WorldWideScience

Sample records for multielement analysis

  1. Thoughts on multielement analysis

    International Nuclear Information System (INIS)

    Kaiser, H.

    1976-01-01

    The author discusses, in an informal fashion, some of the important aspects of multielement analysis that are frequently overlooked in the present-day trend of trying to measure everything (elements, compounds) in everything (environmental samples). While many points are touched upon, with the aim of providing 'fuel' for the subsequent General Discussion, two themes are illustrated in some depth; do our backgrounds spoil our results, and do our experiments require the impossible A base for planning experimental strategy is outlined. (author)

  2. Multi-element analysis for environmental characterization and its future trends

    International Nuclear Information System (INIS)

    Sansoni, B.

    1987-04-01

    Before starting to characterize the environment by its elemental composition, it may be useful to ask about the objective of these efforts. This includes questions about the scope of environmental protection, the definition of the environment and the limitations of its characterization by elemental composition alone. In the second part of this lecture, examples are given of the elemental composition of well analysed samples from the atmosphere, hydrosphere, lithosphere and biosphere. The third part introduces the principle of multi-element analysis and the fourth part gives examples. Finally, future aspects of modern chemical analysis are outlined with respect to the multi-element principle. (orig.)

  3. Multi-element trace analysis of solid samples using one-photon two-step RIMS

    International Nuclear Information System (INIS)

    Telle, H. H.; Abraham, C. J.; Jones, O. R.; Krustev, T.

    1998-01-01

    In this study we have investigated the feasibility of multi-element analysis using a simple 1+1 photo-excitation/photo-ionization scheme. Although such schemes are usually far from ideal for optimum resonance ionization, they are the approach of choice if one wishes to maintain a simple, easy-to-operate laser set-up which is potentially suitable for routine analysis. In addition, we only made use of the second-harmonic tuning range of a single dye. While this limits the range of elements which are accessible in the 1+1 RIS scheme it further adds to the simplicity and allows for automation of sequential multi-element analysis

  4. Multielement neutron-activation analysis of plants and fertilizers

    International Nuclear Information System (INIS)

    Srapenyants, R.A.; Saveliev, I.B.

    1977-01-01

    The development of an automated technique for simultaneous multielement activation analysis of plants and fertilizers for the macronutrient elements N, P, K, Ca, Mg, Cl, and Si is presented. The developed universal NAA is based on the installation manufactured and supplied by Sames, France. The components of the automatic installation for neutron activation analysis are: neutron generator; a pneumatic transfer system; a scintillation crystal detector; a spectrometer rack including a basic multichannel analyser; a control panel for the neutron generator and pneumatic transfer system; a computer and teletype. On the basis of analytical procedures, algorithms and software, the first automatic (computer based) installation for multielement analyses of plants and fertilizers has been completed and is in routine use in the agrochemical and plant breeding research program in the Soviet Union. The proposed technique together with the full automatic real-time process of measurement and processing of data by computer, provides a throughput of 250-500 samples (1250-2500 elements determinations) per 8-hour shift, with the accuracy of +-3%; for N and +-5%; for P, K, Mg, Cl and +-15% for Ca. (T.G.)

  5. Multi-element analysis of unidentified fallen objects from Tatale in ...

    African Journals Online (AJOL)

    A multi-element analysis has been carried out on two fallen objects, # 01 and # 02, using instrumental neutron activation analysis technique. A total of 17 elements were identified in object # 01 while 21 elements were found in object # 02. The two major elements in object # 01 were Fe and Mg, which together constitute ...

  6. Validation of multi-element isotope dilution ICPMS for the analysis of basalts

    Energy Technology Data Exchange (ETDEWEB)

    Willbold, M.; Jochum, K.P.; Raczek, I.; Amini, M.A.; Stoll, B.; Hofmann, A.W. [Max-Planck-Institut fuer Chemie, Mainz (Germany)

    2003-09-01

    In this study we have validated a newly developed multi-element isotope dilution (ID) ICPMS method for the simultaneous analysis of up to 12 trace elements in geological samples. By evaluating the analytical uncertainty of individual components using certified reference materials we have quantified the overall analytical uncertainty of the multi-element ID ICPMS method at 1-2%. Individual components include sampling/weighing, purity of reagents, purity of spike solutions, calibration of spikes, determination of isotopic ratios, instrumental sources of error, correction of mass discrimination effect, values of constants, and operator bias. We have used the ID-determined trace elements for internal standardization to improve indirectly the analysis of 14 other (mainly mono-isotopic trace elements) by external calibration. The overall analytical uncertainty for those data is about 2-3%. In addition, we have analyzed USGS and MPI-DING geological reference materials (BHVO-1, BHVO-2, KL2-G, ML3B-G) to quantify the overall bias of the measurement procedure. Trace element analysis of geological reference materials yielded results that agree mostly within about 2-3% relative to the reference values. Since these results match the conclusions obtained by the investigation of the overall analytical uncertainty, we take this as a measure for the validity of multi-element ID ICPMS. (orig.)

  7. On multielement analysis of biological samples with the aid of neutron activation

    International Nuclear Information System (INIS)

    Iyengar, G.V.

    1980-01-01

    A main objective of this study was elucidation of problems of sampling and sample preparation methods for multielement analysis of environmental and biological specimens. Another was assessment of the potentials of multielement neutron activation analysis (NAA) in environmental and biological research. In an attempt to explain the great differences in the elemental concentration ranges between biopsy and autopsy samples as reported in the literature, it was shown that post mortem changes induce great variations in the apparent elemental composition of autopsy specimens resulting in serious systematic errors. Applications of NAA to analysis of tissues of experimental animals, human tissues in health and disease, and environmental samples are illustrated with several examples. The suitability of NAA for routine analysis of elements such as Cr, Mo and Se, which are difficult to determine by other methods has been specially discussed. (author)

  8. Multielement methods of atomic fluorescence analysis of enviromental samples

    International Nuclear Information System (INIS)

    Rigin, V.I.

    1985-01-01

    A multielement method of atomic fluorescence analysis of environmental samples based on sample decomposition by autoclave fluorination and gas-phase atomization of volatile compounds in inductive araon plasma using a nondispersive polychromator is suggested. Detection limits of some elements (Be, Sr, Cd, V, Mo, Te, Ru etc.) for different sample forms introduced in to an analyzer are given

  9. Provenance Establishment of Stingless Bee Honey Using Multi-element Analysis in Combination with Chemometrics Techniques.

    Science.gov (United States)

    Shadan, Aidil Fahmi; Mahat, Naji A; Wan Ibrahim, Wan Aini; Ariffin, Zaiton; Ismail, Dzulkiflee

    2018-01-01

    As consumption of stingless bee honey has been gaining popularity in many countries including Malaysia, ability to identify accurately its geographical origin proves pertinent for investigating fraudulent activities for consumer protection. Because a chemical signature can be location-specific, multi-element distribution patterns may prove useful for provenancing such product. Using the inductively coupled-plasma optical emission spectrometer as well as principal component analysis (PCA) and linear discriminant analysis (LDA), the distributions of multi-elements in stingless bee honey collected at four different geographical locations (North, West, East, and South) in Johor, Malaysia, were investigated. While cross-validation using PCA demonstrated 87.0% correct classification rate, the same was improved (96.2%) with the use of LDA, indicating that discrimination was possible for the different geographical regions. Therefore, utilization of multi-element analysis coupled with chemometrics techniques for assigning the provenance of stingless bee honeys for forensic applications is supported. © 2017 American Academy of Forensic Sciences.

  10. Procedures for multielement analysis using high-flux fast-neutron activation

    International Nuclear Information System (INIS)

    Williams, R.E.; Hopke, P.K.; Meyer, R.A.

    1981-06-01

    Improvements have been made in the rabbit system used for multi-element fast-neutron activation analysis at the Lawrence Livermore National Laboratory Rotating Target Neutron Source, RTNS-I. Procedures have been developed for the analysis of 20 to 25 elements in samples with an inorganic matrix and 10 to 15 elements in biological samples, without the need for prohibitively expensive, long irradiations. Results are presented for the analysis of fly ash, orchard leaves, and bovine liver

  11. Optimal acid digestion for multi-element analysis of different waste matrices

    DEFF Research Database (Denmark)

    Götze, Ramona; Astrup, Thomas Fruergaard

    of the distinct waste materials and recyclables. The purpose of this study is to evaluate the performance of different standardized microwave assisted acid digestion methods on waste samples and subsequent multi-element analysis. Six acid digestion methods were applied on a Paper & Cardboard and Composite waste...

  12. Multi-element determination in environmental samples by mass spectrometric isotope dilution analysis using thermal ionization. Pt. 2

    International Nuclear Information System (INIS)

    Hilpert, K.; Waidmann, E.

    1988-01-01

    An analytical procedure for the multi-element analysis of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Ba, Tl, and Pb in pine needles by mass spectrometric isotope dilution analysis using thermal ionization has been reported in Part I of this paper. This procedure is now transferred to the non-vegetable material 'Oyster Tissue' (Standard Reference Material 1566, National Bureau of Standards, USA). By a modification of the analytical procedure, it was possible to determine Cr in this material in addition to the aforementioned elements. No concentrations are certified for the elements Ga, Ba and Tl analyzed in this work. The concentrations of the remaining elements obtained by the multi-element analysis agree well with those certified. (orig.)

  13. Multi-element analysis of emeralds and associated rocks by k0 neutron activation analysis

    International Nuclear Information System (INIS)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B.

    2000-01-01

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k 0 method (k 0 INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method

  14. Multi-element analysis of emeralds and associated rocks by k{sub 0} neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B

    2000-12-15

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k{sub 0} method (k{sub 0} INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method.

  15. Simultaneous multi-element analysis of some edible pulses using neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Metwally, E.; Abdel-Khalik, H.

    2007-01-01

    This paper comprises the application of instrumental neutron activation analysis (INAA) for multi-element determination in some edible pulse samples. These edible pulses are usually daily used in the Egyptian kitchen. These were: anise, cumin, coriander, caraway, black cumin, white kidney bean, lupine, lentil, chickpea, broad bean, peanut, almond, and fenugreek. The pulses have been analyzed as dehulled pulses, in the case of legume and oil pulses with simultaneous analysis of their respective skins. The determined elements were: Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Th and Zn. The element content in the dehulled pulses and their respective skins has been compared. Some elements were major or minor elements where others were trace elements. Standard reference materials were used to assure quality control, accuracy and precision of the technique. (author)

  16. Multi-element neutron activation analysis and solution of classification problems using multidimensional statistics

    International Nuclear Information System (INIS)

    Vaganov, P.A.; Kol'tsov, A.A.; Kulikov, V.D.; Mejer, V.A.

    1983-01-01

    The multi-element instrumental neutron activation analysis of samples of mountain rocks (sandstones, aleurolites and shales of one of gold deposits) is performed. The spectra of irradiated samples are measured by Ge(Li) detector of the volume of 35 mm 3 . The content of 22 chemical elements is determined in each sample. The results of analysis serve as reliable basis for multi-dimensional statistic information processing, they constitute the basis for the generalized characteristics of rocks which brings about the solution of classification problem for rocks of different deposits

  17. Methodology for Design and Analysis of Reactive Distillation Involving Multielement Systems

    DEFF Research Database (Denmark)

    Jantharasuk, Amnart; Gani, Rafiqul; Górak, Andrzej

    2011-01-01

    A new methodology for design and analysis of reactive distillation has been developed. In this work, the elementbased approach, coupled with a driving force diagram, has been extended and applied to the design of a reactive distillation column involving multielement (multicomponent) systems...... consisting of two components. Based on this methodology, an optimal design configuration is identified using the equivalent binary-element-driving force diagram. Two case studies of methyl acetate (MeOAc) synthesis and methyl-tert-butyl ether (MTBE) synthesis have been considered to demonstrate...... the successful applications of the methodology. Moreover, energy requirements for various column configurations corresponding to different feed locatio...

  18. Multi-Element Composition of Honey as a Suitable Tool for Its Authenticity Analysis

    Directory of Open Access Journals (Sweden)

    Oroian Mircea

    2015-06-01

    Full Text Available The aim of this study was to evaluate the composition of 36 honey samples of 4 different botanical origins (acacia, sun flower, tilia and honeydew from the North East region of Romania. An inductively coupled plasma-mass spectrometry (ICP-MS method was used to determine 27 elements in honey (Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, K, Li, Mg, Mn, Na, Ni, Pb, Rb, Se, Sr, Tl, U, V and Zn. We would like to achieve the following goal: to demonstrate that the qualitative and quantitative multi-element composition determination of honey can be used as a suitable tool to classify honey according to its botanical origin. The principal component analysis allowed the reduction of the 27 variables to 2 principal components which explained 74% of the total variance. The dominant elements which were strongly associated with the principal component were K, Mg and Ca. Discriminant models obtained for each kind of botanical honey confirmed that the differentiation of honeys according to their botanical origin was mainly based on multi-element composition. A correct classification of all samples was achieved with the exception of 11.1% of honeydew honeys.

  19. The multielement potential of fast neutron cyclic activation analysis

    International Nuclear Information System (INIS)

    Nonie, S.E.; Randle, K.

    1994-01-01

    Cyclic neutron activation analysis (CNAA) has, in recent years been developed as a useful analytical tool for the assay of short-lived isotopes in single element situations. The work described in this paper investigates the potential of the technique for composite samples having a wide range of elements that produce short-lived and long-lived isotopes on neutron irradiation. Accelerator-derived neutrons with average energies of 3 MeV, 6 MeV and 14 MeV were employed in what has been dubbed 'Fast Neutron Cyclic Neutron Activation Analysis' (FNCAA). The approach to multi-element analysis entailed: determination of cycle parameters in single element samples via the reactions 27 Al(n,p) 27 Mg(9.6 min,E γ =840keV), and 137 Ba(n,n 'γ137m Ba(2.3 min,E γ 137m Ba(2.3 min,E γ =662 keV), a test of the method on a composite rock sample, determination of analytical sensitivities using both powdered kale and rock standards and a comparison of analytical results with other techniques. The results obtained in all these measurements are presented and discussed. (author) 10 refs.; 3 figs.; 5 tabs

  20. Multielement determination in some egyptian vegetables by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Tadros, N.A.; Abdel-Fattah, A.A.; Sanad, W.A.

    1999-01-01

    Nondestructive instrumental neutron activation analysis (INAA) technique, with thermal neutrons, has been applied for multielement determination of major, trace and ultra trace elements in eleven types of the public public egyptian, edible vegetables, namely dill, moulokhyia, okra negro bean, parsley, green pea, grape leaves, spinach, mint, celery and salad chervil, cultivated and collected from El-Maadi, Cairo, E G. Concentrations of Na, K, Ca, Sc, Cr, Fe, Co, Ni, Zn, Rb, Zr, Nb, Mo, Sb, Cs, Ba, La, Ce, Tb, Yb, Hf, Ta, Th and U were determined. The standard reference materials (SRM's) G-2, J G-1 and MAG-1, provided from IAEA, were used, and high accuracy of the work was assured. The results were discussed

  1. Suitability of NAA for certification of reference materials for multielements

    International Nuclear Information System (INIS)

    Tian Weizhi; Ni Bangfa; Wang Pingsheng; Nie Huiling

    2000-01-01

    Certifications of trace elements in existing CRMs, especially biological CRMs, are far from satisfactory. Neutron activation analysis (NAA) for its inherent advantages combined with newly established parametric standardization, may contribute to improve this situation. The continuing progress of the hybrid extended k 0 -relative NAA technique developed in our laboratory is discussed. Examples are given to show the reliability of the method in certification of multielements. RNAA is still one of the best methods, or even the method of choice, in analysis at sub-μg/g concentration levels. The suitability of the technique for this purpose has been studied through the determination of rare earth elements at ng/g concentration level in two Chinese biological CRMs using both RNAA and ICPMS. Sampling behaviors of multielements in CRMs have been studied by INAA in an effort to develop CRMs suitable for analysis with small sample sizes. (author)

  2. Multi-element analysis of crude-oil samples by 14.6 MeV neutron activation

    International Nuclear Information System (INIS)

    Cam, N.F.; Cigeroglu, F.; Erduran, M.N.

    1997-01-01

    The instrumental neutron activation technique, using the SAMEST T-400 neutron generator with 14.6 MeV neutrons produced from 3 H(d,n) 4 He reaction, is demonstrated for multi-element analysis of Saudi-Arabian crude-oil samples. The system parameters for the absolute method (e.g., the counting solid-angle, intrinsic efficiency of the γ-ray detector, effective neutron flux, activation cross sections, etc.)were determined and the results of elemental concentrations were presented with the corrections for all possible interferences having been carefully considered. (author)

  3. Detailed Modeling and Irreversible Transfer Process Analysis of a Multi-Element Thermoelectric Generator System

    Science.gov (United States)

    Xiao, Heng; Gou, Xiaolong; Yang, Suwen

    2011-05-01

    Thermoelectric (TE) power generation technology, due to its several advantages, is becoming a noteworthy research direction. Many researchers conduct their performance analysis and optimization of TE devices and related applications based on the generalized thermoelectric energy balance equations. These generalized TE equations involve the internal irreversibility of Joule heating inside the thermoelectric device and heat leakage through the thermoelectric couple leg. However, it is assumed that the thermoelectric generator (TEG) is thermally isolated from the surroundings except for the heat flows at the cold and hot junctions. Since the thermoelectric generator is a multi-element device in practice, being composed of many fundamental TE couple legs, the effect of heat transfer between the TE couple leg and the ambient environment is not negligible. In this paper, based on basic theories of thermoelectric power generation and thermal science, detailed modeling of a thermoelectric generator taking account of the phenomenon of energy loss from the TE couple leg is reported. The revised generalized thermoelectric energy balance equations considering the effect of heat transfer between the TE couple leg and the ambient environment have been derived. Furthermore, characteristics of a multi-element thermoelectric generator with irreversibility have been investigated on the basis of the new derived TE equations. In the present investigation, second-law-based thermodynamic analysis (exergy analysis) has been applied to the irreversible heat transfer process in particular. It is found that the existence of the irreversible heat convection process causes a large loss of heat exergy in the TEG system, and using thermoelectric generators for low-grade waste heat recovery has promising potential. The results of irreversibility analysis, especially irreversible effects on generator system performance, based on the system model established in detail have guiding significance for

  4. Multielement analysis of water in the Yodo River

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Mizohata, Akira; Matsunami, Tadao; Matsuda, Yatsuka

    1979-01-01

    In 1970 we made multielement analysis of water samples collected at various points in the Yodo River, which is the main source of tap water supply in Osaka district, in order to know the extent of pollution especially by metallic elements. The analytical results were discussed from the standpoint of the material balance. In 1977 we again made a similar survey; the number of sampling points was increased. It was revealed that the pollution pattern was quite similar to that found formerly, but concentrations of the elements originating mainly from human activities somewhat decreased. The material balance was discussed in greater detail. It was attempted to explain the change of the elemental concentrations along the stream, taking into consideration the flow-in from small brooks and the take-out by water purification plants. In the down stream where the flow speed is very low, the concentrations of the elements originating mainly from soil was considerably low possibly due to the precipitation of particulates, and the concentrations of the soluble elements originating from human activities was also somewhat low possibly because of the take-out of relatively more polluted water by purification plants. (author)

  5. Multielement suppressor nozzles for thrust augmentation systems.

    Science.gov (United States)

    Lawrence, R. L.; O'Keefe, J. V.; Tate, R. B.

    1972-01-01

    The noise reduction and nozzle performance characteristics of large-scale, high-aspect-ratio multielement nozzle arrays operated at low velocities were determined by test. The nozzles are selected for application to high-aspect-ratio augmentor suppressors to be used for augmentor wing airplanes. Significant improvements in noise characteristics for multielement nozzles over those of round or high-aspect-ratio slot nozzles are obtained. Elliptical noise patterns typical of slot nozzles are presented for high-aspect-ratio multielement nozzle arrays. Additional advantages are available in OASPL noise reduction from the element size and spacing. Augmentor-suppressor systems can be designed for maximum beam pattern directivity and frequency spectrum shaping advantages. Measurements of the nozzle wakes show a correlation with noise level data and frequency spectrum peaks. The noise and jet wake results are compared with existing prediction procedures based on empirical jet flow equations, Lighthill relationships, Strouhal number, and empirical shock-induced screech noise effects.

  6. Application of the multi-element analysis by X-fluorescence and neutron activation to the characterization of an archaeological site

    International Nuclear Information System (INIS)

    Rossini, I.

    1991-06-01

    The first part of this thesis is about possible analysis methods (XRF, PIXE, INAA, laser fluorimetry, and ICP), applied to Uranium, Thorium and Rubidium assays in archaeological clays and potteries. The best results have been obtained with Neutron Activation technics. The second part is about the multi-element analysis of quarries and about the research by statistical treatment of correlations between the element concentrations and the sampling sites (excavations, quarries)

  7. Multi-element probabilistic collocation method in high dimensions

    International Nuclear Information System (INIS)

    Foo, Jasmine; Karniadakis, George Em

    2010-01-01

    We combine multi-element polynomial chaos with analysis of variance (ANOVA) functional decomposition to enhance the convergence rate of polynomial chaos in high dimensions and in problems with low stochastic regularity. Specifically, we employ the multi-element probabilistic collocation method MEPCM and so we refer to the new method as MEPCM-A. We investigate the dependence of the convergence of MEPCM-A on two decomposition parameters, the polynomial order μ and the effective dimension ν, with ν<< N, and N the nominal dimension. Numerical tests for multi-dimensional integration and for stochastic elliptic problems suggest that ν≥μ for monotonic convergence of the method. We also employ MEPCM-A to obtain error bars for the piezometric head at the Hanford nuclear waste site under stochastic hydraulic conductivity conditions. Finally, we compare the cost of MEPCM-A against Monte Carlo in several hundred dimensions, and we find MEPCM-A to be more efficient for up to 600 dimensions for a specific multi-dimensional integration problem involving a discontinuous function.

  8. Determination of trace metals in coastal seawater around Okinawa and its multielement profiling analysis

    International Nuclear Information System (INIS)

    Itoh, Akihide; Ishigaki, Teruyuki; Arakaki, Teruo; Yamada, Ayako; Yamaguchi, Mami; Kabe, Noriko

    2009-01-01

    In the present study, trace metals in coastal surface seawater around Okinawa were determined by inductively coupled plasma mass spectrometry (ICP-MS) with chelating disk preconcentration. As a result, the concentrations of V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U were obtained in the range from 10 μgL -1 to 0.001 μgL -1 for 6 samples. In addition, multielement profiling analyses were carried out using analytical values obtained in order to elucidate the features of trace metals in each coastal sea area. For coastal surface seawater near an urban area, the analytical values for Zn, Cu, Mn, and Pb were higher by more than 10-fold the literature values for open-surface seawater, and those of Cd were also relatively high. Such a trend concerning the multi-element profile was almost similar to the literature values for coastal seawater of the main island of Japan. On the other hand, the analytical values of most elements for coastal surface seawater near a suburb area were in the range from 0.5 to 5 fold, compared to the literature values for open surface seawater. From multielement profiling analyses for nutrient type elements in marine chemistry, it was suggested that the concentrations of Zn and Cd in a coral sea area normalized to literature values for open surface-seawater were higher than those of Ni and Cu. (author)

  9. Simultaneous multielement analysis of zirconium alloys by chlorination separation of matrix/ICP-AES

    International Nuclear Information System (INIS)

    Kato, Kaneharu

    1990-01-01

    An analytical method combined chlorination separation of matrix with ICP-AES has been developed for reactor grade Zr alloys (Zircaloy-2). A sample (1 g) is taken into a Pt boat and chlorinated with HCl gas of 100 ml/min in a glass reaction tube at ca. 330degC. Matrix Zr of the sample is volatilized and separated as ZrCl 4 . The analytic elements remaining quantitatively as chlorination residue are dissolved in a mixture of mineral acids (6 M HCl 3 ml+conc. HNO 3 0.5 ml+conc. H 2 SO 4 0.2 ml) and diluted to 20 ml with distilled water after filtration. ICP-AES was used for simultaneous multielement determination using a calibration curve method. The present method has the following advantages: simple sample preparation procedure; applicability to any form of samples to determine multielements; simple ICP-AES calibration procedure. This method was successfully applied to the determination of Fe, Ni, Cu, Co, Mn and Pb in the Zr alloys of JAERI CRM's and NBS SRM's. (author)

  10. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  11. Wideband multi-element Er-doped fiber amplifier

    International Nuclear Information System (INIS)

    Thipparapu, N K; Jain, S; May-Smith, T C; Sahu, J K

    2014-01-01

    A multi-element Er-doped fiber amplifier (MEEDFA) is demonstrated in which the gain profile is extended into the S and L bands. Each fiber element of the MEEDFA is found to provide a maximum gain of 37 dB and a noise figure of < 4 dB in the C-band. The gain profile of the amplifier is shifted towards longer wavelength by cascading fiber elements. The novel geometry of the multi-element fiber (MEF) could allow for the development of a broadband amplifier in a split-band configuration. The proposed amplifier can operate in the wavelength band of 1520 to 1595 nm (75 nm), with a minimum gain of 20 dB. (letter)

  12. Multi-element neutron activation analysis of biological tissues: contribution to the study of trace element accumulation as a function of aging

    International Nuclear Information System (INIS)

    Gaudry, Andre.

    1975-01-01

    The accumulation of trace elements in various organs as a function of age was studied in rats, in connection with tissue aging phenomena. Part one reviews the various methods available to develop a programme of simultaneous multi-element analysis in biological matrices. Part two studies the precision and accuracy offered by neutron activation analysis. Special attention is paid to the problem of sample contamination by the silica glass irradiation supports. The possible causes of this effect are mentioned and a procedure limiting its harmful influence is proposed. Part three defines the restrictions introduced by the use of a method to separate the activable matrix. The fourth and last chapter describes the development of a multielement chemical separation system, designed to work semi-automatically for the simultaneous treatment of three samples and a standard in a shielded cell of small dimensions. The principles of a multi-comparator calibration where a knowledge of certain conventional but imprecise nuclear data is unnecessary owing to an experimental expedient are outlined briefly. Finally the separation method is tried out on various biological samples, including a reference (bovine liver SRM1577-NBS), and some results are given [fr

  13. Characterisation of synthetic multi-element standards (SMELS) used for the validation of k(o)-NAA

    Czech Academy of Sciences Publication Activity Database

    Vermaercke, P.; Robouch, P.; Eguskiza, M.; De Corte, F.; Kennedy, G.; Smodiš, B.; Jaćimović, R.; Yonezawa, C.; Matsue, H.; Lin, X.; Blaauw, M.; Kučera, Jan

    2006-01-01

    Roč. 564, č. 2 (2006), s. 675-682 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10480505 Keywords : neutron activation analysis * ko-standardization * multi-element standard Subject RIV: CB - Analytical Chemistry, Separation

  14. A New Multielement Method for LA-ICP-MS Data Acquisition from Glacier Ice Cores.

    Science.gov (United States)

    Spaulding, Nicole E; Sneed, Sharon B; Handley, Michael J; Bohleber, Pascal; Kurbatov, Andrei V; Pearce, Nicholas J; Erhardt, Tobias; Mayewski, Paul A

    2017-11-21

    To answer pressing new research questions about the rate and timing of abrupt climate transitions, a robust system for ultrahigh-resolution sampling of glacier ice is needed. Here, we present a multielement method of LA-ICP-MS analysis wherein an array of chemical elements is simultaneously measured from the same ablation area. Although multielement techniques are commonplace for high-concentration materials, prior to the development of this method, all LA-ICP-MS analyses of glacier ice involved a single element per ablation pass or spot. This new method, developed using the LA-ICP-MS system at the W. M. Keck Laser Ice Facility at the University of Maine Climate Change Institute, has already been used to shed light on our flawed understanding of natural levels of Pb in Earth's atmosphere.

  15. Simultaneous multi-element determination in different seed samples of Dodonaea viscosa hopseed using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, Fatma H.; El-Amir, Mahmoud A.; Mostafa, Mohamed; Ramadan, Hala E.; Rashad, Ghada M.

    2016-01-01

    Instrumental neutron activation analysis technique (INAA) was applied for nondestructive multi-element analysis of seed samples of the plant Dodonaea viscosa hopseed. This plant is distributed all over Egypt, because of its suitable properties. The samples were collected from some bushes grown at different sites in some governorates, in July of each year during the period from 2004 to 2011. The determined elements are: Co, Cs, Eu, Fe, Hg, Ni, Rb, Sc, Se, Sr and Zn, under the chosen irradiation and cooling times. The content of some elements has been compared with data obtained from previous work on analysis of various kinds of seeds. The influence of some parameters on the determined elemental content is discussed. Standard reference materials IAEA-155 and IAEA-V-10 were used to assure quality control, accuracy and precision of the technique.

  16. Simultaneous multi-element determination in different seed samples of Dodonaea viscosa hopseed using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, Fatma H.; El-Amir, Mahmoud A.; Mostafa, Mohamed; Ramadan, Hala E.; Rashad, Ghada M. [Atomic Energy Authority, Cairo (Egypt). Hot Lab. Center

    2016-07-01

    Instrumental neutron activation analysis technique (INAA) was applied for nondestructive multi-element analysis of seed samples of the plant Dodonaea viscosa hopseed. This plant is distributed all over Egypt, because of its suitable properties. The samples were collected from some bushes grown at different sites in some governorates, in July of each year during the period from 2004 to 2011. The determined elements are: Co, Cs, Eu, Fe, Hg, Ni, Rb, Sc, Se, Sr and Zn, under the chosen irradiation and cooling times. The content of some elements has been compared with data obtained from previous work on analysis of various kinds of seeds. The influence of some parameters on the determined elemental content is discussed. Standard reference materials IAEA-155 and IAEA-V-10 were used to assure quality control, accuracy and precision of the technique.

  17. Multielement comparison of instrumental neutron activation analysis techniques using reference materials

    International Nuclear Information System (INIS)

    Ratner, R.T.; Vernetson, W.G.

    1995-01-01

    Several instrumental neutron activation analysis techniques (parametric, comparative, and k o -standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g. insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications. (author) 4 refs.; 2 tabs

  18. Quantification of multielement-multilayer-samples in electron probe analysis

    International Nuclear Information System (INIS)

    Pfeiffer, A.

    1995-03-01

    The following dissertation presents the theoretical basis of analytical correction models and Monte Carlo simulations in the field of electron probe microanalysis to describe the excitation conditions of x-rays in a multilayer-multielement-sample. In this connection analyzing programs have been developed to make a quantitative investigation of heterogeneous samples possible. In the work the mathematical methods and formulas, which are mainly based on empirical and semiempirical findings, are described and their validity is discussed in detail. Especially the improvements of the 'multiple reflections'-model by August are compared with the Φ(ρz)-models by Pouchou, Merlet and Bastin. The calculations of depth distribution functions for characteristics and continuous fluorescence excitation result in a consistent and completeΦ(ρz)-model. This allows to analyze layered structures in great detail. Because of the increasing importance in electron probe microanalysis and as a reference method a Monte Carlo model is described. With this model electron trajectories and excitation conditions in arbitrary two dimensional geometries can be calculated. The validity of the analytical model is proven with a comprehensive comparison of results of new calculations to published data. To show an application of the programs and models in routine use in the industrial research and development, a quantitative analysis of a Co/Si system is made. In the conclusion of this dissertation some reflections upon investigations, which are based on this work and which should be made in future are outlined. (author)

  19. Simultaneous multi-element atomic absorption system using photodiode array detector

    International Nuclear Information System (INIS)

    Tong, S.L.; Chin, K.S.

    1994-01-01

    A photodiode array (PDA) detector-multichannel analyser (MCA) system has been coupled to a flame and a graphite furnace atomiser and tested for simultaneous multielement atomic absorption analysis. Multielement hollow cathode lamps (HCL) are used as light source. Spectral lines are dispersed through a spectrograph with triple gratings and detected by a 25.4 mm PDA detector consisting of 1024 elements. The optical MCA system is capable of recording multiple spectra spanned by the spectrograph/PDA. The transmitted intensity spectra obtained for the standard and analyte solutions during flame or graphite furnace atomisation are converted to absorbance spectra using the MCA software provided. Results from the comparison studies show that the linear range and sensitivities for Ni-Co-Fe and Cu-Cr obtained from the simultaneous measurements are within the same order of magnitudes as those from conventional single element determinations using photomultiplier tube detection. The study also shows that non-atomic absorption can be readily corrected by a two-line method where non-atomic absorption lines can be chosen from the spectra recorded simultaneously. The proposed system has been evaluated for the determination of trace elements using NBS standard reference water SRM 1643b

  20. Multi-element analysis of lubricant oil by WDXRF technique using thin-film sample preparation

    International Nuclear Information System (INIS)

    Scapin, M. A.; Salvador, V. L. R.; Lopes, C. D.; Sato, I. M.

    2006-01-01

    The quantitative analysis of the chemical elements in matrices like oils or gels represents a challenge for the analytical chemists. The classics methods or instrumental techniques such as atomic absorption spectrometry (AAS) and plasma optical emission spectrometry (ICP-OES) need chemical treatments, mainly sample dissolution and degradation processes. X-ray fluorescence technique allows a direct and multi-element analysis without previous sample treatments. In this work, a sensible method for the determination of elements Mg, Al, Si, P, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Mo, Ag, Sn, Ba and Pb in lubricating oil is presented. The x-ray fluorescence (WDXRF) technique using linear regression method and thin film sample preparation was used. The validation of the methodology (repeatability and accuracy) was obtained by the analysis of the standard reference materials SRM Alpha AESAR lot 703527D, applying the Chauvenet, Cochrane, ANOVA and Z-score statistical tests. The method presents a relative standard deviation lower than 10% for all the elements, except for Pb determination (RSD Pb 15%). The Z-score values for all the elements were in the range -2 < Z < 2, indicating a very good accuracy.(Full text)

  1. Multielement analysis of human hair and kidney stones by instrumental neutron activation analysis with the k0-standardization method

    International Nuclear Information System (INIS)

    Abugassa, I.; Sarmani, S.B.; Samat, S.B.

    1999-01-01

    This paper focuses on the evaluation of the k 0 method of instrumental neutron activation analysis in biological materials. The method has been applied in multielement analysis of human hair standard reference materials from IAEA, No. 085, No. 086 and from NIES (National Institute for Environmental Sciences) No. 5. Hair samples from people resident in different parts of Malaysia, in addition to a sample from Japan, were analyzed. In addition, human kidney stones from members of the Malaysian population have been analyzed for minor and trace elements. More than 25 elements have been determined. The samples were irradiated in the rotary rack (Lazy Susan) at the TRIGA Mark II reactor of the Malaysian Institute for Nuclear Technology and Research (MINT). The accuracy of the method was ascertained by analysis of other reference materials, including 1573 tomato leaves and 1572 citrus leaves. In this method the deviation of the 1/E 1+α epithermal neutron flux distribution from the 1/E law (P/T ratio) for true coincidence effects of the γ-ray cascade and the HPGe detector efficiency were determined and corrected for

  2. Procedural and developmental aspects of a multielement automatic radiochemical machine, applied to neutron irradiated biomedical samples

    International Nuclear Information System (INIS)

    Iyengar, G.V.

    1976-06-01

    This report is intended to serve as a practical guide, elaborately describing the working details and some developmental work connected with an automatic multielement radiochemical machine based on thermal neutron activation analysis using ion exchange and partition chromatography. Some of the practical aspects and personal observations after much experience with this versatile multielement method, applied to investigate the elemental composition of different biomedical matrices, are summarized. Standard reference materials are analyzed, and the data are presented with a set of gamma-spectra obtained before and after chemical separation into convenient groups suitable for gamma spectroscopy. The samples analyzed included various human and animal tissues, body fluids, IAEA biological standard reference materials, and samples from the WHO/IAEA project on 'Trace elements in relation to cardiovascular diseases'. Simplified modifications of the radiochemical processing, suitable for fast and routine analysis of clinical samples have also been discussed. (orig.) [de

  3. Wear And Tear Determination By Trace Multi-Element Analysis Of An Unused And Used Lubricant Oil Using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Adeyemo, D.J.

    2004-01-01

    Instrumental neutron activation analysis technique using the Imperial College Centre consort M. K. II nuclear reactor was utilized for the determination of: As, Ba Ca CI, Co, Cr, Cu, Fe, K, Mn, Mo, Na Ni, Rb, Sb, Se, Ti, V, and Zn, in an imported and used car lubricant oil. The wear of the oil lubricated parts of the car engine was monitored by establishing a correlation between the results obtained in the analysis. The result obtained from the analysis of the unused and then used samples on a low performing oil leaking four stroke car engine showed an increase on all the elements determined except for Se and Rb. The precision for the multi-element analysis is less than 12% for most of the elements. The accuracy of the measurement is also validated by the result obtained from the analysis of NBS-SRM1635 (sub-bituminous) coal standard for the elements. The results obtained indicate that analysis of unused and used lubricant oil samples can aid in locating defects in engine parts and hence facilitated maintenance procedures

  4. Integrated Process Design and Control of Multi-element Reactive Distillation Processes

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil; Sales-Cruz, Mauricio; Huusom, Jakob Kjøbsted

    2016-01-01

    In this work, integrated process design and control of reactive distillation processes involving multi-elements is presented. The reactive distillation column is designed using methods and tools which are similar in concept to non-reactive distillation design methods, such as driving force approach....... The methods employed in this work are based on equivalent element concept. This concept facilitates the representation of a multi-element reactive system as equivalent binary light and heavy key elements. First, the reactive distillation column is designed at the maximum driving force where through steady...

  5. Energy spectra of gold and silver ions jointly expanding in multielement laser plasma

    International Nuclear Information System (INIS)

    Bedilov, M.R.; Kuramatov, D.; Tsoj, T.G.; Kholbaev, A.; Khaitbaev, K.

    1986-01-01

    The results of the investigations on energy distribution of Au and Ag ions jointly expanding in multielement paser plasma are presented. It is denonstrated, that on the stages of formation and expanding of multielement plasma multucharged ions considerable contribution is made by collision processes between electrons and ions and between ions of light and heavy elements. The results are discussed on the basis of existing theoretical models

  6. Multi-Element Lean Direct Injection Combustor Module, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a Multi-Element Lean Direct Injection, ME-LDI, Combustion concept with the following innovative features: 1. Independent, mini burning zones...

  7. Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects

    Directory of Open Access Journals (Sweden)

    Ziho Kang

    2016-01-01

    Full Text Available Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1 participants interrogate dynamic multielement objects that can overlap on the display and (2 visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1 developing dynamic areas of interests (AOIs in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2 introducing the concept of AOI gap tolerance (AGT that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3 finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC operations where air traffic controller specialists (ATCSs interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance.

  8. Nondestructive multielement analyses of airborne particulates by combined uses of instrumental neutron activation analysis and energy dispersive X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1974-01-01

    Combined uses of instrumental neutron activation analysis and energy dispersive X-ray fluorescence analysis make it possible to analyze nondestructively a considerably large number of elements in airborne particulates. We have confirmed that up to 45 elements can be analyzed without any chemical procedures for urban airborne particulate samples. As the radiation spectrometry by semiconductor detectors and the automatic data reduction by electronic computation are quite common to the two techniques, combined uses of them produce no special annoyance. Several elements can be analyzed by both of them and therefore the reliability of the analytical results can be comfirmed by comparing the data obtained by them with each other. It is noted that this confirmation can be made for the very same sample. In this article are described our experiences of multielement analyses of airborne particulates and some problems to be solved in further studies. (auth.)

  9. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2007-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  10. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2008-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  11. A study of possibility of application of instrumental NNA for multielement large-scale analysis of materials important for ecology and geology; Rozpoznanie mozliwosci zastosowania instrumentalnej wersji NNA do wielopierwiastkowej analizy duzych serii materialow waznych z punktu widzenia ekologii i geologii

    Energy Technology Data Exchange (ETDEWEB)

    Wasek, M.; Szopa, Z.; Dybczynski, R.

    1997-12-31

    A general scheme of INAA used in the Laboratory of Radiometric Methods of the INCT as well as present status of equipment and software serving for processing and interpretation of gamma-ray spectra have been presented. Sequential stages of multielement analysis were described, especially those were potential systematic and random errors that might affect the analysis reliability could be expected. Conclusions estimating the possibilities of INNA analyses carried out at present conditions have been drawn as well as future needs concerning both equipment and software serving for large-scale multielement routine analyses have been pointed out. (author). 13 refs, 5 figs, 3 tabs.

  12. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  13. Laser ablation-inductively coupled plasma-dynamic reaction cell-mass spectrometry for the multi-element analysis of polymers

    International Nuclear Information System (INIS)

    Resano, M.; Garcia-Ruiz, E.; Vanhaecke, F.

    2005-01-01

    In this work, the potential of laser ablation-inductively coupled plasma-mass spectrometry for the fast analysis of polymers has been explored. Different real-life samples (polyethylene shopping bags, an acrylonitrile butadiene styrene material and various plastic bricks) as well as several reference materials (VDA 001 to 004, Cd in polyethylene) have been selected for the study. Two polyethylene reference materials (ERM-EC 680 and 681), for which a reference or indicative value for the most relevant metals is available, have proved their suitability as standards for calibration. Special attention has been paid to the difficulties expected for the determination of Cr at the μg g -1 level in this kind of materials, due to the interference of ArC + ions on the most abundant isotopes of Cr. The use of ammonia as a reaction gas in a dynamic reaction cell is shown to alleviate this problem, resulting in a limit of detection of 0.15 μg g -1 for this element, while limiting only modestly the possibilities of the technique for simultaneous multi-element analysis. In this regard, As is the analyte most seriously affected by the use of ammonia, and its determination has to be carried out in vented mode, at the expense of measuring time. In all cases studied, accurate results could be obtained for elements ranging in content from the sub-μg g -1 level to tens of thousands of μg g -1 . However, the use of an element of known concentration as internal standard may be needed for materials with a matrix significantly different from that of the standard (polyethylene in this work). Precision ranged between 5% and 10% RSD for elements found at the 10 μg g -1 level or higher, while this value could deteriorate to 20% for analytes found at the sub-μg g -1 level. Overall, the technique evaluated presents many advantages for the fast and accurate multi-element analysis of these materials, avoiding laborious digestion procedures and minimizing the risk of analyte losses due to the

  14. Laser ablation inductively coupled plasma dynamic reaction cell mass spectrometry for the multi-element analysis of polymers

    Science.gov (United States)

    Resano, M.; García-Ruiz, E.; Vanhaecke, F.

    2005-11-01

    In this work, the potential of laser ablation-inductively coupled plasma-mass spectrometry for the fast analysis of polymers has been explored. Different real-life samples (polyethylene shopping bags, an acrylonitrile butadiene styrene material and various plastic bricks) as well as several reference materials (VDA 001 to 004, Cd in polyethylene) have been selected for the study. Two polyethylene reference materials (ERM-EC 680 and 681), for which a reference or indicative value for the most relevant metals is available, have proved their suitability as standards for calibration. Special attention has been paid to the difficulties expected for the determination of Cr at the μg g - 1 level in this kind of materials, due to the interference of ArC + ions on the most abundant isotopes of Cr. The use of ammonia as a reaction gas in a dynamic reaction cell is shown to alleviate this problem, resulting in a limit of detection of 0.15 μg g - 1 for this element, while limiting only modestly the possibilities of the technique for simultaneous multi-element analysis. In this regard, As is the analyte most seriously affected by the use of ammonia, and its determination has to be carried out in vented mode, at the expense of measuring time. In all cases studied, accurate results could be obtained for elements ranging in content from the sub-μg g - 1 level to tens of thousands of μg g - 1 . However, the use of an element of known concentration as internal standard may be needed for materials with a matrix significantly different from that of the standard (polyethylene in this work). Precision ranged between 5% and 10% RSD for elements found at the 10 μg g - 1 level or higher, while this value could deteriorate to 20% for analytes found at the sub-μg g - 1 level. Overall, the technique evaluated presents many advantages for the fast and accurate multi-element analysis of these materials, avoiding laborious digestion procedures and minimizing the risk of analyte losses due

  15. Statistical Methods in Assembly Quality Management of Multi-Element Products on Automatic Rotor Lines

    Science.gov (United States)

    Pries, V. V.; Proskuriakov, N. E.

    2018-04-01

    To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.

  16. Multielement analysis of reagents used in chemical identification of transuranic elements

    International Nuclear Information System (INIS)

    Montalvan Estrada, A.; Brigido Flores, O.; Maslov, O.D.; Dmitriev, S.N.

    2006-01-01

    For more than 40 years, chemical identification of transuranic elements has been used at the Laboratory of Nuclear Reactions of the Join Institute for Nuclear Research, Dubna, Russia, as a secondary method of identification. Chlorination of transuranic elements obtained by nuclear reactions is an important step of the procedure in order to obtain volatile compounds able to pass through a thermo chromatographic process. To access the quality of the reagents TiCl 4 and SOCl 2 multielement analysis was carried out using both X-rays fluorescence and gamma activation. It was followed the simplest procedure for reagents samples pretreatment, so further interferences from other chemical products were avoided. X-rays fluorescence analysis was performed in a spectrometer with Si(Li) detector with a resolution for Fe (K?) of 190 eV. Both Cd-109 and Am-241 were used as isotopic sources of excitation. Gamma activation analysis was carried out using the compact electron accelerator MT-25, where gamma rays are produced in a stopping target. Among the parameters of the MT-25 are the following: energy range-10-25 MeV, gamma-ray flux-10 14 photon/s, power consumption-20 kw. Measurements of the induced activity were performed with the help of a HPGe detector, thin and coaxial Ge(Li) detectors. There were identified two elements in SOCl 2 -Nickel (3*10 -6 g/g) and Antimony (2*10 -7 g/g), while there were identified three elements in TiCl 4 - Zirconium (8*10 -7 g/g), Arsenic (9*10 -7 g/g) and Antimony (5*10 -7 g/g). Only five elements were detected in trace concentrations in the two analyzed reagents, that is for more than 57 elements capable of being detected using gamma activation analysis with the MT-25 only 5 had concentrations above the detection limits of the method. Not being chemical analogs of the synthesized transuranic elements (Z-104 and 106) and not being able to alpha or fission disintegrations there is not expected any interference from them in the chemical

  17. Multielement fingerprinting for characterization: Earthworm samples from the environmental specimen bank of the FRG

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1988-01-01

    Earthworm samples (Lumbricidae) from three different sampling sites in the Federal Republic of Germany were collected for the German Environmental Specimen Bank (ESB). Subsamples of the cryohomogenized material from two annual samplings were analyzed by Instrumental Neutron Activation Analysis (INAA) and mean values are presented in the logarithmic fingerprint mode. The 'identical matrix reference material concept' of the ESB has been applied and proved to be of particular value for multielement determinations. (orig.)

  18. Characterization of sampling behavior for multielements in NIST SRM 2703

    International Nuclear Information System (INIS)

    Huang Donghui; Sun Hongchao; Ni Bangfa; Tian Weizhi; Wang Pingsheng; Liu CunXiong; Zhang Guiying; Xiao Caijin; Zhang Haiqing; Zhao Changjun; Zhang Yuanxun

    2011-01-01

    Sampling behavior of multielements for NIST SRM 2703, a marine sediment, was studied with sample sizes from 1 mg down to ng level by a combination of INAA, PIXE and SRXRF. On 1 mg sample size level, sampling behavior for multielements in NIST SRM 2703 and its parent SRM 2702 were comparatively characterized by using INAA combining with Ingamells model. Results showed that sampling uncertainties for 12 elements of both materials were found to be better than 1%, and those of four other elements in SRM 2703 better than in SRM 2702. At sample sizes not able to be accurately weighed (<1 mg), PIXE and SRXRF were used and the effective sample sizes estimated. Sampling uncertainties for nine elements were found to be better than 1% at sample sizes of tenth mg level, and those for six elements better than 10% on ng levels. (author)

  19. Multi-Element Analysis and Geochemical Spatial Trends of Groundwater in Rural Northern New York

    Directory of Open Access Journals (Sweden)

    Michael O’Connor

    2010-05-01

    Full Text Available Samples from private wells (n = 169 throughout St. Lawrence County, NY were analyzed by ICP-MS multi-element techniques. St. Lawrence County spans three diverse bedrock terranes including Precambrian crystalline rocks of the Adirondack Lowlands (mostly paragneisses and Highlands (mostly orthogneisses, as well as Paleozoic sedimentary rocks of the St. Lawrence Valley. An ArcGIS database was constructed and used to generate contour plots for elements across the county. Strontium isotopes and unique geochemical signatures were used to distinguish water from various geologic units. The results were consistent with a large (7,309 km2, sparsely populated (~110,000, rural region with diverse bedrock and glacial cover.

  20. Multi-element bioimaging of Arabidopsis thaliana roots

    DEFF Research Database (Denmark)

    Persson, Daniel Olof; Chen, Anle; Aarts, Mark G.M.

    2016-01-01

    Better understanding of root function is central for the development of plants with more efficient nutrient uptake and translocation. We here present a method for multielement bioimaging at the cellular level in roots of the genetic model system Arabidopsis (Arabidopsis thaliana). Using conventio......Better understanding of root function is central for the development of plants with more efficient nutrient uptake and translocation. We here present a method for multielement bioimaging at the cellular level in roots of the genetic model system Arabidopsis (Arabidopsis thaliana). Using...... omics techniques. To demonstrate the potential of the method, we analyzed a mutant of Arabidopsis unable to synthesize the metal chelator nicotianamine. The mutant accumulated substantially more zinc and manganese than the wild type in the tissues surrounding the vascular cylinder. For iron, the images...... looked completely different, with iron bound mainly in the epidermis of the wild-type plants but confined to the cortical cell walls of the mutant. The method offers the power of inductively coupled plasma-mass spectrometry to be fully employed, thereby providing a basis for detailed studies of ion...

  1. A comparative investigation on structure and multiferroic properties of bismuth ferrite thin films by multielement co-doping

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Guohua; Tan, Guoqiang, E-mail: tan3114@163.com; Luo, Yangyang; Liu, Wenlong; Xia, Ao; Ren, Huijun

    2014-12-15

    Highlights: • Multielement (Tb, Cr and Mn) co-doped BiFeO{sub 3} films were fabricated by CSD method. • Multielement co-doping induces a structural transition. • It is found effective to stabilize the valence of Fe ions at +3 by the strategy. • The co-doping at A/B-sites gives rise to the superior multiferroic properties. - Abstract: (Tb, Cr and Mn) multielement co-doped BiFeO{sub 3} (BTFCMO) thin films were prepared by the chemical solution deposition method on fluorine doped tin oxide (FTO) substrates. X-ray diffraction, Rietveld refinement and Raman analyses revealed that a phase transition from rhombohedral to triclinic structure occurs in the multielement co-doped BiFeO{sub 3} films. It is found that the doping is conducive to stabilizing the valence of Fe ions and reducing leakage current. In addition, the highly enhanced ferroelectric properties with a huge remanent polarization (2P{sub r}) of 239.6 μC/cm{sup 2} and a low coercive field (2E{sub c}) of 615.6 kV/cm are ascribed to the well film texture, the structure transition and the reduced leakage current by the co-doping. Moreover, the structure transition is the dominant factor resulting in the significant enhancement observed in magnetization (M{sub s} ∼ 10.5 emu/cm{sup 3}), owing to the collapse of the space-modulated spin structure. In this contribution, these results demonstrate that the multielement co-doping is in favor of the enhanced multiferroic properties of the BFO films for possible multifunctional applications.

  2. Element availability of bivalve with symbiotic zooxanthellae in coral sea area as studied by multielement profiling analysis

    Science.gov (United States)

    Itoh, A.; Kabe, N.

    2008-12-01

    In coral sea, a characteristic ecosystem is formed by many kinds of marine animals and plants, although seawater is uneutrophic. This may be explained by the fact that various chemical species with bioessentiality are effectively taken and used by lower animals and plants in coral sea area. A symbiotic relationship often found among different animals and plants in this area is considered to be working as one of such processes. However, the specific bioavailability of the elements for the marine animals and plants in coral reef area has not been studied from the viewpoints of trace and ultratrace elements. It is found by the present authors that bivalve with symbiotic zooxanthellae (Tridacna crocea) living on coral reef had relatively higher bio- accumulation factors for many bio-essential elements than other kinds of bivalves, although they live in the uneutrophic sea area. The present authors focused on Tridacna crocea as one of the symbiotic animals. Thus, in the present study, at first, multielement determination of major-to-ultratrace elements (about 20 elements) in each organ of Tridacna crocea with symbiotic zooxanthellae, were carried out by ICP-AES, ICP- MS, and CHN coder. At Second, the specific bioavailability of trace and ultratrace elements in Tridacna crocea was discussed on the multielement data for seawater, seaweeds, and other bivalves in coral sea area.

  3. Pump radiation distribution in multi-element first cladding laser fibres

    International Nuclear Information System (INIS)

    Mel'kumov, Mikhail A; Bufetov, Igor' A; Bubnov, M M; Shubin, Aleksei V; Semenov, S L; Dianov, Evgenii M

    2005-01-01

    Pump radiation transfer is studied experimentally in multi-element first cladding laser fibres. A model of this process is proposed, which is in good agreement with experimental results. An all-fibre single-mode cw ytterbium laser based on a three-element first cladding fibre with an output power of 100W is fabricated. (lasers)

  4. Application of k0-based NAA for multielement determination in serpentines and associated minerals

    International Nuclear Information System (INIS)

    Nagendra Kumar, P.V.; S.V. University, Tirupati; Suresh Kumar, N.; King Fahad Specialist Hospital, Dammam; Acharya, R.; Krishna Reddy, L.; Reddy, A.V.R.

    2014-01-01

    The k 0 -based neutron activation analysis method was applied for multielement determination in black and yellow serpentines along with two associated minerals namely altered and unaltered dolomites and intrusive rock dolerite, obtained from the asbestos mines of Cuddapah basin, Andhra Pradesh, India. Concentrations of 20 elements were determined and they were used to predict the process of formation of fibrous chrysotile asbestos. Majority of elements as well as REEs reveal the contribution of elements from both dolerite and dolomite during the process of contact metamorphism in forming the mineral serpentine. (author)

  5. A computer programme for use in the development of multi-element x-ray-fluorescence methods of analysis

    International Nuclear Information System (INIS)

    Wall, G.J.

    1985-01-01

    A computer programme (written in BASIC) is described for the evaluation of spectral-line intensities in X-ray-fluorescence spectrometry. The programme is designed to assist the analyst while he is developing new analytical methods, because it facilitates the selection of the following evaluation parameters: calculation models, spectral-line correction factors, calibration curves, calibration ranges, and point deletions. In addition, the programme enables the analyst to undertake routine calculations of data from multi-element analyses in which variable data-reduction parameters are used for each element

  6. Studies of the source complex behaviour and of the ultrasound radiation of contact flexible multi-element transducers; Etudes du comportement complexe de source et du rayonnement ultrasonore des traducteurs multi-elements flexibles au contact

    Energy Technology Data Exchange (ETDEWEB)

    Amory, V

    2007-12-15

    This work deals with the ultrasonic nondestructive testing of parts with complex geometries using soft multi-element sensors. The different types of contact control configurations are presented first. Then, the difficulties encountered with conventional contact transducers are explained and the multi-element piezoelectric transducers technology, developed to meet these difficulties, is presented. The second chapter presents the results of finite-element calculations showing the complexity of a transducer in a condition of testing utilization. In a same configuration, the radiated far field calculated by finite-elements is compared to the measurement in order to validate the way the source behaviour is calculated. However, despite the efficiency of the finite-elements simulation, this tool is numerically too costly and cannot be used to optimize a full multi-element transducer. Therefore, a realistic source model is built and implemented in a radiation code based on high-frequency asymptotic approximations where only L and T volume waves are calculated. The incapacity of this model to reproduce the behaviour of T waves in some directions of propagation has led to give a particular attention to the fore-waves, neglected in the radiation calculation. Chapter 3 treats of the building of an exact radiation model taking into consideration the fore-waves contribution emitted by a contact transducer exerting a random space-time distribution constraint at the surface of the considered medium. A radiation model, based on the calculation of exact Green functions of the Lamb problem is proposed. The exact model is particularly interesting in the case of sensor geometries with a long length with respect to other dimensions (2D case). Field calculation results are shown for an element of the matrix network (3D case) and for a linear element (2D case). A study of different existing approached models is carried out as well. The last chapter presents some results of the field

  7. Determination of the power of multielement aerosol composition emission from distant industrial sources

    International Nuclear Information System (INIS)

    Popova, S.A.; Kutsenogij, K.P.; Chankina, O.V.

    2008-01-01

    The results from the monitoring of the temporal variability of the multielement composition of atmospheric aerosols are presented. They are used to determine the emission power of a series of elements from distant sources.

  8. Use of CRM's as mutual calibrating materials and control of synthetic multielement standards as used in INAA

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1987-01-01

    Dilution effects of different multielement synthetic standard solutions were studied by measuring 10-12 different concentrations of the same solution. Peak area comparison of four Certified Reference Materials (CRMs) using one value for the evaluation of the other three repetitively led to the intercomparison (degree of compatibility) of the certified values. The idea of the preparation of each laboratory's 'secondary reference standard' by comparison of synthetic multielement standards with as many CRMs as practically feasible is advocated to improve the reliability of analytical results. (author)

  9. Multi-element proportional counter for radiation protection measurements

    International Nuclear Information System (INIS)

    Kliauga, P.; Rossi, H.H.; Johnson, G.

    1988-01-01

    This article discusses design modifications of a multi-element proportional counter. The original counter exhibited poor resolution, as measured by the width of the event-size spectrum for low-energy photons. It was also suspected that the field inside each volume was not sufficiently symmetric. Results of the modifications showed that a dramatic improvement in resolution could be obtained in the chamber with tissue-equivalent septa if their potentials were adjusted to obtain optimal resolution. The full width at half maximum then approached, although it did not equal, that of a standard spherical counter

  10. Multielement analysis of environmental samples by total-reflection X-ray fluorescence sprectrometry, neutron activation analysis and inductively coupled plasma optical emission spectroscopy

    International Nuclear Information System (INIS)

    Michaelis, W.

    1986-01-01

    In environmental research and protection trace elements have to be determined over a wide range of atomic number, down to very low concentrations, and in quite different matrices. This challenge requires the availability of complementary analytical methods characterized by a high detection power and few sources of systematic errors. Besides, the capacity of multielement detection is often desired since it facilitates the talking of many problems in which numerous trace elements are of direct concern. Total-reflection X-ray fluorescence, neutron activation analysis and inductively coupled plasma optical emission spectroscopy, in principle fulfill these requirements quite well. However, each method has its domain, and the application to certain sample species may be less promising. Under this aspect, the paper summarizes some recent developments and investigations, including intercomparisons as far as possible. Various matrices are considered : rainwater and airborne particulates, soil samples, river sediments and suspended particulate matter, river water filtrates, ozean water, and organic matrices. Capabilities and limitations are discussed. Sample preparation techniques are described if they are new or essential for achieving the results given. (orig.) [de

  11. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  12. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  13. Multielement geochemistry identifies the spatial pattern of soil and sediment contamination in an urban parkland, Western Australia.

    Science.gov (United States)

    Rate, Andrew W

    2018-06-15

    Urban environments are dynamic and highly heterogeneous, and multiple additions of potential contaminants are likely on timescales which are short relative to natural processes. The likely sources and location of soil or sediment contamination in urban environment should therefore be detectable using multielement geochemical composition combined with rigorously applied multivariate statistical techniques. Soil, wetland sediment, and street dust was sampled along intersecting transects in Robertson Park in metropolitan Perth, Western Australia. Samples were analysed for near-total concentrations of multiple elements (including Cd, Ce, Co, Cr, Cu, Fe, Gd, La, Mn, Nd, Ni, Pb, Y, and Zn), as well as pH, and electrical conductivity. Samples at some locations within Robertson Park had high concentrations of potentially toxic elements (Pb above Health Investigation Limits; As, Ba, Cu, Mn, Ni, Pb, V, and Zn above Ecological Investigation Limits). However, these concentrations carry low risk due to the main land use as recreational open space, the low proportion of samples exceeding guideline values, and a tendency for the highest concentrations to be located within the less accessible wetland basin. The different spatial distributions of different groups of contaminants was consistent with different inputs of contaminants related to changes in land use and technology over the history of the site. Multivariate statistical analyses reinforced the spatial information, with principal component analysis identifying geochemical associations of elements which were also spatially related. A multivariate linear discriminant model was able to discriminate samples into a-priori types, and could predict sample type with 84% accuracy based on multielement composition. The findings suggest substantial advantages of characterising a site using multielement and multivariate analyses, an approach which could benefit investigations of other sites of concern. Copyright © 2018 Elsevier B

  14. Use of CRM's as mutual calibrating materials and control of synthetic multielement standards as used in INAA

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1986-01-01

    The comparability of analytical results from different laboratories requires accurately known concentrations in the applied standards. Dilution effects of different multielement synthetic standard solutions have been studied by measuring 10 - 12 different concentrations of the same solution. Peak area comparison of four Certified Reference Materials (CRM's) using one value for the evaluation of the other three repetitively led to the intercomparison (degree of compatibility) of the certified values. The idea of the preparation of each laboratory's ''secondary reference standard'' by comparison of synthetic multielement standards with as many CRM's as practically feasible is advocated to improve the reliability of analytical results. (author)

  15. Multi-element Analysis of variable sample matrices using collision/reaction cell inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Zahran, N.F.; Helal, A.I.; Amr, M.A.; Amr, M.A.; Al-saad, K.A.

    2008-01-01

    An ICP-MS with an octopole reaction/collision cell is used for the multielement determination of trace elements in water, plants, and soil samples. The use of a reaction or collision gas reduces serious spectral interferences from matrix elements such as Ar Cl or Ar Na. The background equivalent concentration (BEC) is reduced one order of magnitude at helium flow rate of 1 mL/min. Certified reference material namely , NIST Water-1643d, Tomato leaves 1573a, and Montana soil 2711 are used. The trace elements Mn, Fe, Co, Ni, Cu, Zn, As, Mo, Cd and Pb are determined in the different matrices with a accuracy better than 8% to the certified values

  16. An Assessment of the Icing Blade and the SEA Multi-Element Sensor for Liquid Water Content Calibration of the NASA GRC Icing Research Tunnel

    Science.gov (United States)

    Steen, Laura E.; Ide, Robert F.; Van Zante, Judith Foss

    2017-01-01

    The Icing Research Tunnel at NASA Glenn has recently switched to from using the Icing Blade to using the SEA Multi-Element Sensor (also known as the multi-wire) for its calibration of cloud liquid water content. In order to perform this transition, tests were completed to compare the Multi-Element Sensor to the Icing Blade, particularly with respect to liquid water content, airspeed, and drop size. The two instruments were found to compare well for the majority of Appendix C conditions. However, it was discovered that the Icing Blade under-measures when the conditions approach the Ludlam Limit. This paper also describes data processing procedures for the Multi-Element Sensor in the IRT, including collection efficiency corrections, mounting underneath a splitter plate, and correcting for a jump in the compensation wire power. Further data is presented to describe the repeatability of the IRT with the Multi-Element sensor, health-monitoring checks for the instrument, and a sensing-element configuration comparison.

  17. Studies of the source complex behaviour and of the ultrasound radiation of contact flexible multi-element transducers

    International Nuclear Information System (INIS)

    Amory, V.

    2007-12-01

    This work deals with the ultrasonic nondestructive testing of parts with complex geometries using soft multi-element sensors. The different types of contact control configurations are presented first. Then, the difficulties encountered with conventional contact transducers are explained and the multi-element piezoelectric transducers technology, developed to meet these difficulties, is presented. The second chapter presents the results of finite-element calculations showing the complexity of a transducer in a condition of testing utilization. In a same configuration, the radiated far field calculated by finite-elements is compared to the measurement in order to validate the way the source behaviour is calculated. However, despite the efficiency of the finite-elements simulation, this tool is numerically too costly and cannot be used to optimize a full multi-element transducer. Therefore, a realistic source model is built and implemented in a radiation code based on high-frequency asymptotic approximations where only L and T volume waves are calculated. The incapacity of this model to reproduce the behaviour of T waves in some directions of propagation has led to give a particular attention to the fore-waves, neglected in the radiation calculation. Chapter 3 treats of the building of an exact radiation model taking into consideration the fore-waves contribution emitted by a contact transducer exerting a random space-time distribution constraint at the surface of the considered medium. A radiation model, based on the calculation of exact Green functions of the Lamb problem is proposed. The exact model is particularly interesting in the case of sensor geometries with a long length with respect to other dimensions (2D case). Field calculation results are shown for an element of the matrix network (3D case) and for a linear element (2D case). A study of different existing approached models is carried out as well. The last chapter presents some results of the field

  18. An Assessment of the SEA Multi-Element Sensor for Liquid Water Content Calibration of the NASA GRC Icing Research Tunnel

    Science.gov (United States)

    Steen, Laura E.; Ide, Robert F.; Van Zante, Judith F.

    2015-01-01

    The NASA Glenn Icing Research tunnel has been using an Icing Blade technique to measure cloud liquid water content (LWC) since 1980. The IRT conducted tests with SEA Multi-Element sensors from 2009 to 2011 to assess their performance in measuring LWC. These tests revealed that the Multi-Element sensors showed some significant advantages over the Icing Blade, particularly at higher water contents, higher impingement rates, and large drop sizes. Results of these and other tests are presented here.

  19. Design and Wind Tunnel Testing of a Thick, Multi-Element High-Lift Airfoil

    DEFF Research Database (Denmark)

    Zahle, Frederik; Gaunaa, Mac; Sørensen, Niels N.

    2012-01-01

    In this work a 2D CFD solver has been used to optimize the shape of a leading edge slat with a chord length of 30% of the main airfoil which was 40% thick. The airfoil configuration was subsequently tested in a wind tunnel and compared to numerical predictions. The multi-element airfoil was predi...

  20. The multi-element probabilistic collocation method (ME-PCM): Error analysis and applications

    International Nuclear Information System (INIS)

    Foo, Jasmine; Wan Xiaoliang; Karniadakis, George Em

    2008-01-01

    Stochastic spectral methods are numerical techniques for approximating solutions to partial differential equations with random parameters. In this work, we present and examine the multi-element probabilistic collocation method (ME-PCM), which is a generalized form of the probabilistic collocation method. In the ME-PCM, the parametric space is discretized and a collocation/cubature grid is prescribed on each element. Both full and sparse tensor product grids based on Gauss and Clenshaw-Curtis quadrature rules are considered. We prove analytically and observe in numerical tests that as the parameter space mesh is refined, the convergence rate of the solution depends on the quadrature rule of each element only through its degree of exactness. In addition, the L 2 error of the tensor product interpolant is examined and an adaptivity algorithm is provided. Numerical examples demonstrating adaptive ME-PCM are shown, including low-regularity problems and long-time integration. We test the ME-PCM on two-dimensional Navier-Stokes examples and a stochastic diffusion problem with various random input distributions and up to 50 dimensions. While the convergence rate of ME-PCM deteriorates in 50 dimensions, the error in the mean and variance is two orders of magnitude lower than the error obtained with the Monte Carlo method using only a small number of samples (e.g., 100). The computational cost of ME-PCM is found to be favorable when compared to the cost of other methods including stochastic Galerkin, Monte Carlo and quasi-random sequence methods

  1. Overview of multi-element monolithic germanium detectors for XAFS experiments at diamond light source

    International Nuclear Information System (INIS)

    Chatterji, S.; Dennis, G. J.; Dent, A.; Diaz-Moreno, S.; Cibin, G.; Tartoni, N.; Helsby, W. I.

    2016-01-01

    An overview of multi-element monolithic germanium detectors being used at the X-ray absorption spectroscopy (XAS) beam lines at Diamond Light Source (DLS) is being reported. The hardware details and a summary of the performance of these detectors have also been provided. Recent updates about various ongoing projects being worked on to improve the performance of these detectors are summarized.

  2. Overview of multi-element monolithic germanium detectors for XAFS experiments at diamond light source

    Energy Technology Data Exchange (ETDEWEB)

    Chatterji, S.; Dennis, G. J.; Dent, A.; Diaz-Moreno, S.; Cibin, G.; Tartoni, N. [Diamond Light Source Ltd, Oxfordshire (United Kingdom); Helsby, W. I. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2016-07-27

    An overview of multi-element monolithic germanium detectors being used at the X-ray absorption spectroscopy (XAS) beam lines at Diamond Light Source (DLS) is being reported. The hardware details and a summary of the performance of these detectors have also been provided. Recent updates about various ongoing projects being worked on to improve the performance of these detectors are summarized.

  3. Application of inductively coupled plasma mass spectrometry for multielement analysis in small sample amounts of thyroid tissue from Chernobyl area

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietze, H.J.; Boulyga, S.F.; Bazhanova, N.N.; Kanash, N.V.; Malenchenko, A.F.

    2000-01-01

    As a result of the Chernobyl nuclear power plant accident in 1986, thyroid pathologies occurred among children in some regions of belarus. Besides the irradiation of children's thyroids by radioactive iodine and caesium nuclides, toxic elements from fallout are a direct risk to health. Inductively coupled plasma quadrupole-based mass spectrometry (Icp-Ms) and instrumental neutron activation analysis (IAA) were used for multielement determination in small amounts (I-10 mg) of human thyroid tissue samples. The accuracy of the applied analytical technique for small biological sample amounts was checked using NIST standard reference material oyster tissue (SRM 1566 b). Almost all essential elements as well as a number of toxic elements such as Cd, Pb, Hg, U etc. Were determined in a multitude of human thyroid tissues by quadrupole-based Icp-Ms using micro nebulization. In general, the thyroid tissue affected by pathology is characterized by higher calcium content. Some other elements, among them Sr, Zn, Fe, Mn, V, As, Cr, Ni, Pb, U, Ba, Sb, were also Accumulated in such tissue. The results obtained will be used as initial material for further specific studies of the role of particular elements in thyroid pathology development

  4. Multi-element isotope dilution analyses using ICP-MS

    International Nuclear Information System (INIS)

    Volpe, A.M.

    1996-01-01

    Presently, 37 elements ranging from light (Li,B) through transition metals, noble, rare earth and heavy elements, to actinides and transuranics (Pu, Am, Cm) are measured by isotope dilution at Lawrence Livermore National Laboratory. Projects range from geological and hydrological to biological. The research goal is to measure accurately many elements present in diverse matrices at trace (ppb) levels using isotope dilution methods. Major advantages of isotope dilution methods are accuracy, elimination of ion intensity calibration, and quantitation for samples that require chemical separation. Accuracy depends on tracer isotope calibration, tracer-sample isotopic equilibration, and appropriate background, isobaric and mass bias corrections. Propagation of isotope ratio error due to improper tracer isotope addition is a major concern with multi-element analyses when abundances vary widely. 11 refs., 3 figs

  5. Application of PCA-LDA method to determine the geographical origin of tea based on determination of stable isotopes and multi-elements

    International Nuclear Information System (INIS)

    Yuan Yuwei; Zhang Yongzhi; Yang Guiling; Zhang Zhiheng; Fu Haiyan; Han Wenyan; Li Shufang

    2013-01-01

    The ratio of stable isotope and concentration of multi-element in tea was determinated with isotope ratio mass spectrometry (IRMS) and inductively coupled plasma mass spectrometry (ICP-MS). Pattern recognition techniques with principal component analysis (PCA) and linear discriminant analysis (LDA) were used to classify the geographical origins of tea from Fujian, Shandong and Zhejiang province, and Yuyao, Jinhua and Xihu region of Zhejiang. The results showed the values of δ"1"5N, δ"1"3C, δD, δ"1"8O and the ratios of "2"0"6Pb/"2"0"7Pb, "2"0"8Pb/"2"0"6Pb and "8"7Sr/"8"6Sr in tea samples were different from different origins. There was also large variable for the concentrations of 27 mineral elements, such as Li, Be, Na and so on, with a specific character of origin. The method of PCA could be used to classify the geographical origin of tea from different origins but with a cross in the scatter plot. However, PCA combining with LDA could gave correct assignation percentages of 99% for the tea samples among Fujian, Shandong and Zhejiang provinces, and 87% for the tea samples among Yuyao, Jinhua and Xihu region of Zhejiang. These results revealed that it was possible and feasible to classify the geographical origin of tea by the method of PCA-LDA based on the determination of isotopes and multi-elements. (authors)

  6. Theory and Experiment of Multielement Airfoils: A Comparison

    Science.gov (United States)

    Czerwiec, Ryan; Edwards, J. R.; Rumsey, C. L.; Hassan, H. A.

    2000-01-01

    A detailed comparison of computed and measured pressure distributions, velocity profiles, transition onset, and Reynolds shear stresses for multi-element airfoils is presented. It is shown that the transitional k-zeta model, which is implemented into CFL3D, does a good job of predicting pressure distributions, transition onset, and velocity profiles with the exception of velocities in the slat wake region. Considering the fact that the hot wire used was not fine enough to resolve Reynolds stresses in the boundary layer, comparisons of turbulence stresses varied from good to fair. It is suggested that the effects of unsteadiness be thoroughly evaluated before more complicated transition/turbulence models are used. Further, it is concluded that the present work presents a viable and economical method for calculating laminar/transitional/turbuient flows over complex shapes without user interface.

  7. Dynamic response of a multielement HTGR core

    International Nuclear Information System (INIS)

    Reich, M.; Bezler, P.; Koplik, B.; Curreri, J.; Goradia, H.; Lasker, L.

    1977-01-01

    One of the primary factors in determining the structural integrity and consequently the safety of a High Temperature Gas-Cooled Reactor (HTGR) is the dynamic response of the core when subjected to a seismic excitation. The HTGR core under consideration consists of several thousands of hexagonal elements arranged in vertical stacks containing about eight elements per stack. There are clearance gaps between adjacent elements, which can change substantially due to radiation effects produced during their active lifetime. Surrounding the outer periphery of the core are reflector blocks and restraining spring-pack arrangements which bear against the reactor vessel structure (PCRV). Earthquake input motions to this type of core arrangement will result in multiple impacts between adjacent elements as well as between the reflector blocks and the restraining spring packs. The highly complex nonlinear response associated with the multiple collisions across the clearance gaps and with the spring packs is the subject matter of this paper. Of particular importance is the ability to analyze a complex nonlinear system with gaps by employing a model with a reduced number of masses. This is necessary in order to obtain solutions in a time-frame and at a cost which is not too expensive. In addition the effect of variations in total clearance as well as the initial distribution of clearances between adjacent elements is of primary concern. Both of these aspects of the problem are treated in the present analysis. Finally, by constraining the motion of the reflector blocks, a more realistic description of the dynamic response of the multi-element HTGR core is obtained

  8. A multi-element cosmological model with a complex space-time topology

    Science.gov (United States)

    Kardashev, N. S.; Lipatova, L. N.; Novikov, I. D.; Shatskiy, A. A.

    2015-02-01

    Wormhole models with a complex topology having one entrance and two exits into the same space-time of another universe are considered, as well as models with two entrances from the same space-time and one exit to another universe. These models are used to build a model of a multi-sheeted universe (a multi-element model of the "Multiverse") with a complex topology. Spherical symmetry is assumed in all the models. A Reissner-Norström black-hole model having no singularity beyond the horizon is constructed. The strength of the central singularity of the black hole is analyzed.

  9. Multielement X-ray row detector on GaAs with spatial resolution of 108 μm

    International Nuclear Information System (INIS)

    Dvoryankin, V.F.; Dikaev, Yu.M.; Krikunov, A.I.; Panova, T.M.; Telegin, A.A.

    2004-01-01

    The multielement X-ray row detector with pitch of 108 μm was made on epitaxial GaAs (p + -n-n'-n + ) structures by isotropic etching in solution HCl-KBrO 3 -H 2 O. Separation of signals from the near-by detectors is achieved by built-in guard ring on each pixel. The spatial response of the detectors was evaluated

  10. NanoSIMS multi-element imaging reveals internalisation and nucleolar targeting for a highly-charged polynuclear platinum compound.

    Science.gov (United States)

    Wedlock, Louise E; Kilburn, Matt R; Liu, Rong; Shaw, Jeremy A; Berners-Price, Susan J; Farrell, Nicholas P

    2013-08-11

    Simultaneous multi-element imaging using NanoSIMS (nano-scale secondary ion mass spectrometry), exploiting the novel combination of (195)Pt and (15)N in platinum-am(m)ine antitumour drugs, provides information on the internalisation and subcellular localisation of both metal and ligands, and allows identification of ligand exchange.

  11. Chemical elements in the environment: multi-element geochemical datasets from continental to national scale surveys on four continents

    Science.gov (United States)

    Caritat, Patrice de; Reimann, Clemens; Smith, David; Wang, Xueqiu

    2017-01-01

    During the last 10-20 years, Geological Surveys around the world have undertaken a major effort towards delivering fully harmonized and tightly quality-controlled low-density multi-element soil geochemical maps and datasets of vast regions including up to whole continents. Concentrations of between 45 and 60 elements commonly have been determined in a variety of different regolith types (e.g., sediment, soil). The multi-element datasets are published as complete geochemical atlases and made available to the general public. Several other geochemical datasets covering smaller areas but generally at a higher spatial density are also available. These datasets may, however, not be found by superficial internet-based searches because the elements are not mentioned individually either in the title or in the keyword lists of the original references. This publication attempts to increase the visibility and discoverability of these fundamental background datasets covering large areas up to whole continents.

  12. Determination of the geographic origin of rice by chemometrics with strontium and lead isotope ratios and multielement concentrations.

    Science.gov (United States)

    Ariyama, Kaoru; Shinozaki, Miyuki; Kawasaki, Akira

    2012-02-22

    The objective of this study was to develop a technique for determining the country of origin of rice in the Japanese market. The rice samples included a total of 350 products grown in Japan (n = 200), the United States (n = 50), China (n = 50), and Thailand (n = 50). In this study, (87)Sr/(86)Sr and Pb isotope ((204)Pb, (206)Pb, (207)Pb, and (208)Pb) ratios and multielement concentrations (Al, Fe, Co, Ni, Cu, Rb, Sr, and Ba) were determined by high-resolution inductively coupled plasma mass spectrometry. By combining three chemometric techniques based on different principles and determination criteria, the countries of origin of rice were determined. The predictions made by 10-fold cross-validation were around 97% accurate. The presented method demonstrated the effectiveness of determining the geographic origin of an agricultural product by combining several chemometric techniques using heavy element isotope ratios and multielement concentrations.

  13. Multi-element analysis of the rat hippocampus by proton induced x-ray emission spectroscopy (phosphorus, sulfur, chlorine, potassium, calcium, iron, zinc, copper, lead, bromine, and rubidium)

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Danscher, G.

    1979-01-22

    A technique for multi-element analysis of brain tissue by proton induced x-ray emission spectroscopy (PIXE) is described and data from analysis of fixed and unfixed samples from rat hippocampus, neocortex, amygdala, and spinal cord are presented and commented on. The atoms present in the tissue are bombarded with protons which cause the ejection of electrons from the inner shells. When the holes are refilled with electrons from outer shells, x-ray quanta characteristic for each element are emitted. Using a high resolution energy dispersive detector, a complete x-ray spectrum of the specimen can be recorded in a single measurement. Detection limits less than or approximately 5 ppM of dry matter are obtained for most elements with atomic number greater than 14 (silicon). Around 13 elements were found in concentrations above the detection limits. The grand means for non-fixed hippocampi were e.g., for Zn-120 ppM; Rb-20 ppM; Fe-150 ppM; Pb-3 ppM; Ni-5 ppM.

  14. Multielement X-ray row detector on GaAs with spatial resolution of 108 {mu}m

    Energy Technology Data Exchange (ETDEWEB)

    Dvoryankin, V.F.; Dikaev, Yu.M. E-mail: ymd289@ire216.msk.ru; Krikunov, A.I.; Panova, T.M.; Telegin, A.A

    2004-09-21

    The multielement X-ray row detector with pitch of 108 {mu}m was made on epitaxial GaAs (p{sup +}-n-n'-n{sup +}) structures by isotropic etching in solution HCl-KBrO{sub 3}-H{sub 2}O. Separation of signals from the near-by detectors is achieved by built-in guard ring on each pixel. The spatial response of the detectors was evaluated.

  15. Multielement geochemical reconnaissance for uranium in the Palmyrides region of central Syria

    International Nuclear Information System (INIS)

    Jubeli, Y.M.; Hale, M.

    1988-01-01

    Multielement reconnaissance geochemistry coupled with ground scintillation gamma ray measurements has been used to investigate the dispersion patterns of uranium and other major and trace elements in the arid Palmyrides region of central Syria. Over 500 geochemical samples of outcropping rock, wadi and playa sediments, overburden and groundwaters were taken over an area of approximately 9000 sq km. Most samples were analyzed for 25 major and trace elements by nebulization ICPAES; for As, Sb, Bi and Se by hydride generation and ICPAES; and for U, Th and La and other REE by neutron activation analysis. The resulting data were interpreted with the aid of univariate and multivariate statistical methods. The areal distributions of U, its associated elements, multivariate geochemical functions and factor scores were mapped using computer graphics. Results of the factor analysis indicate that the primary lithogeochemical dispersion patterns of uranium and associated elements are controlled by a combination of structural, lithological and environmental factors. Uranium and associated elements have subsequently been leached out of the phosphorite and other U enriched clayey limestones and carbonate rocks into the hydro- geologic regime. Redistribution of these elements is taking place along fracture zones and major faults. A degree of urnaium accumulation in a Neogene aquifer of the Ad-Daww basin is evident

  16. Multielement determination of trace elements in seawater by inductively coupled plasma mass spectrometry after tandem preconcentration with cooperation of chelating resin adsorption and lanthanum coprecipitation

    International Nuclear Information System (INIS)

    Yabutani, Tomoki; Chiba, Koichi; Haraguchi, Hiroki

    2001-01-01

    A tandem preconcentration method, in which chelating resin adsorption and La coprecipitation were cooperatively employed for preconcentration, was developed as a pretreatment method for simultaneous multielement determination of trace elements in seawater by ICP-MS. First, the seawater sample (250 ml) was treated with a chelating resin for preconcentration of trace elements, and then trace elements with good recoveries were determined by ICP-MS. Trace elements with the chemical properties of oxoanion- and hydride-formation, which were poorly recovered in the chelating resin preconcentration, were further subjected to preconcentration by La coprecipitation. As a result, more than 30 elements could be determined in the concentration range from 9.6 μg L -1 for Mo to 0.00018 μg L -1 for Tm, when the present tandem method was applied to the analysis of open seawater standard reference material (NASS-4). Furthermore, the analytical results for open seawater reference materials were compared with those for coastal seawater reference material as well as for coastal seawater collected in the Ise Bay. It was found that the multielement data for trace elements in these seawater samples clearly showed different elemental distributions, reflecting the different marine environments. (author)

  17. The multi-element ultrasonic technology: examples of application on military naval structures

    International Nuclear Information System (INIS)

    Recolin, P.; Rivalin, S.

    2009-01-01

    DCNS is the European leader in the military ship construction and maintenance (conventional and nuclear propulsion). The potential of ultrasonic technologies with multi-element probes has been studied in its Materials laboratory since the end of the 80's, and a growing number of applications has appeared these last ten years. A series of examples is given: in-service nuclear reactor pipe welds monitoring, time-of-flight diffraction (TOFD) technique for the inspection of containment welds, coating fabrication control, detection of laminating corrosion on aluminum rings, detection of corrosion on submarine hulls in basin, inspection of hull welded joints

  18. Process recognition in multi-element soil and stream-sediment geochemical data

    Science.gov (United States)

    Grunsky, E.C.; Drew, L.J.; Sutphin, D.M.

    2009-01-01

    Stream-sediment and soil geochemical data from the Upper and Lower Coastal Plains of South Carolina (USA) were studied to determine relationships between soils and stream sediments. From multi-element associations, characteristic compositions were determined for both media. Primary associations of elements reflect mineralogy, including heavy minerals, carbonates and clays, and the effects of groundwater. The effects of groundwater on element concentrations are more evident in soils than stream sediments. A "winnowing index" was created using ratios of Th to Al that revealed differing erosional and depositional environments. Both soils and stream sediments from the Upper and Lower Coastal Plains show derivation from similar materials and subsequent similar multi-element relationships, but have some distinct differences. In the Lower Coastal Plain, soils have high values of elements concentrated in heavy minerals (Ce, Y, Th) that grade into high values of elements concentrated into finer-grain-size, lower-density materials, primarily comprised of carbonates and feldspar minerals (Mg, Ca, Na, K, Al). These gradational trends in mineralogy and geochemistry are inferred to reflect reworking of materials during marine transgressions and regressions. Upper Coastal Plain stream-sediment geochemistry shows a higher winnowing index relative to soil geochemistry. A comparison of the 4 media (Upper Coastal Plain soils and stream sediments and Lower Coastal Plain soils and stream sediments) shows that Upper Coastal Plain stream sediments have a higher winnowing index and a higher concentration of elements contained within heavy minerals, whereas Lower Coastal Plain stream sediments show a strong correlation between elements typically contained within clays. It is not possible to calculate a functional relationship between stream sediment-soil compositions for all elements due to the complex history of weathering, deposition, reworking and re-deposition. However, depending on

  19. Automation system for measurement of gamma-ray spectra of induced activity for multi-element high-volume neutron activation analysis at the IBR-2 reactor of FLNP at JINR

    International Nuclear Information System (INIS)

    Pavlov, S.S.; Dmitriev, A.Yu.; Chepurchenko, I.A.; Frontas'eva, M.V.

    2014-01-01

    The automation system for measurement of induced activity of gamma-ray spectra for multi-element high-volume neutron activation analysis (NAA) was designed, developed and implemented at the IBR-2 reactor. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis linear positioning module M202A by DriveSet (DriveSet.de) company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec (systec.de) company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database. The system is unique and can be recommended for other laboratories as one of the possible ways of the NAA integrated automation

  20. The evaluation of multi-element personal dosemeters using the linear programming method

    International Nuclear Information System (INIS)

    Kragh, P.; Ambrosi, P.; Boehm, J.; Hilgers, G.

    1996-01-01

    Multi-element dosemeters are frequently used in individual monitoring. Each element can be regarded as an individual dosemeter with its own individual dose measurement value. In general, the individual dose values of one dosemeter vary according to the exposure conditions, i. e. the energy and angle of incidence of the radiation. The (final) dose measurement value of the personal dosemeter is calculated from the individual dose values by means of an evaluation algorithm. The best possible dose value, i.e. that of the smallest systematic (type B) uncertainty if the exposure conditions are changed in the dosemeter's rated range of use, is obtained by the method of linear programming. (author)

  1. Multielement atmospheric deposition study in Croatia using moss biomonitoring, NAA, AAS and GIS technologies

    International Nuclear Information System (INIS)

    Spiric, Z.; Frontas'eva, M.V.; Gundorina, S.F.; Ostrovnaya, T.M.; Stafilov, T.; Enimiteva, V.; Steinnes, E.; Bukovec, D.

    2009-01-01

    For the first time the moss biomonitoring technique and two complementary analytical techniques - neutron activation analysis (NAA) and atomic absorption spectrometry (AAS) - were applied to study multielement atmospheric deposition in the Republic of Croatia. Moss samples were collected during the summer 2006 from 98 sites evenly distributed over the country. Sampling was performed in accordance with the LRTAP Convention - ICP Vegetation protocol and sampling strategy of the European Programme on Biomonitoring of Heavy Metal Atmospheric Deposition. Conventional and epithermal neutron activation analyses made it possible to determine concentrations of 41 elements including key heavy metals such as Pb, Cd, Hg, and Cu determined by AAS. Principal component analysis (factor analysis with VARIMAX rotation) was applied to distinguish elements mainly of anthropogenic origin from those predominantly originating from natural sources. Geographical distribution maps of the elements over the sampled territory were constructed using GIS technology. The median values for Croatia are consistent with the corresponding values for all Europe for most elements. It was shown that the Adriatic coastline of Croatia may be considered as an environmentally pristine area. This study was conducted for providing reliable assessment of air quality throughout Croatia and producing information needed for better identification of pollution sources and improving the potential for assessing environmental and health risks in Croatia associated with toxic metals

  2. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    International Nuclear Information System (INIS)

    Katskov, Dmitri

    2015-01-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D 2 and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  3. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    Energy Technology Data Exchange (ETDEWEB)

    Katskov, Dmitri, E-mail: katskovda@tut.ac.za

    2015-03-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D{sub 2} and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground

  4. Spectral response of multi-element silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ludewigt, B.A.; Rossington, C.S.; Chapman, K. [Univ. of California, Berkeley, CA (United States)

    1997-04-01

    Multi-element silicon strip detectors, in conjunction with integrated circuit pulse-processing electronics, offer an attractive alternative to conventional lithium-drifted silicon Si(Li) and high purity germanium detectors (HPGe) for high count rate, low noise synchrotron x-ray fluorescence applications. One of the major differences between the segmented Si detectors and the commercially available single-element Si(Li) or HPGe detectors is that hundreds of elements can be fabricated on a single Si substrate using standard silicon processing technologies. The segmentation of the detector substrate into many small elements results in very low noise performance at or near, room temperature, and the count rate of the detector is increased many-fold due to the multiplication in the total number of detectors. Traditionally, a single channel of detector with electronics can handle {approximately}100 kHz count rates while maintaining good energy resolution; the segmented detectors can operate at greater than MHz count rates merely due to the multiplication in the number of channels. One of the most critical aspects in the development of the segmented detectors is characterizing the charge sharing and charge loss that occur between the individual detector strips, and determining how these affect the spectral response of the detectors.

  5. An approach to unfold the response of a multi-element system using an artificial neural network

    International Nuclear Information System (INIS)

    Cordes, E.; Fehrenbacher, G.; Schuetz, R.; Sprunck, M.; Hahn, K.; Hofmann, R.; Wahl, W.

    1998-01-01

    An unfolding procedure is proposed which aims at obtaining spectral information of a neutron radiation field by the analysis of the response of a multi-element system consisting of converter type semiconductors. For the unfolding procedure an artificial neural network (feed forward network), trained by the back-propagation method, was used. The response functions of the single elements to neutron radiation were calculated by application of a computational model for an energy range from 10 -2 eV to 10 MeV. The training of the artificial neural network was based on the computation of responses of a six-element system for a set of 300 neutron spectra and the application of the back-propagation method. The validation was performed by the unfolding of 100 computed responses. Two unfolding examples were pointed out for the determination of the neutron spectra. The spectra resulting from the unfolding procedure agree well with the original spectra used for the response computation

  6. The 1 MV multi-element AMS system for biomedical applications at the Netherlands Organization for Applied Scientific Research (TNO)

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Matthias, E-mail: mklein@highvolteng.com [High Voltage Engineering Europa B.V., P.O. Box 99, 3800 AB Amersfoort (Netherlands); Vaes, W.H.J.; Fabriek, B.; Sandman, H. [TNO, P.O. Box 360, 3700 AJ Zeist (Netherlands); Mous, D.J.W.; Gottdang, A. [High Voltage Engineering Europa B.V., P.O. Box 99, 3800 AB Amersfoort (Netherlands)

    2013-01-15

    The Netherlands Organization for Applied Scientific Research (TNO) has installed a compact 1 MV multi-element AMS system manufactured by High Voltage Engineering Europa B.V., The Netherlands. TNO performs clinical research programs for pharmaceutical and innovative foods industry to obtain early pharmacokinetic data and to provide anti-osteoporotic efficacy data of new treatments. The AMS system will analyze carbon, iodine and calcium samples for this purpose. The first measurements on blank samples indicate background levels in the low 10{sup -12} for calcium and iodine, making the system well suited for these biomedical applications. Carbon blanks have been measured at low 10{sup -16}. For unattended, around-the-clock analysis, the system features the 200 sample version of the SO110 hybrid ion source and user friendly control software.

  7. A new XRF probe for in-situ determining concentration of multi-elements in ocean sediments

    International Nuclear Information System (INIS)

    Ge Liangquan; Lai Wanchang; Zhou Sichun; Lin Ling; Lin Yanchang; Ren Jiafu

    2001-01-01

    The author introduces a new X-ray fluorescence probe for in-situ determining the concentration of multi-elements in ocean sediments. The probe consists of Si-Pin X-ray detector with an electro-thermal colder, two isotope sources, essential electrical signal processing units and a notebook computer. More than 10 elements can be simultaneously determined at a detection limit of (10-200) x 10 -6 and precision of 5%-30% without liquid Nitrogen supply. tests show that the probe can perform the analytical tasks under the water at the depth of less than 1000 meters

  8. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions

    Science.gov (United States)

    Giuliano, Antonella; Astolfi, Maria Luisa; Congedo, Rossana; Masotti, Andrea; Canepari, Silvia

    2018-01-01

    Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents’ efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements’ removal efficiency which resulted to be in correlation with the specific adsorbents’ chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements. PMID:29495363

  9. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions.

    Science.gov (United States)

    Massimi, Lorenzo; Giuliano, Antonella; Astolfi, Maria Luisa; Congedo, Rossana; Masotti, Andrea; Canepari, Silvia

    2018-02-26

    Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents' efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements' removal efficiency which resulted to be in correlation with the specific adsorbents' chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements.

  10. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions

    Directory of Open Access Journals (Sweden)

    Lorenzo Massimi

    2018-02-01

    Full Text Available Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents’ efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements’ removal efficiency which resulted to be in correlation with the specific adsorbents’ chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements.

  11. Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.

    Science.gov (United States)

    Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka

    2010-05-01

    A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.

  12. Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS — A practical application

    Directory of Open Access Journals (Sweden)

    Renata Brodzka

    2013-04-01

    Full Text Available Objectives: The method for the determination of As, Al, Cd, Ni, Pb (toxic elements and Cr, Co, Cu, Fe, Mn, Zn (essential elements in human urine by the use of Inductively Coupled Plasma Mass Spectrometry (quadrupole ICP-MS DRCe Elan, Perkin Elmer with the dynamic reaction cell (DRC was developed. Materials and Methods: The method has been applied for multi-element analysis of the urine of 16 non-exposed healthy volunteers and 27 workers employed in a copper smelter. The analysis was conducted after initial 10-fold dilution of the urine samples with 0,1% nitric acid. Rhodium was used as an internal standard. The method validation parameters such as detection limit, sensitivity, precision were described for all elements. Accuracy of the method was checked by the regular use of certified reference materials ClinCheck®-Control Urine (Recipe as well as by participation of the laboratory in the German External Quality Assessment Scheme (G-EQUAS. Results: The detection limits (DL 3s of the applied method were 0.025, 0.007, 0.002, 0.004, 0.004, 0.086, 0.037, 0.009, 0.016, 0.008, 0.064 (μg/l for Al, As, Cd, Cr, Co, Cu, Fe, Mn, Ni, Pb, Zn in urine, respectively. For each element linearity with correlation coefficient of at least 0.999 was determined. Spectral interferences from some of the ions were removed using DRC-e with addition of alternative gas: methane for cobalt, copper, cadmium, chromium, iron, manganese, nickel and rhodium, and oxygen for arsenic. Conclusions: The developed method allows to determine simultaneously eleven elements in the urine with low detection limits, high sensitivity and good accuracy. Moreover, the method is appropriate for the assessment of both environmental and occupational exposure.

  13. Design considerations regarding an atomizer for multi-element electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Katskov, Dmitri A., E-mail: katskovda@tut.ac.za [Department of Chemistry, Tshwane University of Technology, Private Bag X680, Pretoria 0001 (South Africa); Sadagov, Yuri M. [All-Russian Scientific Research Institute of Optical and Physical Measurements (VNIIOFI), Ozernaya St. 46, Moscow 119361 (Russian Federation)

    2011-06-15

    The methodology of simultaneous multi-element electrothermal atomic absorption spectrometry (ETAAS-Electrothermal Atomic Absorption Spectrometry) stipulates rigid requirements to the design and operation of the atomizer. It must provide high degree of atomization for the group of analytes, invariant respective to the vaporization kinetics and heating ramp residence time of atoms in the absorption volume and absence of memory effects from major sample components. For the low resolution spectrometer with a continuum radiation source the reduced compared to traditional ETAAS (Electrothermal Atomic Absorption Spectrometry) sensitivity should be, at least partially, compensated by creating high density of atomic vapor in the absorption pulse. The sought-for characteristics were obtained for the 18 mm in length and 2.5 mm in internal diameter longitudinally heated graphite tube atomizer furnished with 2-4.5 mg of ring shaped carbon fiber yarn collector. The collector located next to the sampling port provides large substrate area that helps to keep the sample and its residue in the central part of the tube after drying. The collector also provides a 'platform' effect that delays the vaporization and stipulates vapor release into absorption volume having already stabilized gas temperature. Due to the shape of external surface of the tube, presence of collector and rapid (about 10 {sup o}C/ms) heating, an inverse temperature distribution along the tube is attained at the beginnings of the atomization and cleaning steps. The effect is employed for cleaning of the atomizer using the set of short maximum power heating pulses. Preparation, optimal maintenance of the atomizer and its compliance to the multi-element determination requirements are evaluated and discussed. The experimental setup provides direct simultaneous determination of large group of element within 3-4 order concentration range. Limits of detection are close to those for sequential single element

  14. A new XRF probe for in-situ determining concentration of multi-elements in ocean sediments

    CERN Document Server

    Ge Liang Quan; Zhou Si Chun; Lin Ling; Lin Yan Chang; Ren Jia Fu

    2001-01-01

    The author introduces a new X-ray fluorescence probe for in-situ determining the concentration of multi-elements in ocean sediments. The probe consists of Si-Pin X-ray detector with an electro-thermal colder, two isotope sources, essential electrical signal processing units and a notebook computer. More than 10 elements can be simultaneously determined at a detection limit of (10-200) x 10 sup - sup 6 and precision of 5%-30% without liquid Nitrogen supply. tests show that the probe can perform the analytical tasks under the water at the depth of less than 1000 meters

  15. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  16. Proton exciting X ray analysis

    International Nuclear Information System (INIS)

    Ma Xinpei

    1986-04-01

    The analyzing capability of proton exciting X ray analysis for different elements in organisms was discussed, and dealing with examples of trace element analysis in the human body and animal organisms, such as blood serum, urine, and hair. The sensitivity, accuracy, and capability of multielement analysis were discussed. Its strong points for the trace element analysis in biomedicine were explained

  17. Combination of multielement technique (INAA and ICP-MS) for a French air pollution bio-monitoring survey using mosses

    International Nuclear Information System (INIS)

    Ayrault, S.; Deschamps, C.; Amblard, G.; Galsomies, L.; Letrouit-Galinou, M.A.; Bonhomme, P.

    1998-01-01

    This work presents the use of two trace analysis techniques through the data obtained for a significant part of the 557 mosses sampled in France. Sampling were made within the framework of European survey carried out in 1995-1996 and proposed by the Nordic Council. The analyses were produced with a combination of two multielement analysis techniques: INAA (Instrumental Neutron Activation Analysis) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry). Theses two techniques were suitable for trace analyses in mosses. They were clearly complementary and provided for 36 elements including the heavy metals of key interest in air pollution studies. The choice of the technique for a given element depended on the feasibility (e g. Pb is not attainable by INAA), the detection limit, the analytical variability, the preparation procedures and the concentration ranges (5-100 μg/g for Pb, 0.5-5 μg/g for As). INAA measured the total content in the sample, while ICP-MS demanded a mineralization procedure resulting in losses/contamination hazards. Thus, INAA results were preferred, although this technique was time consuming. However the ICP-MS results for Cd, Cu, Ni and Pb were retained, for different reasons: detection limits (Cd, Cu), no convenient INAA conditions (Ni), and feasibility (Pb). (authors)

  18. Application of dot matrix LCD in multi-element portable X-ray fluorescence spectrometry The LCD is stated for Liquid Crystal Display

    CERN Document Server

    Lin Yan Chang; Lai Wan Chang; Zhou Si Chun

    2002-01-01

    Dot matrix LCD based on T6963C is a low power supply module. It needs no complex interface circuits connecting with MCU. Application in text and graphics is easy. Application of this LCD in multi-element portable XRF spectrometry is show. How to use it in Chinese, pull-down menu, spectrum and how to design the interface circuits with embedded computer are shown as well

  19. Navier-Stokes calculations on multi-element airfoils using a chimera-based solver

    Science.gov (United States)

    Jasper, Donald W.; Agrawal, Shreekant; Robinson, Brian A.

    1993-01-01

    A study of Navier-Stokes calculations of flows about multielement airfoils using a chimera grid approach is presented. The chimera approach utilizes structured, overlapped grids which allow great flexibility of grid arrangement and simplifies grid generation. Calculations are made for two-, three-, and four-element airfoils, and modeling of the effect of gap distance between elements is demonstrated for a two element case. Solutions are obtained using the thin-layer form of the Reynolds averaged Navier-Stokes equations with turbulence closure provided by the Baldwin-Lomax algebraic model or the Baldwin-Barth one equation model. The Baldwin-Barth turbulence model is shown to provide better agreement with experimental data and to dramatically improve convergence rates for some cases. Recently developed, improved farfield boundary conditions are incorporated into the solver for greater efficiency. Computed results show good comparison with experimental data which include aerodynamic forces, surface pressures, and boundary layer velocity profiles.

  20. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    Energy Technology Data Exchange (ETDEWEB)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki [Dept. of Applied Chemistry, Graduate School of Engineering, Nagoya Univ. (Japan)

    2000-06-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm{sup -3}) HNO{sub 3} solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  1. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    International Nuclear Information System (INIS)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki

    2000-01-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm -3 ) HNO 3 solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  2. Multi-element, multi-compound isotope profiling as a means to distinguish the geographical and varietal origin of fermented cocoa (Theobroma cacao L.) beans.

    Science.gov (United States)

    Diomande, Didier; Antheaume, Ingrid; Leroux, Maël; Lalande, Julie; Balayssac, Stéphane; Remaud, Gérald S; Tea, Illa

    2015-12-01

    Multi-element stable isotope ratios have been assessed as a means to distinguish between fermented cocoa beans from different geographical and varietal origins. Isotope ratios and percentage composition for C and N were measured in different tissues (cotyledons, shells) and extracts (pure theobromine, defatted cocoa solids, protein, lipids) obtained from fermented cocoa bean samples. Sixty-one samples from 24 different geographical origins covering all four continental areas producing cocoa were analyzed. Treatment of the data with unsupervised (Principal Component Analysis) and supervised (Partial Least Squares Discriminant Analysis) multiparametric statistical methods allowed the cocoa beans from different origins to be distinguished. The most discriminant variables identified as responsible for geographical and varietal differences were the δ(15)N and δ(13)C values of cocoa beans and some extracts and tissues. It can be shown that the isotope ratios are correlated with the altitude and precipitation conditions found in the different cocoa-growing regions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A new large solid angle multi-element silicon drift detector system for low energy X-ray fluorescence spectroscopy

    Science.gov (United States)

    Bufon, J.; Schillani, S.; Altissimo, M.; Bellutti, P.; Bertuccio, G.; Billè, F.; Borghes, R.; Borghi, G.; Cautero, G.; Cirrincione, D.; Fabiani, S.; Ficorella, F.; Gandola, M.; Gianoncelli, A.; Giuressi, D.; Kourousias, G.; Mele, F.; Menk, R. H.; Picciotto, A.; Rachevski, A.; Rashevskaya, I.; Sammartini, M.; Stolfa, A.; Zampa, G.; Zampa, N.; Zorzi, N.; Vacchi, A.

    2018-03-01

    Low-energy X-ray fluorescence (LEXRF) is an essential tool for bio-related research of organic samples, whose composition is dominated by light elements. Working at energies below 2 keV and being able to detect fluorescence photons of lightweight elements such as carbon (277 eV) is still a challenge, since it requires in-vacuum operations to avoid in-air photon absorption. Moreover, the detectors must have a thin entrance window and collect photons at an angle of incidence near 90 degrees to minimize the absorption by the protective coating. Considering the low fluorescence yield of light elements, it is important to cover a substantial part of the solid angle detecting ideally all emitted X-ray fluorescence (XRF) photons. Furthermore, the energy resolution of the detection system should be close to the Fano limit in order to discriminate elements whose XRF emission lines are often very close within the energy spectra. To ensure all these features, a system consisting of four monolithic multi-element silicon drift detectors was developed. The use of four separate detector units allows optimizing the incidence angle on all the sensor elements. The multi-element approach in turn provides a lower leakage current on each anode, which, in combination with ultra-low noise preamplifiers, is necessary to achieve an energy resolution close to the Fano limit. The potential of the new detection system and its applicability for typical LEXRF applications has been proved on the Elettra TwinMic beamline.

  4. Traceability of Opuntia ficus-indica L. Miller by ICP-MS multi-element profile and chemometric approach.

    Science.gov (United States)

    Mottese, Antonio Francesco; Naccari, Clara; Vadalà, Rossella; Bua, Giuseppe Daniel; Bartolomeo, Giovanni; Rando, Rossana; Cicero, Nicola; Dugo, Giacomo

    2018-01-01

    Opuntia ficus-indica L. Miller fruits, particularly 'Ficodindia dell'Etna' of Biancavilla (POD), 'Fico d'india tradizionale di Roccapalumba' with protected brand and samples from an experimental field in Pezzolo (Sicily) were analyzed by inductively coupled plasma mass spectrometry in order to determine the multi-element profile. A multivariate chemometric approach, specifically principal component analysis (PCA), was applied to individuate how mineral elements may represent a marker of geographic origin, which would be useful for traceability. PCA has allowed us to verify that the geographical origin of prickly pear fruits is significantly influenced by trace element content, and the results found in Biancavilla PDO samples were linked to the geological composition of this volcanic areas. It was observed that two principal components accounted for 72.03% of the total variance in the data and, in more detail, PC1 explains 45.51% and PC2 26.52%, respectively. This study demonstrated that PCA is an integrated tool for the traceability of food products and, at the same time, a useful method of authentication of typical local fruits such as prickly pear. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Multielement (P-Yb-Zr-Ce-Al-Ca) fiber for moderate-power laser application with enhanced photodarkening resistivity

    Energy Technology Data Exchange (ETDEWEB)

    Dhar, Anirban; Paul, Mukul Chandra [CSIR-Central Glass and Ceramic Research Institute, 196 Raja S. C. Mullick Road, Jadavpur, Kolkata 700 032 (India); Das, Shyamal; Reddy, Pinninty Harshavardhan; Siddiki, Salim H.; Dutta, Debjit; Pal, Mrinmay [Academy of Scientific and Innovative Research (AcSIR), CSIR-CGCRI Campus, Kolkata 700 032 (India); Kir' yanov, Alexander V. [Centro de Investigaciones en Optica, Loma del Bosque 115, Col. Lomas del Campestre, Leon 37150, Guanajuato (Mexico)

    2017-06-15

    Multielement (ME) (P-Yb-Zr-Ce-Al-Ca) nanophase separated silica-glass-based optical fiber is fabricated through a conventional-modified chemical vapor deposition (MCVD) process, coupled with solution doping technique. The lasing and photodarkening behaviors of this ME fiber have been demonstrated and compared, in terms of its photodarkening (PD) performance at moderate pump powers (tens of Watts), with standard Yb-doped fiber with phospho-alumino-silicate (PAS) glass composition, which clearly reveals that the ME-Yb doped fiber is a promising candidate for laser applications with enhanced PD resistivity. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Determination of toxic and trace elements in human hair and sediment samples by reactor neutron activation analysis technique based-on the k-zero method

    International Nuclear Information System (INIS)

    Ho Manh Dung; Nguyen Mong Sinh; Nguyen Thanh Binh; Cao Dong Vu; Nguyen Thi Si

    2004-01-01

    The analysis of human hair can evaluate the degree of environmental pollutants exposure to human body, intakes of food and metabolism. Also, the analysis of sediment can aid in reconstructing the history of changes, understanding human impact on the ecosystem, and suggesting possible remedial strategies. The k o -standardization method of neutron activation analysis (k o -NAA) on research reactor is capable to play an important role as a main analytical technique with the advantages of sensitivity, precision, accuracy, multielement and routine for the sample object. Therefore, the project's aim is to build the k o -NAA procedures on the Dalat research reactor for the analysis of human hair and sediment samples. The K o -NAA procedure on the Dalat research reactor is able to determine of multielement: Ag, Al, As, Br, Ca, Cl, Co, Cr, Cu, Fe, Hg, I, K Mg, Mn, Na, S, Sb, Se, Sr, Ti, V and Zn in The human hair; and of multielement: As, Co, Cr, Cs, Fe, Hf, K, La, Mn, Na Rb, Sb, Sc, Yb and Zn in the sediment. (author)

  7. Multielement fingerprinting as a tool in origin authentication of PGI food products: Tropea red onion.

    Science.gov (United States)

    Furia, Emilia; Naccarato, Attilio; Sindona, Giovanni; Stabile, Gaetano; Tagarelli, Antonio

    2011-08-10

    Tropea red onion ( Allium cepa L. var. Tropea) is among the most highly appreciated Italian products. It is cultivated in specific areas of Calabria and, due to its characteristics, was recently awarded with the protected geographical indications (PGI) certification from the European Union. A reliable classification of onion samples in groups corresponding to "Tropea" and "non-Tropea" categories is now available to the producers. This important goal has been achieved through the evaluation of three supervised chemometric approaches. Onion samples with PGI brand (120) and onion samples not cultivated following the production regulations (80) were digested by a closed-vessel microwave oven system. ICP-MS equipped with a dynamic reaction cell was used to determine the concentrations of 25 elements (Al, Ba, Ca, Cd, Ce, Cr, Dy, Eu, Fe, Ga, Gd, Ho, La, Mg, Mn, Na, Nd, Ni, Pr, Rb, Sm, Sr, Tl, Y, and Zn). The multielement fingerprint was processed using linear discriminant analysis (LDA) (standard and stepwise), soft independent modeling of class analogy (SIMCA), and back-propagation artificial neural network (BP-ANN). The cross-validation procedure has shown good results in terms of the prediction ability for all of the chemometric models: standard LDA, 94.0%; stepwise LDA, 94.5%; SIMCA, 95.5%; and BP-ANN, 91.5%.

  8. A positive and multi-element conserving time stepping scheme for biogeochemical processes in marine ecosystem models

    Science.gov (United States)

    Radtke, H.; Burchard, H.

    2015-01-01

    In this paper, an unconditionally positive and multi-element conserving time stepping scheme for systems of non-linearly coupled ODE's is presented. These systems of ODE's are used to describe biogeochemical transformation processes in marine ecosystem models. The numerical scheme is a positive-definite modification of the Runge-Kutta method, it can have arbitrarily high order of accuracy and does not require time step adaption. If the scheme is combined with a modified Patankar-Runge-Kutta method from Burchard et al. (2003), it also gets the ability to solve a certain class of stiff numerical problems, but the accuracy is restricted to second-order then. The performance of the new scheme on two test case problems is shown.

  9. Design and Fabrication of High Gain Multi-element Multi-segment Quarter-sector Cylindrical Dielectric Resonator Antenna

    Science.gov (United States)

    Ranjan, Pinku; Gangwar, Ravi Kumar

    2017-12-01

    A novel design and analysis of quarter cylindrical dielectric resonator antenna (q-CDRA) with multi-element and multi-segment (MEMS) approach has been presented. The MEMS q-CDRA has been designed by splitting four identical quarters from a solid cylinder and then multi-segmentation approach has been utilized to design q-CDRA. The proposed antenna has been designed for enhancement in bandwidth as well as for high gain. For bandwidth enhancement, multi-segmentation method has been explained for the selection of dielectric constant of materials. The performance of the proposed MEMS q-CDRA has been demonstrated with design guideline of MEMS approach. To validate the antenna performance, three segments q-CDRA has been fabricated and analyzed practically. The simulated results have been in good agreement with measured one. The MEMS q-CDRA has wide impedance bandwidth (|S11|≤-10 dB) of 133.8 % with monopole-like radiation pattern. The proposed MEMS q-CDRA has been operating at TM01δ mode with the measured gain of 6.65 dBi and minimum gain of 4.5 dBi in entire operating frequency band (5.1-13.7 GHz). The proposed MEMS q-CDRA may find appropriate applications in WiMAX and WLAN band.

  10. Progress in multi-element silicon detectors for synchrotron XRF applications

    International Nuclear Information System (INIS)

    Ludewigt, B.; Rossington, C.; Kipnis, I.; Krieger, B.

    1995-10-01

    Multi-element silicon strip detectors, in conjunction with integrated circuit pulse-processing electronics, offer an attractive alternative to conventional lithium-drifted silicon and high purity germanium detectors for high count rate, low noise synchrotron x-ray fluorescence applications. We have been developing these types of detectors specifically for low noise synchrotron applications, such as extended x-ray absorption fine structure spectroscopy, microprobe x-ray fluorescence and total reflection x-ray fluorescence. The current version of the 192-element detector and integrated circuit preamplifier, cooled to -25 degrees C with a single-stage thermoelectric cooler, achieves an energy resolution of <200 eV full width of half maximum (FWHM) per channel (at 5.9 keV, 2 μs peaking time), and each detector element is designed to handle ∼20 kHz count rate. The detector system will soon be completed to 64 channels using new application specific integrated circuit (ASIC) amplifier chips, new CAMAC (Computer Automated Measurement and Control standard) analog-to-digital converters recently developed at Lawrence Berkeley National Laboratory (LBNL), CAMAC histogramming modules, and Macintosh-based data acquisition software. We report on the characteristics of this detector system, and the work in progress towards the next generation system

  11. Multielement stoichiometry of submerged macrophytes across Yunnan plateau lakes (China).

    Science.gov (United States)

    Xing, Wei; Wu, Haoping; Shi, Qiao; Hao, Beibei; Liu, Han; Wang, Zhixiu; Liu, Guihua

    2015-05-13

    Stoichiometric homeostasis of element composition is one of the central concepts of ecological stoichiometry. We analyzed concentrations of macroelements (C, N, P, Ca, K, Mg, S), microelements (Cu, Fe, Mn, Mo, Ni, Zn) and beneficial elements (Na, Se, Si) in submerged macrophytes, water and sediments across 20 Yunnan plateau lakes. We predicted that tissue element composition in submerged macrophytes is affected by lake trophic level and taxonomy, and submerged macrophytes have weak stoichiometric homeostasis for all above 16 elements. Canonical discriminant analyses successfully discriminated among trophic level groups and taxa groups. Of all the elements, C, N, P and S most effectively discriminated among trophic level groups across 20 lakes, revealing lake trophic level mostly affect tissue macroelement composition in submerged macrophytes; while Ca, K and Se most effectively discriminated among submerged macrophytes taxa groups, suggesting taxonomy mostly affect compositions of macroelements and beneficial elements in submerged macrophytes. In addition, the stoichiometric homeostatic coefficient of 1/HCa:C for all five taxa of submerged macrophytes were less than zero, suggesting submerged macrophytes in Yunnan plateau lakes have strong Ca stoichiometric homeostasis. Our findings, not only broaden the knowledge of multielement stoichiometric homeostasis, but also help to choose most appropriate lake management strategy.

  12. Multielement Determination of Major-to Ultratrace Elements in a Cabbage, Spinach, and the Japanese Radish by ICP-AES After Acid Digestion

    OpenAIRE

    畑山, 友紀; 奴田原, 杏奈; 藤井, 和美; 西島, 基弘; ハタヤマ, ユキ; ヌタハラ, アンナ; フジイ, カズミ; ニシジマ, モトヒロ; Yuki, Hatayama; anna, Nutahara; Kazumi, Fujii; Motohiro, Nishijima

    2011-01-01

    A multi-element determination in a cabbage, spinach, and the Japanese radish was carried out by inductively coupled plasma atomic emission spectrometry (ICP). We investigated whether there was a difference in content according to the part of the vegetables. The dried vegetables (0.5g) were digested with nitric acid and with hydrogen peroxide acid in a resolution device As a result, about 9 elements were successfully determined. The values of the coefficient of variance for part interval by ea...

  13. Fast sequential multi-element determination of major and minor elements in environmental samples and drinking waters by high-resolution continuum source flame atomic absorption spectrometry.

    Science.gov (United States)

    Gómez-Nieto, Beatriz; Gismera, Ma Jesús; Sevilla, Ma Teresa; Procopio, Jesús R

    2015-01-07

    The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Multielement analysis of biological standards by neutron activation analysis

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1977-01-01

    Up to 28 elements were determined in two IAEA standards: Animal Muscle H4 and Fish Soluble A 6/74, and three NBS standards: Spinach: SRM-1570, Tomato Leaves: SRM-1573 and Pine Needles: SRM-1575 by instrumental neutron-activation analysis. Seven noble metals were determined in two NBS standards: Coal: SRM-1632 and Coal Fly Ash: SRM-1633 by radiochemical procedure while 11 rare earth elements were determined in NBS standard Orchard Leaves: SRM-1571 by instrumental neutron-activation analysis. The results are in good agreement with the certified and/or literature data where available. The irradiations were performed at the Cornell TRIGA Mark II nuclear reactor at a thermal neutron flux of 1-3x10 12 ncm -2 sec -1 . The short-lived species were determined after a 2-minute irradiation in the pneumatic rabbit tube, and the longer-lived species after an 8-hour irradiation in the central thimble facility. The standards and samples were counted on coaxial 56-cm 3 Ge(Li) detector. The system resolution was 1.96 keV (FWHM) with a peak to Compton ratio of 37:1 and counting efficiency of 13%, all compared to the 1.332 MeV photopeak of Co-60. (T.I.)

  15. Forensic neutron activation analysis

    International Nuclear Information System (INIS)

    Kishi, T.

    1987-01-01

    The progress of forensic neutron activation analysis (FNAA) in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences (e.g., paints, metal fragments, plastics and inks) and drug sample differentiation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author) 14 refs

  16. Optimization of a spectrometry for energy-dispersive x-ray fluorescence analysis by x-ray tube in combination with secondary target for multielements determination of sediment samples

    International Nuclear Information System (INIS)

    Zaidi Embong; Husin Wagiran

    1997-01-01

    The design of an energy-dispersive X-ray fluorescence spectrometer equipped with a conventional X-ray tube and secondary target is described. The spectrometer system constructed in our laboratory consists of a semiconductor detector system, irradiation chamber and X-ray tube. Primary source from X-ray tube was used to produced secondary X-ray from selenium, molybdenum and cadmium targets. The fluorescence X-ray from the sample was detected using Si(Li) detector with resolution of 0. 175 keV (Mn-K(x). The spectrometer was used for determination of multi-elements with atomic number between 20 to 44 in river sediment samples. The X-ray spectrum, from the samples were analysed using computer software which was developed based on Marquardt method. Optimal conditions and detection limits are determined experimentally by variation of excitation parameters for each combination of secondary target and tube voltage

  17. Multi-element analysis of small biological samples

    International Nuclear Information System (INIS)

    Rokita, E.; Cafmeyer, J.; Maenhaut, W.

    1983-01-01

    A method combining PIXE and INAA was developed to determine the elemental composition of small biological samples. The method needs virtually no sample preparation and less than 1 mg is sufficient for the analysis. The method was used for determining up to 18 elements in leaves taken from Cracow Herbaceous. The factors which influence the elemental composition of leaves and the possible use of leaves as an environmental pollution indicator are discussed

  18. Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2013-01-01

    RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

  19. Multielement determination and speciation of major-to-ultratrace elements in green tea leaves by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Haraguchi, Hiroki

    2000-01-01

    In order to investigate the multi-elemental composition of green tea leaves as well as chemical species in tea infusions, inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) were used for elemental analysis and elemental speciation with the aid of size exclusion chromatography (SEC). As a result, the multielement determination of major-to-ultratrace elements in green tea leaves and green tea infusions was carried out by ICP-AES and ICP-MS. About 40 elements in these tea samples could be determined in a wide concentration range of over 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusion to that in tea leaves. It was found from the experimental results that the elements in tea leaves could be classified into three characteristic groups, depending on their extraction efficiencies. Furthermore, tea infusions were analyzed by a combined system of SEC, UV absorption detector, and ICP-AES (or ICP-MS) for the speciation of major-to-ultratrace elements. Most of the elements in tea infusions were found to be present as associated complexes with large organic molecules. (author)

  20. Multielement neutron activation analysis of underground water samples

    International Nuclear Information System (INIS)

    Kusaka, Yuzuru; Tsuji, Haruo; Fujimoto, Yuzo; Ishida, Keiko; Mamuro, Tetsuo.

    1980-01-01

    An instrumental neutron activation analysis by gamma-ray spectrometry with high resolution and large volume Ge (Li) detectors followed by data processing with an electronic computer was applied to the multielemental analysis to elucidate the chemical qualities of the underground water which has been widely used in the sake brewing industries in Mikage, Uozaki and Nishinomiya districts, called as miyamizu. The evaporated residues of the water samples were subjected to the neutron irradiations in reactor for 1 min at a thermal flux of 1.5 x 10 12 n.cm -2 .sec -1 and for 30 hrs at a thermal flux of 9.3 x 10 11 n.cm -2 .sec -1 or for 5 hrs at a thermal flux of 3.9 x 10 12 n.cm -2 .sec -1 . Thus, 11 elements in the former short irradiation and 38 elements in the latter two kinds of long irradiation can be analyzed. Conventional chemical analysis including atomic absorption method and others are also applied on the same samples, and putting the all results together, some considerations concerning the geochemical meaning of the analytical values are made. (author)

  1. Multielement analysis of Nigerian traditional (black) soaps

    International Nuclear Information System (INIS)

    Akanni, M.S.; Ogugbuaja, V.O.

    1985-01-01

    The element contents of some Nigerian traditional soap samples were determined using thermal neutron activation analysis. The quality control consists of replicate analyses of standard 1632A bituminous coal for precision and accuracy determination. Potassium is found to be the major element in the soaps. While some elements show fairly constant concentration in all samples analyzed, others have high maximum/minimum ratios. The elemental concentration variation in the soaps may likely have effects on their relative foaming capability and such variation is linked to the physical environment where the starting materials are obtained. (author)

  2. Multielement surface plasmon resonance immunosensor for monitoring of blood circulation system

    Science.gov (United States)

    Kostyukevych, Sergey A.; Kostyukevych, Kateryna V.; Khristosenko, Roman V.; Lysiuk, Viktor O.; Koptyukh, Anastasiya A.; Moscalenko, Nadiya L.

    2017-12-01

    The problems related to the development of a multielement immunosensor device with the prism type of excitation of a surface plasmon resonance in the Kretschmann configuration and with the scanning of the incidence angle of monochromatic light aimed at the reliable determination of the levels of three molecular markers of the system of hemostasis (fibrinogen, soluble fibrin, and D-dimer) are considered. We have analyzed the influence of a technology for the production of a gold coating, modification of its surface, and noise effects on the enhancement of sensitivity and stability of the operation of devices. A means of oriented immobilization of monoclonal antibodies on the surface of gold using a multilayer film of copper aminopentacyanoferrate is developed. For the model proteins of studied markers, the calibrating curves (maximum sensitivity of 0.5 μg/ml) are obtained, and the level of fibrinogen in blood plasma of donors is determined. A four-channel modification of the device with an application of a reference channel for comparing the elimination of the noise of temperature fluctuations has been constructed. This device allows one to execute the express-diagnostics of prethrombotic states and the monitoring of the therapy of diseases of the blood circulation system.

  3. Neutron Activation Analysis with k0 Standardization

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation aims to: (1) develop and implement k 0 -standardisation method for NAA; (2) to exploit the inherent qualities of NAA such as accuracy, traceability, and multi-element capability; (3) to acquire technical spin-off for nuclear measurements services. Main achievements in 1997 are reported

  4. Multi trace element analysis of dry biological materials by neutron activation analysis including a chemical group separation

    International Nuclear Information System (INIS)

    Weers, C.A.

    1980-07-01

    Multi-element analysis of dry biological material by neutron activation analysis has to include radiochemical separation. The evaporation process is described in terms of the half-volume. The pretreatment of the samples and the development of the destruction-evaporation apparatus are described. The successive adsorption steps with active charcoal, Al 2 O 3 and coprecipitation with Fe(OH) 3 are described. Results obtained for standard reference materials are summarized. (G.T.H.)

  5. Head of detector for multi-element analysis

    International Nuclear Information System (INIS)

    Frynta, Z.

    1983-01-01

    The detector head mounted on the scintillation counter consists of a hollow hexagonal rotary support axially arranged with the photomultiplier of the scintillation counter. In the walls of the hexagonal rotary support there are openings in which are inserted absorption filters. The mounting of the absorption filters on the rotary support allows the analysis of a greater number of elements without the dismantling of the head and the replacement of filters. The suitable geometry of the head is retained so that it is possible to insert the head into the hollows similarly as the scintillation counter. (J.P.)

  6. Parameter Optimization of Multi-Element Synthetic Aperture Imaging Systems

    Directory of Open Access Journals (Sweden)

    Vera Behar

    2007-03-01

    Full Text Available In conventional ultrasound imaging systems with phased arrays, the further improvement of lateral resolution requires enlarging of the number of array elements that in turn increases both, the complexity and the cost, of imaging systems. Multi-element synthetic aperture focusing (MSAF systems are a very good alternative to conventional systems with phased arrays. The benefit of the synthetic aperture is in reduction of the system complexity, cost and acquisition time. In a MSAF system considered in the paper, a group of elements transmit and receive signals simultaneously, and the transmit beam is defocused to emulate a single element response. The echo received at each element of a receive sub-aperture is recorded in the computer memory. The process of transmission/reception is repeated for all positions of a transmit sub-aperture. All the data recordings associated with each corresponding pair "transmit-receive sub-aperture" are then focused synthetically producing a low-resolution image. The final high-resolution image is formed by summing of the all low-resolution images associated with transmit/receive sub-apertures. A problem of parameter optimization of a MSAF system is considered in this paper. The quality of imaging (lateral resolution and contrast is expressed in terms of the beam characteristics - beam width and side lobe level. The comparison between the MSAF system described in the paper and an equivalent conventional phased array system shows that the MSAF system acquires images of equivalent quality much faster using only a small part of the power per image.

  7. Effects of Al2O3 and/or CaO on properties of yttria stabilized zirconia electrolyte doped with multi-elements

    International Nuclear Information System (INIS)

    Lv Zhengang; Guo Ruisong; Yao Pei; Dai Fengying

    2007-01-01

    Yttria stabilized zirconia (YSZ) has a high oxide ion conductivity at high temperatures. Some rare earth elements (e.g., Yb, Sc, Dy) with similar cation radii to Zr 4+ can dissolve into ZrO 2 , increasing its vacancy concentration and crystal lattice distortion, and therefore enhancing its conductivity and lowering the activation energy. It is expected this material could be used as intermediate temperature electrolyte. In the present work, YSZ electrolyte materials doped by multi-elements (Sc 2 O 3 or Dy 2 O 3 and Yb 2 O 3 ) were prepared by high temperature solid-state method. The high temperature conductivity was improved obviously, reaching 0.18 S/cm at 1000 deg. C, but the density and mechanical properties of sintered materials were not sufficiently high. It is found that sinterability and mechanical properties could be improved by inclusion of a small amount of Al 2 O 3 and/or CaO into the multi-elements doped YSZ materials and our results proved it. The results showed density and bending strength of sintered bodies were enhanced by Al 2 O 3 addition by 4.6% and 30%, respectively, while the conductivity did not degrade remarkably. But the degradation in bending strength and conductivity resulting from the CaO addition happened due to the second phase formed at the grain boundary. XRD patterns showed that all samples had cubic fluorite structure and crystalline lattice parameter was increased. SEM photographs obviously revealed the grain growth for the samples with CaO inclusion

  8. Development and characterization of multi-element doped hydroxyapatite bioceramic coatings on metallic implants for orthopedic applications

    International Nuclear Information System (INIS)

    Furko, M.; Havasi, V.; Kónya, Z.; Grünewald, D.; Detsch, R.; Boccaccini, A.R.; Balázsi, C.

    2018-01-01

    Multi-element modified bioactive hydroxyapatite bioceramic (mHAp) coatings were successfully developed onto surgical grade titanium alloy material (Ti6Al4V). The coatings were prepared by pulse current deposition from electrolyte containing adequate amounts of calcium nitrate and ammonium dihydrogen phosphate at 70C. The pure HAp layer was doped and co-deposited with Ag, Zn, Mg, Sr ions. The biocompatible properties of layers were investigated by seeding osteoblast-like MG-63 cells onto the samples’ surface. The biocompatible measurements revealed enhanced bioactivity of modified HAp compared to uncoated implant materials and pure bioceramic coating. The morphology and structure of coatings and cells were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) as well as FT-IR and XRD measurements. The biodegradable properties of samples were investigated by electrochemical potentiodynamic measurements. [es

  9. Forensic neutron activation analysis - the Japanese scene

    International Nuclear Information System (INIS)

    Kishi, Tohru.

    1986-01-01

    The progress of forensic neutron activation analysis/FNAA/ in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences /e.g.,paints, metal fragments, plastics and inks/ and drug sample differenciation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author)

  10. Methodological developments and applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    2007-01-01

    The paper reviews the author's experience acquired and achievements made in methodological developments of neutron activation analysis (NAA) of mostly biological materials. These involve epithermal neutron activation analysis, radiochemical neutron activation analysis using both single- and multi-element separation procedures, use of various counting modes, and the development and use of the self-verification principle. The role of NAA in the detection of analytical errors is discussed and examples of applications of the procedures developed are given. (author)

  11. SRXRF determination of the multielement composition of the hair and blood of the children of Tundra Nenetz population

    International Nuclear Information System (INIS)

    Chankina, O.V.; Kovalskaya, G.A.; Koutzenogii, K.P.; Osipova, L.P.; Savchenko, T.I.

    2001-01-01

    SRXRF has been used to determine the multielement composition of the hair and blood of Tundra Nenetz children. The method allows one to simultaneously determine 21 elements in the blood and 22 elements in the hair. Individual differences have been revealed in the element composition of the hair and blood. Sexual and age changes have been revealed in the content of some elements in the hair. A technique has been developed to prepare blood and hair samples for measuring the element composition by the SRXRF method. The blood samples were prepared by spreading 20 μl over the 1 cm 2 Whatman filter. The hair samples were obtained by pressing in the form of tablets of 1 cm in diameter and a mass of 10-40 mg

  12. Simultaneous analysis of multielement in Ni-electrolyte by TXRF

    International Nuclear Information System (INIS)

    Yuhong, T.; Kai, L.; Guoli, M.

    2000-01-01

    The TXRF technique is applied in our lab to analyze the sample consist of multi elements (from Na to U). Two peculiar ways, chemical and electronical, were established with high efficiency to determine the content of Fe, Co, Ni, Cu, Zn, Pb in the range of 10 2 to 10 1 μg/mL in Ni-base electrolyte in which Ni comes to about 8 x 10 4 μg/mL. Before analysis a step of reducing of Ni content was applied to decrease measurement error of trace elements in the electrolyte. The total time needed for analysis is less than 20 min. We have built a set of TXRF spectrometer on our selves. The system stands out for its short optic path, high sensitivity, low power consuming and full automation. The detection limit comes up to the order of ppb, a powerful analysis software with high flexibility, friend interface is developed by our team on the platform of Win98 under which the control system also works. Key Word TXRF spectrometer, Ni-base electrolyte, multi element analysis. (author)

  13. AC power flow importance measures considering multi-element failures

    International Nuclear Information System (INIS)

    Li, Jian; Dueñas-Osorio, Leonardo; Chen, Changkun; Shi, Congling

    2017-01-01

    Quantifying the criticality of individual components of power systems is essential for overall reliability and management. This paper proposes an AC-based power flow element importance measure, while considering multi-element failures. The measure relies on a proposed AC-based cascading failure model, which captures branch overflow, bus load shedding, and branch failures, via AC power flow and optimal power flow analyses. Taking the IEEE 30, 57 and 118-bus power systems as case studies, we find that N-3 analyses are sufficient to measure the importance of a bus or branch. It is observed that for a substation bus, its importance is statistically proportional to its power demand, but this trend is not observed for power plant buses. While comparing with other reliability, functionality, and topology-based importance measures popular today, we find that a DC power flow model, although better correlated with the benchmark AC model as a whole, still fails to locate some critical elements. This is due to the focus of DC-based models on real power that ignores reactive power. The proposed importance measure is aimed to inform decision makers about key components in complex systems, while improving cascading failure prevention, system backup setting, and overall resilience. - Highlights: • We propose a novel importance measure based on joint failures and AC power flow. • A cascading failure model considers both AC power flow and optimal power flow. • We find that N-3 analyses are sufficient to measure the importance of an element. • Power demand impacts the importance of substations but less so that of generators. • DC models fail to identify some key elements, despite correlating with AC models.

  14. The verification of neutron activation analysis support system (cooperative research)

    Energy Technology Data Exchange (ETDEWEB)

    Sasajima, Fumio; Ichimura, Shigeju; Ohtomo, Akitoshi; Takayanagi, Masaji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sawahata, Hiroyuki; Ito, Yasuo [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology; Onizawa, Kouji [Radiation Application Development Association, Tokai, Ibaraki (Japan)

    2000-12-01

    Neutron activation analysis support system is the system in which even the user who has not much experience in the neutron activation analysis can conveniently and accurately carry out the multi-element analysis of the sample. In this verification test, subjects such functions, usability, precision and accuracy of the analysis and etc. of the neutron activation analysis support system were confirmed. As a method of the verification test, it was carried out using irradiation device, measuring device, automatic sample changer and analyzer equipped in the JRR-3M PN-3 facility, and analysis software KAYZERO/SOLCOI based on the k{sub 0} method. With these equipments, calibration of the germanium detector, measurement of the parameter of the irradiation field and analysis of three kinds of environmental standard sample were carried out. The k{sub 0} method adopted in this system is primarily utilized in Europe recently, and it is the analysis method, which can conveniently and accurately carried out the multi-element analysis of the sample without requiring individual comparison standard sample. By this system, total 28 elements were determined quantitatively, and 16 elements with the value guaranteed as analytical data of the NIST (National Institute of Standards and Technology) environment standard sample were analyzed in the accuracy within 15%. This report describes content and verification result of neutron activation support system. (author)

  15. A Study of Two Multi-Element Resonant DC-DC Topologies with Loss Distribution Analyses

    Directory of Open Access Journals (Sweden)

    Yifeng Wang

    2017-09-01

    Full Text Available In this paper, two multi-element resonant DC-DC converters are analyzed in detail. Since their resonant tanks have multiple resonant components, the converters display different resonant characteristics within different operating frequency ranges. Through appropriate design, both of the two proposed converters successfully lower the conversion losses and, meanwhile, broaden the voltage gain ranges as well: one converter is able to take full usage of the third order harmonic to deliver the active power, and thus the effective utilization rate of the resonant current is elevated; while the another minimizes the entire switching losses for power switching devices by restricting the input impedance angle of the resonant tank. Besides, the loss distribution is analyzed for the purpose of guiding the component design. In the end, two 500 W prototypes are fabricated to test the theoretical analyses. The results demonstrate that the two proposed converters can achieve wide voltage gain with the small frequency deviation, which noticeably contributes to highly efficient conversion. Their peak efficiencies are measured as 95.4% and 95.3%, respectively.

  16. Analysis of atmospheric particulate samples via instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    1990-01-01

    Instrumental neutron activation analysis (INAA) is a powerful analytical technique for the elemental characterization of atmospheric particulate samples. It is a true multielement technique with adequate sensitivity to determine 30 to 40 elements in a sample of atmospheric particulate material. Its nondestructive nature allows sample reanalysis by the same or a different analytical technique. In this paper as an example of the applicability of INAA to the study of atmospheric particulate material, a study of the emissions from municipal incinerators is described

  17. MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION TO ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP�MS)

    Science.gov (United States)

    Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri

    2013-01-01

    A new chelating resin has been synthesized by immobilizing 4–(2–thiazolylazo) resorcinol (TAR) onto styrene divinlybenzene copolymer and examined for on-line solid phase extraction/preconcentration of Cd, Co, Cu, Ni, Pb and Zn in seawater and fish otoliths for determination by inductively plasma mass spectrometry (ICP-MS). A volume of 5.0 mL sample solution was loaded onto the mini column of TAR immobilized resin at 2.0 mL min−1 via a sequential injection system. The optimum pH for multielement preconcentration was around pH 5.5. Recoveries were better than 96% in artificial seawater. Elution was achieved with 1.0 mL of 0.75 mol L−1 HNO3. The resin possesses large sorption capacity ranging from 82.0 µmol g−1 for Pb to 319 µmol g−1 for Cu. The detection limits (3s) varied between 0.0016 µg L−1 (Cd) and to 0.015 µg L−1 (Zn) for preconcentration of 5.0 mL blank solutions (pH 5.5). Relative standard deviation (RSD)for three replicate runs was between 0.3% (Cd) and 6% (Zn) at 1.0 µg L−1 level. The procedure was validated by analysis of Nearshore Seawater certified reference material (CASS–4), and then successfully applied to the determination of the trace elements in fish otoliths (CRM 22) and in coastal seawater and estuarine water samples. PMID:24976635

  18. Multi-scaling allometric analysis for urban and regional development

    Science.gov (United States)

    Chen, Yanguang

    2017-01-01

    The concept of allometric growth is based on scaling relations, and it has been applied to urban and regional analysis for a long time. However, most allometric analyses were devoted to the single proportional relation between two elements of a geographical system. Few researches focus on the allometric scaling of multielements. In this paper, a process of multiscaling allometric analysis is developed for the studies on spatio-temporal evolution of complex systems. By means of linear algebra, general system theory, and by analogy with the analytical hierarchy process, the concepts of allometric growth can be integrated with the ideas from fractal dimension. Thus a new methodology of geo-spatial analysis and the related theoretical models emerge. Based on the least squares regression and matrix operations, a simple algorithm is proposed to solve the multiscaling allometric equation. Applying the analytical method of multielement allometry to Chinese cities and regions yields satisfying results. A conclusion is reached that the multiscaling allometric analysis can be employed to make a comprehensive evaluation for the relative levels of urban and regional development, and explain spatial heterogeneity. The notion of multiscaling allometry may enrich the current theory and methodology of spatial analyses of urban and regional evolution.

  19. Absolute sensitivity calibration from 20 A to 430 A of a grazing incidence spectrometer with a multi-element spectral detector

    International Nuclear Information System (INIS)

    Terry, J.L.; Manning, H.L.; Marmar, E.S.

    1986-07-01

    Two methods which together allow sensitivity calibration from 20 A to 430 A are described in detail. The first method, useful up to 120 A, uses a low power source to generate Kα x-rays which are alternately viewed by an absolute detector (a proportional counter) and the spectrometer. The second method extends that calibration to 430 A. It relies on the 2:1 brightness ratio of bright doublet lines from impurity ions which have a single outer shell electron and which are present in hot, magnetically confined plasmas. It requires that the absolute sensitivity of the spectrometer be known at one wavelength point, and in practice requires a multi-element spectral detector

  20. Multielement analysis of water in Yodo River

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Mizohata, Akira; Matsunami, Tadao; Matsuda, Yatsuka

    1980-01-01

    Yodo River is a major source of water supplies in the Osaka district. Three tributaries including Katsura River flow into this river at close positions. It is known that the Katsura River is considerably polluted due to the sewage treatment in Kyoto City. Following the previous survey in September, 1970, a similar survey by neutron activation has been carried out on the pollution of the Yodo River in October, 1977, by increasing the number of sampling points. Because it is reported that the pollution of the Katsura River has been largely lowered from that in the previous survey, the purpose was to grasp the present situation of the water pollution of the Yodo River due to metal elemens and others, and further to examine in relation of material balance. The procedures used were, first, the evaporation and solidification of sample water, and then neutron activation analysis. The correlation among the concentrations of elements, the pattern of the concentrations of elements, the material balance along the Yodo River, etc. are described in this paper. (J.P.N.)

  1. Delineation of geochemical anomalies based on stream sediment data utilizing fractal modeling and staged factor analysis

    Science.gov (United States)

    Afzal, Peyman; Mirzaei, Misagh; Yousefi, Mahyar; Adib, Ahmad; Khalajmasoumi, Masoumeh; Zarifi, Afshar Zia; Foster, Patrick; Yasrebi, Amir Bijan

    2016-07-01

    Recognition of significant geochemical signatures and separation of geochemical anomalies from background are critical issues in interpretation of stream sediment data to define exploration targets. In this paper, we used staged factor analysis in conjunction with the concentration-number (C-N) fractal model to generate exploration targets for prospecting Cr and Fe mineralization in Balvard area, SE Iran. The results show coexistence of derived multi-element geochemical signatures of the deposit-type sought and ultramafic-mafic rocks in the NE and northern parts of the study area indicating significant chromite and iron ore prospects. In this regard, application of staged factor analysis and fractal modeling resulted in recognition of significant multi-element signatures that have a high spatial association with host lithological units of the deposit-type sought, and therefore, the generated targets are reliable for further prospecting of the deposit in the study area.

  2. The monostandard method in thermal neutron activation analysis of geological, biological and environmental materials

    International Nuclear Information System (INIS)

    Alian, A.; Djingova, R.G.; Kroener, B.; Sansoni, B.

    1984-01-01

    A simple method is described for instrumental multielement thermal neutron activation analysis using a monostandard. For geological and air dust samples, iron is used as a comparator, while sodium has advantages for biological materials. To test the capabilities of this method, the values of the effective cross sections of the 23 elements determined were evaluated in a reactor site with an almost pure thermal neutron flux of about 9x10 12 nxcm -2 xs -1 and an epithermal neutron contribution of less than 0.03%. The values obtained were found to agree mostly well with the best literature values of thermal neutron cross sections. The results of an analysis by activation in the same site agree well with the relative method using multielement standards and for several standard reference materials with certified element contents. A comparison of the element contents obtained by the monostandard and relative methods together with corresponding precisions and accuracies is given. (orig.) [de

  3. Improving the effectiveness of geological prospecting with neutron activation analysis

    International Nuclear Information System (INIS)

    Fardy, J.J.

    1984-01-01

    Two examples of the use of neutron activation analysis to improve the effectiveness of geological prospecting are examined. The first is application to the direct hydrogeochemical prospecting for gold in surface waters. The second shows how multielement data banks produced by NAA for a geological formation provide a powerful method for the classification of ore bodies and sedimentary materials

  4. Multi-element characterization and source identification of trace metal in road dust from an industrial city in semi-humid area of Northwest China

    International Nuclear Information System (INIS)

    Mengmeng Zhang; Xinwei Lu; Hao Chen; Panpan Gao; Yi Fu

    2015-01-01

    Concentrations and sources of multi-elements in road dusts from an industrial city of northwest China were determined. Dust samples have elevated concentrations of Co, Cr, Cu, Pb, Zn, Sr and Ba. The dusts were mainly moderate enrichment by Co and Pb, minimal enrichment to moderate enrichment by Sr and Zn, and deficiency to minimal enrichment by other trace metals. Mn, V, Y, La, Hf, Th and U originated from soil. Cu, Pb, Cr, Ba and Sr mainly derived from traffic. Co, Zr, Ni, Ga, As and Zn have mixed sources of nature, industry and traffic. (author)

  5. Multielement analysis of foods and related materials by NAA

    International Nuclear Information System (INIS)

    Cunningham, W.C.; Anderson, D.L.

    1992-01-01

    This paper presents FDA's use of prompt- and delayed-gamma thermal neutron activation analysis (PGAA and INAA, respectively), collectively referred to here is NAA, for the analysis of foods. Several elements of nutritional or toxicological importance can be simultaneously determined at levels ranging from trace to percent. Concentrations of aluminum, boron, bromine, calcium, chlorine, hydrogen, potassium, magnesium, manganese, nitrogen, sodium, and sulfur can be determined in < 1 day in most foods. For INAA, after a few weeks of decay following irradiation, cobalt, cesium, iron, rubidium, scandium, and zinc can also be determined. Other elements that are detectable in only some food types include cadmium, chromium, copper, iodine, phosphorus, antimony, selenium, titanium, and vanadium

  6. Experimental Combustion Dynamics Behavior of a Multi-Element Lean Direct Injection (LDI) Gas Turbine Combustor

    Science.gov (United States)

    Acosta, Waldo A.; Chang, Clarence T.

    2016-01-01

    An experimental investigation of the combustion dynamic characteristics of a research multi-element lean direct injection (LDI) combustor under simulated gas turbine conditions was conducted. The objective was to gain a better understanding of the physical phenomena inside a pressurized flametube combustion chamber under acoustically isolated conditions. A nine-point swirl venturi lean direct injection (SV-LDI) geometry was evaluated at inlet pressures up to 2,413 kPa and non-vitiated air temperatures up to 867 K. The equivalence ratio was varied to obtain adiabatic flame temperatures between 1388 K and 1905 K. Dynamic pressure measurements were taken upstream of the SV-LDI, in the combustion zone and downstream of the exit nozzle. The measurements showed that combustion dynamics were fairly small when the fuel was distributed uniformly and mostly due to fluid dynamics effects. Dynamic pressure fluctuations larger than 40 kPa at low frequencies were measured at 653 K inlet temperature and 1117 kPa inlet pressure when fuel was shifted and the pilot fuel injector equivalence ratio was increased to 0.72.

  7. An adaptive multi-element probabilistic collocation method for statistical EMC/EMI characterization

    KAUST Repository

    Yücel, Abdulkadir C.

    2013-12-01

    An adaptive multi-element probabilistic collocation (ME-PC) method for quantifying uncertainties in electromagnetic compatibility and interference phenomena involving electrically large, multi-scale, and complex platforms is presented. The method permits the efficient and accurate statistical characterization of observables (i.e., quantities of interest such as coupled voltages) that potentially vary rapidly and/or are discontinuous in the random variables (i.e., parameters that characterize uncertainty in a system\\'s geometry, configuration, or excitation). The method achieves its efficiency and accuracy by recursively and adaptively dividing the domain of the random variables into subdomains using as a guide the decay rate of relative error in a polynomial chaos expansion of the observables. While constructing local polynomial expansions on each subdomain, a fast integral-equation-based deterministic field-cable-circuit simulator is used to compute the observable values at the collocation/integration points determined by the adaptive ME-PC scheme. The adaptive ME-PC scheme requires far fewer (computationally costly) deterministic simulations than traditional polynomial chaos collocation and Monte Carlo methods for computing averages, standard deviations, and probability density functions of rapidly varying observables. The efficiency and accuracy of the method are demonstrated via its applications to the statistical characterization of voltages in shielded/unshielded microwave amplifiers and magnetic fields induced on car tire pressure sensors. © 2013 IEEE.

  8. Multielement analysis of interplanetary dust particles using TOF-SIMS

    Science.gov (United States)

    Stephan, T.; Kloeck, W.; Jessberger, E. K.; Rulle, H.; Zehnpfenning, J.

    1993-01-01

    Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

  9. Compact electrostatic beam optics for multi-element focused ion beams: simulation and experiments.

    Science.gov (United States)

    Mathew, Jose V; Bhattacharjee, Sudeep

    2011-01-01

    Electrostatic beam optics for a multi-element focused ion beam (MEFIB) system comprising of a microwave multicusp plasma (ion) source is designed with the help of two widely known and commercially available beam simulation codes: AXCEL-INP and SIMION. The input parameters to the simulations are obtained from experiments carried out in the system. A single and a double Einzel lens system (ELS) with and without beam limiting apertures (S) have been investigated. For a 1 mm beam at the plasma electrode aperture, the rms emittance of the focused ion beam is found to reduce from ∼0.9 mm mrad for single ELS to ∼0.5 mm mrad for a double ELS, when S of 0.5 mm aperture size is employed. The emittance can be further improved to ∼0.1 mm mrad by maintaining S at ground potential, leading to reduction in beam spot size (∼10 μm). The double ELS design is optimized for different electrode geometrical parameters with tolerances of ±1 mm in electrode thickness, electrode aperture, inter electrode distance, and ±1° in electrode angle, providing a robust design. Experimental results obtained with the double ELS for the focused beam current and spot size, agree reasonably well with the simulations.

  10. Examination of an Antecedent Communication Intervention to Reduce Tangibly Maintained Challenging Behavior: A Controlled Analog Analysis

    Science.gov (United States)

    O'Reilly, Mark; Fragale, Christina; Gainey, Summer; Kang, Soyeon; Koch, Heather; Shubert, Jennifer; El Zein, Farah; Longino, Deanna; Chung, Moon; Xu, Ziwei; White, Pamela; Lang, Russell; Davis, Tonya; Rispoli, Mandy; Lancioni, Giulio; Didden, Robert; Healy, Olive; Kagohara, Deborah; van der Meer, Larah; Sigafoos, Jeff

    2012-01-01

    We examined the influence of an antecedent communication intervention on challenging behavior for three students with developmental disorders. Students were taught to request tangible items that were identified as reinforcers for challenging behavior in a prior functional analysis. Individual participant multielement and reversal designs were used…

  11. Forensic and archaeological applications of neutron activation analysis. Part of a coordinated programme on nuclear detection and analysis

    International Nuclear Information System (INIS)

    Sankar Das, M.

    1977-11-01

    The work carried out can be categorized as follows: setting up and standardization of the instrumental multielement analysis facility, for which a system manual is attached; forensic applications which have included the examination of firearm discharge residues around holes suspected to have been caused by the passage of a bullet, and the trace element characterization of biological (hair) and non-biological (transmission wires) materials; archaeological applications involving the study of potsherds from sites along the Stulej river in India; analysis of IAEA intercomparison samples, for which the results are tabulated; and methods for data evaluation

  12. A New Concept of Two-Stage Multi-Element Resonant-/Cyclo-Converter for Two-Phase IM/SM Motor

    Directory of Open Access Journals (Sweden)

    Mahmud Ali Rzig Abdalmula

    2013-01-01

    Full Text Available The paper deals with a new concept of power electronic two-phase system with two-stage DC/AC/AC converter and two-phase IM/PMSM motor. The proposed system consisting of two-stage converter comprises: input resonant boost converter with AC output, two-phase half-bridge cyclo-converter commutated by HF AC input voltage, and induction or synchronous motor. Such a system with AC interlink, as a whole unit, has better properties as a 3-phase reference VSI inverter: higher efficiency due to soft switching of both converter stages, higher switching frequency, smaller dimensions and weight with lesser number of power semiconductor switches and better price. In comparison with currently used conventional system configurations the proposed system features a good efficiency of electronic converters and also has a good torque overloading of two-phase AC induction or synchronous motors. Design of two-stage multi-element resonant converter and results of simulation experiments are presented in the paper.

  13. Synthetic multi-element standards: a good tool for calibration and quality control of irradiation facilities used for neutron activation analysis

    International Nuclear Information System (INIS)

    Vermaercke, P.

    2007-01-01

    determined by the nuclear cross sections. The cross sections depend on the neutron energy E and also these physical properties are parameterised in the k0-NAA method resulting in the so-called k0-factors for each element and for the different isotopes of an element. The quantification of an element then involves the use of a ratio of k0-factors in which one k0-factor is the one for 198Au. In practice, ratios of k0-factors accounting for the energy spectrum of the neutrons (f, a) are used in an analysis. These ratios are called the comparator factor FC. It is clear that the quality assurance of the k0-NAA method requires the control of the parameters f and a for each irradiation of samples. This is generally realised by using several flux monitors e.g. a set of Zr and Au monitors which are co-irradiated with the samples to analyse. However, this approach is quite labour intensive and recently we started investigating an approach based on co-irradiation of Synthetic Multi-Element Standards (SMELS) for this purpose. SMELS contain different elements in known concentrations, and three types of materials exist: Type I (elements forming short-lived radionuclides), Type II (elements forming medium lived radionuclides) and Type III (elements forming long lived radionuclides). Au was added to all three SMELS types and Zr in type III. The objectives are to optimise the ratio of quality of analysis to workload by appropriate quality control methods to determine and monitor the irradiation parameters (f, a) using SMELS and to set up a Quality Control (QC) system for the complete measurement and analysis process for k0-NAA

  14. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Asubiojo, O.I.; Guinn, V.P.

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis. (author)

  15. Multielement determination of major-to-ultratrace elements in salmon egg by ICP-AES and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Hirotaka; Haraguchi, Hiroki [Nagoya Univ., Graduate School of Engineering, Dept. of Applied Chemistry, Nagoya, Aichi (Japan)

    2002-04-01

    The multielement determination of major-to-ultratrace elements in salmon egg was carried out by ICP-AES and ICP-MS. First, salmon eggs (30 eggs used) were digested with conc. nitric acid and 60% perchloric acid by heating almost to dryness repeatedly. Finally, the residues of salmon eggs were dissolved in 1 M nitric acid and the sample solutions were analyzed by ICP-AES and ICP-MS. About 40 elements could be determined over the concentration range in 9 orders of magnitude. The concentrations of bio-essential elements, such as Zn, Fe, and Cu, in salmon egg were 10-100 times higher than those in human blood serum. In addition, the major-to-ultratrace elements in cell cytoplasm and cell membrane were separately determined in a similar manner to those in whole egg cell. The concentrations of most bio-essential elements were higher in cell cytoplasm than in cell membrane, while those of Fe and Cu were higher in cell membrane than in cell cytoplasm of salmon egg. (author)

  16. A highly rationalized procedure of neutron activation analysis for routine applications in dairy science

    International Nuclear Information System (INIS)

    Heine, K.; Wiechen, A.

    1976-01-01

    A rational procedure was developed for the multi-element analysis by neutron activation for applications in dairy science. The preparation of samples prior to irradiation consists of drying, weighing, and welding in quartz ampoules. The neutron flux, samples are exposed to during reactor irradiation , is determined by the mono-comparator technique for which the Co-content of a commercial aluminium foil was chosen as the flux monitor. Constancy of the Co-content and uncomplicated handling of the foil essentially simplify the determination of flux. The samples are irradiated for 72 h, dissolved in HNO 3 /H 2 SO 4 and measured in the liquid state after waiting times of 1-2, 4 and 8 weeks by a Ge(Li)-detector and a 4,096 channel spectrometer. The procedure was confirmed by investigations of the biological KALE standard and by participation in inter-comparisons of biological substances of the Analytical Quality Control Service of the IAEA for the analysis of the elements Na, Ca, Cr, Fe, Co, Zn, Se, Rb, and Cs. So a procedure was developed suitable for routine multi-element analysis of biologic samples by optimizing and rationalizing all analytical steps. (orig./MG) [de

  17. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Asubiojo, O.I.; Guinn, V.P. (California Univ., Irvine (USA). Dept. of Chemistry); Okunuga, A. (California Polytechnic Univ., Pomona, CA (USA))

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis.

  18. The Multi-Element Electronstatic Lens Systems for Controlling and Focusing Charged Particle

    International Nuclear Information System (INIS)

    Sise, O.

    2004-01-01

    Particle optics are very close anolog of photon optics and most of the principles of an barged particle beam can be understood by thinking of the particles as rays of light. There are similar behaviours between particle and photon optics in controlling beams of light and charged particles, such as lenses and mirrors. Extensive information about the properties of charged particle optics, from which appropriate systems can be designed for any specific problem. In this way electrostatic lens systems are used to control beams of c/iarged particle with various energy and directions in several fields, for example electron microscopy, cathode ray tubes, ion accelerators and electron impact studies. In an electrostatic lens system quantative information is required over a wide energy range and a zoom-type of optics is needed. If the magnification is to remain constant over a wide range of energies, quite complicated electrostatic lens systems are required, .containing three, four, five, or even more lens elements. We firstly calculated the optical properties of three and four element cylinder electrostatic lenses with the help of the SIMION and LENSYS programs and developed the method for the calculation of the focal properties of five and more element lenses with afocal mode. In this method we used the combination of three and four element lenses to derive focal properties of multi-element lenses and presented this data over a wide range of energy

  19. Development of multielement neutron-capture prompt γ-rays activation analysis method

    International Nuclear Information System (INIS)

    Liu Yuren; Xie Yali; Zhao Yunzhi; Liu Jiping; Meng Bonian

    1998-01-01

    The relationship between content of the measured elements and area of typical peaks of prompt γ-rays is presented. The root-mean square errors on both the regression value of instrumentation analysis and chemical analysis for some common elements are lower than 0.5wt%. Function of the slowing body was found and analysis sensitivity was enhanced obviously in the iron ore analysis. The FWHM of the spectrometer for the H prompt γ-ray peak (2.223 MeV) is 3 keV

  20. Multi-element neutron activation analysis of Brazilian coal samples

    International Nuclear Information System (INIS)

    Atalla, L.T.; Requejo, C.S.

    1982-09-01

    The elements U, Th, La, Ce, Nd, Sm, Eu, Dy, Tb, Yb, Lu, Sc, Ta, Hf, Co, Ni, Cr, Mo, Ti, V, W, In, Ga, Mn, Ba, Sr, Mg, Rb, Cs, K, Cl, Br, As, Sb, Au, Ca, Al and Fe were determined in coal samples by instrumental neutron activation analysis, by using both thermal and epithermal neutron irradiations. The irradiation times were 10 minutes and 8 or 16 hours in a position where the thermal neutron flux was about 10 12 n.cm - 2 .s - 1 and 72 non-consecutive hours for epithermal irradiation at a flux of about 10 11 n.Cm - 2 .s - 1 . After the instrumental analysis of the above mentioned elements, Zn and Se were determined with chemical separation. The relative standard deviation of, at least, 4 determinations was about + - 10% for the majority of the results. The coal samples analysed were supplied by: Cia. Estadual da Tecnologia e Saneamento Basico (CETESB-SP), Cia. de Pesquisas e Lavras Minerais (COPELMI-RS), Cia. Carbonifera Urussunga (SC), Cia. Carbonifera Prospera (SC), Cia. Carbonifera Treviso (SC), Cia. Nacional de Mineracao de Carvao do Barro Branco (SC) and Comissao Nacional de Energia Nuclear (CNEN-RJ). (Author) [pt

  1. Multielement proton activation analysis: application to airborne particulate matter

    International Nuclear Information System (INIS)

    Priest, P.; Devillers, M.; Desaedeleer, G.

    1980-01-01

    Proton activation analysis in the range of 25 to 30 MeV proton energies allows the determination of Na, Mg, Ca, Ti, Fe, Zn, As, Sr, Sn and Pb in airborne particles collected by 4 to 7 stage impactors. Under normal, not limitative irradiation and counting conditions, the determination is accurate for samples collected from 1 to 10 m 3 of air in rural atmospheres

  2. A competitive interaction theory of attentional selection and decision making in brief, multielement displays.

    Science.gov (United States)

    Smith, Philip L; Sewell, David K

    2013-07-01

    We generalize the integrated system model of Smith and Ratcliff (2009) to obtain a new theory of attentional selection in brief, multielement visual displays. The theory proposes that attentional selection occurs via competitive interactions among detectors that signal the presence of task-relevant features at particular display locations. The outcome of the competition, together with attention, determines which stimuli are selected into visual short-term memory (VSTM). Decisions about the contents of VSTM are made by a diffusion-process decision stage. The selection process is modeled by coupled systems of shunting equations, which perform gated where-on-what pathway VSTM selection. The theory provides a computational account of key findings from attention tasks with near-threshold stimuli. These are (a) the success of the MAX model of visual search and spatial cuing, (b) the distractor homogeneity effect, (c) the double-target detection deficit, (d) redundancy costs in the post-stimulus probe task, (e) the joint item and information capacity limits of VSTM, and (f) the object-based nature of attentional selection. We argue that these phenomena are all manifestations of an underlying competitive VSTM selection process, which arise as a natural consequence of our theory. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  3. Large Sample Neutron Activation Analysis: A Challenge in Cultural Heritage Studies

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Tzika, F.

    2007-01-01

    Large sample neutron activation analysis compliments and significantly extends the analytical tools available for cultural heritage and authentication studies providing unique applications of non-destructive, multi-element analysis of materials that are too precious to damage for sampling purposes, representative sampling of heterogeneous materials or even analysis of whole objects. In this work, correction factors for neutron self-shielding, gamma-ray attenuation and volume distribution of the activity in large volume samples composed of iron and ceramic material were derived. Moreover, the effect of inhomogeneity on the accuracy of the technique was examined

  4. Multielement analysis of iliac crest bone by neutron activation

    International Nuclear Information System (INIS)

    Aras, N.K.; Yilmaz, G.; Korkusuz, F.; Olmez, I.; Sepici, B.; Eksioglu, F.; Bode, P.

    2000-01-01

    Bone samples from iliac crest were obtained from apparently healthy female (n = 4) and male (n = 8) subjects with ages between 15-50. Cortical and trabecular parts were separated and soft tissues like fat, muscle and blood were removed. Calcium, Mg, Na, Cl, Fe, Zn, Br, Sr, and Cs were determined by instrumental neutron activation analysis and other techniques, and their relations were discussed. Fairly good agreement was obtained with literature data. These values may serve as reference values for subjects from a Turkish population. (author)

  5. Dose determination algorithms for a nearly tissue equivalent multi-element thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Moscovitch, M.; Chamberlain, J.; Velbeck, K.J.

    1988-01-01

    In a continuing effort to develop dosimetric systems that will enable reliable interpretation of dosimeter readings in terms of the absorbed dose or dose-equivalent, a new multi-element TL dosimeter assembly for Beta and Gamma dose monitoring has been designed. The radiation-sensitive volumes are four LiF-TLD elements, each covered by its own unique filter. For media-matching, care has been taken to employ nearly tissue equivalent filters of thicknesses of 1000 mg/cm 2 and 300 mg/cm 2 for deep dose and dose to the lens-of-the-eye measurements respectively. Only one metal filter (Cu) is employed to provide low energy photon discrimination. A Thin TL element (0.09 mm thick) is located behind an open window designed to improve the energy under-response to low energy beta rays and to provide closer estimate of the shallow dose equivalent. The deep and shallow dose equivalents are derived from the correlation of the response of the various TL elements to the above quantities through computations based on previously defined relationships obtained from experimental results. The theoretical formalization for the dose calculation algorithms is described in detail, and provides a useful methodology which can be applied to different tissue-equivalent dosimeter assemblies. Experimental data has been obtained by performing irradiation according to the specifications established by DOELAP, using 27 types of pure and mixed radiation fields including Cs-137 gamma rays, low energy photons down to 20 keV, Sr/Y-90, Uranium, and Tl-204 beta particles

  6. Utilization of minicomputer in the radiocarbon analysis measurements

    International Nuclear Information System (INIS)

    Szarka, J.; Krnac, S.

    1984-01-01

    Possibilities of minicomputer applications for radiocarbon analysis with multielement proportional counters are considered. Off-line on-line measuring system operation is possible. TPA-70 minicomputer and CAMAC electronics are used in on-line operation. Block-diagrams of data acquisition and data processing as well as the block-diagram of data evaluation program, which permits not only to increase the precision of the measurements, but also reduces the measuring time by 1/3, as compared with conventional methods, are given

  7. Features of the use of charge-coupled devices in emission spectroscopic analysis

    International Nuclear Information System (INIS)

    Livshits, A.M.; Peleznev, A.V.

    1993-01-01

    Multielement radiation receivers based on linear charge-coupled photodiode devices have become more aand more widely used recently in spectroscopic analysis. The main feature of such receivers is their ability to record not only the intensity of the incident light flux, but also its spatial distribution. This article considers the advantages and disadvantages of charge-coupled devices when used in emission spectroscopic analysis. The main methods nd devices employed for this purpose and discussed here can be divided into four types: photographic photometry, visual styloscopy, quantometry, and successive analysis. 4 refs., 1 fig

  8. Scattering of the field of a multi-element phased array by human ribs

    Science.gov (United States)

    Gélat, P.; ter Haar, G.; Saffari, N.

    2012-03-01

    The efficacy of high intensity focused ultrasound (HIFU) for the non-invasive treatment of cancer has been demonstrated for a range of different cancers including those of the liver, kidney, prostate and breast. As a non-invasive focused therapy, HIFU offers considerable advantages over other techniques such as chemotherapy and surgical resection, in terms of invasiveness and risk of harmful side effects. Despite its advantages, however, there are a number of significant challenges currently hindering its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the ribcage to induce tissue necrosis at the required foci whilst minimising the formation of side lobes. Multielement random arrays are currently showing great promise in overcoming the limitations of single-element transducers. Nevertheless, successfully treating a patient for liver tumours requires a thorough understanding of the way in which the ultrasonic pressure field from a HIFU array is scattered by the ribcage. A mesh of quadratic pressure patches was generated using CT scan data for ribs nine to twelve on the right side. A boundary element approach based on a Generalised Minimal Residual (GMRES) implementation of the Burton-Miller formulation was used, in conjunction with phase conjugation techniques to focus the field of a 256-element random HIFU array past the ribs at both intercostal and transcostal treatment locations. This method has the advantage of accounting for full effects of scattering and diffraction in three dimensions under continuous wave excitation.

  9. Visuo-perceptual capabilities predict sensitivity for coinciding auditory and visual transients in multi-element displays.

    Science.gov (United States)

    Meyerhoff, Hauke S; Gehrer, Nina A

    2017-01-01

    In order to obtain a coherent representation of the outside world, auditory and visual information are integrated during human information processing. There is remarkable variance among observers in the capability to integrate auditory and visual information. Here, we propose that visuo-perceptual capabilities predict detection performance for audiovisually coinciding transients in multi-element displays due to severe capacity limitations in audiovisual integration. In the reported experiment, we employed an individual differences approach in order to investigate this hypothesis. Therefore, we measured performance in a useful-field-of-view task that captures detection performance for briefly presented stimuli across a large perceptual field. Furthermore, we measured sensitivity for visual direction changes that coincide with tones within the same participants. Our results show that individual differences in visuo-perceptual capabilities predicted sensitivity for the presence of audiovisually synchronous events among competing visual stimuli. To ensure that this correlation does not stem from superordinate factors, we also tested performance in an unrelated working memory task. Performance in this task was independent of sensitivity for the presence of audiovisually synchronous events. Our findings strengthen the proposed link between visuo-perceptual capabilities and audiovisual integration. The results also suggest that basic visuo-perceptual capabilities provide the basis for the subsequent integration of auditory and visual information.

  10. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    Directory of Open Access Journals (Sweden)

    Kun Lin

    2014-01-01

    Full Text Available The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The results of MECS model analysis show that the main tower in the multispan cable-stayed bridge is prone to the transverse vibration, and the local vibration of cables only has a little impact on the frequency values of the global modes. The results of simplified model analysis show that the energy can be transformed between the modes of the beam and cable when the nature frequencies of them are very close. On the other hand, with the transverse excitation changing, the cable can exhibit richer quasi-periodic or chaotic motions due to the nonlinear terms caused by the coupled mode between the beam and cable.

  11. Multi-element analysis, bioavailability and fractionation of herbal tea products

    Energy Technology Data Exchange (ETDEWEB)

    Szymczycha-Madeja, Anna; Welna, Maja; Zyrnicki, Wieslaw, E-mail: anna.szymczycha@pwr.wroc.pl [Wroclaw University of Technology, Chemistry Department, Analytical Chemistry Division, Wroclaw (Poland)

    2013-05-15

    Herbal teas (Mentha piperitae foliumand mixture Marticaria chamomilla flos with Lavandula officinalis flos) were compared considering the total contents of micro (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Ti, V) and macro (C, H, N, S, Ca, Mg, P) elements, bioavailability and fractionation. Different methods (inductively coupled plasma optical emission spectrometry (ICP OES), Fourier transform infrared spectroscopy (FTIR) and CHNS elemental analysis) were applied. The microwave-assisted digestion procedure was found to be more effective than the hot-plate heating for the wet acid digestion of tea. The application of the modified BCR (Community Bureau of Reference) sequential extraction procedure exhibited differences in the concentrations of metal bound to reducible and oxidizable fractions. The accuracy of method was verified by analysis of certified reference material INCT-TL{sup -1} Tea Leaves. The daily intake of all elements from the analyzed herbal tea infusion did not exceed the maximum permissible levels and does not constitute health risk. (author)

  12. Multi-element analysis, bioavailability and fractionation of herbal tea products

    International Nuclear Information System (INIS)

    Szymczycha-Madeja, Anna; Welna, Maja; Zyrnicki, Wieslaw

    2013-01-01

    Herbal teas (Mentha piperitae foliumand mixture Marticaria chamomilla flos with Lavandula officinalis flos) were compared considering the total contents of micro (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Ti, V) and macro (C, H, N, S, Ca, Mg, P) elements, bioavailability and fractionation. Different methods (inductively coupled plasma optical emission spectrometry (ICP OES), Fourier transform infrared spectroscopy (FTIR) and CHNS elemental analysis) were applied. The microwave-assisted digestion procedure was found to be more effective than the hot-plate heating for the wet acid digestion of tea. The application of the modified BCR (Community Bureau of Reference) sequential extraction procedure exhibited differences in the concentrations of metal bound to reducible and oxidizable fractions. The accuracy of method was verified by analysis of certified reference material INCT-TL -1 Tea Leaves. The daily intake of all elements from the analyzed herbal tea infusion did not exceed the maximum permissible levels and does not constitute health risk. (author)

  13. Instrumental neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1985-01-01

    The main characteristics of instrumental neutron activation analysis (INAA),relevant for environmental research and monitoring, was reviewed and discussed-sensitivity, suitable for detection of many toxic elements, the low risks of contamination of element loss, lack of matrix effects, lack of light element interference except for 24 Na, capability for multi-element determination, comparatively low costs. A detailed description of the IRI analysis system for routine INAA is given. The system is based on the single comparator method of standartization to take full advantage of multi-element without preparation and use the trace element standards. Zinc was used as mono element standard, the element concentrations are calculated on the basis of 65 Zn and 69m Zn-activities. The irradiations were carried out in a thermal neutron flux of 1.10 13 n/cm 2 .s. The gamma spectra is converted into element concentrations using a set of dedicated software, performing the following functions: spectrum analysis and interpretation, comparison and combination of the intermediate results from different decay times, generation of the final report, bookkeeping of the results obtained. The main applications of the INAA system mentioned are: identification of sources of heavy metal air pollution using air filters or biological indicators such as mosses, lichens, toe-nails, bird feathers, molusks and waterplants; and study of the uptake and translocation of heavy element in plants. Special attention was paid to mathematical techniques for a reliable interpretation of the element concentration patterns observed in sets of lichen samples. Future developments in INAA in environmental science are briefly mentioned

  14. Application of ion exchangers

    International Nuclear Information System (INIS)

    Markhol, M.

    1985-01-01

    Existing methods of multi-element separation for radiochemical analysis are considered. The majority of existing methods is noted to be based on application of organic and inorganic ion exchangers. Distillation, coprecipitation, extraction as well as combination of the above methods are also used. Concrete flowsheets of multi-element separation are presented

  15. Spectrometer system using a modular echelle spectrograph and a laser-driven continuum source for simultaneous multi-element determination by graphite furnace absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, Sebastian; Okruss, Michael; Becker-Ross, Helmut; Huang, Mao Dong, E-mail: huang@isas.de; Esser, Norbert; Florek, Stefan

    2015-05-01

    A multi-element absorption spectrometer system has been developed based on a laser-driven xenon continuum source and a modular simultaneous echelle spectrograph (MOSES), which is characterized by a minimized number of optical components resulting in high optical throughput, high transmittance and high image quality. The main feature of the new optical design is the multifunction usage of a Littrow prism, which is attached on a rotation stage. It operates as an order-sorter for the echelle grating in a double-pass mode, as a fine positioning device moving the echelle spectrum on the detector, and as a forwarder to address different optical components, e.g., echelle gratings, in the setup. Using different prisms, which are mounted back to back on the rotation stage, a multitude of different spectroscopic modes like broad-range panorama observations, specific UV–VIS and NIR studies or high resolution zoom investigations of variable spectral channels can be realized. In the UV panorama mode applied in this work, MOSES has simultaneously detectable wavelength coverage from 193 nm to 390 nm with a spectral resolution λ/Δλ of 55,000 (3-pixel criterion). In the zoom mode the latter can be further increased by a factor of about two for a selectable section of the full wavelength range. The applicability and the analytical performance of the system were tested by simultaneous element determination in a graphite furnace, using eight different elements. Compared to an instrument operating in the optimized single line mode, the achieved analytical sensitivity using the panorama mode was typically a factor of two lower. Using the zoom mode for selected elements, comparable sensitivities were obtained. The results confirm the influence of the different spectral resolutions. - Highlights: • Echelle spectrometer with a full frame CCD array detector • High and variable spectral resolution from λ/Δλ of 55,000 to 95,000 • Laser-driven continuum light source

  16. A site-specific and multi-element isotopic approach to origin inference of sugars in foods and beverages

    International Nuclear Information System (INIS)

    Martin, M.L.; Martin, G.J.; Guillou, C.

    1991-01-01

    A strategy is presented for the characterization of sugars according to their botanical origin. The samples fermented in standardized conditions can be described in the multi-dimensional space of the overall carbon isotope ratio of ethanol measured by isotope ratio mass spectrometry (IRMS) and of the specific hydrogen isotope parameters of the methyl and methylene sites derived from nuclear magnetic resonance investigation of site-specific natural isotope fractionation (SNIF-NMR method). In the comparison of natural juices, the deuterium and oxygen-18 parameters of water extracted from the juice and from the end fermentation medium also contain information on the origin of the product. The isotopic effects of the concentration processes leading to concentrated juices, musts and syrups can be estimated and taken into account in interpreting the data. The classification power of this multi-element and multi-site approach is illustrated by discriminant analyses involving selected isotopic variables associated with pineapple, apple and barley sugars, compared to beet and cane sugars which are common sources of enrichment. The ability of the method to detect adulteration by exogenous sugars is improved when environmental conditions can be taken into account. (authors)

  17. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  18. Improovement of statistical counting conditions for the determination of chloride in Beams leaves (Phaseolus vulgaris L.) by thermal neutron activation analysis

    International Nuclear Information System (INIS)

    Ferraz, E.S.B.; Nascimento Filho, V.F.

    1975-04-01

    The use of two radiation peaks from the same gamma-emitting source in the calculation of the corresponding liquid counting rate in multi-element gamma spectrometry is discussed. It is shown that, in the determination of chlorine in Phaseolus vulgaris L. using neutronic activation analysis will result in an increase in accuracy of measurement of approximately 40%

  19. Recent progress in the analysis of iced airfoils and wings

    Science.gov (United States)

    Cebeci, Tuncer; Chen, Hsun H.; Kaups, Kalle; Schimke, Sue

    1992-01-01

    Recent work on the analysis of iced airfoils and wings is described. Ice shapes for multielement airfoils and wings are computed using an extension of the LEWICE code that was developed for single airfoils. The aerodynamic properties of the iced wing are determined with an interactive scheme in which the solutions of the inviscid flow equations are obtained from a panel method and the solutions of the viscous flow equations are obtained from an inverse three-dimensional finite-difference boundary-layer method. A new interaction law is used to couple the inviscid and viscous flow solutions. The newly developed LEWICE multielement code is amplified to a high-lift configuration to calculate the ice shapes on the slat and on the main airfoil and on a four-element airfoil. The application of the LEWICE wing code to the calculation of ice shapes on a MS-317 swept wing shows good agreement with measurements. The interactive boundary-layer method is applied to a tapered iced wing in order to study the effect of icing on the aerodynamic properties of the wing at several angles of attack.

  20. Analysis of traces at ORNL's new high-flux neutron activation laboratory

    International Nuclear Information System (INIS)

    Ricci, E.; Handley, T.H.; Dyer, F.F.

    1974-01-01

    The investigations are outlined, which are carried out in order to develop (preferably instrumental) methods for multielement analysis of various trace elements. For this reason a new High-Flux NAA Laboratory was constructed at ORNL's. A general review is given on the Laboratory, further some methods and applications are shown. In the field of comparator activation analysis comparative data are given on mercury determinations in various matrices, and on arsenic determination in grasshoppers. This later method was used to trace the transport of arsenic containing pesticides. Some data are given on absolute activation analysis of Na, Ci, Mn, Br, and Au, too. (K.A.)

  1. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  2. The studies of post-medieval glass by multivariate and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kierzek, J.; Kunicki-Goldfinger, J.

    2002-01-01

    Multivariate statistical analysis of the results obtained by energy dispersive X-ray fluorescence analysis has been used in the study of baroque vessel glasses originated from central Europe. X-ray spectrometry can be applied as a completely non-destructive, non-sampling and multi-element method. It is very useful in the studies of valuable historical artefacts. For the last years, multivariate statistical analysis has been developed as an important tool for the archaeometric purposes. Cluster, principal component and discriminant analysis were applied for the classification of the examined objects. The obtained results show that these statistical tools are very useful and complementary in the studies of historical objects. (author)

  3. Data processing of X-ray fluorescence analysis using an electronic computer

    International Nuclear Information System (INIS)

    Yakubovich, A.L.; Przhiyalovskij, S.M.; Tsameryan, G.N.; Golubnichij, G.V.; Nikitin, S.A.

    1979-01-01

    Considered are problems of data processing of multi-element (for 17 elements) X-ray fluorescence analysis of tungsten and molybdenum ores. The analysis was carried out using silicon-lithium spectrometer with the energy resolution of about 300 eV and a 1024-channel analyzer. A characteristic radiation of elements was excited with two 109 Cd radioisotope sources, their general activity being 10 mCi. The period of measurements was 400 s. The data obtained were processed with a computer using the ''Proba-1'' and ''Proba-2'' programs. Data processing algorithms and computer calculation results are presented

  4. Neutron Activation Analysis with k0 standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    The objectives of the research are: (1) to develop and implement the k0 standardisation method for neutron activation analysis in close collaboration with scientific partners; (2) to exploit fully the inherent qualities of NAA such as accuracy, traceability, and multi-element offer complete services in health-physics measurements according to international quality standards, (2) to improve continuously these measurement techniques and to follow up international recommendations and legislation concerning the surveillance of workers; (3) to support and advise nuclear and non-nuclear industry on problems of radioactive contamination. Achievements in 1997 related to gamma spectrometry, whole-body counting, beta and alpha spectrometry, dosimetry, radon measurements, calibration, instrumentation, and neutron activation analysis are described

  5. Instrumental aspects of tube-excited energy-dispersive X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Adams, F.; Nullens, H.; Espen, P. van

    1983-01-01

    Energy-dispersive X-ray fluorescence spectrometry is an attractive and widely used method for sensitive multi-element analysis. The method suffers from the extreme density of spectral components in a rather limited energy range which implies the need for computer based spectrum analysis. The method of iterative least squares analysis is the most powerful tool for this. It requires a systematic and accurate description of the spectral features. Other important necessities for accurate analysis are the calibration of the spectrometer and the correction for matrix absorption effects in the sample; they can be calculated from available physical constants. Ours and similar procedures prove that semi-automatic analyses are possible with an accuracy of the order of 5%. (author)

  6. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  7. Advantages and disadvantages of application of inductively coupled plasma mass spectrometry for analysis of trace elements

    International Nuclear Information System (INIS)

    Kovacs, Bela; Borbely, Maria

    2011-01-01

    In this paper the advantages and disadvantages are detailed, moreover special interference effects of the examined elements are evaluated. The detection limits of different ICP-MS instruments are compared. As a result of our research work various solutions are proposed for multielement analysis (e.g. Se, I, Co, As, Te, Cd, Pb and Cr) of the above various samples to reach more accurate and more precise results using ICP-MS instrument

  8. Multielement analysis of archaic Chinese bronze and antique coins by fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y.H. (Academia Sinica, Lanzhou, Gansu (China). Inst. of Modern Physics); Pepelnik, R.; Fanger, H.U. (GKSS-Forschungszentrum Geesthacht GmbH, Geesthacht-Tesperhude (Germany, F.R.). Inst. fuer Physik)

    1990-01-01

    Samples of archaic bronze have been investigated by fast neutron activation analysis using both the absolute and relative method. The components Cu, Zn, Sn and Pb have been determined quantitatively. For the detection of lead via the short-lived isomeric state {sup 207m}Pb, cyclic activation and measurement technique was used with pneumatic sample transfer between detector and central irradiation position of the neutron tube. For non-destructive analysis of antique Chinese coins the samples had to be irradiated outside the neutron generator KORONA. The activation reactions, the evaluation of the elemental concentrations and the accuracy of the results are discussed. The data were corrected for {gamma}-ray self-absorption in the samples and summing of coincident {gamma}-rays in the detector. According to reported typical compositions of Chinese bronze from different dynasties, the age of the samples has been derived from the results obtained. (orig.).

  9. Energy dispersive X-ray fluorescence analysis with multiple total reflection

    International Nuclear Information System (INIS)

    Freitag, K.

    1985-01-01

    The development of a total reflection XRF analyzer and the performance data of this instrument are described. The drastic reduction of the scattered radiation is the outstanding property of the method. Detection limits of elements and matrix effects are discussed. The competition with other methods of analysis has proven its advantages in a wide range. In addition to its multi-element features down to the picogram level, particularly its universal calibration function has turned out to be a great help in the analytical practice. (orig./RB)

  10. Multielement ultratrace analysis in tungsten using secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Wilhartitz, P.; Virag, A.; Friedbacher, G.; Grasserbauer, M.

    1987-01-01

    The ever increasing demands on properties of materials create a trend also towards ultrapure products. Characterization of these materials is only possible with modern, highly sophisticated analytical techniques such as activation analysis and mass spectrometry, particularly SSMS, SIMS and GDMS. Analytical strategies were developed for the determination of about 40 elements in a tungsten matrix with high-performance SIMS. Difficulties like the elimination of interferences had to be overcome. Extrapolated detection limits were established in the range of pg/g (alkali metals, halides) to ng/g (e.g. Ta, Th). Depth profiling and ion imaging gave additional information about the lateral and the depth distribution of the elements. (orig.)

  11. Practical applications of activation analysis and other nuclear techniques

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    Neeutron activation analysis (NAA) is a versatile, sensitive multielement, usually nondestructive analytical technique used to determine elemental concentrations in a variety of materials. Samples are irradiated with neutrons in a nuclear reactor, removed, and for the nondestructive technique, the induced radioactivity measured. This measurement of γ rays emitted from specific radionuclides makes possible the quantitative determination of elements present. The method is described, advantages and disadvantages listed and a number of examples of its use given. Two other nuclear methods, particle induced x-ray emission and synchrotron produced x-ray fluorescence are also briefly discussed

  12. Pneumatic transport devices based on the ARS equipment set for activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.V.; Ivanets, V.N.; Rogachev, V.M.; Zakharov, E.A.

    1978-01-01

    The AGIDEL and ARS-28G facilities manufactured on the basis of a set of standardized and aggregated products for activation analysis are described. The AGIDEL is designed for automatic activation analysis of relatively homogeneous samples from oil boreholes. The ARS-28G is designed for transporting the test samples during activation analysis, using a fast-neutron generator. Structurally, the ARS-28 is based on a pneumatic transportation system with two independenhat transport cnnels and a two-channel rotating irradiation unit. The analyzed samples are transported in polyethylene containers, which are moved by compressed air. The facility has been successfully tested and is used in an automated system for multielement activation analysis

  13. Nanostructured multielement (TiHfZrNbVTa)N coatings before and after implantation of N+ ions (10{sup 18} cm{sup −2}): Their structure and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Pogrebnjak, A.D., E-mail: alexp@i.ua [Sumy State University, Department of Nanoelectronics, 40007, R.-Korsakova 2, Sumy (Ukraine); Bondar, O.V., E-mail: oleksandr.v.bondar@gmail.com [Sumy State University, Department of Nanoelectronics, 40007, R.-Korsakova 2, Sumy (Ukraine); Borba, S.O. [Sumy State University, Department of Nanoelectronics, 40007, R.-Korsakova 2, Sumy (Ukraine); Abadias, G. [Institut Pprime, CNRS, Université de Poitiers, ISAE-ENSMA, F86962 Futuroscope Chasseneuil (France); Konarski, P. [Tele and Radio Research Institute, Ratuszowa 11, 03-450 Warsaw (Poland); Plotnikov, S.V. [D. Serikbaev East-Kazakhstan State Technical University, 070004, Ust-Kamenogorsk, 69 Protozanov St. (Kazakhstan); Beresnev, V.M. [V.N. Karazin Kharkiv National University, 61022, Svobody Sq. 4, Kharkiv (Ukraine); Kassenova, L.G. [Kazakh University of Economics, Finance and International Trade, St. Zhubanov 7, 010005 Astana (Kazakhstan); Drodziel, P. [Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland)

    2016-10-15

    Highlights: • (TiZrHfVNbTa)N coatings were deposited by vacuum–arc evaporation of a cathode. • Nanostructured coatings were investigated experimentally and by MD simulations. • Good correlation between experimental data and simulation results is observed. • Ion implantation formed amorphous, nanocrystalline and nanostructured layers. • Hardness changed from 12 GPa in the implanted layer to 38 GPa with the depth. - Abstract: Multielement high entropy alloy (HEA) nitride (TiHfZrNbVTa)N coatings were deposited by vacuum arc and their structural and mechanical stability after implantation of high doses of N{sup +} ions, 10{sup 18} cm{sup −2}, were investigated. The crystal structure and phase composition were characterized by X-ray diffraction (XRD) and Transmission Electron Microscopy, while depth-resolved nanoindentation tests were used to determine the evolution of hardness and elastic modulus along the implantation depth. XRD patterns show that coatings exhibit a main phase with fcc structure, which preferred orientation varies from (1 1 1) to (2 0 0), depending on the deposition conditions. First-principles calculations reveal that the presence of Nb atoms could favor the formation of solid solution with fcc structure in multielement HEA nitride. TEM results showed that amorphous and nanostructured phases were formed in the implanted coating sub-surface layer (∼100 nm depth). Concentration of nitrogen reached 90 at% in the near-surface layer after implantation, and decreased at higher depth. Nanohardness of the as-deposited coatings varied from 27 to 38 GPa depending on the deposition conditions. Ion implantation led to a significant decrease of the nanohardness to 12 GPa in the implanted region, while it reaches 24 GPa at larger depths. However, the H/E ratio is ⩾0.1 in the sub-surface layer due to N{sup +} implantation, which is expected to have beneficial effect on the wear properties.

  14. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I.J.; Serfor-Armah, Y.; Nyarko, B.; Odamtten, G.T.

    1999-01-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard and certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done beating in mind microclimatic factors, specie type and nature of soil. (author)

  15. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I. J.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Odamtten, G.T.

    1999-04-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done bearing in mind microclimatic factors, specie type and nature of soil. (author)

  16. Neutron activation analysis of geological samples for gold and accessory elements power reactor

    International Nuclear Information System (INIS)

    Burmistrenko, Yu.N.; Medvedev, A.A.; Kovalenko, V.V.; Markov, A.V.

    1986-01-01

    Possibility of using a power reactor for neutron activation analysis to detect gold and accompanying elements in geological samples of a region was investigated. Specimens (gold-containing samples and standards) were irradiated in a spare channel for ionization chambers located outside the core in graphite reflector. Spectrometry was conducted with the help of a semiconducting detector with LP 4900 multichannel analizer. Sensitivity threshold for gold was (1-3)10 -6 % - (1-2)10 -5 %. It is shown that this method can be used not only for gold detection but for high-sensitive multielement analysis of geological samples

  17. Trace analysis for characterization of the special metals V, Mo, Ta, W, by means of activation analysis using neutrons and charged particles

    International Nuclear Information System (INIS)

    Krivan, V.; Caletka, R.; Hausbeck, R.; Schmid, W.

    1984-01-01

    Anion exchange techniques in HF containing media, or HF-NH 4 F solutions, respectively, have been determined, as well as techniques using polyurethane foams with or without impregnation, extraction techniques using crown ether in HF containing media, and a special separation method for beta-ray emitting silicon from HF solutions. A multi-element analysis by NAA in high-purity tantalum subsequent to pre-separation of the tantalum matrix is described, along with a trace analysis method by NAA in high-purity tungsten. Another new achievement is a method for determining tantalum in metals and geological materials, applying substoichiometric extraction, and the last one a method of determining silicon in vanadium and niobium. (RB) [de

  18. Prompt gamma cold neutron activation analysis applied to biological materials

    International Nuclear Information System (INIS)

    Rossbach, M.; Hiep, N.T.

    1992-01-01

    Cold neutrons at the external neutron guide laboratory (ELLA) of the KFA Juelich are used to demonstrate their profitable application for multielement characterization of biological materials. The set-up and experimental conditions of the Prompt Gamma Cold Neutron Activation Analysis (PGCNAA) device is described in detail. Results for C, H, N, S, K, B, and Cd using synthetic standards and the 'ratio' technique for calculation are reported for several reference materials and prove the method to be reliable and complementary with respect to the elements being determined by INAA. (orig.)

  19. Role of NAA in characterizations of sampling behaviors of multiple elements in CRMs

    International Nuclear Information System (INIS)

    Tian Weizhi; Ni Bangfa; Wang Pingsheng; Nie Huiling

    1997-01-01

    Taking the advantage of high precision and accuracy of neutron activation analysis (NAA), sampling constants have been determined for multielements in several international and Chinese reference materials. The suggested technique may be used for finding elements in existing CRMs qualified for quality control (QC) of small size samples (several mg or less), and characterizing sampling behaviors of multielements in new CRMs specifically made for QC of microanalysis

  20. Calibration of energy dispersive x-ray spectrometers for analysis of thin environmental samples

    International Nuclear Information System (INIS)

    Giauque, R.D.; Garrett, R.B.; Goda, L.Y.

    1976-01-01

    Four separate techniques for calibrating energy dispersive x-ray spectrometers are described. They include the use of (1) individual evaporated elemental thin-film standards, (2) nebulized multielement standard solution deposits to determine relative elemental sensitivity factors, (3) a semi-empirical approach to calculate relative elemental sensitivity factors, and (4) thick pure element disks. The first three techniques are applicable for a broad range of elements. The utilization of nebulized multielement standard solution deposits, along with an evaporated single element thin-film standard for absolute system calibration, is the most accurate method of the calibration techniques described

  1. PIXAN: the Lucas Heights PIXE analysis computer package

    International Nuclear Information System (INIS)

    Clayton, E.

    1986-11-01

    To fully utilise the multielement capability and short measurement time of PIXE it is desirable to have an automated computer evaluation of the measured spectra. Because of the complex nature of PIXE spectra, a critical step in the analysis is the data reduction, in which the areas of characteristic peaks in the spectrum are evaluated. In this package the computer program BATTY is presented for such an analysis. The second step is to determine element concentrations, knowing the characteristic peak areas in the spectrum. This requires a knowledge of the expected X-ray yield for that element in the sample. The computer program THICK provides that information for both thick and thin PIXE samples. Together, these programs form the package PIXAN used at Lucas Heights for PIXE analysis

  2. Applications of total reflection X-ray fluorescence in multi-element analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.; Knoth, J.

    1985-01-01

    Although Total Reflection X-Ray Fluorescence Analysis (TXRF) became available for practical applications and routine measurements only few years ago, the number of programmes that make use of this method is increasing rapidly. The scope of work is widespread over environmental research and monitoring, mineralogy, mineral exploration, oceanography, biology, medicine and biochemistry. The present paper gives a brief survey of these applications and summarizes some of them which are typical for quite different matrices. (orig.)

  3. Application of neutron activation analysis to the development of a monitoring system for trace metals in coastal waters

    International Nuclear Information System (INIS)

    Karbe, L.; Schnier, C.

    1976-03-01

    In view of the development of monitoring systems for trace metals in coastal waters, a research program has been started for a better understanding of interrelationships between input of trace metals, water chemistry, suspended matter, sediment and organisms. For multielement determinations neutron activation analysis has been chosen. Since environmental studies require the analysis of a large number of samples, the efficiency of the method is improved by automation of the acquisition and analysis of the γ-spectra from the Ge(Li) detectors. An automatic sample changer with counting device is described. First applications of the method in environmental research are presented. (orig.) [de

  4. Electrochemical performance of multi-element doped α-nickel hydroxide prepared by supersonic co-precipitation method

    International Nuclear Information System (INIS)

    Zhang, Z.J.; Zhu, Y.J.; Bao, J.; Lin, X.R.; Zheng, H.Z.

    2011-01-01

    Highlights: → The α-nickel hydroxides doped with several elements were prepared by supersonic co-precipitation method. → Cyclic voltammetry and electrochemical impedance spectroscopy show sample C has the best electrochemical performance. → The charge/discharge tests show that the 0.5 C discharge capacity (346 mAh/g) of sample C is even larger than that (337 mAh/g) at 0.1 C rate, while the discharge capacity at 0.5 C rate is much lower than that at 0.1 C rate for samples A and B. - Abstract: The multi-element doped α-nickel hydroxides have been prepared by supersonic co-precipitation method. Three kinds of samples A, B, C were prepared by chemically coprecipitating Ni, Al, Co, Y, Zn. It was found that sample C produced better performance than the others. The cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements indicated that sample C has better electrochemical performance, such as better reaction reversibility, higher proton diffusion coefficient and lower charge-transfer resistance, than those of samples A and B. The charge-discharge tests showed that the discharge capacity (346 mA h/g) of sample C is even larger at 0.5 C rate than that (337mAh/g) at 0.1 C rate, while the discharge capacity at 0.5 C rate is much lower than that at 0.1 C rate for samples A and B. It indicates that all doped elements can produce the synergic effect and further improve the electrochemical properties of the active materials.

  5. Effects of biochar and greenwaste compost amendments on mobility, bioavailability and toxicity of inorganic and organic contaminants in a multi-element polluted soil

    Energy Technology Data Exchange (ETDEWEB)

    Beesley, Luke, E-mail: L.Beesley@2007.ljmu.ac.u [Faculty of Science, Liverpool John Moores University, Liverpool L3 3AF (United Kingdom); Moreno-Jimenez, Eduardo [Departamento de Quimica Agricola, Universidad Autonoma de Madrid, 28049 Madrid (Spain); Gomez-Eyles, Jose L. [University of Reading, Department of Soil Science, Whiteknights, Reading RG6 6DW (United Kingdom)

    2010-06-15

    Applying amendments to multi-element contaminated soils can have contradictory effects on the mobility, bioavailability and toxicity of specific elements, depending on the amendment. Trace elements and PAHs were monitored in a contaminated soil amended with biochar and greenwaste compost over 60 days field exposure, after which phytotoxicity was assessed by a simple bio-indicator test. Copper and As concentrations in soil pore water increased more than 30 fold after adding both amendments, associated with significant increases in dissolved organic carbon and pH, whereas Zn and Cd significantly decreased. Biochar was most effective, resulting in a 10 fold decrease of Cd in pore water and a resultant reduction in phytotoxicity. Concentrations of PAHs were also reduced by biochar, with greater than 50% decreases of the heavier, more toxicologically relevant PAHs. The results highlight the potential of biochar for contaminated land remediation. - Biochar was more effective than greenwaste compost at reducing bioavailable fractions of phytotoxic Cd and Zn as well as the heavier, more toxicologically relevant PAHs.

  6. Role of NAA in determination and characterisation of sampling behaviours of multiple elements in CRMs

    International Nuclear Information System (INIS)

    Tian Weizhi; Ni Bangfa; Wang Pingsheng; Nie Huiling

    2002-01-01

    Taking the advantage of high precision and accuracy of neutron activation analysis (NAA), sampling constants have been determined for multielements in several international and Chinese reference materials. The suggested technique may be used for finding elements in existing CRMs qualified for quality control (QC) of small size samples (several mg or less), and characterizing sampling behaviors of multielements in new CRMs specifically made for QC of microanalysis. (author)

  7. Multi-element analysis of the obese subject by in vivo neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Siwek, R A; Burkinshaw, L; Oxby, C B [Leeds General Infirmary (UK); Robinson, P A.J. [Saint James' s University Hospital, Leeds (UK)

    1984-06-01

    The Leeds facility for in vivo neutron activation analysis has been modified and calibrated for the simultaneous measurement of nitrogen, potassium, sodium, chlorine, phosphorus and calcium in obese patients weighing up to 210 kg. The effects of body size and shape were incorporated into the calibration by measuring 14 anthropomorphic phantoms of known composition representing individual patients being treated for obesity. The phantoms were constructed from tissue substitutes representing lean skeletal and adipose tissues, arranged to simulate the distributions of the corresponding tissues within the patients, as visualised by CT scanning. The precision of the method, determined by measuring a single phantom ten times over a period of ten weeks, is between two and three per cent for all elements except calcium, for which it is 11.3%. Accuracy is estimated to be similar to precision. The procedure has been used to study changes in body composition of patients undergoing therapeutic starvation.

  8. Optimization of instrumental neutron activation analysis method by means of 2k experimental design technique aiming the validation of analytical procedures

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2013-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2 k experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  9. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  10. Hot-Fire Test Results of Liquid Oxygen/RP-2 Multi-Element Oxidizer-Rich Preburners

    Science.gov (United States)

    Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.; Hulka, J. R.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. To supply the oxidizer-rich combustion products to the main injector of the integrated test article, existing subscale preburner injectors from a previous NASA-funded oxidizer-rich staged combustion engine development program were utilized. For the integrated test article, existing and newly designed and fabricated inter-connecting hot gas duct hardware were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. However, before one of the preburners was used in the integrated test article, it was first hot-fire tested at length to prove it could provide the hot exhaust gas mean temperature, thermal uniformity and combustion stability necessary to perform in the integrated test article experiment. This paper presents results from hot-fire testing of several preburner injectors in a representative combustion chamber with a sonic throat. Hydraulic, combustion performance, exhaust gas thermal uniformity, and combustion stability data are presented. Results from combustion stability modeling of these test results are described in a companion paper at this JANNAF conference, while hot-fire test results of the preburner injector in the integrated test article are described in another companion paper.

  11. Optimization of instrumental neutron activation analysis method by means of 2{sup k} experimental design technique aiming the validation of analytical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Petroni, Robson; Moreira, Edson G., E-mail: rpetroni@ipen.br, E-mail: emoreira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2{sup k} experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  12. Cold neutron prompt gamma activation analysis at NIST; A progress report

    Energy Technology Data Exchange (ETDEWEB)

    Paul, R L; Lindstrom, R M [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Div. of Inorganic Analytical Research; Vincent, D H [Michigan Univ., Ann Arbor, MI (United States). Dept. of Nuclear Engineering

    1994-05-01

    An instrument for prompt gamma-ray activation analysis is now in operation at the NIST Cold Neutron Research Facility (CNRF). The cold neutron beam is relatively free of contamination by fast neutrons and reactor gamma rays, and the neutron fluence rate is 1.5 x 10 [sup 8] cm [sup -2] x s [sup -1] (thermal equivalent). As a result of a compact target-detector geometry the sensitivity is better by a factor of as much as seven than that obtained with an existing thermal instrument, and hydrogen background is a factor of 50 lower. This instrument was applied to multielement analysis of the Allende meteorite and other materials. (author) 14 refs.; 2 figs.; 1 tab.

  13. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  14. Multielement analysis of rice flour-unpolished reference material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1990-01-01

    Trace elements in NIES certified reference material No. 10-a∼10-c Rice Flour-Unpolished, prepared by the National Institute for Environmental Studies of Japan (NIES), were determined by instrumental neutron activation analysis (INAA). A set of three samples with different Cd concentration levels was subjected to analyses. Portions of each sample (ca. 200∼1000 mg) were irradiated, either with thermal neutrons without cadmium filter or with epithermal neutrons with cadmium filter, in the Musashi Institute of Technology Research Reactor (MITRR). The activated samples were analyzed by the three methods; conventional γ-ray spectrometry using a coaxial Ge detector, anticoincidence counting spectrometry, and coincidence counting spectrometry using a coaxial Ge detector and a well type NaI(Tl) detector. Concentrations of 26∼28 elements were determined by these methods. The values obtained for many elements, except for Mg and K, were in good agreement with those of the NIES certified and reference. Concentrations of 10 elements (S, Sc, V, Ag, Sb, Cs, Ba, La, Sm, Th), whose certified or reference values are not available from NIES, were also determined in this work. (author)

  15. Quantitative real-time monitoring of multi-elements in airborne particulates by direct introduction into an inductively coupled plasma mass spectrometer

    International Nuclear Information System (INIS)

    Suzuki, Yoshinari; Sato, Hikaru; Hiyoshi, Katsuhiro; Furuta, Naoki

    2012-01-01

    A new calibration system for real-time determination of trace elements in airborne particulates was developed. Airborne particulates were directly introduced into an inductively coupled plasma mass spectrometer, and the concentrations of 15 trace elements were determined by means of an external calibration method. External standard solutions were nebulized by an ultrasonic nebulizer (USN) coupled with a desolvation system, and the resulting aerosol was introduced into the plasma. The efficiency of sample introduction via the USN was calculated by two methods: (1) the introduction of a Cr standard solution via the USN was compared with introduction of a Cr(CO) 6 standard gas via a standard gas generator and (2) the aerosol generated by the USN was trapped on filters and then analyzed. The Cr introduction efficiencies obtained by the two methods were the same, and the introduction efficiencies of the other elements were equal to the introduction efficiency of Cr. Our results indicated that our calibration method for introduction efficiency worked well for the 15 elements (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Mo, Sn, Sb, Ba, Tl and Pb). The real-time data and the filter-collection data agreed well for elements with low-melting oxides (V, Co, As, Mo, Sb, Tl, and Pb). In contrast, the real-time data were smaller than the filter-collection data for elements with high-melting oxides (Ti, Cr, Mn, Ni, Cu, Zn, Sn, and Ba). This result implies that the oxides of these 8 elements were not completely fused, vaporized, atomized, and ionized in the initial radiation zone of the inductively coupled plasma. However, quantitative real-time monitoring can be realized after correction for the element recoveries which can be calculated from the ratio of real-time data/filter-collection data. - Highlights: ► APs were directly introduced into ICP-MS and real-time analysis was performed. ► The real-time data were calibrated by a multi-element standard solution from USN. ► During real

  16. Multi-element analysis of wheat flour and white bread by neutron activation

    International Nuclear Information System (INIS)

    Godinez A, M.A.

    1994-01-01

    One of the best source of feeding even for the human being as for animals are the Cereals. Although they are mainly energetic aliment, due to its composition in starch, they are a very important source of proteins and amino acids. They contribute mineral elements to the diet. Even those elements constitute a very small part of the total diet, they take a very important place in many human metabolic processes. To make a multielemental analysis of an aliment is very important that we are based on a very sensible analytic technique so we are able to find them, just as the Neutronic Activation. This Nuclear technique allows you to make a qualitative and quantitative analysis of the elements that are in a sample, but it does n't show the way in which the elements are presented. It is based in turning those elements into radioactive ones through its exposition to an uniform and constant fluid of neutrons, so then its radioactivity can be determined. The present work has as a main purpose to make a multielemental analysis of the wheat flour and white bread through the Neutronic Activation Technique, using the comparator method and establishing previously the most appropriate work conditions as much irradiation as digestion and measuring of the radioactivity of the sample. In this way, it was able to know that the wheat flour has potassium, chlorine, magnesium, sodium, iron, zinc, manganese, rubidium and selenium elements in a concentration of 2000, 700, 500, 25, 18, 13, 5.5, 0.9 and 0.01 - 0.3 mg/g respectively. In an other hand it was found that the white bread has the same elements than the wheat flour but its concentration was: 1700, 9000, 400, 7000, 52, 13, 6, 1 and 0.05 - 0.3 mg/g respectively. (Author)

  17. Rayleigh-based, multi-element coral thermometry: A biomineralization approach to developing climate proxies

    Science.gov (United States)

    Gaetani, G.A.; Cohen, A.L.; Wang, Z.; Crusius, John

    2011-01-01

    This study presents a new approach to coral thermometry that deconvolves the influence of water temperature on skeleton composition from that of “vital effects”, and has the potential to provide estimates of growth temperatures that are accurate to within a few tenths of a degree Celsius from both tropical and cold-water corals. Our results provide support for a physico-chemical model of coral biomineralization, and imply that Mg2+ substitutes directly for Ca2+ in biogenic aragonite. Recent studies have identified Rayleigh fractionation as an important influence on the elemental composition of coral skeletons. Daily, seasonal and interannual variations in the amount of aragonite precipitated by corals from each “batch” of calcifying fluid can explain why the temperature dependencies of elemental ratios in coral skeleton differ from those of abiogenic aragonites, and are highly variable among individual corals. On the basis of this new insight into the origin of “vital effects” in coral skeleton, we developed a Rayleigh-based, multi-element approach to coral thermometry. Temperature is resolved from the Rayleigh fractionation signal by combining information from multiple element ratios (e.g., Mg/Ca, Sr/Ca, Ba/Ca) to produce a mathematically over-constrained system of Rayleigh equations. Unlike conventional coral thermometers, this approach does not rely on an initial calibration of coral skeletal composition to an instrumental temperature record. Rather, considering coral skeletogenesis as a biologically mediated, physico-chemical process provides a means to extract temperature information from the skeleton composition using the Rayleigh equation and a set of experimentally determined partition coefficients. Because this approach is based on a quantitative understanding of the mechanism that produces the “vital effect” it should be possible to apply it both across scleractinian species and to corals growing in vastly different environments. Where

  18. [Ultra-Fine Pressed Powder Pellet Sample Preparation XRF Determination of Multi-Elements and Carbon Dioxide in Carbonate].

    Science.gov (United States)

    Li, Xiao-li; An, Shu-qing; Xu, Tie-min; Liu, Yi-bo; Zhang, Li-juan; Zeng, Jiang-ping; Wang, Na

    2015-06-01

    The main analysis error of pressed powder pellet of carbonate comes from particle-size effect and mineral effect. So in the article in order to eliminate the particle-size effect, the ultrafine pressed powder pellet sample preparation is used to the determination of multi-elements and carbon-dioxide in carbonate. To prepare the ultrafine powder the FRITSCH planetary Micro Mill machine and tungsten carbide media is utilized. To conquer the conglomeration during the process of grinding, the wet grinding is preferred. The surface morphology of the pellet is more smooth and neat, the Compton scatter effect is reduced with the decrease in particle size. The intensity of the spectral line is varied with the change of the particle size, generally the intensity of the spectral line is increased with the decrease in the particle size. But when the particle size of more than one component of the material is decreased, the intensity of the spectral line may increase for S, Si, Mg, or decrease for Ca, Al, Ti, K, which depend on the respective mass absorption coefficient . The change of the composition of the phase with milling is also researched. The incident depth of respective element is given from theoretical calculation. When the sample is grounded to the particle size of less than the penetration depth of all the analyte, the effect of the particle size on the intensity of the spectral line is much reduced. In the experiment, when grounded the sample to less than 8 μm(d95), the particle-size effect is much eliminated, with the correction method of theoretical α coefficient and the empirical coefficient, 14 major, minor and trace element in the carbonate can be determined accurately. And the precision of the method is much improved with RSD element, the fluorescence yield is low and the interference is serious. With the manual multi-layer crystal PX4, coarse collimator, empirical correction, X-ray spectrometer can be used to determine the carbon dioxide in the carbonate

  19. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  20. Fast neutron activation analysis and radioisotope X-ray fluorescence study on KALEWA and NAMMA coal

    Energy Technology Data Exchange (ETDEWEB)

    Naing-Win, [Arts and Science University, Yangon (Myanmar)

    1981-07-01

    Kalewa coal was studied with Fast Neutron Activation Analysis (FNAA) technique, employing KAMAN A-710 neutron generator and HP(Ge) detector coupled to ``Canberra`` series 30 MCA. Sequential irradiation and dual aluminium foil monitoring method was employed. Simultaneous multielement analysis was carried out. Namma Coal was studied with radioisotope X-ray Fluorescence (XRF) technique, employing Co-57 exciter source and HP(Ge) detector coupled to ``Canberra`` series 40 MCA. In both FNAA and XRF study, the results obtained were compared to that obtained with Atomic Absorption Spectrophotometry (AAS) technique. Finally, the results were reviewed together with those obtained from similar work on coal with FNAA and XRF techniques. (author).

  1. Fast neutron activation analysis and radioisotope X-ray fluorescence study on KALEWA and NAMMA coal

    International Nuclear Information System (INIS)

    Naing-Win

    1981-07-01

    Kalewa coal was studied with Fast Neutron Activation Analysis (FNAA) technique, employing KAMAN A-710 neutron generator and HP(Ge) detector coupled to ''Canberra'' series 30 MCA. Sequential irradiation and dual aluminium foil monitoring method was employed. Simultaneous multielement analysis was carried out. Namma Coal was studied with radioisotope X-ray Fluorescence (XRF) technique, employing Co-57 exciter source and HP(Ge) detector coupled to ''Canberra'' series 40 MCA. In both FNAA and XRF study, the results obtained were compared to that obtained with Atomic Absorption Spectrophotometry (AAS) technique. Finally, the results were reviewed together with those obtained from similar work on coal with FNAA and XRF techniques. (author)

  2. Possible applications of energy-dispersive powder diffractometry in the phase analysis of metallurgical and geological specimens

    International Nuclear Information System (INIS)

    Koch, S.; Jugelt, P.

    1978-01-01

    Energy-dispersive powder diffractometry renders possible nondestructive quantitative determination of both α and γ phases of iron with shorter measuring time as compared to angle-dispersive techniques. In investigating geological specimens above all the possibility of obtaining qualitative survey analyses within short time is advantageous. The comparatively lower separability leads to difficulties because of increased line density. Therefore, quantitative phase analysis requires the use of spectra unfolding programmes. For laboratory analyses it is advantageous that the same measuring equipment allows the performance of multi-element analyses. (author)

  3. Radiochemical analysis - a survey of its present state

    International Nuclear Information System (INIS)

    Kosta, L.

    1986-01-01

    Recent decline in the utilization of nuclear activation analysis is in part the consequence of diminished interest in nuclear energy and of a parallel decrease in the availability of irradiation facilities. Associated radiation is another important factor making nuclear techniques less popular. Progress in other analytical approaches currently reduces the share of activation analysis in the total output of analytical data. Thermal neutron activation analysis specifically is indispensable in providing multielement analytical data at low concentration levels for most environmental and geological research projects. High technologies involving less common or high-purity materials also need supporting results by this technique which offers high sensitivity and is not affected by blanks. Recent development of powerful computer programs for optimization of analytical parameters and for deconvolution of complex spectra, together with easy adaptation to automated operation, enhance the instrumental capabilities of nuclear activation techniques. (orig.) [de

  4. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

    International Nuclear Information System (INIS)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G.; Prohaska, Thomas

    2007-01-01

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for 35 Cl + to more than 6 x 10 5 cps for 238 U + for 1 μg of trace element per gram of coal sample. Detection limits vary from 450 ng g -1 for chlorine and 18 ng g -1 for sulfur to 9.5 pg g -1 for mercury and 0.3 pg g -1 for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. (orig.)

  5. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Prohaska, Thomas; Heumann, Klaus G

    2007-10-01

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for (35)Cl+ to more than 6 x 10(5) cps for (238)U+ for 1 microg of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.

  6. Optimization of instrumental activation analysis conditions

    International Nuclear Information System (INIS)

    Guinn, V.; Gavrilas-Guinn, M.

    1993-01-01

    In instrumental neutron activation analysis (INAA) work, a good commonsense rule of thumb is that the opium conditions for the measurement of any induced activity, in a multi-element sample matrix, are an irradiation time, a decay time, and a counting time each approximately equal to the half-life of the radionuclide (if feasible). The INAA Advance Computer Program (APCP) was used to test this rule on ten reference materials. For the 280 radionuclide/material combinations traced through all 14 APCP condition sets, the rule predicted the best set for 67% of them, was off by one set for 31% of them, and was only off by two sets of 2% of them. (author) 6 refs.; 1 fig.; 3 tabs

  7. Modelling of the acoustic field of a multi-element HIFU array scattered by human ribs

    Science.gov (United States)

    Gélat, Pierre; ter Haar, Gail; Saffari, Nader

    2011-09-01

    The efficacy of high-intensity focused ultrasound (HIFU) for the treatment of a range of different cancers, including those of the liver, prostate and breast, has been demonstrated. As a non-invasive focused therapy, HIFU offers considerable advantages over techniques such as chemotherapy and surgical resection in terms of reduced risk of harmful side effects. Despite this, there are a number of significant challenges which currently hinder its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the rib cage to induce tissue necrosis in the required volume whilst minimizing the formation of side lobes. Multi-element random-phased arrays are currently showing great promise in overcoming the limitations of single-element transducers. Nevertheless, successful treatment of a patient with liver tumours requires a thorough understanding of the way in which the ultrasonic pressure field from a HIFU array is scattered by the rib cage. In order to address this, a boundary element approach based on a generalized minimal residual (GMRES) implementation of the Burton-Miller formulation was used in conjunction with phase conjugation techniques to focus the field of a 256-element random HIFU array behind human ribs at locations requiring intercostal and transcostal treatment. Simulations were carried out on a 3D mesh of quadratic pressure patches generated using CT scan anatomical data for adult ribs 9-12 on the right side. The methodology was validated on spherical and cylindrical scatterers. Field calculations were also carried out for idealized ribs, consisting of arrays of strip-like scatterers, demonstrating effects of splitting at the focus. This method has the advantage of fully accounting for the effect of scattering and diffraction in 3D under continuous wave excitation.

  8. Modelling of the acoustic field of a multi-element HIFU array scattered by human ribs

    Energy Technology Data Exchange (ETDEWEB)

    Gelat, Pierre [National Physical Laboratory, Hampton Road, Teddington TW11 0LW (United Kingdom); Ter Haar, Gail [Therapeutic Ultrasound Group, Physics Department, Institute of Cancer Research, Sutton SM2 5NG (United Kingdom); Saffari, Nader, E-mail: Pierre.Gelat@npl.co.uk [Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom)

    2011-09-07

    The efficacy of high-intensity focused ultrasound (HIFU) for the treatment of a range of different cancers, including those of the liver, prostate and breast, has been demonstrated. As a non-invasive focused therapy, HIFU offers considerable advantages over techniques such as chemotherapy and surgical resection in terms of reduced risk of harmful side effects. Despite this, there are a number of significant challenges which currently hinder its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the rib cage to induce tissue necrosis in the required volume whilst minimizing the formation of side lobes. Multi-element random-phased arrays are currently showing great promise in overcoming the limitations of single-element transducers. Nevertheless, successful treatment of a patient with liver tumours requires a thorough understanding of the way in which the ultrasonic pressure field from a HIFU array is scattered by the rib cage. In order to address this, a boundary element approach based on a generalized minimal residual (GMRES) implementation of the Burton-Miller formulation was used in conjunction with phase conjugation techniques to focus the field of a 256-element random HIFU array behind human ribs at locations requiring intercostal and transcostal treatment. Simulations were carried out on a 3D mesh of quadratic pressure patches generated using CT scan anatomical data for adult ribs 9-12 on the right side. The methodology was validated on spherical and cylindrical scatterers. Field calculations were also carried out for idealized ribs, consisting of arrays of strip-like scatterers, demonstrating effects of splitting at the focus. This method has the advantage of fully accounting for the effect of scattering and diffraction in 3D under continuous wave excitation.

  9. Applicability of PIXE for multielemental analysis in a biomedical application

    International Nuclear Information System (INIS)

    Shakir, N.S.

    1987-07-01

    The applicability of PIXE for multielemental analysis is demonstrated. The method is used in a major systematic study on hair samples using one target analysis. The pathological state considered is agitated elderly people. The main elements examined are S, K, Ca, Fe, Co, Ni, Cu, Zn, Se, Br, Hg and Pb. The minimum detectable limits are 1-10 ppm using 180 μg of dry hair at 25 μe irradiations for elements between K and Br. The significance of differences between the hair elements in control populations and patients suffering from the pathological conditions are investigated. Investigations of possible linear and multiple-correlations between elements in each population are made. The work indicates that some elements do exhibit variation with pathological state, and the multielement PIXE analysis gives useful information about the subject. (author). 13 refs, 4 figs, 6 tabs

  10. The use of synchrotron radiation for trace element analysis and element mapping by scanning X-ray fluorescence

    International Nuclear Information System (INIS)

    Davies, S.T.

    1983-01-01

    Synchrotron Radiation excited X-Ray Fluorescence is a potentially powerful tool for the routine quantitative chemical analysis of materials, with minimum detection limits typically of the order of a tenth of a ppm, and with the added advantages of simultaneous multi-element detection capability, spatial resolution on a micron scale, large signal to noise ratios and short analysis times. This paper presents a brief review of the use of Synchrotron Radiation in Trace Element Analysis and discusses the requirements for a microprobe for chemical analysis utilising SR. Data obtained at the Synchrotron Radiation Source, Daresbury Laboratory include XRF spectra of standard reference materials and an application of the technique to the study of ion implanted layers in semiconductors is outlined. (author)

  11. MULTI-ELEMENT ABUNDANCE MEASUREMENTS FROM MEDIUM-RESOLUTION SPECTRA. II. CATALOG OF STARS IN MILKY WAY DWARF SATELLITE GALAXIES

    International Nuclear Information System (INIS)

    Kirby, Evan N.; Cohen, Judith G.; Guhathakurta, Puragra; Rockosi, Constance M.; Simon, Joshua D.; Geha, Marla C.; Sneden, Christopher; Sohn, Sangmo Tony; Majewski, Steven R.; Siegel, Michael

    2010-01-01

    We present a catalog of Fe, Mg, Si, Ca, and Ti abundances for 2961 stars in eight dwarf satellite galaxies of the Milky Way (MW): Sculptor, Fornax, Leo I, Sextans, Leo II, Canes Venatici I, Ursa Minor, and Draco. For the purposes of validating our measurements, we also observed 445 red giants in MW globular clusters and 21 field red giants in the MW halo. The measurements are based on Keck/DEIMOS medium-resolution spectroscopy (MRS) combined with spectral synthesis. We estimate uncertainties in [Fe/H] by quantifying the dispersion of [Fe/H] measurements in a sample of stars in monometallic globular clusters (GCs). We estimate uncertainties in Mg, Si, Ca, and Ti abundances by comparing to high-resolution spectroscopic abundances of the same stars. For this purpose, a sample of 132 stars with published high-resolution spectroscopy in GCs, the MW halo field, and dwarf galaxies has been observed with MRS. The standard deviations of the differences in [Fe/H] and ([α/Fe]) (the average of [Mg/Fe], [Si/Fe], [Ca/Fe], and [Ti/Fe]) between the two samples is 0.15 and 0.16, respectively. This catalog represents the largest sample of multi-element abundances in dwarf galaxies to date. The next papers in this series draw conclusions on the chemical evolution, gas dynamics, and star formation histories from the catalog presented here. The wide range of dwarf galaxy luminosity reveals the dependence of dwarf galaxy chemical evolution on galaxy stellar mass.

  12. Multi element analysis by X-ray fluorescence. A powerful tool of ivory identification from various origins

    International Nuclear Information System (INIS)

    Kautenburger, R.; Mueller, P.; Wannemacher, J.

    2004-01-01

    The 11th CITES Conference in 2000 decided to maintain a total worldwide ban on trade of elephant ivory. The 12th Conference in 2002 decided to allow a conditional trade in stockpiled ivory in 2004. Reopening of the ivory trade would require methods to identify the origin of the ivory so that legal ivory can be distinguished from the black-market ones. X-ray fluorescence multi-element analysis of ivory samples from various regions of Africa and Southeast-Asia to characterize ivory of the various elephant populations is described. (author)

  13. Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1977-01-01

    Two important aspects of the analytical performance of a newly developed ultrasonic nebulizer and a specially designed pneumatic nebulizer have been compared for use in inductively coupled plasma--atomic emission spectroscopy (ICP-AES). The ultrasonic nebulizer, when combined with a conventional aerosol desolvation apparatus, provided an order of magnitude or more improvement in simultaneous multielement detection limits as compared to those obtained when the pneumatic nebulizer was used either with or without desolvation. Application of a novel method for direct measurement of the overall efficiency of nebulization to the two systems showed that an approximately tenfold greater rate of sample delivery to the plasma torch was primarily responsible for the superior detection limits afforded by the ultrasonic nebulizer. A unique feature of the ultrasonic nebulizer described is the protection against chemical attack which is achieved by completely enclosing the transducer in an acoustically coupled borosilicate glass cylinder. Direct sample introduction, convenient sample change, and rapid cleanout are other important characteristics of the system which make it an attractive alternate to pneumatic nebulizer systems

  14. Trace analysis measurements in high-purity aluminium by means of radiochemical neutron and proton activation analysis

    International Nuclear Information System (INIS)

    Egger, K.P.

    1987-01-01

    The aim of the study consisted in the development of efficient radiochemical composite processes and activation methods for the multi-element determination of traces within the lower ng range in high-purity aluminium. More than 50 elements were determined with the help of activation with reactor neutrons; the selective separation of matrix activity (adsorption with hydrated antimony pentoxide) led to a noticeable improvement of detectability, as compared with instrumental neutron activation analysis. Further improvements were achieved with the help of radiochemical group separations in ion exchangers or with the help of the selective separation of the pure beta-emitting elements. Over 20 elements up to high atomic numbers were determined by means of activating 13 MeV protons and 23 Me protons. In this connection, improvements of the detection limit by as a factor of 10 were achieved with radiochemical separation techniques, as compared with pure instrumental proton activation analysis. (RB) [de

  15. Physical aspects of quantitative particles analysis by X-ray fluorescence and electron microprobe techniques

    International Nuclear Information System (INIS)

    Markowicz, A.

    1986-01-01

    The aim of this work is to present both physical fundamentals and recent advances in quantitative particles analysis by X-ray fluorescence (XRF) and electron microprobe (EPXMA) techniques. A method of correction for the particle-size effect in XRF analysis is described and theoretically evaluated. New atomic number- and absorption correction procedures in EPXMA of individual particles are proposed. The applicability of these two correction methods is evaluated for a wide range of elemental composition, X-ray energy and sample thickness. Also, a theoretical model for composition and thickness dependence of Bremsstrahlung background generated in multielement bulk specimens as well as thin films and particles are presented and experimantally evaluated. Finally, the limitations and further possible improvements in quantitative particles analysis by XFR and EPXMA are discussed. 109 refs. (author)

  16. Extended automated separation techniques in destructive neutron activation analysis; application to various biological materials, including human tissues and blood

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Houtman, J.P.W.

    1976-09-01

    Neutron activation analysis may be performed as a multi-element and low-level technique for many important trace elements in biological materials, provided that post-irradiation chemical separations are applied. This paper describes a chemical separation consisting of automated procedures for destruction, distillation, and anion-chromatography. The system developed enables the determination of 14 trace elements in biological materials, viz. antimony, arsenic, bromine, cadmium, chromium, cobalt, copper, gold, iron, mercury, molybdenum, nickel, selenium, and zinc. The aspects of sample preparation, neutron irradiation, gamma-spectrum evaluation, and blank-value contribution are also discussed

  17. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  18. A comparative study of neutron activation analysis and proton-induced X-ray emission analysis for the determination of heavy metals in estuarine sediments

    Science.gov (United States)

    Randle, K.; Al-Jundi, J.; Mamas, C. J. V.; Sokhi, R. S.; Earwaker, L. G.

    1993-06-01

    Our work on heavy metals in the estuarine environment has involved the use of two multielement techniques: neutron activation analysis (NAA) and proton-induced X-ray emission (PIXE) analysis. As PIXE is essentially a surface analytical technique problems may arise due to sample inhomogeneity and surface roughness. In order to assess the contribution of these effects we have compared the results from PIXE analysis with those from a technique which analyzes a larger bulk sample rather than just the surface. An obvious method was NAA. A series of sediment samples containing particles of variable diameter were compared. Pellets containing a few mg of sediment were prepared from each sample and analyzed by the PIXE technique using both an absolute and a comparitive method. For INAA the rest of the sample was then irradiated with thermal neutrons and element concentrations determined from analyses of the subsequent gamma-ray spectrum. Results from the two methods are discussed.

  19. Neutron activation analysis is 60 years old: Is it time for retirement?

    International Nuclear Information System (INIS)

    de Goeij, J.J.M.

    1996-01-01

    In the past 60 yr, NAA (neutron activation analysis) has become an outstanding analytical technique for quite a few elements. In earlier days, radiochemical NAA (RNAA) with postirradiation radiochemical separations was the dominant version. In the last 25 yr, after introduction of high-resolution germanium semiconductor detectors in combination with sophisticated electronics and software, instrumental NAA (INAA) became the predominant version. The characteristic features of NAA are (a) multielement capability; (b) generally good selectivity; (c) low determination limits for quite a few elements; (d) no effect of the chemical state of the analyte; (e) relatively small matrix effects; (f) absence or minimization of the blank value; (g) simple calibration; (h) analysis of samples up to kilograms, physically independent method compared to other trace-element techniques; and (h) easily definable sources of systematic or random errors

  20. Multielement determination of major-to-ultratrace elements in plant reference materials by ICP-AES/ICP-MS and evaluation of their enrichment factors

    International Nuclear Information System (INIS)

    Hokura, Akiko; Matsuura, Hirotaka; Katsuki, Fumie; Haraguchi, Hiroki

    2000-01-01

    The multielement determination of major-to-ultratrace elements in plant reference materials (SRM Pine Needles, SRM Tomato Leaves, and NIES Tea Leaves) was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). The plant sample was decomposed with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The digest was dissolved in 1 M HNO 3 solution, and then subjected to elemental analyses. As a consequence, the analytical data for about 40 elements including rare earth elements (REEs) were obtained over a wide concentration range, for example, from 49600 μg g -1 of Ca to 6.2 ng g -1 of Lu in Tomato Leaves. The enrichment factors, which were estimated by normalizing the observed concentrations of analyte elements in plant reference materials to their soil abundances, were evaluated in order to discuss the relative abundances of various elements between plants and soil. It was found that most of the elements, except for REEs in Pine Needles and Tea Leaves, were significantly accumulated in the plant reference materials. In particular, the essential elements (K, Mg, Ca, Mn, Cu, Zn, B and P) for plant growth provided large enrichment factors. (author)

  1. [Principal component analysis and cluster analysis of inorganic elements in sea cucumber Apostichopus japonicus].

    Science.gov (United States)

    Liu, Xiao-Fang; Xue, Chang-Hu; Wang, Yu-Ming; Li, Zhao-Jie; Xue, Yong; Xu, Jie

    2011-11-01

    The present study is to investigate the feasibility of multi-elements analysis in determination of the geographical origin of sea cucumber Apostichopus japonicus, and to make choice of the effective tracers in sea cucumber Apostichopus japonicus geographical origin assessment. The content of the elements such as Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Hg and Pb in sea cucumber Apostichopus japonicus samples from seven places of geographical origin were determined by means of ICP-MS. The results were used for the development of elements database. Cluster analysis(CA) and principal component analysis (PCA) were applied to differentiate the sea cucumber Apostichopus japonicus geographical origin. Three principal components which accounted for over 89% of the total variance were extracted from the standardized data. The results of Q-type cluster analysis showed that the 26 samples could be clustered reasonably into five groups, the classification results were significantly associated with the marine distribution of the sea cucumber Apostichopus japonicus samples. The CA and PCA were the effective methods for elements analysis of sea cucumber Apostichopus japonicus samples. The content of the mineral elements in sea cucumber Apostichopus japonicus samples was good chemical descriptors for differentiating their geographical origins.

  2. Multielement analysis by neutron activation of tissues from swine administered copper supplemented diets

    International Nuclear Information System (INIS)

    Stroube, W.B. Jr.; Cunningham, W.C.; Tanner, J.T.; Bradley, B.D.; Graber, G.

    1982-01-01

    Instrumental neutron activation analysis was used to determine Co, Cu, Fe, Mg, Mn, Se and Zn in tissues from swine fed copper supplemented diets. Elemental abundances of the seven elements in the kidney tissues are all within normal ranges. No trends are observed between the groups of animals which received different levels of dietary copper. Dietary copper values of 70 to 90 ppm increase liver copper abundance for certain animals. (author)

  3. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F. [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria); Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Prohaska, Thomas [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria)

    2007-10-15

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for {sup 35}Cl{sup +} to more than 6 x 10{sup 5} cps for {sup 238}U{sup +} for 1 {mu}g of trace element per gram of coal sample. Detection limits vary from 450 ng g{sup -1} for chlorine and 18 ng g{sup -1} for sulfur to 9.5 pg g{sup -1} for mercury and 0.3 pg g{sup -1} for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. (orig.)

  4. Analysis of coal by neutron activation

    International Nuclear Information System (INIS)

    Burtner, D.R.

    1983-01-01

    The development of a thermal-neutron activation analysis procedure for determining elemental concentrations in whole coal samples, and the goal of combining this technique with other nuclear methods for determining a total mass balance in these and similar complex materials, is described. Problems of applying a fast-neutron activation analysis method for nitrogen are discussed, as well as an efficient procedure for drying and packaging coal samples. A thermal-neutron activation analysis (TNAA) procedure was developed for determining up to 27 elements in coal samples from the US, China, Nigeria, and Brazil. The comparator form of TNAA was applied, using a unique multielement standard, which contained 48 elements. The difference in net photopeak counts between sample and standard, due to γ-ray attenuation, was reduced by preparing this standard in an organic matrix, which simulates the composition and physical structure of the coal material. The simultaneous irradiation of several aliquots of this standard enabled high precision and accuracy to be attained. An accurate value for oxygen, determined by fast-neutron activation analysis, is used to correct for this effect in the nitrogen determination method

  5. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Anjos, M.J.; Lopes, R.T.; Jesus, E.F.O. de; Moreira, S.; Barroso, R.C.; Castro, C.R.F.

    2003-01-01

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  6. Evaluation of multielement in serum of healthy population of the metropolitan area of the state of Rio de Janeiro by TXRF

    International Nuclear Information System (INIS)

    Canellas, Catarine G.L.; Anjos, Marcelino J.; Leitao, Roberta G.; Lopes, Ricardo Tadeu; Bellido, Alfredo Victor B.

    2013-01-01

    The determination of multielemental concentrations in physiological fluids is of considerable interest in clinical chemistry. Since it has been established this levels in human serum can be utilized as indicators for several pathological conditions. The multielement composition determination in human serum is important for the investigation of their role in human physiology and metabolism. From this research, more detailed studies on the health of individuals living in the metropolitan region of the state of Rio de Janeiro can be realized in order to improve the quality of life of these individuals. We studied three hundred and sixty healthy volunteers (162 males and 198 females) aged 18 to 60 years old. All the serum samples had been collected of people who live in the urban area of Rio de Janeiro City/Brazil. The measurements were performed at the X-Ray Fluorescence Beamline at the Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a monochromatic beam with maximum energy of 20 keV for the excitation and an Ultra-LEGe detector with resolution of 148 eV at 5.9 keV. Standards solutions with Vanadium and Galium (Internal standards) were prepared for the calibration system. It was possible to determine the elemental concentrations of the following eleven elements: Na, P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. (author)

  7. Evaluation of multielement in serum of healthy population of the metropolitan area of the state of Rio de Janeiro by TXRF

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Anjos, Marcelino J., E-mail: c.canellas@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.br [Instituto Estadual de Hematologia Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Leitao, Roberta G.; Lopes, Ricardo Tadeu, E-mail: roberta@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear; Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.br [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Quimica

    2013-07-01

    The determination of multielemental concentrations in physiological fluids is of considerable interest in clinical chemistry. Since it has been established this levels in human serum can be utilized as indicators for several pathological conditions. The multielement composition determination in human serum is important for the investigation of their role in human physiology and metabolism. From this research, more detailed studies on the health of individuals living in the metropolitan region of the state of Rio de Janeiro can be realized in order to improve the quality of life of these individuals. We studied three hundred and sixty healthy volunteers (162 males and 198 females) aged 18 to 60 years old. All the serum samples had been collected of people who live in the urban area of Rio de Janeiro City/Brazil. The measurements were performed at the X-Ray Fluorescence Beamline at the Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a monochromatic beam with maximum energy of 20 keV for the excitation and an Ultra-LEGe detector with resolution of 148 eV at 5.9 keV. Standards solutions with Vanadium and Galium (Internal standards) were prepared for the calibration system. It was possible to determine the elemental concentrations of the following eleven elements: Na, P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. (author)

  8. Synthetic multielement standards used for instrumental neutron activation analysis as rock imitations

    International Nuclear Information System (INIS)

    Leypunskaya, D.I.; Drynkin, V.I.; Belenky, B.V.; Kolomijtsev, M.A.; Dundera, V.Yu.; Pachulia, N.V.

    1975-01-01

    Complex (multielemental) standards representing microelement composition of standard rocks such as trap ST-1 (USSR), gabbrodiorite SGD-1 (USSR), albitized granite SG-1 (USSR), basalt BCR-1 (USA) and granodiorite GSP-1 (USA) have been synthesized. It has been shown that the concentration of each microelement in the synthetic standards can be given with a high precision. Comparative investigation has been carried out of the synthetic imitations and the above natural standard rocks. It has been found that the result of the instrumental neutron activation analysis using the synthetic standards is as good as in the case when natural standard rocks are used. The results obtained have been also used for substantiation of the versatility of the method used for standard preparation, i.e. a generalization has been made of a possibility of using this method for the preparation of synthetic standards representing the microelement composition of any natural rocks with various compositions and concentrations of microelements. (T.G.)

  9. Computer analysis to the geochemical of soil and stream sediments data in an area of Southern Uruguay

    International Nuclear Information System (INIS)

    Spangenberg, J.

    2012-01-01

    This work is about geochemical interpretation of multi-element data from a soil and stream sediment survey carried out in Southern of Uruguay .This zone has several occurrences of metal sulphide mineralization

  10. Neutron activation analysis of monomineral fractions

    International Nuclear Information System (INIS)

    Drykhin, V.I.; Belen'kij, B.V.; Voinkov, D.M.; Il'yasova, K.I.; Lejpinskaya, D.I.; Nedostyp, T.V.

    1977-01-01

    The results are described of the development of an instrumental neutron activation analysis (INAA) of monomineral sulfides (pyrites, pyrrhotites, chalcopyrites and others), quartzites and other minerals, the technique being intended for geochemical investigations. For a multi-element INAA of monomineral sulfides, the optimum irradiation time in a flux of 10 12 to 1.3x10 13 n/cm 2 (neutron field of a nuclear reactor) is 20 to 40 hours, thus ensuring a reliable determination of a great number of elements not lower than 10 -4 %. The time of the induced activity for determining indium in sulfides is 0.5 to 3 min. The actual sensitivity of the method is 10 -4 %. A sensitivity with respect to gold of 0.01 g/t was attained in monominerals after an irradiation of up to 5 min

  11. ''Top-down'' versus ''side-on'' viewing of the inductively coupled plasma

    International Nuclear Information System (INIS)

    Faires, L.M.; Bieniewski, T.M.; Apel, C.T.; Niemczyk, T.M.

    1985-01-01

    The inductively coupled plasma is viewed by a ''top-down'' optical configuration, and the analytical performance is compared to conventional ''side-on'' viewing in terms of sensitivity, detection limits, linear dynamical range, self-reversal effects, and multielement performance. This comparison is made for a selection of eleven atom and ion lines of eight elements. The results of this study indicate distinct advantages in ''top-down'' viewing including improved sensitivity, lower detection limits, better signal-to-background ratios, and better compromise viewing position for multielement analysis. An exception to these advantages is increased self-absorption effects observed for the alkali elements

  12. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Fischer, E.

    1976-05-01

    A neutron activation method for multielement determination in biological material was developed. The individual steps of the method include radiochemical processing as well as nondestructive techniques. In order to develop a high resolution gamma spectrometric method the indispensable assumptions were the application of Ge(Li)-semiconductor detectors, multi-channel pulse height analyzers and the use of electronic data evaluation with mini-computers for the automatic evaluation of complex gamma spectra. After radiochemical separation (RNAA) 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements is 4 days. The neutron activation method is used routinely for the determination of trace elements in foodstuffs and in the field of nutrition research. (orig.) [de

  13. PIXE analysis of western han dynasty ancient glasses unearthed in Yangzhou city

    International Nuclear Information System (INIS)

    Li Qinghui; Gu Donghong; Gan Fuxi; Zhang Bin; Ma Bo; Cheng Huansheng

    2003-01-01

    Chemical composition analysis is one of the most important research aspects to provide scientific proof for the technical origin and development of Chinese ancient glass. Proton induced X-ray emission (PIXE) technique is a kind of multi-element quantitative analysis method with high sensitivity and without destruction of samples. Chemical composition of the Western Han dynasty glass garment flakes, which were excavated from Yangzhou city, was analyzed by PIXE, quantitatively. It was found that these glass flakes were attributed to PbO-BaO-SiO 2 glass originated in China. These flakes all consist of a glass core and a corroded outer layer with different thickness. There are relatively higher PbO, P 2 O 5 and CaO, while much lower BaO and SiO 2 in the corroded layers than in the glass cores. The experimental results were discussed

  14. Determination of trace elements in cigarette and tobacco by neutron activation analysis

    International Nuclear Information System (INIS)

    Nouchpramool, S.

    1988-01-01

    The objective of this work is to determine the concentration of 22 trace elements in cigarette and tobacco by instrumental neutron activation analysis in which multielements can be analyzed simultaneously with high sensitivity and reliability as well as easy and rapid. It is well known that, trace toxic elements with high concentration may be harmful for health of smokers. Since they might damage the respiratory system and might cause other diseases. The finding for this report can be used as the basis of further study on toxic of trace elements to the smoker. The results of this analysis show that the bromine content in all samples is significantly high, but the concentration of the other elements are varying from one to another. Bromine concentration might come from soil and/or smoked tobacco leaves with methyl bromide as fungicide

  15. Application of X-ray spectroscopy in nondestructive photon activation analysis

    International Nuclear Information System (INIS)

    Weise, H.-P.; Segebade, Chr.

    1977-01-01

    The use of X-ray spectroscopy for the qualitative and quantitative analysis of samples activated by 30 MeV bremsstrahlung from an electron linear accelerator. Detection limits are calculated from the measured X-ray spectra and compared with those for γ-ray spectroscopy. In general, the detection limits for γ-ray and X-ray spectroscopy are comparable. Higher sensitivities for X-ray spectroscopy are observed when only low intensity γ-rays are emitted by the activation products. X-ray spectroscopy should be applied in three cases: (a) low γ-ray emission probability, (b) extremely complicated γ-ray spectrum, (c) overlapping of γ-ray lines from different elements. γ-ray spectroscopy should be preferred for the analysis of light elements for two reasons: very strong absorption of low energy X-rays (low Z) within the sample, low X-ray emission probability for the activation products of light elements. Therefore no attempt was made to use X-ray spectroscopy for the analysis of elements below Ti. Some practical applications of X-ray spectroscopy in nondestructive multielement analysis are quoted. (T.G.)

  16. Neutron activation spectrometry and neutron activation analysis in analytical geochemistry

    International Nuclear Information System (INIS)

    Dulski, P.; Moeller, P.

    1975-07-01

    The present report is to show the geochemists who are interested in neutron activation spectrometry (NAS) and neutron activation analysis (NAA) which analytical possibilities these methods offer him. As a review of these analytical possibilities, a lieterature compolation is given which is subdivided into two groups: 1) rock (basic, intermediary, acid, sediments, soils and nuds, diverse minerals, tectites, meteorites and lunar material). 2) ore (Al, Au, Be, Cr, Cu, Mn, Mo, Fe, Pb, Pt, Sn, Ti, W, Zn, Zr, U and phosphate ore, polymetallic ores, fluorite, monazite and diverse ores). The applied methods as well as the determinable elements in the given materials can be got from the tables. On the whole, the literature evaluation carried out makes it clear that neutron activation spectrometry is a very useful multi-element method for the analysis of rocks. The analysis of ores, however, is subjected to great limitations. As rock analysis is very frequently of importance in prospecting for ore deposits, the NAS proves to be extremely useful for this very field of application. (orig./LH) [de

  17. Position-specific isotope modeling of organic micropollutants transformations through different reaction pathways

    Science.gov (United States)

    Jin, Biao; Rolle, Massimo

    2016-04-01

    Organic compounds are produced in vast quantities for industrial and agricultural use, as well as for human and animal healthcare [1]. These chemicals and their metabolites are frequently detected at trace levels in fresh water environments where they undergo degradation via different reaction pathways. Compound specific stable isotope analysis (CSIA) is a valuable tool to identify such degradation pathways in different environmental systems. Recent advances in analytical techniques have promoted the fast development and implementation of multi-element CSIA. However, quantitative frameworks to evaluate multi-element stable isotope data and incorporating mechanistic information on the degradation processes [2,3] are still lacking. In this study we propose a mechanism-based modeling approach to simultaneously evaluate concentration as well as bulk and position-specific multi-element isotope evolution during the transformation of organic micropollutants. The model explicitly simulates position-specific isotopologues for those atoms that experience isotope effects and, thereby, provides a mechanistic description of isotope fractionation occurring at different molecular positions. We validate the proposed approach with the concentration and multi-element isotope data of three selected organic micropollutants: dichlorobenzamide (BAM), isoproturon (IPU) and diclofenac (DCF). The model precisely captures the dual element isotope trends characteristic of different reaction pathways and their range of variation consistent with observed multi-element (C, N) bulk isotope fractionation. The proposed approach can also be used as a tool to explore transformation pathways in scenarios for which position-specific isotope data are not yet available. [1] Schwarzenbach, R.P., Egli, T., Hofstetter, T.B., von Gunten, U., Wehrli, B., 2010. Global Water Pollution and Human Health. Annu. Rev. Environ. Resour. doi:10.1146/annurev-environ-100809-125342. [2] Jin, B., Haderlein, S.B., Rolle, M

  18. Study on atmosphere pollution by PIXE analysis combining with statistical method

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1994-06-01

    Atmospheric aerosol samples were collected using an 8-stage cascade impactor or an automatic time sequence step sampler at Jomo Langma, Zhangye at the edge of Gobi Desert and Beijing. Element concentration were analyzed by PIXE (proton induced X-ray emission) technique. The data were analyzed by APCA (absolute principal component analysis) to determine the principal components. The sources and contribution to the aerosol in the above three regions were discussed. The result shows that the PIXE has high sensitivity, multi-element capability, high speed and non-destruction advantages. APCA analytical method can effectively determine the aerosol components in urban area, and it also can distinguish between local components and remote components in the area far from the pollution resources

  19. Analysis of oil shale and oil shale products for certain minor elements

    International Nuclear Information System (INIS)

    Dickman, P.T.; Purdy, M.; Doerges, J.E.; Ryan, V.A.; Poulson, R.E.

    1977-01-01

    The University of Wyoming was contracted by the Department of Energy's Laramie Energy Research Center (LERC) to develop rapid, inexpensive, and simple methods of quantitative and qualitative elemental analysis for products used and generated in the simulated in-situ retorting of oil shale. Alpha particle spectrometry was used to determine the radioisotope content of the aqueous retort products. Alpha particles are mono-energetic and the spectrometry method employed had very low background levels (1 count per 2000 seconds). These factors allow for both the quantitative and qualitative analysis of natural radioisotopes at the 1 ppm level. Sample preparation does not require any chemical treatment. Energy dispersive x-ray fluorescence (XRF) was used for the multi-element analysis of the retort products. The XRF, integrated with a mini-computer, allows rapid analysis of several elements in multiple samples. XRF samples require minimal amounts of preparation and analytical results are highly reproducible. This paper presents the methods developed and preliminary analytical results from oil shale by-products. Results from the analysis of oil shale rocks are not yet ready for presentation

  20. Neutron activation analysis with k0-standardisation : general formalism and procedure

    International Nuclear Information System (INIS)

    Pomme, S.; Hardeman, F.; Robouch, P.; Etxebarria, N.; Arana, G.

    1997-09-01

    Instrumental neutron activation analysis (INAA) with k 0 -standardisation is a powerful tool for multi-element analysis at a broad range of trace element concentrations. An overview is given of the basic principles, fundamental equations, and general procedure of this method. Different aspects of the description of the neutron activation reaction rate are discussed, applying the Hogdahl convention. A general activation-decay formula is derived and its application to INAA is demonstrated. Relevant k 0 -definitions for different activation decay schemes are summarised and upgraded to cases of extremely high fluxes. The main standardisation techniques for INAA are discussed, emphasizing the k 0 -standardisation. Some general aspects of the basic equipment and its calibration are discussed, such as the characterisation of the neutron field and the tuning of the spectrometry part. A method for the prediction and optimisation of the analytical performance of INAA is presented

  1. Energy-Dispersive X-Ray Fluorescence Spectrometry: A Long Overdue Addition to the Chemistry Curriculum

    Science.gov (United States)

    Palmer, Peter T.

    2011-01-01

    Portable Energy-Dispersive X-Ray Fluorescence (XRF) analyzers have undergone significant improvements over the past decade. Salient advantages of XRF for elemental analysis include minimal sample preparation, multielement analysis capabilities, detection limits in the low parts per million (ppm) range, and analysis times on the order of 1 min.…

  2. Analysis of fourth-grade flat machines with movable close-cycle formed by the rods and two complex links

    Directory of Open Access Journals (Sweden)

    S.О. Koshel

    2016-09-01

    Full Text Available Complex multielement mechanisms are increasingly used in the technical equipment of consumer industry. The lack of a universal method of kinematic research of these mechanisms asserts the relevance of work on the kinematic analysis of multielement mechanisms. Aim: The aim of this research is to develop an algorithm kinetic research of velocities of the points that coincide with geometric centers kinematic pairs of structure group of the 4th class and 3rd order with movable close-cycle formed by connecting rod and two complex links. Materials and Methods: The graphic-analytical method of a kinematic research will be used to achieve the goals of research. Development of an algorithm is based on provisions of the theory of mechanisms and engines about property of high classes mechanisms to change its class depending on another possible initial mechanism chosen conditionally which comes to structure of the conducted structural groups of the mechanism links and provisions of theoretical mechanics relatively to instantaneous center of speeds. Results: Velocity vectors of points of Assur group links of the 4th class and 3rd order of the composite flat mechanism are determined by a graphic-analytical method, where the initial mechanism speeds that led to decrease of a class of the mechanism and allowed to investigate it. Unlike the known erroneous statements method which is applied to research the structural groups of the 3rd class, the offered algorithm of the kinematic analysis allows to investigate mechanisms of the 4th class without need to rebuild the plan which was constructed in a uncertain scale, with the subsequent calculation of the real scale parameter of provided plotting of a graph.

  3. Aspects of cleaning environmental materials for multi-element analysis, e.g. plant samples

    International Nuclear Information System (INIS)

    Markert, B.

    1992-01-01

    Cleaning of samples is often the first step in the entire procedure of sample preparation in environmental trace element research. The question must generally be raised of whether cleaning is meaningful before chemical investigations with plant material (e.g. for the determination of transfer factors in the soil/plant system) or not (e.g. for food chain analysis in the plant/animal system). The most varied cleaning procedures for plant samples are currently available ranging from dry and wet wiping of the leaf or needle surface up to the complete removal of the cuticule with the aid of chlorofom. There is at present no standardized cleaning procedure for plant samples so that it is frequently not possible to compare analytical data from different working groups studying the same plant species. (orig.)

  4. Biomonitoring in rivers by total-reflection x-ray fluorescence analysis in macrozoobenthos samples

    International Nuclear Information System (INIS)

    Miesbauer, H.; Koeck, G.; Fuereder, L.

    2000-01-01

    A widespread set of analytical methods is used to control the fate of toxic metals in aquatic ecosystems. However, monitoring of water and sediments by metal analysis is not sufficient because of fluctuating metal concentrations in the water and delayed responses of sediments. It also provides little information about metal bioavailability in aquatic ecosystems. Therefore, aquatic organisms are increasingly used for biomonitoring the actual metal load of aquatic biota. Aquatic insects, in particular, satisfy some important criteria established for bioindicators, thus being valuable biomonitoring organisms of metal contamination in freshwater ecosystems. The presented paper describes the investigation of the metal contents of several benthic insect species (e.g. caddisfly larvae) from an Austrian river by using TXRF. Due to it's high sensitivity TXRF allows multi-element analysis of very low metal concentrations even in single individuals of aquatic insect larvae. Our results confirm TXRF to be valuable tool in environmental analysis. (author)

  5. Biomonitoring in rivers by total-reflection x-ray fluorescence analysis in macrozoobenthos samples

    International Nuclear Information System (INIS)

    Miesbauer, H.; Koeck, G.; Fuereder, L.

    2000-01-01

    A widespread set of analytical methods is used to control the fate of toxic metals in aquatic ecosystems. However, monitoring of water and sediments by metal analysis is not sufficient because of fluctuating metal concentrations in the water and delayed responses of sediments. It also provides little information about metal bio-availability in aquatic ecosystems. Therefore, aquatic organisms are increasingly used for bio-monitoring the actual metal load of aquatic biota. Aquatic insects, in particular, satisfy some important criteria established for bio-indicators, thus being valuable bio-monitoring organisms of metal contamination in freshwater ecosystems. The presented paper describes the investigation of the metal contents of several benthic insect species (e.g. caddisfly larvae) from an Austrian river by using TXRF. Due to it's high sensitivity TXRF allows multi-element analysis of very low metal concentrations even in single individuals of aquatic insect larvae. Our results confirm TXRF to be valuable tool in environmental analysis. (author)

  6. Analysis of marine samples by neutron-induced prompt gamma-ray technique and ICP-MS

    International Nuclear Information System (INIS)

    Yonezawa, C.; Matsue, H.; McKay, K.; Povinec, P.

    2001-01-01

    Multi-element and isotopic analyses of oils and marine environmental samples were carried out to estimate a contamination source using a 'finger printing' method. Elemental analyses were carried out using neutron-induced prompt gamma-ray analysis (PGA), instrumental neutron activation analysis (INAA) at the Japan Atomic Institute, Tokai-mura, Japan (JAERI) and ICP-MS in the IAEA Marine Environment Laboratory, Monaco (MEL). Fifteen elements including light elements, H, B, N, Si and Ca, which cannot be determined by INAA and ICP-MS, were determined by PGA. A total of 47 elements were determined in the present study. The potential of PGA for the determination of isotopic ratios was tested by measuring 34 S/ 32 S ratios in oils. The evaluation of historical records of marine environmental conditions using annual bands in coral samples was also investigated. (author)

  7. Obisdian sourcing by PIXE analysis at AURA2

    International Nuclear Information System (INIS)

    Neve, S.R.; Barker, P.H.; Holroyd, S.; Sheppard, P.J.

    1994-01-01

    The technique of Proton Induced X-ray Emission is a suitable method for the elemental analysis of obsidian samples and artefacts. By comparing the elemental composition of obsidian artefacts with those of known sources of obsidian and identifying similarities, the likely origin of the sample can be discovered and information about resource procurement gained. A PIXE facility has now been established at the Auckland University Research Accelerator Laboratory, AURA2. It offers a rapid, multi-element, non-destructive method of characterisation of obsidian samples ranging from small chips to large pieces. In an extensive survey of Mayor Island obsidian, a discrimination has been made between the different locations of obsidian deposits on the island. In addition, using the database developed at AURA2, artefacts from the site of Opita, Hauraki Plains, have been sourced. (Author). 18 refs., 8 figs., 7 tabs., 1 appendix

  8. Current applications of semiconductor x-ray detectors in chemical analysis

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1975-07-01

    In the last few years, semiconductor detectors have been used as X-ray detectors with great success, and the routine rapid accumulation of X-ray spectra is now possible. This review surveys the historical development of the detectors, the utilisation, and relative merits of various means of exciting the X-radiation from the elements in the sample, and compares the technique with other methods claiming to offer the capability of simultaneous multi-element analysis. It is concluded that it is of average sensitivity, but offers some advantages from its non-destructive nature, and in some cases its ability to offer information about the spatial distribution of elements in a sample. Other types of analysis may also be possible simultaneously. Sample preparation techniques are reviewed, especially techniques of manufacturing thin samples. An appendix contains details of the very wide variety of samples which have been analysed. More than 350 references are included. (auth.)

  9. Application of photon activation analysis to the determination of the distribution of toxic elements in soil of a sewage farm

    International Nuclear Information System (INIS)

    Segebade, C.; Schmitt, B.F.; Fusban, H.U.; Kuehl, M.

    1984-01-01

    Bore-cores, taken from waste water charged and closely neighbouring virgin soil regions within the sewage farm in Berlin-Karolinenhoehe were investigated. The distributions of numerous elements along the bore-core length (or soil depth, respectively) were analysed with particular emphasis laid upon toxic components. As many as 27 elements were analysed. By comparison of the concentration profiles the significant partition of anthropogenic pollutants becomes obvious. Instrumental photon activation analysis using an electron accelerator - being a multielement technique - has proven to be a suitable tool for the given analytical task. With this method, elements can be analysed which are not or not readily determinable with other comparable instrumental techniques (thermal neutron activation analysis in particular), e.g. Ni, Tl and Pb. (orig.) [de

  10. Neutron activation analysis with k{sub 0}-standardisation : general formalism and procedure

    Energy Technology Data Exchange (ETDEWEB)

    Pomme, S.; Hardeman, F. [Centre de l`Etude de l`Energie Nucleaire, Mol (Belgium); Robouch, P.; Etxebarria, N.; Arana, G. [European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Geel (Belgium)

    1997-09-01

    Instrumental neutron activation analysis (INAA) with k{sub 0}-standardisation is a powerful tool for multi-element analysis at a broad range of trace element concentrations. An overview is given of the basic principles, fundamental equations, and general procedure of this method. Different aspects of the description of the neutron activation reaction rate are discussed, applying the Hogdahl convention. A general activation-decay formula is derived and its application to INAA is demonstrated. Relevant k{sub 0}-definitions for different activation decay schemes are summarised and upgraded to cases of extremely high fluxes. The main standardisation techniques for INAA are discussed, emphasizing the k{sub 0}-standardisation. Some general aspects of the basic equipment and its calibration are discussed, such as the characterisation of the neutron field and the tuning of the spectrometry part. A method for the prediction and optimisation of the analytical performance of INAA is presented.

  11. Hot-Fire Test Results of an Oxygen/RP-2 Multi-Element Oxidizer-Rich Staged-Combustion Integrated Test Article

    Science.gov (United States)

    Hulka, J. R.; Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. For the thrust chamber assembly of the test article, several configurations of new main injectors, using relatively conventional gas-centered swirl coaxial injector elements, were designed and fabricated. The design and fabrication of these main injectors are described in a companion paper at this JANNAF meeting. New ablative combustion chambers were fabricated based on hardware previously used at NASA for testing at similar size and pressure. An existing oxygen/RP-1 oxidizer-rich subscale preburner injector from a previous NASA-funded program, along with existing and new inter-connecting hot gas duct hardware, were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. Results from independent hot-fire tests of the preburner injector in a combustion chamber with a sonic throat are described in companion papers at this JANNAF conference. The resulting integrated test article - which includes the preburner, inter-connecting hot gas duct, main injector, and ablative combustion chamber - was assembled at Test Stand 116 at the East Test Area of the NASA Marshall Space Flight Center. The test article was well instrumented with static and dynamic pressure, temperature, and acceleration sensors to allow the collected data to be used for

  12. The Determination of 11B/10B and 87Sr/86Sr Isotope Ratios by ...

    African Journals Online (AJOL)

    NICO

    Department of Chemistry, University of Johannesburg, PO Box 524, Johannesburg, 2006, South Africa. Received 31 ... the analysis of organic wine components4,5, multi-element analysis6–10 ... and lead, has found application in the authentication of food ..... tions were loge transformed to ensure that the varying elemental.

  13. Multielement analysis of Picea rubens Sarg. Three-rings by proton-induced x-ray emission

    International Nuclear Information System (INIS)

    Hall, G.S.

    1984-01-01

    A 3.7 MeV external proton beam was employed to produce X-rays in Picea rubens Sarg. (red spruce). Intra-annual growth rings and several elements were quantitatively determined (P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Pb, Sr). The PIXE experimental set-up, rapid sample preparation methods, and some interesting observations are discussed. In addition, statistical analysis of the tree-ring element concentrations revealed that K, Cl, and Ca were slightly translocated whereas the other elements detected were not. 15 references, 1 figure, 1 table

  14. Study of Elemental Mass Distributions at Skukuza, South Afrika, during the SAFARI 2000 Dry Season Campaign

    Czech Academy of Sciences Publication Activity Database

    Maenhaut, W.; Schwarz, Jaroslav; Cafmeyer, J.; Annegarn, H. J.

    2002-01-01

    Roč. 189, - (2002), s. 254-258 ISSN 0168-583X Institutional research plan: CEZ:AV0Z4072921 Keywords : PIXE * multielement analysis * atmospheric aerosols Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.158, year: 2002

  15. Quantitative analysis of chromium concentration in nickel based alloys by laser induced breakdown spectroscopy at atmospheric pressure using a nanosecond ultraviolet Nd:YAG laser

    International Nuclear Information System (INIS)

    Gupta, G.P.; Suri, B.M.; Verma, A.; Sundararaman, M.; Unnikrishnan, V.K.; Alti, K.; Kartha, V.B.; Santhosh, C.

    2010-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been well recognized as a simple, fast and direct analytical technique of elemental analysis of multi-element materials by a number of research groups all over the world. It is based on the focusing of a high-power pulsed laser beam with a power density > 100 MW/cm 2 onto a sample surface followed by optical emission spectroscopy of the plasma produced over the surface. In the present work, they have carried out the quantitative analysis of chromium in nickel-based-alloys using laser-induced breakdown spectroscopy (LIBS) in air at atmospheric pressure. In the present work the quantitative analysis of chromium in nickel-based-alloys using laser-induced break-down spectroscopy (LIBS) in air at atmospheric pressure has been carried out

  16. Multielement analysis of Zanthoxylum bungeanum Maxim. essential oil using ICP-MS/MS.

    Science.gov (United States)

    Fu, Liang; Xie, Hualin; Shi, Shuyun

    2018-04-12

    The concentrations of trace elements (Cr, Ni, As, Cd, Hg, and Pb) in Zanthoxylum bungeanum Maxim. essential oil (ZBMEO) were determined by inductively coupled plasma tandem mass spectrometry. The ZBMEO sample was directly analyzed after simple dilution with n-hexane. Aiming for a relatively high vapor pressure of n-hexane and its resultant loading on plasma, we used a narrow injector torch and optimized plasma radio frequency power and carrier gas flow to ensure stable operation of the plasma. An optional gas flow of 20% O 2 in Ar was added to the carrier gas to prevent the incomplete combustion of highly concentrated organic carbon in plasma and the deposition of carbon on the sampling and skimmer cone orifices. In tandem mass spectrometry mode, O 2 was added to the collision/reaction cell to eliminate the interferences. The limits of detection for Cr, Ni, As, Cd, Hg, and Pb were 2.26, 1.64, 2.02, 1.35, 1.76, and 0.97 ng L -1 , respectively. After determination of 23 ZBMEO samples from different regions in China, we found that the average concentration ranges of trace elements in the 23 ZBMEO samples were 0.72-6.02 ng g -1 , 0.09-2.87 ng g -1 , 0.21-5.84 ng g -1 , 0.16-2.15 ng g -1 , 0.13-0.92 ng g -1 , and 0.17-0.73 ng g -1 for Cr, Ni, As, Cd, Hg, and Pb, respectively. The trace elements in ZBMEO differed significantly when different extraction technologies were used. The study revealed that the contents of the toxic elements As, Cd, Hg, and Pb were extremely low, and hence they are unlikely to pose a health risk following ZBMEO ingestion. Graphical abstract The working mechanism of sample analysis by ICP-MS/MS.

  17. Analytic determination of the activation of essential and toxic trace elements in biological material

    International Nuclear Information System (INIS)

    Schelenz, R.

    1980-01-01

    A neutron activation-analysis technique for the multielement determination in biological material was developed. The individual steps of this procedure comprise radiochemical and also instrumental analytic techniques. After radiochemical separation 34 elements can be determined, after only instrumental procedures 26 elements can be detected in biological material. The radiochemical analysis of 34 elements lasts 4 days. Tracer investigations on the radionuclide retention of the anorganic separators HAP, TiP and ZP in 9N aqueous HNO 3 solution indicated that apart from Na-24, K-42 and P-32 the radionuclides Cs-134, Rb-86 and Se-75 are almost quantitatively adsorbed at the separators. For the remaining investigated radionuclides different but well-reproducible retention values resulted. The pH-value only slightly influences the extent of the radionuclide retention. Kinetic investigations on the radiochemical precipitation of some radionuclides on Cu and Cu(Hg)sub(x) were carried out. The depositing of the radionuclides Ag-110m, Hg-203 and Se-75 at 0 0 C and room temperature on Cu(Hg)sub(x) and Cu foil is a first order reaction. The half-life periods and the velocity constants of the depositing on Cu and Cu(Hg)sub(x) were determined for the investigated radionuclides in dependency of the temperature. The technique was examined by means of international biological multielement standards of known element combinations. The realisation of ring tests for the multielement determination in potatoe and milk powder showed that this method provides precise results. The applicability of the radiochemical method was confirmed by the simultaneous determination of 25 elements in overall nutrition samples. The instrumental technique was applied for the multielement determination in human hair (of the head) and in river water. (orig./MG) [de

  18. Application of energy dispersive x-ray techniques for water analysis

    International Nuclear Information System (INIS)

    Funtua, I. I.

    2000-07-01

    Energy dispersive x-ray fluorescence (EDXRF) is a class of emission spectroscopic techniques that depends upon the emission of characteristic x-rays following excitation of the atomic electron energy levels by tube or isotopic source x-rays. The technique has found wide range of applications that include determination of chemical elements of water and water pollutants. Three EDXRF systems, the isotopic source, secondary target and total reflection (TXRF) are available at the Centre for Energy research and Training. These systems have been applied for the analysis of sediments, suspensions, ground water, river and rainwater. The isotopic source is based on 55 Fe, 109 Cd and 241 Am excitations while the secondary target and the total reflection are utilizing a Mo x-ray tube. Sample preparation requirements for water analysis range from physical and chemical pre-concentration steps to direct analysis and elements from Al to U can be determined with these systems. The EDXRF techniques, TXRF in particular with its multielement capability, low detection limit and possibility of direct analysis for water have competitive edge over the traditional methods of atomic absorption and flame photometry

  19. Multielement determination in Tillandsia by INAA

    International Nuclear Information System (INIS)

    Capannesi, G.; Cecchi, A.; Cecchi-Fiordi, A.

    1987-01-01

    Instrumental neutron activation analysis was employed to measure 43 elements, including some macroconstituents, in the leaves of some species of the epiphytic genus Tillandsia (Bromeliaceae). The results, confirming the oligotrophyc nature of the genus, are briefly discussed with regard to a possible role as multielemental environmental monitors. (author) 7 refs

  20. Chemical characterization of airborne particulate matter in ambient air of Nagoya, Japan, as studied by the multielement determination with ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Fukai, Taku; Kobayashi, Tatsuya; Sakaguchi, Masahiro; Aoki, Masanori; Saito, Tsuyoshi; Fujimori, Eiji; Haraguchi, Hiroki

    2007-01-01

    The multielement determination of PM 10 (airborne particulate matter smaller than 10 μm) samples, which was collected by a high volume air sampler at the urban site of Nagoya City, was carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The present analytical method was validated by analyzing urban particulate matter standard reference material of NIST SRM 1648. The analytical data for ca. 30 elements in PM 10 samples collected during a period from 8 September to 9 October, 2003, were obtained in the concentration range from sub-μg g -1 to several-10 mg g -1 , but the data for 18 elements among ca. 30 elements were available for the characterization of PM 10 samples in ambient air, because of problems caused by the filter blanks. Then, the trends concerning the distributions of diverse elements in PM 10 samples were analyzed based on the enrichment factors and size distribution factors. The lithophile and siderophile elements were distributed more than 50% in coarse particle fraction (>2.1 μm), which was derived mainly from natural sources, such as soils and crustal minerals. On the other hand, chalcophile elements were distributed more than 50% in fine particle fraction ( 10 samples as well as their mining influence factors (MIFs) suggested their wide use in industrial productions. (author)

  1. Critical Evaluation of an Intercalibration Project Focused on the Definition of New Multi-Element Soil Reference Materials (AMS-MO1 and AMS-ML1

    Directory of Open Access Journals (Sweden)

    Livia Vittori Antisari

    2014-12-01

    Full Text Available Soils are complex matrices and their geochemical investigation necessarily needs reliable Certified Reference Materials (CRMs, i.e. standards, to support analytical precision and accuracy. In particular, the definition of soil multi-element CRMs is particularly complex and involves an inter-laboratory program that employs numerous analytical techniques. In this study, we present the results of the inter-calibration experiment focused on the certification of two new soil standards named AMS-ML1 and AMS-MO1. The two soils developed on sandstone and serpentinite parent materials, respectively. The experiment involved numerous laboratories and focused on the evaluation of soil physicochemical parameters and geochemical analyses of major and trace elements by X-ray fluorescence (XRF and Inductive Coupled Plasma techniques (ICP-OES and ICP-MS. The data was statistically elaborated. Three levels of repeatability and accuracy in function of the different analytical methods and instrumentation equipment was observed. The statistical evaluation of the results obtained by ICP-OES on Aqua Regia extracts (i.e., Lilliefors test for normally, Grubbs test for outliers, Cochran test for outliers in variances and ANOVA allowed to computed some certified values for the two proposed soil standards. This preliminary study will represent the first step of a more thorough intercalibration ring-test involving a higher number of laboratories, in order to propose the investigated matrices as CRMs.

  2. A computer program to evaluate the experimental data in instrumental multielement neutron activation analysis

    International Nuclear Information System (INIS)

    Greim, L.; Motamedi, K.; Niedergesaess, R.

    1976-01-01

    A computer code evaluating experimental data of neutron activation analysis (NAA) for determination of atomic abundancies is described. The experimental data are, beside a probe designation, the probe weight, irradiation parameters and a Ge(Li)-pulse-height-spectrum from the activity measurement. The organisation of the necessary nuclear data, comprising all methods of activation in reactor-irradiations, is given. Furthermore the automatic evaluation of spectra, the designation of the resulting peaks to nuclei and the calculation of atomic abundancies are described. The complete evaluation of a spectrum with many lines, e.g. 100 lines of 20 nuclei, takes less than 1 minute machine-time on the TR 440 computer. (orig.) [de

  3. Applications of neutron activation analysis technique

    International Nuclear Information System (INIS)

    Jonah, S. A.

    2000-07-01

    The technique was developed as far back as 1936 by G. Hevesy and H. Levy for the analysis of Dy using an isotopic source. Approximately 40 elements can be analyzed by instrumental neutron activation analysis (INNA) technique with neutrons from a nuclear reactor. By applying radiochemical separation, the number of elements that can be analysed may be increased to almost 70. Compared with other analytical methods used in environmental and industrial research, NAA has some unique features. These are multi-element capability, rapidity, reproducibility of results, complementarity to other methods, freedom from analytical blank and independency of chemical state of elements. There are several types of neutron sources namely: nuclear reactors, accelerator-based and radioisotope-based sources, but nuclear reactors with high fluxes of neutrons from the fission of 235 U give the most intense irradiation, and hence the highest available sensitivities for NAA. In this paper, the applications of NAA of socio-economic importance are discussed. The benefits of using NAA and related nuclear techniques for on-line applications in industrial process control are highlighted. A brief description of the NAA set-ups at CERT is enumerated. Finally, NAA is compared with other leading analytical techniques

  4. Multielement determination and speciation of major-to-trace elements in black tea leaves by ICP-AES and ICP-MS with the aid of size exclusion chromatography

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Katsuki, Fumie; Itoh, Akihide; Haraguchi, Hiroki

    2001-01-01

    A multielement determination of major-to-trace elements in black tea leaves and their tea infusions was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). Tea infusions were prepared as usual tea beverage by brewing black tea leaves in boiling water for 5 min. About 40 elements in tea leaves and tea infusions could be determined over the wide concentration range in 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusions to that in tea leaves. From the experimental results for the extraction efficiencies, the elements in black tea leaves were classified into three characteristic groups: (i) highly-extractable elements (>55%): Na, K, Co, Ni, Rb, Cs and Tl, (ii) moderately-extractable elements (20-55%): Mg, Al, P, Mn and Zn, and (iii) poorly-extractable elements (<20%): Ca, Fe, Cu, Sr, Y, Zr, Mo, Sn, Ba and lanthanoid elements. Furthermore, speciation of major-to-trace elements in tea infusions was performed by using a combined system of size exclusion chromatography (SEC) and ICP-MS (or ICP-AES). As a result, many diverse elements were found to be present as complexes associated with large organic molecules in tea infusions. (author)

  5. Ion induced x-ray emission

    International Nuclear Information System (INIS)

    Cohen, D.D.; Clayton, E.

    1989-01-01

    This paper discusses particle induced x-ray emission (PIXE). Its use as a tool for multi-element non-destructive trace element analysis of small samples is addressed. Concepts and details needed for the construction of a PIXE system are offered

  6. SmaggIce 2.0: Additional Capabilities for Interactive Grid Generation of Iced Airfoils

    Science.gov (United States)

    Kreeger, Richard E.; Baez, Marivell; Braun, Donald C.; Schilling, Herbert W.; Vickerman, Mary B.

    2008-01-01

    The Surface Modeling and Grid Generation for Iced Airfoils (SmaggIce) software toolkit has been extended to allow interactive grid generation for multi-element iced airfoils. The essential phases of an icing effects study include geometry preparation, block creation and grid generation. SmaggIce Version 2.0 now includes these main capabilities for both single and multi-element airfoils, plus an improved flow solver interface and a variety of additional tools to enhance the efficiency and accuracy of icing effects studies. An overview of these features is given, especially the new multi-element blocking strategy using the multiple wakes method. Examples are given which illustrate the capabilities of SmaggIce for conducting an icing effects study for both single and multi-element airfoils.

  7. Multi-element RIMS Analysis of Genesis Solar Wind Collectors

    Science.gov (United States)

    Veryovkin, I. V.; Tripa, C. E.; Zinovev, A. V.; King, B. V.; Pellin, M. J.; Burnett, D. S.

    2009-12-01

    The samples of Solar Wind (SW) delivered by the NASA Genesis mission, present significant challenges for surface analytical techniques, in part due to severe terrestrial contamination of the samples on reentry, in part due to the ultra-shallow and diffused ion implants in the SW collector materials. We are performing measurements of metallic elements in the Genesis collectors using Resonance Ionization Mass Spectrometry (RIMS), an ultra-sensitive analytical method capable of detecting SW in samples with lateral dimensions of only a few mm and at concentrations from above one ppm to below one ppt. Since our last report at 2008 AGU Fall Meeting, we have (a) developed and tested new resonance ionization schemes permitting simultaneous measurements of up to three (Ca, Cr, and Mg) elements, and (b) improved reproducibility and accuracy of our RIMS analyses for SW-like samples (i.e. shallow ion implants) by developing and implementing an optimized set of new analytical protocols. This is important since the quality of scientific results from the Genesis mission critically depends on the accuracy of analytical techniques. In this work, we report on simultaneous RIMS measurements of Ca and Cr performed on two silicon SW collector samples, (#60179 and #60476). First, we have conducted test experiments with 3×1013 at/cm2 52Cr and 44Ca implants in silicon to evaluate the accuracy of our quantitative analyses. Implant fluencies were measured by RIMS to be 2.73×1013 and 2.71×1013 at/cm2 for 52Cr and 44Ca, respectively, which corresponds to an accuracy of ≈10%. Using the same implanted wafer as a reference, we conducted RIMS analyses of the Genesis samples: 3 spots on #60179 and 4 spots on #60476. The elemental SW fluencies expected for Cr and Ca are 2.95×1010 and 1.33×1011 at/cm2 , respectively. Our measurements of 52Cr yielded 3.0±0.6×1011 at/cm2 and 5.1±4.1×1010 at/cm2 for #60179 and #60476, respectively. For 40Ca, SW fluencies of 1.39±0.70×1011 at/cm2 in #60179 and 3.6±2.5×1013 at/cm2 in #60476 were measured. Thus, only one element in each sample showed reasonable agreement with the expected values, Ca in #60179 and Cr in #60476. However the cleaning procedures applied to these samples were different: #60179 was only Megasonicated in ultra-pure water, while #60476 was subjected to longer Megasonication and an RCA cleaning procedure involving multiple rinsing steps with acid solutions. It is apparent that the surface contamination and cleaning procedures influenced the results of our measurements. We will present these experimental results and discuss procedures - including improved sample cleaning, dual-beam high resolution sputter depth profiling from front and back sides of the sample, and modeling of near-surface impurity transport - aimed at improving the accuracy of determination of elemental abundances by ion sputtering based analytical methods. This work is supported by NASA through a grant NNH08AH761 and by UChicago Argonne, LLC, under contract No. DE-AC02-06CH11357.

  8. Multielement determination in water by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Naeem, A.

    1987-01-01

    INAA technique was applied to a water sample to determine the elemental concentrations. The sample was irradiated with a neutron flux of 1.2x10 12 n cm -2 s -1 for two different decay times, using two coaxial type high-resolution Ge(Li) detectors. The dominant elements determined in the water sample are Ca, Cl, Na, Mg and K present in ppm-level, while Co, I, Mn, Sm, and Sb are present in smaller amounts, approx. on the average 0.01 ppm. Only traces of other elements such as the rare-earths Ag, As, Ba, Cu, Cd, Fe, Sr, W, Zn, seem to be present. (author)

  9. Scanning SRXF analysis and isotopes of uranium series from bottom sediments of Siberian lakes for high-resolution climate reconstructions

    International Nuclear Information System (INIS)

    Goldberg, E.L.; Grachev, M.A.; Chebykin, E.P.; Phedorin, M.A.; Kalugin, I.A.; Khlystov, O.M.; Zolotarev, K.V.

    2005-01-01

    High-resolution scanning X-ray Fluorescence Analysis with Synchrotron Radiation (SRXFA) was applied to investigate the downcore distribution of elements in Lake Baikal and Lake Teletskoye. Physical modeling of river runoff taking into account the chemistry of U series isotopes and their concentrations in sediments allowed a decade-scale reconstruction of Holocene (0-11 ky) river input to Lake Baikal. Holocene moisture peaks in East Siberia are synchronous with abrupt spells in the Atlantic. The multi-element data from Lake Teletskoye were used to predict the function of geochemical response to climate change in plainland Altai and to reconstruct the trends of annual (winter) air temperatures and atmospheric precipitation for the past 500 years

  10. Characterization of primary geochemical haloes for gold exploration at the Huanxiangwa gold deposit, China

    NARCIS (Netherlands)

    Wang, Changming; Carranza, E.J.M; Zhang, Shouting; Zhang, Jing; Liu, Xiaoji Liu; Zhang, Da; Sun, Xiang; Duan, Cunji

    2013-01-01

    Recognition of primary geochemical haloes is one of the most important tools for exploring undiscovered mineral resources. This tool is being routinely applied in exploration programs at the Huanxiangwa gold deposit, Xiong'er Mountains, China. Sampling of unweathered rock for multi-element analysis

  11. Precision of neutron activation analysis for environmental biological materials

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroshi; Iwata, Shiro; Koyama, Mutsuo; Sasajima, Kazuhisa; Numata, Yuichi.

    1977-01-01

    Between 1973 and 1974 a special committee ''Research on the application of neutron activation analysis to the environmental samples'' had been organized at the Research Reactor Institute, Kyoto University. Eleven research groups composed mainly of the committee members cooperated in the intercomparison programme of the reactor neutron activation analysis of NBS standard reference material, 1571 Orchard Leaves and 1577 Bovine Liver. Five different type of reactors were used for the neutron irradiation; i.e. KUR reactor of the Research Reactor Institute, Kyoto University, TRIGA MARK II reactor of the Institute for Atomic Energy, Rikkyo University, and JRR-2, JRR-3, JRR-4 reactor of Japan Atomic Energy Research Institute. Analyses were performed mainly by instrumental method. Precision of the analysis of 23 elements in Orchard Leaves and 13 elements in Bovine Liver presented by the different research groups was shown in table 4 and 5, respectively. The coefficient of variation for these elements was from several to -- 30 percent. Averages given to these elements agreed well with the NBS certified or reference values. Thus, from the practical point of view for the routine multielement analysis of environmental samples, the validity of the instrumental neutron activation technique for this purpose has been proved. (auth.)

  12. Study on the identification method of chemical warfare agents with spectroscopy of neutron induced γ rays

    International Nuclear Information System (INIS)

    Liu Boxue; Li Yun; Li Xiangbao

    1996-01-01

    The paper briefly describes some non-destructive verification technologies of chemical warfare agents in-site, and some application of neutron induced gamma ray analysis, such as multi-elements analysis of coal, hidden explosive detection and identification of chemical agents. It also describes some problems in developing the portable isotopic neutron spectroscopy for non-destructive evaluation of chemical warfare agents

  13. The quantitative determination of trace elements in giant unicellular plants by particle-induced X-ray emission

    International Nuclear Information System (INIS)

    Navarrete-Dominguez, V.R.; Yoshihara, K.; Tanaka, N.

    1982-01-01

    Particle-induced X-ray emission (PIXE) was applied for the determination of trace elements in biologically interesting materials, giant unicellular plants. It was found that the PIXE method had advantages in multi-element trace analysis of a single cell of the sample plant. (author)

  14. Charged-particle activation analysis

    International Nuclear Information System (INIS)

    Schweikert, E.A.

    1978-01-01

    The paper discusses the methodology and application of nuclear activation with ion beams (1 9 via 16 O( 3 He,p) 18 F, 12 C( 3 He,α) 11 C and 14 N(p,α) 11 C respectively. Recently, triton activation has been shown to be inherently still superior to 3 He activation for the determination of oxygen [ 16 O( 3 H,n) 18 F]. Lithium, boron, carbon and sulphur can be detected rapidly, nondestructively and with high sensitivity (approximately 0.25ppm for Li and B) via ''quasi-prompt'' activation based on the detection of short-lived, high-energy beta emitters (10ms 1 H( 7 Li,n) 7 Be for example. Nondestructive multielement analysis: Proton activation has the inherent potential for meeting requirements of broad elemental coverage, sensitivity (ppm and sub-ppm range) and selectivity. Up to 30 elements have been determined in Al, Co, Ag, Nb, Rh, Ta and biological samples, using 12-MeV proton activation followed by gamma-ray spectrometry. These capabilities are further enhanced with the counting of X-ray emitters, 28 elements (26 9 ) and accuracy using proton activation. 204 Pb/ 206 Pb ratios can also be determined with a relative precision of a few per cent. Although charged-particle activation analysis is a well-established trace analysis technique, broad potential capabilities remain to be explored, e.g. those arising from ultrashort-lived nuclides, heavy ion interactions and the combination of delayed and prompt methods. (author)

  15. Environmental monitoring near urban lead refineries by photon and neutron activation analysis

    International Nuclear Information System (INIS)

    Paciga, J.J.; Chattopadhyay, A.; Jervis, R.E.

    1974-01-01

    Photon activation has been used in conjunction with neutron activation for multielement determinations in airborne particulates, soil, and hair samples collected near two secondary lead refineries in Metropolitan Toronto. Particle size distributions of suspended particulates collected with a high volume Andersen sampler are reported for Al, Sb, As, Br, Cl, Mn, Na, Pb, Ti and V. Increases in the concentrations of Pb, As and Sb associated with particles >3.3 μm diameter on certain days near the refineries has resulted in localized contamination as reflected in higher concentrations of these elements in soil. To assess Pb accumulation in local residents compared with control groups, approximately 250 hair samples were analyzed for Pb by photon activation analysis. Children living close to the refineries, especially boys, exhibit the most elevated levels: up to 20 times urban control values in some cases

  16. Quantitative analysis of Si1-xGex alloy films by SIMS and XPS depth profiling using a reference material

    Science.gov (United States)

    Oh, Won Jin; Jang, Jong Shik; Lee, Youn Seoung; Kim, Ansoon; Kim, Kyung Joong

    2018-02-01

    Quantitative analysis methods of multi-element alloy films were compared. The atomic fractions of Si1-xGex alloy films were measured by depth profiling analysis with secondary ion mass spectrometry (SIMS) and X-ray Photoelectron Spectroscopy (XPS). Intensity-to-composition conversion factor (ICF) was used as a mean to convert the intensities to compositions instead of the relative sensitivity factors. The ICFs were determined from a reference Si1-xGex alloy film by the conventional method, average intensity (AI) method and total number counting (TNC) method. In the case of SIMS, although the atomic fractions measured by oxygen ion beams were not quantitative due to severe matrix effect, the results by cesium ion beam were very quantitative. The quantitative analysis results by SIMS using MCs2+ ions are comparable to the results by XPS. In the case of XPS, the measurement uncertainty was highly improved by the AI method and TNC method.

  17. Multielement analysis of Nigerian chewing sticks by cyclic neutron activation analysis (CNAA)

    Energy Technology Data Exchange (ETDEWEB)

    Adesanmi, C.A.

    1989-01-01

    CNAA is used to analyse nine plant species commonly used for teeth brushing in Nigeria. The operational conditions are defined and applied to determine Dy, Sc, Se, Hf, Rb, Cl, F, Mn, Al and Ca. Concentration levels in the range of ..mu..g/g were easily detected and quantitatively measured.

  18. Spatially resolved element analysis of historical violin varnishes by use of muPIXE.

    Science.gov (United States)

    von Bohlen, Alex; Röhrs, Stefan; Salomon, Joseph

    2007-02-01

    External muPIXE has been used for characterisation of small samples of varnish from historical violins, and pieces of varnished wood from historical and modern stringed instruments. To obtain spatially resolved information about the distribution of elements across the varnish layers single-spot analysis, line-scans, and area-mapping were performed. Local resolution of approximately 20 mum was obtained from the 3 MeV, 1 nA proton micro-probe. Results from simultaneous multi-element determination of Na, Mg, Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Rb, Sr, Ag, Cd, Sn, Ba, and Pb in historical varnishes are presented. Semi-quantitative evaluation of line-scans recorded on diverse historical varnishes is reported. The applied method is discussed in detail and the results obtained are critically reviewed and compared with those in the literature.

  19. Tracking transformation processes of organic micropollutants in aquatic environments using multi-element isotope fractionation analysis

    International Nuclear Information System (INIS)

    Hofstetter, Thomas B.; Bolotin, Jakov; Skarpeli-Liati, Marita; Wijker, Reto; Kurt, Zohre; Nishino, Shirley F.; Spain, Jim C.

    2011-01-01

    The quantitative description of enzymatic or abiotic transformations of man-made organic micropollutants in rivers, lakes, and groundwaters is one of the major challenges associated with the risk assessment of water resource contamination. Compound-specific isotope analysis enables one to identify (bio)degradation pathways based on changes in the contaminants' stable isotope ratios even if multiple reactive and non-reactive processes cause concentrations to decrease. Here, we investigated how the magnitude and variability of isotope fractionation in some priority pollutants is determined by the kinetics and mechanisms of important enzymatic and abiotic redox reactions. For nitroaromatic compounds and substituted anilines, we illustrate that competing transformation pathways can be assessed via trends of N and C isotope signatures.

  20. 100 mg 251Cf activation analysis facility at the Savannah River Laboratory

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1975-01-01

    The 252 Cf Activation Analysis Facility at the Savannah River Laboratory (SRL) is used routinely for multielement analyses of a wide variety of solid and liquid samples (e.g., metal alloys, fly ash and other airborne particles, rocks, and aqueous and nonaqueous solutions). An automated absolute activation analysis technique, developed to use neutron transport codes to calculate multienergy group neutron spectra and fluxes, converts counting data directly into elemental concentrations expressed in parts per million. The facility contains four sources of 252 Cf totaling slightly over 100 mg. A pneumatic ''rabbit'' system permits automatic irradiation/decay/counting regimes to be performed unattended on up to 100 samples. Detection sensitivities of less than or equal to 400 ppb natural uranium and less than or equal to 0.5 nCi/g for 239 Pu are observed. Detection limits for over 65 elements have been determined. Over 40 elements are detectable at the one part per million level or less. Overall accuracies of +- 10 percent are observed for most elements. (auth)

  1. Multi-element analysis of bone from the osteogenesis imperfecta model (OIM) mouse using thermal and fast neutron activation analysis

    International Nuclear Information System (INIS)

    Huntington, C.E.; Morris, J.S.; Carleton, S.M.; McBride, D.J.; Phillips, C.L.

    2008-01-01

    Osteogenesis imperfecta (OI) is a heritable osteoporotic bone disease, due to defects in either type I procollagen genes (COL1A1 or COL1A2), resulting in abnormal and/or reduced levels of type I procollagen and alterations in bone mineralization. Our long term objectives are to evaluate the impact of proα1(I) and proα2(I) collagen mutations and the role of the genetic background on bone mineralization. Tibias from wildtype, heterozygous (oim/+), and homozygous (oim/oim) animals were subjected to instrumental neutron activation analysis (INAA) to measure F, P, Na, Mg, Cl, Ca, K, and Zn using the University of Missouri Research Reactor (MURR) pneumatic-tube irradiation facility. (author)

  2. Development of a database for prompt γ-ray neutron activation analysis. Summary report of the first research coordination meeting

    International Nuclear Information System (INIS)

    Paviotti-Corcuera, R.; Lindstrom, R.M.

    2000-02-01

    This report summarizes the presentations, recommendations and conclusions of the First Research Co-ordination Meeting on Development of a Database for Prompt γ-ray Neutron Activation Analysis. Neutron-capture Prompt γ-ray Activation Analysis (PGAA) is a non-destructive radioanalytical method, capable of rapid or in-situ simultaneous multielement analysis of many elements of the Periodic Table, from hydrogen to uranium, in the same sample. Inaccuracy and incompleteness of the data available for use in PGAA are a significant handicap in the qualitative and quantitative analysis of capture-gamma spectra. The goal of this CRP is to replace the twenty-year-old data from a single laboratory with something fundamentally new: an evaluated database which includes a combination of evaluated nuclear physics data, physical theory, and recent measurements. The resulting database will be comparable in quality with that for radioactive decay. In addition, more accurate values of neutron capture cross-sections and γ-ray intensities that result from this database will improve the accuracy of radiation shielding calculations. (author)

  3. An automated wavelength selection for flame spectroscopy

    International Nuclear Information System (INIS)

    Hurteau, M.; Mislan, J.P.; Ashley, R.W.

    1976-01-01

    A simple electro-mechanical programming system is described for use with a flame spectrophotometer. Its application for automated sequential multi-element analysis is illustrated. Reproducibility of wavelength settings are within +-0.5 A. Precision and sensitivities are at least as good as those obtained for single element determinations. (author)

  4. Review and evaluation of spark source mass spectrometry as an analytical method

    International Nuclear Information System (INIS)

    Beske, H.E.

    1981-01-01

    The analytical features and most important fields of application of spark source mass spectrometry are described with respect to the trace analysis of high-purity materials and the multielement analysis of technical alloys, geochemical and cosmochemical, biological and radioactive materials, as well as in environmental analysis. Comparisons are made to other analytical methods. The distribution of the method as well as opportunities for contract analysis are indicated and developmental tendencies discussed. (orig.) [de

  5. Application of ko-NAA technique on Dalat research reactor for human hair analysis in environmental pollution study

    International Nuclear Information System (INIS)

    Ho Manh Dung; Mai Van Nhon

    2006-01-01

    The k o -standardization method of neutron activation analysis (k o -NAA) has recently been developed on Dalat research reactor. However, in order to apply the k o -NAA technique for practical research objects, it is necessary to establish different experimental procedures for each object. This work is aiming at establishing such a k o -NAA procedure on Dalat research reactor for human hair samples to solve the environmental pollution study prob;em. Therefore, the sample collection and preparation, irradiation, gamma-ray spectrum measurement and data processing, as well as quality assurance and quality control of the k o -NAA procedure for human hair samples have been assessed by comparing with elemental concentrations in terms of the experimental to certified values ratio and U-score. The experimental results showed that the k o -NAA for multi-element in human hair sample analysis is able to apply on Dalat research reactor with a rather good analytical quality. (author)

  6. Instrumental neutron activation analysis of prehistoric and ancient bone remains

    International Nuclear Information System (INIS)

    Vasidov, A.; Osinskaya, N.S.; Khatamov, Sh.; Rakhmanova, T.

    2008-01-01

    Instrumental neutron activation analysis (INAA) was used to study the element contents in bones of prehistoric dinosaurs and bones of an ancient bear and an archantrop (ancient person), which were found on the territory of Uzbekistan. Concentrations of more than 25 elements were in the range of 0.043-3600 mg/kg. Multielement analyses of bone and soil samples were carried out by INAA using the WWR-SM research nuclear reactor. Results of measurements have shown that in the dinosaurs bones the concentration of the rare earth elements (REEs) were within 280-3200 mg/kg; the uranium content reached a very high value, up to 180 mg/kg, while in soils coating the dinosaurs bones this content was 4.2 mg/kg; in the bones of the archantrop it was 1.53 mg/kg and in the bones of a standard person its amount is less than 0.016 mg/kg. (author)

  7. Multielement determination in a Chinese cigarette brand

    International Nuclear Information System (INIS)

    Iskander, F.Y.

    1992-01-01

    A cigarette brand manufactured in the Republic of China was analyzed by instrumental neutron activation analysis to determine the concentration of 27 elements in cigarette tobacco, cigarette wrapping paper, cigarette filter before and after smoking and in the dropped ash. The results were compared to the literature values for American and other international cigarette brands. (author) 28 refs.; 3 tabs

  8. Comparison of Chinese and European k0 software

    International Nuclear Information System (INIS)

    Sasajima, Fumio

    2004-01-01

    The element determination by neutron activation analysis is commonly done by the relative method using comparison standard materials. However, when a simultaneous multi-element analysis of an unknown sample is carried out, this method requires an advance preparation of reference material for each content element, their simultaneous irradiation with the sample, and measurement in a same condition. It is indeed a demanding technique with the laborious work such as arranging reference materials. On the other hand, the k 0 method does not usually require reference materials, and allows easier and more accurate simultaneous multi-element analysis, therefore it is widely practiced in many countries including European nations. This report describes two kinds of k 0 software (KAYZERO/SOLCOI, ADVNAA) on their characteristics and the results of environmental standard sample (NIST 1632c, NIES No.8, JB-3) analyses using those software. As a result, both of those software accomplished an accuracy within about 10% in analysis of all but a few elements. They have both drawbacks and advantages in their characteristics and features, although it might not be reasonable to compare two products with different development purposes. commercial, or personal use. (author)

  9. Computer analysis to the geochemical interpretation of soil and stream sediment data in an area of Southern Uruguay

    International Nuclear Information System (INIS)

    Spangenberg, J.

    2010-01-01

    In southern Uruguay there are several known occurrences of base metal sulphide mineralization within an area of Precambrian volcanic sedimentary rocks. Regional geochemical stream sediment reconnaissance surveys revealed new polymetallic anomalies in the same stratigraphic zone. Geochemical interpretation of multi-element data from a soil and stream sediment survey carried out in one of these anomalous areas is presented.

  10. Eigenvalue distributions of correlated multichannel transfer matrices in strongly scattering systems

    NARCIS (Netherlands)

    Sprik, R.; Tourin, A.; de Rosny, J.; Fink, M.

    2008-01-01

    We experimentally study the effects of correlations in the propagation of ultrasonic waves in water from a multielement source to a multielement detector through a strongly scattering system of randomly placed vertical rods. Due to the strong scattering, the wave transport in the sample is in the

  11. [Rapid multi-elemental analysis on four precious Tibetan medicines based on LIBS technique].

    Science.gov (United States)

    Liu, Xiao-na; Shi, Xin-yuan; Jia, Shuai-yun; Zhao, Na; Wu, Zhi-sheng; Qiao, Yan-jiang

    2015-06-01

    The laser-induced breakdown spectroscopy (LIBS) was applied to perform a qualitative elementary analysis on four precious Tibetan medicines, i. e. Renqing Mangjue, Renqing Changjue, 25-herb coral pills and 25-herb pearl pills. The specific spectra of the four Tibetan medicines were established. In the experiment, Nd: YAG and 1 064 nm-baseband pulse laser were adopted to collect the spectra. A laser beam focused on the surface of the samples to generate plasma. Its spectral signal was detected by using spectrograph. Based on the National Institute of Standard and Technology (NIST) database, LIBS spectral lines were indentified. The four Tibetan medicines mainly included Ca, Na, K, Mg and other elements and C-N molecular band. Specifically, Fe was detected in Renqing Changjue and 25-herb pearl pills; heavy mental elements Hg and Cu were shown in Renqing Mangjue and Renqing Changjue; Ag was found in Renqing Changjue. The results demonstrated that LIBS is a reliable and rapid multi-element analysis on the four Tibetan medicines. With Real-time, rapid and nondestructive advantages, LIBS has a wide application prospect in the element analysis on ethnic medicines.

  12. Design and Fabrication of Oxygen/RP-2 Multi-Element Oxidizer-Rich Staged Combustion Thrust Chamber Injectors

    Science.gov (United States)

    Garcia, C. P.; Medina, C. R.; Protz, C. S.; Kenny, R. J.; Kelly, G. W.; Casiano, M. J.; Hulka, J. R.; Richardson, B. R.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. On the current project, several configurations of new main injectors were considered for the thrust chamber assembly of the integrated test article. All the injector elements were of the gas-centered swirl coaxial type, similar to those used on the Russian oxidizer-rich staged-combustion rocket engines. In such elements, oxidizer-rich combustion products from the preburner/turbine exhaust flow through a straight tube, and fuel exiting from the combustion chamber and nozzle regenerative cooling circuits is injected near the exit of the oxidizer tube through tangentially oriented orifices that impart a swirl motion such that the fuel flows along the wall of the oxidizer tube in a thin film. In some elements there is an orifice at the inlet to the oxidizer tube, and in some elements there is a sleeve or "shield" inside the oxidizer tube where the fuel enters. In the current project, several variations of element geometries were created, including element size (i.e., number of elements or pattern density), the distance from the exit of the sleeve to the injector face, the width of the gap between the oxidizer tube inner wall and the outer wall of the sleeve, and excluding the sleeve entirely. This paper discusses the design rationale for each of these element variations, including hydraulic, structural

  13. Progress report on neutron activation analysis at Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, Nguyen Ngoc [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Neutron Activation Analysis (NAA) is one of most powerful techniques for the simultaneous multi-elements analysis. This technique has been studied and applied to analyze major, minor and trace elements in Geological, Biological and Environmental samples at Dalat Nuclear Research Reactor. At the sixth Workshop, February 8-11, 1999, Yojakarta, Indonesia we had a report on Current Status of Neutron Activation Analysis using Dalat Nuclear Research Reactor. Another report on Neutron Activation Analysis at the Dalat Nuclear Research Reactor also was presented at the seventh Workshop in Taejon, Korea from November 20-24, 2000. So in this report, we would like to present the results obtained of the application of NAA at NRI for one year as follows: (1) Determination of the concentrations of noble, rare earth, uranium, thorium and other elements in Geological samples according to requirement of clients particularly the geologists, who want to find out the mineral resources. (2) The analysis of concentration of radionuclides and nutrient elements in foodstuffs to attend the program on Asian Reference Man. (3) The evaluation of the contents of trace elements in crude oil and basement rock samples to determine original source of the oil. (4) Determination of the elemental composition of airborne particle in the Ho Chi Minh City for studying air pollution. The analytical data of standard reference material, toxic elements and natural radionuclides in seawater are also presented. (author)

  14. Progress report on neutron activation analysis at Dalat Nuclear Research Reactor

    International Nuclear Information System (INIS)

    Tuan, Nguyen Ngoc

    2003-01-01

    Neutron Activation Analysis (NAA) is one of most powerful techniques for the simultaneous multi-elements analysis. This technique has been studied and applied to analyze major, minor and trace elements in Geological, Biological and Environmental samples at Dalat Nuclear Research Reactor. At the sixth Workshop, February 8-11, 1999, Yojakarta, Indonesia we had a report on Current Status of Neutron Activation Analysis using Dalat Nuclear Research Reactor. Another report on Neutron Activation Analysis at the Dalat Nuclear Research Reactor also was presented at the seventh Workshop in Taejon, Korea from November 20-24, 2000. So in this report, we would like to present the results obtained of the application of NAA at NRI for one year as follows: (1) Determination of the concentrations of noble, rare earth, uranium, thorium and other elements in Geological samples according to requirement of clients particularly the geologists, who want to find out the mineral resources. (2) The analysis of concentration of radionuclides and nutrient elements in foodstuffs to attend the program on Asian Reference Man. (3) The evaluation of the contents of trace elements in crude oil and basement rock samples to determine original source of the oil. (4) Determination of the elemental composition of airborne particle in the Ho Chi Minh City for studying air pollution. The analytical data of standard reference material, toxic elements and natural radionuclides in seawater are also presented. (author)

  15. Multielement proton-induced x-ray emission analysis of Bangladeshi tobacco

    International Nuclear Information System (INIS)

    Hadi, D.A.; Ali, M.; Biswas, S.K.; Islam, M.M.; Khan, A.H.

    1984-01-01

    The concentration of 12 different elements in cigarette tobacco of different brands, commercially made in Bangladesh, was determined using the proton particle-induced x-ray emission (proton PIXE) method. In all the present experiments, proton beams of 2.0 MeV (on the target in air) and about 30 nA current were used for characteristic x-ray excitation. The concentration of the elements (K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb and Sr) was determined by comparison with a calibration obtained from the NBS orchard leaf standard SRM 1571. The results have been compared with available data on some foreign brands of tobacco and the probable reasons for the difference in the contents of some of the elements found in the Bangladeshi brands are discussed. (author)

  16. Multielement analysis of minerals from Madagascar by X-ray emission induced by protons and gamma rays

    International Nuclear Information System (INIS)

    Rakotoarisoa, C.

    1990-12-01

    This study is a part of a large multidisciplinary program for the study of soil formation in the south east of Madagascar near the uranothorianite deposit of Tranomaro explaining the particular interest for rare earths, uranium and thorium. X-ray emission principles and physical processes of a X-ray spectra are briefly recalled. The choice of analysis method depends upon sensitivity simplicity and rapidity. Experimental techniques are described and results obtained are discussed. Methods used for qualitative and quantitative interpretation of spectra are exposed. In conclusion performance and limits of the method are examined [fr

  17. Field-portable high-resolution EDXRF analysis with HgI2-detector-based instrumentation

    International Nuclear Information System (INIS)

    Berry, P.F.; Little, S.R.; Voots, G.R.

    1992-01-01

    Energy dispersive x-ray fluorescence (EDXRF) analysis is well known for its efficient use of x-ray detector technology for simultaneous multielement determination. Low-intensity excitation, such as from a radioisotope source, can thus be employed and has enabled the design of many types of truly portable EDXRF instrumentation. Portable design, however, has not been without significant compromise in analytical performance because of the limited x-ray resolving power of prior detection methods, except by the use of a cryogenically operated detector. The developments we refer to stem from the use of a comparatively new x-ray detection device fabricated from mercuric iodide (HgI 2 ). For this detector, only a modest degree of cooling is required to achieve an energy resolution of > 300 eV. Two field-portable instrument designs of different hand-held measurement probe configurations are available that have applications for industrial quality assurance and environmental screening

  18. Use of L-cysteine for minimization of inorganic Hg loss during thermal neutron irradiation

    International Nuclear Information System (INIS)

    Anderson, D.L.

    2009-01-01

    Thermal neutron irradiation experiments performed with cellulose-based L-cysteine-treated and untreated Hg standards showed Hg losses of 59-81% for untreated standards but only about a 0.2% loss for treated standards. These results and others for multielement standards showed that Hg loss is highly dependent on total mass and placement of materials in the irradiation vessel and that distribution of volatilized Hg was fairly uniform throughout the sample-containing region of the vessel. Polyethylene trapped volatile Hg much more efficiently than cellulose and a multielement standard containing inorganic Se selectively trapped Hg lost from a co-irradiated multielement standard containing Hg. (author)

  19. Microstrip Antenna Design for Femtocell Coverage Optimization

    Directory of Open Access Journals (Sweden)

    Afaz Uddin Ahmed

    2014-01-01

    Full Text Available A mircostrip antenna is designed for multielement antenna coverage optimization in femtocell network. Interference is the foremost concern for the cellular operator in vast commercial deployments of femtocell. Many techniques in physical, data link and network-layer are analysed and developed to settle down the interference issues. A multielement technique with self-configuration features is analyzed here for coverage optimization of femtocell. It also focuses on the execution of microstrip antenna for multielement configuration. The antenna is designed for LTE Band 7 by using standard FR4 dielectric substrate. The performance of the proposed antenna in the femtocell application is discussed along with results.

  20. X-ray fluorescence determination of cobalt in iron-manganese oceanic concretions

    International Nuclear Information System (INIS)

    Ivanenko, V.V.; Kustov, V.N.; Metelev, A.Yu.; Rakita, K.A.

    1989-01-01

    A method was developed for resolution of weak analytical lines for elements determined by radionuclide-excited X-ray fluorescence multi-element analysis. The method was used aboart for determining cobalt and some other commercially valuable elements in iron-manganese concretions of Pacific ocean 109 Cd was used as an ionizing radiation source

  1. Evaluation of Graduated vs All-or-None Contingencies on Rate Tasks for Individuals Diagnosed with Autism

    Science.gov (United States)

    Kassardjian, Alyne; Leaf, Jeremy A.; Leaf, Justin B.; Townley-Cochran, Donna; Alcalay, Aditt; Milne, Christine; Dale, Stephanie; Tsuji, Kathleen; Leaf, Ronald; Taubman, Mitchell; McEachin, John

    2016-01-01

    The graduated reinforcement procedure (also known as differential reinforcement) is an often-used procedure in the field of Applied Behavior Analysis to teach new skills and increase pro-social behaviors. In this study, the researchers used a multi-element design to evaluated the graduated reinforcement procedure for six children with a diagnosis…

  2. Trace element determination in plant material by means of instrumental neutron activation analysis (INAA) with special reference to molybdenum

    International Nuclear Information System (INIS)

    Schnier, C.; Schnug, E.

    1981-01-01

    The instrumental neutron activation analysis (INAA) permits a non-destructive multielement determination of minute trace element concentrations in organic material. No sample preparation except drying is required. Especially for the determination of molybdenum the INAA offers great advantages compared to the methods used in agricultural chemistry where complicated enrichment and extraction steps are needed. Contamination by reagents or loss of elements are not potential sources of errors. The principle, the advantages and disadvantages of INAA are described. The method is demonstrated with the example of celery samples from an experiment with five different nitrogen fertilizers on contaminated soil and of cabbage samples from an uncontaminated region. Besides molybdenum, 19 other elements (Na, K, Ca, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Cd, Sb, Ba, La, W, Au, Th) are determined. (orig.) [de

  3. Multielemental analysis of IAEA intercomparison standard Hay Powder, V-10 and some edible plant leaves by neutron activation. [Br,Ce,Cl,Cr,Cu,Fe,Ga,Hg,K,La,Mn,Mo,Na,P,Sc,Zn

    Energy Technology Data Exchange (ETDEWEB)

    Samudralwar, D L; Wankhade, H K; Garg, A N

    1987-12-01

    Instrumental neutron activation analysis was employed for the multielement determination of an IAEA intercomparison standard Hay Powder, V-10 and some edible plant leaves consumed in India. The samples were irradiated with thermal neutrons at a flux approx. = 10/sup 12/ n x cm/sup -2/ x s/sup -1/ in a reactor for 5 minutes, 1, 2, 5, 10 and 15 hours and counted by high resolution ..gamma..-ray spectrometry. Nearly 18 elements were determined. Good agreement is observed for most of the elements in several NBS standards and the proposed CRM V-10. Some edible vegetable plant leaves were also analyzed. (author) 32 refs.; 3 tabs.

  4. Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots

    Science.gov (United States)

    Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.

    2018-01-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.

  5. A low power x-ray tube for use in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kataria, S.K.; Govil, Rekha; Lal, M.

    1980-01-01

    A low power X-ray tube with thin molybdenum transmission target for use in energy dispersive X-ray fluorescence (ENDXRF) element analysis has been indigenously built, along with its power supply. The X-ray tube has been in operation since August 1979, and it has been operated upto maximum target voltage of 35 KV and tube current upto 200 μA which is more than sufficient for trace element analysis. This X-ray tube has been used alongwith the indigenously built Si(Li) detector X-ray spectrometer with an energy resolution of 200 eV at 5.9 Kev MnKsub(α) X-ray peak for ENDXRF analysis. A simple procedure of calibration has been developed for thin samples based on the cellulose diluted, thin multielement standard pellets. Analytical sensitivities of the order of a few p.p.m. have been obtained with the experimental setup for elements with 20 < = Z < = 38 and 60 < = Z < = 90. A number of X-ray spectra for samples of environmental, biological, agricultural, industrial and metallurgical interest are presented to demonstrate the salient features of the experimental sep up. (auth.)

  6. Evaluation of the applicability of the MOUDI impactor for aerosol collections with subsequent multielement analysis by PIXE

    International Nuclear Information System (INIS)

    Maenhaut, W.; Ducastel, G.; Hillamo, R.E.; Pakkanen, T.A.

    1993-01-01

    The micro-orifice uniform deposit impactor (MOUDI) is an 8-stage impactor with cut-sizes down to 0.056 μm and which allegedly provides uniform aerosol deposits for the various stages. In the present study it was examined how uniform the aerosol deposits really are for each impaction plate, and whether the uniformity is sufficient for a straightforward PIXE analysis. This was done by collecting several samples of ambient aerosol with the MOUDI and by determining the deposition pattern of various elements on the foils through a linear PIXE scan across each impaction foil. It was found that the deposits are far from uniform at the millimeter level for the stage numbers up to 6. Despite this, concentration data can easily be obtained by PIXE from such samples, provided that the analyzed area is carefully selected and appropriate correction factors for the nonuniformity are employed. Some size distribution data are presented. A comparison is also made of the size distribution data and detection limits that result from employing the MOUDI in combination with PIXE with those obtainable by PIXE analysis of some other types of cascade impactors. (orig.)

  7. A routine chromium determination in biological materials; application to various reference materials and standard reference materials

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Volkers, K.J.

    1979-01-01

    The determination limit under standard working conditions of chromium in biological materials is discussed. Neutron activation analysis and atomic spectrometry have been described for some analytical experiences with NBS SRM 1577 reference material. The chromium determination is a part of a larger multi-element scheme for the determination of 12 elements in biological materials

  8. The study of the trace element in organisms by neutron analysis. I. Multielement instrumental neutron activation analysis of cannabis

    International Nuclear Information System (INIS)

    Shinogi, M.; Murai, Y.; Mori, I.; Takeuchi, T.

    1977-05-01

    Examinations were made on optimal experimental conditions for instrumental determination of various elements in cannabis by neutron activation analysis, without any radiochemical separation, and the following conditions were found to be useful. Irradiation samples to be used are about 300 mg of the leaves or stem bark, and about 100 mg of the root. For soil sample, about 50 mg is used for the determination of short half-life nuclides and about 300 mg for long half-life nuclides. For short half-life nuclides, the samples are irradiated for 1 min, activity is measured for 200 sec after a decay of 3 min, and for 400 sec after a decay of 10 min. For long half-life nuclides, the samples are irradiated for 60 min and the activities are measured for 4 K sec after 1 week and for 10 K sec after 1 month. Use of supersonic waves is also convenient for cleansing of the samples. Thirty-five kinds of interesting elements were determined by this method from cannabis cultivated in Maizuru area. (Author)

  9. Study of the trace element in organisms by neutron activation analysis, 1. Multielement instrumental neutron activation analysis of cannabis

    Energy Technology Data Exchange (ETDEWEB)

    Shinogi, M; Murai, Y; Mori, I [Kobe Women' s Coll. of Pharmacy (Japan); Takeuchi, T

    1974-12-01

    Examinations were made on optimal experimental conditions for instrumental determination of various elements in cannabis by neutron activation analysis, without any radiochemical separation, and the following conditions were found to be useful. Irradiation samples to be used are about 300 mg of the leaves or stem bark, and about 100 mg of the root. For soil sample, about 50 mg is used for the determination of short half-life nuclides and about 300 mg for long half-life nuclides. For short half-life nuclides, the samples are irradiated for 1 min, activity is measured for 200 sec after a decay of 3 min, and for 400 sec after a decay of 10 min. For long half-life nuclides, the samples are irradiated for 60 min and the activites are measured for 4 K sec after 1 week and for 10 K sec after 1 month. Use of supersonic waves is also convenient for cleansing of the samples. Thirty-five kinds of interesting elements were determined by this method from cannabis cultivated in Maizuru area.

  10. Scaling of the flow field in a combustion chamber with a gas–gas injector

    International Nuclear Information System (INIS)

    Xiao-Wei, Wang; Guo-Biao, Cai; Ping, Jin

    2010-01-01

    The scaling of the flow field in a gas–gas combustion chamber is investigated theoretically, numerically and experimentally. To obtain the scaling criterion of the gas–gas combustion flowfield, formulation analysis of the three-dimensional (3D) Navier–Stokes equations for a gaseous multi-component mixing reaction flow is conducted and dimensional analysis on the gas–gas combustion phenomena is also carried out. The criterion implies that the size and the pressure of the gas–gas combustion chamber can be changed. Based on the criterion, multi-element injector chambers with different geometric sizes and at different chamber pressures ranging from 3 MPa to 20 MPa are numerically simulated. A multi-element injector chamber is designed and hot-fire tested at five chamber pressures from 1.64 MPa to 3.68 MPa. Wall temperature measurements are used to understand the similarity of combustion flowfields in the tests. The results have verified the similarities between combustion flowfields under different chamber pressures and geometries, with the criterion applied. (geophysics, astronomy and astrophysics)

  11. Hydrogeochemical and stream sediment reconnaissance of the National Uranium Resource Evaluation Program. Progress report, January--March 1978

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, T.A.; Bunker, M.E.; Hansel, J.M. Jr.

    1978-10-01

    The modifications to the Los Alamos Scientific Laboratory (LASL) Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) program, necessary to incorporate the expansion and revision of the overall HSSR program as required by the Department of Energy, have been completed. To date, approximately 57% of the total area assigned to the LASL in the Rocky Mountain region and Alaska has been sampled and plans are well under way to sample an additional 28% during FY 78. Contracts have been let to complete the sampling of the LASL area in the lower states and bids to sample an additional 33% of Alaska are being evaluated. Twenty reports (2 in press and 18 in preparation) are presently scheduled to be open filed within six months, reporting uranium data only for 18 complete quadrangles and multielement data for 11 complete quadrangles. In addition, data releases are being prepared to open file the uranium data from portions of 13 quadrangles that are now outside the LASL reporting boundary but which had been sampled by the LASL prior to the establishment of the new boundary in October 1977. By the end of the quarter, all multielement analysis systems were operational. Water samples from 7780 locations and sediment samples from 4170 locations were analyzed for uranium. Samples from approximately 6500 locations were analyzed by one or more of the multielement methods.

  12. Hydrogeochemical and stream sediment reconnaissance of the National Uranium Resource Evaluation Program. Progress report, January--March 1978

    International Nuclear Information System (INIS)

    Weaver, T.A.; Bunker, M.E.; Hansel, J.M. Jr.

    1978-10-01

    The modifications to the Los Alamos Scientific Laboratory (LASL) Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) program, necessary to incorporate the expansion and revision of the overall HSSR program as required by the Department of Energy, have been completed. To date, approximately 57% of the total area assigned to the LASL in the Rocky Mountain region and Alaska has been sampled and plans are well under way to sample an additional 28% during FY 78. Contracts have been let to complete the sampling of the LASL area in the lower states and bids to sample an additional 33% of Alaska are being evaluated. Twenty reports (2 in press and 18 in preparation) are presently scheduled to be open filed within six months, reporting uranium data only for 18 complete quadrangles and multielement data for 11 complete quadrangles. In addition, data releases are being prepared to open file the uranium data from portions of 13 quadrangles that are now outside the LASL reporting boundary but which had been sampled by the LASL prior to the establishment of the new boundary in October 1977. By the end of the quarter, all multielement analysis systems were operational. Water samples from 7780 locations and sediment samples from 4170 locations were analyzed for uranium. Samples from approximately 6500 locations were analyzed by one or more of the multielement methods

  13. Present status of neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Steinnes, E.

    1984-01-01

    Neutron activation analysis, in spite of its many advantageous features, is less widely used than some alternative trace element techniques, and has been losing ground during the last decade. In the environmental field however there are still many problems which can be solved in a better way by the contribution of NAA. The combination of multi-element capability and high accuracy is of great importance in many studies related to atmospheric trace elements. Also in aquatic studies NAA still has a significant role to play. Applications to soils, sediments, and plant material have so far been limited, but there is a place for further development. The scope of NAA in environmental research may be extended by further use of pre-irradiation separations. NAA is particularly important in the certification of analytical reference materials in the environmental field. In future applications of NAA an appropriate combination with other analytical techniques will often be a requisite for success. The general future of NAA is dependent on the availability of nuclear reactors, radiochemical laboratoties and appropriate competence. 21 references

  14. Determination of trace elements in seawater by neutron activation analysis and electrochemical separation

    International Nuclear Information System (INIS)

    Jorstad, K.; Salbu, B.

    1980-01-01

    The combination of neutron activation analysis and electrolysis at a constant, controlled potential has proved itself to be a useful multielement method for the determination of 28 elements in seawater. After freeze-drying and irradiation, the samples are dissolved and electrolyzed for 1 h. The radioactive species deposited on the mercury cathode allow determination of 14 elements (Ag, As, Au, Cd, Co, Cr, Fe, Ga, Hg, La, Mo, Sb, Se, Zn). Another 14 elements (Ba, Br, Ca, Ce, Cs, Eu, Na, Rb, Sc, Sm, Sr, Th, U, Yb) are quantitatively determined by measuring the activities in the residual solution. To obtain a reproducible electrolysis, radioactive tracers have been used to study the decrease of element concentrations in solution as a function of time of electrolysis, the influence of the initial element concentration on the rate constant k, the effect of cathode material and of the pH in the solution. 4 figures, 4 tables

  15. Integrated Process Design, Control and Analysis of Intensified Chemical Processes

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil

    chemical processes; for example, intensified processes such as reactive distillation. Most importantly, it identifies and eliminates potentially promising design alternatives that may have controllability problems later. To date, a number of methodologies have been proposed and applied on various problems......, that the same principles that apply to a binary non-reactive compound system are valid also for a binary-element or a multi-element system. Therefore, it is advantageous to employ the element based method for multicomponent reaction-separation systems. It is shown that the same design-control principles...

  16. Applications of X-ray emission to elemental analysis of foods

    International Nuclear Information System (INIS)

    Flocchini, R.G.; Lagunas-Solar, M.C.; Perley, B.P.

    1996-01-01

    Trace element analysis via X-Ray Fluorescence (XRF) and Proton-Induced X-Ray Emission (PIXE) techniques were applied to several samples of fresh and processed foods. Thin samples of fresh fruits and vegetables, processed dry foods, and spices were included in these analyses. The results indicate that XRF and/or PIXE analysis is applicable to these types of samples but require special and simple modifications in sample preparation techniques, and the inclusion of new matrix type corrections for data analysis. However, the non-destructive nature, reproducibility, efficiency and high sensitivity that characterize these multi-element analytical procedures can provide new potential methods for detecting trace elements in foods and in many agricultural commodities. Toxic metals such as Hg, Pb, and As were detected in some foods. In addition, other essential or neutral trace elements such as Na, K, Mg, Ca, Cu, Cr, V, Zn, Mo, Fe, Mn, Ni, Se, Cl, S, and P were also detected. These and other elements can be analyzed rapidly and with high sensitivity for applications in process control and for certification of food quality. Developing these techniques and procedures specifically for food and for various agricultural products may provide new analytical options and help mitigate the expected impact of forthcoming regulations intended to establish limits and tolerance levels for micro toxicants and other essential nutrients in foods and agricultural products. (author)

  17. Activation analytical determination of essential and toxic trace elements in biological material

    International Nuclear Information System (INIS)

    Schelenz, R.

    1980-01-01

    In order to determine the essential trace elements Hg, Ag, Cu and Se in food (potatoes, milk powder) and biological standard materials (fruit tree leaves), simple, fast radiochemical separation methods are worked out. Following oxidative decomposition and destillation of Hg, the elements silver, copper and selenium are found in the destillation residue and can be electrochemically enriched on an amalgamated Cu foil (determination of Ag and Se in the concentration range of 10 -9 to 10 -8 g, of Cu in the range of 10 -12 to 10 -10 g), whilst the matrix elements Na, K, P are adsorbed on a column with 3 different inorganic ion exchangers. The eluate of the ion exchanger can be added directly to the multielement gamma spectroscopy. The possiblity of working purely instrumentally is demonstrated by 2 examples: multielement analysis of human hair and river water. (RB) [de

  18. The effectiveness of various treatments in changing the nutrient status and bioavailability of risk elements in multi-element contaminated soil.

    Science.gov (United States)

    García-Sánchez, Mercedes; García-Romera, Inmaculada; Száková, Jiřina; Kaplan, Lukáš; Tlustoš, Pavel

    2015-09-01

    Potential changes in the mobility and bioavailability of risk and essential macro- and micro-elements achieved by adding various ameliorative materials were evaluated in a model pot experiment. Spring wheat (Triticum aestivum L.) was cultivated under controlled condition for 60 days in two soils, uncontaminated Chernozem and multi-element contaminated Fluvisol containing 4900 ± 200 mg/kg Zn, 35.4 ± 3.6 mg/kg Cd, and 3035 ± 26 mg/kg Pb. The treatments were all contained the same amount of sulfur and were as follows: (i) digestate from the anaerobic fermentation of biowaste, (ii) fly ash from wood chip combustion, and (iii) ammonium sulfate. Macro- and micro-nutrients Ca, Mg, K, Fe, Mn, Cu, P, and S, and risk elements Cd, Cr, Pb, and Zn were assayed in soil extracts with 0.11 mol/l solution of CH3COOH and in roots, shoots, and grain of wheat after 30 and 60 days of cultivation. Both digestate and fly ash increased levels of macro- and micro-nutrients as well as risk elements (especially Cd and Zn; the mobility of Pb decreased after 30 days of cultivation). The changes in element mobility in ammonium sulfate-treated soils appear to be due to both changes in soil pH level and inter-element interactions. Ammonium sulfate tended to be the most effective measure for increasing nutrient uptake by plants in Chernozem but with opposite pattern in Fluvisol. Changes in plant yield and element uptake in treated plants may have been associated with the higher proline content of wheat shoots cultivated in both soils compared to control. None of the treatments decreased uptake of risk elements by wheat plants in the extremely contaminated Fluvisol, and their accumulation in wheat grains significantly exceeded maximum permissible levels; these treatments cannot be used to enable cereal and other crop production in such soils. However, the combination of increased plant growth alongside unchanged element content in plant biomass in pots treated with digestate

  19. Analysis of Angolan human hair samples by the k0-NAA technique on the Dalat research reactor

    International Nuclear Information System (INIS)

    Lemos, P.C.D; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Mong Sinh

    2006-01-01

    There is personal difference in concentrations of trace elements in the human hair according to human life or history such as occupation, sex, age, food, habit, social condition and so on. It is also found that the individual's deviation of elemental concentrations reflecting the degree of environmental pollutants exposure to the human body, intakes of food and metabolism. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on research reactor has been recommended by WHO and IAEA as a main analytical technique with the advantages of sensitivity, precision, accuracy, multi-element and routine. This report presents the results of determination of about 20 elements in 23 human hair samples, which have been collected from different places in Angola by using k 0 -NAA technique on Dalat nuclear research reactor. Accuracy of the method was ascertained by analysis of two human hair certified reference materials (CRMs), i.e. NIES-5 and GBW-09101 and assessed by the deviation of experiment to certified values generally within 10% and U-score values mostly lower 2. (author)

  20. Nuclear techniques for in situ evaluation of coal and mineral deposits

    International Nuclear Information System (INIS)

    Borsaru, M.

    1993-01-01

    This paper reviews developments in in situ analysis of minerals and coal by nuclear borehole logging. Developments in the oil, gas and uranium industries are not discussed in the present paper unless they have direct applications in the mineral industry (e.g. multi-element analysis and development of spectral litho-density tools). The review covers techniques developed mostly in the last decade and is based on work published in North America, Europe and Australia. (author)

  1. Elemental analysis of sub-hourly ambient aerosol collections

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, C.B.; Ondov, J.M. [University of Maryland, College Park, MD (USA). Dept. of Chemical & Biochemistry

    2004-03-01

    Simultaneous multielement graphite furnace atomic absorption spectrometry was used to determine Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Se, and Zn in ambient air sampled at 170 L.min{sup -1} for 30 min and collected as a slurry after dynamic preconcentration. Analyses of slurries of NIST SRM 1648, Urban Particulate Matter, were typically within 10% of expected values for all elements except Al, Cr, and Fe, elements for which deviations were mostly due to difficulties in transferring large particles. This problem will be reduced for urban fine particulate matter samples (PM2.5). Trends in the concentrations of elemental source markers were readily correlated with wind direction and other meteorological factors to identify the influences of local industrial emissions, including motor vehicle traffic, coal- and oil-fired power plants, and municipal incinerators. Factor analysis was applied to the 88-sample data set to extract 7 factors: urban dust, meteorological factors, incinerators, coal- fired power plants, Tour Bus emission, unknown As source, and oil-fired power plants. Factor analysis was also applied to an 18-sample data set representing 2.5 h averages of the 30 min data to simulate the effect of longer sample collection times. Only 6 factors were extracted from this data set, which shows that increased temporal resolution enhances the power of factor analysis to resolve sources. These results indicate that a wealth of detailed information is revealed at this level of temporal resolution.

  2. Improvements of neutron activation techniques for the determination of fissile material concentrations

    International Nuclear Information System (INIS)

    Papadopoulos, N.N.

    1987-01-01

    Certain experimental improvements, as variable sample size and irradiation position, automation and flexibility in radiation detection, broaden the measurable concentration range, increase the possible rate and accuracy of analysis and enlarge the application range of home-made nuclear analyzer for fissile material analysis by delayed fission neutron counting and for short-lived multielement analysis by neutron activation gamma-ray spectrometry. Intercomparisons of results by various methods and laboratories show the need for regular checks of techniques to ensure reliable measurements. (author)

  3. Neutron-induced prompt gamma-ray analysis of Gulf marine environmental samples

    International Nuclear Information System (INIS)

    Yonezawa, C.; Matsue, H.; Adachi, T.; Hoshi, M.; Tachikawa, E.; Povinec, P.P.; Fowler, S.W.; Baxter, M.S.

    1999-01-01

    Multi-element composition and isotopic characteristics of the oil and contaminated materials, and measurement of historical records of marine environmental condition using annual bands in coral samples have been investigated in the program. Elemental analyses have been carried out by the PGA together with INAA and ICP-MS to obtain accurate and precise elemental characteristics of oil, marine sediment and bivalves. Fifteen elements including light elements of H, B, N, Si and Ca which cannot be determined by INAA and ICP-MS, were determined by the PGA. Altogether 43 elements were determined

  4. Soil pH and nutrient uptake in cauliflower (Brassica oleracea L. var. botrytis) and Broccoli (Brassica oleracea L. var. italica) in Northern Sweden. Multielement studies by means of plant and soil analyses

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, Margareta [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Agricultural Research for Northern Sweden

    2000-07-01

    To reveal nutrient element deficiencies or imbalances limiting vegetable production in northern Sweden, multielement soil and plant analyses were performed in cauliflower and broccoli during the period 1989 to 1996. The pH range of the soils was 4.4-8. 1. The results were evaluated with the multivariate statistical methods PCA (Principal Component Analysis) and PLS (Partial Least Squares Projection to Latent Structures). The major yield-limiting elements were Mg, B, Mn, Zn, Fe and Cu. This was a result of high soil pH and large content of Ca in the soil. The reason for B deficiency was also low B content in the soil. Applications of green mulch increased yield on soils with a pH below 6.0. It also increased the uptake and concentration in the plants of B, Ba, Cl, Cu, K, Mg, Mn, N, P, Se and Zn, and decreased the uptake and concentration of Al, Cs and Tl. The mineral fertilizer applied, NPK 11-5-18 micro, decreased soil pH. This has resulted in larger uptake and higher concentrations in the plants of Co and Mn, in comparison to where cattle manure was applied. This fertilizer strongly decreased uptake of Mo, as a result of both the acidifying effect and the large S content. Repeated applications of nitrate of lime in combination with the NPK 11-5-18 strongly increased the uptake of Cs by the plants. The results in this investigation, together with the literature reviews, strongly indicate that a relatively low soil pH (5.0-5.5) is favourable when organic fertilizers are used and that harmful effects of very low soil pH (<5.0), are ameliorated by organic materials but aggravated by mineral fertilizers. The main purpose of lime is to counteract the acidity and increased leaching created by mineral fertilizers. Because of the historical context in which the lime requirements were established, the dangers of acid soils appear to have been strongly overestimated.

  5. Ferrous analysis

    International Nuclear Information System (INIS)

    Straub, W.A.

    1987-01-01

    This review is the seventh in the series compiled by using the Dialog on-line CA Search facilities at the Information Resource Center of USS Technical Center covering the period from Oct. 1984 to Nov. 1, 1986. The quest for better surface properties, through the application of various electrochemical and other coating techniques, seems to have increased and reinforces the notion that only through the value added to a steel by proper finishing steps can a major supplier hope to compete profitably. The detection, determination, and control of microalloying constituents has also been generating a lot of interest as evidenced by the number of publications devoted to this subject in the last few years. Several recent review articles amplify on the recent trends in the application of modern analytical technology to steelmaking. Another review has been devoted to the determination of trace elements and the simultaneous determination of elements in metals by mass spectrometry, atomic absorption spectrometry, and multielement emission spectrometry. Problems associated with the analysis of electroplating wastewaters have been reviewed in a recent publication that has described the use of various spectrophotometric methods for this purpose. The collection and treatment of analytical data in the modern steel making environment have been extensively reviewed emphasis on the interaction of the providers and users of the analytical data, its quality, and the cost of its collection. Raw material treatment and beneficiation was the dominant theme

  6. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1995-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques. (author) 7 refs.; 5 tabs

  7. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    International Nuclear Information System (INIS)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves

    2017-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2 k experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2 3 and the 2 4 , depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  8. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  9. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves, E-mail: uandapaula@gmail.com, E-mail: emoreira@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2{sup k} experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2{sup 3} and the 2{sup 4}, depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  10. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  11. Trace element analysis with PIXE using Trombay 5.5 MeV Van de Graaff accelerator

    International Nuclear Information System (INIS)

    Govil, Rekha; Kataria, S.K.; Kapoor, S.S.; Madan Lal; Nadkarni, D.M.; Rama Rao, P.N.; Viswanathan, K.V.

    1980-01-01

    The work on trace element analysis using proton induced X-ray emission technique (PIXE) with the proton beam from 5.5 MeV Van de Graaff accelerator at Trombay, is described. The experimental set up consisted of an indigeneously built 220 eV resolution Si(Li) x-ray spectrometer and target chamber having arrangements to mount upto twelve targets. In the present work, a variety of samples of biological nature, monazite mineral and some other samples were analyzed along with a standard multi-element sample. The sample preparation technique for different samples is also given in the report. For quantitative estimation of trace elements, a computer code developed earlier was used. The proton induced x-ray spectra of various samples and their computer fits are presented and quantitative results for some selected samples are also given. The minimum detection limits which were achieved with the present set up are also given. (auth.)

  12. Some considerations for future instrumentation and software in N.A.A

    International Nuclear Information System (INIS)

    Bruin, M. de; Korthoven, P.J.M.; Houtman, J.P.W.

    1976-09-01

    This paper deals with the optimization of known techniques and equipment in neutron activation analysis, specifically dealing with simple and rapid multi-element analysis. It points to the need for improvement either of precision and accuracy without an appreciable increase in analysis costs, or for a decrease in the costs per analysis without affecting precision and accuracy. Specifically it deals with well-type Ge(Li)-detectors and low-energy photon detectors (keV range) coupled with a computer to correct automatically for self-absorption without a priori knowledge of sample composition

  13. Final results of the FY'78 chemistry and materials science research program review

    International Nuclear Information System (INIS)

    Frazer, J.W.

    1977-01-01

    18 projects which were selected to be sponsored by ''Chemistry Research Program'' are summarized. These include: lasers for chemical analysis; multi-element analysis systems; spectroscopic analysis of surface passivation; non-aqueous titrimetry; materials damage prediction for fiber composites; safe high energy explosives; single photon absorption reaction chemistry; reaction in shock waves; cryogenic heavy hydrogen technology; acoustic emission; metallic alloy glasses; basic study of toughness in steel; static equation-of-state at 100 GPa; transuranium element research; nuclear structure research; neutron capture gamma measurements; x-ray fluorescence analysis; and pyrochemical investigation

  14. Fundamentals of multi-element analysis with electron and beta radiation. 4

    International Nuclear Information System (INIS)

    Thuemmel, H.W.; Koerner, G.; Apel, K.

    1977-01-01

    Mass attenuation coefficients of liquid hydrocarbons and their oxygen, nitrogen and halogen derivates have been measured and compared with the values obtained according to the various calculation instructions (see pt.3). Using the most complete formula according to Schmidt the values obtained are systematically too low (up to 5 per cent), even with best parameter values. Only about half the values deviate by less than 3 per cent. Though the maximum deviations of 5 per cent are beyond the experimental errors (<= +-1 per cent) and the errors introduced by adaption of the general function to the mass attenuation coefficients of elementary absorbers (<= +-2.5 per cent), certain systematic deviation patterns (< 2.5 per cent) can be observed only for individual homologous series (alkanes, benzene derivatives), which may be caused by bonding effects or by remaining shortcomings of the model. The simple formula μsub(Σ) = Σpsub(i)μsub(i) provides effective mass attenuation coefficients, the error of which is up to 10 per cent. (author)

  15. Fundamentals of multi-element analysis with electron and beta radiation. 3

    International Nuclear Information System (INIS)

    Thuemmel, H.W.

    1977-01-01

    Mass attenuation coefficients obtained from calculations with the empirical formula μsub(Σ) = Σ psub(i).μsub(i) have been compared with the theoretical Schmidt formula (1906), in which the effective mass attenuation coefficient μsub(th) of a mixture of substances is the product of a true effective mass attenuation coefficient μ 0 and an effective by-pass coefficient U. Numerical results obtained from many substances of strongly varying composition show that for mixtures of components with atomic numbers Zsub(i) differing not too much from each other (contents psub(i), mass attenuation coefficients μsub(i) μ(Zsub(i)) μsub(Σ) is an approximation of μsub(th). This limitation is the less important, the less the curvature of the dependence of the mass attenuation coefficients of all elements on the atomic number (author)

  16. Determination of geographic provenance of cotton fibres using multi-isotope profiles and multivariate statistical analysis

    Science.gov (United States)

    Daeid, N. Nic; Meier-Augenstein, W.; Kemp, H. F.

    2012-04-01

    The analysis of cotton fibres can be particularly challenging within a forensic science context where discrimination of one fibre from another is of importance. Normally cotton fibre analysis examines the morphological structure of the recovered material and compares this with that of a known fibre from a particular source of interest. However, the conventional microscopic and chemical analysis of fibres and any associated dyes is generally unsuccessful because of the similar morphology of the fibres. Analysis of the dyes which may have been applied to the cotton fibre can also be undertaken though this can be difficult and unproductive in terms of discriminating one fibre from another. In the study presented here we have explored the potential for Isotope Ratio Mass Spectrometry (IRMS) to be utilised as an additional tool for cotton fibre analysis in an attempt to reveal further discriminatory information. This work has concentrated on un-dyed cotton fibres of known origin in order to expose the potential of the analytical technique. We report the results of a pilot study aimed at testing the hypothesis that multi-element stable isotope analysis of cotton fibres in conjunction with multivariate statistical analysis of the resulting isotopic abundance data using well established chemometric techniques permits sample provenancing based on the determination of where the cotton was grown and as such will facilitate sample discrimination. To date there is no recorded literature of this type of application of IRMS to cotton samples, which may be of forensic science relevance.

  17. Underlying role of mechanical rigidity and topological constraints in physical sputtering and reactive ion etching of amorphous materials

    Science.gov (United States)

    Bhattarai, Gyanendra; Dhungana, Shailesh; Nordell, Bradley J.; Caruso, Anthony N.; Paquette, Michelle M.; Lanford, William A.; King, Sean W.

    2018-05-01

    Analytical expressions describing ion-induced sputter or etch processes generally relate the sputter yield to the surface atomic binding energy (Usb) for the target material. While straightforward to measure for the crystalline elemental solids, Usb is more complicated to establish for amorphous and multielement materials due to composition-driven variations and incongruent sublimation. In this regard, we show that for amorphous multielement materials, the ion-driven yield can instead be better understood via a consideration of mechanical rigidity and network topology. We first demonstrate a direct relationship between Usb, bulk modulus, and ion sputter yield for the elements, and then subsequently prove our hypothesis for amorphous multielement compounds by demonstrating that the same relationships exist between the reactive ion etch (RIE) rate and nanoindentation Young's modulus for a series of a -Si Nx :H and a -Si OxCy :H thin films. The impact of network topology is further revealed via application of the Phillips-Thorpe theory of topological constraints, which directly relates the Young's modulus to the mean atomic coordination () for an amorphous solid. The combined analysis allows the trends and plateaus in the RIE rate to be ultimately reinterpreted in terms of the atomic structure of the target material through a consideration of . These findings establish the important underlying role of mechanical rigidity and network topology in ion-solid interactions and provide additional considerations for the design and optimization of radiation-hard materials in nuclear and outer space environments.

  18. Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

    Energy Technology Data Exchange (ETDEWEB)

    Pavlish, John; Thompson, Jeffrey; Dunham, Grant

    2014-09-30

    Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels

  19. Electrostatic afocal-zoom lens design using computer optimization technique

    Energy Technology Data Exchange (ETDEWEB)

    Sise, Omer, E-mail: omersise@gmail.com

    2014-12-15

    Highlights: • We describe the detailed design of a five-element electrostatic afocal-zoom lens. • The simplex optimization is used to optimize lens voltages. • The method can be applied to multi-element electrostatic lenses. - Abstract: Electron optics is the key to the successful operation of electron collision experiments where well designed electrostatic lenses are needed to drive electron beam before and after the collision. In this work, the imaging properties and aberration analysis of an electrostatic afocal-zoom lens design were investigated using a computer optimization technique. We have found a whole new range of voltage combinations that has gone unnoticed until now. A full range of voltage ratios and spherical and chromatic aberration coefficients were systematically analyzed with a range of magnifications between 0.3 and 3.2. The grid-shadow evaluation was also employed to show the effect of spherical aberration. The technique is found to be useful for searching the optimal configuration in a multi-element lens system.

  20. Multi-element measurements in mexican cigarette tobacco

    International Nuclear Information System (INIS)

    Vega-Carrillo, H.R.; Texas Univ., Austin, TX; Zacatecas Univ.; Iskander, F.Y.; Manzanares-Acuna, E.

    1995-01-01

    The concentration of 21 elements in cigarette tobacco in nine different brands manufactured and commercially available in Mexico has been determined using neutron activation analysis. The concentration range of the measured elements (in μg g -1 ) were: As, (four brands) <0.55-3.24; Ba, 64-251; Br, (four brands) 49-136; Ce, <0.3-1.7; Co, 0.29-0.55, Cr, <0.8-2.4; Cs, 0.091-0.40; Eu, <0.03; Fe, 420-680; Hf, <0.03-0.13; K, (four brands) 18300-40300; La, (four brands) < 0.2-0.66; Na, (four brands) 309-566; Rb, 19-50; Sb, <0.7; Sc, 0.13-0.22; Se, <0.7; Sm, (four brands) 0.07-0.14; Sr, 227-472; Th, < 0.1-0.17 and Zn, 14-56. The results are compared with the literature values for the concentration of the above elements in cigarette tobacco from other countries. (author) 18 refs.; 2 tabs

  1. Quality in the chemical analysis of biological matrices by fluorescence X-ray by energy dispersive

    International Nuclear Information System (INIS)

    Sousa, Evely E. de; Paiva, Jose Daniel S. de; Franca, Elvis J. de; Almeida, Macio E.S.; Cantinha, Rebeca S.; Hazin, Clovis A.

    2013-01-01

    The aim of this study was to obtain multielement analytical curves of high analytical rigor to the analysis of biological matrices by the technique of fluorescence x-ray energy dispersive - EDXRF. Calibration curves were constructed from the reference materials IAEA 140, IAEA 155, IAEA V8, V10 to the International Atomic Energy Agency - IAEA, and SRM1515, SRM 1547, SRM 1570a, SRM 1573a, SEM 1567a, to the National Institute of Standards and Technology - NIST. After energy calibration, all samples were subjected to vacuum to the analyzes by 100 seconds for each group of chemical elements. The voltages used were respectively 15 keV for chemical elements with less than atomic number 22 and 50 keV for the others. After the construction of the curves, the analytical quality was assessed by the analysis of a portion-test of the reference material SRM 2976, also produced by NIST. Based on the number of certified reference materials used for construction of calibration curves in this work, quality analytical protocol was originated with considerable reliability for quantification of chemical elements in biological samples by EDXR

  2. Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multielement analysis of geothermal waters

    International Nuclear Information System (INIS)

    Blommaert, W.; Vandelannoote, R.; Van't Dack, L.; Gijbels, R.; Van Grieken, R.

    1980-01-01

    To sulfide geothermal waters from the French Pyrenees region and bicarbonate and chloride waters from the French Vosges area, all of the following analysis techniques were applied in order to compose a broad inventory of trace elements: (1) for the dissolved metarial: neutron activation analysis after a freeze-drying step using a very short cycle, short cycle or long cycle, neutron activation after co-crystallization on 1-(2-pyridylazo)-2-naphthol (PAN) using a short cycle or long cycle, X-ray fluorescence after co-crystallization on PAN and spark source mass spectrometry after evaporation on graphite or preconcentration on PAN, and, (2) for the filtered or suspended material: neutron activation using a very short, short or long cycle and X-ray fluorescence. Altogether, on the average some 30 elements could be determined above the detection limit in solution and 15 in suspension. (author)

  3. [Simultaneous determination of multiple elements in airborne particulate samples by X-ray fluorescence spectrometry].

    Science.gov (United States)

    Takada, T; Hitosugi, M; Kadowaki, T; Kudo, M

    1983-07-01

    An energy dispersive X-ray fluorescence spectrometer (EDX) has been applied to determine multielements in the workplace air. The standards for X-ray fluorescence analysis were prepared by the chelate precipitation method on polyvinyl chloride (PVC) membrane filter. And, the specimens were prepared to deposit various metal compounds of different chemical forms by the suspension method on PVC membrane filter, and they were determined with EDX and atomic absorption spectrometer (AAS). The results obtained were as follows. Though there is a difference by each element, an amount less than 3 microgram/cm2 per unit area makes it possible to undergo multielement analysis, that is, is has no influence on fine particle effect (particle size; under 5 microns). Then, effects of the X-ray intensity by different chemical forms are negligible. At the presence the neighboring element and other elements this technique showed greater precision by carrying out on corrective treatment, etc. The coefficient of variation of this technique was in the range of 2.5-6.5% at DDTC-Cu of 0.5-5.0 micrograms/cm2, with the limit of detection for As : 0.002 microgram/cm2, Zn : 0.003 microgram/cm2, Pb : 0.003 microgram/cm2, Cu : 0.004 microgram/cm2, Ni : 0.003 microgram/cm2, Fe : 0.005 microgram/cm2, Mn : 0.008 microgram/cm2, Cr : 0.013 microgram/cm2, respectively. Aerosols collected at the workplace were analyzed with EDX and AAS, and the obtained results showed good agreement with such regression line as y = 1.04 chi + 0.04, the coefficient of correlation being r = 0.995. From these results, this technique was found to be a very excellent method for monitoring of multielements in the workplace air.

  4. Comparative study of destructive and non-destructive methods in the activation analysis of rocks

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.

    1978-01-01

    A comparative study between non-destructive thermal neutron activation analysis and activation analysis with radiochemical group separation is made Both methods are applied to the determination of trace elements minor and major elements in rocks. The treatment of the rocks, with special reference to the problems related to grinding and contamination by foreign elements is described. The choice of standards for multielement trace activation analysis is discussed. Two types of computer programs for the evalution of data obtained through Ge-li detector counting are used. All the phases of the destructive and non destructive analysis are described. In the destructive analysis, an adaptation of the group separation scheme developed by Morrison et al for the activation analysis of geological samples is made. The changes introduced make the radiochemical separation simpler and more rapid. Both destructive and non destructive methods are tested by means of the analysis of the United States Geological Survey standard rock AGV-1, which has been analysed by many authors. The same procedure is then applied to some alcaline rocks taken from the apatite mine of Jacupiranga, in the State of Sao Paulo, Brazil. The knowledge of the trace element concentration in these rocks is important for geochemical studies. A detailed study of the possible interferences encountered in the neutron activation analysis of these rocks is made, considering the interferences due to major activities, and to the proximity of the several gamma ray energies of the radioisotopes produced. Finally, the comparative study between the two methods is presented, using statistical tests for the quantitative evalution of results. (Author) [pt

  5. Authentication of organically grown plants - advantages and limitations of atomic spectroscopy for multi-element and stable isotope analysis

    DEFF Research Database (Denmark)

    Laursen, Kristian Holst; Schjørring, Jan Kofod; Kelly, S.D.

    2014-01-01

    Organic food products are believed to be healthier, safer and more environment-friendly than their conventional counterparts and are sold at premium prices. Consequently, adulteration of organic plants and fraudulent activities for economic profit are increasing. This has spurred the development...... plant tissue, and compound-specific isotope analysis based on isotope ratio-mass spectrometry are promising tools for documenting the fertilization history of organic plants. However, these techniques are challenged by the potential diversity of fertilization practices of organic and conventional plant...

  6. Investigation of the 107Cd and 115Cd decay schemes and their application in neutron activation analysis

    International Nuclear Information System (INIS)

    Taha, M.

    1980-01-01

    The γ-decay of 107 Cd and 115 Cd was measured with a Ge(Li)-detector. In addition to improvements of the data of known transitions several transitions have been verified (sup(115m)Cd: 1074.18, 1596.18 keV, 107 Cd: 1142.47 keV). Some γ-lines were observed for the first time (sup(115m)Cd: 132.88, 1071.01, 1239.61 keV, 107 Cd: 132.62, 185.70, 474.56 keV). The results are interpreted by means of nuclear models. A k = 1/2-rotations band is verified by adding the 1071 and 1239 keV-states in the level scheme of 115 In. The multielement activation analysis was used for the detection of Cd traces in birch trees, which were taken from different environments. Evidence was found for the assumption that the Cd was taken up from the soil and enriched by the trees. (orig.)

  7. Quantitative determination of α and f parameters for κo NAA

    International Nuclear Information System (INIS)

    Moon, J. H.; Kim, S. H.; Jeong, Y. S.

    2002-01-01

    Instrumental Neutron Activation Analysis as a representative method of nuclear analytical techniques, has advantages of non-destructive, simultaneous multi-element analysis with the characteristics of absolute measurement. Recently, use of κ o quantitative method which is accurate, convenient and user-friendly has been generalized world-widely. In this study, α and f parameters which is indispensable to implement κ o NAA were experimentally measured at NAA No.1-irradiation hole of HANARO research reactor. In addition, it was intended to apply routine analysis by the establishment of reliable and effective procedure of the measurement

  8. Inductively-coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Dale, L.

    1990-01-01

    The instrument in operation at the Lucas Heights Research Laboratories is a VG Plasma-quad PQ 2. A schematic diagram of the instrument components is presented along with its applicability to various fields of research and its perceived limitations. Apart from its high sensitivity the capability for rapid multi-element analysis in one of its major advantages over other instrumental method analysis. The necessity to present the sample in the form of a solution is probably its major drawback. 4 tabs, 7 figs

  9. Nondestructive testing: Neutron radiography and neutron activation. (Latest citations from the INSPEC: Information services for the physics and engineering communities database). Published Search

    International Nuclear Information System (INIS)

    1993-08-01

    The bibliography contains citations concerning the technology of neutron radiography and neutron activation for nondestructive testing of materials. The development and evaluation of neutron activation analysis and neutron diffraction examination of liquids and solids are presented. Citations also discuss nondestructive assay, verification, evaluation, and multielement analysis of biomedical, environmental, industrial, and geological materials. Nondestructive identification of chemical agents, explosives, weapons, and drugs in sealed containers are explored. (Contains a minimum of 83 citations and includes a subject term index and title list.)

  10. FY 1997 report on the study on lamination control technology for functional multi-element oxide thin films by complex beam epitaxy (CxBE) process; 1997 nendo chosa hokokusho (sakutaisen epitaxy (CxBE) ho ni yoru kinosei tagenso sankabutsu usumaku no sekiso seigyo gijutsu ni kansuru kenkyu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Complex beam epitaxy (CxBE) process was proposed and demonstrated as new deposition process of multi-element oxide thin films. This process radiates excimer laser onto a metal complex target of ethylenediamine-tetraacetate complex under reduced pressure oxygen atmosphere condition in a reaction vessel to supply raw material onto a heated substrate. This process allowed deposition of YBCO123 phase hetero-epitaxial film onto a single-crystalline SrTiO3 substrate. This process was proved to be promising through study on crystal orientation, composition transcription and surface smoothness of the obtained oxide thin films. In addition, epitaxial ZnO film was also deposited onto a single crystalline Al2O3 substrate by this process. The relation between the obtained film and substrate epitaxy was examined, and photoluminescence of specimens was measured by triple wave of Nd:YAG laser. As a result, it was clarified that the epitaxial ZnO film prepared by this process is useful as laser material. 60 refs., 48 figs., 5 tabs.

  11. Role of neutron activation analysis in metrology of modern inorganic trace analysis. Pt.3: NAA in characterization of sampling behavior for multielements

    International Nuclear Information System (INIS)

    Tian Weizhi; Ni Bangfa; Wang Pingsheng; Chen Xilin; Huang Donghui; Zhang Guiying; Zhang Lanzhi; Liu Cunxiong; Liu Likun

    2005-01-01

    The necessity of the development of new generation of certified reference materials (CEMs) and the role that NAA will play in the certification of those CRMs are discussed. In conclusion, the major role of NAA in the metrology of contemporary inorganic trace analysis is summarized: the international recognition of NAA as a primary ratio method will imply a major contribution to the improvement of CEMs: the concurrent use of k 0 -NAA will further strengthen the position of relative NAA as a primary ratio method; and NAA will play an irreplaceable role in the creation of new generation of CRMs, that will eventually lead the establishment of quality control system for microanalysis. (authors)

  12. Multielement analysis of X-Ray fluorescence of Nerium oleander L. Leaves in metropolitan region of Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Ramon S.; Sanches, Francis Anna C.R.A.; Neves, Arthur O.P.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: arthur.nevess@yahoo.com.br, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Some plants are used in the detection of the air pollutants due to leaves ability to absorb the pollutants through their stomata and the cuticle, thus, the plants leaves work as a natural sample of the air emissions that are deposited in their self. However, the foliar analysis of these vegetal species can be used to environmental monitoring. The Nerium oleander L. is a specie of plant commonly used as an environmental biomonitor. In this study, Nerium oleander L. leaves were used as biomonitors to evaluate the levels of environmental pollutants in a sub-region in the Metropolitan Region of Rio de Janeiro-Brazil through Energy Dispersive X-ray Fluorescence technique - EDXRF. The EDXRF system was developed in the own laboratory and consist of a portable XRF system formed by a mini X-ray tube of low power (anode of Ag and operated in 15 kV/50 μA and 35 kV/50 μA) and a SiPIN detector. Samples of Nerium oleander L. were collected from adult plants drawn randomly so as not favoring one side of the plant. The samples were collected during the year seasons (summer and winter). It was detected the concentration of 13 elements: S, Cl, K, Ca, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb, and obtain elemental maps of the regions of study. The study shows that the use of EDXRF technique associated to the Nerium oleander L. leaves used as biomonitor is an efficient, precise, fast and low-cost option for air pollutants analysis. (author)

  13. Multielement analysis of X-Ray fluorescence of Nerium oleander L. Leaves in metropolitan region of Rio de Janeiro

    International Nuclear Information System (INIS)

    Santos, Ramon S.; Sanches, Francis Anna C.R.A.; Neves, Arthur O.P.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Some plants are used in the detection of the air pollutants due to leaves ability to absorb the pollutants through their stomata and the cuticle, thus, the plants leaves work as a natural sample of the air emissions that are deposited in their self. However, the foliar analysis of these vegetal species can be used to environmental monitoring. The Nerium oleander L. is a specie of plant commonly used as an environmental biomonitor. In this study, Nerium oleander L. leaves were used as biomonitors to evaluate the levels of environmental pollutants in a sub-region in the Metropolitan Region of Rio de Janeiro-Brazil through Energy Dispersive X-ray Fluorescence technique - EDXRF. The EDXRF system was developed in the own laboratory and consist of a portable XRF system formed by a mini X-ray tube of low power (anode of Ag and operated in 15 kV/50 μA and 35 kV/50 μA) and a SiPIN detector. Samples of Nerium oleander L. were collected from adult plants drawn randomly so as not favoring one side of the plant. The samples were collected during the year seasons (summer and winter). It was detected the concentration of 13 elements: S, Cl, K, Ca, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb, and obtain elemental maps of the regions of study. The study shows that the use of EDXRF technique associated to the Nerium oleander L. leaves used as biomonitor is an efficient, precise, fast and low-cost option for air pollutants analysis. (author)

  14. Principle, possibilities and applications of gamma activation analysis

    International Nuclear Information System (INIS)

    Engelmann, C.

    1978-01-01

    The various photonuclear reactions suitable for analytical purposes, their specificity and their performances are reviewed. The influence of the experimental irradiation conditions on the theoretical detection limits permitted and on the relative importance of competitive nuclear reactions liable to interfere is examined, with special reference to the determination of carbon, nitrogen and oxygen. It is shown that these parasitic effects of nuclear origin may be eliminated by the choice of the maximum irradiation energy. Examples are given of applications relative to trace determinations of light elements, especially carbon, nitrogen and oxygen, in metals or semi-conductors and to instrumental multi-element analyses of biological materials, atmospheric sampling filters and above all agricultural products [fr

  15. Development of new techniques and enhancement of automatic capability of neutron activation analysis at the Dalat Research Reactor

    International Nuclear Information System (INIS)

    Ho Manh Dung; Ho Van Doanh; Tran Quang Thien; Pham Ngoc Tuan; Pham Ngoc Son; Tran Quoc Duong; Nguyen Van Cuong; Nguyen Minh Tuan; Nguyen Giang; Nguyen Thi Sy

    2017-01-01

    The techniques of neutron activation analysis (NAA) including cyclic, epithermal and prompt-gamma (CNAA, ENAA and PGNAA, respectively) have been developed at the Dalat research reactor (DRR). In addition, the efforts has been spent to improve the automatic capability of irradiation, measurement and data processing of NAA. The renewal of necessary devices/tools for sample preparation have also been done. Eventually, the performance and the utility in terms of sensitivity, accuracy and stability of the analytical results generated by NAA at DRR have significantly been improved. The main results of the project are: 1) Upgrading of the fast irradiation system on Channel 13-2/TC to allow the cyclic irradiations; 2) Development of CNAA; 3) Development of ENAA; 4) Application of k0-method for PGNAA; 5) Investigation of the automatic sample changer (ASC2); 6) Upgrading of Ko-DALAT software for ENAA and modification of k0-IAEA software for CNAA and PGNAA; and 7) Optimization of irradiation and measurement facilities as well as sample preparation devices/tools. A set of procedures of relevant developed techniques in the project were established. The procedures have been evaluated by analysis of the reference materials for which they are meeting the requirements of multi-element analysis for the intended applications. (author)

  16. Coupling meteorology, metal concentrations, and Pb isotopes for source attribution in archived precipitation samples.

    Science.gov (United States)

    Graney, Joseph R; Landis, Matthew S

    2013-03-15

    A technique that couples lead (Pb) isotopes and multi-element concentrations with meteorological analysis was used to assess source contributions to precipitation samples at the Bondville, Illinois USA National Trends Network (NTN) site. Precipitation samples collected over a 16month period (July 1994-October 1995) at Bondville were parsed into six unique meteorological flow regimes using a minimum variance clustering technique on back trajectory endpoints. Pb isotope ratios and multi-element concentrations were measured using high resolution inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) on the archived precipitation samples. Bondville is located in central Illinois, ~250km downwind from smelters in southeast Missouri. The Mississippi Valley Type ore deposits in Missouri provided a unique multi-element and Pb isotope fingerprint for smelter emissions which could be contrasted to industrial emissions from the Chicago and Indianapolis urban areas (~125km north and east, of Bondville respectively) and regional emissions from electric utility facilities. Differences in Pb isotopes and element concentrations in precipitation corresponded to flow regime. Industrial sources from urban areas, and thorogenic Pb from coal use, could be differentiated from smelter emissions from Missouri by coupling Pb isotopes with variations in element ratios and relative mass factors. Using a three endmember mixing model based on Pb isotope ratio differences, industrial processes in urban airsheds contributed 56±19%, smelters in southeast Missouri 26±13%, and coal combustion 18±7%, of the Pb in precipitation collected in Bondville in the mid-1990s. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Elemental mapping and quantitative analysis of Cu, Zn, and Fe in rat brain sections by laser ablation ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Brian [Dartmouth College, Departments of Earth Sciences and Chemistry, Hanover, NH (United States); Harper, Steve [University of Georgia, Savannah River Ecology Laboratory, Aiken, SC (United States); Smith, Laura; Flinn, Jane [George Mason University, Department of Psychology, Fairfax, VA (United States)

    2006-02-15

    This report details the application of laser ablation quadrupole ICP-MS for the (multi)elemental mapping of 100-{mu}m-thick sections of rat brain. The laser spot size used was 60 {mu}m, and the laser scan speed was 120 {mu}m s{sup -1}. The analysis was relatively rapid, allowing mapping of a whole brain thin section ({approx}1 cm{sup 2}) in about 2 h. Furthermore, the method was amenable to multi-element data collection including the physiologically important elements P and S and afforded sub {mu}g g{sup -1} detection limits for the important trace elements Cu and Zn. Calibrations were performed with pressed pellets of biological certified reference materials, and the elemental distributions and concentrations of Cu, Zn, and Fe were determined in whole rat brain sections. The distributions and concentration ranges for these elements were consistent with previous studies and demonstrate the utility of this technique for rapid mapping of brain thin sections. (orig.)

  18. Standoff Sensing Technology Based on Laser-Induced Breakdown Spectroscopy: Advanced Targeting, Surveillance and Reconnaissance in Security and Architectural Heritage Applications

    OpenAIRE

    Gaona Fernández, María Inmaculada

    2014-01-01

    Due to the ability to perform simultaneous, multi-element and real-time analysis without pretreatment and doing from a distance, laser induced breakdown spectroscopy (LIBS) in standoff mode is now considered a cutting-edge analytical technology. All these features have allowed its application in various fields such as security, environment, cultural heritage protection and space exploration, among the more outstanding. Nonetheless, the fact of working to long distances involves greater dif...

  19. Project Title: Radiochemical Analysis by High Sensitivity Dual-Optic Micro X-ray Fluorescence

    International Nuclear Information System (INIS)

    Havrilla, George J.; Gao, Ning

    2002-01-01

    A novel dual-optic micro X-ray fluorescence instrument will be developed to do radiochemical analysis of high-level radioactive wastes at DOE sites such as Savannah River Site and Hanford. This concept incorporates new X-ray optical elements such as monolithic polycapillaries and double bent crystals, which focus X-rays. The polycapillary optic can be used to focus X-rays emitted by the X-ray tube thereby increasing the X-ray flux on the sample over 1000 times. Polycapillaries will also be used to collect the X-rays from the excitation site and screen the radiation background from the radioactive species in the specimen. This dual-optic approach significantly reduces the background and increases the analyte signal thereby increasing the sensitivity of the analysis. A doubly bent crystal used as the focusing optic produces focused monochromatic X-ray excitation, which eliminates the bremsstrahlung background from the X-ray source. The coupling of the doubly bent crystal for monochromatic excitation with a polycapillary for signal collection can effectively eliminate the noise background and radiation background from the specimen. The integration of these X-ray optics increases the signal-to-noise and thereby increases the sensitivity of the analysis for low-level analytes. This work will address a key need for radiochemical analysis of high-level waste using a non-destructive, multi-element, and rapid method in a radiation environment. There is significant potential that this instrumentation could be capable of on-line analysis for process waste stream characterization at DOE sites

  20. Application of X-ray emission techniques for monitoring environmental pollution

    International Nuclear Information System (INIS)

    Bernasconi, G.; Danesi, P.R.; Dargie, M.; Haselberger, N.; Markowicz, A.; Tajani, A.

    1997-01-01

    X-ray emission techniques are versatile and powerful methods used for multielement non-destructive analysis. They include X-ray fluorescence (XRF), particle induced X-ray emission (PIXE), scanning electron microscopy combined with X-ray spectrometry and electron probe microanalysis (EPMA). Since many years the IAEA has utilised and promoted these techniques for the analysis of environmental, biological and geological samples. In this paper recent progress at our laboratory in selected aspects related to the application of X-ray emission techniques is briefly overviewed. (authors)

  1. An analysis of initial acquisition and maintenance of sight words following picture matching and copy cover, and compare teaching methods.

    OpenAIRE

    Conley, Colleen M; Derby, K Mark; Roberts-Gwinn, Michelle; Weber, Kimberly P; McLaughlin, T E

    2004-01-01

    This study compared the copy, cover, and compare method to a picture-word matching method for teaching sight word recognition. Participants were 5 kindergarten students with less than preprimer sight word vocabularies who were enrolled in a public school in the Pacific Northwest. A multielement design was used to evaluate the effects of the two interventions. Outcomes suggested that sight words taught using the copy, cover, and compare method resulted in better maintenance of word recognition...

  2. TXRF, PIXE, SYXRF; principles, critical comparison and applications

    International Nuclear Information System (INIS)

    Knoechel, A.

    1990-01-01

    At first glance X-Ray fluorescence analysis seems to be a very sensitive and effectful method to detect element traces in the multielement mode. But in praxi the application range is restricted, if X-Ray tubes are used as excitation sources. To overcome this situation, it is necessary to improve the conditions of excitation and to reduce the background, produced by different scattering effects. TXRF, PIXE and SYXRF, which allow multielement analysis in the trace- and ultratrace region are using this strategy. In the case of TXRF a remarkable background reduction is achieved if the sample is prepared as a thin amorphous film on a planar sample holder and the excitation beam of a X-Ray tube is totally reflected on its surface. In the case of PIXE a particle beam of high intensity is used as excitation source, improving the conditions of excitation and giving the opportunity of spatial resolved analyses. In the case of SYXRF the X-Ray fraction of synchrotron radiation is used as excitation source, giving the opportunity, to improve the conditions of excitation as well as to reduce the background by using the high polarisation of the beam. In this case, too, spatial resolved analysis are possible. The principles of the three methods are described, their advantages and disadvantages are critically compared and advanced applications from different analytical fields are presented. (orig.)

  3. Microwave-assisted versus conventional decomposition procedures applied to a ceramic potsherd standard reference material by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A

    2004-03-03

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a powerful, sensitive analytical technique with numerous applications in chemical characterization including that of ancient pottery, mainly due to its multi-element character, and the relatively short time required for the analysis. A critical step in characterization studies of ancient pottery is the selection of a suitable decomposition procedure for the ceramic matrix. The current work presents the results of a comparative study of six decomposition procedures applied on a standard ceramic potsherd reference material, SARM 69. The investigated decomposition procedures included three microwave-assisted decomposition procedures, one wet decomposition (WD) procedure by conventional heating, one combined microwave-assisted and conventional heating WD procedure, and one fusion procedure. Chemical analysis was carried out by ICP-AES. Five major (Si, Al, Fe, Ca, Mg), three minor (Mn, Ba, Ti) and two trace (Cu, Co) elements were determined and compared with their certified values. Quantitation was performed at two different spectral lines for each element and multi-element matrix-matched calibration standards were used. The recovery values for the six decomposition procedures ranged between 75 and 110% with a few notable exceptions. Data were processed statistically in order to evaluate the investigated decomposition procedures in terms of recovery, accuracy and precision, and eventually select the most appropriate one for ancient pottery analysis.

  4. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  5. Fully automated dissolution and separation methods for inductively coupled plasma atomic emission spectrometry rock analysis. Application to the determination of rare earth elements

    International Nuclear Information System (INIS)

    Govindaraju, K.; Mevelle, G.

    1987-01-01

    In rock analysis laboratories, sample preparation is a serious problem, or even an enormous bottleneck. Because this laboratory is production-oriented, this problem was attacked by automating progressively, different steps in rock analysis for major, minor and trace elements. This effort has been considerably eased by the fact that all sample preparation schemes in this laboratory for the past three decades have been based on an initial lithium borate fusion of rock samples and all analytical methods based on multi-element atomic emission spectrometry, with switch-over from solid analysis by arc/spark excitation to solution analysis by plasma excitation in 1974. The sample preparation steps which have been automated are: weighing of samples and fluxes, lithium borate fusion, dissolution and dilution of fusion products and ion-exchange separation of difficult trace elements such as rare earth elements (REE). During 1985 and 1986, these different unit operations have been assembled together as peripheral units in the form of a workstation, called LabRobStation. A travelling robot is the master of LabRobStation, with all peripheral units at its reach in 10 m 2 workspace. As an example of real application, the automated determination of REE, based on more than 8000 samples analysed during 1982 and 1986, is presented. (author)

  6. Optimization of geometry for X-ray analysis of rare earth materials

    International Nuclear Information System (INIS)

    Lal, M.; Choudhury, R.K.; Agrawal, R.M.

    1987-01-01

    A method of sample excitation is proposed for obtaining good sensitivity and detection limits for rare earth elements (57 241 Am radioisotope source. Detection limits of about 100-300 ng for most of the elements using a thin multi-element sample on a Mylar backing are obtained for a counting time of 1h with a 100 mCi source. The configuration employed is a close-coupled collimated side source geometry in which the sample is mounted at 45 0 to the plane of the detector. A comparative study of the performance of different source geometries using both Mylar- and cellulose-based samples is described. (author)

  7. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  8. Determination of impurities in beryl by neutron activation analysis

    International Nuclear Information System (INIS)

    Swain, K.K.; Dalvi, Aditi A.; Ajith, Nicy

    2015-01-01

    Beryl is a chemically complex and highly compositionally variable gem-forming mineral found in a variety of locations worldwide. Pure beryl is colorless, but the presence of impurities imparts colors such as green, blue, yellow, red, and white. It is one of the most important gem minerals and the gems are named by their color. The impurities in beryl can be determined using various analytical techniques. Neutron activation analysis (NAA) is a sensitive technique for multielement analysis of geological samples. Four beryl samples, collected from Nayakund Mehandi Block, Parseoni, Maharashtra, were received from Geological Survey of India (GSI), Pune. Powdered samples (50-100 mg) along with comparators (IAEA Soil-7) were packed in aluminum foils, sealed in an aluminum container and irradiated for 7 days in tray rod facility of Dhruva reactor, BARC, Mumbai. After irradiation, samples were brought to laboratory. Samples were opened, transferred into polyethylene packets and weighed. Gamma activity measurements were carried out using 45% HPGe detector coupled to 8 k multi channel analyzer. For the determination of manganese, which produces relatively shorter lived activation product ( 56 Mn: T 1/2 = 2.56 h), samples were sealed in polyethylene pouches and irradiated in graphite reflector position of Critical facility reactor, BARC, Mumbai. Relative method of NAA was used for concentration calculations. IAEA reference material (RM), SL -1 (lake sediment) was analyzed for quality control. Percentage errors on the measured concentrations of the elements are within ± 8% with respect to the recommended/information values

  9. k0-INAA for APM samples collected in period of June 2004 - March 2005 and some marine certified reference materials

    International Nuclear Information System (INIS)

    Dung, Ho Manh; Vu, Cao Dong; Y, Truong; Sy, Nguyen Thi

    2006-01-01

    The airborne particulate matter (APM) samples have been collected in 2004 using two types of polycarbonate membrane filter PM 2.5 and PM 2.5-10 at two sites of industrial (Ho Chi Mihn City) and rural (Dateh) regions in south of Vietnam. Three marine certified reference materials have been selected to establish a k0-NAA procedure for marine samples. The concentration of trace multi-element in the samples has been determined by the k 0 -INAA procedure using K o -DALAT software developed in Dalat NRI. About 28 elements in 224 APM samples collected at two areas of Dateh and HCMC of Vietnam in period from June, 2004 to March, 2005 were presented in report. The statistical analysis was applied to the data set to investigate the pollution source at sampling sites. The results proved that the k 0 -NAA on the Dalat research reactor is a reliable and effective analytical technique for characterization of trace multi-element in APM and marine samples for air and marine environmental pollution study in Vietnam. (author)

  10. A multielement analysis of natural radionuclides in an area of Pernambuco - Brazil

    International Nuclear Information System (INIS)

    Santos Junior, Jose Araujo dos; Menezes, Romulo Simoes Cezar

    2007-01-01

    Levels of natural radioactivity are the major cause of external exposure to gamma radiation. Based on this parameter, natural radioactivity of 238 U, 232 Th and 40 K were evaluated in a semiarid region of Pernambuco, Brazil, with the aim of obtaining radiometric monitoring of agricultural soils. For the analyses, the gamma spectrometry was utilized with a hyperpure germanium detector with an intrinsic efficiency of 27.7%. Seventy eight samples of soil that were collected in an area of approximately 55,500 m 2 , around an anomaly of uranium in rock, were analyzed. The activities of 238 U were evaluated by the 63 keV photopeak of 234 Th, that of 232 Th by the 338, 911 and 969 keV peak of 228 Ac, and that of 40 K by its 1,461 keV peak. The mean of the activities for these radionuclides were 91 Bq.kg -1 (median 88 Bq.kg -1 ) for the 238 U, 228 Bq.kg -1 (median 215 Bq.kg -1 ) for the 232 Th and 1,827 Bq.kg -1 (median 1,662 Bq.kg -1 ) for the 40 K. The anomalous rock did not present neither associated thorium nor potassium (values below the limit of detection: -1 of 232 Th and - '1 of 40 K), thus giving the characteristic of another natural radioactivity source. The obtained data allow to take important conclusions about the distribution of the radioactivity levels, to establish radioecological parameters. (author)

  11. Enantioselective stable isotope analysis (ESIA) — A new concept to evaluate the environmental fate of chiral organic contaminants

    International Nuclear Information System (INIS)

    Badea, Silviu-Laurentiu; Danet, Andrei-Florin

    2015-01-01

    Since 2011, the enantiospecific stable carbon isotope analysis (ESIA) has emerged as an innovative technique to assess the environmental fate of chiral emerging compounds by combining in one experimental technique both compound specific isotope analysis (CSIA) and enantioselective analysis. To date, the ESIA was applied for four classes of compounds: α-hexachlorocyclohexane (α-HCH), polar herbicides (phenoxy acids), synthetic polycyclic musk galaxolide (HHCB), and phenoxyalkanoic methyl herbicides. From an analytical point of view there are factors that are hindering the application of ESIA methods for the field samples: (i.e. amounts of target analyte, matrix effects, GC resolution) and overcoming these factors is challenging. While ESIA was shown as a mature technique for the first three abovementioned class of compounds, no isotope analysis of individual enantiomers could be performed for phenoxyalkanoic methyl herbicides. With respect to field studies, one study showed that ESIA might be a promising tool to distinguish between biotic and abiotic transformation pathways of chiral organic contaminants and even to differentiate between their aerobic and anaerobic biotransformation pathways. The development of ESIA methods for new chiral emerging contaminants in combination with development of multi-element isotope analysis will contribute to a better characterization of transformation pathways of chiral organic contaminants. - Highlights: • ESIA is an innovative technique to assess the environmental fate of chiral pollutants • Overcoming the analytical limitations of ESIA is challenging • Development of ESIA methods for new chiral emerging contaminants is needed

  12. Enantioselective stable isotope analysis (ESIA) — A new concept to evaluate the environmental fate of chiral organic contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Badea, Silviu-Laurentiu, E-mail: badeasilviu@gmail.com [Department of Chemistry, Umeå University, SE-901 87 Umeå (Sweden); Danet, Andrei-Florin [Department of Analytical Chemistry, University of Bucharest, Faculty of Chemistry, 90-92 Panduri Str., Bucharest 050657 (Romania)

    2015-05-01

    Since 2011, the enantiospecific stable carbon isotope analysis (ESIA) has emerged as an innovative technique to assess the environmental fate of chiral emerging compounds by combining in one experimental technique both compound specific isotope analysis (CSIA) and enantioselective analysis. To date, the ESIA was applied for four classes of compounds: α-hexachlorocyclohexane (α-HCH), polar herbicides (phenoxy acids), synthetic polycyclic musk galaxolide (HHCB), and phenoxyalkanoic methyl herbicides. From an analytical point of view there are factors that are hindering the application of ESIA methods for the field samples: (i.e. amounts of target analyte, matrix effects, GC resolution) and overcoming these factors is challenging. While ESIA was shown as a mature technique for the first three abovementioned class of compounds, no isotope analysis of individual enantiomers could be performed for phenoxyalkanoic methyl herbicides. With respect to field studies, one study showed that ESIA might be a promising tool to distinguish between biotic and abiotic transformation pathways of chiral organic contaminants and even to differentiate between their aerobic and anaerobic biotransformation pathways. The development of ESIA methods for new chiral emerging contaminants in combination with development of multi-element isotope analysis will contribute to a better characterization of transformation pathways of chiral organic contaminants. - Highlights: • ESIA is an innovative technique to assess the environmental fate of chiral pollutants • Overcoming the analytical limitations of ESIA is challenging • Development of ESIA methods for new chiral emerging contaminants is needed.

  13. Trace elements in the diets of Turkish children determined by INAA

    International Nuclear Information System (INIS)

    Aras, N.K.; Mauerhofer, E.; Naidu, R.K.; Arcasoy, A.; Denschlag, H.O.

    1992-01-01

    The role of toxic and essential trace elements in human diet is increasingly important because of environmental problems and the increasingly sophisticated industrial treatment of food products. Instrumental neutron activation analysis (INAA) is particularly well suited for multielement determinations. In order to test and demonstrated the usefulness of the method in connection with the fast pneumatic tube system of the Mainz TRIGA reactor, the authors have analyzed six diet samples of Turkish children

  14. Analysis of SMELS and reference materials for validation of the k0-based internal monostandard NAA method using in-situ detection efficiency

    Science.gov (United States)

    Acharya, R.; Swain, K. K.; Reddy, A. V. R.

    2010-10-01

    Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.

  15. Anodic electrode position of cyanometallates as sample preparation for the determination of transition metals from water samples using X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wundt, K.; Duschner, H.; Starke, K.

    1978-01-01

    The anodic separation of cyanometallates of propanol -2/Water mixtures at high electrical field strengths was developed as new technique for sample preparation. The optimization of the parameters of the system (high voltage applied, current density, separation time and composition of the solution) resulted in quantitative precipitation of the metallates of Fe, Co, Ni, Cu, Zn, Cd and Ag in homogeneous, thin and strong-adhering layer with mass densities of between 1 nmol cm -2 and 1 μmol cm -2 on high-purity aluminium foils. Metals not forming anionic complexes remain in solution with simualtaneous quantitative multielement separation. The described technique is part of a method to determine heavy metal traces in water samples. It comprises the nonspecific sorption on cation exchangers, the elution of the transition metals as cyanometallates, their electrode position on aluminium foil and the determination by X-ray fluorescence analysis. Model experiments illustrate the possible applications of the method. (orig.) [de

  16. Statistical Analysis of the Spatial Distribution of Multi-Elements in an Island Arc Region: Complicating Factors and Transfer by Water Currents

    Directory of Open Access Journals (Sweden)

    Atsuyuki Ohta

    2017-01-01

    Full Text Available The compositions and transfer processes affecting coastal sea sediments from the Seto Inland Sea and the Pacific Ocean are examined through the construction of comprehensive terrestrial and marine geochemical maps for western Japan. Two-way analysis of variance (ANOVA suggests that the elemental concentrations of marine sediments vary with particle size, and that this has a greater effect than the regional provenance of the terrestrial material. Cluster analysis is employed to reveal similarities and differences in the geochemistry of coastal sea and stream sediments. This analysis suggests that the geochemical features of fine sands and silts in the marine environment reflect those of stream sediments in the adjacent terrestrial areas. However, gravels and coarse sands do not show this direct relationship, which is likely a result of mineral segregation by strong tidal currents and the denudation of old basement rocks. Finally, the transport processes for the fine-grained sediments are discussed, using the spatial distribution patterns of outliers for those elements enriched in silt and clay. Silty and clayey sediments are found to be transported and dispersed widely by a periodic current in the inner sea, and are selectively deposited at the boundary of different water masses in the outer sea.

  17. Controlled dissolution of silicon dioxide layers for depth resolved multielement analysis by inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Lorge, Susan E.; Houk, R.S.

    2009-01-01

    Dissolution procedures were developed to control the number of surface layers removed, in an attempt to achieve depth resolved analysis by inductively coupled plasma-mass spectrometry (ICP-MS). NIST 612 glass was chosen because it is a homogeneous material with many elements at interesting concentrations, ∼ 50 ppm. Varying dissolution time and HF concentration resulted in the reproducible removal of SiO 2 layers as thin as 70 A deep. Dissolved trace metals were determined after dilution by inductively coupled plasma-mass spectrometry (ICP-MS) with a magnetic sector instrument. The amount removed was determined from the concentration of a major element, Ca. With the exception of Zn, trace metal concentrations agreed reasonably well with their certified values for removal depths of 500, 300 and 150 A. Zinc concentration was significantly high in all dissolutions indicating either a contamination problem or that Zn is removed at a faster rate than Ca. For the dissolutions that removed 70 A of SiO 2 , Cr, Mn, Co, Sr, Cd, Ce, Dy, Er, Yb and U recovery results agreed with their certified values (∼ 50 ppm); Ti, As, Mo, Ba, and Th could not be determined because net intensities were below 3σ of the blank; and measured concentrations for Cu, Pb and Zn were well above the certified values.

  18. Neutron activation analysis detection limits using 252Cf sources

    International Nuclear Information System (INIS)

    DiPrete, D.P.; Sigg, R.A.

    2000-01-01

    The Savannah River Technology Center (SRTC) developed a neutron activation analysis (NAA) facility several decades ago using low-flux 252 Cf neutron sources. Through this time, the facility has addressed areas of applied interest in managing the Savannah River Site (SRS). Some applications are unique because of the site's operating history and its chemical-processing facilities. Because sensitivity needs for many applications are not severe, they can be accomplished using an ∼6-mg 252 Cf NAA facility. The SRTC 252 Cf facility continues to support applied research programs at SRTC as well as other SRS programs for environmental and waste management customers. Samples analyzed by NAA include organic compounds, metal alloys, sediments, site process solutions, and many other materials. Numerous radiochemical analyses also rely on the facility for production of short-lived tracers, yielding by activation of carriers and small-scale isotope production for separation methods testing. These applications are more fully reviewed in Ref. 1. Although the flux [approximately2 x 10 7 n/cm 2 ·s] is low relative to reactor facilities, more than 40 elements can be detected at low and sub-part-per-million levels. Detection limits provided by the facility are adequate for many analytical projects. Other multielement analysis methods, particularly inductively coupled plasma atomic emission and inductively coupled plasma mass spectrometry, can now provide sensitivities on dissolved samples that are often better than those available by NAA using low-flux isotopic sources. Because NAA allows analysis of bulk samples, (a) it is a more cost-effective choice when its sensitivity is adequate than methods that require digestion and (b) it eliminates uncertainties that can be introduced by digestion processes

  19. Analysis of Indium Tin Oxide Film Using Argon Fluroide (ArF) Laser-Excited Atomic Fluorescence of Ablated Plumes.

    Science.gov (United States)

    Ho, Sut Kam; Garcia, Dario Machado

    2017-04-01

    A two-pulse laser-excited atomic fluorescence (LEAF) technique at 193 nm wavelength was applied to the analysis of indium tin oxide (ITO) layer on polyethylene terephthalate (PET) film. Fluorescence emissions from analytes were induced from plumes generated by first laser pulse. Using this approach, non-selective LEAF can be accomplished for simultaneous multi-element analysis and it overcomes the handicap of strict requirement for laser excitation wavelength. In this study, experimental conditions including laser fluences, times for gating and time delay between pulses were optimized to reveal high sensitivity with minimal sample destruction and penetration. With weak laser fluences of 100 and 125 mJ/cm 2 for 355 and 193 nm pulses, detection limits were estimated to be 0.10% and 0.43% for Sn and In, respectively. In addition, the relation between fluorescence emissions and number of laser shots was investigated; reproducible results were obtained for Sn and In. It shows the feasibility of depth profiling by this technique. Morphologies of samples were characterized at various laser fluences and number of shots to examine the accurate penetration. Images of craters were also investigated using scanning electron microscopy (SEM). The results demonstrate the imperceptible destructiveness of film after laser shot. With such weak laser fluences and minimal destructiveness, this LEAF technique is suitable for thin-film analysis.

  20. Investigation on trace elements in crude oil and organic matter extracted from rocks with instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ding Zuguo; Chai Zhifang

    1990-01-01

    Solvent extraction, column chromatography and instrumental neutron activation analysis(INAA) have been used to investigate the trace elements in crude oil, organic matter extracted from rocks and their related fractions. With these methods, about 70 crude oil samples from eight different oil fields in China and 6 extracted asphaltene samples of the lower paleozoic from the upper Yangtze region have been analyzed, and about 40 elements of interest have been determined. Those elements include Al, As, Au, Ba, Br, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, Ir, Mg, Mn, Mo, Na, Ni, Rb, Re, S, Sb, Sc, Se, Sr, Th, Zn, V and parts of REE. The experimental results show that the method possesses several advantages, i.e. non-destructive, multi-elements, sensitive, precise and accurate. Without ashing samples, the loss of volatile elements such as Cl, S, Se and Sb are avoided. The column chromatography makes it possible to study the distributions of trace elements in different fractions of crude oil and organic matter extracted. Meanwhile, the characters of trace elements in them have also been discussed

  1. A novel thick-film electrical conductivity sensor suitable for liquid and soil conductivity measurements

    OpenAIRE

    Atkinson, John; Sophocleous, Marios

    2015-01-01

    Results are reported from an initial evaluation of a novel conductivity sensor that could be incorporated onto a multi-element thick film (screen printed) sensor array designed for soil and water analysis. The new sensor exhibits a repeatable cell constant over a wide range of conductivities and is currently performing very well in an investigation of soil structural properties where its output is being correlated with soil water content in a study of different soil porosities.

  2. Lead and other elements in house dust of Japanese residences – Source of lead and health risks due to metal exposure

    International Nuclear Information System (INIS)

    Yoshinaga, Jun; Yamasaki, Kumiko; Yonemura, Ayumi; Ishibashi, Yuri; Kaido, Takaya; Mizuno, Kodai; Takagi, Mai; Tanaka, Atsushi

    2014-01-01

    The levels of 25 elements in house dust collected from 100 general Japanese residences were measured. Factor analysis was applied on the multi-element data to explore source of Pb (median concentration 49.1 mg/kg) in house dust. Six factors were extracted and Pb was found to have great loading on the fifth factor with Sb and Sn, suggesting solder (Sn), and plastic and metals (Sb) may be the sources of Pb in the house dust of Japanese residences. No significant loading was found on soil-related factors indicating non-significant contribution of Pb in track-in soil. Seven heavy metals (Cd, Cu, Mo, Pb, Sb, Sn, and Zn) were found in house dust at >10 times more condensed than crustal abundance. Health risk of these elements to children via the ingestion of house dust was estimated based on the comparison with tolerable daily intake and found to be non-significant for most of the elements. - Highlights: • Multi-element analysis was carried out for house dust from households in Japan. • Factor analysis was applied on the multivariate data set. • The abundance of lead had a close relationship with antimony and tin in house dust. • Health risk of heavy metals in house dust for children was not serious. - Major source of Pb in house dust of Japanese residences was not track-in soil but unknown materials that contain Pb and Sb and/or Sn

  3. Analytical methods applied to water pollution

    International Nuclear Information System (INIS)

    Baudin, G.

    1977-01-01

    A comparison of different methods applied to water analysis is given. The discussion is limited to the problems presented by inorganic elements, accessible to nuclear activation analysis methods. The following methods were compared: activation analysis: with gamma-ray spectrometry, atomic absorption spectrometry, fluorimetry, emission spectrometry, colorimetry or spectrophotometry, X-ray fluorescence, mass spectrometry, voltametry, polarography or other electrochemical methods, activation analysis-beta measurements. Drinking-water, irrigation waters, sea waters, industrial wastes and very pure waters are the subjects of the investigations. The comparative evaluation is made on the basis of storage of samples, in situ analysis, treatment and concentration, specificity and interference, monoelement or multielement analysis, analysis time and accuracy. The significance of the neutron analysis is shown. (T.G.)

  4. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  5. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  6. The application of a microstrip gas counter to energy-dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Veloso, J.F.C.A.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    Performance characteristics of a microstrip gas counter operated as a x-ray fluorescence spectrometer are reported. Gas amplification as a function of microstrip anode-cathode voltage was measured, and the breakdown threshold voltage was determined in pure xenon. The detector temporal stability and the effect of gas purity were assessed. Energy resolution and linearity, detection efficiency, and uniformity of spatial response in the 2- to 60-keV x-ray energy range were determined from the pulse-height distributions of the fluorescence x-ray spectra induced in a variety of single- and multi-element sample materials. Energy resolution similar to conventional proportional counters was achieved at 6 keV

  7. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  8. Analysis of the effect of mobile phone base station antenna loading on localized SAR and its consequences for measurements.

    Science.gov (United States)

    Hansson, Björn; Thors, Björn; Törnevik, Christer

    2011-12-01

    In this work, the effect of antenna element loading on the localized specific absorption rate (SAR) has been analyzed for base station antennas. The analysis was conducted in order to determine whether localized SAR measurements of large multi-element base station antennas can be conducted using standardized procedures and commercially available equipment. More specifically, it was investigated if the antenna shifting measurement procedure, specified in the European base station exposure assessment standard EN 50383, will produce accurate localized SAR results for base station antennas larger than the specified measurement phantom. The obtained results show that SAR accuracy is affected by the presence of lossy material within distances of one wavelength from the tested antennas as a consequence of coupling and redistribution of transmitted power among the antenna elements. It was also found that the existing standardized phantom is not optimal for SAR measurements of large base station antennas. A new methodology is instead proposed based on a larger, box-shaped, whole-body phantom. Copyright © 2011 Wiley Periodicals, Inc.

  9. Dynamic sequence analysis of a decision making task of multielement target tracking and its usage as a learning method

    Science.gov (United States)

    Kang, Ziho

    This dissertation is divided into four parts: 1) Development of effective methods for comparing visual scanning paths (or scanpaths) for a dynamic task of multiple moving targets, 2) application of the methods to compare the scanpaths of experts and novices for a conflict detection task of multiple aircraft on radar screen, 3) a post-hoc analysis of other eye movement characteristics of experts and novices, and 4) finding out whether the scanpaths of experts can be used to teach the novices. In order to compare experts' and novices' scanpaths, two methods are developed. The first proposed method is the matrix comparisons using the Mantel test. The second proposed method is the maximum transition-based agglomerative hierarchical clustering (MTAHC) where comparisons of multi-level visual groupings are held out. The matrix comparison method was useful for a small number of targets during the preliminary experiment, but turned out to be inapplicable to a realistic case when tens of aircraft were presented on screen; however, MTAHC was effective with large number of aircraft on screen. The experiments with experts and novices on the aircraft conflict detection task showed that their scanpaths are different. The MTAHC result was able to explicitly show how experts visually grouped multiple aircraft based on similar altitudes while novices tended to group them based on convergence. Also, the MTAHC results showed that novices paid much attention to the converging aircraft groups even if they are safely separated by altitude; therefore, less attention was given to the actual conflicting pairs resulting in low correct conflict detection rates. Since the analysis showed the scanpath differences, experts' scanpaths were shown to novices in order to find out its effectiveness. The scanpath treatment group showed indications that they changed their visual movements from trajectory-based to altitude-based movements. Between the treatment and the non-treatment group, there were no

  10. Assessment of metal sorption mechanisms by aquatic macrophytes using PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Módenes, A.N., E-mail: anmodenes@yahoo.com.br [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Espinoza-Quiñones, F.R.; Santos, G.H.F.; Borba, C.E. [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Rizzutto, M.A. [Physics Institute, University of São Paulo, Rua do Matão s/n, Travessa R 187, 05508-900 São Paulo, SP (Brazil)

    2013-10-15

    Highlights: • Divalent metal ion removals by Egeria densa biosorbent. • Multielements concentrations in biosorbent samples by PIXE analysis. • Elements mass balance in liquid and solid phase before and after metal removals. • Assessment of the mechanisms involved in Cd{sup 2+} and Zn{sup 2+} removal by biosorbent. • Confirmation of the signature of ion exchange process in metal removal. -- Abstract: In this work, a study of the metal sorption mechanism by dead biomass has been performed. All batch metal biosorption experiments were performed using the aquatic macrophyte Egeria densa as biosorbent. Divalent cadmium and zinc solutions were used to assess the sorption mechanisms involved. Using a suitable equilibrium time of 2 h and a mixture of 300 mg biosorbent and 50 mL metal solution at pH 5, monocomponent sorption experiments were performed. In order to determine the residual amounts of metals in the aqueous solutions and the concentrations of removed metals in the dry biomass, Particle Induced X-ray Emission (PIXE) measurements in thin and thick target samples were carried out. Based on the strong experimental evidence from the mass balance among the major elements participating in the sorption processes, an ion exchange process was identified as the mechanism responsible for metal removal by the dry biomass.

  11. National Uranium Resource Evaluation Program (NURE): hydrogeochemical and stream sediment reconnaissance in the eastern United States

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Price, V. Jr.

    1976-01-01

    A geochemical reconnaissance of twenty-five eastern states for uranium will be conducted by the Savannah River Laboratory for the U.S. Energy Research and Development Administration. A sound technical basis for the reconnaissance is being developed by intensive studies of sampling, analysis, and data management. Results of three orientation studies in the southern Appalachian Piedmont and Blue Ridge areas indicate that multi-element analysis of -100 mesh (less than 149 μm) stream sediments will provide adequate information for reconnaissance. Stream and groundwater samples also provide useful information but are not considered cost-effective for regional reconnaissance in the areas studied

  12. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    International Nuclear Information System (INIS)

    Xue Yongjie; Hou Haobo; Zhu Shujing

    2009-01-01

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO 3 . In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH 50 (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems

  13. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yongjie [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China); Wuhan Kaidi Electric Power Environmental Protection Co. Ltd., Hubei, Wuhan (China)], E-mail: xueyj@mail.whut.edu.cn; Hou Haobo; Zhu Shujing [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China)

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO{sub 3}. In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH{sub 50} (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  14. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag.

    Science.gov (United States)

    Xue, Yongjie; Hou, Haobo; Zhu, Shujing

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01M NaNO(3). In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84mM in the single element system and 0.21mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH(50) (the pH at which 50% adsorption occurs) was found to follow the sequence Zn>Cu>Pb>Cd in single-element systems, but Pb>Cu>Zn>Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  15. Optimum operation of a direct-reading spectrometer with excitation by a 5kW inductively coupled plasma torch

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Russell, G.M.

    1981-01-01

    An examination was made of the optimum operating conditions, degree of interference from sodium ionization, and spectral interferences in a simultaneous 40-channel spectrometer having a data-reduction system controlled by a microprocessor. Excitation is provided by an inductively coupled plasma (ICP) source of medium power, i.e., with a nominal maximum of 5kW. The optimum conditions were ascertained for atomic lines, for ionic lines, and for compromise multi-element analysis in aqueous solutions and in sodium solutions at concentrations up to 30 g/l, the detection limits for 37 elements being determined. It was found that an increase of approximately 30 per cent in the power input under the optimum conditions for multi-element operation reduced the interference from ionization caused by up to 30 g of sodium per litre to less than 5 per cent relative. It was found that there is a correlation between the extent of the interference from ionization and the ionization potential of an element. Although the great majority of the lines in the spectral array were generally free of significant spectral overlap, several serious spectral interferences were observed and were determined quantitatively

  16. Elemental analysis of forensic glasses by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Almirall, Jose R.; Duckworth, Douglas C.; Bayne, Charles K.; Morton, Sherman A.; Smith, David H.; Koons, Robert D.; Furton, Kenneth G.

    1999-02-01

    Flat glass is a common type of evidence collected from the scenes of crimes such as burglaries, vandalism, and hit-and- run accidents. The usefulness of such evidence lies in the ability to associate the glass from the scene (or a suspect) to the original source. Physical and chemical analysis of the glass can be used for discrimination between the possible sources of glass. If the sample is large enough, physical attributes such as fracture matches, density, color, and thickness can be employed for comparison between a recovered fragment(s) to the suspect source. More commonly, refractive index (RI) comparisons are employed. Due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses where approximately 6 - 9% of casework samples are not expected to be distinguished by RI alone even if they originated from different sources. Employing methods such as NAA, XRF, ICP-AES, and ICP-MS for the comparison of trace elemental compositions has been shown to be more discriminating than RI comparisons. The multielement capability and the sensitivity of ICP-AES and ICP-MS provide for excellent discrimination power. In this work, the sources of variability in ICP-MS of glass analysis are investigated to determine possible sources of variation. The sources of variation examined include errors due to sample preparation, instrument accuracy and precision, and interlaboratory reproducibility. Other sources of variation include inhomogeneity across a sheet of glass from the same source. Analysis of variance has been applied to our ICP-MS analysis of NIST standards and to the interlaboratory comparisons of float glass samples collected across a sheet in a production facility. The results of these experiments allows for a more accurate interpretation of forensic glass data and a better understanding of the discriminating power (absolute and practical) of ICP-MS.

  17. Modeling and Grid Generation of Iced Airfoils

    Science.gov (United States)

    Vickerman, Mary B.; Baez, Marivell; Braun, Donald C.; Hackenberg, Anthony W.; Pennline, James A.; Schilling, Herbert W.

    2007-01-01

    SmaggIce Version 2.0 is a software toolkit for geometric modeling and grid generation for two-dimensional, singleand multi-element, clean and iced airfoils. A previous version of SmaggIce was described in Preparing and Analyzing Iced Airfoils, NASA Tech Briefs, Vol. 28, No. 8 (August 2004), page 32. To recapitulate: Ice shapes make it difficult to generate quality grids around airfoils, yet these grids are essential for predicting ice-induced complex flow. This software efficiently creates high-quality structured grids with tools that are uniquely tailored for various ice shapes. SmaggIce Version 2.0 significantly enhances the previous version primarily by adding the capability to generate grids for multi-element airfoils. This version of the software is an important step in streamlining the aeronautical analysis of ice airfoils using computational fluid dynamics (CFD) tools. The user may prepare the ice shape, define the flow domain, decompose it into blocks, generate grids, modify/divide/merge blocks, and control grid density and smoothness. All these steps may be performed efficiently even for the difficult glaze and rime ice shapes. Providing the means to generate highly controlled grids near rough ice, the software includes the creation of a wrap-around block (called the "viscous sublayer block"), which is a thin, C-type block around the wake line and iced airfoil. For multi-element airfoils, the software makes use of grids that wrap around and fill in the areas between the viscous sub-layer blocks for all elements that make up the airfoil. A scripting feature records the history of interactive steps, which can be edited and replayed later to produce other grids. Using this version of SmaggIce, ice shape handling and grid generation can become a practical engineering process, rather than a laborious research effort.

  18. The strongest spectral lines of stable elements with other interfering elements in compiled and plotted version

    International Nuclear Information System (INIS)

    Bauer, M.; Weitkamp, C.

    1977-01-01

    The strongest spectra lines of the 85 stable chemical elements have been compiled and plotted along with lines from other elements that may interfere in applications like spectroscopic multielement analysis. For each line a wavelength range of +- 0.25 A.U. around the line of interest has been considered. The tables contain the wavelength, intensity and assignment to an ionization state of the emitting atom, the plots visualize the lines with a doppler broadening corresponding to 8,000 K. (orig.) [de

  19. Proton-induced X-ray emission analysis of marine particulates

    International Nuclear Information System (INIS)

    Burnett, W.C.; Mitchum, G.T.

    1981-01-01

    We report a methodology used to analyze suspended marine particulates by particle induced X-ray emission (PIXE). Water samples from an estuary in Brazil were filtered soon after collection onto pre-weighed Nuclepore filters, washed with deionized water, dried to constant weight and analyzed as thin targets. Because of the relatively high mass loadings (0.1-1.0 mg/cm 2 ) on the filters, proton bombardment times of a few minutes were adequate for maintaining good counting statistics. Precision and accuary were determined by replicate analysis and intercomparison to geochemical standards. Suspensions of standards in deionized water were filtered dried, weighed and analyzed in a similar fashion as our samples of marine particulates. Net X-ray intensities were related to mass by calibration against pure elemental standards. Initial experiments showed systematically low concentrations for all elements determined by PIXE relative to known values. Further experiments verified that this systematic errors was due to an uneven distribution of mass on the surface of the filters. Improvements in the filtration technique have eliminated the topographic effect on our samples and the PIXE resultes were substantially improved. Variations in matrix and particle size of the samples analyzed did not cause any measureable analytical effect. PIXE thus seems well suited for providing rapid, multi-element data on samples of marine particulates if suitable precautions are made during the sample preparation process. (orig.)

  20. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.

    Science.gov (United States)

    Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika

    2005-12-01

    The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and

  1. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    International Nuclear Information System (INIS)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A.

    2004-01-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  2. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Zachariadis, G.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Anthemidis, A.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Tsirliganis, N.C. [Archaeometry Laboratory, Cultural and Educational Technology Institute, Tsimiski 58, GR-67100, Xanthi (Greece); Stratis, J.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece)]. E-mail: jstratis@chem.auth.gr

    2004-12-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  3. Solution of multi-element LED light sources development automation problem

    Science.gov (United States)

    Chertov, Aleksandr N.; Gorbunova, Elena V.; Korotaev, Valery V.; Peretyagin, Vladimir S.

    2014-09-01

    The intensive development of LED technologies resulted in the creation of multicomponent light sources in the form of controlled illumination devices based on usage of mentioned LED technologies. These light sources are used in different areas of production (for example, in the food industry for sorting products or in the textile industry for quality control, etc.). The use of LED lighting products in the devices used in specialized lighting, became possible due to wide range of colors of light, LED structures (which determines the direction of radiation, the spatial distribution and intensity of the radiation, electrical, heat, power and other characteristics), and of course, the possibility of obtaining any shade in a wide dynamic range of brightness values. LED-based lighting devices are notable for the diversity of parameters and characteristics, such as color radiation, location and number of emitters, etc. Although LED technologies have several advantages, however, they require more attention if you need to ensure a certain character of illumination distribution and/or distribution of the color picture at a predetermined distance (for example, at flat surface, work zone, area of analysis or observation). This paper presents software designed for the development of the multicomponent LED light sources. The possibility of obtaining the desired color and energy distribution at the zone of analysis by specifying the spatial parameters of the created multicomponent light source and using of real power, spectral and color parameters and characteristics of the LEDs is shown as well.

  4. Trace metal analysis in sea grasses from Mexican Caribbean Coast by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Solis, C.; Issac O, K.; Martinez, A.; Lavoisier, E.; Martinez, M. A.

    2008-01-01

    The growing urban and tourist activity in the Mexican Caribbean coasts has resulted in an increase of chemical substances, metals in particular, discharged to the coastal waters. In order to reach an adequate management and conservation of these marine ecosystems it is necessary to perform an inventory of the actual conditions that reflect the vulnerability and the level of damage. Sea-grasses are considered good biological indicators of heavy metal contamination in marine systems. The goal of this preliminary work is to evaluate the concentrations of trace metals such as Cr, Mn, Fe, Co, Cu, Zn, and Pb in Thalassia testudinum, a very common sea-grass in the Mexican Caribbean Sea. Samples were collected from several locations in the coasts of the Yucatan Peninsula: Holbox, Blanquizal and Punta Allen, areas virtually uninfluenced by anthropogenic activities. Trace elements in different part plants were determined by particle induced X-ray emission (PIXE). This is a very suitable technique since it offers a fast, accurate and multi-element analysis. Also, the analysis by PIXE can be performed directly on powdered leaves without a laborious sample preparation. The trace metal concentration determined in sea-grasses growing in Caribbean generally fall in the range of the lowest valuables reported for sea grasses from the Gulf of Mexico. The results indicate that the studied areas do not present contamination by heavy metals. (Author)

  5. Evaluasi Ketidakpastian Pengukuran Multi-Unsur Dalam Mineral Zirkon Dengan Metode Analisis Aktivasi Neutron

    Directory of Open Access Journals (Sweden)

    Sukirno

    2015-05-01

    Full Text Available The evaluation of multi-elements analysis has been carried out with calculation of element uncertainy in the zircon mineral from Sampit (Central Kalimantan dan Bangka has been evaluated by the Neutron Activation Analysis (NAA method. The purpose of this research is determination of composition and value of multi-elements uncertainty in the mineral of zircon to fulfil the requirements of ISO/IEC guide 17025-2008 that applied at NAA laboratory. The result of analysis using gamma spectrometry with a HPGe detector showed of 21 detected elements, divided into three groups (major, minor, and trace. Evaluation of uncertainty estimation should be done to increase quality and confidence rate of analysis results. The result of testing are not mean without calculation of uncertainty. Therefore, it was assessed the uncertainty measurement of all elements analysis in zircon mineral. The results of quantitative analysis is Zr with the highest concentration value of 38.986% and value of uncertainty is 0.331% so that value of real concentration is 38.986 ± 0.331%. In the form of oxide (ZrO2 has concentration of 52.661±0.45%. Sb element is the lowest element detected with value of concentration and uncertainty is 7±0,3 µg/g. In the form of oxide (Sb2O3 has concentration is 17±0.9 µg/g. The oxide composition and the must important of chemicals in the zircon sand mineral more significant from Sampit which quantitative composition areZrO2+HfO2 (53-55%, F2O3 (5-6%, TiO2 (13-14%, Al2O3 (1.5-2% and SiO2. Elements ofSi(SiO2 can not be determined by NAA method because Si cross-sections is verysmall.

  6. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  7. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  8. Decomposition techniques

    Science.gov (United States)

    Chao, T.T.; Sanzolone, R.F.

    1992-01-01

    Sample decomposition is a fundamental and integral step in the procedure of geochemical analysis. It is often the limiting factor to sample throughput, especially with the recent application of the fast and modern multi-element measurement instrumentation. The complexity of geological materials makes it necessary to choose the sample decomposition technique that is compatible with the specific objective of the analysis. When selecting a decomposition technique, consideration should be given to the chemical and mineralogical characteristics of the sample, elements to be determined, precision and accuracy requirements, sample throughput, technical capability of personnel, and time constraints. This paper addresses these concerns and discusses the attributes and limitations of many techniques of sample decomposition along with examples of their application to geochemical analysis. The chemical properties of reagents as to their function as decomposition agents are also reviewed. The section on acid dissolution techniques addresses the various inorganic acids that are used individually or in combination in both open and closed systems. Fluxes used in sample fusion are discussed. The promising microwave-oven technology and the emerging field of automation are also examined. A section on applications highlights the use of decomposition techniques for the determination of Au, platinum group elements (PGEs), Hg, U, hydride-forming elements, rare earth elements (REEs), and multi-elements in geological materials. Partial dissolution techniques used for geochemical exploration which have been treated in detail elsewhere are not discussed here; nor are fire-assaying for noble metals and decomposition techniques for X-ray fluorescence or nuclear methods be discussed. ?? 1992.

  9. An analysis of initial acquisition and maintenance of sight words following picture matching and copy cover, and compare teaching methods.

    Science.gov (United States)

    Conley, Colleen M; Derby, K Mark; Roberts-Gwinn, Michelle; Weber, Kimberly P; McLaughlin, T E

    2004-01-01

    This study compared the copy, cover, and compare method to a picture-word matching method for teaching sight word recognition. Participants were 5 kindergarten students with less than preprimer sight word vocabularies who were enrolled in a public school in the Pacific Northwest. A multielement design was used to evaluate the effects of the two interventions. Outcomes suggested that sight words taught using the copy, cover, and compare method resulted in better maintenance of word recognition when compared to the picture-matching intervention. Benefits to students and the practicality of employing the word-level teaching methods are discussed.

  10. Determination of ash concentration and coal calorific values of coal directly on the conveyor belt; Bestimmung der Aschegehalte und Heizwerte von Kohlen direkt auf dem Foerderband

    Energy Technology Data Exchange (ETDEWEB)

    Wess, Juergen [PANalytical GmbH, Kassel (Germany)

    2012-07-01

    Among the multi-element methods of instrumental analyses, the neutron activation analysis takes a special position. The method is able to penetrate even thick layers of samples and covers whole mass flows online, like on conveyor belts. A new technique of pulsed excitation allows the reduction of undesired components of analytical gamma-rays, which allows the determination of carbon, oxygen and hydrogen. Therefore, the ash content, based on the ash containing elements, and the calorific values, based on calculation models, can be measured in one process. (orig.)

  11. Use of nuclear and related analytical techniques in environmental research as exemplified by selected air pollution studies

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Jeran, Z.; Stropnik, B.; Svetina, M.

    2000-01-01

    Among nuclear and nuclear related analytical techniques, neutron activation analysis and X-ray fluorescence spectrometry proved to be particularly useful for environmental studies owing to their nondestructive character and multi element capability. This paper emphasizes their importance among other multielement analytical methods by discussing their specific role due to specific physics basis, quite different to other destructive non-nuclear methods, and by summarizing results obtained in several studies related to air pollution research, including analyses of airborne particulate matter, water samples, lichens and mosses. (author)

  12. A software architectural framework specification for neutron activation analysis

    International Nuclear Information System (INIS)

    Preston, J.A.; Grant, C.N.

    2013-01-01

    Neutron Activation Analysis (NAA) is a sensitive multi-element nuclear analytical technique that has been routinely applied by research reactor (RR) facilities to environmental, nutritional, health related, geological and geochemical studies. As RR facilities face calls to increase their research output and impact, with existing or reducing budgets, automation of NAA offers a possible solution. However, automation has many challenges, not the least of which is a lack of system architecture standards to establish acceptable mechanisms for the various hardware/software and software/software interactions among data acquisition systems, specialised hardware such as sample changers, sample loaders, and data processing modules. This lack of standardization often results in automation hardware and software being incompatible with existing system components, in a facility looking to automate its NAA operations. This limits the availability of automation to a few RR facilities with adequate budgets or in-house engineering resources. What is needed is a modern open system architecture for NAA, that provides the required set of functionalities. This paper describes such an 'architectural framework' (OpenNAA), and portions of a reference implementation. As an example of the benefits, calculations indicate that applying this architecture to the compilation and QA steps associated with the analysis of 35 elements in 140 samples, with 14 SRM's, can reduce the time required by over 80 %. The adoption of open standards in the nuclear industry has been very successful over the years in promoting interchangeability and maximising the lifetime and output of nuclear measurement systems. OpenNAA will provide similar benefits within the NAA application space, safeguarding user investments in their current system, while providing a solid path for development into the future. (author)

  13. A TLD dose algorithm using artificial neural networks

    International Nuclear Information System (INIS)

    Moscovitch, M.; Rotunda, J.E.; Tawil, R.A.; Rathbone, B.A.

    1995-01-01

    An artificial neural network was designed and used to develop a dose algorithm for a multi-element thermoluminescence dosimeter (TLD). The neural network architecture is based on the concept of functional links network (FLN). Neural network is an information processing method inspired by the biological nervous system. A dose algorithm based on neural networks is fundamentally different as compared to conventional algorithms, as it has the capability to learn from its own experience. The neural network algorithm is shown the expected dose values (output) associated with given responses of a multi-element dosimeter (input) many times. The algorithm, being trained that way, eventually is capable to produce its own unique solution to similar (but not exactly the same) dose calculation problems. For personal dosimetry, the output consists of the desired dose components: deep dose, shallow dose and eye dose. The input consists of the TL data obtained from the readout of a multi-element dosimeter. The neural network approach was applied to the Harshaw Type 8825 TLD, and was shown to significantly improve the performance of this dosimeter, well within the U.S. accreditation requirements for personnel dosimeters

  14. Status of neutron activation analysis in developing countries

    International Nuclear Information System (INIS)

    Chatt, A.

    1996-01-01

    The 60th anniversary of the discovery of neutron activation analysis (NAA) by Hevesy and Levi is being celebrated in 1996. With the availability of nuclear reactors capable of producing fluxes of the order of 10 12 to 10 14 n/cm 2 s, the development of high-resolution and high-efficiency conventional and anticoincidence gamma-ray detectors, multichannel pulse-height analyzers, and personal computer-based softwares, NAA has become an extremely valuable analytical technique, especially for the simultaneous determinations of multielement concentrations. This technique can be used in a number of ways, depending on the nature of the matrix, the major elements in the sample, and on the elements of interest. In most cases, several elements can be determined without any chemical pretreatment of the sample; the technique is then called instrumental NAA (INAA). In other cases, an element can be concentrated from an interfering matrix prior to irradiation; the technique is then termed preconcentration NAA (PNAA). In opposite instances, the irradiation is followed by a chemical separation of the desired element; the technique is then called radiochemical NAA (RNAA). All three forms of NAA can provide elemental concentrations of high accuracy and precision with excellent sensitivity. The number of research reactors in developing countries has increased steadily from 17 in 1955 through 71 in 1975 to 89 in 1995. Low flux reactors such as SLOWPOKE and the Chinese MNSR are primarily used for NAA

  15. Determination of multi-element composition of Vietnamese marine sediment and tuna fish by k0-standardized neutron activation analysis

    International Nuclear Information System (INIS)

    Manh-Dung Ho; Quang-Thien Tran; Van-Doanh Ho; Thi-Sy Nguyen

    2016-01-01

    The k 0 -standardized neutron activation analysis (k 0 -NAA) has been applied for determination of multiple elements (25 elements: Al, As, Ba, Br, Ca, Cl, Co, Cr, Cs, Cu, Eu, Fe, Hg, K, La, Mg, Na, Rb, Sc, Se, Sm, Th, Ti, V and Zn) in marine sediment and tuna fish. About 50 marine sediment and 9 tuna fish samples were collected in two coastal areas of Vietnam. The health risk index (HRI) values of As and Br were higher than 1.0 for the tuna fish. Also, HRI value of Hg was 8.92 × 10 -1 indicating a relatively high potential health risk, whiles Co and Mn with HRIs = 1.56 × 10 -4 and 8.56 × 10 -4 , respectively, have the lowest potential health risks. Average enrichment factors using Al as a reference element (EF Al ) were higher than 1.5 for Eu, La, Zn, Th, Cs and As in which the highest EF Al value for As was higher than 10. This study showed that the HRI value of As in the tuna fish correlated positively with the EF Al value for the element in the marine sediment. (author)

  16. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  17. Transverse-structure electrostatic charged particle beam lens

    Science.gov (United States)

    Moran, M.J.

    1998-10-13

    Electrostatic particle-beam lenses using a concentric co-planar array of independently biased rings can be advantageous for some applications. Traditional electrostatic lenses often consist of axial series of biased rings, apertures, or tubes. The science of lens design has devoted much attention to finding axial arrangements that compensate for the substantial optical aberrations of the individual elements. Thus, as with multi-element lenses for light, a multi-element charged-particle lens can have optical behavior that is far superior to that of the individual elements. Transverse multiple-concentric-ring lenses achieve high performance, while also having advantages in terms of compactness and optical versatility. 7 figs.

  18. Study of optical emission spectroscopy with inductively coupled plasma torch

    International Nuclear Information System (INIS)

    Bauer, M.

    1982-01-01

    Inductively coupled plasma optical emission spectroscopy is an excellent tool for quantitative multielement trace analysis. This paper describes the performance of a computer-controlled sequential measurement system. Chemical and ionization interferences are shown to be negligible due to the characteristics of the inductively coupled plasma, spectral interferences are eliminated by using a high-resolution monochromator and computer data handling. Good accuracy is achieved for most of the interesting elements, as is shown from both an interlaboratory test and from comparison of the results of water samples from the rivers Elbe and Weser with those achieved with neutron activation and X-ray fluorescence analysis. (orig.) [de

  19. NAA in characterization of matrices at ACD, BARC

    International Nuclear Information System (INIS)

    Rajan A, Nicy; Swain, Kallola K.; Kayasth, Satish

    2006-01-01

    The use of characterization in material science means an approach that indicates those features of materials related to its composition and structure. In simple terms, characterization of a material means what atoms are present and where they are. In general characterization deals with the complete and accurate information of composition of the material (major, minor, trace elements) for specific application. Neutron activation analysis (NAA) is identified as one of the most powerful analytical technique useful for performing both qualitative and quantitative multi-element analysis of major, minor, and trace elements in almost every conceivable field of scientific/technical interest and is extensively used for wide variety of materials

  20. Quality in the chemical analysis of biological matrices by fluorescence X-ray by energy dispersive; Qualidade nas analises quimicas de matrizes biologicas pela fluorescencia de raios-X por dispersao de energia

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Evely E. de; Paiva, Jose Daniel S. de; Franca, Elvis J. de; Almeida, Macio E.S.; Cantinha, Rebeca S.; Hazin, Clovis A., E-mail: evelysousa_182@hotmail.com, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    The aim of this study was to obtain multielement analytical curves of high analytical rigor to the analysis of biological matrices by the technique of fluorescence x-ray energy dispersive - EDXRF. Calibration curves were constructed from the reference materials IAEA 140, IAEA 155, IAEA V8, V10 to the International Atomic Energy Agency - IAEA, and SRM1515, SRM 1547, SRM 1570a, SRM 1573a, SEM 1567a, to the National Institute of Standards and Technology - NIST. After energy calibration, all samples were subjected to vacuum to the analyzes by 100 seconds for each group of chemical elements. The voltages used were respectively 15 keV for chemical elements with less than atomic number 22 and 50 keV for the others. After the construction of the curves, the analytical quality was assessed by the analysis of a portion-test of the reference material SRM 2976, also produced by NIST. Based on the number of certified reference materials used for construction of calibration curves in this work, quality analytical protocol was originated with considerable reliability for quantification of chemical elements in biological samples by EDXR.

  1. Materials characterization of radioactive waste forms using a multi-element detection method based on the instrumental neutron activation analysis. MEDINA

    International Nuclear Information System (INIS)

    Havenith, Andreas Wilhelm

    2015-01-01

    Radioactive waste has to meet the specifications and acceptance criteria defined by national regulatory and management authorities for its intermediate and final storage. In Germany the Federal Office for Radiation Protection (Bundesamt fuer Strahlenschutz - BfS) has established waste acceptance requirements for the Konrad repository. Konrad is the disposal for radioactive waste with negligible heat generation and is located near the city of Salzgitter and is currently under construction. It will start operation not before the year 2021. The waste-acceptance-requirements are derived from a site-specific safety assessment. They include specific requirements on waste forms, packaging as well as limitations to activities of individual radionuclides and limitations to masses of non-radioactive harmful substances. The amount of chemically toxic elements in the waste is limited in order to avoid pollution of underground water reserves. To comply with these requirements every waste package has to be characterised in its radiological and chemical composition. This characterisation can be performed on the basis of existing documentation or, if the documentation is insufficient, on further analytical analysis. Segmented or integral gamma-scanning as well as active or passive neutron counting are used worldwide as the standard measurement methods for the radiological characterisation and quality checking of radioactive waste. These techniques determine the isotope specific activity of waste packages, but they do not allow the detection of non-radioactive hazardous substances inside the waste packages. Against this background the Institute of Nuclear Engineering and Technology Transfer (NET) at RWTH Aachen University and the Institute of Safety Research and Reactor Technology at Forschungszentrum Juelich jointly develop an innovative non-destructive analytical technique called MEDINA - ''Multi-Element Detection based on Instrumental Neutron Activation'' for

  2. High sensitivity isotope analysis with a 252Cf--235U fueled subcritical multiplier and low background photon detector systems

    International Nuclear Information System (INIS)

    Wogman, N.A.; Rieck, H.G. Jr.; Laul, J.C.; MacMurdo, K.W.

    1976-09-01

    A 252 Cf activation analysis facility has been developed for routine multielement analysis of a wide variety of solid and liquid samples. The facility contains six sources of 252 Cf totaling slightly over 100 mg. These sources are placed in a 93 percent 235 U-enriched uranium core which is subcritical with a K effective of 0.985 (multiplication factor of 66). The system produces a thermal flux on the order of 10 +1 neutrons per square centimeter per second. A pneumatic rabbit system permits automatic irradiation, decay, and counting regimes to be performed unattended on the samples. The activated isotopes are analyzed through their photon emissions with state-of-the-art intrinsic Ge detectors, Ge(Li) detectors, and NaI(Tl) multidimensional gamma ray spectrometers. High efficiency (25 percent), low background, anticoincidence shielded Ge(Li) gamma ray detector systems have been constructed to provide the lowest possible background, yet maintain a peak to Compton ratio of greater than 1000 to 1. The multidimensional gamma ray spectrometer systems are composed of 23 cm diameter x 20 cm thick NaI(Tl) crystals surrounded by NaI(Tl) anticoincidence shields. The detection limits for over 65 elements have been determined for this system. Over 40 elements are detectable at the 1 part per million level at a precision of +-10 percent

  3. Geochemical of trace elements in volcanics rocks Peninsula Fildes, Fildes Bay Rey Jorge island, south Shetland

    International Nuclear Information System (INIS)

    Masquelin, H.; Vaz Chavez, N.

    1987-01-01

    The authors present some geochemical data derived from the multielement analysis of three different types of volcanic rocks collected around Fildes Bay on King George Island, South Shetland. Volcanic rocks from Fildes Peninsula Group may be distinguished from those Marian Cove by their hydrothermal alteration. Apparently the correlation between NI ands Cr allows for the observation of the stratigraphic separation of samples of the same kind. Consequently, the correlation between Cu and As show a distinction between Marian Cove propylitised tuffites and both Brecciated Andesites and pyroclastic rock from Fildes Peninsula Group.

  4. High-resolution continuum source atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple lines. A critical review of current possibilities

    International Nuclear Information System (INIS)

    Resano, M.; Flórez, M.R.; García-Ruiz, E.

    2013-01-01

    This work examines the capabilities and limitations of commercially available high-resolution continuum source atomic absorption spectrometry instrumentation for multi-line monitoring, discussing in detail the possible strategies to develop multi-element methodologies that are truly simultaneous, or else sequential, but from the same sample aliquot. Moreover, the simultaneous monitoring of various atomic or molecular lines may bring other important analytical advantages, such as: i) expansion of the linear range by monitoring multiplets; ii) improvements in the limit of detection and in precision by summing the signals from different lines of the same element or molecule; iii) simple correction for matrix-effects by selecting a suitable internal standard; or iv) accurate mathematical correction of spectral overlaps by simultaneous monitoring of free lines of the interfering molecule or element. This work discusses how authors have made use of these strategies to develop analytical methodologies that permit the straightforward analysis of complex samples. - Highlights: • HR CS AAS potential for simultaneous multi-line monitoring is critically examined. • Strategies to develop simultaneous multi-element methods are discussed. • Other benefits of multi-line monitoring (e.g., use of an IS or LSBC) are highlighted. • Selected examples from the literature are discussed in detail

  5. Simulation of multicomponent light source for optical-electronic system of color analysis objects

    Science.gov (United States)

    Peretiagin, Vladimir S.; Alekhin, Artem A.; Korotaev, Valery V.

    2016-04-01

    Development of lighting technology has led to possibility of using LEDs in the specialized devices for outdoor, industrial (decorative and accent) and domestic lighting. In addition, LEDs and devices based on them are widely used for solving particular problems. For example, the LED devices are widely used for lighting of vegetables and fruit (for their sorting or growing), textile products (for the control of its quality), minerals (for their sorting), etc. Causes of active introduction LED technology in different systems, including optical-electronic devices and systems, are a large choice of emission color and LED structure, that defines the spatial, power, thermal and other parameters. Furthermore, multi-element and color devices of lighting with adjustable illumination properties can be designed and implemented by using LEDs. However, devices based on LEDs require more attention if you want to provide a certain nature of the energy or color distribution at all the work area (area of analysis or observation) or surface of the object. This paper is proposed a method of theoretical modeling of the lighting devices. The authors present the models of RGB multicomponent light source applied to optical-electronic system for the color analysis of mineral objects. The possibility of formation the uniform and homogeneous on energy and color illumination of the work area for this system is presented. Also authors showed how parameters and characteristics of optical radiation receiver (by optical-electronic system) affect on the energy, spatial, spectral and colorimetric properties of a multicomponent light source.

  6. COMPARISON OF METALS IN HUMAN MILK AND URINE USING TRACE MULTIELEMENT ANALYSES

    Science.gov (United States)

    Healthy, nonsmoking women from 18-38 years old twice donated milk and urine (2-7 weeks and 3-4 months postpartum) as part of the EPA's Methods Advancement for Milk Analysis study, a pilot for the National Children's Study (NCS). Our goals were to determine 1) if routine high thro...

  7. Multielement instrumental neutron activation analysis of macroalgae Cystoseira used as biomonitor of the Black Sea coastal waters pollution (South-Western Crimea, Sevastopol)

    International Nuclear Information System (INIS)

    Kravtsova, A.V.; Mil'chakova, N.A.; Frontas'eva, M.V.

    2013-01-01

    For the first time for Sevastopol region the peculiarities of 26 (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Ni, Zn, As, Br, Rb, Sr, Sb, I, Cs, Ba, Sm, Nd, Ag, Au and U) macro- and microelements accumulation in the thalli of brown algae Cystoseira from the coastal waters of south-western Crimea (the Black Sea) were studied using instrumental neutron activation analysis (INAA). The possibility of using brown algae Cystoseira as a biomonitor of coastal waters pollution was shown

  8. Timing and thermochemical constraints on multi-element mineralisation at the Nori/RA Cu-Mo-U prospect, Great Bear magmatic zone, Northwest Territories, Canada

    Science.gov (United States)

    Ootes, Luke; Goff, Steve; Jackson, Valerie A.; Gleeson, Sarah A.; Creaser, Robert A.; Samson, Iain M.; Evensen, Norman; Corriveau, Louise; Mumin, A. Hamid

    2010-08-01

    clathrates or CH4 was not observed or detected. Quartz grains only host secondary fluid inclusions, which fluoresce under ultraviolet light, indicating trapped hydrocarbons. We speculate that these resulted from Phanerozoic fluid circulation through the Proterozoic basement. The collective interpretation of the age, hydrothermal character and associated metals, high temperature and variable salinity suggests that the Nori/RA Cu-Mo-U mineralisation can be linked with the earliest stages of plutonism in the Great Bear magmatic zone. From a regional perspective, the mineralisation may pre-date the extensive multi-element mineralisation now recognised as part of the iron oxide copper-gold (IOCG) spectrum of deposits. As IOCG provinces generally contain a variety of mineralisation styles, we interpret this as the earliest phase of the extensive mineralising system.

  9. Association of glass fragments by their trace elemental content using ICP-MS and LA-ICP-MS in the analysis scheme

    Science.gov (United States)

    Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.

    2002-08-01

    The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.

  10. Otolith edge fingerprints as approach for stock identification of Genidens barbus

    Science.gov (United States)

    Avigliano, Esteban; Maichak de Carvalho, Barbara; Leisen, Mathieu; Romero, Rurik; Velasco, Gonzalo; Vianna, Marcelo; Barra, Fernando; Volpedo, Alejandra Vanina

    2017-07-01

    The purpose of this paper is to assess the use of multi-elemental otolith fingerprints as a tool to delimit catfish Genidens barbus fish stocks in four estuaries from the southwestern Atlantic Ocean. Barium:Calcium (Ca), Magnesium:Ca, Manganese:Ca, Sodium:Ca and Strontium:Ca ratios in the otolith edge were determined by LA-ICPMS. PERMANOVA analysis reveal significant differences in the multi-element signatures among estuaries (p = 0.0001-0.002). Reclassification rates of quadratic discriminant analysis are high, averaging 89.9% (78-100%). The new data presented here show that the otolith chemistry is a potential tool for stock identification, and indicates the presence of at least four stocks which should probably be handled independently.

  11. Uranium hydrogeochemical and stream sediment reconnaissance data release for the Butte NTMS Quadrangle, Montana, including concentrations of forty-two additional elements

    International Nuclear Information System (INIS)

    Broxton, D.E.; George, W.E.; Montoya, J.V.; Martell, C.J.; Hensley, W.K.; Hanks, D.

    1980-05-01

    This report contains data collected during a geochemical survey for uranium in the Butte National Topographic Map Series (NTMS) quadrangle of west-central Montana. Histograms and statistical data for uranium concentrations in water and sediment samples and thorium concentrations in sediment samples are given. Elemental concentration, field measurement, weather, geologic, and geographic data for each sample location are listed for waters and for sediments. Uranium/thorium ratios for sediment samples are also included. This report contains uranium analyses for water samples and multielement analyses for sediment samples. A supplemental report containing the results of multielement analyses of water samples will be open filed in the near future. Sediments were analyzed for uranium and thorium as well as aluminum, antimony, barium, beryllium, bismuth, cadmium, calcium, cerium, cesium, chlorine, chromium, cobalt, copper, dysprosium, europium, gold, hafnium, iron, lanthanum, lead, lithium, lutetium, magnesium, manganese, nickel, niobium, potassium, rubidium, samarium, scandium, silver, sodium, strontium, tantalum, terbium, tin, titanium, tungsten, vanadium, ytterbium, and zinc. All elemental analyses were performed at the LASL. Water samples were initially analyzed for uranium by fluorometry. All water samples containing more than 40 ppB uranium were reanalyzed by delayed-neutron counting (DNC). All sediments were analyzed for uranium by DNC. Other elemental concentrations in sediments were determined by neutron activation analysis for 31 elements, by x-ray fluorescence for 9 elements, and by arc-source emission spectrography for 2 elements. Analytical results for sediments are reported as parts per million. Descriptions of procedures used for analysis of water and sediment samples as well as analytical precisions and detection limits are given

  12. Quality control and performance evaluation of k0-based neutron activation analysis at the Portuguese research reactor

    International Nuclear Information System (INIS)

    Dung, H.M.; Freitas, M.C.; Blaauw, M.; Almeida, S.M.; Dionisio, I.; Canha, N.H.

    2010-01-01

    The quality control (QC) and performance evaluation for the k 0 -based neutron activation analysis (k 0 -NAA) at the Portuguese research reactor (RPI) has been developed with the intention of using the method to meet the demands of trace element analysis for the applications in environmental, epidemiological and nutritional studies amongst others. The QC and performance evaluation include the following aspects: (1) estimation of the overall/combined standard uncertainty from the primary uncertainty sources; (2) validation of the method using a synthetic multi-element standard (SMELS); and (3) analysis of the certified reference materials from the National Institute of Standards and Technology (USA): NIST-SRM-1633a and NIST-SRM-1648 and the reference material from the International Atomic Energy Agency: IAEA-RM-336, for the purpose of controlling the overall accuracy and precision of the analytical results. The obtained results revealed that the k 0 -NAA method established at the RPI was fit for the purpose. The overall/combined standard uncertainty was estimated for elements of interest in the intended applications. The laboratory's analytical results as compared to the assigned values with the bias were less than 12% for most elements, except for a few elements which biased within 13-18%. The u-score values for most elements were less than |1.64|, except for Co, La and Ti within |1.64|-|1.96| and Sc, Cr, K and Sb within |1.96|-|2.58|. The NIST-1633a was also analyzed over 14 months for the purpose of evaluating the reproducibility of the method. The quality factors of k 0 -NAA established at RPI were evaluated, proving that the method meets the requirements of trace element analysis, which is also considering the method's performance for which the k 0 -NAA affords a specific, rapid and convenient capability for the intended applications.

  13. Epithermal Neutron Activation Analysis of the Asian Herbal Plants

    International Nuclear Information System (INIS)

    Baljinnyam, N.; Frontasyeva, M. V.; Ostrovnaya, T. M.; Pavlov, S. S.; Jugder, B.; Norov, N.

    2011-01-01

    Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

  14. Recent development of radioanalytical method at IBR-2 pulsed fast reactor of the JINR

    International Nuclear Information System (INIS)

    Nazarov, V.M.; Pavlov, S.S.; Herrera, E.

    1991-01-01

    The experience of the use of radioanalytical methods, including NAA at IBR-2 pilsed fast reactor of the JINR, is discussed. Physical and technical parameters of the experimental installation designed for NAA and radiography are given. The detailed examples of the application of resonance neutrons to the control of the environment in the geology of oil, in multi-element analysis of food products and superpure materials as well as in nuclear physics are reviewed. The works on the application of the neutron isotopes sources for express determination of nitrogen content in original and synthetic materials are introduced. 7 refs.; 8 figs.; 3 tabs

  15. ITRA 084 - a microprocessor controlled rapid analyzer in mining and metallurgy

    International Nuclear Information System (INIS)

    Kliem, V.; Kreher, M.; Boy, N.

    1986-01-01

    A new rapid analyzer of the ITRA series has been developed at the Freiberg Research Institute of Non-Ferrous Metals for single and multi-element analysis in mining and non-ferrous metallurgy. INTRA-08 represents an efficient microprocessor-controlled on-line X-ray fluorescence analyzer based on the main principles utilized with success hitherto in device engineering (isotope excitation, four-channel modification, balance filter method). A U880 single-chip microcomputer provides the central control of the device including the execution of an extensive program for the matrix correction. The efficiency of the analyzer is demonstrated taking measured values as a basis

  16. An evaluation of inductively coupled plasma optical emission spectrometry using electrothermal atomisation sample introduction and photographic plate detection

    International Nuclear Information System (INIS)

    Khathing, D.T.; Pickford, C.J.

    1984-05-01

    A photographic radiation measurement approach has been used with an inductively coupled plasma source to evaluate and tabulate the more prominent optical emission lines of 66 elements. Compared with the more common sample introduction technique using nebulisation, increased sensitivity for multielement analysis of small samples was achieved by using a simple graphite electrothermal atomisation system. This was constructed to serve as a dual purpose atomiser ie both for Atomic Absorption and for Inductively Coupled Plasma Emission spectroscopy. The system offers the advantage of a wide multi-elemental coverage, but sensitivities achieved with photographic detection are poorer than those obtained photoelectrically. (author)

  17. Determination of light rare earths and other elements in Cuban soils

    International Nuclear Information System (INIS)

    Lam Ramos, P.; Frias Fonseca, D.J.; Gonzalez Garcia, M.A.; Aguiar Lambert, D.E.; Estevez Alvarez, J.R.; Pupo Gonzalez, I.; Lopez Sanchez, D.R.

    2001-01-01

    The objective of the present study was the elaboration of a procedure for the determination of Y, La, Ce, Pr and Nd in soils by spectrophotometry with Arsenazo III preceded by a separation-concentration stage, which includes coprecipitation and ion exchange. Multielement analysis by energy dispersive X-ray fluorescence (including Y, La, Ce and Nd) and flame atomic absorption spectrophotometry was carried out simultaneously in order to obtain a general characterization of the soil samples. Certified reference materials and statistical intercomparison of the obtained results were used to evaluate the accuracy of the methods. The precision was examined by analyzing replicate samples. (author)

  18. Detectable elements in a particles pattern of suspended urban matter analysed by neutron activation

    International Nuclear Information System (INIS)

    Herrera, L.; Beltran, C.; Alemon, E.; Ortiz, M.E.

    2001-01-01

    The multielement composition of a Standard Reference Material 1648 pattern certified is reported and it is used for the suspended in air aerosol samples analysis from urban localities of the Valley of Mexico, which was irradiated in the same geometry of the sample. The bottom of laboratory is analysed where was made the gamma spectrometry and it is compared the ratio of country up of bottom photo peaks with pattern photo peaks in nearer interest regions. The bottom natural gamma transmitters were identified and those of the activated pattern in the TRIGA Mark III nuclear reactor. (Author)

  19. Determination of the rare earth elements in marine pore waters and associated sediments

    International Nuclear Information System (INIS)

    Kennedy, H.; Elderfield, H.

    Accurate and precise determinations of natural levels of rare earth elements (R.E.E.) in sea water and pore water are highly reliant upon the size and variability of the analytical blank, the method for determining the yield, and, to a lesser extent, the inherent precision of the instrument used. Isotope dilution mass spectrometry (IDMS) together with ultra-clean room techniques has been successfully used in the determinations of rare earth elements in pore waters. Simultaneous multi-element analysis by inductively coupled plasma atomic emission spectrometry (ICP) provides an alternative to IDMS for a rapid determination of R.E.E. in sediments. (author)

  20. Evaluation of the k0 method by its application to (n, γ)RNaa of geological, environmental and clay reference materials

    International Nuclear Information System (INIS)

    Corte, F. de; Lin Xilei; Moens, L.; Wispelaere, A. de; Hoste, J.; Demeter, A.; Simonits, A.

    1984-01-01

    The k 0 standardization method, the state-of-the-art of which is shortly reviewed, has been applied to multi-element reactor neutron activation analysis of (standard) reference materials. The analyses have been performed independently at the Institute for Nuclear Sciences (Gent, Belgium) and the Central Research Institute for Physics (Budapest, Hungary). Results are given for USGS-2 (granite), NBS SRM-1633a (coal fly ash) and FCG (fired clay of Gent). Comparison with literature data shows that the k 0 method, while being experimentally simple, versatile and suited for computerization, offers a potential accuracy of better than 5%. (author)

  1. Application of epithermal neutron activation in multielement analysis of silicate rocks employing both coaxial Ge(Li) and low energy photon detector systems

    Science.gov (United States)

    Baedecker, P.A.; Rowe, J.J.; Steinnes, E.

    1977-01-01

    The instrumental activation analysis of silicate rocks using epithermal neutrons has been studied using both high resolution coaxial Ge(Li) detectors and low energy photon detectors, and applied to the determination of 23 elements in eight new U.S.G.S. standard rocks. The analytical use X-ray peaks associated with electron capture or internal conversion processes has been evaluated. Of 28 elements which can be considered to be determinable by instrumental means, the epithermal activation approach is capable of giving improved sensitivity and precision in 16 cases, over the normal INAA procedure. In eleven cases the use of the low energy photon detector is thought to show advantages over convertional coaxial Ge(Li) spectroscopy. ?? 1977 Akade??miai Kiado??.

  2. Neutron activation analysis of trace elements in rain water

    International Nuclear Information System (INIS)

    Luten, J.B.

    1977-01-01

    In this thesis the principles and practical aspects of activation analysis which are of direct importance in the analysis of rain water, are presented together with recent literature data on other techniques. Problems due to the storage of rain water samples are discussed. A multi-element method for the determination of trace elements in rain water by instrumental neutron activation analysis is described. Gamma ray spectrometry using Ge(Li) detectors offers the possibility to determine Na, Al, Cl, V, Mn, Co, Cu, Br and I in rain water samples of 2.5 ml after a 4-min irradiation in a thermal neutron flux of 5 x 10 13 n cm -2 s -1 . In residues of rain water samples of 100 ml, irradiated during 2 days in a thermal neutron flux of >5 x 10 13 n cm -2 s -1 Cr, Fe, Co, Zn and Sb can be determined after a cooling period of approximately 21 days. The detection limits are lower than those reported in previous investigations except for Cu. The precision is about 10% or better, except for Co, Cu and I. A routine method for the determination of bromine and iodine in rain water by n.a.a. is presented. The elements are isolated by isotope exchange between the irradiated sample and a solution of Br 2 or I 2 in CCl 4 . The method is not sensitive to the chemical species in which the halogen is present. Irradiation of solutions of iodine compounds in a high thermal neutron flux gives rise to the formation of iodate. Results of a further investigation of this phenomenon are given, as well as the determination of iodate in rain water by n.a.a. Iodate is separated by anion exchange. The combination of n.a.a. and solvent extraction is used for the determination of five trace elements (V, Co, Cu, Zn and In) in 10-ml rain water samples. For V, Co and Cu this method is more sensitive and reproducible than instrumental n.a.a. The results of the analysis of eleven sequential 30-ml samples from the beginning of the shower are presented as an illustration of possible applications of the

  3. Statistical Characterization of Electromagnetic Wave Propagation in Mine Environments

    KAUST Repository

    Yucel, Abdulkadir C.; Liu, Yang; Bagci, Hakan; Michielssen, Eric

    2013-01-01

    A computational framework for statistically characterizing electromagnetic (EM) wave propagation through mine tunnels and galleries is presented. The framework combines a multi-element probabilistic collocation method with a full-wave fast Fourier

  4. Collection of airborne particulate matter for a subsequent analysis by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von; Schmeling, M.; Klockow, D.

    1995-01-01

    The collection of airborne particulate matter by filtration and impaction was adapted to total reflection X-ray fluorescence analysis (TXRF). Cellulose nitrate filters were used for collecting in a Berner impactor. Single filter spots were punched out, placed on quartz-glass carriers, dissolved by tetrahydrofuran and re-precipitated prior to element determinations by TXRF. In a Battelle-type impactor, airborne dust was collected on Plexiglass carriers coated with medical Vaseline. The loaded carriers were directly analyzed by TXRF. In both cases, quantification was simply performed by the addition of an internal standard after sampling. Impactors were made of a suitable material in order to investigate high blank values, collection losses and memory effects. It could be shown that stainless steel, even coated with TiN, is less suitable and should be avoided as an impactor material. Although aluminum is partly recommendable, titanium and the polymer Makrolon are quite appropriate. By using an impactor made of these materials, a reliable multielement determination in airborne dust is made possible with low detection limits as low as 1 ng/m 3 and a satisfactory repeatability of a few %. Short sampling times of only 1 h or less can be realized. The total procedure is simple and time-saving, and can be recommended for routine investigations of airborne particulate matter. (author)

  5. Total mass difference statistics algorithm: a new approach to identification of high-mass building blocks in electrospray ionization Fourier transform ion cyclotron mass spectrometry data of natural organic matter.

    Science.gov (United States)

    Kunenkov, Erast V; Kononikhin, Alexey S; Perminova, Irina V; Hertkorn, Norbert; Gaspar, Andras; Schmitt-Kopplin, Philippe; Popov, Igor A; Garmash, Andrew V; Nikolaev, Evgeniy N

    2009-12-15

    The ultrahigh-resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrum of natural organic matter (NOM) contains several thousand peaks with dozens of molecules matching the same nominal mass. Such a complexity poses a significant challenge for automatic data interpretation, in which the most difficult task is molecular formula assignment, especially in the case of heavy and/or multielement ions. In this study, a new universal algorithm for automatic treatment of FTICR mass spectra of NOM and humic substances based on total mass difference statistics (TMDS) has been developed and implemented. The algorithm enables a blind search for unknown building blocks (instead of a priori known ones) by revealing repetitive patterns present in spectra. In this respect, it differs from all previously developed approaches. This algorithm was implemented in designing FIRAN-software for fully automated analysis of mass data with high peak density. The specific feature of FIRAN is its ability to assign formulas to heavy and/or multielement molecules using "virtual elements" approach. To verify the approach, it was used for processing mass spectra of sodium polystyrene sulfonate (PSS, M(w) = 2200 Da) and polymethacrylate (PMA, M(w) = 3290 Da) which produce heavy multielement and multiply-charged ions. Application of TMDS identified unambiguously monomers present in the polymers consistent with their structure: C(8)H(7)SO(3)Na for PSS and C(4)H(6)O(2) for PMA. It also allowed unambiguous formula assignment to all multiply-charged peaks including the heaviest peak in PMA spectrum at mass 4025.6625 with charge state 6- (mass bias -0.33 ppm). Application of the TMDS-algorithm to processing data on the Suwannee River FA has proven its unique capacities in analysis of spectra with high peak density: it has not only identified the known small building blocks in the structure of FA such as CH(2), H(2), C(2)H(2)O, O but the heavier unit at 154.027 amu. The latter was

  6. Modeling 3D-CSIA data: Carbon, chlorine, and hydrogen isotope fractionation during reductive dechlorination of TCE to ethene.

    Science.gov (United States)

    Van Breukelen, Boris M; Thouement, Héloïse A A; Stack, Philip E; Vanderford, Mindy; Philp, Paul; Kuder, Tomasz

    2017-09-01

    Reactive transport modeling of multi-element, compound-specific isotope analysis (CSIA) data has great potential to quantify sequential microbial reductive dechlorination (SRD) and alternative pathways such as oxidation, in support of remediation of chlorinated solvents in groundwater. As a key step towards this goal, a model was developed that simulates simultaneous carbon, chlorine, and hydrogen isotope fractionation during SRD of trichloroethene, via cis-1,2-dichloroethene (and trans-DCE as minor pathway), and vinyl chloride to ethene, following Monod kinetics. A simple correction term for individual isotope/isotopologue rates avoided multi-element isotopologue modeling. The model was successfully validated with data from a mixed culture Dehalococcoides microcosm. Simulation of Cl-CSIA required incorporation of secondary kinetic isotope effects (SKIEs). Assuming a limited degree of intramolecular heterogeneity of δ 37 Cl in TCE decreased the magnitudes of SKIEs required at the non-reacting Cl positions, without compromising the goodness of model fit, whereas a good fit of a model involving intramolecular CCl bond competition required an unlikely degree of intramolecular heterogeneity. Simulation of H-CSIA required SKIEs in H atoms originally present in the reacting compounds, especially for TCE, together with imprints of strongly depleted δ 2 H during protonation in the products. Scenario modeling illustrates the potential of H-CSIA for source apportionment. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Development of a portable system of grazing exit X-Ray fluorescence applied to environmental and biological studies

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Ramon S.; Oliveira, Davi F.; Anjos, Marcelino J. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Instituto de Fisica; Assis, Joaquim T., E-mail: ramonziosp@yahoo.com.br, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br, E-mail: joaquim.iprj@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil). Instituto Politécnico

    2017-07-01

    In this study was developed a portable system of grazing exit X-ray fluorescence (geometric 90° - 0°) that will be applied in environmental studies (aerosol samples) and biological studies. GE-XRF portable system is formed by a mini X-ray tube of low power (anode of Au, maximum voltage and current of 50 kV and 200 μA, respectively) and a SiPIN detector (model XR-100CR of the Amptek). The reflectors used as sample support (sampler carrier) were quartz discs with 25.4 mm diameter and 3.0 mm thickness. The grazing exit angle was experimentally determined by measuring a cooper solution (10 μg.g{sup -1}). The system of GE-XRF proved to be quite stable and reproducible. It was calculated the sensibility curve of the system using multielement solutions. The accuracy of the system was checked using multielement reference solution as standard reference material. The relative errors between measured and certified values are in the range of 4 to 19%. The first results showed a background was drastically reduced at grazing exit angles, enabling trace elemental analysis. This paper shows that it is possible to produce a portable system of grazing exit X-ray fluorescence compact, efficient, low-cost and easy-to-handle instrumentation using a low-power X-ray tube and a SiPIN compact detector. (author)

  8. Laser-induced breakdown spectroscopy fundamentals and applications

    CERN Document Server

    Noll, Reinhard

    2012-01-01

    This book is a comprehensive source of the fundamentals, process parameters, instrumental components and applications of laser-induced breakdown spectroscopy (LIBS). The effect of multiple pulses on material ablation, plasma dynamics and plasma emission is presented. A heuristic plasma modeling allows to simulate complex experimental plasma spectra. These methods and findings form the basis for a variety of applications to perform quantitative multi-element analysis with LIBS. These application potentials of LIBS have really boosted in the last years ranging from bulk analysis of metallic alloys and non-conducting materials, via spatially resolved analysis and depth profiling covering measuring objects in all physical states: gaseous, liquid and solid. Dedicated chapters present LIBS investigations for these tasks with special emphasis on the methodical and instrumental concepts as well as the optimization strategies for a quantitative analysis. Requirements, concepts, design and characteristic features of LI...

  9. [Progress in the application of laser ablation ICP-MS to surface microanalysis in material science].

    Science.gov (United States)

    Zhang, Yong; Jia, Yun-hai; Chen, Ji-wen; Shen, Xue-jing; Liu, Ying; Zhao, Leiz; Li, Dong-ling; Hang, Peng-cheng; Zhao, Zhen; Fan, Wan-lun; Wang, Hai-zhou

    2014-08-01

    In the present paper, apparatus and theory of surface analysis is introduced, and the progress in the application of laser ablation ICP-MS to microanalysis in ferrous, nonferrous and semiconductor field is reviewed in detail. Compared with traditional surface analytical tools, such as SEM/EDS (scanning electron microscopy/energy dispersive spectrum), EPMA (electron probe microanalysis analysis), AES (auger energy spectrum), etc. the advantage is little or no sample preparation, adjustable spatial resolution according to analytical demand, multi-element analysis and high sensitivity. It is now a powerful complementary method to traditional surface analytical tool. With the development of LA-ICP-MS technology maturing, more and more analytical workers will use this powerful tool in the future, and LA-ICP-MS will be a super star in elemental analysis field just like LIBS (Laser-induced breakdown spectroscopy).

  10. A multi-element psychosocial intervention for early psychosis (GET UP PIANO TRIAL) conducted in a catchment area of 10 million inhabitants: study protocol for a pragmatic cluster randomized controlled trial.

    Science.gov (United States)

    Ruggeri, Mirella; Bonetto, Chiara; Lasalvia, Antonio; De Girolamo, Giovanni; Fioritti, Angelo; Rucci, Paola; Santonastaso, Paolo; Neri, Giovanni; Pileggi, Francesca; Ghigi, Daniela; Miceli, Maurizio; Scarone, Silvio; Cocchi, Angelo; Torresani, Stefano; Faravelli, Carlo; Zimmermann, Christa; Meneghelli, Anna; Cremonese, Carla; Scocco, Paolo; Leuci, Emanuela; Mazzi, Fausto; Gennarelli, Massimo; Brambilla, Paolo; Bissoli, Sarah; Bertani, Maria Elena; Tosato, Sarah; De Santi, Katia; Poli, Sara; Cristofalo, Doriana; Tansella, Michele; Ruggeri, Mirella; Mirella, Maria Elena; Bissoli, Sarah; Bonetto, Chiara; Cristofalo, Doriana; De Santi, Katia; Lasalvia, Antonio; Lunardi, Silvia; Negretto, Valentina; Poli, Sara; Tosato, Sarah; Zamboni, Maria Grazia; Ballarin, Mario; De Girolamo, Giovanni; Fioritti, Angelo; Neri, Giovanni; Pileggi, Francesca; Rucci, Paola; Bocchio Chiavetto, Luisella; Scasselatti, Catia; Zanardini, Roberta; Brambilla, Paolo; Bellani, Marcella; Bertoldo, Alessandra; Marinelli, Veronica; Negretto, Valentina; Perlini, Cinzia; Rambaldelli, Gianluca; Lasalvia, Antonio; Bertani, Mariaelena; Bissoli, Sarah; Lazzarotto, Lorenza; Bardella, Sonia; Gardellin, Francesco; Lamonaca, Dario; Lasalvia, Antonio; Lunardon, Marco; Magnabosco, Renato; Martucci, Marilena; Nicolau, Stylianos; Nifosì, Francesco; Pavanati, Michele; Rossi, Massimo; Piazza, Carlo; Piccione, Gabriella; Sala, Alessandra; Sale, Annalisa; Stefan, Benedetta; Zotos, Spyridon; Balbo, Mirko; Boggian, Ileana; Ceccato, Enrico; Dall'Agnola, Rosa; Gardellin, Francesco; Girotto, Barbara; Goss, Claudia; Lamonaca, Dario; Lasalvia, Antonio; Leoni, Roberta; Mai, Alessia; Pasqualini, Annalisa; Pavanati, Michele; Piazza, Carlo; Piccione, Gabriella; Roccato, Stefano; Rossi, Alberto; Sale, Annalisa; Strizzolo, Stefania; Zotos, Spyridon; Urbani, Anna; Ald, Flavia; Bianchi, Barbara; Cappellari, Paola; Conti, Raffaello; De Battisti, Laura; Lazzarin, Ermanna; Merlin, Silvia; Migliorini, Giuseppe; Pozzan, Tecla; Sarto, Lucio; Visonà, Stefania; Brazzoli, Andrea; Campi, Antonella; Carmagnani, Roberta; Giambelli, Sabrina; Gianella, Annalisa; Lunardi, Lino; Madaghiele, Davide; Maestrelli, Paola; Paiola, Lidia; Posteri, Elisa; Viola, Loretta; Zamberlan, Valentina; Zenari, Marta; Tosato, Sarah; Zanoni, Martina; Bonadonna, Giovanni; Bonomo, Mariacristina; Santonastaso, Paolo; Cremonese, Carla; Scocco, Paolo; Veronese, Angela; Anderle, Patrizia; Angelozz, Andrea; Amalric, Isabelle; Baron, Gabriella; Candeago, Enrico Bruttomesso Fabio; Castelli, Franco; Chieco, Maria; Cremonese, Carla; Di Costanzo, Enrico; Derossi, Mario; Doriguzzi, Michele; Galvano, Osvaldo; Lattanz, Marcello; Lezzi, Roberto; Marcato, Marisa; Marcolin, Alessandro; Marini, Franco; Matranga, Manlio; Scalabrin, Donato; Zucchetto, Maria; Zadro, Flavio; Austoni, Giovanni; Bianco, Maria; Bordino, Francesca; Dario, Filippo; De Risio, Alessandro; Gatto, Aldo; Granà, Simona; Favero, Emanuele; Franceschin, Anna; Friederici, Silvia; Marangon, Vanna; Pascolo, Michela; Ramon, Luana; Scocco, Paolo; Veronese, Angela; Zambolin, Stefania; Riolo, Rossana; Buffon, Antonella; Cremonese, Carla; Di Bortolo, Elena; Friederici, Silvia; Fortin, Stefania; Marcato, Marisa; Matarrese, Francesco; Mogni, Simona; Codemo, Novella; Russi, Alessio; Silvestro, Alessandra; Turella, Elena; Viel, Paola; Dominoni, Anna; Andreose, Lorenzo; Boemio, Mario; Bressan, Loretta; Cabbia, Arianna; Canesso, Elisabetta; Cian, Romina; Dal Piccol, Claudia; Dalla Pasqua, Maria Manuela; Di Prisco, Anna; Mantellato, Lorena; Luison, Monica; Morgante, Sandra; Santi, Mirna; Sacillotto, Moreno; Scabbio, Mauro; Sponga, Patrizia; Sguotto, M Luisa; Stach, Flavia; Vettorato, M Grazia; Martinello, Giorgio; Dassiè, Francesca; Marino, Stefano; Cibiniel, Linda; Masetto, Ilenia; Marcato, Marisa; Cabianca, Oscar; Valente, Amalia; Caberlotto, Livio; Passoni, Alberto; Flumian, Patrizia; Daniel, Luigino; Gion, Massimo; Stanziale, Stanziale; Alborino, Flora; Bortolozzo, Vladimiro; Bacelle, Lucio; Bicciato, Leonarda; Basso, Daniela; Navaglia, Filippo; Manoni, Fabio; Ercolin, Mauro; Neri, Giovanni; Giubilini, Franco; Imbesi, Massimiliano; Leuci, Emanuela; Mazzi, Fausto; Semrov, Enrico; Giovanni, Castel S; Taro e Ceno, Valli; Ovest, Polo; Anelli, Silvio; Amore, Mario; Bigi, Laura; Britta, Welsch; Anna, Giovanna Barazzoni; Bonatti, Uobes; Borziani, Maria; Crosato, Isabella; Galluccio, Raffaele; Galeotti, Margherita; Gozzi, Mauro; Greco, Vanna; Guagnini, Emanuele; Pagani, Stefania; Maccherozzi, Malvasi; Marchi, Francesco; Melato, Ermanno; Mazzucchi, Elena; Marzullo, Franco; Pellegrini, Pietro; Petrolini, Nicoletta; Volta, Paolo; Anelli, Silvio; Bonara, Franca; Brusamonti, Elisabetta; Croci, Roberto; Flamia, Ivana; Fontana, Francesca; Losi, Romina; Mazzi, Fausto; Marchioro, Roberto; Pagani, Stefania; Raffaini, Luigi; Ruju, Luca; Saginario, Antonio; Tondelli, M Grazia; Marrama, Donatella; Bernardelli, Lucia; Bonacini, Federica; Florindo, Annaluisa; Merli, Marina; Nappo, Patrizia; Sola, Lorena; Tondelli, Ornella; Tonna, Matteo; Torre, M Teresa; Tosatti, Morena; Venturelli, Gloria; Zampolla, Daria; Bernardi, Antonia; Cavalli, Cinzia; Cigala, Lorena; Ciraudo, Cinzia; Di Bari, Antonia; Ferri, Lorena; Gombi, Fabiana; Leurini, Sonia; Mandatelli, Elena; Maccaferri, Stefano; Oroboncoide, Mara; Pisa, Barbara; Ricci, Cristina; Poggi, Enrica; Zurlini, Corrado; Malpeli, Monica; Colla, Rossana; Teodori, Elvira; Vecchia, Luigi; D'Andrea, Rocco; Trenti, Tommaso; Paolini, Paola; Mazzi, Fausto; Carpeggiani, Paolo; Pileggi, Francesca; Ghigi, Daniela; Gagliostro, Mariateresa; Pratelli, Michela; Rucci, Paola; Lazzaro, S; Antonelli, Antonio; Battistini, Luana; Bellini, Francesca; Bonini, Eva; Capelli, Caterina Bruschi Rossella; DiDomizio, Cinzia; Drei, Chiara; Fucci, Giuseppe; Gualandi, Alessandra; Grazia, Maria Rosaria; Losi, Anna M; Mazzoni, Federica Mazzanti Paola; Marangoni, Daniela; Monna, Giuseppe; Morselli, Marco; Oggioni, Alessandro; Oprandi, Silvio; Paganelli, Walter; Passerini, Morena; Piscitelli, Maria; Reggiani, Gregorio; Rossi, Gabriella; Salvatori, Federica; Trasforini, Simona; Uslenghi, Carlo; Veggetti, Simona; Bartolucci, Giovanna; Baruffa, Rosita; Bellini, Francesca; Bertelli, Raffaella; Borghi, Lidia; Ciavarella, Patrizia; DiDomizio, Cinzia; Monna, Giuseppe; Oggioni, Alessandro; Paltrinieri, Elisabetta; Rizzardi, Francesco; Serra, Piera; Suzzi, Damiano; Carlo, Uslenghi; Piscitelli, Maria; Arienti, Paolo; Aureli, Fabio; Avanzi, Rosita; Callegari, Vincenzo; Corsino, Alessandra; Host, Paolo; Michetti, Rossella; Pratelli, Michela; Rizzo, Francesco; Simoncelli, Paola; Soldati, Elena; Succi, Eraldo; Bertozzi, Massimo; Canetti, Elisa; Cavicchioli, Luca; Ceccarelli, Elisa; Cenni, Stefano; Marzola, Glenda; Gallina, Vanessa; Leoni, Carla; Olivieri, Andrea; Piccolo, Elena; Ravagli, Sabrina; Russo, Rosaria; Tedeschini, Daniele; Verenini, Marina; Abram, Walter; Granata, Veronica; Curcio, Alessandro; Guerra, Giovanni; Granini, Samuela; Natali, Lara; Montanari, Enrica; Pasi, Fulvia; Ventura, Umbertina; Valenti, Stefania; Francesca, Masi; Farneti, Rossano; Ravagli, Paolo; Floris, Romina; Maroncelli, Otello; Volpones, Gianbattista; Casali, Donatella; Miceli, Maurizio; Bencini, Andrea; Cellini, Massimo; De Biase, Luca; Barbara, Leonardo; Charles, Liedl; Pratesi, Cristina; Tanini, Andrea; Cellini, Massimo; Miceli, Maurizio; Loparrino, Riccardo; Pratesi, Cristina; Ulivelli, Cinzia; Cussoto, Cristina; Dei, Nico; Fumanti, Enrico; Pantani, Manuela; Zeloni, Gregorio; Bellini, Rossella; Cellesi, Roberta; Dorigo, Nadia; Gullì, Patrizia; Ialeggio, Luisa; Pisanu, Maria; Rinaldi, Graziella; Konze, Angela; Cocchi, Angelo; Meneghelli, Anna; Bianco, Mario; Modignani, Litta; Frova, Maria; Monzani, Emiliano; Zanobio, Alberto; Malagoli, Marina; Pagani, Roberto; Barbera, Simona; Morganti, Carla; Monzani, Emiliano; Amadè, Elisabetta Sarzi; Brambilla, Virginia; Montanari, Anita; Caterina, Giori; Lopez, Carmelo; Marocchi, Alessandro; Moletta, Andrea; Sberna, Maurizio; Cascio, M Teresa; Scarone, Silvio; Manzone, Maria Laura; Barbara, Barbera; Mari, Luisa; Manzone, Maria L; Razzini, Edoardo; Bianchi, Yvonne; Pellizzer, M Rosa; Verdecchia, Antonella; Sferrazza, M Gabriella; Manzone, M Laura; Pismataro, Rosa; D'Eril, Gian Vico Melzi; Barassi, Alessandra; Pacciolla, Rosana; Faraci, Gloria; Torresani, Stefano; Rosmini, Bolzano; Carpi, Fabio; Soelva, Margit; Anderlan, Monica; De Francesco, Michele; Duregger, Efi; Torresani, Stefano; Vettori, Carla; Doimo, Sabrina; Kompatscher, Erika; Soelva, Margit; Torresani, Stefano; Forer, Michael; Kerschbaumer, Helene; Gampe, Anna; Nicoletti, Maira; Acerbi, Chiara; Aquilino, Daniele; Azzali, Silvia; Bensi, Luca; Bissoli, Sarah; Cappellari, Davide; Casana, Elisa; Campagnola, Nadia; Dal Corso, Elisa; Di Micco, Elisabetta; Gobbi, Erika; Ferri, Laura; Gobbi, Erika; Mairaghi, Laura; Malak, Sara; Mesiano, Luca; Paterlini, Federica; Perini, Michela; Puliti, Elena Maria; Rispoli, Rosaria; Rizzo, Elisabetta; Sergenti, Chiara; Soave, Manuela; Alpi, Andrea; Bislenghi, Laura; Bolis, Tiziana; Colnaghi, Francesca; Fascendini, Simona; Grignani, Silvia; Meneghelli, Anna; Patelli, Giovanni; Faravelli, Carlo; Casale, Silvia; Zimmermann, Christa; Deledda, Giuseppe; Goss, Claudia; Mazzi, Mariangela; Rimondini, Michela; Gennarelli, Massimo; Scassellati, Catia; Bonvicini, Cristian; Longo, Sara; Bocchio Chiavetto, Luisella; Zanardini, Roberta; Ventriglia, Mariacarla; Squitti, Rosanna; Frisoni, Giovanni; Pievani, Michela; Balestrieri, Matteo; Brambilla, Paolo; Perlini, Cinzia; Marinelli, Veronica; Bellani, Marcella; Rambaldelli, Gianluca; Bertoldo, Alessandra; Atzori, Manfredo; Mazzi, Fausto; Carpeggiani, Paolo; Beltramello, Alberto; Alessandrini, Franco; Pizzini, Francesca; Zoccatelli, Giada; Sberna, Maurizio; Konze, Angela; Politi, Pierluigi; Emanuele, Enzo; Brondino, Natascia; Martino, Gianvito; Bergami, Alessandra; Zarbo, Roberto; Riva, Marco Andrea; Fumagalli, Fabio; Molteni, Raffaella; Calabrese, Francesca; Guidotti, Gianluigi; Luoni, Alessia; Macchi, Flavia; Artioli, Stefania; Baldetti, Marco; Bizzocchi, Milena; Bolzon, Donatella; Bonello, Elisa; Cacciari, Giorgia; Carraresi, Claudia; Cascio, M Teresa; Caselli, Gabriele; Furlato, Karin; Garlassi, Sara; Gavarini, Alessandro; Lunardi, Silvia; Macchetti, Fabio; Marteddu, Valentina; Plebiscita, Giorgia; Poli, Sara; Totaro, Stefano; Bebbington, Paul; Birchwood, Max; Dazzan, Paola; Kuipers, Elisabeth; Thornicroft, Graham; Pariante, Carmine; Lawrie, Steve; Pariante, Carmine; Soares, Jair C

    2012-05-30

    Multi-element interventions for first-episode psychosis (FEP) are promising, but have mostly been conducted in non-epidemiologically representative samples, thereby raising the risk of underestimating the complexities involved in treating FEP in 'real-world' services. The Psychosis early Intervention and Assessment of Needs and Outcome (PIANO) trial is part of a larger research program (Genetics, Endophenotypes and Treatment: Understanding early Psychosis - GET UP) which aims to compare, at 9 months, the effectiveness of a multi-component psychosocial intervention versus treatment as usual (TAU) in a large epidemiologically based cohort of patients with FEP and their family members recruited from all public community mental health centers (CMHCs) located in two entire regions of Italy (Veneto and Emilia Romagna), and in the cities of Florence, Milan and Bolzano. The GET UP PIANO trial has a pragmatic cluster randomized controlled design. The randomized units (clusters) are the CMHCs, and the units of observation are the centers' patients and their family members. Patients in the experimental group will receive TAU plus: 1) cognitive behavioral therapy sessions, 2) psycho-educational sessions for family members, and 3) case management. Patient enrollment will take place over a 1-year period. Several psychopathological, psychological, functioning, and service use variables will be assessed at baseline and follow-up. The primary outcomes are: 1) change from baseline to follow-up in positive and negative symptoms' severity and subjective appraisal; 2) relapse occurrences between baseline and follow-up, that is, episodes resulting in admission and/or any case-note records of re-emergence of positive psychotic symptoms. The expected number of recruited patients is about 400, and that of relatives about 300. Owing to the implementation of the intervention at the CMHC level, the blinding of patients, clinicians, and raters is not possible, but every effort will be made

  11. Research activities in the fields of radiochemistry and neutron activation analysis using the LENA nuclear plant in Pavia

    International Nuclear Information System (INIS)

    Maggi, L.; Genova, N.; DiCasa, M.; Carmella-Crespi, V.

    1978-01-01

    In the past two years the activity of the Radiochemistry Laboratory and CNR Centre of Radiochemistry and Activation Analysis was mainly devoted to studies of nuclear activation analysis applied to different fields using the LENA reactor. Three NBS vegetable reference standards, Orchard Leaves, Tomato Leaves and Pine Needles, were analyzed for their halogen content. Halogen determination in foodstuff, vegetables and organic tissues gives valuable information on metabolic, nutritional, pollution and epidemiological fields. A detailed study on macro- and micro-elements content in Sardinian coal and its ashes was performed, in order to assess the possibility of using it as a fuel in electric power generating plants. Instrumental neutron activation analysis was used for the determination of Al, Si, Mn, Mg, Na, V, CI, Ce, Yb, Th, Cr, Hf, Cs, Se, Rb, Fe, Co, Ta, Eu, K, La and Sb. A multielement trace analysis of rock samples was developed in cooperation with scientists from other Universities; the determination of R.E., U, Th, Zr, Cs, Ba, Ni, Sc, Ta, Hf, Sr, and Cr by instrumental neutron activation analysis was carried out in connection with orogenetic studies of African Rocks. In the archaeological field ancient artefacts recently discovered during a digging campaign at Monza's Cathedral (Italy) were analyzed with the aim to trace their origin and compare their composition with similar samples whose dating is certain. As a contribute to the international program of certifying NBS reference standard materials, chromium in the Brewer's Yeast, recently proposed as a new SRM, was determined by both instrumental and destructive neutron activation analysis. In the study of the role and behaviour of trace elements in human physiology, vanadium was investigated in human blood, as a trace element of increasing interest in connection with its origin from pollutants. Nuclear activation analysis was also applied to marine organism samples under a contract for oceanographic research

  12. Modelling nonstationary thermohydrodynamic processes in heat-exchange circuits with a two-phase coolant

    International Nuclear Information System (INIS)

    Blinkov, V.N.

    1993-01-01

    This paper presents a mathematical model and a open-quotes fastclose quotes computer program for analyzing nonstationary thermohydrodynamic processes in distributed multi-element circuits containing a two-phase coolant. The author's approach is based on representing the distributed multi-element circuits with the two-phase coolant (such as cooling circuits of the reactor of an atomic power station) in the form of equivalent thermohydrodynamic chains composed of idealized elements with the intrinsic properties of the structure elements of real systems. The author has developed the nomenclature of such conceptual elements for objects which can be modelled; the nomenclature encompasses the control volumes (with a single-phase or two-phase coolant or a moving boundary of boiling/condensation) and the branch lines (type of tube and connections in dependence on the inertia of the coolant being taken into account) for a hydrodynamic submodel and the thermal components and lines for a thermal submodel. The mathematical models which have been developed and the program using them are designated for various forms of calculating slow thermohydrodynamic processes in multi-element coolant circuits in reactors and modeling test stands. The program facilitates calculation of the range of stable operation, detailed studies of stationary and nonstationary modes of operation, and forecasts of effective engineering measures to obtain stability with the aid of microcomputers

  13. Multi-element analysis of wheat flour and white bread by neutron activation.; Analisis multielemental en harina de trigo y pan blanco por activacion neutronica.

    Energy Technology Data Exchange (ETDEWEB)

    Godinez A, M A

    1994-12-31

    One of the best source of feeding even for the human being as for animals are the Cereals. Although they are mainly energetic aliment, due to its composition in starch, they are a very important source of proteins and amino acids. They contribute mineral elements to the diet. Even those elements constitute a very small part of the total diet, they take a very important place in many human metabolic processes. To make a multielemental analysis of an aliment is very important that we are based on a very sensible analytic technique so we are able to find them, just as the Neutronic Activation. This Nuclear technique allows you to make a qualitative and quantitative analysis of the elements that are in a sample, but it does n`t show the way in which the elements are presented. It is based in turning those elements into radioactive ones through its exposition to an uniform and constant fluid of neutrons, so then its radioactivity can be determined. The present work has as a main purpose to make a multielemental analysis of the wheat flour and white bread through the Neutronic Activation Technique, using the comparator method and establishing previously the most appropriate work conditions as much irradiation as digestion and measuring of the radioactivity of the sample. In this way, it was able to know that the wheat flour has potassium, chlorine, magnesium, sodium, iron, zinc, manganese, rubidium and selenium elements in a concentration of 2000, 700, 500, 25, 18, 13, 5.5, 0.9 and 0.01 - 0.3 mg/g respectively. In an other hand it was found that the white bread has the same elements than the wheat flour but its concentration was: 1700, 9000, 400, 7000, 52, 13, 6, 1 and 0.05 - 0.3 mg/g respectively. (Author).

  14. Systematic Integrated Process Design and Control of Reactive Distillation Processes Involving Multi-elements

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil; Sales-Cruz, Mauricio; Huusom, Jakob Kjøbsted

    2016-01-01

    driving force approach. Next, through analytical, steady-state and closed-loop dynamic analysis it is verified that the control structure, disturbance rejection and energy requirement of the reactive distillation column is better than any other operation point that is not at the maximum driving force...

  15. Geological prospecting in La Primera area (Caballo Torcido) Fotoplano M-25 Mal Abrigo San Jose town

    International Nuclear Information System (INIS)

    Coronel, N.; Techera, J.; Pias, J.; Ramos, E.; De Souza, S.

    1990-01-01

    This work describes the prospection results in La Primera (Caballo Torcido) area in San Jose town. In this zone has been extracted metallic minerals, sediments and multielement soil samples to detect geochemical anomalies.

  16. Chemical characterization of archaeological ceramics using k{sub 0} based INAA: A study in the production and distribution of middle horizon pottery from Cuzco, Peru

    Energy Technology Data Exchange (ETDEWEB)

    Montoya, E; Glowacki, M; Zapata, J; Mendoza, P [Departamento de Quimica, Instituto Peruano de Energia Nuclear, Lima (Peru)

    2003-08-01

    The objective of this research was to establish, in general terms, the provenance of certain pottery styles that are found in the Peruvian southern highlands, in the Cuzco region. Previous work allowed identification of ceramic influences from outside Cuzco, namely from the Peruvian central highlands, the heartland of the Wari culture, and from the high plateau region of Bolivia and Peru (the Altiplano), the centre of Tiwanaku society. One of the goals was to determine which of these ceramic styles were made in other regions and brought to Cuzco, and which of them were locally manufactured imitations. In addition, an attempt was made to compare their patterns of production and distribution with those of local ceramic styles. These data, in turn, were found helpful in understanding some aspects of the social, economic and political dynamics of the Middle Horizon period at Cuzco. To realize this objective, a set of about 350 ceramic samples was chemically analysed using instrumental neutron activation analysis (INAA) and the results processed by multivariate statistical methods. From the pioneering works of Sayre, INAA has become a major tool in multielement compositional characterization of archaeological ceramics. One of the best ways to carry out INAA is the k{sub 0} standardization method, first developed by De Corte et al. [De Corte, F., Habil. Thesis, University of Gent (1987), De Corte, F., et al., J. Radioanal. Chem. 62 (1981) 209 pp.]. It was very effective in accurate multielement analysis of large numbers of samples and has been employed in the Instituto Peruano de Energia Nuclear (IPEN) laboratory since 1993. Special care was taken in our research to maintain quality control of the analytical results, which were produced in duplicate for every sample, and for repeated analysis of NIST SRM-2704 (Buffalo River Sediment) and other reference materials such as the well known Old Ohio Red Clay. (author)

  17. Alternative approaches to correct interferences in the determination of boron in shrimps by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pasias, I.N.; Pappa, Ch.; Katsarou, V.; Thomaidis, N.S., E-mail: ntho@chem.uoa.gr; Piperaki, E.A.

    2014-02-01

    The aim of this study is to propose alternative techniques and methods in combination with the classical chemical modification to correct the major matrix interferences in the determination of boron in shrimps. The performance of an internal standard (Ge) for the determination of boron by the simultaneous multi-element atomic absorption spectrometry was tested. The use of internal standardization increased the recovery from 85.9% to 101% and allowed a simple correction of errors during sampling preparation and heating process. Furthermore, a new preparation procedure based on the use of citric acid during digestion and dilution steps improved the sensitivity of the method and decreased the limit of detection. Finally, a comparative study between the simultaneous multi-element atomic absorption spectrometry with a longitudinal Zeeman-effect background correction system, equipped with a transversely-heated graphite atomizer and the single element atomic absorption spectrometry with a D{sub 2} background correction system, equipped with an end-heated graphite atomizer was undertaken to investigate the different behavior of boron in both techniques. Different chemical modifiers for the determination of boron were tested with both techniques. Ni-citric acid and Ca were the optimal chemical modifiers when simultaneous multi-element atomic absorption spectrometry and single-element atomic absorption spectrometry were used, respectively. By using the single-element atomic absorption spectrometry, the calculated characteristic mass was 220 pg and the calculated limit of detection was 370 μg/kg. On the contrary, with simultaneous multi-element atomic absorption spectrometry, the characteristic mass was 2200 pg and the limit of detection was 5.5 mg/kg. - Highlights: • New approaches were developed to cope with interferences of B determination by ETAAS • Ge was used as internal standard for the determination of B by simultaneous ETAAS • Citric acid was used during

  18. Study on the influence of X-ray tube spectral distribution on the analysis of bulk samples and thin films: Fundamental parameters method and theoretical coefficient algorithms

    International Nuclear Information System (INIS)

    Sitko, Rafal

    2008-01-01

    Knowledge of X-ray tube spectral distribution is necessary in theoretical methods of matrix correction, i.e. in both fundamental parameter (FP) methods and theoretical influence coefficient algorithms. Thus, the influence of X-ray tube distribution on the accuracy of the analysis of thin films and bulk samples is presented. The calculations are performed using experimental X-ray tube spectra taken from the literature and theoretical X-ray tube spectra evaluated by three different algorithms proposed by Pella et al. (X-Ray Spectrom. 14 (1985) 125-135), Ebel (X-Ray Spectrom. 28 (1999) 255-266), and Finkelshtein and Pavlova (X-Ray Spectrom. 28 (1999) 27-32). In this study, Fe-Cr-Ni system is selected as an example and the calculations are performed for X-ray tubes commonly applied in X-ray fluorescence analysis (XRF), i.e., Cr, Mo, Rh and W. The influence of X-ray tube spectra on FP analysis is evaluated when quantification is performed using various types of calibration samples. FP analysis of bulk samples is performed using pure-element bulk standards and multielement bulk standards similar to the analyzed material, whereas for FP analysis of thin films, the bulk and thin pure-element standards are used. For the evaluation of the influence of X-ray tube spectra on XRF analysis performed by theoretical influence coefficient methods, two algorithms for bulk samples are selected, i.e. Claisse-Quintin (Can. Spectrosc. 12 (1967) 129-134) and COLA algorithms (G.R. Lachance, Paper Presented at the International Conference on Industrial Inorganic Elemental Analysis, Metz, France, June 3, 1981) and two algorithms (constant and linear coefficients) for thin films recently proposed by Sitko (X-Ray Spectrom. 37 (2008) 265-272)

  19. Classical microdosimetry in radiation protection dosimetry and monitoring

    International Nuclear Information System (INIS)

    Waker, A.J.; Schrewe, U.; Burmeister, J.; Dubeau, J.; Surette, R.A.

    2002-01-01

    Classical microdosimetry concerns the measurement and analysis of the spectrum of radiation energy deposition events in simulated microscopic tissue-equivalent sites. Over the past three decades, classical microdosimetry has been extensively applied for the direct measurement of dosimetric quantities, such as the ambient dose equivalent, and for the spectroscopic properties of tissue-equivalent proportional counters that have led to the methods of mixed-field analysis and particle identification. This paper reviews some of the special applications of classical microdosimetry such as the determination of kerma coefficients, differential dosimetry and aviation dosimetry. Also reviewed are some of the technological innovations related to the application of microdosimetry in operational health physics and in particular the development of multi-element proportional counters and detectors based on gas microstrip technology. (author)

  20. Analytical chemical system for the determination of heavy metals and organic compounds. Annual progress report, December 1, 1978-November 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Siggia, S.; Barnes, R.M.

    1979-10-24

    Progress has been made in the synthesis and characterization of new resins for sequestering inorganic and organic compounds. The capabilities of the poly(dithiocarbamate) resin have been extended, a new poly(acrylamidoxime) resin prepared and characterized, and a series of resins for organic compounds prepared and tested. Limited actual sample analyses have been performed with these resins. A new inductively coupled plasma source, spectrometer, and computer system have been received and they are undergoing tests and installation. With this system in place, the multielement analysis of metals during the forthcoming period will insure the application of sequestering resins to practical analysis of energy-related materials. An automated sample handling and data system has been designed, some components purchased, and construction is scheduled for 1980.