2012-01-01

    simpler than the corresponding normal flash algorithm. Unlike normal flash, multiphase negative flash for ideal solutions can diverge if the feasible domain for phase amounts is not closed. This can be judged readily during the iteration process. The algorithm can also be extended to the partial negative......There is a recent interest to solve multiphase negative flash problems where the phase amounts can be negative for normal positive feed composition. Solving such a negative flash problem using successive substitution needs an inner loop for phase distribution calculation at constant fugacity...... coefficients. It is shown that this inner loop, named here as multiphase negative flash for ideal solutions, can be solved either by Michelsen's algorithm for multiphase normal flash, or by its variation which uses F−1 phase amounts as independent variables. In either case, the resulting algorithm is actually...

  2. Internal obturator muscle transposition for treatment of perineal hernia in dogs: 34 cases (1998-2012).

    Science.gov (United States)

    Shaughnessy, Magen; Monnet, Eric

    2015-02-01

    To evaluate the outcome of dogs with perineal hernia treated with transposition of the internal obturator muscle. Retrospective case series. 34 dogs. Medical records of dogs with perineal hernia surgically treated from 1998 to 2012 were reviewed. Diagnostic methods and surgical techniques were recorded. Dogs were assigned preoperative and postoperative clinical sign scores. Complication and recurrence rates were evaluated over time. Risk factors were determined. Median follow-up time was 345 days (range, 22 to 1,423 days). Complications were observed in 10 dogs. Tenesmus (n = 9), dyschezia (7), fecal impaction (3), stranguria (4), hematochezia (2), urinary incontinence (2), diarrhea (1), urinary tract infection (1), and megacolon (1) occurred following surgery. Bladder retroflexion at the time of initial evaluation or surgery was not a risk factor for complication (hazard ratio, 1.72). One year after surgery, 51.2% dogs were free of complications. Three dogs developed a perineal hernia on the contralateral side between 35 and 95 days after surgery. The 1-year recurrence rate was 27.4%. Median time for recurrence was 28 days after surgery (range, 2 to 364 days). Postoperative tenesmus was a risk factor for the development of recurrence (hazard ratio, 2.29). Internal obturator muscle transposition was used for primary repair of perineal hernia in dogs. Recurrence was recorded as long as 1 year after surgery. Tenesmus was a risk factor for the development of recurrence after treatment of perineal hernia with internal obturator muscle transposition.

  3. The simulation of multidimensional multiphase flows

    International Nuclear Information System (INIS)

    Lahey, Richard T.

    2005-01-01

    This paper presents an assessment of various models which can be used for the multidimensional simulation of multiphase flows, such as may occur in nuclear reactors. In particular, a model appropriate for the direct numerical simulation (DNS) of multiphase flows and a mechanistically based, three-dimensional, four-field, turbulent, two-fluid computational multiphase fluid dynamics (CMFD) model are discussed. A two-fluid bubbly flow model, which was derived using potential flow theory, can be extended to other flow regimes, but this will normally involve ensemble-averaging the results from direct numerical simulations (DNS) of various flow regimes to provide the detailed numerical data necessary for the development of flow-regime-specific interfacial and wall closure laws

  4. Obturator internus pyomyositis manifested as sciatica in a patient with subacute bacterial endocarditis: A rare case report.

    Science.gov (United States)

    Hsu, Wei-Ching; Hsu, Jin-Yi; Chen, Michael Yu-Chih; Liang, Chung-Chao

    2016-07-01

    Pyomyositis is a pyogenic infection of the skeletal muscles causing myalgia and fever in patients. Hematogenous seeding engendered by persistent bacteremia and septic embolism is usually the underlying cause of the disease. Trauma, intravenous drug use, and immunodeficiency are the main predisposing factors.Obturator internus pyomyositis with sciatica has not previously been reported. We report a rare case of a patient with subacute bacterial endocarditis presenting with left buttock pain and sciatica.Computed tomography confirmed the diagnosis of obturator internus pyomyositis. The patient was discharged uneventfully after successful antibiotic treatment.The mortality rate of patients who have pyomyositis comorbid with another condition or disease is extremely high. Early diagnosis and aggressive management are imperative.

  5. Comparison of radiographic density and compaction index of root canal obturation using nickel titanium or stainless-steel spreaders

    Directory of Open Access Journals (Sweden)

    M. Adel

    2016-08-01

    Full Text Available Background: Both nickel titanium and stainless-steel spreaders are available. The obvious advantage of nickel titanium spreader over stainless steel spreaders is greater penetration in curved canals. Objective: To compare the radiographic density and compaction index of root canal obturation using nickel-titanium or stainless-steel spreaders in curved canals. Methods: In this experimental study the primary weight of 30 acrylic blocks with 45o degrees of apical curvature were measured by a scale (W1. After canals were prepared by step back master apical up to file #30 all blocks were weighed again (W2 and randomly divided in two groups of 15each. All canals were obturated by Cold lateral compaction technique (with nickel-titanium in one group and stainless-steel finger spreaders in another group. After all blocks were reweighed (W3, compaction index (W3-W2/W1-W2 was calculated. One radiograph was taken for each sample. Apical density of the apical third of each canal was measured by digital transmission densitometer. Data were analyzed statistically using T-test. Findings: Mean compaction index for nickel-titanium group was 7.67±2.38 and for stainless-steel group was 9.14±4.06. There was no significant difference between two groups. Mean radiographic density of obturation was 2.05±0.14 in nickel-titanium group and was 2.07±0.21 in stainless-steel group. There was no significant difference between two groups. Conclusion: It is concluded that nickel-titanium spreaders are not superior than stainless-steel spreaders in obturating curved canal.

  6. Advances in multiphase flow and related problems

    International Nuclear Information System (INIS)

    Papanicolaou, G.

    1986-01-01

    Proceedings of a workshop in multiphase flow held at Leesburg, Va. in June 1986 representing a cross-disciplinary approach to theoretical as well as computational problems in multiphase flow. Topics include composites, phase transitions, fluid-particle systems, and bubbly liquids

  7. PWR pressurizer with heaters well which can be obturate and sealing process

    International Nuclear Information System (INIS)

    Godin, B.; Guicherd, L.

    1991-01-01

    Each heater well is prolongated at the end located outer the pressurizer containment by a sleeve internally tapped which is prolongated at the other end by a guiding and fixation sleeve for welding the heater. The heater well can be obturated by a threaded plug introduce in the tapped part of the sleeve after cutting the welding sleeve and extraction of the heater [fr

  8. Methods for compressible multiphase flows and their applications

    Science.gov (United States)

    Kim, H.; Choe, Y.; Kim, H.; Min, D.; Kim, C.

    2018-06-01

    This paper presents an efficient and robust numerical framework to deal with multiphase real-fluid flows and their broad spectrum of engineering applications. A homogeneous mixture model incorporated with a real-fluid equation of state and a phase change model is considered to calculate complex multiphase problems. As robust and accurate numerical methods to handle multiphase shocks and phase interfaces over a wide range of flow speeds, the AUSMPW+_N and RoeM_N schemes with a system preconditioning method are presented. These methods are assessed by extensive validation problems with various types of equation of state and phase change models. Representative realistic multiphase phenomena, including the flow inside a thermal vapor compressor, pressurization in a cryogenic tank, and unsteady cavitating flow around a wedge, are then investigated as application problems. With appropriate physical modeling followed by robust and accurate numerical treatments, compressible multiphase flow physics such as phase changes, shock discontinuities, and their interactions are well captured, confirming the suitability of the proposed numerical framework to wide engineering applications.

  9. Evaluation of apically extruded debris during root canal retreatment with several NiTi systems.

    Science.gov (United States)

    Dincer, A N; Er, O; Canakci, B C

    2015-12-01

    To compare the amount of debris extruded apically during root canal retreatment using ProTaper, Mtwo and Reciproc instruments with hand H-files. In total, 60 freshly extracted human mandibular incisor teeth were used. All root canals were prepared with a Reciproc R25 file than filled with Gutta-percha and AH Plus sealer using cold lateral condensation before being assigned randomly to four groups (n = 15 each). In group 1, root fillings were removed with the Protaper Universal retreatment system; ProTaper Universal F3 and F4 instruments were used for the final preparation. In group 2, root fillings were removed with the Mtwo retreatment system; Mtwo size 30, .06 taper, size 35, .06 taper and size 40, .06 taper files were used for the final preparation. In group 3, root fillings were removed with Reciproc R25 instruments; Reciproc R40 instruments were used for the final preparation. In group 4, the root fillings were removed with Gates Glidden burs and sizes 35, 30 and 25 H-files; for final preparation, a size 40 H-file was used. Glass vials were used for debris collection. The vials were weighed before and after Gutta-percha removal. Additionally, the times required for the retreatment procedures were recorded. Data were analysed statistically using one-way analysis of variance. The Reciproc system produced significantly smaller amounts of apical extruded debris than the other groups (P ProTaper groups. The ProTaper and Reciproc groups required significantly less time than the Mtwo and H-file groups (P hand filing. Use of the ProTaper and Reciproc instruments required less time for retreatment procedures than use of the Mtwo or H-file. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  11. A First Step in De Novo Synthesis of a Living Pulp Tissue Replacement Using Dental Pulp MSCs and Tissue Growth Factors, Encapsulated within a Bioinspired Alginate Hydrogel.

    Science.gov (United States)

    Bhoj, Manasi; Zhang, Chengfei; Green, David W

    2015-07-01

    A living, self-supporting pulp tissue replacement in vitro and for transplantation is an attractive yet unmet bioengineering challenge. Our aim is to create 3-dimensional alginate-based microenvironments that replicate the shape of gutta-percha and comprise key elements for the proliferation of progenitor cells and the release of growth factors. An RGD-bearing alginate framework was used to encapsulate dental pulp stem cells and human umbilical vein endothelial cells in a ratio of 1:1. The alginate hydrogel also retained and delivered 2 key growth factors, vascular endothelial growth factor-121 and fibroblast growth factor, in a sufficient amount to induce proliferation. A method was then devised to replicate the shape of gutta-percha using RGD alginate within a custom-made mold of thermoresponsive N-isopropylacrylamide. Plugs of alginate containing different permutations of growth factor-based encapsulates were tested and evaluated for viability, proliferation, and release kinetics between 1 and 14 days. According to scanning electron microscopic and confocal microscopic observations, the encapsulated human endothelial cells and dental pulp stem cell distribution were frequent and extensive throughout the length of the construct. There were also high levels of viability in all test environments. Furthermore, cell proliferation was higher in the growth factor-based groups. Growth factor release kinetics also showed significant differences between them. Interestingly, the combination of vascular endothelial growth factor and fibroblast growth factor synergize to significantly up-regulate cell proliferation. RGD-alginate scaffolds can be fabricated into shapes to fill the pulp space by simple templating. The addition of dual growth factors to cocultures of stem cells within RGD-alginate scaffolds led to the creation of microenvironments that significantly enhance the proliferation of dental pulp stem cell/human umbilical vein endothelial cell combinations. Copyright

  12. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  13. Objective clinical assessment of change in swallowing ability of maxillectomy patients when wearing obturator prostheses.

    Science.gov (United States)

    Matsuyama, Miwa; Tsukiyama, Yoshihiro; Koyano, Kiyoshi

    2005-01-01

    Evaluation of treatment outcome is important in maxillofacial rehabilitation. Although eating is one of the oral functions that most strongly influences patients' quality of life, only a few reports exist on the objective assessment of swallowing for maxillectomy patients. The purpose of this study was to identify changes in the swallowing ability of maxillectomy patients when wearing obturator prostheses through the use of an objective clinical assessment. The swallowing ability of 38 postmaxillectomy patients consecutively treated with obturator prostheses was objectively evaluated with the "water-drinking test" that was developed for the assessment of dysphagia patients after cerebrovascular disease. In this test, the subjects were instructed to drink 30 mL of water in one swallow. The profile was evaluated with the combination of the time required for drinking the water and the incidence of cough reflex. Statistical analysis was performed using the Wilcoxon signed-rank test, the paired t test, and the Chi-square test with StatView 5.0 for the Macintosh. Performance improved significantly when the patients wore prostheses (P = .0026, Wilcoxon signed-rank test). The mean drinking times without and with prostheses were 8.2 +/- 6.3 s and 5.0 +/- 3.5 s, respectively. Drinking time was shortened significantly when the prosthesis was worn (P = .0002, paired t test). The assessment of behavior and episodes revealed that the swallowing ability of the maxillectomy patients was significantly improved when a prosthesis was worn (P = .0002, Chi-square test). The swallowing ability of maxillectomy patients was quantitatively and qualitatively improved with obturator prostheses.

  14. International Symposium of Cavitation and Multiphase Flow (ISCM 2014)

    International Nuclear Information System (INIS)

    Wu, Yulin

    2015-01-01

    The International Symposium on Cavitation and Multiphase Flow (ISCM 2014) was held in Beijing, China during 18th-21st October, 2014, which was jointly organized by Tsinghua University, Beijing, China and Jiangsu University, Zhenjiang, China. The co-organizer was the State Key Laboratory of Hydroscience and Engineering, Beijing, China. Cavitation and multiphase flow is one of paramount topics of fluid mechanics with many engineering applications covering a broad range of topics, e.g. hydraulic machinery, biomedical engineering, chemical and process industry. In order to improve the performances of engineering facilities (e.g. hydraulic turbines) and to accelerate the development of techniques for medical treatment of serious diseases (e.g. tumors), it is essential to improve our understanding of cavitation and Multiphase Flow. For example, the present development towards the advanced hydrodynamic systems (e.g. space engine, propeller, hydraulic machinery system) often requires that the systems run under cavitating conditions and the risk of cavitation erosion needs to be controlled. The purpose of the ISCM 2014 was to discuss the state-of-the-art cavitation and multiphase flow research and their up-to-date applications, and to foster discussion and exchange of knowledge, and to provide an opportunity for the researchers, engineers and graduate students to report their latest outputs in these fields. Furthermore, the participants were also encouraged to present their work in progress with short lead time and discuss the encountered problems. ISCM 2014 covers all aspects of cavitation and Multiphase Flow, e.g. both fundamental and applied research with a focus on physical insights, numerical modelling and applications in engineering. Some specific topics are: Cavitating and Multiphase Flow in hydroturbines, pumps, propellers etc. Numerical simulation techniques Cavitation and multiphase flow erosion and anti-erosion techniques Measurement techniques for cavitation and

  15. Technical Report on NETL's Non Newtonian Multiphase Slurry Workshop: A path forward to understanding non-Newtonian multiphase slurry flows

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Chris [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Garg, Rahul [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2013-08-19

    The Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) sponsored a workshop on non-Newtonian multiphase slurry at NETL’s Morgantown campus August 19 and 20, 2013. The objective of this special two-day meeting of 20-30 invited experts from industry, National Labs and academia was to identify and address technical issues associated with handling non-Newtonian multiphase slurries across various facilities managed by DOE. Particular emphasis during this workshop was placed on applications managed by the Office of Environmental Management (EM). The workshop was preceded by two webinars wherein personnel from ORP and NETL provided background information on the Hanford WTP project and discussed the critical design challenges facing this project. In non-Newtonian fluids, viscosity is not constant and exhibits a complex dependence on applied shear stress or deformation. Many applications under EM’s tank farm mission involve non-Newtonian slurries that are multiphase in nature; tank farm storage and handling, slurry transport, and mixing all involve multiphase flow dynamics, which require an improved understanding of the mechanisms responsible for rheological changes in non-Newtonian multiphase slurries (NNMS). To discuss the issues in predicting the behavior of NNMS, the workshop focused on two topic areas: (1) State-of-the-art in non-Newtonian Multiphase Slurry Flow, and (2) Scaling up with Confidence and Ensuring Safe and Reliable Long-Term Operation.

  16. Radix Entomolaris: A Case Report

    Directory of Open Access Journals (Sweden)

    Movassagh

    2016-05-01

    Full Text Available Introduction During endodontic treatment the variety of mandibular sectorial in the form of an extra lingual (radix entomolaris or buccal root (radix paramolaris can often cause difficulties. In other words, awareness and understanding of this unusual root, and its canal morphology, are factors that can affect the outcome of root canal treatment. Case Presentation A 30-year-old male patient with a history of severe, throbbing, constant pain in the lower mandibular molars was referred to the department of endodontics of Hamedan Dental university. The patient’s medical history was noncontributory. The buccal object rule (same-lingual opposite-buccal technique confirmed the additional root as a distolingual root (radix entomolaris. Following the evaluation of vitality tests, we began endodontic treatment for this patient, after administration of local anesthesia using 2% lidocaine with 1:80,000 epinephrine (Daroupakhsh, Tehran, Iran and rubber dam isolation. The working length was determined by a Root ZX apex locator (Dentaport ZX, J Morita and later confirmed by parallel periapical radiograph. Canals were shaped in a crown down fashion with Protaper Nickel Titanium rotary instruments (Dentsply, Maillefer under copious irrigation with 2.5% sodium hypochlorite and lubrication with RC-Prep. After drying the canals with paper points, the master gutta-percha points were fitted within the canals and confirmation radiography was taken. The root canal system was obturated with the cold lateral compaction technique. Conclusions This case is about a mandibular molar with radix entomolaris and the radiographic exploration and endodontic order. Clinicians should be aware of these unusual root morphologies in the mandibular molars. The initial diagnosis of a radix entomolaris or paramolaris before root canal treatment is important to facilitate the endodontic procedure.

  17. The Use of a Novel Approach for the Instrumentation of a Cone-beam Computed Tomography-discernible Lateral Canal in an Unusual Maxillary Incisor: Case Report.

    Science.gov (United States)

    Chaniotis, Antonis; Filippatos, Christos G

    2017-06-01

    Lateral and apical ramifications of the main root canal create potential pathways through which bacteria can spread and remain unaffected by treatment procedures. It is a challenge for the specialty to find techniques that can predictably reach, disinfect, and obturate these ramifications. Here, we report the use of a novel instrumentation approach to aid in the negotiation and management of a lateral canal discernible on cone-beam computed tomography (CBCT) in an unusual maxillary central incisor. A 23-year-old female patient was referred for evaluation and possible treatment of tooth 9. The periapical radiographic examination revealed pulp chamber obliteration, existence of a lateral lesion, and a possible complex internal root canal anatomy. The CBCT evaluation revealed the existence of a lateral lesion, a periapical lesion, an additional distopalatal canal, and a lateral canal exiting at the lateral lesion. The diagnosis of asymptomatic apical and lateral periodontitis of tooth 9 was reached. CBCT-aided access cavity preparation and scouting resulted in the successful negotiation of all canals, main and lateral. A novel instrumentation technique with precurved controlled memory files was used for the mechanical preparation of the lateral canal to a 25/04 enlargement. Obturaton of the lateral canal was achieved with a single gutta-percha cone and AH Plus Root Canal Sealer. At the 2-year follow-up, the patient was asymptomatic, and the 2-dimensional radiographic examinations revealed resolution of both the periapical and the lateral lesions. This case report describes the application of a novel instrumentation technique for the mechanical debridement of an infected lateral canal discernible on CBCT and reinforces the importance of treating the root canals as systems that possesses anatomic intricacies that need to be addressed. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Antibiotic Use in 2016 by Members of the American Association of Endodontists: Report of a National Survey.

    Science.gov (United States)

    Germack, Mark; Sedgley, Christine M; Sabbah, Wael; Whitten, Brian

    2017-10-01

    This study surveyed the antibiotic prescribing practices of endodontists, and data were compared with previous surveys conducted in 1994 and 1999. A 17-question survey was sent via www.surveymonkey.com to 3000 active members of the American Association of Endodontists for responses about antibiotic prescribing practices and demographics. The data were analyzed using descriptive statistics, chi-square tests, and linear regression analyses. Six hundred eighty-six participants (22.86%) completed the survey. The most frequently prescribed antibiotics were amoxicillin (60.71%) followed by penicillin V (30.43%) and clindamycin for patients with allergies (95.4%). Respondents reported prescribing antibiotics for irreversible pulpitis with mild symptoms (1.75%), irreversible pulpitis with moderate symptoms (6.41%), necrotic pulp with symptomatic apical periodontitis (43.59%), chronic apical abscess without (10.50%) or with symptoms (29.74%), acute apical abscess (95.92%), avulsion (70.26%), endodontic surgery (41.69%), retreatment (silver point [23.76%] or gutta-percha [15.60%]), postoperative pain after instrumentation or obturation (12.39%), and perforation repair (5.98%). The type of practice (solo/group) and geographic region (Southeast) were significant predictors of increased antibiotic prescribing; 36.89% of respondents reported prescribing antibiotics that are not necessary, most commonly because of patient expectations. Since 1999, there has been a significant shift from prescribing penicillin V to amoxicillin as endodontists' first choice of antibiotic and a significant increase in the use of clindamycin for penicillin-allergic patients. Antibiotics continue to be prescribed in clinical situations for which they are typically not indicated, most commonly because of patient expectations. Regional differences in antibiotic prescribing practices by endodontists exist in the United States. Copyright © 2017 American Association of Endodontists. Published by Elsevier

  19. Effect of calcium hydroxide and double and triple antibiotic pastes on the bond strength of epoxy resin-based sealer to root canal dentin.

    Science.gov (United States)

    Akcay, Merve; Arslan, Hakan; Topcuoglu, Hüseyin Sinan; Tuncay, Oznur

    2014-10-01

    The aim of this study was to evaluate the effects of calcium hydroxide (CH) and triple (TAP) and double (DAP) antibiotic pastes on the bond strength of an epoxy resin-based sealer (AH Plus Jet; Dentsply DeTrey, Konstanz, Germany) to the root canal dentin. Sixty-four single-rooted human mandibular premolars were decoronated and prepared using the rotary system to size 40. The specimens were randomly divided into a control group (without intracanal dressing) and 3 experimental groups that received an intracanal dressing with either CH, DAP, or TAP (n = 16). The intracanal dressing was removed by rinsing with 10 mL 17% EDTA followed by 10 mL 2.5% sodium hypochlorite. The root canals were then obturated with gutta-percha and AH Plus Jet sealer. A push-out test was used to measure the bond strength between the root canal dentin and the sealer. The data were analyzed using 2-way analysis of variance and Tukey post hoc tests to detect the effect of the independent variables (intracanal medicaments and root canal thirds) and their interactions on the push-out bond strength of the root canal filling material to the root dentin (P = .05). The push-out bond strength values were significantly affected by the intracanal medicaments (P .05). In the middle and apical third, the bond strength of the TAP group was higher than those of the CH and DAP groups (P < .05). The DAP and CH did not affect the bond strength of the epoxy resin-based sealer. Additionally, the TAP improved the bond strength of the epoxy resin-based sealer in the middle and apical thirds. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Effect of Endodontic Retreatment on Push-out Bond Strength and Quality of Fiber Postbonding Interface of Resin Cements.

    Science.gov (United States)

    Pelegrine, Rina Andréa; Paulillo, Luís Alexandre Maffei Sartini; Kato, Augusto Shoji; Fontana, Carlos Eduardo; Pinheiro, Sérgio Luiz; De Martin, Alexandre Sigrist; Bueno, Carlos Eduardo da Silveira

    2016-01-01

    The aim of this study is to evaluate the impact of endodontic retreatment on push-out bond strength and dentin interface of two resin cements used for fiber postcementation during endodontic retreatment. The root canals of 40 extracted human canines were prepared, obturated and divided into four groups (n = 10). Gutta-percha was partially removed and fiber posts were immediately cemented in groups 1 and 2 using Panavia F with ED Primer and RelyX™ U200, respectively. In groups 3 and 4, the root canal access was sealed with temporary restorative cement, specimens were stored for 30 days, endodontically retreated, and fiber posts were cemented using the resin cements applied to groups 1 and 2, respectively. Push-out tests and scanning electron microscopy analyses of different areas were performed. Data from push-out bond strengths were analyzed by one-way analysis of variance and Tukey's tests. Higher bond strength values were detected in the apical third for group 1 than group 3 (p 0.05). Comparisons between different thirds in the same group revealed a higher bond strength in the apical third for group 1. Scanning electron microscopy showed formation of hybrid layer and extensive resin tags in group 1. No hybrid layer was observed in groups 2 and 4. Endodontic retreatment had adverse effects on the push-out bond strength and dentinal interface of Panavia F with ED Primer when used for fiber postcementation specifically in the apical third, but not on RelyX™ U200. A significant interaction was detected between endodontic retreatment and resin cement, which indicated that endodontic retreatment might adversely affect the push-out bond strength and dentinal interface of Panavia F with ED Primer when used for fiber postcementation specifically in the apical third.

  1. Prosthetic rehabilitation of the dentate maxillectomy patient from a delayed surgical to an interim obturator: A clinical case report

    Directory of Open Access Journals (Sweden)

    Angleena Y Daniel

    2015-01-01

    Full Text Available The surgical management of maxillary pathosis results in direct communication between the oral and nasal cavity, imposing problems such as nasal regurgitation, unintelligent speech, difficulty in deglutition and compromised esthetics. A restoration of these defects is not always possible surgically, but prosthetic rehabilitation is an established treatment modality. Early rehabilitation can improve the quality of life and reduce the psychological trauma caused by surgical excision. Surgical and interim obturators placed during the initial phase can improve the outcome of the definitive prosthesis. This article presents a case report of a patient with partial maxillectomy who has been rehabilitated with a delayed surgical and an interim obturator.

  2. Removal of root filling materials.

    LENUS (Irish Health Repository)

    Duncan, H.F. Chong, B.S.

    2011-05-01

    Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.

  3. Root canal obturation of primary teeth: Disposable injection technique

    Directory of Open Access Journals (Sweden)

    S K Bhandari

    2012-01-01

    Full Text Available The aim of the study was to outline a simple, cost-effective technique for obturation of primary tooth root canals. A total of 75 primary teeth were treated in 52 subjects by the technique discussed, i.e. injecting plastic flowable material into the root canals after desired preparation, using disposable needle and syringe. All the patients were followed up for 3 years and 6 months, with no clinical or radiologic evidence of pathology or need for untimely extraction. In conclusion, the technique described is simple, economical, can be used with almost all filling materials used for the purpose, and is easy to master with minimal chances of failure.

  4. Strangulated obturator hernia - an unusual presentation of intestinal obstruction.

    LENUS (Irish Health Repository)

    Zeeshan, Saqib

    2012-01-31

    An 81-year-old Caucasian emaciated female presented with 3 days history of colicky abdominal pain nausea, projectile vomiting and abdominal distension. A pre-operative diagnosis of mechanical bowel obstruction was made. The absence of characteristic clinical signs in this thin elderly woman with a small bowel obstruction failed to provide a pre-operative diagnosis. She underwent a midline laparotomy and resection and anastomosis of small bowel and repair of the strangulated right obturator hernia. The high mortality rate associated with this type of abdominal hernias requires a high index of suspicion to facilitate rapid diagnosis and prompt surgical intervention if the survival rate is to be improved.

  5. Multiphase reacting flows modelling and simulation

    CERN Document Server

    Marchisio, Daniele L

    2007-01-01

    The papers in this book describe the most widely applicable modeling approaches and are organized in six groups covering from fundamentals to relevant applications. In the first part, some fundamentals of multiphase turbulent reacting flows are covered. In particular the introduction focuses on basic notions of turbulence theory in single-phase and multi-phase systems as well as on the interaction between turbulence and chemistry. In the second part, models for the physical and chemical processes involved are discussed. Among other things, particular emphasis is given to turbulence modeling strategies for multiphase flows based on the kinetic theory for granular flows. Next, the different numerical methods based on Lagrangian and/or Eulerian schemes are presented. In particular the most popular numerical approaches of computational fluid dynamics codes are described (i.e., Direct Numerical Simulation, Large Eddy Simulation, and Reynolds-Averaged Navier-Stokes approach). The book will cover particle-based meth...

  6. Industrial applications of multi-functional, multi-phase reactors

    NARCIS (Netherlands)

    Harmsen, G.J.; Chewter, L.A.

    1999-01-01

    To reveal trends in the design and operation of multi-functional, multi-phase reactors, this paper describes, in historical sequence, three industrial applications of multi-functional, multi-phase reactors developed and operated by Shell Chemicals during the last five decades. For each case, we

  7. Cone Beam Computed Tomography Evaluation of the Periapical Status of Nonvital Tooth with Open Apex Obturated with Mineral Trioxide Aggregate: A Case Report

    Directory of Open Access Journals (Sweden)

    Vijay Shekhar

    2013-01-01

    Full Text Available Management of a tooth with open apex is a challenge to the dental practitioners. Evaluation of the periapical healing is required in such cases by radiographic techniques. The objective of this paper was to assess the healing of a periapical lesion in a non-vital tooth with open apex treated with mineral trioxide aggregate (MTA obturation using cone beam computed tomography (CBCT. The endodontic treatment of a fractured non-vital discolored maxillary left lateral incisor with an open apex was done with MTA obturation. The clinical and radiographic followup done regularly showed that the tooth was clinically asymptomatic and that the size of the periapical lesion observed by intraoral periapical (IOPA radiographs and CBCT was decreased remarkably after two years. CBCT and IOPA radiographs were found to be useful radiographic tools to assess the healing of a large periapical lesion in a non-vital tooth with open apex managed by MTA obturation.

  8. Multiphase flow in wells and pipelines

    International Nuclear Information System (INIS)

    Sharma, M.P.; Rohatgi, U.S.

    1992-01-01

    This conference focuses primarily on multi-phase flow modeling and calculation methods for oil and gas although two papers focus more on the fluid mechanics of fluidized beds. Papers include theoretical, numerical modeling, experimental investigation, and state-of-the-art review aspects of multiphase flow. The theme of the symposium being general, the papers reflect generality of gas-liquid, liquid-solid, and gas solid flows. One paper deals with nuclear reactor safety as it relates to fluid flow through the reactor

  9. FOREWORD: International Symposium of Cavitation and Multiphase Flow (ISCM 2014)

    Science.gov (United States)

    Wu, Yulin

    2015-01-01

    The International Symposium on Cavitation and Multiphase Flow (ISCM 2014) was held in Beijing, China during 18th-21st October, 2014, which was jointly organized by Tsinghua University, Beijing, China and Jiangsu University, Zhenjiang, China. The co-organizer was the State Key Laboratory of Hydroscience and Engineering, Beijing, China. Cavitation and multiphase flow is one of paramount topics of fluid mechanics with many engineering applications covering a broad range of topics, e.g. hydraulic machinery, biomedical engineering, chemical and process industry. In order to improve the performances of engineering facilities (e.g. hydraulic turbines) and to accelerate the development of techniques for medical treatment of serious diseases (e.g. tumors), it is essential to improve our understanding of cavitation and Multiphase Flow. For example, the present development towards the advanced hydrodynamic systems (e.g. space engine, propeller, hydraulic machinery system) often requires that the systems run under cavitating conditions and the risk of cavitation erosion needs to be controlled. The purpose of the ISCM 2014 was to discuss the state-of-the-art cavitation and multiphase flow research and their up-to-date applications, and to foster discussion and exchange of knowledge, and to provide an opportunity for the researchers, engineers and graduate students to report their latest outputs in these fields. Furthermore, the participants were also encouraged to present their work in progress with short lead time and discuss the encountered problems. ISCM 2014 covers all aspects of cavitation and Multiphase Flow, e.g. both fundamental and applied research with a focus on physical insights, numerical modelling and applications in engineering. Some specific topics are: Cavitating and Multiphase Flow in hydroturbines, pumps, propellers etc. Numerical simulation techniques Cavitation and multiphase flow erosion and anti-erosion techniques Measurement techniques for cavitation and

  10. Multiphase flow and transport in porous media

    Science.gov (United States)

    Parker, J. C.

    1989-08-01

    Multiphase flow and transport of compositionally complex fluids in geologic media is of importance in a number of applied problems which have major social and economic effects. In petroleum reservoir engineering, efficient recovery of energy reserves is the principal goal. Unfortunately, some of these hydrocarbons and other organic chemicals often find their way unwanted into the soils and groundwater supplies. Removal in the latter case is predicated on ensuring the public health and safety. In this paper, principles of modeling fluid flow in systems containing up to three fluid phases (namely, water, air, and organic liquid) are described. Solution of the governing equations for multiphase flow requires knowledge of functional relationships between fluid pressures, saturations, and permeabilities which may be formulated on the basis of conceptual models of fluid-porous media interactions. Mechanisms of transport in multicomponent multiphase systems in which species may partition between phases are also described, and the governing equations are presented for the case in which local phase equilibrium may be assumed. A number of hypothetical numerical problems are presented to illustrate the physical behavior of systems in which multiphase flow and transport arise.

  11. System for sampling liquids in small jugs obturated by screwed taps

    International Nuclear Information System (INIS)

    Besnier, J.

    1995-01-01

    This invention describes a machine which samples automatically liquids in small jugs obturated by screwed taps. This device can be situated in an isolated room in order to work with radioactive liquids. The machine can be divided in three main parts: a module to catch the jug, in order to take and fix it, a module to open and to close it, and a module to sample. The later takes the liquid thanks to a suction device and puts it in a container, in order to analyse the sample. (TEC)

  12. Multiphase Flow and Fluidization Continuum and Kinetic Theory Descriptions

    CERN Document Server

    Gidaspow, Dimitri

    1994-01-01

    Useful as a reference for engineers in industry and as an advanced level text for graduate engineering students, Multiphase Flow and Fluidization takes the reader beyond the theoretical to demonstrate how multiphase flow equations can be used to provide applied, practical, predictive solutions to industrial fluidization problems. Written to help advance progress in the emerging science of multiphase flow, this book begins with the development of the conservation laws and moves on through kinetic theory, clarifying many physical concepts (such as particulate viscosity and solids pressure) and i

  13. A Multiphase Model for the Intracluster Medium

    Science.gov (United States)

    Nagai, Daisuke; Sulkanen, Martin E.; Evrard, August E.

    1999-01-01

    Constraints on the clustered mass density of the universe derived from the observed population mean intracluster gas fraction of x-ray clusters may be biased by reliance on a single-phase assumption for the thermodynamic structure of the intracluster medium (ICM). We propose a descriptive model for multiphase structure in which a spherically symmetric ICM contains isobaric density perturbations with a radially dependent variance. Fixing the x-ray emission and emission weighted temperature, we explore two independently observable signatures of the model in the parameter space. For bremsstrahlung dominated emission, the central Sunyaev-Zel'dovich (SZ) decrement in the multiphase case is increased over the single-phase case and multiphase x-ray spectra in the range 0.1-20 keV are flatter in the continuum and exhibit stronger low energy emission lines than their single-phase counterpart. We quantify these effects for a fiducial 10e8 K cluster and demonstrate how the combination of SZ and x-ray spectroscopy can be used to identify a preferred location in the plane of the model parameter space. From these parameters the correct value of mean intracluster gas fraction in the multiphase model results, allowing an unbiased estimate of clustered mass density to he recovered.

  14. Penetrating Obturator Artery Injury after Gunshot Wounds: A Successful Multidisciplinary Trauma Team Approach to a Potentially Lethal Injury.

    Science.gov (United States)

    Maraqa, Tareq I; Shin, Ji-Sun J; Diallo, Ismael; Sachwani-Daswani, Gul R; Mercer, Leo C

    2017-11-17

    Obturator artery injury (OAI) from pelvic gunshot wounds (GSW) is a rarely reported condition. Hemorrhages from pelvic trauma (PT) are mostly venous. Arterial hemorrhages represent about 10-20% of PTs. When arterial hemorrhages from PT occur, they are a severe and deadly complication often causing significant hemodynamic instability and eventual shock. A  23-year-old male presented to our emergency service via a private vehicle with multiple gunshot wounds to both thighs and to the lower back, resulted in rectal and obturator artery (OA) injuries. The patient underwent a successful coil-embolization of the right OA. Given the density of structures within the pelvis, patients who sustain gunshot wounds to the pelvic region are at high risk for injury to the small bowel, sigmoid colon, rectum, bladder, and/or vascular structures. While bleeding is the major cause of early mortality in PT, rectal injuries carry the highest mortality due to visceral injuries. A high clinical index of suspicion is needed to diagnose an iliac artery injury or injury to its branches. Prompt computed tomographic angiogram (CTA) and embolization of the OA is the best method to control and stop the bleeding and improve the mortality outcome. Clinicians caring for patients presenting with pelvic gunshot wounds should pay attention to the delayed presentation of internal hemorrhage from the OAs. A multidisciplinary team approach is crucial in the successful management of penetrating injuries to the obturator artery.

  15. Evaluation of the muscle morphology of the obturator externus and piriformis as the predictors of avascular necrosis of the femoral head in acetabular fractures.

    Science.gov (United States)

    Maini, Lalit; Kumar, Santosh; Batra, Sahil; Gupta, Rajat; Arora, Sumit

    2016-08-01

    Avascular necrosis (AVN) of femoral head is a recognised complication of fracture dislocation of the hip joint but is not studied frequently in relation to acetabulum fractures. The aim was to establish the relationship between obturator externus and piriformis muscle morphology in acetabulum fractures and potenital development of AVN of the femoral head. Twenty-five fractures were included in this prospective study and were subjected to radiological assessment and computed tomography of the pelvis. Magnetic resonance imaging (MRI) of the hip was performed to assess the morphology of obturator externus and piriformis, and findings were compared intraoperatively (in 15 cases). Serial radiographs were taken at monthly intervals to assess the development of avascular necrosis. The patients with no evidence of AVN on radiographs at 6 months had additional MRI scans to look for such changes. Three patients developed AVN of femoral head and two had complete tears of piriformis and/or obturator externus muscles on the pre-operative MRI with the findings confirmed intraoperatively (p = 0.013). None of the patients without changes of AVN at 6-month follow-up had complete tears of either or both muscles. Of these patients, there was one case each of T-type fracture, isolated posterior wall fracture with hip dislocation, and posterior wall with transverse fracture of the acetabulum. Complete tears of obturator externus and/or piriformis muscles are a strong predictor of future development of AVN of the femoral head.

  16. 2nd International Conference on Multiphase Flow - ICMF '95

    CERN Document Server

    Fukano, T; Bataille, Jean

    1995-01-01

    There is increasing world-wide interest in obtaining an understanding of various multiphase flow phenomena and problems in terms of a common language of multiphase flow. This volume contains state-of-the-art papers which have been contributed from all over the world by experts working on all aspects of multiphase flows. The volume also highlights international technology-sharing in the fields of energy, environment and public health, in order to create a brighter and sustainable future for man and for all life in the next century. It is intended that this volume will serve as a major source of

  17. High-temperature multiphase flowmeters in heavy-oil thermal production

    Energy Technology Data Exchange (ETDEWEB)

    Mehdizadeh, P. [Society of Petroleum Engineers, Richardson, TX (United States)]|[Production Technology Inc. (United States)

    2005-11-01

    A review of field tests assessing the capability and advantages of multi-phase metering technology in high temperature thermal recovery processes such as cyclic steam stimulation (CSS) and steam assisted gravity drainage (SAGD) was presented. A number of different tank gauging procedures were conducted to obtain a reference flow rate. Subsequent performance tests of metered data and tank data verified the accuracy of the meter, and that water cut sampling can be attained under practical field conditions. A 12 well field test was then conducted, and an allocation factor was obtained from conventional test separators and production measurements. An improvement in the allocation factor was noted. However, a full evaluation of the multiphase meter data obtained in the field was limited by the quality of the reference field data. A 30 day well testing campaign showed a comparison of well rate data from the multi-phase meter with data from an emulsion meter. It was concluded that the multiphase meter provided consistent measurements, matching the level of accuracy attained from rigorous tank measurements. In addition, the multiphase meter eliminated the need for the equipment modifications and extra personnel interventions needed to perform tank testing and manual and automatic water cut sampling. 15 refs., 2 tabs., 6 figs.

  18. A Senior Project-Based Multiphase Motor Drive System Development

    Science.gov (United States)

    Abdel-Khalik, Ayman S.; Massoud, Ahmed M.; Ahmed, Shehab

    2016-01-01

    Adjustable-speed drives based on multiphase motors are of significant interest for safety-critical applications that necessitate wide fault-tolerant capabilities and high system reliability. Although multiphase machines are based on the same conceptual theory as three-phase machines, most undergraduate electrical machines and electric drives…

  19. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    Directory of Open Access Journals (Sweden)

    Georgios Kouveliotis

    2017-01-01

    Full Text Available Introduction: Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case: A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heatcured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion: Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  20. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  1. Fundamentals of Turbulent and Multi-Phase Combustion

    CERN Document Server

    Kuo, Kenneth Kuan-yun

    2012-01-01

    Detailed coverage of advanced combustion topics from the author of Principles of Combustion, Second Edition Turbulence, turbulent combustion, and multiphase reacting flows have become major research topics in recent decades due to their application across diverse fields, including energy, environment, propulsion, transportation, industrial safety, and nanotechnology. Most of the knowledge accumulated from this research has never been published in book form-until now. Fundamentals of Turbulent and Multiphase Combustion presents up-to-date, integrated coverage of the fundamentals of turbulence

  2. Multiphase anodic layers and prospects of their application

    International Nuclear Information System (INIS)

    Rudnev, V.S.

    2008-01-01

    Data on the phase composition of multiphase layers prepared on valve metals (aluminium, titanium, and their alloys) by the plasma-electrochemical oxidation and deposition (PEOD) from aqueous electrolytes containing iso- and heteropolyoxoanions, polyphosphate and fluoride metal complexes (M=Eu, Y, Hf, Nb, Zr, W), as well as electrolytes evolving solid precipitates, is summarized. Possible application fields of the metal/multiphase PEOD surface structure compositions are considered [ru

  3. Hysteresis in multiphase microfluidics at a T-junction.

    Science.gov (United States)

    Zagnoni, Michele; Anderson, Jamie; Cooper, Jonathan M

    2010-06-15

    Multiphase microfluidics offer a wide range of functionalities in the fields of fluid dynamics, biology, particle synthesis, and, more recently, also in logical computation. In this article, we describe the hysteresis of immiscible, multiphase flow obtained in hydrophilic, microfluidic systems at a T-junction. Stable and unstable state behaviors, in the form of segmented and parallel flow patterns of oil and water, were reliably produced, depending upon the history of the flow rates applied to the phases. The transition mechanisms between the two states were analyzed both experimentally and using numerical simulations, describing how the physical and fluid dynamic parameters influenced the hysteretic behavior of the flow. The characteristics of these multiphase systems render them suitable to be used as pressure comparators and also for the implementation of microfluidic logic operations.

  4. On modeling of structured multiphase mixtures

    International Nuclear Information System (INIS)

    Dobran, F.

    1987-01-01

    The usual modeling of multiphase mixtures involves a set of conservation and balance equations of mass, momentum, energy and entropy (the basic set) constructed by an averaging procedure or postulated. The averaged models are constructed by averaging, over space or time segments, the local macroscopic field equations of each phase, whereas the postulated models are usually motivated by the single phase multicomponent mixture models. In both situations, the resulting equations yield superimposed continua models and are closed by the constitutive equations which place restrictions on the possible material response during the motion and phase change. In modeling the structured multiphase mixtures, the modeling of intrinsic motion of grains or particles is accomplished by adjoining to the basic set of field equations the additional balance equations, thereby placing restrictions on the motion of phases only within the imposed extrinsic and intrinsic sources. The use of the additional balance equations has been primarily advocated in the postulatory theories of multiphase mixtures and are usually derived through very special assumptions of the material deformation. Nevertheless, the resulting mixture models can predict a wide variety of complex phenomena such as the Mohr-Coulomb yield criterion in granular media, Rayleigh bubble equation, wave dispersion and dilatancy. Fundamental to the construction of structured models of multiphase mixtures are the problems pertaining to the existence and number of additional balance equations to model the structural characteristics of a mixture. Utilizing a volume averaging procedure it is possible not only to derive the basic set of field equation discussed above, but also a very general set of additional balance equations for modeling of structural properties of the mixture

  5. Numerical simulation of complex multi-phase fluid of casting process and its applications

    Directory of Open Access Journals (Sweden)

    CHEN Li-liang

    2006-05-01

    Full Text Available The fluid of casting process is a typical kind of multi-phase flow. Actually, many casting phenomena have close relationship with the multi-phase flow, such as molten metal filling process, air entrapment, slag movement, venting process of die casting, gas escaping of lost foam casting and so on. Obviously, in order to analyze these phenomena accurately, numerical simulation of the multi-phase fluid is necessary. Unfortunately, so far, most of the commercial casting simulation systems do not have the ability of multi-phase flow modeling due to the difficulty in the multi-phase flow calculation. In the paper, Finite Different Method (FDM technique was adopt to solve the multi-phase fluid model. And a simple object of the muiti-phase fluid was analyzed to obtain the fluid rates of the liquid phase and the entrapped air phase.

  6. Análise anátomo-radiográfica da persistência do Forame de Huschke Anatomic and radiograph study of the persistence of Foramen of Huschke

    Directory of Open Access Journals (Sweden)

    Rodrigo Costa Moreno

    2005-10-01

    Full Text Available OBJETIVO: o objetivo neste trabalho é avaliar e localizar o Forame de Huschke. FORMA DE ESTUDO: anatômico. MATERIAL E MÉTODO: utilizando materiais de contraste como a Guta percha e o sulfato de bário, através de técnicas radiográficas extrabucais, como a panorâmica, submentovértex e a tomografia linear lateral corrigida para a Articulação Têmporo-mandibular, em quatro crânios, onde foi verificada clinicamente a presença do Forame de Huschke. RESULTADO: Os resultados obtidos mostraram que o Forame de Huschke pôde ser observado em crânios secos após a sua evidenciação por meio de material de contraste nestas técnicas radiográficas.AIM: the aim of this study is to assess and locate the Foramen of Huschke. STUDY DESIGN: anatomical. MATERIAL AND METHOD: using contrast material like gutta-percha and barium sulfate, through extraoral radiographs, such as panoramic, submental vertex and corrected saggital linear Temporal Mandibular Joint tomograms in four skulls where we clinically checked the existence of foramen of Huschke. RESULTS: The results proved that the foramen of Huschke can be observed in skulls submitted to contrast using radiographic techniques.

  7. A Transformerless Medium Voltage Multiphase Motor Drive System

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2016-04-01

    Full Text Available A multiphase motor has several major advantages, such as high reliability, fault tolerance, and high power density. It is a critical issue to develop a reliable and efficient multiphase motor drive system. In this paper, a transformerless voltage source converter-based drive system for a medium-voltage (MV multiphase motor is proposed. This drive converter employs cascaded H-bridge rectifiers loaded by H-bridge inverters as the interface between the grid and multiphase motor. The cascaded H-bridge rectifier technique makes the drive system able to be directly connected to the MV grid without the phase-shifting transformer because it can offset the voltage level gap between the MV grid and the semiconductor devices, provide near-sinusoidal AC terminal voltages without filters, and draw sinusoidal line current from the grid. Based on a digital signal processor (DSP, a complete improved Phase Disposition Pulse Width Modulation (PD-PWM method is developed to ensure the individual DC-link capacitor voltage balancing for enhancing the controllability and limiting the voltage and power stress on the H-bridge cells. A downscaled prototype is designed and developed based on a nine-phase motor. The experimental results verify the excellent performances of the proposed drive system and control strategy in steady-state and variant-frequency startup operations.

  8. Downhole multiphase metering in wells by means of soft-sensing

    NARCIS (Netherlands)

    Leskens, M.; Kruif, B. de; Belfroid, S.P.C.; Smeulers, J.P.M.; Gryzlov, A.

    2008-01-01

    Multiphase flow meters are indispensable tools for achieving optimal operation and control of wells as these meters deliver real-time information about their performance. For example, multiphase flow meters located downhole can improve the production of multilateral and multizone wells by timely

  9. Development of axisymmetric lattice Boltzmann flux solver for complex multiphase flows

    Science.gov (United States)

    Wang, Yan; Shu, Chang; Yang, Li-Ming; Yuan, Hai-Zhuan

    2018-05-01

    This paper presents an axisymmetric lattice Boltzmann flux solver (LBFS) for simulating axisymmetric multiphase flows. In the solver, the two-dimensional (2D) multiphase LBFS is applied to reconstruct macroscopic fluxes excluding axisymmetric effects. Source terms accounting for axisymmetric effects are introduced directly into the governing equations. As compared to conventional axisymmetric multiphase lattice Boltzmann (LB) method, the present solver has the kinetic feature for flux evaluation and avoids complex derivations of external forcing terms. In addition, the present solver also saves considerable computational efforts in comparison with three-dimensional (3D) computations. The capability of the proposed solver in simulating complex multiphase flows is demonstrated by studying single bubble rising in a circular tube. The obtained results compare well with the published data.

  10. Effectiveness of the ProTaper Universal Retreatment™ system for removing a 10-year-old filling material.

    Science.gov (United States)

    Aguiar, C; Bernart, F; Lima, G; Câmara, A

    2012-01-01

    The aim of the present study was to evaluate the effectiveness of the ProTaper Universal Retreatment™ system and the manual technique for removing a 10-year-old filling material. Twenty mesiobuccal canals of mandibular first molars with curvature degrees ranging from 20° to 35° were instrumented by the Double-Flared Instrumentation Technique with the NitiFlex files. The root canals were dried with sterile paper points and filled with gutta-percha and a zinc oxide-eugenol-based sealer using a cold lateral condensation technique. Accesses to the cavities were temporarily sealed with Cavit. The teeth were embedded in gauze containing saline solution, which was renewed every 2 weeks, and were stored at 37 °C in 100% humidity for 10 years. Buccolingual and mesiodistal radiographs were taken to evaluate the quality of the root canal filling. The radiographs were mounted in slide frames to allow them to be evaluated by the three examiners, who were specialists in endodontics. Only the specimens in whom there was agreement between the three evaluators were included in the study. The specimens were divided into 2 groups with 10 root canals each, according to gutta-percha removal techniques: Group 1: ProTaper Universal Retreatment™ system; Group 2: Hedström and K-files. Buccolingual and mesiodistal radiographs were taken and evaluated by three examiners who determined the effectiveness of the removal of the filling material. The presence of material was measured according to a score scale. Data were analyzed statistically by Fisher's exact test at 5% significance level. There were no statistical differences between the two methods in the coronal (P=0.211), and middle (P=0.266) thirds, but there were statistical differences between the two methods in the apical third (P=0.038). Not one of the experimental techniques promoted complete removal of the filling materials. The manual technique with K-file and Hedström files achieved better results than the Pro

  11. Uso de obturadores en cirugía oral y maxilofacial: Presentación de cinco casos clínicos Use of obturators in oral and maxillofacial surgery: A report of five cases

    Directory of Open Access Journals (Sweden)

    R.T. Velázquez-Cayón

    2011-03-01

    Full Text Available Los defectos creados en el maxilar, principalmente tras cirugía resectiva de tumores malignos, traumatismo o defectos congénitos, deben ser corregidos con el fin de recuperar los consecuentes déficits en el habla, la deglución, la masticación y la estética. Para ello contamos con dos amplias posibilidades: reconstrucción quirúrgica o colocación de un obturador protésico maxilar. En este artículo llevamos a cabo una revisión de la literatura reciente y clásica sobre obturadores palatinos, ilustrándola mediante 5 casos clínicos con esta opción terapéutica. Hemos encontrado descritas una amplia variedad de modificaciones para los distintos tipos de obturadores, como la fabricación de aletas nasales, colocación de obturadores de forma inmediata tras la cirugía, el hecho de ahuecar el aditamento obturador, etc. En nuestra práctica hemos observado una serie de ventajas en la colocación de este tipo de prótesis de forma posquirúrgica diferida y en estrecha colaboración con su médico responsable.Defects created in the maxillary bone, principally after surgical resection of malignant tumors, trauma or congenital defects, must be corrected to eliminate the resulting speech, swallowing, and chewing defects and restore the cosmetic appearance. Two major options available are surgical reconstruction or the placement of a maxillary obturator prosthesis. The recent and classic literature on palatal obturators is reviewed and five clinical cases treated with a palatal obturator are reported. A large variety of modifications have been reported for different types of obturators, such as nasal wings, immediate postoperative obturator prosthesis placement, etc. In the authors' experience, deferred postoperative obturator placement in close collaboration with the responsible doctor has advantages.

  12. Comparison of quality of obturation and instrumentation time using hand files and two rotary file systems in primary molars: A single-blinded randomized controlled trial.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G

    2017-01-01

    In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.

  13. Axisymmetric multiphase lattice Boltzmann method for generic equations of state

    NARCIS (Netherlands)

    Reijers, S.A.; Gelderblom, H.; Toschi, F.

    2016-01-01

    We present an axisymmetric lattice Boltzmann model based on the Kupershtokh et al. multiphase model that is capable of solving liquid–gas density ratios up to 103. Appropriate source terms are added to the lattice Boltzmann evolution equation to fully recover the axisymmetric multiphase conservation

  14. Development of Next Generation Multiphase Pipe Flow Prediction Tools

    Energy Technology Data Exchange (ETDEWEB)

    Cem Sarica; Holden Zhang

    2006-05-31

    The developments of oil and gas fields in deep waters (5000 ft and more) will become more common in the future. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas, oil and water possibly along with sand, hydrates, and waxes). Multiphase flow prediction tools are essential for every phase of hydrocarbon recovery from design to operation. Recovery from deep-waters poses special challenges and requires accurate multiphase flow predictive tools for several applications, including the design and diagnostics of the production systems, separation of phases in horizontal wells, and multiphase separation (topside, seabed or bottom-hole). It is crucial for any multiphase separation technique, either at topside, seabed or bottom-hole, to know inlet conditions such as flow rates, flow patterns, and volume fractions of gas, oil and water coming into the separation devices. Therefore, the development of a new generation of multiphase flow predictive tools is needed. The overall objective of the proposed study is to develop a unified model for gas-oil-water three-phase flow in wells, flow lines, and pipelines to predict flow characteristics such as flow patterns, phase distributions, and pressure gradient encountered during petroleum production at different flow conditions (pipe diameter and inclination, fluid properties and flow rates). In the current multiphase modeling approach, flow pattern and flow behavior (pressure gradient and phase fractions) prediction modeling are separated. Thus, different models based on different physics are employed, causing inaccuracies and discontinuities. Moreover, oil and water are treated as a pseudo single phase, ignoring the distinct characteristics of both oil and water, and often resulting in inaccurate design that leads to operational problems. In this study, a new model is being developed through a theoretical and experimental study employing a revolutionary approach. The

  15. Modeling reproducibility of porescale multiphase flow experiments

    Science.gov (United States)

    Ling, B.; Tartakovsky, A. M.; Bao, J.; Oostrom, M.; Battiato, I.

    2017-12-01

    Multi-phase flow in porous media is widely encountered in geological systems. Understanding immiscible fluid displacement is crucial for processes including, but not limited to, CO2 sequestration, non-aqueous phase liquid contamination and oil recovery. Microfluidic devices and porescale numerical models are commonly used to study multiphase flow in biological, geological, and engineered porous materials. In this work, we perform a set of drainage and imbibition experiments in six identical microfluidic cells to study the reproducibility of multiphase flow experiments. We observe significant variations in the experimental results, which are smaller during the drainage stage and larger during the imbibition stage. We demonstrate that these variations are due to sub-porescale geometry differences in microcells (because of manufacturing defects) and variations in the boundary condition (i.e.,fluctuations in the injection rate inherent to syringe pumps). Computational simulations are conducted using commercial software STAR-CCM+, both with constant and randomly varying injection rate. Stochastic simulations are able to capture variability in the experiments associated with the varying pump injection rate.

  16. Multi-phase AC/AC step-down converter for distribution systems

    Science.gov (United States)

    Aeloiza, Eddy C.; Burgos, Rolando P.

    2017-10-25

    A step-down AC/AC converter for use in an electric distribution system includes at least one chopper circuit for each one of a plurality of phases of the AC power, each chopper circuit including a four-quadrant switch coupled in series between primary and secondary sides of the chopper circuit and a current-bidirectional two-quadrant switch coupled between the secondary side of the chopper circuit and a common node. Each current-bidirectional two-quadrant switch is oriented in the same direction, with respect to the secondary side of the corresponding chopper circuit and the common node. The converter further includes a control circuit configured to pulse-width-modulate control inputs of the switches, to convert a first multiphase AC voltage at the primary sides of the chopper circuits to a second multiphase AC voltage at the secondary sides of the chopper circuits, the second multiphase AC voltage being lower in voltage than the first multiphase AC voltage.

  17. Electrification of particulates in industrial and natural multiphase flows

    CERN Document Server

    Gu, Zhaolin

    2017-01-01

    This book introduces comprehensive fundamentals, numerical simulations and experimental methods of electrification of particulates entrained multiphase flows. The electrifications of two particulate forms, liquid droplets and solid particles, are firstly described together. Liquid droplets can be charged under preset or associated electric fields, while solid particles can be charged through contact. Different charging ways in gas (liquid)-liquid or gas-solid multiphase flows are summarized, including ones that are beneficial to industrial processes, such as electrostatic precipitation, electrostatic spraying, and electrostatic separation, etc., ones harmful for shipping and powder industry, and ones occurring in natural phenomenon, such as wind-blown sand and thunderstorm. This book offers theoretical references to the control and utilization of the charging or charged particulates in multiphase flows as well.

  18. Orthograde retreatment failure with extruded MTA apical plug in a large periradicular lesion followed by surgical intervention: case report.

    Science.gov (United States)

    Brito-Junior, Manoel; Faria-e-Silva, Andre Luis; Quintino, Alex Carvalho; Moreira-Junior, Gil; Geber, Mauro; Camilo, Carla Cristina; Soares, Janir Alves

    2012-01-01

    Absence of periapical healing after orthograde retreatment using an apical plug with mineral trioxide aggregate (MTA) can require surgical intervention. A patient with a root-filled maxillary central incisor with chronic apical periodontitis and sinus tract was referred for endodontic retreatment. Excessive apical enlargement was verified, indicating an MTA apical plug placement; however, an unintentional extrusion of MTA occurred during this step. The root canal was filled with gutta-percha and sealer, and periodic recalls were scheduled. The sinus tract was observed after six months and the lesion remained unaltered, although the extruded MTA had resorbed; therefore, an apicoectomy and retrograde root-end filling with MTA were performed. Absence of sinus tract, normal clinical aspect, and complete repair of the lesion were observed at the two-year follow-up.

  19. Endodontic treatment of a maxillary lateral incisor with a perforating internal resorption by using cone beam computed tomography as a diagnostic aid: a case report.

    Science.gov (United States)

    Takita, Toshiya; Tsurumachi, Tamotsu; Ogiso, Bunnai

    2011-10-01

    This case report presents the endodontic treatment of a maxillary right lateral incisor with a perforating internal resorption in a 50-year-old woman. Radiographically, internal resorption appears as a fairly uniform, radiolucent enlargement of the pulp canal and distortion of the original root canal outline. The use of cone beam computed tomography can help the clinician in making a confirmatory diagnosis and determining the treatment plan before undertaking the actual treatment. After cleaning the root canal space and the resorptive defect by mechanic instrumentation, irrigation, and interim calcium hydroxide dressing, the apical third canal was filled with a gutta-percha point by lateral condensation. The resorptive defect was filled with mineral trioxide aggregate. Follow-up radiographs at 3 years showed adequate repair of the resorption, and the tooth remained asymptomatic.

  20. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (pProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary

  1. Persistent groin pain following a trans-obturator sling procedure for stress urinary incontinence: a diagnostic and therapeutic challenge

    NARCIS (Netherlands)

    Hazewinkel, Menke H.; Hinoul, Piet; Roovers, Jan-Paul

    2009-01-01

    Groin pain after a tension-free vaginal tape-obturator (TVT-O) procedure can occur but mostly disappears within 4 weeks. Persistent groin pain is extremely rare and there is a paucity of literature on how to diagnose and manage this adverse event. We present two cases with severe persistent groin

  2. Multiphase porous media modelling: A novel approach to predicting food processing performance.

    Science.gov (United States)

    Khan, Md Imran H; Joardder, M U H; Kumar, Chandan; Karim, M A

    2018-03-04

    The development of a physics-based model of food processing is essential to improve the quality of processed food and optimize energy consumption. Food materials, particularly plant-based food materials, are complex in nature as they are porous and have hygroscopic properties. A multiphase porous media model for simultaneous heat and mass transfer can provide a realistic understanding of transport processes and thus can help to optimize energy consumption and improve food quality. Although the development of a multiphase porous media model for food processing is a challenging task because of its complexity, many researchers have attempted it. The primary aim of this paper is to present a comprehensive review of the multiphase models available in the literature for different methods of food processing, such as drying, frying, cooking, baking, heating, and roasting. A critical review of the parameters that should be considered for multiphase modelling is presented which includes input parameters, material properties, simulation techniques and the hypotheses. A discussion on the general trends in outcomes, such as moisture saturation, temperature profile, pressure variation, and evaporation patterns, is also presented. The paper concludes by considering key issues in the existing multiphase models and future directions for development of multiphase models.

  3. Viscous and gravitational fingering in multiphase compositional and compressible flow

    Science.gov (United States)

    Moortgat, Joachim

    2016-03-01

    Viscous and gravitational fingering refer to flow instabilities in porous media that are triggered by adverse mobility or density ratios, respectively. These instabilities have been studied extensively in the past for (1) single-phase flow (e.g., contaminant transport in groundwater, first-contact-miscible displacement of oil by gas in hydrocarbon production), and (2) multi-phase immiscible and incompressible flow (e.g., water-alternating-gas (WAG) injection in oil reservoirs). Fingering in multiphase compositional and compressible flow has received much less attention, perhaps due to its high computational complexity. However, many important subsurface processes involve multiple phases that exchange species. Examples are carbon sequestration in saline aquifers and enhanced oil recovery (EOR) by gas or WAG injection below the minimum miscibility pressure. In multiphase flow, relative permeabilities affect the mobility contrast for a given viscosity ratio. Phase behavior can also change local fluid properties, which can either enhance or mitigate viscous and gravitational instabilities. This work presents a detailed study of fingering behavior in compositional multiphase flow in two and three dimensions and considers the effects of (1) Fickian diffusion, (2) mechanical dispersion, (3) flow rates, (4) domain size and geometry, (5) formation heterogeneities, (6) gravity, and (7) relative permeabilities. Results show that fingering in compositional multiphase flow is profoundly different from miscible conditions and upscaling techniques used for the latter case are unlikely to be generalizable to the former.

  4. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain

    Directory of Open Access Journals (Sweden)

    Chye CL

    2015-03-01

    Full Text Available Cien-Leong Chye,1 Cheng-Loong Liang,1 Kang Lu,1 Ya-Wen Chen,2,3 Po-Chou Liliang1 1Department of Neurosurgery, E-Da Hospital, I-Shou University, 2Department of Nursing, I-Shou University, 3School of Nursing, Kaohsiung Medical University, Kaohsiung, Taiwan Purpose: Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain.Patients and methods: Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS, Oxford hip scores (OHS, and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment.Results: At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement.Conclusion: When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning. Keywords: pulsed radiofrequency, obturator and femoral nerves, hip joint pain, osteoar­thritis

  5. Multiphase flow analysis using population balance modeling bubbles, drops and particles

    CERN Document Server

    Yeoh, Guan Heng; Tu, Jiyuan

    2013-01-01

    Written by leading multiphase flow and CFD experts, this book enables engineers and researchers to understand the use of PBM and CFD frameworks. Population balance approaches can now be used in conjunction with CFD, effectively driving more efficient and effective multiphase flow processes. Engineers familiar with standard CFD software, including ANSYS-CFX and ANSYS-Fluent, will be able to use the tools and approaches presented in this book in the effective research, modeling and control of multiphase flow problems. Builds a complete understanding of the theory behind the

  6. Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.

    Science.gov (United States)

    Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua

    2016-08-01

    We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.

  7. Carbon-steel corrosion in multiphase slug flow and CO2

    International Nuclear Information System (INIS)

    Villarreal, J.; Laverde, D.; Fuentes, C.

    2006-01-01

    Hydrocarbon multiphase flow may exhibit various geometric configurations or flow patterns. One of these flow patterns is known as multiphase slug flow. If CO 2 is present in hydrocarbons, the steel pipelines can be corroded as this process is probably enhanced by slug flow turbulence. A hydrodynamic circuit was built to study the CO 2 corrosion rates under different slug flow conditions. The experimental results show how the corrosion rate of a carbon-steel electrode varies according to the flow turbulence. The higher slug frequency used in this study was 80 slugs/min. Experimental results for pressure drop and slug length are in agreement with the Dukler and Hubbard [A model for gas-liquid slug flow in horizontal and near horizontal tubes, Ind. Eng. Chem. Fundam. 14 (1975) 337-347] multiphase flow model. Furthermore, the experimental slug frequencies are well correlated by the Shell and Gregory [Correlation of the liquid volume fraction in the slug for horizontal gas-liquid slug flow. Int. J. Multiphase Flow 4 (1978) 33-39] equations in horizontal pipes

  8. Clinical significance of multiphase skeletal scintiscanning

    International Nuclear Information System (INIS)

    Zimmermann, P.

    1984-01-01

    A total of 61 patients were included in this study, which was performed to find out, if multiphase skeletal scintiscanning using 99mTc-DPD is a more accurate investigational method in terms of diagnostic differentiation than conventional scintiscanning. All patients were subjected to additional diagnostic procedures using X-rays, CT, etc. and the findings revealed were compared. In order to ensure an objective assessment of the density patterns obtained in the individual study phase (initial phase (1); vascular phase (2); soft tissue phase (3); standard phase (4)), special care was taken that only regions of similar vascularity were compared. In acute osteomyelitis, osteitis deformans according to Paget and osteoid osteoma multiphase scintiscanning yielded valuable additional information which, from the diagnostic point of view, proved to be much more meaningful than that provided by conventional scintiscanning, as very characteristic activity patterns were discernible in the initial study phases. In patients showing artificial limb infection or fractures this supplementary information was also found to be of some value, although the behaviour of activity in the initial study phases gave less conclusive evidence here than in the diseases mentioned before. In inflammatory disorders involving only minor histological changes or those of a chronic nature as well as in special forms of inflammation and artificial limb dislocation multiphase scintiscanning was not found to offer any advantages over conventional scintiscanning. (TRV) [de

  9. Pattern recognition techniques for horizontal and vertically upward multiphase flow measurement

    Science.gov (United States)

    Arubi, Tesi I. M.; Yeung, Hoi

    2012-03-01

    The oil and gas industry need for high performing and low cost multiphase meters is ever more justified given the rapid depletion of conventional oil reserves that has led oil companies to develop smaller and marginal fields and reservoirs in remote locations and deep offshore, thereby placing great demands for compact and more cost effective solutions of on-line continuous multiphase flow measurement for well testing, production monitoring, production optimisation, process control and automation. The pattern recognition approach for clamp-on multiphase measurement employed in this study provides one means for meeting this need. High speed caesium-137 radioisotope-based densitometers were installed vertically at the top of a 50.8mm and 101.6mm riser as well as horizontally at the riser base in the Cranfield University multiphase flow test facility. A comprehensive experimental campaign comprising flow conditions typical of operating conditions found in the Petroleum Industry was conducted. The application of a single gamma densitometer unit, in conjunction with pattern recognition techniques to determine both the phase volume fractions and velocities to yield the individual phase flow rates of horizontal and vertically upward multiphase flows was investigated. The pattern recognition systems were trained to map the temporal fluctuations in the multiphase mixture density with the individual phase flow rates using statistical features extracted from the gamma counts signals as their inputs. Initial results yielded individual phase flow rate predictions to within ±5% relative error for the two phase airwater flows and ±10% for three phase air-oil-water flows data.

  10. Twenty-five years of modeling multiphase flow and heat transfer

    International Nuclear Information System (INIS)

    Lyczkowski, R.W.

    1999-01-01

    This presentation will cover some of the highlights of multiphase modeling in collaboration with Professor Dimitri Gidaspow (DG) over the last roughly twenty-five years. It all started in 1972 in Idaho Falls with Charles Solbrig, who planned and initiated a project for the former USAEC to develop a computer code to replace RELAP4 to analyze the loss of coolant accident (LOCA). DG spent his sabbatical on the project in 1973. One highlight was the discovery of complex characteristics, the implications of which are still pondered by some. Fluidization research began in 1978 when the author collaboratively developed a step-by-step building-block approach to understanding the hydrodynamics of fluidized beds, an approach closely coupled to validation experiments. A grant from the USDOE to study solids circulation around a jet in a fluidized bed was awarded to DG in 1978. Following that, grants from GRI, NSF, and a contract from Westinghouse Electric Corp. allowed the early work to continue. Progress was slow since computer costs were high. Subsequent continuing support from the USDOE, NSF, EPRI, and industry has allowed research to continue, as has his collaboration. A highlight of this collaboration was the development of the monolayer energy dissipation (MED) erosion model. Multiphase flow and fluidization theory took quantum leaps with the publication of DG's Multiphase Flow and Fluidization: Continuum and Kinetic Theory Descriptions (MFF), Academic Press, San Diego (1994), for which there is essentially no competition. Only the late Professor S.L. Soo's Particulates and Continuum: Multiphase Fluid Dynamics, Hemisphere Publishing Corp., New York (1989), a textbook version of the classic monograph Multiphase Fluid Dynamics, Science Press, Beijing, China (1990), comes close. In MFF, the kinetic theory of granular flow has evolved as a potentially viable adjunct to the continuum multiphase theory, of which fluidization is one important manifestation. It must be

  11. A Cell-Centered Multiphase ALE Scheme With Structural Coupling

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Timothy Alan [Univ. of California, Davis, CA (United States)

    2012-04-16

    A novel computational scheme has been developed for simulating compressible multiphase flows interacting with solid structures. The multiphase fluid is computed using a Godunov-type finite-volume method. This has been extended to allow computations on moving meshes using a direct arbitrary-Eulerian- Lagrangian (ALE) scheme. The method has been implemented within a Lagrangian hydrocode, which allows modeling the interaction with Lagrangian structural regions. Although the above scheme is general enough for use on many applications, the ultimate goal of the research is the simulation of heterogeneous energetic material, such as explosives or propellants. The method is powerful enough for application to all stages of the problem, including the initial burning of the material, the propagation of blast waves, and interaction with surrounding structures. The method has been tested on a number of canonical multiphase tests as well as fluid-structure interaction problems.

  12. Multiphase Microfluidics The Diffuse Interface Model

    CERN Document Server

    2012-01-01

    Multiphase flows are typically described assuming that the different phases are separated by a sharp interface, with appropriate boundary conditions. This approach breaks down whenever the lengthscale of the phenomenon that is being studied is comparable with the real interface thickness, as it happens, for example, in the coalescence and breakup of bubbles and drops, the wetting and dewetting of solid surfaces and, in general, im micro-devices. The diffuse interface model resolves these probems by assuming that all quantities can vary continuously, so that interfaces have a non-zero thickness, i.e. they are "diffuse". The contributions in this book review the theory and describe some relevant applications of the diffuse interface model for one-component, two-phase fluids and for liquid binary mixtures, to model multiphase flows in confined geometries.

  13. Multiphase composite coatings: structure and properties

    International Nuclear Information System (INIS)

    Yurov, V M; Guchenko, S A; Platonova, E S; Syzdykova, A Sh; Lysenko, E N

    2015-01-01

    The paper discusses the results of the research into the formation of ion-plasma multiphase coatings. The types of the formed structures are found to be not so diverse, as those formed, for example, in alloy crystallization. The structures observed are basically of globular type and, more rarely, of unclosed dissipative and cellular structures. It is shown that the properties of the coating formed in deposition are largely determined by its surface energy or surface tension. Since the magnitude of the surface tension (surface energy) in most cases is an additive quantity, each of the elements of the coating composition contributes to the total surface energy. In case of simultaneous sputtering of multiphase cathodes, high entropy coatings with an ordered cellular structure and improved mechanical properties are formed. (paper)

  14. Direct numerical simulations of gas-liquid multiphase flows

    CERN Document Server

    Tryggvason, Grétar; Zaleski, Stéphane

    2011-01-01

    Accurately predicting the behaviour of multiphase flows is a problem of immense industrial and scientific interest. Modern computers can now study the dynamics in great detail and these simulations yield unprecedented insight. This book provides a comprehensive introduction to direct numerical simulations of multiphase flows for researchers and graduate students. After a brief overview of the context and history the authors review the governing equations. A particular emphasis is placed on the 'one-fluid' formulation where a single set of equations is used to describe the entire flow field and

  15. Multiphase Return Trajectory Optimization Based on Hybrid Algorithm

    Directory of Open Access Journals (Sweden)

    Yi Yang

    2016-01-01

    Full Text Available A hybrid trajectory optimization method consisting of Gauss pseudospectral method (GPM and natural computation algorithm has been developed and utilized to solve multiphase return trajectory optimization problem, where a phase is defined as a subinterval in which the right-hand side of the differential equation is continuous. GPM converts the optimal control problem to a nonlinear programming problem (NLP, which helps to improve calculation accuracy and speed of natural computation algorithm. Through numerical simulations, it is found that the multiphase optimal control problem could be solved perfectly.

  16. Comparação entre sessão única e a utilização do "curativo de demora" no tratamento endodôntico em cães: aspectos histopatológicos e microbiológicos Comparison of the application of temporary endodontic dressing in teeth of dogs: histopathological and microbiological aspects

    Directory of Open Access Journals (Sweden)

    Léslie M. Domingues-Falqueiro

    2007-05-01

    present study was to evaluate the endodontic treatment in one or two sessions, using calcium hydroxide plus camphorated paramonochlorophenol (CMCP with temporary endodontic medicaments. Four dogs were used, and two animals were submitted the treatment in one session only and the others in two sessions. Premolar teeth were used in this study: second and third upper premolar teeth and second, third and fourth lower premolar teeth were divided into two groups. Opening of the pulp chamber was performed with burns, and the pulp was exposed for 60 days. After this period the group treated in only session was obtured with gutta-percha and zinc oxide and eugenol, and the group treated in two sessions received the CMCP that remained in the canal per 30 days and was afterwards obtured with the material of the other group. Clinical and radiographical control was performed twice a week, and after 60 days a small block containing the teeth, surrounding periapical tissues and the periodontium was removed for histological and microbiological study. Histological analysis revealed intense inflammatory response in both groups. Microbiological analysis showed a more severe microbial reduction in the group treated in one session. However, bacteria were still observed in the two groups, indicating that none of the treatments presented total efficiency.

  17. A Comparative Study of Apical Healing of Open Apices Using MTA and Ca(OH2 Apical Plugs in Cats

    Directory of Open Access Journals (Sweden)

    M. H. Zarrabi

    2005-06-01

    Full Text Available Statement of problem: Endodontic treatment of necrotic teeth with open apices is a challenge. After ruling out surgery as a treatment scheme and introduction of the multivisit apexification which in turn had its disadvantages, apical plug seems to be a suitable substitute treatment plan for such cases. Apical plug makes the treatment through formation of a barrier against the obturating material in a single visit.Purpose: The purpose of this study was to compare histologically the periapical healing using MTA and calcium hydroxide apical plugs after intervals of 4 and 12 weeks in cats.Materials and Methods: In this clinical trial study 64 canines of 16 healthy and mature cats were divided into 3 groups after a periapical lesion formation by over instrumentation in the apical area with files up to no.120. The first group included 24 teeth on which MTA apical plug was applied. The second group included 24 teeth on which Ca (OH 2 apical plug was applied. In both groups the canals were filled with gutta percha and sealer. The third group included 16 control teeth whose canals were left empty after instrumentation and debridement. The access cavities of all teeth were sealed with varnish and amalgam and the vital perfusion of cats was performed in 4 and 12 week intervals. Statistical analysis was established by χ2 and independence test.Results: After 4 weeks, periapical healing in the first group was 90%, in the second group 80% and in the third group, it was only 12.5 %. After 12 weeks, periapical healing occurred in 100% of the MTA group, while it was 57.1% in the second and 40%in the third group .Generally, in the study of histological parameters of healing, no statistical significant difference was observed between the 2 experimental groups,although the MTA group results were much better than the Ca (OH 2 group especially at 12 weeks.Conclusion: The use of MTA apical plug is more effective than Ca (OH 2 in treatment of necrotic teeth with open

  18. Coronal microleakage with five different temporary restorative materials following walking bleach technique: An ex-vivo study

    Directory of Open Access Journals (Sweden)

    G. P. V Srikumar

    2012-01-01

    Full Text Available Context: Walking bleach technique uses 30% hydrogen peroxide and sodium perborate, and this paste mixture causes loosening of the coronal temporary restorative materials and thus decreasing its clinical effectiveness and causing irritation to the patients oral tissues. In the present study, sealing ability of hygroscopic coronal temporary restorative materials were compared with the other commonly used temporary restorative materials. Aim: To evaluate the effects of walking bleach material on the marginal sealing ability and coronal microleakage of the hydrophilic temporary restorative materials with that of the other commonly used temporary restorative materials in endodontic practice. Materials and Methods: Seventy-five extracted human maxillary central incisor teeth were prepared chemo-mechanically and obturated with gutta-percha in lateral condensation technique. Surface of each tooth was double coated with cyanoacrylate glue. All the teeth were randomly divided in to five groups. Out of 15 teeth in each group, 10 teeth served as experimental specimens, in which bleaching agent was placed in the pulp chamber and 5 teeth served as control, in which no bleaching agent was placed. The access cavities were restored with temporary restorative materials being tested per each group respectively. The specimens were then immersed in 1% India ink dye and subjected to thermo cycling for 7 days. All the teeth were longitudinally sectioned and observed with stereomicroscope and were graded according to the depth of linear dye penetration. Statistical Analysis Used: Mann-Whitney U test and Kruskal-Wallis test. Results: Hydrophilic temporary restorative materials Cavit G and Coltosol F have shown minimal coronal dye leakage with better sealing ability when exposed to walking bleach paste mixture in the dye penetration tests compared to other commonly used temporary restorative materials. Conclusion: Marginal sealing ability of Cavit G and Coltosol F were

  19. Multiphase-Multifunctional Ceramic Coatings

    Science.gov (United States)

    2013-06-30

    systems for high temperatura applications” “ Estudios de Ferroelasticidad en Sistemas Cerámicos Multifásicos para Aplicaciones en Alta Temperatura ...Ceramic Coatings Performing Organization names: Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional – Unidad Queretaro...materials, Cinvestav. Thesis: “Ferroelasticity studies in multiphase ceramic systems for high temperatura applications”. Her work mainly focused in the

  20. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  1. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  2. [Modern tendencies in surgical treatment of patients with obturation jaundice complicated by hepatic insufficiency].

    Science.gov (United States)

    Starosek, V N; Khil'ko, S S; Vlakhov, A K

    2009-04-01

    The article is devoted to the problem of efficacy of the hepatic insufficiency (HI) prophylaxis and treatment methods in obturation jaundice. The role of energy-depending processes and the oxygen deficiency in tissues in the HI occurrence and progressing, the possibilities of medicinal correction of such disorders were studied up. The authors follow the concept of expediency of the oxygen-bearing preparations, which improve the erythrocytes function and oxygen delivery to the tissues in combination with miniinvasive decompression of bilioefferent ways, incorporation into the treatment complex of HI of mechanic genesis.

  3. Application and Perspectives of Multiphase Induction Motors

    Directory of Open Access Journals (Sweden)

    Benas Kundrotas

    2012-04-01

    Full Text Available The article considers the areas of applying multiphase induction motors. Their advantages against three phase motors have become the main reason for employing them in multiphase drives. The paper deals with the six-phase induction motor having two similar three phase windings in the stator shifted by 30 degrees in space and three phase windings in the rotor. Differential equations for this motor are presented and transformed to dq synchronous reference frame. The transformed equations are expressed in a matrix form and solved by MATLAB software using the Dormand-Prince (ode45 method. The transient characteristics of the torque, speed and current of the six-phase induction motor are calculated and discussed.Article in Lithuanian

  4. How winning changes motivation in multiphase competitions.

    Science.gov (United States)

    Huang, Szu-Chi; Etkin, Jordan; Jin, Liyin

    2017-06-01

    What drives motivation in multiphase competitions? Adopting a dynamic approach, this research examines how temporary standing-being ahead of (vs. behind) one's opponent-in a multiphase competition shapes subsequent motivation. Six competitions conducted in the lab and in the field demonstrate that the impact of being ahead on contestants' motivation depends on when (i.e., in which phase of the competition) contestants learn they are in the lead. In the early phase, contestants are concerned about whether they can win; being ahead increases motivation by making winning seem more attainable. In the later phase, however, contestants are instead driven by how much additional effort they believe they need to invest; being ahead decreases motivation by reducing contestants' estimate of the remaining effort needed to win. Temporary standing thus has divergent effects on motivation in multiphase competitions, driven by a shift in contestants' main concern from the early to the later phase and thus the meaning they derive from being ahead of their opponent. By leveraging insights gained from approaching individuals' self-regulation as a dynamic process, this research advances understanding of how motivation evolves in a unique interdependent self-regulatory context. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Continuum-Kinetic Models and Numerical Methods for Multiphase Applications

    Science.gov (United States)

    Nault, Isaac Michael

    This thesis presents a continuum-kinetic approach for modeling general problems in multiphase solid mechanics. In this context, a continuum model refers to any model, typically on the macro-scale, in which continuous state variables are used to capture the most important physics: conservation of mass, momentum, and energy. A kinetic model refers to any model, typically on the meso-scale, which captures the statistical motion and evolution of microscopic entitites. Multiphase phenomena usually involve non-negligible micro or meso-scopic effects at the interfaces between phases. The approach developed in the thesis attempts to combine the computational performance benefits of a continuum model with the physical accuracy of a kinetic model when applied to a multiphase problem. The approach is applied to modeling a single particle impact in Cold Spray, an engineering process that intimately involves the interaction of crystal grains with high-magnitude elastic waves. Such a situation could be classified a multiphase application due to the discrete nature of grains on the spatial scale of the problem. For this application, a hyper elasto-plastic model is solved by a finite volume method with approximate Riemann solver. The results of this model are compared for two types of plastic closure: a phenomenological macro-scale constitutive law, and a physics-based meso-scale Crystal Plasticity model.

  6. CFD Modeling of a Multiphase Gravity Separator Vessel

    KAUST Repository

    Narayan, Gautham

    2017-05-23

    The poster highlights a CFD study that incorporates a combined Eulerian multi-fluid multiphase and a Population Balance Model (PBM) to study the flow inside a typical multiphase gravity separator vessel (GSV) found in oil and gas industry. The simulations were performed using Ansys Fluent CFD package running on KAUST supercomputer, Shaheen. Also, a highlight of a scalability study is presented. The effect of I/O bottlenecks and using Hierarchical Data Format (HDF5) for collective and independent parallel reading of case file is presented. This work is an outcome of a research collaboration on an Aramco project on Shaheen.

  7. CFD Modeling of a Multiphase Gravity Separator Vessel

    KAUST Repository

    Narayan, Gautham; Khurram, Rooh Ul Amin; Elsaadawy, Ehab

    2017-01-01

    The poster highlights a CFD study that incorporates a combined Eulerian multi-fluid multiphase and a Population Balance Model (PBM) to study the flow inside a typical multiphase gravity separator vessel (GSV) found in oil and gas industry. The simulations were performed using Ansys Fluent CFD package running on KAUST supercomputer, Shaheen. Also, a highlight of a scalability study is presented. The effect of I/O bottlenecks and using Hierarchical Data Format (HDF5) for collective and independent parallel reading of case file is presented. This work is an outcome of a research collaboration on an Aramco project on Shaheen.

  8. Multiphase flows with phase change

    Indian Academy of Sciences (India)

    Multiphase flows with phase change are ubiquitous in many industrial sectors ranging from energy and infra-structure to specialty chemicals and pharmaceuticals. My own interest in mul- tiphase flows with phase change started more than 15 years ago when I had initiated work on riser reactor for fluid catalytic cracking and ...

  9. Is it possible to design universal multi-phase flow analyzer?

    International Nuclear Information System (INIS)

    Ivanov Kolev, N.

    2005-01-01

    Transient 3D-multiphase flows consisting of many chemical constituents in nature and technology (Figs. 1 and 2) are the common case of flows. In many technical applications we have to do with particular realization of the multi-phase flows like steady state flows, or single component flows or single phase flows etc. Engineers and scientists created hundreds of computer codes for description of more or less specific realizations of multi-phase flows. If one compares the structure of these codes one is astonished by the waste of the human resources for programming repeating model elements like equations of state, friction lows in variety of geometry, heat transfer coefficients, mathematical equation solvers, data handling procedures, graphical environment etc. It is hardly to expect, that the best solution for the specific sub-phenomenon is available in all codes. Looking in other branches of the technology like computer chips production we realize that the revolutionary idea of having common ''chips'' within complex applications is very far from its practical realization in the computational multi-phase flow dynamics. Following this line of arguments I expressed several times in my publications explicitly or implicitly the idea, that it is possible to create a universal multi-phase flow analyzer in the sense of computer architecture, that is capable to absorb the adequate multi-phase knowledge data base specified in Appendix 1. The subject of this paper is to summarize some of the main ideas, some of them already realized by this author, on the way of creating such computer code architecture, to illustrate haw they work, and to make an outlook regarding what are the challenges in the future developments. We confine deliberately our attention to the solution of the so called local volume and time averaged system of PDE's for a simple reason: Direct numerical resolution of interacting fluids is possible as demonstrated for small scales by many researchers, but for

  10. Evaluation of smear layer removal and marginal adaptation of root canal sealer after final irrigation using ethylenediaminetetraacetic, peracetic, and etidronic acids with different concentrations.

    Science.gov (United States)

    Ulusoy, Özgür İlke; Zeyrek, Salev; Çelik, Bülent

    2017-07-01

    The purpose of this study was to investigate the effects of different irrigation solutions on the smear layer removal and marginal adaptation of a resin-based sealer to root canal dentine. A total of 152 instrumented roots were irrigated with the following irrigants: 9,18% etidronic acid (HEBP), 0.5, 1,2% peracetic acid (PAA), 17% ethylenediaminetetraacetic acid (EDTA), saline. The amount of smear layer was evaluated using scanning electron microscope (SEM) in seventy root samples. Eighty-two roots were filled with AH Plus and gutta-percha. Slices obtained from apical third of each specimen were viewed with SEM to assess marginal adaptation. Use of 9% and 18% HEBP resulted in more efficient smear layer removal in the apical third than the other chelators (p acid is a promising candidate for final irrigation of root canals. © 2017 Wiley Periodicals, Inc.

  11. Proceedings of submicron multiphase materials

    International Nuclear Information System (INIS)

    Baney, R.; Gilliom, L.; Hirano, S.I.; Schmidt, H.

    1992-01-01

    This book contains the papers presented at Symposium R of the spring 1992 Materials Research Society meeting held in San Francisco, California. The title of the symposium, Submicron Multiphase Materials, was selected by the organizers to encompass the realm of composite materials from those smaller than conventional fiber matrix composites to those with phase separation dimensions approaching molecular dimensions. The development of composite materials is as old as the development of materials. Humans quickly learned that, by combining materials, the best properties of each can be realized and that, in fact, synergistic effects often arise. For example, chopped straw was used by the Israelites to limit cracking in bricks. The famed Japanese samurai swords were multilayers of hard oxide and tough ductile materials. One also finds in nature examples of composite materials. These range form bone to wood, consisting of a hard phase which provides strength and stiffness and a softer phase for toughness. Advanced composites are generally thought of as those which are based on a high modulus, discontinuous, chopped or woven fiber phase and a continuous polymer phase. In multiphase composites, dimensions can range from meters in materials such as steel rod-reinforced concrete structures to angstroms. In macrophase separated composite materials, properties frequently follow the rule of mixtures with the properties approximating the arithmetic mean of the properties of each individual phase, if there is good coupling between the phases. As the phases become smaller, the surface to volume ratio grows in importance with respect to properties. Interfacial and interphase phenomena being to dominate. Surface free energies play an ever increasing role in controlling properties. In recent years, much research in materials science has been directed at multiphase systems where phase separations are submicron in at least some dimension

  12. Rehabilitation of patient with acquired maxillary defect, using a closed hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Abhilasha S Bhasin

    2011-01-01

    Full Text Available Palliative care means providing support and care for patients with life-threatening or debilitating illness so that they can live their life as comfortably as possible. The fact that cure is no longer a reality does not mean that care cannot be made available. Partial maxillectomy defect presents a prosthodontic challenge in terms of re-establishing oronasal separation. Such defect has direct effect on cosmetic, function and psychology of the patient. This article describes step by step clinical and laboratory procedures involved in the rehabilitation of a hemimaxillectomy patient, using a definitive closed hollow bulb obturator, which improved his physical, emotional, functional, social and spiritual needs.

  13. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain.

    Science.gov (United States)

    Chye, Cien-Leong; Liang, Cheng-Loong; Lu, Kang; Chen, Ya-Wen; Liliang, Po-Chou

    2015-01-01

    Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF) is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain. Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment) according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS), Oxford hip scores (OHS), and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment. At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement. When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning.

  14. Application of neutron radiography to visualization of multiphase flows

    International Nuclear Information System (INIS)

    Takenaka, N.; Fujii, T.; Nishizaki, K.; Asano, H.; Ono, A.; Sonoda, K.; Akagawa, K.

    1990-01-01

    Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author)

  15. Texture analysis of T1-w and T2-w MR images allows a quantitative evaluation of radiation-induced changes of internal obturator muscles after radiotherapy for prostate cancer.

    Science.gov (United States)

    Scalco, Elisa; Rancati, Tiziana; Pirovano, Ileana; Mastropietro, Alfonso; Palorini, Federica; Cicchetti, Alessandro; Messina, Antonella; Avuzzi, Barbara; Valdagni, Riccardo; Rizzo, Giovanna

    2018-04-01

    To investigate the potential of texture analysis applied on T2-w and postcontrast T1-w images acquired before radiotherapy for prostate cancer (PCa) and 12 months after its completion in quantitatively characterizing local radiation effect on the muscular component of internal obturators, as organs potentially involved in urinary toxicity. T2-w and postcontrast T1-w MR images were acquired at 1.5 T before treatment (MRI1) and at 12 months of follow-up (MRI2) in 13 patients treated with radiotherapy for PCa. Right and left internal obturator muscle contours were manually delineated upon MRI1 and then automatically propagated on MRI2 by an elastic registration method. Planning CT images were coregistered to both MRIs and dose maps were deformed accordingly. A high-dose region receiving >55 Gy and a low-dose region receiving evaluated. A signal increase was highlighted in both T2-w and T1-w images in the portion of the obturators near the prostate, i.e., in the region receiving medium-high doses. A change in the spatial organization was identified, as an increase in homogeneity and a decrease in contrast and complexity, compatible with an inflammatory status. In particular, the region receiving medium-high doses presented more significant or, at least, stronger differences. Texture analysis applied on T1-w and T2-w MR images has demonstrated its ability in quantitative evaluating radiation-induced changes in obturator muscles after PCa radiotherapy. © 2018 American Association of Physicists in Medicine.

  16. Accurate solution algorithms for incompressible multiphase flows

    International Nuclear Information System (INIS)

    Rider, W.J.; Kothe, D.B.; Mosso, S.J.; Cerutti, J.H.; Hochstein, J.I.

    1994-01-01

    A number of advances in modeling multiphase incompressible flow are described. These advances include high-order Godunov projection methods, piecewise linear interface reconstruction and tracking and the continuum surface force model. Examples are given

  17. Modeling variability in porescale multiphase flow experiments

    Science.gov (United States)

    Ling, Bowen; Bao, Jie; Oostrom, Mart; Battiato, Ilenia; Tartakovsky, Alexandre M.

    2017-07-01

    Microfluidic devices and porescale numerical models are commonly used to study multiphase flow in biological, geological, and engineered porous materials. In this work, we perform a set of drainage and imbibition experiments in six identical microfluidic cells to study the reproducibility of multiphase flow experiments. We observe significant variations in the experimental results, which are smaller during the drainage stage and larger during the imbibition stage. We demonstrate that these variations are due to sub-porescale geometry differences in microcells (because of manufacturing defects) and variations in the boundary condition (i.e., fluctuations in the injection rate inherent to syringe pumps). Computational simulations are conducted using commercial software STAR-CCM+, both with constant and randomly varying injection rates. Stochastic simulations are able to capture variability in the experiments associated with the varying pump injection rate.

  18. Non-Equilibrium Thermodynamics in Multiphase Flows

    CERN Document Server

    Mauri, Roberto

    2013-01-01

    Non-equilibrium thermodynamics is a general framework that allows the macroscopic description of irreversible processes. This book introduces non-equilibrium thermodynamics and its applications to the rheology of multiphase flows. The subject is relevant to graduate students in chemical and mechanical engineering, physics and material science. This book is divided into two parts. The first part presents the theory of non-equilibrium thermodynamics, reviewing its essential features and showing, when possible, some applications. The second part of this book deals with how the general theory can be applied to model multiphase flows and, in particular, how to determine their constitutive relations. Each chapter contains problems at the end, the solutions of which are given at the end of the book. No prior knowledge of statistical mechanics is required; the necessary prerequisites are elements of transport phenomena and on thermodynamics. “The style of the book is mathematical, but nonetheless it remains very re...

  19. Constitutive relationships and models in continuum theories of multiphase flows

    International Nuclear Information System (INIS)

    Decker, R.

    1989-09-01

    In April, 1989, a workshop on constitutive relationships and models in continuum theories of multiphase flows was held at NASA's Marshall Space Flight Center. Topics of constitutive relationships for the partial or per phase stresses, including the concept of solid phase pressure are discussed. Models used for the exchange of mass, momentum, and energy between the phases in a multiphase flow are also discussed. The program, abstracts, and texts of the presentations from the workshop are included

  20. Design and fabrication of biomimetic multiphased scaffolds for ligament-to-bone fixation.

    Science.gov (United States)

    He, Jiankang; Zhang, Wenyou; Liu, Yaxiong; Li, Xiang; Li, Dichen; Jin, Zhongmin

    2015-05-01

    Conventional ligament grafts with single material composition cannot effectively integrate with the host bones due to mismatched properties and eventually affect their long-term function in vivo. Here we presented a multi-material strategy to design and fabricate composite scaffolds including ligament, interface and bone multiphased regions. The interface region consists of triphasic layers with varying material composition and porous structure to mimic native ligament-to-bone interface while the bone region contains polycaprolactone (PCL) anchor and microchanneled ceramic scaffolds to potentially provide combined mechanical and biological implant-bone fixation. Finite element analysis (FEA) demonstrated that the multiphased scaffolds with interference value smaller than 0.5 mm could avoid the fracture of ceramic scaffold during the implantation process, which was validated by in-vitro implanting the multiphased scaffolds into porcine joint bones. Pull-out experiment showed that the initial fixation between the multiphased scaffolds with 0.47 mm interference and the host bones could withstand the maximum force of 360.31±97.51 N, which can be improved by reinforcing the ceramic scaffolds with biopolymers. It is envisioned that the multiphased scaffold could potentially induce the regeneration of a new bone as well as interfacial tissue with the gradual degradation of the scaffold and subsequently realize long-term biological fixation of the implant with the host bone. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Calculation model of non-linear dynamic deformation of composite multiphase rods

    Directory of Open Access Journals (Sweden)

    Mishchenko Andrey Viktorovich

    2014-05-01

    Full Text Available The method of formulating non-linear physical equations for multiphase rods is suggested in the article. Composite multiphase rods possess various structures, include shear, polar, radial and axial inhomogeneity. The Timoshenko’s hypothesis with the large rotation angles is used. The method is based on the approximation of longitudinal normal stress low by basic functions expansions regarding the linear viscosity low. The shear stresses are calculated with the equilibrium equation using the subsidiary function of the longitudinal shift force. The system of differential equations connecting the internal forces and temperature with abstract deformations are offered by the basic functions. The application of power functions with arbitrary index allows presenting the compact form equations. The functional coefficients in this system are the highest order rigidity characteristics. The whole multiphase cross-section rigidity characteristics are offered the sums of the rigidity characteristics of the same phases individually. The obtained system allows formulating the well-known particular cases. Among them: hard plasticity and linear elastic deformation, different module deformation and quadratic Gerstner’s low elastic deformation. The reform of differential equations system to the quasilinear is suggested. This system contains the secant variable rigidity characteristics depending on abstract deformations. This system includes the sum of the same uniform blocks of different order. The rods phases defined the various set of uniform blocks phase materials. The integration of dynamic, kinematic and physical equations taking into account initial and edge condition defines the full dynamical multiphase rods problem. The quasilinear physical equations allow getting the variable flexibility matrix of multiphase rod and rods system.

  2. A Multi-Phase Equation of State and Strength Model for Tin

    International Nuclear Information System (INIS)

    Cox, G. A.

    2006-01-01

    This paper considers a multi-phase equation of state and a multi-phase strength model for tin in the β, γ and liquid phases. At a phase transition there are changes in volume, energy, and properties of a material that should be included in an accurate model. The strength model will also be affected by a solid-solid phase transition. For many materials there is a lack of experimental data for strength at high pressures making the derivation of strength parameters for some phases difficult. In the case of tin there are longitudinal sound speed data on the Hugoniot available that have been used here in conjunction with a multi-phase equation of state to derive strength parameters for the γ phase, a phase which does not exist at room temperature and pressure

  3. Microleakage comparison of glass-ionomer and white mineral trioxide aggregate used as a coronal barrier in nonvital bleaching.

    Science.gov (United States)

    Vosoughhosseini, Sepideh; Lotfi, Mehrdad; Shahmoradi, Kaveh; Saghiri, Mohammad-Ali; Zand, Vahid; Mehdipour, Masoumeh; Ranjkesh, Bahram; Mokhtari, Hadi; Salemmilani, Amin; Doosti, Sirvan

    2011-11-01

    There is some evidence that the pH at the root surface is reduced by intracoronal placement of bleaching pastes, which is known to enhance osteoclastic activity. Therefore, it is recommended that a protective barrier be used over the canal filling to prevent leakage of bleaching agents. Glass-ionomer (GI) is commonly used as a coronal barrier before nonvital bleaching. Because mineral trioxide aggregate (MTA) creates high alkalinity after mixing with water, using MTA as a protective barrier over the canal filling may not only prevent leakage of bleaching agents and microorganisms, but may prevent cervical resorption. The aim of this study was to evaluate sealing ability of white mineral trioxide aggregate (WMTA) as a coronal barrier before nonvital bleaching. Root canals of one hundred thirty human maxillary incisors were instrumented and filled with gutta-percha without sealer. Gutta-percha was removed up to 3 mm below the cementoenamel junction (CEJ). The teeth were randomly divided into six experimental groups of 20 teeth each and two control groups of 5. In three experimental groups, WMTA was packed into the canal to the level of CEJ. In the remaining experimental groups, glass-ionomer (GI) was used as a coronal barrier. After a 24-hour incubation period, one of the following three bleaching agents was placed in the access cavity of each of the WMTA or GI groups. These three bleaching agents were 30% hydrogen peroxide, sodium perborate mixed with 30% hydrogen peroxide, and sodium perborate mixed with distilled water. The bleaching agents were replaced every 3 days for three times. In the positive controls, no coronal barrier was used. In the negative controls, all the tooth surfaces were covered by two layers of nail varnish. Microleakage was evaluated using protein leakage test. Statistical analyses were performed with the Kruskal-Wallis and Mann-Whitney tests. The experimental groups showed minimum leakage which was not significantly more than tha in the

  4. Multiphase Microstructure in a Metastability-Assisted Medium Carbon Alloy Steel

    Science.gov (United States)

    Liu, Cheng; Cui, Xixi; Yang, Chen

    2018-05-01

    A medium carbon alloy steel is processed by austenizing at 900 °C for 30 min, then rapid quenching into a patented quenching liquid and holding at 170 °C for 5 min, finally isothermally holding at 250 °C for different times. The morphology and mechanical properties are performed by using optical microscopy and scanning electron microscopy. A multiphase microstructure characterized by a mixture of lenticular prior martensite (PM), fine needle bainitic ferrite and filmy retained austenite (RA) is obtained. It is found that the PM formed firstly upon quenching can accelerate the subsequent bainitic transformation and promote refinement of multiphase colonies. The results show that an optimum mechanical property of a 4000.9 MPa bending strength and a 2030 MPa tensile strength is achieved at 250 °C for 120 min, which is attributed to the multiphase microstructural characteristics and a high product of the volume fraction of RA and the carbon content of austenite.

  5. Variational continuum multiphase poroelasticity theory and applications

    CERN Document Server

    Serpieri, Roberto

    2017-01-01

    This book collects the theoretical derivation of a recently presented general variational macroscopic continuum theory of multiphase poroelasticity (VMTPM), together with its applications to consolidation and stress partitioning problems of interest in several applicative engineering contexts, such as in geomechanics and biomechanics. The theory is derived based on a purely-variational deduction, rooted in the least-Action principle, by considering a minimal set of kinematic descriptors. The treatment herein considered keeps a specific focus on the derivation of most general medium-independent governing equations. It is shown that VMTPM recovers paradigms of consolidated use in multiphase poroelasticity such as Terzaghi's stress partitioning principle and Biot's equations for wave propagation. In particular, the variational treatment permits the derivation of a general medium-independent stress partitioning law, and the proposed variational theory predicts that the external stress, the fluid pressure, and the...

  6. Development and application of a fully implicit fluid dynamics code for multiphase flow

    International Nuclear Information System (INIS)

    Morii, Tadashi; Ogawa, Yumi

    1996-01-01

    Multiphase flow frequently occurs in a progression of accidents of nuclear reactor severe core damage. The CHAMPAGNE code has been developed to analyze thermohydraulic behavior of multiphase and multicomponent fluid, which requires for its characterization more than one set of velocities, temperatures, masses per unit volume, and so forth at each location in the calculation domain. Calculations of multiphase flow often show physical and numerical instability. The effect of numerical stabilization obtained by the upwind differencing and the fully implicit techniques gives one a convergent solution more easily than other techniques. Several results calculated by the CHAMPAGNE code are explained

  7. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    Science.gov (United States)

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  8. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    Directory of Open Access Journals (Sweden)

    Ahmed Alkahtani

    2013-01-01

    Full Text Available The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  9. Threading the Needle: Intrapelvic Displacement of a Femoral Neck Fracture through the Obturator Foramen

    Directory of Open Access Journals (Sweden)

    Gautham Prabhakar

    2018-01-01

    Full Text Available Despite timely and appropriate management, displaced femoral neck fractures are often devastating injuries for the young patient. The risk of negative sequelae is further amplified with increasing displacement and vertical fracture patterns. Open anatomic reduction with rigid internal fixation is essential to maximize the healing potential in displaced fractures of the femoral neck. Successful primary osteosynthesis of significantly displaced femoral neck fractures in the young patient has been reported in the literature. We present a unique case of open reduction and internal fixation of a high-energy femoral neck fracture with extrusion of the head through the obturator foramen into the pelvis without associated acetabular or pelvic injury.

  10. The multiphase physics of sea ice: a review for model developers

    Directory of Open Access Journals (Sweden)

    E. C. Hunke

    2011-11-01

    Full Text Available Rather than being solid throughout, sea ice contains liquid brine inclusions, solid salts, microalgae, trace elements, gases, and other impurities which all exist in the interstices of a porous, solid ice matrix. This multiphase structure of sea ice arises from the fact that the salt that exists in seawater cannot be incorporated into lattice sites in the pure ice component of sea ice, but remains in liquid solution. Depending on the ice permeability (determined by temperature, salinity and gas content, this brine can drain from the ice, taking other sea ice constituents with it. Thus, sea ice salinity and microstructure are tightly interconnected and play a significant role in polar ecosystems and climate. As large-scale climate modeling efforts move toward "earth system" simulations that include biological and chemical cycles, renewed interest in the multiphase physics of sea ice has strengthened research initiatives to observe, understand and model this complex system. This review article provides an overview of these efforts, highlighting known difficulties and requisite observations for further progress in the field. We focus on mushy layer theory, which describes general multiphase materials, and on numerical approaches now being explored to model the multiphase evolution of sea ice and its interaction with chemical, biological and climate systems.

  11. Effect of a calcium hydroxide-based root canal dressing on periapical repair in dogs: a histological study.

    Science.gov (United States)

    Leonardo, Mario R; Hernandez, Maria E F T; Silva, Léa A B; Tanomaru-Filho, Mário

    2006-11-01

    To compare the periapical repair of teeth with periapical lesion following root canal treatment by using a calcium hydroxide-based intracanal dressing for several time periods or filling in a single visit. After induction of periapical lesions in 4 dogs, the root canals were prepared using 5.25% sodium hypochlorite for irrigation, and animals were separated into 4 experimental groups; in group I, root canals were filled in a single session; in groups II, III, and IV, a calcium hydroxide-based dressing was kept in place for 15, 30, or 180 days, respectively. Root canals from groups I, II, and III were filled with gutta-percha cones and AH Plus sealer. After 180 days, animals were killed and histological sections were stained with hematoxylin-eosin to evaluate periapical repair. Periapical repair was better in groups II, III, and IV (intracanal dressing) compared with group I (single session; P session treatment.

  12. Multiphase flow measurement in the slug regime using ultrasonic measurement techniques and slug closure model

    OpenAIRE

    Al-lababidi , Salem

    2006-01-01

    Multiphase flow in the oil and gas industry covers a wide range of flows. Thus, over the last decade, the investigation, development and use of multiphase flow metering system have been a major focus for the industry worldwide. However, these meters do not perform well in slug flow conditions. The present work involves experimental investigations of multiphase flow measurement under slug flow conditions. A two-phase gas/liquid facility was designed and constructed at Cranfie...

  13. High-Voltage, Multiphasic, Nanosecond Pulses to Modulate Cellular Responses.

    Science.gov (United States)

    Ryan, Hollie A; Hirakawa, Shinji; Yang, Enbo; Zhou, Chunrong; Xiao, Shu

    2018-04-01

    Nanosecond electric pulses are an effective power source in plasma medicine and biological stimulation, in which biophysical responses are governed by peak power and not energy. While uniphasic nanosecond pulse generators are widely available, the recent discovery that biological effects can be uniquely modulated by reversing the polarity of nanosecond duration pulses calls for the development of a multimodal pulse generator. This paper describes a method to generate nanosecond multiphasic pulses for biomedical use, and specifically demonstrates its ability to cancel or enhance cell swelling and blebbing. The generator consists of a series of the fundamental module, which includes a capacitor and a MOSFET switch. A positive or a negative phase pulse module can be produced based on how the switch is connected. Stacking the modules in series can increase the voltage up to 5 kV. Multiple stacks in parallel can create multiphase outputs. As each stack is independently controlled and charged, multiphasic pulses can be created to produce flexible and versatile pulse waveforms. The circuit topology can be used for high-frequency uniphasic or biphasic nanosecond burst pulse production, creating numerous opportunities for the generator in electroporation applications, tissue ablation, wound healing, and nonthermal plasma generation.

  14. Investigation of free vibration characteristics for skew multiphase magneto-electro-elastic plate

    Science.gov (United States)

    Kiran, M. C.; Kattimani, S.

    2018-04-01

    This article presents the investigation of skew multiphase magneto-electro-elastic (MMEE) plate to assess its free vibration characteristics. A finite element (FE) model is formulated considering the different couplings involved via coupled constitutive equations. The transformation matrices are derived to transform local degrees of freedom into the global degrees of freedom for the nodes lying on the skew edges. Effect of different volume fraction (Vf) on the free vibration behavior is explicitly studied. In addition, influence of width to thickness ratio, the aspect ratio, and the stacking arrangement on natural frequencies of skew multiphase MEE plate investigated. Particular attention has been paid to investigate the effect of skew angle on the non-dimensional Eigen frequencies of multiphase MEE plate with simply supported edges.

  15. Applied multiphase flow in pipes and flow assurance oil and gas production

    CERN Document Server

    Al-Safran, Eissa M

    2017-01-01

    Applied Multiphase Flow in Pipes and Flow Assurance - Oil and Gas Production delivers the most recent advancements in multiphase flow technology while remaining easy to read and appropriate for undergraduate and graduate petroleum engineering students. Responding to the need for a more up-to-the-minute resource, this highly anticipated new book represents applications on the fundamentals with new material on heat transfer in production systems, flow assurance, transient multiphase flow in pipes and the TUFFP unified model. The complex computation procedure of mechanistic models is simplified through solution flowcharts and several example problems. Containing over 50 solved example problems and 140 homework problems, this new book will equip engineers with the skills necessary to use the latest steady-state simulators available.

  16. Recent developments in biocatalysis in multiphasic ionic liquid reaction systems.

    Science.gov (United States)

    Meyer, Lars-Erik; von Langermann, Jan; Kragl, Udo

    2018-06-01

    Ionic liquids are well known and frequently used 'designer solvents' for biocatalytic reactions. This review highlights recent achievements in the field of multiphasic ionic liquid-based reaction concepts. It covers classical biphasic systems including supported ionic liquid phases, thermo-regulated multi-component solvent systems (TMS) and polymerized ionic liquids. These powerful concepts combine unique reaction conditions with a high potential for future applications on a laboratory and industrial scale. The presence of a multiphasic system simplifies downstream processing due to the distribution of the catalyst and reactants in different phases.

  17. Visualization of multiphase flow by neutron radiography

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Takenaka, Nobuyuki.

    1991-01-01

    Neutron radiography (NRG) is a technique which produces images of the internal structure of a body, making use of the attenuation characteristics of neutrons in the materials being observed. Recently, attempts have been made to expand the application of this technique not only to non-destructive testing but also to a variety of industrial and basic research fields. The attenuation of neutrons is large in a light material like water and small in ordinary metals, which difference may make it possible to visualize a multiphase flow in a metallic container. Particularly, the neutron television, which is one of the applied techniques of NRG, is expected to be a useful tool for observing the behavior of two-phase flow, since it produces images in real time. In this paper the basic idea and the method of NRG are presented along with examples of visualization of multiphase flow by NRG. (author)

  18. Parametric Study on the Characteristics of Multiphase Laminar Flow with Density Difference in Various Microchannels

    International Nuclear Information System (INIS)

    Paek, Seung Ho; Kim, Dong Sung; Choi, Young Ki

    2009-01-01

    In this paper, we have performed a parametric study on the characteristics of multiphase laminar flow with density difference in various microchannels. The interface between multiphase fluids is rotated by the gravitational forces induced by density difference. The numerical simulations were carried out via commercial CFD package to study the characteristics of multiphase laminar flow. The results of the numerical simulations in this study were verified by comparing with the previously reported experimental results in the literature. We have also proposed a new dimensionless relationship between dimensionless rotation angle of interface and dimensionless parameters are proposed for square microchannels with various aspect ratios. The dimensionless relationship could be widely applied to the reliable design of various microfluidic devices dealing with multiphase laminar flow

  19. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator.

    Science.gov (United States)

    Michelinakis, George

    2017-01-01

    This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  20. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator

    Directory of Open Access Journals (Sweden)

    George Michelinakis

    2017-01-01

    Full Text Available This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  1. Multi-phase flow monitoring with electrical impedance tomography using level set based method

    International Nuclear Information System (INIS)

    Liu, Dong; Khambampati, Anil Kumar; Kim, Sin; Kim, Kyung Youn

    2015-01-01

    Highlights: • LSM has been used for shape reconstruction to monitor multi-phase flow using EIT. • Multi-phase level set model for conductivity is represented by two level set functions. • LSM handles topological merging and breaking naturally during evolution process. • To reduce the computational time, a narrowband technique was applied. • Use of narrowband and optimization approach results in efficient and fast method. - Abstract: In this paper, a level set-based reconstruction scheme is applied to multi-phase flow monitoring using electrical impedance tomography (EIT). The proposed scheme involves applying a narrowband level set method to solve the inverse problem of finding the interface between the regions having different conductivity values. The multi-phase level set model for the conductivity distribution inside the domain is represented by two level set functions. The key principle of the level set-based method is to implicitly represent the shape of interface as the zero level set of higher dimensional function and then solve a set of partial differential equations. The level set-based scheme handles topological merging and breaking naturally during the evolution process. It also offers several advantages compared to traditional pixel-based approach. Level set-based method for multi-phase flow is tested with numerical and experimental data. It is found that level set-based method has better reconstruction performance when compared to pixel-based method

  2. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  3. RAND-Based Formulations for Isothermal Multiphase Flash

    DEFF Research Database (Denmark)

    Paterson, Duncan; Michelsen, Michael L.; Stenby, Erling H.

    2018-01-01

    Two algorithms are proposed for isothermal multiphase flash. These are referred to as modified RAND and vol-RAND. The former uses the chemical potentials and molar-phase amounts as the iteration variables, while the latter uses chemical potentials and phase volumes to cosolve a pressure...

  4. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis.

    Science.gov (United States)

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis; Torres-Lagares, Daniel

    2017-08-01

    Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the "Virgen del Rocío" University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation. The POP has a greater use, as long as the defect in the

  5. Advancement and Application of Multi-Phase CFD Modeling to High Speed Supercavitating Flows

    Science.gov (United States)

    2013-08-13

    October 2008 - December 2013 4. TITLE AND SUBTITLE Advancement and Application of Multi-Phase CFD Modeling to High Speed Supercavitating Flows...influence cavity hysteresis behavior. These observations are used to guide improved supercavitating -vehicle analyses including numerical predictions...experiments, and modeling 15. SUBJECT TERMS supercavitation , computational fluid dynamics, multiphase flow 16. SECURITY CLASSIFICATION OF: a

  6. Multiphase flow in porous media using CFD

    DEFF Research Database (Denmark)

    Hemmingsen, Casper Schytte; Walther, Jens Honore

    . This approach is widely used for single phase flow, but not for multiphase flow in porous media. This might be due to the complexity of introducing relative permeability and capillary pressure in the CFD solver.The introduction of relative permeability and capillary pressure may cause numerical instabilities...

  7. A Radiative Transfer Modeling Methodology in Gas-Liquid Multiphase Flow Simulations

    Directory of Open Access Journals (Sweden)

    Gautham Krishnamoorthy

    2014-01-01

    Full Text Available A methodology for performing radiative transfer calculations in computational fluid dynamic simulations of gas-liquid multiphase flows is presented. By considering an externally irradiated bubble column photoreactor as our model system, the bubble scattering coefficients were determined through add-on functions by employing as inputs the bubble volume fractions, number densities, and the fractional contribution of each bubble size to the bubble volume from four different multiphase modeling options. The scattering coefficient profiles resulting from the models were significantly different from one another and aligned closely with their predicted gas-phase volume fraction distributions. The impacts of the multiphase modeling option, initial bubble diameter, and gas flow rates on the radiation distribution patterns within the reactor were also examined. An increase in air inlet velocities resulted in an increase in the fraction of larger sized bubbles and their contribution to the scattering coefficient. However, the initial bubble sizes were found to have the strongest impact on the radiation field.

  8. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  9. Analysis of Voltage Forming Methods for Multiphase Inverters

    Directory of Open Access Journals (Sweden)

    Tadas Lipinskis

    2013-05-01

    Full Text Available The article discusses advantages of the multiphase AC induction motor over three or less phase motors. It presents possible stator winding configurations for a multiphase induction motor. Various fault control strategies were reviewed for phases feeding the motor. The authors propose a method for quality evaluation of voltage forming algorithm in the inverter. Simulation of a six-phase voltage source inverter, voltage in which is formed using a simple SPWM control algorithm, was performed in Matlab Simulink. Simulation results were evaluated using the proposed method. Inverter’s power stage was powered by 400 V DC source. The spectrum of output currents was analysed and the magnitude of the main frequency component was at least 12 times greater than the next biggest-magnitude component. The value of rectified inverter voltage was 373 V.Article in Lithuanian

  10. Multiphase averaging of periodic soliton equations

    International Nuclear Information System (INIS)

    Forest, M.G.

    1979-01-01

    The multiphase averaging of periodic soliton equations is considered. Particular attention is given to the periodic sine-Gordon and Korteweg-deVries (KdV) equations. The periodic sine-Gordon equation and its associated inverse spectral theory are analyzed, including a discussion of the spectral representations of exact, N-phase sine-Gordon solutions. The emphasis is on physical characteristics of the periodic waves, with a motivation from the well-known whole-line solitons. A canonical Hamiltonian approach for the modulational theory of N-phase waves is prescribed. A concrete illustration of this averaging method is provided with the periodic sine-Gordon equation; explicit averaging results are given only for the N = 1 case, laying a foundation for a more thorough treatment of the general N-phase problem. For the KdV equation, very general results are given for multiphase averaging of the N-phase waves. The single-phase results of Whitham are extended to general N phases, and more importantly, an invariant representation in terms of Abelian differentials on a Riemann surface is provided. Several consequences of this invariant representation are deduced, including strong evidence for the Hamiltonian structure of N-phase modulational equations

  11. Online recognition of the multiphase flow regime and study of slug flow in pipeline

    International Nuclear Information System (INIS)

    Guo Liejin; Bai Bofeng; Zhao Liang; Wang Xin; Gu Hanyang

    2009-01-01

    Multiphase flow is the phenomenon existing widely in nature, daily life, as well as petroleum and chemical engineering industrial fields. The interface structure among multiphase and their movement are complicated, which distribute random and heterogeneously in the spatial and temporal scales and have multivalue of the flow structure and state. Flow regime is defined as the macro feature about the multiphase interface structure and its distribution, which is an important feature to describe multiphase flow. The energy and mass transport mechanism differ much for each flow regimes. It is necessary to solve the flow regime recognition to get a clear understanding of the physical phenomena and their mechanism of multiphase flow. And the flow regime is one of the main factors affecting the online measurement accuracy of phase fraction, flow rate and other phase parameters. Therefore, it is of great scientific and technological importance to develop new principles and methods of multiphase flow regime online recognition, and of great industrial background. In this paper, the key reasons that the present method cannot be used to solve the industrial multiphase flow pattern recognition are clarified firstly. Then the prerequisite to realize the online recognition of multiphase flow regime is analyzed, and the recognition rules for partial flow pattern are obtained based on the massive experimental data. The standard templates for every flow regime feature are calculated with self-organization cluster algorithm. The multi-sensor data fusion method is proposed to realize the online recognition of multiphase flow regime with the pressure and differential pressure signals, which overcomes the severe influence of fluid flow velocity and the oil fraction on the recognition. The online recognition method is tested in the practice, which has less than 10 percent measurement error. The method takes advantages of high confidence, good fault tolerance and less requirement of single

  12. Computational Flow Modeling of Hydrodynamics in Multiphase Trickle-Bed Reactors

    Science.gov (United States)

    Lopes, Rodrigo J. G.; Quinta-Ferreira, Rosa M.

    2008-05-01

    This study aims to incorporate most recent multiphase models in order to investigate the hydrodynamic behavior of a TBR in terms of pressure drop and liquid holdup. Taking into account transport phenomena such as mass and heat transfer, an Eulerian k-fluid model was developed resulting from the volume averaging of the continuity and momentum equations and solved for a 3D representation of the catalytic bed. Computational fluid dynamics (CFD) model predicts hydrodynamic parameters quite well if good closures for fluid/fluid and fluid/particle interactions are incorporated in the multiphase model. Moreover, catalytic performance is investigated with the catalytic wet oxidation of a phenolic pollutant.

  13. Efficiency Improvement of a High Dynamic BLDC Linear Motor by Multiphase Control

    OpenAIRE

    Lemmens, Joris; Vanvlasselaer, Kris; Mulier, Kristof; Goossens, Stijn; Symens, Wim; Driesen, Johan

    2013-01-01

    This paper proposes a multiphase control strategy for a high dynamic brushless DC linear motor as an alternative for conventional three-phase field-oriented control. Analysis of the magnetic field waveforms shows that three-phase control is not optimal for the 6-slot 7-pole motor topology. Therefore, a multiphase control strategy is elaborated which injects currents proportional to the electromotive force into each of the nine stator coil groups. This results in a maximal alignment force ...

  14. Modelling and simulation of multi-phase effects on X-ray elasticity constants

    CERN Document Server

    Freour, S; Guillen, R; François, M X

    2003-01-01

    This paper deals with the calculation of X-ray Elasticity Constants (XEC) of phases embedded in multi-phase polycrystals. A three scales (macroscopic, pseudo-macroscopic, mesoscopic) model based on the classical self-consistent formalism is developed in order to analyse multi-phase effects on XEC values. Simulations are performed for cubic or hexagonal crystallographic structure phases embedded in several two-phases materials. In fact, it is demonstrated that XEC vary with the macroscopic stiffness of the whole polycrystal. In consequence, the constants of one particular phase depend on the elastic behaviour and the volume fraction of all the phases constituting the material. Now, XEC play a leading role in pseudo-macroscopic stresses determination by X-Ray Diffraction (XRD) methods. In this work, a quantitative analysis of the multi-phase effects on stresses determination by XRD methods was performed. Numerical results will be compared and discussed. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  15. Performance analysis of variable speed multiphase induction motor with pole phase modulation

    Directory of Open Access Journals (Sweden)

    Liu Huijuan

    2016-09-01

    Full Text Available The pole phase modulation (PPM technique is an effective method to extend speed range and torque capabilities for an integrated starter and hybrid electric vehicles applications. In this paper, the five pole-phase combination types of a multiphase induction motor (IM with 36 stator slots and 36 stator conductors are presented and compared quantitatively by using the time-stepping finite element method (TS-FEM. The 36 stator conductors of the proposed multiphase IM are fed by a 36 leg inverter and the current phase angle and amplitude of each stator conductor can be controlled independently. This paper focuses on the winding connection, the PPM technique and the performance comparative analysis of each pole-phase combination types of the proposed multiphase IM. The flux distribution, air-gap flux density, output torque, core losses and efficiency of five pole-phase combination types have been investigated.

  16. Multiphase flow parameter estimation based on laser scattering

    Science.gov (United States)

    Vendruscolo, Tiago P.; Fischer, Robert; Martelli, Cicero; Rodrigues, Rômulo L. P.; Morales, Rigoberto E. M.; da Silva, Marco J.

    2015-07-01

    The flow of multiple constituents inside a pipe or vessel, known as multiphase flow, is commonly found in many industry branches. The measurement of the individual flow rates in such flow is still a challenge, which usually requires a combination of several sensor types. However, in many applications, especially in industrial process control, it is not necessary to know the absolute flow rate of the respective phases, but rather to continuously monitor flow conditions in order to quickly detect deviations from the desired parameters. Here we show how a simple and low-cost sensor design can achieve this, by using machine-learning techniques to distinguishing the characteristic patterns of oblique laser light scattered at the phase interfaces. The sensor is capable of estimating individual phase fluxes (as well as their changes) in multiphase flows and may be applied to safety applications due to its quick response time.

  17. Multiphase flow parameter estimation based on laser scattering

    International Nuclear Information System (INIS)

    Vendruscolo, Tiago P; Fischer, Robert; Martelli, Cicero; Da Silva, Marco J; Rodrigues, Rômulo L P; Morales, Rigoberto E M

    2015-01-01

    The flow of multiple constituents inside a pipe or vessel, known as multiphase flow, is commonly found in many industry branches. The measurement of the individual flow rates in such flow is still a challenge, which usually requires a combination of several sensor types. However, in many applications, especially in industrial process control, it is not necessary to know the absolute flow rate of the respective phases, but rather to continuously monitor flow conditions in order to quickly detect deviations from the desired parameters. Here we show how a simple and low-cost sensor design can achieve this, by using machine-learning techniques to distinguishing the characteristic patterns of oblique laser light scattered at the phase interfaces. The sensor is capable of estimating individual phase fluxes (as well as their changes) in multiphase flows and may be applied to safety applications due to its quick response time. (paper)

  18. Multiphase Nanocrystalline Ceramic Concept for Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Mecartnery, Martha [Univ. of California, Irvine, CA (United States); Graeve, Olivia [Univ. of California, San Diego, CA (United States); Patel, Maulik [Univ. of Liverpool (United Kingdom)

    2017-05-25

    The goal of this research is to help develop new fuels for higher efficiency, longer lifetimes (higher burn-up) and increased accident tolerance in future nuclear reactors. Multiphase nanocrystalline ceramics will be used in the design of simulated advanced inert matrix nuclear fuel to provide for enhanced plasticity, better radiation tolerance, and improved thermal conductivity

  19. Multiphase Nanocrystalline Ceramic Concept for Nuclear Fuel

    International Nuclear Information System (INIS)

    Mecartnery, Martha; Graeve, Olivia; Patel, Maulik

    2017-01-01

    The goal of this research is to help develop new fuels for higher efficiency, longer lifetimes (higher burn-up) and increased accident tolerance in future nuclear reactors. Multiphase nanocrystalline ceramics will be used in the design of simulated advanced inert matrix nuclear fuel to provide for enhanced plasticity, better radiation tolerance, and improved thermal conductivity

  20. A multiphase series-resonant converter with a new topology and a reduced number of thyristors

    NARCIS (Netherlands)

    Huisman, H.

    1995-01-01

    Multiphase series resonant (SR) power converters provide a flexible way to transform power between a utility grid and a multiphase load or source. The current implementations all suffer from a high component count, which makes the use of these power converters unattractive from an economical point

  1. Noninvasive tomographic and velocimetric monitoring of multiphase flows

    International Nuclear Information System (INIS)

    Chaouki, J.; Dudukovic, M.P.

    1997-01-01

    A condensed review of recent advances accomplished in the development and the applications of noninvasive tomographic and velocimetric measurement techniques to multiphase flows and systems is presented. In recent years utilization of such noninvasive techniques has become widespread in many engineering disciplines that deal with systems involving two immiscible phases or more. Tomography provides concentration, holdup, or 2D or 3D density distribution of at least one component of the multiphase system, whereas velocimetry provides the dynamic features of the phase of interest such as the flow pattern, the velocity field, the 2D or 3D instantaneous movements, etc. The following review is divided into two parts. The first part summarizes progress and developments in flow imaging techniques using γ-ray and X-ray transmission tomography; X-ray radiography; neutron transmission tomography and radiography; positron emission tomography; X-ray diffraction tomography; nuclear magnetic resonance imaging; electrical capacitance tomography; optical tomography; microwave tomography; and ultrasonic tomography. The second part of the review summarizes progress and developments in the following velocimetry techniques: positron emission particle tracking; radioactive particle tracking; cinematography; laser-Doppler anemometry; particle image velocimetry; and fluorescence particle image velocimetry. The basic principles of tomography and velocimetry techniques are outlined, along with advantages and limitations inherent to each technique. The hydrodynamic and structural information yielded by these techniques is illustrated through a literature survey on their successful applications to the study of multiphase systems in such fields as particulate solids processes, fluidization engineering, porous media, pipe flows, transport within packed beds and sparged reactors, etc

  2. Problems of multiphase fluid filtration

    CERN Document Server

    Konovalov, AN

    1994-01-01

    This book deals with a spectrum of problems related to the mathematical modeling of multiphase filtration. Emphasis is placed on an inseparable triad: model - algorithm - computer code. An analysis of new and traditional filtration problems from the point of view of both their numerical implementation and the reproduction of one or another technological characteristics of the processes under consideration is given. The basic principles which underlie the construction of efficient numerical methods taking into account the filtration problems are discussed: non-evolutionary nature, degeneration,

  3. Multiphase Flow Dynamics 4 Turbulence, Gas Adsorption and Release, Diesel Fuel Properties

    CERN Document Server

    Kolev, Nikolay Ivanov

    2012-01-01

    The present Volume 4 of the successful monograh package “Multiphase Flow Dynamics”is devoted to selected Chapters of the multiphase fluid dynamics that are important for practical applications but did not find place in the previous volumes. The state of the art of the turbulence modeling in multiphase flows is presented. As introduction, some basics of the single phase boundary layer theory including some important scales and flow oscillation characteristics in pipes and rod bundles are presented. Then the scales characterizing the dispersed flow systems are presented. The description of the turbulence is provided at different level of complexity: simple algebraic models for eddy viscosity, simple algebraic models based on the Boussinesq hypothesis, modification of the boundary layer share due to modification of the bulk turbulence, modification of the boundary layer share due to nucleate boiling. The role of the following forces on the mathematical description of turbulent flows is discussed: the lift fo...

  4. Analysis of multiphase flows using dual-energy gamma densitometry and neural networks

    International Nuclear Information System (INIS)

    Bishop, C.M.; James, G.D.

    1993-01-01

    Dual-energy gamma densitometry offers a powerful technique for the non-intrusive analysis of multiphase flows. By employing multiple beam lines, information on the phase configuration can be obtained. Once the configuration is known, it then becomes possible in principle to determine the phase fractions. In practice, however, the extraction of the phase fractions from the densitometer data is complicated by the wide variety of phase configurations which can arise, and by the considerable difficulties of modelling multiphase flows. In this paper we show that neural network techniques provide a powerful approach to the analysis of data from dual-energy gamma densitometers, allowing both the phase configuration and the phase fractions to be determined with high accuracy, whilst avoiding the uncertainties associated with modelling. The technique is well suited to the determination of oil, water and gas fractions in multiphase oil pipelines. Results from linear and non-linear network models are compared, and a new technique for validating the network output is described. (orig.)

  5. A multiphase electrokinetic flow model for electrolytes with liquid/liquid interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Berry, J.D., E-mail: joe.d.berry@gmail.com; Davidson, M.R., E-mail: m.davidson@unimelb.edu.au; Harvie, D.J.E., E-mail: daltonh@unimelb.edu.au

    2013-10-15

    A numerical model for electrokinetic flow of multiphase systems with deformable interfaces is presented, based on a combined level set-volume of fluid technique. A new feature is a multiphase formulation of the Nernst–Planck transport equation for advection, diffusion and conduction of individual charge carrier species that ensures their conservation in each fluid phase. The numerical model is validated against the analytical results of Zholkovskij et al. (2002) [1], and results for the problem of two drops coalescing in the presence of mobile charge carriers are presented. The time taken for two drops containing ions to coalesce decreases with increasing ion concentration.

  6. Interim obturator in an infant with Treacher Collins syndrome: Review and chairside modification in impression making

    Directory of Open Access Journals (Sweden)

    Sudhir Bhandari

    2011-01-01

    Full Text Available Treacher Collins syndrome has been described as a syndrome involving 1st and 2nd branchial arches, affecting various organs in the craniofacial region. Affected infants report with nasal regurgitation and minimal dietary intake due to cleft palate, consequently show delayed and retarded growth. The situation is further complicated when the repair of the palatal defect is postponed due to delayed milestones. At this juncture, it is of paramount importance to intervene prosthetically and close the defect with the aid of an interim obturator. Herein we describe a simple, yet successful, chairside approach to make an impression of an infant without the aid of any kind of anesthesia.

  7. Plant-mediated green synthesis of ZnO nanoparticles using Garcinia gummi-gutta seed extract: Photoluminescence, screening of their catalytic activity in antioxidant, formylation and biodiesel production

    Science.gov (United States)

    Raghavendra, M.; Yatish, K. V.; Lalithamba, H. S.

    2017-08-01

    The green synthesis of multifunctional ZnO nanoparticles (NPs) was prepared by treatment of zinc nitrate with an extract of Garcinia gummi-gutta seed by the combustion method. The ZnO NPs were characterized by XRD, scanning electron microscopy, UV-visible, FTIR spectroscopic techniques. The prepared ZnO NPs were evaluated for photoluminescence (PL), antioxidant properties and also utilized as a catalyst for the formylation of aromatic amines and biodiesel production. The study reveals that the reaction is simple, mild and environmental friendly. Furthermore, the reaction results in excellent yield of products.

  8. Multi-phase alternative current machine winding design | Khan ...

    African Journals Online (AJOL)

    ... single-phase to 18-phase excitation. Experimental results of a five-phase induction machine supplied from a static five-phase supply are provided to support the proposed design. Keywords: AC machine, Multi-phase machine, Stator winding, Five-phase. International Journal of Engineering, Science and Technology, Vol.

  9. Seeking simplicity for the understanding of multiphase flows

    Science.gov (United States)

    Stone, Howard A.

    2017-10-01

    Fluid mechanics is a discipline with rich phenomena, with motions occurring over an enormous range of length scales, and spanning a wide range of laminar and turbulent flows, instabilities, and applications in industry, nature, biology, and medicine. The subfield of complex fluids typically refers to those flows where the complexity is introduced, for example, by the presence of suspended particles, multiple phases, soft boundaries, and electrokinetic effects; several distinct multiphase flows of Newtonian fluids make up the examples in this article. Interfaces play a significant role and modify the flow with feedback that further changes the shapes of the interfaces. I will provide examples of our work highlighting (i) new features of classical instabilities triggered by changes in geometry, (ii) multiphase flows relevant to the design of liquid-infused substrates exhibiting effective slip while retaining the trapped liquid, and (iii) unexpected dynamics in flow at a T-junction. The interplay of experiments and mathematical models and/or simulations is critical to the new understanding developed.

  10. Multiphase region of helimagnetic superlattices at low temperature in an extended six-state clock model

    Science.gov (United States)

    Lovelady, D. C.; Harper, H. M.; Brodsky, I. E.; Rabson, D. A.

    2006-05-01

    The variety of magnetic phases observed in rare-earth heterostructures at low temperatures (Jehan et al 1993 Phys. Rev. B 48 5594-606), such as Ho/Y, may be elucidated by an ANNNI-like model Hamiltonian. In previous work modelling bulk Ho (Seno, Rabson and Yeomans 1993 J. Phys. A: Math. Gen. 26 4887-905), such a Hamiltonian with a one-dimensional parameter space produced a single multiphase point. In contrast, the parameter space of the heterostructure model is three dimensional, and instead of an isolated multiphase point, we find two-dimensional multiphase regions. In an example of Villain's 'order from disorder' (Villain, Bidaux, Carton and Conte 1980 J. Physique 41 1263-72 Pimpinelli, Uimin and Villain 1991 J. Phys.: Condens. Matter 3 4693-719), an infinitesimal temperature breaks the ground-state degeneracy. In first order of a low-temperature expansion, we find that the degeneracy is broken everywhere in a multiphase region except on a line. A segment of the line appears to remain multiphase to all orders in a low-temperature expansion when the number L of magnetic layers between non-magnetic spacers is 4 but not for other values of L. For L = 4, the hierarchy of phases more closely resembles that in the ANNNI model than in the bulk six-state clock model on which the present model is based.

  11. Multiphase region of helimagnetic superlattices at low temperature in an extended six-state clock model

    International Nuclear Information System (INIS)

    Lovelady, D C; Harper, H M; Brodsky, I E; Rabson, D A

    2006-01-01

    The variety of magnetic phases observed in rare-earth heterostructures at low temperatures (Jehan et al 1993 Phys. Rev. B 48 5594-606), such as Ho/Y, may be elucidated by an ANNNI-like model Hamiltonian. In previous work modelling bulk Ho (Seno, Rabson and Yeomans 1993 J. Phys. A: Math. Gen. 26 4887-905), such a Hamiltonian with a one-dimensional parameter space produced a single multiphase point. In contrast, the parameter space of the heterostructure model is three dimensional, and instead of an isolated multiphase point, we find two-dimensional multiphase regions. In an example of Villain's 'order from disorder' (Villain, Bidaux, Carton and Conte 1980 J. Physique 41 1263-72; Pimpinelli, Uimin and Villain 1991 J. Phys.: Condens. Matter 3 4693-719), an infinitesimal temperature breaks the ground-state degeneracy. In first order of a low-temperature expansion, we find that the degeneracy is broken everywhere in a multiphase region except on a line. A segment of the line appears to remain multiphase to all orders in a low-temperature expansion when the number L of magnetic layers between non-magnetic spacers is 4 but not for other values of L. For L = 4, the hierarchy of phases more closely resembles that in the ANNNI model than in the bulk six-state clock model on which the present model is based

  12. Comparison of Radicular Peroxide Leakage from four Commonly used Bleaching agents following Intracoronal Bleaching in Endodontically treated teeth - An In Vitro Study.

    Science.gov (United States)

    Madhu, Ks; Hegde, Swaroop; Mathew, Sylvia; Lata, DA; Bhandi, Shilpa H; N, Shruthi

    2013-08-01

    Non vital bleaching is simple, conservative procedure for esthetic correction of discolored endodontically treated teeth. The aim of this study was to determine and compare the amount of peroxide leakage from four different bleaching agents i.e superoxol, sodium perborate, combination of superoxol & sodium perborate and carbamide peroxide during intracoronal bleaching, as the safe and effective bleaching is the need of the hour. 50 extracted maxillary centrals were selected for the study. Following standardized protocol access, cleaning and shaping by step back technique and obturation was done using guttapercha and AH plus sealer. Access was sealed with Cavit G and outer root surface was coated with wax and nail varnish. The teeth were separated into crown and root and the root portion was placed in plastic tube containing distilled water for 7days.After incubation, 3mm of gutta-percha was removed below CEJ and 2mm glass ionomer cement base was placed. Grouped into five categories based on the bleaching agent placed in pulp chamber as -group1 (control)-distilled water, group 2-sodium perborate with distilled water , group 3- 30% hydrogen peroxide ,group 4-mixture of sodium perborate and 30% hydrogen peroxide and group 5-10% carbamide peroxide gel. Peroxide leakage was measured after 24hrs using ferrothiocyanate method and optical density using spectrophotometer. Statistical analysis of the data was conducted using ANOVA and multiple comparisons within the groups was done using BONFERRONI method (Post-Hoc tests). The results showed highest peroxide penetration from 30% hydrogen peroxide followed by mixture of sodium perborate with 30% hydrogen peroxide, mixture of sodium perborate with distilled water and least penetration from 10% carbamide peroxide gel. The results were statistically significant. Radicular peroxide leakage in 10% carbamide peroxide was significantly lower than the other tested bleaching agents making it a very safe alternative for intracoronal

  13. Evaluation of the atmospheric significance of multiphase reactions in atmospheric secondary organic aerosol formation

    Directory of Open Access Journals (Sweden)

    Gelencsér

    2005-01-01

    Full Text Available In a simple conceptual cloud-aerosol model the mass of secondary organic aerosol (SOA that may be formed in multiphase reaction in an idealized scenario involving two cloud cycles separated with a cloud-free period is evaluated. The conditions are set to those typical of continental clouds, and each parameter used in the model calculations is selected as a mean of available observational data of individual species for which the multiphase SOA formation route has been established. In the idealized setting gas and aqueous-phase reactions are both considered, but only the latter is expected to yield products of sufficiently low volatility to be retained by aerosol particles after the cloud dissipates. The key variable of the model is the Henry-constant which primarily determines how important multiphase reactions are relative to gas-phase photooxidation processes. The precursor considered in the model is assumed to already have some affinity to water, i.e. it is a compound having oxygen-containing functional group(s. As a principal model output an aerosol yield parameter is calculated for the multiphase SOA formation route as a function of the Henry-constant, and has been found to be significant already above H~103 M atm-1. Among the potential precursors that may be eligible for this mechanism based on their Henry constants, there are a suite of oxygenated compounds such as primary oxidation products of biogenic and anthropogenic hydrocarbons, including, for example, pinonaldehyde. Finally, the analogy of multiphase SOA formation to in-cloud sulfate production is exploited.

  14. A multiphase compressible model for the simulation of multiphase flows

    International Nuclear Information System (INIS)

    Caltagirone, J.P.; Vincent, St.; Caruyer, C.

    2011-01-01

    A compressible model able to manage incompressible two-phase flows as well as compressible motions is proposed. After a presentation of the multiphase compressible concept, the new model and related numerical methods are detailed on fixed structured grids. The presented model is a 1-fluid model with a reformulated mass conservation equation which takes into account the effects of compressibility. The coupling between pressure and flow velocity is ensured by introducing mass conservation terms in the momentum and energy equations. The numerical model is then validated with four test cases involving the compression of an air bubble by water, the liquid injection in a closed cavity filled with air, a bubble subjected to an ultrasound field and finally the oscillations of a deformed air bubble in melted steel. The numerical results are compared with analytical results and convergence orders in space are provided. (authors)

  15. Eulerian Multiphase Population Balance Model of Atomizing, Swirling Flows

    Directory of Open Access Journals (Sweden)

    Narayana P. Rayapati

    2011-06-01

    Full Text Available An Eulerian/Eulerian multiphase flow model coupled with a population balance model is used as the basis for numerical simulation of atomization in swirling flows. The objective of this exercise is to develop a methodology capable of predicting the local point-wise drop size distribution in a spray, such as would be measured by the Phase Doppler Particle Analyzer (PDA. Model predictions are compared to experimental measurements of particle size distributions in an air-blast atomizer spray to demonstrate good qualitative and quantitative agreement. It is observed that the dependence of velocity on drop size inherent in a multiphase description of the drop cloud appears necessary to capture some features of the experimental data. Using this model, we demonstrate the relative contributions of secondary atomization and transport to the variation observed in the downstream spray drop size distribution.

  16. Directional Acoustic Wave Manipulation by a Porpoise via Multiphase Forehead Structure

    Science.gov (United States)

    Zhang, Yu; Song, Zhongchang; Wang, Xianyan; Cao, Wenwu; Au, Whitlow W. L.

    2017-12-01

    Porpoises are small-toothed whales, and they can produce directional acoustic waves to detect and track prey with high resolution and a wide field of view. Their sound-source sizes are rather small in comparison with the wavelength so that beam control should be difficult according to textbook sonar theories. Here, we demonstrate that the multiphase material structure in a porpoise's forehead is the key to manipulating the directional acoustic field. Computed tomography (CT) derives the multiphase (bone-air-tissue) complex, tissue experiments obtain the density and sound-velocity multiphase gradient distributions, and acoustic fields and beam formation are numerically simulated. The results suggest the control of wave propagations and sound-beam formations is realized by cooperation of the whole forehead's tissues and structures. The melon size significantly impacts the side lobes of the beam and slightly influences the main beams, while the orientation of the vestibular sac mainly adjusts the main beams. By compressing the forehead complex, the sound beam can be expanded for near view. The porpoise's biosonar allows effective wave manipulations for its omnidirectional sound source, which can help the future development of miniaturized biomimetic projectors in underwater sonar, medical ultrasonography, and other ultrasonic imaging applications.

  17. Analysis of a bubble coalescence in the multiphase lattice Boltzmann method

    International Nuclear Information System (INIS)

    Ryu, Seung Yeob; Park, Cheon Tae; Lee, Chung Chan; Kim, Keung Koo

    2008-01-01

    Recently, the lattice Boltzmann method (LBM) has gained much attention for its ability to simulate fluid flows, and for its potential advantages over a conventional CFD method. The key advantages of LBM are, (1) suitability for parallel computations, (2) absence of the need to solve the time-consuming Poisson equation for a pressure, and (3) an ease with multiphase flows, complex geometries and interfacial dynamics may be treated. To study the effect of the mobility coefficient Γ and the width of the interface layer, two stationary bubbles without a collision are considered. The gap of the two bubbles is taken as 4, while the width of the interface (w) and the mobility coefficient Γ are varied. In the present work, the lattice Boltzmann model for multiphase flows proposed by Zheng et al. is used for simulating two stationary bubbles without a collision. By adopting a finite difference gradient operator of a sufficient isotropy, the spurious currents can be made smaller. The main objective of the present work is to establish the lattice Boltzmann method as a viable tool for the simulation of multiphase or multi-component flows

  18. A QCQP Approach for OPF in Multiphase Radial Networks with Wye and Delta Connections: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zamzam, Ahmed, S.; Zhaoy, Changhong; Dall' Anesey, Emiliano; Sidiropoulos, Nicholas D.

    2017-06-27

    This paper examines the AC Optimal Power Flow (OPF) problem for multiphase distribution networks featuring renewable energy resources (RESs). We start by outlining a power flow model for radial multiphase systems that accommodates wye-connected and delta-connected RESs and non-controllable energy assets. We then formalize an AC OPF problem that accounts for both types of connections. Similar to various AC OPF renditions, the resultant problem is a non convex quadratically-constrained quadratic program. However, the so-called Feasible Point Pursuit-Successive Convex Approximation algorithm is leveraged to obtain a feasible and yet locally-optimal solution. The merits of the proposed solution approach are demonstrated using two unbalanced multiphase distribution feeders with both wye and delta connections.

  19. Invasion percolation of single component, multiphase fluids with lattice Boltzmann models

    International Nuclear Information System (INIS)

    Sukop, M.C.; Or, Dani

    2003-01-01

    Application of the lattice Boltzmann method (LBM) to invasion percolation of single component multiphase fluids in porous media offers an opportunity for more realistic modeling of the configurations and dynamics of liquid/vapor and liquid/solid interfaces. The complex geometry of connected paths in standard invasion percolation models arises solely from the spatial arrangement of simple elements on a lattice. In reality, fluid interfaces and connectivity in porous media are naturally controlled by the details of the pore geometry, its dynamic interaction with the fluid, and the ambient fluid potential. The multiphase LBM approach admits realistic pore geometry derived from imaging techniques and incorporation of realistic hydrodynamics into invasion percolation models

  20. Application of the level set method for multi-phase flow computation in fusion engineering

    International Nuclear Information System (INIS)

    Luo, X-Y.; Ni, M-J.; Ying, A.; Abdou, M.

    2006-01-01

    Numerical simulation of multi-phase flow is essential to evaluate the feasibility of a liquid protection scheme for the power plant chamber. The level set method is one of the best methods for computing and analyzing the motion of interface among the multi-phase flow. This paper presents a general formula for the second-order projection method combined with the level set method to simulate unsteady incompressible multi-phase flow with/out phase change flow encountered in fusion science and engineering. The third-order ENO scheme and second-order semi-implicit Crank-Nicholson scheme is used to update the convective and diffusion term. The numerical results show this method can handle the complex deformation of the interface and the effect of liquid-vapor phase change will be included in the future work

  1. NMR studies of multiphase flows II

    Energy Technology Data Exchange (ETDEWEB)

    Altobelli, S.A.; Caprihan, A.; Fukushima, E. [Lovelace Institutes, Albuquerque, NM (United States)] [and others

    1995-12-31

    NMR techniques for measurements of spatial distribution of material phase, velocity and velocity fluctuation are being developed and refined. Versions of these techniques which provide time average liquid fraction and fluid phase velocity have been applied to several concentrated suspension systems which will not be discussed extensively here. Technical developments required to further extend the use of NMR to the multi-phase flow arena and to provide measurements of previously unobtainable parameters are the focus of this report.

  2. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    International Nuclear Information System (INIS)

    Sugiharto, S.; Kurniadi, R.; Abidin, Z.; Stegowski, Z.; Furman, L.

    2013-01-01

    Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT) having an inner diameter of 24 in (60,96 m). The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD) curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD) simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct. (author)

  3. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    Directory of Open Access Journals (Sweden)

    S. Sugiharto1

    2013-04-01

    Full Text Available Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT having an inner diameter of 24 in (60,96 m. The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct

  4. Multi-Phase Modeling of Rainbird Water Injection

    Science.gov (United States)

    Vu, Bruce T.; Moss, Nicholas; Sampson, Zoe

    2014-01-01

    This paper describes the use of a Volume of Fluid (VOF) multiphase model to simulate the water injected from a rainbird nozzle used in the sound suppression system during launch. The simulations help determine the projectile motion for different water flow rates employed at the pad, as it is critical to know if water will splash on the first-stage rocket engine during liftoff.

  5. Multiphase lattice Boltzmann on the Cell Broadband Engine

    International Nuclear Information System (INIS)

    Belletti, F.; Mantovani, F.; Tripiccione, R.; Biferale, L.; Schifano, S.F.; Toschi, F.

    2009-01-01

    Computational experiments are one of the most used and flexible investigation tools in fluid dynamics. The Lattice Boltzmann Equation is a well established computational method particularly promising for multi-phase flows at micro and macro scales. Here we present preliminary results on performances of the Lbe method on the Cell Broadband Engine platform.

  6. Slush Fund: Modeling the Multiphase Physics of Oceanic Ices

    Science.gov (United States)

    Buffo, J.; Schmidt, B. E.

    2016-12-01

    The prevalence of ice interacting with an ocean, both on Earth and throughout the solar system, and its crucial role as the mediator of exchange between the hydrosphere below and atmosphere above, have made quantifying the thermodynamic, chemical, and physical properties of the ice highly desirable. While direct observations of these quantities exist, their scarcity increases with the difficulty of obtainment; the basal surfaces of terrestrial ice shelves remain largely unexplored and the icy interiors of moons like Europa and Enceladus have never been directly observed. Our understanding of these entities thus relies on numerical simulation, and the efficacy of their incorporation into larger systems models is dependent on the accuracy of these initial simulations. One characteristic of seawater, likely shared by the oceans of icy moons, is that it is a solution. As such, when it is frozen a majority of the solute is rejected from the forming ice, concentrating in interstitial pockets and channels, producing a two-component reactive porous media known as a mushy layer. The multiphase nature of this layer affects the evolution and dynamics of the overlying ice mass. Additionally ice can form in the water column and accrete onto the basal surface of these ice masses via buoyancy driven sedimentation as frazil or platelet ice. Numerical models hoping to accurately represent ice-ocean interactions should include the multiphase behavior of these two phenomena. While models of sea ice have begun to incorporate multiphase physics into their capabilities, no models of ice shelves/shells explicitly account for the two-phase behavior of the ice-ocean interface. Here we present a 1D multiphase model of floating oceanic ice that includes parameterizations of both density driven advection within the `mushy layer' and buoyancy driven sedimentation. The model is validated against contemporary sea ice models and observational data. Environmental stresses such as supercooling and

  7. Multiphase flow of immiscible fluids on unstructured moving meshes

    DEFF Research Database (Denmark)

    Misztal, Marek Krzysztof; Erleben, Kenny; Bargteil, Adam

    2012-01-01

    In this paper, we present a method for animating multiphase flow of immiscible fluids using unstructured moving meshes. Our underlying discretization is an unstructured tetrahedral mesh, the deformable simplicial complex (DSC), that moves with the flow in a Lagrangian manner. Mesh optimization op...

  8. Multiphase Flow of Immiscible Fluids on Unstructured Moving Meshes

    DEFF Research Database (Denmark)

    Misztal, Marek Krzysztof; Erleben, Kenny; Bargteil, Adam

    2013-01-01

    In this paper, we present a method for animating multiphase flow of immiscible fluids using unstructured moving meshes. Our underlying discretization is an unstructured tetrahedral mesh, the deformable simplicial complex (DSC), that moves with the flow in a Lagrangian manner. Mesh optimization op...

  9. Droplet and multiphase effects in a shock-driven hydrodynamic instability with reshock

    Science.gov (United States)

    Middlebrooks, John B.; Avgoustopoulos, Constantine G.; Black, Wolfgang J.; Allen, Roy C.; McFarland, Jacob A.

    2018-06-01

    Shock-driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching applications in engineering and science such as high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase field is impulsively accelerated by a shock wave and evolves as a result of gradients in particle-gas momentum transfer. A new shock tube facility has been constructed to study the SDMI. Experiments were conducted to investigate liquid particle and multiphase effects in the SDMI. A multiphase cylindrical interface was created with water droplet laden air in our horizontal shock tube facility. The interface was accelerated by a Mach 1.66 shock wave, and its reflection from the end wall. The interface development was captured using laser illumination and a high-resolution CCD camera. Laser interferometry was used to determine the droplet size distribution. A particle filtration technique was used to determine mass loading within an interface and verify particle size distribution. The effects of particle number density, particle size, and a secondary acceleration (reshock) of the interface were noted. Particle number density effects were found comparable to Atwood number effects in the Richtmyer-Meshkov instability for small (˜ 1.7 {μ }m) droplets. Evaporation was observed to alter droplet sizes and number density, markedly after reshock. For large diameter droplets (˜ 10.7 {μ }m), diminished development was observed with larger droplets lagging far behind the interface. These lagging droplets were also observed to breakup after reshock into structured clusters of smaller droplets. Mixing width values were reported to quantify mixing effects seen in images.

  10. A review of spurious currents in the lattice Boltzmann method for multiphase flows

    Energy Technology Data Exchange (ETDEWEB)

    Conning Ton, Kevin; Lee, Tae Hun [The City College of the City Univ. of New York, New York (United States)

    2012-12-15

    A spurious current is a small amplitude artificial velocity field which arises from an imbalance between discretized forces in multiphase/multi component flows. If it occurs, the velocity field may persist indefinitely, preventing the achievement of a true equilibrium state. Spurious velocities can sometimes be as large as the characteristic velocities of the problem, causing severe instability and ambiguity between physical and spurious velocities. They are typically exacerbated by large values of numerical surface tension or when the two fluids being simulated have large density ratios. The resulting instability can restrict what parameters may be simulated. To varying degrees, spurious currents are found in all multiphase flow models of the lattice Boltzmann method (LBM). There have been many studies of the occurrence of the phenomenon, and many suggestions on how to eliminate it. This paper reviews the three main models of simulating multiphase/multi component flow in the lattice Boltzmann method, as well as the subsequent modifications made in order to reduce or eliminate spurious currents.

  11. The validity of multiphase DNS initialized on the basis of single--point statistics

    Science.gov (United States)

    Subramaniam, Shankar

    1999-11-01

    A study of the point--process statistical representation of a spray reveals that single--point statistical information contained in the droplet distribution function (ddf) is related to a sequence of single surrogate--droplet pdf's, which are in general different from the physical single--droplet pdf's. The results of this study have important consequences for the initialization and evolution of direct numerical simulations (DNS) of multiphase flows, which are usually initialized on the basis of single--point statistics such as the average number density in physical space. If multiphase DNS are initialized in this way, this implies that even the initial representation contains certain implicit assumptions concerning the complete ensemble of realizations, which are invalid for general multiphase flows. Also the evolution of a DNS initialized in this manner is shown to be valid only if an as yet unproven commutation hypothesis holds true. Therefore, it is questionable to what extent DNS that are initialized in this manner constitute a direct simulation of the physical droplets.

  12. [IMPROVEMENT AND CHOICE OF COLOSTOMY METHOD IN THE TREATMENT OF PATIENTS, SUFFERING AN ACUTE OBTURATIVE IMPASSABILITY OF LARGE BOWEL].

    Science.gov (United States)

    Kustryo, V I; Langazo, O V

    2015-11-01

    Colostomy was done in 49 patients, suffering an acute obturative impassability of large bowel (AOILB). In 28 patients (1st group) colostomy was conducted in accordance to standard method; in 21 (2nd group)--in accordance to the method, proposed by us. Application of the method proposed for surgical treatment of AOILB have guaranteed a reduction of postoperative paracolostomal complications rate in 6.8 times, of postoperative lethality--in 2.2 times, duration of the patient stationary treatment--in 1.4 times, the rate of dressings and the dressing material expanses--in 10 times.

  13. Measurement Of Multiphase Flow Water Fraction And Water-cut

    Science.gov (United States)

    Xie, Cheng-gang

    2007-06-01

    This paper describes a microwave transmission multiphase flow water-cut meter that measures the amplitude attenuation and phase shift across a pipe diameter at multiple frequencies using cavity-backed antennas. The multiphase flow mixture permittivity and conductivity are derived from a unified microwave transmission model for both water- and oil-continuous flows over a wide water-conductivity range; this is far beyond the capability of microwave-resonance-based sensors currently on the market. The water fraction and water cut are derived from a three-component gas-oil-water mixing model using the mixture permittivity or the mixture conductivity and an independently measured mixture density. Water salinity variations caused, for example, by changing formation water or formation/injection water breakthrough can be detected and corrected using an online water-conductivity tracking technique based on the interpretation of the mixture permittivity and conductivity, simultaneously measured by a single-modality microwave sensor.

  14. Calculation of Multiphase Chemical Equilibrium by the Modified RAND Method

    DEFF Research Database (Denmark)

    Tsanas, Christos; Stenby, Erling Halfdan; Yan, Wei

    2017-01-01

    method. The modified RAND extends the classical RAND method from single-phase chemical reaction equilibrium of ideal systems to multiphase chemical equilibrium of nonideal systems. All components in all phases are treated in the same manner and the system Gibbs energy can be used to monitor convergence....... This is the first time that modified RAND was applied to multiphase chemical equilibrium systems. The combined algorithm was tested using nine examples covering vapor–liquid (VLE) and vapor–liquid–liquid equilibria (VLLE) of ideal and nonideal reaction systems. Successive substitution provided good initial......A robust and efficient algorithm for simultaneous chemical and phase equilibrium calculations is proposed. It combines two individual nonstoichiometric solving procedures: a nested-loop method with successive substitution for the first steps and final convergence with the second-order modified RAND...

  15. Annihilation Radiation Gauge for Relative Density and Multiphase Fluid Monitoring

    Directory of Open Access Journals (Sweden)

    Vidal A.

    2014-03-01

    Full Text Available The knowledge of the multi-phase flow parameters are important for the petroleum industry, specifically during the transport in pipelines and network related to exploitation’s wells. Crude oil flow is studied by Monte Carlo simulation and experimentally to determine transient liquid phase in a laboratory system. Relative density and fluid phase time variation is monitored employing a fast nuclear data acquisition setup that includes two large volume BaF2 scintillator detectors coupled to an electronic chain and data display in a LabView® environment. Fluid parameters are determined by the difference in count rate of coincidence pulses. The operational characteristics of the equipment indicate that 2 % deviation in the CCR corresponds to a variation, on average, of 20 % in the fraction of liquid of the multiphase fluid.

  16. Convection in multiphase fluid flows using lattice Boltzmann methods

    NARCIS (Netherlands)

    Biferale, L.; Perlekar, P.; Sbragaglia, M.; Toschi, F.

    2012-01-01

    We present high-resolution numerical simulations of convection in multiphase flows (boiling) using a novel algorithm based on a lattice Boltzmann method. We first study the thermodynamical and kinematic properties of the algorithm. Then, we perform a series of 3D numerical simulations changing the

  17. Multiphasic modeling of charged solute transport across articular cartilage: Application of multi-zone finite-bath model.

    Science.gov (United States)

    Arbabi, Vahid; Pouran, Behdad; Weinans, Harrie; Zadpoor, Amir A

    2016-06-14

    Charged and uncharged solutes penetrate through cartilage to maintain the metabolic function of chondrocytes and to possibly restore or further breakdown the cartilage tissue in different stages of osteoarthritis. In this study the transport of charged solutes across the various zones of cartilage was quantified, taken into account the physicochemical interactions between the solute and the cartilage constituents. A multiphasic finite-bath finite element (FE) model was developed to simulate equine cartilage diffusion experiments that used a negatively charged contrast agent (ioxaglate) in combination with serial micro-computed tomography (micro-CT) to measure the diffusion. By comparing the FE model with the experimental data both the diffusion coefficient of ioxaglate and the fixed charge density (FCD) were obtained. In the multiphasic model, cartilage was divided into multiple (three) zones to help understand how diffusion coefficient and FCD vary across cartilage thickness. The direct effects of charged solute-FCD interaction on diffusion were investigated by comparing the diffusion coefficients derived from the multiphasic and biphasic-solute models. We found a relationship between the FCD obtained by the multiphasic model and ioxaglate partitioning obtained from micro-CT experiments. Using our multi-zone multiphasic model, diffusion coefficient of the superficial zone was up to ten-fold higher than that of the middle zone, while the FCD of the middle zone was up to almost two-fold higher than that of the superficial zone. In conclusion, the developed finite-bath multiphasic model provides us with a non-destructive method by which we could obtain both diffusion coefficient and FCD of different cartilage zones. The outcomes of the current work will also help understand how charge of the bath affects the diffusion of a charged molecule and also predict the diffusion behavior of a charged solute across articular cartilage. Copyright © 2016 Elsevier Ltd. All

  18. Superior perioperative analgesia with combined femoral-obturator-sciatic nerve block in comparison with posterior lumbar plexus and sciatic nerve block for ACL reconstructive surgery.

    Science.gov (United States)

    Bareka, Metaxia; Hantes, Michael; Arnaoutoglou, Eleni; Vretzakis, George

    2018-02-01

    The purpose of this randomized controlled study is to compare and evaluate the intraoperative and post-operative outcome of PLPS nerve block and that of femoral, obturator and sciatic (FOS) nerve block as a method of anaesthesia, in performing ACL reconstruction. Patients referred for elective arthroscopic ACL reconstruction using hamstring autograft were divided in two groups. The first group received combined femoral-obturator-sciatic nerve block (FOS Group) under dual guidance, whereas the second group received posterior lumbar plexus block under neurostimulation and sciatic nerve block (PLPS Group) under dual guidance. The two groups were comparable in terms of age, sex, BMI and athletic activity. The time needed to perform the nerve blocks was significantly shorter for the FOS group (p block under dual guidance for arthroscopic ACL reconstructive surgery is a safe and tempting anaesthetic choice. The success rate of this technique is higher in comparison with PLPS and results in less peri- and post-operative pain with less opioid consumption. This study provides support for the use of peripheral nerve blocks as an exclusive method for ACL reconstructive surgery in an ambulatory setting with almost no complications. I.

  19. Analysis of hygral induced crack growth in multiphase materials

    NARCIS (Netherlands)

    Sadouki, H.; Van Mier, J.G.M.

    1996-01-01

    In this paper a numerical model for simulating crack growth processes caused by moisture movement in a porous multiphase material like concrete is proposed. In the model, the material is schematized as a regular triangular network of beam elements. The meso-material structure of the material is

  20. Novel image reconstruction algorithm for multi-phase flow tomography system using γ ray method

    International Nuclear Information System (INIS)

    Hao Kuihong; Wang Huaxiang; Gao Mei

    2007-01-01

    After analyzing the reason of image reconstructed algorithm by using the conventional back projection (IBP) is prone to produce spurious line, and considering the characteristic of multi-phase flow tomography, a novel image reconstruction algorithm is proposed, which carries out the intersection calculation using back projection data. This algorithm can obtain a perfect system point spread function, and can eliminate spurious line better. Simulating results show that the algorithm is effective for identifying multi-phase flow pattern. (authors)

  1. Multi-phase chemistry in process simulation - MASIT04 (VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Brink, A.; Li Bingzhi; Hupa, M. (Aabo Akademi University, Combustion and Materials Chemistry, Turku (Finland)) (and others)

    2008-07-01

    A new generation of process models has been developed by using advanced multi-phase thermochemistry. The generality of the thermodynamic free energy concept enables use of common software tools for high and low temperature processes. Reactive multi-phase phenomena are integrated to advanced simulation procedures by using local equilibrium or constrained state free energy computation. The high-temperature applications include a process model for the heat recovery of copper flash smelting and coupled models for converter and bloom casting operations in steel-making. Wet suspension models are developed for boiler and desalination water chemistry, flash evaporation of black liquor and for selected fibre-line and paper-making processes. The simulation combines quantitative physical and chemical data from reactive flows to form their visual images, thus providing efficient tools for engineering design and industrial decision-making. Economic impacts are seen as both better process operations and improved end products. The software tools developed are internationally commercialised and being used to support Finnish process technology exports. (orig.)

  2. Surface Tension of Multi-phase Flow with Multiple Junctions Governed by the Variational Principle

    International Nuclear Information System (INIS)

    Matsutani, Shigeki; Nakano, Kota; Shinjo, Katsuhiko

    2011-01-01

    We explore a computational model of an incompressible fluid with a multi-phase field in three-dimensional Euclidean space. By investigating an incompressible fluid with a two-phase field geometrically, we reformulate the expression of the surface tension for the two-phase field found by Lafaurie et al. (J Comput Phys 113:134–147, 1994) as a variational problem related to an infinite dimensional Lie group, the volume-preserving diffeomorphism. The variational principle to the action integral with the surface energy reproduces their Euler equation of the two-phase field with the surface tension. Since the surface energy of multiple interfaces even with singularities is not difficult to be evaluated in general and the variational formulation works for every action integral, the new formulation enables us to extend their expression to that of a multi-phase (N-phase, N ≥ 2) flow and to obtain a novel Euler equation with the surface tension of the multi-phase field. The obtained Euler equation governs the equation for motion of the multi-phase field with different surface tension coefficients without any difficulties for the singularities at multiple junctions. In other words, we unify the theory of multi-phase fields which express low dimensional interface geometry and the theory of the incompressible fluid dynamics on the infinite dimensional geometry as a variational problem. We apply the equation to the contact angle problems at triple junctions. We computed the fluid dynamics for a two-phase field with a wall numerically and show the numerical computational results that for given surface tension coefficients, the contact angles are generated by the surface tension as results of balances of the kinematic energy and the surface energy.

  3. Eliminating cubic terms in the pseudopotential lattice Boltzmann model for multiphase flow

    Science.gov (United States)

    Huang, Rongzong; Wu, Huiying; Adams, Nikolaus A.

    2018-05-01

    It is well recognized that there exist additional cubic terms of velocity in the lattice Boltzmann (LB) model based on the standard lattice. In this work, elimination of these cubic terms in the pseudopotential LB model for multiphase flow is investigated, where the force term and density gradient are considered. By retaining high-order (≥3 ) Hermite terms in the equilibrium distribution function and the discrete force term, as well as introducing correction terms in the LB equation, the additional cubic terms of velocity are entirely eliminated. With this technique, the computational simplicity of the pseudopotential LB model is well maintained. Numerical tests, including stationary and moving flat and circular interface problems, are carried out to show the effects of such cubic terms on the simulation of multiphase flow. It is found that the elimination of additional cubic terms is beneficial to reduce the numerical error, especially when the velocity is relatively large. Numerical results also suggest that these cubic terms mainly take effect in the interfacial region and that the density-gradient-related cubic terms are more important than the other cubic terms for multiphase flow.

  4. Multi-Phase Modular Drive System: A Case Study in Electrical Aircraft Applications

    Directory of Open Access Journals (Sweden)

    Charles Onambele

    2017-12-01

    Full Text Available In this article, an advanced multiphase modular power drive prototype is developed for More Electric Aircraft (MEA. The proposed drive is designed to supply a multi-phase permanent magnet (PM motor rating 120 kW with 24 slots and 11 pole pairs. The power converter of the drive system is based on Silicon Carbide Metal Oxide Semiconductor Field-Effect Transistor (SiC MOSFET technology to operate at high voltage, high frequency and low reverse recovery current. Firstly, an experimental characterization test is performed for the selected SiC power module in harsh conditions to evaluate the switching energy losses. Secondly, a finite element thermal analysis based on Ansys-Icepak is accomplished to validate the selected cooling system for the power converter. Thirdly, a co-simulation model is developed using Matlab-Simulink and LTspice® to evaluate the SiC power module impact on the performance of a multiphase drive system at different operating conditions. The results obtained show that the dynamic performance and efficiency of the power drive are significantly improved, which makes the proposed system an excellent candidate for future aircraft applications.

  5. Experimental and computational analysis of pressure response in a multiphase flow loop

    Science.gov (United States)

    Morshed, Munzarin; Amin, Al; Rahman, Mohammad Azizur; Imtiaz, Syed

    2016-07-01

    The characteristics of multiphase fluid flow in pipes are useful to understand fluid mechanics encountered in the oil and gas industries. In the present day oil and gas exploration is successively inducing subsea operation in the deep sea and arctic condition. During the transport of petroleum products, understanding the fluid dynamics inside the pipe network is important for flow assurance. In this case the information regarding static and dynamic pressure response, pressure loss, optimum flow rate, pipe diameter etc. are the important parameter for flow assurance. The principal aim of this research is to represents computational analysis and experimental analysis of multi-phase (L/G) in a pipe network. This computational study considers a two-phase fluid flow through a horizontal flow loop with at different Reynolds number in order to determine the pressure distribution, frictional pressure loss profiles by volume of fluid (VOF) method. However, numerical simulations are validated with the experimental data. The experiment is conducted in 76.20 mm ID transparent circular pipe using water and air in the flow loop. Static pressure transducers are used to measure local pressure response in multiphase pipeline.

  6. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  7. New Multiphase Hybrid Boost Converter with Wide Conversion Ratio for PV System

    Directory of Open Access Journals (Sweden)

    Ioana-Monica Pop-Calimanu

    2014-01-01

    Full Text Available A new multiphase hybrid boost converter, with wide conversion ratio as a solution for photovoltaic energy system, is presented in this paper. To ensure that all the phases of the converter operate at the same switching frequency we use interleaving topology. The proposed converter can be used as an interface between the PV system and the DC load/inverter. This multiphase converter has the advantage of reduced value and physical size of the input and output capacitor as well as the effort for the inductors. To validate the operation of the converter we provide the analyses and the simulation results of the converter.

  8. A novel photocatalytic monolith reactor for multiphase heterogeneous photocatalysis

    NARCIS (Netherlands)

    Du, P.; Carneiro, J.T.; Moulijn, J.A.; Mul, Guido

    2008-01-01

    A novel reactor for multi-phase photocatalysis is presented, the so-called internally illuminated monolith reactor (IIMR). In the concept of the IIMR, side light emitting fibers are placed inside the channels of a ceramic monolith, equipped with a TiO2 photocatalyst coated on the wall of each

  9. Multiphase fluid structure interaction in bends and T-joints

    NARCIS (Netherlands)

    Cargnelutti, M.F.; Belfroid, S.P.C.; Schiferli, W.; Osch, M.M.E. van

    2010-01-01

    Air-water experiments were carried out in a horizontal 1" pipe system to measure the magnitude of the forces induced by the multiphase flow. Forces and accelerations were measured on a number of bends and T-joint configurations for a wide range of operating conditions. Five different configurations

  10. Development and Research of Peristaltic Multiphase Piezoelectric Micro-Pump

    Science.gov (United States)

    Vinogradov, Alexander N.; Ivanikin, Igor A.; Lubchenco, Roman V.; Matveev, Yegor V.; Titov, Pavel A.

    2016-01-01

    The paper presents the results of a study of existing models and mathematical representations of a range of truly peristaltic multiphase micro-pumps with a piezoelectric actuator (piezo drive). Piezo drives with different types of substrates use vertical movements at deformation of individual piezoelectric elements, which define device…

  11. Modified Invasion Percolation Models for Multiphase Processes

    Energy Technology Data Exchange (ETDEWEB)

    Karpyn, Zuleima [Pennsylvania State Univ., State College, PA (United States)

    2015-01-31

    This project extends current understanding and modeling capabilities of pore-scale multiphase flow physics in porous media. High-resolution X-ray computed tomography imaging experiments are used to investigate structural and surface properties of the medium that influence immiscible displacement. Using experimental and computational tools, we investigate the impact of wetting characteristics, as well as radial and axial loading conditions, on the development of percolation pathways, residual phase trapping and fluid-fluid interfacial areas.

  12. Isothermal Multiphase Flash Calculations with the PC-SAFT Equation of State

    International Nuclear Information System (INIS)

    Justo-Garcia, Daimler N.; Garcia-Sanchez, Fernando; Romero-Martinez, Ascencion

    2008-01-01

    A computational approach for isothermal multiphase flash calculations with the PC-SAFT (Perturbed-Chain Statistical Associating Fluid Theory) equation of state is presented. In the framework of the study of fluid phase equilibria of multicomponent systems, the general multiphase problem is the single most important calculation which consists of finding the correct number and types of phases and their corresponding equilibrium compositions such that the Gibbs energy of the system is a minimum. For solving this problem, the system Gibbs energy was minimized using a rigorous method for thermodynamic stability analysis to find the most stable state of the system. The efficiency and reliability of the approach to predict and calculate complex phase equilibria are illustrated by solving three typical problems encountered in the petroleum industry

  13. A randomised controlled trial of ultrasound-guided blockade of the saphenous nerve and the posterior branch of the obturator nerve for postoperative analgesia after day-case knee arthroscopy

    DEFF Research Database (Denmark)

    Westergaard, B; Jensen, K; Lenz, K

    2014-01-01

    The purpose of this study was to investigate the effects of blockade of the saphenous nerve and the posterior branch of the obturator nerve in addition to a standard analgesic regimen for patients discharged the same day after knee arthroscopy. The primary outcome was knee pain on flexion during...

  14. Designing of Multiphase Fly Ash/MWCNT/PU Composite Sheet Against Electromagnetic Environmental Pollution

    Science.gov (United States)

    Gujral, Parth; Varshney, Swati; Dhawan, S. K.

    2016-06-01

    Fly ash and multiwalled carbon nanotubes (MWCNT) reinforced multiphase polyurethane (PU) composite sheets have been fabricated by using a solution casting technique. Utilization of fly ash was the prime objective in order to reduce environmental pollution and to enhance the shielding properties of PU polymer. Our study proves that fly ash particles with MWCNTs in a PU matrix leads to novel hybrid high performance electromagnetic shielding interference material. Scanning electron microscopy confirms the existence of fly ash particles along with MWCNTs in a PU matrix. This multiphase composite shows total shielding effectiveness of 35.8 dB (>99.99% attenuation) in the Ku-band (12.4-18 GHz) frequency range. This is attributed to high dielectric losses of reinforcement present in the polymers matrix. The Nicolson-Ross-Weir algorithm has been applied to calculate the electromagnetic attributes and dielectric parameters of the PU samples by using scattering parameters ( S 11, S 22, S 12, S 21). The synthesized multiphase composites were further characterized by using x-ray diffraction, Fourier transform infrared spectroscopy, and thermo gravimetric analysis.

  15. Application of GPU to computational multiphase fluid dynamics

    International Nuclear Information System (INIS)

    Nagatake, T; Kunugi, T

    2010-01-01

    The MARS (Multi-interfaces Advection and Reconstruction Solver) [1] is one of the surface volume tracking methods for multi-phase flows. Nowadays, the performance of GPU (Graphics Processing Unit) is much higher than the CPU (Central Processing Unit). In this study, the GPU was applied to the MARS in order to accelerate the computation of multi-phase flows (GPU-MARS), and the performance of the GPU-MARS was discussed. From the performance of the interface tracking method for the analyses of one-directional advection problem, it is found that the computing time of GPU(single GTX280) was around 4 times faster than that of the CPU (Xeon 5040, 4 threads parallelized). From the performance of Poisson Solver by using the algorithm developed in this study, it is found that the performance of the GPU showed around 30 times faster than that of the CPU. Finally, it is confirmed that the GPU showed the large acceleration of the fluid flow computation (GPU-MARS) compared to the CPU. However, it is also found that the double-precision computation of the GPU must perform with very high precision.

  16. Case study in Venezuela : performance of multiphase meter in extra heavy oil

    Energy Technology Data Exchange (ETDEWEB)

    Marin, A. [Petroleos de Venezuela SA, Caracas (Venezuela); Bornia, O.; Pinguet, B. [Schlumberger Canada Ltd., Edmonton, AB (Canada)

    2008-10-15

    The performance of a multiphase meter that combines Venturi and multi energy gamma rays was investigated during operation in an extra heavy oil field in Venezuela. The Orocual field in Monagas is one of the most diverse oilfields in Venezuela. It produces gas condensate, light and medium oil and has recently started to produce from a heavy and extra-heavy oil reservoir, with a gravity between 8.6 and 11 API and a viscosity range from 6 Pa.s to more than 20 Pa.s at line conditions. Petroleos de Venezuela SA (PDVSA) is currently using cold production systems in this field. PDVSA attempted to estimate the liquid flow rate using conventional storage tanks but was unable to evaluate the gas production in such an environment of low GOR with emulsion, large amounts of foam and high viscosity. Since the density of heavy oil is close to the density of water, gravity separation cannot be applied. Also, since heavy oil is very viscous, proper separation requires a long retention time, which is not feasible in terms of space or economy. In addition, gas bubbles could not flow freely and remained as a gas phase trapped inside the liquid, resulting in an overestimation of some of the liquid flow rate. In order to measure the field's oil, water and gas flow rates, PDVSA tried several multiphase meters but found that a Venturi and multi energy gamma ray combination was the only solution able to accurately measure multiphase flow in its extra heavy oil. A test demonstrated that, compared to a tank system, the overall uncertainty of the Venturi combination was better than 2 per cent. This extended the operating envelope for PDVSA for using this multiphase metering technology, providing the capability to monitor and optimize in real-time the production in this extra heavy oil field. 15 refs., 10 figs.

  17. A novel anti-frictional multiphase layer produced by plasma nitriding of PVD titanium coated ZL205A aluminum alloy

    Science.gov (United States)

    Lu, C.; Yao, J. W.; Wang, Y. X.; Zhu, Y. D.; Guo, J. H.; Wang, Y.; Fu, H. Y.; Chen, Z. B.; Yan, M. F.

    2018-02-01

    The heat treatment (consisting of solid solution and aging), is integrated with the nitriding process of titanium coated ZL205A aluminum alloy to improve the surface and matrix mechanical properties simultaneously. Two-step duplex treatment is adopted to prepare the gradient multiphase layer on a magnesium-free ZL205A aluminum-copper based alloy. Firstly, pure titanium film is deposited on the aluminum alloy substrate using magnetron sputtering. Secondly, the Ti-coated specimen is nitrided at the solid solution temperature of the substrate alloying elements in a gas mixture of N2 and H2 and aged at 175 °C. The microstructure evolution, microhardness as well as the wear resistance of obtained multiphase layers are investigated by means of scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectrometer (EDS), microhardness tester and pin-on-disc tribometer. The multiphase layer, dominated by TiN0.3 or Al3Ti, is prepared with significantly increased layer depth after duplex treatment. The surface hardness of multiphase layer is remarkably improved from 23.7HV to 457HV. The core matrix hardness is also increased to 65HV after aging. The wear rate of the multiphase layer decreases about 55.22% and 49.28% in comparison with the aged and Ti coated specimens, respectively. The predominant wear mechanism for the multiphase layer is abrasive and oxidation, but severe adhesive wear for the aged and Ti coated specimens.

  18. Application of multiphase flow methods to horizontal underbalanced drilling

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S. P.; Gregory, G. A.; Munro, N.; Muqeem, M.

    1998-12-31

    Ways in which multiphase flow pressure loss calculations can be used in the design and optimization of underbalanced drilling operations are demonstrated. Existing pressure loss calculation methods are evaluated using detailed field measurements for three oil wells and one gas well drilled underbalanced with coiled tubing. 10 refs., 3 tabs., 17 figs.

  19. A multiphase series-resonant converter with a reduced number of thyristors and common grounds for inputs and outputs

    NARCIS (Netherlands)

    Huisman, H.

    1993-01-01

    Multiphase series-resonant (SR) power converters provide a flexible way to transform power between a utility grid and a multiphase load or source. The current implementations all suffer from a high component count, which makes the use of these converters unattractive from an economical point of

  20. Comparative FEM-based Analysis of Multiphase Induction Motor

    Directory of Open Access Journals (Sweden)

    Leonard Livadaru

    2014-09-01

    Full Text Available This paper presents a comparative study of multiphase induction motor, which has alternately three-, five- and six-phase stator winding. The machine has been designed particularly for this purpose and has individual ring coils placed in each stator slot. The study consists in FEM analyses and mainly looks for the particularities of magnetic quantities such as air-gap flux density and electromagnetic torque.

  1. Multiphase flow and phase change in microgravity: Fundamental research and strategic research for exploration of space

    Science.gov (United States)

    Singh, Bhim S.

    2003-01-01

    NASA is preparing to undertake science-driven exploration missions. The NASA Exploration Team's vision is a cascade of stepping stones. The stepping-stone will build the technical capabilities needed for each step with multi-use technologies and capabilities. An Agency-wide technology investment and development program is necessary to implement the vision. The NASA Exploration Team has identified a number of areas where significant advances are needed to overcome all engineering and medical barriers to the expansion of human space exploration beyond low-Earth orbit. Closed-loop life support systems and advanced propulsion and power technologies are among the areas requiring significant advances from the current state-of-the-art. Studies conducted by the National Academy of Science's National Research Council and Workshops organized by NASA have shown that multiphase flow and phase change play a crucial role in many of these advanced technology concepts. Lack of understanding of multiphase flow, phase change, and interfacial phenomena in the microgravity environment has been a major hurdle. An understanding of multiphase flow and phase change in microgravity is, therefore, critical to advancing many technologies needed. Recognizing this, the Office of Biological and Physical Research (OBPR) has initiated a strategic research thrust to augment the ongoing fundamental research in fluid physics and transport phenomena discipline with research especially aimed at understanding key multiphase flow related issues in propulsion, power, thermal control, and closed-loop advanced life support systems. A plan for integrated theoretical and experimental research that has the highest probability of providing data, predictive tools, and models needed by the systems developers to incorporate highly promising multiphase-based technologies is currently in preparation. This plan is being developed with inputs from scientific community, NASA mission planners and industry personnel

  2. Evaluation of tumor response to intra-arterial chemoembolization of hepatocellular carcinoma: Comparison of contrast-enhanced ultrasound with multiphase computed tomography.

    Science.gov (United States)

    Paul, S B; Dhamija, E; Gamanagatti, S R; Sreenivas, V; Yadav, D P; Jain, S; Shalimar; Acharya, S K

    2017-03-01

    To compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) with that of multiphase computed tomography (CT) in the evaluation of tumor response to transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). Fifty patients (41 men, 9 women; mean age, 53 years±12.5 [SD]) with a total of 70 HCCs (mean size, 5cm±3 [SD]) were evaluated. Post-TACE therapeutic assessment of HCC was done at 4 weeks. Patients with TACE done earlier and reporting with suspicion for recurrence were also included. Patients with hepatic masses seen on ultrasound were enrolled and subjected to CEUS, multiphase CT and magnetic resonance imaging (MRI). Hyperenhancing area at the tumor site on arterial phase of CEUS/multiphase CT/MRI was termed as residual disease (RD), the patterns of which were described on CEUS. Diagnostic accuracies of CEUS and MPCT were compared to that of MRI that was used as the reference standard. CEUS detected RD in 43/70 HCCs (61%). RD had a heterogeneous pattern in 22/43 HCCs (51%). Sensitivities of CEUS and multiphase CT were 94% (34/36; 95% CI: 81-99%) and 50% (18/36; 95% CI: 33-67%) respectively. Significant difference in sensitivity was found between CEUS and multiphase CT (P=0.0001). CEUS and multiphase CT had 100% specificity (95% CI: 83-100%). CEUS is a useful technique for detecting RD in HCC after TACE. For long term surveillance, CEUS should be complemented with multiphase CT/MRI for a comprehensive evaluation. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  3. Multiphase simulation of mine waters and aqueous leaching processes

    Directory of Open Access Journals (Sweden)

    Pajarre Risto

    2016-01-01

    Full Text Available Managing of large amounts of water in mining and mineral processing sites remains a concern in both actively operated and closed mining areas. When the mining site with its metal or concentrate producing units is operational, the challenge is to find either ways for economical processing with maximum yields, while minimizing the environmental impact of the water usage and waste salt treatments. For safe closure of the site, the environmental control of possible drainage will be needed. For both challenges, the present-day multiphase process simulations tools can be used to provide improved accuracy and better economy in controlling the smooth and environmentally sound operation of the plant. One of the pioneering studies in using the multiphase thermodynamic software in simulation of hydrometallurgical processes was that of Koukkari et al. [1]. The study covered the use of Solgasmix equilibrium software for a number of practical acid digesters. The models were made for sulfuric acid treatments in titania pigment production and in NPK fertilizer manufacturing. During the past two decades the extensive data assessment has taken place particularly in geochemistry and a new versions of geochemical multiphase equilibrium software has been developed. On the other hand, there has been some progress in development of the process simulation software in all the aforementioned fields. Thus, the thermodynamic simulation has become a tool of great importance in development of hydrometallurgical processes. The presentation will cover three example cases of either true pilot or industrial systems including a South African acid mine water drainage treatment, hydrometallurgical extraction of rare earths from uranium leachate in Russia and a multistage process simulation of a Finnish heap leaching mine with its subsequent water treatment system.

  4. Non-isothermal effects on multi-phase flow in porous medium

    DEFF Research Database (Denmark)

    Singh, Ashok; Wang, W; Park, C. H.

    2010-01-01

    In this paper a ppT -formulation for non-isothermal multi-phase flow is given including diffusion and latent heat effects. Temperature and pressure dependencies of governing parameters are considered, in particular surface tension variation on phase interfaces along with temperature changes. A we...

  5. Euler-Lagrange modeling of the hydrodynamics of dense multiphase flows

    NARCIS (Netherlands)

    Padding, J.T.; Deen, N.G.; Peters, E. A. J. F.; Kuipers, J. A. M.

    2015-01-01

    The large-scale hydrodynamic behavior of relatively dense dispersed multiphase flows, such as encountered in fluidized beds, bubbly flows, and liquid sprays, can be predicted efficiently by use of Euler-Lagrange models. In these models, grid-averaged equations for the continuous-phase flow field are

  6. Multi-phase flow modeling of soil contamination and soil remediation

    NARCIS (Netherlands)

    Dijke, van M.I.J.

    1997-01-01


    In this thesis multi-phase flow models are used to study the flow behavior of liquid contaminants in aquifers and of gases that are injected below the groundwater table for remediation purposes. Considered problems are redistribution of a lens of light nonaqueous phase

  7. Using simulation-optimization techniques to improve multiphase aquifer remediation

    Energy Technology Data Exchange (ETDEWEB)

    Finsterle, S.; Pruess, K. [Lawrence Berkeley Laboratory, Berkeley, CA (United States)

    1995-03-01

    The T2VOC computer model for simulating the transport of organic chemical contaminants in non-isothermal multiphase systems has been coupled to the ITOUGH2 code which solves parameter optimization problems. This allows one to use linear programming and simulated annealing techniques to solve groundwater management problems, i.e. the optimization of operations for multiphase aquifer remediation. A cost function has to be defined, containing the actual and hypothetical expenses of a cleanup operation which depend - directly or indirectly - on the state variables calculated by T2VOC. Subsequently, the code iteratively determines a remediation strategy (e.g. pumping schedule) which minimizes, for instance, pumping and energy costs, the time for cleanup, and residual contamination. We discuss an illustrative sample problem to discuss potential applications of the code. The study shows that the techniques developed for estimating model parameters can be successfully applied to the solution of remediation management problems. The resulting optimum pumping scheme depends, however, on the formulation of the remediation goals and the relative weighting between individual terms of the cost function.

  8. Knowledge regarding technical aspects of non-surgical root canal treatment in Al-Madinah Al-Munawarah private dental centers

    Directory of Open Access Journals (Sweden)

    Mothanna Alrahabi

    2015-01-01

    Full Text Available Objective: We evaluated knowledge of technical aspects of non-surgical root canal treatment among general dentists in private dental clinics in Al-Madinah Al-Munawarah, Saudi Arabia. Materials and Methods: A questionnaire was distributed randomly to 70 general dental practitioners who were working in private dental centers. The response rate was 88.6%. Results: The results showed that only 3% of dentists were using rubber dams for isolation during endodontic treatment. The majority (59.7% were using radiographs to determine the length. Also, 37% were using nickel-titanium (NiTi rotary instruments to prepare the root canal. The lateral condensation technique with gutta percha points to fill the root canal was used by most respondents (77.5%. Conclusions: This study provides important data on endodontic treatment by general dental practitioners in Al-Madinah Al-Munawarah private dental centers. It shows a general lack of knowledge regarding the importance of using rubber dams as well as the new endodontic materials and methods. Continuing education programs to update their knowledge in the field of endodontics are essential.

  9. Unusual Root Canal Morphology of the Maxillary Second Molar: A Case Report

    Directory of Open Access Journals (Sweden)

    Neslihan Şımşek

    2013-01-01

    Full Text Available Introduction. This clinical case report presents the successful endodontic treatment of a maxillary second molar that has a mandibular molar-like anatomy with no palatal root and with each of its roots containing two separate root canals. Cone-beam computed tomography (CBCT was used to confirm this unusual anatomy. Methods. A 34-year-old male patient was referred to the Department of Endodontics at Inonu University’s Faculty of Dentistry because of severe pain in his right maxillary second molar. Clinical and radiographic examinations identified unusual roots and root canals anatomy, and CBCT was planned in order to understand the nature of these variations. Cleaning and shaping procedures were performed using the crown down technique with Sybron Endo (Glendora, CA, USA rotary instruments, and endodontic treatment was completed with gutta-percha cones and AH Plus resin sealers using the cold lateral compaction technique. Conclusions. The maxillary second molar exhibits aberrations and variations in terms of the numbers and configurations of its roots and root canals, and CBCT can be a useful imaging technique in endodontics.

  10. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  11. Management of foreign object in the root canal of central incisor tooth

    Directory of Open Access Journals (Sweden)

    Mothanna Alrahabi

    2014-01-01

    Full Text Available There are several reports describing the impaction of foreign objects into the exposed pulp chambers and canals by patients, especially children as they often have the habit of inserting foreign objects in the oral cavity. These objects will become a potent source of infection.This case report describes the retrieval of a foreign object impacted into the root canal of a 12-year-old male patient who was referred to the endodontic specialty clinic at Taibah University College of Dentistry. The patient′s chief complaint was a pain in the upper left central tooth. Clinical examination revealed a complicated enamel-dentin fracture with a large caries cavity. A periapical radiographic image showed a radiopaque object in the root canal system. Stainless steel Hedstrom files were used to retrieve the object from the canal. Following a proper cleaning and shaping of the root canal system, an intra-canal calcium hydroxide dressing was placed for 1 week. The root canal system was then filled with sealer and gutta-percha using the lateral compaction technique and the tooth received an aesthetic restoration.

  12. Salacia crassifolia (Celastraceae: CHEMICAL CONSTITUENTS AND ANTIMICROBIAL ACTIVITY

    Directory of Open Access Journals (Sweden)

    Vanessa G. Rodrigues

    2015-02-01

    Full Text Available The phytochemical study of hexane extract from leaves of Salacia crassifolia resulted in the isolation of 3β-palmitoxy-urs-12-ene, 3-oxofriedelane, 3β-hydroxyfriedelane, 3-oxo-28-hydroxyfriedelane, 3-oxo-29-hydroxyfriedelane, 28,29-dihydroxyfriedelan-3-one, 3,4-seco-friedelan-3-oic acid, 3β-hydroxy-olean-9(11:12-diene and the mixture of α-amirin and β-amirin. β-sitosterol, the polymer gutta-percha, squalene and eicosanoic acid were also isolated. The chemical structures of these constituents were established by IR, 1H and 13C NMR spectral data. Crude extracts and the triterpenes were tested against Entamoeba histolytica, Giardia lamblia and Trichomonas vaginalis and no activity was observed under the in vitro assay conditions. The hexane, chloroform, ethyl acetate and ethanol crude extracts, and the constituent 3,4-seco-friedelan-3-oic acid and 28,29-dihydroxyfriedelan-3-one showed in vitro antimicrobial activity against Salmonella typhimurium, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus cereus, Listeria monocytogenes, Streptococcus sanguinis and Candida albicans.

  13. Clinical validation of a nanodiamond-embedded thermoplastic biomaterial.

    Science.gov (United States)

    Lee, Dong-Keun; Kee, Theodore; Liang, Zhangrui; Hsiou, Desiree; Miya, Darron; Wu, Brian; Osawa, Eiji; Chow, Edward Kai-Hua; Sung, Eric C; Kang, Mo K; Ho, Dean

    2017-11-07

    Detonation nanodiamonds (NDs) are promising drug delivery and imaging agents due to their uniquely faceted surfaces with diverse chemical groups, electrostatic properties, and biocompatibility. Based on the potential to harness ND properties to clinically address a broad range of disease indications, this work reports the in-human administration of NDs through the development of ND-embedded gutta percha (NDGP), a thermoplastic biomaterial that addresses reinfection and bone loss following root canal therapy (RCT). RCT served as the first clinical indication for NDs since the procedure sites involved nearby circulation, localized administration, and image-guided treatment progress monitoring, which are analogous to many clinical indications. This randomized, single-blind interventional treatment study evaluated NDGP equivalence with unmodified GP. This progress report assessed one control-arm and three treatment-arm patients. At 3-mo and 6-mo follow-up appointments, no adverse events were observed, and lesion healing was confirmed in the NDGP-treated patients. Therefore, this study is a foundation for the continued clinical translation of NDs and other nanomaterials for a broad spectrum of applications. Published under the PNAS license.

  14. Application of multiphase modelling for vortex occurrence in vertical pump intake - a review

    International Nuclear Information System (INIS)

    Samsudin, M L; Munisamy, K M; Thangaraju, S K

    2015-01-01

    Vortex formation within pump intake is one of common problems faced for power plant cooling water system. This phenomenon, categorised as surface and sub-surface vortices, can lead to several operational problems and increased maintenance costs. Physical model study was recommended from published guidelines but proved to be time and resource consuming. Hence, the use of Computational Fluid Dynamics (CFD) is an attractive alternative in managing the problem. At the early stage, flow analysis was conducted using single phase simulation and found to find good agreement with the observation from physical model study. With the development of computers, multiphase simulation found further enhancement in obtaining accurate results for representing air entrainment and sub-surface vortices which were earlier not well predicted from the single phase simulation.The purpose of this paper is to describe the application of multiphase modelling with CFD analysis for investigating vortex formation for a vertically inverted pump intake. In applying multiphase modelling, there ought to be a balance between the acceptable usage for computational time and resources and the degree of accuracy and realism in the results as expected from the analysis. (paper)

  15. Application of multiphase modelling for vortex occurrence in vertical pump intake - a review

    Science.gov (United States)

    Samsudin, M. L.; Munisamy, K. M.; Thangaraju, S. K.

    2015-09-01

    Vortex formation within pump intake is one of common problems faced for power plant cooling water system. This phenomenon, categorised as surface and sub-surface vortices, can lead to several operational problems and increased maintenance costs. Physical model study was recommended from published guidelines but proved to be time and resource consuming. Hence, the use of Computational Fluid Dynamics (CFD) is an attractive alternative in managing the problem. At the early stage, flow analysis was conducted using single phase simulation and found to find good agreement with the observation from physical model study. With the development of computers, multiphase simulation found further enhancement in obtaining accurate results for representing air entrainment and sub-surface vortices which were earlier not well predicted from the single phase simulation. The purpose of this paper is to describe the application of multiphase modelling with CFD analysis for investigating vortex formation for a vertically inverted pump intake. In applying multiphase modelling, there ought to be a balance between the acceptable usage for computational time and resources and the degree of accuracy and realism in the results as expected from the analysis.

  16. Multiphase evolution of population and its application to optics and colliding-beam experiments

    International Nuclear Information System (INIS)

    Srinivasan, S.K.; Sridharan, V.

    1990-01-01

    In this paper we have analysed a multiphase evolution of population growth. Individual birth and immigration are assumed to be the consequence of the evolution of an individual through a sequence of phases whose duration form a family of independent non-negative random variables. The population model is then adapted to describe the evolution of photons in a cavity and, in particular, it is shown that a multiphase immigration model corresponds to the photons resulting from a stream obtained by amplitude mixing of coherent and chaotic beams. The model is also shown to bring out the characteristics of the multiplicity distribution of particles produced in high-energy collisions. (author)

  17. An open-source toolbox for multiphase flow in porous media

    Science.gov (United States)

    Horgue, P.; Soulaine, C.; Franc, J.; Guibert, R.; Debenest, G.

    2015-02-01

    Multiphase flow in porous media provides a wide range of applications: from the environmental understanding (aquifer, site-pollution) to industrial process improvements (oil production, waste management). Modeling of such flows involves specific volume-averaged equations and therefore specific computational fluid dynamics (CFD) tools. In this work, we develop a toolbox for modeling multiphase flow in porous media with OpenFOAM®, an open-source platform for CFD. The underlying idea of this approach is to provide an easily adaptable tool that can be used in further studies to test new mathematical models or numerical methods. The package provides the most common effective properties models of the literature (relative permeability, capillary pressure) and specific boundary conditions related to porous media flows. To validate this package, solvers based on the IMplicit Pressure Explicit Saturation (IMPES) method are developed in the toolbox. The numerical validation is performed by comparison with analytical solutions on academic cases. Then, a satisfactory parallel efficiency of the solver is shown on a more complex configuration.

  18. Multiphasic on/off pheromone signalling in moths as neural correlates of a search strategy.

    Directory of Open Access Journals (Sweden)

    Dominique Martinez

    Full Text Available Insects and robots searching for odour sources in turbulent plumes face the same problem: the random nature of mixing causes fluctuations and intermittency in perception. Pheromone-tracking male moths appear to deal with discontinuous flows of information by surging upwind, upon sensing a pheromone patch, and casting crosswind, upon losing the plume. Using a combination of neurophysiological recordings, computational modelling and experiments with a cyborg, we propose a neuronal mechanism that promotes a behavioural switch between surge and casting. We show how multiphasic On/Off pheromone-sensitive neurons may guide action selection based on signalling presence or loss of the pheromone. A Hodgkin-Huxley-type neuron model with a small-conductance calcium-activated potassium (SK channel reproduces physiological On/Off responses. Using this model as a command neuron and the antennae of tethered moths as pheromone sensors, we demonstrate the efficiency of multiphasic patterning in driving a robotic searcher toward the source. Taken together, our results suggest that multiphasic On/Off responses may mediate olfactory navigation and that SK channels may account for these responses.

  19. Multiphasic on/off pheromone signalling in moths as neural correlates of a search strategy.

    Science.gov (United States)

    Martinez, Dominique; Chaffiol, Antoine; Voges, Nicole; Gu, Yuqiao; Anton, Sylvia; Rospars, Jean-Pierre; Lucas, Philippe

    2013-01-01

    Insects and robots searching for odour sources in turbulent plumes face the same problem: the random nature of mixing causes fluctuations and intermittency in perception. Pheromone-tracking male moths appear to deal with discontinuous flows of information by surging upwind, upon sensing a pheromone patch, and casting crosswind, upon losing the plume. Using a combination of neurophysiological recordings, computational modelling and experiments with a cyborg, we propose a neuronal mechanism that promotes a behavioural switch between surge and casting. We show how multiphasic On/Off pheromone-sensitive neurons may guide action selection based on signalling presence or loss of the pheromone. A Hodgkin-Huxley-type neuron model with a small-conductance calcium-activated potassium (SK) channel reproduces physiological On/Off responses. Using this model as a command neuron and the antennae of tethered moths as pheromone sensors, we demonstrate the efficiency of multiphasic patterning in driving a robotic searcher toward the source. Taken together, our results suggest that multiphasic On/Off responses may mediate olfactory navigation and that SK channels may account for these responses.

  20. Antiferromagnetic-ferromagnetic crossover in UO2-TiOx multi-phase systems

    International Nuclear Information System (INIS)

    Nakamura, Akio; Tsutsui, Satoshi; Yoshii, Kenji

    2001-01-01

    An antiferromagnetic (AF)-weakly ferromagnetic (WF) crossover has been found for UO 2 -TiO x multi-phase systems, (1-y)UO 2 +yTiO x (y=0.05-0.72, x=0, 1.0, 1.5 and 2.0), when these mixtures are heat treated at high temperature in vacuum. From the powder X-ray diffraction and electron-microprobe analyses, their phase assemblies were as follows: for x=0, 1.0 and 1.5, a heterogeneous two-phase mixture of UO 2 +TiO x ; for x=2.0, that of UO 2 +UTi 2 O 6 for y 0.67 that of UTi 2 O 6 +TiO 2 (plus residual minor UO 2 ). Magnetic susceptibility (χ) of the present UO 2 powder was confirmed to exhibit an antiferromagnetic sharp drop at T N (=30.5 K). In contrast, χ of these multi-phase systems was found to exhibit a sharp upturn at the respective T N , while their T N values remained almost constant with varying y. This χ upturn at T N is most pronounced for UO 2 +Ti-oxide (titania) systems (x=1.0, 1.5 and 2.0) over the wide mixture ratio above y∼0.10. These observations indicate that an AF-WF crossover is induced for these multi-phase systems, plausibly due to the interfacial magnetic modification of UO 2 in contact with the oxide partners