  1. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  2. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  3. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  4. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  5. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  6. Value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Wang Kang; Zhao Zehua; Wang Zhi; Wang Weizhong; Xu Songsen; Zhang Miao; Liu Wenjin; Zhang Guozhen; Feng Dianxu

    2005-01-01

    Objective: To investigate the value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis. Methods: A total of 39 patients with clinically suspected acute appendicitis underwent surgery from February, 2002 to September, 2003. They were prospectively examined before surgery with routine CT scanning and MPVR reconstruction spiral CT. 31 cases of appendicitis were confirmed after appendectomy. CT scans and surgery-pathology reports were evaluated on a five-grade scale from hyperemic-edematous appendix to abscess (normal appendix: 0 grade). Results: The results of spiral CT MPVR reconstruction were compared with the surgical and pathologic findings at appendectomy, yielding an accuracy of 87.2%, sensitivity of 90.3%, specificity of 75%, positive predictive value of 93.3%, and negative predictive value of 66.7%, respectively. Results of routine CT yielded an accuracy of 38.5%, sensitivity of 38.7%, specificity of 37.5%, positive predictive value of 70.6%, and negative predictive value of 13.6%, respectively. MPVR reconstruction signs of 28 patients with acute appendicitis included enlarged appendix ( > 6 mm) (96.4%), appendicoliths (26.7%), caecal apical thickening (36.7%), periappendiceal inflammation (71.4%), and abscess (10.7%). Conclusion: The use of spiral CT MPVR reconstruction in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to a significant improvement in the preoperative diagnosis and maybe a decrease in surgical-pathologic severity of appendiceal disease. (authors)

  7. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  8. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  9. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  10. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  11. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  12. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  13. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  14. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  15. Evaluation of the nutcracker syndrome using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Fan Yanqing; Han Ping; Zhou Chengkai; Zhao Long; Wu Hongying; Yu Qun; Liu Yonghua

    2007-01-01

    Objective: To evaluate the ability of multi-slice spiral CT (MSCT) in diagnosing nutcracker syndrome(NCS). Methods: MSCT angiography (MSCTA) or contrast enhanced CT data of 16 patients clinically diagnosed as NCS( patient group) and 80 subjects with nomal kidneys and renal vessels (control group ) were retrospectively reviewed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The angle (a) between SMA and the abdominal aorta (AA), the distance (d) between SMA and AA at the level of LRV passing through, the cross areas of LRV through the angle (s1) and at the largest diameter near the renal hilar (s2) were measured and the ratio(q) of s2 to sl was calculated. Results: All LRVs were compressed and showed dilated, 7 of them with the genesial gland vein enlargement. The causes of the LRV narrowing and obstruction were small angle (a) in 14 patients and abnormal path of LRV posterior to AA in 2 cases. The value of a,d,s1,s2 and q in the patient group and the control group were: (21±4) degree, (0.53±0.11) cm, (0.28±0.06) cm 2 , (1.42±0.48) cm 2 , 5.26 and (52±24) degree, (1.39±0.70) cm, (0.81±0.32) cm 2 , (1.21±0.35) cm 2 , 1.52, respectively. The differences were significant between the two groups (P< 0.05). Conclusion: The appearance and its path of the LRV could be well delineated on the MSCT, allowing a accurate evaluation of the LRV narrowing non-invasively. (authors)

  16. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  17. The value of multi-slice spiral CT in the preoperative assessment of living renal donor

    International Nuclear Information System (INIS)

    Li Qinghai; Yan Fuhua; Xu Pengju; Zhou Meiling; Zhu Tongyu; Xu Ming; Wang Guomin

    2008-01-01

    Objective: The purpose of this study is to assess the value of multi-slice spiral CT (MSCT) in the preoperative evaluation of living renal donor as a all in one modality. Methods: Thirty-six potential living renal donors underwent the examination using a GE light VCT scanner. Informed consent was obtained from all participants. The plain scan, early arterial phase, late arterial phase and excretory phase scans are performed in the former 25 donors (injection rate 5 rolls, total volume 100 mi, tube tension 120 kV). While in the later 11 donors (2 ml/s 40 ml +4 ml/s 60 ml), the scanning protocol included the plain scan ( 100 kV), vascular phase and excretory phase scans (100 kV). The excretory phase data were used in the reconstruction of CT urography in both groups. All images were reviewed by one radiologist and one urologist, and the findings of MSCT were compared with intraoperative findings for 33 donors, to investigate the utilities of MSCT in assessing renal vascularity, urinary tract and lesions of renal parenchyma. When discrepancies are found between the two reviewers, consensus was obtained via discussion. Au data was statiscally processed with SPSS for Windows. Results: MSCT angiography is in accordance with intraoperative findings in demonstrating the anatomy of renal arteries and renal vein trunk, accesary arteries, early branching of renal artery. The findings from CTA are highly in accordance with the intraoperative findings, which facilitate intraoperative ligation and reduce relevant complications. CTU demonstrates the anatomy of urinary, tract in good agreement with the intraoperative findings. The image quality of 3D vascularity and CTU between the two groups, scored 4.4 ± 1.2 vs 4.2 ± 1.3 and 4.6 ± 0.8 vs 4.4 ± 0.9 respectively, no statistical between-groups difference was found (Z=-0.89, -0.47, P>0.05). Conclusion: MSCT multiphase scanning combined with CTA and CTU play a important role in the evaluation of living renal donor, which

  18. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  19. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  20. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  1. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  2. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  3. Value of multi-slice spiral CT in diagnosis the detection of fish bone impaction in the esophagus

    International Nuclear Information System (INIS)

    Luo Min; Hu Daoyu; Wang Qiuxia; Pei Yigang

    2009-01-01

    Objective: To investigate the detection rate and diagnostic value of multi-slice spiral CT scan in detecting fish bone impaction in the esophagus. Methods: Experimental group: 30 fresh water fish bones from three variety classes were divided into three groups with length of (23.36±0.15), (28.51± 0.07) and (30.89±0.10) mm, and diameter of (4.49±0.31), (1.78±0.09) and (0.49±0.07) mm. The fish bones were put into esophagus models in three different types including parallel, perpendicular and oblique. MSCT with axial scan combined with three dimensional reconstruction technique and plain X-ray film ( CR and DR) were used to examine the model. The relations of the number and rate of fish bones were compared between MSCT and X-ray film. Clinical group: MSCT imaging were performed in 20 cases proved by esophageal endoscope or clinical operation, among which 11 cases received plain X-ray film (CR and DR), 15 cases received Barium-soaked cotton and 17 cases received endoscope. Paired Chi-square test was used to compare the differences of detection of fishbone by the different ways. Results: In experimental group: All the 90 cases (100%) fish bones of three different species were clearly revealed on MSCT image; only 60 cases (66.7%) fish bones were revealed by plain X-ray film (CR and DR). The number and rate of fish bones detected by MSCT was higher than that of plain X-ray film (CR and DR) (χ 2 =28.03, P 2 =7.11, P 2 =4.17, P<0.05). Conclusions: The sensitivity and detection rate of fish bone with MSCT was high and could evaluate the surrounding and complications of the esophagus. MSCT could be used as the first examination of impacted fish bones in the esophagus. (authors)

  4. Blood flow patterns of solitary pulmonary nodules with enhancement: clinical value of multi-slice spiral CT

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Liu Huimin; Li Yuli; Li Huimin; Li Chengzhou; Zhang Chenshi; Tao Zhiwei; Yang Chunshan; Jiang Qingjun; Ouyang Lin; Yu Hong

    2004-01-01

    Objective: To evaluate the efficacy of dynamic multi-slice spiral computed tomography (MSCT) for providing quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs) and the correlation of vascular endothelial growth factor (VEGF)-positive tumor angiogenesis and the quantifiable parameters of blood flow pattern in solitary bronchogenic adenocarcinoma. Methods Seventy-eight patients with SPNs (with strong enhancement) (diameter ≤4 cm; 68 malignant; 10 active inflammatory) underwent multi-location dynamic contrast enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4 ml/s by using an autoinjector) serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion, peak height, and ratio of peak height of the SPN to that of the aorta were calculated. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. The quantifiable parameters (perfusion, peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta and mean transit time) of blood flow pattern in 30 VEGF-positive solitary bronchogenic adenocarcinoma were compared with microvessel densities (MVD) and VEGF expression by immunohistochemistry. Results: No statistically significant difference in the peak height was found between malignant (35.79 ± 10.76) HU and active inflammatory (39.76 ± 4.59) HU nodules (t=1.148, P=0.255). SPN-to-aorta ratio (14.27 ± 4.37)% and perfusion value (3.02 ± 0.96)ml -1 ·min -1 ·kg -1 in malignant SPNs were significantly lower than those of active inflammatory nodules(18.51 ± 2.71)%, (6.34 ± 4.39)ml -1 ·min -1 ·kg -1 (t=2.978, P=0.004, t=5.590, P -1 ·min -1 ·kg -1 , mean transit time (14.86 ± 5.84) s, and MVD (70.15 ± 20.03). Each of peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta, and perfusion correlated positively with MVD (r=0.781, P<0.0001; r=0

  5. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  6. The investigation of the lateral atlanto-dental interval of atlanto-axial joint by multi-slice spiral CT

    International Nuclear Information System (INIS)

    Cui Wei; Peng Lei; Wang Jincai; Liu Jihua; Feng Weihua

    2010-01-01

    Objective: To explore imaging features of the lateral atlanto-dental interval (LADI) of atlanto-axial joint and its value in the diagnosis of atlanto-axial joint dislocation/subluxation. Methods: Two hundred and forty healthy volunteers without atlanto-axial joint dysfunction and 32 patients with torticollis and/or functional impairment at atlanto-axial.joint were enrolled into this study. All subjects were examined with multi-slice CT in both neutral and max rotation positions to the left/right. Clinical endpoints including VBLADI, variance range of the VBLADI and asymmetric conditions were evaluate. χ 2 test is used to evaluate the variance of incidence of bilateral LADI asymmetry in different age groups, Pearson-test (2-tailed) is used to evaluate the correlation between VBLADI and rotary function of atlanto-axial joint, precise test of fourfold table is used to compare normal group with patient groups. Results: (1) In the normal control group: asymmetry of bilateral LADI were observed in 204 among 240 (85.00%) healthy volunteers including 60 youngsters ( 95% of ∣ VBLADI ∣ were 0.850 mm, 2.450 mm in the young ( 95% in the young and in the adult respectively. There was no correlation between VBLADI(-2.146 to 2.114 mm, Median 0.000 mm) and LA (22.949° to 44.649°, Median 34.500°), RA (25.284° to 45.334°, Median 35.300°), VLRA (-11.643° to 8.623°, median 0.000°) respectively in normal people (r=-0.030, -0.005, 0.026, P>0.05). (2) In the study with 32 patients including 25 youngsters ( 95% in group AALSD and group AACD than in abnormal group (P<0.01), but there is no difference between group AARD and normal group (P=0.738). Conclusion: The imaging finding of 'asymmetry of bilateral LADI' may be either a physiological variation or a pathological condition, clinical manifestations and other imaging findings should be evaluated to make a diagnosis. (authors)

  7. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  8. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Watzke, Oliver; Kalender, Willi A.

    2001-01-01

    In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region

  9. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  10. Multi-slice spiral CT of the coronary arteries: improved vessel presentation by means of a standard software

    International Nuclear Information System (INIS)

    Schmitt, R.; Froehner, S.; Coblenz, G.; Christopoulos, G.; Brunn, J.; Mueller, M.; Kerber, S.; Fellner, F.

    2001-01-01

    Material and methods: Image data of 151 patients suffering from coronary artery disease were calculated by means of retrospective triggering at four different diastolic delay times in contrast-enhanced CT. The large coronary segments were subsequently reconstructed in two planes with multiplanar volume reconstruction (MPVR). Results: On the pre-condition that data sets were acquired at sinus rhythm and at a heart beat rate lower than 65/min coronary arteries could be depicted over a long distance in single or double angulated reconstruction planes with the help of MPVR. Time consumption for image reconstruction was reasonable. Additionally to the anatomy of the coronary arteries in two different planes, typical CT findings in occluding coronary artery disease are presented. (orig.) [de

  11. Multi-slice spiral CT multiplanar reconstruction findings of localized fat collection adjection to the subdiaphragmatic inferior vena cava

    International Nuclear Information System (INIS)

    Cao Hetao; Lu Jian; Zhao Jinli; Liu Tingting; Qin Jufeng; Xu Wen; Qin Jiangchun; Jiang Junkang

    2012-01-01

    Objective: To discusses the MSCT multiplanar reconstruction manifestation (MPR) of localized fat collection adjection to subdiaphragmatic inferior vena cava (IVC fat ). Methods: The thoracic and abdominal MSCT scan data of 8246 patients were browsed,45 patients with presumed IVC fat on axial CT scans were further studied prospectively with MSCT MPR. The predisposing position of IVC fat and its relationship with IVC were observed. It was divided into two kinds of intraluminal type and extraluminal type according to the angle of IVC fat with respect of the wall of IVC.The other 50 patients without IVC fat were randomly selected as the control group. The sagittal inclination angle (SIA) and diameter ratio (DR) between supra- and sub-diaphragmatic IVC between the two groups were compared by using t test. Results: The detection rate was 0.55% (45/8246). Of which hepatic vein lacuna 8 patients, subdiaphragmatic gap medial to IVC 28 patients and IVC groove 9 patients. The shape of IVC fat showed mainly for the round, oval and crescents on axial CT scans, of 15 patients intraluminal type, 4 showed 'target signs'. The shape of IVC fat showed mainly for 'half-moon' at MPR.The SIA and DR at IVC fat group were 21.62° ± 8.42° and 2.01 ±0.84 respectively, at control group were 16.75° ±7.82° (t=1.594, P>0.05) and 1.31 ±0.28 (t=2.341, P<0.05) respectively. Conclusion: The round, oval or half of limited fat density shadow adjection to subdiaphragmatic inferior vena cava which similar to in the lumen is the characteristic performance of IVC fat , it may be an anatomical variation. (authors)

  12. The value of multi-slice spiral CT liver perfusion imaging to evaluate the chronic hepatic fibrosis and cirrhosis

    International Nuclear Information System (INIS)

    Long Liling; Huang Zhongkui; Ding Ke; Liao Jinyuan; Jiang Jianning

    2012-01-01

    Objective: To investigate the value of the MSCT liver perfusion imaging parameters in the evaluation of the chronic hepatic fibrosis and cirrhosis. Methods: Liver CT perfusion (CTP) was performed in 107 participants,including 31 patients with mild hepatic fibrosis (S1, S2), 34 patients with severe hepatic fibrosis (S3, S4) and early stage of hepatic cirrhosis which conformed by liver pathologic biopsy, 42 patients with hepatic cirrhosis who had typical clinical and image signs, and 30 healthy subjects as control group. The data of CTP (HAP, PVP, LTP, HPI and TTP) at different stages were obtained with Body perfect CT-syngo CT2007A and control study with histopathologic stage. Compared the study index by the one-way ANOVA analysis. Used Spearman rank correlation to analysis the relationship between liver perfusion imaging parameters and the degrees of the chronic hepatic fibrosis. Used Logistic regression to analysis the maximum regression coefficient among the liver perfusion imaging parameters, which affected the histopathologic stage mostly. Results: In the subgroups of the chronic hepatic fibrosis S1, S2, S3, S4 to the hepatic cirrhosis,HAP values was (28.9 ±8.6), (24.6 ±2.4), (29.2 ±2.3) and (38.9 ± 7.0) ml · 100 ml -1 · min -1 , respectively. HAP decreased firstly,then increased. Statistic analysis showed the difference of HAP between later-stage cirrhosis and other groups (F=40.26, P<0.01). PVP values of above subgroups was (111.3 ± 18.1), (92.9 ±5.3), (73.0 ±9.0) and (54.1 ± 13.8) ml · 100 ml -1 ·min -1 , respectively. TLP values of above subgroups was (140.2 ± 25.9), (117.1 ± 4.5), (102.3 ± 8.7)and (93.0 ± 11.8) ml · 100 ml -1 ·min -1 , respectively. The difference of PVP, TLP among each subgroup was significant (F=136.79, 67.40, respectively, P<0.01). HPI values of above subgroups was (20.4 ± 2.6)%, (21.0 ±2.1)%, (28.5 ±3.1)% and (42.6± 11.1)%, respectively. TTP values of above subgroups was (123.7±22.2), (137.1 ±27.1), (145.0 ±28

  13. Value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression

    Directory of Open Access Journals (Sweden)

    Ai-Jun Wu

    2016-12-01

    Full Text Available Objective: To study the value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression. Methods: A total of 135 patients with gastric cancer who received surgical resection in our hospital between May 2012 and October 2015 were selected as the research subjects, preoperative enhanced multi-slice spiral CT scan was conducted to judge TNM staging, and serum was collected to determine the content of tumor markers; tumor tissue was collected after operation to determine the content of cytokines and pro-proliferation molecules. Results: CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM II, III and IV stage gastric cancer were significantly higher than those of patients with TNM I stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM III and IV stage gastric cancer were significantly higher than those of patients with TNM II stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM IV stage gastric cancer were significantly higher than those of patients with TNM III stage. Conclusions: TNM staging of gastric cancer decided by preoperative enhanced multi-slice spiral CT scan has good consistency with the content of tumor markers in serum and proliferation molecules in tumor lesion.

  14. PET/CT和MSCT联合应用在孤立性肺结节诊断中的价值%PET-CT with multi-slice spiral CT in the diagnosis of SPN

    Institute of Scientific and Technical Information of China (English)

    汪世存; 方雷; 潘博; 展凤麟; 谢强; 谢吉奎

    2009-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射显像/电子计算机断层扫描成像(18F-deoxyglucose positron emission tomography /computer tomography 18F-FDG PET/CT)和多排CT( multi-slice spiral CT,MSCT)联合应用在孤立性肺结节(SPN)诊断中的价值.方法 87例SPN患者均行PET/CT及肺部病灶MSCT检查,影像诊断结果 与病理对照,进行统计分析.结果 87例SPN中,MSCT诊断正确64例,误诊23例,误诊率26.4%.PET/CT诊断正确70例,误诊17例,误诊率19.5%.MSCT和PET/CT联合诊断,80例诊断正确,7例误诊,误诊率8.0%.MSCT、PET/CT及两者联合诊断的敏感性、特异性和准确性分别为87.2%、68.1%、79.8%;89.5%、61.3%、81.4%和97.7%、74.2%、91.5%.MSCT和PET/CT单独诊断SPN的准确性无统计学意义(χ2=0.625,P=0.239),MSCT、PET/CT与两者联合应用诊断SPN的准确性均有统计学意义(χ2=7.762和5.318,P=0.005和0.021).结论 SPN的MSCT和PET/CT影像特征均有一定的重叠.单独采用MSCT或PET/CT诊断肺结节无明显统计学差异,MSCT和PET-CT协同诊断的准确性高于MSCT或PET/CT单独诊断.%Aim To evaluate the value of a combination of 18F-FDG PET-CT with multi-slice spiral CT in the diagnosis of SPN.Methods 18F-FDG PET-CT and multi-slice spiral CT were performed in 87 patients with SPN.The pathologically-proved findings were compared with findings diagnosed by MSCT and retrospectively analyzed.Results In 87 cases,the numbers of correct diagnosis and misdiagnosis with MSCT were 64 and 23 respectively,the misdiagnosis rate 26.4%,while the numbers of correct diagnosis and misdiagnosis with PET/CT were 70 and 17,the misdiagnosis rate 19.5%,but 50 cases were correctly diagnosed and 7 cases were misdiagnosed by combining 18F-FDG PET-CT with MSCT,the misdiagnosis rate 8.0%.The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of MSCT,PET/CT,and MSCT combined with PET /CT were 87.2%,68.1%,79.8%;89.5%,61.3%,81.4% and 97

  15. Analysis on the value of the multi-slice spiral CT and MRI scanning for applying to the identifying diagnosis of the new and old vertebral compresion fracture

    International Nuclear Information System (INIS)

    Huo Zhiyi; Gao Shuming; Li Dasheng; Pei Lijun; Qu Hui

    2008-01-01

    Objective: To analyze and explore the value of the mutislice spiral CT (MSCT) scanning, its reconstructive technology and MRI scanning for applying to the identifying diagnosis of new and old vertebral compresion fracture. Methods: One hundred and sixty-seven cases with the new and old vertebral compresion fracture who have 189 vertebrae in total were examined using the MSCT scanning, their imaging information were postprocessed with 2D and 3D reconstruction at the work station. Thirty-four patients with overall 43 vertebrae were carried out by MRI scanning and their images were compared with those of MSCT. Results: They had the highest proportion of vertebrae in L1 with accounting for 27.68% (31/112) and 35.06% (27/77) among the patients with new and old vertebral compresion fracture, respectively. The next was T12, L2 and T11. There were statistically significant differences between new and old cases in such appearance as fracture line clear and sharp (102 and 21), contusion and hemorrhage of spinal cord (15 and 0), parenchyma shadow beside vertebrae(103 and 11), appendant fracture(26 and 5), organ's lacerated wound around vertebral body (30 and 0), discus intervertebrales vacuum (10 and 36), derangement and hardening of vertebral bone trabecularism (29 and 51) (P 1 WI signal, 27 vertebrae with the T 2 WI fat-suppresion irregular high signal were demonstrated in MRI scanning among 27 vertebrae of 21 cases with new vertebral compresion fracture. While 16 vertebrae with the T 1 WI and T 2 WI signals were the same as those of the normal vertebrae, 16 vertebrae were the T 2 WI fat-suppresion low signal among 13 cases with old vertebral compresion fracture. Conclusions: The MSCT plays an important role in identifying diagnosis for the most of the patients with the new and old vertebral compresion fracture, while MRI scanning may reflect the pathophysiological characteristics in diagnosis of the spinal cord and the ligament lesion. Therefore, the MSCT and MRI scanning

  16. MSCT在主动脉壁内血肿诊断和转归中的应用%Application of multi-slice spiral CT in diagnosis and prognosis of aortic artery intramural hematoma

    Institute of Scientific and Technical Information of China (English)

    黄源义; 谢欢; 邬正宏; 刘四斌

    2011-01-01

    Objective To investigate the applied value of multi-slice spiral CT in diagnosis and prognoses of aortic artery intramural hematoma(IMH). Methods 11 patients with IMH underwent plain CT scan and CT angiography with 16-slice spiral CT of GE. Endovascular stent for the treatment in 3 cases and conservative treatment in 8 cases was performed. All patients were followed-up twice or 4 times for 15 - 210 days(mean 112. 5 days). Results 3 cases with Stanford A and 8 cases with Stanford B IMH were diagnosed. The main CT findings were as follows: Crescent or circular thickening(>5 mm)of aortic wall with higher density or isodensi-ty without intimal flap as well as true and false lumen in 11 cases;atherosclerosis in 7 cases;intimal calcification ingression in 4 cases; intimal leakages in 3 cases;penetrating ulcer in 3 cases. The hematomas in 7 cases were completely absorbed,incomplete absorbed in 2 cases,while 2 cases were transformed to dissecting aneurysm. Conclusion MSCT is a significant method in diagnosis and follow-ing-up of IMH, and can provide important informations for clinical treatment.%目的 探讨MSCT在主动脉壁内血肿(IMH)诊断和转归中的应用价值.方法 采用GE 16排螺旋CT对11例IMH行平扫和CTA扫描.3例行腔内支架隔绝术,8例保守治疗.所有病例治疗后随访2~4次,随访时间15~210 d(平均112.5 d).结果 A型IMH 3例,B 型IMH 8例.MSCT主要征象为:11例主动脉壁新月形或环形增厚>5 mm,呈等密度或高密度,无内膜片撕裂及真、假两腔形成;主动脉粥样硬化7例;内膜钙化内移4例;内膜渗漏3例;穿透性溃疡3例.7例完全吸收,2例部分吸收,2例进展成夹层动脉瘤.结论 MSCT能对IMH作出明确的诊断,并可作为IMH随访的重要检查手段,对临床治疗有重要的指导意义.

  17. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  18. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  19. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  20. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  1. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  2. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  3. The diagnostic value of multi-slice CT on the congenital malformation of coronary sinus

    International Nuclear Information System (INIS)

    Li Wei; Ma Xiaojing; Sun Qingjun

    2012-01-01

    Objective: To investigate the application value of multi-slice spiral CT on the congenital malformation of coronary sinus. Methods: MSCT finding of 98 patients with coronary sinus malformation confirmed by surgery were retrospectively analyzed,and the cases were divided into four categories based on the Mantini theory and comparison was made between the diagnosis from ultrasound and CT. A 2 × 2 table for Chi-square test was also used for statistics analysis. Results: Among 98 patients,there were 72 patients with persistent left superior vena cava reflowed to right atria through coronary sinus, with 48 patients diagnosed by ultrasound and 72 patients by MSCT; there were 13 patients with anomalous pulmonary venous connection to coronary sinus, with 12 patients diagnosed by ultrasound and 13 patients by MSCT diagnosis; there were 10 patients with unroofed coronary sinus syndrome, with 6 patients diagnosed by ultrasound and 8 patients by MSCT, there were 2 patients with coronary sinus atresia, all diagnosed by MSCT; there were 1 patient with coronary sinus anomaly reflow to left arita. The significant difference between 2 modalities (χ 2 =22.7, P<0.01) shows that CT is superior to ultrasound. Conclusion: MSCT is much more better than ultrasound in the diagnosis of malformation of coronary sinus and it can provide reliable diagnosis prior to surgery or interventional therapy. (authors)

  4. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  5. Dynamic bowtie filter for cone-beam/multi-slice CT.

    Directory of Open Access Journals (Sweden)

    Fenglin Liu

    Full Text Available A pre-patient attenuator ("bowtie filter" or "bowtie" is used to modulate an incoming x-ray beam as a function of the angle of the x-ray with respect to a patient to balance the photon flux on a detector array. While the current dynamic bowtie design is focused on fan-beam geometry, in this study we propose a methodology for dynamic bowtie design in multi-slice/cone-beam geometry. The proposed 3D dynamic bowtie is an extension of the 2D prior art. The 3D bowtie consists of a highly attenuating bowtie (HB filled in with heavy liquid and a weakly attenuating bowtie (WB immersed in the liquid of the HB. The HB targets a balanced flux distribution on a detector array when no object is in the field of view (FOV. The WB compensates for an object in the FOV, and hence is a scaled-down version of the object. The WB is rotated and translated in synchrony with the source rotation and patient translation so that the overall flux balance is maintained on the detector array. First, the mathematical models of different scanning modes are established for an elliptical water phantom. Then, a numerical simulation study is performed to compare the performance of the scanning modes in the cases of the water phantom and a patient cross-section without any bowtie and with a dynamic bowtie. The dynamic bowtie can equalize the numbers of detected photons in the case of the water phantom. In practical cases, the dynamic bowtie can effectively reduce the dynamic range of detected signals inside the FOV. Furthermore, the WB can be individualized using a 3D printing technique as the gold standard. We have extended the dynamic bowtie concept from 2D to 3D by using highly attenuating liquid and moving a scale-reduced negative copy of an object being scanned. Our methodology can be applied to reduce radiation dose and facilitate photon-counting detection.

  6. Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT

    International Nuclear Information System (INIS)

    Gao Jianhua; Li Tao; Mi Fengtang; Li Na; Cui Ying; Dai Ruping; Li Jianying

    2009-01-01

    Objective: To characterize the association between the mean CT value on a scout view and the dependent mA selection method, and to evaluate the clinical value of a mA selection method based on scout view mean CT value in obtaining individualized scan protocol and consistent image quality for patient population on 64-row MSCT CT coronary angiography (CTCA). Methods: One hundred patients (group A) underwent CTCA consecutively using standard protocol with a fixed mA. The mean CT value of a fixed ROI (region of interest) from the scout AP view and the CTCA image noise (standard deviation on the root of ascending aorta) were measured. The correlation between CT values and noise was studied to establish a formula and a list to determine the required mA for obtaining a consistent CTCA image noise based on the measured SV CT value. Another 100 patients (group B) were scanned using the same parameters as group A except the mA and the CT value was also measured. The mA was determined by the list established previously. The CTCA image quality (IQ) as well as the image noise (IN) and the effective dose (ED) from the two groups were statistically analyzed using t-test. The CT findings for the 32 patients in the group B were also compared with the selective coronary angiography (SCA) results. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CTCA for detection of significant stenosis were obtained. Results: The formula between the required mA and the CT value was: XmA=FmA x [(K 1 x CTscout + C 1 )/INa] 2 . The CTCA images in B group had statistically higher IN (27.66±2.57, 22.22±4.17, t=11.33, P=0.000), but no statistical difference between IQ scores for the two groups (3.29±0.66, 3.37±0.67, t=0.009, P=0.990), and ED [(8.72±2.51) versus (12.53±0.90) mSv] was 30% lower for the B group (P<0.01). For the 32 patients in the B group who had SCA, the CTCA sensitivity, specificity, positive predictive value, negative

  7. Multi-slice CT features of annular pancreas in neonates

    International Nuclear Information System (INIS)

    He Mingqing; Zhu Youzhi; Hu Kefei; Yin Chuangao; Hu Jun; Wang Song; Li Xu; Lu Zhongbin; Wang Yue; Liu Xiang

    2013-01-01

    Objective: To investigate the MSCT manifestations and their values in the diagnosis of annular pancreas in neonates. Methods: Retrospective analysis of clinical and CT findings in 27 cases with surgery-proved annular pancreas in neonates was made. The unenhanced and contrast-enhanced CT images were obtained in 20 patients. Two experienced radiologists determined the site and degree of obstruction, the relationship between the head of the pancreas and the obstruction point, and the surrounding tissue structure. Results: The direct signs included the fluid-filled or gas-filled bowel in the head of pancreas in 4 cases, the enhancement of surrounding soft tissue as enhanced pancreas in 17 cases, disappearance of the fat gap between the intestinal wall and the annular pancreas in 17 cases. The indirect signs included intestinal obstruction in 20 cases, 'single-bubble sign' in 2 cases, 'double-bubble sign' in 18 cases, the distal bowel without gas in 5 cases, small amount of gas in the distal bowel in 15 cases. In 12 of 18 cases showing 'double-bubble sign', the ratio of duodenal bubble diameter (Dd) to stomach bubble diameter (Ds)was over 1.0. The site of obstruction was located in the descending duodenum in 20 cases. The form of obstructed point presented with 'nipple sign' in 15 cases, with 'the mouse tail' in 5 cases. The expansion bowel was located in the head of pancreas in 1 case. Gas was found in the pancreatic duct in 1 case, and 'swirl sign' was shown in 2 cases. Conclusions: MSCT combined with three-dimensional reconstruction techniques can clearly demonstrate the annular pancreas' s shape, the site and degree of obstruction and other malformations. It can provide important information for clinical treatment. (authors)

  8. Multi-slice CT pulmonary function evaluation in emphysema

    International Nuclear Information System (INIS)

    Ge Xiaojun; Zhang Guozhen; Zhu Yanping; Shan Lin; Mao Dingbiao; Ding Qiyong; Hua Yanqing

    2007-01-01

    Objective: To explore the feasibility of evaluating the lung function by MSCT in emphysema. Methods: The MSCT scan and pulmonary function tests (PFT) were respectively performed in 147 receptors within one week. They were randomly divided into 2 groups: group A (120 receptors), including normal, mild, moderate and severe abnormal pulmonary function based on the PFT, for comparing the correlation between pulmonary quantitative indexes of MSCT pulmonary function and PFT and settingup the primary, grade criteria of abnormal pulmonary, function in emphysema, group B (27 receptors) for evaluating the diagnostic accuracy in group A. The total lung was respectively scanned at the full inspiration and full expiration with MSCT. The pulmonary quantitative indexes of MSCT were measured with Siemens Pulmo pulmonary quantitative software. Results: There was correlation between pulmonary quantitative indexes of MSCT and PFT. The Piex/in -910 showed best correlation with FEV 1 % (r= -0. 905, P -910 (χ 2 0.267, P=0.966, accuracy 81.5%), and the primary criteria for abnormal pulmonary, function of emphysema was normal (0-9.9), mild (10.0-34.9), moderate (35.0-74.9) and severe (≥75.0). Conclusion: It is feasible to evaluate the abnormal lung function of emphysema with pulmonary quantitative indexes of CT. The Piex/in 910 was the most effective one in various indexes. (authors)

  9. Preliminary feasibility assessment on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Zhang Chenshi; Tao Zhiwei

    2003-01-01

    Objective: To evaluate the feasibility on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography (MSCT) . Methods: 27 patients with bronchogenic adenocarcinomas (diameter ≤4 cm) underwent multi-location dynamic contrast material-enhanced (90 ml, 4 ml/s) serial CT. These dynamic images were processed with the 'time lapse' software and the 'functional CT' software. Peak heights of bronchogenic adenocarcinoma and the aorta, perfusion and mean transit time (MTT) were measured. Ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta was calculated. Perfusion and mean transit time images were obtained. Results: Peak height of bronchogenic adenocarcinoma was (36.66 ± 13.53) HU. No statistically significant difference in the peak height was found between our results and the results of Ukihide et al (mean peak height 34.1 HU) (t =0.981, P = 0.335). Bronchogenic adenocarcinoma-to-aorta ratio was (15.72±4.66 )%. The difference in bronchogenic adenocarcinoma -to-aorta ratio between our results and the results of Zhang and Kono (mean malignant SPN-to-aorta ratio 14.6%) did not reach statistical significance (t=1.244, P=0.225). The mean perfusion value (3.278 ml·min - · kg -1 ) was in the range of that (1.36-2.98 ml·min -1 ·kg -1 ) measured with a single photon emission CT (SPECT). Mean transit time was (17.60 ± 4.52) s. Conclusion: It is feasible to investigate bronchogenic adenocarcinoma angiogenesis with dynamic MSCT

  10. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  11. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  12. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  13. Multi-slice spiral CT diagnosis of arterial sequestration

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Objective: The purpose of this study was to present the characteristic features on MSCT angiography of arterial sequestration. Methods: The MSCT images of 5 patients with arterial sequestration were retrospectively reviewed. All patients underwent MSCT contrast-enhanced angiography. 3D rendering was made to evaluate the lung parenchyma, bronchial system, and vascular anatomy. Results: All 5 cases demonstrated the anomalous systemic artery (ASA) as an isolated and tortuous artery arising from the descending thoracic aorta, taking a sigmoid course and running along with airway, entering the basal segments of the left lowed lobe. The inferior pulmonary vein (IPV) was significantly engorged. The typical AS was diagnosed in 4 patients. Its ASA intercrossed with the IPV and two branches entering segments 7 and 8 over the IPV, and two branches entering segments 9 and 10 under the IPV. The volume of involved lung shrunk with the artery markedly engorged. A characteristic avascular section was found between the pulmonary artery supplying area and the ASA supplying area, and the bronchi did not accompany the arteries. One was diagnosed atypical AS because of coexistence with bronchial atresia. Conclusion: The arterial sequestration had characteristic MSCT findings. The typical type can be definitely diagnosed, but the atypical type needs further three-dimensional analysis. (authors)

  14. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  15. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  16. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  17. The role of multi-slice CT in preoperative staging of colonic tumors

    International Nuclear Information System (INIS)

    Zhang Miao; Chen Kemin; Zhao Zehua; Ling Huawei

    2005-01-01

    Objective: To determine the accuracy of multi-slice CT pneumocolon in the staging of colonic carcinomas. Methods: Thirty-six patients, who were strongly suspected to have colonic disorders, underwent CT pneumocolon before and after intravenous injection of iodinated contrast agent. CTVE, MPR, SSD, and Raysum images were then obtained by using 4 different softwares in workstation (ADW3.1). 33 positive cases were staged preoperatively according to TNM standard. All cases were proved by surgical or colonoscopic histology. Sensitivity and accuracy of MSCT were determined for the detection of cancers, lymph nodes, and metastases. Results: MSCT pneumocolon examinations demonstrated 32 lesions, missing one case. Sensitivity and positive accuracy value for T staging were 96.97% (32/33) and 87.88% (29/33), respectively; Sensitivity and positive accuracy value for lymph node involvement were 73.91% (17/23) and 69.57% (16/23), respectively. The density of metastatic lymph node was higher than that of normal one. Five cases in M stage were all diagnosed correctly. Conclusion: MSCT pneumocolon is a better method of depicting the colorectal carcinoma. It allows for accurate staging of the colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. However the value for early T staging in colorectal carcinoma and minute metastasis of lymph nodes is limited. It is helpful to combine all the findings of lymph nodes, including the size, density, and location, to make a correct diagnosis. (authors)

  18. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  19. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  20. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    Energy Technology Data Exchange (ETDEWEB)

    Teksam, Mehmet E-mail: mehmetteksam@yahoo.com; McKinney, Alexander; Truwit, Charles L

    2004-12-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass.

  1. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    International Nuclear Information System (INIS)

    Teksam, Mehmet; McKinney, Alexander; Truwit, Charles L.

    2004-01-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass

  2. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  3. Value of multi-slice CT in the classification diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Yi; Zeng Mengsu; Ling Zhiqing; Rao Shengxiang; Liu Yalan

    2008-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) classification in the assessment of the hilar cholangiocarcinoma resectability. Methods: Thirty patients with surgically and histopathologically proved hilar cholangiocarcinomas who underwent preoperative MSCT and were diagnosed correctly were included in present study. Transverse images and reconstructed MPR images were reviewed for Bismuth-Corlette classification and morphological classification of hilar cholangiocarcinoma. Then MSCT classification was compared with findings of surgery and histopathology. Curative resectabilty of different types according to Bismuth-Corlette classification and morphological classification were analyzed with chi-square test. Results: In 30 cases, the numbers of Type I, II, IIIa, IIIb and IV according to Bismuth-Corlette classification were 1, 3, 4, 5 and 17. Seventeen patients underwent curative resections, among which 1, 2, 1, 4 and 9 belonged to Type I, II, IIIa, IIIb and IV respectively. However, there was no significant difference in curative resectability among different types of Bismuth-Corlette classification (χ 2 = 0.9875, P>0.05). In present study, the accuracy of MSCT in Bismuth-Corlette classification reached 86.7% (26/30). The numbers of periductal infiltrating, mass forming and intraductal growing type were 13, 13 and 4, while 6, 8 and 3 cases of each type underwent curative resections. There was no significant difference in curative resectability among different types of morphological classification (χ 2 =1.2583, P>0.05). The accuracy of MSCT in morphological classification was 100% (30/30) in this study group. Conclusion: MSCT can make accurate diagnosis of Bismuth-Corlette classification and morphological classification, which is helpful in preoperative respectability assessment of hilar cholangiocarcinoma. (authors)

  4. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    International Nuclear Information System (INIS)

    Liang Xin; Jacobs, Reinhilde; Hassan, Bassam; Li Limin; Pauwels, Ruben; Corpas, Livia; Souza, Paulo Couto; Martens, Wendy; Shahbazian, Maryam; Alonso, Arie

    2010-01-01

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  5. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xin, E-mail: Xin.Liang@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); College of Stomatology, Dalian Medical University (China); Jacobs, Reinhilde, E-mail: Reinhilde.Jacobs@uz.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Hassan, Bassam, E-mail: b.hassan@acta.n [Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam (Netherlands); Li Limin, E-mail: Limin.Li@uz.kuleuven.b [Department of Paediatric Dentistry and Special Dental Care, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Pauwels, Ruben, E-mail: Ruben.Pauwels@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Corpas, Livia, E-mail: LiviaCorpas@gmail.co [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Souza, Paulo Couto, E-mail: Paulo.CoutoSouza@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Martens, Wendy, E-mail: wendy.martens@uhasselt.b [Department of Basic Medical Sciences, Faculty of Medicine, University of Hasselt, Diepenbeek (Belgium); Shahbazian, Maryam, E-mail: Maryam.Shahbazian@student.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Alonso, Arie, E-mail: ariel.alonso@uhasselt.b [Department of Biostatistics and Statistical Bioinformatics, Universiteit Hasselt (Belgium)

    2010-08-15

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  6. Experimental study of quantity to be taken as patient dose in helical multi-slice CT scan

    International Nuclear Information System (INIS)

    Liu Lantao; Wei Kedao; Yue Brorong; Wang Jianchao

    2009-01-01

    Objective: To bring forward a novel quantity which is used to be taken as effective dose in helical multi - slice CT scan and to validate it by experiment. Methods: Dot chamber and pencil-chamber were used to measure the doses which were performed under axial mode and helical multi-slice mode. Then the readings of doses were compared and analyzed. Results: The dose reading from dot chamber was close to the one from pencil - chamber under axial mode. The ratio is 1.14 for the readings from dot chamber under two scan modes and is 2.88 for the readings from pencil-chamber under two scan modes. Conclusions: The dose measured from dot chamber is an effective quantity to be taken as effective dose. However it is insufficient that the CTDI and DLP be used to be taken as effective dose as the limitation of pencil-chamber in length. (authors)

  7. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  8. Application of low dose multi-slice helical CT in orbital trauma patients

    International Nuclear Information System (INIS)

    Yang Rui; Dai Limei; Li Jianying; Wang Fengyan; Du Guoquan

    2010-01-01

    Objective: To investigate the most appropriate low radiation dose in multi-slice CT (MSCT) scans for orbital trauma patients. Methods: Thirty trauma patients with suspected orbital fractures who underwent helical CT scans with a 64-MSCT using regular dose were selected. Noise was artificially introduced to the axial images using an image space noise addition tool to simulate 6 sets of lower dose scans with tube current of 30, 70, 100, 140, 170 and 200 mA, respectively. The lowest tube current with adequate image quality for confident diagnosis was determined based on the evaluation of the overall image quality and fracture detection on images at different dose levels. The determined lowest tube current was then validated using clinical scans. Radiation dose related parameters CTDIvol, DLP, ED were also recorded. Image quality was evaluated according to its low-density resolution, noise and structure clarity and characterized into 5-grades of excellent, good, fair, worse and worst. Rank sum test and χ 2 test were used for statistics. Results: In 30 trauma patients with regular dose of 300 mA, there were 30 cases of orbital fracture, 19 cases of intraorbital emphysema, 12 cases of ocular muscle injury and 1 case of intraorbital foreign body. These changes could still be clearly observed and correctly diagnosed when the tube current was reduced to as low as 70 mA. However, the overall image quality was mostly fair. At the simulated dose of 100 mA, the majority of images were characterized as excellent or good, and there was no statistical difference compared with that of regular dose scans (P>0.05). In the clinical evaluation for 20 orbital trauma patients with the reduced tube current of 100 m A , the majority of images were judged to be excellent (9 cases) or good (17 cases) and fair (4 cases). The radiation dose (0.29 mSv) was reduced by 70% compared with that of regular tube current of 300 mA (0.86 mSv). Conclusion: The tube current of MSCT may be used as low as

  9. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  10. Clinical application of multi-slice helical CT volumetric scanning in lumber spine

    International Nuclear Information System (INIS)

    Wang Ling; Ge Yinghui; Zhu Shaocheng; Zhang Ming; Cheng Tianming; Lei Zhidan; Lv Chuanjian; Sun Xiaoping; Wu Minghui; Guo Ying; Ma Qianli; Wen Zeying

    2008-01-01

    Objective: To evaluate the clinical application value of multi-slice helical CT volumetric (VH) scanning in lumber spine. Methods: One thousand of patients with back and leg pain who underwent CT examinations were selected as subjects. We simulated the traditional protocol of single-slice(SS) discrete scanning for L3/4, L4/5, and L5/S1 intervertebral discs. The VH scanning mode was performed with 120 kV, 210 mAs, pitch of 1.5 and coverage of 97.5 mm. The simulated SS scanning mode was performed with 120 kV, 240 mAs and coverage of 45.0 mm. The diagnostic outcomes and the radiation doses were compared between the two scanning modes. Two groups doctors observed ten terms, including the osseous spinal stenosis, narrowed intervertebral space and so on in two scanning modes respectively. Then consistency analysis of the data was carded out. Results: The VH scanning mode showed far more features than the SS mode. The detection rates of the VH mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, narrowed lateral recess, vertebral lesion, hypertrophy of L5 transverse process, abnormal direction of facet, facet degeneration, lumbar spondyloschisis, and paraspinal soft tissue were 11.8% (n=118), 38.5% (n=385), 9.3% (n=93), 46.8% (n=468), 31.4% (n=314), 5.7% (n= 57), 25.4% (n=254), 49.7% (n=497), 9.9% (n=99), and 0.6% (n=6) respectively, while the detection rates of the SS mode in ten terms were 5.6% (n=56), 0, 0.6% (n=6), 27.9% (n=279), 22.4% (n=224), 1.2% (n=12), 16.7% (n=167), 37.2% (n=372), 0.5% (n=5), and 0.2% (n=2) respectively. The difference between the two groups had statistically significance (average P 0.05). The detection rates of the VH mode were higher than the SS mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, lumbar spondyloschisis, being 6.2% (n=62), 38.5% (n=385), 8.7% (n=87), and 9.4% (n=94), respectively. In addition, VH mode only partially showed the articular

  11. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  12. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    Science.gov (United States)

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  13. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  14. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  15. Multi-slice Computed Tomography Appearance of Abscess of Cavum Septum Pellucidum: A Case Report and Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Vasudev, M.K.; Chavan, R.G.; Nagarajan, K.; Shukla, D.; Devi, B.I. [National Inst. of Mental Health and Neurosciences, Bangalore (India). Depts. of Neuroimaging and Interventional Radiology and of Neurosurgery

    2006-04-15

    Abscesses involving the cavum septum pellucidum are rare and, owing to their location, detection may be difficult with routine conventional computed tomography (CT). Only a few isolated cases have been reported and mostly in children. We report a case of abscess involving the cavum septum pellucidum in an adult and its appearance on multi-slice spiral CT Abscess, cavum septum pellucidum, multi-slice CT, surgery.

  16. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  17. Studies on intracranial collateral circulation with multi-slice CT angiography in patients with symptomatic cerebral artery stenosis

    Directory of Open Access Journals (Sweden)

    Shu-qing ZHOU

    2011-06-01

    Full Text Available Objective To explore the features of intracranial collateral circulation in patients with symptomatic cerebral artery stenosis.Method Ninety-four patients with ischemic cerebrovascular disease admitted from Apr.2004 to Jun.2009 were involved in present study.All the patients were examined with cerebral multi-slice CT angiography,and the features of cerebral artery stenosis and intracranial collateral circulation were evaluated using maximum intensity projection(MIP and volume rendering(VR images of CT angiography.Result Of the 94 patients involved,48 were diagnosed as cerebral artery stenosis,including 29 cases of cerebral infarction,18 of transient ischemic attack(TIA and 1 of moyamoya disease(MMD.Among the 14 cases of severe cerebral artery stenosis or occlusion,cerebral infarction was found in 6 cases with lesser intracranial collateral vessels(including massive cerebral infarction in 4 cases and watershed infarction in 2 cases,and focal infarction of central semi-ovale in 1 case and TIA in 7 cases were found with abundant intracranial collateral vessels.Multiple lacunar infarction was found in 22 cases of mild or moderate cerebral artery stenosis,but there was no significant correlation between the stenosed arteries and infarction sites.Abundant intracranial collateral vessels were found in one patient with Moyamoya disease but no infarction was observed.Conclusions Intracranial collateral circulation plays an important role of compensation in patients with severe cerebral artery stenosis or occlusion.Cerebral angiography with multi-slice CT is of great significance in evaluation of cerebral artery stenosis and intracranial collateral circulation.

  18. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0

  19. Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Hara, Ryusuke; Yanagi, Takeshi; Sharp, Gregory C.; Kumagai, Motoki; Asakura, Hiroshi; Kishimoto, Riwa; Yamada, Shigeru; Kandatsu, Susumu; Kamada, Tadashi

    2009-01-01

    Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors.

  20. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  1. Assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images

    Directory of Open Access Journals (Sweden)

    Habibeh Farazdaghi

    2017-02-01

    Full Text Available Background and Aims: Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. The aim of this study was the assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images. Materials and Methods: For volumetric analysis, axial paranasal sinus CT scan with 3-mm slice thickness was used. For this study, 80 images (40 women and 40 men older than 18 years were selected. For the assessment of sphenoid sinus volume, Digimizer software was used. The volume of sphenoid sinus was calculated using the following equation: v=∑ (area of each slice × thickness of each slice. Statistical analysis was performed by independent T-test. Results: The mean volume of sphenoid sinus was significantly greater in male gender (P=0.01.The assessed Cut off point was 9/35 cm3, showing that 63.4% of volume assessments greater than cut off point was supposed to be male and 64.1% of volumetry lesser than cut off point were female. Conclusion: According to the area under Roc curve (1.65%, sphenoid sinus volume is not an appropriate factor for differentiation of male and female from each other, which means the predictability of cut off point (9/35 cm3 is 65/1% close to reality.

  2. Study of the usefulness of large intestine screening inspections using multi-slice CT (MSCT)

    International Nuclear Information System (INIS)

    Yamasaki, Michihiro; Nonogaki, Hidehiko; Hara, Koji; Naruse, Yutaka; Hara, Hiroto; Suematsu, Seiji; Yanase, Tadahiko; Otou, Taiji

    2005-01-01

    CT-colonography (CT-C), a new diagnostic imaging technique for cancer of the large intestine-which is increasing rapidly owing to westernized eating habits-has advanced from the developmental stage to the stage of practical application, thanks to progress in MSCT and workstation development. Therefore, based on the results of CT-C application using 16 lines of MSCT to a screening test, we reviewed the usefulness of CT-C in our clinic. We supplemented defective depiction, and found that change of position was effective for virtual image exclusion. We consider that CT-C can support diagnosis if the target of screening tests is a polypoid lesion of more than 6 mm. In addition, it is expected that the number of examinations performed during office visits will increase because of the decreased invasiveness of the procedure, its lack of pain, and its ability to provide early lesion detection. (author)

  3. Biliary complications after liver transplantation: diagnosis with multi-slice CT

    International Nuclear Information System (INIS)

    Zhu Kangshun; Meng Xiaochun; Xu Changmou; Shen Min; Qian Jiesheng; Pang Pengfei; Guan Shouhai; Jiang Zaibo; Shan Hong

    2009-01-01

    Objective: To evaluate multislice CT in the diagnosis of biliary complications after liver transplantation. Methods: Eighty-three consecutive patients who had undergone orthotopic liver transplantation (OLT) presented with clinical or biochemical signs of biliary complications and underwent contrast-enhancement CT examination. Three experienced radiologists, who were blinded to patient's clinical data, assessed CT images for the detection of biliary complications in consensus. Diagnostic confirmation of biliary complications was obtained with direct cholangiography in 69 patients, histologic study in 11 patients and hepaticojejunostomy in 3 patients. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for the detection of biliary complications were calculated. In addition, CT features of anastomotic biliary stricture (ABS) were compared with those of non-anastomotic biliary stricture (NABS) using χ 2 test. Results: A total of 62 biliary complications (74.7%) was eventually confirmed in the 83 patients, including ABS in 32 patients, NABS in 21 patients, biliary duct stones in 16 patients (of which 12 patients with biliary stricture) , anastomotic bile leakage in 5 patients, biloma in 4 patients with biliary stricture, and biliogenic abscess in 2 patients with biliary stricture. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for the detection of biliary stricture were 90.6%, 86.7%, 89.2%, 92.3% and 83.9%, respectively. Other biliary complications, including biliary duct stones (16 cases), anastomotic bile leak (5 cases), biloma (4 cases), and biliogenic abscess (2 cases), were correctly diagnosed by CT; there was no false-positive or false-negative result. The incidence of irregular dilatation of bile duct was 71.4% (15/21), which was significantly higher in NABS cases than in ABS of 25.0% (8/32, P<0.01); whereas the incidence of extrahepatic biliary dilatation

  4. Low-dose multi-slice CT (LMCT) assessment of pulmonary emphysema in public-school teachers

    International Nuclear Information System (INIS)

    Horiuchi, Noriaki; Yamazaki, Yasuhiro; Fujita, Jiro; Suemitsu, Ichizou; Kamei, Tadashi; Tada, Shinya; Ueda, Nobuo

    2003-01-01

    Although rates of emphysematous change in smokers have been reported previously, the precise effects of smoking on emphysematous change have not been established because the study subjects of previous reports were heterogeneous. This study was designed to determine the incidence of emphysematous change identified by low-dose multi-slice CT (LMCT) imaging in public-school teachers. We reviewed 1776 consecutive subjects (ages from 31 to 61 years) who had undergone LMCT scanning during health care examinations. In addition, their replies to questionnaires about smoking were obtained. Emphysematous change was found by LMCT imaging in 22 male smokers. In these 22 smokers, the scores of emphysematous change according to Goddard's method was well correlated with smoking history. According to the questionnaires, the smoking rates of male and female teachers were 56.7% and 4%, respectively. Eighty-five percent of the teachers worked in offices separated from smokers. Most smokers wished to quit smoking and most teachers knew the risk of nicotine as well as the rate of smoking among high school students. However, knowledge of the relationships between smoking and lung cancer, myocardial infarction, and subarachnoid hemorrhage were not adequate. Our present study clearly demonstrated the incidence of emphysematous change in school teachers. In addition, early exposure to information about the risks of smoking is believed to be important for students, but school teachers did not have enough of such information. (author)

  5. Approximations of noise covariance in multi-slice helical CT scans: impact on lung nodule size estimation.

    Science.gov (United States)

    Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J

    2011-10-07

    Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.

  6. Segmentation algorithm of colon based on multi-slice CT colonography

    Science.gov (United States)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  7. A comparison of shielding calculation methods for multi-slice computed tomography (CT) systems

    International Nuclear Information System (INIS)

    Cole, J A; Platten, D J

    2008-01-01

    Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. Additionally, more recent shielding methods have been proposed by the NCRP (National Council on Radiation Protection) from the USA. Thermoluminescent detectors (TLDs) were placed in three CT scanner rooms at different positions for several weeks before being processed. Patient workload and dose data (DLP: the dose length product and mAs: the tube current-time product) were collected for this period. Individual dose data were available for more than 95% of patients scanned and the remainder were estimated. The patient workload data were used to calculate expected scatter radiation for each TLD location by both the NCRP and BIR-IPEM methods. The results were then compared to the measured scattered radiation. Calculated scattered air kerma and the minimum required lead shielding were found to be frequently overestimated compared to the measured air kerma, on average almost five times the measured scattered air kerma.

  8. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  9. Assessment of colonic disease by multi-slice CT pneumocolon after incomplete colonoscopy

    International Nuclear Information System (INIS)

    Zhao Zehua; Liu Wenjin; Xu Songsen; Wang Kang; Wang Weizhong

    2004-01-01

    Objective: To evaluate the use of preoperative MSCT in patients with clinically suspected colorectal disease after incomplete colonoscopy. Methods: After incomplete colonoscopy, 31 patients underwent MSCT before and after intravenous injection of iodinated contrast agent. CT virtual colonography (CTVC), multiplanar reformation (MPR), shaded surface display (SSD), and Raysum images were obtained by using 4 different software in workstation. The results of MSCT were compared with the findings of colonoscopy, intraoperative colon palpation, and postoperative pathology. Results: After incomplete colonoscopy, MSCT was successfully performed in all 31 cases. Postoperative pathology revealed 22 colorectal cancers (one synchronous cancers, two with polyps) and 9 benign disease. 22 colonic carcinomas were all correctly diagnosed by MSCT (including synchronous disease), 2 benign diseases were misdiagnosed as malignancy, and one polyp was missed. Conclusion: MSCT is a feasible and useful method for evaluating the entire colon before surgery in patients with occlusive disease. (author)

  10. Establishing a pattern of 64-multi slice CT of polytraumatic patients

    International Nuclear Information System (INIS)

    Richter, B.; Walecka, A.; Burak, M.; Pakulski, C.

    2009-01-01

    Background: Due to great technological progress made over the last decade in computer tomography, CT Has become a very successful tool for diagnostic imaging in polytraumatic patients. The purpose of this study is an optimum selection of parameters to detect all post-traumatic pathologies in polytraumatic patients, with the application of minimum ionizing radiation. Material/Methods: 131 patients with a suspected polytrauma were studied following various scanning patterns with a 64-slice CT of the head, neck, thorax and abdominal cavity with pelvis. The patients were divided into three groups in accordance with the chosen scheme. Materials were analyzed with the following in view: increasing the efficacy of detecting pathologies, decreasing radiation dose, simplifying assessment and facilitating image archiving. Results: The following mean numbers of serious post-traumatic pathologies were diagnosed during one examination: group I - 1.8, group II - 2.8, and group III - 2.1. There was a statistically significant reduction in the number of reconstructions performed during one examination from 11.8 in group I, 8.3 in group II, to 7.2 in group III. Additionally, statistically significant reductions were obtained in the mean values of the dose-length product (DLP): 3361 mGy · cm (group I), 2805 mGy 8· cm (group II), 2583 mGy · cm (group III). Conclusions: The third scanning pattern, which comprised multiple adjacent sections scanned jointly, including a single trunk scan following the administration of a contrast material, is best in terms of evaluation comfort and the lowest radiation dose absorbed by the patient. Patterns II and III are most effective in detecting pathologies. (authors)

  11. A differentiated approach to the diagnosis of pulmonary embolism and deep venous thrombosis using multi-slice CT

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Stargardt, A.; Haage, P.; Guenther, R.W.; Sinha, A.M.; Schaller, S.

    2002-01-01

    Purpose: To establish a differentiated protocol for multi-slice CT (MSCT) examinations in cases of clinically suspected pulmonary embolism (PE) using pulmonary CT-angiography (CTA) and indirect CT-phlebography (CTP). Materials and Methods: 161 patients with suspected PE were examined using an MSCT (SOMATOM Volume Zoom; Siemens, Forchheim, Germany). After intravenous administration of 120 ml of contrast material, a thin collimation chest-CT scan was performed (120 kV, 100 mAs, collimation: 4 x 1 mm). If PE was present, or previous examinations and clinical signs suggested deep venous thrombosis (DVT), a CTP was subsequently completed. CTPs were performed using a 4 x 5 mm protocol (120 kV, 170 mAs). Venous phase scanning, starting from the pelvic crest, was completed in the popliteal fossa three minutes after contrast material injection. In 73 extremities, CTP were compared to the results of ultrasound, phlebography and autopsy. Scan ranges were documented in all patients. Cumulative doses were calculated for male and female subgroups. Results: 62 patients in our series suffered from PE and in 47 of these patients deep venous thrombosis was seen additionally. Of the 99 patients without PE, 47 also received indirect CTP. CTP confirmed the suspicion and extent of DVT in 8 patients. Only in 2 of 39 patients (5.1%) was previously unknown DVT found, despite the exclusion of PE. Regarding DVT, sensitivity was 94.3% and specificity was 92.1% for indirect CTP. Cumulative chest CT doses averaged 3.3 mSv for males and 4.2 mSv for females, the calculated CTP dosage was 9.3 mSv (according to ICRP 60). Conclusions: the examination protocol presented its suitable for clinical usage in patients with suspected PE. If PE is confirmed, indirect CTP is justified, so that detailed information of the venous system can be obtained. However, the relatively high radiation dosage of an additional CTP requires a strict indication regiment in patients with a negative CTA. (orig.) [de

  12. Experimental study of multi-slice CT for the evaluation of atherosclerotic plaques

    International Nuclear Information System (INIS)

    Tang Xiang; Lv Bin; Wu Wenhui; Lu Jinguo; Dai Ruping; Bai Hua; Tang Yue; Lv Fengying; Jiang Shiliang

    2009-01-01

    Objective: To evaluate the diagnostic values of MSCT for detecting atherosclerotic plaques on New Zealand rabbits models in comparison with pathologic results. Methods: Fifteen New Zealand rabbits were enrolled in this study, including 5 with balloon injury and high-fat diet (group A), 5 with high-fat diet only (group B) and 5 with regular feed (group C). 16th week late, contrast-enhanced MSCT scan was performed in all rabbits with 16 slice MSCT (16-MSCT) in group A and 64 slice MSCT (64-MSCT) in group B and C. The CT and pathological findings were compared in a double-blind manner. The sensitivities and specificities of 16-MSCT and 64-MSCT for detecting atherosclerotic plaques were evaluated by using Fisher test and χ 2 test. Results: Sixty and seventy-five images on 16-MSCT and 64-MSCT had corresponding pathological slices. The sensitivities for the detection of plaques on 16-MSCT and 64-MSCT were 41.5% (22/53) and 64.9% (24/37), and specificities of 85.7% (6/7) and 89.5% (34/38), respectively. Conclusions: 64-MSCT has a higher sensitivity in the detection of atherosclerotic plaques than 16-MSCT. Both scanners can be used to preclude the diagnosis of atherosclerosis. (authors)

  13. Dual-phase contrast enhancement multi-slice CT in grading pancreatic neuroendocrine tumors

    International Nuclear Information System (INIS)

    Zhou Yan; Liu Jianyu; Zhu Xiang

    2013-01-01

    Objective: To evaluate characteristic clinical and imaging findings of pancreatic neuroendocrine tumors (NET) in dual-phase contrast enhancement MSCT. Methods: The dual-phase contrast enhancement MSCT images of 23 lesions in 20 patients with histologically confirmed pancreatic NET were studied retrospectively. Their clinical presentations, imaging characters as well as the intensities of lesions and normal pancreas in each phase were measured, and the following indices were calculated. First, the absolute enhancement of lesions, including the increasing of CT value of the maximum enhancement area within a tumor in arterial phase, that was named A1 in short, and that of the minimum enhancement area was labeled as A2. The same ROI measured increasing CT values in portal venous phase was labeled as V1 and V2 respectively. Secondly, the relatively enhancement indices comparing with the normal pancreas in the same patient within the same phase were calculated. This included the differences between the maximum, as well as the minimum, enhancement areas of tumors and the normal pancreas in arterial phase, which was named as AP1 and AP2 respectively, and those differences in portal venous phase, which were labeled as VP1 and VP2 respectively. All of the tumors were graded as G1 to G3 according to the WHO classification in 2010. A Kruskal Wallis test were performed to compare differences of tumor diameters and the enhancement indices. The change trend of enhancement indices varying with pathology grading were described. Fisher exact test was used to find differences of clinical and imaging characters. Results: Twenty-three lesions in 20 patients included 13 lesions in grade 1 (G1), 8 in G2, and 2 in G3. Among the 10 patients with G1 NET, 7 of them had no endocrine symptoms, while the other 3 had endocrine symptoms. Six of them had no abdominal pain, while 4 of them complained of it. All of the 10 patients with G1 NET had no hepatic metastasis. Among 8 patients with G2 NET

  14. 16 multi-slice CT three-dimensional and multiplanar reconstruction for evaluation of pediatric congenital scoliosis

    International Nuclear Information System (INIS)

    Peng Yun; Zhang Ningning; Zhang Xuejun; Sun Guoqiang; Zeng Jinjin

    2006-01-01

    Objective: Our study is to use of 16 MSCT three-dimensional images and multiplanar reconstruction images in the preoperative investigation of patients with congenital scoliosis, to study its technical advantage and work out surgical plan. Methods: Twenty-seven pediatric patients with congenital scoliosis processing between April to October 2004 were reviewed, including 13 boys and 14 girls. X-ray plain film and sixteen multi-slice CT examination on curved/standard multiplanar reconstruction and three- dimensional computed tomographic imaging may offer, many potential advantages for defining congenital spine anomalies liable to cause progression of scoliosis, including visualization of the deformity in any plane, from any angle, with the overlying structures subtracted. Results: Ten patients had segmentation defects, 6 patients underwent formation defects, 11 patients had complex, unclassifiable anomalies. The patients of rib deformity were found in 15 patients, the most prominent part of the rib cage deformity was at the same level as the most rotated vertebra in 7 patients; 8 patients had vertebral anomalies accompanied with diastematomyelie, including 6 patients with uncompleted or completed bony spur. In 19 of 27 cases, the muhiplanar reconstruction and three-dimensional images allowed identification of unrecognized malformations and completely evaluated the degree of scoliosis, during conventional X-ray images and axial CT images, including volume 3D imaging evaluated approximately classification and modality of complex anomalies in 11 cases, which were unclassifiable malformation in 7 cases and unsegmented bar with contralateral hemivertebrae; 4 children had segmentation defects revealed unilateral unsegmented bar (3 cases) and bilateral block vertebra (1 case) in volume 3D reconstruction images; 2 children were found occultation hemivertebrae which were not been discovered during conventional X-ray images and axial CT images; and 2 children were revaluated

  15. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun

    2013-12-01

    Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.

  16. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  17. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Honda, Eiichi; Tetsumura, Akemi; Kurabayashi, Tohru

    2011-01-01

    Purpose: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases. Materials and methods: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom. Results: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64x) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64. Conclusions: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases.

  18. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Lei Zhen, E-mail: leizhen2004@163.com [Department of Anatomy, Chinese Medical University, No. 92, Beiermalu Road, Heping District, Shenyang, 110001 (China) and Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Ma Heji, E-mail: maheji9831@sina.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xu Na, E-mail: xuna821230@sohu.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xi Huanjiu, E-mail: xihuanjiu2004@yahoo.cn [Anthropology Institute, Liaoning Medical College, No. 40, Sanduan, Songpo Rd, Jinzhou, 121001 (China)

    2011-05-15

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  19. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    International Nuclear Information System (INIS)

    Lei Zhen; Ma Heji; Xu Na; Xi Huanjiu

    2011-01-01

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  20. Study of low dose and dynamic multi-slice CT about obstructive sleep apnea syndrome in sleeping

    International Nuclear Information System (INIS)

    Shen Jie; Qi Ji; Yin Jianzhong

    2006-01-01

    Objective: To perform Low dose dynamic MSCT(multi-slice CT) in sleeping obstructive sleep apnea syndrome (OSAS) patients correcting the imprecise measure values in waking state, and to exactly analyse the location and extension of the dynamic changes about the condition. Methods: Sixteen OSAS patients were scanned both in waking and naturally sleeping period (end phase of inspiration and expiration). Measured at the narrowest part of the retropalatal (RP) and retroglossal (RG) and 5 mm under the tip of epiglottis at the epiglottal (EPG)at the end period of inspiration in sleeping, respectively, and compared the accurate position of the narrowest or occlusive level in 3 phases. All patients were also scanned using cine mode at the narrowest level at the end period of inspiration in sleeping to show the pharyngeal cavity changes during sleep. Results: The smallest XSA of RP region (M w =47.50 mm 2 , M e =73.00 mm 2 , M i =2.00 mm 2 ; Z we =2.897, P we =0.003; Z wi =4.192, P wi ie =4.538, P ie w =8.00 mm, M e =9.50 mm, M i =1.50 mm; Z we =1.933, P we =0.056; Z wi =3.720, P wi ie =4.230, P ie w =8.00 mm, M e =9.00 mm, M i =1.00 mm; Z we =1.210, P we =0.246; Z wi =4.203, P wi ie =4.557, P ie w =4.00 mm 3 , M e =5.50 mm 3 , M i =1.50 mm 3 ; Z we =1.576, P we =0.125; Z wi =3.532, P wi ie =4.077, P ie w =7.00 mm, M e =6.00 mm, M i =10.50 mm; Z we =0.557, P we =0.603; Z wi =2.541, P wi =0.011; Z ie =2.852, P ie =0.004) and RG regions (M w =5.00 mm, M e =3.00 mm, M i =9.50 mm; Z we =0.747, P we =0.482; Z wi =2.657, P wi =0.007; Z ie =3.075, P ie =0.001), were different between inspiration and expiration of sleeping or awake. The dynamic cine CT scan during sleeping could show pharyngeal change, clearly. Conclusion: At the end period of inspiration in sleeping, the location of narrow or obstructive of airway is the most precise and sensitive and the false negative at the waking could be obviously reduced. Low dose MSCT scan reduced exposure and expense. (authors)

  1. Study on bone mineral density and bone structure of lumbar vertebrae in osteoporotic elderly women with multi-slice CT

    International Nuclear Information System (INIS)

    Wu Shengyong; Qi Ji; Wang Bin; Wen Lianqing

    2005-01-01

    Objective: To evaluate the ability of volumetric bone mineral density (BMD) parameters of lumbar vertebrae in differentiating osteoporotic fractured from nonfractured elderly women with vQCT technique, and to compare the bony structural conditions of osteoporotic elderly women with healthy elderly women. Methods: Multi-slice CT spinal scans of L1 and L2 were acquired in 26 osteoporotic vertebral fractured elderly women (group one) and 30 nonfractured osteoporotic subjects (group two). All the retro-reconstructed images of L1 and L2 were sent to the workstation and processed by volume rendering (VR) technique to measure volumetric BMD (3D-INTGL, 3D-CORT, 3D-TRAB) and trabecular and integral BMD (2D-TRAB, 2D-INTGL) by conventional QCT technique. BMD indexes in DXA were AP-SPINE and bone mineral apparent density (BMAD) in anteroposterior position. The seven parameters between the two group s were compared. Ten healthy elderly women were selected as normal group to reformate 3D-VR images from MSCT images to analyze the bony structure and calculate the ratio of bone volume to total volume (BV/TV) in the center of L1 vertebrae, and to compare the index between the normal group and tenpatients randomly selected from the 56 osteoporotic women. Results: DXA measurements in group one: AP-SPINE and BMAD were (0.796±0.170)g/cm 2 and (272.7±27.7) mg/cm 3 , respectively, showing no statistically significant differences comparing with (0.817±0.140) g/cm 2 and (249.5 ± 26.5) mg/cm 3 in group two. Volumetric BMD in group one included 2D-TRAB (70.4 ± 22.2) mg/cm 3 , 2D-INTGL (138.3±35.1) mg/cm 3 , 3D-INTGL (139.4±34.9 ) mg/cm 3 , 3D-CORT (133.8±26.9) mg/cm 3 , and 3D-TRAB (69.9 ±18.6) mg/cm 3 , respectively, showing statistically differences with (89.1±21.8) mg/cm 3 , (170.6±34.5) mg/cm 3 , (180.5±28.2) mg/cm 3 , (163.2±27.5) mg/cm 3 , and (83.8 ± 17.1) mg/cm 3 in group two (the decrements 18%-23%). The mean value of BV/TV of L1 vertebrae was (8.12 ± 1.96)% in

  2. Quantitative assessment of pulmonary function using low dose multi-slice spiral CT in smoker

    International Nuclear Information System (INIS)

    Chen Huai; Zeng Qingsi; Zheng Jinping; Guan Yubao; Zhang Chaoliang; Cen Renli

    2012-01-01

    Objective: To evaluate the clinical feasibility of low dose MSCT for quantitative assessment of pulmonary function in smokers. Methods: One hundred and forty-six patients with chronic objective pulmonary disease (COPD) including 109 smokers (74.6%) and 37 non-smokers (25.3%) underwent pulmonary function test and low-dose MSCT scan. All data were analyzed using computer-aided lung analysis software. Pulmonary function parameters from low-dose MSCT were compared between smokers and non-smokers and also compared with pulmonary function test in non-smokers (Pearson test). Results: In smokers, the average volume at full inspiratory phase (Vin) was (5125 ± 862 ) ml, mean lung attenuation was (-902 ± 26) HU, mean lung density was (0.0984 ± 0.0260 ) g/cm 3 , emphysema volume was (2890 ±1370) ml. The average volume at full expiratory phase (Vex) was (2756 ±1027) ml, mean lung attenuation was (-811 ±62) HU, mean lung density was (0.1878 ±0.0631) g/cm 3 , emphysema volume was (685 ±104) ml. In non-smokers, the average Vin was (3734 ± 759) ml, mean lung attenuation was (-876 ±40) HU,mean lung density was (0.1244 ±0.0401)g/cm 3 , emphysema volume was ( 1503 ± 1217) ml. The average Vex was (1770 ± 679) ml, mean lung attenuation was (-765 ± 56) HU, mean lung density was (0.2360 ± 0.0563) g/cm 3 , emphysema volume was (156 ± 45) ml. There were significant differences between smokers and non-smokers (P<0.01). The Vex/Vin was correlated with residual volume/total lung capacity (RV/TLC, r=0.60, P<0.01), and Vin was correlated with TLC (r=0.58, P<0.01), Vex with RV (r=0.59, P<0.01). Pixel index (PI) -950 in was correlated with FEV 1% pre and FEV1/FVC% (r=-0.53, -0.62, respective, P<0.01), Pl-950ex was correlated with FEV1 % pre and FEV1/FVC% (r=-0.71, -0.77, respective, P<0.01). Conclusion: Low-dose MSCT can be a potential imaging tool for quantitative pulmonary function assessment in smokes. (authors)

  3. Evaluation of experimental cartilage lesions with ultrahigh-resolution multi-slice-CT in comparison to histology

    International Nuclear Information System (INIS)

    Stork, A.; Kemper, J.; Begemann, P. G. C.; Habermann, C.R.; Adam, G.; Priemel, M.; Kummer, T.; Amling, M.

    2004-01-01

    Purpose: histologic validation of ultrahigh-resolution multislice (MS)-CT for the evaluation of focal, experimental cartilage lesions with special regard to the subchondral bone. Testing of micro-CTCT) as alternative reference standard. Methods: 32 experimental cartilage lesions in bovine patellae were imaged surrounded by air (MS-CT-air) and immersed in a contrast material solution (MS-CT-CM) with MS-CT (collimation 2 x 0,5 mm). After the μCT (8 μm-voxelsite) examination in three specimen and histologic work-up of 29 specimen two radiologist graded the defects on MS-CT images in consensus (subchondral bone involvement yes or no) and results were compared to the results of histomorphometry and μCT. Results: the MS-CT-air and -CM had an accuracy of 94% (30/32) and 88% (28/32), respectively. MS-CT-air led to one false-positive (remaining cartilage: = 0,1 mm) and false-negative result, each. MS-CT-CM showed false-positive results if the remaining cartilage was [de

  4. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  5. Detection and classification of focal liver lesions in patients with colorectal cancer: Retrospective comparison of diffusion-weighted MR imaging and multi-slice CT

    International Nuclear Information System (INIS)

    Eiber, Matthias; Fingerle, Alexander A.; Brügel, Melanie; Gaa, Jochen; Rummeny, Ernst J.; Holzapfel, Konstantin

    2012-01-01

    Objectives: To compare the diagnostic performance of diffusion-weighted MR imaging (DWI) with multi-slice CT (MS-CT) in the detection and classification of focal liver lesions in patients with colorectal cancer. Methods: In a retrospective study 68 patients who underwent DWI at 1.5 T (b-values of 50, 300 and 600 s/mm 2 ) and contrast-enhanced MS-CT were analysed by two radiologists blinded to the clinical results. Imaging results were correlated with intraoperative surgical and ultrasound findings (n = 24), imaging follow-up or PET (n = 44). Sensitivity of DWI and MS-CT in detection of focal liver lesions was compared on a per-lesion and a per-segment basis. Receiver operator-characteristic (ROC) curves to determine the diagnostic performance and the sensitivities of correctly identifying liver metastases on a segmental base were calculated. Results: For lesion detection, DWI was significantly superior to MS-CT both on a per-lesion (difference in sensitivities for reader 1 and 2 22.65% and 19.06%, p < 0.0001) and a per-segment basis (16.86% and 11.76%, p < 0.0001). Especially lesions smaller than 10 mm were better detected with DWI compared to MS-CT (difference 41.10% and 29.45%, p < 0.0001). ROC-analysis showed superiority for lesions classification (p < 0.0001) of DWI (AUC: 0.949 and 0.951) as compared to MS-CT (AUC: 0.879 and 0.892, p < 0.0001 and p = 0.005). DWI was able to filter out metastatic segments with a higher sensitivity (88.2 and 86.5%) compared to MS-CT (68.0 and 67.4%, p < 0.0001 and p = 0.005, respectively). Conclusion: Compared to MS-CT DWI is both more sensitive in the detection of liver lesions and more accurate in determining the extent of metastatic disease in patients with colorectal cancer and therefore might help to optimize therapeutic management in those patients.

  6. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    International Nuclear Information System (INIS)

    Liang Xin; Lambrichts, Ivo; Sun Yi; Denis, Kathleen; Hassan, Bassam; Li Limin; Pauwels, Ruben; Jacobs, Reinhilde

    2010-01-01

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm. Results: The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively. Conclusion: The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.

  7. The measurement of organic radiation dose of multi-slice CT scanning by using the Chinese anthropomorphic chest phantom

    International Nuclear Information System (INIS)

    Peng Gang; Zeng Yongming; Luo Tianyou; Zhao Feng; Zhang Zhiwei; Yu Renqiang; Peng Shengkun

    2011-01-01

    Objective: Using the Chinese anthropomorphic chest phantom to measure the absorbed dose of various tissues and organs under different noise index, and to assess the radiation dose of MSCT chest scanning with the effective dose (ED). Methods: The equivalence of the Chinese anthropomorphic chest phantom (CDP-1 C) and the adult chest on CT sectional anatomy and X-ray attenuation was demonstrated. The absorbed doses of various tissues and organs under different noise index were measured by laying thermoluminescent dosimeters (TLD) inside the phantom, and the corresponding dose-length products (DLP) were recorded. Both of them were later converted into ED and comparison was conducted to analyze the dose levels of chest CT scanning with automatic tube current modulation (ATCM) under different noise index. Student t-test was applied using SPSS 12.0 statistical software. Results: The Phantom was similar to the human body on CT sectional anatomy. The average CT value of phantom are - 788.04 HU in lung, 45.64 HU in heart, 65.84 HU in liver, 254.32 HU in spine and the deviations are 0.10%, 3.04%, 4.49% and 4.36% respectively compared to humans. The difference of average CT value of liver was statistically significant (t=-8.705, P 0.05). As the noise index increased from 8.5 to 22.5, the DLP decreased from 393.57 mGy · cm to 78.75 mGy · cm and the organs dose declined. For example, the average absorbed dose decreased from 22.38 mGy to 3.66 mGy in lung. Compared to ED calculating by absorbed dose, the ED calculating by DLP was lower. The ED values of the two methods were 6.69 mSv and 8.77 mSv when the noise index was set at 8.5. Conclusions: Application of the Chinese anthropomorphic chest phantom to carry out CT dose assessment is more accurate. The noise index should be set more than 8.5 during the chest CT scanning based on ATCM technique. (authors)

  8. Analysis of hepatic vein variations in healthy people with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Zhang Rong; Li Yong; Shen Jun; Zeng Weike; Li Jieting; Huang Suiqiao; Liang Biling; Liu Chao

    2007-01-01

    Objective: To analyze variations of hepatic vein in healthy people with 64-slice spiral CT. Methods: Seventy-five healthy subjects underwent multi-slice spiral computed (MSCT) hepatic venography. The anatomy of the junction of the hepatic veins with the inferior vena cava and the intrahepatic drainage territory of the hepatic veins and tributaries were evaluated. The hepatic veins were classified according to three anatomic classification (Nakamura's, Marcos's and Kawasaki's classification) methods respectively. Results: There was a common trunk of the middle and left hepatic veins before joining the IVC in 86.7% (65/75)of the cases. In 13.3% (10/75)of the cases, the three main hepatic veins joined the IVC separately. The ratios of Nakamma's classification type A, B, C of hepatic veins were 49.4% (37/75), 37.3% (28/75), and 13.3% (10/75) respectively. The ratios of Marcos's classification type A, B, C of hepatic veins were 56.0% (42/75), 24.0% (18/75), and 20.0% (15/75) respectively. The ratios of Kawasaki's classification type I, II of hepatic vein were 40.0% (30/75) and 60.0% (45/75). Conclusion: Multi-slice spiral CT hepatic venography can provide visualization of peripheral hepatic venous branches in details. (authors)

  9. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Jianjun, Li; Renyou, Zhai; Dongpo, Zhang; Qiang, Huang; Dingke, Dai; Ping, Yu; Na, Bao [Department of Radiology, Beijing Chaoyang Hospital, Capital Medical Univ., Beijing (China)

    2008-10-15

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4{+-}15.7)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (293.7{+-} 7.9) ml{center_dot}min{sup -1{center_dot}}100 g {sup -1}, (379.4{+-}14.5)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (382.5{+-}16.6)ml{center_dot}min{sup -1{center_dot}}. 100 g{sup -1}] and [(3.1{+-}0.2)s, (2.6{+-}0.2)s, (2.2{+-}0.1)s, (1.9{+-}0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P<0.01) between groups (A and B, A and C, A and D, B and C, B and D) except between group C and D (the P value >0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2{+-} 19.2)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1} and (259

  10. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Li Jianjun; Zhai Renyou; Zhang Dongpo; Huang Qiang; Dai Dingke; Yu Ping; Bao Na

    2008-01-01

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4±15.7)ml·min -1 ·100 g -1 , (293.7± 7.9) ml·min -1 ·100 g -1 , (379.4±14.5)ml·min -1 ·100 g -1 , (382.5±16.6)ml·min -1 ·. 100 g -1 ] and [(3.1±0.2)s, (2.6±0.2)s, (2.2±0.1)s, (1.9±0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P 0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2± 19.2)ml·min -1 ·100 g -1 and (259.4±15.7) ml·min -1 ·100 g -1 in group A, (393.2±16.1) ml· min -1 ·100 g -1 and (293.7±7.9) ml·min -1 ·100 g -1 in group B] and MTF [(1.8±0.1)s and (3.1±0.2) s in group A, (1.8±0.2) s and (2.6±0.2) s in group B] were statistically different (P 0.05) between groups

  11. Motion estimation and compensation in dynamic spiral CT reconstruction

    International Nuclear Information System (INIS)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St.

    2004-01-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  12. Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography.

    Directory of Open Access Journals (Sweden)

    Richard Nolz

    Full Text Available To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction.The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated.Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09, and in venous sets of 73.3 versus 79.4 (p = 0.15, respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01. Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase.Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.

  13. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  14. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (''ECG pulsing''): phantom measurements

    International Nuclear Information System (INIS)

    Poll, L.W.; Cohnen, M.; Brachten, S.; Moedder, U.; Ewen, K.

    2002-01-01

    To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. Material and methods: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5 mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-Thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ('ECG pulsing') at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of 'ECG pulsing'. Results: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5-1.8 mSv to 1.8-2.1 mSv, using the 2.5 mm collimation, and from 4.6-5.6 mSv to 5.9-7.2 mSv, for protocols using 1 mm collimation. Conclusions: The ECG-controlled tube current modulation allows a dose reduction of 37% to 44% when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate. (orig.) [de

  15. TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

    Energy Technology Data Exchange (ETDEWEB)

    Howansky, A; Peng, B; Lubinsky, A; Zhao, W [Stony Brook University, Stony Brook, NY (United States)

    2016-06-15

    Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of

  16. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  17. Spiral CT for evaluation of chest trauma

    International Nuclear Information System (INIS)

    Roehnert, W.; Weise, R.

    1997-01-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [de

  18. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Avsever, Hakan; Özdemir, Tayfun

    2013-12-01

    The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study. Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA). Radiographic and subjective bone quality classification (BQC) was also classified. Results were analyzed by correlation tests and multiple regressions (p < .05). CBCT-based gray density values (765 ± 97.32 voxel value) outside the implants were significantly higher than those of CT-based values (668.4 ± 110 Hounsfield unit, p < .001). Significant relations were found among the gray density values outside the implants, ITV (adjusted r(2)  = 0.6142, p = .001 and adjusted r(2)  = 0.5166, p = .0021), and RFA (adjusted r(2)  = 0.5642, p = .0017 and adjusted r(2)  = 0.5423, p = .0031 for CT and CBCT groups, respectively). Data from radiographic and subjective BQC were also in agreement. Similar to the gray density values of CT, that of CBCT could also be predictive for the subjective BQC and primary implant stability. Results should be confirmed on different CBCT scanners. © 2012 Wiley Periodicals, Inc.

  19. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  20. Principles of spiral CT: III. Quality assurance

    International Nuclear Information System (INIS)

    Suess, C.; Kalender, W.A.

    1998-01-01

    Since its introduction in 1989 spiral CT has gained wide clinical acceptance and meanwhile it covers a large range of CT applications. This new technology, however, has not yet been recognized and acknowledged in the national or international regulations on scanner quality assurance (QA) programs. The conventional QA procedures should be extended to check the distribution of resolution and noise within the image plane. Imaging performance in the axial direction constitutes one of the major advantages of spiral scanning. Therefore, the slice sensitivity profiles and the spatial and low-contrast resolution along the z-axis have to be assessed. The high demands on table feed accuracy require additional tests. We suggest phantoms and procedures to check and quantify these parameters. Thereby, we hope to support the ongoing discussion about spiral CT quality assurance. (orig.) [de

  1. Spiral CT manifestations of spherical pneumonia

    International Nuclear Information System (INIS)

    Li Xiaohong; Yang Hongwei; Xu Chunmin; Qin Xiu

    2008-01-01

    Objective: To explore the Spiral CT manifestations and differential diagnosis of spherical pneumonia. Methods: 18 cases of spherical pneumonia and 20 cases of peripheral pulmonary carcinoma were selected, both of them were confirmed by clinic and/or pathology. The SCT findings of both groups were compared retrospectively. Results: Main spiral CT findings of spherical pneumonia were showed as followings: square or triangular lesions adjacent to pleura; with irregular shape, blurry, slightly lobulated margin, sometimes with halo sign. Small inflammatory patches and intensified vascular markings around the lesions were seen. Lesions became smaller or vanished after short-term anti-inflammatory treatment. Conclusion: Spherical pneumonia showed some characteristics on Spiral CT scan, which are helpful in diagnosis and differential diagnosis of this disease. (authors)

  2. Diagnosing extracranial atherosclerotic diseases with spiral CT

    International Nuclear Information System (INIS)

    Moran, C.J.; Vannier, M.W.; Erickson, K.K.; Broderick, D.F.; Kido, D.K.; Yoffie, R.L.

    1991-01-01

    This paper reports that this discovery study was performed to determine whether extracranial carotid artery plaques could be diagnosed with a new CT technique (spiral CT) that allows nondistorted three-dimensional (3D) reconstructions in the z axis. Twenty carotid arteries were examined with spiral CT in normal volunteers and in patients suspected of having atherosclerotic plaques in the extracranial carotid arteries. The Somatom Plus CT table was advanced at a constant rate, the x-ray tube was continuously rotated, and 3D data were continuously acquired. Sixty milliliters of nonionic contrast medium was injected intravenously previous to and during the acquisition of data. The carotid bifurcations were identified in all patients. Planar images, similar to conventional intraarterial angiograms, were routinely produced from the volumetric CT data

  3. Multi-slice spiral CT in the diagnosis of congenital heart diseases associated with tracheobronchial stenosis in children

    International Nuclear Information System (INIS)

    Wang Rongpin; Liang Changhong; Huang Meiping; Liu Hui; Cui Yanhai; Liu Qishun

    2010-01-01

    Objective: To explore the diagnostic value of post processing techniques of MSCT for diagnosing congenital heart disease associated with tracheobronchial stenosis in children. Methods: Thirty four patients with congenital heart disease complicated by tracheobronchial stenosis were evaluated with MSCT. MPR, CPR, MinIP and VR were performed to show the tracheobronchial morphology. Findings in 43 segments of 32 cases were compared with the findings of surgical operation. Mann-Whitney test was employed to assess the significance of measurement between the post processing techniques and the operation. Results: The length of stenotic segments were variable seen at operation, with values between 4- 39 mm in trachea, 4-33 mm in main bronchi and 3-12 mm in lobe bronchi, respectively. The biggest difference between the measurement of operation and MSCT was 4 mm (3 segments). Other differences of stenotic segments were within 3 mm. Six segments exhibited mild, 16 moderate and 21 severe stenosis at surgery. By contrast, five segments exhibited mild, 17 moderate and 21 severe stenosis by MPR or CPR, 2 mild, 9 moderate and 32 severe stenosis by MinIP and 4 mild, 11 moderate and 28 sever stenosis by VR, respectively. There was no significant difference in measuring the degree of tracheobronchial stenosis between MPR or CPR, VR and the surgery (Z=-0.105, -1.479; P>0.05), while MinIP frequently overrated the degree of stenosis compared with the measurement at surgery (Z=-2.484, P=0.013). Conclusion: The integrated three dimensional reformations of MSCT scan can accurately evaluate the degree and extent of congenital heart disease associated with tracheobronchial stenosis in children and provide valuable information for clinical management. (authors)

  4. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  5. Kidney spiral CT, indications, realization, results

    International Nuclear Information System (INIS)

    Braunschweig, R.; Beilicke, M.; Hundt, W.; Breiteneder, T.; Reiser, M.

    1999-01-01

    The introduction of spiral computed tomography (spiral CT) has vastly enriched the methodologically diversity of computer-tomographic scans. It allows for the recording of different perfusion or excretion stages of the kidney parenchyma of the urine draining paths by carrying out long-distance, phase-identical multiple examinations of the retroperitoneum. The description of the findings which are characterized by their local and contrasts behavior is possible. The following report describes the indications and technological process of kidney spiral CT using kidney-typical intravenous contrast media. Special emphasis is put on the advantages and limits of multiple phase spiral CT. Decisive preconditions are: 1. Specific clinical query, 2. selection of the corresponding phase contrasts of the kidneys and uretra or bladder, 3. exact technical and temporal adjustment of the acquisition parameters. Scanning times are in the range of seconds. The overall examination can be carried out quick and without any major strain on the part of the patient. A sound proof and a general differentiation of focal kideny lesions can be derived from the acquired data. This is also true for kidneys and ureters findings. Bladder findings can be localized and differentiated according to stage. More than two 'spiral acquisitions' should be carried out with restraint taking exposure to radiation into account. Due to the sound registration of focal lesions, its capability of reproduction and its short-time examination, the spiral CT of the kidneys can be said to be the most effective current scanning method of the retroperitoneum following clinical examinations and sonography. (orig.) [de

  6. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  7. Evaluation of the upper airway measurements by multi-slice CT before and after operations in obstructive sleep apnoea syndrome patients

    International Nuclear Information System (INIS)

    Tao Ping; Dang Yuqing; Chang Bei; Wang Xiao; Jin Zhengyu; Li Wuyi; Huo Hong

    2009-01-01

    Objective: To evaluate the changes of the upper airway of the patients with obstructive sleep apnoea syndrome (OSAS) before and after operations and to know the effects of operations by MSCT. Methods: The upper airway dimensions of 26 patients with OSAS were measured on multiplanar reformatted (MPR), curved-planar reformatted (CPR), volume rendering (VR) images of 16-slice spiral CT. The measurements include the anteroposterior calibres and the areas on the reformatted axial images on the pharyngeal cavity levels, the calibres and the minimum areas in retropalatal and retroglossal regions, the areas of the soft palate and uvula on the reformatted sagittal view with maximum thickness, the maximum wall thickness of the right and left the upper airway on the coronary images, the volume of the upper airway before and after the operations. The measurements were correlated with the polysomnography (PSG) records. The data were analyzed paired-samples t-test and Pearson correlations. Results: By comparison, the anteroposterior calibres and the cross-sectional areas on the reformatted axial view of the lower retropalatal region (slice 4) of the upper airway increased significantly after operations. The anteroposterior diameter increased from 5.9 mm before operations to 12.8 mm after operations, where t=-5.506, P 2 before operations to 275.0 mm 2 after operations, where t=-5.011, P 2 before operations to 128.0 mm 2 after operations, where t=3.087, P 2 before operation to 10.9 mm, 76.0 mm 2 after operation, where t=-3.413, -2.216, respectively and P 2 before operations to 76.0 mm 2 after operations, were t=-4.932, P<0.05. The anteroposterior calibres increased from 4.6 mm before operations to 6.6 mm after operations, where t=-7.308, P<0.05. The L-R calibres increased from 8.3 mm before operations to 13.6 mm after operations, where t=-4.320, P<0.05. Conclusions: MPR, CPR, VR of MSCT can evaluate the not only the morphology but the function changes of the upper airways on the

  8. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  9. The selection of window width and levels for measuring the airway dimensions with spiral CT scan: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huuibing; Wu Gang; Ma Ji; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To investigate the optimal window width and window level for measuring the airway dimensions with spiral CT scan in Japanese white big-ear rabbits so as to lay the foundation for airway stenting in animal experiments. Methods: Multi-slice spiral CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the anteroposterior and transversal diameter of the thoracic trachea, the anteroposterior diameter of the right and left bronchus were measured with lung window, mediastinum window and special fat window separately. The revealing rate of the tracheal wall and the measuring results in different windows and levels were recorded and compared with the anatomical data. The differences of the relevant data were statistically analyzed. Results: With lung window, the tracheal wall was well demonstrated, but the relevant data were smaller than that with mediastinum window. With mediastinum window, the data were bigger and the tracheal wall border appeared blurred. The results obtained with fat window were close to the actual anatomical data. Conclusion: For accurately measuring the anteroposterior and transversal diameter of the thoracic trachea in Japanese white big-ear rabbits with multi- slice spiral CT scan, fat window should be adopted, which is helpful for the preparation of tracheal and bronchial stents. (authors)

  10. Diagnosis of pancreatic tumors by spiral angio CT

    International Nuclear Information System (INIS)

    Miura, Kohi; Nakao, Norio; Takayasu, Yukio; Okawa, Tomohisa

    1995-01-01

    Spiral angio were performed with injection of 30 ml of contrast material at a rate of 1 ml/sec with a scan delay of 6 sec through catheter into the celiac artery while the blood flow of the superior mesenteric artery (SMA) was occluded by the inflated balloon catheter. Spiral CT scans were obtained using Somatom Plus (Siemens). Parameter for spiral CT were 24-sec acquisition time, 5 mm collimation, 5 mm/sec table incrementation. Reconstructions were performed every 5 mm. Pancreatic cancers were characteristically depicted with spiral angio CT as hypodensity relative to normal enhanced pancreatic parenchyma. On dynamic angio CT studies performed in pancreatic cancers, the area of cancer and normal parenchyma had maximum level of enhancement at 10-15 sec after injection of contrast material via catheter into the celiac, and there was no difference in enhancement between tumor and normal parenchyma. On the other hand, the lesions of cancer were revealed as hypodensity with spiral angio CT. In case of chronic pancreatitis, the enhancement of the entire pancreas obtained with spiral angio CT was homogeneous. Insulinoma in the tail of pancreas was detected by spiral angio CT but was not detected by both selective angiography and conventional CT. Three-dimensional (3-D) rendering spiral angio CT data shows the extent of vascular involvement by pancreatic cancer and provides useful information for surgical planning. Spiral angio CT is the most useful procedure for diagnosis of pancreatic tumor. (author)

  11. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  12. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    Energy Technology Data Exchange (ETDEWEB)

    Favazza, C; Yu, L; Leng, S; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  13. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    International Nuclear Information System (INIS)

    Favazza, C; Yu, L; Leng, S; McCollough, C

    2015-01-01

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  14. Optimising imaging parameters in experimental spiral CT

    International Nuclear Information System (INIS)

    Tiitola, M.; Vehmas, T.; Kivisaari, R.P.; Kivisaari, L.

    1997-01-01

    Purpose: This in vitro study was conducted to analyse lesion detection and relative radiation exposure in different CT techniques. Material and Methods: We used a plastic phantom (12 x 8 x 2 cm) containing holes filled with air or fluid of varying densities to simulate lesions. This was imaged with Siemens Somatom Plus S and GE High Speed Advantage units. We varied table feeds (3 and 6 mm/s in Siemens and 3 and 4.5 mm/s in GE) and increments (2 mm and 4 mm) while keeping collimation at 3 mm. The SmartScan program of GE and the reformating algorithm of Siemens were also analysed. To evaluate the different methods, the phatnom lesions were counted by 3 observers. Radiation exposures associated with each technique were also measured. Results: The images reformatted to a coronal direction were significantly inferior (p<0.01) to those in other techniques. The use of SmartScan did not influence lesion detection, nor did changes in pitch or increment. Spiral and non-spiral techniques proved to be equal. Radiation exposure was lowest when a greater pitch or the SmartScan program was used. Conclusion: Radiation exposure in CT can be limited without significantly impairing the image quality by using low-dose techniques. Reformatting to a coronal direction should be used with care as it debases the image quality. (orig.)

  15. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  16. The effect of pitch in multislice spiral/helical CT

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    2000-01-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  17. Multi-slice CT (MSCT) in cardiac function imaging: threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI

    International Nuclear Information System (INIS)

    Ehrhard, K.; Oberholzer, K.; Gast, K.; Mildenberger, P.; Kreitner, K.F.; Thelen, M.

    2002-01-01

    Purpose: To assess MSCT of the heart to determining left ventricular ejection fraction (EF) based on threshold-value-supported 3D volume reconstructions compared to MRI. Methods: Cardiac MSCT was performed in 7 patients. Images were reconstructed during end-systolic and end-diastolic phases of the cardiac cycle and transformed to 3D volumes to determine end-systolic (ESV) and end-diastolic volume (EDV) by using different lower threshold values: besides fixed lower threshold values, identical for each image sequence, individual lower threshold values dependent on contrast enhancement of the left ventricle were applied. The latter represent the mean value calculated by combining the average CT-density of the myocardium and the contrast-enhanced blood in the left ventricle. The EF derived from ESV and EDV. Results: The best correlation with MR imaging was obtained for ESV and EDV by using the individual lower threshold values for the respective sequence. The correlation coefficient for ESV was 0.95 and for EDV it was 0.93. On average, the ESV was overestimated by 3.72 ml, while the ESD was underestimated by 2.85 ml. The respective standard deviation for the ESV was 14,87 ml, for the EDV it was 26.83 ml. On average, the EF was underestimated by 3.57% with a standard deviation of 9.43% and a correlation coefficient of 0.83 in comparison to MRI. Conclusion: The threshold-value-supported 3D volume reconstruction of the left ventricle represents a good method to determine the left ventricular function parameters. Due to the differences in the contrast enhancement, the use of an individual lower threshold value for every image sequence is of particular importance. (orig.) [de

  18. Dose reduction in coronary artery imaging with 64-row multi-slice helical CT with body mass index-dependent mA selection

    International Nuclear Information System (INIS)

    Gao Jianhua; Wang Guisheng; Zheng Jingchen; Li Jianying; Sun Xianchang; Gao Caihong; Dai Ruping

    2008-01-01

    Objective: To evaluate the robustness of body mass index (BMI) adapted tube current selection method for obtaining consistent image quality in MSCT coronary artery imaging. Methods: Initially one hundred patients in the control group (C group) underwent cardiac scans using GE 64-row VCT with standard scan protocol (640 mA, 120 kV, 0.35 sec, body bowtie, C 2 filter). Noise measurement was obtained for each patient using the average of three consecutive slices in the ascending aorta with ROI of 10 mm x 10 mm to establish the relationship between BMI, desired image noise (IN) and required mA. An excel table was established to predict the required mA to achieve a desired IN for each patient with different BMI. A second group of one hundred cardiac patients (L group) was scanned with BMI-adapted mA from the table to evaluate the practicability of this method. BMI, IN, CT dose index (CTDI), effective dose (ED) were all recorded. Results: For the control group of 100 patients, the mean values and standard deviations of image quality score (IQS), BMI, IN and ED were 3.71±0.54, 25.08±2.63, 24.56±5.03 and (17.63±1.68) mSv (with range of 15-22 mSv). Regression analysis indicated linear relationship between BMI and image noise with fixed mA. Using the relationship between tube current and image noise and noise ratio between large bowtie and cardiac bowtie, the following equation for the required tube current Xma to achieve present image noise of INa for patient with certain BMI value when using cardiac bowtie could be then obtained: Xma=Fma x [(k 1 x BMI + c 1 )/Ina] 2 , where Fma=640 mA, k 1 =1.033, c 1 = -3.2, INa=27 in the study. (2) For the patients in L group, the mean values and standard deviations of IQS, BMI, and IN were 3.69±0.53, 25.07±2.91, and 26.61±3.44, respectively. The average tube current used was (469.95±113.45) mA, depending on patient's BMI values. The average effectively dose was (9.08±2.25) mSv. There was no statistically difference between the

  19. Measuring of the airway dimensions with spiral CT images: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huibin; Ma Ji; Wu Gang; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To measure the length, angle and their correlation of the main anatomical dimensions of the trachea and bronchus in experimental Japanese white big-ear rabbits with the help of spiral CT 3D images, in order to lay the foundation of treating the airway disorders with stenting in animal experiment. Methods: Multi-slice CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the longitudinal, transversal dimensions of the trachea, the glottis-carina length, the inner diameter and length of bronchi, and the angle formed by bronchial long axis and sagittal section were measured. Results: No significant difference was found in the inner diameters of various parts of the trachea and upper apical bronchi. The angle formed by bronchial long axis and sagittal section were smaller than that of the left ones. And the inner diameters of the right main bronchus was bigger than the left ones. Conclusion: The complex branching structure of the rabbit airway tree can be well displayed on spiral CT 3D images. Through measuring and statistical analysis of the results the authors have got a regressive equation for estimating the value of the inner diameter, length, angle, etc. concerning the airway tree, which is very helpful for providing the useful anatomical parameters in rabbit experiment. (authors)

  20. Lung studies with spiral CT. pitch 1 versus pitch 2

    International Nuclear Information System (INIS)

    Sartoni Galloni, S.; Miceli, M.; Lipparino, M.; Burzi, M.; Gigli, F.; Rossi, M.S.; Santoli, G.; Guidarelli, G.

    1999-01-01

    In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality [it

  1. Negative spiral CT in acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, T.; Olausson, A. [Karolinska Hospital, Stockholm (Sweden). Dept. of Thoracic Radiology; Johnsson, H. [Karolinska Hospital, Stockholm (Sweden). Dept. of Internal Medicine; Nyman, U. [County Hospital, Trelleborg (Sweden). Dept. of Radiology; Aspelin, P. [Huddinge Univ. Hospital (Sweden). Dept. of Radiology

    2002-09-01

    Purpose: To retrospectively evaluate the clinical outcome of non-anticoagulated patients with clinically suspected acute pulmonary embolism (PE) and no symptoms or signs of deep venous thrombosis (DVT) following a negative contrast medium-enhanced spiral CT of the pulmonary arteries (s-CTPA). Material and Methods: During a 24-month period, 739 of 751 patients underwent s-CTPA with acceptable diagnostic quality for clinically suspected acute PE. All patients who had a CT study not positive for PE were followed up with a questionnaire, a telephone interview and review of all medical reports, including autopsies and death certificates for any episodes of venous thromboembolism (VTE) during a 3-month period. Results: PE was diagnosed in 158 patients. Of the remaining 581 patients with a negative s-CTPA, 45 patients were lost to follow-up. 88 patients were excluded because of anticoagulation treatment (cardiac disorder n=32, chronic VTE or acute symptomatic DVT n=31, PE diagnosed at pulmonary angiography n=1, thrombus prophylaxis during diagnostic work-up or other reasons than VTE n=24) and 7 patients undergoing lower extremity venous studies because of symptoms of DVT (all negative). Thus, 441 patients with a negative s-CTPA and no DVT symptoms, venous studies or anticoagulant treatment constituted the follow-up cohort. Four of these patients had proven VTE (all PE) during the 3-month follow-up period. Two of the PE episodes contributed to the patient's death. Conclusion: Patients with clinically suspected acute PE, no symptoms or signs of DVT and a negative single slice s-CTPA using 3-5 mm collimation, may safely be left without anticoagulation treatment unless they are critically ill, have a limited cardiopulmonary reserve and/or if a high clinical suspicion remains.

  2. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  3. Spiral CT findings of inflammatory pseudotumor of the liver

    International Nuclear Information System (INIS)

    Lee, Ha Jong; Nam, Kyung Jin; Lee, Ki Nam; Park, Byeong Ho; Choi, Jong Cheol; Koo, Bong Sik; Nam, Ki Dong; Kim, Chan Seong

    1998-01-01

    To assess the spiral CT findings of inflammatory pseudotumor of the liver(IPTL), in order to distinguish this tumor from hepatocellular carcinoma, hepatic abscess or other space occupying liver lesions. The spiral CT findings of IPTL were retrospectively evaluated in six patients. All cases were confirmed by ultrasonography-guided gun biopsy. Four patients were men and two were women, and they were aged between 37 and 74 (mean, 49) years. The site, size, and number of IPTL were assessed, and their enhancement patterns were evaluated during the arterial, portal and delayed phases of spiral CT. Five cases involved a solitary mass and in one there were multiple masses with surrounding small nodules. Four cases occurred in the right lobe and two in the left lobe. Four of five surrounding nodules were in the left lobe. During the arterial phase of spiral CT scanning, three layers were separated from four of five cases of solitary mass;they were composed of central and peripheral portions of low attenuation, and an intermediate portion of isoattenuation. Delayed enhancement of the peripheral portion was prominent during the delayed phase. In the case involving multiple masses three layers were not seen during the arterial phase, but during the delayed phase enhancement was noted. The features of three layers, as seen on spiral CT, is considered to be very specific for distinguishing IPTL from other hepatic focal lesions.=20

  4. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  5. The potentials of spiral CT for detection of focal liver lesions; Moeglichkeiten der Spiral-CT zur Diagnostik fokaler Leberlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Helmberger, H. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kersting-Sommerhoff, B. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Lenz, M. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kirsten, R. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Bautz, W. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany)

    1996-03-01

    Spiral CT currently is the modality of choice for all aspects of diagnostic evaluation of the liver. Optimal selection of treatment should be based inter alia on the findings obtained by spiral CT with arterial application of contrast medium, as for example S-CTA (primary liver tumors), or S-CTAP (secondary liver tumors). Ultrasonography is the major supplementing modality. In the near future, MR imaging applying liver-specific contrast-enhancing agents is expected to become an important competing technique, and further developments of interest in diagnostic imaging of the liver are in the offing: it is not yet known which technique will be the modality of choice at the onset of the 21st century. (orig.) [Deutsch] Die Spiral-CT ist zur Zeit das empfehlenswerte Verfahren fuer alle Fragen der Leberdiagnostik. Zur optimalen praetherapeutischen Beurteilung der Leber sollte die Spiral-CT mit arterieller Kontrastmittelapplikation als S-CTA (primaere Lebertumoren) bzw. S-CTAP (sekundaere Lebertumoren) durchgefuehrt werden. Der US kommt ein Stellenwert als ergaenzende Methode zu. In Zukunft wird die MRT mit leberspezifischen Kontrastmitteln ein konkurrierendes Verfahren zur Spiral-CT darstellen, wobei eine weitere interessante Entwicklung auf dem Gebiet der hepatischen Bildgebung zu erwarten ist: Das diagnostische Verfahren der Wahl fuer die Leber zu Beginn des 21. Jahrhunderts ist noch nicht definiert. (orig.)

  6. Motion estimation and compensation in dynamic spiral CT reconstruction; Estimation et compensation de mouvement en reconstruction dynamique de tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St

    2004-07-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  7. Initial clinical experience with spiral CT angiography in the abdomen

    International Nuclear Information System (INIS)

    Gaa, J.; Stehling, M.K.; Costello, P.

    1993-01-01

    The latest developments in modern CT instruments, offering scanning times of a second, opened up new possibilities in CT imaging in combination with the spiral technique. The data set normally taken with single-breath-hold technique is free of respiratory artefacts and thus is a good basis for accurate 3D image reconstruction. Spiral CTA allows a non-invasive 3D imaging of various blood vessels. Patients with abdominal aortic aneurysms of aorto-iliac bypass can be examined as outpatients within 15 minutes. (orig.) [de

  8. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  9. Research on comparison of exposure with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode in coronary multi-slice spiral CT angiography

    International Nuclear Information System (INIS)

    Liu Bin; Guo Senlin; Wei Lan; Fei Xiaolu; Bai Mei

    2009-01-01

    Objective: The objective of this article was to compare patients dose with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode during coronary MSCT angiography. Methods: The research was based on phantom experiment and computer simulation to get the mean value of peak skin dose data and effective dose data respectively and to analyze deterministic and stochastic radiation risk. Results: The peak skin dose using ECG mode alone and using ECG and CAREDose 4D mode with the same image noise level was (87.4 ± 0.9) and (45.9 ± 1.2) mGy respectively. Effective dose was 17 and 10 rosy for ECG mode and ECG and CAREDose 4D mode respectively. Comparing with ECG mode alone, ECG and CAREDose 4D mode reduced organ dose of gonad, red marrow, lung, stomach, breast and thyroid by 40.0%, 36.7%, 39.3%, 37.7%, 38.8% and 38.9%, respectively. Conclusion: Results showed that ECG and CAREDose 4D mode can reduce radiation dose effectively comparing using ECG mode alone, and that ECG and CAREDose 4D mode should be widely applied clinically with appropriate initial settings. (authors)

  10. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  11. Value of noncontrast spiral CT for suspected acute appendicitis

    International Nuclear Information System (INIS)

    Choi, Pil Yeob; Lee, Sang Wook; Kwon, Jae Soo; Sung, Young Soon; Rho, Myoung Ho; Chang, Jeong A.

    1998-01-01

    To assess the diagnostic accuracy and clinical efficacy of noncontrast spiral CT in patients with suspected acute appendicitis. Over a six-month period, 100 patients with suspected acute appendicitis were prospectively evaluated with noncontrast spiral CT. All scans were obtained from the lower body of L3 to the symphysis pubis, with 5mm or 10mm collimation and pitch of 1 or 1.5, and without intravenous or oral contrast material. Diagnosis was established by means of surgical or clinical follow-up. Prospective diagnosis based on CT findings was compared with surgical results and clinical follow-up. Acute appendicitis was confirmed in 47 of 100 patients. On the basis of the Ct findings, SI patients were prospectively interpreted as positive for appendicitis, but in six the diagnosis was false-positive. Two of the 47 with acute appendicitis were prospectively interpreted as normal. The preoperative diagnosis of acute appendicitis was, thus, 45 true-positive, 47 true-negative, six false-positive and two false-negative yielding a sensitivity of 96%, a specificity of 89%, an accuracy of 92%, a positive predictive value of 88%, and a negative predictive value of 96%. Using CT, an alternative diagnosis was established in 14 patients. Noncontrast spiral CT is a useful technique for diagnosing acute appendicitis. =20

  12. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  13. Floating venous thrombi: diagnosis with spiral-CT-venography; Diagnose flottierender venoeser Thromben mittels Phlebo-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Gartenschlaeger, M. [Mainz Univ. (Germany). Klinik fuer Radiologie; Klose, K.J. [Univ. Marburg, Medizinisches Zentrum fuer Innere Medizin, Abt. Poliklinik (Germany); Schmidt, J.A. [Univ. Marburg, Medizinisches Zentrum fuer Radiologie, Abt. fuer Strahlendiagnostik (Germany)

    1996-05-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [Deutsch] Mittels lokaler Kontrastmittelapplikation in eine ipsilaterale Fussrueckenvene und Spiral-CT wurden 16 konsekutive Faelle konventionell phlebographisch gesicherter Phlebothrombose untersucht, zusaetzlich wurde die farbkodierte Doppler-Ultraschalluntersuchung durchgefuehrt. In der konventionellen Phlebographie waren 8/16 Thromben flottierend, die uebrigen 8/16 wandadhaerent. In der Spiral-CT zeigten sich Wandadhaerenzen in 15/16 Faellen; der nachgewiesene flottierende Thrombus stimmte mit der konventionellen Phlebographie ueberein. Im farbkodierten Doppler-Ultraschall erschienen die Thromben in 3/16 Faellen flottierend, darunter ein von der konventionellen Phlebographie abweichender Befund. Der Vergleich von konventioneller und CT-Phlebographie ergab eine komplette Uebereinstimmung fuer konventionell phlebographisch nachgewiesene Wandadhaerenz und eine signifikante Abweichung

  14. The role of spiral CT in pelvic trauma management

    International Nuclear Information System (INIS)

    Cheung, E.C.F.; Fung, K.K.L.

    1999-01-01

    Rapid and accurate assessment of pelvic injury is critical for good patient management. Plain X-ray is often used as a preliminary evaluation of the injury but this may not give adequate diagnosis of the acetabulum fracture, subtle fracture of the pelvic bone and the associated soft tissue injuries. Nowadays, spiral CT has taken an increasing role in the evaluation of pelvic trauma. It gives a rapid assessment of the bone and soft tissue injuries as compared to conventional CT. Besides, 2-D (multiplanar imaging) and 3-D image reconstruction with multiple angle views, provide the maximum information which facilitates detailed pelvic trauma evaluation. Three cases were used to illustrate the role of spiral CT in pelvic trauma management. Copyright (1999) Blackwell Science Pty Ltd

  15. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  16. Accuracy and reliability of thyroid volumetry using spiral CT and thyroid volume in a healthy, non-iodine-deficient Chinese adult population

    Energy Technology Data Exchange (ETDEWEB)

    Shu Jian, E-mail: shujiannc@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Zhao Jiannong, E-mail: zhaojiannong@tom.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Guo Dajing, E-mail: guodaj@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Luo Yindeng, E-mail: yindengluo_1019@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Zhong Weijia, E-mail: zhongweijia2003@eyou.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Xie Weibo, E-mail: radiologycq@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China)

    2011-02-15

    Objective: The purpose of this study was to assess the accuracy and reliability of thyroid volumetry using spiral CT and to investigate thyroid volumes for a healthy, non-iodine-deficient adult population in southwestern region of China. Materials and methods: Spiral CT was performed in phantoms and adult subjects with normal thyroid, and the volumes were measured by observers with 5 years or more of CT experience. The phantom volumes and the thyroid volumes of all subjects were noted. Results: For the thyroid phantoms, there was no significant difference between the true and CT calculated volumes (t = 0.862, P = 0.399), and the correlation was excellent (ICC = 0.9995, P = 0.000). In the subjects for reliability analysis, the intraobserver or interobserver differences for CT volumetric measurement of thyroid were not significant (P > 0.05). The intraobserver or interobserver correlations were very high (ICC > 0.99, P < 0.001). In the subjects for population analysis, the median of the thyroid volumes was 11.45 cm{sup 3}. The nonparametric Mann-Whitney U-test showed no significant difference for the thyroid volume between sexes (U = 4388.00, Z = -1.118, P = 0.264). The nonparametric Kruskall-Wallis test showed no significant difference in all age groups ({chi}{sup 2} = 13.466, P = 0.062). There was a slight negative correlation between the thyroid volume and age (r{sub s} = -0.166, P = 0.019). Conclusion: The accuracy and reliability of multi-slice spiral CT in measuring thyroid volume are very high. The thyroid volumes are not significantly difference between genders or among decades for the healthy, non-iodine-deficient adult population in southwestern region of China.

  17. Spiral CT pneumocolon: applications, status and limitations

    International Nuclear Information System (INIS)

    Harvey, C.J.; Renfrew, I.; Taylor, S.; Gillams, A.R.; Lees, W.R.

    2001-01-01

    CT pneumocolon is a promising new technique in the diagnosis and management of colon pathology. CT pneumocolon can detect (sensitivity >95%) and stage (accuracy 79%) colorectal cancer and is very accurate in the differentiation of malignant from benign colonic pathologies. It has excellent detection rates for polyps >10 mm in diameter. Several studies using 3D virtual colonoscopy have already proven its high sensitivity and specificity in polyp detection making this technique robust as a screening tool. The combined results for virtual colonoscopy, from all centres, show a sensitivity of >85% in the detection of polyps 10 mm or greater in size, 70-80% for 5-9 mm polyps and an overall specificity of 90%. CT pneumocolon is a safe, non-invasive and cost-effective method for detecting colonic carcinomas and adenomas and correctly identifying which patients need further colonoscopy. The technique is quick, well tolerated and non-operator dependent. It can also image the proximal colon when distal stenoses prevent endoscopic and barium examination. CT pneumocolon is able to identify the features and complications of inflammatory bowel disease. Further research is warranted to fully assess its impact in terms of a screening tool, acceptability, availability and cost benefit. (orig.)

  18. Comparative analysis between spiral CT and pathology of pulmonary nodules

    International Nuclear Information System (INIS)

    Wang Kaifu; Zhang Zhanqing

    2007-01-01

    Objective: To explore the value of spiral CT in the diagnosis of atypical pulmonary nodules. Methods: CT, clinic and histopathologic data of 72 patients with atypical pulmonary nodules confirmed by surgical resection in 41 cases and/or biopsy in 31 cases were retrospectively analyzed. Results: CT scans demonstrated slight lobulation in 34 cases, irregular margin in 50 cases, long speculate in 10 cases, air-bronchogram in 2 case, vacuole in 2 case. 38 pulmonary cancer, 22 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were diagnosed with spiral CT. However, 30 pulmonary cancer, 30 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were confirmed by histopathology. The overall accurate diagnostic rate of pulmonary cancer was 66.7% (20/30), pulmonary tuberculosis was 60%(18/30), pulmonary inflammatory pseudotumors was 16.7%(2/12). 40 cases were diagnosed correctly and 32 cases were misdiagnosed with CT in 72 cases of atypical pulmonary nodules. The misdiagnostic rate of CT was 44.4%. 10 cases of lung cancer were misdiagnosed, including 4 cases of tuberculosis (long speculate or irregular margin) and 6 cases of inflammatory pseudotumors (irregular margin or long speculate or air-bronchogram). 12 cases of tuberculosis were misdiagnosed, including 8 cases lung cancer (slight lobulation) and 4 cases of inflammatory pseudotumors (slight lobulation). 10 cases inflammatory pseudotumor were misdiagnosed as lung cancer (slight lobulation). Conclusion: Spiral CT was very useful in the localization and morphological describing, but difficult in qualitative diagnosing of atypical pulmonary nodules, exactly diagnosis was relied on surgery and biopsy. (authors)

  19. Pulmonary sequestration: diagnosis with three dimensional reconstruction using spiral CT

    International Nuclear Information System (INIS)

    Nie Yongkang; Zhao Shaohong; Cai Zulong; Yang Li; Zhao Hong; Zhang Ailian; Huang Hui

    2003-01-01

    Objective: To evaluate the role of three dimensional (3D) reconstruction using spiral CT in the diagnosis of pulmonary sequestration. Methods: Ten patients with pulmonary sequestration were analyzed. The diagnoses were confirmed by angiography in 2 patients, by operation in 2 patients, and by CT angiography in 6 patients. All patients were examined with Philips SR 7000 or GE Lightspeed Plus scanner. CT images were transferred to a workstation and 3D reconstruction was performed. All images were reviewed and analyzed by two radiologists. Results: Among 10 patients, the pulmonary sequestration was in the right lower lobe in 1 patient and in the left lower lobe in 9 patients. Anomalous systemic arteries originated from thoracic aorta in 8 patients and from celiac artery in 2 patients. On plain CT scan, there were 4 patients with patchy opacities, 3 patients with hilar mass accompanying vascular engorgement and profusion in adjacent parenchyma, 2 patients with finger-like appendage surrounded by hyper-inflated lung, and 1 patient with lung mass-like lesion. Enhanced CT revealed anomalous systemic arteries in 9 patients and drainage vein in 7 patients. Maximum intensity projection (MIP) and curvilinear reconstruction could depict the abnormal systemic artery and drainage vein in sequestration. Surface shadow display (SSD) and volume rendering (VR) could delineate the anomalous systemic artery. Conclusion: 3D reconstruction with enhanced spiral CT can depict anomalous systemic artery and drainage vein and it is the first method of choice in diagnosing pulmonary sequestration

  20. Multidetector spiral CT arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E. [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)], E-mail: frederic.lecouvet@uclouvain.be; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)

    2008-10-15

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  1. Multidetector spiral CT arthrography of the shoulder

    International Nuclear Information System (INIS)

    Lecouvet, Frederic E.; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile

    2008-01-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings

  2. Design of wireless data transmission system for spiral CT

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Liu Huaili

    2010-01-01

    A new wireless data transmission scheme based on UWB was proposed after studying the structure and character of spiral CT transmission system, the system was designed and validated. Using UWB device as wireless module to realize wireless data transmission. Using FPGA as main controller to meet the requirement of timing control for system module. Using two pieces of SDRAM in pingpang operation to realize large capacity storage mechanism. Using USB 2.0 interface to realize high-speed connection with UWB module. The results show that the transmission speed of the system arrival at 16.87 M bit ps within 3 meters, and the precision is 100%, it can be used for line-array spiral CT. (authors)

  3. Three-dimensional spiral CT for neurosurgical planning.

    Science.gov (United States)

    Klein, H M; Bertalanffy, H; Mayfrank, L; Thron, A; Günther, R W; Gilsbach, J M

    1994-08-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important.

  4. Floating venous thrombi: diagnosis with spiral-CT-venography

    International Nuclear Information System (INIS)

    Gartenschlaeger, M.; Schmidt, J.A.

    1996-01-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [de

  5. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P. [Dept. of Radiology, St. Luc University Hospital, Brussels (Belgium)

    2001-11-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  6. Three-dimensional spiral CT for neurosurgical planning

    International Nuclear Information System (INIS)

    Klein, H.M.; Bertalanffy, H.; Mayfrank, L.; Thron, A.; Guenther, R.W.; Gilsbach, J.M.

    1994-01-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important. (orig.)

  7. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    International Nuclear Information System (INIS)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P.

    2001-01-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  8. Abdominal wall hernias: imaging with spiral CT

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G.

    2000-01-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  9. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  10. Virtual gastroscopy using spiral CT in gastric lesions

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Kang, Heoung Keun; Jeong, Yong Yeon; Yoon, Man Won; Song, Sang Gook; Jeong, Gwang Woo

    1998-01-01

    To compare virtual gastroscopy using spiral CT with conventional endoscopy for the detection and evaluation of gastric lesions. During a previous six-month period, 30 patients with pathologically-proven gastric lesions underwent conventional endoscopy and virtual gastroscopy using spiral CT. There were 18 cases of advanced gastric carcinoma, eight benign ulcers, and four submucosal tumors(two leiomyomas, two lymphomas). Source images of virtual gastroscopy were three-dim-ensionally reconstructed within an Advantage Windows Workstation and virtual gastroscopic images were obtained using Navigator Software. On analysis, images were graded according to their quality(excellent, good, poor). Virtual gastroscopic images were interpreted by two radiologists blinded to conventional endoscopic findings, and were subsequently compared with endoscopic findings in terms of detectability and findings. In the cases of advanced gastric carcinoma, lesions were classified according to Borrmann's system. For virtual gastroscopy, overall image quality was excellent in 21 cases(70%), good in five(17%), and poor in four(13%). Lesions were detected in 25 cases(83%). Among the 18 advanced gastric carcinomas, virtual gastroscopy image quality was excellent in 14 cases(78%), good in two(11%), and poor in two(11%). Lesions were detected in 16 cases(89%). Two Borrmann type IV cases were not detected. Among the eight benign ulcers, virtual gastroscopy image quality was excellent in three cases(38%), good in three(38%), and poor in two(25%). The detection of lesion was possible in five cases(63%). In all submucosal tumors, virtual gastroscopy image quality was excellent. Lesions were detected in all cases. Virtual gastroscopy using spiral CT is safe and noninvasive, and for the evaluation of gastric lesions may be complementary to axial CT. It successfully detects gastric lesions, and in depicting the pattern of gastric folds its image quality is excellent.=20

  11. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  12. Three-dimensional spiral CT of craniofacial malformations in children

    International Nuclear Information System (INIS)

    Binaghi, S.; Gudinchet, F.

    2000-01-01

    Objective. To assess the value of three-dimensional CT (3D CT) in the diagnosis and management of suspected paediatric craniofacial malformations. Materials and methods. Twenty-eight children (12 girls, 16 boys) with a mean age of 4 years, suffering from craniofacial or cervical malformations, underwent craniofacial spiral CT. 3D reformatting was performed using an independent workstation. Results. 3D CT allowed the preoperative evaluation of 16 patients with craniosynostosis and the post-surgical management of 2 patients. 3D CT clearly depicted malformations of the skull base involving the petrous bone in seven patients (four cases of Goldenhar-Gorlin syndrome, one case of Treacher-Collins syndrome and two cases of Crouzon's disease). Four patients with craniofacial clefts were also evaluated. Radiological findings were confirmed by the clinical and intraoperative findings in all patients that underwent surgical treatment. Movement artefacts and ''Lego effect'' related to abrupt change of cranial vault border were encountered and are discussed. Conclusions. 3D CT of the skull can safely and reliably identify paediatric craniofacial malformations involving bone, and it should be used as morphological mapping to help the surgeon in planning surgical treatment. (orig.)

  13. Abdominal spiral CT in children: which radiation exposure is required?

    Energy Technology Data Exchange (ETDEWEB)

    Wormanns, D.; Diederich, S.; Lenzen, H.; Ludwig, K.; Papke, Karsten; Hagedorn, Claudia; Heindel, Walter [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Lange, P.; Link, T.M. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Dept. of Radiology, Technical Univ. Muenchen (Germany)

    2001-11-01

    We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: group A with reduced radiation exposure (tube current 50 mA, CT dose index CTDI{sub FDA} {<=}0.83 mGy) and group B with standard radiation exposure (tube current {>=}100 mA, CTDI{sub FDA} {>=}1.66 mGy). Image quality was assessed using a four-part scale ('excellent', 'good', 'sufficient', 'poor') on visual image impression and visibility of 32 anatomical details. Five experienced radiologists read the CT scans independently who were blinded to the examination parameters. Differences in ranked data were evaluated with Wilcoxon's rank sum test. No difference between groups A and B was observed in visual image impression. Detail visibility was significantly lower in group A, but the differences were limited to right upper quadrant structures (portal vein, common bile duct, pancreatic head, adrenals) and to arterial branches. Significant differences in visibility rated as 'poor' were only found for the hepatic, splenic and renal arteries; all other structures showed no difference between groups A and B. A protocol with reduced radiation exposure (50 mA, CTDI{sub FDA} {<=}0.83 mGy) allowed the demonstration of most anatomic structures in abdominal spiral CT in young children. For the precise demonstration of small details (e.g. structures of the right upper quadrant), a protocol with standard radiation exposure ({>=}100 mAs) was superior. (orig.)

  14. Historical review on the development of computed tomography on the occasion of putting a new spiral CT into operation at the University of Veterinary Medicine, Vienna

    International Nuclear Information System (INIS)

    Henninger, W.

    2002-01-01

    Linear tomography has been well known since the thirties of the last century. Before and alter World War II attempts of taking cross sections were done radiographically, but image quality was extremely poor. About 1960 A.M. Cormack developed a possibility to measure body densities for radiation therapy. After having attempted digitization of x-ray intensities during tissue penetration, G.N. Hounsfield constructed the first scanner in 1972 - in the first run only to examine the head. Improvements of technology lead to a series of generations of scanners which ended in the development of spiral CT and multi-slice detectors. In veterinary medicine the first papers on the use of CT in small animals were published by clinicians in the United States and in Germany nearly at the same time in 1980. A number of reports appeared afterwards from clinicians worldwide. The technique for examination of the horse was first described in the United States in 1986; in Europe the first CT scanner examining horses was established in Utrecht. At the Radiology Clinic of the University of Veterinary Medicine, Vienna, the first scanner for clinical use started to operate in summer 1993. The diagnostic possibilities improved in 1997 by introduction of a large animal weight bearing table. A new spiral CT has been put into operation in February 2001. CT has dramatically improved diagnostic accuracy in diagnostic imaging and lead to advanced therapy and prognosis for the patient in many specialist fields of veterinary medicine, e.g. neurosurgery, neurology, oncology, or orthopedics. (author)

  15. Borrmann type IV adenocarcinoma versus gastric lymphoma : spiral CT evaluation

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Kim, Yun Hwan; Shin, Kue Hee; Hong, Suk Joo; Kim, Hong Weon; Park, Cheol Min; Chung, Kyoo Byung; Cho, Hyun Deuk

    1999-01-01

    To distinguish the spiral CT findings of Borrmann type IV adenocarcinoma from those of gastric lymphoma with diffuse gastric wall thickening. We retrospectively reviewed the spiral CT scans of 30 patients with Borrmann type IV adenocarcinoma and nine with gastric lymphoma with diffuse gastric wall thickening. In all patients the respective condition was pathologically confirmed by gastrectomy. CT scanning was performed after peroral administration of 500-700ml of water. A total of 120-140 ml bolus of nonionic contrast material was administered intravenously at a flow rate of 3 ml/sec and two-phase images were obtained at 35-45 sec(early phase) and 180 sec(delayed phase) after the start of bolus injection. Spiral CT was performed with 10mm collimation, 10mm/sec table feed and 10mm reconstruction. We evaluated the degree and homogeneity of enhancement of thickened entire gastric wall, and the enhancement pattern of gastric inner layer, as seen on early-phase CT scans. On early and delayed views, the thickness of gastric wall and the presence of perigastric fat infiltration were determined. The enhancement patterns of gastric inner layer were classified as either continuous or discontinuous thick enhancement, thin enhancement, or nonenhancement. The thickness of gastric wall was 1.2-3.5cm(mean 2.2cm) in cases of adenocarcinoma and 1.2-7.6cm(mean 4cm) in lymphoma. Perigastric fat infiltration was seen in 24 patients with adenocarcinoma(80%) and four with lymphoma(44%). In those with adenocarcinoma, the degree of enhancement of entire gastric wall was hyperdense in fifteen patients(50%) and isointense in eleven (37%). Seven patients with lymphoma(78%)showed hypodensity. In those with adenocarcinoma, continuous thick enhancement of gastric inner layer was seen in 18 patients(60%) and discontinuous thick enhancement in nine(30%). In lymphoma cases, no thick enhancement was observed. Thin enhancement of gastric inner layer was demonstrated in three patients with

  16. Pulmonary embolism: spiral CT evaluation; Embolie pulmonaire: apport de la tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Senac, J.P.; Vernhet, H.; Bousquet, C.; Giron, J.; Pieuchot, P.; Durand, G.; Benezet, O.; Aubas, P. [Centre Hospitalier Universitaire, 34 - Montpellier (France)

    1995-06-01

    Purpose: Spiral computed tomography was compared retrospectively with digital substraction pulmonary angiography (PA) in 45 patients suspected of having acute or chronic pulmonary embolism. Materials and method : 45 patients in whom the presence of acute or chronic pulmonary embolism was suspected underwent examination by spiral CT and PA. Diagnosis of pulmonary embolism was based on the direct visualization of intraluminal clots. The study of the agreement between the two methods was based on the Kappa test. In 35 cases, pulmonary emboli were proved. Acute pulmonary emboli were present in 28 cases and chronic in 7 cases. Results: Spiral computed tomography represents an excellent way to detect acute pulmonary embolism. In the chronic form, spiral CT is better than PA to detect intraluminal clots. However, Spiral CT can fail to detect small emboli in the peripheral arterial bed. In the 10 patients without pulmonary embolism, the spiral CT proved diagnosis pulmonary oedema (n=3), lymphangi-carcinoma (n=4), pleural effusion (n=3). Conclusion: This study suggest that the spiral CT examination is accurate for diagnosis of pulmonary embolism specifically in case of suspected important embolism. The advantages of spiral CT are multiple (non invasive, wide diagnosis spectrum). However, may be a limitation to is use is insufficient distal thrombi detection. This eventuality (5 to 10% in the Pioped study) justify the practice of pulmonary angiography. Spiral CT improvements should reduce this insufficiency in the next future. (Authors). 16 refs., 4 figs., 3 tabs.

  17. Clinical application of low-dose spiral CT for orthodontics

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Shu Huang; Lin FeiFei; Li Zhiyong; Sun Jie

    2009-01-01

    Objective: To determine the effect of reducing the value of mA or kV on the image quality and the radiation dose of the patients undergoing low-dose spiral CT for orthodontics. Methods: Thirty patients were divided into three groups, each group has 10 patients. They were group 1 (80 kV and 200 mA), group 2 (120 kV and 80 mA), group 3 (120 kV and 200 mA) The volume CT dose index (CTDI) was recorded and the average dose-length produce (DLP) was calculated in three groups,respectively. Image quality of three groups were compared and scored by two radiologists, and the results were statistically analysed. Results: The CTDI and DLP of 80 kV group (group 2) were 8.7 mGy and (36.80 ± 3.60) mGy · cm, respectively, those of 80 mA group (group 3) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively, and those of conventional-dose group (group 1) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively. There was no significant difference among three groups in diagnostic image quality. Conclusions: Low-dose spiral CT for orthodontics, especially the low-kV scan, may decrease the radiation exposure and guarantee the image quality. (authors)

  18. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  19. Three phase dynamic CT with double spiral CT: utility of determination of stomach cancer stage

    International Nuclear Information System (INIS)

    Jung, Min Ha; Kim, Hong In; Kim, Tae Hyung; Lee, Ki Yeol; Cho, June Il; Park, Cheol Min; Cha, In Ho

    1997-01-01

    To evaluate the utility of three phases of spiral CT in the diagnosis of stomach cancer. Between August 1994 and March 1995, thirty eight patients with stomach cancer, demonstrated on spiral CT, underwent surgery. Twenty-eight cases were advanced and ten were early. There were 27 men, and 11 women, and their average age was 52.8 years old (33-77). After ingestion of 600-700ml of water, 120-140ml of nonionic contrast material was injected intravenously. Spiral CT scanning was performed in 10mm slice thickness and of 10mm/sec table speed. Three phase image were obtained at 25sec (arterial phase), 60-65sec (venous phase) and 4min (equilibrium phase) after the start of bolus injection. On each phase, CT findings were compared with pathologic results, and tumor detectibility, depth of tumor invasion and lymph node metastasis was analysed. Thirty of the 38 carcinomas (79%) were detected on the arterial phase, 33 (81%) on the venous phase and 30 (79%) on the equilibrium phase. Depth of tumor invasion was measured accurately in 27 of 38 cases (71%) : T1-4/10 (40%), T2-8/11 (73%), T3-13/15 (87%), T4-2/2 (100%). We overstaged one case of T1 as T2 and two cases of T2 as T3, and understaged one case of T2 as T1 and two cases of T3 as T2. Among the 16 enlarged lymph nodes larger than 8mm, 13 cases were positive on pathologic examination and the sensitivity was 65%. With three-phase spiral CT scanning, we obtained 71% accuracy of depth of tumor invasion. The venous phase is most useful for tumor detection and for determining depth of tumor invasion and lymph node metastasis

  20. Hypoxic-ischemic encephalopathy in neonates and infants: an evaluation with spiral CT

    International Nuclear Information System (INIS)

    Zhu Linghua

    2006-01-01

    Objective: To evaluate spiral CT imaging in the diagnosis of hypoxic-ischemic encephalopathy (HIE) in the neonates and infants. Methods: 112 children with history of asphyxia in peri-natal period and evident clinical symptoms were evaluated with Spiral CT. CT findings were studied. Results: 46 minor cases, 57 moderate cases and 9 severe cases were found out of 112 patients. Intracranial hemorrhage was revealed in 38 cases. Mortality occurred in 1 case. Conclusion: Spiral CT is helpful for evaluating brain damage and predicting prognosis in neonates with HIE. (authors)

  1. Cerebral av angiomas: 3-dimensional demonstration by spiral CT

    International Nuclear Information System (INIS)

    Rieger, J.; Hosten, N.; Neumann, K.; Lemke, A.J.; Langer, R.; Lanksch, W.R.; Pfeifer, K.J.; Felix, R.

    1994-01-01

    In 20 patients with known or suspected supratentorial arteriovenous malformations, an attempt was made to see how far CT angiography with 3-dimensional reconstructions is able to make a diagnosis and to differentiate the various components of the angioma. Spiral CT was performed following an intravenous bolus injection of 60-80 ml of iodine containing contrast medium. In all patients the diagnosis was confirmed by intra-arterial DSA of the vertebral vessels. In 13 patients, av malformations could be diagnosed following multiplanar 3-D reconstructions which agreed with the findings on DSA. The large supplying vessels, the nidus and the large draining veins could be defined with certainty. In 6 patients follow-up examination after embolisation was performed. The results could be demonstrated in three dimensions and the success of treatment could be documented unequivocally. CT angiography with 3-D reconstruction is able to supply important information in the majority of intracranial av malformations, both during initial investigation and following treatment. (orig.) [de

  2. Spiral CT: An innovative method of volumetric recording. Pt. 1

    International Nuclear Information System (INIS)

    Kalender, W.A.; Vock, P.; Polacin, A.; Soucek, M.

    1990-01-01

    A major advance in the field of CT diagnosis has been made with the development of spiral computed tomography. It permits a complete photographic recording of volumes in such a way that even 'minor' pathological changes can be detected and reconstructed providing the absence of respiration-induced organ displacement. During one session, in which up to 24 360deg scans may be obtained within 24 seconds, the patient is continuously shifted at a speed of 10 mm/s, which permits the volumes recorded to be increased up to a height of 24 cm. The underlying methodology is described, as is the procedure to be used in the reconstruction of planar pictures from the volumes recorded. (orig./GDG) [de

  3. Induced pneumoperitoneum in spiral CT evaluation of gastric cancer

    International Nuclear Information System (INIS)

    Guo Hua; Gao Jianbo; Li Yintai; Yang Xuehua; Chen Xuejun; Guan Sheng

    2001-01-01

    Objective: To evaluate the diagnostic value and clinical significance of preoperative staging in gastric cancer with induced pneumoperitoneum in spiral CT (SCTPP). Methods: Both routine SCT and SCTPP were performed in 52 lean patients suffered from gastric cancers, and comparison was made between SCT findings and surgical and histopathologic findings. Results: The accuracy of routine SCT and SCTPP in determining the T-staging was 72% and 96%, respectively (x 2 = 8.0, P 2 = 0.006, P > 0.05). The sensitivity in determining M-staging was 61% and 100%, respectively (x 2 = 0.04, P 2 6.03, P < 0.05). Conclusion: The accuracy of SCTPP in determining preoperative staging of gastric cancer was significantly higher than that of routine SCT. SCTPP has important guiding significance for the selection of the treatment strategy in gastric cancer

  4. Spiral CT portography: correlation with different injection rate

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Chen Zuwang; Chen Gang; Chen Jin; Chen Huiming

    2000-01-01

    Objective: To choose optimal injection rate in spiral CT portography(CTP) by comparing 3D CTP images using different injection rates. Methods: Thirty-seven patients were randomly divided into 2 groups (11 and 26 cases in each group). Single-level dynamic scan was completed at the first liver hilus, starting at 15s or 30s after initial contrast injection(2 ml/kg) with injection rate 1.5 ml/s (slow group) or 3.0 ml/s (rapid group). The continuous scan were repeated every 5s for 120s or 135s. ROI was used to measure the CT value of the portal vein and the liver parenchyma, respectively, and then the time-density curves were drawn. Spiral CT portography were performed at injection rate of 1.5 ml/s or 3.0 ml/s as the delay time designed described above, including 98 cases in rapid group and 12 cases in slow group. Both MPVR (multi-projection volume reconstruction) and MIP (maximum intensity projection) were employed for reconstruction. All images were ranked according to the grade of portal vein, the different CT value between the portal vein and the liver parenchyma, the edge's definition of blood vessel, the grade of hepatic vein and the display of IVC by 2 radiologists. Results: The maximum density difference in average between the portal vein and the liver parenchyma was 53.4 HU and 83.9 HU, respectively (t = 16.418, P < 0.001) in slow group and rapid one, and the mean reaching time was 80s and 60s, respectively (t = 13.394, P < 0.001). In slow injection group, the average score of MPVR image was 9.3, while it was 12.5 (t = 3.514, P < 0.01) in rapid injection group. Rapid group was better than slow one at the PV-L, the grade of the portal vein, and the edge's definition of blood vessel. Conclusion: Using rapid injection rate (3.0 ml/s), the maximum density difference between the portal vein and the liver parenchyma increases, and the mean reaching time shortens. The quality of 3D CTP image of rapid injection rate (3.0 ml/s) is superior to that of slow injection rate

  5. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  6. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  7. Patient doses from CT examinations in the United Arab Emirates

    International Nuclear Information System (INIS)

    Janeczek, J.

    2006-01-01

    Full text of publication follows: The main goal of the study was to estimate effective patient doses from the 6 most common CT examinations for different types of CT scanners within the United Arab Emirates. The results were used to assess future trends in patient CT doses following rapid replacement of axial and single-slice spiral scanners by multi-slice scanners. At present all three types of scanner technology exist: axial, spiral and multi-slice with axial scanners being gradually replaced by multi-slice scanners as the medical infrastructure of the country is modernized. Altogether there are more than 30 CT scanners in the country with a population of 4 million. Out of these 11 scanners are 16-slice models with tube-current modulation system. The majority of larger United Arab Emirates hospitals have at least two CT scanners: a single slice and 4 or 16-slice scanner. The survey was carried out with data collection forms distributed to the majority of CT scanner users in the United Arab Emirates hospitals, both private and government. Effective doses for different examinations were calculated from T.L.D. measurements using an Alderson Rando phantom simulating an average size patient. Our results show that effective doses to patients initially increased with the introduction of 4-slice scanners. Multi-slice scanners with 16 and more slices have tube-current modulation system as a standard. It is routinely used by radiographers in almost all examinations resulting in patient dose reduction up to 40 % in certain examinations. Another factor affecting population dose is the increased number of patients examined using multi-slice scanners. In the United Arab Emirates there was an increase of more than 30 % in the annual number of patients examined using multi-slice scanners in comparison to single-slice scanners. This fact is attributed to the ease and speed of operation of multi-slice scanners. Rapid increase in number of CT examinations is of concern. Medical

  8. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  9. Improvement in printing technique of spiral CT three-dimensional colour image

    International Nuclear Information System (INIS)

    Wang Yicheng; Liu Feng; Zhang Ling

    2005-01-01

    Objective: To investigate the printing technique of spiral CT three-dimensional (3D) colour image. Methods: The 3D colour images of 136 patients were printed, with the equipment of Marconi spiral CT, personnel computer, colour ink printer, and network switchboard. Results: All printed images were satisfied by this method. Conclusion: This technique is economic, simple, and useful, and can meet the need for clinical diagnosis and operation. (authors)

  10. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  11. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  12. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  13. Colorectal carcinoma: preoperative staging with water enema spiral CT

    International Nuclear Information System (INIS)

    Guan Sheng; Gao Jianbo; Li Yintai; Chen Xuejun; Yang Xuehua; Yang Xiaopeng; Cheng Jingliang

    2001-01-01

    Objective: To determine the value and limitation of water enema spiral CT (WESCT) in staging of colorectal carcinoma. Methods: Forty-eight patients with histologically proven rectum or colon carcinoma were included in this study. All of them were examined by SCT, and the preoperative staging of TNM and Duke were used based on the findings of SCT. The results of WESCT were compared with those of surgical and pathological examination in all cases. Results: All lesions in the 47 cases were demonstrated clearly by WESCT and the sensitivity was 97.9%; 39 cases of 48 patients were correctly staged with TNM and 42 cases with Duke, the accuracy was 81.3% and 87.5% respectively, which were higher than the overall 50 % accuracy reported by references; (3) The accuracy of WESCT was 89.6% (43/48) in T stage and 81.3% (39/48) in N stage. Three cases in M stage were all diagnosed correctly; Conclusion: WESCT scan is a better method of depicting the colorectal carcinoma. It allows for accurate depiction and staging of colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. It is the best imaging method for staging the colorectal carcinoma . However the value of WESCT for early T staging in colorectal carcinoma and minute metastasis of lymph nodes or liver is limited

  14. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  15. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  16. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  17. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  18. The role of spiral CT in patients with intermediate probability V/Q scans: can spiral CT replace pulmonary angiography?

    International Nuclear Information System (INIS)

    Vu, T.; Glenn, D.; Lovett, I.; Moses, J.; Wadhwa, S.S.; Nour, R.

    2000-01-01

    Full text: Spiral CT (SCT) has been advocated as a replacement for pulmonary angiography (PA)in patients with intermediate probability (IP) ventilation-perfusion lung scans (V/Q). More generally it has been proposed as a replacement for V/Q to detect Pulmonary Embolism. This study investigates the accuracy of SCT in the IP patient group 31 patients with IP scans (Modified PIOPED criteria) who were not at high risk of contrast nephrotoxicity were enrolled to have both SCT and PA within the 24 hours following their V/Q. Patients were classified as IP due to a single segmental mismatch (n=7) or a matched V/Q abnormality corresponding to CXR opacity (n=21), or both (n=3). PA is the gold standard for the detection of PE. SCT was read by an experienced radiologist blinded to the PA results. SCT was performed according to standard protocol. All SCT were technically satisfactory for interpretation. Pulmonary embolism was present in 9/31 patients (29%). Of the patients with PE detected by PA, SCT was positive in 4 (44% sensitivity). Of the 22 patients who did not have PE, SCT was negative in 21 and positive in one (96% specificity). In conclusion SCT has limited sensitivity for the detection of PE in patients with IP lung scans. SCT may not be an adequate replacement for PA. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  20. Measurement error of spiral CT volumetry: influence of low dose CT technique

    International Nuclear Information System (INIS)

    Chung, Myung Jin; Cho, Jae Min; Lee, Tae Gyu; Cho, Sung Bum; Kim, Seog Joon; Baik, Sang Hyun

    2004-01-01

    To examine the possible measurement errors of lung nodule volumetry at the various scan parameters by using a small nodule phantom. We obtained images of a nodule phantom using a spiral CT scanner. The nodule phantom was made of paraffin and urethane and its real volume was known. For the CT scanning experiments, we used three different values for both the pitch of the table feed, i.e. 1:1, 1:15 and 1:2, and the tube current, i.e. 40 mA, 80 mA and 120 mA. All of the images acquired through CT scanning were reconstructed three dimensionally and measured with volumetry software. We tested the correlation between the true volume and the measured volume for each set of parameters using linear regression analysis. For the pitches of table feed of 1:1, 1:1.5 and 1:2, the mean relative errors were 23.3%, 22.8% and 22.6%, respectively. There were perfect correlations among the three sets of measurements (Pearson's coefficient = 1.000, p< 0.001). For the tube currents of 40 mA, 80 mA and 120 mA, the mean relative errors were 22.6%, 22.6% and 22.9%, respectively. There were perfect correlations among them (Pearson's coefficient=1.000, p<0.001). In the measurement of the volume of the lung nodule using spiral CT, the measurement error was not increased in spite of the tube current being decreased or the pitch of table feed being increased

  1. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  2. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  3. Spiral CT scanning plan to generate accurate Fe models of the human femur

    International Nuclear Information System (INIS)

    Zannoni, C.; Testi, D.; Capello, A.

    1999-01-01

    In spiral computed tomography (CT), source rotation, patient translation, and data acquisition are continuously conducted. Settings of the detector collimation and the table increment affect the image quality in terms of spatial and contrast resolution. This study assessed and measured the efficacy of spiral CT in those applications where the accurate reconstruction of bone morphology is critical: custom made prosthesis design or three dimensional modelling of the mechanical behaviour of long bones. Results show that conventional CT grants the highest accuracy. Spiral CT with D=5 mm and P=1,5 in the regions where the morphology is more regular, slightly degrades the image quality but allows to acquire at comparable cost an higher number of images increasing the longitudinal resolution of the acquired data set. (author)

  4. The value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Huang Zhi; Liu Zhang; Yang Chaoxiang; Lin Chengye; Zhang Li; Li Yuxiang; Ma Yunyan; Xiao Haisong; Lu Zhifeng; Wang Bo; Zhou Yunhong

    2009-01-01

    Objective: To approach the value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice in order to improve the correctness of the diagnosis. Methods: Analysis the cases' clinical manifestation and the CT images, who were diagnosed as obstructive jaundice by operation. All of cases had high-resolution computed tomograyhy scan. The thickness and the interval is 5mm, reconstructed the thickness and the interval to 1 mm and 1.5 mm, then send the images to the workstation and MRR were processed. Analysis the date with the pathology. Results: Spiral CT thin imaging reconstruction have 98% and 93% in the accuracy of location and characterization in the obstruction. Conclusion: The spiral CT thin imaging reconstruction is a good method to improve the accuracy of location and characterization in the obstructive jaundice. (authors)

  5. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    Science.gov (United States)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Muhammad, H.; Sabarudin, A.; Ang, W. C.; Bahruddin, N. A.

    2016-03-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDIw (mGy), CTDIvol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDIvol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors.

  6. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    International Nuclear Information System (INIS)

    Karim, M K A; Hashim, S; Ang, W C; Bahruddin, N A; Bakar, K A; Muhammad, H; Sabarudin, A

    2016-01-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDI w (mGy), CTDI vol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDI vol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors. (paper)

  7. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  8. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  9. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  10. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  11. Spiral CT arthrography of the knee: technique and value in the assessment of internal derangement of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Vande B.C.; Lecouvet, F.E.; Maldague, B.; Malghem, J. [Department of Radiology, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium); Poilvache, P. [Department of Orthopedic Surgery, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2002-07-01

    Computed tomography imaging has achieved excellent multiplanar capability and submillimeter spatial resolution due to the development of the spiral acquisition mode and multidetector row technology. Multidetector spiral CT arthrography (CTA) yields valuable information for the assessment of internal derangement of the joints. This article focuses on the value of spiral CTA of the knee in the assessment of the meniscus, anterior cruciate ligament, and hyaline cartilage lesions. Advantages and disadvantages of spiral CTA with respect to MR imaging are presented. (orig.)

  12. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  13. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  14. Staging of gastric adenocarcinoma using two-phase spiral CT: correlation with pathologic staging

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won

    1998-01-01

    To correlate the preoperative staging of gastric adenocarcinoma using two-phase spiral CT with pathologic staging. One hundred and eighty patients with gastric cancers confirmed during surgery underwent two-phase spiral CT, and were evaluated retrospectively. CT scans were obtained in the prone position after ingestion of water. Scans were performed 35 and 80 seconds after the start of infusion of 120mL of non-ionic contrast material with the speed of 3mL/sec. Five mm collimation, 7mm/sec table feed and 5mm reconstruction interval were used. T-and N-stage were determined using spiral CT images, without knowledge of the pathologic results. Pathologic staging was later compared with CT staging. Pathologic T-stage was T1 in 70 cases(38.9%), T2 in 33(18.3%), T3 in 73(40.6%), and T4 in 4(2.2%). Type-I or IIa elevated lesions accouted for 10 of 70 T1 cases(14.3%) and flat or depressed lesions(type IIb, IIc, or III) for 60(85.7%). Pathologic N-stage was NO in 85 cases(47.2%), N1 in 42(23.3%), N2 in 31(17.2%), and N3 in 22(12,2%). The detection rate of early gastric cancer using two-phase spiral CT was 100.0%(10 of 10 cases) among elevated lesions and 78.3%(47 of 60 cases) among flat or depressed lesions. With regard to T-stage, there was good correlation between CT image and pathology in 86 of 180 cases(47.8%). Overstaging occurred in 23.3%(42 of 180 cases) and understaging in 28.9%(52 of 180 cases). With regard to N-stage, good correlation between CT image and pathology was noted in 94 of 180 cases(52.2%). The rate of understaging(31.7%, 57 of 180 cases) was higher than that of overstaging(16.1%, 29 of 180 cases)(p<0.001). The detection rate of early gastric cancer using two-phase spiral CT was 81.4%, and there was no significant difference in detectability between elevated and depressed lesions. Two-phase spiral CT for determing the T-and N-stage of gastric cancer was not effective;it was accurate in abont 50% of cases understaging tended to occur.=20

  15. In-vitro studies to determine the degree of stenosis using spiral-CT angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Lenk, G.; Jenett, M.; Elsner, H.; Kaiser, W.A.; Kellner, M.; Schultz, G.; Trusen, A.; Hahn, D.

    1998-01-01

    Purpose: Aim of the study was to evaluate the influence of different spiral-CT parameters for the visualisation of vascular stenoses, especially of the renal arteries. Material and methods: Models with a density equivalent to that of fat, filled with diluted contrast agent, and an inner lumen of 4, 6, 8 mm were scanned in x-, y- and z-direction. Data were acquired in up to 24 second long spiral-CT scans using different spiral-CT parameters (collimation, table speed, reconstruction algorithm, tube current). Detection of the degree of stenosis was achieved by assessment of the axial images and 3D reconstructions. Results: The best correlation between real and measured degree of stenosis was seen by using a small collimation, a low table increment and assessment of the axial images reconstructed in standard algorithm. The stenosis degrees of models directed in x- and y-direction were overestimated and those in z-direction were underestimated depending on the spiral-CT parameters. Conclusion: For optimal imaging of renal artery stenoses, collimation of 2 mm (pitch=1-2) and a reconstruction interval of 1 mm is recommended. (orig.) [de

  16. Prevalence of ligamentum arteriosum calcification on multi-section spiral CT and digital radiography.

    Science.gov (United States)

    Hong, Gil-Sun; Goo, Hyun Woo; Song, Jae-Woo

    2012-06-01

    To investigate the prevalence of ligamentum arteriosum calcification (LAC) on multi-section spiral CT and digital radiography. Five hundred and eight children and 232 adults who performed multi-section chest CT were included in this study and were divided into nine age groups: A (0-5 years), B (6-10 years), C (11-15 years), D (16-20 years), E (21-30 years), F (31-40 years), G (41-50 years), H (51-60 years), and I (61-70 years). Two radiologists assessed the presence of LAC on axial and coronal CT images, defined as focal calcific density on both or on one plane with attenuation >100 Hounsfield unit. The prevalence of LAC on CT was compared between children and adults, and between unenhanced and enhanced CT in children. The prevalence of LAC on digital radiography was evaluated in 476 children. The prevalence of definite LAC on unenhanced multi-section CT was significantly higher in children (37.8 %) than in adults (11.2 %) (P CT were 4.5, 12.8, 8.1, 19.0, 0.0, 0.0, 0.0, 2.0, and 1.9 %. In children, the prevalence of LAC was significantly higher on unenhanced than on enhanced CT (37.8 vs. 16.4 %, P children. LAC is frequently observed in children and adults on multi-section spiral CT, more frequently than previously reported. Compared with that on multi-section spiral CT, the prevalence of LAC on digital radiography is substantially low.

  17. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  18. Enhanced dual-phase spiral CT features of polypoid ampullary carcinoma

    International Nuclear Information System (INIS)

    Zeng Mengsu; Yan Fuhua; Zhou Kangrong; Chen Huiming; Chen Gang; Chen Jin

    2001-01-01

    Objective: To understand CT features of polypoid ampullary carcinoma by enhanced dual-phase spiral CT. Methods: 15 cases of polypoid ampullary carcinoma (PAC) confirmed by surgical and pathological results were studied with thin slice enhanced dual-phase spiral CT (including arterial and portal phase scanning)with retrospective analysis, the scanning parameters were 5 mm thickness and 1.0 pitch for arterial phase scanning, and 5 mm thickness and 5 mm space for portal phase scanning. Results: All cases could display an enhanced mass as local filling defect at the site of the duodenal Vater's ampulla during arterial and portal phase scanning, the tumors ranged in size from 1 cm to 5 cm with mean of 2.3 cm, all were accompanied with dilated intrahepatic and common bile duct, enlarged gallbladder and dilated pancreatic duct, except one case which had marked atrophy of the pancreatic body and tail. Conclusion: The thin slices enhanced dual-phase spiral CT could not only accurately define the level of obstruction, but also demonstrate an enhanced mass as direct CT sign of the PAC, which is crucial for diagnosis of the PAC

  19. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  20. Spiral CT features and anatomic basis of posterior pararenal space involvement in acute pancreatitis

    International Nuclear Information System (INIS)

    Min Pengqiu; Yan Zhihan; Yang Hengxuan; Liu Zaiyi; Song Bin; Wu Bing; Zhang Jin; Liu Rongbo

    2005-01-01

    Objective: To evaluate spiral CT features and anatomic basis of the posterior pararenal space (PPS) involvement in acute pancreatitis (AP). Methods: CT images of 87 cases with AP were retrospectively studied with focus on spiral CT features, incidence of the PPS involvement, and its correlations with the posterior renal fascia or lateroconal fascia. Results: Our study showed that the incidence of the PPS involvement was 47% (41/87), with Grade A 53% (46/87), Grade B 24%(21/87), and Grade C 23% (20/87), and Grade 0 53% (46/87), Grade I 22% (19/87), and Grade II 25% (22/87), respectively. The pancreatitis fluid collection in the PPS was continuous with that in the anterior pararenal space or with the fluid between the two laminae of the posterior renal fascia. In 3 follow-up cases, pseudocysts in the PPS were continuous with that in anterior pararenal space below the cone of renal fascia. Conclusion: Spiral CT features of the PPS involvement varies from mild inflammatory changes to fluid collection or phlegmonous mass. Fluid within anterior pararenal space in AP flows into the PPS by three routes. (authors)

  1. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  2. Establishment of an orthotopic lung cancer model in nude mice and its evaluation by spiral CT.

    Science.gov (United States)

    Liu, Xiang; Liu, Jun; Guan, Yubao; Li, Huiling; Huang, Liyan; Tang, Hailing; He, Jianxing

    2012-04-01

    To establish a simple and highly efficient orthotopic animal model of lung cancer cell line A549 and evaluate the growth pattern of intrathoracic tumors by spiral CT. A549 cells (5×10(6) mL(-1)) were suspended and inoculated into the right lung of BALB/c nude mice via intrathoracic injection. Nude mice were scanned three times each week by spiral CT after inoculation of lung cancer cell line A549. The survival time and body weight of nude mice as well as tumor invasion and metastasis were examined. Tissue was collected for subsequent histological assay after autopsia of mice. The tumor-forming rate of the orthotopic lung cancer model was 90%. The median survival time was 30.7 (range, 20-41) days. The incidence of tumor metastasis was 100%. The mean tumor diameter and the average CT value gradually increased in a time-dependent manner. The method of establishing the orthotopic lung cancer model through transplanting A549 cells into the lung of nude mice is simple and highly successful. Spiral CT can be used to evaluate intrathoracic tumor growth in nude mice vividly and dynamically.

  3. [Application of Low Dose Spiral CT in Diagnosing Impacted Teeth in Children and Adolescents].

    Science.gov (United States)

    Wang, Meng-tian; Li, Xue-sheng; Li, Kai-ming; Bao, Li; Ning, Gang

    2015-09-01

    [ABSTRACT] To determine the value of low dose spiral CT scanning in diagnosing impacted teeth of children and adolescents. A total of 153 children and adolescents with confirmed impacted teeth in West China Second University Hospital, Sichuan University were enrolled in this study. They were divided into 5 groups according to the different spiral CT scan parameters (tube current time product, scanning thickness and collimation value): Group A (n=30, 330 mAs, 6 X 0. 75 mm and 3. 0 mm), Group B (n=30, 140 mAs, 6 X 0. 75 mm and 3. 0 mm), Group C (n=30, 80 mAs, 6 X 0. 75 mm and 3. 0 mm), Group D (n=31, 80 mAs, 6 X 1. 50 mm and 5. 0 mm), and Group E (n=32, 50 mAs, 6 X 1. 50 mm and 5. 0 mm). There were no significant differences in general clinical features (P>0. 05) among the participants of the five groups. The phantoms were used to measure spatial resolution and contrast resolution of the scan images. Dose length product (DLP) was recorded during CT scanning for calculating effective dose (ED) of exposure. The quality of images was evaluated using a list of quality scoring criteria. (1) Under 330, 140, 80, 80 and 50 mAs, the images had a spatial resolution of 1.0 mm, with contrast resolution of 2. 0, 3. 0, 4. 5, 4. 5 and 6. 0 mm, respectively. (2) Significant differences in ED values were found among the five groups (F=1 064. 119, P=0. 000) and between every two of those groups (P0. 05). The diagnostic results of the spiral CT were consistent with those of orthodontic surgery. Low dose spiral CT scanning can meet the image quality requirements for diagnosing impacted teeth, minimizing radiation exposure effectively.

  4. Virtual endoscopy using spiral CT in patients with carcinomas of the hypopharynx and larynx

    International Nuclear Information System (INIS)

    Song, Sang Gook; Seo, Jeong Jin; Chung, Tae Woong; Kim, Hyeong Kil; Jeong, Gwang Woo; Jeong, Yong Yeon; Kang, Heoung Keun; Cho, Jae Sik

    2000-01-01

    To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the one case of glottic carcinoma was not detected. Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharyngeal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use ma complement that of axial CT. (author)

  5. Efficacy of spiral CT in the evaluation of peritoneal seeding of gastric cancer

    International Nuclear Information System (INIS)

    Choi, Hyuck Jae; Han, Joon Koo; Kim, Tae Kyoung; Kim, Ah Young; Lee, Joon Woo; Moon, Min Hoan; Yang, Han Kwang; Choi, Byung Ihn

    2001-01-01

    To determine usefulness of spiral CT in the preoperative evaluation of peritoneal seeding from a gastric carcinoma. From a database of 411 consecutive patients with surgically proven advanced gastric cancinoma obtained over a six-month period, 17 with peritoneal seeding and a control group of 24 without peritoneal seeding underwent spiral CT scanning with 7-8 mm scan thickness and interval during the portal phase. Preoperative CT images were analyzed by two readers who reached a consensus with regard to the presence and location of the ascites, thickening of the parietal peritoneum, and changes in the omentum and mesentery. Ascites was present in 47% (8/17) of patients with peritoneal seeding the right subhepatic space (n=6, 35%) and right paracolic gutter (n=5, 29%)-but not the cul-de-sac (n=2, 12%)-were common sites of fluid collection. Permeative changes in the omentum and mesentery were seen in 18% (3/17) and 12% (2/17) of patients, respectively. Among five controls with false positive results, ascites in the cul-de-sac was present in three (two males and one female, 12%) while omental nodules and a thickened peritoneum were found in two (8%) and one (4%), respectively. In nine controls with false negative results, small disseminated nodules were seen in the mesentery and omentum at surgical field. The sensitivity and specificity of spiral CT were 47% (8/17) and 79% (19/24), respectively. In terms of sensitivity and specificity, spiral CT is not especially accurate in distinguishing peritoneal seeding from gastric carcinoma

  6. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  7. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W.; Kuwert, T. [Nuklearmedizinische Klinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Beckmann, M.W. [Frauenklinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Forst, R. [Lehrstuhl fuer Orthopaedie mit Orthopaedischer Chirurgie, Friedrich-Alexander Univ. Erlangen/Nuernberg (Germany); Bautz, W. [Radiologisches Inst., Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany)

    2005-07-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  8. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    International Nuclear Information System (INIS)

    Roemer, W.; Kuwert, T.; Beckmann, M.W.; Forst, R.; Bautz, W.

    2005-01-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  9. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    International Nuclear Information System (INIS)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs

  10. The potentials of spiral CT for detection of focal liver lesions

    International Nuclear Information System (INIS)

    Helmberger, H.; Kersting-Sommerhoff, B.; Lenz, M.; Kirsten, R.; Bautz, W.

    1996-01-01

    Spiral CT currently is the modality of choice for all aspects of diagnostic evaluation of the liver. Optimal selection of treatment should be based inter alia on the findings obtained by spiral CT with arterial application of contrast medium, as for example S-CTA (primary liver tumors), or S-CTAP (secondary liver tumors). Ultrasonography is the major supplementing modality. In the near future, MR imaging applying liver-specific contrast-enhancing agents is expected to become an important competing technique, and further developments of interest in diagnostic imaging of the liver are in the offing: it is not yet known which technique will be the modality of choice at the onset of the 21st century. (orig.) [de

  11. Technique and value of three dimensional reconstruction of stones in the renal pelvis using spiral CT

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Pentenrieder, M.; Kohz, P.; Englmeier, H.K.; Schmeller, N.

    1994-01-01

    5 patients with staghorn calculi in the renal pelvis were examined by spiral CT. From the raw data three dimensional reconstructions of the stones were obtained. In all patients it was possible to compare the three dimensional model with the stone following performance of percutaneous lithopaxy and endoscopic removal of the fragments. In all cases the three dimensional reconstruction provided a realistic image of the stones and was of practical value for the urologist for preoperative diagnosis and intraoperative control. (orig.) [de

  12. Wedge-shaped parenchymal enhancement peripheral to the hepatic hemangioma : two-phase spiral CT findings

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han, Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Song, Chi Sung; Choi, Byung Ihn

    2000-01-01

    To determine the incidence of hepatic hemangiomas associated with wedge-shaped parenchymal enhancements adjacent to the tumors as seen on two-phase spiral CT images obtained during the hepatic arterial phase and to characterize the two-phase spiral CT findings of those hemangiomas. One hundred and eight consecutive hepatic hemangiomas in 63 patients who underwent two-phase spiral CT scanning during an 11-month period were included in this study. Two-phase spiral CT scans were obtained during the hepatic arterial phase (30-second delay) and portal venous phase (65-second delay) after injection of 120 mL of contrast material at a rate of 3 mL/sec. We evaluated the frequency with which wedge-shaped parenchymal enhancement was adjacent to the hemangiomas during the hepatic arterial phase and divided hemangiomas into two groups according to whether or not wedge-shaped parenchymal enhancement was noted (Group A and Group B). The presence of such enhancement in hemangiomas was correlated with tumor size and the grade of intratumoral enhancement. In 24 of 108 hemangiomas, wedge-shaped parenchymal enhancement adjacent to hepatic tumors was seen on two-phase CT images obtained during the hepatic arterial phase. Mean hemangioma size was 22mm in group A and 24mm in group B. There was no statistically significant relationship between lesion size and the presence of wedge-shaped parenchymal enhancement adjacent to a hemangioma. In 91.7% and 100% of tumors in Group A, and in 9.6% and 17.8% in Group B, hemangiomas showed more than 50% intratumoral enhancement during the arterial and portal venous phase, respectively. Wedge-shaped parenchymal enhancements peripheral to hepatic hemangiomas was more frequently found in tumors showing more than 50% intratumoral enhancement during these two phases (p less than 0.01). Wedge-shaped parenchymal enhancements is not uncommonly seen adjacent to hepatic hemangiomas on two-phase spiral CT images obtained during the hepatic arterial phase. A

  13. Functioning islet cell tumor of the pancreas. Localization with dynamic spiral CT

    International Nuclear Information System (INIS)

    Chung, M.J.; Choi, B.I.; Han, J.K.; Chung, J.W.; Han, M.C.; Bae, S.H.

    1997-01-01

    Purpose: The purpose of this study was to evaluate the usefulness of dynamic spiral CT, including multidimensional reformation, in the detection and localization of islet cell tumors of the pancreas. Material and Methods: Seven patients with histopathologically proven functioning islet cell tumors of the pancreas were studied with 2-phase contrast-enhanced spiral CT. Scanning of the arterial phase and late phase was started 30 s and 180 s, respectively, after injection of 100 ml of contrast medium at a rate of 3 ml/s. Results: Axial images in the arterial phase depicted the lesions in 5 patients, but in the late phase in only one patient. Multiplanar reformatted images of the arterial phase depicted the lesions in all 7 patients. Maximal intensity projection images demonstrated all lesions with information of their relationship to the vascular structure. Conclusion: Dynamic spiral CT with scanning during the arterial phase and retrospective multidimensional reformation is useful for preoperative detection and localization of small islet cell tumors of the pancreas. (orig.)

  14. Spiral CT in kidney: assumption of renal function by objective evaluation of renal cortical enhancement

    International Nuclear Information System (INIS)

    Choi, Bo Yoon; Lee, Jong Seok; Lee, Joon Woo; Myung, Jae Sung; Sim, Jung Suk; Seong, Chang Kyu; Kim, Seung Hyup; Choi, Guk Myeong; Chi, Seong Whi

    2000-01-01

    To correlate the degree of renal cortical enhancement, objectively evaluated by means of spiral CT with the serum level of creatinine, and to determine the extent to which this degree of enhancement may be used to detect renal parenchymal disease. Eighty patients (M:F = 50:30; age + 25-19, (mean 53) years) with available serum level of creatinine who underwent spiral CT between September and October 1999 were included in this study. In fifty patients the findings suggested hepatic or biliary diseases such as hepatoma, biliary cancer, or stone, while in thirty, renal diseases such as cyst, hematoma, or stone appeared to be present. Spiral CT imaging of the cortical phase was obtained at 30-40 seconds after the injection of 120 ml of non-ionic media at a rate of 3 ml/sec. The degree of renal cortical enhancement was calculated by dividing the CT attenuation number of renal cortex at the level of the renal hilum by the CT attenuation number of aorta at the same level. The degree of renal cortical enhancement was compared with the serum level of creatinine, and the degree of renal cortical enhancement in renal parenchymal disease with that of the normal group. Among eighty patients there were five with renal parenchymal disease and 75 with normal renal function. The ratio of the CT attenuation number of renal cortex to that of aorta at the level of the renal hilum ranged between 0.49 and 0.99 (mean, 0.79; standard deviation, 0.15). while the serum level of creatinine ranged between 0.6 and 3.2 mg/dl. There was significant correlation (coefficient of -0.346) and a statistically significant probability of 0.002 between the ratio of the CT attenuation numbers and the serum level of creatinine. There was a significant difference (statistically significant probability of less than 0.01) between those with renal parenchymal disease and the normal group. The use of spiral CT to measure the degree of renal cortical enhancement provides not only an effective index for

  15. Power doppler ultrasound findings of renal infarct after experimental renal artery occlusion: comparison with spiral CT

    International Nuclear Information System (INIS)

    Jung, Seung Eun; Shinn, Kyung Sub; Kim, Hak Hee; Mun, Seok Hwan; Lee, Young Joon; Lee, Bae Young; Choi, Byung Gil; Lee, Jae Mun; Lee, Hee Jeong

    1999-01-01

    To evaluate the efficacy of power Doppler ultrasonography (PDUS) in depicting renal infarction in rabbits during experimental renal segmental arterial occlusion, and to compare the results with those of CT scanning. In 28 rabbits weighing 2.5 4kg, the segmental renal artery was occluded through the left main renal artery by embolization with Ivalon (Nycomed, Paris, France). Power Doppler ultrasonography and spiral CT scanning were performed before and at 2, 5, 8, 15, and 24 hours, and 3 and 7 days after occlusion of the segmental renal artery. The location of infarcted areas and collaterals, as seen on PDUS and CT scans, was evaluated by two radiologists. In all cases, as seen on power Doppler ultrasonography, infarcted areas-when compared with normal parenchyma, clearly demonstrated wedge-shaped perfusion defects in the kidney. The location of the lesion closely corresponded to the location seen during CT scanning. After renal arterial occlusion, transiently congested capsular arteries, which were named 'capsular sign', were seen in 63% of rabbits in the two and five-hour groups. No significant cortical rim sign was demonstrated on power Doppler ultrasonography, though it was noted on spiral CT at 15 and 24 hours, and 3 and 7 days after renal arterial occlusion. Power Doppler ultrasonography was useful for the diagnosis of renal infarction. Congested capsular artery seen in the early stage of renal infarction might be a characteristic finding of this condition, as seen on power Doppler ultrasonography

  16. Pulmonary spheral tuberculosis: features and clinical significance of spiral dynamic CT

    International Nuclear Information System (INIS)

    Xie Ruming; Ma Daqing; Li Tieyi; Chen Yi; Lu Fudong; Zhou Xinhua

    2001-01-01

    Objective: To assess the features and clinical significance of spiral dynamic CT in patients with pulmonary spheral tuberculosis. Methods: The 54 foci in 42 patients with pulmonary spheral tuberculosis were studied. Thin-sections at 2 mm thickness and 2 mm interval through the nodular center were obtained before and after administration of contrast material. Results: In 54 pulmonary spheral tuberculosis, maximum enhanced CT value in 51 (94.4%, 51/54) foci was less than 20 HU, and more than 20 HU in the other 3(5.6%, 3/54) foci. 27(50.0%, 27/54) foci showed no any enhancement, 24, (44%, 24/54) foci showed capsular enhancement, 1(1.9%, 1/54) focus showed peripheral enhancement and 2(3.7%, 2/54) foci showed extensive enhancement. The accuracy of the correct diagnosis was 25.9% in terms of plain CT and 94.4% in terms of enhanced CT scanning. The difference was significant (x 2 = 50.1, P < 0.05). The curative effect of extensive enhanced foci and peripheral enhanced foci was optimal, capsular enhanced foci was second, and non-enhanced foci was barely satisfactory. Conclusion: Spiral dynamic CT technique may improve the accuracy of diagnosing pulmonary spheral tuberculosis. No enhancement and/or capsular enhancement were suggestive of tuberculosis. The enhancing character of foci might contribute to assess the curative effect of anti-tuberculosis

  17. Noninvasive diagnosis of suspected severe pulmonary embolism. Trans-esophageal echocardiography vs spiral CT

    International Nuclear Information System (INIS)

    Pruszczyk, P.; Torbicki, A.; Pacho, R.

    1998-01-01

    Patients with pulmonary embolism (PE) and echocardiographic signs of right ventricular over-lead have worse prognosis and may be require aggressive therapy. Unequivocal confirmation of PE is required before thrombolysis or embolectomy. This study compares the value of trans-esophageal echocardiography (TEE) and spiral CT (sCT) in direct visualization of pulmonary artery thrombo-emboli in patients with suspected PE and echocardiographic signs of right ventricular over-lead. Because of high prevalence of bilateral central pulmonary thrombo-emboli in patients with hemo-dynamically significant PE, both sCT and TEE allow its definitive confirmation in most cases. Thrombi reported by sCT distally to lobar arteries should be interpreted with caution. (author)

  18. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  19. Spiral CT angiography of middle cerebral artery stenoses

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Neff, K.W.; Ries, S.; Sommer, A.; Steinke, W.; Georgi, M.

    1996-01-01

    Transcranial Doppler ultrasonography (TCD) and magnetic resonance angiography (MRA) are well-established techniques for ascertaining intracranial obstructive artery disease. The short examination time required for additional helical CT angiography (CTA) allows quick management of emergency patients already undergoing native CT. However, today the ability of CTA to detect stenoses of the middle cerebral artery (MCA) has not been proven. To analyse the value of CTA in the classification of atherosclerotic disease 23 MCA stenoses confirmed by TCD and MRA were investigated. CTA was performed on a Hispeed advantage scanner (GE) using a bolus injection of 70 ml KM and 40 ml NaCl with a flow rate of 2.5 ml/s, a thickness of 1 mm, a pitch of 1.5 and a 1 mm increment. CTA was presented as maximum intensity projection (MIP) and as multi-projection volume reconstruction (MPVR). A three-step classification of stenosis was compared with the results of TCD and MRA. Good opacification of the MCA was achieved in M1 and M2 segments in all patients. Classification of stenosis by CTA agreed with MRA and TCD in 14 cases; 7 stenoses were assigned to a lower classification by CTA. Two lowgrade stenoses could not be proven by CTA. Although MIP and MPVR yield the same result in stenosis classification MPVR showed a sharper image quality. In contrast to MRA, veins were highly opacified in CTA. Artery and vein were sometimes superimposed, which had to be avoided by changing the projection angle. Medium- and high-grade MCA stenoses can be demonstrated by CTA quickly and reliably. Compared to MRA and TCD, CTA provides lower grading of stenosis. (orig.) [de

  20. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  1. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.; Tylen, U.; Aspelin, P.

    2002-01-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  2. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Department of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Department of Radiology, Danderyds Hospital, Danderyd (Sweden); Tylen, U. [Deparment of Radiology, Sahlgrenska University Hospital, Gothenberg (Sweden); Aspelin, P. [Department of Radiology, Huddinge University Hospital, Huddinge (Sweden)

    2002-05-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  3. Advanced single-slice rebinning for tilted spiral cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Fuchs, Theo; Schaller, Stefan; Kalender, Willi A.

    2001-01-01

    Future medical CT scanners and today's micro CT scanners demand cone-beam reconstruction algorithms that are capable of reconstructing data acquired from a tilted spiral trajectory where the vector of rotation is not necessarily parallel to the vector of table increment. For the medical CT scanner this case of nonparallel object motion is met for nonzero gantry tilt: the table moves into a direction that is not perpendicular to the plane of rotation. Since this is not a special application of medical CT but rather a daily routine in head exams, there is a strong need for corresponding reconstruction algorithms. In contrast to medical CT, where the special case of nonperpendicular motion is used on purpose, micro CT scanners cannot avoid aberrations of the rotational axis and the table increment vector due to alignment problems. Especially for those micro CT scanners that have the lifting stage mounted on the rotation table (in contrast to setups where the lifting stage holds the rotation table), this kind of misalignment is equivalent to a gantry tilt. We therefore generalize the advanced single-slice rebinning algorithm (ASSR), which is considered a very promising approach for medical cone-beam reconstruction due to its high image quality and its high reconstruction speed [Med. Phys. 27, 754-772 (2000)], to the case of tilted gantries. We evaluate this extended ASSR approach (which we will denote as ASSR + , for convenience) in comparison to the original ASSR algorithm using simulated phantom data for reconstruction. For the case of nonparallel object motion ASSR + shows significant improvements over ASSR, however, its computational complexity is slightly increased due to the broken symmetry of the spiral trajectory

  4. Pitfalls in the use of spiral CT for identification of intracranial aneurysms

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Dorsch, N.W.C.

    1999-01-01

    We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms. (orig.)

  5. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  6. Risk-benefit analysis and cost-effectiveness analysis of lung cancer screening by spiral CT

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1999-01-01

    Mass screening of lung cancer has been widely performed using indirect chest X-ray method in Japan. However reduction of the mortality for lung cancer is questioned. We have proposed that recently developed spiral CT should be adopted for the screening of lung cancer, since CT has an excellent detectability for small nodule. Lung Cancer Screening CT (LSCT) has been developed by author's group using spiral CT with low dose and light weight in order to make a mobile unit. In this paper risk-benefit analysis and cost-effectiveness analysis are described for the LSCT screening of lung cancer. As a risk, radiation carcinogenesis due to exposure from LSCT are compared with gain of life-expectancy by screening and men of 40 years or more and women of 45 years or more are justified. The cost per person-year is estimated for LSCT screening which is better than that of present method, although total cost is higher. The LSCT screening could be recommended if total cost is affordable. (author)

  7. Application of CT three-dimensional reconstruction in elbow injury

    International Nuclear Information System (INIS)

    Liang Wenhua; Qian Li

    2009-01-01

    Objective: To investigate the application of multi-slice spiral CT in fracture of elbow, and to study the value of different methods of the reconstruction. Methods: Thin line cross-section spiral CT scan was carried out in 13 cases with elbow injury, three-dimensional reconstruction was completed later. Several reconstructed image quality to display f the elbow fracture and dislocation were analyzed and compared. Results: 13 cases (17) elbow trauma included humeral media epicondyle fracture, humeral external epicondyle fracture, intercondylar fracture, olecranal fracture and radial head fracture. Among them, X-ray film showed negative in three sites, showed suspect fractures in 2 cases, and only showed single fracture in 2 cases. MPR reconstruction image could not only identify the diagnosis of fracture, but also provide further multi-angle display on fracture line and the extent of articular surface involvement. Surface reconstruction technology could exclude the impact of passive elbow flexion and display elbow injury more intuitively. Conclusion The elbow fracture dislocation could be showed clearly in multi-slice spiral CT, especially for complex fractures, with unmatched advantages compared to X-ray for clinical diagnosis and treatment determination. (authors)

  8. Evaluation of spiral CT in staging of colon and rectum carcinoma

    International Nuclear Information System (INIS)

    Hundt, W.; Braunschweig, R.; Reiser, M.

    1999-01-01

    The purpose of our study was to evaluate the capability of a subsecond spiral-CT scanner using two contrast medium phases in staging of colorectal cancer. In our study we included 37 patients with proven rectum or colon carcinoma. Spiral CT was performed following tap-water enema of the colon in the arterial and venous phases of contrast medium enhancement. Our results were compared with the findings of pathological examination after surgery. The tumor's size and extension were evaluated in the arterial and venous phases, the lymph nodes in the venous phase of the CT scan. The tumor was in the rectum (n = 14), sigma (n = 11), descending colon (n = 6), and cecum (n = 6). Two-phase spiral CT had a sensitivity of 97.2 % in the arterial phase and 89.1 % in the venous phase in detecting the carcinoma. The staging results were in the arterial phase in 30 of 37 cases (81.0 %) and in the venous phase in 24 of 37 cases (64.8 %) according to pathology. In 27 of 32 patients (84.3 %) lymph nodes were detected. The correct classification of the N-stage was possible in 23 of 34 cases (67.6 %). The combined use of arterial and venous phases in staging of colorectal cancer can improve the T- and N-stage classification in comparison with using only one contrast medium phase. The arterial phase is superior compared with the venous phase for local tumor staging and the venous phase is used for lymph node assessment. (orig.) (orig.)

  9. Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies

    International Nuclear Information System (INIS)

    Applegate, K.E.; Dardinger, J.T.; Herts, B.R.; Davros, W.J.; Obuchowski, N.A.; Lieber, M.L.; Maneker, A.

    2001-01-01

    Background:. Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. Objective: To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. Materials and methods: Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. Results: The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity < 35 %). The optimal technique for visualizing the LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. Conclusion: Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized. (orig.)

  10. Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies.

    Science.gov (United States)

    Applegate, K E; Dardinger, J T; Lieber, M L; Herts, B R; Davros, W J; Obuchowski, N A; Maneker, A

    2001-12-01

    Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized.

  11. A study of parameters in spiral CT volumetry using balloon phantoms

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Han, Joon Koo

    2001-01-01

    To evaluate the effects of threshold values, reconstruction interval, slice thickness and table speed on the spiral CT volumetry. Two phantoms made of a balloon and diluted contrast media underwent spiral CT scanning with section thicknesses of 5, 7 and 10 mm and table speeds of 5, 8 and 10 mm with scans of 5 mm section thickness, 7, 10, and 14 mm with scans of 7 mm section thickness, and 10, 15, and 20 mm with scans of 10 mm section thickness. The volumetric values of phantom A and B were obtained at varying threshold values and a reconstruction interval of 5 and 10 mm for all scans. Volumes were also determined with the threshold value fixed and a reconstruction interval of 1, 5, 7 and 10 mm, respectively. Three-dimensional display and volumetric measurements were obtained using reconstructed images. The effects of threshold value, reconstruction interval, slice thickness and table speed on volumetry were analyzed. Volumetric values varied according to threshold values. Where a threshold value was low, value increased as pitch increased, but where a the threshold value was high, value decreased as pitch increased. With varying threshold values, measurement errors in CT volumetry were 1.6 to 9.0%. Volume decreased as reconstruction interval increased. Where the table speed/ slice thickness ratio was constant, volume was constant though slice thickness differed. At fixed threshold values, variation in the reconstruction interval was statistically more significant than variation in slice thickness or table speed (p<0.05, Kruskal-Wallis one-way ANOVA). Among serveral spiral scanning and image reconstruction parameters including threshold value, reconstruction interval, slice thickness, and table speed, threshold value most affected the result obtained. At fixed threshold values, the reconstruction interval used had more effect on CT volumetry than other parameters

  12. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    International Nuclear Information System (INIS)

    Reissig, Angelika; Heyne, Jens-Peter; Kroegel, Claus

    2004-01-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli

  13. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    Energy Technology Data Exchange (ETDEWEB)

    Reissig, Angelika E-mail: angelika.reissig@med.uni-jena.de; Heyne, Jens-Peter; Kroegel, Claus

    2004-03-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli.

  14. Clinical application of 3D spiral CT of the auditory ossicular chain and labyrinth: Preliminary report

    International Nuclear Information System (INIS)

    Huang Yong; Wang Yisheng

    1998-01-01

    Purpose: To assess the clinical application and limitation of 3D spiral CT of the auditory ossicular chain and labyrinth. Methods: 3D reconstruction of the auditory ossicular chain and labyrinth, including multiplanar reformation (MPR), minimum or maximum intensity projection (MinIP or MaxIP) and shaded surface display (SSD), were performed with 1 mm slice thickness, 5 cm field of view and 0.1 mm reconstruction interval spiral CT in 14 normal subjects, 15 patients with middle ear diseases. Results: With use of 3D reconstruction images in 14 normal subjects, 13 cases of ossicular chain showed that the long process of the incus was parallel to the manubrium and projected inferomedian toward the cochlear promontory, the incus-stapedial joint was like a 'L-shape' structure, and in 8 cases of labyrinth reconstruction, the cochlea and the three semicircular canals were demonstrated. 9 cholesteatomas of 13 chronic otitis media demonstrated destruction of ossicular chain of varying degrees. In 2 cases with congenital abnormality, ossicle dysplasia was seen. Conclusion: 3D CT is a useful technique for evaluating anatomic malformations and diseases of middle and inner ear, but there are still few pitfalls

  15. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    International Nuclear Information System (INIS)

    Mastora, I.; Remy-Jardin, M.; Remy, J.; Suess, C.; Scherf, C.; Guillot, J.P.

    2001-01-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  16. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, I.; Remy-Jardin, M.; Remy, J. [Dept. of Radiology, University Center Hospital Calmette, Lille (France); Medical Research Group, Lille (France); Suess, C.; Scherf, C. [Siemens Medical Systems, Forcheim (Germany); Guillot, J.P. [Dept. of Radiology, University Center Hospital Calmette, Lille (France)

    2001-04-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  17. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  18. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    International Nuclear Information System (INIS)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N.

    2006-01-01

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results

  19. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N. [Medical Univ. of Bologna, S. Orsola-Malpighi Policlinic (Italy). Dept. of Radiology

    2006-10-15

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results.

  20. ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Funke, M.; Obenauer, S.; Baum, F.; Grabbe, E.

    2003-01-01

    AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted κ statistics, extended κ statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended κ=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended κ=0.91 and 0.73, respectively), weighted κ=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not

  1. Spiral CT and optimization of the modalities of the iodinated intravenous contrast material: Experimental studies in human pathology

    International Nuclear Information System (INIS)

    Bonaldi, V.

    1998-01-01

    Spiral (or helical) CT represents the most recent improvement in the field of computed assisted tomography (CAT scan). The capabilities of this new imaging modality are much superior to these of conventional CT scanning; then result from the rapid acquisition and from the volumetric nature of the derived data set. The short time of data acquisition had made mandatory the revision of protocols for intravenous administration of iodinated contrast material. By the means of several studies, carried out on pathologic and healthy patients, we have attempted to improve knowledge in factors influencing CT attenuation values after injection of contrast material, in the aim of improving contrast administration performed during spiral CT scanning. Anatomical landmarks that we have studied till now have been liver, the pancreas, the kidney and the cervical spine. In addition, a paired based methodology has been used. The volumetric set of data derived from spiral CT scanning leads to optimal post-processing tasks, the most interesting being related to cine-display and multiplanar reformatting; both modalities have been evaluated, about the pancreas and the musculo-skeletal system respectively. Conversely, this new modality, as for other imaging modalities, is responsible for additional costs derived from restless increase in the number of images to be dealt with and from the occurrence of new tasks (in post-processing particularly). The place of spiral CT in diagnostic strategies among other modern imaging modalities should be assessed, especially with respect to Magnetic Resonance Imaging (MRI). (author)

  2. Spiral-CT-angiography of acute pulmonary embolism: factors that influence the implementation into standard diagnostic algorithms

    International Nuclear Information System (INIS)

    Bankier, A.; Herold, C.J.; Fleischmann, D.; Janata-Schwatczek, K.

    1998-01-01

    Purpose: Debate about the potential implementation of Spiral-CT in diagnostic algorithms of pulmonary embolism are often focussed on sensitivity and specificity in the context of comparative methodologic studies. We intend to investigate whether additional factors might influence this debate. Results: The factors availability, acceptance, patient-outcome, and cost-effectiveness-studies do have substantial influence on the implementation of Spiral-CT in the diagnostic algorithms of pulmonary embolism. Incorporation of these factors into the discussion might lead to more flexible and more patient-oriented algorithms for the diagnosis of pulmonary embolism. Conclusion: Availability of equipment, acceptance among clinicians, patient-out-come, and cost-effectiveness evaluations should be implemented into the debate about potential implementation of Spiral-CT in routine diagnostic imaging algorithms of pulmonary embolism. (orig./AJ) [de

  3. Use of spiral CT in demonstrating early carcinoma of the stomach - I stage

    International Nuclear Information System (INIS)

    Pomakov, P.

    2009-01-01

    Full text: The aim of this lecture is to provide practical information about the methodology and technique of spiral computed tomography, which provide maximum diagnostic efficiency in early gastric cancer - I stage, and to present the semiotics of CT images seen in early gastric cancer stage I - a own and literature data. Methodology of the study covers optimal drug muscle relaxation of the abdominal wall by injection of 2 sg buskolizin intravenous; maximum distension of the stomach lumen by ingestion of 3 effervescent disintegrated tablets Vit. C with 1-2 sips of water, necessarily using of non-ionic contrast media - 100 ml / 300 mg iodine / 1 ml liquid bolus introduced for 30 seconds. Start scanning - 30 seconds of the start of injection - to visualize the arterial phase, use of slices with a thickness of 3 mm and 2 mm interval; exponential data 120 kV, 160 mAc. Earlier form of gastric cancer have to be presented by 5 CT image: unequal unsmooth, scallop or polycyclic contours of the lining, thinning the complete disappearance of the lining; undulating thickening of the lining; nodal formation like a polyp on a broad basis with a 2-5 mm, double contour of the lining - like a wave. These amendments are localized only in a limited segment of the gastric mucosa. Spiral CT is an effective diagnostic performance in gastric cancer, including the early stage I of cancer development. This is realized only by using the specific methodology of the study as well as good knowledge of the CT images semiology for carcinoma, localized only within a certain perimeter of the stomach lining

  4. Diagnosis and staging of carcinoma localized in the antral part of the stomach with spiral CT

    International Nuclear Information System (INIS)

    Pomakov, P.; Grudeva, V.; Mlachkova, D.

    2009-01-01

    The aim of the study was to characterize CT images and stages of carcinomas localized in the antral part of the stomach obtained with spiral CT. Seven men aged from 54 years old to 81 years old inclusive, with subjective complaints and clinical suspicion of a neoplasm in the upper gastrointestinal tract were examine Examinations were performed following stomach wall re relaxation with Buscolysin.The stomach is distended by drinking 600 ml of water. Upper abdomen scans were performed with spiral CT/e General Electric with the following parameters: slice thickness 3-5 mm, spacing 3 mm, pitch 1,5, reconstruction index 3 mm. After the pre-contrast scans, 100 ml of non-ionic contrast media is administered intravenously with an injection rate of 30 ml/sec. Scan delay time - 30 seconds after start of injection. Exposition data-120 kV, 180 mAs. Carcinoma localized in the antral part of the stomach was demonstrated in 7 patients. The staging showed: I stage - one patient, II stage - 2, III stage - 1 and IV stage - three patients. According to the macro morphological characteristic: exophytic type - 4, endophytic tumor - 1, ulcerous tumor - 1 and early carcinoma - 1 patient. In our material only male patients were present. Early carcinoma was demonstrated in a male patient at an age of 80 years old. An enhancing nodular local thickness was visualized. Differential diagnosis between malignant and benign ulcer is necessary in certain cases. It is performed on the contrast scans, the malignant process enhances twice its density, When performing a purposive CT examination it is possible to diagnose neoplasms in the antral part of the stomach, from stage i to IV with different macro morphologic characteristic

  5. Spiral CT of the pancreas. The value of small field-of-view targeted reconstruction

    International Nuclear Information System (INIS)

    Nishiharu, T.; Yamashita, Y.; Ogata, I.; Sumi, S.; Mitsuzaki, K.; Takahashi, M.

    1998-01-01

    Purpose: To compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases. Material and methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols. Results: The high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). In patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details. Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities. (orig.)

  6. Spiral CT features of abdomen after whipple's operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Lee, K. Y.; Shin, K. H.; Jung, M. H.; Park, C. M.; Cha, I. H. [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To assess the CT features of postoperative anatomical changes, surgical complications, and patterns of tumor recurrence after Whipple's operation. 42 spiral CT scans of 31 patients who had undergone Whipple's operation were retrospectively reviewed. Postoperative diagnoses were distal CBD cancer in 13 patients, cancer of the ampulla of Vater in ten, cancer of the head of the pancreas in seven, and microcystic cystadenocarcinoma of the pancreas in one. Time intervals between surgery and CT ranged from 1 week to 5 years. CT features of postoperative anastomotic changes, surgical complications, and patterns of tumor recurrence were analyzed. Gastro- or duodeno-jejunal anastomosis was seen in 32 CT scans(74%), pancreaticojejunostomy in 27(64%), and choledochojejunostomy in 24(57%). Pneumobilia was seen in ten patients(34%). Abnormal fluid collections in the peripancreatic and perihepatic space were demonstrated in two patients who underwent CT scans within 3 weeks after operation. Other complications included wound abscess(n=2), and portal vein occlusion(n=1). The most common site of metastasis was the lymph node(n=8)(retroperitoneal:n=5; mesentery root:n=4; and celiac:n=2), followed by the liver(n=6), peritoneum(n=3), adrenal gland(n=2), and afferent loop(n=1). In three cases, there was local recurrence in the pancreatic bed. To reduce possible diagnostic errors during CT interpretation, a Knowledge of normal postoperative anatomy, common complications, and patterns of disease recurrence following Whipple's operation is important.

  7. Application of the FDK algorithm for multi-slice tomographic image reconstruction; Aplicacao do algoritmo FDK para a reconstrucao de imagens tomograficas multicortes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto, E-mail: pcosta@if.usp.b [Universidade de Sao Paulo (IFUSP), SP (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear; Araujo, Ericky Caldas de Almeida [Fine Image Technology, Sao Paulo, SP (Brazil)

    2010-08-15

    This work consisted on the study and application of the FDK (Feldkamp- Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an X-ray equipment and a digital image detector charge-coupled device type were used. The FDK algorithm was implemented on a computer with a Pentium{sup R} XEON{sup TM} 3.0 processor, which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution ({mu}(r)) was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose distribution {mu}(r) was unknown. Some aspects of the reconstructed images were analyzed to assess the robustness and reproducibility of the system. During the system calibration, a linear relationship between CT number and linear attenuation coefficients of materials was verified, which validate the application of the implemented multi-slice tomographic system for the characterization of linear attenuation coefficients of distinct several objects. (author)

  8. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  9. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  10. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  11. Quantitative evaluation in enhancement of pancreas and adjacent vessels during spiral CT

    International Nuclear Information System (INIS)

    Kim, Hyoung Seuk; Shin, Kue Hee; Park, Cheol Min; Cha, Sang Hoon; Chung, Kyoo Byung

    1997-01-01

    To determine by quantitative evaluation of pancreatic and adjacent vascular enhancement during spiral CT, the ideal scan delay for examination of the pancreas. Dual(n=3D90) and triple(n=3D90) phase spiral CT scans of patients whose pancreas showed no pathologic condition were retrospectively evaluated. Dual-phase scans were performed at 43 seconds(early), and 5-6 minutes(delayed) after the injection of 120ml of contrast material at an injection rate of 3ml/sec;triple-phase scans were performed at 25 seconds(arterial),60-65 seconds (portal) and 5-6 minutes (delayed) after the injection of 120-140ml of contrast material at an injection rate of 2-4ml/sec, and ten patients also underwent precontrast scanning. CT attenuation values(HU) were measured in the head, body and tail of the pancreas, aorta, and main portal vein during each phase of all scans. Triple-phase protocol was used to measure the effect of different total volumes and injection rates on enhancement of the pancreas and adjacent vessels. There was no significant difference in the degree of enhancement of the pancreas head, body and tail during each phase(p>0.05). The pancreas was maximally enhanced on 43 second delayed scan(132±20HU)(p 0.05). The main portal vein showed maximum enhancement on 43-second delayed scan(207±44HU)(p<0.05). Different total volume of contrast material did not change the enhancement of the pancreas and adjacent vessels. At an injection rate of 2ml/sec, peak enhancement of the pancreas, aorta and portal vein was obtained on 60-65 second delayed scan, and at 4ml/sec, peak enhancement was obtained on 25 second delayed scan(p<0.05). Observing the usual protocols for abdominal spiral CT scanning, the pancreas was most effectively evaluated using a 43-second delayed scan. An increased injection rate resulted in earlier enhancement of the pancreas, aorta and portal vein

  12. Malignant focal hepatic lesions complicating underlying liver disease: dual-phase contrast-enhanced spiral CT sensitivity and specificity in orthotopic liver transplant patients

    International Nuclear Information System (INIS)

    Mortele, K.J.; De Keukeleire, K.; Praet, M.; Van Vlierberghe, H.; Hemptinne, B. de; Ros, P.R.

    2001-01-01

    The aim of this study was to determine the accuracy of contrast-enhanced biphasic spiral CT as a screening tool in the preoperative evaluation of orthotopic liver transplant (OLT) patients. Spiral-CT examinations were performed before liver transplantation in 53 patients. Scans were retrospectively reviewed and compared with pathologic findings in fresh-sectioned livers. When findings between spiral CT and pathology were discordant, formalized livers were reexamined with lesion-by lesion evaluation. Fresh pathologic evaluation revealed 23 liver lesions (16 HCC, 7 macro-regenerative nodules). Malignancy was identified in 13 of 53 patients (24.5%). Pre-transplantation spiral CT depicted 27 liver lesions (23 HCC, 4 macro-regenerative nodules). Malignancy was suspected in 14 patients (26.4%). In 10 of 53 (18.9%), spiral CT and pathologic evaluation were discordant. Subsequent retrospective pathologic evaluation showed malignancy in 4 additional patients. Spiral CT compared with the retrospective pathologic findings revealed 36 real-negative, 14 real-positive, 0 false-positive, and 3 false-negative patients with malignancy. Sensitivity and specificity of spiral CT in detection of malignancy was 82 and 100%, respectively. Contrast-enhanced biphasic spiral CT is an accurate technique in the evaluation of patients preceding OLT. Routine fresh-sectioned liver pathologic findings are not as sensitive as previously estimated. (orig.)

  13. Correlation between spiral CT features of pericolic infiltration and tumor angiogenesis in colorectal carcinoma

    International Nuclear Information System (INIS)

    Zhang Ruiping; Li Jianding

    2007-01-01

    Objective: To investigate the correlation of spiral CT (SCT) features with pathology, microvessel density (MVD), expression of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2( MMP-2) in colorectal carcinoma. Methods: Forty patients with colorectal carcinoma confirmed by operation were examined by SCT. The resected tumor specimens were immunohistochemically stained for the expression of VEGF, MMP-2 and the calculation of MVD. Results: The accuracy of SCT in depicting the pericolic and wall infiltration was 92.5%. The metastasis rates of colorectal cancer with pericolic infiltration and wall infiltration were 75.0% and 33.3%, respectively, the differences were statistically significant between the two groups (P<0.05). The differences of CT enhancement value, MVD, expressions of VEGF and MMP-2 between the two groups were statistically significant (P<0.05). The enhancement degree of CT had a positive correlation with MVD (P<0.05). Conclusion: SCT is accurate for depicting pericolic and wall infiltration, pericolic infiltration in colorectal carcinoma indicates the tendency of metastasis. The enhancement degree of CT might be used to quantitatively evaluate the tumor angiogenesis, expressions of VEGF and MMP-2 and MVD are closely correlated with the infiltration of colorectal cancer. (authors)

  14. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  15. Coronary artery imaging with 64-slice spiral CT in atrial fibrillation patients: initial experience

    International Nuclear Information System (INIS)

    Zhou Xuhui; Yan Chaogui; Xie Hongbo; Li Xiangmin; Li Ziping; Meng Quanfei; Chen Xing

    2008-01-01

    Objective: To discuss the clinical value of coronary artery imaging using 64-slice spiral CT in patient with atrial fibrillation. Methods: The images of 31 patients with atrial fibrillation who underwent contrast-enhanced CT coronary angiography were evaluated. The presence of stenosis on each segment of coronary arteries was recorded and their degree of stenosis was measured using the vessel analysis software. Ten patients additionally underwent conventional coronary angiography. The results of conventional coronary angiography were compared with CT coronary angiography of the 10 patients. Results: Image reconstruction was based on absolute timing. The image quality of 364 coronary vessel segments on the images from 31 patients was evaluated and defined as excellent, fine, moderate or poor. The image quality was excellent, fine, moderate and poor in 85, 41, 5, and 8 vessel segments respectively in patient group with heart rate between 47 beat per minent (bpm) and 69 bpm; and in 63, 16, 13, and 15 vessel segments respectively in patent group with heart rate between 70 bpm and 79 bpm;and in 46, 25, 23, and 24 vessel segments in patient group with heart rate between 80 bpm and 105 bpm. There was significant difference among the three patient groups (H=22.08, P<0.01). Comparison was carried out between CT angiographic findings and conventional angiographic findings of the 125 segments of the coronary arteries in the 10 patients who underwent conventional coronary angiography. The sensitivity and specificity of CT angiography for diagnosing vessel with significant coronary stenosis (≥50% narrowing) was 85.0% (17/20) and 95.2% (100/105), respectively. Positive predictive value was 77.3% (17/22), and negative predictive value was 97.1% (100/103). Coronary CTA underestimated the lesions of 3 vessel segments and overestimated the lesions of 5 vessel segments. Conclusion: Coronary artery imaging with 64-slice row CT had clinical value for patients with atrial fibrillation

  16. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  17. [Diagnostic significance of multi-slice computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Liu, Fang; Tian, Zhi-Liang; Lei, Zi-Qiao; Li, You-Lin; Kong, Wei-Jia

    2005-04-01

    To evaluate the feasibility and usability of multi-slice computed tomography (MSCT) in congenital inner ear malformations. Fourty-four patients with sensorineural hearing loss (SNHL) were examined by a Somatom Sensation 16 (siemens, Germany) CT scanner with following parameters: 120 kV, 100 mAs, 0.75 mm collimation, 1 mm reconstruction increment, a pitch factor of 1 and a field of view of 100 mm. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment, and a field of view of 50 mm. The 3D reconstructions were done with volume rendering technique (VRT) on the workstation (3D Virtuoso and Wizard,siemens). Twenty-five patients were normal and 19 patients (36 ears) were congenital inner ear malformations among 44 patients scanned with MSCT. Of the malformations, all the axial, MPR and VRT images can display the site and degree in 33 ears. VRT images were superior to the axial images in displaying the malformations in 3 ears with the small lateral semicircular canal malformations. The malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity, 5 ears), vestibular and semicircular canal malformations( 14 ears), vestibular aqueduct dilate( 16 ears, of which 6 ears accompanied by other malformations), the internal auditory canal malformation(8 ears, all accompanied by other malformations). MSCT allows a comprehensively assessing various congenital ear malformations through high quality MPR and VRT reconstructions. VRT images can display the site and degree of the malformations three-dimensionally and intuitionisticly. It is very useful to the cochlear implantation.

  18. Preoperative assessment of gastric artery in patients with gastric cancer by CT angiography on 64-slice spiral CT

    International Nuclear Information System (INIS)

    Tang Lei; Zhang Xiaopeng; Sun Yingshi; Cao Kun; Qi Liping; Cui Yong; Wang Ning

    2010-01-01

    Objective: To evaluate the efficacy of different three-dimensional CTA methods on 64-slice sprial CT in the preoperative assessment of gastric arteries and their variations. Methods: Sixty-six consecutive patients with gastric cancer who underwent 64-slice spiral CT examinations preoperatively were retrospectively studied. To get the STS-MIP images, the thickness of slab was adjusted according to the inner diameter of targeted blood vessels and their cross-layer distribution. After four weeks, the AVVR images of all cases was got by the auto-vessel technique. The demonstration rates and origins of the direct and indirect feeding arteries were analyzed on AVVR and STS-MIP. McNemar tests were used to compare the detection rates of gastric feeding arteries by STS-MIP and AVVR. The relationship between CT value and display rate of vessels was analyzed using independent-samples t test. The variations of blood vessels were analyzed. Results: The display rate of indirect feeding arteries were all 100% (66/66) by STS-MIP and AVVR. The display rates of left gastric artery (LGA) and right gastroepiploic artery (RGEA) were 98.5% (65/66), 100.0% (66/66) and 97.0% (64/66), 100.0% (66/66) by STS-MIP and AVVR respectively. The display rates of right artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (PGA) by AVVR were lower than those of STS-MIP with statistical significances [RGA: 68.2% (45/66) vs. 98.5% (65/66), P<0.01; LGEA: 53.0% (35/66) vs. 97.0% (64/66), P<0.01; SGA: 7.6%(5/66) vs. 59.1% (39/66), P<0.01; PGA: 18.2% (12/66) vs. 63.6% (42/66), P<0.01]. The demonstration rates of LGEA, RGEA and SGA increased accompanied with the increasing of CT value in celiac axis (LGEA: 35 cases displayed with mean CT value of (272 ± 44) HU, 31 cases did not display with mean CT value of (229 ± 42) HU, t=4.043, P<0.01; RGEA: 64 cases

  19. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  20. The spiral CT manifestations of the blood supply of primary hepatocellular carcinoma: correlation with pathological findings

    International Nuclear Information System (INIS)

    Huang Juan; Zhou Xiangping; Liu Rongbo; Chen Xian; Xu Chongyong; Yan Zhihan; Xu Jianying

    2000-01-01

    Objective: To study the correlation between the CT features of tumor blood supplies and the pathological changes in primary hepatocellular carcinoma (PHCC). Methods: Fifty cases with surgically and pathologically proved PHCC underwent spiral CT scanning (plain + dual-phase). One research group blindly evaluated the CT films obtained. According to tumor contrast enhancement and signals showed on CT, the patterns of PHCC was divided into 4 types: arterial blood supplying, portal blood supplying, arterial combining with portal blood supplying, and poorly blood supplying. Microscopically, PHCC was respectively classified into grade I to IV with Edmonson's standard, and into 4 types (trabecular, pseudo-glandular, compact, scirrhous) with WHO histological grading standard. At last, the CT features of tumor blood supplies were correlated with pathologic changes. Results: 36(72%) cases were supplied by hepatic arterial blood, 6(12%) by arterial combining with portal blood supplying, 4(8%) by portal, and 4(8%) were poorly blood supplying. The patterns of tumor blood supplies in PHCC correlated with tumor cells differentiation (P<0.05). PHCC with better tumor cells differentiation was more associated with portal blood supplies. The patterns of tumor blood supplying in PHCC correlated with the histological type of the tumor cell (P < 0.05). All of the scirrhous PHCC were lack of blood supplies, the entire compact and most of the trabecular PHCC were supplied by a arterial blood. Conclusion: The most of PHCC were supplied by hepatic arterial blood and others were supplied by portal blood, arterial combining with portal blood or lack of blood supplies. Evaluation of tumor blood supplies in PHCC is considered to be useful in differential diagnosis and treatment of PHCC

  1. Use of spiral CT angiography to judge central pulmonary vascular involvement from lung cancer

    International Nuclear Information System (INIS)

    Tan Qunyou; Zhao Shaohong; Wang Fangze; Cai Zulong

    2000-01-01

    Objective: To evaluate the accuracy of spiral CT angiography (SCTA) in judging central pulmonary vascular involvement from lung cancer located in the hilum and correlate the resultant images with pathologic and surgical findings. Methods: SCTA was done in 33 patients who were preoperatively diagnosed as having lung carcinoma located in the hilum. Contrast medium was injected at a rate of 3 ml/sec with a power injector. The delay time was from 20 to 25 seconds. The pitch was 1 with 3 mm-collimation. Images of central pulmonary arteries and veins were reconstructed with shaded surface display (SSD), maximum intensity projection (MIP), curved planar reformation (CPR), and multi-planar reformation (MPR). Then the relation between tumor and vessels was assessed prospectively on both 3 mm interval axial CT and SCTA images with comparison to subsequent pathologic or surgical findings. Results: (1) In showing the integrity of central pulmonary arteries and veins, images reconstructed by different ways of SCTA had different strong and weak points. (2) The grading standard in this study, with which the relation between vessels and tumor was judged, reflected the basic and common characters of central pulmonary vascular involvement by tumor located in the hilum. compared with axial CT images, SCTA was more accurate in judging the relation between central pulmonary vessels and tumor, and the correlation of SCTA imaging features with pathological patterns and surgical findings was better than that of axial CT images, P < 0.05 and P < 0.0001, respectively. Conclusion: It was feasible to show the relation between central pulmonary vessel and lung cancer located in the hilum with SCTA. And the accuracy of judging the vascular involvement with SCTA was higher than that with axial CT

  2. Fuzzy-neural network in the automatic detection and volumetry of the spleen on spiral CT scans

    International Nuclear Information System (INIS)

    Heitmann, K.R.; Mainz Univ.; Rueckert, S.; Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Uthmann, T.

    2000-01-01

    Purpose: To assess spleen segmentation and volumetry in spiral CT scans with and without pathological changes of splenic tissue. Methods: The image analysis software HYBRIKON is based on region growing, self-organized neural nets, and fuzzy-anatomic rules. The neural nets were trained with spiral CT data from 10 patients, not used in the following evaluation on spiral CT scans from 19 patients. An experienced radiologist verified the results. The true positive and false positive areas were compared in terms to the areas marked by the radiologist. The results were compared with a standard thresholding method. Results: The neural nets achieved a higher accuracy than the thresholding method. Correlation coefficient of the fuzzy-neural nets: 0.99 (thresholding: 0.63). Mean true positive rate: 90% (thresholding: 75%), mean false positive rate: 5% (thresholding>100%). Pitfalls were caused by accessory spleens, extreme changes in the morphology (tumors, metastases, cysts), and parasplenic masses. Conclusions: Self-organizing neural nets combined with fuzzy rules are ready for use in the automatic detection and volumetry of the spleen in spiral CT scans. (orig.) [de

  3. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  4. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [Deutsch] Von Mai 1994 bis Oktober 1995 wurden

  5. Single-level dynamic spiral CT of hepatocellular carcinoma: correlation between imaging features and tumor angiogenesis

    International Nuclear Information System (INIS)

    Chen Weixia; Min Pengqiu; Song Bin; Xiao Bangliang; Liu Yan; Wang Wendong; Chen Xian; Xu Jianying

    2001-01-01

    Objective: To investigate the correlation of the enhancement imaging features of hepatocellular carcinoma (HCC) and relevant parameters revealed by single-level dynamic spiral CT scanning with tumor microvessel counting (MVC). Methods: The study included 26 histopathologically proven HCC patients. Target-slice dynamic scanning and portal venous phase scanning were performed for all patients. The time-density curves were generated with measurement of relevant parameters including: peak value (PV) and contrast enhancement ratio (CER), and the gross enhancement morphology analyzed. Histopathological slides were carefully prepared for the standard F8RA and VEGF immunohistochemical staining and tumor microvessel counting and calculation of VEGF expression percentage of tumor cells. The enhancement imaging features of HCC lesions were correlatively studied with tumor MVC and VEGF expression. Results: Peak value of HCC lesions were 7.9 to 75.2 HU, CER were 3.8% to 36.0%. MVC were 6 to 91, and the VEGF expression percentage were 32.1% to 78.3%. The PV and CER were significantly correlated with tumor tissue MVC (r = 0.508 and 0.423, P < 0.01 and 0.05 respectively). There were no correlations between PV and CER and VEGF expression percentage. Both the patterns of time-density curve and the gross enhancement morphology of HCC lesions were also correlated with tumor MVC, and reflected the distribution characteristics of tumor microvessels within HCC lesions. A close association was found between the likelihood of intrahepatic metastasis of HCC lesions with densely enhanced pseudo capsules and the presence of rich tumor microvessels within these pseudo capsules. Conclusion: The parameters and the enhancement imaging features of HCC lesions on target-slice dynamic scanning are correlated with tumor MVC, and can reflect the distribution characteristics of tumor microvessels within HCC lesions. Dynamic spiral CT scanning is a valuable means to assess the angiogenic activity and

  6. Evaluation of image quality and dose in renal colic: comparison of different spiral-CT protocols

    International Nuclear Information System (INIS)

    Rimondini, A.; Mucelli, R.P.; Dalla Palma, L.; De Denaro, M.; Bregant, P.

    2001-01-01

    The aim of this study was to test different technical spiral-CT parameters to obtain optimal image quality with reduced X-ray dose. Images were acquired with a spiral-CT system Philips Tomoscan AVE1, using 250 mA, 120 kV, and 1-s rotational time. Three protocols were tested: protocol A with 5-mm thickness, pitch 1.6, slice reconstruction every 2.5 mm; protocol B with 3-mm thickness, pitch 1.6, slice reconstruction every 1.5 mm; and protocol C with 3-mm thickness, pitch 2, slice reconstruction every 1.5 mm. Two phantoms were employed to evaluate the image quality. Axial images were acquired, then sagittal and coronal images were reconstructed. Finally, the absorbed X-ray dose for each protocol was measured. Regarding image quality, 5-mm-thick images (protocol A) showed greater spatial resolution and lower noise compared with 3-mm-thick images (protocols B and C) on the axial plane; 3-mm reconstructed sagittal and coronal images (protocols B and C) showed an improved image quality compared with 5-mm reformatted images (protocol A). Concerning X-ray dose, the mean dose was: protocol A 19.6±0.8 mGy; protocol B 14.4±0.6 mGy; protocol C 12.5±1.0 mGy. Our study supports the use of thin slices (3 mm) combined with pitch of 1.6 or 2 in renal colic for X-ray dose reduction to the patient and good image quality. (orig.)

  7. Thin-section spiral CT evaluation of morphologic effects of aging lung in asymptomatic adult subjects

    International Nuclear Information System (INIS)

    Li Kuncheng; Liu Jian; Yang Yanhui; Yao Xinyu; Yin Jianguo; Wang Shiwen; He Zuoxiang

    2006-01-01

    Objective: To evaluate the imaging signs of aging lung in asymptomatic adult subjects by using thin-section spiral CT, and analyze the correlation between the signs and the age of examined cases, as well as probe their clinical application value. Methods: One hundred and six healthy adult subjects were divided into 3 groups: 30 to 44 years (n=31), 45 to 59 years (n=30), and over 60 years (n=45), and all the subjects underwent thin-section spiral CT scans in the upper lung field, the middle lung field and the lower lung field. The evaluation indices included the lung interstitium changes, emphysematous changes, mosaic perfusion, dependent density difference, and pleural thickenning. According to the relative score standard, the above-mentioned indices were totally calculated and converted into the score value. The data were statistically processed with SPSS for Windows. Results: Among the three groups, there were remarkable differences in the indices including the lung interstitium changes, emphysematous changes, and mosaic perfusion, respectively (χ 2 =8.10, 9.73, 15.54, P 2 =3.66, 3.24, P> 0.05). The score values had a significant positive correlation with the age (r=0.709, P<0.01). Conclusion: The signs including the lung interstitium changes, emphysematous changes, mosaic perfusion, the dependent density difference, and pleural thickenning can be found in asymptomatic subjects, and they become prominent as the age increases. HRCT is one of the most important methods for evaluating the early signs of the senile lung. (authors)

  8. Correlation study of multislice spiral CT and pathology in relationship between solitary pulmonary nodule and bronchus

    International Nuclear Information System (INIS)

    Qiang Jinwei; Ye Xuanguang; Zhou Kangrong; Jiang Yaping; Wang Qun; Xu Songtao; Tan Lijie

    2003-01-01

    Objective: To investigate the relationship between solitary pulmonary nodule (SPN) and bronchus and its value in predicting the nature of nodule. Methods: Continuous volume targeted scans of 0.5 mm collimation were prospectively performed with multislice spiral CT (MSCT) and reconstructed images of MPR, CPR, and SSD in workstation in 75 patients of SPN with ≤3 cm in diameter were acquired. The emphasis was paid on the manifestation of the shapes and patterns of SPN with related bronchi. The results were correlated with macroscopic and microscopic specimens. Results: (1) The SPN-bronchus relationship was shown very clearly in all patients by the designed protocol. CT demonstrated the relations between SPN and bronchus in 44 (86.3%) malignant and 16 (66.7%) benign nodules. There was no statistically significant difference (P=0.065). (2) Five types of SPN-bronchus relationship were identified with MSCT. Type I: bronchus was obstructed abruptly by the SPN, type II: bronchus penetrated into SPN with tapered narrow and interruption, type III: bronchus lumen shown within SPN was patent and intact, type IV: bronchus ran at the periphery of SPN with intact lumen, and type V: bronchus was displaced, compressed, and narrowed by SPN. (3) With respect to the nature of SPN, malignant nodule most commonly showed type I, secondly type IV, and rarely type V. Benign nodule most often showed type V, secondly type I, and no type II. With respect to the pattern, type I, II, and IV patterns were more commonly seen in malignant nodule, whereas type V pattern was seen frequently in benign nodule. Type III pattern was slightly more common in benign cases. Conclusion: Spiral targeted scan of ultra-thin section with MSCT and followed by MPR, CPR, and SSD reconstruction can greatly improve the manifestation of the bronchioles and accurately demonstrate the patterns of SPN-bronchus relationship. Varied patterns are corresponding to certain nodule and reflect definite pathologic changes

  9. Spiral hydro-CT of the pancreas in the thin-slice method

    International Nuclear Information System (INIS)

    Richter, G.M.; Simon, C.; Hoffmann, V.; DeBernardinis, M.; Seelos, R.; Senninger, N.; Kauffmann, G.W.

    1996-01-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [de

  10. Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot

    International Nuclear Information System (INIS)

    Wang Ximing; Wu Lebin; Sun Cong; Liu Cheng; Chao, Bao-Ting; Han Bo; Zhang Yunting; Chen Haisong; Li Zhenjia

    2007-01-01

    Objective: To explore the clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Methods: Eighteen patients with diagnosed Tetralogy of Fallot underwent cardiac CT angiography with 64-slice CT (CTA). Two- and three-dimensional images were used for diagnosing in all cases by means of MPR (coronal, sagital and oblique), cMPR, MIP and VRT. Results: All patients had ventricular septal defect, pulmonary stenosis and hypertrophy of right ventricle. The morphologic features of Tetralogy of Fallot were equal to echocardiography. Patent ductus arteriosus (PDA) were detected on eight patients. Main coronary artery branches and partial sub-branches were visualized in all patients. Abnormal coronary arteries were found in seven cases: both left and right main coronary artery arising from the right aortic sinus one case, right main coronary artery and circumflex (CX) arising from the right aortic sinus one case, left anterior descending (LAD) and CX arising from left aortic sinus directly one case, left and right coronary artery arising from back and front of the aortic sinus, respectively, three cases. Pulmonary artery branch stenosis was found in 12 cases and branch pulmonary artery dilation noticed in 1 case. Double superior vena cava was also found in one case. According to the surgery the diagnostic accuracy of CT and Echocardiography was 95.45 and 83.33%, respectively. Conclusion: Two- and three-dimensional 64-slice CTA not only show the overall anatomical structure of the heart, but also show coronary and pulmonary arteries. With these results, evaluation of coronary anomalies and pulmonary artery stenosis with 64-MSCT is extremely valuable for planning the operative procedure on the patients with Tetralogy of Fallot

  11. Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Wang Ximing [Tianjin Medical University, Tianjin City (China) and Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China)], E-mail: wxming369@163.com.cn; Wu Lebin [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Sun Cong [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Shandong University Medical College, Shandong Jinan 250012 (China); Liu Cheng [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Chao, Bao-Ting [Shandong University Medical College, Shandong Jinan 250012 (China); Han Bo [Shandong Provincial Hospital Pediatric Department, Shandong, Jinan 250021 (China); Zhang Yunting [Tianjin Medical University, General Hospital MR Department, Tianjin City (China); Chen Haisong [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Shandong University Medical College, Shandong Jinan 250012 (China); Li Zhenjia [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China)

    2007-11-15

    Objective: To explore the clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Methods: Eighteen patients with diagnosed Tetralogy of Fallot underwent cardiac CT angiography with 64-slice CT (CTA). Two- and three-dimensional images were used for diagnosing in all cases by means of MPR (coronal, sagital and oblique), cMPR, MIP and VRT. Results: All patients had ventricular septal defect, pulmonary stenosis and hypertrophy of right ventricle. The morphologic features of Tetralogy of Fallot were equal to echocardiography. Patent ductus arteriosus (PDA) were detected on eight patients. Main coronary artery branches and partial sub-branches were visualized in all patients. Abnormal coronary arteries were found in seven cases: both left and right main coronary artery arising from the right aortic sinus one case, right main coronary artery and circumflex (CX) arising from the right aortic sinus one case, left anterior descending (LAD) and CX arising from left aortic sinus directly one case, left and right coronary artery arising from back and front of the aortic sinus, respectively, three cases. Pulmonary artery branch stenosis was found in 12 cases and branch pulmonary artery dilation noticed in 1 case. Double superior vena cava was also found in one case. According to the surgery the diagnostic accuracy of CT and Echocardiography was 95.45 and 83.33%, respectively. Conclusion: Two- and three-dimensional 64-slice CTA not only show the overall anatomical structure of the heart, but also show coronary and pulmonary arteries. With these results, evaluation of coronary anomalies and pulmonary artery stenosis with 64-MSCT is extremely valuable for planning the operative procedure on the patients with Tetralogy of Fallot.

  12. The value of multislice spiral CT in transcatheter arterial chemoembolization of the hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Li Zhigang; Zhao Junjing; Shi Gaofeng; Li Shunzong; Han Pengyin; Yang Guang; Liang Guoqing; Wang Hongguang; Huang Jingxiang

    2006-01-01

    Objective: To evaluate the value of multislice spiral CT (MSCT) in transcatheter arterial chemoembolization of the hepatocellular carcinoma. Methods: MSCT were performed in 54 cases of HCC before interventional procedure. CT findings of hepatic artery phase, portal venous phase and hepatic venous phase were observed respectively. CTA were done in 12 cases, the anatomy of celiac artery and its branches were observed. The schemes of interventional therapy were worked out according to the findings of MSCT. The demonstration of lesions and its complications were compared between CT and DSA. Reconstruction of celiac artery branches used the technique of VRT, MIP or MPR. Results: MSCT showed 225 lesions, 10 cases tumor thrombosis of portal vein, 1 case hepatic arteriovenous shunt, and 13 cases hepatic arterioportal shunt. Positive rate of MSCT in showing number of tumor lesions, tumor thrombosis in portal vein was slightly higher than that of DSA, but there was no significant difference (P>0.05). Showing of 3D reconstruction of celiac artery branches in CTA is better than that in DSA, Showing of angles between celiac artery and abdominal aorta in MSCT is more convenient than that in DSA. MSCT showed 5 cases hepatic artery original abnormality. The results were in accord with that in DSA. Five cases were demonstrated of multiple supply blood vessels of tumor in MSCT, It was slightly lower than that of DSA. Conclusion: MSCT is of importance for guidance of transcatheter arterial chemoembolization of the hepatocellular carcinoma, delay time of CT scan is the key to the showing of lesions and blood vessels. (authors)

  13. The experimental study on bowel ischemia in closed loop obstruction by using multi-phase spiral CT

    International Nuclear Information System (INIS)

    Zhang Xiaoming; Yang Hanfeng; Huang Xiaohua; Tang Xianying; Jian Pu; Yang Zhengwei; Zhou Jiyong; Zhao Zongwen

    2005-01-01

    Objective: To evaluate the bowel ischemia in experimental closed loop obstruction by using multi-phase spiral CT. Methods: Twenty-four New Zealand rabbits of both sexes (mean age, 4 months, and mean body weight, 2.5-3.0 kg) were divided randomly into three groups with each group containing 8 rabbits. After clamping 10-15 cm segments of small bowel and their veins for 0.5 hours (Group A), 1-2 hours (Group B), and 3-5 hours (Group C), respectively, multi-phase spiral CT was performed at baseline, and at arterial, venous, and delayed phases after intravenous contrast administration. Then the rabbits were sacrificed to observe their surgical and histological changes. Two radiologists, blinded to the animal model classification and their histological results, individually reviewed the CT images to observe the CT appearances of the closed loop. Statistical significance criteria was determined by P 0.05) at baseline, however, they were significantly different (P<0.05) at all phases after enhancement. Among rabbits without necrotic closed loop, 11 of 13 had continuous enhancement at all phases, while only 1 of 11 rabbits with necrotic closed loop showed continuous enhancement (P<0.05). Conclusion: The ischemia of bowel wall in different phases after clamping small bowel and their veins can be evaluated by using enhanced multi-phase spiral CT. Continuous enhancement of bowel wall in multi-phase spiral CT can be seen prominently in the early bowel ischemia, but necrotic bowel shows no enhancement. (authors)

  14. Effect of the degree of sternal depression on the cardiac rotation in pectus excavatum: evaluation with spiral CT

    International Nuclear Information System (INIS)

    Yu Jianqun; Yang Zhigang; Li Zhenlin; Guo Yingkun; Lu Chunyan; Zhang Mei

    2004-01-01

    Objective: To evaluate the effects of the degree of sternal depression on the cardiac rotation in pectus excavatum by using spiral CT. Methods: Spiral CT features of 32 patients with surgically corrected pectus excavatum were retrospectively reviewed. They included 27 males and 5 females ranging in age from 6 months to 17 years (mean, 6.3 years). Analysis was based on relationship among the degree of sternal depression, CT depression index, cardiac rotation angle, and PV angle. Results: 32 cases of pectus excavatum presented the sternal depression (21 ± 7) mm, CT depression index 2.9 ± 1.8, cardiac rotation angle (55.9 ± 9.8) degree, and PV angle (49.8 ± 14.0) degree, respectively. The sternal depression (17 mm) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (21 mm) and CT depression index larger than 2.9 (27 mm) (F 5.39, P<0.01). Cardiac rotation angle (49.7 degree) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (55.5 degree) and CT depression index larger than 2.9 (66.9 degree) (F=7.44, P<0.01). PV angle (58.7 degree) in cases with CT depression index less than 2.4 was larger than those with CT depression index 2.4-2.9 (46.5 degree) and CT depression index more than 2.9 (42.4 degree) ( F=3.33, P<0.05). Cardiac rotation angle of pectus excavatum had positive correlation with the CT depression index (γ=0.73, P<0.01). Conclusion: Spiral CT is a better tool for revealing chest deformity and corresponding cardiac rotation. The degree of sternal depression in pectus excavatum directly influences the cardiac rotation, and they had positive correlation. (authors)

  15. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT

    International Nuclear Information System (INIS)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W.; Koester, M.

    1999-01-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [de

  16. Blind deblurring of spiral CT images - comparative studies on edge-to-noise ratios

    International Nuclear Information System (INIS)

    Jiang Ming; Wan Ge; Skinner, Margaret W.; Rubinstein, Jay T.; Vannier, Michael W.

    2002-01-01

    A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the phantom study, it is shown that all the ratios share similar properties, validating the blind deblurring algorithm. The image fidelity improvement varies from 29% to 33% for different ratios, according to the root mean square error (RMSE) criterion; the optimal iteration number determined for each ratio varies from 25 to 35. Those ratios that are associated with most satisfactory performance are singled out for the image fidelity improvement of about 33% in the numerical simulation. After automatic blind deblurring with the selected ratios, the spatial resolution of CT is substantially refined in all the cases tested

  17. Measurement and analysis of cardiopulmonary vascular in Lanzhou healthy adults with multislice spiral CT

    International Nuclear Information System (INIS)

    Shi Xiaonan; Guo Shunlin

    2013-01-01

    Objective: To constitute a normal standard of cardiopulmonary vascular diameter and size of normal adult in Lanzhou, and to compared with the other's data reported in the previous bibliography by measuring diameter and area of cardiopulmonary artery lumen of the healthy adults in Lanzhou with multislice spiral CT (MSCT). Methods: Three hundred Lanzhou adults with no cardiopulmonary disease were equally assigned to 3 groups according to their age (A group: 18-39 years, B group: 40-60 years, C group: 61-80 years; 50 females and 50 males in each group). CT data were acquired at the end of deep inspiration phase and measurements were done on 3D reconstruction image with precise landmarks. All the results were statistically analyzed. Results: The diameters and areas of the main pulmonary artery left pulmonary artery right pulmonary artery ascending aorta and descending aorta differed significantly among the 3 groups (P<0.05). In groups B and C, there were significant differences in diameters and areas of pulmonary artery left pulmonary artery and right pulmonary between different genders (P<0.05). Conclusion: Imaging standard is provided for Lanzhou adult in early diagnosis of cardiopulmonary disease. The diameters and areas of main pulmonary artery left pulmonary artery and right pulmonary artery of Lanzhou healthy adults are different from that of other regions. It may be related to the geographical environment and the state of air pollution in Lanzhou. (authors)

  18. Radiation dosimetry and its influencing factors for the multi-detector/slice spiral CT

    International Nuclear Information System (INIS)

    Bai Mei; Zheng Junzheng

    2008-01-01

    The Multi-Detector/Slice Spiral Computed Tomography (MDCT/MSCT)reflects the new progress in equipment and technology for radiology. Its popularized application demonstrates its advantages for clinical diagnosis. With the continuous development and growing uses of the MDCT/MSCT, the medical exposure of the patients and public has also been increasing. Therefore, assessment of the radiation dose and radiation risk from X-CT has become an increasingly important concern that should be addressed. Thus, this paper summarizes the main characteristics of the MDCT/MSCT emphasizing particularly on the radiation dosimetry, and reviews the expressions and measures of radiation dose in the MDCT/MSCT. In addition, main factors that influence radiation dose from the MDCT/MSCT are also discussed. A proper grasp of its radiation dosimetry and assessment method can significantly help radiologists, health physicists, medical physicists, X-CT engineers and manufacturers improve the management of radiation dose while optimizing the image quality in the MDCT/MSCT. (authors)

  19. TRIPLE PHASE SPIRAL C.T. IN THE EVALUATION OF HEPATIC MASSES

    Directory of Open Access Journals (Sweden)

    Prasad

    2015-10-01

    Full Text Available BACKGROUND AND OBJECTIVE : The goal of the study is to determine the value of various phases of Triple, Helical CT, Hepatic arterial Phase (HAP, Portal venous phase (PVP and Equilibrium Phase (EP, is the detection and characterization of Hepatic Lesions and to evaluate whether u nenhanced and hepatic arterial phases when used in conjunction with porto venous phase would lead to detection of greater number of lesions or better characterization of lesion. METHODOLOGY : The study population consists of 50 Patients aged between 30 Years and 80 Years were examined with multiphase (plain, hepatic arterial, portal venous and equilibrium phases. Spiral CT of liver. Patients were referred for CT scan when liver diseases were suspected clinically, if ultrasound and other previous investi gations revealed lesions which had to be further evaluated by spiral CT and to detect liver metastases in known cases of primary extra hepatic malignancy. CT TECHNIQUE: Helical scanning of liver with Toshiba astein s4, continuous spiral run and the images were reconstructed at 5mm intervals. Contrast material 100ml was injected through 18 or 20G catheter at the rate of 3ml per second using automatic medrad power injector. Non - ionic contrast [IOHEXOl – 300mg perml was used in all the patients]. After obtaine d unenhanced CT scan HAP scanning was initiated 25 seconds after initiation of contrast injection. Portal venous phase scanning was initiated 60 - 65 seconds after start of contrast injection. Equilibrium phase scanning was initiated after 180 seconds after the start of contrast injection. IMAGE EVALUATION: All the images of 4 phases were reviewed. First Step : The presence, appearance and enhancement of each Lesion were noted in all phases and lesion were described Isodense, Hypodense Hyperdense based on thei r attenuation relative to liver parenchyma during that phase of scanning. Based on enhancement pattern of the lesion during various phases they were

  20. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  1. Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

    International Nuclear Information System (INIS)

    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J.-J.; Hou, X.-L.; Yang, X.-B.; Chen, J.-H.; Chen, Y.-D.

    2013-01-01

    Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as “non-assessable”. The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

  2. Clinical application of 16-slice spiral CT in reconstruction imaging of coronary artery for diagnosing coronary disense

    International Nuclear Information System (INIS)

    Mao Xinbo; Zhu Xinjin; Zeng Huiliang; Chen Xueguang

    2005-01-01

    Objective: An evaluation of the reconstructed imaging of coronary arteries with 16-slice spiral CT in diagnosis of coronary disease. Methods: The reconstructed images of coronary arteries obtained on a 16-slice spiral CT scanner were reviewed in 60 cases, on which the following techniques were applied: retrospective ECG-gating, Segment method with 75% R-R interval, volume rendering technique (VRT), maximum intensity projection (MIP), mulfiplanar reconstruction (MPR), curved planar reconstruction (CPR) and CT virtual endoscopy (CTVE). Results: In all 60 cases, different stages of CHD were revealed in 21 cases; none abnormality was found in 33; and images were in poor quality in 2 cases, which was available for diagnosis. There were 4 stents planted in 4 cases: soft plaque suspected in lcase, patent in 2 and occlude in 1. Conclusion: The reconstructed imaging of coronary arteries with 16-slice spiral CT is superior modality in evaluation of severe coronary stenosis, plaques, and the pantency of the intra-luminal stents, which is an efficient and non-invasive imaging in diagnosis of early-stage CHD and screening in high risk population. (authors)

  3. MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis

    International Nuclear Information System (INIS)

    Berg, B.C. vande; Lecouvet, F.E.; Maldague, B.; Malghem, J.

    2004-01-01

    The aim of this study was to determine signal intensity patterns of cartilage defects at MR imaging. The MR imaging (3-mm-thick fat-suppressed intermediate-weighted fast spin-echo images) was obtained in 31 knees (21 male and 10 female patients; mean age 45.5 years) blindly selected from a series of 252 consecutive knees investigated by dual-detector spiral CT arthrography. Two radiologists determined in consensus the MR signal intensity of the cartilage areas where cartilage defects had been demonstrated on the corresponding reformatted CT arthrographic images. There were 83 cartilage defects at spiral CT arthrography. In 52 (63%) lesion areas, the MR signal intensity was higher than that of adjacent normal cartilage with signal intensity equivalent to (n=31) or lower than (n=21) that of articular fluid. The MR signal intensity was equivalent to that of adjacent normal cartilage in 17 (20%) lesion areas and lower than that of adjacent cartilage in 8 (10%) lesion areas. In 6 (7%) lesion areas, mixed low and high signal intensity was observed. The MR signal intensity of cartilage defects demonstrated on spiral CT arthrographic images varies from low to high on fat-suppressed intermediate-weighted fast spin-echo MR images obtained with our equipment and MR parameters. (orig.)

  4. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  5. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes.

  6. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    International Nuclear Information System (INIS)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes

  7. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  8. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  9. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT

    International Nuclear Information System (INIS)

    Vembar, M.; Garcia, M.J.; Heuscher, D.J.; Haberl, R.; Matthews, D.; Boehme, G.E.; Greenberg, N.L.

    2003-01-01

    In this investigation, we describe a quantitative technique to measure coronary motion, which can be correlated with cardiac image quality using multislice computed tomography (MSCT) scanners. MSCT scanners, with subsecond scanning, thin-slice imaging (sub-millimeter) and volume scanning capabilities have paved the way for new clinical applications like noninvasive cardiac imaging. ECG-gated spiral CT using MSCT scanners has made it possible to scan the entire heart in a single breath-hold. The continuous data acquisition makes it possible for multiple phases to be reconstructed from a cardiac cycle. We measure the position and three-dimensional velocities of well-known landmarks along the proximal, mid, and distal regions of the major coronary arteries [left main (LM), left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX)] during the cardiac cycle. A dynamic model (called the 'delay algorithm') is described which enables us to capture the same physiological phase or 'state' of the anatomy during the cardiac cycle as the instantaneous heart rate varies during the spiral scan. The coronary arteries are reconstructed from data obtained during different physiological cardiac phases and we correlate image quality of different parts of the coronary anatomy with phases at which minimum velocities occur. The motion characteristics varied depending on the artery, with the highest motion being observed for RCA. The phases with the lowest mean velocities provided the best visualization. Though more than one phase of relative minimum velocity was observed for each artery, the most consistent image quality was observed during mid-diastole ('diastasis') of the cardiac cycle and was judged to be superior to other reconstructed phases in 92% of the cases. In the process, we also investigated correlation between cardiac arterial states and other measures of motion, such as the left ventricular volume during a cardiac cycle, which earlier has been

  10. Shallow and deep breath lung tumor volume as estimated by spiral volumetric CT in comparison to standard axial CT using virtual simulation

    International Nuclear Information System (INIS)

    Quader, M.A.; Kalend, A.M.; Deutsch, M.; Greenberger, J.S.

    1995-01-01

    Purpose/Objective: In order to assess an individual patient tumor volume (TV) margins that are sufficient to design a beam-eye-view (BEW) conformal portal, the radiographic extent of gross tumor volume (GTV) dimensions and its fluctuation with breathing are measured by fast spiral CT scanning of patients treated for Stage II, III lung cancers using 5-6 field multi-collimated conformal beams. Materials and Methods: Over the course of conformal radiotherapy for lung cancer, a full thorax CT scans of the patient were taken by conventional axial CT scanning with patients immobilized in the treatment position and breathing normally. Patient(s) with good pulmonary function test (PFT) status were selected to perform deep breathing and re-scanned by fast spiral techniques in order to re-acquire the tomographic variation in the (GTV) with breathing. A Picker spiral ZAP-100 software running on the AQSim-PQ-2000 was used with a variable helical pitch of 1.0, 1.5 and 2.0. The variable pitch spirals were limited to tumor bed, diaphragm and lung apex area for measurements. Effect of breathing motion along x,y,z direction were then assessed for each beam-eye-view portal as seen in digitally reconstructed radiography (DRR) at the treated gantry angle. Results: Comparison of axial and spiral scans shows the progression of lung and diaphram motion with breathing can be gauged better in spiral scans. The movement of the diaphragm during shallow breathing has been found to be 2-3cm by measuring the distance between the most inferior and superior slices where diaphragm is present. The variation of the tumor dimensions along AP/PA and lateral direction seems to be less sensitive to breathing than those along inferior-superior direction. Conclusion: The fast spiral CT scanning is sensitive to patient lung motion and can be used to determine the fluctuations of the gross tumor volume with breathing. The extent of the fluctuation is location dependent and increases as one moves from the

  11. A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window

    International Nuclear Information System (INIS)

    Yu Hengyong; Ye Yangbo; Zhao Shiying; Wang Ge

    2005-01-01

    For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be applied for n-PI-window-based reconstruction in the nonstandard spiral scanning case. In this paper, we design an n-PI-window-based BPF algorithm, and report the numerical simulation results with the 3D Shepp-Logan phantom and Defrise disk phantom. The proposed BPF algorithm consists of three steps: cone-beam data differentiation, weighted backprojection and inverse Hilbert filtration. Our simulated results demonstrate the feasibility and merits of the proposed algorithm

  12. Recurrent pyogenic cholangitis: clinico-pathologic correlation of focal attenuation differences on multi-phasic spiral CT

    International Nuclear Information System (INIS)

    Jeong, Jun Yong; Han, Joon Koo; Kim, Tae Kyoung; Kim, Seog Joon; Kim, Hyun Bum; Choi, Byung Ihn

    2002-01-01

    To determine the clinical and the pathologic significance of the focal attenuation differences (FAD) and bile duct wall enhancement occurring in recurrent pyogenic cholangitis (RPC) and seen at multiphasic spiral CT. Among the multiphasic (non-contrast, arterial and portal or delayed phase) spiral CT findings of 60 consecutive patients, two types of FAD were noted during the non-contrast phase. These were Type A (iso) and Type B (low attenuation), and their distribution pattern (lobar versus patchy, multifocal) and the and the presence or absence of bile duct wall enhancement were recorded. The radiologic findings were correlated with the clinical and pathologic findings. Two types of FAD were noted in 40 of the 60 patients. Active in flammation was present in 19 of the 27 with Type-A and in ten of the 15 in whom the presence of RPC was pathologically proven. Ten of the 13 with Type-B FAD were in a subclinical state, and nine of the ten in whom RPC was pathologically proven had chronic inflammation. Among 20 patients who did not have FAD, RPC was subclinical in 18 and dormant in nine of the eleven in whom its presence was pathologically proven (p<0.001). Clinico-pathologic correlation with bile duct wall enhancement and the distribution pattern of FAD showed no statistical significance. The inflammatory activity of RPC can be predicted by analysis of the FAD seen at multiphasic spiral CT

  13. Assessment of hemodynamics in a rat model of liver cirrhosis with precancerous lesions using multislice spiral CT perfusion imaging.

    Science.gov (United States)

    Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng

    2013-01-01

    To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.

  14. The postprocessing techniques in renal artery reconstructions and clinical application with multidetector spiral CT angiography

    International Nuclear Information System (INIS)

    Yu Yuanxin; Liang Changhong; Zhang Zhonglin; Xie Shufei; Liu Yubao; Tang Xiangzhou

    2005-01-01

    Objective: To investigate the value and predominance for imaging postprocessing techniques of renal artery variation and lesions by multidetector spiral CT angiography. Methods: 51 patients with renal artery disease including 12 artery variation, 27 artery stenosis, 3 renal anenrysm, 3 thrombosis of renal artery and 3 dissecting aneurysm of renal artery by SSD, MIP and CPR were enrolled. The effectiveness of these imaging postprocessing methods was compared, 29 of them were confirmed by DSA and 3 by operation, others were checked by MRA and follow up. Results: All abnormalities and diseases were cleariy displayed. The specificity and sensitivity were 100% respectively. In the all imaging postprocessing techniques, MPR can clearly display the calcification of the arteries, stenosis, embolism, aneurysm but do not display the anatomy satisfactorily. MIP can not only clearly display the anatomy but display the different configurations. VR can display the artery figures but can not display the information of lumen of blood vessels. SSD can display the complex vessel anatomy but it was influenced by its threshold selection. CPR can spread and display directly the tortuous renal artery and measure the section area of stenosis. Conclusions: MSCTA is helpful to accurately display the renal artery variation and lesions. Both MIP and VR are the best choice to illustrate the renal artery abnormalities. And MPR and SSD are assistant in the diagnosis of' renal artery lesions. (authors)

  15. Spiral CT aortography: an efficient technique for the diagnosis of traumatic aortic injury

    International Nuclear Information System (INIS)

    Wicky, S.; Capasso, P.; Meuli, R.; Schnyder, P.; Fischer, A.; Segesser, L. von

    1998-01-01

    The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients. (orig.)

  16. Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

    International Nuclear Information System (INIS)

    Greess, H.; Lutze, J.; Noemayr, A.; Bautz, W.; Wolf, H.; Hothorn, T.; Kalender, W.A.

    2004-01-01

    The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as ''very good,'' ''good,'' ''diagnostic'' and ''poor'' in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. (orig.)

  17. Prevalence of emphysematous changes as shown by low-dose spiral CT screening images in 6144 healthy subjects

    International Nuclear Information System (INIS)

    Nawa, Takeshi

    2002-01-01

    We assessed the prevalence of emphysematous changes among healthy workers and retired persons, using subjective evaluations of low-dose spiral CT images obtained during thoracic CT screenings for lung cancer. Among 6144 male participants (50-69 years old; mean age, 57), we detected 686 cases (11.2%) with emphysematous changes. The majority (95.3%) of CT-detected emphysema cases were in current or former smokers, and 169 cases (24.6%) showed significant obstructive impairment. Of 236 cases with emphysematous changes in the internal region (more than 20 mm from the costal margin), 98 (41.5%) had significant obstructive impairment. Smoking was found to be the major risk factor for CT-detected emphysema. Longitudinal observation of the emphysema cases, as well as health care support for cessation of smoking, is very important. (author)

  18. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  19. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  20. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    International Nuclear Information System (INIS)

    Sabharwal, Rohan; Vladica, Philip; Coleman, Patrick

    2007-01-01

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  1. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system

    International Nuclear Information System (INIS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2002-01-01

    The aim of this study was to evaluate a computer-aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Eighty-eight consecutive spiral-CT examinations were reported by two radiologists in consensus. All examinations were reviewed using a CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm is designed to detect nodules with diameters of at least 5 mm. A total of 153 nodules were detected with at least one modality (radiologists in consensus, CAD, 85 nodules with diameter <5 mm, 68 with diameter ≥5 mm). The results of automatic nodule detection were compared to nodules detected with any modality as gold standard. Computer-aided diagnosis correctly identified 26 of 59 (38%) nodules with diameters ≥5 mm detected by visual assessment by the radiologists; of these, CAD detected 44% (24 of 54) nodules without pleural contact. In addition, 12 nodules ≥5 mm were detected which were not mentioned in the radiologist's report but represented real nodules. Sensitivity for detection of nodules ≥5 mm was 85% (58 of 68) for radiologists and 38% (26 of 68) for CAD. There were 5.8±3.6 false-positive results of CAD per CT study. Computer-aided diagnosis improves detection of pulmonary nodules at spiral CT and is a valuable second opinion in a clinical setting for lung cancer screening despite of its still limited sensitivity. (orig.)

  2. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  3. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT; Fruehes klinisches Management nach Polytrauma mit 1- und 4-Schicht-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kloeppel, R.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schreiter, D. [Chirurgische Intensivtherapieabteilung, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany); Dietrich, J. [Abt. Neuroradiologie der Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Josten, C. [Klinik und Poliklinik fuer Unfall- und Wiederherstellungschirurgie, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany)

    2002-07-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of {approx}30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by {approx}4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [German] Die klinische Erstversorgung Polytraumatisierter schliesst inzwischen in vielen Unfallkliniken den fruehzeitigen Einsatz der Spiral-CT ein. Kann die neuerlich eingefuehrte Mehrschicht-Spiral-CT Ergebnisse und Patientenmanagement weiter verbessern?Nach lebensrettenden Sofortmassnahmen, Thoraxroentgen und Notsonographie im Schockraum erfolgte die CT: Von 1998-2000 wurden 241 Patienten mit einem 1-Schicht-Spiral-CT (Somatom plus 4) und in 2001 79 Patienten mit einem 4-Schicht-Spiral-CT (Somatom VZ, beide Siemens Med. Sol.) untersucht. Klinisch ausgewaehlte Extremitaetenaufnahmen wurden ergaenzt.359 von 360 Untersuchungen verliefen erfolgreich

  4. Classification of fractures of the distal r[ius - Comparative evaluation of spiral CT images and X-rays

    International Nuclear Information System (INIS)

    Roehnert, W.; Nitzsche, H.; Franck, W.M.; Amlang, M.

    1998-01-01

    Within the framework of a prospective study 35 patients with fractures of the distal r[ius safely diagnosed to require surgery have been [ditionally scanned by spiral CT. For more exact diagnostic evaluation of the joint surfaces and the fractures, multiplane reconstructions have been m[e to enhance the information obtained from the primary, axial tomographic images. Two experts independently performed classification on the basis of the X-rays and the CT scans, applying the AO scheme and the method of Frykman. Classifications according to the AO scheme were found to agree for only 28.6 % of the patients, which means that 57.1 % of the fractures shown by the X-rays were more or less underassessed. Classification according to Frykman's method revealed fewer deviations and agreement in 51.4 % of the cases. Biplanar r[iography continues to be considered as the standard method for examination of distal r[ius fractures, but it is recommended to perform spiral CT scans for evaluation of more complex distal r[ius fractures because these may require different therapies according to fracture types. (orig./CB) [de

  5. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  6. A multi-slice gradient sequence for contrast enhanced MR diagnosis of intracranial tumours

    International Nuclear Information System (INIS)

    Schoerner, W.; Sander, B.; Kornmesser, W.; Laniado, M.; Nakamura, T.; Felix, R.

    1988-01-01

    A multi-slice gradient echo sequence (FLASH) was compared with a conventional spin-echo (SE) technique with regard to its value for contrast enhanced MR diagnosis. In 28 patients with cerebral tumours, SE images (SE 400/30; four images/3.4 minutes) and FLASH images (FLASH 315/14; 15 images/1.4 minutes) were obtained before and after gadolinium DTPA. After gadolinium-DTPA results were comparable for both techniques with respect to contrast enhancement, tumor contrast and delineation. Because of the higher efficiency of the FLASH 315/14 technique, this sequence is the method of choice for contrast enhanced cerebral MR imaging. (orig.) [de

  7. Diagnosis of multidetector spiral CT and its reconstruction techniques in trachea and principal bronchus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Luo; Hong, Shan; Zaibo, Jiang; Lufang, Li; Jiansheng, Zhang [Zhongshan Univ., Guangzhou (China). The Third Univ. Hospital, Dept. of Radiology; Lijia, Gu; Shaohong, Huang; Yi, Jin; Zhiqiang, Hou

    2003-12-01

    Objective: To investigate the clinical diagnostic value of multidetector spiral CT (MSCT) and its reconstruction techniques including multiplanar volume reformation (MPVR), volume rendering (VR), and virtual bronchoscopy (VB) in the trachea and principal bronchus tumors. Methods: Thin slice MSCT scanning was performed in 31 patients with suspected trachea or principal bronchus tumors, and image reconstruction data were formed after retro-reconstructing of initial scanning data. MPVR, VR, and VB images were obtained respectively by postprocessing of image reconstruction data with MPVR, VR, and VB image processing software in AW workstation. The findings of MSCT initial axial images, MPVR, VR, and VB images were compared with surgical and pathological results. Results: MSCT initial axial images combined with MPVR, VR, and VB images displayed the locations (tracheae, n=19; right principal bronchi, n=6; left principal bronchi, n=6), morphologies (endoluminal nodular tumors with narrow bases, n=2; endoluminal nodular tumors with wide bases, n=13; intraluminal and extraluminal massive tumors, n=16), internal features (1 had homogeneous density, 1 had low density, they both without obvious enhancement; 23 squamous cell carcinomas and 3 adenocarcinomas had fairly homogeneous density and rather obvious enhancement; 1 had homogeneous density, 1 had inhomogeneous density, 1 had punctate calcification, all with obvious enhancement), extramural invasion situations (broke through only serous membrane, n=1; no clear border with right atelectatic lung tissue, n=1; ranges of extramural invasion 4-56 mm, n=14), morphologies of luminal stenoses (eccentric, n=1; irregular, n=26; circular, n=3; conical interruption, n=1), extents (mild, n=5; moderate, n=7; severe, n=19); measured longitudinal invasion ranges (only 3 mm, n=1; invaded the whole right principal bronchus wall and carina, n=1; 5-68 mm, n=29), and distances between principal bronchus tumors and carina (invaded carina, n=1

  8. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R.; Gaetani, P.; Rodriguez y Baena, R.; Cecchini, A.; Infuso, L.

    1998-01-01

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 ± 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 ± 0.12 cm vs 1.09 ± 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients. (orig.)

  9. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data

    Energy Technology Data Exchange (ETDEWEB)

    Klintstroem, Eva; Smedby, Oerjan [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); UHL County Council of Oestergoetland, Department of Radiology, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Moreno, Rodrigo [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Brismar, Torkel B. [KUS Huddinge, Department of Clinical Science, Intervention and Technology at Karolinska Institutet and Department of Radiology, Stockholm (Sweden)

    2014-02-15

    Bone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference. Fifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained. The clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini. The high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT. (orig.)

  10. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  11. A new approximate algorithm for image reconstruction in cone-beam spiral CT at small cone-angles

    International Nuclear Information System (INIS)

    Schaller, S.; Flohr, T.; Steffen, P.

    1996-01-01

    This paper presents a new approximate algorithm for image reconstruction with cone-beam spiral CT data at relatively small cone-angles. Based on the algorithm of Wang et al., our method combines a special complementary interpolation with filtered backprojection. The presented algorithm has three main advantages over Wang's algorithm: (1) It overcomes the pitch limitation of Wang's algorithm. (2) It significantly improves z-resolution when suitable sampling schemes are applied. (3) It avoids the waste of applied radiation dose inherent to Wang's algorithm. Usage of the total applied dose is an important requirement in medical imaging. Our method has been implemented on a standard workstation. Reconstructions of computer-simulated data of different phantoms, assuming sampling conditions and image quality requirements typical to medical CT, show encouraging results

  12. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    Directory of Open Access Journals (Sweden)

    Holger Wenz

    2016-01-01

    Conclusions: Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.

  13. Review: Pre- and postinterventional control of stent grafts by means of single and multislice spiral computerized tomography

    International Nuclear Information System (INIS)

    Gebauer, B.; Knollmann, F.; Steinkamp, H.; Felix, R.

    2003-01-01

    Purpose. Could contrast enhanced computed tomography replace conventional catheter angiography in the preoperative evaluation of aortic aneurysms before stentgraft implantation? Does multi slice computed tomography have advantages comparing to single slice computed tomography? Methods. We compared 15 single slice with 13 multi slice computed tomography studies and reconstructions according to their ability to replace conventional catheter angiography in the preoperative evaluation. In the postoperative follow-up 60 single slice computed tomography studies were compared to 60 multi slice studies. Results. By using appropriate reconstructions the spiral computed tomography studies could deliver all information necessary for implantation. In our study no advantage of multi slice computed tomography could be detected. In the postoperative evaluation of stengrafts our computed tomography scan protocol could detect all relevant complications in single and multi slice computed tomography. No significant advantage of multi slice computed tomography could be detected. Conclusion. Contrast enhanced computed tomography is equal to conventional catheter angiography in the pre- and postoperative evaluation of stentgrafts. No significant advantage of multi slice versus single slice could be detected. (orig.) [de

  14. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  15. Multi-slice helical CT: biggest pitch does not mean dosimetric bargain

    International Nuclear Information System (INIS)

    Cordoliani, Y.S.

    2000-01-01

    This article explains the point of the definition of the pitch, definition different from the point of view of the constructor and the definition used in the normalisation documents. It is important to dissociate the detection step ( displacement of the way divided by the thickness of the reconstructed hits) and the acquisition step (displacement of the way divided by the product of the number of hits simultaneously achieved by the nominal thickness of hit). This last one is the only step that answers to the step definition, still current in the normalisation documents and it should be the only used by the constructors. As irradiation is inversely proportional to the pitch, the definition of this one becomes a part of radiation protection and explains why different radiation doses can be gotten. (N.C.)

  16. Detection and severity of coronary disease: comparison between Framingham and calcium scores using multi-slice tomography

    International Nuclear Information System (INIS)

    Rodriguez Gomez, Maria Liliana; Montenegro, Edison; Ruiz, Angela Maria; Ardila, Jaime

    2011-01-01

    Introduction: multiple studies have shown that the coronary calcium index is an independent, more accurate predictor of future coronary events in relation to traditional risk factors. However, these studies have not been conducted in populations of developing countries like Colombia. Objective: to compare the strength of association between the Framingham index and the coronary calcium score in detecting the presence and severity of coronary disease as defined by 64-channel multi-slice angio-CT in order to provide additional information for decision-making in our asymptomatic coronary population. Methodology: we reviewed the written reports of coronary angiography scans performed in past 3 years. Based on this information, bivariate (calculation of Spearman rho correlation coefficients) and multivariate (logistic regression) analyses were performed. Results: the coronary calcium score showed a higher correlation with the presence and severity of coronary disease, Spearman Rho coefficient, compared with the Framingham index, Spearman's Rho coefficient of 0.30 (p<0.001). The moderate Framingham index (10-19%) shows no strength of association with significant and non-significant coronary artery disease, OR = 2, 51 CI 95% (0.7-8.9) and OR = 2.3 CI 95% (0.86-6.15), respectively. Patients with calcium values = 100 showed significant strength of association, OR = 182, 95% (17.4 -190.2), with significant coronary disease compared with high Framingham index values (=20%), OR = 18.6, CI 95% (1.75-198). Conclusions: the coronary calcium score has a higher correlation with the presence and severity of coronary disease when compared with the Framingham index. There is a low correlation between the index and Framingham coronary calcium.

  17. Towards truly integrated hardware fusion with PET/CT

    International Nuclear Information System (INIS)

    Beyer, T.

    2005-01-01

    Combined PET/CT imaging is a non-invasive means of acquiring and reviewing both, the anatomy and the molecular pathways of a patient during a quasi-simultaneous examination. Since the introduction of the prototype PET/CT in 1998 this imaging technology has evolved rapidly. State-of-the-art PET/CT tomographs combine the latest technology in spiral, multi-slice CT and PET using novel scintillator materials and image reconstruction techniques. Together with novel patient positioning systems PET/CT tomographs allow to acquire complementary PET and CT data in a single exam with the best intrinsic co-registration. In addition to the hardware integration efforts have been made to integrate the acquisition and viewing software in PET/CT, thus making the diagnostic review and reporting more efficient. Based on the first clinical experiences and the technical evolution of combined imaging technology PET/CT has become a standard in diagnostic oncology. With high-performance imaging technology at hand today, standardized, high-quality PET/CT imaging protocols are needed to provide best oncology patient care. These protocols mandate the joint efforts of a multi-disciplinary team of physicians, physicists and radiochemists. (orig.)

  18. Application of triple rule-out with 64-slice spiral CT in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Li Pengyu; Li Kuncheng; Du Xiangyin; Cao Lizhen; Liu Jiabin; Yang Yanhuui; Liang Zhigang; Zhu Xiaolian; Liu Jian

    2007-01-01

    Objective: To investigate the performance of triple rule-out with 64-slice spiral CT in the combined examination of pulmonary artery, thoracic aorta and coronary artery for patients with acute chest pain. Methods: Seventy patients who presented with acute chest pain were included in the study. All of the patients underwent retrospective ECG-gated 64-slice computed tomography triple rule-out examination to evaluate the pulmonary arteries, thoracic aorta and coronary arteries. Multi-planar reconstruction (MPR), maximum intensity projection (MIP), curved-planar reconstruction (CPR) and volume rendering (VR) were used to display pulmonary arteries, thoracic aorta and coronary arteries. We evaluated the image quality of coronary artery and the enhancement of the pulmonary artery and thoracic aorta to estimate if the examination can fulfill the clinical demand for the differential diagnosis of acute chest pain. Results: The mean scan time was (8.5±1.0) s, and the dose of contrast medium injected was 100 ml. There were 95.7% (67/70) of patients whose CT values detected in the pulmonary artery and thoracic aorta after enhancement Were ≥200 HU. The image quality of 85.8% (720/839) coronary segments was classified as excellent, 8.6% (72/839) as good, and 5.6% (47/839) as poor. There were 20 eases with coronary stenoses ≥50%, 2 cases with pulmonary embolism, and 2 cases with aortic dissection. Conclusion: The triple rule-out examination with 64-slice spiral CT could depict pulmonary artery, thoracic aorta, and coronary artery in 8 s with good image quality. It has great potential in the etiological diagnosis for the patients with acute chest pain. (authors)

  19. A simultaneous multi-slice selective J-resolved experiment for fully resolved scalar coupling information

    Science.gov (United States)

    Zeng, Qing; Lin, Liangjie; Chen, Jinyong; Lin, Yanqin; Barker, Peter B.; Chen, Zhong

    2017-09-01

    Proton-proton scalar coupling plays an important role in molecular structure elucidation. Many methods have been proposed for revealing scalar coupling networks involving chosen protons. However, determining all JHH values within a fully coupled network remains as a tedious process. Here, we propose a method termed as simultaneous multi-slice selective J-resolved spectroscopy (SMS-SEJRES) for simultaneously measuring JHH values out of all coupling networks in a sample within one experiment. In this work, gradient-encoded selective refocusing, PSYCHE decoupling and echo planar spectroscopic imaging (EPSI) detection module are adopted, resulting in different selective J-edited spectra extracted from different spatial positions. The proposed pulse sequence can facilitate the analysis of molecular structures. Therefore, it will interest scientists who would like to efficiently address the structural analysis of molecules.

  20. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  1. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT

    NARCIS (Netherlands)

    M. Oudkerk (Matthijs); C.G. Torres; B. Song; M. Konig; J. Grimm; J. Fernandez-Cuadrado; B. op de Beeck; M. Marquardt; P. van Dijk (Pieter); J.C. de Groot (Jan Cees)

    2002-01-01

    textabstractPURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were

  2. Virtual reality publication of spiral ct-derived three-dimensional models: or, creation of spiral, CT-derived, three-dimensional VRML objects.

    Science.gov (United States)

    Tyszka, J M

    1997-01-01

    Three-dimensional models can be generated from slice images, such as those obtained from computed tomography (CT) and magnetic resonance imaging (MRI) using a variety of techniques. A popular method for rendering 3D anatomical models is the creation of polygonal mesh surfaces representing the boundary between tissues. Mesh surfaces can be rendered extremely quickly using conventional personal computers, without recourse to more expensive graphic workstations. The dissemination of three-dimensional (3D) models across the Internet has been made significantly easier by the definition of the Virtual Reality Markup Language (VRML) format. The VRML definition allows the parameters and relationships of 3D objects to be described in a text format. The text file can be transfered from a host computer to a remote client computer through the World Wide Web and viewed using readily available software (See Appendix). VRML is based on the definition of primitive 3D objects such as polygons and spheres. Consequently, the transition from a mesh surface derived from a clinical image data set to a VRML object is relatively simple, allowing for convenient and cost-effective dissemination of 3D clinical models across the internet.

  3. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A. [Ospedale S. Maria delle Grazie, Pozzuoli, NA (Italy). Servizio di Radiologia; Nunziata, A. [Ospedale S. Maria delle Grazie, Naples (Italy). Area di Diagnostica per Immagini

    2000-06-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyper attenuation in the arterial phase and hypo-iso attenuation in the portal and/or delayed phase, or with hypo-iso attenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hyper vascular and 1 hypo vascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemo embolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this

  4. Evaluation of image quality and dose in thoracic spiral CT examination in patients with pulmonary carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Moran-Blanco, L. M.; Rodriguez-Gonzalez, R.; Calzado-Cantera, A.; Arenas de Pablo, A.; Baeza-Trujillo, M.; Cuevas-Ibanez, A.; Garcia-Castano, B.; Gomez-Leon, N.; Turrero-Nogues, A.; Moran-Penco, P.

    2002-01-01

    We have applied criteria for CT quality defined in the European Guidelines to a samples of thoracic CT examinations for the indication of pulmonary carcinoma of 5 institutions of the Community of Madrid that have spiral CT equipment. The selected examinations have been evaluated independently by five radiologists to determine the degree of adherence to the quality criteria for image defined in the Guidelines s for examinations of general thorax. Dosimetric measurements carried out in parallel have served to estimate the values of CT (CTDI w ) dose indices, dose-length product (DLP) and effective dose for every patient. The result show a high global adherence to the quality criteria (96%), with averages per institution being between 94% (in two institutions) and 98% (in three institutions). There are 10 of 16 criteria that are adhered to in all examinations of the sample: those which are not adhered to systematically are: two of visualization (1.1 and 1.4), with 92-96% fulfillment, and four of critical reproduction (2.6; 2.8; 2.9 and 2.10), with percentages of adherence between 91% and 96%. The average CTDI w values per institution are in the interval 12.9-19.1 mGy; those of DLP between 263 and 577 mGy cm and those of effective dose between 4.2 and 9.2 mSv. The DLP-image quality correlation in institutions with the best image quality was null in two of them and direct and moderate in the third. In both institutions with the poorest image: (Author) 20 refs

  5. The application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement

    International Nuclear Information System (INIS)

    Wei Ning; Xu Hao; Zu Maoheng; Gu Yuming; Li Gang; Zhang Qingqiao; Xu Wei; Cui Yanfeng; Liu Hongtao; Wang Wenliang

    2012-01-01

    Objective: To evaluate the application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement. Methods: Thirty-one patients treated with tracheal stents were retrospectively analyzed, of which there were 27 malignant tracheal stenosis, 2 benign tracheal stenosis, 1 bronchial remnant fistula and 1 gastroesophageal anastomosis tracheal fistula. The spiral-CT and 3D-imagings were analyzed and the location, shape and complication of the stents were assessed. Results: Thirty-one patients were treated with 8 Z-type stainless steel stents and 28 Ni-Ti memory alloy stents. The stents of 22 cases remained patent in the original position and restenosis was occurred in 5 cases, migration in 3 cases and fracture in 1 case. All the CT features were performed and reconstructed on the workstation, using multiplanar reconstruction, volume rendering, and CT virtual endoscopy. The location of tracheal stenosis and fistula were showed in different angle, and the location, shape of the stents, and the complications (such as restenosis, fracture) as well. Conclusion: Spiral-CT and 3D-imaging is a rapid, simple and effective method in assessing tracheal stent implantation and complication, therefore, it is of great value in clinical practice. (authors)

  6. Congenital intrahepatic arterioportal and portosystemic venous fistulae with jejunal arteriovenous malformation depicted on multislice spiral CT

    International Nuclear Information System (INIS)

    Chae, Eun Jin; Goo, Hyun Woo; Yoon, Chong Hyun; Kim, Seong-Chul

    2004-01-01

    We report a symptomatic infant with very rare congenital arterioportal and portosystemic venous fistulae in the liver. Multislice CT after partial transcatheter embolisation revealed not only the complicated vascular architecture of the lesion, but also an incidental jejunal arteriovenous malformation which explained the patient's melena. The patient underwent ligation of the hepatic artery and resection of the jejunal arteriovenous malformation. Postoperative multislice CT clearly demonstrated the success of the treatment. (orig.)

  7. Gastrointestinal stromal tumor: role of spiral CT in diagnosis and evaluation of treatment with STI571

    International Nuclear Information System (INIS)

    Hu Jiawang; Zhou Linjiang; Wei Jiangong

    2011-01-01

    Objective: To investigate the CT appearance of gastrointestinal stromal tumors (GISTs) after oral imatinib mesylate (STI571) treatment. Methods: CT scans of 58 cases of GISTs proven by histology and immunohistochemistry were retrospectively analyzed. Dynamic contrast-enhanced CT of 8 patients after STI571 treatment was also evaluated. Results: The tumors originated from the stomach (n=28), small intestine (n=12), duodenum (n=6), colon (n=5), rectum (n=4), mesentery (n=2), and esophagus (n=2). Small GISTs appeared as round or oval, endo- or exophytic masses with well-defined margins and homogeneous contrast enhancement. Large lesions were often irregular infiltrative exophytic masses with heterogeneous enhancement. Ulceration, fistulization and neovascularity can be seen within the larger tumors. CT scans of 5 patients with good treatment response showed rapid transition form a heterogeneously hyper-attenuating pattern to homogeneously hypo-attenuating pattern with resolution of the enhancing tumor nodules and decreased tumor neovascularity. In 3 poor responders, CT showed enlarging or new enhancing nodules within the treated hypo-attenuating tumor, new lesions or metastasis outside the primary tumor. Conclusion: CT can demonstrate changes resulting from treatment of GISTs. It is valuable for guiding and assessing treatment response to STI571. (authors)

  8. Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning

    International Nuclear Information System (INIS)

    Ford, E.C.; Mageras, G.S.; Yorke, E.; Ling, C.C.

    2003-01-01

    We describe a method for generating CT images at multiple respiratory phases with a single spiral CT scan, referred to as respiratory-correlated spiral CT (RCCT). RCCT relies on a respiration wave form supplied by an external patient monitor. During acquisition this wave form is recorded along with the initiation time of the CT scan, so as to 'time stamp' each reconstructed slice with the phase of the respiratory cycle. By selecting the appropriate slices, a full CT image set is generated at several phases, typically 7-11 per cycle. The CT parameters are chosen to optimize the temporal resolution while minimizing the spatial gap between slices at successive respiratory cycles. Using a pitch of 0.5, a gantry rotation period of 1.5 s, and a 180 degree sign reconstruction algorithm results in ∼5 mm slice spacing at a given phase for typical respiration periods, and a respiratory motion within each slice that is acceptably small, particularly near end expiration or end inspiration where gated radiotherapy is to occur. We have performed validation measurements on a phantom with a moving sphere designed to simulate respiration-induced tumor motion. RCCT scans of the phantom at respiratory periods of 4, 5, and 6 s show good agreement of the sphere's motion with that observed under fluoroscopic imaging. The positional deviations in the sphere's centroid between RCCT and fluoroscopy are 1.1±0.9 mm in the transaxial direction (average over all scans at all phases ±1 s.d.) and 1.2±1.0 mm in the longitudinal direction. Reconstructed volumes match those expected on the basis of stationary-phantom scans to within 5% in all cases. The surface distortions of the reconstructed sphere, as quantified by deviations from a mathematical reference sphere, are similar to those from a stationary phantom scan and are correlated with the speed of the phantom. A RCCT scan of the phantom undergoing irregular motion, demonstrates that successful reconstruction can be achieved even with

  9. The technique advantages of 16-detector multic-slice spiral CT in evaluating combined pulmonary and deep vein thromboembolism

    International Nuclear Information System (INIS)

    Xia Shuang; Qi Ji; Lei Xinwei; Wen Lianqing; Li Yiming; Liu Jisheng

    2004-01-01

    Objective: To study the scanning technique of 16-detector multic-slice spiral CT(MSCT) for combined pulmonary artery and deep vein of lower limb in pulmonary thromboembolism (PE) patients. Methods: Forty suspected pulmonary thromboembolism patients were performed both pulmonary artery angiography (CTA) and indirect deep vein venography (CTV) on 16-detector MSCT. The parameters of the latter as following: total contrast volume 120-150 ml, injection rate 4.0-4.5 ml/s (from antecubital vein), delay time 4.0 for CTA 20-23 s, CTV 120-180 s, collimation for CTA 1.25 mm and 0.625 mm, CTV 2.5 mm, scan range of CTV: from popliteal vein to the level of bilateral renal vein into the inferior vena cava. Postprocessing include MPR, MIP, and VR. The test was used to analyzed the images. Results: Twenty five patients had both pulmonary thromboembolism (PE) and deep vein thromboembolism (DVT), 8 patients had only DVT, 2 had only PE, and 5 had neither. There was no difference between different collimation in depicting thrombus. The CT value number of enhanced pulmonary artery and lower deep vein was obviously higher than the thrombus. The value of MPR, MIP, VR for PE was 100%, 100%, and 65%, The value of MPR, MIP, VR for DVT is 100%, 60%, and 50%. Conclusion: The technique of combined pulmonary CTA and deep vein CTV of 16-detector MSCT will provide a new modality for pulmonary thromboembolism patients. (author)

  10. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor`s note

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, F.V. [Abdominal Imaging Section, Department of Radiology, University of California, San Francisco, CA (United States); Cohen, M.D. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Waters, D.J. [Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN (United States); Davis, M.M. [Department of Pathology, Riley Hospital for Children, Indianapolis, IN (United States); Karmazyn, B. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Gonin, R. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States); Hanna, M.P. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States)

    1997-07-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs.

  11. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor's note

    International Nuclear Information System (INIS)

    Coakley, F.V.; Cohen, M.D.; Waters, D.J.; Davis, M.M.; Karmazyn, B.; Gonin, R.; Hanna, M.P.

    1997-01-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs

  12. The comparative study of various oral contrast media in 3D display of gastric lesions in spiral CT

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Peng Weijun

    2001-01-01

    Objective: To optimize the oral contrast media in three-dimensional display of gastric lesions. Methods: 41 cases were randomly divided into 3 groups according to different oral contrast media administered: No. 1 air contrast group (n = 17), No. 2 fat emulsion group (n = 7) and No. 3 positive contrast group (n = 25). The 3D CT images were reconstructed using MPR, SSD, RaySum display and virtual endoscopic techniques, and compared with gastric endoscopy and/or conventional barium study. Results: The detectability of gastric lesions using fat emulsion and air contrast was 42.8%(3/7) and 80.0%(20/25), respectively, both were significantly lower than that using positive contrast (100%, 30/30) (x 2 = 19.22, P 2 = 6.60, P 2 = 17.04, P < 0.01). Conclusion: It is very important to choose the appropriate oral contrast media for 3D display of gastric lesions in spiral CT, the positive contrast agent is the optimal choice

  13. Clinical application of multislice spiral CT angiography in evaluation of anomalous vertebral artery

    International Nuclear Information System (INIS)

    Hua Rui; Liu Jun; Zhang Yu

    2008-01-01

    Objective: To evaluate the diagnostic value of 16-slice spiral computed tomography angiography (MSCTA) in evaluation of anomalous vertebral artery. Methods: MSCTA data from 32 patients with anomalous vertebral artery were retrospectively analyzed. Results: 22 cases had vertebral artery course variation (bended into the C 5 , C 4 or C 3 foramen transversarium), 7 cases had variation in the prevertebral segments of vertebral arteries, 15 patients had unilateral vertebral congenital stenosis, 1 case had double vertebral artery branch, 1 case had vertebral arterial fenestration, and 2 cases had vertebral artery in one side that did not converged upon basilar artery and unilateral vertebral artery formed basilar artery. Conclusion: MSCTA is a useful noninvasive imaging tool for the diagnosis of vertebral artery variations. (authors)

  14. Blunt traumatic rupture of a mainstem bronchus: spiral CT demonstration of the ''fallen lung'' sign

    International Nuclear Information System (INIS)

    Wintermark, M.; Schnyder, P.; Wicky, S.

    2001-01-01

    Tracheo-bronchial injuries occur in less than 1 % of blunt chest trauma patients. Indirect signs, such as pneumomediastinum, pneumothorax, and/or subcutaneous emphysema, are revealed on admission plain films and chest CT survey. In most instances, however, tracheo-bronchoscopy is mandatory in assessing the definite diagnosis of tracheo-bronchial lesion. Occasionally, an abnormal course of a mainstem bronchus or a ''fallen lung'' sign, featuring a collapsed lung in a dependent position, hanging on the hilum only by its vascular attachments, may allow for CT diagnosis of a blunt traumatic bronchial injury. (orig.)

  15. Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode

    International Nuclear Information System (INIS)

    Wolf, Florian; Loewe, Christian; Plank, Christina; Schernthaner, Ruediger; Bercaczy, Dominik; Lammer, Johannes; Leschka, Sebastian; Goetti, Robert; Marincek, Borut; Alkadhi, Hatem; Homolka, Peter; Friedrich, Guy; Feuchtner, Gudrun

    2010-01-01

    To evaluate coronary stents in vitro using 128-slice-dual-source computed tomography (CT). Twelve different coronary stents placed in a non-moving cardiac/chest phantom were examined by 128-slice dual-source CT using three CT protocols [high-pitch spiral (HPS), sequential (SEQ) and conventional spiral (SPIR)]. Artificial in-stent lumen narrowing (ALN), visible inner stent area (VIA), artificial in-stent lumen attenuation (ALA) in percent, image noise inside/outside the stent and CTDIvol were measured. Mean ALN was 46% for HPS, 44% for SEQ and 47% for SPIR without significant difference. Mean VIA was similar with 31% for HPS, 30% for SEQ and 33% for SPIR. Mean ALA was, at 5% for HPS, significantly lower compared with -11% for SPIR (p = 0.024), but not different from SEQ with -1%. Mean image noise was significantly higher for HPS compared with SEQ and SPIR inside and outside the stent (p < 0.001). CTDIvol was lower for HPS (5.17 mGy), compared with SEQ (9.02 mGy) and SPIR (55.97 mGy), respectively. The HPS mode of 128-slice dual-source CT yields fewer artefacts inside the stent lumen compared with SPIR and SEQ, but image noise is higher. ALN is still too high for routine stent evaluation in clinical practice. Radiation dose of the HPS mode is markedly (less than about tenfold) reduced. (orig.)

  16. Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results

    International Nuclear Information System (INIS)

    Greess, H.; Bautz, W.; Baum, U.; Wolf, H.; Suess, C.; Kalender, W.A.

    2004-01-01

    Purpose: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. Materials and Methods: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n=26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. Results: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31% to 66% in children (mean 44%) and between 35% and 64% in adults (mean 53%), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. Conclusion: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality. (orig.) [de

  17. Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

    International Nuclear Information System (INIS)

    Frennby, B.; Almen, T.

    2001-01-01

    The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r=0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol). (orig.)

  18. Multi-slicing strategy for the three-dimensional discontinuity layout optimization (3D DLO).

    Science.gov (United States)

    Zhang, Yiming

    2017-03-01

    Discontinuity layout optimization (DLO) is a recently presented topology optimization method for determining the critical layout of discontinuities and the associated upper bound limit load for plane two-dimensional and three-dimensional (3D) problems. The modelling process (pre-processing) for DLO includes defining the discontinuities inside a specified domain and building the target function and the global constraint matrix for the optimization solver, which has great influence on the the efficiency of the computation processes and the reliability of the final results. This paper focuses on efficient and reliable pre-processing of the discontinuities within the 3D DLO and presents a multi-slicing strategy, which naturally avoids the overlapping and crossing of different discontinuities. Furthermore, the formulation of the 3D discontinuity considering a shape of an arbitrary convex polygon is introduced, permitting the efficient assembly of the global constraint matrix. The proposed method eliminates unnecessary discontinuities in 3D DLO, making it possible to apply 3D DLO for solving large-scale engineering problems such as those involving landslides. Numerical examples including a footing test, a 3D landslide and a punch indentation are considered, illustrating the effectiveness of the presented method. © 2016 The Authors. International Journal for Numerical and Analytical Methods in Geomechanics published by John Wiley & Sons Ltd.

  19. Accelerating Magnetic Resonance Fingerprinting (MRF) using t-Blipped Simultaneous Multi-Slice (SMS) acquisition

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F.; Du, Yiping; Wald, Lawrence L.; Griswold, Mark A.; Setsompop, Kawin

    2015-01-01

    Purpose We incorporate Simultaneous Multi-Slice (SMS) acquisition into MR Fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Further, by varying the Gz blip area and/or polarity as a function of TR, the slices’ differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from Multi-band factor (MB)=2 t-Blipped SMS-MRF shows good accuracy and precision when compared to results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. Conclusions The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. PMID:26059430

  20. A multi-slice sliding cell technique for diffusion measurements in liquid metals

    Science.gov (United States)

    Zhong, Langxiang; Hu, Jinliang; Geng, Yongliang; Zhu, Chunao; Zhang, Bo

    2017-09-01

    The long capillary and shear-cell techniques are traditionally used for diffusion measurements in liquid metals. Inspired by the idea of the shear-cell method, we have built a multi-slice sliding cell device for inter-diffusion measurements in liquid metals. The device is designed based on a linear sliding movement rather than a rotational shearing as used in the traditional shear-cell method. Compared with the normal shear-cell method, the present device is a more compact setup thus easier to handle. Also, it is expected to be easier to monitor with X-rays or neutrons if used in in situ experiments. A series of benchmark time-dependent diffusion experiments in Al-Cu melts carried out with the present technique reveal that accurate diffusion constants can be achieved only after a sufficient time. For short annealing times, the initial shearing process causing convective flow dominates the measurement and leads to an increase of the measured diffusion coefficient by a factor three. The diffusion data obtained for Al-Cu liquids are consistent with the most accurate data measured by the in situ X-ray radiography method under well controlled conditions of no temperature gradient or other perturbation. High accuracy and easy handling as well as superior adaptability make the present technique suitable for diffusion studies in liquid metals.

  1. Multi-slice computed tomography urography after diuretic injection in children with urinary tract dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Kosucu, P.; Ahmetoglu, A.; Imamoglu, M.; Cay, A.; Ozdemir, O.; Dinc, H.; Kosucu, M.; Sari, A.; Saruhan, H.; Gumele, H.R. [Farabi Hospital, Trabzon (Turkey). Dept. of Radiology

    2004-02-01

    To evaluate the potential use of multi-slice computed tomography urography (MSCTU) after diuretic injection in children with urinary tract dilatation. MSCTU was performed in 19 patients (11 boys, 8 girls, mean age 5.4 years) with suspicion of urinary tract obstruction and dilatation. Furosemide, 1 mg/kg, was injected 3 min before contrast material administration and followed by a bolus of 30 ml of physiologic saline solution immediately after application of contrast material. Excretory-phase images were obtained through the abdomen and pelvis beginning 10 min after initiation of the injection of contrast material. Maximum intensity projection (MIP) and volume rendering (VR) images were post-processed to obtain urographic views. MSCTU revealed pathology in 16 of 19 patients, while 3 patients had normal findings. Ureteropelvic obstruction was found in 4 patients, obstructive megaureter in 8. Both ureteropelvic obstruction and obstructive megaureter were disclosed in 1 patient, partial ureteral duplication in 1 patient, and both complete ureteral duplication and ureterocele in 2 patients. In all patients, MIP and VR images could satisfactorily show the pathologies of the urinary tract. The estimated effective average doses of MSCTU were higher than IVU. Preliminary results of furosemide-enhanced MSCTU demonstrated consistently dilated urinary tracts, obstruction levels, and underlying pathologies better than US and IVU.

  2. Evaluation of the accuracy of linear measurements on multi-slice and cone beam computed tomography scans to detect the mandibular canal during bilateral sagittal split osteotomy of the mandible.

    Science.gov (United States)

    Freire-Maia, B; Machado, V deC; Valerio, C S; Custódio, A L N; Manzi, F R; Junqueira, J L C

    2017-03-01

    The aim of this study was to compare the accuracy of linear measurements of the distance between the mandibular cortical bone and the mandibular canal using 64-detector multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT). It was sought to evaluate the reliability of these examinations in detecting the mandibular canal for use in bilateral sagittal split osteotomy (BSSO) planning. Eight dry human mandibles were studied. Three sites, corresponding to the lingula, the angle, and the body of the mandible, were selected. After the CT scans had been obtained, the mandibles were sectioned and the bone segments measured to obtain the actual measurements. On analysis, no statistically significant difference was found between the measurements obtained through MSCT and CBCT, or when comparing the measurements from these scans with the actual measurements. It is concluded that the images obtained by CT scan, both 64-detector multi-slice and cone beam, can be used to obtain accurate linear measurements to locate the mandibular canal for preoperative planning of BSSO. The ability to correctly locate the mandibular canal during BSSO will reduce the occurrence of neurosensory disturbances in the postoperative period. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Pulmonary embolism: Prospective comparison of spiral CT with ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Mayo Jhon R; Remi Jardin, Martine; Muller Mestor I

    1999-01-01

    The pulmonary thromboembolism (PTE) it is an entity common with great morbidity and mortality that it requires a diagnosis soon and specify. Commonly the ventilation gammagraphy - perfusion has been the used exam of first more frequent line when one suspects the PTE but unfortunately a great quantity of reports is called of intermediate probability, for what requires complementary studies, to confirm or to discard the diagnosis. A prospective study was made with 142 patients that had suspicion of TEP in the hospital of Vancouver (Canada) and in the hospital of Calmette (France), being carried out in all gammagraphy of ventilation-perfusion and helical CT, being only taken to lung angiography to those that not had high clinical suspicion of TEP with gammagraphy or helical CT very suggestive or tuneless, undergoing the results valuation for different observers

  4. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  5. Spiral CT angiography (SCTA) study of celiac artery and superior mesenteric artery

    International Nuclear Information System (INIS)

    Yuan Zhenguo; Zhou Cunsheng; Xu Zuodong; Shi Hao; Wang Tao

    1999-01-01

    Objective: To study the visualization capability and scanning technique of SCTA in celiac artery, superior mesenteric artery (SMA) and other branches. Methods: Thirty patients, with normal abdominal SCTA results, were given small injection test dose after plain scan. The abdominal aorta parallel to the body of pancreas was chosen as target vessel, the peak-time plus 2 seconds as the best delay scan time. Iodine contrast medium 90∼110 ml was injected into antecubital vein at the speed of 3.5 ml/s, then scan from cranial to caudal was performed. Pitch 1.0 and slice thickness 3.2 mm were selected as the scan parameters. Maximum intensity projection (MaxIP) was employed in all patients and shaded surface display (SSD) in 23 cases. Results: The display rate using MaxIP and SSD of celiac artery, splenic artery, common hepatic artery, proper hepatic artery and SMA were all 100%, the gastroduodenal artery 100% and 91%, the left gastric artery 83% and 87%, respectively. Conclusions: SCTA as a minimally invasive examination is a valuable method to detect and diagnose disease or variations of celiac artery, its branches and SMA. Spiral scanning technique and image processing have a decisive effect on the image quality

  6. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  8. Evaluation of right coronary anomalous origin with mulpi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Han Ping; Kong Xiangquan; Feng Hansheng; Brambs, H.-J.; Hoffmann, M.H.K.

    2006-01-01

    Objective: To evaluate the role of 16-slice spiral computed tomography angiography (MSCTA) to identify the anomalous origin and anatomic course of the right coronary artery (RCA) with conventional X-ray coronary angiography (CAG) serving as standard of reference. Methods: MSCTA data in 8 patients with anomalous RCA were retrospectively analyzed for the study, 7 of them had also undergone CAG examinations. MSCTA and CAG images were analyzed in blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Virtual endoscopy (VE) was used to evaluate the orifice of the anomalous arteries and its relationship with the adjacent ostia of normal arteries. Multi-planar reconstruction (MPR), curved MPR, thin-slab maximum intensity projection (MIP), volume rendering (VR) or slab VR (cut-plane VR) were used to assess the aberrant path of the RCA and its relationship with the adjacent large vessels. At least two views of the RCA were analyzed on CAG. Results: The anomalous RCA for all 8 patients were correctly displayed on MSCTA. RCA originated from the left sinus of Valsalva in 6 patients, one RCA from the end of left main coronary artery, another RCA arose from the posterior sinus of Valsalva. The anomalous ostia showed no stenosis. All of them passed between the aortic root and the pulmonary artery. For 7 patients with CAG alone correct identification of the abnormality was achieved in only 71%. Conclusion: MSCTA was superior to show the anomalous orifice and path of the RCA, it should be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (authors)

  9. 3D spiral CT imaging of bone anomalies in a case of diastematomyelia

    International Nuclear Information System (INIS)

    Skalej, Martin; Duffner, Frank; Stefanou, Alexander; Petersen, Dirk

    1999-01-01

    The case of a 48-year-old woman, suffering from a diastematomyelia, is presented. This case and the diagnostic findings are used to demonstrate the demands on imaging methods with respect to a new classification of split cord malformations (SCMs) recently published. Although MRI is the method of choice for imaging of the spinal cord generally, only X-ray methods and especially conventional computer tomography provide the information necessary for correct classification of SCMs. Additional 3D-reconstructions from suitable CT-data are helpful in visualizing complex anomalies of bony structures found in most cases of SCM

  10. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  11. Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E.; Dorzee, Benjamin; Berg, Bruno C. vande; Malghem, Jacques [Cliniques Universitaires St Luc, Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Dubuc, Jean E. [Cliniques Universitaires St Luc, Universite Catholique de Louvain, Department of Orthopaedic Surgery, Brussels (Belgium); Jamart, Jacques [Mont Godinne University Hospital, Center of Biostatistics, Yvoir (Belgium)

    2007-07-15

    This study assessed the diagnostic effectiveness of multidetector spiral CT arthrography (MDCTa) in detecting hyaline cartilage abnormalities of the shoulder joint, with correlation to arthroscopy. Shoulder MDCTa images prospectively obtained in 22 consecutive patients (mean age, 50 years; age range, 23-74 years; 12 female, 10 male) were evaluated for glenohumeral cartilage lesions. Two musculoskeletal radiologists independently analysed the cartilage surfaces of the humeral head and of the glenoid fossa in nine anatomical surface areas. Observations of MDCTa were compared to arthroscopic findings. The sensitivity and specificity of MDCTa for grade 2 (substance loss <50%) or higher and grade 3 (substance loss {>=}50%) or higher cartilage lesions, the Spearman correlation coefficient between arthrographic and arthroscopic grading, and K statistics for assessing Intra and Interobserver reproducibility were determined. At MDCTa, sensitivities and specificities ranged between 80% and 94% for the detection of grade 2 or higher cartilage lesions, and between 88% and 98% for the detection of grade 3 or higher cartilage lesions. Spearman correlation coefficients between MDCTa and arthroscopic grading of articular surfaces ranged between 0.532 and 0.651. Interobserver agreement was moderate for grading all articular surfaces ({kappa} = 0.457), but substantial to almost perfect for detecting lesions with substance loss ({kappa}, 0.618-0.876). In conclusion, MDCTa is accurate for the study of cartilage surface in the entire shoulder joint. This technique may beneficially impact patient's management by means of selecting the proper treatment approach. (orig.)

  12. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    International Nuclear Information System (INIS)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing; Zheng, Xiangpeng; Chen, Yan; Lv, Fangzhen

    2013-01-01

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  13. Accuracy of spiral CT and 3D reconstruction in the detection of acute pulmonary embolism - development of an animal model using porcine lungs and technical specimens. Development of an animal model using porcine lungs and technical specimens; Diagnostik der akuten Lungenembolie mittels Spiral-CT und 3D-Rekonstruktion. Entwicklung eines Tiermodells und technischer Probekoerper im Ex-vivo-Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ries, B.G. [Klinik und Poliklinik fuer Radiologie, Univ. Mainz (Germany); Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Kauczor, H.U.; Thelen, M. [Klinik und Poliklinik fuer Radiologie, Univ. Mainz (Germany); Konerding, M.A. [Anatomisches Inst., Mainz Univ (Germany)

    2001-02-01

    Purpose: To develop a model for simulation the CT morphologic situation of acute pulmonary embolism, to evaluate the accuracy of spiral CT and 3D reconstruction in the detection of artificial emboli and to investigate the influence of the orientation of emboli depending on z-axis orientation. Materials and Methods: Standardized artificial emboli made of wax and of defined size and shape were positioned into the pulmonary arteries of porcine lungs. Castings of the embolized pulmonary arterial trees were made by injection of a special opaque resin. After performance of spiral CT the data sets of the emboli and the pulmonary arteries were post-processed. The 3D segmentations were compared with the anatomic preparation to evaluate the accuracy of spiral CT/3D reconstruction-technique. Technical specimens simulating CT-morphology of acute embolized vessels underwent spiral CT in six different positions with respect to the z-axis. The CT data were reconstructed using a standardized and a contrastadapted method with interactive correction. The 3D emboli were analysed under qualitative aspects, and measurements of their extent were done. Results: In nearly 91%, there was complete agreement between CT and the corresponding findings at the anatomical preparation. Measurements of the 3D reconstructed technical specimens showed discrepancies of shape and size in dependence of the size of the original preparation, orientation and reconstruction technique. Overestimation up to 4 mm and underestimation to 2,2 mm were observed. Measurements of preparations with heights from 14 to 26 mm showed variances of {+-}1,5 mm ({proportional_to}6-11%). Conclusion: The presented models are suitable to simulate CT morphology of acute pulmonary embolism under ex-vivo conditions. Accuracy in the detection of artificial emboli using spiral CT/3D reconstruction is affected by localization, size and orientation of the emboli and the reconstruction technique. (orig.) [German] Ziel: Die Entwicklung

  14. Clinical application of three-dimensional spiral CT cerebral angiography with volume rendering

    International Nuclear Information System (INIS)

    Duan Shaoyin; Huang Xi'en; Kang Jianghe; Zhang Dantong; Lin Qingchi; Cai Guoxiang; Xu Meixin; Pang Ruilin

    2002-01-01

    Objective: To study the methodology and assess the clinical value of three-dimensional CT angiography (3D-CTA) with volume rendering (VR) in cerebral vessels. Methods: Sixty-two patients were examined by means of 3D-CTA with volume rendering. VR was used in the reconstruction of 3D images, and the demonstration of normal vessels and vascular lesions were particularly analyzed. At the same time, comparisons were made between the images of VR and SSD, MIP, and also between the diagnosis of VR-CTA and DSA or postoperative results. Results: In VR images, cerebral vessel routes and vessel cavities were showed clearly, while the relationship among vascular lesions, surrounding vessels, and neighboring structure was distinguished. 50 cases (80.6%) were found positive, 48 of which were correct and 2 were false-positive compared with DSA or postoperative results. The accurate rate of diagnosis was 96.0%. There was no obvious difference in showing the cerebral vessel among the images of VR, SSD and MIP (P > 0.25). Conclusion: Three-dimensional CT cerebral angiography with VR is a new noninvasive effective method. It can even partly replace the DSA. The 3D-images have the characteristics of showing the cerebral vascular cavity and overlapped vessels without cutting the skull

  15. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  16. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  17. Value of cardiac multislice spiral CT for the assessment of degenerative aortic stenosis: comparison with echocardiography

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Das, M.; Muehlenbruch, G.; Guenther, R.W.; Koos, R.; Sinha, A.M.; Stanzel, S.

    2004-01-01

    Objective: To non-invasively assess the severity of aortic valve stenosis (AS) by the determination of aortic valve calcification (AVC) using multislice spiral computed tomography (MSCT). Materials and Methods: Forty-one consecutive patients (17 male, 24 female, mean age 71.0±7.9 years) with a history of AS and an aortic valve area ≤2 cm 2 underwent retrospectively ECG-gated 4-slice MSCT and echocardiography. The AVCs were quantitatively assessed using the score described by Agatston as well as by calculating the calcium mass. The echocardiographically determined aortic valve area (AVA) and the severity of AS according to the ACC/AHA guidelines were compared to the degree of a aortic valve calcifications. Pearson's correlation coefficient, cut-off values, kappa test and F-test with post hoc Boneferroni t-tests were calculated. Results: Calcium scores were significantly higher in patients with severe AS, when compared to mild or moderate AS (p<0.001). In patients suffering from severe AS, the mean Agatston score was 4125.5±1168.9 (calcium mass 904.1±263.3) while in patients with moderate and mild AS the corresponding values were 1596.3±987.0 (319.1±208.3) and 785.9±390.1 (149.1±90.2), respectively. Pearson's correlation coefficients were r-=0.75 for the Agatston score and r=-0.72 for the calcium mass. There was a moderate agreement between severity of AS according to the ACC/AHA guidelines and the degree of AS determined from AVC scores with κ=0.6091 and κ=0.6985, respectively. Conclusion: Severe AS may be differentiated from moderate or mild AS using cardiac MSCT. Extensive calcifications of the aortic valve presenting with an Agatston-Score ≥2824 (calcium mass ≥611) indicate a severe AS and should be taken as an indication for further diagnostic workup. (orig.)

  18. Effect of imaging parameters of spiral CT scanning on image quality for the dental implants. Visual evaluation using a semi-anthropomorphic mandible phantom

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indou, Hiroko; Honda Eiichi

    2002-01-01

    The purpose of this study was to evaluate the effect of parameters of spiral CT scanning on the image quality required for the planning of dental implants operations. A semi-anthropomorphic mandible phantom which has artificial mandibular canals and teeth roots was used as a standard object for imaging. Spiral CT scans for the phantom settled in water phantom with diameters of 20 and 16 cm were performed. Visibility of the artificial mandibular canal made of a Teflon tube and gaps between tooth apex and canal in the mandibular phantom was evaluated for various combinations of the slice thickness, tables speeds, angles to the canal, and x-ray tube currents. Teeth roots were made of PVC (poly vinyl chloride). The artificial mandibular canal was clearly observed on the images of 1 mm slice thickness. At the same table speed of 2 mm /rotation, the images of thin slice (1 mm) were superior to that of thick slice (2 mm). The gap between teeth apex and canal was erroneously diagnosed on the images with table speeds of 3 mm/rotation. Horizontal scanning in parallel to the canal result in poor image quality for observation of mandibular canals because of the partial volume effect. A relatively high x-ray tube current (125 mA) at thin slice (1 mm) scanning was required for scanning the mandibular phantom in 20 cm water vessel. Spiral scanning with slice thickness of 1 mm and table speeds of 1 of 2 mm/rotation seemed to be suitable for dental implants. The result of this study suggested that diagnosis from two independent spiral scans with a different angle to the object was more accurate and more efficient than single spiral scanning. (author)

  19. The optimal dose of the contrast media for spiral CT portography

    International Nuclear Information System (INIS)

    Zhang Jiansheng; Xiao Peiyu; Meng Xiaochun; Xu Chuan

    2007-01-01

    Objective: To investigate the optimal dose of the contrast media in SCTP. Methods: 40 healthy patients were divided into 2 groups according to their body weight (20 cases in group A with weight below 60kg, 20 cases in group B with weight over 70kg). They all received 90ml contrast media at a rate of 4.0 ml/sec in the contrast-enhanced CT ex- amination. And non-cirrhosis cases, liver cirrhosis without ascites cases and liver cirrhosis with ascites cases were selected respectively, 60 patients in each group. Then, the patients of each group were randomly divided into 3 sub-groups, 20 cases in each of them, which respectively received 1.5ml/kg, 2.0ml/kg, 2.5ml/kg contrast media at a rate of 4.0 ml/sec in the contrast-enhanced CT examination. The effect of the dose of the contrast material on the imaging quality of portal vein system in patients with different weight and different state of illness was analyzed. Results: In 40 healthy patients, the density difference between portal vein and hepatic parenchyma was significantly higher in Group A than in Group B (P 0.05), and both of them showed significant difference while using 1.5ml/kg contrast media (P 0.05), and they both had significant difference when using 1.5ml/kg contrast media (P< 0.05). Besides these, the imaging quality of portal vein branches and collateral vessels were better in 2.0ml/kg group than others. Conclusion: The patient's body weight and the state of liver disease influenced the extent of portal vein enhancement. To calculate the dose of contrast media according to patient's weight is crucial for ensuring the imaging quality of portal vein system. 2.0ml/kg contrast media can provide a better effect. (authors)

  20. To evaluate vascular complications of transplant kidney examined by multislice spiral CT angiograph

    International Nuclear Information System (INIS)

    Peng Qian; Fan Miao; Luo Xiaomei

    2008-01-01

    Objective: To evaluate the value of multislice CT angiography (MSCTA) in vascular complications of transplant kidney. Methods: Six transplant kidneys were undergone enhanced MSCT scanning postoperation. MPR, CPR, VR and VP reformation were performed to observe transplant kidney's parenchyma, renal artery, and renal vein. To analysis all the reconstruction technique and find the advantage and shortage of them. Results: One case showed enhanced function of transplant kidney decreased. Vascular stenosis was found in one case and false aneurysm was found in another transplant kidney. Transplant kidney were enhanced normal in the left three cases. MPR couldn't reconstruct all the tortuous vessel of renal hilus in one plane. But all six cases could expose the vessel of renal hilus very clearly in coronal section and sagittal plane of CPR. Six cases of VR could observe the vessel direction and lesions outside vessel through rotate the reconstruction image. VP could see through inside the vessel of transplant kidney. Conclusion: MSCTA has an important role as an imaging technique to evaluate vascular complications of transplant kidney, it can replace DSA. (authors)

  1. Three phase spiral liver Scanning

    International Nuclear Information System (INIS)

    Kanyanja, T.A.

    2006-01-01

    The ability to perform rapid back-to-back spiral acquisitions is an important recent technical advantage of spiral CT. this allows imaging of the upper abdomen (liver) during peak arterial enhancement (arterial phase) and during peak hepatic parenchymal enhancement (portal venous phase). Breatheld spiral CT has completely replaced dynamic incremental CT for evaluation of the liver. in selected patients with hyper vascular metastasis (hepatoma, neuroendocrine tumors, renal cell carcinoma, etc.) a biphasic examination is performed with one spiral acquisition obtained during the hepatic arterial phase and a second acquisition during the portal venous phase

  2. The value of spiral CT and image post-processing in the evaluation of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Wang Jianwei; Wu Ning; Luo Dehong

    2001-01-01

    Objective: To access the value of the combination of axial image, MPR, and VE in the evaluation of laryngeal carcinoma involvement. Methods: Twenty patients with laryngeal carcinoma or hypopharyngeal carcinoma were prospectively studied by helical CT, and MPR and VE were subsequently done on the Voxel Q workstation. The axial images finding and the combined image findings of axial image, MPR, and VE were compared with the pathological results by using a predetermined checklist of 17 regions according to the TNM classification of malignant tumors (UICC and AJCC). The results were studied in a blind way. Results: In the evaluation of the neoplastic invasion of ventricular fold, vocal cord, the anterior commissure, subglottic region, thyroid cartilage, and tissue beyond the larynx, the combined image were better than axial image in sensitivity (100% vs 92.4%, P = 0.064), specificity (98.5% vs 89.5%, P = 0.028), and accuracy (99.2% vs 90.8%, P0.003). Neoplastic invasion of the arytenoid cartilage was present in 6 patients. The sensitivity and the specificity was 83.3% and 100% respectively when using the criteria of the arytenoid cartilage sclerosing combined with distortion, erosion or lysis. The specificity was only 57.1% when using the criteria of arytenoid cartilage sclerosing for judging parameter. The result was identical when assessing the arytenoid cartilage, PGS, and PES between the two groups. Conclusion: Axial image combined with subsequent MPR and VE could improve the diagnosis in the evaluation of the neoplastic invasion of ventricular fold, vocal cord, the anterior commissure, subglottic region, thyroid cartilage, and tissue beyond the larynx

  3. Multi-slice Fractional Ventilation Imaging in Large Animals with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Xin, Yi; Profka, Harrilla; Rajaei, Jennia; Kadlecek, Stephen; Ishii, Masaru; Rizi, Rahim R.

    2012-01-01

    Noninvasive assessment of regional lung ventilation is of critical importance in quantifying the severity of disease and evaluating response to therapy in many pulmonary diseases. This work presents for the first time the implementation of a hyperpolarized (HP) gas MRI technique for measuring whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the RF pulse decay effect from ventilatory signal build-up in the airways, regional distribution of flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no inter-scan time delay during a breath-hold at the tail-end of the ventilation sequence. Analysis was performed to assess the multi-slice ventilation model sensitivity to noise, oxygen and number of flip angle images. The optimal α value was determined based on minimizing the error in r estimation; αopt = 5–6° for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27±0.09, 0.35±0.06, 0.40±0.04 for ventral, middle and dorsal slices, respectively, (excluding conductive airways r > 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. Results demonstrate the feasibility of measurements of fractional ventilation in large species, and provides a platform to address technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of human beings. PMID:22290603

  4. The role of multislice spiral computed tomography in the diagnosis and management of acute facial trauma in patients with multiple injuries.

    Science.gov (United States)

    Nemsadze, G; Urushadze, O

    2011-11-01

    Using of mutislice spiral CT as first line examination for the diagnosis of Acute Facial trauma in the setting of Polytrauma reduces both: valuable time and cost of patient treatment. After a brief clinical examination, MDCT was performed depending on the area of injury, using a slice thickness of 0.65 mm. The obtained data were analyzed using 3D, MIP and Standard axial with Bone reconstruction protocols. 64 polytrauma patients were evaluated with both Anterior and Lateral craniography (plain skull X ray: AP and Lateral) and Multi Slice CT. Craniography detected only 18 cases of traumatic injuries of facial bones, but exact range of dislocation and accurate management plan could not be established. In the same 64 cases, Multislice CT revealed localization of all existed fractures, range of fragment dislocation, soft tissue damage and status of Paranasal sinus in 62 cases (96.8%). In two cases MS CT missed the facial fracture, in one case the examination was complicated because of bone thinness and numerous fracture fragments, in another multiple foreign body artifacts complicated the investigation. The study results show that, CT investigation based on our MDCT polytrauma protocol, detects all more or less serious facial bone injuries.

  5. Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Akram Al-Ibraheem

    2009-01-01

    Full Text Available 18F-FDG PET plays an increasing role in diagnosis and management planning of head and neck cancer. Hybrid PET/CT has promoted the field of molecular imaging in head and neck cancer. This modality is particular relevant in the head and neck region, given the complex anatomy and variable physiologic FDG uptake patterns. The vast majority of 18F-FDG PET and PET/CT applications in head and neck cancer related to head and neck squamous cell carcinoma. Clinical applications of 18F-FDG PET and PET/CT in head and neck cancer include diagnosis of distant metastases, identification of synchronous 2nd primaries, detection of carcinoma of unknown primary and detection of residual or recurrent disease. Emerging applications are precise delineation of the tumor volume for radiation treatment planning, monitoring treatment, and providing prognostic information. The clinical role of 18F-FDG PET/CT in N0 disease is limited which is in line with findings of other imaging modalities. MRI is usually used for T staging with an intense discussion concerning the preferable imaging modality for regional lymph node staging as PET/CT, MRI, and multi-slice spiral CT are all improving rapidly. Is this review, we summarize recent literature on 18F-FDG PET and PET/CT imaging of head and neck cancer.

  6. Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections

    Energy Technology Data Exchange (ETDEWEB)

    Remy-Jardin, Martine; Amara, Assia; Campistron, Philippe; Mastora, Ioana; Remy, Jacques [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France); Delannoy, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France)

    2003-05-01

    The aim of this study was to evaluate the accuracy of 3-mm-thick reconstructed sections in the diagnosis of bronchiectasis with multislice CT (MSCT). Forty consecutive patients suspected of bronchiectasis (23 females, 17 males; mean age 51 years) underwent MSCT of the entire thorax with a 4 x 1-mm collimation (120 kV, 0.5 s/rotation, 80 mAs/slice) and a pitch of 1.75. From each data set (mean z-axis coverage: 257 mm; mean duration: 21 s), two series of images were systematically generated: 1-mm (group 1) and 3-mm (group 2)-thick reconstructed scans. Both series of images were obtained at 10-mm intervals and reconstructed with a high-spatial-frequency algorithm. Two observers independently analyzed the presence of bronchiectasis and associated abnormalities in group-1 and group-2 lung images. No significant difference between group 1 and group 2 was found in: (a) the detection of bronchiectasis, identified in 24 patients (60%) in group 1 and in 23 patients (57.5%) in group 2 (p=0.08); (b) the evaluation of the extent of bronchiectasis, identifying focal bronchiectasis in 10 patients (25%) in group 1 and 7 patients (17.5%) in group 2 (p=0.39) and multifocal bronchiectasis in 16 patients (40%) in both groups; (c) the characterisation of bronchiectasis (cylindral bronchiectasis: group 1, n=24, 60%; group 2, n=21, 53%, p=0.08); varicose bronchiectasis: group 1, n=5, 12.5%; group 2, n=6, 15%, p=0.56; and cystic bronchiectasis: group 1, n=2, 5%; group 2, n=2, 5%. Apart from the identification of abnormal bronchial wall thickening (group 2, n=35, 87.5%, vs group 1, n=31, 77.5%, p<0.05), recognition of associated bronchopulmonary anomalies did not differ between the two groups. This study demonstrates a comparable accuracy of the 3- and 1-mm-thick reconstructed scans in the detection and characterization of bronchiectasis. These results suggest the potential usefulness of 3-mm-thick scans generated from 4 x 2.5-mm acquisitions in the screening of bronchiectasis, which would

  7. Spiral CT dual-phase scanning for hepatocellular carcinoma: comparison study on the peripheral enhancement and pathology

    International Nuclear Information System (INIS)

    Chen Wenxia; Min Pengqiu; Zhou Xiangping; Song Bin; Liu Yan; Shen Mingen; Li Zhenlin; Yang Min

    2002-01-01

    Objective: To compare the peripheral enhancement features of hepatocellular carcinoma (HCC) lesions in arterial and portal venous phases with histopathology, and to study the histopathologic bases of peripheral enhancement of the HCC lesions and how it affects the biologic behavior and prognosis. Methods: Forty-two histopathologically proven HCC patients were included. First, an unenhanced scanning covering the whole liver was done, and followed by arterial and portal venous phase scanning. The delay time was 20 sec and 60 sec after the injecting of contrast media. the slides of 5 μm thickness were stained with HE and the standard immunoperoxidase method using the polyclonal antibody of factor VIII-related antigen (F8RA). The pseudo capsule of the lesion, tumor invasion of the pseudo capsule, and the number of positive stained tumor vessels in the pseudo capsule were evaluated. Results: Among the 42 cases, in arterial phase, the pseudo capsule of the HCC lesions was demonstrated as hyper-or hypo-attenuation in 13 and 8 cases, respectively, and no marked pseudo capsule was perceived in 21 cases. In portal venous phase, hyper-attenuated pseudo capsule was shown in 27 cases, hypo-attenuated pseudo capsule in 2 cases, and no pseudo capsule in 13 cases. On CT scans, daughter foci were showed in 14 cases, in which 9 cases were single and 5 of 42 patients, and tumor cells invaded the pseudo capsule in 16 caes among these cases. F8RA immunohistochemical staining showed that the pseudo capsule contained rich positive staining neo-vascular structure in 15 of 25 cases, and the other 10 cases had thick pseudo capsule but few neo-vascular structure. HE staining showed no marked pseudo capsule in 17 cases, in which 8 cases exhibited no clear border between the tumor tissue and liver parenchyma. Conclusion: The peripheral enhancement features of HCC on spiral CT dural-phase scanning could reflect the histopathologic characteristics and predict the biologic behavior and prognosis

  8. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  9. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography

    International Nuclear Information System (INIS)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J.; Stahel, P.F.; Ertel, W.

    2004-01-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  10. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction; Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter

    Energy Technology Data Exchange (ETDEWEB)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E. [Abt. Roentgendiagnostik I, Georg-August-Univ. Goettingen (Germany); Merten, H.A. [Abt. fuer Mund-, Kiefer- und Gesichtschirurgie, Georg-August-Univ. Goettingen (Germany)

    2002-07-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [German] Zielsetzung: Verbesserung der Aufnahme- und Rekonstruktionsparameter in der Mehrschicht Spiral-CT (MSCT) zur Untersuchung des knoechernen Mittelgesichtes in verschiedenen Ebenen. Material und Methode: Ein anthropomorphes Schaedel-Phantom wurde in axialer Schichtfuehrung mit einem MSCT untersucht, wobei die Kollimation (1,25 - 2,5 mm), der Tischvorschubfaktor (Pitch 3 - 6) und der Roehrenstrom (20 - 200 mA) systematisch variiert wurden. Aus den Volumendatensaetzen wurden jeweils koronare und parasagittale Sekundaerreformationen mit unterschiedlichen

  11. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai; Ma, Rui; Wang, Li Jun [Dept. of Radiology, Baotou Central Hospital, Baotou (China); Li, Li Gang; Chen, Jiu Hong [CT BM Clinic Marketing, Siemens Healthcare, Beijing (China)

    2012-11-15

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 {+-} 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 {+-} 0.306 [group A] vs. 1.084 {+-} 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 {+-} 0.16 mSv in group A and 7.1 {+-} 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  12. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    International Nuclear Information System (INIS)

    Sun, Kai; Ma, Rui; Wang, Li Jun; Li, Li Gang; Chen, Jiu Hong

    2012-01-01

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  13. Accuracy of spiral CT and 3D reconstruction in the detection of acute pulmonary embolism - development of an animal model using porcine lungs and technical specimens. Development of an animal model using porcine lungs and technical specimens

    International Nuclear Information System (INIS)

    Ries, B.G.; Kauczor, H.U.; Thelen, M.; Konerding, M.A.

    2001-01-01

    Purpose: To develop a model for simulation the CT morphologic situation of acute pulmonary embolism, to evaluate the accuracy of spiral CT and 3D reconstruction in the detection of artificial emboli and to investigate the influence of the orientation of emboli depending on z-axis orientation. Materials and Methods: Standardized artificial emboli made of wax and of defined size and shape were positioned into the pulmonary arteries of porcine lungs. Castings of the embolized pulmonary arterial trees were made by injection of a special opaque resin. After performance of spiral CT the data sets of the emboli and the pulmonary arteries were post-processed. The 3D segmentations were compared with the anatomic preparation to evaluate the accuracy of spiral CT/3D reconstruction-technique. Technical specimens simulating CT-morphology of acute embolized vessels underwent spiral CT in six different positions with respect to the z-axis. The CT data were reconstructed using a standardized and a contrastadapted method with interactive correction. The 3D emboli were analysed under qualitative aspects, and measurements of their extent were done. Results: In nearly 91%, there was complete agreement between CT and the corresponding findings at the anatomical preparation. Measurements of the 3D reconstructed technical specimens showed discrepancies of shape and size in dependence of the size of the original preparation, orientation and reconstruction technique. Overestimation up to 4 mm and underestimation to 2,2 mm were observed. Measurements of preparations with heights from 14 to 26 mm showed variances of ±1,5 mm (∝6-11%). Conclusion: The presented models are suitable to simulate CT morphology of acute pulmonary embolism under ex-vivo conditions. Accuracy in the detection of artificial emboli using spiral CT/3D reconstruction is affected by localization, size and orientation of the emboli and the reconstruction technique. (orig.) [de

  14. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  15. Angiogenesis in hepatocellular carcinoma: correlation of single-level dynamic spiral CT scans in arterial phase and expression of α-smooth muscle actin

    International Nuclear Information System (INIS)

    Liu Yan; Min Pengqiu; Chen Weixia; Zhang Lin

    2005-01-01

    Objective: To investigate the correlation between the single-level dynamic spiral CT scans (SDCT) of hepatocellular carcinoma (HCC) in arterial phase (AP) and the immunohistochemistry expression of α-smooth muscle actin (ASMA). Methods: 33 cases of suspected HCC undergoing spiral CT plain scan of the whole liver, the single-level dynamic scan of the target level of lesion in AP and finally the whole liver scan in portal-venous phase before operations and proved after were included into the study. After the SDCT, a time-density curve (T-DC) was drawn according to the density change of the region of interest (ROI) of the tumor parenchyma with some parameters calculated, and signs of enhancement evaluated. Slices of post-operation specimen underwent hemotoxylin-eosin (HE) and ASMA immunohistochemistry staining. Then the slices were evaluated with emphases on the ASMA-positive neovasculatures in the parenchyma and mesenchyma of carcinomas, and the average count in a low microscopic field (x 100) was recorded (5 low microscopic field were observed and then an average was calculated.). Finally the immunohistochemistry and histologic results were correlated with image findings. Results: According to the PV of the tumor parenchyma, T-DC was divided into type I, II and III in which the criteria were PV>80, 40 HU< PV< 80 HU and PV<40 HU respectively. In the 33 cases, type I, II and III of T-DC were 3, 17 and 13 cases with PV of 103.30, 57.65 and 33.55 HU respectively. In ASMA immunohistochemistry study, ASMA-positive neovasculatures were devided into type A with a thick wall and B with a thin wall. The mean count of neovasculatures of tumor parenchyma in type I, II and III of T-DC were 10, 4.59 and 1 respectively. Statistically, different types of T-DC were significantly correlated with the count of neovasculatures in the parenchyma of carcinomas (r=-0.567, P<0.01). Homogeneous and inhomogeneous enhancement of carcinomas during SDCT in AP were correlated with the

  16. Multi-slice MRI reveals heterogeneity in disease distribution along the length of muscle in Duchenne muscular dystrophy.

    Science.gov (United States)

    Chrzanowski, Stephen M; Baligand, Celine; Willcocks, Rebecca J; Deol, Jasjit; Schmalfuss, Ilona; Lott, Donovan J; Daniels, Michael J; Senesac, Claudia; Walter, Glenn A; Vandenborne, Krista

    2017-09-01

    Duchenne muscular dystrophy (DMD) causes progressive pathologic changes to muscle secondary to a cascade of inflammation, lipid deposition, and fibrosis. Clinically, this manifests as progressive weakness, functional loss, and premature mortality. Though insult to whole muscle groups is well established, less is known about the relationship between intramuscular pathology and function. Differences of intramuscular heterogeneity across muscle length were assessed using an ordinal MRI grading scale in lower leg muscles of boys with DMD and correlated to patient's functional status. Cross sectional T 1 weighted MRI images with fat suppression were obtained from ambulatory boys with DMD. Six muscles (tibialis anterior, extensor digitorum longus, peroneus, soleus, medial and lateral gastrocnemii) were graded using an ordinal grading scale over 5 slice sections along the lower leg length. The scores from each slice were combined and results were compared to global motor function and age. Statistically greater differences of involvement were observed at the proximal ends of muscle compared to the midbellies. Multi-slice assessment correlated significantly to age and the Vignos functional scale, whereas single-slice assessment correlated to the Vignos functional scale only. Lastly, differential disease involvement of whole muscle groups and intramuscular heterogeneity were observed amongst similar age subjects. A multi-slice ordinal MRI grading scale revealed that muscles are not uniformly affected, with more advanced disease visible near the tendons in a primarily ambulatory population with DMD. A geographically comprehensive evaluation of the heterogeneously affected muscle in boys with DMD may more accurately assess disease involvement.

  17. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    Science.gov (United States)

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Intravenous spiral CT angiography for assessment before orthotopic liver transplantation: Comparison between tomography, MIP, 3-dimensional surface imaging and intraarterial DSA

    International Nuclear Information System (INIS)

    Hidajat, N.; Vogl, T.J.; Moeller, M.; Bechstein, W.O.; Felix, R.

    1996-01-01

    Purpose: To analyse the efficacy of intravenous spiral CT angiography (SCTA) for the evaluation before orthotopic liver transplantation (oLT) compared with DSA. Methods: Spiral CT was performed on 31 potential recipients of a liver graft in order to examine hepatic vessels, coeliac axis, splenic artery and superior mesenteric artery. The arterial vessels were reconstructed in 'Maximum Intensity Projection (MIP)' and 'Shaded Surface Display (SSD)'-technique. The axial images, MIP and SSD were compared in 25 patients with DSA with regard to the visualisation of the vascular anatomy, detectability of stenosis and vascular diameters. Results: The type of arterial liver supply could be determined via SCTA in all patients. Stenosis of the coeliac axis was seen in ten patients on the DSA, MIP and SSD and in eight patients on the axial images. Occlusion of the hepatic artery was clearly visualised in two patients on the DSA, axial images and MIP and in one patient on the SSD. There was no false positive diagnosis with SCTA. SSD was seen as the best technique to visualise the vessels without overshadowing. There were no significant differences between the diamters measured from the axial images, MIP and SSD images in transversal direction and the DSA images (p>0.05). Conclusion: SCTA is a greatly promising method for the imaging of vessels supplying the liver before oLT, and may convey more diagnostic information than DSA. (orig.) [de

  19. Acute and chronic myocardial infarction in a pig model: Utility of multi-slice cardiac computed tomography in assessing myocardial viability and infarct parameters

    International Nuclear Information System (INIS)

    Qu Xinkai; Fang Weiyi; Ye Jianding; Koh, Angela S.; Xu Yingjia; Guan Shaofeng; Li Ruogu; Shen Yan

    2012-01-01

    Objectives: The aim of this study was to determine the feasibility of multi-slice computed tomography (MSCT) biphasic imaging in assessing myocardial viability and infarct parameters in both acutely and chronically infarcted pig models. Materials and methods: Seven pigs underwent ligation of the distal left anterior descending artery. Imaging was performed on the day of infarction and 3 months post-infarct, with contrast infusion followed by MSCT scan acquisition at different time-points. Left ventricular ejection fractions (LVEFs) were obtained by left ventriculography (LVG) after 3 months. Infarcted locations found using MSCT were compared with those obtained using SPECT. Infarcted areas were also analysed histopathologically and compared with the findings from MSCT. Results: Chronic phase images had perfusion defects with lower CT values relative to normal myocardium (43 ± 10 HU vs. 156 ± 13 HU, p = 0.001) on the early images but no residual defects on delayed images. However, we found hyperenhancing regions on delayed images (244 ± 20 HU vs. 121 ± 25 HU, p = 0.001), and good correlation between MSCT- and LVG-derived LVEFs (60.56 ± 7.56%). The areas identified by MSCT corresponded to the location of 201 Tl SPECT-/pathologic staining-derived regions in all models. Infarct size was in good agreement with MSCT and pathological analyses of chronic phase models. Conclusions: Necrotic myocardium in different stages after infarction could be qualitatively and quantitatively assessed using MSCT biphasic imaging, as could the status of microcirculation formation. MSCT-measured LVEFs matched well with other modalities, and hence MSCT is a useful tool in assessing post-infarct cardiac function.

  20. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    International Nuclear Information System (INIS)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H.

    2009-01-01

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6≤pitch≤3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  1. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. No significant differences in quantitative measures of image quality were found between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6 pitch 3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch = 3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom

  2. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H. [Siemens Healthcare, Computed Tomography, 91301 Forchheim, Germany and Department of Diagnostic Radiology, Eberhard-Karls-Universitaet, 72076 Tuebingen (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Siemens Healthcare, Computed Tomography, 91301 Forchheim (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2009-12-15

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  3. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  4. Visualisation of animal anatomy using MRI and CT

    DEFF Research Database (Denmark)

    Lauridsen, Henrik; Hansen, Kasper; Pedersen, Michael

    imaging (MRI) and CT. Various species (tarantula, horseshoe crab, carp, haddock, lungfish, axolotl) were subjected to multi-slice MRI and CT protocols to produce 2D images of body slices, followed by volume rendering producing 3D digital models of animal anatomy with applications for visualising specific...

  5. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  6. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

    International Nuclear Information System (INIS)

    Jarry, G; De Marco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-01-01

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  7. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    International Nuclear Information System (INIS)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M.; Wagstaff, Anne W.; Smeltzer, Matthew P.; Krafft, Axel J.; Hankins, Jane S.

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  8. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Wagstaff, Anne W. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Rhodes College, Memphis, TN (United States); University of Alabama at Birmingham School of Medicine, Birmingham, AL (United States); Smeltzer, Matthew P. [St. Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); University of Memphis, Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, Memphis, TN (United States); Krafft, Axel J. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); University Hospital Center Freiburg, Department of Radiology, Freiburg (Germany); Hankins, Jane S. [St. Jude Children' s Research Hospital, Department of Hematology, Memphis, TN (United States)

    2017-01-15

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  9. Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT

    International Nuclear Information System (INIS)

    Kotsianos, D.; Rock, C.; Wirth, S.; Linsenmaier, U.; Brandl, R.; Fischer, T.; Pfeifer, K.J.; Reiser, M.; Euler, E.; Mutschler, W.

    2002-01-01

    Purpose: To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Method: Human knee specimens (n=22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Mueller AO classification. To confirm the results, the specimens were finally surgically dissected. Results: 97% of the tibial condylar fractures were easily seen and correctly classified according to the Mueller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. (orig.) [de

  10. Logarithmic Spiral

    Indian Academy of Sciences (India)

    Switzerland) even today can see the. Archimedian spiral and the inscription under it on the tombstone of Jacob Bernoulli 1. Logarithmic Spiral in Nature. Apart from logarithmic spiral no other curve seems to have attracted the attention of scientists, ...

  11. Colour-coded three-dimensional reconstruction from spiral CT data sets: Improvement from the physical point of view

    International Nuclear Information System (INIS)

    Wunderlich, A.P.; Lenz, M.; Kirsten, R.; Gerhardt, P.

    1993-01-01

    This paper demonstrates the possibility of improving the spatial depth impression of colour-coded three-dimensional reconstructions by modulation of colour saturation. Patients were observed with spiral computed tomography (slice thickness 10 mm, table feed 10 mm/s, reconstruction of overlapping axial images at 2 mm increment). Interesting anatomical and pathological objects (vessels, organs, tumours, metastases) were segmented, colour-coded, and reconstructed three-dimensionally. Spatial depth impression of the coloured objects could be improved by modulating not only the brightness, but also the colour saturation. (orig.) [de

  12. CT technology update

    International Nuclear Information System (INIS)

    Edyvean, S.

    2004-01-01

    Full text: The capabilities of CT scanning as a diagnostic imaging medium increased dramatically with the introduction of four slice scanners in the second half of 1998. The ability to acquire four sets of scan projection data per revolution of the scanner gantry can be exploited by imaging a scan volume faster, or with greater z-axis resolution than a single slice scanner, or scanning larger volumes in the same total time. This has improved the quality of a number of clinical applications, as well as enabling new techniques that were not previously possible. This workshop will review the advances in CT scanning that have lead to modern multi-slice scanning. The operation of scanners will be explored looking at the hardware required and the changes in reconstruction techniques necessary with the higher number of imaged slices. The advantages and disadvantages of multi-slice scanners over their single-slice equivalents will be investigated, and image quality and dose issues will be discussed. An overview of the clinical applications that benefit from multi-slice technology will be given. The talk will end with a glimpse into the future where we have 64 and 256 slice, as well as flat panel, systems currently being trialled. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  13. Added diagnostic benefit of 16-row whole-body spiral CT in patients with multiple trauma differentiated by region and injury severity according to the ATLS registered concept

    International Nuclear Information System (INIS)

    Maurer, M.H.; Knopke, S.; Schroeder, R.J.

    2008-01-01

    Purpose: to determine the added diagnostic benefit of using MS-CT in multiple trauma patients differentiated by severity of injury and affected body region. Materials and methods: a retrospective analysis was performed of the 16-row whole-body spiral CT findings in 275 multiple trauma patients (73% men, 27% women; age 39.6 ± 18.9 years) with regard to additional findings and new findings obtained with CT compared to the findings obtained by conventional projection radiography and abdominal ultrasound in the emergency room. The additional and new findings were differentiated by body region (head, face, chest, pelvis, abdomen, spine) and the degree of severity according to the three classes of injuries distinguished by the ATLS registered concept (class 1: simple injury, class 2: potentially life threatening, class 3: immediately life threatening). Results: a total of 921 additional findings (findings potentially relevant for further diagnosis and therapy in addition to the findings obtained by conventional radiography or ultrasound) were obtained by MS-CT in all patients. The distribution by number of patients and body region was as follows: 22 neck, 76 face, 125 chest, 112 abdomen, 50 pelvis, and 91 spine. Most additional findings were categorized as potentially life threatening (ATLS class 2). In addition, there were 439 completely new findings, involving the head in 128 patients (mostly ATLS class 3), the face in 18, the chest in 47, the abdomen in 26, and the spine in 9 patients. Most new findings involving the face, abdomen, and spine were ATLS class 2 injuries. (orig.)

  14. Three-dimensional display of the pelvic viscera using multi-sliced MR images

    International Nuclear Information System (INIS)

    Ueno, Shigeru; Suto, Yasuzo.

    1995-01-01

    Accurate reconstruction of the pelvic structure is the most important factor to obtain desirable results after anorectal surgery. Preoperative evaluation of the anatomy is indispensable for choosing an appropriate operative method in each case. To facilitate the preoperative evaluation, three dimensional images of the pelvic structure of patients with anorectal malformations were constructed by computer graphics based upon two dimensional images obtained from MR-CT. Graphic data from MR images were transferred to a graphic work station. The anorectum, bladder and sphincter musculature were displayed three-dimensionally after segmenting these organs by (1) manually regioning the area containing the specific organ and (2) thresholding the area by the T 1 intensity level. The anatomy of each type of anomaly is easily recognized by the 3-D visualization of pelvic viscera and sphincter musculature with emphasis on position and shape of the musculature although there are some difficulties to visualize soft tissue organs. The advanced programs could show the graphic images from any desirable angle quickly enough to be helpful for the simulation of the surgery. Three-dimensional display can be very useful for better understanding of each anomaly and determining the operative method prior to surgery. (author)

  15. Mid-term results of off-pump coronary artery bypass grafting assessed by multi-slice computed tomography

    International Nuclear Information System (INIS)

    Yoshida, Seijiro; Nitta, Yoshio; Oda, Katsuhiko

    2004-01-01

    Off-pump coronary artery bypass (OPCAB) has recently increased in popularity, but the long-term results are still unknown. We evaluated the mid-term results of OPCAB surgery using multi-slice computed tomography (MSCT), which is a non-invasive postoperative evaluation method. Thirty-one consecutive patients who underwent OPCAB surgery at least 2 years prior to the study were selected. The age was 50 to 79 years (66.9±6.5) and the ratio of men to women was 26:5. Coronary angiography was performed in all patients at 2 weeks postoperatively. The follow-up was complete, and mean follow-up was 30.9 months. There were no hospital deaths and 1 non-cardiac late death. The graft patency rate in coronary angiography was left internal thoracic artery (LITA) 30/30 (100%), right internal thoracic artery (RITA) 2/2 (100%), radial artery (RA) 14/15 (93%), saphenous vein graft (SVG) 15/17 (88%). No graft became occluded on MSCT study and all patients have been angina-free during the follow-up period. We suggest that OPCAB is feasible in most patients with good patency and low mortality. MSCT is an effective follow up method for the morphological findings and noninvasive quantitative evaluation of the bypass grafts. (author)

  16. Aortic non communicating dissections. A study with helical CT; Studio dell'ematoma intramurale aortico. Aspetti con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G. [Bari Univ., Bari (Italy). Dipt. di Medicina Interna e Medicina Pubblica, Sez. di Diagnostica per Immagini; Scialpi, M. [Ospedale SS. Annunziata, Taranto (Italy); D' Agostino, D.; De Luca Tupputi Schinosa, L. [Bari Univ., Bari (Italy). Dipt. Emergenze Trapianto d' Organo, Sez. di Cardiochirurgia

    2000-09-01

    confused with aortic dissection. The imaging techniques (TEE, CT, MRI) have an important role in the final diagnosis of aortic hematoma. Presently Helical CT and MR angiography are the main tools in the early diagnosis of this condition before the development of complications. In this experience helical CT, before and after the administration of contrast material, was accurate in identifying the hematoma localization and extension. [Italian] Tale studio ha lo scopo di valutare con tecnica TC spirale gli aspetti semeiologici dell'ematoma intramurale dell'aorta e sottolineare il ruolo diagnostico decisivo di tale metodica nello studio di pazienti con quadro clinico acuto sospetto per dissezione aortica. E' stato condotto uno studio retrospettivo (dal 1995 al 1999) sulle immagini di 396 pazienti che avevano eseguito un esame TC in regime d'urgenza per sospetta dissezione aortica. Solo 18 pazienti (6 femmine, 12 maschi) presentavano aspetti tomodensitometrici caratteristici per ematoma intramurale aortico. Gli esami sono stati condotti tutti con TC spirale utilizzando i seguenti parametri: spessore dello strato 10 mm, image index 10, passo della spirale 1,5 mm, algoritmo standard con un minimo di 130 kV e 125 mA. Gli esami sono stati condotti prima e dopo iniezione di 130 ml di mdc in bolo rapido e ricercando i seguenti parametri: sede ed estensione longitudinale dell'ematoma spessore e densita' della parte aortica, presenza e localizzazione delle caclificazioni intimali, regolarita' del lume vero, presenza di emomediastino e/o emotorace. In tutti i 18 pazienti (8 di tipo A e 10 di tipo B) e' stato osservato ispessimento circoscritto parietale tipicamente iperdenso nelle scansioni di base e ipodenso in quelle dopo mdc. In 14/18 pazienti l'ispessimento assumeva disposizione eccentrica, in solo 4/18 era concentrico; in tutti i casi l'ispessimento e' risultato maggiore di 4 mm. In 18/18 pazienti sono state riscontrate

  17. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  18. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT; Screening della neoplasia polmonare con TC spirale a bassa dose: risultati di uno studio pilota triennale e disegno dello studio clinico randomizzato Italung-CT

    Energy Technology Data Exchange (ETDEWEB)

    Picozzi, Giulia [Firenze Univ., Firenze (Italy). Radiodiagnostica I-Dipartimento di Fisiopatologia Clinica; Paci, Enrico [Azienda Ospedaliera Universitaria di Careggi, Firenze (Italy). Unita' di Epidemiologia Clinica e Descrittiva Centro per lo Studio e la Prevenzione Oncologica; Lopes Pegna, Andrea [Azienda Ospedaliera Universitaria di Careggi, Firenze (Italy). U.O. Pneumologia] [and others

    2005-02-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64{+-}4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was <5mm in diameter in 20 subjects. 10 of whom showed the nodule at the baseline test. Forty-five subjects (75%) completed the first annual test and 42 (70%) the second annual test. One (1.6%) prevalent lung cancer (adenosquamous carcinoma) and one (2.2%) incident lung cancer (small cell cancer at the first annual examination) were observed, as well as pulmonary localisation of Hodgkin's lymphoma (at the second annual test). In addition, one subject underwent lung surgery for a chondromatous hamartoma. Conclusions: The results of the pilot study are substantially in line with those of other observational studies of greater sample size. This justifies optimism about the reliability of the results in the screened arm of the Italung Ct trial which hast just began. [Italian] Scopo: Riportare i risultati di uno studio pilota osservazionale di screening della neoplasia polmonare con TC a bassa dose della durata di tre anni e presentare il disegno dello studio clinico randomizzato Italung-CT. Materiale e metodi: Sessanta (47 uomini e 13 donne, eta' media 64{+-}4,5 anni) forti fumatori (almeno 20 pacchetti/anno) sono stati sottoposti ad un esame basale e a due controlli annuali con TC single o

  19. Application of multislice spiral CT (MSCT) in multiple injured patients and its effect on diagnostic and therapeutic algorithms

    International Nuclear Information System (INIS)

    Boehm, T.; Alkadhi, H.; Schertler, T.; Baumert, B.; Roos, J.; Marincek, B.; Wildermuth, S.

    2004-01-01

    The initial diagnostic work-up of trauma victims with multiple injuries is currently a combination of conventional radiography (CR), ultrasound (US), and computed tomography (CT). This article reviews the diagnostic quality of the different imaging modalities regarding detection and classification of injuries. CT performs better than US in detecting traumatic lesions of abdominal parenchymal organs. Furthermore, CT is better than CR in detecting therapeutically relevant chest and bone injuries. MSCT may replace CR and US under the condition that it is faster than or at least as fast as the conventional approach to diagnose lite threatening injuries. This can be achieved only by changing the work-flo