WorldWideScience

Sample records for multi-isotope imaging mass

  1. Quantitating subcellular metabolism with multi-isotope imaging mass spectrometry

    OpenAIRE

    Steinhauser, Matthew L.; Bailey, Andrew; Senyo, Samuel E.; Guillermier, Christelle; Perlstein, Todd S.; Gould, Alex P.; Lee, Richard T.; Lechene, Claude P.

    2012-01-01

    Mass spectrometry with stable isotope labels has been seminal in discovering the dynamic state of living matter 1,2 but is limited to bulk tissues or cells. We developed multi-isotope imaging mass spectrometry (MIMS) that allowed us to view and measure stable isotope incorporation with sub-micron resolution 3,4 . Here we apply MIMS to diverse organisms, including Drosophila, mice, and humans. We test the “immortal strand hypothesis,” which predicts that during asymmetric stem cell division ch...

  2. Quantitating subcellular metabolism with multi-isotope imaging mass spectrometry

    Science.gov (United States)

    Steinhauser, Matthew L.; Bailey, Andrew; Senyo, Samuel E.; Guillermier, Christelle; Perlstein, Todd S.; Gould, Alex P.; Lee, Richard T.; Lechene, Claude P.

    2011-01-01

    Mass spectrometry with stable isotope labels has been seminal in discovering the dynamic state of living matter1,2 but is limited to bulk tissues or cells. We developed multi-isotope imaging mass spectrometry (MIMS) that allowed us to view and measure stable isotope incorporation with sub-micron resolution3,4. Here we apply MIMS to diverse organisms, including Drosophila, mice, and humans. We test the “immortal strand hypothesis,” which predicts that during asymmetric stem cell division chromosomes containing older template DNA are segregated to the daughter destined to remain a stem cell, thus insuring lifetime genetic stability. After labeling mice with 15N-thymidine from gestation through post-natal week 8, we find no 15N label retention by dividing small intestinal crypt cells after 4wk chase. In adult mice administered 15N-thymidine pulse-chase, we find that proliferating crypt cells dilute label consistent with random strand segregation. We demonstrate the broad utility of MIMS with proof-of-principle studies of lipid turnover in Drosophila and translation to the human hematopoietic system. These studies show that MIMS provides high-resolution quantitation of stable isotope labels that cannot be obtained using other techniques and that is broadly applicable to biological and medical research. PMID:22246326

  3. Quantitative imaging of subcellular metabolism with stable isotopes and multi-isotope imaging mass spectrometry

    Science.gov (United States)

    Steinhauser, Matthew L.; Lechene, Claude P.

    2014-01-01

    Multi-isotope imaging mass spectrometry (MIMS) is the quantitative imaging of stable isotope labels in cells with a new type of secondary ion mass spectrometer (NanoSIMS). The power of the methodology is attributable to (i) the immense advantage of using non-toxic stable isotope labels, (ii) high resolution imaging that approaches the resolution of usual transmission electron microscopy and (iii) the precise quantification of label down to 1 part-per-million and spanning several orders of magnitude. Here we review the basic elements of MIMS and describe new applications of MIMS to the quantitative study of metabolic processes including protein and nucleic acid synthesis in model organisms ranging from microbes to humans. PMID:23660233

  4. Multi-isotope imaging mass spectrometry quantifies stem cell division and metabolism.

    Science.gov (United States)

    Steinhauser, Matthew L; Bailey, Andrew P; Senyo, Samuel E; Guillermier, Christelle; Perlstein, Todd S; Gould, Alex P; Lee, Richard T; Lechene, Claude P

    2012-01-15

    Mass spectrometry with stable isotope labels has been seminal in discovering the dynamic state of living matter, but is limited to bulk tissues or cells. We developed multi-isotope imaging mass spectrometry (MIMS) that allowed us to view and measure stable isotope incorporation with submicrometre resolution. Here we apply MIMS to diverse organisms, including Drosophila, mice and humans. We test the 'immortal strand hypothesis', which predicts that during asymmetric stem cell division chromosomes containing older template DNA are segregated to the daughter destined to remain a stem cell, thus insuring lifetime genetic stability. After labelling mice with (15)N-thymidine from gestation until post-natal week 8, we find no (15)N label retention by dividing small intestinal crypt cells after a four-week chase. In adult mice administered (15)N-thymidine pulse-chase, we find that proliferating crypt cells dilute the (15)N label, consistent with random strand segregation. We demonstrate the broad utility of MIMS with proof-of-principle studies of lipid turnover in Drosophila and translation to the human haematopoietic system. These studies show that MIMS provides high-resolution quantification of stable isotope labels that cannot be obtained using other techniques and that is broadly applicable to biological and medical research.

  5. 3D Multi-isotope Imaging Mass Spectrometry Reveals Penetration of 18O-Trehalose in Mouse Sperm Nucleus

    OpenAIRE

    Lechene, Claude P.; Lee, Gloria Y.; Poczatek, J. Collin; Toner, Mehmet; Biggers, John D.

    2012-01-01

    The prevalence of genetically engineered mice in medical research has led to ever increasing storage costs. Trehalose has a significant beneficial effect in preserving the developmental potential of mouse sperm following partial desiccation and storage at temperatures above freezing. Using multi-isotope imaging mass spectrometry, we are able to image and measure trehalose in individual spermatozoa. We provide the first evidence that trehalose penetrates the nucleus of a mammalian cell, permit...

  6. 3D multi-isotope imaging mass spectrometry reveals penetration of 18O-trehalose in mouse sperm nucleus.

    Directory of Open Access Journals (Sweden)

    Claude P Lechene

    Full Text Available The prevalence of genetically engineered mice in medical research has led to ever increasing storage costs. Trehalose has a significant beneficial effect in preserving the developmental potential of mouse sperm following partial desiccation and storage at temperatures above freezing. Using multi-isotope imaging mass spectrometry, we are able to image and measure trehalose in individual spermatozoa. We provide the first evidence that trehalose penetrates the nucleus of a mammalian cell, permitting tolerance to desiccation. These results have broad implications for long-term storage of mammalian cells.

  7. 3D multi-isotope imaging mass spectrometry reveals penetration of 18O-trehalose in mouse sperm nucleus.

    Science.gov (United States)

    Lechene, Claude P; Lee, Gloria Y; Poczatek, J Collin; Toner, Mehmet; Biggers, John D

    2012-01-01

    The prevalence of genetically engineered mice in medical research has led to ever increasing storage costs. Trehalose has a significant beneficial effect in preserving the developmental potential of mouse sperm following partial desiccation and storage at temperatures above freezing. Using multi-isotope imaging mass spectrometry, we are able to image and measure trehalose in individual spermatozoa. We provide the first evidence that trehalose penetrates the nucleus of a mammalian cell, permitting tolerance to desiccation. These results have broad implications for long-term storage of mammalian cells.

  8. Segmentation of Multi-Isotope Imaging Mass Spectrometry Data for Semi-Automatic Detection of Regions of Interest

    Science.gov (United States)

    Poczatek, J. Collin; Turck, Christoph W.; Lechene, Claude

    2012-01-01

    Multi-isotope imaging mass spectrometry (MIMS) associates secondary ion mass spectrometry (SIMS) with detection of several atomic masses, the use of stable isotopes as labels, and affiliated quantitative image-analysis software. By associating image and measure, MIMS allows one to obtain quantitative information about biological processes in sub-cellular domains. MIMS can be applied to a wide range of biomedical problems, in particular metabolism and cell fate [1], [2], [3]. In order to obtain morphologically pertinent data from MIMS images, we have to define regions of interest (ROIs). ROIs are drawn by hand, a tedious and time-consuming process. We have developed and successfully applied a support vector machine (SVM) for segmentation of MIMS images that allows fast, semi-automatic boundary detection of regions of interests. Using the SVM, high-quality ROIs (as compared to an expert's manual delineation) were obtained for 2 types of images derived from unrelated data sets. This automation simplifies, accelerates and improves the post-processing analysis of MIMS images. This approach has been integrated into “Open MIMS,” an ImageJ-plugin for comprehensive analysis of MIMS images that is available online at http://www.nrims.hms.harvard.edu/NRIMS_ImageJ.php. PMID:22347386

  9. The effects of the 'key' molar mass on the design of a cascade handling a multi-isotopic mixture

    International Nuclear Information System (INIS)

    Raichura, R.C.; Al-Janabi, M.A.M.

    1991-01-01

    The parameters required for describing the characteristics of separating units and cascades handling a multi-isotope mixture are first reviewed from previous work and then expressed in terms of a newly defined parameter called the 'Key' molar mass. The effects of the latter on the operating and economic parameters of a gas centrifuge cascade handling a multi-isotopic mixture are studied. Only cascades of the 'primitive' type, i.e. those in which the feed of a stage is made up of the light and heavy fractions of neighbouring stages, are considered. The costs incurred in obtaining outputs with specified concentrations are then discussed. (author)

  10. Mass preserving image registration

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2010-01-01

    The paper presents results the mass preserving image registration method in the Evaluation of Methods for Pulmonary Image Registration 2010 (EMPIRE10) Challenge. The mass preserving image registration algorithm was applied to the 20 image pairs. Registration was evaluated using four different...

  11. Multi-isotopic determination of plutonium (239Pu, 240Pu, 241Pu and 242Pu) in marine sediments using sector-field inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Donard, O F X; Bruneau, F; Moldovan, M; Garraud, H; Epov, V N; Boust, D

    2007-03-28

    Among the transuranic elements present in the environment, plutonium isotopes are mainly attached to particles, and therefore they present a great interest for the study and modelling of particle transport in the marine environment. Except in the close vicinity of industrial sources, plutonium concentration in marine sediments is very low (from 10(-4) ng kg(-1) for (241)Pu to 10 ng kg(-1) for (239)Pu), and therefore the measurement of (238)Pu, (239)Pu, (240)Pu, (241)Pu and (242)Pu in sediments at such concentration level requires the use of very sensitive techniques. Moreover, sediment matrix contains huge amounts of mineral species, uranium and organic substances that must be removed before the determination of plutonium isotopes. Hence, an efficient sample preparation step is necessary prior to analysis. Within this work, a chemical procedure for the extraction, purification and pre-concentration of plutonium from marine sediments prior to sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) analysis has been optimized. The analytical method developed yields a pre-concentrated solution of plutonium from which (238)U and (241)Am have been removed, and which is suitable for the direct and simultaneous measurement of (239)Pu, (240)Pu, (241)Pu and (242)Pu by SF-ICP-MS.

  12. Imaging mass spectrometry statistical analysis.

    Science.gov (United States)

    Jones, Emrys A; Deininger, Sören-Oliver; Hogendoorn, Pancras C W; Deelder, André M; McDonnell, Liam A

    2012-08-30

    Imaging mass spectrometry is increasingly used to identify new candidate biomarkers. This clinical application of imaging mass spectrometry is highly multidisciplinary: expertise in mass spectrometry is necessary to acquire high quality data, histology is required to accurately label the origin of each pixel's mass spectrum, disease biology is necessary to understand the potential meaning of the imaging mass spectrometry results, and statistics to assess the confidence of any findings. Imaging mass spectrometry data analysis is further complicated because of the unique nature of the data (within the mass spectrometry field); several of the assumptions implicit in the analysis of LC-MS/profiling datasets are not applicable to imaging. The very large size of imaging datasets and the reporting of many data analysis routines, combined with inadequate training and accessible reviews, have exacerbated this problem. In this paper we provide an accessible review of the nature of imaging data and the different strategies by which the data may be analyzed. Particular attention is paid to the assumptions of the data analysis routines to ensure that the reader is apprised of their correct usage in imaging mass spectrometry research. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Ambient mass spectrometry imaging

    DEFF Research Database (Denmark)

    Janfelt, Christian; Nørgaard, Asger W

    2012-01-01

    , resulting in images of similar quality as DESI. EASI can thus be used in imaging experiments where the application of high voltage is impractical or undesirable. The present study is in its nature also a comparison of the characteristics of the two techniques, showing results also applicable for non-imaging...

  14. Imaging of fetal chest masses

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Richard A. [Lucile Packard Children' s Hospital, Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2012-01-15

    Prenatal imaging with high-resolution US and rapid acquisition MRI plays a key role in the accurate diagnosis of congenital chest masses. Imaging has enhanced our understanding of the natural history of fetal lung masses, allowing for accurate prediction of outcome, parental counseling, and planning of pregnancy and newborn management. This paper will focus on congenital bronchopulmonary malformations, which account for the vast majority of primary lung masses in the fetus. In addition, anomalies that mimic masses and less common causes of lung masses will be discussed. (orig.)

  15. Imaging in cardiac mass lesions

    International Nuclear Information System (INIS)

    Mundinger, A.; Gruber, H.P.; Dinkel, E.; Geibel, A.; Beck, A.; Wimmer, B.; Schlosser, V.

    1992-01-01

    In 26 patients with cardiac mass lesions confirmed by surgery, diagnostic imaging was performed preoperatively by means of two-dimensional echocardiography (26 patients), angiography (12 patients), correlative computed tomography (CT, 8 patients), and magnetic resonance imaging (MRI, 3 patients). Two-dimensional echocardiography correctly identified the cardiac masses in all patients. Angiography missed two of 12 cardiac masses; CT missed one of eight. MRI identified three of three cardiac masses. Although the sensitivity of two-dimensional echocardiography was high (100%), all methods lacked specificity. None of the methods allowed differentiation between myxoma (n=13) and thrombus (n=7). Malignancy of the lesions was successfully predicted by noninvasive imaging methods in all six patients. However, CT and MRI provided additional information concerning cardiac mural infiltration, pericardial involvement, and extracardiac tumor extension, and should be integrated within a preoperative imaging strategy. Thus two-dimensional echocardiography is the method of choice for primary assessment of patients with suspected cardiac masses. Further preoperative imaging by CT or MRI can be limited to patients with malignancies suspected on the grounds of pericardial effusion or other clinical results. (author)

  16. US and MR imaging of pelvic masses

    International Nuclear Information System (INIS)

    Angtuaco, T.L.; Boyd, C.M.; Mattison, D.R.; Williamson, M.R.; Sanders, M.M.; Bard, D.S.

    1987-01-01

    US and MR imaging were compared in benign and malignant pelvic masses to determine where MR imaging may replace US. With regard to benign masses, MR imaging showed a significant advantage only in the imaging of teratomas. In malignancy, US was better than MR imaging in delineating internal architecture. MR imaging was superior in suggesting the origin and extent of masses, especially in large neoplasms. US remains a reliable tool in the initial evaluation of pelvic masses. When US studies are suboptimal, MR imaging should be performed as complementary study. MR imaging may replace US in the initial examination of large masses where US cannot depict the origin and extent

  17. Imaging Mass Spectrometry in Neuroscience

    Science.gov (United States)

    2013-01-01

    Imaging mass spectrometry is an emerging technique of great potential for investigating the chemical architecture in biological matrices. Although the potential for studying neurobiological systems is evident, the relevance of the technique for application in neuroscience is still in its infancy. In the present Review, a principal overview of the different approaches, including matrix assisted laser desorption ionization and secondary ion mass spectrometry, is provided with particular focus on their strengths and limitations for studying different neurochemical species in situ and in vitro. The potential of the various approaches is discussed based on both fundamental and biomedical neuroscience research. This Review aims to serve as a general guide to familiarize the neuroscience community and other biomedical researchers with the technique, highlighting its great potential and suitability for comprehensive and specific chemical imaging. PMID:23530951

  18. Symplectic Tracking of Multi-Isotopic Heavy-Ion Beams in SixTrack

    CERN Document Server

    Hermes, Pascal; De Maria, Riccardo

    2016-01-01

    The software SixTrack provides symplectic proton tracking over a large number of turns. The code is used for the tracking of beam halo particles and the simulation of their interaction with the collimators to study the efficiency of the LHC collimation system. Tracking simulations for heavy-ion beams require taking into account the mass to charge ratio of each particle because heavy ions can be subject to fragmentation at their passage through the collimators. In this paper we present the derivation of a Hamiltonian for multi-isotopic heavy-ion beams and symplectic tracking maps derived from it. The resulting tracking maps were implemented in the tracking software SixTrack. With this modification, SixTrack can be used to natively track heavy-ion beams of multiple isotopes through a magnetic accelerator lattice.

  19. Cluster secondary ion mass spectrometry microscope mode mass spectrometry imaging.

    Science.gov (United States)

    Kiss, András; Smith, Donald F; Jungmann, Julia H; Heeren, Ron M A

    2013-12-30

    Microscope mode imaging for secondary ion mass spectrometry is a technique with the promise of simultaneous high spatial resolution and high-speed imaging of biomolecules from complex surfaces. Technological developments such as new position-sensitive detectors, in combination with polyatomic primary ion sources, are required to exploit the full potential of microscope mode mass spectrometry imaging, i.e. to efficiently push the limits of ultra-high spatial resolution, sample throughput and sensitivity. In this work, a C60 primary source was combined with a commercial mass microscope for microscope mode secondary ion mass spectrometry imaging. The detector setup is a pixelated detector from the Medipix/Timepix family with high-voltage post-acceleration capabilities. The system's mass spectral and imaging performance is tested with various benchmark samples and thin tissue sections. The high secondary ion yield (with respect to 'traditional' monatomic primary ion sources) of the C60 primary ion source and the increased sensitivity of the high voltage detector setup improve microscope mode secondary ion mass spectrometry imaging. The analysis time and the signal-to-noise ratio are improved compared with other microscope mode imaging systems, all at high spatial resolution. We have demonstrated the unique capabilities of a C60 ion microscope with a Timepix detector for high spatial resolution microscope mode secondary ion mass spectrometry imaging. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Reflections on imaging diagnosis of sella masses

    International Nuclear Information System (INIS)

    Hernandez Yero, Jose Arturo; Jorge Gonzalez, Raquel

    2005-01-01

    Some reflections were made on imaging diagnosis of sella masses, specifying some characteristics of the main sella masses and their appearance in magnetic resonance imaging. The purpose was to call the attention on this important issue on the basis that modern imaging advances offer very useful distinctive elements in the diagnosis of a group of masses located in the sella turcica region. The paper underlined details of signal intensity in pituitary adenomas, craniopharyngiomas, Rathkes pouch cysts, hypophyseal hyperplasia and the so-called empty sella syndrome, among other causes of anatomical changes in sella region. It was concluded that magnetic resonance imaging would be the ideal method for a better diagnosis of sella masses, but if this technique was not available, then contrast-enhanced tomography would be useful in under 2 mm views. The importance of a multidisciplinary team of clinicians, endocrinologists, imaging specialists, neurosurgeons and anatomy pathologists to reach more accurate diagnosis and better therapeutic results was stressed

  1. MR imaging of soft-tissue masses

    International Nuclear Information System (INIS)

    Fujimoto, H.; Murakami, K.; Ichikawa, T.; Matsubara, T.; Tsumurai, Y.; Masuda, S.; Terauchi, M.; Ozawa, K.; Arimizu, N.

    1990-01-01

    This paper evaluates the ability of T2*-weighted gradient-field-echo (T2*FE) MR imaging to image soft-tissue masses. The series included 26 cases, including 17 benign tumors, four malignant tumors, and five others. Images were obtained on a 0.5-T magnet with T2*FE imaging (300/22 [repetition time msec/echo time msec], 20 degree). Results were compared with those of T1-weighted spin-echo (SE) images (500/20--40) and T2-weighted SE (T2SE) images (2,000/80). T2*FE images were similar to T2SE images with respect to the signal intensity and internal architecture of the masses in many cases. In some instances, they were superior to T2SE images in depicting special features such as a hemosiderin deposit or in delineating the masses and adjacent fat tissues. Shorter (about one-third or two-thirds) scanning time was required to obtain T2*FE images than to obtain T2SE images

  2. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2012-01-01

    This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...... on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...

  3. FY09 PROGRESS: MULTI-ISOTOPE PROCESS (MIP) MONITOR

    International Nuclear Information System (INIS)

    Schwantes, Jon M.; Orton, Christopher R.; Fraga, Carlos G.; Christensen, Richard; Laspe, Amy R.; Ward, Rebecca M.

    2009-01-01

    Model and experimental estimates of the Multi-Isotope Process Monitor performance for determining burnup after dissolution and acid concentration during solvent extraction steps during reprocessing of spent nuclear fuel are presented. Modern industrial reprocessing techniques, including the PUREX and UREX+ family of separations technologies, are based on solvent extraction between organic and aqueous phases. In these bi-phase systems, product (actinide) and contaminant (fission and activation products) elements are preferentially driven (thermodynamically) to opposite phases, with small amounts of each remaining in the other phase. The distribution of each element, between the organic and aqueous phases, is determined by major process variables such as acid concentration, organic ligand concentration, reduction potential, and temperature. Hence, for consistent performance of the separation process, the distribution of each element between the organic and aqueous phases should be relatively constant. During 'normal' operations the pattern of elements distributing into the product and waste streams at each segment of the facility should be reproducible, resulting in a statistically significant signature of the nominal process conditions. Under 'abnormal' conditions, such as those expected under some protracted diversion scenarios, patterns of elements within the various streams would be expected to change measurably. The MIP monitoring approach utilizes changes in the concentrations of gamma-emitting elements as evidence of changes to the process chemistry. It exploits a suite of gamma emitting isotopes to track multiple chemical species and behaviors simultaneously, thus encompassing a large array of elements that are affected by chemical and physical changes. In-process surveillance by the MIP monitor is accomplished by coupling the gamma spectrometry of the streams with multivariate techniques, such as Principal Component Analysis (PCA). PCA is a chemometrics tool

  4. Mass-like extramedullary hematopoiesis: imaging features

    Energy Technology Data Exchange (ETDEWEB)

    Ginzel, Andrew W. [Synergy Radiology Associates, Houston, TX (United States); Kransdorf, Mark J.; Peterson, Jeffrey J.; Garner, Hillary W. [Mayo Clinic, Department of Radiology, Jacksonville, FL (United States); Murphey, Mark D. [American Institute for Radiologic Pathology, Silver Spring, MD (United States)

    2012-08-15

    To report the imaging appearances of mass-like extramedullary hematopoiesis (EMH), to identify those features that are sufficiently characteristic to allow a confident diagnosis, and to recognize the clinical conditions associated with EMH and the relative incidence of mass-like disease. We retrospectively identified 44 patients with EMH; 12 of which (27%) had focal mass-like lesions and formed the study group. The study group consisted of 6 male and 6 female subjects with a mean age of 58 years (range 13-80 years). All 12 patients underwent CT imaging and 3 of the 12 patients had undergone additional MR imaging. The imaging characteristics of the extramedullary hematopoiesis lesions in the study group were analyzed and recorded. The patient's clinical presentation, including any condition associated with extramedullary hematopoiesis, was also recorded. Ten of the 12 (83%) patients had one or more masses located along the axial skeleton. Of the 10 patients with axial masses, 9 (90%) had multiple masses and 7 (70%) demonstrated internal fat. Eight patients (80%) had paraspinal masses and 4 patients (40%) had presacral masses. Seven patients (70%) had splenomegaly. Eleven of the 12 patients had a clinical history available for review. A predisposing condition for extramedullary hematopoiesis was present in 10 patients and included various anemias (5 cases; 45%), myelofibrosis/myelodysplastic syndrome (4 cases; 36%), and marrow proliferative disorder (1 case; 9%). One patient had no known predisposing condition. Mass-like extramedullary hematopoiesis most commonly presents as multiple, fat-containing lesions localized to the axial skeleton. When these imaging features are identified, extramedullary hematopoiesis should be strongly considered, particularly when occurring in the setting of a predisposing medical condition. (orig.)

  5. [Imaging Mass Spectrometry in Histopathologic Analysis].

    Science.gov (United States)

    Yamazaki, Fumiyoshi; Seto, Mitsutoshi

    2015-04-01

    Matrix-assisted laser desorption/ionization (MALDI)-imaging mass spectrometry (IMS) enables visualization of the distribution of a range of biomolecules by integrating biochemical information from mass spectrometry with positional information from microscopy. IMS identifies a target molecule. In addition, IMS enables global analysis of biomolecules containing unknown molecules by detecting the ratio of the molecular weight to electric charge without any target, which makes it possible to identify novel molecules. IMS generates data on the distribution of lipids and small molecules in tissues, which is difficult to visualize with either conventional counter-staining or immunohistochemistry. In this review, we firstly introduce the principle of imaging mass spectrometry and recent advances in the sample preparation method. Secondly, we present findings regarding biological samples, especially pathological ones. Finally, we discuss the limitations and problems of the IMS technique and clinical application, such as in drug development.

  6. Cu-Zn-Pb multi isotopic characterization of a small watershed (Loire river basin, France)

    Science.gov (United States)

    Desaulty, A. M.; Millot, R.; Perret, S.; Bourrain, X.

    2015-12-01

    Combating metal pollution in surface water is a major environmental, public health and economic issue. Knowledge of the behavior of metals, such as copper (Cu), zinc (Zn) and lead (Pb) in sediments and dissolved load, is a key factor to improve the management of rivers. Recent advances in mass spectrometry related to the development of MC-ICPMS allow to analyze the isotopic composition of these elements, and previous studies show the effectiveness of isotopic analyses to determine the anthropogenic sources of pollution in environment. The goal of this study is to use the Cu-Zn-Pb multi-isotopic signature to track the pollutions in surface water, and to understand the complex processes causing the metals mobilization and transport in environment. More particularly we investigate the mechanisms of distribution between the dissolved load and particulate load, known to play an important role in the transport of metals through river systems. As case study, we chose a small watershed, poorly urbanized in the Loire river basin. Its spring is in a pristine area, while it is only impacted some kilometers further by the releases rich in metals coming from a hospital water treatment plant. First a sampling of these liquid effluents as well as dissolved load and sediment from upstream to downstream was realized and their concentrations and isotopic data were determined. Then to simulate a lot of potential natural and anthropogenic modifications of environmental conditions, we made sequential extraction protocol using various reagents on the sediments. Isotopic analyzes were performed also on the various extracting solutions. Isotopic ratios were measured using a Neptune MC-ICPMS at the BRGM, after a protocol of purification for Zn and Cu. The results showed that, these isotopic systematics reveal important informations about the mechanists of mobilization and transport of metals through river systems. However experiments performed under laboratory conditions will be necessary

  7. Quantitative mass imaging of single biological macromolecules.

    Science.gov (United States)

    Young, Gavin; Hundt, Nikolas; Cole, Daniel; Fineberg, Adam; Andrecka, Joanna; Tyler, Andrew; Olerinyova, Anna; Ansari, Ayla; Marklund, Erik G; Collier, Miranda P; Chandler, Shane A; Tkachenko, Olga; Allen, Joel; Crispin, Max; Billington, Neil; Takagi, Yasuharu; Sellers, James R; Eichmann, Cédric; Selenko, Philipp; Frey, Lukas; Riek, Roland; Galpin, Martin R; Struwe, Weston B; Benesch, Justin L P; Kukura, Philipp

    2018-04-27

    The cellular processes underpinning life are orchestrated by proteins and their interactions. The associated structural and dynamic heterogeneity, despite being key to function, poses a fundamental challenge to existing analytical and structural methodologies. We used interferometric scattering microscopy to quantify the mass of single biomolecules in solution with 2% sequence mass accuracy, up to 19-kilodalton resolution, and 1-kilodalton precision. We resolved oligomeric distributions at high dynamic range, detected small-molecule binding, and mass-imaged proteins with associated lipids and sugars. These capabilities enabled us to characterize the molecular dynamics of processes as diverse as glycoprotein cross-linking, amyloidogenic protein aggregation, and actin polymerization. Interferometric scattering mass spectrometry allows spatiotemporally resolved measurement of a broad range of biomolecular interactions, one molecule at a time. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  8. Identification of the geographical place of origin of an unidentified individual by multi-isotope analysis

    NARCIS (Netherlands)

    Font Morales, L.; van der Peijl, G.J.Q.; van Leeuwen, C.; van Wetten, I.A.; Davies, G.R.

    2015-01-01

    A multi-isotope investigation (Sr and Pb isotopes and δ18O, δ13C and δ15N) was applied to bone and teeth from an unidentified male found drowned in the"IJ" Ruyterkade in Amsterdam, The Netherlands in March of 1999. The individual remained unidentified until mid 2013, after the isotope study was

  9. Compressed sensing in imaging mass spectrometry

    International Nuclear Information System (INIS)

    Bartels, Andreas; Dülk, Patrick; Trede, Dennis; Alexandrov, Theodore; Maaß, Peter

    2013-01-01

    Imaging mass spectrometry (IMS) is a technique of analytical chemistry for spatially resolved, label-free and multipurpose analysis of biological samples that is able to detect the spatial distribution of hundreds of molecules in one experiment. The hyperspectral IMS data is typically generated by a mass spectrometer analyzing the surface of the sample. In this paper, we propose a compressed sensing approach to IMS which potentially allows for faster data acquisition by collecting only a part of the pixels in the hyperspectral image and reconstructing the full image from this data. We present an integrative approach to perform both peak-picking spectra and denoising m/z-images simultaneously, whereas the state of the art data analysis methods solve these problems separately. We provide a proof of the robustness of the recovery of both the spectra and individual channels of the hyperspectral image and propose an algorithm to solve our optimization problem which is based on proximal mappings. The paper concludes with the numerical reconstruction results for an IMS dataset of a rat brain coronal section. (paper)

  10. Correcting mass shifts: A lock mass-free recalibration procedure for mass spectrometry imaging data

    Czech Academy of Sciences Publication Activity Database

    Kulkarni, P.; Kaftan, F.; Kynast, P.; Svatoš, Aleš; Böcker, S.

    2015-01-01

    Roč. 407, č. 25 (2015), s. 7603-7613 ISSN 1618-2642 Institutional support: RVO:61388963 Keywords : mass spectrometry imaging * recalibration * mass shift correction * data processing Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 3.125, year: 2015

  11. Mass spectrometry imaging: Towards a lipid microscope?

    Science.gov (United States)

    Touboul, David; Brunelle, Alain; Laprévote, Olivier

    2011-01-01

    Biological imaging techniques are the most efficient way to locally measure the variation of different parameters on tissue sections. These analyses are gaining increasing interest since 20 years and allow observing extremely complex biological phenomena at lower and lower time and resolution scale. Nevertheless, most of them only target very few compounds of interest, which are chosen a priori, due to their low resolution power and sensitivity. New chemical imaging technique has to be introduced in order to overcome these limitations, leading to more informative and sensitive analyses for biologists and physicians. Two major mass spectrometry methods can be efficiently used to generate the distribution of biological compounds over a tissue section. Matrix-Assisted Laser Desorption/Ionisation-Mass Spectrometry (MALDI-MS) needs the co-crystallization of the sample with a matrix before to be irradiated by a laser, whereas the analyte is directly desorbed by a primary ion bombardment for Secondary Ion Mass Spectrometry (SIMS) experiments. In both cases, energy used for desorption/ionization is locally deposited -some tens of microns for the laser and some hundreds of nanometers for the ion beam- meaning that small areas over the surface sample can be separately analyzed. Step by step analysis allows spectrum acquisitions over the tissue sections and the data are treated by modern informatics software in order to create ion density maps, i.e., the intensity plot of one specific ion versus the (x,y) position. Main advantages of SIMS and MALDI compared to other chemical imaging techniques lie in the simultaneous acquisition of a large number of biological compounds in mixture with an excellent sensitivity obtained by Time-of-Flight (ToF) mass analyzer. Moreover, data treatment is done a posteriori, due to the fact that no compound is selectively marked, and let us access to the localization of different lipid classes in only one complete acquisition. Copyright © 2010

  12. Mass Spectrometry Imaging under Ambient Conditions

    Science.gov (United States)

    Wu, Chunping; Dill, Allison L.; Eberlin, Livia S.; Cooks, R. Graham; Ifa, Demian R.

    2012-01-01

    Mass spectrometry imaging (MSI) has emerged as an important tool in the last decade and it is beginning to show potential to provide new information in many fields owing to its unique ability to acquire molecularly specific images and to provide multiplexed information, without the need for labeling or staining. In MSI, the chemical identity of molecules present on a surface is investigated as a function of spatial distribution. In addition to now standard methods involving MSI in vacuum, recently developed ambient ionization techniques allow MSI to be performed under atmospheric pressure on untreated samples outside the mass spectrometer. Here we review recent developments and applications of MSI emphasizing the ambient ionization techniques of desorption electrospray ionization (DESI), laser ablation electrospray ionization (LAESI), probe electrospray ionization (PESI), desorption atmospheric pressure photoionization (DAPPI), femtosecond laser desorption ionization (fs-LDI), laser electrospray mass spectrometry (LEMS), infrared laser ablation metastable-induced chemical ionization (IR-LAMICI), liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS), nanospray desorption electrospray ionization (nano-DESI), and plasma sources such as the low temperature plasma (LTP) probe and laser ablation coupled to flowing atmospheric-pressure afterglow (LA-FAPA). Included are discussions of some of the features of ambient MSI including the ability to implement chemical reactions with the goal of providing high abundance ions characteristic of specific compounds of interest and the use of tandem mass spectrometry to either map the distribution of targeted molecules with high specificity or to provide additional MS information in the structural identification of compounds. We also describe the role of bioinformatics in acquiring and interpreting the chemical and spatial information obtained through MSI, especially in biological applications for tissue

  13. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  14. Pb-Zn-Cd-Hg multi isotopic characterization of the Loire River Basin, France

    Science.gov (United States)

    Millot, R.; Widory, D.; Innocent, C.; Guerrot, C.; Bourrain, X.; Johnson, T. M.

    2012-12-01

    metal pollutants. The main objective of this study is to characterize the sources and the behavior of these heavy metals in the aquatic environment, and their spatial distribution using a multi-isotope approach. Each of these isotope systematics on their own reveals important information about their geogenic or anthropogenic origin but, considered together, provide a more integrated understanding of the budgets of these pollutants within the Loire River Basin.

  15. Lipid imaging by mass spectrometry - a review.

    Science.gov (United States)

    Gode, David; Volmer, Dietrich A

    2013-03-07

    Mass spectrometry imaging (MSI) has proven to be extremely useful for applications such as the spatial analysis of peptides and proteins in biological tissue, the performance assessment of drugs in vivo or the measurement of protein or metabolite expression as tissue classifiers or biomarkers from disease versus control tissue comparisons. The most popular MSI technique is MALDI mass spectrometry. First invented by Richard Caprioli in the mid-1990s, it is the highest performing MSI technique in terms of spatial resolution, sensitivity for intact biomolecules and application range today. The unique ability to identify and spatially resolve numerous compounds simultaneously, based on m/z values has inter alia been applied to untargeted and targeted chemical mapping of biological compartments, revealing changes of physiological states, disease pathologies and metabolic faith and distribution of xenobiotics. Many MSI applications focus on lipid species because of the lipids' diverse roles as structural components of cell membranes, their function in the surfactant cycle, and their involvement as second messengers in signalling cascades of tissues and cells. This article gives a comprehensive overview of lipid imaging techniques and applications using established MALDI and SIMS methods but also other promising MSI techniques such as DESI.

  16. imzML: Imaging Mass Spectrometry Markup Language: A common data format for mass spectrometry imaging.

    Science.gov (United States)

    Römpp, Andreas; Schramm, Thorsten; Hester, Alfons; Klinkert, Ivo; Both, Jean-Pierre; Heeren, Ron M A; Stöckli, Markus; Spengler, Bernhard

    2011-01-01

    Imaging mass spectrometry is the method of scanning a sample of interest and generating an "image" of the intensity distribution of a specific analyte. The data sets consist of a large number of mass spectra which are usually acquired with identical settings. Existing data formats are not sufficient to describe an MS imaging experiment completely. The data format imzML was developed to allow the flexible and efficient exchange of MS imaging data between different instruments and data analysis software.For this purpose, the MS imaging data is divided in two separate files. The mass spectral data is stored in a binary file to ensure efficient storage. All metadata (e.g., instrumental parameters, sample details) are stored in an XML file which is based on the standard data format mzML developed by HUPO-PSI. The original mzML controlled vocabulary was extended to include specific parameters of imaging mass spectrometry (such as x/y position and spatial resolution). The two files (XML and binary) are connected by offset values in the XML file and are unambiguously linked by a universally unique identifier. The resulting datasets are comparable in size to the raw data and the separate metadata file allows flexible handling of large datasets.Several imaging MS software tools already support imzML. This allows choosing from a (growing) number of processing tools. One is no longer limited to proprietary software, but is able to use the processing software which is best suited for a specific question or application. On the other hand, measurements from different instruments can be compared within one software application using identical settings for data processing. All necessary information for evaluating and implementing imzML can be found at http://www.imzML.org .

  17. Preparation of a multi-isotope plutonium AMS standard and preliminary results of a first inter-lab comparison

    Energy Technology Data Exchange (ETDEWEB)

    Dittmann, B.-A.; Dunai, T.J. [Institute of Geology and Mineralogy, University of Cologne, Greinstr. 4-6, 50939 Cologne (Germany); Dewald, A.; Heinze, S.; Feuerstein, C. [Institute of Nuclear Physics, University of Cologne, Zülpicher Str. 77, 50937 Cologne (Germany); Strub, E. [Division of Nuclear Chemistry, University of Cologne, Zülpicher Str. 45, 50674 Cologne (Germany); Fifield, L.K.; Froehlich, M.B.; Tims, S.G.; Wallner, A. [Department of Nuclear Physics, Research School of Physics & Engineering, Australian National University, Canberra ACT 2601 (Australia); Christl, M. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland)

    2015-10-15

    The motivation of this work is to establish a new multi-isotope plutonium standard for isotopic ratio measurements with accelerator mass spectrometry (AMS), since stocks of existing solutions are declining. To this end, certified reference materials (CRMs) of each of the individual isotopes {sup 239}Pu, {sup 240}Pu, {sup 242}Pu and {sup 244}Pu were obtained from JRC IRMM (Joint Research Center Institute for Reference Materials and Measurements). These certified reference materials (IRMM-081a, IRMM-083, IRMM-043 and IRMM-042a) were diluted with nitric acid and mixed to obtain a stock standard solution with an isotopic ratio of approximately 1.0:1.0:1.0:0.1 ({sup 239}Pu:{sup 240}Pu:{sup 242}Pu:{sup 244}Pu). From this stock solution, samples were prepared for measurement of the plutonium isotopic composition by AMS. These samples have been measured in a round-robin exercise between the AMS facilities at CologneAMS, at the ANU Canberra and ETH Zurich to verify the isotopic ratio and to demonstrate the reproducibility of the measurements. The results show good agreement both between the different AMS measurements and with the gravimetrically determined nominal ratios.

  18. Are T2-weighted images necessary in renal mass characterization?

    International Nuclear Information System (INIS)

    Dann, Phoebe; Thakur, Ravi; Chin, Deanne; Krinsky, Glenn; Israel, Gary M.

    2006-01-01

    Objective: To determine what role T2-weighted images play in characterizing renal masses. Methods: Forty-four pathologically proven renal masses (34 renal cell carcinomas, 8 oncocytomas, 1 metanephric adenoma, 1 angiomyolipoma without macroscopic fat) and 38 simple renal cysts were evaluated with T1- and T2-weighted images at 1.5 T. Two independent and blinded readers initially characterized all masses using only the T1-weighed images (in- and opposed-phase chemical shift, unenhanced frequency-selective fat-suppressed, gadolinium-enhanced frequency-selective fat-suppressed and subtraction images) and placed each mass into one of three categories: nonsurgical, in need of follow-up, or surgical. The masses were then re-evaluated with the addition of the T2-weighted images. It was determined if the T2-weighted images changed the initial classification. Results: Forty-three of the 44 (98%) pathologically proven renal masses were characterized as a surgical mass using only the T1-weighted images. The remaining renal mass (a renal cell carcinoma) was characterized as a mass in which follow-up exams would be suggested. Thirty-eight of 38 (100%) simple renal cysts were correctly characterized using only the T1-weighted images. The T2-weighted images did not change the initial interpretation of the T1-weighted images in any of the cases. Conclusion: The results of this study suggest that T2-weighted images are not necessary in the evaluation of all renal masses and are specifically not necessary in the differentiation of solid and cystic renal neoplasms from simple renal cysts

  19. Imaging mass spectrometry in drug development and toxicology.

    Science.gov (United States)

    Karlsson, Oskar; Hanrieder, Jörg

    2017-06-01

    During the last decades, imaging mass spectrometry has gained significant relevance in biomedical research. Recent advances in imaging mass spectrometry have paved the way for in situ studies on drug development, metabolism and toxicology. In contrast to whole-body autoradiography that images the localization of radiolabeled compounds, imaging mass spectrometry provides the possibility to simultaneously determine the discrete tissue distribution of the parent compound and its metabolites. In addition, imaging mass spectrometry features high molecular specificity and allows comprehensive, multiplexed detection and localization of hundreds of proteins, peptides and lipids directly in tissues. Toxicologists traditionally screen for adverse findings by histopathological examination. However, studies of the molecular and cellular processes underpinning toxicological and pathologic findings induced by candidate drugs or toxins are important to reach a mechanistic understanding and an effective risk assessment strategy. One of IMS strengths is the ability to directly overlay the molecular information from the mass spectrometric analysis with the tissue section and allow correlative comparisons of molecular and histologic information. Imaging mass spectrometry could therefore be a powerful tool for omics profiling of pharmacological/toxicological effects of drug candidates and toxicants in discrete tissue regions. The aim of the present review is to provide an overview of imaging mass spectrometry, with particular focus on MALDI imaging mass spectrometry, and its use in drug development and toxicology in general.

  20. Absorption Mode FT-ICR Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O' Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  1. Surface analysis by imaging mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Vidová, Veronika; Volný, Michael; Lemr, Karel; Havlíček, Vladimír

    2009-01-01

    Roč. 74, 7-8 (2009), s. 1101-1116 ISSN 0010-0765 Institutional research plan: CEZ:AV0Z50200510 Keywords : secondary ion mass spectrometry * matrix assisted laser desorption ionization * mass spectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.856, year: 2009

  2. Multimodality imaging of placental masses: a pictorial review.

    Science.gov (United States)

    Jha, Priyanka; Paroder, Viktoriya; Mar, Winnie; Horowtiz, Jeanne M; Poder, Liina

    2016-12-01

    Placental masses are uncommonly identified at the time of obstetric ultrasound evaluation. Understanding the pathologies presenting as placental masses is key for providing a differential diagnosis and guiding subsequent management, which may include additional imaging with magnetic resonance (MR) imaging. Potential benign entities include chorioangiomas and teratomas. Larger chorioangiomas can cause fetal cardiovascular issues from volume overload. Placental mesenchymal dysplasia has an association with fetal anomalies and detailed fetal evaluation should be performed when it is suspected. Identifying other cystic masses such as partial and complete moles is crucial to prevent erroneous pregnancy termination. This review addresses normal imaging appearance of the placenta on ultrasound and MR imaging and describes various trophoblastic and nontrophoblastic placental masses. Potential placental mass mimics including uterine contractions and thrombo-hematomas are also presented.

  3. Real-time software for multi-isotopic source term estimation

    International Nuclear Information System (INIS)

    Goloubenkov, A.; Borodin, R.; Sohier, A.

    1996-01-01

    Consideration is given to development of software for one of crucial components of the RODOS - assessment of the source rate (SR) from indirect measurements. Four components of the software are described in the paper. First component is a GRID system, which allow to prepare stochastic meteorological and radioactivity fields using measured data. Second part is a model of atmospheric transport which can be adapted for emulation of practically any gamma dose/spectrum detectors. The third one is a method which allows space-time and quantitative discrepancies in measured and modelled data to be taken into account simultaneously. It bases on the preference scheme selected by an expert. Last component is a special optimization method for calculation of multi-isotopic SR and its uncertainties. Results of a validation of the software using tracer experiments data and Chernobyl source estimation for main dose-forming isotopes are enclosed in the paper

  4. An Image Morphing Technique Based on Optimal Mass Preserving Mapping

    Science.gov (United States)

    Zhu, Lei; Yang, Yan; Haker, Steven; Tannenbaum, Allen

    2013-01-01

    Image morphing, or image interpolation in the time domain, deals with the metamorphosis of one image into another. In this paper, a new class of image morphing algorithms is proposed based on the theory of optimal mass transport. The L2 mass moving energy functional is modified by adding an intensity penalizing term, in order to reduce the undesired double exposure effect. It is an intensity-based approach and, thus, is parameter free. The optimal warping function is computed using an iterative gradient descent approach. This proposed morphing method is also extended to doubly connected domains using a harmonic parameterization technique, along with finite-element methods. PMID:17547128

  5. Mass Spectrometry Imaging, an Emerging Technology in Neuropsychopharmacology

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Svenningsson, Per; Andrén, Per E

    2014-01-01

    Mass spectrometry imaging is a powerful tool for directly determining the distribution of proteins, peptides, lipids, neurotransmitters, metabolites and drugs in neural tissue sections in situ. Molecule-specific imaging can be achieved using various ionization techniques that are suited to different applications but which all yield data with high mass accuracies and spatial resolutions. The ability to simultaneously obtain images showing the distributions of chemical species ranging from metal ions to macromolecules makes it possible to explore the chemical organization of a sample and to correlate the results obtained with specific anatomical features. The imaging of biomolecules has provided new insights into multiple neurological diseases, including Parkinson's and Alzheimer's disease. Mass spectrometry imaging can also be used in conjunction with other imaging techniques in order to identify correlations between changes in the distribution of important chemical species and other changes in the properties of the tissue. Here we review the applications of mass spectrometry imaging in neuroscience research and discuss its potential. The results presented demonstrate that mass spectrometry imaging is a useful experimental method with diverse applications in neuroscience. PMID:23966069

  6. Mass spectrometry imaging, an emerging technology in neuropsychopharmacology.

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Svenningsson, Per; Andrén, Per E

    2014-01-01

    Mass spectrometry imaging is a powerful tool for directly determining the distribution of proteins, peptides, lipids, neurotransmitters, metabolites and drugs in neural tissue sections in situ. Molecule-specific imaging can be achieved using various ionization techniques that are suited to different applications but which all yield data with high mass accuracies and spatial resolutions. The ability to simultaneously obtain images showing the distributions of chemical species ranging from metal ions to macromolecules makes it possible to explore the chemical organization of a sample and to correlate the results obtained with specific anatomical features. The imaging of biomolecules has provided new insights into multiple neurological diseases, including Parkinson's and Alzheimer's disease. Mass spectrometry imaging can also be used in conjunction with other imaging techniques in order to identify correlations between changes in the distribution of important chemical species and other changes in the properties of the tissue. Here we review the applications of mass spectrometry imaging in neuroscience research and discuss its potential. The results presented demonstrate that mass spectrometry imaging is a useful experimental method with diverse applications in neuroscience.

  7. Biomarker discovery in high grade sarcomas by mass spectrometry imaging

    OpenAIRE

    Lou, S.

    2017-01-01

    This thesis demonstrates a detailed biomarker discovery Mass Spectrometry Imaging workflow for histologically heterogeneous high grade sarcomas. Panels of protein and metabolite signatures were discovered either distinguishing different histological subtypes or stratifying high risk patients with poor survival.

  8. Automated, parallel mass spectrometry imaging and structural identification of lipids

    DEFF Research Database (Denmark)

    Ellis, Shane R.; Paine, Martin R.L.; Eijkel, Gert B.

    2018-01-01

    We report a method that enables automated data-dependent acquisition of lipid tandem mass spectrometry data in parallel with a high-resolution mass spectrometry imaging experiment. The method does not increase the total image acquisition time and is combined with automatic structural assignments....... This lipidome-per-pixel approach automatically identified and validated 104 unique molecular lipids and their spatial locations from rat cerebellar tissue....

  9. Reconstructing building mass models from UAV images

    KAUST Repository

    Li, Minglei; Nan, Liangliang; Smith, Neil; Wonka, Peter

    2015-01-01

    We present an automatic reconstruction pipeline for large scale urban scenes from aerial images captured by a camera mounted on an unmanned aerial vehicle. Using state-of-the-art Structure from Motion and Multi-View Stereo algorithms, we first

  10. Imaging Teachers: In Fact and in the Mass Media.

    Science.gov (United States)

    Reyes, Xae Alicia; Rios, Diana I.

    2003-01-01

    The impact of mass media on public images of teachers and students is considered in a dialogue between two educational and mass media researchers. Stereotypes in films, such as teacher-savior and student-failure, and abundant reports about Latino dropout rates and low academic achievement impact teachers and the public, who accept negative images…

  11. Molecular mass spectrometry imaging in biomedical and life science research

    Czech Academy of Sciences Publication Activity Database

    Pól, Jaroslav; Strohalm, Martin; Havlíček, Vladimír; Volný, Michael

    2010-01-01

    Roč. 134, č. 5 (2010), s. 423-443 ISSN 0948-6143 R&D Projects: GA MŠk LC545; GA ČR GPP206/10/P018 Institutional research plan: CEZ:AV0Z50200510 Keywords : Mass spectrometry * Chemical imaging * Molecular imaging Subject RIV: EE - Microbiology, Virology Impact factor: 4.727, year: 2010

  12. Reconstructing building mass models from UAV images

    KAUST Repository

    Li, Minglei

    2015-07-26

    We present an automatic reconstruction pipeline for large scale urban scenes from aerial images captured by a camera mounted on an unmanned aerial vehicle. Using state-of-the-art Structure from Motion and Multi-View Stereo algorithms, we first generate a dense point cloud from the aerial images. Based on the statistical analysis of the footprint grid of the buildings, the point cloud is classified into different categories (i.e., buildings, ground, trees, and others). Roof structures are extracted for each individual building using Markov random field optimization. Then, a contour refinement algorithm based on pivot point detection is utilized to refine the contour of patches. Finally, polygonal mesh models are extracted from the refined contours. Experiments on various scenes as well as comparisons with state-of-the-art reconstruction methods demonstrate the effectiveness and robustness of the proposed method.

  13. Myofiber metabolic type determination by mass spectrometry imaging

    OpenAIRE

    Théron, Laetitia; Vénien, Annie; Pujos-Guillot, Estelle; Astruc, Thierry; Chambon, Christophe

    2017-01-01

    In muscle imaging, myofiber type determination is of great importance to better understand biological mechanisms related to skeletal muscle changes associated with pathologies. However, reference methods (histo-enzymology and immunohistochemistry) require serial-cross sections, and several days from the sampling to the results of image analysis. In this work, a strategy based on MALDI-Mass Spectrometry Imaging was developed as an alternative to the classical methods for myofiber metabolic typ...

  14. TEM Imaging of Mass-selected Polymer Molecules

    International Nuclear Information System (INIS)

    Nasibulin, Albert G.; Kauppinen, Esko I.; Thomson, Bruce A.; Fernandez de la Mora, J.

    2002-01-01

    Polyethylene glycol (PEG) molecules with masses below 1300 amu are electrosprayed (ES) from solution, mobility-selected at high resolution in a differential mobility analyzer (DMA), collected on a grid and imaged by transmission electron microscopy (ES-DMA-TEM). The DMA resolves individual n-mers, and selects only one out of the many present in the original sample. Ion identity is established from parallel mass spectra (ES-MS). The images reveal spherical particles 1.46 nm in diameter, in good agreement with the known ion mass and bulk density. The DMA-selection technique opens new paths for the study of very small particles

  15. Proteomic Mass Spectrometry Imaging for Skin Cancer Diagnosis.

    Science.gov (United States)

    Lazova, Rossitza; Seeley, Erin H

    2017-10-01

    Mass spectrometry imaging can be successfully used for skin cancer diagnosis, particularly for the diagnosis of challenging melanocytic lesions. This method analyzes proteins within benign and malignant melanocytic tumor cells and, based on their differences, which constitute a unique molecular signature of 5 to 20 proteins, can render a diagnosis of benign nevus versus malignant melanoma. Mass spectrometry imaging may assist in the differentiation between metastases and nevi as well as between proliferative nodules in nevi and melanoma arising in a nevus. In the difficult area of atypical Spitzoid neoplasms, mass spectrometry diagnosis can predict clinical outcome better than histopathology. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  17. Imaging of mass distribution in paper by electrography technique, (2)

    International Nuclear Information System (INIS)

    Tomimasu, Hiroshi; Luner, P.

    1991-01-01

    Four paper imaging techniques (β-radiography, electrography, light transmission, and soft x-radiography) were compared in terms of their process parameters and image characteristics (exposure time, spatial variation, contrast, spatial resolution, correlation with mass, and limitation in basis weight range) with the same newsprint sample and electron microscope film. As far as the imaging conditions chosen here are concerned, electrography gave a higher spatial resolution, shorter exposure time, and the wider basis weight range than β-radiography. Light transmission image could be obtained in a very short time, but gave the poorest spatial resolution and correlation with mass. Soft x-radiography gave the highest spatial resolution, but the poorest spatial variation and contrast. The proper imaging technique and conditions need to be selected depending on the specific paper property in question. (author)

  18. Gd-DTPA administered MR imaging of intracranial mass lesions

    International Nuclear Information System (INIS)

    Mihara, Futoshi; Hirakata, Ryosuke; Hasuo, Kanehiro; Yasumori, Kotaro; Yoshida, Kisaku; Kuroiwa, Toshiro; Masuda, Kouji; Fukui, Masashi

    1989-01-01

    Magnetic resonance (MR) images of 13 intracranial mass lesions taken with the intravenous administration of gadolinium-DTPA were evaluated in comparison with precontrast computed tomography (CT), postcontrast CT, and precontrast MR. In the MR images taken with Gd-DTPA, tumor delineation improved in eight of 13 cases (62%) in comparison with precontrast MR images, and in seven of 13 cases (54%) in comparison with the overall evaluation of precontrast CT, postcontrast CT, and precontrast MR images. Tumor demarcation was unchanged in the remaining cases; no deterioration was observed with Gd-DTPA administration. MR imaging with Gd-DTPA should be performed to better evaluate the extent of intracranial mass lesions and to provide additional information. (author)

  19. Salivary gland masses. Dynamic MR imaging and pathologic correlation

    International Nuclear Information System (INIS)

    Park, Jinho; Inoue, Shingo; Ishizuka, Yasuhito; Shindo, Hiroaki; Kawanishi, Masayuki; Kakizaki, Dai; Abe, Kimihiko; Ebihara, Yoshiro

    1997-01-01

    To evaluate the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI) for the diagnosis of salivary gland masses. We retrospectively examined 19 salivary gland masses that were pathologically diagnosed by surgical operation or biopsy. We obtained T1- and T2-weighted images on MRI, performed dynamic studies on each mass and examined the correlation between enhancement patterns and pathological findings. Four enhancement patterns were recognized on contrast-enhanced MRI: type 1 showed marked, homogeneous enhancement; type 2 slights, homogeneous enhancement; type 3 marginal enhancement; and type 4 poor enhancement of the mass. Most pleomorphic adenomas had a type 1 enhancement pattern, but two had a type 2 pattern. Pathologically, each mass enhancement pattern had different tumor cell and matrix components. Warthin's tumor generally showed the type 4 pattern. Primary malignant tumors of the salivary gland all showed the type 3 pattern, and pathological specimens showed many tumor cells along the marginal portion of the tumor. One inflammatory cyst and one Warthin's tumor also showed the type 3 pattern. Except for metastatic renal cell carcinoma, the enhancement patterns of late phase images and dynamic study images were the same. Dynamic MRI added little diagnostic information about salivary gland masses, but the contrast-enhanced MR features correlated well with the pathological findings. (author)

  20. Congenital frontonasal masses: developmental anatomy, malformations, and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hedlund, Gary [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States)

    2006-07-15

    The newborn, infant, or young child who presents with a midline frontonasal mass often poses a diagnostic challenge to the clinician. The most pressing issue is whether the mass extends intracranially. The development of the frontonasal region or anterior neuropore is complex. Aberrant embryogenesis leads to three main types of anomalies: nasal dermal sinus, anterior cephalocele, and nasal glioma. Understanding the developmental anatomy of the anterior neuropore and postnatal maturation will serve the radiologist well when it comes to imaging frontonasal masses. Pitfalls particularly common to CT imaging interpretation include the evolving ossification of the frontal, nasal and ethmoid bones in the first year of life, morphology and size of the foramen cecum, and the natural intumescence of the anterior nasal septum. Determination of the presence of a connection between the frontonasal mass and the anterior cranial fossae is crucial in the imaging assessment and clinical management. In the case of the nasal dermal sinus, failure to appreciate the intracranial components of the malformation can lead to fatal meningitis. MR imaging is the modality of choice for assessing the pediatric frontonasal region. Its advantages include multiplanar imaging, distinguishing the interface among cartilage, bone, brain and fluid, diffusion imaging to detect epidermoid tumors, and the capacity to evaluate the brain for associated cerebral anomalies. (orig.)

  1. Body image in the mass media

    Directory of Open Access Journals (Sweden)

    Claudia Iris Bazán

    2015-12-01

    Full Text Available The concern about weight that characterizes most modern women stemmed from the medical research that showed the relationship between obesity and diseases such as hypertension or cardiovascular disease. As shown by the American filmmaker Michael Moore in his documentary film “Sicko” in 2007, large US health companies financially rewarded those with a thinner body and sanctioned overweight people because they had higher risks of disease and thus generate losses to their companies. From there, the emphasis on weight control and low-calorie dieting -and its association with health- reached unexpected limits. Mass Media had and have a leading role on this growing concern about weight. This article analyzes the effects of media on the aesthetic / healthy ideal, which contribute to the construction of a woman captured by endless demands. These social requirements are associated with perfection, the predominance of the aesthetic, healthy body and eternal youth, which would guarantee success. What relationship have television, women’s magazines, Internet, advertising and even children’s toys with the expansion of “the culture of light”, the ideal body and healthy behavior are some of the questions that will be addressed in this Article. To contribute to a better understanding of this phenomenon, we will make a bibliographic and Media exploration. Finally, as a possible solution to the problem, a strategy of state intervention on the current market model for promoting good use of information and prevention of Eating Disorders and other diseases related to poor diet is proposed. 

  2. Image resolution influence on determination of resin injection rock mass

    Science.gov (United States)

    Wang, Weixing; Hakami, Eva

    2006-01-01

    In the context of nuclear waste repositories, an important approach to understanding brittle rock mass behavior to integrate new and powerful observational and numerical methods with multi-functional 3-D imaging and visualization techniques. Since 1994, Swedish Nuclear Fuel and Waste Management Company (SKB) have identified the need for a better understanding of radionuclide transport and retention processes in fractured rock. As a cooperation project between Sweden and China, we sampled a number of rock specimens for analyze rock fracture network by optical image technique. The samples are resin injected, in which way; opened fractures can be seen clearly by means of UV (Ultraviolet) light illumination. In the study period, we used different optical focuses to obtain the images from the same samples; we found that Image resolution influences on porosity determination of resin injected rock mass. This paper presents and discusses the six issues based on our research results: (1) Fracture porosity increases as camera focus distance decreases; (2) Porosity increases as illumination increases in resin injected fracture images; (3) To roughly estimate the porosity, the low resolution image can be used; (4) To collect more details of fracture information, the high resolution image is needed; (5) The resolution of image should be determined based on the aim of fracture analysis; (6) To acquire high resolution image, constructing a special illumination (standard) box maybe helpful to avoid light reflection and diffusion.

  3. Cross-sectional imaging in pediatric neck masses

    International Nuclear Information System (INIS)

    Koenigsberg, R.A.; Patel, M.; Horowitz, C.

    1990-01-01

    This paper reports on US, CT, and MR imaging that demonstrates unique roles in the evaluation of pediatric neck masses. The causes of these masses range from infections/abscesses to primary and secondary tumors. The purpose of this paper is to review pediatric neck masses and the current role of cross-sectional imaging. Seventy-one examinations of the neck by means of CT, US, and MR imaging on 62 patients aged 1-21 y were retrospectively reviewed. Diseases were categorized according to benign versus malignant causes. Benign: 9 abscesses/cellulitis, 5 thyroglossal duct cysts, 3 branchial cleft cysts, 2 parotid cysts, 2 benign enlarged lumphadenopathies, 2 cystic hydromas, 1 ranula, and 1 hematoma

  4. The Multi-Isotope Process (MIP) Monitor Project: FY13 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Meier, David E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coble, Jamie B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, David V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mcdonald, Luther W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Forrester, Joel B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schwantes, Jon M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Unlu, Kenan [Pennsylvania State Univ., University Park, PA (United States); Landsberger, Sheldon [Univ. of Texas, Austin, TX (United States); Bender, Sarah [Pennsylvania State Univ., University Park, PA (United States); Dayman, Kenneth J. [Univ. of Texas, Austin, TX (United States); Reilly, Dallas D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of “… (minimization of) the risks of nuclear proliferation and terrorism.” The MIP Monitor measures the distribution of the radioactive isotopes in product and waste streams of a nuclear reprocessing facility. These isotopes are monitored online by gamma spectrometry and compared, in near-real-time, to spectral patterns representing “normal” process conditions using multivariate analysis and pattern recognition algorithms. The combination of multivariate analysis and gamma spectroscopy allows us to detect small changes in the gamma spectrum, which may indicate changes in process conditions. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting for systems representing aqueous reprocessing facilities. However, pyroprocessing is emerging as an alternative to aqueous reprocessing techniques.

  5. Multi-Isotope Process (MIP) Monitor: A Near-Real-Time Monitor For Reprocessing Facilities

    International Nuclear Information System (INIS)

    Schwantes, Jon M.; Douglas, Matthew; Orton, Christopher R.; Fraga, Carlos G.; Christensen, Richard

    2008-01-01

    The threat of protracted diversion of Pu from commercial reprocessing operations is perhaps the greatest concern to national and international agencies tasked with safeguarding these facilities. While it is generally understood that a method for direct monitoring of process on-line and in near-real time (NRT) would be the best defense against protracted diversion scenarios, an effective method with these qualities has yet to be developed. Here, we attempt to bridge this gap by proposing an on-line NRT process monitoring method that should be sensitive to minor alterations in process conditions and compatible with small, easily deployable, detection systems. This Approach is known as the Multi-Isotope Process (MIP) Monitor and involves the determination and recognition of the contaminant pattern within a process stream for a suite of indicator (radioactive) elements present in the spent fuel as a function of process variables. Utilization of a suite of radio-elements, including ones with multiple oxidation states, decreases the likelihood that attempts to divert Pu by altering the ReDox environment within the process would go undetected. In addition, by identifying gamma-emitting indicator isotopes, this Approach might eliminate the need for bulky neutron detection systems, relying instead on small, portable, high-resolution gamma detectors easily deployable throughout the facility

  6. Imaging manifestations of neck masses in the immunocompromised host

    International Nuclear Information System (INIS)

    Taylor, N.; Scarsbrook, A.F.; Conlon, C.P.; Anslow, P.A.; Phillips, R.R.

    2007-01-01

    Human immunodeficiency virus (HIV) infection, haematological malignancy, and immunosuppression for transplantation and autoimmune disorders have led to a large increase in immunocompromised patients. Neck masses are relatively common in this patient group and include both opportunistic and severe manifestations of common infections, benign hyperplasia, and primary or secondary malignancies. Although biopsy may be necessary for definitive diagnosis, features on cross-sectional imaging may suggest a specific diagnosis or limit the differential diagnosis and facilitate optimal patient management. This article will review critical aspects of neck anatomy, illustrate the spectrum of imaging features, and discuss the interpretative pearls and pitfalls when evaluating neck masses in immunocompromised patients

  7. Vaginal Masses: Magnetic Resonance Imaging Features with Pathologic Correlation

    International Nuclear Information System (INIS)

    Elsayes, K.M.; Narra, V.R.; Dillman, J.R.; Velcheti, V.; Hameed, O.; Tongdee, R.; Menias, C.O.

    2007-01-01

    The detection of vaginal lesions has increased with the expanding use of cross-sectional imaging. Magnetic resonance imaging (MRI) - with its high-contrast resolution and multiplanar capabilities - is often useful for characterizing vaginal masses. Vaginal masses can be classified as congenital, inflammatory, cystic (benign), and neoplastic (benign or malignant) in etiology. Recognition of the typical MR imaging features of such lesions is important because it often determines the treatment approach and may obviate surgery. Finally, vaginal MR imaging can be used to evaluate post-treatment changes related to previous surgery and radiation therapy. In this article, we will review pertinent vaginal anatomy, vaginal and pelvic MRI technique, and the MRI features of a variety of vaginal lesions with pathological correlation

  8. Role of gadolinium in MR imaging of sinonasal masses

    International Nuclear Information System (INIS)

    Lanzieri, C.F.; Shah, M.; Smith, A.S.; Tarr, R.; Van Dyke, C.; Kaufman, B.; Krauss, D.; Lavertu, P.

    1990-01-01

    This paper determines whether additional clinically useful information can be obtained with the use of contrast-enhanced MR imaging, compared with nonenhanced MR imaging and enhanced CT, in the evaluation of patients with sinonasal masses. Twenty-one patients with CT evidence of a sinonasal mass were imaged at 1.5 T with T1 and T2 weighting and without and with gadolinium injection. The studies were interpreted independently and correlated with the surgical and pathologic findings. The contrast-enhanced MR images yielded additional clinically useful information in 13 of 21 cases. It was the only way to separate tumor from a mucocele in four of 13 cases. In two of 13 instances, it was the only modality that identified encephalocele as distinct from a tumor. In the remaining seven cases, more accurate delineation of the tumor margins was obtained

  9. Mass Spectrometry Imaging for the Classification of Tumor Tissue

    NARCIS (Netherlands)

    Mascini, N.E.

    2016-01-01

    Mass spectrometry imaging (MSI) can detect and identify many different molecules without the need for labeling. In addition, it can provide their spatial distributions as ‘molecular maps’. These features make MSI well suited for studying the molecular makeup of tumor tissue. Currently, there is an

  10. Silver nanostructures in laser desorption/ionization mass spectrometry and mass spectrometry imaging.

    Science.gov (United States)

    Sekuła, Justyna; Nizioł, Joanna; Rode, Wojciech; Ruman, Tomasz

    2015-09-21

    Silver nanoparticles have been successfully applied as a matrix replacement for the laser desorption/ionization time-of-flight mass spectrometry (LDI-ToF-MS). Nanoparticles, producing spectra with highly reduced chemical background in the low m/z region, are perfectly suited for low-molecular weight compound analysis and imaging. Silver nanoparticles (AgNPs) can efficiently absorb ultraviolet laser radiation, transfer energy to the analyte and promote analyte desorption, but also constitute a source of silver ions suitable for analyte cationisation. This review provides an overview of the literature on silver nanomaterials as non-conventional desorption and ionization promoters in LDI-MS and mass spectrometry imaging.

  11. Mass Spectrometry Imaging of Drugs of Abuse in Hair.

    Science.gov (United States)

    Flinders, Bryn; Cuypers, Eva; Porta, Tiffany; Varesio, Emmanuel; Hopfgartner, Gérard; Heeren, Ron M A

    2017-01-01

    Hair testing is a powerful tool routinely used for the detection of drugs of abuse. The analysis of hair is highly advantageous as it can provide prolonged drug detectability versus that in biological fluids and chronological information about drug intake based on the average growth of hair. However, current methodology requires large amounts of hair samples and involves complex time-consuming sample preparation followed by gas or liquid chromatography coupled with mass spectrometry. Mass spectrometry imaging is increasingly being used for the analysis of single hair samples, as it provides more accurate and visual chronological information in single hair samples.Here, two methods for the preparation of single hair samples for mass spectrometry imaging are presented.The first uses an in-house built cutting apparatus to prepare longitudinal sections, the second is a method for embedding and cryo-sectioning hair samples in order to prepare cross-sections all along the hair sample.

  12. Kinetic quantification of vertical solid matter transfers in soils by a multi-isotopic approach

    International Nuclear Information System (INIS)

    Jagercikova, Marianna

    2014-01-01

    Clay translocation is one of the major soil forming processes, however it is poorly quantified and modeled. We propose to quantify it together with bioturbation by combining different isotopic systems ( 137 Cs, 210 Pb (xs), meteoric 10 Be, 206/207 Pb, δ 13 C, 14 C) with numerical modeling based on a nonlinear diffusion-convection equation with depth dependent parameters. This novel method has been applied on Luvisol anthropo-sequences developed on loess, differing by their land use (cropping versus grassland or forest) and their agricultural practices (reduced tillage, no tillage and manure input). Our results show that as much as 91 ± 9 % and 80 ± 9 % of 137 Cs and 10 Be, respectively, are associated to the clay size fraction (0-2 μm) and can thus effectively trace vertical solid matter transfers in soils with pH > 5 and low organic carbon. Lead partitioning between different solid phases is more complex. Considering two spatial distributions of isotopes (macro-pores or soil matrix), we built up a multi-isotopic modelling approach that simulates the experimental data with the common set of transfer parameters and allowed us to quantify the relative contributions of vertical solid matter transfers to present-day 0-2 μm vertical distributions. Clay translocation is responsible for 9 to 66 % of the clay accumulations in the Bt-horizon. The diffusion coefficient also quantifies the rate of soil mixing by bioturbation. Modeling of the kinetics of solid matter transfer at multiple spatio-temporal scales should become a method of predilection in modern pedogenic and critical zone studies. (author) [fr

  13. Soluble salt sources in medieval porous limestone sculptures: A multi-isotope (N, O, S) approach

    Energy Technology Data Exchange (ETDEWEB)

    Kloppmann, W., E-mail: w.kloppmann@brgm.fr [BRGM, Direction des Laboratoires, Unité Isotopes, BP 6009, F-45060 Orléans cedex 2 (France); Rolland, O., E-mail: olivierrolland@wanadoo.fr [Montlouis-sur-Loire (France); Proust, E.; Montech, A.T. [BRGM, Direction des Laboratoires, Unité Isotopes, BP 6009, F-45060 Orléans cedex 2 (France)

    2014-02-01

    The sources and mechanisms of soluble salt uptake by porous limestone and the associated degradation patterns were investigated for the life-sized 15th century “entombment of Christ” sculpture group located in Pont-à-Mousson, France, using a multi-isotope approach on sulphates (δ{sup 34}S and δ{sup 18}O) and nitrates (δ{sup 15}N and δ{sup 18}O). The sculpture group, near the border of the Moselle River, is within the potential reach of capillary rise from the alluvial aquifer. Chemical analyses show a vertical zonation of soluble salts with a predominance of sulphates in the lower parts of the statues where crumbling and blistering prevail, and higher concentrations of nitrates and chloride in the high parts affected by powdering and efflorescence. Isotope fingerprints of sulphates suggest a triple origin: (1) the lower parts are dominated by capillary rise of dissolved sulphate from the Moselle water with characteristic Keuper evaporite signatures that progressively decreases with height; (2) in the higher parts affected by powdering the impact of atmospheric sulphur becomes detectable; and (3) locally, plaster reparations impact the neighbouring limestone through dissolution and re-precipitation of gypsum. Nitrogen and oxygen isotopes suggest an organic origin of nitrates in all samples. N isotope signatures are compatible with those measured in the alluvial aquifer of the Moselle River further downstream. This indicates contamination by sewage or organic fertilisers. Significant isotopic contrasts are observed between the different degradation features depending on the height and suggest historical changes of nitrate sources. - Highlights: • We use S, N and O isotopes to distinguish salt sources in limestone sculptures. • Vertical zonation of degradation is linked to capillary rise and air pollution. • Sulphate salts in lower parts are derived from river/groundwater. • Sulphate salts in higher parts show signature of air pollution. • Nitrates

  14. A study on assessment of bone mass from aluminum-equivalent image by digital imaging system

    International Nuclear Information System (INIS)

    Kim, Jin Soo; Kim, Jae Duck; Choi, Eui Hwan

    1997-01-01

    The purpose of this study was to evaluated the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxy apatite block and hydroxyapatite mass. The results of this study were as follows : 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated (r2=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference (P<0.05) between them. 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r2 =0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different (P<0.05).

  15. High mass accuracy and high mass resolving power FT-ICR secondary ion mass spectrometry for biological tissue imaging

    NARCIS (Netherlands)

    Smith, D.F.; Kiss, A.; Leach, F.E.; Robinson, E.W.; Paša-Tolić, L.; Heeren, R.M.A.

    2013-01-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically

  16. Mass spectrometry imaging enriches biomarker discovery approaches with candidate mapping.

    Science.gov (United States)

    Scott, Alison J; Jones, Jace W; Orschell, Christie M; MacVittie, Thomas J; Kane, Maureen A; Ernst, Robert K

    2014-01-01

    Integral to the characterization of radiation-induced tissue damage is the identification of unique biomarkers. Biomarker discovery is a challenging and complex endeavor requiring both sophisticated experimental design and accessible technology. The resources within the National Institute of Allergy and Infectious Diseases (NIAID)-sponsored Consortium, Medical Countermeasures Against Radiological Threats (MCART), allow for leveraging robust animal models with novel molecular imaging techniques. One such imaging technique, MALDI (matrix-assisted laser desorption ionization) mass spectrometry imaging (MSI), allows for the direct spatial visualization of lipids, proteins, small molecules, and drugs/drug metabolites-or biomarkers-in an unbiased manner. MALDI-MSI acquires mass spectra directly from an intact tissue slice in discrete locations across an x, y grid that are then rendered into a spatial distribution map composed of ion mass and intensity. The unique mass signals can be plotted to generate a spatial map of biomarkers that reflects pathology and molecular events. The crucial unanswered questions that can be addressed with MALDI-MSI include identification of biomarkers for radiation damage that reflect the response to radiation dose over time and the efficacy of therapeutic interventions. Techniques in MALDI-MSI also enable integration of biomarker identification among diverse animal models. Analysis of early, sublethally irradiated tissue injury samples from diverse mouse tissues (lung and ileum) shows membrane phospholipid signatures correlated with histological features of these unique tissues. This paper will discuss the application of MALDI-MSI for use in a larger biomarker discovery pipeline.

  17. Challenges and recent advances in mass spectrometric imaging of neurotransmitters

    Science.gov (United States)

    Gemperline, Erin; Chen, Bingming; Li, Lingjun

    2014-01-01

    Mass spectrometric imaging (MSI) is a powerful tool that grants the ability to investigate a broad mass range of molecules, from small molecules to large proteins, by creating detailed distribution maps of selected compounds. To date, MSI has demonstrated its versatility in the study of neurotransmitters and neuropeptides of different classes toward investigation of neurobiological functions and diseases. These studies have provided significant insight in neurobiology over the years and current technical advances are facilitating further improvements in this field. neurotransmitters, focusing specifically on the challenges and recent Herein, we advances of MSI of neurotransmitters. PMID:24568355

  18. Preparation of Single Cells for Imaging Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Berman, E S; Fortson, S L; Kulp, K S; Checchi, K D; Wu, L; Felton, J S; Wu, K J

    2007-10-24

    Characterizing chemical changes within single cells is important for determining fundamental mechanisms of biological processes that will lead to new biological insights and improved disease understanding. Imaging biological systems with mass spectrometry (MS) has gained popularity in recent years as a method for creating precise chemical maps of biological samples. In order to obtain high-quality mass spectral images that provide relevant molecular information about individual cells, samples must be prepared so that salts and other cell-culture components are removed from the cell surface and the cell contents are rendered accessible to the desorption beam. We have designed a cellular preparation protocol for imaging MS that preserves the cellular contents for investigation and removes the majority of the interfering species from the extracellular matrix. Using this method, we obtain excellent imaging results and reproducibility in three diverse cell types: MCF7 human breast cancer cells, Madin-Darby canine kidney (MDCK) cells, and NIH/3T3 mouse fibroblasts. This preparation technique allows routine imaging MS analysis of cultured cells, allowing for any number of experiments aimed at furthering scientific understanding of molecular processes within individual cells.

  19. Current cardiac imaging techniques for detection of left ventricular mass

    Directory of Open Access Journals (Sweden)

    Celebi Aksuyek S

    2010-06-01

    Full Text Available Abstract Estimation of left ventricular (LV mass has both prognostic and therapeutic value independent of traditional risk factors. Unfortunately, LV mass evaluation has been underestimated in clinical practice. Assessment of LV mass can be performed by a number of imaging modalities. Despite inherent limitations, conventional echocardiography has fundamentally been established as most widely used diagnostic tool. 3-dimensional echocardiography (3DE is now feasible, fast and accurate for LV mass evaluation. 3DE is also superior to conventional echocardiography in terms of LV mass assessment, especially in patients with abnormal LV geometry. Cardiovascular magnetic resonance (CMR and cardiovascular computed tomography (CCT are currently performed for LV mass assessment and also do not depend on cardiac geometry and display 3-dimensional data, as well. Therefore, CMR is being increasingly employed and is at the present standard of reference in the clinical setting. Although each method demonstrates advantages over another, there are also disadvantages to receive attention. Diagnostic accuracy of methods will also be increased with the introduction of more advanced systems. It is also likely that in the coming years new and more accurate diagnostic tests will become available. In particular, CMR and CCT have been intersecting hot topic between cardiology and radiology clinics. Thus, good communication and collaboration between two specialties is required for selection of an appropriate test.

  20. Deep learning for tumor classification in imaging mass spectrometry.

    Science.gov (United States)

    Behrmann, Jens; Etmann, Christian; Boskamp, Tobias; Casadonte, Rita; Kriegsmann, Jörg; Maaß, Peter

    2018-04-01

    Tumor classification using imaging mass spectrometry (IMS) data has a high potential for future applications in pathology. Due to the complexity and size of the data, automated feature extraction and classification steps are required to fully process the data. Since mass spectra exhibit certain structural similarities to image data, deep learning may offer a promising strategy for classification of IMS data as it has been successfully applied to image classification. Methodologically, we propose an adapted architecture based on deep convolutional networks to handle the characteristics of mass spectrometry data, as well as a strategy to interpret the learned model in the spectral domain based on a sensitivity analysis. The proposed methods are evaluated on two algorithmically challenging tumor classification tasks and compared to a baseline approach. Competitiveness of the proposed methods is shown on both tasks by studying the performance via cross-validation. Moreover, the learned models are analyzed by the proposed sensitivity analysis revealing biologically plausible effects as well as confounding factors of the considered tasks. Thus, this study may serve as a starting point for further development of deep learning approaches in IMS classification tasks. https://gitlab.informatik.uni-bremen.de/digipath/Deep_Learning_for_Tumor_Classification_in_IMS. jbehrmann@uni-bremen.de or christianetmann@uni-bremen.de. Supplementary data are available at Bioinformatics online.

  1. Mass-storage management for distributed image/video archives

    Science.gov (United States)

    Franchi, Santina; Guarda, Roberto; Prampolini, Franco

    1993-04-01

    The realization of image/video database requires a specific design for both database structures and mass storage management. This issue has addressed the project of the digital image/video database system that has been designed at IBM SEMEA Scientific & Technical Solution Center. Proper database structures have been defined to catalog image/video coding technique with the related parameters, and the description of image/video contents. User workstations and servers are distributed along a local area network. Image/video files are not managed directly by the DBMS server. Because of their wide size, they are stored outside the database on network devices. The database contains the pointers to the image/video files and the description of the storage devices. The system can use different kinds of storage media, organized in a hierarchical structure. Three levels of functions are available to manage the storage resources. The functions of the lower level provide media management. They allow it to catalog devices and to modify device status and device network location. The medium level manages image/video files on a physical basis. It manages file migration between high capacity media and low access time media. The functions of the upper level work on image/video file on a logical basis, as they archive, move and copy image/video data selected by user defined queries. These functions are used to support the implementation of a storage management strategy. The database information about characteristics of both storage devices and coding techniques are used by the third level functions to fit delivery/visualization requirements and to reduce archiving costs.

  2. Imaging of mass distribution in paper by electrography technique, (3)

    International Nuclear Information System (INIS)

    Tomimasu, Hiroshi; Baba, Susumu; Luner, P.

    1991-01-01

    Characteristics of photographic films and a TV monitor system as electron beam detectors were studied. A photographic film with thin emulsion layer showed a peak in the basis weight calibration curve because of its limited absorption of electron energy. On the other hand, a photographic film with thick emulsion layer showed no peak and provided wide measurable basis weight range. However, films with thick emulsion layer were found unsuitable for practical use since it requires very long development time. Real-time mass distribution image of a paper sample were obtained with a TV monitor system for transmission electron microscope combined with an image analyzer. The system can image the sample of 11x9 mm with spatial resolution of 20 μm at different electron accelerating voltages. The TV monitor system gave no peak in the basis weight calibration curve and provided wide measurable basis weight range. (author)

  3. Multiplex Mass Spectrometric Imaging with Polarity Switching for Concurrent Acquisition of Positive and Negative Ion Images

    Science.gov (United States)

    Korte, Andrew R.; Lee, Young Jin

    2013-06-01

    We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393-9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.

  4. Mass spectrometry imaging: a novel technology in rheumatology.

    Science.gov (United States)

    Rocha, Beatriz; Ruiz-Romero, Cristina; Blanco, Francisco J

    2017-01-01

    Mass spectrometry imaging (MSI) is used to determine the relative abundance and spatial distribution of biomolecules such as peptides, proteins, lipids and other organic compounds in tissue sections by their molecular masses. This technique provides a sensitive and label-free approach for high-resolution imaging, and is currently used in an increasing number of biomedical applications such as biomarker discovery, tissue classification and drug monitoring. Owing to technological advances in the past 5 years in diverse MSI strategies, this technology is expected to become a standard tool in clinical practice and provides information complementary to that obtained using existing methods. Given that MSI is able to extract mass-spectral signatures from pathological tissue samples, this technique provides a novel platform to study joint-related tissues affected by rheumatic diseases. In rheumatology, MSI has been performed on articular cartilage, synovium and bone to increase the understanding of articular destruction and to characterize diagnostic and prognostic biomarkers for osteoarthritis, rheumatoid arthritis and osteoporosis. In this Review, we provide an overview of MSI technology and of the studies in which joint tissues have been analysed by use of this methodology. This approach might increase knowledge of rheumatic pathologies and ultimately prompt the development of targeted strategies for their management.

  5. Topological mass of magnetic Skyrmions probed by ultrafast dynamic imaging

    International Nuclear Information System (INIS)

    Buettner, Felix

    2013-01-01

    In this thesis, we investigate the GHz dynamics of skyrmionic spin structures by means of pump-probe dynamic imaging to determine the equation of motion that governs the behavior of these technologically relevant spin structures. To achieve this goal, we first designed and optimized a perpendicular magnetic anisotropy CoB/Pt multilayer material for low magnetic pinning, as required for ultrafast pump-probe imaging experiments. Second, we developed an integrated sample design for X-ray holography capable of tracking relative magnetic positional changes down to 3 nm spatial resolution. These advances enabled us to image the trajectory of a single magnetic Skyrmion. We find that the motion is comprised of two gyrotropic modes, one clockwise and one counterclockwise. The existence of two modes shows that Skyrmions are massive quasiparticles. From their derived frequencies we find an inertial mass for the Skyrmion which is a factor of five larger than expected based on existing models for inertia in magnetism. Our results demonstrate that the mass of Skyrmions is based on a novel mechanism emerging from their confined nature, which is a direct consequence of their topology.

  6. Mass media image of selected instruments of economic develepment

    Directory of Open Access Journals (Sweden)

    Kruliš Ladislav

    2016-07-01

    Full Text Available The goal of this paper is twofold. Firstly, two instruments of economic development – investment incentives and cluster initiatives – were compared according to the frequency of their occurrence in selected mass media sources in the Czech Republic in the periods 2004-2005 and 2011-2012. Secondly, the mass media image of these two instruments of economic development was evaluated with respect to the frames deductively constructed from literature review. The findings pointed out a higher occurrence of the mass media articles/news dealing with investment incentives. These articles/news were, additionally, more controversial and covered a wider spectrum of frames. Politicians were a relatively more frequent type of actors who created the media message from the articles/news. On the contrary, the mass media articles/news concerning cluster initiatives typically created the frame of positive effects of clusters. The messages were told either by economic experts or by public authority representatives who were closely connected with cluster initiatives. Spatial origin of these messages was rather limited. The definitional vagueness, intangible and uncontroversial nature of cluster initiatives restrained their media appeal.

  7. New image of psychiatry, mass media impact and public relations.

    Science.gov (United States)

    Jakovljević, Miro; Tomić, Zoran; Maslov, Boris; Skoko, Iko

    2010-06-01

    The mass media has a powerful impact on public attitudes about mental health and psychiatry. The question of identity of psychiatry as a medical profession as well as of the future of psychiatry has been the subject of much controversial discussion. Psychiatry today has the historical opportunity to shape the future of mental health care, medicine and society. It has gained in scientific and professional status by the tremendous increase of knowledge and treatment skills. Psychiatry should build up new transdisciplinary and integrative image of a specialized profession, promote it and make it public. Good public relations are very important for the future of psychiatry.

  8. A novel ion imager for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Matsumoto, Kazuya; Miyata, Kenji; Nakamura, Tsutomu

    1993-01-01

    This paper describes a new area detector for secondary ion mass spectrometry (SIMS) ion microscope, and its performance. The operational principle is based on detecting the change in potential of a floating photodiode caused by the ion-induced secondary-electron emission and the incoming ion itself. The experiments demonstrated that 10 1 -10 5 aluminum ions per pixel can be detected with good linear response. Moreover, relative ion sensitivities from hydrogen to lead were constant within a factor of 2. The performance of this area detector provides the potential for detection of kiloelectronvolt ion images with current ion microscopy

  9. Imaging mass spectrometry tackles interfacial challenges in electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xiao-Ying

    2017-12-01

    Electrochemistry has played a significant role in many research fields. Owing to its sensitivity and selectivity, in situ electroanalysis has been widely used as a fast and economical means for achieving outstanding results. Although many spectroscopic techniques have been used in electrochemistry, the challenges to capture short-lived intermediate species as a result of electron transfer in the buried solid electrode and electrolyte solution interface remains a grand challenge. In situ imaging mass spectrometry (IMS) recently has been extended to capture transient species in electrochemistry. This review intends to summarize newest development of IMS and its applications in advancing fundamental electrochemistry.

  10. Image slicer manufacturing: from space application to mass production

    Science.gov (United States)

    Bonneville, Christophe; Cagnat, Jean-François; Laurent, Florence; Prieto, Eric; Ancourt, Gérard

    2004-09-01

    This presentation aims to show technical and industrial inputs to be taking into account for Image Slicer systems design and development for different types of projects from space application to mass production for multi-IFU instruments. Cybernétix has a strong experience of precision optics assembled thanks to molecular adhesion and have already manufactured 6 prototypes of image slicer subsystem (prototypes of NIRSPEC-IFU, IFS for JWST, MUSE ...) in collaboration with the Laboratoire d"Astrophysique de Marseille (LAM) and the Centre de Recherche Astronomique de Lyon (CRAL). After a brief presentation of the principle of manufacturing and assembly, we will focus on the different performances achieved in our prototypes of slicer mirrors, pupil and slit mirrors lines: an accuracy on centre of curvature position better than 15 arsec has been obtained for a stack of 30 slices. The contribution of the slice stacking to this error is lower than 4 arcsec. In spite of very thin surfaces (~ 0.9 x 40 mm for instance), a special process allows to guarantee a surface roughness about 5 nm and very few digs on the slice borders. The WFE of the mini-mirror can also be measured at a stage of the manufacturing. Different environmental tests have shown the withstanding of these assemblies to cryogenic temperature (30 K). Then, we will describe the different solutions (spherical, flat, cylindrical surfaces) and characteristics of an image slicer that can influence difficulties of manufacturing and metrology, cost, schedule and risks with regard to fabrication. Finally, the study of a mass production plan for MUSE (CRAL) composed of 24 Image Slicers of 38 slices, that"s to say 912 slices, will be exposed as an example of what can be do for multi-module instruments.

  11. Rock mass seismic imaging around the ONKALO tunnel, Olkiluoto 2007

    International Nuclear Information System (INIS)

    Cosma, C.; Cozma, M.; Balu, L.; Enescu, N.

    2008-11-01

    Posiva Oy prepares for disposal of spent nuclear fuel in bedrock focusing in Olkiluoto, Eurajoki. This is in accordance of the application filed in 1999, the Decision-in-Principle of the State Council in 2000, and ratification by the Parliament in 2001. Vibrometric Oy has performed a tunnel seismic survey in ONKALO access tunnel on a 100 m line in December 2007. Tunnel length (chainage) was 1720 - 1820 m (vertical depth 170 - 180 m). Measurement applied 120 source positions at 1 m spacing, and on the both ends at 4 m spacing. Electromechanical Vibsist-20 tool was used as the source. Hammer produced 15.36 s sweeps. Signal was recorded with 2-component geophone assemblies, installed in 400 mm long, 45 mm drillholes in the tunnel wall. Sweeps were recorded with Summit II seismograph and decoded to seismic traces. Also percussion drill rig, which is used in drilling the blasting holes in tunnel excavation, was tested from a 100-m distance as a seismic source. Signal is equally good as from actual seismic source, and may be applied later on for production. Obtained seismic results were processed with tomographic reconstruction of the first arrivals to P and S wave refraction tomograms, and to tomograms of Young's modulus and Shear Modulus. The obtained values correspond the typical levels known from Olkiluoto. There are indications of lower velocity near tunnel wall, but resolution is not adequate for further interpretation. Some variation of velocity is detected in the rock mass. Seismic data was also processed with normal reflection profile interpretation and migrated. As a result there was obtained reflection images to a 100-m distance from the tunnel. Several reflecting events were observed in the rock mass. Features making an angle of 30 deg or more with tunnel axis can be imaged from distances of tens of metres. Vertical fractures perpendicular to tunnel can be imaged only near the tunnel. Gently dipping features can be imaged below and above. Images are 2D, i

  12. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  13. Murine cutaneous leishmaniasis investigated by MALDI mass spectrometry imaging.

    Science.gov (United States)

    Negrão, Fernanda; de O Rocha, Daniele F; Jaeeger, Caroline F; Rocha, Francisca J S; Eberlin, Marcos N; Giorgio, Selma

    2017-09-26

    Imaging mass spectrometry (IMS) is recognized as a powerful tool to investigate the spatial distribution of untargeted or targeted molecules of a wide variety of samples including tissue sections. Leishmania is a protozoan parasite that causes different clinical manifestations in mammalian hosts. Leishmaniasis is a major public health risk in different continents and represents one of the most important neglected diseases. Cutaneous lesions from mice experimentally infected with Leishmania spp. were investigated by matrix-assisted laser desorption ionization MS using the SCiLS Lab software for statistical analysis. Being applied to cutaneous leishmaniasis (CL) for the first time, MALDI-IMS was used to search for peptides and low molecular weight proteins (2-10 kDa) as candidates for potential biomarkers. Footpad sections of Balb/c mice infected with (i) Leishmania amazonensis or (ii) Leishmania major were imaged. The comparison between healthy and infected skin highlighted a set of twelve possible biomarker proteins for L. amazonenis and four proteins for L. major. Further characterization of these proteins could reveal how these proteins act in pathology progression and confirm their values as biomarkers.

  14. Imaging and mapping of mouse bone using MALDI-imaging mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yoko Fujino

    2016-12-01

    Full Text Available Matrix-assisted laser desorption/ionization-imaging mass spectrometry (MALDI-IMS is an advanced method used globally to analyze the distribution of biomolecules on tissue cryosections without any probes. In bones, however, hydroxyapatite crystals make it difficult to determine the distribution of biomolecules using MALDI-IMS. Additionally, there is limited information regarding the use of this method to analyze bone tissues. To determine whether MALDI-IMS analysis of bone tissues can facilitate comprehensive mapping of biomolecules in mouse bone, we first dissected femurs and tibiae from 8-week-old male mice and characterized the quality of multiple fixation and decalcification methods for preparation of the samples. Cryosections were mounted on indium tin oxide-coated glass slides, dried, and then a matrix solution was sprayed on the tissue surface. Images were acquired using an iMScope at a mass-to-charge range of 100–1000. Hematoxylin-eosin, Alcian blue, Azan, and periodic acid-Schiff staining of adjacent sections was used to evaluate histological and histochemical features. Among the various fixation and decalcification conditions, sections from trichloroacetic acid-treated samples were most suitable to examine both histology and comprehensive MS images. However, histotypic MS signals were detected in all sections. In addition to the MS images, phosphocholine was identified as a candidate metabolite. These results indicate successful detection of biomolecules in bone using MALDI-IMS. Although analytical procedures and compositional adjustment regarding the performance of the device still require further development, IMS appears to be a powerful tool to determine the distribution of biomolecules in bone tissues. Keywords: Matrix-assisted laser desorption/ionization-imaging mass spectrometry, Tissue cryosection, Bone, Fixation, Decalcification

  15. Improved mass resolution and mass accuracy in TOF-SIMS spectra and images using argon gas cluster ion beams.

    Science.gov (United States)

    Shon, Hyun Kyong; Yoon, Sohee; Moon, Jeong Hee; Lee, Tae Geol

    2016-06-09

    The popularity of argon gas cluster ion beams (Ar-GCIB) as primary ion beams in time-of-flight secondary ion mass spectrometry (TOF-SIMS) has increased because the molecular ions of large organic- and biomolecules can be detected with less damage to the sample surfaces. However, Ar-GCIB is limited by poor mass resolution as well as poor mass accuracy. The inferior quality of the mass resolution in a TOF-SIMS spectrum obtained by using Ar-GCIB compared to the one obtained by a bismuth liquid metal cluster ion beam and others makes it difficult to identify unknown peaks because of the mass interference from the neighboring peaks. However, in this study, the authors demonstrate improved mass resolution in TOF-SIMS using Ar-GCIB through the delayed extraction of secondary ions, a method typically used in TOF mass spectrometry to increase mass resolution. As for poor mass accuracy, although mass calibration using internal peaks with low mass such as hydrogen and carbon is a common approach in TOF-SIMS, it is unsuited to the present study because of the disappearance of the low-mass peaks in the delayed extraction mode. To resolve this issue, external mass calibration, another regularly used method in TOF-MS, was adapted to enhance mass accuracy in the spectrum and image generated by TOF-SIMS using Ar-GCIB in the delayed extraction mode. By producing spectra analyses of a peptide mixture and bovine serum albumin protein digested with trypsin, along with image analyses of rat brain samples, the authors demonstrate for the first time the enhancement of mass resolution and mass accuracy for the purpose of analyzing large biomolecules in TOF-SIMS using Ar-GCIB through the use of delayed extraction and external mass calibration.

  16. Mass Spectrometry Imaging for the Investigation of Intratumor Heterogeneity.

    Science.gov (United States)

    Balluff, B; Hanselmann, M; Heeren, R M A

    2017-01-01

    One of the big clinical challenges in the treatment of cancer is the different behavior of cancer patients under guideline therapy. An important determinant for this phenomenon has been identified as inter- and intratumor heterogeneity. While intertumor heterogeneity refers to the differences in cancer characteristics between patients, intratumor heterogeneity refers to the clonal and nongenetic molecular diversity within a patient. The deciphering of intratumor heterogeneity is recognized as key to the development of novel therapeutics or treatment regimens. The investigation of intratumor heterogeneity is challenging since it requires an untargeted molecular analysis technique that accounts for the spatial and temporal dynamics of the tumor. So far, next-generation sequencing has contributed most to the understanding of clonal evolution within a cancer patient. However, it falls short in accounting for the spatial dimension. Mass spectrometry imaging (MSI) is a powerful tool for the untargeted but spatially resolved molecular analysis of biological tissues such as solid tumors. As it provides multidimensional datasets by the parallel acquisition of hundreds of mass channels, multivariate data analysis methods can be applied for the automated annotation of tissues. Moreover, it integrates the histology of the sample, which enables studying the molecular information in a histopathological context. This chapter will illustrate how MSI in combination with statistical methods and histology has been used for the description and discovery of intratumor heterogeneity in different cancers. This will give evidence that MSI constitutes a unique tool for the investigation of intratumor heterogeneity, and could hence become a key technology in cancer research. © 2017 Elsevier Inc. All rights reserved.

  17. [Application of Imaging Mass Spectrometry for Drug Discovery].

    Science.gov (United States)

    Hayasaka, Takahiro

    2016-01-01

    Imaging mass spectrometry (IMS) can reveal the distribution of biomolecules on tissue sections. In this process, the biomolecules are directly ionized within tissue sections using matrix-assisted laser desorption/ionization, and then their distribution is visualized by pseudo-color based on the relative signal intensity. The biomolecules, such as fatty acids, phospholipids, glycolipids, peptides, proteins, and neurotransmitters, have been analyzed at a spatial resolution of 5 μm. A special instrument for IMS analysis was developed by Shimadzu. The IMS analysis does not require the labeling of biomolecules and is capable of analyzing all the ionized biomolecules. Interest in this method has expanded to many research fields, including biology, agriculture, medicine, and pharmacology. The technique is especially relevant to the drug discovery process. As practiced currently, drug discovery is expensive and time consuming, requiring the preparation of probes for each drug and its metabolites, followed by systematic probe tracking in animal models. The IMS technique is expected to overcome these drawbacks by revealing the distribution of drugs and their metabolites using only a single analysis. In this symposium, I introduced the methodology and applications of IMS and discussed the feasibility of its application to drug discovery in the near future.

  18. Origins and processes of groundwater salinization in the urban coastal aquifers of Recife (Pernambuco, Brazil): A multi-isotope approach

    International Nuclear Information System (INIS)

    Cary, Lise; Petelet-Giraud, Emmanuelle; Bertrand, Guillaume; Kloppmann, Wolfram; Aquilina, Luc; Martins, Veridiana; Hirata, Ricardo; Montenegro, Suzana; Pauwels, Hélène; Chatton, Eliot; Franzen, Melissa; Aurouet, Axel; Lasseur, Eric; Picot, Géraldine; Guerrot, Catherine; Fléhoc, Christine

    2015-01-01

    In the coastal multilayer aquifer system of a highly urbanized southern city (Recife, Brazil), where groundwaters are affected by salinization, a multi-isotope approach (Sr, B, O, H) was used to investigate the sources and processes of salinization. The high diversity of the geological bodies, built since the Atlantic opening during the Cretaceous, highly constrains the heterogeneity of the groundwater chemistry, e.g. Sr isotope ratios, and needs to be integrated to explain the salinization processes and groundwater pathways. A paleoseawater intrusion, most probably the 120 ky B.P. Pleistocene marine transgression, and cationic exchange are clearly evidenced in the most salinized parts of the Cabo and Beberibe aquifers. All 87 Sr/ 86 Sr values are above the past and present-day seawater signatures, meaning that the Sr isotopic signature is altered due to additional Sr inputs from dilution with different freshwaters, and water–rock interactions. Only the Cabo aquifer presents a well-delimitated area of Na-HCO 3 water typical of a freshening process. The two deep aquifers also display a broad range of B concentrations and B isotope ratios with values among the highest known to date (63–68.5‰). This suggests multiple sources and processes affecting B behavior, among which mixing with saline water, B sorption on clays and mixing with wastewater. The highly fractionated B isotopic values were explained by infiltration of relatively salty water with B interacting with clays, pointing out the major role played by (palaeo)-channels for the deep Beberibe aquifer recharge. Based on an increase of salinity at the end of the dry season, a present-day seawater intrusion is identified in the surficial Boa Viagem aquifer. Our conceptual model presents a comprehensive understanding of the major groundwater salinization pathways and processes, and should be of benefit for other southern Atlantic coastal aquifers to better address groundwater management issues. - Highlights:

  19. Origins and processes of groundwater salinization in the urban coastal aquifers of Recife (Pernambuco, Brazil): A multi-isotope approach

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Lise, E-mail: l.cary@brgm.fr [BRGM French Geological Survey, 3 Avenue Claude Guillemin, 45060 Orléans Cedex 2 (France); Petelet-Giraud, Emmanuelle [BRGM French Geological Survey, 3 Avenue Claude Guillemin, 45060 Orléans Cedex 2 (France); Bertrand, Guillaume [Institute of Geosciences, University of São Paulo, Rua do Lago, 562 Butantã, 05508-080 Sao Paulo (Brazil); Kloppmann, Wolfram [BRGM French Geological Survey, 3 Avenue Claude Guillemin, 45060 Orléans Cedex 2 (France); Aquilina, Luc [OSUR-Géosciences Rennes, Université Rennes 1 — CNRS, 35000 Rennes (France); Martins, Veridiana; Hirata, Ricardo [Institute of Geosciences, University of São Paulo, Rua do Lago, 562 Butantã, 05508-080 Sao Paulo (Brazil); Montenegro, Suzana [Civil Engineering Department, Federal University of Pernambuco, 50740 Recife, PE Brazil (Brazil); Pauwels, Hélène [BRGM French Geological Survey, 3 Avenue Claude Guillemin, 45060 Orléans Cedex 2 (France); Chatton, Eliot [OSUR-Géosciences Rennes, Université Rennes 1 — CNRS, 35000 Rennes (France); Franzen, Melissa [CPRM, Brazilian Geologic Survey, Avenida Sul 2291, Recife PE (Brazil); Aurouet, Axel [Géo-Hyd, 101 rue Jacques Charles, 45160 Olivet (France); Lasseur, Eric; Picot, Géraldine; Guerrot, Catherine; Fléhoc, Christine [BRGM French Geological Survey, 3 Avenue Claude Guillemin, 45060 Orléans Cedex 2 (France); and others

    2015-10-15

    In the coastal multilayer aquifer system of a highly urbanized southern city (Recife, Brazil), where groundwaters are affected by salinization, a multi-isotope approach (Sr, B, O, H) was used to investigate the sources and processes of salinization. The high diversity of the geological bodies, built since the Atlantic opening during the Cretaceous, highly constrains the heterogeneity of the groundwater chemistry, e.g. Sr isotope ratios, and needs to be integrated to explain the salinization processes and groundwater pathways. A paleoseawater intrusion, most probably the 120 ky B.P. Pleistocene marine transgression, and cationic exchange are clearly evidenced in the most salinized parts of the Cabo and Beberibe aquifers. All {sup 87}Sr/{sup 86}Sr values are above the past and present-day seawater signatures, meaning that the Sr isotopic signature is altered due to additional Sr inputs from dilution with different freshwaters, and water–rock interactions. Only the Cabo aquifer presents a well-delimitated area of Na-HCO{sub 3} water typical of a freshening process. The two deep aquifers also display a broad range of B concentrations and B isotope ratios with values among the highest known to date (63–68.5‰). This suggests multiple sources and processes affecting B behavior, among which mixing with saline water, B sorption on clays and mixing with wastewater. The highly fractionated B isotopic values were explained by infiltration of relatively salty water with B interacting with clays, pointing out the major role played by (palaeo)-channels for the deep Beberibe aquifer recharge. Based on an increase of salinity at the end of the dry season, a present-day seawater intrusion is identified in the surficial Boa Viagem aquifer. Our conceptual model presents a comprehensive understanding of the major groundwater salinization pathways and processes, and should be of benefit for other southern Atlantic coastal aquifers to better address groundwater management issues

  20. A trial of selective imaging for the breast mass shadow by computed radiography

    International Nuclear Information System (INIS)

    Muramatsu, Yukio; Anan, Mitsuhiro; Tanaka, Takashi; Matsue, Hiroto; Yamada, Tatsuya

    1990-01-01

    CR has ability to make many kinds of images by several imaging processings. Especially, gradation processing is more important than frequency processing to make images in CR mammography. We developed new method to image breast masses selectively with new gradation processing and tried it for 18 patients over sixty years old with breast cancer. All of breast mass shadows were separated selectively from other parencymal shadow. So, we conclude that the auto-recognition of breast mass shadow can be possible in near future in CR system. (author)

  1. The role of three-dimensional imaging in evaluation of the sinonasal mass

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Sue Yon; Sung, Ki Joon; Kim, Young Ju; Hong, In Soo; Kim, Myung Soon; Oh, Jin Hwan; Paik, Seog In [Yonsei Univ. College of Medicine, Wonju (Korea, Republic of)

    1996-01-01

    To investigate the role of 3D imaging in the sinonasal mass. Twenty patients with sinonasal mass(squamous cell carcinoma[n=6], spindle cell carcinoma[n=1], angiomatous polyp[n=1], giant cell reparative granuloma[n=1], non-Hodgkin's lymphjoma[n=1], melanoma[n=1], angiofibroma[n=1], inverted papilloma[n=1]) were studied with spiral CT. Reconstruction of surface rendered 3D images and segmentations were performed and compared with the 2D image. The 3D images enabled easy understanding of the characteristics of the mass in 12 casese. The 3D images displayed pathway of tumor extension in 5 cases and were helpful in assessing the primary site of the mass in 3 cases. In two cases with encasement of ICA by the mass, assessment of relationship between the mass and vessels were possible through the segmentation. The 3D image, as an adjunct to the 2D image, can help to evaluate the virtual appearance of bony change, the degree of extension of mass, the spreading route, the evaluation of origin site. It also provides valuable 3-dimensional conception of the mass, especially for the surgeon.

  2. STRUCTURE TENSOR IMAGE FILTERING USING RIEMANNIAN L1 AND L∞ CENTER-OF-MASS

    Directory of Open Access Journals (Sweden)

    Jesus Angulo

    2014-06-01

    Full Text Available Structure tensor images are obtained by a Gaussian smoothing of the dyadic product of gradient image. These images give at each pixel a n×n symmetric positive definite matrix SPD(n, representing the local orientation and the edge information. Processing such images requires appropriate algorithms working on the Riemannian manifold on the SPD(n matrices. This contribution deals with structure tensor image filtering based on Lp geometric averaging. In particular, L1 center-of-mass (Riemannian median or Fermat-Weber point and L∞ center-of-mass (Riemannian circumcenter can be obtained for structure tensors using recently proposed algorithms. Our contribution in this paper is to study the interest of L1 and L∞ Riemannian estimators for structure tensor image processing. In particular, we compare both for two image analysis tasks: (i structure tensor image denoising; (ii anomaly detection in structure tensor images.

  3. The mass remote sensing image data management based on Oracle InterMedia

    Science.gov (United States)

    Zhao, Xi'an; Shi, Shaowei

    2013-07-01

    With the development of remote sensing technology, getting the image data more and more, how to apply and manage the mass image data safely and efficiently has become an urgent problem to be solved. According to the methods and characteristics of the mass remote sensing image data management and application, this paper puts forward to a new method that takes Oracle Call Interface and Oracle InterMedia to store the image data, and then takes this component to realize the system function modules. Finally, it successfully takes the VC and Oracle InterMedia component to realize the image data storage and management.

  4. Determination of geographic provenance of cotton fibres using multi-isotope profiles and multivariate statistical analysis

    Science.gov (United States)

    Daeid, N. Nic; Meier-Augenstein, W.; Kemp, H. F.

    2012-04-01

    The analysis of cotton fibres can be particularly challenging within a forensic science context where discrimination of one fibre from another is of importance. Normally cotton fibre analysis examines the morphological structure of the recovered material and compares this with that of a known fibre from a particular source of interest. However, the conventional microscopic and chemical analysis of fibres and any associated dyes is generally unsuccessful because of the similar morphology of the fibres. Analysis of the dyes which may have been applied to the cotton fibre can also be undertaken though this can be difficult and unproductive in terms of discriminating one fibre from another. In the study presented here we have explored the potential for Isotope Ratio Mass Spectrometry (IRMS) to be utilised as an additional tool for cotton fibre analysis in an attempt to reveal further discriminatory information. This work has concentrated on un-dyed cotton fibres of known origin in order to expose the potential of the analytical technique. We report the results of a pilot study aimed at testing the hypothesis that multi-element stable isotope analysis of cotton fibres in conjunction with multivariate statistical analysis of the resulting isotopic abundance data using well established chemometric techniques permits sample provenancing based on the determination of where the cotton was grown and as such will facilitate sample discrimination. To date there is no recorded literature of this type of application of IRMS to cotton samples, which may be of forensic science relevance.

  5. Automated, feature-based image alignment for high-resolution imaging mass spectrometry of large biological samples

    NARCIS (Netherlands)

    Broersen, A.; Liere, van R.; Altelaar, A.F.M.; Heeren, R.M.A.; McDonnell, L.A.

    2008-01-01

    High-resolution imaging mass spectrometry of large biological samples is the goal of several research groups. In mosaic imaging, the most common method, the large sample is divided into a mosaic of small areas that are then analyzed with high resolution. Here we present an automated alignment

  6. Meet interesting abbreviations in clinical mass spectrometry: from compound classification by REIMS to multimodal and mass spectrometry imaging (MSI)

    Czech Academy of Sciences Publication Activity Database

    Luptáková, Dominika; Pluháček, Tomáš; Palyzová, Andrea; Přichystal, Jakub; Balogh, J.; Lemr, Karel; Juránek, I.; Havlíček, Vladimír

    2017-01-01

    Roč. 61, č. 3 (2017), s. 353-360 ISSN 0001-723X R&D Projects: GA MŠk(CZ) LO1509; GA ČR(CZ) GA16-20229S Institutional support: RVO:61388971 Keywords : REIMS * multimodal * mass spectrometry imaging Subject RIV: EE - Microbiology, Virology OBOR OECD: Microbiology Impact factor: 0.673, year: 2016

  7. Multi isotopic characterization (Li-Cu-Zn-Pb) of waste waters pollution in a small watershed (Loire River basin, France)

    Science.gov (United States)

    Millot, R.; Desaulty, A. M.; Perret, S.; Bourrain, X.

    2016-12-01

    The goal of this study is to use multi-isotopic signature to track the pollution in surface waters, and to understand the complex processes causing the metals mobilization and transport in the environment. In the present study, we investigate waste water releases from a hospital water treatment plant and its potential impact in a small river basin near Orléans in France (Egoutier watershed: 15 km²and 5 km long). We decided to monitor this small watershed which is poorly urbanized in the Loire river basin. Its spring is located in a pristine area (forested area), while it is only impacted some kilometers further by the releases rich in metals coming from a hospital water treatment plant. A sampling of these liquid effluents as well as dissolved load and sediment from upstream to downstream was realized and their concentrations and isotopic data were determined. Isotopic ratios were measured using a MC-ICP-MS at BRGM, after a specific protocol of purification for each isotopic systematics. Lithium isotopic compositions are rather homogeneous in river waters along the main course of the stream. The waste water signal is very different from the natural background with significant heavy lithium contribution (high δ7Li). Lead isotopic compositions are rather homogenous in river waters and sediments with values close to geologic background. For Zn, the sediments with high concentrations and depleted isotopic compositions (low δ66Zn), typical of an anthropic pollution, are strongly impacted. The analyses of Cu isotopes in sediments show the impact of waster waters, but also isotopic fractionations due to redox processes in the watershed. To better understand these processes controlling the release of metals in water, sequential extractions on sediments are in progress under laboratory conditions and will provide important constraints for metal distribution in this river basin.

  8. Mirion--a software package for automatic processing of mass spectrometric images.

    Science.gov (United States)

    Paschke, C; Leisner, A; Hester, A; Maass, K; Guenther, S; Bouschen, W; Spengler, B

    2013-08-01

    Mass spectrometric imaging (MSI) techniques are of growing interest for the Life Sciences. In recent years, the development of new instruments employing ion sources that are tailored for spatial scanning allowed the acquisition of large data sets. A subsequent data processing, however, is still a bottleneck in the analytical process, as a manual data interpretation is impossible within a reasonable time frame. The transformation of mass spectrometric data into spatial distribution images of detected compounds turned out to be the most appropriate method to visualize the results of such scans, as humans are able to interpret images faster and easier than plain numbers. Image generation, thus, is a time-consuming and complex yet very efficient task. The free software package "Mirion," presented in this paper, allows the handling and analysis of data sets acquired by mass spectrometry imaging. Mirion can be used for image processing of MSI data obtained from many different sources, as it uses the HUPO-PSI-based standard data format imzML, which is implemented in the proprietary software of most of the mass spectrometer companies. Different graphical representations of the recorded data are available. Furthermore, automatic calculation and overlay of mass spectrometric images promotes direct comparison of different analytes for data evaluation. The program also includes tools for image processing and image analysis.

  9. Foodomics imaging by mass spectrometry and magnetic resonance.

    Science.gov (United States)

    Canela, Núria; Rodríguez, Miguel Ángel; Baiges, Isabel; Nadal, Pedro; Arola, Lluís

    2016-07-01

    This work explores the use of advanced imaging MS (IMS) and magnetic resonance imaging (MRI) techniques in food science and nutrition to evaluate food sensory characteristics, nutritional value and health benefits. Determining the chemical content and applying imaging tools to food metabolomics offer detailed information about food quality, safety, processing, storage and authenticity assessment. IMS and MRI are powerful analytical systems with an excellent capability for mapping the distribution of many molecules, and recent advances in these platforms are reviewed and discussed, showing the great potential of these techniques for small molecule-based food metabolomics research. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Technological Development of High-Performance MALDI Mass Spectrometry Imaging for the Study of Metabolic Biology

    Energy Technology Data Exchange (ETDEWEB)

    Feenstra, Adam D. [Iowa State Univ., Ames, IA (United States)

    2016-12-17

    This thesis represents efforts made in technological developments for the study of metabolic biology in plants, specifically maize, using matrix-assisted laser desorption/ ionization-mass spectrometry imaging.

  11. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  12. The Image of Public Relations in Mass Comm Texts.

    Science.gov (United States)

    Cline, Carolyn

    1982-01-01

    Compared public relations sections in 12 introductory mass communication texts and found a confusion about the relationship of advertising and public relations, a lack of historical background, and an antipublic relations stance. Journal available from Communication Research Associates, 7100 Baltimore Blvd., Suite 500, College Park, MD 20740; sc…

  13. Visualization of metallodrugs in single cells by secondary ion mass spectrometry imaging.

    Science.gov (United States)

    Wu, Kui; Jia, Feifei; Zheng, Wei; Luo, Qun; Zhao, Yao; Wang, Fuyi

    2017-07-01

    Secondary ion mass spectrometry, including nanoscale secondary ion mass spectrometry (NanoSIMS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), has emerged as a powerful tool for biological imaging, especially for single cell imaging. SIMS imaging can provide information on subcellular distribution of endogenous and exogenous chemicals, including metallodrugs, from membrane through to cytoplasm and nucleus without labeling, and with high spatial resolution and chemical specificity. In this mini-review, we summarize recent progress in the field of SIMS imaging, particularly in the characterization of the subcellular distribution of metallodrugs. We anticipate that the SIMS imaging method will be widely applied to visualize subcellular distributions of drugs and drug candidates in single cells, exerting significant influence on early drug evaluation and metabolism in medicinal and pharmaceutical chemistry. Recent progress of SIMS applications in characterizing the subcellular distributions of metallodrugs was summarized.

  14. Direct molecular analysis of whole-body animal tissue sections by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Reyzer, Michelle L; Chaurand, Pierre; Angel, Peggi M; Caprioli, Richard M

    2010-01-01

    The determination of the localization of various compounds in a whole animal is valuable for many applications, including pharmaceutical absorption, distribution, metabolism, and excretion (ADME) studies and biomarker discovery. Imaging mass spectrometry is a powerful tool for localizing compounds of biological interest with molecular specificity and relatively high resolution. Utilizing imaging mass spectrometry for whole-body animal sections offers considerable analytical advantages compared to traditional methods, such as whole-body autoradiography, but the experiment is not straightforward. This chapter addresses the advantages and unique challenges that the application of imaging mass spectrometry to whole-body animal sections entails, including discussions of sample preparation, matrix application, signal normalization, and image generation. Lipid and protein images obtained from whole-body tissue sections of mouse pups are presented along with detailed protocols for the experiments.

  15. Small renal mass cryosurgery: Imaging and vascular changes

    NARCIS (Netherlands)

    Lagerveld, B.W.

    2014-01-01

    The combined use of a fluorescent casting technique, cryomicrotome imaging, and 3-D computer analysis as a new static method for visualizing and reconstructing the vascular anatomy in a porcine renal model was studied. The arterial blood supply in 3-D at a resolution of up to 50μm of the whole could

  16. Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies

    Czech Academy of Sciences Publication Activity Database

    Kaftan, Filip; Vrkoslav, Vladimír; Kynast, P.; Kulkarni, P.; Böcker, S.; Cvačka, Josef; Knaden, M.; Svatoš, Aleš

    2014-01-01

    Roč. 49, č. 3 (2014), s. 223-232 ISSN 1076-5174 R&D Projects: GA ČR GA203/09/0139 Institutional support: RVO:61388963 Keywords : MALDI * laser desorption * mass spectrometric imaging * fruit flies * neutral lipids * sex pheromones * mass shift correction Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.379, year: 2014

  17. Mutual coherent properties of the images of the quasar microlensed by star mass

    International Nuclear Information System (INIS)

    Verkhoglyadova, O.P.; Mandzhos, A.V.

    1988-01-01

    The paper investigates the problem of mutual coherence of the radiation from two quasar images formed by a single point-mass gravitational lens with the mass of the order of solar mass. The expression for coherence degree is derived by asymptotic expansion in frequency. The coherence degree magnitude attains, in some cases, the values of 0.01-0.02 in the radio-frequency range. 9 refs.; 2 figs.; 2 tabs

  18. Disentangling the complexity of nitrous oxide cycling in coastal sediments: Results from a novel multi-isotope approach

    Science.gov (United States)

    Wankel, S. D.; Buchwald, C.; Charoenpong, C.; Ziebis, W.

    2014-12-01

    with water in influencing the O isotope composition of N2O from the sediment-water interface. A steady-state multi-isotope flux model will help to constraining rates and isotope effects of these processes and improve our understanding of the dynamics and pathways of N2O production and emission under varying scenarios of environmental change.

  19. ESUR recommendations for MR imaging of the sonographically indeterminate adnexal mass: an update

    Energy Technology Data Exchange (ETDEWEB)

    Forstner, Rosemarie [Paracelsus Medical University, Department of Radiology, Landeskliniken Salzburg, Salzburg (Austria); Thomassin-Naggara, Isabelle [Sorbonne Universites, UPMC Univ. Paris 06, Institut Universitaire de Cancerologie, Assistance Publique - Hopitaux de Paris (AP-HP), Hopital Tenon, Service de Radiologie, Paris (France); Cunha, Teresa Margarida [Servico de Radiologia, Instituto Portugues de Oncologia de Lisboa Francisco Gentil, Lisboa (Portugal); Kinkel, Karen [Clinique des Grangettes, Institut de Radiologie, Chene-Bougeries (Switzerland); Masselli, Gabriele [Sapienza University, Radiology Department, Rome (Italy); Kubik-Huch, Rahel [Kantonsspital Baden, Institut of Radiology, Departement of Medical Services, Baden (Switzerland); Spencer, John A. [St James' s University Hospital, Department of Radiology, Leeds (United Kingdom); Rockall, Andrea [The Royal Marsden Hospital NHS Foundation Trust, Consultant Radiologist, London (United Kingdom); Visiting Professor, Imperial College, London (United Kingdom)

    2017-06-15

    An update of the 2010 published ESUR recommendations of MRI of the sonographically indeterminate adnexal mass integrating functional techniques is provided. An algorithmic approach using sagittal T2 and a set of transaxial T1 and T2WI allows categorization of adnexal masses in one of the following three types according to its predominant signal characteristics. T1 'bright' masses due to fat or blood content can be simply and effectively determined using a combination of T1W, T2W and FST1W imaging. When there is concern for a solid component within such a mass, it requires additional assessment as for a complex cystic or cystic-solid mass. For low T2 solid adnexal masses, DWI is now recommended. Such masses with low DWI signal on high b value image (e.g. > b 1000 s/mm{sup 2}) can be regarded as benign. Any other solid adnexal mass, displaying intermediate or high DWI signal, requires further assessment by contrast-enhanced (CE)T1W imaging, ideally with DCE MR, where a type 3 curve is highly predictive of malignancy. For complex cystic or cystic-solid masses, both DWI and CET1W - preferably DCE MRI - is recommended. Characteristic enhancement curves of solid components can discriminate between lesions that are highly likely malignant and highly likely benign. (orig.)

  20. Mass Processing of Sentinel-1 Images for Maritime Surveillance

    Directory of Open Access Journals (Sweden)

    Carlos Santamaria

    2017-07-01

    Full Text Available The free, full and open data policy of the EU’s Copernicus programme has vastly increased the amount of remotely sensed data available to both operational and research activities. However, this huge amount of data calls for new ways of accessing and processing such “big data”. This paper focuses on the use of Copernicus’s Sentinel-1 radar satellite for maritime surveillance. It presents a study in which ship positions have been automatically extracted from more than 11,500 Sentinel-1A images collected over the Mediterranean Sea, and compared with ship position reports from the Automatic Identification System (AIS. These images account for almost all the Sentinel-1A acquisitions taken over the area during the two-year period from the start of the operational phase in October 2014 until September 2016. A number of tools and platforms developed at the European Commission’s Joint Research Centre (JRC that have been used in the study are described in the paper. They are: (1 Search for Unidentified Maritime Objects (SUMO, a tool for ship detection in Synthetic Aperture Radar (SAR images; (2 the JRC Earth Observation Data and Processing Platform (JEODPP, a platform for efficient storage and processing of large amounts of satellite images; and (3 Blue Hub, a maritime surveillance GIS and data fusion platform. The paper presents the methodology and results of the study, giving insights into the new maritime surveillance knowledge that can be gained by analysing such a large dataset, and the lessons learnt in terms of handling and processing the big dataset.

  1. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  2. Evaluation of methods for MR imaging of human right ventricular heart volumes and mass

    International Nuclear Information System (INIS)

    Jauhiainen, T.; Jaervinen, V.M.; Hekali, P.E.

    2002-01-01

    Purpose: To assess the utility of two different imaging directions in the evaluation of human right ventricular (RV) heart volumes and mass with MR imaging; to compare breath-hold vs. non-breath-hold imaging in volume analysis; and to compare turbo inversion recovery imaging (TIR) with gradient echo imaging in RV mass measurement. Material and Methods: We examined 12 healthy volunteers (age 27-59 years). Breath-hold gradient echo MR imaging was performed in two imaging planes: 1) perpendicular to the RV inflow tract (RVIT view), and 2) in the transaxial view (TA view). The imaging was repeated in the TA view while the subjects were breathing freely. To analyze RV mass using TIR images, the RV was again imaged at end-diastole using the two views. The RV end-diastolic cavity (RVEDV) and muscle volume as well as end-systolic cavity volume (RVESV) were determined with the method of discs. All measurements were done blindly twice to assess repeatability of image analysis. To assess reproducibility of the measurements, 6 of the subjects were imaged twice at an interval of 5-9 weeks. Results: RVEDV averaged 133.2 ml, RVESV 61.5 ml and the RVmass 46.2 g in the RVIT view and 119.9 ml, 56.9 ml and 38.3 g in the TA view, respectively. The volumes obtained with breath-holding were slightly but not significantly smaller than the volumes obtained during normal breathing. There were no marked differences in the RV muscle mass obtained with gradient echo imaging compared to TIR imaging in either views. Repeatability of volume analysis was better in TA than RVIT view: the mean differences were 0.7±4.0 ml and 5.4±14.0 ml in end-diastole and 1.6±3.1 ml and 1.5±13.9 ml in end-systole, respectively. Repeatability of mass analysis was good in both TIR and cine images in the RVIT view but slightly better in TIR images: 0.5±2.4 g compared to 0.8±2.9 g in cine images. Reproducibility of imaging was good, mean differences for RVEDV and RVESV were 1.0±4.8 ml and 0.8±2.8 ml

  3. Profiling the metabolic signals involved in chemical communication between microbes using imaging mass spectrometry.

    Science.gov (United States)

    Stasulli, Nikolas M; Shank, Elizabeth A

    2016-11-01

    The ability of microbes to secrete bioactive chemical signals into their environment has been known for over a century. However, it is only in the last decade that imaging mass spectrometry has provided us with the ability to directly visualize the spatial distributions of these microbial metabolites. This technology involves collecting mass spectra from multiple discrete locations across a biological sample, yielding chemical ‘maps’ that simultaneously reveal the distributions of hundreds of metabolites in two dimensions. Advances in microbial imaging mass spectrometry summarized here have included the identification of novel strain- or coculture-specific compounds, the visualization of biotransformation events (where one metabolite is converted into another by a neighboring microbe), and the implementation of a method to reconstruct the 3D subsurface distributions of metabolites, among others. Here we review the recent literature and discuss how imaging mass spectrometry has spurred novel insights regarding the chemical consequences of microbial interactions.

  4. Exploring surface photoreaction dynamics using pixel imaging mass spectrometry (PImMS)

    Science.gov (United States)

    Kershis, Matthew D.; Wilson, Daniel P.; White, Michael G.; John, Jaya John; Nomerotski, Andrei; Brouard, Mark; Lee, Jason W. L.; Vallance, Claire; Turchetta, Renato

    2013-08-01

    A new technique for studying surface photochemistry has been developed using an ion imaging time-of-flight mass spectrometer in conjunction with a fast camera capable of multimass imaging. This technique, called pixel imaging mass spectrometry (PImMS), has been applied to the study of butanone photooxidation on TiO2(110). In agreement with previous studies of this system, it was observed that the main photooxidation pathway for butanone involves ejection of an ethyl radical into vacuum which, as confirmed by our imaging experiment, undergoes fragmentation after ionization in the mass spectrometer. This proof-of-principle experiment illustrates the usefulness and applicability of PImMS technology to problems of interest within the surface science community.

  5. Proteomics with Mass Spectrometry Imaging: Beyond Amyloid Typing.

    Science.gov (United States)

    Lavatelli, Francesca; Merlini, Giampaolo

    2018-04-01

    Detection and typing of amyloid deposits in tissues are two crucial steps in the management of systemic amyloidoses. The presence of amyloid deposits is routinely evaluated through Congo red staining, whereas proteomics is now a mainstay in the identification of the deposited proteins. In article number 1700236, Winter et al. [Proteomics 2017, 17, Issue 22] describe a novel method based on MALDI-MS imaging coupled to ion mobility separation and peptide filtering, to detect the presence of amyloid in histology samples and to identify its composition, while preserving the spatial distribution of proteins in tissues. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.D. [Univ. of British Columbia, Vancouver Hospital and Helath Services Centre, Dept. of Radiology, Vancouver, British Columbia (Canada)]. E-mail: schang@vanhosp.bc.ca; Cooperberg, P.L.; Wong, A.D. [Univ. of British Columbia, St. Paul' s Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Llewellyn, P.A. [Lion' s Gate Hospital, Dept. of Radiology, North Vancouver, British Columbia (Canada); Bilbey, J.H. [Royal Inland Hospital, Dept. of Radiology, Kamloops, British Columbia (Canada)

    2004-04-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT{sub 1}-weighted localizer and a fast spin-echoT{sub 2}-weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT{sub 2}-weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  7. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    International Nuclear Information System (INIS)

    Chang, S.D.; Cooperberg, P.L.; Wong, A.D.; Llewellyn, P.A.; Bilbey, J.H.

    2004-01-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT 1 -weighted localizer and a fast spin-echoT 2 -weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT 2 -weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  8. Translational imaging mass spectrometry: From CERN to the surgeon

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    A comprehensive understanding of molecular patterns of health and disease is needed to pave the way for personalized medicine and tissue regeneration. New Mass Spectrometry based chemical microscopes that target biomedical tissue analysis in various diseases as well as other chemically complex surfaces have now firmly established themselves in translational research. In concert they elucidate the way in which local environments can influence molecular signaling pathways on various scales, from molecule to man. The integration of this pathway information in a surgical setting is imminent, but innovations that push the boundaries of the technology and its application are still needed. In particular, researchers investigate comprehensive and isolated biomolecular molecular patterns of health and disease. This is a key element needed to pave the way for personalized medicine and tissue regeneration. One barrier to predictive, personalized medicine is the lack of a comprehensive molecular understanding at the ti...

  9. Imaging of plant materials using indirect desorption electrospray ionization mass spectrometry

    DEFF Research Database (Denmark)

    Janfelt, Christian

    2015-01-01

    Indirect desorption electrospray ionization mass spectrometry (DESI-MS) imaging is a method for imaging distributions of metabolites in plant materials, in particular leaves and petals. The challenge in direct imaging of such plant materials with DESI-MS is particularly the protective layer of cu...... of interest from parts of their matrix while preserving the spatial information in the two dimensions. The imprint can then easily be imaged by DESI-MS. The method delivers simple and robust mass spectrometry imaging of plant material with very high success ratios....... of cuticular wax present in leaves and petals. The cuticle protects the plant from drying out, but also makes it difficult for the DESI sprayer to reach the analytes of interest inside the plant material. A solution to this problem is to imprint the plant material onto a surface, thus releasing the analytes...

  10. microMS: A Python Platform for Image-Guided Mass Spectrometry Profiling

    Science.gov (United States)

    Comi, Troy J.; Neumann, Elizabeth K.; Do, Thanh D.; Sweedler, Jonathan V.

    2017-09-01

    Image-guided mass spectrometry (MS) profiling provides a facile framework for analyzing samples ranging from single cells to tissue sections. The fundamental workflow utilizes a whole-slide microscopy image to select targets of interest, determine their spatial locations, and subsequently perform MS analysis at those locations. Improving upon prior reported methodology, a software package was developed for working with microscopy images. microMS, for microscopy-guided mass spectrometry, allows the user to select and profile diverse samples using a variety of target patterns and mass analyzers. Written in Python, the program provides an intuitive graphical user interface to simplify image-guided MS for novice users. The class hierarchy of instrument interactions permits integration of new MS systems while retaining the feature-rich image analysis framework. microMS is a versatile platform for performing targeted profiling experiments using a series of mass spectrometers. The flexibility in mass analyzers greatly simplifies serial analyses of the same targets by different instruments. The current capabilities of microMS are presented, and its application for off-line analysis of single cells on three distinct instruments is demonstrated. The software has been made freely available for research purposes. [Figure not available: see fulltext.

  11. Application values of 99mTc-methoxyisobutylisonitrile imaging for differentiating benign and malignant thymic masses.

    Science.gov (United States)

    Lu, Chenghui; Wang, Xufu; Liu, Bin; Liu, Xinfeng; Wang, Guoming; Zhang, Qin

    2017-08-01

    The aim of the present study was to investigate the application value of 99m Tc-methoxyisobutylisonitrile (MIBI) imaging to differentiate between benign and malignant thymic masses. A total of 32 patients with space-occupying mediastinal masses were enrolled and early and delayed-phase images were collected following injection with the imaging agent. The tumor to background ratio (T/N) values at the different phases were also recorded. The sensitivity of the qualitative analysis to distinguish between benign and malignant thymic masses was 95.24%, with specificity as 90.91%. The T/N values in the early and delayed phases were not significantly different in the group with benign thymic masses, but demonstrated statistical significant differences in the groups with low- and intermediate-grade malignant thymic masses. The T/N values at the above early and delayed phase were significantly different between the benign and low-grade malignancy groups, as well as between low- and moderate-grade malignancy groups. Those between the benign and moderate-grade malignancy groups demonstrated no significant difference. 99m Tc-MIBI imaging was able to differentiate between benign and malignant thymic masses, and the simultaneous semi-quantitative analysis of the T/N values of the tumors may be able to initially determine the degree of malignancy of thymoma.

  12. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    Science.gov (United States)

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  13. Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rompp, Andreas; Both, Jean-Pierre; Brunelle, Alain; Heeren, Ronald M.; Laprevote, Olivier; Prideaux, Brendan; Seyer, Alexandre; Spengler, Bernhard; Stoeckli, Markus; Smith, Donald F.

    2015-03-01

    Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common

  14. Diffusion-weighted MR imaging in benign and malignant orbital masses

    International Nuclear Information System (INIS)

    Guo Jian; Wang Zhenchang; Xian Junfang; Niu Yantao; Zhao Bo; Yan Fei; Liu Zhonglin; Yang Bentao

    2007-01-01

    Objective: To analyse the characteristics of orbital benign and malignant masses on diffusion weighted imaging in combination with conventional MR imaging and evaluate the diagnostic value of apparent diffusion coefficient in distinguishing benign and malignant orbital lesions. Methods: Seventy- seven cases with orbital masses, including fifty-five benign lesions and twenty-two malignant tumors, who underwent conventional MRI and diffusion imaging scanning were studied with use of a 1.5 T magnetic resonance system. Quantitative ADC measurements of masses (ADCM) and of the white matter of contralateral temporal lobe (ADC w ) were made with two different b-values of 0 and 1000 s/mm 2 . The ADC ratio (ADCR) of the lesion to the control was calculated. The receiver operating characteristic curves(ROC) were constructed using various cut points of ADCM and ADCR for different parameters to differentiate between benign and malignant masses. The area under the ROC curve for each parameter was also calculated. Results: All cases were proved by histopathology. The mean ADCM and ADCR of benign orbital masses were (1.56 ± 0.75) x 10 -3 mm 2 /s and 1.85 ± 0.91, respectively. The mean ADCM and ADCR of malignant orbital masses were (1.09 ± 0.42) x 10 -3 mm 2 /s and 1.28 ± 0.53, respectively. There were significant difference both between ADCM and ADCR of benign and malignant masses (t=2.803, 2.735, P -3 mm 2 /s for ADC M of the tumor, the sensitivity, specificity and accuracy were 59.1%, 78.2% and 72.7%, respectively. And by using cut point of 1.24 for ADCR, the sensitivity, specificity and accuracy were 59.1%, 76.4%, 71.4%, respectively. Conclusion: Diffusion MR imaging and ADC value could provide additional information for conventional magnetic resonance imaging in distinguishing benign and malignant orbital masses. (authors)

  15. Constraints of costal aquifer functioning in a deeply antropized area through a multi-isotope fingerprinting (Recife, Brazil)

    Science.gov (United States)

    Petelet-Giraud, Emmanuelle; Cary, Lise; Bertrand, Guillaume; Hirata, Ricardo; Martins, Veridiana; Montenegro, Suzana; Pauwels, Hélène; Kloppmann, Wolfram; Aquilina, Luc

    2014-05-01

    The Metropolitan Region of Recife (RMR) went through large changes of water and land uses over the last decades due to an increasing demographic pressure (1.5 M of inhabitants). These evolutions gave rise to numerous environmental consequences, such as a dramatic decline of the water levels, groundwater salinization and contamination. This degradation of natural resources is linked to the increase of water demand that is also punctually amplified by drought periods, inducing the construction of thousands of private wells. Recife city was built on an estuarine area, at the geological limits of the two sedimentary basins of Pernambuco (north of the city) and Paraíba (south of the city) separated by a famous shear zone (the Pernambuco lineament). Tectonic and sedimentary events involved in the genesis and evolution of these basins were mainly controlled by the opening of the Atlantic Ocean leading to the deposition of cretaceous sediments which now constitute the two main exploited aquifers, the Beberibe and Cabo aquifers. These two deep aquiferous formations are topped by the unconfined Boa Viagem aquifer of quaternary sediments. It is the most directly exposed to contamination, since it is connected to mangroves, rivers, estuaries and highly urbanized areas. Both the Beberibe and Cabo aquifers contain large clay levels and are separated by a rather continuous clayed formation which seems to play a consistent role of screen and to interfere in the hydraulic connections between the three aquifers. Previous isotopic studies have shown that recharge processes are similar in the aquifers, suggesting that exchanges may occur and may be modified or amplified by overexploitation. This very complex aquifer system is studied through more than 60 water samples, including some surface water samples from the main rivers. A methodology based on multi-isotopes fingerprinting is applied, including stable isotopes of the water molecule, strontium isotopes, boron isotopes, sulfur

  16. Natural products in Glycyrrhiza glabra (licorice) rhizome imaged at the cellular level by atmospheric pressure matrix-assisted laser desorption/ionization tandem mass spectrometry imaging

    DEFF Research Database (Denmark)

    Li, Bin; Bhandari, Dhaka Ram; Janfelt, Christian

    2014-01-01

    The rhizome of Glycyrrhiza glabra (licorice) was analyzed by high-resolution mass spectrometry imaging and tandem mass spectrometry imaging. An atmospheric pressure matrix-assisted laser desorption/ionization imaging ion source was combined with an orbital trapping mass spectrometer in order to o...... and saponins in legume species, combing the spatially resolved chemical information with morphological details at the microscopic level. Furthermore, the technique offers a scheme capable of high-throughput profiling of metabolites in plant tissues....

  17. Contribution of diffusion-weighted MR imaging for predicting benignity of complex adnexal masses

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Darai, Emile; Cuenod, Charles A.; Fournier, Laure; Toussaint, Irwin; Marsault, Claude; Bazot, Marc

    2009-01-01

    The purpose of this study was to prospectively assess the contribution of diffusion-weighted MR imaging (DWI) for characterizing complex adnexal masses. Seventy-seven women (22-87 years old) with complex adnexal masses (30 benign and 47 malignant) underwent MR imaging including DWI before surgery. Conventional morphological MR imaging criteria were recorded in addition to b 1,000 signal intensity and apparent diffusion coefficient (ADC) measurements of cystic and solid components. Positive likelihood ratios (PLR) were calculated for predicting benignity and malignancy. The most significant criteria for predicting benignity were low b 1,000 signal intensity within the solid component (PLR = 10.9), low T2 signal intensity within the solid component (PLR = 5.7), absence of solid portion (PLR = 3.1), absence of ascites or peritoneal implants (PLR = 2.3) and absence of papillary projections (PLR = 2.3). ADC measurements did not contribute to differentiating benign from malignant adnexal masses. All masses that displayed simultaneously low signal intensity within the solid component on T2-weighted and on b 1,000 diffusion-weighted images were benign. Alternatively, the presence of a solid component with intermediate T2 signal and high b 1,000 signal intensity was associated with a PLR of 4.5 for a malignant adnexal tumour. DWI signal intensity is an accurate tool for predicting benignity of complex adnexal masses. (orig.)

  18. Contribution of diffusion-weighted MR imaging for predicting benignity of complex adnexal masses

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique Hopitaux de Pariss, Department of Radiology, Paris (France); Universite Rene Descartes, LRI-EA4062, Paris (France); Darai, Emile [Hopital Tenon, Assistance Publique Hopitaux de Pariss, Department of Gynecology-Obstetrics, Paris (France); Cuenod, Charles A.; Fournier, Laure [Universite Rene Descartes, LRI-EA4062, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Assistance Publique Hopitaux de Paris, Department of Radiology, Paris (France); Toussaint, Irwin; Marsault, Claude; Bazot, Marc [Hopital Tenon, Assistance Publique Hopitaux de Pariss, Department of Radiology, Paris (France)

    2009-06-15

    The purpose of this study was to prospectively assess the contribution of diffusion-weighted MR imaging (DWI) for characterizing complex adnexal masses. Seventy-seven women (22-87 years old) with complex adnexal masses (30 benign and 47 malignant) underwent MR imaging including DWI before surgery. Conventional morphological MR imaging criteria were recorded in addition to b{sub 1,000} signal intensity and apparent diffusion coefficient (ADC) measurements of cystic and solid components. Positive likelihood ratios (PLR) were calculated for predicting benignity and malignancy. The most significant criteria for predicting benignity were low b{sub 1,000} signal intensity within the solid component (PLR = 10.9), low T2 signal intensity within the solid component (PLR = 5.7), absence of solid portion (PLR = 3.1), absence of ascites or peritoneal implants (PLR = 2.3) and absence of papillary projections (PLR = 2.3). ADC measurements did not contribute to differentiating benign from malignant adnexal masses. All masses that displayed simultaneously low signal intensity within the solid component on T2-weighted and on b{sub 1,000} diffusion-weighted images were benign. Alternatively, the presence of a solid component with intermediate T2 signal and high b{sub 1,000} signal intensity was associated with a PLR of 4.5 for a malignant adnexal tumour. DWI signal intensity is an accurate tool for predicting benignity of complex adnexal masses. (orig.)

  19. Early detection of breast cancer mass lesions by mammogram segmentation images based on texture features

    International Nuclear Information System (INIS)

    Mahmood, F.H.

    2012-01-01

    Mammography is at present one of the available method for early detection of masses or abnormalities which is related to breast cancer.The calcifications. The challenge lies in early and accurate detection to overcome the development of breast cancer that affects more and more women throughout the world. Breast cancer is diagnosed at advanced stages with the help of the digital mammogram images. Masses appear in a mammogram as fine, granular clusters, which are often difficult to identify in a raw mammogram. The incidence of breast cancer in women has increased significantly in recent years. This paper proposes a computer aided diagnostic system for the extraction of features like mass lesions in mammograms for early detection of breast cancer. The proposed technique is based on a four-step procedure: (a) the preprocessing of the image is done, (b) regions of interest (ROI) specification, (c) supervised segmentation method includes two to stages performed using the minimum distance (M D) criterion, and (d) feature extraction based on Gray level Co-occurrence matrices GLC M for the identification of mass lesions. The method suggested for the detection of mass lesions from mammogram image segmentation and analysis was tested over several images taken from A L-llwiya Hospital in Baghdad, Iraq.The proposed technique shows better results.

  20. Mass spectrometry imaging of biomarker lipids for phagocytosis and signalling during focal cerebral ischaemia

    DEFF Research Database (Denmark)

    Nielsen, Mette M B; Lambertsen, Kate L; Clausen, Bettina H

    2016-01-01

    biomarker CD11b, and probably with cholesteryl ester. Mass spectrometry imaging can visualize spatiotemporal changes in the lipidome during the progression and resolution of focal cerebral inflammation and suggests that BMP(22:6/22:6) and N-acyl-phosphatidylethanolamines can be used as biomarkers......Focal cerebral ischaemia has an initial phase of inflammation and tissue injury followed by a later phase of resolution and repair. Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections from mice 2 h, 24 h, 5d, 7...

  1. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review.

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites.

  2. Early detection of tumor masses by in vivo hematoporphyrin-mediated fluorescence imaging

    International Nuclear Information System (INIS)

    Autiero, Maddalena; Celentano, Luigi; Cozzolino, Rosanna; Laccetti, Paolo; Marotta, Marcello; Mettivier, Giovanni; Cristina Montesi, Maria; Quarto, Maria; Riccio, Patrizia; Roberti, Giuseppe; Russo, Paolo

    2007-01-01

    We investigated the capability of fluorescence reflectance imaging (FRI) for the early detection of surface tumors in mice. We used a hematoporphyrin (HP) compound (HP dichlorohydrate) as a red fluorescent marker and a low noise, high sensitivity, digital CCD camera for fluorescence imaging. In this preliminary study, highly malignant anaplastic human thyroid carcinoma cells were implanted subcutaneously in one mouse and their growth was monitored daily for 5 days by FRI. The selective HP uptake by the tumor tissues was successfully observed: we observed the fluorescence of tumor only 3 days after cancer cells injection, i.e. when the tumor mass was neither visible (to the naked eye) or palpable. These measurements indicate that FRI is a suitable technique to detect minute subcutaneous tumor masses. This FRI system will be coupled to a radionuclide imaging system based on a CdTe detector for in vivo multimodal imaging in mice

  3. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites. PMID:26904042

  4. Anterior mediastinal masses in the Framingham Heart Study: Prevalence and CT image characteristics

    International Nuclear Information System (INIS)

    Araki, Tetsuro; Nishino, Mizuki; Gao, Wei; Dupuis, Josée; Washko, George R.; Hunninghake, Gary M.; Murakami, Takamichi; O’Connor, George T.; Hatabu, Hiroto

    2015-01-01

    To investigate the prevalence and CT image characteristics of anterior mediastinal masses in a population-based cohort and their association with the demographics of the participants. Chest CT scans of 2571 Framingham Heart Study participants (mean age 58.9 years, 51% female) were evaluated by two board-certified radiologists with expertise in thoracic imaging for the presence of anterior mediastinal masses, their shape, contour, location, invasion of adjacent structures, fat content, and calcification. For participants with anterior mediastinal masses, a previous cardiac CT scan was reviewed for interval size change of the masses, when available. The demographics of the participants were studied for any association with the presence of anterior mediastinal masses. Of 2571, 23 participants (0.9%, 95% CI: 0.6–1.3) had anterior mediastinal masses on CT. The most common CT characteristics were oval shape, lobular contour, and midline location, showing soft tissue density (median 32.1 HU). Fat content was detected in a few cases (9%, 2/23). Six out of eight masses with available prior cardiac CT scans demonstrated an interval growth over a median period of 6.5 years. No risk factors for anterior mediastinal masses were detected among participants’ demographics, including age, sex, BMI, and cigarette smoking. The prevalence of anterior mediastinal masses is 0.9% in the Framingham Heart Study. Those masses may increase in size when observed over 5–7 years. Investigation of clinical significance in incidentally found anterior mediastinal masses with a longer period of follow-up would be necessary

  5. Digital image processing based mass flow rate measurement of gas/solid two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Song Ding; Peng Lihui; Lu Geng; Yang Shiyuan [Tsinghua National Laboratory for Information Science and Technology, Department of Automation, Tsinghua University, Beijing, 100084 (China); Yan Yong, E-mail: lihuipeng@tsinghua.edu.c [University of Kent, Canterbury, Kent CT2 7NT (United Kingdom)

    2009-02-01

    With the rapid growth of the process industry, pneumatic conveying as a tool for the transportation of a wide variety of pulverized and granular materials has become widespread. In order to improve plant control and operational efficiency, it is essential to know the parameters of the particle flow. This paper presents a digital imaging based method which is capable of measuring multiple flow parameters, including volumetric concentration, velocity and mass flow rate of particles in the gas/solid two phase flow. The measurement system consists of a solid state laser for illumination, a low-cost CCD camera for particle image acquisition and a microcomputer with bespoke software for particle image processing. The measurements of particle velocity and volumetric concentration share the same sensing hardware but use different exposure time and different image processing methods. By controlling the exposure time of the camera a clear image and a motion blurred image are obtained respectively. The clear image is thresholded by OTSU method to identify the particles from the dark background so that the volumetric concentration is determined by calculating the ratio between the particle area and the total area. Particle velocity is derived from the motion blur length, which is estimated from the motion blurred images by using the travelling wave equation method. The mass flow rate of particles is calculated by combining the particle velocity and volumetric concentration. Simulation and experiment results indicate that the proposed method is promising for the measurement of multiple parameters of gas/solid two-phase flow.

  6. Digital image processing based mass flow rate measurement of gas/solid two-phase flow

    International Nuclear Information System (INIS)

    Song Ding; Peng Lihui; Lu Geng; Yang Shiyuan; Yan Yong

    2009-01-01

    With the rapid growth of the process industry, pneumatic conveying as a tool for the transportation of a wide variety of pulverized and granular materials has become widespread. In order to improve plant control and operational efficiency, it is essential to know the parameters of the particle flow. This paper presents a digital imaging based method which is capable of measuring multiple flow parameters, including volumetric concentration, velocity and mass flow rate of particles in the gas/solid two phase flow. The measurement system consists of a solid state laser for illumination, a low-cost CCD camera for particle image acquisition and a microcomputer with bespoke software for particle image processing. The measurements of particle velocity and volumetric concentration share the same sensing hardware but use different exposure time and different image processing methods. By controlling the exposure time of the camera a clear image and a motion blurred image are obtained respectively. The clear image is thresholded by OTSU method to identify the particles from the dark background so that the volumetric concentration is determined by calculating the ratio between the particle area and the total area. Particle velocity is derived from the motion blur length, which is estimated from the motion blurred images by using the travelling wave equation method. The mass flow rate of particles is calculated by combining the particle velocity and volumetric concentration. Simulation and experiment results indicate that the proposed method is promising for the measurement of multiple parameters of gas/solid two-phase flow.

  7. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  8. IMAGE-PLANE ANALYSIS OF n-POINT-MASS LENS CRITICAL CURVES AND CAUSTICS

    Energy Technology Data Exchange (ETDEWEB)

    Danek, Kamil; Heyrovský, David, E-mail: kamil.danek@utf.mff.cuni.cz, E-mail: heyrovsky@utf.mff.cuni.cz [Institute of Theoretical Physics, Faculty of Mathematics and Physics, Charles University in Prague (Czech Republic)

    2015-06-10

    The interpretation of gravitational microlensing events caused by planetary systems or multiple stars is based on the n-point-mass lens model. The first planets detected by microlensing were well described by the two-point-mass model of a star with one planet. By the end of 2014, four events involving three-point-mass lenses had been announced. Two of the lenses were stars with two planetary companions each; two were binary stars with a planet orbiting one component. While the two-point-mass model is well understood, the same cannot be said for lenses with three or more components. Even the range of possible critical-curve topologies and caustic geometries of the three-point-mass lens remains unknown. In this paper we provide new tools for mapping the critical-curve topology and caustic cusp number in the parameter space of n-point-mass lenses. We perform our analysis in the image plane of the lens. We show that all contours of the Jacobian are critical curves of re-scaled versions of the lens configuration. Utilizing this property further, we introduce the cusp curve to identify cusp-image positions on all contours simultaneously. In order to track cusp-number changes in caustic metamorphoses, we define the morph curve, which pinpoints the positions of metamorphosis-point images along the cusp curve. We demonstrate the usage of both curves on simple two- and three-point-mass lens examples. For the three simplest caustic metamorphoses we illustrate the local structure of the image and source planes.

  9. Imaging diagnosis of accessory and cavitated uterine mass, a rare mullerian anomaly

    Directory of Open Access Journals (Sweden)

    Nishchint Jain

    2014-01-01

    Full Text Available Accessory and Cavitated Uterine Mass (ACUM is a rare form of developmental Mullerian anomaly seen in young females, which presents as chronic recurrent pelvic pain and severe dysmenorrhea. It is an accessory cavity lying within an otherwise normal uterus. It is lined by functional endometrium and surrounded by myometrium-like smooth muscle cells; hence, it bears striking macroscopic and microscopic resemblance to the uterus. Hysterosalpingography (HSG, Ultrasonography (USG, and Magnetic Resonance Imaging (MRI form the mainstay of diagnostic imaging. The entity is often under diagnosed; therefore, a high index of suspicion combined with HSG and MRI imaging can help in making an accurate diagnosis.

  10. Imaging diagnosis of accessory and cavitated uterine mass, a rare mullerian anomaly

    International Nuclear Information System (INIS)

    Jain, Nishchint; Verma, Ritu

    2014-01-01

    Accessory and Cavitated Uterine Mass (ACUM) is a rare form of developmental Mullerian anomaly seen in young females, which presents as chronic recurrent pelvic pain and severe dysmenorrhea. It is an accessory cavity lying within an otherwise normal uterus. It is lined by functional endometrium and surrounded by myometrium-like smooth muscle cells; hence, it bears striking macroscopic and microscopic resemblance to the uterus. Hysterosalpingography (HSG), Ultrasonography (USG), and Magnetic Resonance Imaging (MRI) form the mainstay of diagnostic imaging. The entity is often under diagnosed; therefore, a high index of suspicion combined with HSG and MRI imaging can help in making an accurate diagnosis

  11. Combined X-ray CT and mass spectrometry for biomedical imaging applications

    Science.gov (United States)

    Schioppa, E., Jr.; Ellis, S.; Bruinen, A. L.; Visser, J.; Heeren, R. M. A.; Uher, J.; Koffeman, E.

    2014-04-01

    Imaging technologies play a key role in many branches of science, especially in biology and medicine. They provide an invaluable insight into both internal structure and processes within a broad range of samples. There are many techniques that allow one to obtain images of an object. Different techniques are based on the analysis of a particular sample property by means of a dedicated imaging system, and as such, each imaging modality provides the researcher with different information. The use of multimodal imaging (imaging with several different techniques) can provide additional and complementary information that is not possible when employing a single imaging technique alone. In this study, we present for the first time a multi-modal imaging technique where X-ray computerized tomography (CT) is combined with mass spectrometry imaging (MSI). While X-ray CT provides 3-dimensional information regarding the internal structure of the sample based on X-ray absorption coefficients, MSI of thin sections acquired from the same sample allows the spatial distribution of many elements/molecules, each distinguished by its unique mass-to-charge ratio (m/z), to be determined within a single measurement and with a spatial resolution as low as 1 μm or even less. The aim of the work is to demonstrate how molecular information from MSI can be spatially correlated with 3D structural information acquired from X-ray CT. In these experiments, frozen samples are imaged in an X-ray CT setup using Medipix based detectors equipped with a CO2 cooled sample holder. Single projections are pre-processed before tomographic reconstruction using a signal-to-thickness calibration. In the second step, the object is sliced into thin sections (circa 20 μm) that are then imaged using both matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and secondary ion (SIMS) mass spectrometry, where the spatial distribution of specific molecules within the sample is determined. The

  12. On the Importance of Mathematical Methods for Analysis of MALDI-Imaging Mass Spectrometry Data

    Directory of Open Access Journals (Sweden)

    Trede Dennis

    2012-03-01

    Full Text Available In the last decade, matrix-assisted laser desorption/ionization (MALDI imaging mass spectrometry (IMS, also called as MALDI-imaging, has proven its potential in proteomics and was successfully applied to various types of biomedical problems, in particular to histopathological label-free analysis of tissue sections. In histopathology, MALDI-imaging is used as a general analytic tool revealing the functional proteomic structure of tissue sections, and as a discovery tool for detecting new biomarkers discriminating a region annotated by an experienced histologist, in particular, for cancer studies.

  13. The Children's Body Image Scale: reliability and use with international standards for body mass index.

    Science.gov (United States)

    Truby, Helen; Paxton, Susan J

    2008-03-01

    To test the reliability of the Children's Body Image Scale (CBIS) and assess its usefulness in the context of new body size charts for children. Participants were 281 primary schoolchildren with 50% being retested after 3 weeks. The CBIS figure scale was compared with a range of international body mass index (BMI) reference standards. Children had a high degree of body image dissatisfaction. The test-retest reliability of the CBIS was supported. The CBIS is a useful tool for assessing body image in children with sound scale properties. It can also be used to identify the body size of children, which lies outside the healthy weight range of BMI.

  14. New Ionization and Detection Technologies for Mass Spectrometry Imaging. From Small Molecules to Intact Proteins

    NARCIS (Netherlands)

    Kiss, A.

    2014-01-01

    There is a constantly growing interest in biomedical research to visualize changes in the location of various biomolecules in tissue sections as a result of complex diseases. Mass spectrometry imaging is one of the techniques that enable the mapping of molecules on a 2D surface. However, the

  15. Tissue imaging with a stigmatic mass microscope using laser desorption/ionization

    Science.gov (United States)

    Awazu, Kunio; Hazama, Hisanao; Hamanaka, Tomonori; Aoki, Jun; Toyoda, Michisato; Naito, Yasuhide

    2012-03-01

    A novel stigmatic mass microscope using laser desorption/ionization and a multi-turn time-of-flight mass spectrometer, MULTUM-IMG, has been developed. Stigmatic ion images of crystal violet masked by a fine square mesh grid with a 12.7 μm pitch were clearly observed, and the estimated spatial resolution was about 3 μm in the linear mode with a 20-fold ion optical magnification. Tissue sections of a brain and eyes of a mouse stained with crystal violet and methylene blue were observed in the linear mode, and the stigmatic total ion images of crystal violet and methylene blue agreed well with the optical photomicrograph of the same sections. Especially, the fine structure in the cornea tissue was clearly observed with a spatial resolution in the range of micrometers. Although the total measurement time of the stigmatic ion image for the whole-eye section was about 59 minutes using a laser with a 10 Hz repetition rate, the measurement time could be reduced to about 35 s using a laser with a 1 kHz repetition rate and automation of measurements. The stigmatic mass microscope developed in this research should be suitable for high-spatial resolution and high-throughput imaging mass spectrometry for pathology, pharmacokinetics, and so on.

  16. Magnetic resonance imaging of flow and mass transfer in electrohydrodynamic liquid bridges

    NARCIS (Netherlands)

    Wexler, Adam D.; Drusová, Sandra; Fuchs, Elmar C.; Woisetschläger, Jakob; Reiter, Gert; Fuchsjäger, Michael; Reiter, Ursula

    2017-01-01

    Abstract: Here, we report on the feasibility and use of magnetic resonance imaging-based methods to the study of electrohydrodynamic (EHD) liquid bridges. High-speed tomographic recordings through the longitudinal axis of water bridges were used to characterize the mass transfer dynamics, mixing,

  17. Matrix-assisted laser desorption/ionisation mass spectrometry imaging and its development for plant protein imaging

    Directory of Open Access Journals (Sweden)

    Millar A Harvey

    2011-07-01

    Full Text Available Abstract Matrix-Assisted Laser Desorption/Ionisation (MALDI mass spectrometry imaging (MSI uses the power of high mass resolution time of flight (ToF mass spectrometry coupled to the raster of lasers shots across the cut surface of tissues to provide new insights into the spatial distribution of biomolecules within biological tissues. The history of this technique in animals and plants is considered and the potential for analysis of proteins by this technique in plants is discussed. Protein biomarker identification from MALDI-MSI is a challenge and a number of different approaches to address this bottleneck are discussed. The technical considerations needed for MALDI-MSI are reviewed and these are presented alongside examples from our own work and a protocol for MALDI-MSI of proteins in plant samples.

  18. Classification of breast masses by ultrasonic Nakagami imaging: a feasibility study

    Science.gov (United States)

    Tsui, Po-Hsiang; Yeh, Chih-Kuang; Chang, Chien-Cheng; Liao, Yin-Yin

    2008-11-01

    Ultrasound is an important clinical tool in noninvasive diagnoses of breast cancer. The Nakagami statistical parameter estimated from the ultrasonic backscattered envelope has been demonstrated to be useful in complementing conventional B-mode scans when classifying breast masses. However, the shadowing effect caused by certain high-attenuation tumors in the B-mode image makes the tumor contour unclear, and thus it is more difficult to choose an appropriate region of interest from which to collect tumor data for estimating the Nakagami parameter. This study explored the feasibility of using the Nakagami parametric image to overcome the shadowing effect for visualizing the properties of breast masses. Experiments were performed on a breast-mimicking phantom and on some typical clinical cases for cysts, fat and tumors (fibroadenoma) (n = 18) in order to explore the performance of the Nakagami image under ideal and practical conditions. The experimental results showed that the Nakagami image pixels (i.e. the local Nakagami parameter) in the cyst, tumor and fat are 0.21 ± 0.01, 0.65 ± 0.05 and 0.98 ± 0.07, respectively, for six independent phantom measurements, and 0.14 ± 0.03, 0.67 ± 0.11 and 0.89 ± 0.08, respectively, for clinical experiments. This suggests that the Nakagami image is able to classify various breast masses (p < 0.005) although the clinical results from tumors of different cases have a larger variance that may be caused by the complexity of real breast tissues. In particular, unlike the B-mode image, the Nakagami image is not subject to significant shadowing effects, making it useful to complement the B-mode image to describe the tumor contour for identifying the tumor-related region when the shadowing effect is stronger or a low system gain is used.

  19. Classification of breast masses by ultrasonic Nakagami imaging: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tsui, P-H; Chang, C-C [Division of Mechanics, Research Center for Applied Sciences, Academia Sinica, 128, Section 2, Academia Road, Nankang, Taipei 11529, Taiwan (China); Yeh, C-K; Liao, Y-Y [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China)], E-mail: mechang@gate.sinica.edu.tw, E-mail: ckyeh@mx.nthu.edu.tw

    2008-11-07

    Ultrasound is an important clinical tool in noninvasive diagnoses of breast cancer. The Nakagami statistical parameter estimated from the ultrasonic backscattered envelope has been demonstrated to be useful in complementing conventional B-mode scans when classifying breast masses. However, the shadowing effect caused by certain high-attenuation tumors in the B-mode image makes the tumor contour unclear, and thus it is more difficult to choose an appropriate region of interest from which to collect tumor data for estimating the Nakagami parameter. This study explored the feasibility of using the Nakagami parametric image to overcome the shadowing effect for visualizing the properties of breast masses. Experiments were performed on a breast-mimicking phantom and on some typical clinical cases for cysts, fat and tumors (fibroadenoma) (n = 18) in order to explore the performance of the Nakagami image under ideal and practical conditions. The experimental results showed that the Nakagami image pixels (i.e. the local Nakagami parameter) in the cyst, tumor and fat are 0.21 {+-} 0.01, 0.65 {+-} 0.05 and 0.98 {+-} 0.07, respectively, for six independent phantom measurements, and 0.14 {+-} 0.03, 0.67 {+-} 0.11 and 0.89 {+-} 0.08, respectively, for clinical experiments. This suggests that the Nakagami image is able to classify various breast masses (p < 0.005) although the clinical results from tumors of different cases have a larger variance that may be caused by the complexity of real breast tissues. In particular, unlike the B-mode image, the Nakagami image is not subject to significant shadowing effects, making it useful to complement the B-mode image to describe the tumor contour for identifying the tumor-related region when the shadowing effect is stronger or a low system gain is used.

  20. Observation of endoplasmic reticulum tubules via TOF-SIMS tandem mass spectrometry imaging of transfected cells.

    Science.gov (United States)

    Chini, Corryn E; Fisher, Gregory L; Johnson, Ben; Tamkun, Michael M; Kraft, Mary L

    2018-02-26

    Advances in three-dimensional secondary ion mass spectrometry (SIMS) imaging have enabled visualizing the subcellular distributions of various lipid species within individual cells. However, the difficulty of locating organelles using SIMS limits efforts to study their lipid compositions. Here, the authors have assessed whether endoplasmic reticulum (ER)-Tracker Blue White DPX ® , which is a commercially available stain for visualizing the endoplasmic reticulum using fluorescence microscopy, produces distinctive ions that can be used to locate the endoplasmic reticulum using SIMS. Time-of-flight-SIMS tandem mass spectrometry (MS 2 ) imaging was used to identify positively and negatively charged ions produced by the ER-Tracker stain. Then, these ions were used to localize the stain and thus the endoplasmic reticulum, within individual human embryonic kidney cells that contained higher numbers of endoplasmic reticulum-plasma membrane junctions on their surfaces. By performing MS 2 imaging of selected ions in parallel with the precursor ion (MS 1 ) imaging, the authors detected a chemical interference native to the cell at the same nominal mass as the pentafluorophenyl fragment from the ER-Tracker stain. Nonetheless, the fluorine secondary ions produced by the ER-Tracker stain provided a distinctive signal that enabled locating the endoplasmic reticulum using SIMS. This simple strategy for visualizing the endoplasmic reticulum in individual cells using SIMS could be combined with existing SIMS methodologies for imaging intracellular lipid distribution and to study the lipid composition within the endoplasmic reticulum.

  1. Imaging Findings of an Unusually Located Hydatid Cyst Presented as a Sacrococcygeal Mass

    International Nuclear Information System (INIS)

    Yilmaz, Guliz; Halil Akpinar, Suha

    2015-01-01

    Hydatid disease (HD) is a parasitic infection that is most commonly caused by the larval stage of Echinococcus granulosus. Unusual location for this disease can cause diagnostic and therapeutic problems. We herein report a case of sacrococcygeal HD at an unusual location in a 30-year-old woman. She was evaluated using computed tomography (CT) imaging and magnetic resonance imaging (MRI) after the demonstration of the lucent bone lesion on plain pelvic radiography. There was an expansile lytic mass without contrast enhancement suggesting a cystic mass in the sacrococcygeal region. Medical history revealed that she had undergone surgery for liver HD and the serological test results were diagnostic for HD. In light of this, no surgery was carried out for this cystic mass and she was followed with the diagnosis of sacrococcygeal HD

  2. Imaging in the diagnosis of a patient with an intra-abdominal mass

    International Nuclear Information System (INIS)

    Funston, M.R.

    1985-01-01

    There have been rapid and significant developments in the imaging techniques available to the radiologist during the last decade. The clinician investigating an abdominal mass is often baffled by what examinations to request and in what sequence. An attempt is made to simplify this complex problem by outlining the broad principles of the imaging approach. The development of and advances in ultrasonography and CT, both non-invasive techniques, have had a major impact on the pre-operative diagnosis of abdominal masses. Both examinations are rapidly performed and eliminate the wasted man-hours and preparation requested for barium and other contrast-medium examinations. Other techniques discussed are visceral angiography radioisotope scanning and percutaneous fine-needle biopsies. A teamwork approach is advocated because it eliminates unnecessary and costly studies and results in a diagnosis being made with a minimum of hazard, cost and inconvenience to the patient. The author also presents a table of the more common abdominal masses

  3. Targeted Multiplex Imaging Mass Spectrometry with Single Chain Fragment Variable (scfv) Recombinant Antibodies

    Science.gov (United States)

    Thiery, Gwendoline; Mernaugh, Ray L.; Yan, Heping; Spraggins, Jeffrey M.; Yang, Junhai; Parl, Fritz F.; Caprioli, Richard M.

    2012-10-01

    Recombinant scfv antibodies specific for CYP1A1 and CYP1B1 P450 enzymes were combined with targeted imaging mass spectrometry to simultaneously detect the P450 enzymes present in archived, paraffin-embedded, human breast cancer tissue sections. By using CYP1A1 and CYP1B1 specific scfv, each coupled to a unique reporter molecule (i.e., a mass tag) it was possible to simultaneously detect multiple antigens within a single tissue sample with high sensitivity and specificity using mass spectrometry. The capability of imaging multiple antigens at the same time is a significant advance that overcomes technical barriers encountered when using present day approaches to develop assays that can simultaneously detect more than a single antigen in the same tissue sample.

  4. Metabolomic imaging of prostate cancer with magnetic resonance spectroscopy and mass spectrometry

    International Nuclear Information System (INIS)

    Spur, Eva-Margarete; Decelle, Emily A.; Cheng, Leo L.

    2013-01-01

    Metabolomic imaging of prostate cancer (PCa) aims to improve in vivo imaging capability so that PCa tumors can be localized noninvasively to guide biopsy and evaluated for aggressiveness prior to prostatectomy, as well as to assess and monitor PCa growth in patients with asymptomatic PCa newly diagnosed by biopsy. Metabolomics studies global variations of metabolites with which malignancy conditions can be evaluated by profiling the entire measurable metabolome, instead of focusing only on certain metabolites or isolated metabolic pathways. At present, PCa metabolomics is mainly studied by magnetic resonance spectroscopy (MRS) and mass spectrometry (MS). With MRS imaging, the anatomic image, obtained from magnetic resonance imaging, is mapped with values of disease condition-specific metabolomic profiles calculated from MRS of each location. For example, imaging of removed whole prostates has demonstrated the ability of metabolomic profiles to differentiate cancerous foci from histologically benign regions. Additionally, MS metabolomic imaging of prostate biopsies has uncovered metabolomic expression patterns that could discriminate between PCa and benign tissue. Metabolomic imaging offers the potential to identify cancer lesions to guide prostate biopsy and evaluate PCa aggressiveness noninvasively in vivo, or ex vivo to increase the power of pathology analysis. Potentially, this imaging ability could be applied not only to PCa, but also to different tissues and organs to evaluate other human malignancies and metabolic diseases. (orig.)

  5. Metabolomic imaging of prostate cancer with magnetic resonance spectroscopy and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Spur, Eva-Margarete [Massachusetts General Hospital, Harvard Medical School, Department of Pathology, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Charite Universitaetsmedizin, Berlin (Germany); Decelle, Emily A.; Cheng, Leo L. [Massachusetts General Hospital, Harvard Medical School, Department of Pathology, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2013-07-15

    Metabolomic imaging of prostate cancer (PCa) aims to improve in vivo imaging capability so that PCa tumors can be localized noninvasively to guide biopsy and evaluated for aggressiveness prior to prostatectomy, as well as to assess and monitor PCa growth in patients with asymptomatic PCa newly diagnosed by biopsy. Metabolomics studies global variations of metabolites with which malignancy conditions can be evaluated by profiling the entire measurable metabolome, instead of focusing only on certain metabolites or isolated metabolic pathways. At present, PCa metabolomics is mainly studied by magnetic resonance spectroscopy (MRS) and mass spectrometry (MS). With MRS imaging, the anatomic image, obtained from magnetic resonance imaging, is mapped with values of disease condition-specific metabolomic profiles calculated from MRS of each location. For example, imaging of removed whole prostates has demonstrated the ability of metabolomic profiles to differentiate cancerous foci from histologically benign regions. Additionally, MS metabolomic imaging of prostate biopsies has uncovered metabolomic expression patterns that could discriminate between PCa and benign tissue. Metabolomic imaging offers the potential to identify cancer lesions to guide prostate biopsy and evaluate PCa aggressiveness noninvasively in vivo, or ex vivo to increase the power of pathology analysis. Potentially, this imaging ability could be applied not only to PCa, but also to different tissues and organs to evaluate other human malignancies and metabolic diseases. (orig.)

  6. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging.

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed. Graphical Abstract ᅟ.

  7. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed.

  8. Multi-isotope (carbon and chlorine) analysis for fingerprinting and site characterization at a fractured bedrock aquifer contaminated by chlorinated ethenes

    International Nuclear Information System (INIS)

    Palau, Jordi; Marchesi, Massimo; Chambon, Julie C.C.; Aravena, Ramon; Canals, Àngels; Binning, Philip J.; Bjerg, Poul L.; Otero, Neus; Soler, Albert

    2014-01-01

    The use of compound specific multi-isotope approach (C and Cl) in the characterization of a chlorinated ethenes contaminated fractured aquifer allows the identification of several sources and contaminant plumes, as well as the occurrence of biodegradation and mixing processes. The study site is located in Spain with contamination resulting in groundwater concentrations of up to 50 mg/L of trichloroethene (TCE), the most abundant chlorinated ethene, and 7 mg/L of tetrachloroethene (PCE). The potential sources of contamination including abandoned barrels, an underground tank, and a disposal lagoon, showed a wide range in δ 13 C values from − 15.6 to − 40.5‰ for TCE and from − 18.5 to − 32.4‰ for PCE, allowing the use of isotope fingerprinting for tracing of the origin and migration of these contaminants in the aquifer. In contrast, there is no difference between the δ 37 Cl values for TCE in the contaminant sources, ranging from + 0.53 to + 0.66‰. Variations of δ 37 Cl and δ 13 C in the different contaminant plumes were used to investigate the role of biodegradation in groundwater. Moreover, the isotopic data were incorporated into a reactive transport model for determination of whether the isotope pattern observed downstream from the tank's source could be explained by the simultaneous effect of mixing and biodegradation. The results demonstrate that a multi-isotope approach is a valuable tool for characterization of complex sites such as fractured bedrock aquifer contaminated by multiple sources, providing important information which can be used by consultants and site managers to prioritize and design more successful remediation strategies. - Highlights: • Origin and fate of CAHs in groundwater by means of multi CSIA ( 13 C, 35 Cl) survey • Innovative/new approach tested in a fractured bedrock site • Differentiation of distinct CAH sources • Biodegradation and source mixing recognition in the aquifer

  9. Water-rock-tailings interactions and sources of sulfur and metals in the subtropical mining region of Taxco, Guerrero (southern Mexico): A multi-isotopic approach

    International Nuclear Information System (INIS)

    Talavera Mendoza, Oscar; Ruiz, Joaquin; Díaz Villaseñor, Elvia; Ramírez Guzmán, Alejandro; Cortés, Alejandra; Salgado Souto, Sergio Adrián; Dótor Almazán, Azucena; Rivera Bustos, Reymundo

    2016-01-01

    Multi-isotope (H, O, S, Sr, Pb) systems coupled with conventional (major and trace element) hydrogeochemical analysis were applied to determine the origin of water, to model water-rock-tailings interactions and for source apportionment of sulfur and associated toxic metals in the mining region of Taxco, Guerrero in southern Mexico. Oxygen and H isotopes indicate that meteoric water in the zone is rainwater undergoing varying degrees of isotopic fractionation by atmospheric evaporation whereas Sr isotopes trace the interaction of pristine water from volcanics of the regional recharge zone and subsequently flowing through sandstone and shale to spring points. Leachates form from two distinctive sources (spring water and surface water) having differential interactions with bedrocks prior to entering the tailings. Compared to pristine water, leachates are enriched in sulfate, metals (e.g. Fe, Mn, Pb and Zn) and metalloids (e.g. As). The sulfur isotopic composition of ore-sulfides, leachates, secondary precipitates, regional surface water and hypogenic sulfates is described in terms of a two-component mixing model with shale of Mexcala and limestone of Morelos formations representing the light and heavy end-members, respectively, whereas Sr isotopic composition is bracketed combining three lithogenic (Mexcala/Morelos, Tilzapotla and Taxco Schist) sources. Finally, leachates have a mixture of lead from ore-sulfides and Taxco Schist Formation (Family I) or from ore-sulfides alone (Family II). The application of multiple environmental isotopic techniques is an outstanding tool for elucidating complex interactions of water with bedrocks and tailings and for determining the source of sulfur and toxic metal from mining and other metal polluted environments. - Highlights: • We applied multi-isotope techniques to model water-bedrocks-tailings interaction. • Spring water records fractionation by evaporation and interaction with local rocks. • The sulfur cycle is modeled in

  10. Building materials as intrinsic sources of sulphate: A hidden face of salt weathering of historical monuments investigated through multi-isotope tracing (B, O, S)

    International Nuclear Information System (INIS)

    Kloppmann, W.; Bromblet, P.; Vallet, J.M.; Verges-Belmin, V.; Rolland, O.; Guerrot, C.; Gosselin, C.

    2011-01-01

    Sulphate neoformation is a major factor of degradation of stone monuments. Boron, sulphur and oxygen isotope signatures were investigated for five French historical monuments (Bourges, Chartres and Marseille cathedrals, Chenonceau castle, and Versailles garden statues) to investigate the role of intrinsic sulphate sources (gypsum plasters and mortars) in stone degradation, compared to the influence of extrinsic sources such as atmospheric pollution. Gypsum plasters and gypsum-containing mortars fall systematically in the δ 34 S and δ 18 O range of Paris Basin Eocene evaporites indicating the origin of the raw materials (so-called 'Paris plaster'). Black crusts show the typical S and O isotope signatures observed elsewhere in Europe that can be attributed to atmospheric pollution, together with a marine component for Marseille. Boron isotopes for black crusts indicate coal combustion as principal boron source. Mortar isotope compositions discriminate three types, one similar to gypsum plasters, one strongly depleted in 34 S, attributed to pyrite oxidation, and a third one close to atmospheric sulphates. The isotopic composition of sulphates and boron of most degraded building stones of the different monuments is well explained by the identified sulphate sources. In several cases (in particular for Chenonceau and Bourges, to some extent for Chartres), the impact of gypsum plaster as building and restoration material on the degradation of the stones in its vicinity was clearly demonstrated. The study illustrates the usefulness of multi-isotope studies to investigate stone degradation factors, as the combination of several isotope systematics increases the discriminatory power of isotope studies with respect to contaminant sources. - Research Highlights: → Insight in stone weathering mechanisms by multi-isotope fingerprinting (B, S, O). → Intrinsic sulphate sources (gypsum plaster, mortar) contribute to stone degradation. → Origin of building materials

  11. Building materials as intrinsic sources of sulphate: A hidden face of salt weathering of historical monuments investigated through multi-isotope tracing (B, O, S)

    Energy Technology Data Exchange (ETDEWEB)

    Kloppmann, W., E-mail: w.kloppmann@brgm.fr [BRGM, BP 6009, F-45060 Orleans cedex 2 (France); Bromblet, P.; Vallet, J.M. [CICRP, 21, rue Guibal, F-13003 Marseille (France); Verges-Belmin, V. [LRMH, 29, rue de Paris, F-77420 Champs sur Marne (France); Rolland, O. [Independent restorer, 3, rue du Gue, 37270 Montlouis s/Loire (France); Guerrot, C. [BRGM, BP 6009, F-45060 Orleans cedex 2 (France); Gosselin, C. [BRGM, BP 6009, F-45060 Orleans cedex 2 (France); LRMH, 29, rue de Paris, F-77420 Champs sur Marne (France)

    2011-04-01

    Sulphate neoformation is a major factor of degradation of stone monuments. Boron, sulphur and oxygen isotope signatures were investigated for five French historical monuments (Bourges, Chartres and Marseille cathedrals, Chenonceau castle, and Versailles garden statues) to investigate the role of intrinsic sulphate sources (gypsum plasters and mortars) in stone degradation, compared to the influence of extrinsic sources such as atmospheric pollution. Gypsum plasters and gypsum-containing mortars fall systematically in the {delta}{sup 34}S and {delta}{sup 18}O range of Paris Basin Eocene evaporites indicating the origin of the raw materials (so-called 'Paris plaster'). Black crusts show the typical S and O isotope signatures observed elsewhere in Europe that can be attributed to atmospheric pollution, together with a marine component for Marseille. Boron isotopes for black crusts indicate coal combustion as principal boron source. Mortar isotope compositions discriminate three types, one similar to gypsum plasters, one strongly depleted in {sup 34}S, attributed to pyrite oxidation, and a third one close to atmospheric sulphates. The isotopic composition of sulphates and boron of most degraded building stones of the different monuments is well explained by the identified sulphate sources. In several cases (in particular for Chenonceau and Bourges, to some extent for Chartres), the impact of gypsum plaster as building and restoration material on the degradation of the stones in its vicinity was clearly demonstrated. The study illustrates the usefulness of multi-isotope studies to investigate stone degradation factors, as the combination of several isotope systematics increases the discriminatory power of isotope studies with respect to contaminant sources. - Research Highlights: {yields} Insight in stone weathering mechanisms by multi-isotope fingerprinting (B, S, O). {yields} Intrinsic sulphate sources (gypsum plaster, mortar) contribute to stone degradation

  12. The role of magnetic resonance imaging and ultrasound in patients with adnexal masses.

    Science.gov (United States)

    Sohaib, S A; Mills, T D; Sahdev, A; Webb, J A W; Vantrappen, P O; Jacobs, I J; Reznek, R H

    2005-03-01

    To evaluate the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) in characterizing adnexal masses, and to determine which patients may benefit from MRI. We prospectively studied 72 women (mean age 53 years, range 19 to 86 years) with clinically suspected adnexal masses. A single experienced sonographer performed transabdominal and transvaginal greyscale spectral and colour Doppler examinations. MRI was carried out on a 1.5T system using T1, T2 and fat-suppressed T1-weighted sequences before and after intravenous injection of gadolinium. The adnexal masses were categorized as benign or malignant without knowledge of clinical details, according to the imaging features which were compared with the surgical and pathological findings. For characterizing lesions as malignant, the sensitivity, specificity and accuracy of MRI were 96.6%, 83.7% and 88.9%, respectively, and of US were 100%, 39.5% and 63.9%, respectively. MRI was more specific (pbenign and 28 (39%) cases with malignant masses. MRI correctly diagnosed 19 (26%) cases with benign lesion(s), which on US were thought to be malignant. The age, menopausal status and CA-125 levels in these women made benign disease likely, but US features were suggestive of malignancy (large masses and solid-cystic lesions with nodules). MRI is more specific and accurate than US and Doppler assessment for characterizing adnexal masses. Women who clinically have a relatively low risk of malignancy but who have complex sonographic features may benefit from MRI.

  13. Automatic registration of imaging mass spectrometry data to the Allen Brain Atlas transcriptome

    Science.gov (United States)

    Abdelmoula, Walid M.; Carreira, Ricardo J.; Shyti, Reinald; Balluff, Benjamin; Tolner, Else; van den Maagdenberg, Arn M. J. M.; Lelieveldt, B. P. F.; McDonnell, Liam; Dijkstra, Jouke

    2014-03-01

    Imaging Mass Spectrometry (IMS) is an emerging molecular imaging technology that provides spatially resolved information on biomolecular structures; each image pixel effectively represents a molecular mass spectrum. By combining the histological images and IMS-images, neuroanatomical structures can be distinguished based on their biomolecular features as opposed to morphological features. The combination of IMS data with spatially resolved gene expression maps of the mouse brain, as provided by the Allen Mouse Brain atlas, would enable comparative studies of spatial metabolic and gene expression patterns in life-sciences research and biomarker discovery. As such, it would be highly desirable to spatially register IMS slices to the Allen Brain Atlas (ABA). In this paper, we propose a multi-step automatic registration pipeline to register ABA histology to IMS- images. Key novelty of the method is the selection of the best reference section from the ABA, based on pre-processed histology sections. First, we extracted a hippocampus-specific geometrical feature from the given experimental histological section to initially localize it among the ABA sections. Then, feature-based linear registration is applied to the initially localized section and its two neighbors in the ABA to select the most similar reference section. A non-rigid registration yields a one-to-one mapping of the experimental IMS slice to the ABA. The pipeline was applied on 6 coronal sections from two mouse brains, showing high anatomical correspondence, demonstrating the feasibility of complementing biomolecule distributions from individual mice with the genome-wide ABA transcriptome.

  14. Value of 18F-FDG PET imaging for differentiation of benign and malignant pancreatic mass

    International Nuclear Information System (INIS)

    Zhang Liying; Guo Wanhua; Guan Liang; Li Peiyong

    2002-01-01

    To evaluate the value of positron emission tomography (PET) imaging with 18 F-FDG in differentiation of benign and malignant pancreatic mass. 12 patients with pancreatic occupying lesion diagnosed by ultrasound or CT/MR including 7 pancreatic cancer and 5 pancreatitis underwent 18 F-FDG PET imaging. Visual interpretation and semiquantitative analysis by calculating the tumor/liver (T/L) ratio based on ROI were performed on attenuation corrected images. 9 positive findings were detected. Among them, 7 were confirmed to be cancer, but the other 2 were mass-forming pancreatitis. Final diagnoses of the 3 patients with negative findings were confirmed to be pancreatitis. The mean T/L ratio was 2.58 +- 0.95 in pancreatic cancer, significantly higher than that in pancreatitis (1.29 +- 0.87) (p = 0.037). With a T/L ratio cutoff value of 1.5, all 7 cancer patients were correctly categorized. However, one pancreatitis had T/L ratio higher than 1.5. 18 F-FEG PET imaging was a potential reliable method in differentiating benign or malignant pancreatic mass with high negative predictive value, but the specificity was limited. Semiquantitative analysis may improve the accuracy of the diagnosis

  15. Hubble Space Telescope Imaging of the Mass-losing Supergiant VY Canis Majoris

    Science.gov (United States)

    Kastner, Joel H.; Weintraub, David A.

    1998-04-01

    The highly luminous M supergiant VY CMa is a massive star that appears to be in its final death throes, losing mass at high rate en route to exploding as a supernova. Subarcsecond-resolution optical images of VY CMa, obtained with the Faint Object Camera (FOC) aboard the Hubble Space Telescope, vividly demonstrate that mass loss from VY CMa is highly anisotropic. In the FOC images, the optical ``star'' VY CMa constitutes the bright, well-resolved core of an elongated reflection nebula. The imaged nebula is ~3" (~4500 AU) in extent and is clumpy and highly asymmetric. The images indicate that the bright core, which lies near one edge of the nebula, is pure scattered starlight. We conclude that at optical wavelengths VY CMa is obscured from view along our line of sight by its own dusty envelope. The presence of the extended reflection nebula then suggests that this envelope is highly flattened and/or that the star is surrounded by a massive circumstellar disk. Such axisymmetric circumstellar density structure should have profound effects on post-red supergiant mass loss from VY CMa and, ultimately, on the shaping of the remnant of the supernova that will terminate its post-main-sequence evolution.

  16. Body Image, Food Addiction, Depression, and Body Mass Index in University Students.

    Science.gov (United States)

    Şanlier, Nevin; Türközü, Duygu; Toka, Onur

    2016-01-01

    The relationship between body image, depression, food addiction and body mass index (BMI) and differences in these variables due to gender and field of education have not been studied extensively. This study was conducted on a total of 793 university students (20.19 ± 1.90 years). The Beck Depression Inventory, Yale Food Addiction, and Body Image Scale were used. It was determined that body image scores of females and individuals enrolled in health sciences programs were lower compared to those of males and those enrolled in the social sciences. There was a negative relationship between body image and depression and food addiction scores. There was a positive relationship between food addiction and depression scores, in addition to a positive relationship between food addiction and BMI.

  17. The Sheath Transport Observer for the Redistribution of Mass (STORM) Image

    Science.gov (United States)

    Kuntz, Kip; Collier, Michael; Sibeck, David G.; Porter, F. Scott; Carter, J. A.; Cravens, Thomas; Omidi, N.; Robertson, Ina; Sembay, S.; Snowden, Steven L.

    2008-01-01

    All of the solar wind energy that powers magnetospheric processes passes through the magnetosheath and magnetopause. Global images of the magnetosheath and magnetopause boundary layers will resolve longstanding controversy surrounding fundamental phenomena that occur at the magnetopause and provide information needed to improve operational space weather models. Recent developments showing that soft X-rays (0.15-1 keV) result from high charge state solar wind ions undergoing charge exchange recombination through collisions with exospheric neutral atoms has led to the realization that soft X-ray imaging can provide global maps of the high-density shocked solar wind within the magnetosheath and cusps, regions lying between the lower density solar wind and magnetosphere. We discuss an instrument concept called the Sheath Transport Observer for the Redistribution of Mass (STORM), an X-ray imager suitable for simultaneously imaging the dayside magnetosheath, the magnetopause boundary layers, and the cusps.

  18. The Sheath Transport Observer for the Redistribution of Mass (STORM) Imager

    Science.gov (United States)

    Collier, Michael R.; Sibeck, David G.; Porter, F. Scott; Burch, J.; Carter, J. A.; Cravens, Thomas; Kuntz, Kip; Omidi, N.; Read, A.; Robertson, Ina; hide

    2010-01-01

    All of the solar wind energy that powers magnetospheric processes passes through the magnetosheath and magnetopause. Global images of the magnetosheath and magnetopause boundary layers will resolve longstanding controversies surrounding fundamental phenomena that occur at the magnetopause and provide information needed to improve operational space weather models. Recent developments showing that soft X-rays (0.15-1 keV) result from high charge state solar wind ions undergoing charge exchange recombination through collisions with exospheric neutral atoms has led to the realization that soft X-ray imaging can provide global maps of the high-density shocked solar wind within the magnetosheath and cusps, regions lying between the lower density solar wind and magnetosphere. We discuss an instrument concept called the Sheath Transport Observer for the Redistribution of Mass (STORM), an X-ray imager suitable for simultaneously imaging the dayside magnetosheath, the magnetopause boundary layers, and the cusps.

  19. Surface analysis of lipids by mass spectrometry: more than just imaging.

    Science.gov (United States)

    Ellis, Shane R; Brown, Simon H; In Het Panhuis, Marc; Blanksby, Stephen J; Mitchell, Todd W

    2013-10-01

    Mass spectrometry is now an indispensable tool for lipid analysis and is arguably the driving force in the renaissance of lipid research. In its various forms, mass spectrometry is uniquely capable of resolving the extensive compositional and structural diversity of lipids in biological systems. Furthermore, it provides the ability to accurately quantify molecular-level changes in lipid populations associated with changes in metabolism and environment; bringing lipid science to the "omics" age. The recent explosion of mass spectrometry-based surface analysis techniques is fuelling further expansion of the lipidomics field. This is evidenced by the numerous papers published on the subject of mass spectrometric imaging of lipids in recent years. While imaging mass spectrometry provides new and exciting possibilities, it is but one of the many opportunities direct surface analysis offers the lipid researcher. In this review we describe the current state-of-the-art in the direct surface analysis of lipids with a focus on tissue sections, intact cells and thin-layer chromatography substrates. The suitability of these different approaches towards analysis of the major lipid classes along with their current and potential applications in the field of lipid analysis are evaluated. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. High mass and spatial resolution mass spectrometry imaging of Nicolas Poussin painting cross section by cluster TOF-SIMS.

    Science.gov (United States)

    Noun, M; Van Elslande, E; Touboul, D; Glanville, H; Bucklow, S; Walter, P; Brunelle, A

    2016-12-01

    The painting Rebecca and Eliezer at the Well, which hangs in the Fitzwilliam Museum, Cambridge, UK, is possibly one of the last figure painting executed by Nicolas Poussin at the very end of his life and is usually dated to the early 1660s. In this perspective special feature, Philippe Walter, Alain Brunelle and colleagues give new insights on the artist's working methods by a careful stateof-the-art imaging ToF-SIMS study of one sample taken on the edge of the painting. This approach allowed for the identification of the pigments used in the painting, their nature and components and those of the ground and preparatory layers, with the identification of the binder(s) and possible other additions of organic materials such as glue. This study paves the way to a wider use of ToF-SIMS for the analysis of ancient cultural heritage artefacts. Dr. Walter is the Director of the Molecular and Structural Archeology Laboratory (Université Pierre et Marie Curie, Paris, France). Dr. Brunelle is Head of the Mass Spectrometry Laboratory at the Institut de Chimie des Substances Naturelles (CNRS, Gif-sur-Yvette, France). Their long standing collaboration has led to several seminal publications on the analysis of ancient artefacts by mass spectrometry. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Internal Carotid Artery Ectasia: The Value of Imaging Studies Prior to Biopsy of a Retropharyngeal Mass

    Directory of Open Access Journals (Sweden)

    Kenneth Chan

    2010-11-01

    Full Text Available The presence of retropharyngeal tissue mass often raises the suspicion of malignancy, especially in elderly patients. This prompts urgent biopsy to investigate tissue histology. We discuss a case where this is contraindicated as the retropharyngeal mass was illustrated by CT scanning and confirmed with MRI to be a tortuous coursing internal carotid artery. An awareness of this unusual anatomical variation and a careful interpretation of imaging studies both at the stage of differential diagnosis and pre-operative screening are essential to avoid damage to important structures, causing unnecessary complications.

  2. Document authentication at molecular levels using desorption atmospheric pressure chemical ionization mass spectrometry imaging.

    Science.gov (United States)

    Li, Ming; Jia, Bin; Ding, Liying; Hong, Feng; Ouyang, Yongzhong; Chen, Rui; Zhou, Shumin; Chen, Huanwen; Fang, Xiang

    2013-09-01

    Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI-MS), which was operated in either a gasless, solvent-free or methanol vapor-assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI-MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI-MS imaging differentiated a 10-min old from two 4 h old samples. Non-destructive forensic analysis of forged signatures either handwritten or computer-assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI-MS. The experimental results show that DAPCI-MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.

  3. Migrant Image as an "Other Some" in the Russian Mass Media

    Directory of Open Access Journals (Sweden)

    Roman P. Bakanov

    2017-11-01

    Full Text Available This article reveals the main approaches and methods of forming a perception stereotype of the migrant image as "other some" in the Russian mass media. The authors of this article analyzed three federal print publications - "Rossiyskaya Gazeta", "Trud" and "Komsomolskaya Pravda", characterized as mass editions, which enabled to make the most complete coverage of several segments of the readership and to highlight the most widespread meaning of the "migrant" concept in the public consciousness. The study of the dynamics of using the "migrant" concept for the period of 2000-2013 in the Russian print media made it possible to conclude that there were shifts towards a positive assessment of "other some". If the "language of enmity" was used in the public consciousness to form the migrant image at the beginning of the period under investigation, which led to the consolidation of migrant phobia, then the situation changed by 2013 - the migrant image was more often associated with a victim of interethnic tension and corruption. The new migrant image is the image of a migrant who has not found a better life, but has adopted Russia as a second home and therefore trying to adopt new standards and living conditions and helping to solve many of the social and economic problems of Russian society.

  4. Characterization of low-mass deformable mirrors and ASIC drivers for high-contrast imaging

    Science.gov (United States)

    Mejia Prada, Camilo; Yao, Li; Wu, Yuqian; Roberts, Lewis C.; Shelton, Chris; Wu, Xingtao

    2017-09-01

    The development of compact, high performance Deformable Mirrors (DMs) is one of the most important technological challenges for high-contrast imaging on space missions. Microscale Inc. has fabricated and characterized piezoelectric stack actuator deformable mirrors (PZT-DMs) and Application-Specific Integrated Circuit (ASIC) drivers for direct integration. The DM-ASIC system is designed to eliminate almost all cables, enabling a very compact optical system with low mass and low power consumption. We report on the optical tests used to evaluate the performance of the DM and ASIC units. We also compare the results to the requirements for space-based high-contrast imaging of exoplanets.

  5. Imaging characteristics of lipofibromatosis presenting as a shoulder mass in a 16-month-old girl

    International Nuclear Information System (INIS)

    Walton, James R.; Donaldson, Matthew M.; Mazuru, Dana G.; Green, Brian A.

    2010-01-01

    Lipofibromatosis is a rare, benign fibrofatty tumor of childhood. Since the tumor was first characterized in 2000, only a few additional cases have been reported. The classic presentation of lipofibromatosis is a slow-growing mass arising in a distal extremity, with boys more commonly affected than girls. We report a 16-month-old girl who presented with a lipofibromatosis in her left scapular region that increased 30% in size during a 6-week period. Although previous case reports of lipofibromatosis have emphasized immunohistological findings, this paper focuses on imaging findings and discusses the utility of imaging in the differential diagnosis of pediatric soft-tissue tumors. (orig.)

  6. Imaging characteristics of lipofibromatosis presenting as a shoulder mass in a 16-month-old girl

    Energy Technology Data Exchange (ETDEWEB)

    Walton, James R.; Donaldson, Matthew M.; Mazuru, Dana G. [University of Missouri School of Medicine, Department of Radiology, Columbia, MO (United States); Green, Brian A. [University of Missouri School of Medicine, Department of Radiology, Columbia, MO (United States); Memphis Radiological, PC, Memphis, TN (United States)

    2010-12-15

    Lipofibromatosis is a rare, benign fibrofatty tumor of childhood. Since the tumor was first characterized in 2000, only a few additional cases have been reported. The classic presentation of lipofibromatosis is a slow-growing mass arising in a distal extremity, with boys more commonly affected than girls. We report a 16-month-old girl who presented with a lipofibromatosis in her left scapular region that increased 30% in size during a 6-week period. Although previous case reports of lipofibromatosis have emphasized immunohistological findings, this paper focuses on imaging findings and discusses the utility of imaging in the differential diagnosis of pediatric soft-tissue tumors. (orig.)

  7. Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.

    Science.gov (United States)

    Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans

    2018-06-01

    In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.

  8. Detection of high molecular weight proteins by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Mainini, Veronica; Bovo, Giorgio; Chinello, Clizia; Gianazza, Erica; Grasso, Marco; Cattoretti, Giorgio; Magni, Fulvio

    2013-06-01

    MALDI imaging mass spectrometry (IMS) is a unique technology to explore the spatial distribution of biomolecules directly on tissues. It allows the in situ investigation of a large number of small proteins and peptides. Detection of high molecular weight proteins through MALDI IMS still represents an important challenge, as it would allow the direct investigation of the distribution of more proteins involved in biological processes, such as cytokines, enzymes, neuropeptide precursors and receptors. In this work we compare the traditional method performed with sinapinic acid with a comparable protocol using ferulic acid as the matrix. Data show a remarkable increase of signal acquisition in the mass range of 20k to 150k Th. Moreover, we report molecular images of biomolecules above 70k Th, demonstrating the possibility of expanding the application of this technology both in clinical investigations and basic science.

  9. MASS MOVEMENTS' DETECTION IN HIRISE IMAGES OF THE NORTH POLE OF MARS

    Directory of Open Access Journals (Sweden)

    L. Fanara

    2016-06-01

    Full Text Available We are investigating change detection techniques to automatically detect mass movements at the steep north polar scarps of Mars, in order to improve our understanding of these dynamic processes. Here we focus on movements of blocks specifically. The precise detection of such small changes requires an accurate co-registration of the images, which is achieved by ortho-rectifying them using High Resolution Imaging Science Experiment (HiRISE Digital Terrain Models (DTMs. Moreover, we deal with the challenge of deriving the true shape of the moved blocks. In a next step, these results are combined with findings based on HiRISE DTMs from different points in time in order to estimate the volume of mass movements.

  10. Automatic extraction of myocardial mass and volumes using parametric images from dynamic nongated PET

    DEFF Research Database (Denmark)

    Harms, Hendrik Johannes; Hansson, Nils Henrik Stubkjær; Tolbod, Lars Poulsen

    2016-01-01

    Dynamic cardiac positron emission tomography (PET) is used to quantify molecular processes in vivo. However, measurements of left-ventricular (LV) mass and volumes require electrocardiogram (ECG)-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using non......-gated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls (HC) underwent a 27-min 11C-acetate PET/CT scan and cardiac magnetic resonance imaging (CMR). HC were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were......LV and WT only and an overestimation for LVEF at lower values. Intra- and inter-observer correlations were >0.95 for all PET measurements. PET repeatability accuracy in HC was comparable to CMR. CONCLUSION: LV mass and volumes are accurately and automatically generated from dynamic 11C-acetate PET without...

  11. Molecular imaging of myocardial infarction with Gadofluorine P – A combined magnetic resonance and mass spectrometry imaging approach

    Directory of Open Access Journals (Sweden)

    Fabian Lohöfer

    2018-04-01

    Full Text Available Background: Molecular MRI is becoming increasingly important for preclinical research. Validation of targeted gadolinium probes in tissue however has been cumbersome up to now. Novel methodology to assess gadolinium distribution in tissue after in vivo application is therefore needed. Purpose: To establish combined Magnetic Resonance Imaging (MRI and Mass Spectrometry Imaging (MSI for improved detection and quantification of Gadofluorine P deposition in scar formation and myocardial remodeling. Materials and methods: Animal studies were performed according to institutionally approved protocols. Myocardial infarction was induced by permanent ligation of the left ascending artery (LAD in C57BL/6J mice. MRI was performed at 7T at 1 week and 6 weeks after myocardial infarction. Gadofluorine P was used for dynamic T1 mapping of extracellular matrix synthesis during myocardial healing and compared to Gd-DTPA. After in vivo imaging contrast agent concentration as well as distribution in tissue were validated and quantified by spatially resolved Matrix-Assisted Laser Desorption Ionization (MALDI MSI and Laser Ablation – Inductively Coupled Plasma – Mass Spectrometry (LA-ICP-MS imaging. Results: Both Gadofluorine P enhancement as well as local tissue content in the myocardial scar were highest at 15 minutes post injection. R1 values increased from 1 to 6 weeks after MI (1.62 s−1 vs 2.68 s−1, p = 0.059 paralleled by an increase in Gadofluorine P concentration in the infarct from 0.019 mM at 1 week to 0.028 mM at 6 weeks (p = 0.048, whereas Gd-DTPA enhancement showed no differences (3.95 s−1 vs 3.47 s−1, p = 0.701. MALDI-MSI results were corroborated by elemental LA-ICP-MS of Gadolinium in healthy and infarcted myocardium. Histology confirmed increased extracellular matrix synthesis at 6 weeks compared to 1 week. Conclusion: Adding quantitative MSI to MR imaging enables a quantitative validation of Gadofluorine P distribution in the heart

  12. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    DEFF Research Database (Denmark)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka

    2017-01-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identi......Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could...... be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for Me......V Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples...

  13. Assessment of left ventricular mass in sequential studies with cine MR imaging

    International Nuclear Information System (INIS)

    Tomei, E.; Semelka, R.; Wagner, S.; Mayo, J.; Chatterjee, K.; Parmley, W.W.; O'Sullivan, M.; Wolfe, C.L.; Caputo, G.; Higgins, C.B.

    1989-01-01

    The aim of this study was to measure left ventricular (LV) mass in 11 healthy volunteers, 10 patients with dilated cardiomyopathy, and eight patients with LV hypertrophy (LVH), using two sequential studies to compare the characteristics of LV mass in the same subject and in different clinical situations. All subjects underwent short- axis cine MR imaging at 1.5 T. Each subject had two separate studies: the healthy volunteers within 6 months and those with cardiac disease within 1 week. Measurements (both end- systolic and end-diastolic) included LV mass, LV mass index, and wall thickness. LV mass was substantially increased in both DCM and LVH. The interstudy variability for end- systolic and end-diastolic mass was 5.2% and 3.8%, respectively, for healthy volunteers, 5.2% and 4.0% for LVH, and 3.8% and 6.1% for DCM. The low variability indicates the reproducibility of this technique in sequential studies when no change is expected

  14. Exquisite Nova Light Curves from the Solar Mass Ejection Imager (SMEI)

    OpenAIRE

    Hounsell, R.; Bode, M. F.; Hick, P. P.; Buffington, A.; Jackson, B. V.; Clover, J. M.; Shafter, A. W.; Darnley, M. J.; Mawson, N. R.; Steele, I. A.; Evans, A.; Eyres, S. P. S.; O'Brien, T. J.

    2010-01-01

    We present light curves of three classical novae (KT Eridani, V598 Puppis, V1280 Scorpii) and one recurrent nova (RS Ophiuchi) derived from data obtained by the Solar Mass Ejection Imager (SMEI) on board the Coriolis satellite. SMEI provides near complete sky-map coverage with precision visible-light photometry at 102-minute cadence. The light curves derived from these sky maps offer unprecedented temporal resolution around, and especially before, maximum light, a phase of the nova eruption n...

  15. Imaging mass spectrometry and genome mining reveal highly antifungal virulence factor of mushroom soft rot pathogen.

    Science.gov (United States)

    Graupner, Katharina; Scherlach, Kirstin; Bretschneider, Tom; Lackner, Gerald; Roth, Martin; Gross, Harald; Hertweck, Christian

    2012-12-21

    Caught in the act: imaging mass spectrometry of a button mushroom infected with the soft rot pathogen Janthinobacterium agaricidamnosum in conjunction with genome mining revealed jagaricin as a highly antifungal virulence factor that is not produced under standard cultivation conditions. The structure of jagaricin was rigorously elucidated by a combination of physicochemical analyses, chemical derivatization, and bioinformatics. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Modeling observations of solar coronal mass ejections with heliospheric imagers verified with the eliophysics System Observatory

    Czech Academy of Sciences Publication Activity Database

    Möstl, C.; Isavnin, A.; Boakes, P. D.; Kilpua, E. K. J.; Davies, J. A.; Harrison, R. A.; Barnes, D.; Krupař, Vratislav; Eastwood, J.; Good, S. W.; Forsyth, R. J.; Bothmer, V.; Reiss, M. A.; Amerstorfer, T.; Winslow, R. M.; Anderson, B.J.; Philpott, L. C.; Rodriguez, L.; Rouillard, A. P.; Gallagher, P.; Nieves-Chinchilla, T.; Zhang, T. L.

    2017-01-01

    Roč. 15, č. 7 (2017), s. 955-970 ISSN 1539-4956 R&D Projects: GA ČR(CZ) GJ17-06818Y Institutional support: RVO:68378289 Keywords : space weather * coronal mass ejections * STEREO * heliospheric imagers * Heliophysics System Observatory * heliophysics Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) http://onlinelibrary.wiley.com/doi/10.1002/2017SW001614/full

  17. Regional differences in brain glucose metabolism determined by imaging mass spectrometry

    OpenAIRE

    André Kleinridders; Heather A. Ferris; Michelle L. Reyzer; Michaela Rath; Marion Soto; M. Lisa Manier; Jeffrey Spraggins; Zhihong Yang; Robert C. Stanton; Richard M. Caprioli; C. Ronald Kahn

    2018-01-01

    Objective: Glucose is the major energy substrate of the brain and crucial for normal brain function. In diabetes, the brain is subject to episodes of hypo- and hyperglycemia resulting in acute outcomes ranging from confusion to seizures, while chronic metabolic dysregulation puts patients at increased risk for depression and Alzheimer's disease. In the present study, we aimed to determine how glucose is metabolized in different regions of the brain using imaging mass spectrometry (IMS). Metho...

  18. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    Science.gov (United States)

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Histology-directed and imaging mass spectrometry: an emerging technology in ectopic calcification

    OpenAIRE

    Taverna, Domenico; Boraldi, Federica; De Santis, Giorgio; Caprioli, Richard M; Quaglino, Daniela

    2015-01-01

    The present study was designed to demonstrate the potential of an optimized histology directed protein identification combined with imaging mass spectrometry technology to reveal and identify molecules associated to ectopic calcification in human tissue. As a proof of concept, mineralized and non-mineralized areas were compared within the same dermal tissue obtained from a patient affected by Pseudoxanthoma elasticum, a genetic disorder characterized by calcification only at specific sites of...

  20. Identification of Biomarkers of Necrosis in Xenografts Using Imaging Mass Spectrometry.

    Science.gov (United States)

    Fernández, Roberto; Garate, Jone; Lage, Sergio; Terés, Silvia; Higuera, Mónica; Bestard-Escalas, Joan; López, Daniel H; Guardiola-Serrano, Francisca; Escribá, Pablo V; Barceló-Coblijn, Gwendolyn; Fernández, José A

    2016-02-01

    Xenografts are commonly used to test the effect of new drugs on human cancer. However, because of their heterogeneity, analysis of the results is often controversial. Part of the problem originates in the existence of tumor cells at different metabolic stages: from metastatic to necrotic cells, as it happens in real tumors. Imaging mass spectrometry is an excellent solution for the analysis of the results as it yields detailed information not only on the composition of the tissue but also on the distribution of the biomolecules within the tissue. Here, we use imaging mass spectrometry to determine the distribution of phosphatidylcholine (PC), phosphatidylethanolamine (PE), and their plasmanyl- and plasmenylether derivatives (PC-P/O and PE-P/O) in xenografts of five different tumor cell lines: A-549, NCI-H1975, BX-PC3, HT29, and U-87 MG. The results demonstrate that the necrotic areas showed a higher abundance of Na(+) adducts and of PC-P/O species, whereas a large abundance of PE-P/O species was found in all the xenografts. Thus, the PC/PC-ether and Na(+)/K(+) ratios may highlight the necrotic areas while an increase on the number of PE-ether species may be pointing to the existence of viable tumor tissues. Furthermore, the existence of important changes in the concentration of Na(+) and K(+) adducts between different tissues has to be taken into account while interpreting the imaging mass spectrometry results. Graphical Abstract ᅟ.

  1. MALDI FTICR IMS of Intact Proteins: Using Mass Accuracy to Link Protein Images with Proteomics Data

    Science.gov (United States)

    Spraggins, Jeffrey M.; Rizzo, David G.; Moore, Jessica L.; Rose, Kristie L.; Hammer, Neal D.; Skaar, Eric P.; Caprioli, Richard M.

    2015-06-01

    MALDI imaging mass spectrometry is a highly sensitive and selective tool used to visualize biomolecules in tissue. However, identification of detected proteins remains a difficult task. Indirect identification strategies have been limited by insufficient mass accuracy to confidently link ion images to proteomics data. Here, we demonstrate the capabilities of MALDI FTICR MS for imaging intact proteins. MALDI FTICR IMS provides an unprecedented combination of mass resolving power (~75,000 at m/z 5000) and accuracy (differentiate a series of oxidation products of S100A8 ( m/z 10,164.03, -2.1ppm), a subunit of the heterodimer calprotectin, in kidney tissue from mice infected with Staphylococcus aureus. S100A8 - M37O/C42O3 ( m/z 10228.00, -2.6ppm) was found to co-localize with bacterial microcolonies at the center of infectious foci. The ability of MALDI FTICR IMS to distinguish S100A8 modifications is critical to understanding calprotectin's roll in nutritional immunity.

  2. Hybrid Imaging Labels: Providing the Link Between Mass Spectrometry-Based Molecular Pathology and Theranostics

    Science.gov (United States)

    Buckle, Tessa; van der Wal, Steffen; van Malderen, Stijn J.M.; Müller, Larissa; Kuil, Joeri; van Unen, Vincent; Peters, Ruud J.B.; van Bemmel, Margaretha E.M.; McDonnell, Liam A.; Velders, Aldrik H.; Koning, Frits; Vanhaeke, Frank; van Leeuwen, Fijs W. B.

    2017-01-01

    Background: Development of theranostic concepts that include inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) imaging can be hindered by the lack of a direct comparison to more standardly used methods for in vitro and in vivo evaluation; e.g. fluorescence or nuclear medicine. In this study a bimodal (or rather, hybrid) tracer that contains both a fluorescent dye and a chelate was used to evaluate the existence of a direct link between mass spectrometry (MS) and in vitro and in vivo molecular imaging findings using fluorescence and radioisotopes. At the same time, the hybrid label was used to determine whether the use of a single isotope label would allow for MS-based diagnostics. Methods: A hybrid label that contained both a DTPA chelate (that was coordinated with either 165Ho or 111In) and a Cy5 fluorescent dye was coupled to the chemokine receptor 4 (CXCR4) targeting peptide Ac-TZ14011 (hybrid-Cy5-Ac-TZ4011). This receptor targeting tracer was used to 1) validate the efficacy of (165Ho-based) mass-cytometry in determining the receptor affinity via comparison with fluorescence-based flow cytometry (Cy5), 2) evaluate the microscopic binding pattern of the tracer in tumor cells using both fluorescence confocal imaging (Cy5) and LA-ICP-MS-imaging (165Ho), 3) compare in vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) after intravenous administration of hybrid-Cy5-Ac-TZ4011 in tumor-bearing mice. Finally, LA-ICP-MS-imaging (165Ho) was linked to fluorescence-based analysis of excised tissue samples (Cy5). Results: Analysis with both mass-cytometry and flow cytometry revealed a similar receptor affinity, respectively 352 ± 141 nM and 245 ± 65 nM (p = 0.08), but with a much lower detection sensitivity for the first modality. In vitro LA-ICP-MS imaging (165Ho) enabled clear discrimination between CXCR4 positive and negative cells, but fluorescence microscopy was required to determine the

  3. Imaging mass spectrometry in papillary thyroid carcinoma for the identification and validation of biomarker proteins.

    Science.gov (United States)

    Min, Kyueng-Whan; Bang, Joo-Young; Kim, Kwang Pyo; Kim, Wan-Seop; Lee, Sang Hwa; Shanta, Selina Rahman; Lee, Jeong Hwa; Hong, Ji Hye; Lim, So Dug; Yoo, Young-Bum; Na, Chan-Hyun

    2014-07-01

    Direct tissue imaging mass spectrometry (IMS) by matrix-assisted laser desorption ionization and time-of-flight (MALDI-TOF) mass spectrometry has become increasingly important in biology and medicine, because this technology can detect the relative abundance and spatial distribution of interesting proteins in tissues. Five thyroid cancer samples, along with normal tissue, were sliced and transferred onto conductive glass slides. After laser scanning by MALDI-TOF equipped with a smart beam laser, images were created for individual masses and proteins were classified at 200-µm spatial resolution. Based on the spatial distribution, region-specific proteins on a tumor lesion could be identified by protein extraction from tumor tissue and analysis using liquid chromatography with tandem mass spectrometry (LC-MS/MS). Using all the spectral data at each spot, various intensities of a specific peak were detected in the tumor and normal regions of the thyroid. Differences in the molecular weights of expressed proteins between tumor and normal regions were analyzed using unsupervised and supervised clustering. To verify the presence of discovered proteins through IMS, we identified ribosomal protein P2, which is specific for cancer. We have demonstrated the feasibility of IMS as a useful tool for the analysis of tissue sections, and identified the tumor-specific protein ribosomal protein P2.

  4. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    Science.gov (United States)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko

    2017-09-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.

  5. The role of magnetic resonance imaging and ultrasound in patients with adnexal masses

    International Nuclear Information System (INIS)

    Sohaib, S.A.; Mills, T.D.; Sahdev, A.; Webb, J.A.W.; VanTrappen, P.O.; Jacobs, I.J.; Reznek, R.H.

    2005-01-01

    AIMS: To evaluate the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) in characterizing adnexal masses, and to determine which patients may benefit from MRI. METHODS: We prospectively studied 72 women (mean age 53 years, range 19 to 86 years) with clinically suspected adnexal masses. A single experienced sonographer performed transabdominal and transvaginal greyscale spectral and colour Doppler examinations. MRI was carried out on a 1.5T system using T1, T2 and fat-suppressed T1-weighted sequences before and after intravenous injection of gadolinium. The adnexal masses were categorized as benign or malignant without knowledge of clinical details, according to the imaging features which were compared with the surgical and pathological findings. RESULTS: For characterizing lesions as malignant, the sensitivity, specificity and accuracy of MRI were 96.6%, 83.7% and 88.9%, respectively, and of US were 100%, 39.5% and 63.9%, respectively. MRI was more specific (p<0.05) than US. Both MRI and US correctly diagnosed 17 (24%) cases with benign and 28 (39%) cases with malignant masses. MRI correctly diagnosed 19 (26%) cases with benign lesion(s), which on US were thought to be malignant. The age, menopausal status and CA-125 levels in these women made benign disease likely, but US features were suggestive of malignancy (large masses and solid-cystic lesions with nodules). CONCLUSION: MRI is more specific and accurate than US and Doppler assessment for characterizing adnexal masses. Women who clinically have a relatively low risk of malignancy but who have complex sonographic features may benefit from MRI

  6. Mass distribution of fission fragments using SSNTDs based image analysis system

    International Nuclear Information System (INIS)

    Kolekar, R.V.; Sharma, D.N.

    2006-01-01

    Lexan polycarbonate track detector was used to obtain mass distribution of fission fragments from 252 Cf planchette source, Normally, if the fission fragments are incident perpendicular to the lexan surface, the diameter of heavy fragment is greater than that of lighter fragment. In practical problems fission fragments are incident on the detector at all angles. So, in the present experiment, lexan detector was exposed to 252 Cf planchette source in 2π geometry. Fission fragments were incident on the detector with various angles. So the projected fission track length for fission fragment of same energy is different because of different angle of incidence. Image analysis software was used to measure the projected track length. But the problem is that for fission fragment having greater angle of incidence the entire track length is not focused on the surface. So reduced track length is measured. This problem is solved by taking two images, one at the surface and one at the tip of track and then overlapping both the images using image analysis software. The projected track length and the depth of the track were used to get the angle of incidence. Fission track lengths were measured for same angle of incidence. In all 500 track lengths were measured and plot for mass distribution for fission fragment was obtained.(author)

  7. Precision mass measurements using the Phase-Imaging Ion-Cyclotron-Resonance detection technique

    CERN Document Server

    Karthein, Jonas

    This thesis presents the implementation and improvement of the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) detection technique at the ISOLTRAP experiment, located at the ISOLDE / CERN, with the purpose of on-line high-precision and high-resolution mass spectrometry. Extensive simulation studies were performed with the aim of improving the phase-imaging resolution and finding the optimal position for detector placement. Following the outcome of these simulations, the detector was moved out of a region of electric-field distortion and closer to the center of the Penning trap, showing a dramatic improvement in the quality and reproducibility of the phase-imaging measurements. A new image reconstitution and analysis software for the MCP-PS detector was written in Python and ROOT and introduced in the framework of PI-ICR mass measurements. The state of the art in the field of time-of-flight ion-cyclotron-resonance measurements is illustrated through an analysis of on-line measurements of the mirror nuclei $...

  8. Characterization of breast masses by dynamic enhanced MR imaging. A logistic regression analysis

    International Nuclear Information System (INIS)

    Ikeda, O.; Morishita, S.; Kido, T.; Kitajima, M.; Yamashita, Y.; Takahashi, M.; Okamura, K.; Fukuda, S.

    1999-01-01

    Purpose: To identify features useful for differentiation between malignant and benign breast neoplasms using multivariate analysis of findings by MR imaging. Material and Methods: In a retrospective analysis, 61 patients with 64 breast masses underwent MR imaging and the time-signal intensity curves for precontrast dynamic postcontrast images were quantitatively analyzed. Statistical analysis was performed using a logistic regression model, which was prospectively tested in another 34 patients with suspected breast masses. Results: Univariate analysis revealed that the reliable indicators for malignancy were first the appearance of the tumor border, followed by the washout ratio, internal architecture after contrast enhancement, and peak time. The factors significantly associated with malignancy were irregular tumor border, followed by washout ratio, internal architecture, and peak time. For differentiation between benignity and malignancy, the maximum cut-off point was to be found between 0.47 and 0.51. In a prospective application of this model, 91% of the lesions were accurately discriminated as benign or malignant lesions. Conclusion: Combination of contrast-enhanced dynamic and postcontrast-enhanced MR imaging provided accurate data for the diagnosis of malignant neoplasms of the breast. The model had an accuracy of 91% (sensitivity 90%, specificity 93%). (orig.)

  9. Visualizing metabolite distribution and enzymatic conversion in plant tissues by desorption electrospray ionization mass spectrometry imaging

    DEFF Research Database (Denmark)

    Li, Bin; Baden, Camilla Knudsen; Hansen, Natascha Kristine Krahl

    2013-01-01

    In comparison to the technology platforms developed to localize transcripts and proteins, imaging tools for visualization of metabolite distributions in plant tissues are less well developed and lack versatility. This hampers our understanding of plant metabolism and dynamics. In this study we...... demonstrate that Desorption Electrospray Ionization Mass Spectrometry Imaging (DESI-MSI) of tissue imprints on porous Teflon can be used to accurately image the distribution of even labile plant metabolites such as hydroxynitrile glucosides, which normally undergo enzymatic hydrolysis by specific ß......-glucosidases upon cell disruption. This fast and simple sample preparation resulted in no substantial differences in the distribution and ratios of all hydroxynitrile glucosides between leaves from wildtype Lotus japonicus and a ß-glucosidase mutant plant lacking the ability to hydrolyze certain hydroxynitrile...

  10. Disparate appearance of intrascrotal masses during Tc-99m-pertechnetate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bocobo, G.C.; Turner, J.W.; Spencer, R.P.

    1986-10-01

    Two cases are presented of males with pain and swelling in the left testicular area. In the first, the left side had less perfusion than the right. Static images revealed a large photopenic area in the left testicular sac, with a medial area of hyperactivity. At surgery, there was a left epididymitis (corresponding to the small area of hyperactivity on the image) and a large collection of fluid probably secondary to the inflammation. The distention likely produced a tamponade effect with reduced perfusion. In the second case, there was slightly greater perfusion to the left. There was a semilunar area of activity equal to that of the background, with a surrounding band of intensely increased uptake. The right side showed the same findings on a smaller scale. There was an abscess involving each testis. Intrascrotal masses may distort the expected findings on testicular-scrotal imaging.

  11. Multi-isotope (carbon and chlorine) analysis for fingerprinting and site characterization at a fractured bedrock aquifer contaminated by chlorinated ethenes

    Energy Technology Data Exchange (ETDEWEB)

    Palau, Jordi, E-mail: jordi.palau@unine.ch [Departament de Cristal.lografia, Mineralogia i Dipòsits Minerals, Facultat de Geologia, Universitat de Barcelona, Martí i Franquès, s/n 08028 Barcelona (Spain); Marchesi, Massimo [Departament de Cristal.lografia, Mineralogia i Dipòsits Minerals, Facultat de Geologia, Universitat de Barcelona, Martí i Franquès, s/n 08028 Barcelona (Spain); Department of Earth and Environmental Sciences, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Chambon, Julie C.C. [Department of Environmental Engineering, Technical University of Denmark, 2800 Lyngby (Denmark); Aravena, Ramon [Department of Earth and Environmental Sciences, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Canals, Àngels [Departament de Cristal.lografia, Mineralogia i Dipòsits Minerals, Facultat de Geologia, Universitat de Barcelona, Martí i Franquès, s/n 08028 Barcelona (Spain); Binning, Philip J.; Bjerg, Poul L. [Department of Environmental Engineering, Technical University of Denmark, 2800 Lyngby (Denmark); Otero, Neus; Soler, Albert [Departament de Cristal.lografia, Mineralogia i Dipòsits Minerals, Facultat de Geologia, Universitat de Barcelona, Martí i Franquès, s/n 08028 Barcelona (Spain)

    2014-03-01

    The use of compound specific multi-isotope approach (C and Cl) in the characterization of a chlorinated ethenes contaminated fractured aquifer allows the identification of several sources and contaminant plumes, as well as the occurrence of biodegradation and mixing processes. The study site is located in Spain with contamination resulting in groundwater concentrations of up to 50 mg/L of trichloroethene (TCE), the most abundant chlorinated ethene, and 7 mg/L of tetrachloroethene (PCE). The potential sources of contamination including abandoned barrels, an underground tank, and a disposal lagoon, showed a wide range in δ{sup 13}C values from − 15.6 to − 40.5‰ for TCE and from − 18.5 to − 32.4‰ for PCE, allowing the use of isotope fingerprinting for tracing of the origin and migration of these contaminants in the aquifer. In contrast, there is no difference between the δ{sup 37}Cl values for TCE in the contaminant sources, ranging from + 0.53 to + 0.66‰. Variations of δ{sup 37}Cl and δ{sup 13}C in the different contaminant plumes were used to investigate the role of biodegradation in groundwater. Moreover, the isotopic data were incorporated into a reactive transport model for determination of whether the isotope pattern observed downstream from the tank's source could be explained by the simultaneous effect of mixing and biodegradation. The results demonstrate that a multi-isotope approach is a valuable tool for characterization of complex sites such as fractured bedrock aquifer contaminated by multiple sources, providing important information which can be used by consultants and site managers to prioritize and design more successful remediation strategies. - Highlights: • Origin and fate of CAHs in groundwater by means of multi CSIA ({sup 13}C,{sup 35}Cl) survey • Innovative/new approach tested in a fractured bedrock site • Differentiation of distinct CAH sources • Biodegradation and source mixing recognition in the aquifer.

  12. Identifying source and formation altitudes of nitrates in drinking water from Réunion Island, France, using a multi-isotopic approach.

    Science.gov (United States)

    Rogers, Karyne M; Nicolini, Eric; Gauthier, Virginie

    2012-09-01

    Nitrate concentrations, water isotopes (δ(2)H and δ(18)O(water)) and associated nitrate isotopes (δ(15)N(nitrate) and δ(18)O(nitrate)) from 10 drinking water wells, 5 fresh water springs and the discharge from 3 wastewater treatment stations in Réunion Island, located in the Indian Ocean, were analysed. We used a multi isotopic approach to investigate the extent of nitrate contamination, nitrate formation altitude and source of nitrates in Réunion Island's principal aquifer. Water from these study sites contained between 0.1 and 85.3 mg/L nitrate. δ(15)N(nitrate) values between +6 and +14‰ suggested the main sources of contamination were animal and/or human waste, rather than inorganic (synthetic) fertilisers, infiltrating through the subsurface into the saturated zone, due to rainfall leaching of the unsaturated zone at various altitudes of precipitation. Based on δ(15)N(nitrate) values alone, it was not possible to distinguish between animal and human activities responsible for the contamination of each specific catchment. However, using a multi isotope approach (δ(18)O(water) and δ(15)N(nitrate)), it was possible to relate the average altitude of rainfall infiltration (δ(18)O(water)) associated with the nitrate contamination (δ(18)O(nitrate)). This relationship between land use, rainfall recharge altitude and isotopic composition (δ(15)N(nitrate) and δ(18)O(water)) discriminated between the influences of human waste at lower (below 600 m elevation) or animal derived contamination (at elevations between 600 and 1300 m). By further comparing the theoretical altitude of nitrate formation calculated by the δ(18)O(nitrate), it was possible to determine that only 5 out of 15 fresh water wells and springs followed the conservative nitrate formation mechanism of 2/3δ(18)O(water)+1/3δ(18)O(air), to give nitrate formation altitudes which corresponded to land use activities. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Connecting imaging mass spectrometry and magnetic resonance imaging-based anatomical atlases for automated anatomical interpretation and differential analysis.

    Science.gov (United States)

    Verbeeck, Nico; Spraggins, Jeffrey M; Murphy, Monika J M; Wang, Hui-Dong; Deutch, Ariel Y; Caprioli, Richard M; Van de Plas, Raf

    2017-07-01

    Imaging mass spectrometry (IMS) is a molecular imaging technology that can measure thousands of biomolecules concurrently without prior tagging, making it particularly suitable for exploratory research. However, the data size and dimensionality often makes thorough extraction of relevant information impractical. To help guide and accelerate IMS data analysis, we recently developed a framework that integrates IMS measurements with anatomical atlases, opening up opportunities for anatomy-driven exploration of IMS data. One example is the automated anatomical interpretation of ion images, where empirically measured ion distributions are automatically decomposed into their underlying anatomical structures. While offering significant potential, IMS-atlas integration has thus far been restricted to the Allen Mouse Brain Atlas (AMBA) and mouse brain samples. Here, we expand the applicability of this framework by extending towards new animal species and a new set of anatomical atlases retrieved from the Scalable Brain Atlas (SBA). Furthermore, as many SBA atlases are based on magnetic resonance imaging (MRI) data, a new registration pipeline was developed that enables direct non-rigid IMS-to-MRI registration. These developments are demonstrated on protein-focused FTICR IMS measurements from coronal brain sections of a Parkinson's disease (PD) rat model. The measurements are integrated with an MRI-based rat brain atlas from the SBA. The new rat-focused IMS-atlas integration is used to perform automated anatomical interpretation and to find differential ions between healthy and diseased tissue. IMS-atlas integration can serve as an important accelerator in IMS data exploration, and with these new developments it can now be applied to a wider variety of animal species and modalities. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann. Copyright © 2017. Published by Elsevier B.V.

  14. Comparison of Diagnostic Accuracy of Breast Masses Using Digitized Images Versus Screen-Film Mammography

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Xinyu Yao; Yanhui Yang; Kuncheng Li

    2008-01-01

    Background: Medical film digitizers play an important transitory role as digital-analogue bridges in radiology. Digitized mammograms require evaluation of performance to assure medical image quality. Purpose: To compare the diagnostic accuracy in the interpretation of breast masses using original screen-film mammograms versus digitized images. Material and Methods: A total of 72 female patients between 55 and 81 years of age suspected of having breast cancer were selected by two non-observing radiologists. Of these, 31 cases were benign lesions and 41 cases were cancer. The mammography films were digitized using a laser film digitizer. Three radiologists, each with more than 10 years of experience in mammography, interpreted the screen-film mammograms and digitized images respectively. The time interval was 4 weeks. A four-point malignancy scale was used, with 1 defined as definitely not malignant, 2 as probably not malignant, 3 as probably malignant, and 4 as definitely malignant. Receiver operating characteristic (Roc) curves, sensitivity, and specificity were compared. Results: The average area-under-the-curve (Az) value of the original screen-film mammograms was 0.921, and the average Az value of the digitized images was 0.859. This difference was not statistically significant (P=0.131). The detection specificity of extremely dense breasts was lower than that for other breast compositions for both digitized images and screen-film mammograms. No statistical significance in sensitivity and specificity was observed between digitized images and mammograms for each breast composition. Original screen-film mammograms were observed to perform better than digitized images. Conclusion: Digitized images with a spatial resolution of 175 μm can be used instead of screen-film mammograms in the diagnosis of breast cancer

  15. Mass balance of Mars' residual south polar cap from CTX images and other data

    Science.gov (United States)

    Thomas, P. C.; Calvin, W.; Cantor, B.; Haberle, R.; James, P. B.; Lee, S. W.

    2016-04-01

    Erosion of pits in the residual south polar cap (RSPC) of Mars concurrent with deposition and fluctuating cap boundaries raises questions about the mass balance and long term stability of the cap. Determining a mass balance by measurement of a net gain or loss of atmospheric CO2 by direct pressure measurements (Haberle, R.M. et al. [2014]. Secular climate change on Mars: An update using one Mars year of MSL pressure data. American Geophysical Union (Fall). Abstract 3947), although perhaps the most direct method, has so far given ambiguous results. Estimating volume changes from imaging data faces challenges, and has previously been attempted only in isolated areas of the cap. In this study we use 6 m/pixel Context Imager (CTX) data from Mars year 31 to map all the morphologic units of the RSPC, expand the measurement record of pit erosion rates, and use high resolution images to place limits on vertical changes in the surface of the residual cap. We find the mass balance in Mars years 9-31 to be -6 to +4 km3/♂y, or roughly -0.039% to +0.026% of the mean atmospheric CO2 mass/♂y. The indeterminate sign results chiefly from uncertainty in the amounts of deposition or erosion on the upper surfaces of deposits (as opposed to scarp retreat). Erosion and net deposition in this period appear to be controlled by summertime planetary scale dust events, the largest occurring in MY 9, another, smaller one in MY 28. The rates of erosion and the deposition observed since MY 9 appear to be consistent with the types of deposits and erosional behavior found in most of the residual cap. However, small areas (100 ♂y) of depositional and/or erosional conditions different from those occurring in the period since MY 9, although these environmental differences could be subtle.

  16. A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    Selecting optimal features from a large image feature pool remains a major challenge in developing computer-aided detection (CAD) schemes of medical images. The objective of this study is to investigate a new approach to significantly improve efficacy of image feature selection and classifier optimization in developing a CAD scheme of mammographic masses. An image dataset including 1600 regions of interest (ROIs) in which 800 are positive (depicting malignant masses) and 800 are negative (depicting CAD-generated false positive regions) was used in this study. After segmentation of each suspicious lesion by a multilayer topographic region growth algorithm, 271 features were computed in different feature categories including shape, texture, contrast, isodensity, spiculation, local topological features, as well as the features related to the presence and location of fat and calcifications. Besides computing features from the original images, the authors also computed new texture features from the dilated lesion segments. In order to select optimal features from this initial feature pool and build a highly performing classifier, the authors examined and compared four feature selection methods to optimize an artificial neural network (ANN) based classifier, namely: (1) Phased Searching with NEAT in a Time-Scaled Framework, (2) A sequential floating forward selection (SFFS) method, (3) A genetic algorithm (GA), and (4) A sequential forward selection (SFS) method. Performances of the four approaches were assessed using a tenfold cross validation method. Among these four methods, SFFS has highest efficacy, which takes 3%-5% of computational time as compared to GA approach, and yields the highest performance level with the area under a receiver operating characteristic curve (AUC) = 0.864 ± 0.034. The results also demonstrated that except using GA, including the new texture features computed from the dilated mass segments improved the AUC results of the ANNs optimized

  17. Characterization of mammographic masses based on level set segmentation with new image features and patient information

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan Heangping; Ge Jun; Hadjiiski, Lubomir; Helvie, Mark A.; Nees, Alexis; Wu Yita; Wei Jun; Zhou Chuan; Zhang Yiheng; Cui Jing

    2008-01-01

    Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A z value of 0.83±0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A z values were 0.85±0.01 and 0.87±0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening

  18. On the use of [18F]DOPA as an imaging biomarker for transplanted islet mass

    International Nuclear Information System (INIS)

    Eriksson, Olof; Mintz, Akiva; Liu, Chengyang; Yu, Ming; Naji, Ali; Alavi, Abass

    2014-01-01

    Islet transplantation is being developed as a potential cure for patients with type 1 diabetes. There is a need for non-invasive imaging techniques for the quantification of transplanted islets, as current transplantation sites are associated with a substantial loss of islet viability. The dopaminergic metabolic pathway is present in the islets; therefore, we propose Fluorine-18 labeled L-3,4-dihydroxyphenylalanine ([ 18 F]DOPA) as a biomarker for transplanted islet mass. The expression of enzymes involved in the dopaminergic metabolic pathway was investigated in both native and transplanted human islets. The specific uptake of [ 18 F]DOPA in islets and immortalized beta cells was studied in vitro by selective blocking of dopa decarboxylase (DDC). Initial in vivo positron emission tomography (PET) imaging of viable subcutaneous human islets was performed using [ 18 F]DOPA. DDC and vesicular monoamine transporter 2 are co-localized with insulin in the native human pancreas, and the expression is retained after transplantation. Islet uptake of the [ 18 F]DOPA could be modulated by inhibiting DDC, indicating that the uptake followed the normal dopaminergic metabolic pathway. In vivo imaging revealed [ 18 F]DOPA uptake at the site of the functional islet graft. Based on the in vitro and in vivo results presented in this study, we propose to further validate [ 18 F]DOPA-PET as a sensitive imaging modality for imaging extrahepatically transplanted islets. (author)

  19. Next-generation technologies for spatial proteomics: Integrating ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR imaging mass spectrometry for protein analysis.

    Science.gov (United States)

    Spraggins, Jeffrey M; Rizzo, David G; Moore, Jessica L; Noto, Michael J; Skaar, Eric P; Caprioli, Richard M

    2016-06-01

    MALDI imaging mass spectrometry is a powerful analytical tool enabling the visualization of biomolecules in tissue. However, there are unique challenges associated with protein imaging experiments including the need for higher spatial resolution capabilities, improved image acquisition rates, and better molecular specificity. Here we demonstrate the capabilities of ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR IMS platforms as they relate to these challenges. High spatial resolution MALDI-TOF protein images of rat brain tissue and cystic fibrosis lung tissue were acquired at image acquisition rates >25 pixels/s. Structures as small as 50 μm were spatially resolved and proteins associated with host immune response were observed in cystic fibrosis lung tissue. Ultra-high speed MALDI-TOF enables unique applications including megapixel molecular imaging as demonstrated for lipid analysis of cystic fibrosis lung tissue. Additionally, imaging experiments using MALDI FTICR IMS were shown to produce data with high mass accuracy (z 5000) for proteins up to ∼20 kDa. Analysis of clear cell renal cell carcinoma using MALDI FTICR IMS identified specific proteins localized to healthy tissue regions, within the tumor, and also in areas of increased vascularization around the tumor. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Protoplanetary disks around intermediate-mass stars: the asset of imaging in the mid-infrared

    International Nuclear Information System (INIS)

    Doucet, Coralie

    2006-01-01

    The accrued efficiency of the instruments in many wavelengths has allowed to show that most young stellar objects were surrounded by circumstellar matter distributed in a disk. Direct imaging of such systems is very difficult because of their narrow angular size and their weak luminosity in comparison with the star. Nowadays, 50 % of low-mass pre-main sequence stars, i.e. T Tauri stars, are surrounded by a disk. This proportion is less obvious for intermediate-mass stars, like Herbig Ae stars, that are less numerous and whose direct disk detection is more difficult. Until now, only the interpretation of the Spectral Energy Distribution (SED) of such objects allows to have access to the geometry of the disk. But the solutions are degenerated and several parameters fit the same SED. It is essential to have direct images of the objects, the only evidence of the presence of disks. This PhD allows to show that mid-infrared imaging could rise a part of the degeneracy of the disk's parameters linked to the fit of the SED for several objects and gives constraints on the minimum external radius and inclination of the disk. We present a new observation mode with VISIR, the mid-infrared imager and spectrometer on the VLT (ESO, Chile): the so-called BURST mode. This mode allows to reach the diffraction limit of the telescope. Thanks to mid-infrared imaging with this instrument, we were able, for the first time, to have access to the geometry of a disk (flared structure) around a massive star that was, until now, only deduced from the SED modelling. (author) [fr

  1. MALDI-Imaging Mass Spectrometry of Ochratoxin A and Fumonisins in Mold-Infected Food.

    Science.gov (United States)

    Hickert, Sebastian; Cramer, Benedikt; Letzel, Matthias C; Humpf, Hans-Ulrich

    2016-09-06

    Mycotoxins are toxic secondary metabolites produced by various fungi. Their distribution within contaminated material is of high interest to obtain insight into infection mechanisms and the possibility of reducing contamination during food processing. Various vegetable foodstuffs were infected with fungi of the genera Fusarium and Aspergillus. The localization of the produced mycotoxins was studied by matrix assisted laser desorption ionization time of flight imaging mass spectrometry (MALDI-MSI) of cryosections obtained from infected material. The results were confirmed by HPLC-electrospray ionization triple quadrupole mass spectrometry (HPLC/MS/MS). The mycotoxins ochratoxin A (OTA) and fumonisins of the B- and C-series (FB 1 , FB 2 , FB 3 , FB 4 , FC 2/3 , and FC 4 ) as well as partially hydrolyzed fumonisins (pHFB 1 , pHFB 2 , pHFB 3 , pHFC 1 , and pHFC 2/3 ) could successfully be detected by MALDI-IMS in mold-infested foodstuffs. The toxins are distributed differently in the material: OTA is co-localized with visible fungal spoilage while fumonisins could be detected throughout the whole sample. This work shows the applicability of MALDI-Imaging Mass Spectrometry (MALDI-MSI) to mycotoxin analysis. It has been demonstrated that the analyzed mycotoxins are differently distributed within moldy foodstuffs. These findings show the potential of MALDI-MSI for the localization of these hazardous compounds in various plant tissues. This article is protected by copyright. All rights reserved.

  2. Quantitative evaluation of small breast masses using a compartment model analysis on dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu; Morishita, Shoji; Kido, Taeko; Kitajima, Mika; Okamura, Kenji; Fukuda, Seiji [Kumamoto Rosai Hospital, Yatsushiro (Japan); Yamashita, Yasuyuki; Takahashi, Mutsumasa

    1998-07-01

    To differentiate between malignant and benign breast masses using a compartmental analysis, 55 patients with breast masses (fibroadenoma, n=22; invasive ductal carcinoma, n=29; noninvasive ductal carcinoma, n=8) underwent Gd-DTPA enhanced dynamic MR imaging. Dynamic MR images obtained using two-dimensional fat-saturated fast multiplanar corrupted gradient echo technique over 10 minutes following bolus injection of Gd-DTPA. The triexponential concentration curve of Gd-DTPA was fitted to a theoretical model based on compartmental analysis. Using this method, the transfer constant (or permeability surface product per unit volume of component k) and f{sub 3}/f{sub 1}=f were measured, where f{sub 1} represents tumor vessel volume and f{sub 3} represents extracellular volume. The k value was significantly greater (p<0.01) for malignant tumors, and the k value seen in cases of noninvasive ductal carcinoma was less than that for invasive ductal carcinoma. The f value was significantly smaller (p<0.01) for malignant tumors, whereas the f value for noninvasive ductal carcinoma was not significantly different from that for invasive ductal carcinoma. We believe that this type of compartmental analysis may be of value for the evaluation of breast masses. (author)

  3. Lithuania’s Images in Russian Mass Media after the Annexation of Crimea

    Directory of Open Access Journals (Sweden)

    Pugačiauskas Virgilijus

    2017-12-01

    Full Text Available One of the distinctive features of Russia’s confrontation with the West over the 2014-2016 period is the intensification of Russian propaganda both in foreign countries and within the state. Lithuania, whose relations with a major neighbour were not normalized, and which openly supported Ukraine’s position, attracted the additional attention of Russian mass media in which an incitement to anti- Lithuanian moods was bolstered. In this case, it is endeavoured to generally describe how the mass media (television and newspapers played a role in contriving a social construct and ascertain the Lithuanian quantitative characteristics which are presented in Russian mass media. Referring to the analysis, one can distinguish three prevailing negative images of Lithuania - that is, Russophobic and anti-Russian; a falsifier of history; and a failing and non-influential state. These images, being consistently and purposefully exploited in Russian information space, almost with no alternative sources, turned into undeniable truth for the majority of Russian citizens. This provides the Kremlin with vast possibilities of manipulation in constructing the tactics and strategy of geopolitical instability. On the other hand, one should not forget that such a negative picture of Lithuania serves as a way in which Russian society justifies Putin’s political system and demonstrates its superiority over the values of the Western world.

  4. Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

    Science.gov (United States)

    Picard de Muller, Gaël; Ait-Belkacem, Rima; Bonnel, David; Longuespée, Rémi; Stauber, Jonathan

    2017-12-01

    Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric - number of objects and total surface - information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. [Figure not available: see fulltext.

  5. Anti-theft device staining on banknotes detected by mass spectrometry imaging.

    Science.gov (United States)

    Correa, Deleon Nascimento; Zacca, Jorge Jardim; Rocha, Werickson Fortunato de Carvalho; Borges, Rodrigo; de Souza, Wanderley; Augusti, Rodinei; Eberlin, Marcos Nogueira; Vendramini, Pedro Henrique

    2016-03-01

    We describe the identification and limits of detection of ink staining by mass spectrometry imaging (MSI), as used in anti-theft devices (ATDs). Such ink staining is applied to banknotes during automated teller machine (ATM) explosions. Desorption electrospray ionization (DESI) coupled with high-resolution and high-accuracy orbitrap mass spectrometry (MS) and a moving stage device were applied to obtain 2D molecular images of the major dyes used for staining, that is, 1-methylaminoanthraquinone (MAAQ), rhodamine B (RB) and rhodamine 6G (R6G). MAAQ could not be detected because of its inefficient desorption by DESI from the banknote cellulose surface. By contrast, ATD staining on banknotes is perceptible by the human naked eye only at concentrations higher than 0.2 μg cm(-2), whereas both RB and R6G at concentrations 200 times lower (as low as 0.001 μg cm(-2)) could be easily detected and imaged by DESI-MSI, with selective and specific identification of each analyte and their spatial distribution on samples from suspects. This technique is non-destructive, and no sample preparation is required, which ensures sample preservation for further forensic investigations. Copyright © 2016. Published by Elsevier Ireland Ltd.

  6. Three-dimensional segmentation of the tumor mass in computed tomographic images of neuroblastoma

    Science.gov (United States)

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Boag, Graham S.

    2004-05-01

    Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, fibrosis, and normal tissue are often intermixed. Rather than attempt to separate these tissue types into distinct regions, we propose to explore methods to delineate the normal structures expected in abdominal CT images, remove them from further consideration, and examine the remaining parts of the images for the tumor mass. We explore the use of fuzzy connectivity for this purpose. Expert knowledge provided by the radiologist in the form of the expected structures and their shapes, HU values, and radiological characteristics are also incorporated in the segmentation algorithm. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative assessment of the response to chemotherapy and in the planning of delayed surgery for resection of the tumor. The performance of the algorithm is evaluated using cases acquired from the Alberta Children's Hospital.

  7. Coronal mass ejection kinematics deduced from white light (Solar Mass Ejection Imager) and radio (Wind/WAVES) observations

    Science.gov (United States)

    Reiner, M. J.; Jackson, B. V.; Webb, D. F.; Mizuno, D. R.; Kaiser, M. L.; Bougeret, J.-L.

    2005-09-01

    White-light and radio observations are combined to deduce the coronal and interplanetary kinematics of a fast coronal mass ejection (CME) that was ejected from the Sun at about 1700 UT on 2 November 2003. The CME, which was associated with an X8.3 solar flare from W56°, was observed by the Mauna Loa and Solar and Heliospheric Observatory (SOHO) Large-Angle Spectrometric Coronograph (LASCO) coronagraphs to 14 R⊙. The measured plane-of-sky speed of the LASCO CME was 2600 km s-1. To deduce the kinematics of this CME, we use the plane-of-sky white light observations from both the Solar Mass Ejection Imager (SMEI) all-sky camera on board the Coriolis spacecraft and the SOHO/LASCO coronagraph, as well as the frequency drift rate of the low-frequency radio data and the results of the radio direction-finding analysis from the WAVES experiment on the Wind spacecraft. In agreement with the in situ observations for this event, we find that both the white light and radio observations indicate that the CME must have decelerated significantly beginning near the Sun and continuing well into the interplanetary medium. More specifically, by requiring self-consistency of all the available remote and in situ data, together with a simple, but not unreasonable, assumption about the general characteristic of the CME deceleration, we were able to deduce the radial speed and distance time profiles for this CME as it propagated from the Sun to 1 AU. The technique presented here, which is applicable to mutual SMEI/WAVES CME events, is expected to provide a more complete description and better quantitative understanding of how CMEs propagate through interplanetary space, as well as how the radio emissions, generated by propagating CME/shocks, relate to the shock and CME. This understanding can potentially lead to more accurate predictions for the onset times of space weather events, such as those that were observed during this unique period of intense solar activity.

  8. Characterization of Breast Masses Using a New Method of Ultrasound Contrast Agent Imaging in 3D Mapping of Vascular Anomalies

    National Research Council Canada - National Science Library

    LeCarpentier, Gerald

    2002-01-01

    .... The purpose of this work is to develop an innovative dual-transducer method to control the destruction and imaging of ultrasound contrast during 3D ultrasound scanning of suspicious breast masses...

  9. Automated correlation and classification of secondary ion mass spectrometry images using a k-means cluster method.

    Science.gov (United States)

    Konicek, Andrew R; Lefman, Jonathan; Szakal, Christopher

    2012-08-07

    We present a novel method for correlating and classifying ion-specific time-of-flight secondary ion mass spectrometry (ToF-SIMS) images within a multispectral dataset by grouping images with similar pixel intensity distributions. Binary centroid images are created by employing a k-means-based custom algorithm. Centroid images are compared to grayscale SIMS images using a newly developed correlation method that assigns the SIMS images to classes that have similar spatial (rather than spectral) patterns. Image features of both large and small spatial extent are identified without the need for image pre-processing, such as normalization or fixed-range mass-binning. A subsequent classification step tracks the class assignment of SIMS images over multiple iterations of increasing n classes per iteration, providing information about groups of images that have similar chemistry. Details are discussed while presenting data acquired with ToF-SIMS on a model sample of laser-printed inks. This approach can lead to the identification of distinct ion-specific chemistries for mass spectral imaging by ToF-SIMS, as well as matrix-assisted laser desorption ionization (MALDI), and desorption electrospray ionization (DESI).

  10. Progress and Potential of Imaging Mass Spectrometry Applied to Biomarker Discovery.

    Science.gov (United States)

    Quanico, Jusal; Franck, Julien; Wisztorski, Maxence; Salzet, Michel; Fournier, Isabelle

    2017-01-01

    Mapping provides a direct means to assess the impact of protein biomarkers and puts into context their relevance in the type of cancer being examined. To this end, mass spectrometry imaging (MSI) was developed to provide the needed spatial information which is missing in traditional liquid-based mass spectrometric proteomics approaches. Aptly described as a "molecular histology" technique, MSI gives an additional dimension in characterizing tumor biopsies, allowing for mapping of hundreds of molecules in a single analysis. A decade of developments focused on improving and standardizing MSI so that the technique can be translated into the clinical setting. This review describes the progress made in addressing the technological development that allows to bridge local protein detection by MSI to its identification and to illustrate its potential in studying various aspects of cancer biomarker discovery.

  11. MALDI TOF imaging mass spectrometry in clinical pathology: a valuable tool for cancer diagnostics (review).

    Science.gov (United States)

    Kriegsmann, Jörg; Kriegsmann, Mark; Casadonte, Rita

    2015-03-01

    Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) imaging mass spectrometry (IMS) is an evolving technique in cancer diagnostics and combines the advantages of mass spectrometry (proteomics), detection of numerous molecules, and spatial resolution in histological tissue sections and cytological preparations. This method allows the detection of proteins, peptides, lipids, carbohydrates or glycoconjugates and small molecules.Formalin-fixed paraffin-embedded tissue can also be investigated by IMS, thus, this method seems to be an ideal tool for cancer diagnostics and biomarker discovery. It may add information to the identification of tumor margins and tumor heterogeneity. The technique allows tumor typing, especially identification of the tumor of origin in metastatic tissue, as well as grading and may provide prognostic information. IMS is a valuable method for the identification of biomarkers and can complement histology, immunohistology and molecular pathology in various fields of histopathological diagnostics, especially with regard to identification and grading of tumors.

  12. MRI imaging of fetal neck masses with airway compromise: utility in delivery planning

    Energy Technology Data Exchange (ETDEWEB)

    Kathary, N.; Bulas, D.I. [Dept. of Radiology, Children' s National Medical Center, Washington, DC (United States); Newman, K.D. [Dept. of Surgery, Children' s National Medical Center, Washington, DC (United States); Schonberg, R.L. [Dept. of Medical Genetics, Children' s National Medical Center, Washington, DC (United States)

    2001-10-01

    We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)

  13. MRI imaging of fetal neck masses with airway compromise: utility in delivery planning

    International Nuclear Information System (INIS)

    Kathary, N.; Bulas, D.I.; Newman, K.D.; Schonberg, R.L.

    2001-01-01

    We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)

  14. Visualizing fungal metabolites during mycoparasitic interaction by MALDI mass spectrometry imaging

    Science.gov (United States)

    Holzlechner, Matthias; Reitschmidt, Sonja; Gruber, Sabine; Zeilinger, Susanne

    2016-01-01

    Studying microbial interactions by MALDI mass spectrometry imaging (MSI) directly from growing media is a difficult task if high sensitivity is demanded. We present a quick and robust sample preparation strategy for growing fungi (Trichoderma atroviride, Rhizoctonia solani) on glass slides to establish a miniaturized confrontation assay. By this we were able to visualize metabolite distributions by MALDI MSI after matrix deposition with a home‐built sublimation device and thorough recrystallization. We present for the first time MALDI MSI data for secondary metabolite release during active mycoparasitism. PMID:26959280

  15. Utilizing mass spectrometry imaging to map the thyroid hormones triiodothyronine and thyroxine in Xenopus tropicalis tadpoles.

    Science.gov (United States)

    Goto-Inoue, Naoko; Sato, Tomohiko; Morisasa, Mizuki; Kashiwagi, Akihiko; Kashiwagi, Keiko; Sugiura, Yuki; Sugiyama, Eiji; Suematsu, Makoto; Mori, Tsukasa

    2018-02-01

    Thyroid hormones are not only responsible for thermogenesis and energy metabolism in animals, but also have an important role in cell differentiation and development. Amphibian metamorphosis provides an excellent model for studying the remodeling of the body. This metamorphic organ remodeling is induced by thyroid hormones, and a larval body is thus converted into an adult one. The matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry (MS) imaging technology is expected to be a suitable tool for investigating small bioreactive molecules. The present study describes the distribution of the thyroid hormones, i.e., triiodothyronine (T3) and thyroxine (T4) and their inactive form reverse T3 (rT3) in Xenopus tropicalis tadpoles using two different types of imaging techniques, MS/MS and Fourier transform (FT)-MS imaging. As a result of MS/MS imaging, we demonstrated that T3 was mainly distributed in the gills. T4 was faintly localized in the eyes, inner gills, and intestine during metamorphosis. The intensity of T3 in the gills and the intensity of T4 in the body fluids were increased during metamorphosis. Moreover, the localization of the inactive form rT3 was demonstrated to be separate from T3, namely in the intestine and muscles. In addition, FT-MS imaging could utilize simultaneous imaging including thyroid hormone. This is the first report to demonstrate the molecular distribution of thyroid hormones themselves and to discriminate T3, T4, and rT3 in animal tissues.

  16. Progression of Treated versus Untreated Liver Imaging Reporting and Data System Category 4 Masses after Transcatheter Arterial Embolization Therapy.

    Science.gov (United States)

    Ronald, James; Gupta, Rajan T; Marin, Daniele; Wang, Qi; Durocher, Nicholas S; Suhocki, Paul V; Kim, Charles Y

    2018-05-01

    To compare outcomes of treated vs untreated Liver Imaging Reporting and Data System category 4 (LR-4) masses after transcatheter arterial embolization. In 167 patients undergoing embolization for HCC from January 2005 to December 2012, LR-4 masses were retrospectively identified on CT and MR imaging examinations performed before embolization. In 149 patients undergoing embolization from January 2013 to December 2016, masses prospectively classified as LR-4 were identified. In total, there were 81 LR-4 masses in 62 patients (16 women; mean age 62 y; range 29-83 y). Procedures were reviewed to determine whether LR-4 masses were within or outside the liver volume that received embolization during treatment of dominant masses. Time to progression to LR-5 and by modified Response Evaluation Criteria in Solid Tumors (mRECIST) was estimated for treated vs untreated LR-4 masses using the Kaplan-Meier method and compared using the log rank test. LR-4 masses averaged 1.8 cm; 88%, 60%, 14%, and 14% demonstrated arterial phase hyperenhancement, washout, a capsule, and growth. Of LR-4 masses, 62 were within the liver volume that received embolization and considered treated, and 19 were outside and considered untreated. Response rates according to mRECIST were 37% vs 21% for treated vs untreated masses (P = .27). The 6- and 12-month rates of progression to LR-5 were 7% and 26% for treated masses vs 27% and 75% for untreated masses (P = .001). According to mRECIST, 7% and 27% of treated masses progressed vs 30% and 65% of untreated masses (P = .001). LR-4 masses that receive embolization in the setting of dominant masses elsewhere show lower rates of progression compared with untreated masses. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  17. Investigating the provenance of un-dyed spun cotton fibre using multi-isotope profiles and chemometric analysis.

    Science.gov (United States)

    Daéid, Niamh Nic; Meier-Augenstein, Wolfram; Kemp, Helen F

    2011-07-15

    The analysis of un-dyed spun cotton fibres can be challenging within a forensic science context where discrimination of one fibre from another is of importance. Conventional microscopic and chemical analysis of these fibres is generally unsuccessful because of their similar morphology. In this work we have explored the potential of isotope ratio mass spectrometry (IRMS) as a tool for spun cotton fibre analysis in an attempt to reveal any discriminatory information available. Seven different batches of un-dyed spun cotton fibre from four different countries were analysed. A combination of the hydrogen and oxygen isotopic data facilitated the correct association of the samples, demonstrating, for the first time, the applicability of IRMS to fibre analysis in this way. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Estimating Mass Properties of Dinosaurs Using Laser Imaging and 3D Computer Modelling

    Science.gov (United States)

    Bates, Karl T.; Manning, Phillip L.; Hodgetts, David; Sellers, William I.

    2009-01-01

    Body mass reconstructions of extinct vertebrates are most robust when complete to near-complete skeletons allow the reconstruction of either physical or digital models. Digital models are most efficient in terms of time and cost, and provide the facility to infinitely modify model properties non-destructively, such that sensitivity analyses can be conducted to quantify the effect of the many unknown parameters involved in reconstructions of extinct animals. In this study we use laser scanning (LiDAR) and computer modelling methods to create a range of 3D mass models of five specimens of non-avian dinosaur; two near-complete specimens of Tyrannosaurus rex, the most complete specimens of Acrocanthosaurus atokensis and Strutiomimum sedens, and a near-complete skeleton of a sub-adult Edmontosaurus annectens. LiDAR scanning allows a full mounted skeleton to be imaged resulting in a detailed 3D model in which each bone retains its spatial position and articulation. This provides a high resolution skeletal framework around which the body cavity and internal organs such as lungs and air sacs can be reconstructed. This has allowed calculation of body segment masses, centres of mass and moments or inertia for each animal. However, any soft tissue reconstruction of an extinct taxon inevitably represents a best estimate model with an unknown level of accuracy. We have therefore conducted an extensive sensitivity analysis in which the volumes of body segments and respiratory organs were varied in an attempt to constrain the likely maximum plausible range of mass parameters for each animal. Our results provide wide ranges in actual mass and inertial values, emphasizing the high level of uncertainty inevitable in such reconstructions. However, our sensitivity analysis consistently places the centre of mass well below and in front of hip joint in each animal, regardless of the chosen combination of body and respiratory structure volumes. These results emphasize that future

  19. Estimating mass properties of dinosaurs using laser imaging and 3D computer modelling.

    Directory of Open Access Journals (Sweden)

    Karl T Bates

    Full Text Available Body mass reconstructions of extinct vertebrates are most robust when complete to near-complete skeletons allow the reconstruction of either physical or digital models. Digital models are most efficient in terms of time and cost, and provide the facility to infinitely modify model properties non-destructively, such that sensitivity analyses can be conducted to quantify the effect of the many unknown parameters involved in reconstructions of extinct animals. In this study we use laser scanning (LiDAR and computer modelling methods to create a range of 3D mass models of five specimens of non-avian dinosaur; two near-complete specimens of Tyrannosaurus rex, the most complete specimens of Acrocanthosaurus atokensis and Strutiomimum sedens, and a near-complete skeleton of a sub-adult Edmontosaurus annectens. LiDAR scanning allows a full mounted skeleton to be imaged resulting in a detailed 3D model in which each bone retains its spatial position and articulation. This provides a high resolution skeletal framework around which the body cavity and internal organs such as lungs and air sacs can be reconstructed. This has allowed calculation of body segment masses, centres of mass and moments or inertia for each animal. However, any soft tissue reconstruction of an extinct taxon inevitably represents a best estimate model with an unknown level of accuracy. We have therefore conducted an extensive sensitivity analysis in which the volumes of body segments and respiratory organs were varied in an attempt to constrain the likely maximum plausible range of mass parameters for each animal. Our results provide wide ranges in actual mass and inertial values, emphasizing the high level of uncertainty inevitable in such reconstructions. However, our sensitivity analysis consistently places the centre of mass well below and in front of hip joint in each animal, regardless of the chosen combination of body and respiratory structure volumes. These results emphasize

  20. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    Science.gov (United States)

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  1. Female body dissatisfaction after exposure to overweight and thin media images : The role of body mass index and neuroticism

    NARCIS (Netherlands)

    Dalley, Simon E.; Buunk, Abraham P.; Umit, Turul

    Exposure to thin media images is thought to play a significant role in the development of body image dissatisfaction (BID) amongst females. In this study we examined whether individual differences in body mass index (BMI) and neuroticism can make females more vulnerable to BID upon exposure to

  2. Imaging mass spectrometry (IMS) of cortical lipids from preclinical to severe stages of Alzheimer's disease.

    Science.gov (United States)

    Gónzalez de San Román, E; Manuel, I; Giralt, M T; Ferrer, I; Rodríguez-Puertas, R

    2017-09-01

    Alzheimer's disease (AD) is a progressive neurodegenerative disease affecting millions of patients worldwide. Previous studies have demonstrated alterations in the lipid composition of lipid extracts from plasma and brain samples of AD patients. However, there is no consensus regarding the qualitative and quantitative changes of lipids in brains from AD patients. In addition, the recent developments in imaging mass spectrometry methods are leading to a new stage in the in situ analysis of lipid species in brain tissue slices from human postmortem samples. The present study uses the matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS), permitting the direct anatomical analysis of lipids in postmortem brain sections from AD patients, which are compared with the intensity of the lipid signal in samples from matched subjects with no neurological diseases. The frontal cortex samples from AD patients were classified in three groups based on Braak's histochemical criteria, ranging from non-cognitively impaired patients to those severely affected. The main results indicate a depletion of different sulfatide lipid species from the earliest stages of the disease in both white and gray matter areas of the frontal cortex. Therefore, the decrease in sulfatides in cortical areas could be considered as a marker of the disease, but may also indicate neurochemical modifications related to the pathogenesis of the disease. This article is part of a Special Issue entitled: Membrane Lipid Therapy: Drugs Targeting Biomembranes edited by Pablo V. Escribá. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. MALDI Mass Spectrometry Imaging of N-Linked Glycans in Cancer Tissues.

    Science.gov (United States)

    Drake, R R; Powers, T W; Jones, E E; Bruner, E; Mehta, A S; Angel, P M

    2017-01-01

    Glycosylated proteins account for a majority of the posttranslation modifications of cell surface, secreted, and circulating proteins. Within the tumor microenvironment, the presence of immune cells, extracellular matrix proteins, cell surface receptors, and interactions between stroma and tumor cells are all processes mediated by glycan binding and recognition reactions. Changes in glycosylation during tumorigenesis are well documented to occur and affect all of these associated adhesion and regulatory functions. A MALDI imaging mass spectrometry (MALDI-IMS) workflow for profiling N-linked glycan distributions in fresh/frozen tissues and formalin-fixed paraffin-embedded tissues has recently been developed. The key to the approach is the application of a molecular coating of peptide-N-glycosidase to tissues, an enzyme that cleaves asparagine-linked glycans from their protein carrier. The released N-linked glycans can then be analyzed by MALDI-IMS directly on tissue. Generally 40 or more individual glycan structures are routinely detected, and when combined with histopathology localizations, tumor-specific glycans are readily grouped relative to nontumor regions and other structural features. This technique is a recent development and new approach in glycobiology and mass spectrometry imaging research methodology; thus, potential uses such as tumor-specific glycan biomarker panels and other applications are discussed. © 2017 Elsevier Inc. All rights reserved.

  4. An accessible, scalable ecosystem for enabling and sharing diverse mass spectrometry imaging analyses.

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, CR; Ruebel, O; Bowen, BP

    2016-01-01

    Mass spectrometry imaging (MSI) is used in an increasing number of biological applications. Typical MSI datasets contain unique, high-resolution mass spectra from tens of thousands of spatial locations, resulting in raw data sizes of tens of gigabytes per sample. In this paper, we review technical progress that is enabling new biological applications and that is driving an increase in the complexity and size of MSI data. Handling such data often requires specialized computational infrastructure, software, and expertise. OpenMSI, our recently described platform, makes it easy to explore and share MSI datasets via the web - even when larger than 50 GB. Here we describe the integration of OpenMSI with IPython notebooks for transparent, sharable, and replicable MSI research. An advantage of this approach is that users do not have to share raw data along with analyses; instead, data is retrieved via OpenMSI's web API. The IPython notebook interface provides a low-barrier entry point for data manipulation that is accessible for scientists without extensive computational training. Via these notebooks, analyses can be easily shared without requiring any data movement. We provide example notebooks for several common MSI analysis types including data normalization, plotting, clustering, and classification, and image registration.

  5. Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry for the Investigation of Proteins and Peptides

    Science.gov (United States)

    Burnum, Kristin E.; Frappier, Sara L.; Caprioli, Richard M.

    2008-07-01

    Mass spectrometry (MS) is an excellent technology for molecular imaging because of its high data dimensionality. MS can monitor thousands of individual molecular data channels measured as mass-to-charge (m/z). We describe the use of matrix-assisted laser desorption/ionization (MALDI) MS for the image analysis of proteins, peptides, lipids, drugs, and metabolites in tissues. We discuss the basic instrumentation and sample preparation methods needed to produce high-resolution images and high image reproducibility. Matrix-addition protocols are briefly discussed along with normal operating procedures, and selected biological and medical applications of MALDI imaging MS are described. We give examples of both two- and three-dimensional imaging, including normal mouse embryo implantation, sperm maturation in mouse epididymis, protein distributions in brain sections, protein alterations as a result of drug administration, and protein changes in brain due to neurodegeneration and tumor formation. Advantages of this technology and future challenges for its improvement are discussed.

  6. Aspects of Quantitation in Mass Spectrometry Imaging Investigated on Cryo-Sections of Spiked Tissue Homogenates.

    Science.gov (United States)

    Hansen, Heidi Toft; Janfelt, Christian

    2016-12-06

    Internal standards have been introduced in quantitative mass spectrometry imaging in order to compensate for differences in intensities throughout an image caused by, for example, difference in ion suppression or analyte extraction efficiency. To test how well the internal standards compensate for differences in tissue types in, for example, whole-body imaging, a set of tissue homogenates of different tissue types (lung, liver, kidney, heart, and brain) from rabbit was spiked to the same concentration with the drug amitriptyline and imaged in the same experiment using isotope labeled amitriptyline as internal standard. The results showed, even after correction with internal standard, significantly lower intensities from brain and to some extent also lung tissue, differences which may be ascribed to binding of the drug to proteins or lipids as known from traditional bioanalysis. The differences, which for these results range approximately within a factor of 3 (but for other compounds in other tissues could be higher), underscore the importance of preparing the standard curve in the same matrix as the unknown sample whenever possible. In, for example, whole-body imaging where a diversity of tissue types are present, this variation across tissue types will therefore add to the overall uncertainty in quantitation. The tissue homogenates were also used in a characterization of various phenomena in quantitative MSI, such as to study how the signal depends of the thickness of the cryo-section, and to assess the accuracy of calibration by droplet deposition. For experiments on liver tissue, calibration by spiked tissue homogenates and droplet deposition was found to provide highly similar results and in both cases linearity with R 2 values of 0.99. In the process, a new method was developed for preparation of standard curves of spiked tissue homogenates, based on the drilling of holes in a block of frozen liver homogenate, providing easy cryo-slicing and good quantitative

  7. Prognostic Metabolite Biomarkers for Soft Tissue Sarcomas Discovered by Mass Spectrometry Imaging

    Science.gov (United States)

    Lou, Sha; Balluff, Benjamin; Cleven, Arjen H. G.; Bovée, Judith V. M. G.; McDonnell, Liam A.

    2017-02-01

    Metabolites can be an important read-out of disease. The identification and validation of biomarkers in the cancer metabolome that can stratify high-risk patients is one of the main current research aspects. Mass spectrometry has become the technique of choice for metabolomics studies, and mass spectrometry imaging (MSI) enables their visualization in patient tissues. In this study, we used MSI to identify prognostic metabolite biomarkers in high grade sarcomas; 33 high grade sarcoma patients, comprising osteosarcoma, leiomyosarcoma, myxofibrosarcoma, and undifferentiated pleomorphic sarcoma were analyzed. Metabolite MSI data were obtained from sections of fresh frozen tissue specimens with matrix-assisted laser/desorption ionization (MALDI) MSI in negative polarity using 9-aminoarcridine as matrix. Subsequent annotation of tumor regions by expert pathologists resulted in tumor-specific metabolite signatures, which were then tested for association with patient survival. Metabolite signals with significant clinical value were further validated and identified by high mass resolution Fourier transform ion cyclotron resonance (FTICR) MSI. Three metabolite signals were found to correlate with overall survival ( m/z 180.9436 and 241.0118) and metastasis-free survival ( m/z 160.8417). FTICR-MSI identified m/z 241.0118 as inositol cyclic phosphate and m/z 160.8417 as carnitine.

  8. The downfall of TBA-354 - a possible explanation for its neurotoxicity via mass spectrometric imaging.

    Science.gov (United States)

    Ntshangase, Sphamandla; Shobo, Adeola; Kruger, Hendrik G; Asperger, Arndt; Niemeyer, Dagmar; Arvidsson, Per I; Govender, Thavendran; Baijnath, Sooraj

    2017-10-13

    1. TBA-354 was a promising antitubercular compound with activity against both replicating and static Mycobacterium tuberculosis (M.tb), making it the focal point of many clinical trials conducted by the TB Alliance. However, findings from these trials have shown that TBA-354 results in mild signs of reversible neurotoxicity; this left the TB Alliance with no other choice but to stop the research. 2. In this study, mass spectrometric methods were used to evaluate the pharmacokinetics and spatial distribution of TBA-354 in the brain using a validated liquid chromatography tandem-mass spectrometry (LCMS/MS) and mass spectrometric imaging (MSI), respectively. Healthy female Sprague-Dawley rats received intraperitoneal (i.p.) doses of TBA-354 (20 mg/kg bw). 3. The concentrationtime profiles showed a gradual absorption and tissue penetration of TBA-354 reaching the C max at 6 h post dose, followed by a rapid elimination. MSI analysis showed a time-dependent drug distribution, with highest drug concentration mainly in the neocortical regions of the brain. 4. The distribution of TBA-354 provides a possible explanation for the motor dysfunction observed in clinical trials. These results prove the importance of MSI as a potential tool in preclinical evaluations of suspected neurotoxic compounds.

  9. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  10. Imaging Nicotine in Rat Brain Tissue by Use of Nanospray Desorption Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lanekoff, Ingela T.; Thomas, Mathew; Carson, James P.; Smith, Jordan N.; Timchalk, Charles; Laskin, Julia

    2013-01-15

    Imaging mass spectrometry offers simultaneous detection of drugs, drug metabolites and endogenous substances in a single experiment. This is important when evaluating effects of a drug on a complex organ system such as the brain, where there is a need to understand how regional drug distribution impacts function. Nicotine is an addictive drug and its action in the brain is of high interest. Here we use nanospray desorption electrospray ionization, nano-DESI, imaging to discover the localization of nicotine in rat brain tissue after in vivo administration of nicotine. Nano-DESI is a new ambient technique that enables spatially-resolved analysis of tissue samples without special sample pretreatment. We demonstrate high sensitivity of nano-DESI imaging that enables detection of only 0.7 fmole nicotine per pixel in the complex brain matrix. Furthermore, by adding deuterated nicotine to the solvent, we examined how matrix effects, ion suppression, and normalization affect the observed nicotine distribution. Finally, we provide preliminary results suggesting that nicotine localizes to the hippocampal substructure called dentate gyrus.

  11. Quantitative images of metals in plant tissues measured by laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietrich, R.C.; Matusch, A.; Pozebon, D.; Dressler, V.L.

    2008-01-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of toxic and essential elements in thin sections (thickness of 30 or 40 μm) of tobacco plant tissues. Two-dimensional images of Mg, Fe, Mn, Zn, Cu, Cd, Rh, Pt and Pb in leaves, shoots and roots of tobacco were produced. Sections of the plant tissues (fixed onto glass slides) were scanned by a focused beam of a Nd:YAG laser in a laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a quadrupole ICP-MS instrument. Ion intensities of the investigated elements were measured together with 13 C + , 33 S + and 34 S + within the entire plant tissue section. Matrix matching standards (prepared using powder of dried tobacco leaves) were used to constitute calibration curves, whereas the regression coefficient of the attained calibration curves was typically 0.99. The variability of LA-ICP-MS process, sample heterogeneity and water content in the sample were corrected by using 13 C + as internal standard. Quantitative imaging of the selected elements revealed their inhomogeneous distribution in leaves, shoots and roots

  12. Investigating the Lymphatic System by Dual-Color Elemental Mass Spectrometry Imaging

    Directory of Open Access Journals (Sweden)

    Ann-Christin Niehoff

    2017-01-01

    Full Text Available Secondary lymphedema accompanied with strong restrictions in quality of life is still major side effects in cancer therapy. Therefore, dedicated diagnostic tools and further investigation of the lymphatic system are crucial to improve lymphedema therapy. In this pilot study, a method for quantitative analysis of the lymphatic system in a rat model by laser ablation (LA with inductively coupled plasma mass spectrometry imaging (ICP-MSI is presented. As a possible lymph marker, thulium(III(1R,4R,7R,10R-α,α′,α′′,α′′′-tetramethyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (Tm-DOTMA is introduced and compared to the clinically used magnetic resonance imaging contrast agent gadolinium(III2,2′,2′′-(10-((2R,3S-1,3,4-trihydroxybutan-2-yl-1,4,7,10-tetraazacyclododecane-1,4,7-triyltriacetate (Gd-DO3A-butrol. Gadobutrol functioned as standard contrast media in MRI lymphangiography to detect lymphatic flow qualitatively. Thus, Tm-DOTMA was investigated as lymphatic marker to detect lymphatic flow quantitatively. Both contrast agents were successfully used to visualize the lymphatic flow in successive lymph nodes in LA-ICP-MS due to lower limits of detection compared to MRI. Furthermore, the distribution of contrast agents by multicolored imaging showed accumulation in specific areas (sectors of the lymph nodes after application of contrast agents in different areas.

  13. Direct Analyses of Secondary Metabolites by Mass Spectrometry Imaging (MSI) from Sunflower (Helianthus annuus L.) Trichomes.

    Science.gov (United States)

    Brentan Silva, Denise; Aschenbrenner, Anna-Katharina; Lopes, Norberto Peporine; Spring, Otmar

    2017-05-10

    Helianthus annuus (sunflower) displays non-glandular trichomes (NGT), capitate glandular trichomes (CGT), and linear glandular trichomes (LGT), which reveal different chemical compositions and locations in different plant tissues. With matrix-assisted laser desorption/ionization (MALDI) and laser desorption/ionization (LDI) mass spectrometry imaging (MSI) techniques, efficient methods were developed to analyze the tissue distribution of secondary metabolites (flavonoids and sesquiterpenes) and proteins inside of trichomes. Herein, we analyzed sesquiterpene lactones, present in CGT, from leaf transversal sections using the matrix 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA) (mixture 1:1) with sodium ions added to increase the ionization in positive ion mode. The results observed for sesquiterpenes and polymethoxylated flavones from LGT were similar. However, upon desiccation, LGT changed their shape in the ionization source, complicating analyses by MSI mainly after matrix application. An alternative method could be applied to LGT regions by employing LDI (without matrix) in negative ion mode. The polymethoxylated flavones were easily ionized by LDI, producing images with higher resolution, but the sesquiterpenes were not observed in spectra. Thus, the application and viability of MALDI imaging for the analyses of protein and secondary metabolites inside trichomes were confirmed, highlighting the importance of optimization parameters.

  14. Development of high-spatial and high-mass resolution mass spectrometric imaging (MSI) and its application to the study of small metabolites and endogenous molecules of plants

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Ji Hyun [Iowa State Univ., Ames, IA (United States)

    2012-01-01

    High-spatial and high-mass resolution laser desorption ionization (LDI) mass spectrometric (MS) imaging technology was developed for the attainment of MS images of higher quality containing more information on the relevant cellular and molecular biology in unprecedented depth. The distribution of plant metabolites is asymmetric throughout the cells and tissues, and therefore the increase in the spatial resolution was pursued to reveal the localization of plant metabolites at the cellular level by MS imaging. For achieving high-spatial resolution, the laser beam size was reduced by utilizing an optical fiber with small core diameter (25 μm) in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer. Matrix application was greatly improved using oscillating capillary nebulizer. As a result, single cell level spatial resolution of ~ 12 μm was achieved. MS imaging at this high spatial resolution was directly applied to a whole Arabidopsis flower and the substructures of an anther and single pollen grains at the stigma and anther were successfully visualized. MS imaging of high spatial resolution was also demonstrated to the secondary roots of Arabidopsis thaliana and a high degree of localization of detected metabolites was successfully unveiled. This was the first MS imaging on the root for molecular species. MS imaging with high mass resolution was also achieved by utilizing the LTQ-Orbitrap mass spectrometer for the direct identification of the surface metabolites on the Arabidopsis stem and root and differentiation of isobaric ions having the same nominal mass with no need of tandem mass spectrometry (MS/MS). MS imaging at high-spatial and high-mass resolution was also applied to cer1 mutant of the model system Arabidopsis thaliana to demonstrate its usefulness in biological studies and reveal associated metabolite changes in terms of spatial distribution and/or abundances compared to those of wild-type. The spatial

  15. The Black Hole Mass-Bulge Luminosity Relationship for Active Galactic Nuclei From Reverberation Mapping and Hubble Space Telescope Imaging

    DEFF Research Database (Denmark)

    Bentz, Misty C.; Peterson, Bradley M.; Pogge, Richard W.

    2009-01-01

    We investigate the relationship between black hole mass and bulge luminosity for active galactic nuclei (AGNs) with reverberation-based black hole mass measurements and bulge luminosities from two-dimensional decompositions of Hubble Space Telescope host galaxy images. We find that the slope...... of the relationship for AGNs is 0.76-0.85 with an uncertainty of ~0.1, somewhat shallower than the M BH vprop L 1.0±0.1 relationship that has been fit to nearby quiescent galaxies with dynamical black hole mass measurements. This difference is somewhat perplexing, as the AGN black hole masses include an overall...

  16. A LAGRANGIAN GAUSS-NEWTON-KRYLOV SOLVER FOR MASS- AND INTENSITY-PRESERVING DIFFEOMORPHIC IMAGE REGISTRATION.

    Science.gov (United States)

    Mang, Andreas; Ruthotto, Lars

    2017-01-01

    We present an efficient solver for diffeomorphic image registration problems in the framework of Large Deformations Diffeomorphic Metric Mappings (LDDMM). We use an optimal control formulation, in which the velocity field of a hyperbolic PDE needs to be found such that the distance between the final state of the system (the transformed/transported template image) and the observation (the reference image) is minimized. Our solver supports both stationary and non-stationary (i.e., transient or time-dependent) velocity fields. As transformation models, we consider both the transport equation (assuming intensities are preserved during the deformation) and the continuity equation (assuming mass-preservation). We consider the reduced form of the optimal control problem and solve the resulting unconstrained optimization problem using a discretize-then-optimize approach. A key contribution is the elimination of the PDE constraint using a Lagrangian hyperbolic PDE solver. Lagrangian methods rely on the concept of characteristic curves. We approximate these curves using a fourth-order Runge-Kutta method. We also present an efficient algorithm for computing the derivatives of the final state of the system with respect to the velocity field. This allows us to use fast Gauss-Newton based methods. We present quickly converging iterative linear solvers using spectral preconditioners that render the overall optimization efficient and scalable. Our method is embedded into the image registration framework FAIR and, thus, supports the most commonly used similarity measures and regularization functionals. We demonstrate the potential of our new approach using several synthetic and real world test problems with up to 14.7 million degrees of freedom.

  17. Application of digital image processing to a β-gauge for determining mass concentration of suspending particulate matter in atmosphere

    International Nuclear Information System (INIS)

    Gotoh, Takao

    1992-01-01

    A two-dimensional image of the mass concentration of suspending particulate matter (SPM) collected on Millipore filter paper was photographed with Ultrofilm- 3 H. The printed paper image was transformed into a digital image (256 x 256 pixels) with 256 gray levels. Two results were obtained. The averaged values of gray level over all pixels of the digital image was found to correlate with the mass value measured by a β-gauge. The characteristic range of the digital image which was transformed to frequency by two-dimensional fast fourier transformation was found in the low frequency. It was presumed to relate to SPM from anthropogenic sources because the SPMs usually show higher density and smaller particle size than SPMs from natural sources. (author)

  18. From whole-body sections down to cellular level, multiscale imaging of phospholipids by MALDI mass spectrometry.

    Science.gov (United States)

    Chaurand, Pierre; Cornett, Dale S; Angel, Peggi M; Caprioli, Richard M

    2011-02-01

    Significant progress in instrumentation and sample preparation approaches have recently expanded the potential of MALDI imaging mass spectrometry to the analysis of phospholipids and other endogenous metabolites naturally occurring in tissue specimens. Here we explore some of the requirements necessary for the successful analysis and imaging of phospholipids from thin tissue sections of various dimensions by MALDI time-of-flight mass spectrometry. We address methodology issues relative to the imaging of whole-body sections such as those cut from model laboratory animals, sections of intermediate dimensions typically prepared from individual organs, as well as the requirements for imaging areas of interests from these sections at a cellular scale spatial resolution. We also review existing limitations of MALDI imaging MS technology relative to compound identification. Finally, we conclude with a perspective on important issues relative to data exploitation and management that need to be solved to maximize biological understanding of the tissue specimen investigated.

  19. Mass Spectrometry Imaging Shows Cocaine and Methylphenidate Have Opposite Effects on Major Lipids in Drosophila Brain.

    Science.gov (United States)

    Philipsen, Mai H; Phan, Nhu T N; Fletcher, John S; Malmberg, Per; Ewing, Andrew G

    2018-03-20

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the effects of cocaine versus methylphenidate administration on both the localization and abundance of lipids in Drosophila melanogaster brain. A J105 ToF-SIMS with a 40 keV gas cluster primary ion source enabled us to probe molecular ions of biomolecules on the fly with a spatial resolution of ∼3 μm, giving us unique insights into the effect of these drugs on molecular lipids in the nervous system. Significant changes in phospholipid composition were observed in the central brain for both. Principal components image analysis revealed that changes occurred mainly for phosphatidylcholines, phosphatidylethanolamines, and phosphatidylinositols. When the lipid changes caused by cocaine were compared with those induced by methylphenidate, it was shown that these drugs exert opposite effects on the brain lipid structure. We speculate that this might relate to the molecular mechanism of cognition and memory.

  20. Three-dimensional molecular imaging using mass spectrometry and atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wucher, Andreas [Department of Physics, University of Duisburg-Essen, D-47048 Duisburg (Germany)], E-mail: andreas.wucher@uni-due.de; Cheng Juan; Zheng Leiliang; Willingham, David; Winograd, Nicholas [Department of Chemistry, Pennsylvania State University, University Park, PA 16802 (United States)

    2008-12-15

    We combine imaging ToF-SIMS depth profiling and wide area atomic force microscopy to analyze a test structure consisting of a 300 nm trehalose film deposited on a Si substrate and pre-structured by means of a focused 15-keV Ga{sup +} ion beam. Depth profiling is performed using a 40-keV C{sub 60}{sup +} cluster ion beam for erosion and mass spectral data acquisition. A generic protocol for depth axis calibration is described which takes into account both lateral and in-depth variations of the erosion rate. By extrapolation towards zero analyzed lateral area, an 'intrinsic' depth resolution of about 8 nm is found which appears to be characteristic of the cluster-surface interaction process.

  1. MALDI (matrix assisted laser desorption ionization) Imaging Mass Spectrometry (IMS) of skin: Aspects of sample preparation.

    Science.gov (United States)

    de Macedo, Cristiana Santos; Anderson, David M; Schey, Kevin L

    2017-11-01

    MALDI (matrix assisted laser desorption ionization) Imaging Mass Spectrometry (IMS) allows molecular analysis of biological materials making possible the identification and localization of molecules in tissues, and has been applied to address many questions on skin pathophysiology, as well as on studies about drug absorption and metabolism. Sample preparation for MALDI IMS is the most important part of the workflow, comprising specimen collection and preservation, tissue embedding, cryosectioning, washing, and matrix application. These steps must be carefully optimized for specific analytes of interest (lipids, proteins, drugs, etc.), representing a challenge for skin analysis. In this review, critical parameters for MALDI IMS sample preparation of skin samples will be described. In addition, specific applications of MALDI IMS of skin samples will be presented including wound healing, neoplasia, and infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. OUTBURST OF COMET 17P/HOLMES OBSERVED WITH THE SOLAR MASS EJECTION IMAGER

    International Nuclear Information System (INIS)

    Li Jing; Jewitt, David; Clover, John M.; Jackson, Bernard V.

    2011-01-01

    We present time-resolved photometric observations of the Jupiter family comet 17P/Holmes during its dramatic 2007 outburst. The observations, from the orbiting Solar Mass Ejection Imager (SMEI), provide the most complete measure of the whole-coma brightness, free from the effects of instrumental saturation and with a time resolution well matched to the rapid brightening of the comet. The light curve is divided into two distinct parts. A rapid rise between the first SMEI observation on UT 2007 October 24 06h 37m (mid-integration) and UT 2007 October 25 is followed by a slow decline until the last SMEI observation on UT 2008 April 6 22h 16m (mid-integration). We find that the rate of change of the brightness is reasonably well described by a Gaussian function having a central time of UT 2007 October 24.54 ± 0.01 and a full width at half-maximum of 0.44 ± 0.02 days. The maximum rate of brightening occurs some 1.2 days after the onset of activity. At the peak, the scattering cross-section grows at 1070 ± 40 km 2 s -1 while the (model-dependent) mass loss rates inferred from the light curve reach a maximum at 3 x 10 5 kg s -1 . The integrated mass in the coma lies in the range (2-90) x 10 10 kg, corresponding to 0.2%-10% of the nucleus mass, while the kinetic energy of the ejecta is (0.7-30) megatonnes TNT. The particulate coma mass could be contained within a shell on the nucleus of thickness 1-60 m. This is also the approximate distance traveled by conducted heat in the century since the previous outburst of 17P/Holmes. This coincidence is consistent with, but does not prove, the idea that the outburst was triggered by the action of conducted heat, possibly through the crystallization of buried amorphous ice.

  3. Imaging mass spectrometry identifies prognostic ganglioside species in rodent intracranial transplants of glioma and medulloblastoma.

    Directory of Open Access Journals (Sweden)

    Leonardo Ermini

    Full Text Available Matrix-assisted laser desorption ionization (MALDI imaging mass spectrometry (MALDI-MSI allows us to investigate the distribution of lipid molecules within tissues. We used MALDI-MSI to identify prognostic gangliosides in tissue sections of rat intracranial allografts of rat glioma and mouse intracranial xenografts of human medulloblastoma. In the healthy adult rodent brain, GM1 and GD1 were the main types of glycolipids. Both gangliosides were absent in both intracranial transplants. The ganglioside GM3 was not present in the healthy adult brain but was highly expressed in rat glioma allografts. In combination with tandem mass spectrometry GM3 (d18:1/C24:0 was identified as the most abundant ganglioside species in the glioma allotransplant. By contrast, mouse xenografts of human medulloblastoma were characterized by prominent expression of the ganglioside GM2 (d18:0/C18:0. Together, these data demonstrate that tissue-based MALDI-MSI of gangliosides is able to discriminate between different brain tumors and may be a useful clinical tool for their classification and grading.

  4. Exquisite Nova Light Curves from the Solar Mass Ejection Imager (SMEI)

    Science.gov (United States)

    Hounsell, R.; Bode, M. F.; Hick, P. P.; Buffington, A.; Jackson, B. V.; Clover, J. M.; Shafter, A. W.; Darnley, M. J.; Mawson, N. R.; Steele, I. A.; Evans, A.; Eyres, S. P. S.; O'Brien, T. J.

    2010-11-01

    We present light curves of three classical novae (CNe; KT Eridani, V598 Puppis, V1280 Scorpii) and one recurrent nova (RS Ophiuchi) derived from data obtained by the Solar Mass Ejection Imager (SMEI) on board the Coriolis satellite. SMEI provides near complete skymap coverage with precision visible-light photometry at 102 minute cadence. The light curves derived from these skymaps offer unprecedented temporal resolution around, and especially before, maximum light, a phase of the eruption normally not covered by ground-based observations. They allow us to explore fundamental parameters of individual objects including the epoch of the initial explosion, the reality and duration of any pre-maximum halt (found in all three fast novae in our sample), the presence of secondary maxima, speed of decline of the initial light curve, plus precise timing of the onset of dust formation (in V1280 Sco) leading to estimation of the bolometric luminosity, white dwarf mass, and object distance. For KT Eri, Liverpool Telescope SkyCamT data confirm important features of the SMEI light curve and overall our results add weight to the proposed similarities of this object to recurrent rather than to CNe. In RS Oph, comparison with hard X-ray data from the 2006 outburst implies that the onset of the outburst coincides with extensive high-velocity mass loss. It is also noted that two of the four novae we have detected (V598 Pup and KT Eri) were only discovered by ground-based observers weeks or months after maximum light, yet these novae reached peak magnitudes of 3.46 and 5.42, respectively. This emphasizes the fact that many bright novae per year are still overlooked, particularly those of the very fast speed class. Coupled with its ability to observe novae in detail even when relatively close to the Sun in the sky, we estimate that as many as five novae per year may be detectable by SMEI.

  5. THE CHARA ARRAY ANGULAR DIAMETER OF HR 8799 FAVORS PLANETARY MASSES FOR ITS IMAGED COMPANIONS

    International Nuclear Information System (INIS)

    Baines, Ellyn K.; White, Russel J.; Jones, Jeremy; Boyajian, Tabetha; McAlister, Harold A.; Ten Brummelaar, Theo A.; Turner, Nils H.; Sturmann, Judit; Sturmann, Laszlo; Goldfinger, P. J.; Farrington, Christopher D.; Riedel, Adric R.; Huber, Daniel; Ireland, Michael; Von Braun, Kaspar; Ridgway, Stephen T.

    2012-01-01

    HR 8799 is an hF0 mA5 γ Doradus-, λ Bootis-, Vega-type star best known for hosting four directly imaged candidate planetary companions. Using the CHARA Array interferometer, we measure HR 8799's limb-darkened angular diameter to be 0.342 ± 0.008 mas (an error of only 2%). By combining our measurement with the star's parallax and photometry from the literature, we greatly improve upon previous estimates of its fundamental parameters, including stellar radius (1.44 ± 0.06 R ☉ ), effective temperature (7193 ± 87 K, consistent with F0), luminosity (5.05 ± 0.29 L ☉ ), and the extent of the habitable zone (HZ; 1.62-3.32 AU). These improved stellar properties permit much more precise comparisons with stellar evolutionary models, from which a mass and age can be determined, once the metallicity of the star is known. Considering the observational properties of other λ Bootis stars and the indirect evidence for youth of HR 8799, we argue that the internal abundance, and what we refer to as the effective abundance, is most likely near solar. Finally, using the Yonsei-Yale evolutionary models with uniformly scaled solar-like abundances, we estimate HR 8799's mass and age considering two possibilities: 1.516 +0.038 –0.024 M ☉ and 33 +7 –13.2 Myr if the star is contracting toward the zero-age main sequence or 1.513 +0.023 –0.024 M ☉ and 90 +381 –50 Myr if it is expanding from it. This improved estimate of HR 8799's age with realistic uncertainties provides the best constraints to date on the masses of its orbiting companions, and strongly suggests they are indeed planets. They nevertheless all appear to orbit well outside the HZ of this young star.

  6. MALDI Mass Spectrometry Imaging for Visualizing In Situ Metabolism of Endogenous Metabolites and Dietary Phytochemicals

    Science.gov (United States)

    Fujimura, Yoshinori; Miura, Daisuke

    2014-01-01

    Understanding the spatial distribution of bioactive small molecules is indispensable for elucidating their biological or pharmaceutical roles. Mass spectrometry imaging (MSI) enables determination of the distribution of ionizable molecules present in tissue sections of whole-body or single heterogeneous organ samples by direct ionization and detection. This emerging technique is now widely used for in situ label-free molecular imaging of endogenous or exogenous small molecules. MSI allows the simultaneous visualization of many types of molecules including a parent molecule and its metabolites. Thus, MSI has received much attention as a potential tool for pathological analysis, understanding pharmaceutical mechanisms, and biomarker discovery. On the other hand, several issues regarding the technical limitations of MSI are as of yet still unresolved. In this review, we describe the capabilities of the latest matrix-assisted laser desorption/ionization (MALDI)-MSI technology for visualizing in situ metabolism of endogenous metabolites or dietary phytochemicals (food factors), and also discuss the technical problems and new challenges, including MALDI matrix selection and metabolite identification, that need to be addressed for effective and widespread application of MSI in the diverse fields of biological, biomedical, and nutraceutical (food functionality) research. PMID:24957029

  7. Quantification of low molecular weight compounds by MALDI imaging mass spectrometry - A tutorial review.

    Science.gov (United States)

    Rzagalinski, Ignacy; Volmer, Dietrich A

    2017-07-01

    Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry imaging (MSI) permits label-free in situ analysis of chemical compounds directly from the surface of two-dimensional biological tissue slices. It links qualitative molecular information of compounds to their spatial coordinates and distribution within the investigated tissue. MALDI-MSI can also provide the quantitative amounts of target compounds in the tissue, if proper calibration techniques are performed. Obviously, as the target molecules are embedded within the biological tissue environment and analysis must be performed at their precise locations, there is no possibility for extensive sample clean-up routines or chromatographic separations as usually performed with homogenized biological materials; ion suppression phenomena therefore become a critical side effect of MALDI-MSI. Absolute quantification by MALDI-MSI should provide an accurate value of the concentration/amount of the compound of interest in relatively small, well-defined region of interest of the examined tissue, ideally in a single pixel. This goal is extremely challenging and will not only depend on the technical possibilities and limitations of the MSI instrument hardware, but equally on the chosen calibration/standardization strategy. These strategies are the main focus of this article and are discussed and contrasted in detail in this tutorial review. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Assessment of bone mass by image analysis of metacarpal bone roentgenograms

    International Nuclear Information System (INIS)

    Hayashi, Yasufumi; Yamamoto, Kichizo; Fukunaga, Masao; Ishibashi, Toshinobu; Takahashi, Kichiya; Nishii, Yasuho.

    1990-01-01

    A digital image processing (DIP) method for assessing bone mass was developed on the basis of image analysis of roentgenograms. Linearity between DIP values and the actual calcium carbonate content was scarcely affected even if roentgenograms were made with bone phantoms placed in different depths of water or by altering the voltage of X-ray generation. In clinical studies, coefficients of variation (CV) for various measurements were lower than 2.4%. When the correlation between the DIP values and the bone mineral densities in the distal one-third of the radius, and the 2nd to 4th lumbar vertebrae were investigated in 340 females, there were good positive correlations of r=0.799, and r=0.611, respectively (p<0.001). The DIP value was significantly lower in patients showing a low Singh index and in those with vertebral fractures than in other subjects. These results suggest that the DIP method provides an index with which to assess the efficacy of treatment and which can be used as a criterion in screening for osteoporosis. (author)

  9. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Balvay, Daniel; Aubert, Emilie; Bazot, Marc; Darai, Emile; Rouzier, Roman; Cuenod, Charles A.

    2012-01-01

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F T ), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F T , Vb, rAUC and lower Ve than benign tumours (P T was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F T and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  10. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Service de Radiologie, Hopital Tenon, Paris (France); Balvay, Daniel [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Aubert, Emilie; Bazot, Marc [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Darai, Emile; Rouzier, Roman [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Gynaecology-Obstetrics, Paris (France); Cuenod, Charles A. [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Department of Radiology, Paris (France)

    2012-04-15

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F{sub T}), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F{sub T}, Vb, rAUC and lower Ve than benign tumours (P < 0.0001, P = 0.0006, P = 0.04 and P = 0.0002, respectively). F{sub T} was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F{sub T} and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  11. MALDI Imaging Mass Spectrometry (MALDI-IMS―Application of Spatial Proteomics for Ovarian Cancer Classification and Diagnosis

    Directory of Open Access Journals (Sweden)

    Johan O. R. Gustafsson

    2011-01-01

    Full Text Available MALDI imaging mass spectrometry (MALDI-IMS allows acquisition of mass data for metabolites, lipids, peptides and proteins directly from tissue sections. IMS is typically performed either as a multiple spot profiling experiment to generate tissue specific mass profiles, or a high resolution imaging experiment where relative spatial abundance for potentially hundreds of analytes across virtually any tissue section can be measured. Crucially, imaging can be achieved without prior knowledge of tissue composition and without the use of antibodies. In effect MALDI-IMS allows generation of molecular data which complement and expand upon the information provided by histology including immuno-histochemistry, making its application valuable to both cancer biomarker research and diagnostics. The current state of MALDI-IMS, key biological applications to ovarian cancer research and practical considerations for analysis of peptides and proteins on ovarian tissue are presented in this review.

  12. OpenMSI: A High-Performance Web-Based Platform for Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rubel, Oliver; Greiner, Annette; Cholia, Shreyas; Louie, Katherine; Bethel, E. Wes; Northen, Trent R.; Bowen, Benjamin P.

    2013-10-02

    Mass spectrometry imaging (MSI) enables researchers to directly probe endogenous molecules directly within the architecture of the biological matrix. Unfortunately, efficient access, management, and analysis of the data generated by MSI approaches remain major challenges to this rapidly developing field. Despite the availability of numerous dedicated file formats and software packages, it is a widely held viewpoint that the biggest challenge is simply opening, sharing, and analyzing a file without loss of information. Here we present OpenMSI, a software framework and platform that addresses these challenges via an advanced, high-performance, extensible file format and Web API for remote data access (http://openmsi.nersc.gov). The OpenMSI file format supports storage of raw MSI data, metadata, and derived analyses in a single, self-describing format based on HDF5 and is supported by a large range of analysis software (e.g., Matlab and R) and programming languages (e.g., C++, Fortran, and Python). Careful optimization of the storage layout of MSI data sets using chunking, compression, and data replication accelerates common, selective data access operations while minimizing data storage requirements and are critical enablers of rapid data I/O. The OpenMSI file format has shown to provide >2000-fold improvement for image access operations, enabling spectrum and image retrieval in less than 0.3 s across the Internet even for 50 GB MSI data sets. To make remote high-performance compute resources accessible for analysis and to facilitate data sharing and collaboration, we describe an easy-to-use yet powerful Web API, enabling fast and convenient access to MSI data, metadata, and derived analysis results stored remotely to facilitate high-performance data analysis and enable implementation of Web based data sharing, visualization, and analysis.

  13. Differential diagnosis of benign and malignant breast masses using diffusion-weighted magnetic resonance imaging.

    Science.gov (United States)

    Min, Qinghua; Shao, Kangwei; Zhai, Lulan; Liu, Wei; Zhu, Caisong; Yuan, Lixin; Yang, Jun

    2015-02-07

    Diffusion-weighted magnetic resonance imaging (DW-MRI) is different from conventional diagnostic methods and has the potential to delineate the microscopic anatomy of a target tissue or organ. The purpose of our study was to evaluate the value of DW-MRI in the diagnosis of benign and malignant breast masses, which would help the clinical surgeon to decide the scope and pattern of operation. A total of 52 female patients with palpable solid breast masses received breast MRI scans using routine sequences, dynamic contrast-enhanced imaging, and diffusion-weighted echo-planar imaging at b values of 400, 600, and 800 s/mm(2), respectively. Two regions of interest (ROIs) were plotted, with a smaller ROI for the highest signal and a larger ROI for the overall lesion. Apparent diffusion coefficient (ADC) values were calculated at three different b values for all detectable lesions and from two different ROIs. The sensitivity, specificity, positive predictive value, and positive likelihood ratio of DW-MRI were determined for comparison with histological results. A total of 49 (49/52, 94.2%) lesions were detected using DW-MRI, including 20 benign lesions (two lesions detected in the same patient) and 29 malignant lesions. Benign lesion had a higher mean ADC value than their malignant counterparts, regardless of b value. According to the receiver operating characteristic (ROC) curve, the smaller-range ROI was more effective in differentiation between benign and malignant lesions. The area under the ROC curve was the largest at a b value of 800 s/mm(2). With a threshold ADC value at 1.23 × 10(-3) mm(2)/s, DW-MRI achieved a sensitivity of 82.8%, specificity of 90.0%, positive predictive value of 92.3%, and positive likelihood ratio of 8.3 for differentiating benign and malignant lesions. DW-MRI is an accurate diagnostic tool for differentiation between benign and malignant breast lesions, with an optimal b value of 800 s/mm(2). A smaller-range ROI focusing on the

  14. Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

    Science.gov (United States)

    Lee, Su Hyun; Chang, Jung Min; Kim, Won Hwa; Bae, Min Sun; Seo, Mirinae; Koo, Hye Ryoung; Chu, A Jung; Gweon, Hye Mi; Cho, Nariya; Moon, Woo Kyung

    2014-10-01

    To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses. This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy. Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy. © RSNA, 2014.

  15. Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

    Energy Technology Data Exchange (ETDEWEB)

    Burnum-Johnson, Kristin E.; Baker, Erin S.; Metz, Thomas O.

    2017-12-01

    Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

  16. A study on the digital image transfer application mass chest X-ray system up-grade

    International Nuclear Information System (INIS)

    Kim, Sun Chil; Park, Jong Sam; Lee, Jon Il

    2003-01-01

    By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must

  17. Laser desorption/ionization mass spectrometry for direct profiling and imaging of small molecules from raw biological materials

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sangwon [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    Matrix-assisted laser desorption/ionization(MALDI) mass spectrometry(MS) has been widely used for analysis of biological molecules, especially macromolecules such as proteins. However, MALDI MS has a problem in small molecule (less than 1 kDa) analysis because of the signal saturation by organic matrixes in the low mass region. In imaging MS (IMS), inhomogeneous surface formation due to the co-crystallization process by organic MALDI matrixes limits the spatial resolution of the mass spectral image. Therefore, to make laser desorption/ionization (LDI) MS more suitable for mass spectral profiling and imaging of small molecules directly from raw biological tissues, LDI MS protocols with various alternative assisting materials were developed and applied to many biological systems of interest. Colloidal graphite was used as a matrix for IMS of small molecules for the first time and methodologies for analyses of small metabolites in rat brain tissues, fruits, and plant tissues were developed. With rat brain tissues, the signal enhancement for cerebroside species by colloidal graphite was observed and images of cerebrosides were successfully generated by IMS. In addition, separation of isobaric lipid ions was performed by imaging tandem MS. Directly from Arabidopsis flowers, flavonoids were successfully profiled and heterogeneous distribution of flavonoids in petals was observed for the first time by graphite-assisted LDI(GALDI) IMS.

  18. Coastal groundwater salinization: Focus on the vertical variability in a multi-layered aquifer through a multi-isotope fingerprinting (Roussillon Basin, France)

    Energy Technology Data Exchange (ETDEWEB)

    Petelet-Giraud, Emmanuelle, E-mail: e.petelet@brgm.fr [BRGM, Avenue C. Guillemin, BP 36009, 45060 Orléans Cedex 02 (France); Négrel, Philippe [BRGM, Avenue C. Guillemin, BP 36009, 45060 Orléans Cedex 02 (France); Aunay, Bertrand [BRGM, Réunion Agency, 5, rue Sainte-Anne, CS 51016, 97404 Saint Denis Cedex (France); Ladouche, Bernard; Bailly-Comte, Vincent [BRGM Montpellier Agency, 1039, rue de Pinville, 34000 Montpellier (France); Guerrot, Catherine; Flehoc, Christine [BRGM, Avenue C. Guillemin, BP 36009, 45060 Orléans Cedex 02 (France); Pezard, Philippe; Lofi, Johanna [Géosciences Montpellier, UMR 5243, Université de Montpellier, cc069, Place Eugène Bataillon, 34095 Montpellier Cedex 05 (France); Dörfliger, Nathalie [BRGM, Avenue C. Guillemin, BP 36009, 45060 Orléans Cedex 02 (France)

    2016-10-01

    ), we discuss the possible future evolution of this aquifer system under global change, as well as the potential management strategies needed to preserve quantitatively and qualitatively this water resource. - Highlights: • Groundwater salinization in a Mediterranean costal aquifer • Multilevel investigation in a multi-layered aquifer with a Westbay (Nova Metrix LLC) • Chemical and multi-isotope fingerprinting of salinization sources and processes • No evidence of present-day seawater intrusion along the vertical profile of BAR1 • Coupling geochemistry and models for a sustainable preservation of coastal aquifer.

  19. Using Multi-Isotope Tracer Methods to Understand the Sources of Nitrate in Aerosols, Fog and River Water in Podocarpus National Forest, Ecuador

    Science.gov (United States)

    Brothers, L. A.; Dominguez, G.; Fabian, P.; Thiemens, M. H.

    2008-12-01

    sulfate and nitrate concentrations in rain and fog water by standard methods to investigate water and nutrient pathways along with data from satellite and ground based remote sensing, observations and numerical models. We hope to pair this with a multi-isotope tracer method and NOAA Hysplit Back trajectories, and satellite imagery for information about the number of fires burning in the region to help identify sources of the high nitrate deposition.

  20. Time‐of‐flight secondary ion mass spectrometry imaging of biological samples with delayed extraction for high mass and high spatial resolutions

    Science.gov (United States)

    Vanbellingen, Quentin P.; Elie, Nicolas; Eller, Michael J.; Della‐Negra, Serge; Touboul, David

    2015-01-01

    Rationale In Time‐of‐Flight Secondary Ion Mass Spectrometry (TOF‐SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF‐SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a mass resolution of several thousand or a sub‐µm lateral resolution, but the combination of both is generally not possible. Methods With a TOF‐SIMS setup, a delayed extraction applied to secondary ions has been studied extensively on rat cerebellum sections in order to compensate for the effect of long primary ion bunches. Results The use of a delayed extraction has been proven to be an efficient solution leading to unique features, i.e. a mass resolution up to 10000 at m/z 385.4 combined with a lateral resolution of about 400 nm. Simulations of ion trajectories confirm the experimental determination of optimal delayed extraction and allow understanding of the behavior of ions as a function of their mass‐to‐charge ratio. Conclusions Although the use of a delayed extraction has been well known for many years and is very popular in MALDI, it is much less used in TOF‐SIMS. Its full characterization now enables secondary ion images to be recorded in a single run with a submicron spatial resolution and with a mass resolution of several thousand. This improvement is very useful when analyzing lipids on tissue sections, or rare, precious, or very small size samples. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. PMID:26395603

  1. Simultaneous imaging of multiple neurotransmitters and neuroactive substances in the brain by desorption electrospray ionization mass spectrometry

    OpenAIRE

    Shariatgorji, Mohammadreza; Strittmatter, Nicole; Nilsson, Anna; Kallbäck, Patrik; Alvarsson, Alexandra; Zhang, Xiaoqun; Vallianatou, Theodosia; Svenningsson, Per; Goodwin, Richard J. A.; Andrén, Per E.

    2016-01-01

    With neurological processes involving multiple neurotransmitters and neuromodulators, it is important to have the ability to directly map and quantify multiple signaling molecules simultaneously in a single analysis. By utilizing a molecular-specific approach, namely desorption electrospray ionization mass spectrometry imaging (DESI-MSI), we demonstrated that the technique can be used to image multiple neurotransmitters and their metabolites (dopamine, dihydroxyphenylacetic acid, 3-methoxytyr...

  2. [Diffusion weighted imaging and perfusion weighted imaging in the differential diagnosis of benign and malignant renal masses on 3.0 T MRI].

    Science.gov (United States)

    Xu, Xiaowen; Wang, Peijun; Ma, Liang; Shao, Zhihong; Zhang, Min

    2015-01-20

    To explore the value of diffusion weighted imaging (DWI) and perfusion weighted imaging (PWI) in identifying benign and malignant renal masses and differentiating the histological types of renal masses. Fifteen healthy volunteers and 46 patients with renal masses proven by pathology, including clear cell carcinomas (n = 18), papillary carcinomas (n = 8), chromophobe carcinomas (n = 7) and angiomyolipomas (n = 13), were examined with DWI and PWI scan at 3.0 T MRI. ANOVA was employed to compare the values of transfer constant (K(trans)), rate constant of backflux (Kep) and extra-vascular extra-cellular space fractional volume (Ve) proceeded by PWI and the value of ADC resulted from DWI between normal kidney and different histological types of renal masses. Receiver operating characteristics (ROC) curve was used to analyze and compare the diagnostic value of the methods of PWI and DWI in differentiating benign and malignant renal masses. The ADC value of normal renal parenchyma was (2.10 ± 0.24) × 10⁻³ mm²/s, which was statistically higher than benign and malignant renal masses (P 0.05).Values of K(trans), Kep and Ve between normal renal parenchyma and different histological types of renal masses had statistical differences.Values of K(trans) and Ve in three histological types of malignant renal masses were statistically higher than those of benign renal masses.Kep value of clear cell carcinoma was significantly higher than that of benign renal masses (P benign and malignant renal masses. The K(trans) of benign and malignant renal masses had the largest AUC (AUC = 0.937) at a threshold of 0.38/min. And there were a sensitivity of 87.9% and a specificity of 85.7%. The AUC of ADC was 0.823, sensitivity 72.7% and specificity 92.9%. The ADC threshold for differentiating benign from malignant masses was 1.40 × 10⁻³ mm²/s; AUC of Ve 0.803, sensitivity 78.8% and specificity 71.4%, a threshold of 0.29/min; Kep showed lower diagnostic value. 3.0 T MRI DWI and PWI

  3. Near Real-Time Photometric Data Processing for the Solar Mass Ejection Imager (SMEI)

    Science.gov (United States)

    Hick, P. P.; Buffington, A.; Jackson, B. V.

    2004-12-01

    The Solar Mass Ejection Imager (SMEI) records a photometric white-light response of the interplanetary medium from Earth over most of the sky in near real time. In the first two years of operation the instrument has recorded the inner heliospheric response to several hundred CMEs, including the May 28, 2003 and the October 28, 2003 halo CMEs. In this preliminary work we present the techniques required to process the SMEI data from the time the raw CCD images become available to their final assembly in photometrically accurate maps of the sky brightness relative to a long-term time base. Processing of the SMEI data includes integration of new data into the SMEI data base; a conditioning program that removes from the raw CCD images an electronic offset ("pedestal") and a temperature-dependent dark current pattern; an "indexing" program that places these CCD images onto a high-resolution sidereal grid using known spacecraft pointing information. At this "indexing" stage further conditioning removes the bulk of the the effects of high-energy-particle hits ("cosmic rays"), space debris inside the field of view, and pixels with a sudden state change ("flipper pixels"). Once the high-resolution grid is produced, it is reformatted to a lower-resolution set of sidereal maps of sky brightness. From these sidereal maps we remove bright stars, background stars, and a zodiacal cloud model (their brightnesses are retained as additional data products). The final maps can be represented in any convenient sky coordinate system. Common formats are Sun-centered Hammer-Aitoff or "fisheye" maps. Time series at selected locations on these maps are extracted and processed further to remove aurorae, variable stars and other unwanted signals. These time series (with a long-term base removed) are used in 3D tomographic reconstructions. The data processing is distributed over multiple PCs running Linux, and, runs as much as possible automatically using recurring batch jobs ('cronjobs'). The

  4. Canine histiocytic sarcoma presenting as a target lesion on brain magnetic resonance imaging and as a solitary pulmonary mass.

    Science.gov (United States)

    Hicks, Jill; Barber, Renee; Childs, Bronwen; Kirejczyk, Shannon Gm; Uhl, Elizabeth W

    2017-04-17

    A 6-year-old spayed female miniature schnauzer presented with generalized seizures and progressive multifocal intracranial neurologic disease. Thoracic radiographs and computed tomography (CT) revealed a large solitary pulmonary mass within the right cranial lung lobe. On brain magnetic resonance imaging (MRI), a solitary intraparenchymal mass within the left piriform lobe had a "target" appearance on both pre- and postcontrast sequences. Cerebrospinal fluid was unremarkable and histopathology indicated both masses represented histiocytic sarcoma. This case represents an uncommonly reported MRI appearance of histiocytic sarcoma in the canine brain and a large, solitary-appearing pulmonary histiocytic sarcoma in the same dog. © 2017 American College of Veterinary Radiology.

  5. Cryo-sectioning of mice for whole-body imaging of drugs and metabolites with desorption electrospray ionization mass spectrometry imaging - a simplified approach.

    Science.gov (United States)

    Okutan, Seda; Hansen, Harald S; Janfelt, Christian

    2016-06-01

    A method is presented for whole-body imaging of drugs and metabolites in mice with desorption electrospray ionization mass spectrometry imaging (DESI-MSI). Unlike most previous approaches to whole-body imaging which are based on cryo-sectioning using a cryo-macrotome, the presented approach is based on use of the cryo-microtome which is found in any histology lab. The tissue sections are collected on tape which is analyzed directly by DESI-MSI. The method is demonstrated on mice which have been dosed intraperitoneally with the antidepressive drug amitriptyline. By combining full-scan detection with the more selective and sensitive MS/MS detection, a number of endogenous compounds (lipids) were imaged simultaneously with the drug and one of its metabolites. The sensitivity of this approach allowed for imaging of drug and the metabolite in a mouse dosed with 2.7 mg amitriptyline per kg bodyweight which is comparable to the normal prescribed human dose. The simultaneous imaging of endogenous and exogenous compounds facilitates registration of the drug images to certain organs in the body by colored-overlay of the two types of images. The method represents a relatively low-cost approach to simple, sensitive and highly selective whole-body imaging in drug distribution and metabolism studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Modeling observations of solar coronal mass ejections with heliospheric imagers verified with the Heliophysics System Observatory.

    Science.gov (United States)

    Möstl, C; Isavnin, A; Boakes, P D; Kilpua, E K J; Davies, J A; Harrison, R A; Barnes, D; Krupar, V; Eastwood, J P; Good, S W; Forsyth, R J; Bothmer, V; Reiss, M A; Amerstorfer, T; Winslow, R M; Anderson, B J; Philpott, L C; Rodriguez, L; Rouillard, A P; Gallagher, P; Nieves-Chinchilla, T; Zhang, T L

    2017-07-01

    We present an advance toward accurately predicting the arrivals of coronal mass ejections (CMEs) at the terrestrial planets, including Earth. For the first time, we are able to assess a CME prediction model using data over two thirds of a solar cycle of observations with the Heliophysics System Observatory. We validate modeling results of 1337 CMEs observed with the Solar Terrestrial Relations Observatory (STEREO) heliospheric imagers (HI) (science data) from 8 years of observations by five in situ observing spacecraft. We use the self-similar expansion model for CME fronts assuming 60° longitudinal width, constant speed, and constant propagation direction. With these assumptions we find that 23%-35% of all CMEs that were predicted to hit a certain spacecraft lead to clear in situ signatures, so that for one correct prediction, two to three false alarms would have been issued. In addition, we find that the prediction accuracy does not degrade with the HI longitudinal separation from Earth. Predicted arrival times are on average within 2.6 ± 16.6 h difference of the in situ arrival time, similar to analytical and numerical modeling, and a true skill statistic of 0.21. We also discuss various factors that may improve the accuracy of space weather forecasting using wide-angle heliospheric imager observations. These results form a first-order approximated baseline of the prediction accuracy that is possible with HI and other methods used for data by an operational space weather mission at the Sun-Earth L5 point.

  7. Influence of thresholding in mass and entropy dimension of 3-D soil images

    Directory of Open Access Journals (Sweden)

    A. M. Tarquis

    2008-11-01

    Full Text Available With the advent of modern non-destructive tomography techniques, there have been many attempts to analyze 3-D pore space features mainly concentrating on soil structure. This analysis opens a challenging opportunity to develop techniques for quantifying and describe pore space properties, one of them being fractal analysis.

    Undisturbed soil samples were collected from four horizons of Brazilian soil and 3-D images at 45 μm resolution. Four different threshold criteria were used to transform computed tomography (CT grey-scale imagery into binary imagery (pore/solid to estimate their mass fractal dimension (Dm and entropy dimension (D1. Each threshold criteria had a direct influence on the porosity obtained, varying from 8 to 24% in one of the samples, and on the fractal dimensions. Linear scaling was observed over all the cube sizes, however depending on the range of cube sizes used in the analysis, Dm could vary from 3.00 to 2.20, realizing that the threshold influenced mainly the scaling in the smallest cubes (length of size from 1 to 16 voxels.

    Dm and D1 showed a logarithmic relation with the apparent porosity in the image, however, the increase of both values respect to porosity defined a characteristic feature for each horizon that can be related to soil texture and depth.

  8. Incidental breast masses detected by computed tomography: are any imaging features predictive of malignancy?

    Energy Technology Data Exchange (ETDEWEB)

    Porter, G. [Primrose Breast Care Unit, Derriford Hospital, Plymouth (United Kingdom)], E-mail: Gareth.Porter@phnt.swest.nhs.uk; Steel, J.; Paisley, K.; Watkins, R. [Primrose Breast Care Unit, Derriford Hospital, Plymouth (United Kingdom); Holgate, C. [Department of Histopathology, Derriford Hospital, Plymouth (United Kingdom)

    2009-05-15

    Aim: To review the outcome of further assessment of breast abnormalities detected incidentally by multidetector computed tomography (MDCT) and to determine whether any MDCT imaging features were predictive of malignancy. Material and methods: The outcome of 34 patients referred to the Primrose Breast Care Unit with breast abnormalities detected incidentally using MDCT was prospectively recorded. Women with a known diagnosis of breast cancer were excluded. CT imaging features and histological diagnoses were recorded and the correlation assessed using Fisher's exact test. Results: Of the 34 referred patients a malignant diagnosis was noted in 11 (32%). There were 10 breast malignancies (seven invasive ductal carcinomas, one invasive lobular carcinoma, two metastatic lesions) and one axillary lymphoma. CT features suggestive of breast malignancy were spiculation [6/10 (60%) versus 0/24 (0%) p = 0.0002] and associated axillary lymphadenopathy [3/10 (33%) versus 0/20 (0%) p = 0.030]. Conversely, a well-defined mass was suggestive of benign disease [10/24 (42%) versus 0/10 (0%); p = 0.015]. Associated calcification, ill-definition, heterogeneity, size, and multiplicity of lesions were not useful discriminating CT features. There was a non-significant trend for lesions in involuted breasts to be more frequently malignant than in dense breasts [6/14 (43%) versus 4/20 (20%) p = 0.11]. Conclusion: In the present series there was a significant rate (32%) of malignancy in patients referred to the breast clinic with CT-detected incidental breast lesions. The CT features of spiculation or axillary lymphadenopathy are strongly suggestive of malignancy.

  9. Development of matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) for plant metabolite analysis

    Energy Technology Data Exchange (ETDEWEB)

    Korte, Andrew R [Iowa State Univ., Ames, IA (United States)

    2014-12-01

    This thesis presents efforts to improve the methodology of matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) as a method for analysis of metabolites from plant tissue samples. The first chapter consists of a general introduction to the technique of MALDI-MSI, and the sixth and final chapter provides a brief summary and an outlook on future work.

  10. Batch-processing of imaging or liquid-chromatography mass spectrometry datasets and De Novo sequencing of polyketide siderophores

    Czech Academy of Sciences Publication Activity Database

    Novák, Jiří; Sokolová, Lucie; Lemr, Karel; Pluháček, Tomáš; Palyzová, Andrea; Havlíček, Vladimír

    2017-01-01

    Roč. 1865, č. 7 (2017), s. 768-775 ISSN 1570-9639 R&D Projects: GA ČR(CZ) GA16-20229S; GA MŠk(CZ) LO1509 Institutional support: RVO:61388971 Keywords : Mass spectrometry imaging * De novo sequencing * Siderophores Subject RIV: EE - Microbiology, Virology OBOR OECD: Microbiology Impact factor: 2.773, year: 2016

  11. A Pivotal Study of Optoacoustic Imaging to Diagnose Benign and Malignant Breast Masses: A New Evaluation Tool for Radiologists.

    Science.gov (United States)

    Neuschler, Erin I; Butler, Reni; Young, Catherine A; Barke, Lora D; Bertrand, Margaret L; Böhm-Vélez, Marcela; Destounis, Stamatia; Donlan, Pamela; Grobmyer, Stephen R; Katzen, Janine; Kist, Kenneth A; Lavin, Philip T; Makariou, Erini V; Parris, Tchaiko M; Schilling, Kathy J; Tucker, F Lee; Dogan, Basak E

    2018-05-01

    Purpose To compare the diagnostic utility of an investigational optoacoustic imaging device that fuses laser optical imaging (OA) with grayscale ultrasonography (US) to grayscale US alone in differentiating benign and malignant breast masses. Materials and Methods This prospective, 16-site study of 2105 women (study period: 12/21/2012 to 9/9/2015) compared Breast Imaging Reporting and Data System (BI-RADS) categories assigned by seven blinded independent readers to benign and malignant breast masses using OA/US versus US alone. BI-RADS 3, 4, or 5 masses assessed at diagnostic US with biopsy-proven histologic findings and BI-RADS 3 masses stable at 12 months were eligible. Independent readers reviewed US images obtained with the OA/US device, assigned a probability of malignancy (POM) and BI-RADS category, and locked results. The same independent readers then reviewed OA/US images, scored OA features, and assigned OA/US POM and a BI-RADS category. Specificity and sensitivity were calculated for US and OA/US. Benign and malignant mass upgrade and downgrade rates, positive and negative predictive values, and positive and negative likelihood ratios were compared. Results Of 2105 consented subjects with 2191 masses, 100 subjects (103 masses) were analyzed separately as a training population and excluded. An additional 202 subjects (210 masses) were excluded due to technical failures or incomplete imaging, 72 subjects (78 masses) due to protocol deviations, and 41 subjects (43 masses) due to high-risk histologic results. Of 1690 subjects with 1757 masses (1079 [61.4%] benign and 678 [38.6%] malignant masses), OA/US downgraded 40.8% (3078/7535) of benign mass reads, with a specificity of 43.0% (3242/7538, 99% confidence interval [CI]: 40.4%, 45.7%) for OA/US versus 28.1% (2120/7543, 99% CI: 25.8%, 30.5%) for the internal US of the OA/US device. OA/US exceeded US in specificity by 14.9% (P < .0001; 99% CI: 12.9, 16.9%). Sensitivity for biopsied malignant masses was 96

  12. OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    de Raad, Markus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); de Rond, Tristan [Univ. of California, Berkeley, CA (United States); Rübel, Oliver [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Keasling, Jay D. [Univ. of California, Berkeley, CA (United States); Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Technical Univ. of Denmark, Lyngby (Denmark); Northen, Trent R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Bowen, Benjamin P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States)

    2017-05-03

    Mass spectrometry imaging (MSI) has primarily been applied in localizing biomolecules within biological matrices. Although well-suited, the application of MSI for comparing thousands of spatially defined spotted samples has been limited. One reason for this is a lack of suitable and accessible data processing tools for the analysis of large arrayed MSI sample sets. In this paper, the OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http://openmsi.nersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was evaluated by analyzing an MSI data set of a high-throughput glycoside hydrolase activity screen comprising 384 samples arrayed onto a NIMS surface at a 450 μm spacing, decreasing analysis time >100-fold while maintaining robust spot-finding. The utility of OMAAT was demonstrated for screening metabolic activities of different sized soil particles, including hydrolysis of sugars, revealing a pattern of size dependent activities. Finally, these results introduce OMAAT as an effective toolkit for analyzing spatially defined samples in MSI. OMAAT runs on all major operating systems, and the source code can be obtained from the following GitHub repository: https://github.com/biorack/omaat.

  13. MALDI Mass Spectrometry Imaging for Evaluation of Therapeutics in Colorectal Tumor Organoids

    Science.gov (United States)

    Liu, Xin; Flinders, Colin; Mumenthaler, Shannon M.; Hummon, Amanda B.

    2018-03-01

    Patient-derived colorectal tumor organoids (CTOs) closely recapitulate the complex morphological, phenotypic, and genetic features observed in in vivo tumors. Therefore, evaluation of drug distribution and metabolism in this model system can provide valuable information to predict the clinical outcome of a therapeutic response in individual patients. In this report, we applied matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) to examine the spatial distribution of the drug irinotecan and its metabolites in CTOs from two patients. Irinotecan is a prodrug and is often prescribed as part of therapeutic regimes for patients with advanced colorectal cancer. Irinotecan shows a time-dependent and concentration-dependent permeability and metabolism in the CTOs. More interestingly, the active metabolite SN-38 does not co-localize well with the parent drug irinotecan and the inactive metabolite SN-38G. The phenotypic effect of irinotecan metabolism was also confirmed by a viability study showing significantly reduced proliferation in the drug treated CTOs. MALDI-MSI can be used to investigate various pharmaceutical compounds in CTOs derived from different patients. By analyzing multiple CTOs from a patient, this method could be used to predict patient-specific drug responses and help to improve personalized dosing regimens. [Figure not available: see fulltext.

  14. Imaging of benign and malignant soft tissue masses of the foot

    International Nuclear Information System (INIS)

    Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus; Rechl, Hans

    2003-01-01

    The foot is a relatively uncommon site of neoplastic and non-neoplastic soft tissue tumors. Although it contains a relatively small amount of somatic soft tissue elements, the foot is considerably rich in tendons, fasciae, retinaculae, and synovium. Corresponding to this distribution of soft tissue elements, some soft tissue lesions, such as giant cell tumor of tendon sheath, fibromatosis, and synovial sarcoma, are commonly seen in this location. Vascular tumors represent common soft tissue masses of the foot as well. Magnetic resonance imaging is the modality of choice in the assessment of soft tissue tumors. The presence of a suspected lesion can be confirmed and tumor margins can be defined accurately. In general, MRI does not provide histologic specificity, but considering some MR features may often help in correctly distinguishing benign from malignant lesions. In addition, characteristic features of the most common benign tumors (i.e., fibromatosis, cavernous hemangioma) and reactive processes of the foot (ganglion cyst, Morton's neuroma) often suggest a specific diagnosis. (orig.)

  15. High Spatial Resolution Imaging Mass Spectrometry of Human Optic Nerve Lipids and Proteins

    Science.gov (United States)

    Anderson, David M. G.; Spraggins, Jeffrey M.; Rose, Kristie L.; Schey, Kevin L.

    2015-06-01

    The human optic nerve carries signals from the retina to the visual cortex of the brain. Each optic nerve is comprised of approximately one million nerve fibers that are organized into bundles of 800-1200 fibers surrounded by connective tissue and supportive glial cells. Damage to the optic nerve contributes to a number of blinding diseases including: glaucoma, neuromyelitis optica, optic neuritis, and neurofibromatosis; however, the molecular mechanisms of optic nerve damage and death are incompletely understood. Herein we present high spatial resolution MALDI imaging mass spectrometry (IMS) analysis of lipids and proteins to define the molecular anatomy of the human optic nerve. The localization of a number of lipids was observed in discrete anatomical regions corresponding to myelinated and unmyelinated nerve regions as well as to supporting connective tissue, glial cells, and blood vessels. A protein fragment from vimentin, a known intermediate filament marker for astrocytes, was observed surrounding nerved fiber bundles in the lamina cribrosa region. S100B was also found in supporting glial cell regions in the prelaminar region, and the hemoglobin alpha subunit was observed in blood vessel areas. The molecular anatomy of the optic nerve defined by MALDI IMS provides a firm foundation to study biochemical changes in blinding human diseases.

  16. Spatial organization of lipids in the human retina and optic nerve by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Zemski Berry, Karin A; Gordon, William C; Murphy, Robert C; Bazan, Nicolas G

    2014-03-01

    MALDI imaging mass spectrometry (IMS) was used to characterize lipid species within sections of human eyes. Common phospholipids that are abundant in most tissues were not highly localized and observed throughout the accessory tissue, optic nerve, and retina. Triacylglycerols were highly localized in accessory tissue, whereas sulfatide and plasmalogen glycerophosphoethanolamine (PE) lipids with a monounsaturated fatty acid were found enriched in the optic nerve. Additionally, several lipids were associated solely with the inner retina, photoreceptors, or retinal pigment epithelium (RPE); a plasmalogen PE lipid containing DHA (22:6), PE(P-18:0/22:6), was present exclusively in the inner retina, and DHA-containing glycerophosphatidylcholine (PC) and PE lipids were found solely in photoreceptors. PC lipids containing very long chain (VLC)-PUFAs were detected in photoreceptors despite their low abundance in the retina. Ceramide lipids and the bis-retinoid, N-retinylidene-N-retinylethanolamine, was tentatively identified and found only in the RPE. This MALDI IMS study readily revealed the location of many lipids that have been associated with degenerative retinal diseases. Complex lipid localization within retinal tissue provides a global view of lipid organization and initial evidence for specific functions in localized regions, offering opportunities to assess their significance in retinal diseases, such as macular degeneration, where lipids have been implicated in the disease process.

  17. Metabolic Profiling Directly from the Petri Dish Using Nanospray Desorption Electrospray Ionization Imaging Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Watrous, Jeramie D.; Roach, Patrick J.; Heath, Brandi S.; Alexandrov, Theodore; Laskin, Julia; Dorrestein, Pieter C.

    2013-11-05

    Understanding molecular interaction pathways in complex biological systems constitutes a treasure trove of knowledge that might facilitate the specific, chemical manipulation of the countless microbiological systems that occur throughout our world. However, there is a lack of methodologies that allow the direct investigation of chemical gradients and interactions in living biological systems, in real time. Here, we report the use of nanospray desorption electrospray ionization (nanoDESI) imaging mass spectrometry for in vivo metabolic profiling of living bacterial colonies directly from the Petri dish with absolutely no sample preparation needed. Using this technique, we investigated single colonies of Shewanella oneidensis MR-1, Bacillus subtilis 3610, and Streptomyces coelicolor A3(2) as well as a mixed biofilm of S. oneidensis MR-1 and B. subtilis 3610. Data from B. subtilis 3610 and S. coelicolor A3(2) provided a means of validation for the method while data from S. oneidensis MR-1 and the mixed biofilm showed a wide range of compounds that this bacterium uses for the dissimilatory reduction of extracellular metal oxides, including riboflavin, iron-bound heme and heme biosynthetic intermediates, and the siderophore putrebactin.

  18. Mass spectrometry imaging: Towards mapping the elemental and molecular composition of the rhizosphere

    Energy Technology Data Exchange (ETDEWEB)

    Veličković, Dušan; Anderton, Christopher R.

    2017-06-01

    This short review will discuss and provide perspective into the utilization of mass spectrometry imaging (MSI) in studying the rhizosphere. It also serves to compliment the multi-omic focused review by White et al. in this journal issue, as MSI is capable of elucidating chemical distributions within samples of interest in an in situ fashions, and thus can provide spatial context to MS omics data in complementary experimental endeavors. The majority of reported MSI-based studies of plant-microbe interactions have focused on the phyllosphere and ‘associated rhizosphere’ (e.g., material that is not removed during harvesting), as sample preparation for these in situ analyses tends to be a limiting factor. These studies have provided valuable insight into the spatial arrangement of proteins, peptides, lipids, and other metabolites within these systems. We intend for this short review to be a primer about the history of MSI and its role in plant-microbe analysis. Along the way we reference many comprehensive reviews for the interested reader. Lastly, we offer a perspective on the future of MSI and its use in understanding the molecular transformations beyond what we coined as the ‘associated rhizosphere’ to the rest of rhizosphere zone and into the bulk soil.

  19. Automated MALDI Matrix Coating System for Multiple Tissue Samples for Imaging Mass Spectrometry

    Science.gov (United States)

    Mounfield, William P.; Garrett, Timothy J.

    2012-03-01

    Uniform matrix deposition on tissue samples for matrix-assisted laser desorption/ionization (MALDI) is key for reproducible analyte ion signals. Current methods often result in nonhomogenous matrix deposition, and take time and effort to produce acceptable ion signals. Here we describe a fully-automated method for matrix deposition using an enclosed spray chamber and spray nozzle for matrix solution delivery. A commercial air-atomizing spray nozzle was modified and combined with solenoid controlled valves and a Programmable Logic Controller (PLC) to control and deliver the matrix solution. A spray chamber was employed to contain the nozzle, sample, and atomized matrix solution stream, and to prevent any interference from outside conditions as well as allow complete control of the sample environment. A gravity cup was filled with MALDI matrix solutions, including DHB in chloroform/methanol (50:50) at concentrations up to 60 mg/mL. Various samples (including rat brain tissue sections) were prepared using two deposition methods (spray chamber, inkjet). A linear ion trap equipped with an intermediate-pressure MALDI source was used for analyses. Optical microscopic examination showed a uniform coating of matrix crystals across the sample. Overall, the mass spectral images gathered from tissues coated using the spray chamber system were of better quality and more reproducible than from tissue specimens prepared by the inkjet deposition method.

  20. Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Bhandari, Deepak [ORNL; Lorenz, Matthias [ORNL; Van Berkel, Gary J [ORNL

    2014-01-01

    RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. Methods: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) setup to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. Results: The estimated capture efficiency of laser ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~ 2.8 mm2) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution of not only particulates, but also gaseous products of the laser ablation. The use of DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR slides based on the ability to distinguish features present both in the optical and in the

  1. Characterization of a novel miniaturized burst-mode infrared laser system for IR-MALDESI mass spectrometry imaging.

    Science.gov (United States)

    Ekelöf, Måns; Manni, Jeffrey; Nazari, Milad; Bokhart, Mark; Muddiman, David C

    2018-03-01

    Laser systems are widely used in mass spectrometry as sample probes and ionization sources. Mid-infrared lasers are particularly suitable for analysis of high water content samples such as animal and plant tissues, using water as a resonantly excited sacrificial matrix. Commercially available mid-IR lasers have historically been bulky and expensive due to cooling requirements. This work presents a novel air-cooled miniature mid-IR laser with adjustable burst-mode output and details an evaluation of its performance for mass spectrometry imaging. The miniature laser was found capable of generating sufficient energy for complete ablation of animal tissue in the context of an IR-MALDESI experiment with exogenously added ice matrix, yielding several hundred confident metabolite identifications. Graphical abstract The use of a novel miniature 2.94 μm burst-mode laser in IR-MALDESI allows for rapid and sensitive mass spectrometry imaging of a whole mouse.

  2. The Demographics and Properties of Wide-Orbit, Planetary-Mass Companions from PSF Fitting of Spitzer/IRAC Images

    Science.gov (United States)

    Martinez, Raquel; Kraus, Adam L.

    2017-06-01

    Over the past decade, a growing population of planetary-mass companions ( 100 AU) from their host stars, challenging existing models of both star and planet formation. It is unclear whether these systems represent the low-mass extreme of stellar binary formation or the high-mass and wide-orbit extreme of planet formation theories, as various proposed formation pathways inadequately explain the physical and orbital aspects of these systems. Even so, determining which scenario best reproduces the observed characteristics of the PMCs will come once a statistically robust sample of directly-imaged PMCs are found and studied.We are developing an automated pipeline to search for wide-orbit PMCs to young stars in Spitzer/IRAC images. A Markov Chain Monte Carlo (MCMC) algorithm is the backbone of our novel point spread function (PSF) subtraction routine that efficiently creates and subtracts χ2-minimizing instrumental PSFs, simultaneously measuring astrometry and infrared photometry of these systems across the four IRAC channels (3.6 μm, 4.5 μm, 5.8 μm, and 8 μm). In this work, we present the results of a Spitzer/IRAC archival imaging study of 11 young, low-mass (0.044-0.88 M⊙ K3.5-M7.5) stars known to have faint, low-mass companions in 3 nearby star-forming regions (Chameleon, Taurus, and Upper Scorpius). We characterize the systems found to have low-mass companions with non-zero [I1] - [I4] colors, potentially signifying the presence of a circum(sub?)stellar disk. Plans for future pipeline improvements and paths forward will also be discussed. Once this computational foundation is optimized, the stage is set to quickly scour the nearby star-forming regions already imaged by Spitzer, identify potential candidates for further characterization with ground- or space-based telescopes, and increase the number of widely-separated PMCs known.

  3. Cryo-sectioning of mice for whole-body imaging of drugs and metabolites with desorption electrospray ionization mass spectrometry imaging - a simplified approach

    DEFF Research Database (Denmark)

    Okutan, Seda; Hansen, Harald S; Janfelt, Christian

    2016-01-01

    A method is presented for whole-body imaging of drugs and metabolites in mice with desorption electrospray ionization mass spectrometry imaging (DESI-MSI). Unlike most previous approaches to whole-body imaging which are based on cryo-sectioning using a cryo-macrotome, the presented approach...... to simple, sensitive and highly selective whole-body imaging in drug distribution and metabolism studies....... is based on use of the cryo-microtome which is found in any histology lab. The tissue sections are collected on tape which is analyzed directly by DESI-MSI. The method is demonstrated on mice which have been dosed intraperitoneally with the antidepressive drug amitriptyline. By combining full...

  4. Associations between Chinese/Asian versus Western mass media influences and body image disturbances of young Chinese women.

    Science.gov (United States)

    Jackson, Todd; Jiang, Chengcheng; Chen, Hong

    2016-06-01

    In this study, we evaluated associations of experiences with mass media imported from Western nations such as the United States versus mass media from China and other Asian countries with eating and body image disturbances of young Chinese women. Participating women (N=456) completed self-report measures of disordered eating, specific sources of appearance dissatisfaction (fatness, facial features, stature), and Western versus Chinese/Asian mass media influences. The sample was significantly more likely to report perceived pressure from, comparisons with, and preferences for physical appearance depictions in Chinese/Asian mass media than Western media. Chinese/Asian media influences also combined for more unique variance in prediction models for all disturbances except stature concerns. While experiences with Western media were related to disturbances as well, the overall impact of Chinese/Asian media influences was more prominent. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Constant-Distance Mode Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging of Biological Samples with Complex Topography

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Son N.; Liyu, Andrey V.; Chu, Rosalie K.; Anderton, Christopher R.; Laskin, Julia

    2017-01-17

    A new approach for constant distance mode mass spectrometry imaging of biological samples using nanospray desorption electrospray ionization (nano-DESI MSI) was developed by integrating a shear-force probe with nano-DESI probe. The technical concept and basic instrumental setup as well as general operation of the system are described. Mechanical dampening of resonant oscillations due to the presence of shear forces between the probe and the sample surface enables constant-distance imaging mode via a computer controlled closed feedback loop. The capability of simultaneous chemical and topographic imaging of complex biological samples is demonstrated using living Bacillus Subtilis ATCC 49760 colonies on agar plates. The constant-distance mode nano-DESI MSI enabled imaging of many metabolites including non-ribosomal peptides (surfactin, plipastatin and iturin) and iron-bound heme on the surface of living bacterial colonies ranging in diameter from 10 mm to 13 mm with height variations of up to 0.8 mm above the agar plate. Co-registration of ion images to topographic images provided higher-contrast images. Constant-mode nano-DESI MSI is ideally suited for imaging biological samples of complex topography in their native state.

  6. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging.

    Science.gov (United States)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael; Boudiaf, Mourad; Hoeffel, Christine; Soyer, Philippe

    2015-08-01

    To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n=17; intrahepatic, n=11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800s/mm(2)). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (Philar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation coefficient=16.6%). There is a trend towards a common appearance of intrahepatic and hilar mass-forming cholangiocarcinomas on DW-MRI but variations may be observed. Familiarity with these variations may improve the diagnosis of mass-forming cholangiocarcinoma. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Localized intrahepatic bile duct dilatation without a visible mass or stone as depicted on CT images: findings of malignancy prediction

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ju Wan; Kim, Gab Chul; Jeong, Han Young; Lee, Hui Joong; Lee, Jae Hyuck; Ryeom, Hun Kyu [Kyungpook National University Hospital, Daegu (Korea, Republic of); Kim, Jong Yeol [Kumi Cha Medical Center, Collge of Medicine, Pochon CHA University, Kumi (Korea, Republic of)

    2008-09-15

    This study was preformed to evaluate factors that can predict the presence of a malignancy for localized intrahepatic bile duct dilatation without a visible mass or stone as depicted on CT images. A total of 29 patients (male: 16, female: 13) who had localized intrahepatic bile duct dilatation without a visible mass, stone or injury as depicted on CT images were included in the study. A history of extrahepatic malignancy and biliary stone disease, tumor marker levels, CT findings of the intrahepatic bile duct and associated findings were reviewed. The findings were analyzed between two groups (patients with a malignancy and patients with benign disease) on follow-up. In 29 patient, 11 patients had malignant lesions (four metastases and seven cholangiocarcinomas). The history of an extrahepatic malignancy and the shape of an intrahepatic duct obstruction or stenosis as seen on CT were significantly correlated with the results between the benign and malignant group of patients. The follow-up results of the malignant group of patients indicated that for six patients who had developed a new mass, one patient each showed aggravation of ductal dilatation and thickening of the ductal wall. When a patient with localized intrahepatic bile duct dilatation without a definite cause has a history of an extrahepatic malignancy or shows abrupt tapering or irregular narrowing on CT images, short-term follow-up should be performed. The patient should be investigated carefully for mass formation or a change of the dilated bile duct due to a possibility of malignant ductal dilatation.

  8. Detection of Metastatic Breast and Thyroid Cancer in Lymph Nodes by Desorption Electrospray Ionization Mass Spectrometry Imaging

    Science.gov (United States)

    Zhang, Jialing; Feider, Clara L.; Nagi, Chandandeep; Yu, Wendong; Carter, Stacey A.; Suliburk, James; Cao, Hop S. Tran; Eberlin, Livia S.

    2017-06-01

    Ambient ionization mass spectrometry has been widely applied to image lipids and metabolites in primary cancer tissues with the purpose of detecting and understanding metabolic changes associated with cancer development and progression. Here, we report the use of desorption electrospray ionization mass spectrometry (DESI-MS) to image metastatic breast and thyroid cancer in human lymph node tissues. Our results show clear alterations in lipid and metabolite distributions detected in the mass spectra profiles from 42 samples of metastatic thyroid tumors, metastatic breast tumors, and normal lymph node tissues. 2D DESI-MS ion images of selected molecular species allowed discrimination and visualization of specific histologic features within tissue sections, including regions of metastatic cancer, adjacent normal lymph node, and fibrosis or adipose tissues, which strongly correlated with pathologic findings. In thyroid cancer metastasis, increased relative abundances of ceramides and glycerophosphoinisitols were observed. In breast cancer metastasis, increased relative abundances of various fatty acids and specific glycerophospholipids were seen. Trends in the alterations in fatty acyl chain composition of lipid species were also observed through detailed mass spectra evaluation and chemical identification of molecular species. The results obtained demonstrate DESI-MSI as a potential clinical tool for the detection of breast and thyroid cancer metastasis in lymph nodes, although further validation is needed. [Figure not available: see fulltext.

  9. Localized intrahepatic bile duct dilatation without a visible mass or stone as depicted on CT images: findings of malignancy prediction

    International Nuclear Information System (INIS)

    Choi, Ju Wan; Kim, Gab Chul; Jeong, Han Young; Lee, Hui Joong; Lee, Jae Hyuck; Ryeom, Hun Kyu; Kim, Jong Yeol

    2008-01-01

    This study was preformed to evaluate factors that can predict the presence of a malignancy for localized intrahepatic bile duct dilatation without a visible mass or stone as depicted on CT images. A total of 29 patients (male: 16, female: 13) who had localized intrahepatic bile duct dilatation without a visible mass, stone or injury as depicted on CT images were included in the study. A history of extrahepatic malignancy and biliary stone disease, tumor marker levels, CT findings of the intrahepatic bile duct and associated findings were reviewed. The findings were analyzed between two groups (patients with a malignancy and patients with benign disease) on follow-up. In 29 patient, 11 patients had malignant lesions (four metastases and seven cholangiocarcinomas). The history of an extrahepatic malignancy and the shape of an intrahepatic duct obstruction or stenosis as seen on CT were significantly correlated with the results between the benign and malignant group of patients. The follow-up results of the malignant group of patients indicated that for six patients who had developed a new mass, one patient each showed aggravation of ductal dilatation and thickening of the ductal wall. When a patient with localized intrahepatic bile duct dilatation without a definite cause has a history of an extrahepatic malignancy or shows abrupt tapering or irregular narrowing on CT images, short-term follow-up should be performed. The patient should be investigated carefully for mass formation or a change of the dilated bile duct due to a possibility of malignant ductal dilatation

  10. Direct Visualization of Neurotransmitters in Rat Brain Slices by Desorption Electrospray Ionization Mass Spectrometry Imaging (DESI - MS)

    Science.gov (United States)

    Fernandes, Anna Maria A. P.; Vendramini, Pedro H.; Galaverna, Renan; Schwab, Nicolas V.; Alberici, Luciane C.; Augusti, Rodinei; Castilho, Roger F.; Eberlin, Marcos N.

    2016-12-01

    Mass spectrometry imaging (MSI) of neurotransmitters has so far been mainly performed by matrix-assisted laser desorption/ionization (MALDI) where derivatization reagents, deuterated matrix and/or high resolution, or tandem MS have been applied to circumvent problems with interfering ion peaks from matrix and from isobaric species. We herein describe the application of desorption electrospray ionization mass spectrometry imaging (DESI)-MSI in rat brain coronal and sagittal slices for direct spatial monitoring of neurotransmitters and choline with no need of derivatization reagents and/or deuterated materials. The amino acids γ-aminobutyric (GABA), glutamate, aspartate, serine, as well as acetylcholine, dopamine, and choline were successfully imaged using a commercial DESI source coupled to a hybrid quadrupole-Orbitrap mass spectrometer. The spatial distribution of the analyzed compounds in different brain regions was determined. We conclude that the ambient matrix-free DESI-MSI is suitable for neurotransmitter imaging and could be applied in studies that involve evaluation of imbalances in neurotransmitters levels.

  11. THE LEECH EXOPLANET IMAGING SURVEY: ORBIT AND COMPONENT MASSES OF THE INTERMEDIATE-AGE, LATE-TYPE BINARY NO UMa

    Energy Technology Data Exchange (ETDEWEB)

    Schlieder, Joshua E. [NASA Ames Research Center, Space Science and Astrobiology Division, MS 245-6, Moffett Field, CA 94035 (United States); Skemer, Andrew J.; Hinz, Philip; Leisenring, Jarron; Defrère, Denis; Close, Laird M.; Eisner, Josh A. [Steward Observatory, Department of Astronomy, University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Maire, Anne-Lise; Desidera, Silvano [INAF—Osservatorio Astronomico di Padova, Vicolo dell’Osservatorio 5, I-35122, Padova (Italy); Skrutskie, Michael F. [Department of Astronomy, University of Virginia, Charlottesville, VA, 22904 (United States); Bailey, Vanessa [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, Stanford, CA 94305 (United States); Esposito, Simone [INAF—Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125, Firenze (Italy); Strassmeier, Klaus G.; Weber, Michael [Leibniz-Institut für Astrophysik Potsdam (AIP), An der Sternwarte 16, D-14482, Potsdam (Germany); Biller, Beth A.; Bonnefoy, Mickaël; Buenzli, Esther; Henning, Thomas [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117, Heidelberg (Germany); Crepp, Justin R. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN, 46556 (United States); Hofmann, Karl-Heinz, E-mail: joshua.e.schlieder@nasa.gov [Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, D-53121, Bonn (Germany); and others

    2016-02-10

    We present high-resolution Large Binocular Telescope LBTI/LMIRcam images of the spectroscopic and astrometric binary NO UMa obtained as part of the LBT Interferometer Exozodi Exoplanet Common Hunt exoplanet imaging survey. Our H-, K{sub s}-, and L′-band observations resolve the system at angular separations <0.″09. The components exhibit significant orbital motion over a span of ∼7 months. We combine our imaging data with archival images, published speckle interferometry measurements, and existing spectroscopic velocity data to solve the full orbital solution and estimate component masses. The masses of the K2.0 ± 0.5 primary and K6.5 ± 0.5 secondary are 0.83 ± 0.02 M{sub ⊙} and 0.64 ± 0.02 M{sub ⊙}, respectively. We also derive a system distance of d = 25.87 ± 0.02 pc and revise the Galactic kinematics of NO UMa. Our revised Galactic kinematics confirm NO UMa as a nuclear member of the ∼500 Myr old Ursa Major moving group, and it is thus a mass and age benchmark. We compare the masses of the NO UMa binary components to those predicted by five sets of stellar evolution models at the age of the Ursa Major group. We find excellent agreement between our measured masses and model predictions with little systematic scatter between the models. NO UMa joins the short list of nearby, bright, late-type binaries having known ages and fully characterized orbits.

  12. Air trapping on computed tomography images of healthy individuals: effects of respiration and body mass index

    International Nuclear Information System (INIS)

    Hashimoto, M.; Tate, E.; Watarai, J.; Sasaki, M.

    2006-01-01

    Aim: To evaluate the relationships of changes in the lung area during respiration and of individual body mass index (BMI) to air trapping on expiratory computed tomography (CT) in young non-smoking adults of either gender. Methods: The volunteers were 10 women and 10 men (mean age 25.7 years) who were healthy lifelong non-smokers. We obtained both end-inspiratory and end-expiratory CT images at three levels: the upper, middle and lower lung. The ratio of cross-sectional lung area upon expiration to cross-sectional lung area upon inspiration (lung area ratio) was determined for each lung at each of the three levels. In cases showing air trapping, we calculated the percentage of area of air in relation to the total lung area in each section. BMI was calculated for each participant. Results: Air trapping was present in dependent areas of the lungs of 6 women and 5 men. The mean percentage of area of air trapped was statistically greater for men (9.8 ± 9.2%) than for women (4.9 ± 5.2%). The mean lung area ratio was 0.52 ± 0 14 among volunteers with air trapping (66 sections) and 0.69 ± 0.12 among those without air trapping (54 sections) (p < 0.001). At each lung level, the mean lung area ratio was greater in individuals with air trapping than in those without. Mean BMI was also greater in these people (p = 0.009). Conclusion: Change in the respiratory lung area and BMI contribute to development of air trapping

  13. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  14. The diverse pathology and kinetics of mass, nonmass and focus enhancement on MR imaging of the breast

    Science.gov (United States)

    Jansen, Sanaz A.; Shimauchi, Akiko; Zak, Lindsay; Fan, Xiaobing; Karczmar, Gregory S.; Newstead, Gillian M.

    2011-01-01

    Purpose To compare the pathology and kinetic characteristics of breast lesions with focus, mass and nonmass-like enhancement. Materials and Methods 852 MRI detected breast lesions in 697 patients were selected for an IRB approved review. Patients underwent dynamic contrast enhanced MRI using one pre and three to six post-contrast T1 weighted images. The ‘type’ of enhancement was classified as mass, non-mass or focus, and kinetic curves quantified by the initial enhancement percentage (E1), time to peak enhancement (Tpeak) and signal enhancement ratio (SER). These kinetic parameters were compared between malignant and benign lesions within each morphologic type. Results 552 lesions were classified as mass (396 malignant, 156 benign), 261 as nonmass (212 malignant,49 benign) and 39 as focus (9 malignant,30 benign). The most common pathology of malignant/benign lesions by morphology: for mass, invasive ductal carcinoma/fibroadenoma; for nonmass, ductal carcinoma in situ (DCIS)/fibrocystic change(FCC); for focus, DCIS/FCC. Benign mass lesions exhibited significantly lower E1, longer Tpeak and lower SER compared with malignant mass lesions (p < 0.0001). Benign nonmass lesions exhibited only a lower SER compared to malignant nonmass lesions (p<0.01). Conclusions By considering the diverse pathology and kinetic characteristics of different lesion morphologies, diagnostic accuracy may be improved. PMID:21591007

  15. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fattach, Hassan El, E-mail: hassangreenmed@gmail.com [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); UMR INSERM 965-Paris 7 “Angiogenèse et recherche translationnelle”, 2 rue Amboise Paré, 75010 Paris (France); Guerrache, Youcef, E-mail: docyoucef05@yahoo.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dautry, Raphael, E-mail: raphael.dautry@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); and others

    2015-08-15

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm{sup 2}). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10{sup −3} mm{sup 2}/s ± 0.221 × 10{sup −3} mm{sup 2}/s; range: 0.616 × 10{sup −3} mm{sup 2}/s to 2.050 × 10{sup −3} mm{sup 2}/s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10{sup −3} mm{sup 2}/s ± 0.187 × 10{sup −3} mm{sup 2}/s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted

  16. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael

    2015-01-01

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm 2 ). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10 −3 mm 2 /s ± 0.221 × 10 −3 mm 2 /s; range: 0.616 × 10 −3 mm 2 /s to 2.050 × 10 −3 mm 2 /s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10 −3 mm 2 /s ± 0.187 × 10 −3 mm 2 /s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation

  17. Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study

    International Nuclear Information System (INIS)

    Timberg, P.; Baath, M.; Andersson, I.; Mattsson, S.; Tingberg, A.; Ruschin, M.

    2012-01-01

    Purpose: To investigate the visibility of simulated lesions in digital breast tomosynthesis (BT) image volumes compared with 2D digital mammography (DM). Methods: Simulated lesions (masses and microcalcifications) were added to images of the same women acquired on a DM system (Mammomat Novation, Siemens) and a BT prototype. The same beam quality was used for the DM and BT acquisitions. The total absorbed dose resulting from a 25-projection BT acquisition and reconstruction (BT 25 ) was approximately twice that of a single DM view. By excluding every other projection image from the reconstruction (BT 13 ), approximately the same dose as in DM was effected. Simulated microcalcifications were digitally added with varying contrast to the DM and BT images. Simulated masses with 8 mm diameter were also added to BT images. A series of 4-alternative forced choice (4AFC) human observer experiments were conducted. Four medical physicists participated in all experiments, each consisting of 60 trials per experimental condition. The observers interpreted the BT image volumes in cine-mode at a fixed image sequence speed. The required threshold contrast (S t ) to achieve a detectability index (d') of 2.5 (i.e., 92.5% correct decisions) was determined. Results: The S t for mass detection in DM was approximately a factor of 2 higher than required in BT indicating that the detection of masses was improved under BT conditions compared to DM. S t for microcalcification detection was higher for BT than for DM at both BT dose levels (BT 25 and BT 13 ), with a statistically significant difference in S t between DM and BT 13 . These results indicate a dose-dependent decrease in detection performance in BT for detection of microcalcifications. Conclusions: In agreement with previous investigations, masses of size 8 mm can be detected with less contrast in BT than in DM indicating improved detection performance for BT. However, for the investigated microcalcifications, the results of this

  18. Position sensitive detection coupled to high-resolution time-of-flight mass spectrometry: Imaging for molecular beam deflection experiments

    International Nuclear Information System (INIS)

    Abd El Rahim, M.; Antoine, R.; Arnaud, L.; Barbaire, M.; Broyer, M.; Clavier, Ch.; Compagnon, I.; Dugourd, Ph.; Maurelli, J.; Rayane, D.

    2004-01-01

    We have developed and tested a high-resolution time-of-flight mass spectrometer coupled to a position sensitive detector for molecular beam deflection experiments. The major achievement of this new spectrometer is to provide a three-dimensional imaging (X and Y positions and time-of-flight) of the ion packet on the detector, with a high acquisition rate and a high resolution on both the mass and the position. The calibration of the experimental setup and its application to molecular beam deflection experiments are discussed

  19. Focal Pancreatitis Mimicking Pancreatic Mass: Magnetic Resonance Imaging (MRI)/Magnetic Resonance Cholangiopancreatography (MRCP) Findings Including Diffusion-Weighted MRI

    International Nuclear Information System (INIS)

    Momtahen, A.J.; Balci, N.C.; Alkaade, S.; Akduman, E.I.; Burton, F.R.

    2008-01-01

    Background: Focal pancreatitis (FP) is a confined inflammation that mimics a pancreatic mass. Its imaging diagnosis is important to avoid unnecessary procedures. Purpose: To describe the spectrum of magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted MRI (DWI) findings of focal pancreatitis mimicking pancreatic masses. Material and Methods: Findings of MRI/MRCP including DWI with a b value of 0 and 600 s/mm2 in 14 patients with pancreatic masses on MRI were retrospectively reviewed and compared to normal pancreas in 14 patients as a control group. Results: FP revealed hypointense signal intensity (SI) (3/14), hypo- to isointense SI (7/14), or isointense SI (4/14) on T1-weighted images, and hypointense SI (1/14), isointense SI (5/14), iso- to hyperintense SI (7/14), or hyperintense SI (1/14) on T2-weighted images compared to remaining pancreas (RP). MRCP images revealed dilatation of the common bile duct (CBD) and main pancreatic duct (MPD) (5/14), dilatation of the MPD only (3/14), dilatation of the CBD only (3/14), and normal MPD and CBD (3/14). Both FP and RP revealed three types of time-signal intensity curves: 1) rapid rise to a peak, with a rapid decline (FP=2, RP=4), 2) slow rise to a peak, followed by a slow decline (FP=5, RP=4), and 3) slower rise to a peak, with a slow decline or plateau (FP=7, RP=6). Mean apparent diffusion coefficient (ADC) values for FP and RP were 2.09±0.18 and 2.03±0.2x10 -3 mm 2 /s, respectively. ADC values of FP and RP revealed no significant difference. Conclusion: The spectrum of imaging findings of focal pancreatitis on MRI/MRCP including DWI was described. Findings of FP were not distinctive as compared to the remaining pancreas

  20. Analysis of the image of pion-emitting sources in the source center-of-mass frame

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Yanyu; Feng, Qichun; Huo, Lei; Zhang, Jingbo; Liu, Jianli; Tang, Guixin [Harbin Institute of Technology, Department of Physics, Harbin, Heilongjiang (China); Zhang, Weining [Harbin Institute of Technology, Department of Physics, Harbin, Heilongjiang (China); Dalian University of Technology, School of Physics and Optoelectronic Technology, Dalian, Liaoning (China)

    2017-08-15

    In this paper, we try a method to extract the image of pion-emitting source function in the center-of-mass frame of the source (CMFS). We choose identical pion pairs according to the difference of their energy and use these pion pairs to build the correlation function. The purpose is to reduce the effect of ΔEΔt, thus the corresponding imaging result can tend to the real source function. We examine the effect of this method by comparing its results with real source functions extracted from models directly. (orig.)

  1. Masses of the Planetary Nebula Central Stars in the Galactic Globular Cluster System from HST Imaging and Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacoby, George H. [Lowell Observatory, Flagstaff, AZ 86001 (United States); Marco, Orsola De [Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109 (Australia); Davies, James [Space Telescope Science Institute, Baltimore MD 21218 (United States); Lotarevich, I. [American Museum of Natural History, New York, NY (United States); Bond, Howard E. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Harrington, J. Patrick [University of Maryland, College Park, MD (United States); Lanz, Thierry, E-mail: gjacoby@lowell.edu, E-mail: orsola.demarco@mq.edu.au, E-mail: jdavies@stsci.edu, E-mail: heb11@psu.edu, E-mail: jph@astro.umd.edu, E-mail: thierry.lanz@oca.eu [Laboratoire Lagrange, Université Côte d’Azur, Observatoire de la Côte d’Azur, CNRS, F-06304 Nice (France)

    2017-02-10

    The globular cluster (GC) system of our Galaxy contains four planetary nebulae (PNe): K 648 (or Ps 1) in M15, IRAS 18333-2357 in M22, JaFu 1 in Pal 6, and JaFu 2 in NGC 6441. Because single-star evolution at the low stellar mass of present-epoch GCs was considered incapable of producing visible PNe, their origin presented a puzzle. We imaged the PN JaFu 1 with the Hubble Space Telescope (HST) to obtain photometry of its central star (CS) and high-resolution morphological information. We imaged IRAS 18333-2357 with better depth and resolution, and we analyzed its archival HST spectra to constrain its CS temperature and luminosity. All PNe in Galactic GCs now have quality HST data, allowing us to improve CS mass estimates. We find reasonably consistent masses between 0.53 and 0.58 M {sub ⊙} for all four objects, though estimates vary when adopting different stellar evolutionary calculations. The CS mass of IRAS 18333-2357, though, depends strongly on its temperature, which remains elusive due to reddening uncertainties. For all four objects, we consider their CS and nebula masses, their morphologies, and other incongruities to assess the likelihood that these objects formed from binary stars. Although generally limited by uncertainties (∼0.02 M {sub ⊙}) in post-AGB tracks and core mass versus luminosity relations, the high-mass CS in K 648 indicates a binary origin. The CS of JaFu 1 exhibits compact, bright [O iii] and H α emission, like EGB 6, suggesting a binary companion or disk. Evidence is weaker for a binary origin of JaFu 2.

  2. Differentiation of intrahepatic mass-forming cholangiocarcinoma from hepatocellular carcinoma on gadoxetic acid-enhanced liver MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Rihyeon; Shin, Cheong-Il; Yoon, Jeong Hee; Joo, Ijin; Kim, Seong Ho; Hwang, Inpyeong [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jeong Min; Han, Joon Koo [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Institute of Radiation Medicine, Seoul (Korea, Republic of); Lee, Eun Sun; Choi, Byung Ihn [Chung-Ang University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2016-06-15

    To determine the different imaging features of intrahepatic mass-forming cholangiocarcinoma (IMCC) from hepatocellular carcinoma (HCC) on gadoxetic acid-enhanced magnetic resonance imaging (MRI). This retrospective study was institutional review board approved and the requirement for informed consent was waived. Patients who underwent gadoxetic acid-enhanced MRI with histologically confirmed IMCCs (n = 46) or HCCs (n = 58) were included. Imaging features of IMCCs and HCCs on gadoxetic acid-enhanced MRI including T2- and T1-weighted, diffusion weighted images, dynamic study and hepatobiliary phase (HBP) images were analyzed. Univariate and multivariate logistic regression analyses were performed to identify relevant differentiating features between IMCCs and HCCs. Multivariate analysis revealed heterogeneous T2 signal intensity and a hypointense rim on the HBP as suggestive findings of IMCCs and the wash-in and ''portal wash-out'' enhancement pattern as well as focal T1 high signal intensity foci as indicative of HCCs (all, p < 0.05). When we combined any three of the above four imaging features, we were able to diagnose IMCCs with 94 % (43/46) sensitivity and 86 % (50/58) specificity. Combined interpretation of enhancement characteristics including HBP images, morphologic features, and strict application of the ''portal wash-out'' pattern helped more accurate discrimination of IMCCs from HCCs. (orig.)

  3. Affinity imaging mass spectrometry (AIMS): high-throughput screening for specific small molecule interactions with frozen tissue sections.

    Science.gov (United States)

    Yoshimi, T; Kawabata, S; Taira, S; Okuno, A; Mikawa, R; Murayama, S; Tanaka, K; Takikawa, O

    2015-11-07

    A novel screening system, using affinity imaging mass spectrometry (AIMS), has been developed to identify protein aggregates or organ structures in unfixed human tissue. Frozen tissue sections are positioned on small (millimetre-scale) stainless steel chips and incubated with an extensive library of small molecules. Candidate molecules showing specific affinity for the tissue section are identified by imaging mass spectrometry (IMS). As an example application, we screened over a thousand compounds against Alzheimer's disease (AD) brain tissue and identified several compounds with high affinity for AD brain sections containing tau deposits compared to age-matched controls. It should also be possible to use AIMS to isolate chemical compounds with affinity for tissue structures or components that have been extensively modified by events such as oxidation, phosphorylation, acetylation, aggregation, racemization or truncation, for example, due to aging. It may also be applicable to biomarker screening programs.

  4. Mass Spectrometry Imaging Can Distinguish on a Proteomic Level Between Proliferative Nodules Within a Benign Congenital Nevus and Malignant Melanoma.

    Science.gov (United States)

    Lazova, Rossitza; Yang, Zhe; El Habr, Constantin; Lim, Young; Choate, Keith Adam; Seeley, Erin H; Caprioli, Richard M; Yangqun, Li

    2017-09-01

    Histopathological interpretation of proliferative nodules occurring in association with congenital melanocytic nevi can be very challenging due to their similarities with congenital malignant melanoma and malignant melanoma arising in association with congenital nevi. We hereby report a diagnostically challenging case of congenital melanocytic nevus with proliferative nodules and ulcerations, which was originally misdiagnosed as congenital malignant melanoma. Subsequent histopathological examination in consultation by one of the authors (R.L.) and mass spectrometry imaging analysis rendered a diagnosis of congenital melanocytic nevus with proliferative nodules. In this case, mass spectrometry imaging, a novel method capable of distinguishing benign from malignant melanocytic lesions on a proteomic level, was instrumental in making the diagnosis of a benign nevus. We emphasize the importance of this method as an ancillary tool in the diagnosis of difficult melanocytic lesions.

  5. Nanoparticle-assisted laser desorption/ionization mass spectrometry: Novel sample preparation methods and nanoparticle screening for plant metabolite imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagnik, Gargey B. [Iowa State Univ., Ames, IA (United States)

    2016-02-19

    The main goal of the presented research is development of nanoparticle based matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS). This dissertation includes the application of previously developed data acquisition methods, development of novel sample preparation methods, application and comparison of novel nanoparticle matrices, and comparison of two nanoparticle matrix application methods for MALDI-MS and MALDI-MS imaging.

  6. Classification of mass and normal breast tissue: A convolution neural network classifier with spatial domain and texture images

    International Nuclear Information System (INIS)

    Sahiner, B.; Chan, H.P.; Petrick, N.; Helvie, M.A.; Adler, D.D.; Goodsitt, M.M.; Wei, D.

    1996-01-01

    The authors investigated the classification of regions of interest (ROI's) on mammograms as either mass or normal tissue using a convolution neural network (CNN). A CNN is a back-propagation neural network with two-dimensional (2-D) weight kernels that operate on images. A generalized, fast and stable implementation of the CNN was developed. The input images to the CNN were obtained form the ROI's using two techniques. The first technique employed averaging and subsampling. The second technique employed texture feature extraction methods applied to small subregions inside the ROI. Features computed over different subregions were arranged as texture images, which were subsequently used as CNN inputs. The effects of CNN architecture and texture feature parameters on classification accuracy were studied. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. A data set consisting of 168 ROI's containing biopsy-proven masses and 504 ROI's containing normal breast tissue was extracted from 168 mammograms by radiologists experienced in mammography. This data set was used for training and testing the CNN. With the best combination of CNN architecture and texture feature parameters, the area under the test ROC curve reached 0.87, which corresponded to a true-positive fraction of 90% at a false positive fraction of 31%. The results demonstrate the feasibility of using a CNN for classification of masses and normal tissue on mammograms

  7. Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

    Energy Technology Data Exchange (ETDEWEB)

    Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.; Wiese-Smith, Deneille

    2007-12-01

    The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

  8. HIghMass-high H I mass, H I-rich galaxies at z ∼ 0 sample definition, optical and Hα imaging, and star formation properties

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Shan; Matsushita, Satoki [Institute of Astronomy and Astrophysics, Academia Sinica, 11F of Astronomy-Mathematics Building, National Taiwan University, Taipei 10617, Taiwan (China); Haynes, Martha P.; Giovanelli, Riccardo; Hallenbeck, Gregory; Jones, Michael G.; Adams, Elizabeth A. K. [Center for Radiophysics and Space Research, Space Sciences Building, Cornell University, Ithaca, NY 14853 (United States); Brinchmann, Jarle [Sterrewacht Leiden, Leiden University, NL-2300 RA Leiden (Netherlands); Chengalur, Jayaram N. [National Centre for Radio Astrophysics, Tata Institute for Fundamental Research, Pune 411007 (India); Hunt, Leslie K. [INAF-Osservatorio Astrofisico di Arcetri, Largo East Fermi 5, I-50125, Firenze (Italy); Masters, Karen L. [Institute of Cosmology and Gravitation, Dennis Sciama Building, Burnaby Road, Portsmouth POI 3FX (United Kingdom); Saintonge, Amelie [Department of Physics and Astronomy, University College London, Gower Place, London WC1E 6BT (United Kingdom); Spekkens, Kristine, E-mail: shan@asiaa.sinica.edu.tw [Royal Military College of Canada, Department of Physics, P.O. Box 17000, Station Forces, Kingston, ON K7K 7B4 (Canada)

    2014-09-20

    We present first results of the study of a set of exceptional H I sources identified in the 40% ALFALFA extragalactic H I survey catalog α.40 as both being H I massive (M{sub HI}>10{sup 10} M{sub ⊙}) and having high gas fractions for their stellar masses: the HIghMass galaxy sample. We analyze UV- and optical-broadband and Hα images to understand the nature of their relatively underluminous disks in optical and to test whether their high gas fractions can be tracked to higher dark matter halo spin parameters or late gas accretion. Estimates of their star formation rates (SFRs) based on spectral energy distribution fitting agree within uncertainties with the Hα luminosity inferred current massive SFRs. The H II region luminosity functions, parameterized as dN/dlog L∝L {sup α}, have standard slopes at the luminous end (α ∼ –1). The global SFRs demonstrate that the HIghMass galaxies exhibit active ongoing star formation (SF) with moderate SF efficiency but, relative to normal spirals, a lower integrated SFR in the past. Because the SF activity in these systems is spread throughout their extended disks, they have overall lower SFR surface densities and lower surface brightness in the optical bands. Relative to normal disk galaxies, the majority of HIghMass galaxies have higher Hα equivalent widths and are bluer in their outer disks, implying an inside-out disk growth scenario. Downbending double exponential disks are more frequent than upbending disks among the gas-rich galaxies, suggesting that SF thresholds exist in the downbending disks, probably as a result of concentrated gas distribution.

  9. Incidental finding of an extensive oropharyngeal mass in magnetic resonance imaging of a patient with temporomandibular disorder: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Omolehinwa, Temitope T.; Mupparapu, Mel; Akintoye, SundayO. [Dept. of Oral Medicine, School of Dental Medicine, University of Pennsylvania, Philadelphia (United States)

    2016-12-15

    In this report, we describe the incidental finding of an oropharyngeal mass in a patient who presented with a chief complaint of temporomandibular pain. The patient was initially evaluated by an otorhinolaryngologist for complaints of headaches, earache, and sinus congestion. Due to worsening headaches and trismus, he was further referred for the management of temporomandibular disorder. The clinical evaluation was uneventful except for limited mouth opening (trismus). An advanced radiological evaluation using magnetic resonance imaging revealed a mass in the nasopharyngeal/oropharyngeal region. The mass occupied the masticatory space and extended superioinferiorly from the skull base to the mandible. A diagnostic biopsy of the lesion revealed a long-standing human papilloma virus (HPV-16)-positive squamous cell carcinoma of the oropharynx. This case illustrates the need for the timely radiological evaluation of seemingly innocuous orofacial pain.

  10. Incidental finding of an extensive oropharyngeal mass in magnetic resonance imaging of a patient with temporomandibular disorder: A case report

    International Nuclear Information System (INIS)

    Omolehinwa, Temitope T.; Mupparapu, Mel; Akintoye, SundayO.

    2016-01-01

    In this report, we describe the incidental finding of an oropharyngeal mass in a patient who presented with a chief complaint of temporomandibular pain. The patient was initially evaluated by an otorhinolaryngologist for complaints of headaches, earache, and sinus congestion. Due to worsening headaches and trismus, he was further referred for the management of temporomandibular disorder. The clinical evaluation was uneventful except for limited mouth opening (trismus). An advanced radiological evaluation using magnetic resonance imaging revealed a mass in the nasopharyngeal/oropharyngeal region. The mass occupied the masticatory space and extended superioinferiorly from the skull base to the mandible. A diagnostic biopsy of the lesion revealed a long-standing human papilloma virus (HPV-16)-positive squamous cell carcinoma of the oropharynx. This case illustrates the need for the timely radiological evaluation of seemingly innocuous orofacial pain

  11. Microscope mode secondary ion mass spectrometry imaging with a Timepix detector.

    NARCIS (Netherlands)

    Kiss, A.; Jungmann, JH; Smith, D.F.; Heeren, R.M.A.

    2013-01-01

    In-vacuum active pixel detectors enable high sensitivity, highly parallel time- and space-resolved detection of ions from complex surfaces. For the first time, a Timepix detector assembly was combined with a secondary ion mass spectrometer for microscope mode secondary ion mass spectrometry (SIMS)

  12. Using matrix peaks to map topography: Increased mass resolution and enhanced sensitivity in chemical imaging

    NARCIS (Netherlands)

    McDonnell, Liam A.; Mize, Todd H.; Luxembourg, Stefan L.; Koster, Sander; Eijkel, Gert B.; Verpoorte, Elisabeth; De Rooij, Nico F.; Heeren, Ron M. A.

    2003-01-01

    It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, in addition to increasing the yield of

  13. Test Sample for the Spatially Resolved Quantification of Illicit Drugs on Fingerprints Using Imaging Mass Spectrometry

    NARCIS (Netherlands)

    Muramoto, S.; Forbes, T.P.; van Asten, A.C.; Gillen, G.

    2015-01-01

    A novel test sample for the spatially resolved quantification of illicit drugs on the surface of a fingerprint using time-of-flight secondary ion mass spectrometry (ToF-SIMS) and desorption electrospray ionization mass spectrometry (DESI-MS) was demonstrated. Calibration curves relating the signal

  14. Reading Contemporary Imaginaries inspired by the Middle Ages Narratives through Mass Media Images

    Directory of Open Access Journals (Sweden)

    Teresa Torres Eça

    2014-11-01

    Full Text Available In this article, the authors will approach images from film and games industry to discuss trends in contemporary young people and young adults’ subcultures. The images will serve as a basis to debate digital natives fascination by metanarratives grounded on stories inspired by Middle Ages stories. A set of images will be discussed through methodologies of visual analysis that may give some insights about the fascination transmitted by medieval stories to young people and young adults’ subcultures.

  15. Intraventricular mass lesions at magnetic resonance imaging: iconographic essay - part 2

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Felipe Damasio de; Reis, Fabiano; Guerra, Jose Guilherme Giocondo, E-mail: fdamasiocastro@gmail.com [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil)

    2014-07-15

    The present essay is illustrated with magnetic resonance images obtained at the authors’ institution over the past 15 years and discusses the main imaging findings of intraventricular tumor-like lesions (colloid cyst, oligodendroglioma, astroblastoma, lipoma, cavernoma) and of inflammatory/infectious lesions (neurocysticercosis and an atypical presentation of neurohistoplasmosis). Such lesions represent a subgroup of intracranial lesions with unique characteristics and some imaging patterns that may facilitate the differential diagnosis. (author)

  16. Identification of Low Coronal Sources of “Stealth” Coronal Mass Ejections Using New Image Processing Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Alzate, Nathalia; Morgan, Huw, E-mail: naa19@aber.ac.uk [Institute of Mathematics, Physics and Computer Science Prifysgol Aberystwyth Ceredigion, Cymru SY23 3BZ (United Kingdom)

    2017-05-10

    Coronal mass ejections (CMEs) are generally associated with low coronal signatures (LCSs), such as flares, filament eruptions, extreme ultraviolet (EUV) waves, or jets. A number of recent studies have reported the existence of stealth CMEs as events without LCSs, possibly due to observational limitations. Our study focuses on a set of 40 stealth CMEs identified from a study by D’Huys et al. New image processing techniques are applied to high-cadence, multi-instrument sets of images spanning the onset and propagation time of each of these CMEs to search for possible LCSs. Twenty-three of these events are identified as small, low-mass, unstructured blobs or puffs, often occurring in the aftermath of a large CME, but associated with LCSs such as small flares, jets, or filament eruptions. Of the larger CMEs, seven are associated with jets and eight with filament eruptions. Several of these filament eruptions are different from the standard model of an erupting filament/flux tube in that they are eruptions of large, faint flux tubes that seem to exist at large heights for a long time prior to their slow eruption. For two of these events, we see an eruption in Large Angle Spectrometric Coronagraph C2 images and the consequent changes at the bottom edge of the eruption in EUV images. All 40 events in our study are associated with some form of LCS. We conclude that stealth CMEs arise from observational and processing limitations.

  17. Hard-copy versus soft-copy with and without simple image manipulation for detection of pulmonary nodules and masses

    International Nuclear Information System (INIS)

    Kosuda, S.; Kaji, T.; Iwasaki, Y.; Kusano, S.; Kobayashi, H.; Watanabe, M.

    2000-01-01

    To compare interpretation performance on soft-copy presentations, with and without simple image manipulation, and on unmodified hard-copy presentations with regard to detection of pulmonary nodules and masses. Material and Methods: Fifty chest digital radiograph combinations of patients with a total of 60 nodules, 32 of which were 2.0 cm in diameter, were selected for the study. Three readers evaluated three separate image formats: unmodified hard- and soft-copies, and soft-copies with simple image manipulation of lung and mediastinum window settings, and zooming. The screen display was 1600x1200 pixels with 8 bits/pixel. Results: The sensitivity, accuracy, detectability, and Az value of the soft-copy systems were clearly inferior to hard-copy evaluation. The mean Az values were 0.921 for unmodified hard-copy, 0.820 for image-manipulated soft-copy, and 0.781 for unmodified soft-copy. Conclusion: Soft-copy interpretations were not as sensitive in detecting pulmonary nodules and masses as hard-copy evaluation

  18. Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation

    Science.gov (United States)

    Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr

    2015-01-01

    Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436

  19. The Chara Array Angular Diameter of HR 8799 Favors Planetary Masses for Its Imaged Companions

    Science.gov (United States)

    2012-12-10

    Strömgren uvby magni- tudes, and Two Micron All Sky Survey ( 2MASS ) JHK mag- nitudes, as published in Crawford et al. (1966), Breger (1968), Eggen (1968...2003), and Olsen (1983, 1993, 1994). Table 5 summarizes the adopted magnitudes; the assigned uncertainties for the 2MASS infrared measurements 9 We...Burrows, A., Itoh, Y., et al. 2011, ApJ, 729, 128 Cutri, R. M., Skurtskie, M. F., van Dyk, S., et al. 2003, The IRSA 2MASS All-Sky Point Source

  20. Arterial spin labeling MR imaging for characterisation of renal masses in patients with impaired renal function: initial experience

    International Nuclear Information System (INIS)

    Pedrosa, Ivan; Rafatzand, Khashayar; Robson, Philip; Alsop, David C.; Wagner, Andrew A.; Atkins, Michael B.; Rofsky, Neil M.

    2012-01-01

    To retrospectively evaluate the feasibility of arterial spin labeling (ASL) magnetic resonance imaging (MRI) for the assessment of vascularity of renal masses in patients with impaired renal function. Between May 2007 and November 2008, 11/67 consecutive patients referred for MRI evaluation of a renal mass underwent unenhanced ASL-MRI due to moderate-to-severe chronic or acute renal failure. Mean blood flow in vascularised and non-vascularised lesions and the relation between blood flow and final diagnosis of malignancy were correlated with a 2-sided homogeneous variance t-test and the Fisher Exact Test, respectively. A p value 2 (range 7-39). The average blood flow of 11 renal masses interpreted as ASL-positive (134 +/- 85.7 mL/100 g/min) was higher than that of 6 renal masses interpreted as ASL-negative (20.5 +/- 8.1 mL/100 g/min)(p = 0.015). ASL-positivity correlated with malignancy (n = 3) or epithelial atypia (n = 1) at histopathology or progression at follow up (n = 7). ASL detection of vascularity in renal masses in patients with impaired renal function is feasible and seems to indicate neoplasia although the technique requires further evaluation. (orig.)

  1. Arterial spin labeling MR imaging for characterisation of renal masses in patients with impaired renal function: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, Ivan [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Rafatzand, Khashayar; Robson, Philip; Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); Wagner, Andrew A. [Beth Israel Deaconess Medical Center and Harvard Medical School, Surgery, Division of Urology, Boston, MA (United States); Atkins, Michael B. [Beth Israel Deaconess Medical Center and Harvard Medical School, Hematology/Oncology, Boston, MA (United States); Rofsky, Neil M. [University of Texas Southwestern Medical Center, Departments of Radiology, Dallas, TX (United States)

    2012-02-15

    To retrospectively evaluate the feasibility of arterial spin labeling (ASL) magnetic resonance imaging (MRI) for the assessment of vascularity of renal masses in patients with impaired renal function. Between May 2007 and November 2008, 11/67 consecutive patients referred for MRI evaluation of a renal mass underwent unenhanced ASL-MRI due to moderate-to-severe chronic or acute renal failure. Mean blood flow in vascularised and non-vascularised lesions and the relation between blood flow and final diagnosis of malignancy were correlated with a 2-sided homogeneous variance t-test and the Fisher Exact Test, respectively. A p value <0.05 was considered statistically significant. Seventeen renal lesions were evaluated in 11 patients (8 male; mean age = 70 years) (range 57-86). The median eGFR was 24 mL/min/1.73 m{sup 2} (range 7-39). The average blood flow of 11 renal masses interpreted as ASL-positive (134 +/- 85.7 mL/100 g/min) was higher than that of 6 renal masses interpreted as ASL-negative (20.5 +/- 8.1 mL/100 g/min)(p = 0.015). ASL-positivity correlated with malignancy (n = 3) or epithelial atypia (n = 1) at histopathology or progression at follow up (n = 7). ASL detection of vascularity in renal masses in patients with impaired renal function is feasible and seems to indicate neoplasia although the technique requires further evaluation. (orig.)

  2. Development and application of a channelized Hotelling observer for DBT optimization on structured background test images with mass simulating targets

    Science.gov (United States)

    Petrov, Dimitar; Michielsen, Koen; Cockmartin, Lesley; Zhang, Gouzhi; Young, Kenneth; Marshall, Nicholas; Bosmans, Hilde

    2016-03-01

    Digital breast tomosynthesis (DBT) is a 3D mammography technique that promises better visualization of low contrast lesions than conventional 2D mammography. A wide range of parameters influence the diagnostic information in DBT images and a systematic means of DBT system optimization is needed. The gold standard for image quality assessment is to perform a human observer experiment with experienced readers. Using human observers for optimization is time consuming and not feasible for the large parameter space of DBT. Our goal was to develop a model observer (MO) that can predict human reading performance for standard detection tasks of target objects within a structured phantom and subsequently apply it in a first comparative study. The phantom consists of an acrylic semi-cylindrical container with acrylic spheres of different sizes and the remaining space filled with water. Three types of lesions were included: 3D printed spiculated and non-spiculated mass lesions along with calcification groups. The images of the two mass lesion types were reconstructed with 3 different reconstruction methods (FBP, FBP with SRSAR, MLTRpr) and read by human readers. A Channelized Hotelling model observer was created for the non-spiculated lesion detection task using five Laguerre-Gauss channels, tuned for better performance. For the non-spiculated mass lesions a linear relation between the MO and human observer results was found, with correlation coefficients of 0.956 for standard FBP, 0.998 for FBP with SRSAR and 0.940 for MLTRpr. Both the MO and human observer percentage correct results for the spiculated masses were close to 100%, and showed no difference from each other for every reconstruction algorithm.

  3. Monitoring Toxic Ionic Liquids in Zebrafish ( Danio rerio) with Desorption Electrospray Ionization Mass Spectrometry Imaging (DESI-MSI)

    Science.gov (United States)

    Perez, Consuelo J.; Tata, Alessandra; de Campos, Michel L.; Peng, Chun; Ifa, Demian R.

    2017-06-01

    Ambient mass spectrometry imaging has become an increasingly powerful technique for the direct analysis of biological tissues in the open environment with minimal sample preparation and fast analysis times. In this study, we introduce desorption electrospray ionization mass spectrometry imaging (DESI-MSI) as a novel, rapid, and sensitive approach to localize the accumulation of a mildly toxic ionic liquid (IL), AMMOENG 130 in zebrafish ( Danio rerio). The work demonstrates that DESI-MSI has the potential to rapidly monitor the accumulation of IL pollutants in aquatic organisms. AMMOENG 130 is a quaternary ammonium-based IL reported to be broadly used as a surfactant in commercialized detergents. It is known to exhibit acute toxicity to zebrafish causing extensive damage to gill secondary lamellae and increasing membrane permeability. Zebrafish were exposed to the IL in a static 96-h exposure study in concentrations near the LC50 of 1.25, 2.5, and 5.0 mg/L. DESI-MS analysis of zebrafish gills demonstrated the appearance of a dealkylated AMMOENG 130 metabolite in the lowest concentration of exposure identified by a high resolution hybrid LTQ-Orbitrap mass spectrometer as the trimethylstearylammonium ion, [C21H46N]+. With DESI-MSI, the accumulation of AMMOENG 130 and its dealkylated metabolite in zebrafish tissue was found in the nervous and respiratory systems. AMMOENG 130 and the metabolite were capable of penetrating the blood brain barrier of the fish with significant accumulation in the brain. Hence, we report for the first time the simultaneous characterization, distribution, and metabolism of a toxic IL in whole body zebrafish analyzed by DESI-MSI. This ambient mass spectrometry imaging technique shows great promise for the direct analysis of biological tissues to qualitatively monitor foreign, toxic, and persistent compounds in aquatic organisms from the environment. [Figure not available: see fulltext.

  4. Ambient ionization mass spectrometry imaging for characterizing plant-microbe interactions using liquid extraction surface analysis (LESA)

    Science.gov (United States)

    Chu, R. K.; Anderton, C.; Weston, D. J.; Carrell, A. A.; Paša-Tolić, L.; Veličković, D.; Tfaily, M.

    2017-12-01

    The rhizosphere consists of a diverse community of plants, bacteria and fungi that are interacting with each other and with complex soil matrix they occupy. By studying the chemical signaling and processes that occur within this dynamic microenvironment, we will further our understanding of the symbiotic and competitive interaction within microbial communities. Field studies and bulk analyses shed light on the mechanisms by which environmental perturbations alter carbon and nitrogen cycling, but what is less clear are the intra- and interspecies molecular transformations and transactions between the different constituents within the rhizosphere. Chemical imaging by liquid extraction surface analysis mass spectrometry (LESA-MS) is a highly sensitive technique capable of providing both spatial and molecular information. Here, we examined the chemical interactions among a tripartite system of peat moss (Sphagnum fallax), cyanobacteria (Nostoc muscorium), and fungus (Trizdiaspa). We coupled LESA source to both a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS), for ultrahigh mass resolution and mass accuracy results, and a Thermo Velos-LTQ mass spectrometer, for tandem MS of selected molecules to increase confidence in molecular identifications. With LESA-MS approach we spatially probed the tripartite interactions and isolated cultures using a coordinate system that can be mapped back and overlaid onto the original image. Using this method, we mapped an array of metabolic distributions within the model sphagnum microbiome. For instance, we identified carbendazim, an anti-fungal agent, distributed within the interaction zone between the bacteria and fungi, while glyceropcholine and sucrose were localized within the sphagnum and fungus interaction zone. Further analysis will look into larger metabolites, lipids, and small proteins.

  5. SPECKLE IMAGING EXCLUDES LOW-MASS COMPANIONS ORBITING THE EXOPLANET HOST STAR TRAPPIST-1

    Energy Technology Data Exchange (ETDEWEB)

    Howell, Steve B.; Scott, Nicholas J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Everett, Mark E. [National Optical Astronomy Observatory, 950 N. Cherry Avenue, Tucson, AZ 85719 (United States); Horch, Elliott P. [Department of Physics, Southern Connecticut State University, 501 Crescent Street, New Haven, CT, 06515 (United States); Winters, Jennifer G. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA, 02138 (United States); Hirsch, Lea [Astronomy Department, University of California, Berkeley, 510 Campbell Hall, Berkeley, CA, 94720 (United States); Nusdeo, Dan [Department of Physics and Astronomy, Georgia State University, P.O. Box 5060, Atlanta, GA 30302 (United States)

    2016-09-20

    We have obtained the highest-resolution images available of TRAPPIST-1 using the Gemini-South telescope and our speckle imaging camera. Observing at 692 and 883 nm, we reached the diffraction limit of the telescope providing a best resolution of 27 mas or, at the distance of TRAPPIST-1, a spatial resolution of 0.32 au. Our imaging of the star extends from 0.32 to 14.5 au. We show that to a high confidence level, we can exclude all possible stellar and brown dwarf companions, indicating that TRAPPIST-1 is a single star.

  6. SPECKLE IMAGING EXCLUDES LOW-MASS COMPANIONS ORBITING THE EXOPLANET HOST STAR TRAPPIST-1

    International Nuclear Information System (INIS)

    Howell, Steve B.; Scott, Nicholas J.; Everett, Mark E.; Horch, Elliott P.; Winters, Jennifer G.; Hirsch, Lea; Nusdeo, Dan

    2016-01-01

    We have obtained the highest-resolution images available of TRAPPIST-1 using the Gemini-South telescope and our speckle imaging camera. Observing at 692 and 883 nm, we reached the diffraction limit of the telescope providing a best resolution of 27 mas or, at the distance of TRAPPIST-1, a spatial resolution of 0.32 au. Our imaging of the star extends from 0.32 to 14.5 au. We show that to a high confidence level, we can exclude all possible stellar and brown dwarf companions, indicating that TRAPPIST-1 is a single star.

  7. Self-compassion moderates the relationship between body mass index and both eating disorder pathology and body image flexibility.

    Science.gov (United States)

    Kelly, Allison C; Vimalakanthan, Kiruthiha; Miller, Kathryn E

    2014-09-01

    The current study examined whether self-compassion, the tendency to treat oneself kindly during distress and disappointments, would attenuate the positive relationship between body mass index (BMI) and eating disorder pathology, and the negative relationship between BMI and body image flexibility. One-hundred and fifty-three female undergraduate students completed measures of self-compassion, self-esteem, eating disorder pathology, and body image flexibility, which refers to one's acceptance of negative body image experiences. Controlling for self-esteem, hierarchical regressions revealed that self-compassion moderated the relationships between BMI and the criteria. Specifically, the positive relationship between BMI and eating disorder pathology and the negative relationship between BMI and body image flexibility were weaker the higher women's levels of self-compassion. Among young women, self-compassion may help to protect against the greater eating disturbances that coincide with a higher BMI, and may facilitate the positive body image experiences that tend to be lower the higher one's BMI. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Perceived Body Image, Eating Behavior, and Sedentary Activities and Body Mass Index Categories in Kuwaiti Female Adolescents

    Directory of Open Access Journals (Sweden)

    Lemia H. Shaban

    2016-01-01

    Full Text Available Background. The State of Kuwait has a growing obesity epidemic in both genders and all age groups; however, obesity rates in the young seem to be rising. Methods. We conducted a cross-sectional survey in 169 Kuwaiti female adolescents attending both private and public schools spanning the six governorates in the State of Kuwait in order to explore female adolescents’ self-image, body dissatisfaction, type of school (private versus public, TV viewing, and computer games and their relationship to body mass index. Results. Approximately half the students classified as obese perceived their body image to lie in the normal range. Females in the obese category were the most dissatisfied with their body image, followed by those in the overweight category. Eating behavior, level of physical activity, school type, television viewing, computer/video usage, and desired BMI were not significantly associated with level of obesity. Conclusion. This study was one of the few studies to assess adolescent females’ body image dissatisfaction in relation to obesity in the State of Kuwait. The results suggest that including body image dissatisfaction awareness into obesity prevention programs would be of value.

  9. Discovery of a Probable 4-5 Jupiter-mass Exoplanet to HD 95086 by Direct Imaging

    Science.gov (United States)

    Rameau, J.; Chauvin, G.; Lagrange, A.-M.; Boccaletti, A.; Quanz, S. P.; Bonnefoy, M.; Girard, J. H.; Delorme, P.; Desidera, S.; Klahr, H.; Mordasini, C.; Dumas, C.; Bonavita, M.

    2013-08-01

    Direct imaging has only begun to inventory the population of gas giant planets on wide orbits around young stars in the solar neighborhood. Following this approach, we carried out a deep imaging survey in the near-infrared using VLT/NaCo to search for substellar companions. Here we report the discovery of a probable companion orbiting the young (10-17 Myr), dusty, early-type (A8) star HD 95086 at 56 AU in L' (3.8 μm) images. This discovery is based on observations with more than a year time lapse. Our first epoch clearly revealed the source at ~= 10σ, while our second epoch lacks good observing conditions, yielding a ~= 3σ detection. Various tests were thus made to rule out possible artifacts. This recovery is consistent with the signal at the first epoch but requires cleaner confirmation. Nevertheless, our astrometric precision suggests that the companion is comoving with the star with a 3σ confidence level. The planetary nature of the source is reinforced by a non-detection in the Ks-band (2.18 μm) images according to its possible extremely red Ks-L' color. Conversely, background contamination is rejected with good confidence level. The luminosity yields a predicted mass of about 4-5 M Jup (at 10-17 Myr) using "hot-start" evolutionary models, making HD 95086 b the exoplanet with the lowest mass ever imaged around a star. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile, under program Nos. 087.C-0292, 088.C.0085, 090.C-0538, 090.C-0698, and 090.C-0728.

  10. Characterisation of a smartphone image sensor response to direct solar 305nm irradiation at high air masses.

    Science.gov (United States)

    Igoe, D P; Amar, A; Parisi, A V; Turner, J

    2017-06-01

    This research reports the first time the sensitivity, properties and response of a smartphone image sensor that has been used to characterise the photobiologically important direct UVB solar irradiances at 305nm in clear sky conditions at high air masses. Solar images taken from Autumn to Spring were analysed using a custom Python script, written to develop and apply an adaptive threshold to mitigate the effects of both noise and hot-pixel aberrations in the images. The images were taken in an unobstructed area, observing from a solar zenith angle as high as 84° (air mass=9.6) to local solar maximum (up to a solar zenith angle of 23°) to fully develop the calibration model in temperatures that varied from 2°C to 24°C. The mean ozone thickness throughout all observations was 281±18 DU (to 2 standard deviations). A Langley Plot was used to confirm that there were constant atmospheric conditions throughout the observations. The quadratic calibration model developed has a strong correlation between the red colour channel from the smartphone with the Microtops measurements of the direct sun 305nm UV, with a coefficient of determination of 0.998 and very low standard errors. Validation of the model verified the robustness of the method and the model, with an average discrepancy of only 5% between smartphone derived and Microtops observed direct solar irradiances at 305nm. The results demonstrate the effectiveness of using the smartphone image sensor as a means to measure photobiologically important solar UVB radiation. The use of ubiquitous portable technologies, such as smartphones and laptop computers to perform data collection and analysis of solar UVB observations is an example of how scientific investigations can be performed by citizen science based individuals and groups, communities and schools. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Optimization of Tomosynthesis Imaging for Improved Mass and Microcalcification Detection in the Breast

    National Research Council Canada - National Science Library

    Xia, Dan

    2008-01-01

    The goal of this research is to obtain systematic understandings of the effects of various physical factors that are important in breast tomosynthesis imaging and to develop techniques for effectively...

  12. Direct imaging of plant metabolites in leaves and petals by Desorption Electrospray Ionization mass spectrometry

    DEFF Research Database (Denmark)

    Li, Bin; Hansen, Steen Honore'; Janfelt, Christian

    2013-01-01

    and demonstrated on leaves and petals of Hypericum perforatum. The direct imaging approaches are in contrast to previous DESI imaging studies where indirect analysis via imprints were used in order to overcome the morphological barrier presented by the layer of cuticular waxes covering the surface of a leaf...... of very long chain fatty acids (VLCFAs), a significant class of metabolites located in the cuticle layer in leaves and petals, as well as other plant metabolites. In the case of the petals of H. perforatum, all common metabolites could be imaged directly using the ternary solvent, whereas in the case...... of leaves from the same plant, only some of the metabolites were accessible, even with the ternary solvent system. For these samples, the leaves could be imaged with direct DESI after chloroform had been used to remove most of the cuticle, thus exposing lower layers in the leaf structure. A number...

  13. Magnetic resonance imaging as a diagnostic tool in case of ovarian masses in girls and young women.

    Science.gov (United States)

    Bekiesińska-Figatowska, Monika; Jurkiewicz, Elzbieta; Iwanowska, Beata; Uliasz, Maria; Romaniuk-Doroszewska, Anna; Bragoszewska, Hanna; Ceran, Alicja; Olszewski, Andrzej

    2007-05-01

    Gynecological examination and transvaginal ultrasound are difficult or impossible in girls and young women who have not started their sexual life. CT is not a method of choice in this age group because of the ionizing radiation and iodine-containing contrast media. MRI is chosen then. Pelvic MRI was performed in 15 patients aged 9-19 years with suspected ovarian mass after they had had unclear gynecological and sonographic examinations. 1.5 T MRI systems were used. SE,T(F)SE and SPIR sequences were applied in T1- and T2-weighted images in three planes. Contrast media were administered in 7 patients. In a group of 3 girls with acute abdominal pain, polycystic ovaries, ovarian hemorrhagic cyst, and fibroma of the ovary were diagnosed. In a group of 11 patients with chronic abdominal pain, dermoid cysts of the ovaries were found in 7 cases, in one bilateral and accompanied by ectopic kidney. In 2 patients, serous cysts were diagnosed. In 2 cases an ovarian origin of the mass was excluded: multilocular cystic lesion in the presacral region and a hydatid mole were revealed. A neoplastic ovarian mass was diagnosed in a girl with increasing circumference of the abdomen. The accuracy of MRI in localizing lesions was 100%. Its accuracy in precisely characterizing lesions was 83.3%. Magnetic resonance imaging, with its noninvasiveness, high spatial resolution, and tissue specificity, is a method of choice in the diagnosis or exclusion of ovarian pathology in children and adolescents.

  14. High-Contrast 3.8 Micron Imaging of the Brown Dwarf/Planet-Mass Companion to GJ 758

    Science.gov (United States)

    Currie, Thayne M.; Bailey, Vanessa; Fabrycky, Daniel; Murray-Clay, Ruth; Rodigas, Timothy; Hinz, Phil

    2011-01-01

    We present L' band (3.8 Micron) MMT/Clio high-contrast imaging data for the nearby star GJ 758, which was recently reported by Thalmann et al. (2009) to have one - possibly two - faint comoving companions (GJ 7588 and "C", respectively). GJ 758B is detected in two distinct datasets. Additionally, we report a \\textit{possible} detection of the object identified by Thalmann et al as "GJ 758C" in our more sensitive dataset, though it is likely a residual speckle. However, if it is the same object as that reported by Thalmann et al. it cannot be a companion in a bound orbit. GJ 7588 has a H-L' color redder than nearly all known L-T8 dwarfs. 8ased on comparisons with the COND evolutionary models, GJ 7588 has Te approx. 560 K (+150 K, -90 K) and a mass ranging from approx.10-20 Mj if it is approx.1 Gyr old to approx. 25-40 Mj if it is 8.7 Gyr old. GJ 7588 is likely in a highly eccentric orbit, e approx. 0.73 (+0.12,-0.21), with a semimajor axis of approx. 44 AU (+32 AU, -14 AU). Though GJ 7588 is sometimes discussed within the context of exoplanet direct imaging, its mass is likely greater than the deuterium-burning limit and its formation may resemble that of binary stars rather than that of jovian-mass planets.

  15. Comparison of Body Image and its Relationship with Body Mass Index (BMI in High School Students of Ahvaz, Iran

    Directory of Open Access Journals (Sweden)

    Mahsa Behdarvandi

    2017-02-01

    Full Text Available BackgroundIt is not clearly specified that which of the components of body mass index (BMI affect body image and which of them do not. Given that having information in this regard is of special importance as a basis for future planning for adolescents, the present research aimed to compare body image in female and male adolescents and study its relationship with body mass index in high school students of Ahwaz, Khuzestan Province in the academic year 2015-2016.Materials and MethodsIn this descriptive-analytic study, 200 high school students were selected as the sample using the random cluster sampling method. The required data were collected using demographic questionnaire, anthropometric data checklist (height and weight, and the Multidimensional Body-Self Relations Questionnaire (MBSRQ. All descriptive and inferential statistics tests were performed using SPSS-17 at a confidence level of 95%.Results: The students ranged from 15 to 18 years old. Equal distribution was employed among all four grades of high school. Body mass index (BMI in male students showed a significant inverse relationship only with appearance orientation (P

  16. CHARACTERIZING THE STAR FORMATION OF THE LOW-MASS SHIELD GALAXIES FROM HUBBLE SPACE TELESCOPE IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    McQuinn, Kristen B. W.; Skillman, Evan D.; Simones, Jacob E. [Minnesota Institute for Astrophysics, School of Physics and Astronomy, University of Minnesota, 116 Church Street, S.E., Minneapolis, MN 55455 (United States); Cannon, John M. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Dolphin, Andrew E. [Raytheon Company, 1151 E. Hermans Road, Tucson, AZ 85756 (United States); Haynes, Martha P.; Giovanelli, Riccardo [Center for Radiophysics and Space Research, Space Sciences Building, Cornell University, Ithaca, NY 14853 (United States); Salzer, John J. [Department of Astronomy, Indiana University, 727 East 3rd Street, Bloomington, IN 47405 (United States); Adams, Elizabeth A. K. [Netherlands Institute for Radio Astronomy (ASTRON), Postbus 2, 7900 AA Dwingeloo (Netherlands); Elson, Ed C. [Astrophysics, Cosmology and Gravity Centre (ACGC), Department of Astronomy, University of Cape Town, Private Bag X3, Rondebosch 7701 (South Africa); Ott, Jürgen, E-mail: kmcquinn@astro.umn.edu [National Radio Astronomy Observatory, P.O. Box O, 1003 Lopezville Road, Socorro, NM 87801 (United States)

    2015-03-20

    The Survey of Hi in Extremely Low-mass Dwarfs is an on-going multi-wavelength program to characterize the gas, star formation, and evolution in gas-rich, very low-mass galaxies that populate the faint end of the galaxy luminosity function. The galaxies were selected from the first ∼10% of the Hi Arecibo Legacy Fast ALFA survey based on their low Hi mass and low baryonic mass. Here, we measure the star formation properties from optically resolved stellar populations for 12 galaxies using a color–magnitude diagram fitting technique. We derive lifetime average star formation rates (SFRs), recent SFRs, stellar masses, and gas fractions. Overall, the recent SFRs are comparable to the lifetime SFRs with mean birthrate parameter of 1.4, with a surprisingly narrow standard deviation of 0.7. Two galaxies are classified as dwarf transition galaxies (dTrans). These dTrans systems have star formation and gas properties consistent with the rest of the sample, in agreement with previous results that some dTrans galaxies may simply be low-luminosity dwarf irregulars. We do not find a correlation between the recent star formation activity and the distance to the nearest neighboring galaxy, suggesting that the star formation process is not driven by gravitational interactions, but regulated internally. Further, we find a broadening in the star formation and gas properties (i.e., specific SFRs, stellar masses, and gas fractions) compared to the generally tight correlation found in more massive galaxies. Overall, the star formation and gas properties indicate these very low-mass galaxies host a fluctuating, non-deterministic, and inefficient star formation process.

  17. Subependymal Heterotopia Mimicking Mass in Conventional Magnetic Resonance Imaging: Demonstration With 3T Advanced Neuroimages.

    Science.gov (United States)

    Aktas, Filiz; Ogul, Hayri

    2017-10-01

    The authors reported a rare patient with large subependymal heterotopia mimicking cerebral neoplasia. A 22-year-old female was admitted with a history of right-sided paresthesia accompanied by progressive headache. Cerebral magnetic resonance (MR) imaging showed a large solid lesion in the left frontal lobe. Advanced MR images proved that the lesion was compatible with subependymal heterotopia. Large subependymal heterotopia may mimick cerebral neoplasia.

  18. Can masses of non-experts train highly accurate image classifiers? A crowdsourcing approach to instrument segmentation in laparoscopic images.

    Science.gov (United States)

    Maier-Hein, Lena; Mersmann, Sven; Kondermann, Daniel; Bodenstedt, Sebastian; Sanchez, Alexandro; Stock, Christian; Kenngott, Hannes Gotz; Eisenmann, Mathias; Speidel, Stefanie

    2014-01-01

    Machine learning algorithms are gaining increasing interest in the context of computer-assisted interventions. One of the bottlenecks so far, however, has been the availability of training data, typically generated by medical experts with very limited resources. Crowdsourcing is a new trend that is based on outsourcing cognitive tasks to many anonymous untrained individuals from an online community. In this work, we investigate the potential of crowdsourcing for segmenting medical instruments in endoscopic image data. Our study suggests that (1) segmentations computed from annotations of multiple anonymous non-experts are comparable to those made by medical experts and (2) training data generated by the crowd is of the same quality as that annotated by medical experts. Given the speed of annotation, scalability and low costs, this implies that the scientific community might no longer need to rely on experts to generate reference or training data for certain applications. To trigger further research in endoscopic image processing, the data used in this study will be made publicly available.

  19. K{sub α} x-ray imaging of laser-irradiated, limited-mass zirconium foils

    Energy Technology Data Exchange (ETDEWEB)

    Storm, M.; Orban, C.; Jiang, S.; Freeman, R. R.; Akli, K. [Department of Physics, The Ohio State University, 191 West Woodruff Road, Columbus, Ohio 43210 (United States); Eichman, B.; Fiksel, G.; Stoeckl, C.; Theobald, W.; Delettrez, J. A. [The Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Dyer, G.; Ditmire, T. [The Texas Center of High Energy Density Science, The University of Texas at Austin, 2511 Speedway Street, Austin, Texas 78712 (United States); Stephens, R. [General Atomics, 3550 General Atomics Court, San Diego, California 92121-1200 (United States)

    2014-07-15

    X-ray fluorescence measurements to determine the effect of target heating on imaging efficiency, at a photon energy of 15.7 keV corresponding to the K{sub α} line of zirconium, have been carried out using limited-mass foils irradiated by the Texas Petawatt Laser. Zirconium foils that ranged in volume from 3000 × 3000 × 21 μm{sup 3} to 150 × 150 × 6 μm{sup 3} were irradiated with 100 J, 8 ps-long pulses and a mean intensity of 4 × 10{sup 19} W/cm{sup 2}. The K{sub α} emission was measured simultaneously using a highly ordered pyrolytic graphite crystal spectrometer and a curved quartz imaging crystal. The measured ratio of the integrated image signal to the integrated spectral signal was, within the experimental error, constant, indicating that the imaging efficiency's dependence on temperature is weak throughout the probed range. Based on our experience of target heating under similar conditions, we estimate a temperature of ∼200 eV for the smallest targets. The successful imaging of K{sub α} emission for temperatures this high represents an important proof of concept for Zr K{sub α} imaging. At these temperatures, the imaging of K{sub α} emission from lower-Z materials (such as Cu) is limited by temperature-dependent shifts in the K{sub α} emission energy.

  20. A new standard of visual data representation for imaging mass spectrometry.

    Science.gov (United States)

    O'Rourke, Matthew B; Padula, Matthew P

    2017-03-01

    MALDI imaging MS (IMS) is principally used for cancer diagnostics. In our own experience with publishing IMS data, we have been requested to modify our protocols with respect to the areas of the tissue that are imaged in order to comply with the wider literature. In light of this, we have determined that current methodologies lack effective controls and can potentially introduce bias by only imaging specific areas of the targeted tissue EXPERIMENTAL DESIGN: A previously imaged sample was selected and then cropped in different ways to show the potential effect of only imaging targeted areas. By using a model sample, we were able to effectively show how selective imaging of samples can misinterpret tissue features and by changing the areas that are acquired, according to our new standard, an effective internal control can be introduced. Current IMS sampling convention relies on the assumption that sample preparation has been performed correctly. This prevents users from checking whether molecules have moved beyond borders of the tissue due to delocalization and consequentially products of improper sample preparation could be interpreted as biological features that are of critical importance when encountered in a visual diagnostic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. In-source collision induced dissociation of inorganic explosives for mass spectrometric signature detection and chemical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Forbes, Thomas P., E-mail: thomas.forbes@nist.gov; Sisco, Edward

    2015-09-10

    The trace detection, bulk quantification, and chemical imaging of inorganic explosives and components was demonstrated utilizing in-source collision induced dissociation (CID) coupled with laser desorption/ionization mass spectrometry (LDI-MS). The incorporation of in-source CID provided direct control over the extent of adduct and cluster fragmentation as well as organic noise reduction for the enhanced detection of both the elemental and molecular ion signatures of fuel-oxidizer mixtures and other inorganic components of explosive devices. Investigation of oxidizer molecular anions, specifically, nitrates, chlorates, and perchlorates, identified that the optimal in-source CID existed at the transition between fragmentation of the ionic salt bonds and molecular anion bonds. The chemical imaging of oxidizer particles from latent fingerprints was demonstrated, including both cation and anion components in positive and negative mode mass spectrometry, respectively. This investigation demonstrated LDI-MS with in-source CID as a versatile tool for security fields, as well as environmental monitoring and nuclear safeguards, facilitating the detection of elemental and molecular inorganic compounds at nanogram levels. - Highlights: • In-source CID enhanced detection of elemental inorganics up to 1000-fold. • In-source CID optimization of polyatomic oxidizers enhanced detection up to 100-fold. • Optimal CID identified at transition from breaking ionic salt to molecular anion bonds. • Trace detection of inorganic explosives at nanogram levels was demonstrated. • Oxidizer particles were chemically imaged directly from latent fingerprints.

  2. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy

    International Nuclear Information System (INIS)

    Wirtz, T; Philipp, P; Audinot, J-N; Dowsett, D; Eswara, S

    2015-01-01

    Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM). (paper)

  3. Medical image of the week: right neck mass with thoracic extension

    Directory of Open Access Journals (Sweden)

    Siddiqi TA

    2013-05-01

    Full Text Available A 28-year-old female with a history of chronic pancreatitis s/p total pancreatectomy and auto-islet cell transplantation developed a progressively enlarging right neck mass of 4 weeks duration. Coccidioides IgM antibodies were negative and IgG antibodies were positive by immunoassay (EIA, with titers 1:4 by complement fixation (CF. Fine needle aspiration with subsequent excisional biopsy of the right neck mass was performed and showed reactive lymphoid hyperplasia without fungal elements. Bronchoscopy with right upper lobe endobronchial biopsy and 4R lymph node endobronchial ultrasound-fine needle aspiration revealed granulomatous inflammation and Coccidioides spherules on Gomori's methenamine silver stain. Fungal cultures from the right neck mass fine needle aspiration, endobronchial biopsy, and 4R lymph node grew Coccidioides after three weeks of culture.

  4. Performance of Dental Hygiene Students in Mass Fatality Training and Radiographic Imaging of Dental Remains.

    Science.gov (United States)

    Newcomb, Tara L; Bruhn, Ann M; Ulmer, Loreta H; Diawara, Norou

    2015-10-01

    Mass fatality incidents can overwhelm local, state and national resources quickly. Dental hygienists are widely distributed and have the potential to increase response teams' capacity. However, appropriate training is required. The literature is void of addressing this type of training for dental hygienists and scant in dentistry. Hence, the purpose of this study was to assess one facet of such training: Whether the use of multimedia is likely to enhance educational outcomes related to mass fatality training. A randomized, double-blind, pre- and post-test design was used to evaluate the effectiveness of comparable educational modules for 2 groups: a control group (n=19) that received low media training and a treatment group (n=20) that received multimedia training. Participants were second-year, baccalaureate dental hygiene students. Study instruments included a multiple-choice examination, a clinical competency-based radiology lab scored via a standardized rubric, and an assessment of interest in mass fatality education as a specialty. ANOVA was used to analyze results. Participants' pre- and post-test scores and clinical competency-based radiology lab scores increased following both educational approaches. Interest in mass fatality training also increased significantly for all participants (p=0.45). There was no significant difference in pre- and post-test multiple choice scores (p=0.6455), interest (p=0.9133) or overall competency-based radiology lab scores (p=0.997) between groups. Various educational technique may be effective for mass fatality training. However, mass fatality training that incorporates multimedia is an appropriate avenue for training instruction. Continued research about multimedia's role in this specialty area is encouraged. Copyright © 2015 The American Dental Hygienists’ Association.

  5. Relationship between body mass index and women's body image, self-esteem and eating behaviours in pregnancy: a cross-cultural study.

    Science.gov (United States)

    Shloim, Netalie; Hetherington, Marion M; Rudolf, Mary; Feltbower, Richard G

    2015-04-01

    This study examined the relationship between self-esteem, restrained eating, body image and body mass index during pregnancy. A total of 110 pregnant Israeli and UK women completed the Rosenberg Self-Esteem Questionnaire, the Dutch Eating Behaviour Questionnaire, scales to assess body image and demographics. Body mass index was calculated from antenatal records. Regression modelling determined the relationship between variables, countries and body mass index categories. High correlations were found between body image and body mass index with significantly higher body dissatisfaction for Israeli women. Self-esteem scores for pregnant women were similar to those reported for non-pregnant women. Poorer body image and higher prevalence of restrained eating were found in healthy weight Israeli women. © The Author(s) 2013.

  6. Magnetic resonance imaging of athlete's heart: myocardial mass, left ventricular function, and cross-sectional area of the coronary arteries

    International Nuclear Information System (INIS)

    Zandrino, F.; Sardanelli, F.; Molinari, G.; Masperone, M.A.; Smeraldi, A.; Odaglia, G.

    2000-01-01

    To evaluate left ventricular myocardial mass and function as well as ostial coronary artery cross-sectional area in endurance athletes, an athlete group of 12 highly trained rowers and a control group of 12 sedentary healthy subjects underwent MR examination. An ECG-gated breath-hold cine gradient-echo sequence was used to calculate myocardial mass, end-diastolic and end-systolic volumes, stroke volume, and cardiac output, all related to body surface area, as well as ejection fraction. A 3D fat-saturated ECG- and respiratory-triggered navigator echo sequence was used to evaluate coronary arteries: left main (LM), left anterior descending (LAD), left circumflex (LCx), and right coronary artery (RCA). Cross-sectional area was calculated and divided for body surface area. Myocardial mass was found significantly larger in athlete group than in control group (p = 0.0078), the same being for end-diastolic volume (p = 0.0078), stroke volume (p = 0.0055), LM (p = 0.0066) and LAD (p = 0.0129). No significant difference was found for all the remaining parameters. Significant correlation with myocardial mass was found for LM (p < 0.001) and LAD (p = 0.0340), not for LCx and RCA. Magnetic resonance imaging is a useful tool in evaluating the myocardial hypertrophy and function of athlete's heart. Magnetic resonance angiography is a valuable noninvasive method to visualize the correlated cross-sectional area increase of the left coronary artery system. (orig.)

  7. THE BLACK HOLE MASS-BULGE LUMINOSITY RELATIONSHIP FOR ACTIVE GALACTIC NUCLEI FROM REVERBERATION MAPPING AND HUBBLE SPACE TELESCOPE IMAGING

    International Nuclear Information System (INIS)

    Bentz, Misty C.; Peterson, Bradley M.; Pogge, Richard W.; Vestergaard, Marianne

    2009-01-01

    We investigate the relationship between black hole mass and bulge luminosity for active galactic nuclei (AGNs) with reverberation-based black hole mass measurements and bulge luminosities from two-dimensional decompositions of Hubble Space Telescope host galaxy images. We find that the slope of the relationship for AGNs is 0.76-0.85 with an uncertainty of ∼0.1, somewhat shallower than the M BH ∝ L 1.0±0.1 relationship that has been fit to nearby quiescent galaxies with dynamical black hole mass measurements. This difference is somewhat perplexing, as the AGN black hole masses include an overall scaling factor that brings the AGN M BH -σ * relationship into agreement with that of quiescent galaxies. We discuss biases that may be inherent to the AGN and quiescent galaxy samples and could cause the apparent inconsistency in the forms of their M BH -L bulge relationships. Recent work by Graham, however, presents a similar slope of ∼0.8 for the quiescent galaxies and may bring the relationship for AGNs and quiescent galaxies into agreement.

  8. Improving performance of content-based image retrieval schemes in searching for similar breast mass regions: an assessment

    International Nuclear Information System (INIS)

    Wang Xiaohui; Park, Sang Cheol; Zheng Bin

    2009-01-01

    This study aims to assess three methods commonly used in content-based image retrieval (CBIR) schemes and investigate the approaches to improve scheme performance. A reference database involving 3000 regions of interest (ROIs) was established. Among them, 400 ROIs were randomly selected to form a testing dataset. Three methods, namely mutual information, Pearson's correlation and a multi-feature-based k-nearest neighbor (KNN) algorithm, were applied to search for the 15 'the most similar' reference ROIs to each testing ROI. The clinical relevance and visual similarity of searching results were evaluated using the areas under receiver operating characteristic (ROC) curves (A Z ) and average mean square difference (MSD) of the mass boundary spiculation level ratings between testing and selected ROIs, respectively. The results showed that the A Z values were 0.893 ± 0.009, 0.606 ± 0.021 and 0.699 ± 0.026 for the use of KNN, mutual information and Pearson's correlation, respectively. The A Z values increased to 0.724 ± 0.017 and 0.787 ± 0.016 for mutual information and Pearson's correlation when using ROIs with the size adaptively adjusted based on actual mass size. The corresponding MSD values were 2.107 ± 0.718, 2.301 ± 0.733 and 2.298 ± 0.743. The study demonstrates that due to the diversity of medical images, CBIR schemes using multiple image features and mass size-based ROIs can achieve significantly improved performance.

  9. Aspects of Quantitation in Mass Spectrometry Imaging Investigated on Cryo-Sections of Spiked Tissue Homogenates

    DEFF Research Database (Denmark)

    Hansen, Heidi Toft; Janfelt, Christian

    2016-01-01

    for differences in tissue types in, for example, whole-body imaging, a set of tissue homogenates of different tissue types (lung, liver, kidney, heart, and brain) from rabbit was spiked to the same concentration with the drug amitriptyline and imaged in the same experiment using isotope labeled amitriptyline...... for these results range approximately within a factor of 3 (but for other compounds in other tissues could be higher), underscore the importance of preparing the standard curve in the same matrix as the unknown sample whenever possible. In, for example, whole-body imaging where a diversity of tissue types...... are present, this variation across tissue types will therefore add to the overall uncertainty in quantitation. The tissue homogenates were also used in a characterization of various phenomena in quantitative MSI, such as to study how the signal depends of the thickness of the cryo-section, and to assess...

  10. Time-of-flight mass spectrometer using an imaging detector and a rotating electric field

    International Nuclear Information System (INIS)

    Katayama, Atsushi; Kameo, Yutaka; Nakashima, Mikio

    2008-01-01

    A new technique for minor isotope analysis that uses a rotating electric field and an imaging detector is described. The rotating electric field is generated by six cylindrically arranged plane electrodes with multi-phase sinusoidal wave voltage. When ion packets that are discriminated by time-of-flight enter the rotating electric field, they are circularly deflected, rendering a spiral image on the fluorescent screen of the detector. This spiral image represents m/z values of ions as the position and abundance of ions as brightness. For minor isotopes analyses, the micro channel plate detector under gate control operation is used to eliminate the influence of high intensity of major isotopes. (author)

  11. Protein biomarkers on tissue as imaged via MALDI mass spectrometry: A systematic approach to study the limits of detection.

    Science.gov (United States)

    van de Ven, Stephanie M W Y; Bemis, Kyle D; Lau, Kenneth; Adusumilli, Ravali; Kota, Uma; Stolowitz, Mark; Vitek, Olga; Mallick, Parag; Gambhir, Sanjiv S

    2016-06-01

    MALDI mass spectrometry imaging (MSI) is emerging as a tool for protein and peptide imaging across tissue sections. Despite extensive study, there does not yet exist a baseline study evaluating the potential capabilities for this technique to detect diverse proteins in tissue sections. In this study, we developed a systematic approach for characterizing MALDI-MSI workflows in terms of limits of detection, coefficients of variation, spatial resolution, and the identification of endogenous tissue proteins. Our goal was to quantify these figures of merit for a number of different proteins and peptides, in order to gain more insight in the feasibility of protein biomarker discovery efforts using this technique. Control proteins and peptides were deposited in serial dilutions on thinly sectioned mouse xenograft tissue. Using our experimental setup, coefficients of variation were biomarkers and a new benchmarking strategy that can be used for comparing diverse MALDI-MSI workflows. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Os cuboideum secundarium: A rare accessory ossicle with the potential to mimic a mass on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kauffmann, Gregory; Stacy, G.S.

    2014-01-01

    Accessory ossicles are common incidental findings on radiographs of the ankle and foot. While typically asymptomatic and of no clinical significance, they are sometimes associated with local pain or even mistaken for pathological conditions such as fractures. Given the potential for misinterpretation, it is important to understand their typical locations and appearances. This case highlights an exceptionally rare accessory ossicle called the os cuboideum secundarium, located adjacent to the cuboid and calcaneus. Interestingly, this case demonstrates the potential for this rare ossicle to mimic a mass on magnetic resonance imaging (MRI). Furthermore, despite the significant improvements in the understanding of musculoskeletal pathology afforded by advancements in cross-sectional imaging techniques, this case is a reminder of certain pitfalls that remain. Lastly, it highlights the importance of radiographs as an initial diagnostic study in evaluating foot pain. (orig.)

  13. Levator claviculae muscle presenting as a hard clavicular mass: imaging study

    International Nuclear Information System (INIS)

    Ruiz Santiago, F.; Lopez Milena, G.; Tristan Fernandez, J.M.; Chamorro Santos, C.

    2001-01-01

    We report a case of levator claviculae muscle presenting clinically as a hard mass in the clavicular area due to angular deformity of this bone. To our knowledge, this is the first report where the anomalous muscle shows this clinical presentation. (orig.)

  14. The Relations among Body Image, Physical Attractiveness, and Body Mass in Adolescence.

    Science.gov (United States)

    Rosenblum, Gianine D.; Lewis, Michael

    1999-01-01

    Examined body dissatisfaction, physical attractiveness, and body mass index in adolescents at 13, 15, and 18 years of age. Found that sex differences in body dissatisfaction emerged between 13 and 15 years and were maintained. Girls' body dissatisfaction increased, whereas boys' decreased. Body dissatisfaction was weakly related to others' rating…

  15. Characterization of benign and malignant solid breast masses in harmonic 3D power Doppler imaging

    International Nuclear Information System (INIS)

    Hsiao, Y.-H.; Huang, Y.-L.; Kuo, S.-J.; Liang, W.-M.; Chen, S.-T.; Chen, D.-R.

    2009-01-01

    Purpose: The authors assessed the characteristics of benign and malignant solid breast tumors in harmonic three-dimensional (3D) power Doppler imaging and proposed decision models to classify benign and malignant breast tumors. Materials and methods: A total of 86 malignant and 97 benign harmonic 3D power Doppler US images were analyzed. All the harmonic 3D power Doppler images were obtained using a Voluson730 US system (GE, Zipf, Austria) equipped with a RSP 6-12 transducer and tissue harmonic imaging modalities. Imaging analysis was performed using the Virtual Organ Computer-aided Analysis (VOCAL)-imaging program. Histogram indices, the vascularization index (VI), flow index (FI) and vascularization-flow index (VFI), were calculated for the intra-tumor and for shells with an outside thickness of 3 mm surrounding the breast tumors. The receiver operating characteristic (ROC) curves were calculated to estimate the diagnostic performances. Results: The results revealed that the choice of decision model comprised the parameters of patient age, intra-tumor VI, and tumor volume to classify benign and malignant breast tumors. The area under the ROC curve (Az) was 0.910, accuracy was 81.4%, and sensitivity and specificity were 81.4% and 81.4%, respectively. The parameter intra-tumor VI was the choice for all of the histogram indices in differentiating between malignant and benign lesions. Conclusion: The decision model, which was composed of patient age, tumor volume and intra-tumor VI, and a cut-off value for intra-tumor VI at the upper end of patient age and tumor volume, was recommended in clinical application.

  16. Spatially resolved chemical analysis of cicada wings using laser-ablation electrospray ionization (LAESI) imaging mass spectrometry (IMS).

    Science.gov (United States)

    Román, Jessica K; Walsh, Callee M; Oh, Junho; Dana, Catherine E; Hong, Sungmin; Jo, Kyoo D; Alleyne, Marianne; Miljkovic, Nenad; Cropek, Donald M

    2018-03-01

    Laser-ablation electrospray ionization (LAESI) imaging mass spectrometry (IMS) is an emerging bioanalytical tool for direct imaging and analysis of biological tissues. Performing ionization in an ambient environment, this technique requires little sample preparation and no additional matrix, and can be performed on natural, uneven surfaces. When combined with optical microscopy, the investigation of biological samples by LAESI allows for spatially resolved compositional analysis. We demonstrate here the applicability of LAESI-IMS for the chemical analysis of thin, desiccated biological samples, specifically Neotibicen pruinosus cicada wings. Positive-ion LAESI-IMS accurate ion-map data was acquired from several wing cells and superimposed onto optical images allowing for compositional comparisons across areas of the wing. Various putative chemical identifications were made indicating the presence of hydrocarbons, lipids/esters, amines/amides, and sulfonated/phosphorylated compounds. With the spatial resolution capability, surprising chemical distribution patterns were observed across the cicada wing, which may assist in correlating trends in surface properties with chemical distribution. Observed ions were either (1) equally dispersed across the wing, (2) more concentrated closer to the body of the insect (proximal end), or (3) more concentrated toward the tip of the wing (distal end). These findings demonstrate LAESI-IMS as a tool for the acquisition of spatially resolved chemical information from fragile, dried insect wings. This LAESI-IMS technique has important implications for the study of functional biomaterials, where understanding the correlation between chemical composition, physical structure, and biological function is critical. Graphical abstract Positive-ion laser-ablation electrospray ionization mass spectrometry coupled with optical imaging provides a powerful tool for the spatially resolved chemical analysis of cicada wings.

  17. MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses

    Science.gov (United States)

    Bokhart, Mark T.; Nazari, Milad; Garrard, Kenneth P.; Muddiman, David C.

    2018-01-01

    A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. [Figure not available: see fulltext.

  18. Exposure to slim images in mass media : television commercials as reminders of restriction in restrained eaters

    NARCIS (Netherlands)

    Anschutz, Doeschka J; van Strien, Tatjana; Engels, Rutger C M E

    OBJECTIVE: The aim of the present study was to explore the effects of exposure to slim images and diet-related products in commercials on actual food intake in relation to dietary restraint. DESIGN: An experimental design was used, in which food intake was measured in 124 female students who watched

  19. Focal masses in a non-cirrhotic liver: The additional benefit of CEUS over baseline imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chiorean, L., E-mail: lilichiorean@yahoo.com [Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University (China); Med. Klinik 2, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany); Département d’imagerie médicale, Clinique des Cévennes, 07100 Annonay (France); Cantisani, V., E-mail: vito.cantisani@uniroma1.it [Dipartimento di Scienze Radiologiche, Oncologiche, Anatomo-patologiche, Policlinico Umberto I, Univ. Sapienza, Roma (Italy); Jenssen, C., E-mail: C.Jenssen@khmol.de [Innere Medizin, Krankenhaus Märkisch Oderland, Prötzeler Chaussee 5, 15433 Strausberg (Germany); Sidhu, P.S., E-mail: paulsidhu@nhs.net [Department of Radiology, King' s College Hospital, Denmark Hill, London SE5 9RS, England (United Kingdom); Baum, U., E-mail: Ulrich.Baum@ckbm.de [Department of Radiology, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany); Dietrich, C.F., E-mail: christoph.dietrich@ckbm.de [Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University (China); Med. Klinik 2, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany)

    2015-09-15

    Highlights: • Contrast-enhanced ultrasound in detection of focal liver lesions. • Contrast-enhanced ultrasound in characterization of focal liver lesions. • Contrast-enhanced ultrasound in differential diagnosis of focal liver lesions. • Contrast-enhanced ultrasound in final diagnosis of focal liver lesions. • Contrast-enhanced ultrasound in liver metastases screening. • Roles of cross-sectional imaging techniques for focal liver lesions assessment. • Advantages of contrast-enhanced ultrasound over other imaging procedures. - Abstract: Incidentally detected focal liver lesions are commonly encountered in clinical practice presenting a challenge in the daily department work flow. Guidelines for the management of incidental focal liver lesions have been published but comments, illustrations and recommendations regarding practical issues are crucial. The unique features of contrast-enhanced ultrasound in non-invasive assessment of focal liver lesion enhancement throughout the vascular phases in real-time has allowed an impressive improvement in the diagnostic accuracy of ultrasound. We highlight the additional benefit of contrast-enhanced ultrasound over conventional B-mode ultrasound imaging in detection, characterization, differential and final diagnosis of focal liver lesions, as well as for liver metastases screening. The current roles of cross-sectional imaging are explained in detail, with indications and limitations for each procedure. The advantages of CEUS, such as non-ionizing radiation exposure, cost benefits, non-iodinate contrast agents, and repeatability are also described ultimately improving patient management.

  20. Optimization of Tomosynthesis Imaging for Improved Mass and Microcalcification Detection in the Breast

    Science.gov (United States)

    2009-04-01

    wall to nipple distance, breast thickness, and breast glandularity have been taken into account. We have generated and evaluated scatter components for...tion by use of these algorithms in their discrete forms. As men - tioned above, the BPF and MDFBP algorithms can reconstruct the image on the

  1. Exudate detection in color retinal images for mass screening of diabetic retinopathy.

    Science.gov (United States)

    Zhang, Xiwei; Thibault, Guillaume; Decencière, Etienne; Marcotegui, Beatriz; Laÿ, Bruno; Danno, Ronan; Cazuguel, Guy; Quellec, Gwénolé; Lamard, Mathieu; Massin, Pascale; Chabouis, Agnès; Victor, Zeynep; Erginay, Ali

    2014-10-01

    The automatic detection of exudates in color eye fundus images is an important task in applications such as diabetic retinopathy screening. The presented work has been undertaken in the framework of the TeleOphta project, whose main objective is to automatically detect normal exams in a tele-ophthalmology network, thus reducing the burden on the readers. A new clinical database, e-ophtha EX, containing precisely manually contoured exudates, is introduced. As opposed to previously available databases, e-ophtha EX is very heterogeneous. It contains images gathered within the OPHDIAT telemedicine network for diabetic retinopathy screening. Image definition, quality, as well as patients condition or the retinograph used for the acquisition, for example, are subject to important changes between different examinations. The proposed exudate detection method has been designed for this complex situation. We propose new preprocessing methods, which perform not only normalization and denoising tasks, but also detect reflections and artifacts in the image. A new candidates segmentation method, based on mathematical morphology, is proposed. These candidates are characterized using classical features, but also novel contextual features. Finally, a random forest algorithm is used to detect the exudates among the candidates. The method has been validated on the e-ophtha EX database, obtaining an AUC of 0.95. It has been also validated on other databases, obtaining an AUC between 0.93 and 0.95, outperforming state-of-the-art methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  3. Spectroscopic imaging studies of nanoscale polarity and mass transport phenomena in self-assembled organic nanotubes.

    Science.gov (United States)

    Xu, Hao; Nagasaka, Shinobu; Kameta, Naohiro; Masuda, Mitsutoshi; Ito, Takashi; Higgins, Daniel A

    2017-08-02

    Synthetic organic nanotubes self-assembled from bolaamphiphile surfactants are now being explored for use as drug delivery vehicles. In this work, several factors important to their implementation in drug delivery are explored. All experiments are performed with the nanotubes immersed in ethanol. First, Nile Red (NR) and a hydroxylated Nile Red derivative (NR-OH) are loaded into the nanotubes and spectroscopic fluorescence imaging methods are used to determine the apparent dielectric constant of their local environment. Both are found in relatively nonpolar environments, with the NR-OH molecules preferring regions of relatively higher dielectric constant compared to NR. Unique two-color imaging fluorescence correlation spectroscopy (imaging FCS) measurements are then used along with the spectroscopic imaging results to deduce the dielectric properties of the environments sensed by mobile and immobile populations of probe molecules. The results reveal that mobile NR molecules pass through less polar regions, likely within the nanotube walls, while immobile NR molecules are found in more polar regions, possibly near the nanotube surfaces. In contrast, mobile and immobile NR-OH molecules are found to locate in environments of similar polarity. The imaging FCS results also provide quantitative data on the apparent diffusion coefficient for each dye. The mean diffusion coefficient for the NR dye was approximately two-fold larger than that of NR-OH. Slower diffusion by the latter could result from its additional hydrogen bonding interactions with polar triglycine, amine, and glucose moieties near the nanotube surfaces. The knowledge gained in these studies will allow for the development of nanotubes that are better engineered for applications in the controlled transport and release of uncharged, dipolar drug molecules.

  4. Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging for Peptide and Protein Analyses: A Critical Review of On-Tissue Digestion

    NARCIS (Netherlands)

    Cillero-Pastor, B.; Heeren, R.M.A.

    2013-01-01

    Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) has established itself among the plethora of mass spectrometry applications. In the biomedical field, MALDI-MSI is being more frequently recognized as a new method for the discovery of biomarkers and targets of

  5. Islet-selectivity of G-protein coupled receptor ligands evaluated for PET imaging of pancreatic {beta}-cell mass

    Energy Technology Data Exchange (ETDEWEB)

    Cline, Gary W., E-mail: gary.cline@yale.edu [Yale University School of Medicine (United States); Zhao, Xiaojian [Yale University School of Medicine (United States); Jakowski, Amy B.; Soeller, Walter C.; Treadway, Judith L. [Pfizer Global Research and Development, Pfizer Inc., Groton CT (United States)

    2011-09-02

    Highlights: {yields} We screened G-protein coupled receptors for imaging pancreatic. {yields} Database mining and immunohistochemistry identified GPCRs enriched in {beta}-cells. {yields} In vitro and in vivo assays were used to determine exocrine vs endocrine specificity. {yields} GPCR candidates for imaging of {beta}-cell mass are Prokineticin-1R, mGluR5, and GLP-1R. -- Abstract: A critical unmet need exists for methods to quantitatively measure endogenous pancreatic {beta}-cell mass (BCM) for the clinical evaluation of therapies to prevent or reverse loss of BCM and diabetes progression. Our objective was to identify G-protein coupled receptors (GPCRs) that are expressed with a high degree of specificity to islet {beta}-cells for receptor-targeted imaging of BCM. GPCRs enriched in pancreatic islets relative to pancreas acinar and hepatic tissue were identified using a database screen. Islet-specific expression was confirmed by human pancreas immunohistochemistry (IHC). In vitro selectivity assessment was determined from the binding and uptake of radiolabeled ligands to the rat insulinoma INS-1 832/13 cell line and isolated rat islets relative to the exocrine pancreas cell-type, PANC-1. Tail-vein injections of radioligands into rats were used to determine favorable image criteria of in vivo biodistribution to the pancreas relative to other internal organs (i.e., liver, spleen, stomach, and lungs). Database and IHC screening identified four candidate receptors for further in vitro and in vivo evaluation for PET imaging of BCM: prokineticin-1 receptor (PK-1R), metabotropic glutamate receptor type-5 (mGluR5), neuropeptide Y-2 receptor (NPY-2R), and glucagon-like peptide 1 receptor (GLP-1R). In vitro specificity ratios gave the following receptor rank order: PK-1R > GLP-1R > NPY-2R > mGluR5. The biodistribution rank order of selectivity to the pancreas was found to be PK-1R > VMAT2 {approx} GLP-1R > mGluR5. Favorable islet selectivity and biodistribution

  6. Islet-selectivity of G-protein coupled receptor ligands evaluated for PET imaging of pancreatic β-cell mass

    International Nuclear Information System (INIS)

    Cline, Gary W.; Zhao, Xiaojian; Jakowski, Amy B.; Soeller, Walter C.; Treadway, Judith L.

    2011-01-01

    Highlights: → We screened G-protein coupled receptors for imaging pancreatic. → Database mining and immunohistochemistry identified GPCRs enriched in β-cells. → In vitro and in vivo assays were used to determine exocrine vs endocrine specificity. → GPCR candidates for imaging of β-cell mass are Prokineticin-1R, mGluR5, and GLP-1R. -- Abstract: A critical unmet need exists for methods to quantitatively measure endogenous pancreatic β-cell mass (BCM) for the clinical evaluation of therapies to prevent or reverse loss of BCM and diabetes progression. Our objective was to identify G-protein coupled receptors (GPCRs) that are expressed with a high degree of specificity to islet β-cells for receptor-targeted imaging of BCM. GPCRs enriched in pancreatic islets relative to pancreas acinar and hepatic tissue were identified using a database screen. Islet-specific expression was confirmed by human pancreas immunohistochemistry (IHC). In vitro selectivity assessment was determined from the binding and uptake of radiolabeled ligands to the rat insulinoma INS-1 832/13 cell line and isolated rat islets relative to the exocrine pancreas cell-type, PANC-1. Tail-vein injections of radioligands into rats were used to determine favorable image criteria of in vivo biodistribution to the pancreas relative to other internal organs (i.e., liver, spleen, stomach, and lungs). Database and IHC screening identified four candidate receptors for further in vitro and in vivo evaluation for PET imaging of BCM: prokineticin-1 receptor (PK-1R), metabotropic glutamate receptor type-5 (mGluR5), neuropeptide Y-2 receptor (NPY-2R), and glucagon-like peptide 1 receptor (GLP-1R). In vitro specificity ratios gave the following receptor rank order: PK-1R > GLP-1R > NPY-2R > mGluR5. The biodistribution rank order of selectivity to the pancreas was found to be PK-1R > VMAT2 ∼ GLP-1R > mGluR5. Favorable islet selectivity and biodistribution characteristics suggest several GPCRs as potential

  7. Three-Dimensional Imaging of Lipids and Metabolites in Tissues by Nanospray Desorption Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lanekoff, Ingela T.; Burnum-Johnson, Kristin E.; Thomas, Mathew; Cha, Jeeyeon; Dey, Sudhansu K.; yang, Pengxiang; Prieto, Mari; Laskin, Julia

    2015-03-01

    Abstract Three-dimensional (3D) imaging of tissue sections is a new frontier in mass spectrometry imaging (MSI). Here we report on fast 3D imaging of lipids and metabolites associated with mouse uterine decidual cells and embryo at the implantation site on day 6 of pregnancy. 2D imaging of 16-20 serial tissue sections deposited on the same glass slide was performed using nanospray desorption electrospray ionization (nano-DESI) – an ambient ionization technique that enables sensitive localized analysis of analytes on surfaces without special sample pre-treatment. In this proof-of-principle study, nano-DESI was coupled to a high-resolution Q-Exactive instrument operated at high repetition rate of >5 Hz with moderate mass resolution of 35,000 (m/Δm at m/z 200), which enabled acquisition of the entire 3D image with a spatial resolution of ~150 μm in less than 4.5 hours. The results demonstrate localization of acetylcholine in the primary decidual zone (PDZ) of the implantation site throughout the depth of the tissue examined, indicating an important role of this signaling molecule in decidualization. Choline and phosphocholine – metabolites associated with cell growth – are enhanced in the PDZ and abundant in other cellular regions of the implantation site. Very different 3D distributions were obtained for fatty acids (FA), oleic acid and linoleic acid (FA 18:1 and FA 18:2), differing only by one double bond. Localization of FA 18:2 in the PDZ indicates its important role in decidualization while FA 18:1 is distributed more evenly throughout the tissue. In contrast, several lysophosphatidylcholines (LPC) observed in this study show donut-like distributions with localization around the PDZ. Complementary distributions with minimal overlap were observed for LPC 18:0 and FA 18:2 while the 3D image of the potential precursor phosphatidylcholine (PC 36:2) showed a significant overlap with both LPC 18:0 and FA 18:2.

  8. MALDI Mass Spectral Imaging of Bile Acids Observed as Deprotonated Molecules and Proton-Bound Dimers from Mouse Liver Sections

    Science.gov (United States)

    Rzagalinski, Ignacy; Hainz, Nadine; Meier, Carola; Tschernig, Thomas; Volmer, Dietrich A.

    2018-02-01

    Bile acids (BAs) play two vital roles in living organisms, as they are involved in (1) the secretion of cholesterol from liver, and (2) the lipid digestion/absorption in the intestine. Abnormal bile acid synthesis or secretion can lead to severe liver disorders. Even though there is extensive literature on the mass spectrometric determination of BAs in biofluids and tissue homogenates, there are no reports on the spatial distribution in the biliary network of the liver. Here, we demonstrate the application of high mass resolution/mass accuracy matrix-assisted laser desorption/ionization (MALDI)-Fourier-transform ion cyclotron resonance (FTICR) to MS imaging (MSI) of BAs at high spatial resolutions (pixel size, 25 μm). The results show chemical heterogeneity of the mouse liver sections with a number of branching biliary and blood ducts. In addition to ion signals from deprotonation of the BA molecules, MALDI-MSI generated several further intense signals at larger m/z for the BAs. These signals were spatially co-localized with the deprotonated molecules and easily misinterpreted as additional products of BA biotransformations. In-depth analysis of accurate mass shifts and additional electrospray ionization and MALDI-FTICR experiments, however, confirmed them as proton-bound dimers. Interestingly, dimers of bile acids, but also unusual mixed dimers of different taurine-conjugated bile acids and free taurine, were identified. Since formation of these complexes will negatively influence signal intensities of the desired [M - H]- ions and significantly complicate mass spectral interpretations, two simple broadband techniques were proposed for non-selective dissociation of dimers that lead to increased signals for the deprotonated BAs. [Figure not available: see fulltext.

  9. Bilateral renal masses in a 10-year-old girl with renal failure and urinary tract infection: the importance of functional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Urbania, Thomas H. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, 505 Parnassus Ave., Box 0628, San Francisco, CA (United States); Kammen, Bamidele F.; Nancarrow, Paul A. [Children' s Hospital and Research Center Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Morrell, Rose Ellen [Children' s Hospital and Research Center Oakland, Department of Nephrology, Oakland, CA (United States)

    2009-02-15

    Renal sonography is a routine step in the evaluation of new onset renal failure. When renal masses are discovered in this setting, functional imaging may be critical. We report a case of bilateral renal masses in a girl with urinary tract infection and renal insufficiency found to have vesicoureteral reflux. Renal scintigraphy revealed these masses to be the only remaining functional renal tissue, preventing potentially harmful resection. (orig.)

  10. Bilateral renal masses in a 10-year-old girl with renal failure and urinary tract infection: the importance of functional imaging

    International Nuclear Information System (INIS)

    Urbania, Thomas H.; Kammen, Bamidele F.; Nancarrow, Paul A.; Morrell, Rose Ellen

    2009-01-01

    Renal sonography is a routine step in the evaluation of new onset renal failure. When renal masses are discovered in this setting, functional imaging may be critical. We report a case of bilateral renal masses in a girl with urinary tract infection and renal insufficiency found to have vesicoureteral reflux. Renal scintigraphy revealed these masses to be the only remaining functional renal tissue, preventing potentially harmful resection. (orig.)

  11. Molecular imaging of banknote and questioned document using solvent-free gold nanoparticle-assisted laser desorption/ionization imaging mass spectrometry.

    Science.gov (United States)

    Tang, Ho-Wai; Wong, Melody Yee-Man; Chan, Sharon Lai-Fung; Che, Chi-Ming; Ng, Kwan-Ming

    2011-01-01

    Direct chemical analysis and molecular imaging of questioned documents in a non/minimal-destructive manner is important in forensic science. Here, we demonstrate that solvent-free gold-nanoparticle-assisted laser desorption/ionization mass spectrometry is a sensitive and minimal destructive method for direct detection and imaging of ink and visible and/or fluorescent dyes printed on banknotes or written on questioned documents. Argon ion sputtering of a gold foil allows homogeneous coating of a thin layer of gold nanoparticles on banknotes and checks in a dry state without delocalizing spatial distributions of the analytes. Upon N(2) laser irradiation of the gold nanoparticle-coated banknotes or checks, abundant ions are desorbed and detected. Recording the spatial distributions of the ions can reveal the molecular images of visible and fluorescent ink printed on banknotes and determine the printing order of different ink which may be useful in differentiating real banknotes from fakes. The method can also be applied to identify forged parts in questioned documents, such as number/writing alteration on a check, by tracing different writing patterns that come from different pens.

  12. Atmospheric pressure imaging mass spectrometry of drugs with various ablating lasers

    International Nuclear Information System (INIS)

    Moshkunov, K A; Alimpiev, S S; Pento, A V; Grechnikov, A A; Nikifirov, S M; Simanovsky, Ya O

    2014-01-01

    The atmospheric pressure mass spectrometric detection efficiency of organic species (tofisopam and verapamil) was measured by means of the laser ablation of dried solution drops containing known amount of the analyte. Ablated molecules were ionized by an atmospheric pressure laser plasma cell and then introduced in the TOF mass-spectrometer. The spot was formed by dripping 2 μl of solution on the stainless steel substrate and consequent drying. Then it was scanned by an intense ablating beam of various lasers (CO 2 , Nd:YAG and femtosecond fiber laser) until the spot was completely eroded during the non-stop MS-analysis of ablated material. The sensitivity was defined as the ratio of the total ion current integral of the relevant mass peaks to the amount of molecules in the spot. All the tested lasers are suitable for the ablation and subsequent MS-detection of organic species in dried solution spots given enough power deposition is provided. The measured sensitivity values reach 0.1 ions/fg of tested analytes

  13. In situ monitoring of molecular changes during cell differentiation processes in marine macroalgae through mass spectrometric imaging.

    Science.gov (United States)

    Kessler, Ralf W; Crecelius, Anna C; Schubert, Ulrich S; Wichard, Thomas

    2017-08-01

    Matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) was employed to discriminate between cell differentiation processes in macroalgae. One of the key developmental processes in the algal life cycle is the production of germ cells (gametes and zoids). The gametogenesis of the marine green macroalga Ulva mutabilis (Chlorophyta) was monitored by metabolomic snapshots of the surface, when blade cells differentiate synchronously into gametangia and giving rise to gametes. To establish MSI for macroalgae, dimethylsulfoniopropionate (DMSP), a known algal osmolyte, was determined. MSI of the surface of U. mutabilis followed by chemometric data analysis revealed dynamic metabolomic changes during cell differentiation. DMSP and a total of 55 specific molecular biomarkers, which could be assigned to important stages of the gametogenesis, were detected. Our research contributes to the understanding of molecular mechanisms underlying macroalgal cell differentiation. Graphical abstract Molecular changes during cell differentiation of the marine macroalga Ulva were visualized by matrix assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI).

  14. The Role of Apparent Diffusion Coefficient Quantification in Differentiating Benign and Malignant Renal Masses by 3 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Göya, Cemil; Hamidi, Cihad; Bozkurt, Yaşar; Yavuz, Alpaslan; Kuday, Suzan; Gümüş, Hatice; Türkçü, Gül; Hattapoğlu, Salih; Bilici, Aslan

    2015-07-01

    Diffusion-weighted magnetic resonance imaging (DWI) is a widely-accepted diagnostic modality whose efficacy has been investigated by numerous past studies in the differentiation of malignant lesions from benign entities. The aim of this study was to evaluate the efficiency of diffusion-weighted magnetic resonance imaging in the characterization of renal lesions. Diagnostic accuracy study. A total of 137 patients with renal lesions were included in this study. The median apparent diffusion coefficient (ADC) values as well as the b 800 and b 1600 signal intensities of normal kidneys, solid components of mixed renal masses, and total cystic lesions were evaluated. There were significant differences between the ADC values of lesions and normal renal parenchyma, and between the ADC values of benign and malignant renal lesions on DWIs at b values of 800 and 1600 s/mm(2) (pbenign and malignant renal lesions. A cutoff value of 1.623 × 10(-3) mm(2)/s for the ADC with a b value of 1600 s/mm(2) provided 79% sensitivity and 96% specificity (pbenign and malignant renal lesions. Accurate assessment of renal masses is important for determining the necessity for surgical intervention. DWI provides additional value by differentiating benign from malignant renal tumors and can be added to routine kidney MRI protocols.

  15. A RECENT ACCRETION BURST IN THE LOW-MASS PROTOSTAR IRAS 15398-3359: ALMA IMAGING OF ITS RELATED CHEMISTRY

    International Nuclear Information System (INIS)

    Jørgensen, Jes K.; Brinch, Christian; Lindberg, Johan E.; Bisschop, Suzanne E.; Visser, Ruud; Bergin, Edwin A.; Sakai, Nami; Yamamoto, Satoshi; Harsono, Daniel; Van Dishoeck, Ewine F.; Persson, Magnus V.

    2013-01-01

    Low-mass protostars have been suggested to show highly variable accretion rates throughout their evolution. Such changes in accretion, and related heating of their ambient envelopes, may trigger significant chemical variations on different spatial scales and from source-to-source. We present images of emission from C 17 O, H 13 CO + , CH 3 OH, C 34 S and C 2 H toward the low-mass protostar IRAS 15398-3359 on 0.''5 (75 AU diameter) scales with the Atacama Large Millimeter/submillimeter Array at 340 GHz. The resolved images show that the emission from H 13 CO + is only present in a ring-like structure with a radius of about 1-1.''5 (150-200 AU) whereas the CO and other high dipole moment molecules are centrally condensed toward the location of the central protostar. We propose that HCO + is destroyed by water vapor present on small scales. The origin of this water vapor is likely an accretion burst during the last 100-1000 yr increasing the luminosity of IRAS 15398-3359 by a factor of 100 above its current luminosity. Such a burst in luminosity can also explain the centrally condensed CH 3 OH and extended warm carbon-chain chemistry observed in this source and furthermore be reflected in the relative faintness of its compact continuum emission compared to other protostars

  16. In Situ Analysis of Bacterial Lipopeptide Antibiotics by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging.

    Science.gov (United States)

    Debois, Delphine; Ongena, Marc; Cawoy, Hélène; De Pauw, Edwin

    2016-01-01

    Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) is a technique developed in the late 1990s enabling the two-dimensional mapping of a broad variety of biomolecules present at the surface of a sample. In many applications including pharmaceutical studies or biomarker discovery, the distribution of proteins, lipids or drugs, and metabolites may be visualized within tissue sections. More recently, MALDI MSI has become increasingly applied in microbiology where the versatility of the technique is perfectly suited to monitor the metabolic dynamics of bacterial colonies. The work described here is focused on the application of MALDI MSI to map secondary metabolites produced by Bacilli, especially lipopeptides, produced by bacterial cells during their interaction with their environment (bacteria, fungi, plant roots, etc.). This chapter addresses the advantages and challenges that the implementation of MALDI MSI to microbiological samples entails, including detailed protocols on sample preparation (from both microbiologist and mass spectrometrist points of view), matrix deposition, and data acquisition and interpretation. Lipopeptide images recorded from confrontation plates are also presented.

  17. EVENT DETECTION USING MOBILE PHONE MASS GPS DATA AND THEIR RELIAVILITY VERIFICATION BY DMSP/OLS NIGHT LIGHT IMAGE

    Directory of Open Access Journals (Sweden)

    A. Yuki

    2016-06-01

    Full Text Available In this study, we developed a method to detect sudden population concentration on a certain day and area, that is, an “Event,” all over Japan in 2012 using mass GPS data provided from mobile phone users. First, stay locations of all phone users were detected using existing methods. Second, areas and days where Events occurred were detected by aggregation of mass stay locations into 1-km-square grid polygons. Finally, the proposed method could detect Events with an especially large number of visitors in the year by removing the influences of Events that occurred continuously throughout the year. In addition, we demonstrated reasonable reliability of the proposed Event detection method by comparing the results of Event detection with light intensities obtained from the night light images from the DMSP/OLS night light images. Our method can detect not only positive events such as festivals but also negative events such as natural disasters and road accidents. These results are expected to support policy development of urban planning, disaster prevention, and transportation management.

  18. Incongruence in body image and body mass index: A surrogate risk marker in Black women for type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Rynal Devanathan

    2013-07-01

    Full Text Available Background: Excess weight contributes to the development and progression of Type 2 diabetes mellitus (T2DM. Distorted body image amongst urban Black women and the perception that thinness is linked with HIV, may however be compounding the problem, particularly in areas with a high HIV burden. Objectives: This study aimed to compare the perception of body image in urban Black women with and without T2DM. Methods: A cross-sectional comparative study was conducted on 328 Black women systematically sampled into two groups (with and without T2DM. Body mass index (BMI (weight [kg]/height[m2] was determined and the adapted Stunkard Body Image Silhouettes for Black women was used to determine perceived body image (PBI. Results: Seventy-two per cent had T2DM and in this group 89% were obese, with a mean BMI of 39.5 kg/m2 (s.d. ± 8.5. In the non-diabetes group (NDG 44% were obese, with a mean BMIof 31.3 kg/m2 (s.d. ± 9.0 Black women underestimated their body image across all weight categories (p < 0.05. Both groups (99% of the study group also perceived thinness as being associated with HIV. Conclusions: This study identified an incongruence between PBI and actual BMI amongst urban Black women. This, combined with their belief that thinness is associated with HIV, places those with T2DM at risk of secondary complications arising from diabetes mellitus, and those without diabetes mellitus at a higher risk of developing T2DM. A discrepancy between PBI and BMI may therefore serve as a risk marker to alert clinicians to use a more ethno-cultural specific approach in engaging with urban Black women regarding weight loss strategies in the future.

  19. Soft tissue masses with myxoid stroma: Can conventional magnetic resonance imaging differentiate benign from malignant tumors?

    Energy Technology Data Exchange (ETDEWEB)

    Crombe, A., E-mail: amandine.crombe@ens-lyon.fr [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Alberti, N. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Stoeckle, E. [Department of Surgery, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Brouste, V. [Clinical and Epidemiological Research Unit, Institut Bergonié, 33000 Bordeaux (France); Buy, X. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Coindre, J-M. [Department of Pathology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Kind, M. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France)

    2016-10-15

    Objectives: To retrospectively evaluate the diagnostic performance of morphological signs observed on conventional magnetic resonance (MR) imaging to differentiate benign from malignant peripheral solid tumors of soft tissue with myxoid stroma. Methods: MR images from 95 consecutive histopathologically proven tumors (26 benign and 69 malignant) of soft tissues with myxoid components were evaluated in our tertiary referral center. Two radiologists, blind to pathology results, independently reviewed conventional MR sequences including at least a) one T2-weighted sequence with or without fat suppression; b) one T1-weighted sequence without fat suppression; and c) one T1-weighted sequence with gadolinium-complex contrast enhancement and fat suppression. Multiple criteria were defined to analyze morphology, margins, architecture and tumor periphery and evaluated for each lesion. Intra- and inter-observer reproducibility and Odds ratios were calculated for each criterion. Results: The most relevant and reproducible criteria to significantly predict malignancy were: (1) ill-defined tumor margins, (2) a hemorrhagic component, (3) intra-tumoral fat, (4) fibrosis and (5) the “tail sign”. A lesion is classified as malignant if any of these 5 criteria is present, and benign if none of them are observed. Therefore, this combination provides a sensitivity of 92.9% and a specificity of 93.3%. Conclusion: Conventional MR imaging provides reproducible criteria that can be combined to differentiate between benign and malignant solid tumors of soft tissue with myxoid stroma.

  20. Imprint Desorption Electrospray Ionization Mass Spectrometry Imaging for Monitoring Secondary Metabolites Production during Antagonistic Interaction of Fungi.

    Science.gov (United States)

    Tata, Alessandra; Perez, Consuelo; Campos, Michel L; Bayfield, Mark A; Eberlin, Marcos N; Ifa, Demian R

    2015-12-15

    Direct analysis of microbial cocultures grown on agar media by desorption electrospray ionization mass spectrometry (DESI-MS) is quite challenging. Due to the high gas pressure upon impact with the surface, the desorption mechanism does not allow direct imaging of soft or irregular surfaces. The divots in the agar, created by the high-pressure gas and spray, dramatically change the geometry of the system decreasing the intensity of the signal. In order to overcome this limitation, an imprinting step, in which the chemicals are initially transferred to flat hard surfaces, was coupled to DESI-MS and applied for the first time to fungal cocultures. Note that fungal cocultures are often disadvantageous in direct imaging mass spectrometry. Agar plates of fungi present a complex topography due to the simultaneous presence of dynamic mycelia and spores. One of the most devastating diseases of cocoa trees is caused by fungal phytopathogen Moniliophthora roreri. Strategies for pest management include the application of endophytic fungi, such as Trichoderma harzianum, that act as biocontrol agents by antagonizing M. roreri. However, the complex chemical communication underlying the basis for this phytopathogen-dependent biocontrol is still unknown. In this study, we investigated the metabolic exchange that takes place during the antagonistic interaction between M. roreri and T. harzianum. Using imprint-DESI-MS imaging we annotated the secondary metabolites released when T. harzianum and M. roreri were cultured in isolation and compared these to those produced after 3 weeks of coculture. We identified and localized four phytopathogen-dependent secondary metabolites, including T39 butenolide, harzianolide, and sorbicillinol. In order to verify the reliability of the imprint-DESI-MS imaging data and evaluate the capability of tape imprints to extract fungal metabolites while maintaining their localization, six representative plugs along the entire M. roreri/T. harzianum

  1. Research on perfusion weighted imaging and diffusion weighted imaging of pancreatic masses at 3.0 T MR

    International Nuclear Information System (INIS)

    Yao Xiuzhong; Zeng mengsu; Rao Shengxiang; Ji Yuan

    2011-01-01

    Objective: To investigate the value of MR perfusion parameters and ADC in the diagnosis of pancreatic cancer and pancreatic mass at 3.0 T MR. Methods: Twenty healthy volunteers and 25 patients with pancreatic cancers proven by pathological results underwent MR PWI at a 3.0 T scanner. A two-compartment model was used to quantify K trans , K ep and V e in the pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue. All parameters among different tissues were analyzed and compared with ANONA. Fifteen normal volunteers and 58 patients, including 30 patients with pancreatic cancer (proven histopathologically), 9 patients with pancreatitis pseudotumor (4 patients proven by histopathological results, 5 patients proven by follow-up after treatment), 9 patients with solid pseudopapillary tumor of pancreas (SPTP, proven histopathologically) and 10 patients with pancreatic neuroendocrine tumor (PET, proven by histopathology), underwent respiratory-triggered DWI on 3.0 T. ADC values of normal pancreas and all types of pancreatic lesions were statistically analyzed and compared with ANONA. ROC curve was used to analyze the diagnostic power of ADC value. Results: K trans of pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were (1.66±1.25), (3.77±2.67), (1.16±0.94) and (2.69±1.46 )/min respectively (F= 8. 160, P ep of pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were (2. 53 +1. 55) , (5.64±2.64), (1.70±0.91) and (4.28±1.64)/min respectively (F=4.544, P ep in pancreatic cancer was statistically lower than that in normal pancreatic tissue (P= 0.035) and adjacent pancreatic tissue (P=0.041). The median of V e among the pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were 0.926, 0.839, 0.798 and 0.659 respectively (χ 2 =12

  2. The combined use of US and MR imaging for the diagnosis of masses in the parotid region

    International Nuclear Information System (INIS)

    Goto, T.K.; Yoshiura, K.; Nakayama, E.; Yuasa, K.; Tabata, O.; Nakano, T.; Kawazu, T.; Tanaka, T.; Miwa, K.; Shimizu, M.; Chikui, T.; Okamura, K.; Kanda, S.

    2000-01-01

    To evaluate the usefulness of the combination of the two non-invasive modalities US and MR imaging to diagnose masses in the parotid region. The US and MR findings of 21 patients with parotid masses were analyzed retrospectively by two radiologists without any clinical or histopathological information. The specific points evaluated were location, shape, margin, internal architecture, and intensity level on both US and MR, posterior echo enhancement on US, and capsule-like lining of the tumor on MR. The findings concerning the shape and margin on US and MR were in fairly good agreement. Concerning the findings of the internal architecture, US could reveal the minute structures of the tumor while MR demonstrated differences in the signal intensities of histological tissue types of the various tumors. The posterior echo enhancement on US and the capsule-like lining on MR of the tumors were also useful for the diagnosis. Our results suggest that the combination of US and MR is useful for examining soft tissue masses in the parotid region to make a more accurate diagnosis, and not just differentiate malignant lesions from those which are benign

  3. Lean body mass correction of standardized uptake value in simultaneous whole-body positron emission tomography and magnetic resonance imaging

    Science.gov (United States)

    Jochimsen, Thies H.; Schulz, Jessica; Busse, Harald; Werner, Peter; Schaudinn, Alexander; Zeisig, Vilia; Kurch, Lars; Seese, Anita; Barthel, Henryk; Sattler, Bernhard; Sabri, Osama

    2015-06-01

    This study explores the possibility of using simultaneous positron emission tomography—magnetic resonance imaging (PET-MRI) to estimate the lean body mass (LBM) in order to obtain a standardized uptake value (SUV) which is less dependent on the patients' adiposity. This approach is compared to (1) the commonly-used method based on a predictive equation for LBM, and (2) to using an LBM derived from PET-CT data. It is hypothesized that an MRI-based correction of SUV provides a robust method due to the high soft-tissue contrast of MRI. A straightforward approach to calculate an MRI-derived LBM is presented. It is based on the fat and water images computed from the two-point Dixon MRI primarily used for attenuation correction in PET-MRI. From these images, a water fraction was obtained for each voxel. Averaging over the whole body yielded the weight-normalized LBM. Performance of the new approach in terms of reducing variations of 18F-Fludeoxyglucose SUVs in brain and liver across 19 subjects was compared with results using predictive methods and PET-CT data to estimate the LBM. The MRI-based method reduced the coefficient of variation of SUVs in the brain by 41  ± 10% which is comparable to the reduction by the PET-CT method (35  ± 10%). The reduction of the predictive LBM method was 29  ± 8%. In the liver, the reduction was less clear, presumably due to other sources of variation. In conclusion, employing the Dixon data in simultaneous PET-MRI for calculation of lean body mass provides a brain SUV which is less dependent on patient adiposity. The reduced dependency is comparable to that obtained by CT and predictive equations. Therefore, it is more comparable across patients. The technique does not impose an overhead in measurement time and is straightforward to implement.

  4. Early Detection of Biofouling on Water Purification Membranes by Ambient Ionization Mass Spectrometry Imaging.

    Science.gov (United States)

    Jakka Ravindran, Swathy; Kumar, Ramesh; Srimany, Amitava; Philip, Ligy; Pradeep, Thalappil

    2018-01-02

    By direct analysis of water purification membranes using ambient ionization mass spectrometry, an attempt has been made to understand the molecular signatures of bacterial fouling. Membrane based purification methods are used extensively in water treatment, and a major challenge for them is biofouling. The buildup of microbes and their extracellular polymeric matrix clog the purification membranes and reduce their efficiency. To understand the early stages of bacterial fouling on water purification membranes, we have used desorption electrospray ionization mass spectrometry (DESI MS), where ion formation occurs in ambient conditions and the ionization event is surface sensitive. Biosurfactants at the air-water interface generated by microorganisms as a result of quorum sensing, influence the water-membrane interface and are important for the bacterial attachment. We show that these biosurfactants produced by bacteria can be indicator molecular species signifying initiation of biofilms on membrane surfaces, demonstrated by specific DESI MS signatures. In Pseudomonas aeruginosa, one of the best studied models for biofilm formation, this process is mediated by rhamnolipids forewarning bacterial fouling. Species dependent variation of such molecules can be used for the precise identification of the microorganisms, as revealed by studies on P. aeroginosa (ATCC 25619). The production of biosurfactants is tightly regulated at the transcriptional level by the quorum-sensing (QS) response. Thus, secretion of these extracellular molecules across the membrane surface allows rapid screening of the biofilm community. We show that, the ambient ionization mass spectrometry can detect certain toxic heavy metals present in water, using surfactant-metal complexes as analytes. We believe that such studies conducted on membranes in various input water streams will help design suitable membrane processes specific to the input streams.

  5. Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera.

    Science.gov (United States)

    Amini, Kasra; Boll, Rebecca; Lauer, Alexandra; Burt, Michael; Lee, Jason W L; Christensen, Lauge; Brauβe, Felix; Mullins, Terence; Savelyev, Evgeny; Ablikim, Utuq; Berrah, Nora; Bomme, Cédric; Düsterer, Stefan; Erk, Benjamin; Höppner, Hauke; Johnsson, Per; Kierspel, Thomas; Krecinic, Faruk; Küpper, Jochen; Müller, Maria; Müller, Erland; Redlin, Harald; Rouzée, Arnaud; Schirmel, Nora; Thøgersen, Jan; Techert, Simone; Toleikis, Sven; Treusch, Rolf; Trippel, Sebastian; Ulmer, Anatoli; Wiese, Joss; Vallance, Claire; Rudenko, Artem; Stapelfeldt, Henrik; Brouard, Mark; Rolles, Daniel

    2017-07-07

    Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C 6 H 3 F 2 I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. We show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths.

  6. Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2017-09-25

    Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm 3 ) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; Pcine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (Pcine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.

  7. Simultaneous imaging of multiple neurotransmitters and neuroactive substances in the brain by desorption electrospray ionization mass spectrometry.

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Strittmatter, Nicole; Nilsson, Anna; Källback, Patrik; Alvarsson, Alexandra; Zhang, Xiaoqun; Vallianatou, Theodosia; Svenningsson, Per; Goodwin, Richard J A; Andren, Per E

    2016-08-01

    With neurological processes involving multiple neurotransmitters and neuromodulators, it is important to have the ability to directly map and quantify multiple signaling molecules simultaneously in a single analysis. By utilizing a molecular-specific approach, namely desorption electrospray ionization mass spectrometry imaging (DESI-MSI), we demonstrated that the technique can be used to image multiple neurotransmitters and their metabolites (dopamine, dihydroxyphenylacetic acid, 3-methoxytyramine, serotonin, glutamate, glutamine, aspartate, γ-aminobutyric acid, adenosine) as well as neuroactive drugs (amphetamine, sibutramine, fluvoxamine) and drug metabolites in situ directly in brain tissue sections. The use of both positive and negative ionization modes increased the number of identified molecular targets. Chemical derivatization by charge-tagging the primary amines of molecules significantly increased the sensitivity, enabling the detection of low abundant neurotransmitters and other neuroactive substances previously undetectable by MSI. The sensitivity of the imaging approach of neurochemicals has a great potential in many diverse applications in fields such as neuroscience, pharmacology, drug discovery, neurochemistry, and medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. High-resolution magnetic resonance imaging tracks changes in organ and tissue mass in obese and aging rats.

    Science.gov (United States)

    Tang, Haiying; Vasselli, Joseph R; Wu, Ed X; Boozer, Carol N; Gallagher, Dympna

    2002-03-01

    Magnetic resonance imaging (MRI) has the ability to discriminate between various soft tissues in vivo. Whole body, specific organ, total adipose tissue (TAT), intra-abdominal adipose tissue (IAAT), and skeletal muscle (SM) weights determined by MRI were compared with weights determined by dissection and chemical analysis in two studies with male Sprague-Dawley rats. A 4.2-T MRI machine acquired high-resolution, in vivo, longitudinal whole body images of rats as they developed obesity or aged. Weights of the whole body and specific tissues were determined using computer image analysis software, including semiautomatic segmentation algorithms for volume calculations. High correlations were found for body weight (r = 0.98), TAT (r = 0.99), and IAAT (r = 0.98) between MRI and dissection and chemical analyses. MRI estimated the weight of the brain, kidneys, and spleen with high accuracy (r > 0.9), but overestimated IAAT, SM, and liver volumes. No differences were detected in organ weights using MRI and dissection measurements. Longitudinal MRI measurements made during the development of obesity and aging accurately represented changes in organ and tissue mass.

  9. Measuring Mass-Based Hygroscopicity of Atmospheric Particles through in situ Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Piens, Dominique` Y.; Kelly, Stephen T.; Harder, Tristan; Petters, Markus D.; O' Brien, Rachel; Wang, Bingbing; Teske, Ken; Dowell, Pat; Laskin, Alexander; Gilles, Mary K.

    2016-04-18

    Quantifying how atmospheric particles interact with water vapor is critical for understanding the effects of aerosols on climate. We present a novel method to measure the mass-based hygroscopicity of particles while characterizing their elemental and carbon functional group compositions. Since mass-based hygroscopicity is insensitive to particle geometry, it is advantageous for probing the hygroscopic behavior of atmospheric particles, which can have irregular morphologies. Combining scanning electron microscopy with energy dispersive X-ray analysis (SEM/EDX), scanning transmission X-ray microscopy (STXM) analysis, and in situ STXM humidification experiments, this method was validated using laboratory-generated, atmospherically relevant particles. Then, the hygroscopicity and elemental composition of 15 complex atmospheric particles were analyzed by leveraging quantification of C, N, and O from STXM, and complementary elemental quantification from SEM/EDX. We found three types of hygroscopic responses, and correlated high hygroscopicity with Na and Cl content. The mixing state determined for 158 particles broadly agreed with those of the humidified particles, indicating the potential to infer the atmospheric hygroscopic behavior from a selected subset of particles. These methods offer unique quantitative capabilities to characterize and correlate the hygroscopicity and chemistry of individual submicron atmospheric particles.

  10. Use of prediction equations to determine the accuracy of whole-body fat and fat-free mass and appendicular skeletal muscle mass measurements from a single abdominal image using computed tomography in advanced cancer patients.

    Science.gov (United States)

    Kilgour, Robert D; Cardiff, Katrina; Rosenthall, Leonard; Lucar, Enriqueta; Trutschnigg, Barbara; Vigano, Antonio

    2016-01-01

    Measurements of body composition using dual-energy X-ray absorptiometry (DXA) and single abdominal images from computed tomography (CT) in advanced cancer patients (ACP) have important diagnostic and prognostic value. The question arises as to whether CT scans can serve as surrogates for DXA in terms of whole-body fat-free mass (FFM), whole-body fat mass (FM), and appendicular skeletal muscle (ASM) mass. Predictive equations to estimate body composition for ACP from CT images have been proposed (Mourtzakis et al. 2008; Appl. Physiol. Nutr. Metabol. 33(5): 997-1006); however, these equations have yet to be validated in an independent cohort of ACP. Thus, this study evaluated the accuracy of these equations in estimating FFM, FM, and ASM mass using CT images at the level of the third lumbar vertebrae and compared these values with DXA measurements. FFM, FM, and ASM mass were estimated from the prediction equations proposed by Mourtzakis and colleagues (2008) using single abdominal CT images from 43 ACP and were compared with whole-body DXA scans using Spearman correlations and Bland-Altman analyses. Despite a moderate to high correlation between the actual (DXA) and predicted (CT) values for FM (rho = 0.93; p ≤ 0.001), FFM (rho = 0.78; p ≤ 0.001), and ASM mass (rho = 0.70; p ≤ 0.001), Bland-Altman analyses revealed large range-of-agreement differences between the 2 methods (29.39 kg for FFM, 15.47 kg for FM, and 3.99 kg for ASM mass). Based on the magnitude of these differences, we concluded that prediction equations using single abdominal CT images have poor accuracy, cannot be considered as surrogates for DXA, and may have limited clinical utility.

  11. SEARCHING FOR SCATTERERS: HIGH-CONTRAST IMAGING OF YOUNG STARS HOSTING WIDE-SEPARATION PLANETARY-MASS COMPANIONS

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Marta L.; Mawet, Dimitri [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, 1200 East California Boulevard, MC 249-17, Pasadena, CA 91125 (United States); Bowler, Brendan P.; Kraus, Adam L. [McDonald Observatory and Department of Astronomy, University of Texas at Austin, Austin, TX 78712 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Hinkley, Sasha [University of Exeter, Physics Department, Stocker Road, Exeter EX4 4QL (United Kingdom); Nielsen, Eric L.; Blunt, Sarah C. [SETI Institute, Carl Sagan Center, 189 Bernardo Avenue, Mountain View, CA 94043 (United States)

    2016-08-20

    We have conducted an angular differential imaging survey with NIRC2 at Keck in search of close-in substellar companions to a sample of seven systems with confirmed planetary-mass companions (PMCs) on wide orbits (>50 au). These wide-separation PMCs pose significant challenges to all three possible formation mechanisms: core accretion plus scattering, disk instability, and turbulent fragmentation. We explore the possibility that these companions formed closer in and were scattered out to their present-day locations by searching for other massive bodies at smaller separations. The typical sensitivity for this survey is Δ K ∼ 12.5 at 1″. We identify eight candidate companions, whose masses would reach as low as one Jupiter mass if gravitationally bound. From our multi-epoch astrometry we determine that seven of these are conclusively background objects, while the eighth near DH Tau is ambiguous and requires additional monitoring. We rule out the presence of >7 M {sub Jup} bodies in these systems down to 15–50 au that could be responsible for scattering. This result combined with the totality of evidence suggests that dynamical scattering is unlikely to have produced this population of PMCs. We detect orbital motion from the companions ROXs 42B b and ROXs 12 b, and from this determine 95% upper limits on the companions’ eccentricities of 0.58 and 0.83 respectively. Finally, we find that the 95% upper limit on the occurrence rate of additional planets with masses between 5 and 15 M {sub Jup} outside of 40 au in systems with PMCs is 54%.

  12. SEARCHING FOR SCATTERERS: HIGH-CONTRAST IMAGING OF YOUNG STARS HOSTING WIDE-SEPARATION PLANETARY-MASS COMPANIONS

    International Nuclear Information System (INIS)

    Bryan, Marta L.; Mawet, Dimitri; Bowler, Brendan P.; Kraus, Adam L.; Knutson, Heather A.; Hinkley, Sasha; Nielsen, Eric L.; Blunt, Sarah C.

    2016-01-01

    We have conducted an angular differential imaging survey with NIRC2 at Keck in search of close-in substellar companions to a sample of seven systems with confirmed planetary-mass companions (PMCs) on wide orbits (>50 au). These wide-separation PMCs pose significant challenges to all three possible formation mechanisms: core accretion plus scattering, disk instability, and turbulent fragmentation. We explore the possibility that these companions formed closer in and were scattered out to their present-day locations by searching for other massive bodies at smaller separations. The typical sensitivity for this survey is Δ K ∼ 12.5 at 1″. We identify eight candidate companions, whose masses would reach as low as one Jupiter mass if gravitationally bound. From our multi-epoch astrometry we determine that seven of these are conclusively background objects, while the eighth near DH Tau is ambiguous and requires additional monitoring. We rule out the presence of >7 M Jup bodies in these systems down to 15–50 au that could be responsible for scattering. This result combined with the totality of evidence suggests that dynamical scattering is unlikely to have produced this population of PMCs. We detect orbital motion from the companions ROXs 42B b and ROXs 12 b, and from this determine 95% upper limits on the companions’ eccentricities of 0.58 and 0.83 respectively. Finally, we find that the 95% upper limit on the occurrence rate of additional planets with masses between 5 and 15 M Jup outside of 40 au in systems with PMCs is 54%.

  13. Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses.

    Science.gov (United States)

    Wojcinski, Sebastian; Brandhorst, Kathrin; Sadigh, Gelareh; Hillemanns, Peter; Degenhardt, Friedrich

    2013-01-01

    Acoustic radiation force impulse imaging (ARFI) with Virtual Touch™ tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s) (P breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s"). Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s) (P < 0.001). The best diagnostic accuracy (75.9%) was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved.

  14. MALDI imaging mass spectrometry: discrimination of pathophysiological regions in traumatized skeletal muscle by characteristic peptide signatures.

    Science.gov (United States)

    Klein, Oliver; Strohschein, Kristin; Nebrich, Grit; Oetjen, Janina; Trede, Dennis; Thiele, Herbert; Alexandrov, Theodore; Giavalisco, Patrick; Duda, Georg N; von Roth, Philipp; Geissler, Sven; Klose, Joachim; Winkler, Tobias

    2014-10-01

    Due to formation of fibrosis and the loss of contractile muscle tissue, severe muscle injuries often result in insufficient healing marked by a significant reduction of muscle force and motor activity. Our previous studies demonstrated that the local transplantation of mesenchymal stromal cells into an injured skeletal muscle of the rat improves the functional outcome of the healing process. Since, due to the lack of sufficient markers, the accurate discrimination of pathophysiological regions in injured skeletal muscle is inadequate, underlying mechanisms of the beneficial effects of mesenchymal stromal cell transplantation on primary trauma and trauma adjacent muscle area remain elusive. For discrimination of these pathophysiological regions, formalin-fixed injured skeletal muscle tissue was analyzed by MALDI imaging MS. By using two computational evaluation strategies, a supervised approach (ClinProTools) and unsupervised segmentation (SCiLS Lab), characteristic m/z species could be assigned to primary trauma and trauma adjacent muscle regions. Using "bottom-up" MS for protein identification and validation of results by immunohistochemistry, we could identify two proteins, skeletal muscle alpha actin and carbonic anhydrase III, which discriminate between the secondary damage on adjacent tissue and the primary traumatized muscle area. Our results underscore the high potential of MALDI imaging MS to describe the spatial characteristics of pathophysiological changes in muscle. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. MR Imaging of papillary renal neoplasms: potential application for characterization of small renal masses

    International Nuclear Information System (INIS)

    Roy, Catherine; Sauer, Benoit; Lindner, Veronique; Lang, Herve; Saussine, Christian; Jacqmin, Didier

    2007-01-01

    The purpose of our study was to evaluate the role of MRI in demonstrating the precise nature of papillary renal tumors (P RCC) and its potential application to select patients for partial surgery. Ninety-seven tumors less than or equal to 3 cm in size [55 papillary renal cell carcinoma - 42 clear cell renal carcinoma (CC RCC)] were preoperatively evaluated by MRI. Imaging findings were assessed with a special focus on the aspect of the tumoral process. Correlations were performed with pathologic staging after surgery. At pathology, 92 tumors were established to be staged p T1 and 5 were p T3 (3 cases of CC RCC and 2 cases of P RCC). Ninety-four percent of papillary tumors exhibited low signal intensity with homogeneous pattern on T2-weighted images. All clear cell carcinoma were hyperintense and heterogeneous on T2-weighted sequence. Enhancement was lower and delayed in the papillary type in comparison with the clear cell type. MRI is accurate enough to predict the 'histologic' nature of papillary renal carcinoma. It is an additional argument to propose that the tumor can be removed by partial surgery. (orig.)

  16. Rhinosporidiosis: A Rare Cause of Proptosis and an Imaging Dilemma for Sinonasal Masses

    Directory of Open Access Journals (Sweden)

    Amit Kumar Dey

    2016-01-01

    Full Text Available Background. Rhinosporidiosis is a common disease entity in tropical countries; however, it can be encountered in other parts of the world as well due to increasing medical tourism. It may mimic other more malignant and vigorous pathologies of the involved part. Case Report. We present a case of a 36-year-old male presenting with proptosis due to involvement of nasolacrimal duct which is rare. We will discuss typical CT and MRI features of the disease which were present in the case. Conclusion. For a surgeon and a radiologist, this is a necessary differential to be kept in mind for sinonasal masses. CT and MRI are invaluable investigations. However, FNAC is confirmatory. Both clinical and radiological aspects are required to reach correct diagnosis.

  17. Characterization of adrenal masses: can image replace biopsy?; Charakterisierung von Nebennierenraumforderungen. Kann die Bildgebung die Biopsie ersetzen?

    Energy Technology Data Exchange (ETDEWEB)

    Heinz-Peer, G.; Hoenigschnabel, S.; Lechner, G. [Universtaetsklinik fuer Radiodiagnostik, Abt. Chirurgische Faecher, Wien (Austria)]|[Ludwig Boltzmann-Inst. fuer Radiologische Tumorforschung, Wien (Austria); Niederle, B. [Universitaetsklinik fuer Chirurgie, Univ. Wien (Austria)

    1999-07-01

    This paper describes the diagnostic value of new imaging techniques in characterization of adrenal masses and evaluates the role of adrenal biopsy. For differentiation of benign and malignant adrenal lesions, sensitivities and specificities of 85-100% can be reached by unenhanced computed tomography (CT) methods, chemical shift techniques in magnetic resonance imaging (MRI), delayed enhanced CT techniques, and by evaluation of wash-out curves in contrast-enhanced CT. The diagnostic value of all CT techniques depends on threshold values. The value of dynamic contrast-enhanced MRI is under discussion and should be reevaluated by using delayed enhance series. Biochemical and scintigraphic methods (NP 59 iodine iodomethyl-norcholesterol and MIBG meta-iodobenzylguanidine scintigrams) are valuable for the diagnosis of functional adrenal masses; however, they do not allow differentiation of benign and malignant tumors. According to excellent results of new imaging techniques in characterization of adrenal masses, the indications for fine-needle aspiration biopsy have already regressed, as have complications associated with this invasive technique. (orig.) [Deutsch] Diese Arbeit beschreibt die Moeglichkeiten der Charakterisierung von Nebennierenlaesionen durch die Bildgebung von neuen Untersuchungstechniken und evaluiert den geaenderten Stellenwert der Nebennierenbiopsie. Mittels der nativen Computertomographie (CT), der Chemical-Shift-Technik der Magnetresonanztomographie (MRT) oder Dichtemessungen in CT-Kontrastmittelspaetserien bzw. der Bestimmung des prozentuellen Dichteverlustes in CT-Kontrastmittelserien koennen in der Differenzierung von benignen und malignen Nebennierenlaesionen Sensitivitaeten und Spezifitaeten von 85%-100% erreicht werden. Die diagnostische Wertigkeit der CT-Techniken ist abhaengig von der Definition eines Schwellenwertes. Die Wertigkeit der dynamischen KM-verstaerkten MRT wird derzeit unterschiedlich beurteilt und sollte anhand verbesserter

  18. The social image of drinking - mass media campaigns may inadvertently increase binge drinking.

    Science.gov (United States)

    Zimmermann, Friederike; Kohlmann, Karoline; Monter, Anne; Ameis, Nina

    2017-10-01

    Mass media campaigns that promote responsible drinking are rarely tested for their usefulness in reducing heavy alcohol consumption. Existing campaigns that appeal to responsible drinking while simultaneously displaying young people in social drinking situations may even have paradoxical effects. To examine such possible effects, we drew on a real-world media campaign, which we systematically modified on the basis of recent prototype research. We pilot tested questionnaires (using n = 41 participants), developed two different sets of posters in the style of an existing campaign (n = 39) and investigated their effectiveness (n = 102). In the main study, young men were randomly assigned to one of three conditions: sociable or unsociable binge drinker prototype condition or a control group. Outcome variables were intention, behavioural willingness, attitude, subjective norm, self-efficacy, prototype evaluation and prototype similarity with respect to binge drinking. Binge drinking as a habit was included to control for the fact that habitual drinking in social situations is hard to overcome and poses a particular challenge to interventions. The manipulation check showed that the experimental variation (sociable vs. unsociable drinker prototype condition) was successful. Results of the main study showed that the sociable drinker prototype condition resulted in a higher willingness and - for those with less of a habit - a higher intention to binge drink the next weekend. The unsociable drinker prototype condition had no effects. The results imply that the social components of mass media campaigns might inadvertently exacerbate binge drinking in young men. We therefore advocate against campaigns including aspects of alcohol consumption that might be positively associated with drinker prototype perception. Finally, we provide suggestions for future research.

  19. Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses

    Directory of Open Access Journals (Sweden)

    Wojcinski S

    2013-09-01

    Full Text Available Sebastian Wojcinski,1 Kathrin Brandhorst,2 Gelareh Sadigh,3 Peter Hillemanns,1 Friedrich Degenhardt2 1Department of Obstetrics and Gynecology, Hannover Medical School, Hannover, Germany; 2Department of Obstetrics and Gynecology, Franziskus Hospital, Bielefeld, Germany; 3Department of Radiology, Emory University, Atlanta, GA, USA Abstract: Acoustic radiation force impulse imaging (ARFI with Virtual Touch™ tissue quantification (VTTQ enables the determination of shear wave velocity (SWV in meters per second (m/s. The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s (P < 0.001. Focusing on breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s". Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s (P < 0.001. The best diagnostic accuracy (75.9% was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved. Keywords: ARFI VTTQ, elastography, ultrasound, breast imaging

  20. Co-Registered In Situ Secondary Electron and Mass Spectral Imaging on the Helium Ion Microscope Demonstrated Using Lithium Titanate and Magnesium Oxide Nanoparticles.

    Science.gov (United States)

    Dowsett, D; Wirtz, T

    2017-09-05

    The development of a high resolution elemental imaging platform combining coregistered secondary ion mass spectrometry and high resolution secondary electron imaging is reported. The basic instrument setup and operation are discussed and in situ image correlation is demonstrated on a lithium titanate and magnesium oxide nanoparticle mixture. The instrument uses both helium and neon ion beams generated by a gas field ion source to irradiate the sample. Both secondary electrons and secondary ions may be detected. Secondary ion mass spectrometry (SIMS) is performed using an in-house developed double focusing magnetic sector spectrometer with parallel detection. Spatial resolutions of 10 nm have been obtained in SIMS mode. Both the secondary electron and SIMS image data are very surface sensitive and have approximately the same information depth. While the spatial resolutions are approximately a factor of 10 different, switching between the different images modes may be done in situ and extremely rapidly, allowing for simple imaging of the same region of interest and excellent coregistration of data sets. The ability to correlate mass spectral images on the 10 nm scale with secondary electron images on the nanometer scale in situ has the potential to provide a step change in our understanding of nanoscale phenomena in fields from materials science to life science.

  1. Magnetic Resonance Imaging in the measurement of whole body muscle mass: A comparison of interval gap methods

    International Nuclear Information System (INIS)

    Hellmanns, K.; McBean, K.; Thoirs, K.

    2015-01-01

    Purpose: Magnetic Resonance Imaging (MRI) is commonly used in body composition research to measure whole body skeletal muscle mass (SM). MRI calculation methods of SM can vary by analysing the images at different slice intervals (or interval gaps) along the length of the body. This study compared SM measurements made from MRI images of apparently healthy individuals using different interval gap methods to determine the error associated with each technique. It was anticipated that the results would inform researchers of optimum interval gap measurements to detect a predetermined minimum change in SM. Methods: A method comparison study was used to compare eight interval gap methods (interval gaps of 40, 50, 60, 70, 80, 100, 120 and 140 mm) against a reference 10 mm interval gap method for measuring SM from twenty MRI image sets acquired from apparently healthy participants. Pearson product-moment correlation analysis was used to determine the association between methods. Total error was calculated as the sum of the bias (systematic error) and the random error (limits of agreement) of the mean differences. Percentage error was used to demonstrate proportional error. Results: Pearson product-moment correlation analysis between the reference method and all interval gap methods demonstrated strong and significant associations (r > 0.99, p < 0.0001). The 40 mm interval gap method was comparable with the 10 mm interval reference method and had a low error (total error 0.95 kg, −3.4%). Analysis methods using wider interval gap techniques demonstrated larger errors than reported for dual-energy x-ray absorptiometry (DXA), a technique which is more available, less expensive, and less time consuming than MRI analysis of SM. Conclusions: Researchers using MRI to measure SM can be confident in using a 40 mm interval gap technique when analysing the images to detect minimum changes less than 1 kg. The use of wider intervals will introduce error that is no better

  2. Using Local Event Tomography to Image Changes in the Rock Mass in the Kiirunavaara Iron Ore Mine, Northern Sweden

    Science.gov (United States)

    Lund, B.; Berglund, K.; Tryggvason, A.; Dineva, S.; Jonsson, L.

    2017-12-01

    Although induced seismic events in a mining environment are a potential hazard, they can be used to gain information about the rock mass in the mine which otherwise would be very difficult to obtain. In this study we use approximately 1.2 million mining induced seismic events in the Kiirunavaara iron ore mine in northernmost Sweden to image the rock mass using local event travel-time tomography. The Kiirunavaara mine is the largest underground iron ore mine in the world. The ore body is a magnetite sheet of 4 km length, with an average thickness of 80 m, which dips approximately 55° to the east. The events are of various origins such as shear slip on fractures, non-shear events and blasts, with magnitudes of up to 2.5. We use manually picked P- and S-wave arrival times from the routine processing in the tomography and we require that both phases are present at at least five geophones. For the tomography we use the 3D local earthquake tomography code PStomo_eq (Tryggvason et al., 2002), which we adjusted to the mining scale. The tomographic images show clearly defined regions of high and low velocities. Prominent low S-velocity zones are associated with mapped clay zones. Regions of ore where mining is ongoing and the near-ore tunnel infrastructure in the foot-wall also show generally low P- and S-velocities. The ore at depths below the current mining levels is imaged both as a low S-velocity zone but even more pronounced as a high Vp/Vs ratio zone. The tomography shows higher P- and S-velocities in the foot-wall away from the areas of mine infrastructure. We relocate all 1.2 million events in the new 3D velocity model. The relocation significantly enhances the clarity of the event distribution in space and we can much more easily identify seismically active structures, such as e.g. the deformation of the ore passes. The large number of events makes it possible to do detailed studies of the temporal evolution of stability in the mine. We present preliminary results

  3. Effect of Aging and Surface Interactions on the Diffusion of Endogenous Compounds in Latent Fingerprints Studied by Mass Spectrometry Imaging.

    Science.gov (United States)

    O'Neill, Kelly C; Lee, Young Jin

    2018-05-01

    The ability to determine the age of fingerprints would be immeasurably beneficial in criminal investigations. We explore the possibility of determining the age of fingerprints by analyzing various compounds as they diffuse from the ridges to the valleys of fingerprints using matrix-assisted laser desorption/ionization mass spectrometry imaging. The diffusion of two classes of endogenous fingerprint compounds, fatty acids and triacylglycerols (TGs), was studied in fresh and aged fingerprints on four surfaces. We expected higher molecular weight TGs would diffuse slower than fatty acids and allow us to determine the age of older fingerprints. However, we found interactions between endogenous compounds and the surface have a much stronger impact on diffusion than molecular weight. For example, diffusion of TGs is faster on hydrophilic plain glass or partially hydrophilic stainless steel surfaces, than on a hydrophobic Rain-x treated surface. This result further complicates utilizing a diffusion model to age fingerprints. © 2017 American Academy of Forensic Sciences.

  4. Tracking atmospheric sulphur pollution from the study of Racomitrium lanuginosum mosses in Iceland: A multi-isotope approach (δ34S, 206Pb/204Pb, δ13C and δ15N)

    Science.gov (United States)

    Proust, E.; Widory, D.; Gautason, B.; Rogers, K.; Morrison, J.

    2010-12-01

    Among terrestrial plants, the applicability of mosses as monitoring organisms of atmospheric pollutants is a world-wide accepted technique due to their special biological and morphologic characteristics as nonvascular plants. They are commonly regarded as the best bioindicators of air quality because they can accumulate sulphur (S) and other elements to a far greater level than is necessary for their physiological needs. This study aims at using different isotope systematics δ34S, 206Pb/204Pb, δ13C and δ15N) to help understand the origin of S in the atmophsere of Reykjavik and its vicinity, and especially the potential contribution of surrounding geothermal plants. The selected Icelandic woolly fringe moss (Racomitrium lanuginosum (Hedw.) Brid.) is extremely common in lava fields and gravely and stony areas. Samples were taken in four distinct sampling sites around the city of Reykjavik: Bláfjöll area (south-eastern suburb of the city), and close to three power plants: Hellisheioarvirkjun (northern suburb of the city), Svartsengi (south-western suburb of the city) and Nesjavellir (north-eastern suburb of the city). Results show that, whatever the sampling context is, S is controlled by a binary mixing, between i) a high δ34S (around 16‰) end-member, characteristic of mosses from Hellisheioarvirkjun, and ii) a low δ34S (around -2‰) end-member, characteristic of mosses from Nesjavellir. The multi-isotope approach, confirms this binary relation and helps to constrain the different end-members involved.

  5. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  6. Assessment of dynamic contrast-enhanced magnetic resonance imaging in the differentiation of malignant from benign orbital masses

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Ying [Department of Radiology, Shanghai Ninth People' s Hospital, Affiliated to JiaoTong University School of Medicine, Shanghai 200011 (China); Kuai, Xin-Ping [Department of Radiology, Changshu Second People' s Hospital, Jiangsu Province 215500 (China); Department of Radiology, Changzheng Hospital, Affiliated to Second Military Medical University, Shanghai 200003 (China); Chen, Xiao-Song [Comprehensive Breast Health Center, Ruijin Hospital Shanghai Jiaotong University School of Medicine, 197 Ruijin Er Road, Shanghai 20025 (China); Tao, Xiao-Feng, E-mail: cjr.taoxiaofeng@vip.163.com [Department of Radiology, Shanghai Ninth People' s Hospital, Affiliated to JiaoTong University School of Medicine, Shanghai 200011 (China)

    2013-09-15

    Objective: Dynamic contrast enhanced MR imaging (DCE-MRI) allows imaging of the physiology of the microcirculation. The purpose of this study was to determine the diagnostic efficacy of time intensity curve (TIC) and DCE parameters for characterization of orbital masses. Methods: Fifty-nine patients with untreated orbital lesions underwent DCE-MRI before surgery. For each lesion, peak height (PH), maximum enhancement ratio (ER{sub max}), time of peak enhancement (T{sub peak}) and maximum rise slope (Slope{sub max}) were plotted and calculated. Receiver operator characteristics (ROC) analysis was conducted to assess the appropriate cut-off value. Results: All 26 lesions that demonstrated persistent pattern (type-I) TICs were benign. Most of the masses with the washout pattern (type-III) TIC were malignant (10/14), including lymphoma (n = 6) and melanoma (n = 4). The Slope{sub max} of benign lesions was statistically lower than malignant ones, while the ER{sub max} and T{sub peak} values of benign lesions were significantly higher. No statistical difference was found in PH (P = 0.121). The AUC for ER{sub max}, T{sub peak} and Slope{sub max} in differentiating benign orbital lesions from malignant ones were 0.683, 0.837 and 0.738, respectively. In the three DCE parameters, Slope{sub max} cut-off value of 1.10 provided the highest sensitivity of 93.8%; however, the corresponding specificity was low (58.1%). The ER{sub max} cut-off value of 1.37 and T{sub peak} cut-off value of 35.14 respectively offered the best diagnostic performances. Conclusion: DCE-MRI, especially the qualitative TIC pattern and quantitative value of Slope{sub max}, ER{sub max} and T{sub peak}, could be a complementary investigation in distinguishing malignant orbital tumor from benign ones.

  7. Characterization of lipidic markers of chondrogenic differentiation using mass spectrometry imaging.

    Science.gov (United States)

    Rocha, Beatriz; Cillero-Pastor, Berta; Eijkel, Gert; Bruinen, Anne L; Ruiz-Romero, Cristina; Heeren, Ron M A; Blanco, Francisco J

    2015-02-01

    Mesenchymal stem cells (MSC) are an interesting alternative for cell-based therapy of cartilage defects attributable to their capacity to differentiate toward chondrocytes in the process termed chondrogenesis. The metabolism of lipids has recently been associated with the modulation of chondrogenesis and also with the development of pathologies related to cartilage degeneration. Information about the distribution and modulation of lipids during chondrogenesis could provide a panel of putative chondrogenic markers. Thus, the discovery of new lipid chondrogenic markers could be highly valuable for improving MSC-based cartilage therapies. In this work, MS imaging was used to characterize the spatial distribution of lipids in human bone marrow MSCs during the first steps of chondrogenic differentiation. The analysis of MSC micromasses at days 2 and 14 of chondrogenesis by MALDI-MSI led to the identification of 20 different lipid species, including fatty acids, sphingolipids, and phospholipids. Phosphocholine, several sphingomyelins, and phosphatidylcholines were found to increase during the undifferentiated chondrogenic stage. A particularly detected lipid profile was verified by TOF secondary ion MS. Using this technology, a higher intensity of phosphocholine-related ions was observed in the peripheral region of the micromasses collected at day 14. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Different localization patterns of anthocyanin species in the pericarp of black rice revealed by imaging mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Yukihiro Yoshimura

    Full Text Available Black rice (Oryza sativa L. Japonica contains high levels of anthocyanins in the pericarp and is considered an effective health-promoting food. Several studies have identified the molecular species of anthocyanins in black rice, but information about the localization of each anthocyanin species is limited because methodologies for investigating the localization such as determining specific antibodies to anthocyanin, have not yet been developed Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS is a suitable tool for investigating the localization of metabolites. In this study, we identified 7 species of anthocyanin monoglycosides and 2 species of anthocyanin diglycosides in crude extracts from black rice by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS analysis. We also analyzed black rice sections by MALDI-IMS and found 2 additional species of anthocyanin pentosides and revealed different localization patterns of anthocyanin species composed of different sugar moieties. Anthocyanin species composed of a pentose moiety (cyanidin-3-O-pentoside and petunidin-3-O-pentoside were localized in the entire pericarp, whereas anthocyanin species composed of a hexose moiety (cyanidin-3-O-hexoside and peonidin-3-O-hexoside were focally localized in the dorsal pericarp. These results indicate that anthocyanin species composed of different sugar moieties exhibit different localization patterns in the pericarp of black rice. This is the first detailed investigation into the localization of molecular species of anthocyanins by MALDI-IMS.

  9. Identification and localization of trauma-related biomarkers using matrix assisted laser desorption/ionization imaging mass spectrometry

    Science.gov (United States)

    Jones, Kirstin; Reilly, Matthew A.; Glickman, Randolph D.

    2017-02-01

    Current treatments for ocular and optic nerve trauma are largely ineffective and may have adverse side effects; therefore, new approaches are needed to understand trauma mechanisms. Identification of trauma-related biomarkers may yield insights into the molecular aspects of tissue trauma that can contribute to the development of better diagnostics and treatments. The conventional approach for protein biomarker measurement largely relies on immunoaffinity methods that typically can only be applied to analytes for which antibodies or other targeting means are available. Matrix assisted laser-assisted desorption/ionization imaging mass spectrometry (MALDI-IMS) is a specialized application of mass spectrometry that not only is well suited to the discovery of novel or unanticipated biomarkers, but also provides information about the spatial localization of biomarkers in tissue. We have been using MALDI-IMS to find traumarelated protein biomarkers in retina and optic nerve tissue from animal models subjected to ocular injury produced by either blast overpressure or mechanical torsion. Work to date by our group, using MALDI-IMS, found that the pattern of protein expression is modified in the injured ocular tissue as soon as 24 hr post-injury, compared to controls. Specific proteins may be up- or down-regulated by trauma, suggesting different tissue responses to a given injury. Ongoing work is directed at identifying the proteins affected and mapping their expression in the ocular tissue, anticipating that systematic analysis can be used to identify targets for prospective therapies for ocular trauma.

  10. Mass Spectrometry Imaging in Nanomedicine: Unraveling the Potential of MSI for the Detection of Nanoparticles in Neuroscience.

    Science.gov (United States)

    Barre, Florian P Y; Heeren, Ron M A; Potocnik, Nina Ogrinc

    2017-01-01

    Mass spectrometry imaging (MSI) can uniquely detect thousands of compounds allowing both their identification and localization within biological tissue samples. MSI is an interdisciplinary science that crosses the borders of physics, chemistry and biology, and enables local molecular analysis at a broad range of length scales: From the subcellular level to whole body tissue sections. The spatial resolution of some mass spectrometers now allows nano-scale research, crucial for studies in nanomedicine. Recent developments in MSI have enabled the optimization and localization of drug delivery with nanoparticles within the body and in specific organs such as kidney, liver and brain. Combining MSI with nanomedicine has vast potential, specifically in the treatment of neurological disorders, where effective drug delivery has been hampered by the blood-brain barrier. This review provides an introduction to MSI and its different technologies, with the application of MSI to nanomedicine and the different possibilities that MSI offers to study molecular signals in the brain. Finally, we provide an outlook for the future and exciting potential of MSI in nanoparticle-related research. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Imaging Mass Spectrometry Revealed the Accumulation Characteristics of the 2-Nitroimidazole-Based Agent "Pimonidazole" in Hypoxia.

    Directory of Open Access Journals (Sweden)

    Yukiko Masaki

    Full Text Available Hypoxia, or low oxygen concentration, is a key factor promoting tumor progression and angiogenesis and resistance of cancer to radiotherapy and chemotherapy. 2-Nitroimidazole-based agents have been widely used in pathological and nuclear medicine examinations to detect hypoxic regions in tumors; in particular, pimonidazole is used for histochemical staining of hypoxic regions. It is considered to accumulate in hypoxic cells via covalent binding with macromolecules or by forming reductive metabolites after reduction of its nitro group. However, the detailed mechanism of its accumulation remains unknown. In this study, we investigated the accumulation mechanism of pimonidazole in hypoxic tumor tissues in a mouse model by mass spectrometric analyses including imaging mass spectrometry (IMS. Pimonidazole and its reductive metabolites were observed in the tumor tissues. However, their locations in the tumor sections were not similar to the positively stained areas in pimonidazole-immunohistochemistry, an area considered hypoxic. The glutathione conjugate of reduced pimonidazole, a low-molecular-weight metabolite of pimonidazole, was found in tumor tissues by LC-MS analysis, and our IMS study determined that the intratumor localization of the glutathione conjugate was consistent with the area positively immunostained for pimonidazole. We also found complementary localization of the glutathione conjugate and reduced glutathione (GSH, implying that formation of the glutathione conjugate occurred in the tumor tissue. These results suggest that in hypoxic tumor cells, pimonidazole is reduced at its nitro group, followed by conjugation with GSH.

  12. Combined Mass Spectrometry Imaging and Top-down Microproteomics Reveals Evidence of a Hidden Proteome in Ovarian Cancer.

    Science.gov (United States)

    Delcourt, Vivian; Franck, Julien; Leblanc, Eric; Narducci, Fabrice; Robin, Yves-Marie; Gimeno, Jean-Pascal; Quanico, Jusal; Wisztorski, Maxence; Kobeissy, Firas; Jacques, Jean-François; Roucou, Xavier; Salzet, Michel; Fournier, Isabelle

    2017-07-01

    Recently, it was demonstrated that proteins can be translated from alternative open reading frames (altORFs), increasing the size of the actual proteome. Top-down mass spectrometry-based proteomics allows the identification of intact proteins containing post-translational modifications (PTMs) as well as truncated forms translated from reference ORFs or altORFs. Top-down tissue microproteomics was applied on benign, tumor and necrotic-fibrotic regions of serous ovarian cancer biopsies, identifying proteins exhibiting region-specific cellular localization and PTMs. The regions of interest (ROIs) were determined by MALDI mass spectrometry imaging and spatial segmentation. Analysis with a customized protein sequence database containing reference and alternative proteins (altprots) identified 15 altprots, including alternative G protein nucleolar 1 (AltGNL1) found in the tumor, and translated from an altORF nested within the GNL1 canonical coding sequence. Co-expression of GNL1 and altGNL1 was validated by transfection in HEK293 and HeLa cells with an expression plasmid containing a GNL1-FLAG (V5) construct. Western blot and immunofluorescence experiments confirmed constitutive co-expression of altGNL1-V5 with GNL1-FLAG. Taken together, our approach provides means to evaluate protein changes in the case of serous ovarian cancer, allowing the detection of potential markers that have never been considered. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  13. The expression profile of phosphatidylinositol in high spatial resolution imaging mass spectrometry as a potential biomarker for prostate cancer.

    Directory of Open Access Journals (Sweden)

    Takayuki Goto

    Full Text Available High-resolution matrix-assisted laser desorption/ionization imaging mass spectrometry (HR-MALDI-IMS is an emerging application for the comprehensive and detailed analysis of the spatial distribution of ionized molecules in situ on tissue slides. HR-MALDI-IMS in negative mode in a mass range of m/z 500-1000 was performed on optimal cutting temperature (OCT compound-embedded human prostate tissue samples obtained from patients with prostate cancer at the time of radical prostatectomy. HR-MALDI-IMS analysis of the 14 samples in the discovery set identified 26 molecules as highly expressed in the prostate. Tandem mass spectrometry (MS/MS showed that these molecules included 14 phosphatidylinositols (PIs, 3 phosphatidylethanolamines (PEs and 3 phosphatidic acids (PAs. Among the PIs, the expression of PI(18:0/18:1, PI(18:0/20:3 and PI(18:0/20:2 were significantly higher in cancer tissue than in benign epithelium. A biomarker algorithm for prostate cancer was formulated by analyzing the expression profiles of PIs in cancer tissue and benign epithelium of the discovery set using orthogonal partial least squares discriminant analysis (OPLS-DA. The sensitivity and specificity of this algorithm for prostate cancer diagnosis in the 24 validation set samples were 87.5 and 91.7%, respectively. In conclusion, HR-MALDI-IMS identified several PIs as being more highly expressed in prostate cancer than benign prostate epithelium. These differences in PI expression profiles may serve as a novel diagnostic tool for prostate cancer.

  14. Top-down proteomics with mass spectrometry imaging: a pilot study towards discovery of biomarkers for neurodevelopmental disorders.

    Directory of Open Access Journals (Sweden)

    Hui Ye

    Full Text Available In the developing mammalian brain, inhibition of NMDA receptor can induce widespread neuroapoptosis, inhibit neurogenesis and cause impairment of learning and memory. Although some mechanistic insights into adverse neurological actions of these NMDA receptor antagonists exist, our understanding of the full spectrum of developmental events affected by early exposure to these chemical agents in the brain is still limited. Here we attempt to gain insights into the impact of pharmacologically induced excitatory/inhibitory imbalance in infancy on the brain proteome using mass spectrometric imaging (MSI. Our goal was to study changes in protein expression in postnatal day 10 (P10 rat brains following neonatal exposure to the NMDA receptor antagonist dizocilpine (MK801. Analysis of rat brains exposed to vehicle or MK801 and comparison of their MALDI MS images revealed differential relative abundances of several proteins. We then identified these markers such as ubiquitin, purkinje cell protein 4 (PEP-19, cytochrome c oxidase subunits and calmodulin, by a combination of reversed-phase (RP HPLC fractionation and top-down tandem MS platform. More in-depth large scale study along with validation experiments will be carried out in the future. Overall, our findings indicate that a brief neonatal exposure to a compound that alters excitatory/inhibitory balance in the brain has a long term effect on protein expression patterns during subsequent development, highlighting the utility of MALDI-MSI as a discovery tool for potential biomarkers.

  15. A new classification method for MALDI imaging mass spectrometry data acquired on formalin-fixed paraffin-embedded tissue samples.

    Science.gov (United States)

    Boskamp, Tobias; Lachmund, Delf; Oetjen, Janina; Cordero Hernandez, Yovany; Trede, Dennis; Maass, Peter; Casadonte, Rita; Kriegsmann, Jörg; Warth, Arne; Dienemann, Hendrik; Weichert, Wilko; Kriegsmann, Mark

    2017-07-01

    Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) shows a high potential for applications in histopathological diagnosis, and in particular for supporting tumor typing and subtyping. The development of such applications requires the extraction of spectral fingerprints that are relevant for the given tissue and the identification of biomarkers associated with these spectral patterns. We propose a novel data analysis method based on the extraction of characteristic spectral patterns (CSPs) that allow automated generation of classification models for spectral data. Formalin-fixed paraffin embedded (FFPE) tissue samples from N=445 patients assembled on 12 tissue microarrays were analyzed. The method was applied to discriminate primary lung and pancreatic cancer, as well as adenocarcinoma and squamous cell carcinoma of the lung. A classification accuracy of 100% and 82.8%, resp., could be achieved on core level, assessed by cross-validation. The method outperformed the more conventional classification method based on the extraction of individual m/z values in the first application, while achieving a comparable accuracy in the second. LC-MS/MS peptide identification demonstrated that the spectral features present in selected CSPs correspond to peptides relevant for the respective classification. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Intrasplenic masses of ''preserved'' functioning splenic tissue in sickle cell disease: correlation of imaging findings (CT, ultrasound, MRI, and nuclear scintigraphy)

    International Nuclear Information System (INIS)

    Levin, T.L.; Berdon, W.E.; Haller, J.O.; Ruzal-Shapiro, C.; Hurlet-Jenson, A.

    1996-01-01

    Purpose. We studied six patients with sickle cell disease (SSD), five homozygous for sickle cell anemia and one with sickle beta-thalassemia, in whom rounded intrasplenic masses proved to be preserved functioning splenic tissue. Materials and methods. Available images including computed tomography, ultrasonography, bone scans (Tc-99m MDP), liver spleen scans (Tc-99m sulfur colloid), and MRI were evaluated. Results. The masses were low density on CT (in an otherwise calcified spleen), hypoechoic relative to the echogenic spleen on US, and had the imaging characteristics of normal spleen on MRI. They failed to accumulate Tc-99m MDP but did demonstrate uptake of Tc-99m sulfur colloid. Conclusion. In a patient with SSD and intrasplenic masses, proper correlation of multiple imaging modalities will establish the diagnosis of functioning splenic tissue and avoid mistaken diagnosis of splenic abscess or infarction. (orig.). With 2 figs., 1 tab

  17. Intrasplenic masses of ``preserved`` functioning splenic tissue in sickle cell disease: correlation of imaging findings (CT, ultrasound, MRI, and nuclear scintigraphy)

    Energy Technology Data Exchange (ETDEWEB)

    Levin, T.L. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Berdon, W.E. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Haller, J.O. [Department of Radiology, SUNY Downstate Medical Center, Brooklyn, New York (United States); Ruzal-Shapiro, C. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Hurlet-Jenson, A. [Department of Pediatrics, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, New York (United States)

    1996-09-01

    Purpose. We studied six patients with sickle cell disease (SSD), five homozygous for sickle cell anemia and one with sickle beta-thalassemia, in whom rounded intrasplenic masses proved to be preserved functioning splenic tissue. Materials and methods. Available images including computed tomography, ultrasonography, bone scans (Tc-99m MDP), liver spleen scans (Tc-99m sulfur colloid), and MRI were evaluated. Results. The masses were low density on CT (in an otherwise calcified spleen), hypoechoic relative to the echogenic spleen on US, and had the imaging characteristics of normal spleen on MRI. They failed to accumulate Tc-99m MDP but did demonstrate uptake of Tc-99m sulfur colloid. Conclusion. In a patient with SSD and intrasplenic masses, proper correlation of multiple imaging modalities will establish the diagnosis of functioning splenic tissue and avoid mistaken diagnosis of splenic abscess or infarction. (orig.). With 2 figs., 1 tab.

  18. Brimstone chemistry under laser light assists mass spectrometric detection and imaging the distribution of arsenic in minerals.

    Science.gov (United States)

    Lal, Swapnil; Zheng, Zhaoyu; Pavlov, Julius; Attygalle, Athula B

    2018-05-23

    Singly charged As2n+1 ion clusters (n = 2-11) were generated from elemental arsenic by negative-ion laser-ablation mass spectrometry. The overall abundance of the gaseous As ions generated upon laser irradiation was enhanced nearly a hundred times when As-bearing samples were admixed with sulfur. However, sulfur does not act purely as an inert matrix: irradiating arsenic-sulfur mixtures revealed a novel pathway to generate and detect a series of [AsSn]- clusters (n = 2-6). Intriguingly, the spectra recorded from As2O3, NaAsO2, Na3AsO4, cacodylic acid and 3-amino-4-hydroxyphenylarsonic acid together with sulfur as the matrix were remarkably similar to that acquired from an elemental arsenic and sulfur mixture. This result indicated that arsenic sulfide cluster-ions are generated directly from arsenic compounds by a hitherto unknown pathway. The mechanism of elemental sulfur extracting chemically bound arsenic from compounds and forming [AsSn]- clusters is enigmatic; however, this discovery has a practical value as a general detection method for arsenic compounds. For example, the method was employed for the detection of As in its minerals, and for the imaging of arsenic distribution in minerals such as domeykite. LDI-MS data recorded from a latent image imprinted on a piece of paper from a flat mineral surface, and wetting the paper with a solution of sulfur, enabled the localization of arsenic in the mineral. The distribution of As was visualized as false-color images by extracting from acquired data the relative intensities of m/z 139 (AsS2-) and m/z 171 (AsS3-) ions.

  19. Quantitative analysis of multiple high-resolution mass spectrometry images using chemometric methods: quantitation of chlordecone in mouse liver.

    Science.gov (United States)

    Mohammadi, Saeedeh; Parastar, Hadi

    2018-05-15

    In this work, a chemometrics-based strategy is developed for quantitative mass spectrometry imaging (MSI). In this regard, quantification of chlordecone as a carcinogenic organochlorinated pesticide (C10Cll0O) in mouse liver using the matrix-assisted laser desorption ionization MSI (MALDI-MSI) method is used as a case study. The MSI datasets corresponded to 1, 5 and 10 days of mouse exposure to the standard chlordecone in the quantity range of 0 to 450 μg g-1. The binning approach in the m/z direction is used to group high resolution m/z values and to reduce the big data size. To consider the effect of bin size on the quality of results, three different bin sizes of 0.25, 0.5 and 1.0 were chosen. Afterwards, three-way MSI data arrays (two spatial and one m/z dimensions) for seven standards and four unknown samples were column-wise augmented with m/z values as the common mode. Then, these datasets were analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) using proper constraints. The resolved mass spectra were used for identification of chlordecone in the presence of a complex background and interference. Additionally, the augmented spatial profiles were post-processed and 2D images for each component were obtained in calibration and unknown samples. The sum of these profiles was utilized to set the calibration curve and to obtain the analytical figures of merit (AFOMs). Inspection of the results showed that the lower bin size (i.e., 0.25) provides more accurate results. Finally, the obtained results by MCR for three datasets were compared with those of gas chromatography-mass spectrometry (GC-MS) and MALDI-MSI. The results showed that the MCR-assisted method gives a higher amount of chlordecone than MALDI-MSI and a lower amount than GC-MS. It is concluded that a combination of chemometric methods with MSI can be considered as an alternative way for MSI quantification.

  20. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    Science.gov (United States)

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  1. Prospective Out-of-ecliptic White-light Imaging of Coronal Mass Ejections Traveling through the Corona and Heliosphere

    Science.gov (United States)

    Xiong, Ming; Davies, Jackie A.; Harrison, Richard A.; Zhou, Yufen; Feng, Xueshang; Xia, Lidong; Li, Bo; Liu, Ying D.; Hayashi, Keiji; Li, Huichao; Yang, Liping

    2018-01-01

    The in-flight performance of the Coriolis/SMEI and STEREO/HI instruments substantiates the high-technology readiness level of white-light (WL) imaging of coronal mass ejections (CMEs) in the inner heliosphere. The WL intensity of a propagating CME is jointly determined by its evolving mass distribution and the fixed Thomson-scattering geometry. From their in-ecliptic viewpoints, SMEI and HI, the only heliospheric imagers that have been flown to date, integrate the longitudinal dimension of CMEs. In this paper, using forward magnetohydrodynamic modeling, we synthesize the WL radiance pattern of a typical halo CME viewed from an out-of-ecliptic (OOE) vantage point. The major anatomical elements of the CME identified in WL imagery are a leading sheath and a trailing ejecta; the ejecta-driven sheath is the brightest feature of the CME. The sheath, a three-dimensional (3D) dome-like density structure, occupies a wide angular extent ahead of the ejecta itself. The 2D radiance pattern of the sheath depends critically on viewpoint. For a CME modeled under solar minimum conditions, the WL radiance pattern of the sheath is generally a quasi-straight band when viewed from an in-ecliptic viewpoint and a semicircular arc from an OOE viewpoint. The dependence of the radiance pattern of the ejecta-driven sheath on viewpoint is attributed to the bimodal nature of the 3D background solar wind flow. Our forward-modeling results suggest that OOE imaging in WL radiance can enable (1) a near-ecliptic CME to be continuously tracked from its coronal initiation, (2) the longitudinal span of the CME to be readily charted, and (3) the transporting speed of the CME to be reliably determined. Additional WL polarization measurements can significantly limit the ambiguity of localizing CMEs. We assert that a panoramic OOE view in WL would be highly beneficial in revealing CME morphology and kinematics in the hitherto-unresolved longitudinal dimension and hence for monitoring the propagation and

  2. Development and application of out-of-focus imaging in order to characterize heat and mass exchanges in two-phase flows

    International Nuclear Information System (INIS)

    Lemaitre, P.; Porcheron, E.; Marchand, D.; Nuboer, A.; Bouilloux, L.; Vendel, J.

    2007-01-01

    The aim of this paper is to present the capacity of the out-of-focus imaging in order to measure droplets size in presence of heat and mass exchanges. It is supported with optical simulations first based on geometrical optics, and then with the Lorenz-Mie theory. Finally, this technique is applied in presence of heat and mass transfers in the TOSQAN experiment. (authors)

  3. Considering an Affect Regulation Framework for Examining the Association Between Body Dissatisfaction and Positive Body Image in Black Older Adolescent Females: Does Body Mass Index Matter?

    Science.gov (United States)

    Butler-Ajibade, Phoebe; Robinson, Seronda A.

    2014-01-01

    The present study provided an initial evaluation of an affect regulation model describing the association between body dissatisfaction and two contemporary measures of positive body image among 247 Black college-bound older adolescent females. We further tested whether possessing a higher body mass index (BMI) would strengthen these associations. Self-reported height and weight were used to calculate BMI. Respondents also completed a culturally-sensitive figure rating scale along with assessments of body appreciation and body image flexibility. Results indicated a robust positive association between the two measures of positive body image; BMI was the strongest predictor of both body appreciation and body image flexibility with body size discrepancy (current minus ideal) contributing incremental variance to both models tested. Implications for improving our understanding of the association between positive and negative body image and bolstering positive body image to promote health-protective behaviors among Black young women at this developmental juncture are discussed. PMID:25079011

  4. Sex and Age Differences in Body-Image, Self-Esteem, and Body Mass Index in Adolescents and Adults After Single-Ventricle Palliation

    OpenAIRE

    Pike, Nancy A.; Evangelista, Lorraine S.; Doering, Lynn V.; Eastwood, Jo-Ann; Lewis, Alan B.; Child, John S.

    2012-01-01

    Single-ventricle congenital heart disease (SVCHD) requires multiple palliative surgical procedures that leave visible surgical scars and physical deficits, which can alter body-image and self-esteem. This study aimed to compare sex and age differences in body-image, selfesteem, and body mass index (BMI) in adolescents and adults with SVCHD after surgical palliation with those of a healthy control group. Using a comparative, cross-sectional design, 54 adolescent and adult (26 male and 28 femal...

  5. Estimation of thigh muscle mass with magnetic resonance imaging in older adults and people with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Mathur, Sunita; Takai, Karen Pr; Macintyre, Donna L; Reid, Darlene

    2008-02-01

    Quantifying muscle mass is an essential part of physical therapy assessment, particularly in older adults and in people with chronic conditions associated with muscle atrophy. The purposes of this study were to examine the relationship between muscle cross-sectional area (CSA) and volume by use of magnetic resonance imaging (MRI) and to compare anthropometric estimations of midthigh CSA with measurements obtained from MRI. Twenty older adults who were healthy and 20 people with chronic obstructive pulmonary disease (COPD), matched for age, sex, and body mass index, underwent MRI to obtain measurements of thigh muscle CSA and volume. Anthropometric measurements (skinfold thickness and thigh circumference) were used to estimate midthigh CSA. Muscle volumes were significantly lower in the people with COPD than in the older adults who were healthy. Moderate to high correlations were found between midthigh CSA and volume in both groups (r=.61-.94). Anthropometric measurements tended to overestimate midthigh CSA in both the people with COPD (estimated CSA=64.9+/-17.8; actual CSA=48.3+/-10.2 cm(2)) and the older adults who were healthy (estimated quadriceps femoris muscle CSA=65.0+/-14.0; actual CSA=56.8+/-13.5 cm(2)). Furthermore, the estimated quadriceps femoris muscle CSAs were not sensitive enough to detect a difference in muscle size between people with COPD and controls. Thigh circumference alone was not different between groups and showed only low to moderate correlations with muscle volume (r=.19-.47). Muscle CSA measured from a single slice provides a good indication of volume, but the most representative slice should be chosen on the basis of the muscle group of interest. Thigh circumference is not correlated with muscle volume and, therefore, should not be used as an indicator of muscle size. The development of population-specific reference equations for estimating muscle CSA from anthropometric measurements is warranted.

  6. THE PULSATION OF χ CYGNI IMAGED BY OPTICAL INTERFEROMETRY: A NOVEL TECHNIQUE TO DERIVE DISTANCE AND MASS OF MIRA STARS

    International Nuclear Information System (INIS)

    Lacour, S.; Perrin, G.; Haubois, X.; Poncelet, A.; Thiebaut, E.; Meimon, S.; Pedretti, E.; Ridgway, S. T.; Monnier, J. D.; Berger, J. P.; Schuller, P. A.; Woodruff, H.; Le Coroller, H.; Millan-Gabet, R.; Lacasse, M.; Traub, W.

    2009-01-01

    We present infrared interferometric imaging of the S-type Mira star χ Cygni. The object was observed at four different epochs in 2005-2006 with the Infrared-Optical Telescope Array optical interferometer (H band). Images show up to 40% variation in the stellar diameter, as well as significant changes in the limb darkening and stellar inhomogeneities. Model fitting gave precise time-dependent values of the stellar diameter, and reveals presence and displacement of a warm molecular layer. The star radius, corrected for limb darkening, has a mean value of 12.1 mas and shows a 5.1 mas amplitude pulsation. Minimum diameter was observed at phase 0.94 ± 0.01. Maximum temperature was observed several days later at phase 1.02 ± 0.02. We also show that combining the angular acceleration of the molecular layer with CO (Δv = 3) radial velocity measurements yields a 5.9 ± 1.5 mas parallax. The constant acceleration of the CO molecules-during 80% of the pulsation cycle-lead us to argument for a free-falling layer. The acceleration is compatible with a gravitational field produced by a 2.1 +1.5 -0.7 solar mass star. This last value is in agreement with fundamental mode pulsator models. We foresee increased development of techniques consisting in combining radial velocity with interferometric angular measurements, ultimately allowing total mapping of the speed, density, and position of the diverse species in pulsation-driven atmospheres.

  7. Chemometric Analysis of High Molecular Mass Glutenin Subunits and Image Data of Bread Crumb Structure from Croatian Wheat Cultivars

    Directory of Open Access Journals (Sweden)

    Zorica Jurković

    2002-01-01

    Full Text Available The aim of this work is to investigate functional relationships among wheat properties, high molecular mass (weight (HMW glutenin subunits and bread quality produced from eleven Croatian wheat cultivars by chemometric analysis. HMW glutenin subunits were fractionated by sodium dodecylsulfate polyacrylamid gel electrophoresis (SDS-PAGE and subsequently analysed by scanning densitometry in order to quantify HMW glutenin fractions. Wheat properties are characterised by four variables: protein content, sedimentation value, wet gluten and gluten index. Bread quality is assessed by the standard measurement of loaf volume, and visual quality of bread slice is quantified by 8 parameters by the use of computer image analysis. The data matrix with 21 columns (measured variables and 11 rows (cultivars is analysed for determination of number of latent variables. It was found that the first two latent variables account for 92, 85 and 87 % of variance of wheat quality properties, HMW glutenin fractions, and the bread quality parameters, respectively. Classification and functional relationships are discussed from the case data (cultivars and variable projections to the planes of the first two latent variables. Between Glu-D1y proportion and the bread quality parameters (standard parameter loaf volume and bread crumb cell area fraction determined by image analysis the strongest positive correlations are found r = 0.651 and r = 0.885, respectively. Between Glu-B1x proportion and the bread quality parameters the strongest negative correlations are found r =-0.535 and r = –0.841, respectively. The results are discussed in view of possible development of new and improvement of existing wheat cultivars and optimisation of bread production.

  8. The Grism Lens-amplified Survey from Space (GLASS). IV. Mass Reconstruction of the Lensing Cluster Abell 2744 from Frontier Field Imaging and GLASS Spectroscopy

    Science.gov (United States)

    Wang, X.; Hoag, A.; Huang, K.-H.; Treu, T.; Bradač, M.; Schmidt, K. B.; Brammer, G. B.; Vulcani, B.; Jones, T. A.; Ryan, R. E., Jr.; Amorín, R.; Castellano, M.; Fontana, A.; Merlin, E.; Trenti, M.

    2015-09-01

    We present a strong and weak lensing reconstruction of the massive cluster Abell 2744, the first cluster for which deep Hubble Frontier Fields (HFF) images and spectroscopy from the Grism Lens-Amplified Survey from Space (GLASS) are available. By performing a targeted search for emission lines in multiply imaged sources using the GLASS spectra, we obtain five high-confidence spectroscopic redshifts and two tentative ones. We confirm one strongly lensed system by detecting the same emission lines in all three multiple images. We also search for additional line emitters blindly and use the full GLASS spectroscopic catalog to test reliability of photometric redshifts for faint line emitters. We see a reasonable agreement between our photometric and spectroscopic redshift measurements, when including nebular emission in photometric redshift estimations. We introduce a stringent procedure to identify only secure multiple image sets based on colors, morphology, and spectroscopy. By combining 7 multiple image systems with secure spectroscopic redshifts (at 5 distinct redshift planes) with 18 multiple image systems with secure photometric redshifts, we reconstruct the gravitational potential of the cluster pixellated on an adaptive grid, using a total of 72 images. The resulting mass map is compared with a stellar mass map obtained from the deep Spitzer Frontier Fields data to study the relative distribution of stars and dark matter in the cluster. We find that the stellar to total mass ratio varies substantially across the cluster field, suggesting that stars do not trace exactly the total mass in this interacting system. The maps of convergence, shear, and magnification are made available in the standard HFF format.

  9. THE GRISM LENS-AMPLIFIED SURVEY FROM SPACE (GLASS). IV. MASS RECONSTRUCTION OF THE LENSING CLUSTER ABELL 2744 FROM FRONTIER FIELD IMAGING AND GLASS SPECTROSCOPY

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.; Schmidt, K. B.; Jones, T. A. [Department of Physics, University of California, Santa Barbara, CA 93106-9530 (United States); Hoag, A.; Huang, K.-H.; Bradac, M. [Department of Physics, University of California, Davis, CA 95616 (United States); Treu, T. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Brammer, G. B.; Ryan, R. E. Jr. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD, 21218 (United States); Vulcani, B. [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo Institutes for Advanced Study (UTIAS), the University of Tokyo, Kashiwa, 277-8582 (Japan); Amorín, R.; Castellano, M.; Fontana, A.; Merlin, E. [INAF—Osservatorio Astronomico di Roma Via Frascati 33, I-00040 Monte Porzio Catone (Italy); Trenti, M., E-mail: xinwang@physics.ucsb.edu [School of Physics, The University of Melbourne, VIC 3010 (Australia)

    2015-09-20

    We present a strong and weak lensing reconstruction of the massive cluster Abell 2744, the first cluster for which deep Hubble Frontier Fields (HFF) images and spectroscopy from the Grism Lens-Amplified Survey from Space (GLASS) are available. By performing a targeted search for emission lines in multiply imaged sources using the GLASS spectra, we obtain five high-confidence spectroscopic redshifts and two tentative ones. We confirm one strongly lensed system by detecting the same emission lines in all three multiple images. We also search for additional line emitters blindly and use the full GLASS spectroscopic catalog to test reliability of photometric redshifts for faint line emitters. We see a reasonable agreement between our photometric and spectroscopic redshift measurements, when including nebular emission in photometric redshift estimations. We introduce a stringent procedure to identify only secure multiple image sets based on colors, morphology, and spectroscopy. By combining 7 multiple image systems with secure spectroscopic redshifts (at 5 distinct redshift planes) with 18 multiple image systems with secure photometric redshifts, we reconstruct the gravitational potential of the cluster pixellated on an adaptive grid, using a total of 72 images. The resulting mass map is compared with a stellar mass map obtained from the deep Spitzer Frontier Fields data to study the relative distribution of stars and dark matter in the cluster. We find that the stellar to total mass ratio varies substantially across the cluster field, suggesting that stars do not trace exactly the total mass in this interacting system. The maps of convergence, shear, and magnification are made available in the standard HFF format.

  10. A comprehensive high-resolution mass spectrometry approach for characterization of metabolites by combination of ambient ionization, chromatography and imaging methods.

    Science.gov (United States)

    Berisha, Arton; Dold, Sebastian; Guenther, Sabine; Desbenoit, Nicolas; Takats, Zoltan; Spengler, Bernhard; Römpp, Andreas

    2014-08-30

    An ideal method for bioanalytical applications would deliver spatially resolved quantitative information in real time and without sample preparation. In reality these requirements can typically not be met by a single analytical technique. Therefore, we combine different mass spectrometry approaches: chromatographic separation, ambient ionization and imaging techniques, in order to obtain comprehensive information about metabolites in complex biological samples. Samples were analyzed by laser desorption followed by electrospray ionization (LD-ESI) as an ambient ionization technique, by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging for spatial distribution analysis and by high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) for quantitation and validation of compound identification. All MS data were acquired with high mass resolution and accurate mass (using orbital trapping and ion cyclotron resonance mass spectrometers). Grape berries were analyzed and evaluated in detail, whereas wheat seeds and mouse brain tissue were analyzed in proof-of-concept experiments. In situ measurements by LD-ESI without any sample preparation allowed for fast screening of plant metabolites on the grape surface. MALDI imaging of grape cross sections at 20 µm pixel size revealed the detailed distribution of metabolites which were in accordance with their biological function. HPLC/ESI-MS was used to quantify 13 anthocyanin species as well as to separate and identify isomeric compounds. A total of 41 metabolites (amino acids, carbohydrates, anthocyanins) were identified with all three approaches. Mass accuracy for all MS measurements was better than 2 ppm (root mean square error). The combined approach provides fast screening capabilities, spatial distribution information and the possibility to quantify metabolites. Accurate mass measurements proved to be critical in order to reliably combine data from different MS

  11. Recent advances in matrix-assisted laser desorption/ionisation mass spectrometry imaging (MALDI-MSI) for in situ analysis of endogenous molecules in plants.

    Science.gov (United States)

    Qin, Liang; Zhang, Yawen; Liu, Yaqin; He, Huixin; Han, Manman; Li, Yanyan; Zeng, Maomao; Wang, Xiaodong

    2018-04-17

    Mass spectrometry imaging (MSI) as a label-free and powerful imaging technique enables in situ evaluation of a tissue metabolome and/or proteome, becoming increasingly popular in the detection of plant endogenous molecules. The characterization of structure and spatial information of endogenous molecules in plants are both very important aspects to better understand the physiological mechanism of plant organism. Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a commonly-used tissue imaging technique, which requires matrix to assist in situ detection of a variety of molecules on the surface of a tissue section. In previous studies, MALDI-MSI was mostly used for the detection of molecules from animal tissue sections, compared to plant samples due to cell structural limitations, such as plant cuticles, epicuticular waxes, and cell walls. Despite the enormous progress that has been made in tissue imaging, there is still a challenge for MALDI-MSI suitable for the imaging of endogenous compounds in plants. This review summarises the recent advances in MALDI-MSI, focusing on the application of in situ detection of endogenous molecules in different plant organs, i.e. root, stem, leaf, flower, fruit, and seed. Further improvements on instrumentation sensitivity, matrix selection, image processing and sample preparation will expand the application of MALDI-MSI in plant research. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Application of matrix-assisted laser desorption/ionization mass spectrometry imaging in combination with LC-MS in pharmacokinetic study of metformin

    Czech Academy of Sciences Publication Activity Database

    Strnad, Štěpán; Vrkoslav, Vladimír; Klimšová, Z.; Zemenová, J.; Cvačka, Josef; Maletínská, Lenka; Sýkora, D.

    2018-01-01

    Roč. 10, č. 2 (2018), s. 71-81 ISSN 1757-6180 Institutional support: RVO:61388963 Keywords : dried blood spots * mass spectrometry imaging * metformin Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.673, year: 2016

  13. Imaging with Mass Spectrometry: A SIMS and VUV-Photoionization Study of Ion-Sputtered Atoms and Clusters from GaAs and Au

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Lynelle; Zhou, Jia; Wilson, Kevin R.; Leone, Stephen R.; Ahmed, Musahid

    2008-12-05

    A new mass spectrometry surface imaging method is presented in which ion-sputtered neutrals are postionized by wavelength-tunable vacuum ultraviolet (VUV) light from a synchrotron source. Mass spectra and signal counts of the photoionized neutrals from GaAs (100) and Au are compared to those of the secondary ions. While clusters larger than dimers are more efficiently detected as secondary ions, certain species, such as As2, Au and Au2, are more efficiently detected through the neutral channel. Continuously tuning the photon wavelength allows photoionization efficiency (PIE) curves to be obtained for sputtered Asm (m=1,2) and Aun (n=1-4). From the observed ionization thresholds, sputtered neutral As and Au show no clear evidence of electronic excitation, while neutral clusters have photoionization onsets shifted to lower energies by ~;;0.3 eV. These shifts are attributed to unresolved vibrational and rotational excitations. High-spatial resolution chemical imaging with synchrotron VUV postionization is demonstrated at two different photon energies using a copper TEM grid embedded in indium. The resulting images are used to illustrate the use of tunable VUV light for verifying mass peak assignments by exploiting the unique wavelength-dependent PIE of each sputtered neutral species. This capability is valuable for identifying compounds when imaging chemically complex systems with mass spectrometry-based techniques.

  14. Mass spectrometry imaging of illicit drugs in latent fingerprints by matrix-free and matrix-assisted desorption/ionization techniques.

    Czech Academy of Sciences Publication Activity Database

    Škríba, Anton; Havlíček, Vladimír

    2018-01-01

    Roč. 24, č. 1 (2018), s. 124-128 ISSN 1469-0667 R&D Projects: GA MŠk(CZ) LO1509; GA ČR(CZ) GA16-20229S Institutional support: RVO:61388971 Keywords : MALDI * Mass spectrometry imaging * NALDI Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 1.022, year: 2016

  15. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation.

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi 3 + beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm 2 . The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  16. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi3+ beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm2. The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  17. Imaging spectroscopy to assess the composition of ice surface materials and their impact on glacier mass balance

    Science.gov (United States)

    Naegeli, Kathrin; Huss, Matthias; Damm, Alexander; de Jong, Rogier; Schaepman, Michael; Hoelzle, Martin

    2014-05-01

    The ice-albedo feedback plays a crucial role in various glaciological processes, but especially influences ice melt. Glacier surface albedo is one of the most important variables in the energy balance of snow and ice, but depends in a complicated way on many factors, such as cryoconite concentration, impurities due to mineral dust, soot or organic matter, grain size or ice surface morphology. Our understanding on how these various factors influence glacier albedo is still limited hindering a spatially and temporally explicit parameterization of energy balance models and requiring strongly simplified assumptions on actual albedo values. Over the last two decades, several studies have focused on glacier surface albedo using automatic in-situ weather stations in combination with radiation measurement setups or satellite images. Due to limitations of both approaches in matching either the spatial or the temporal length scale of glacier albedo, still fairly little is known about the state, changes and impact of glacier surface albedo in the Swiss Alps, although there are obvious changes in surface characteristics on most alpine glaciers over the last years. With use of the APEX (Airborne Prism EXperiment) image spectrometer, measurements of reflected radiation were acquired in high spatial and spectral resolution on Glacier de la Plaine Morte, Switzerland, to explicitly analyse the ice surface. In-situ radiometric measurements were acquired with an ASD field spectrometer in parallel to APEX overflights. These data are intended to be used for validation purposes as well as input data for the linear spectral unmixing analysis of the APEX data. Seasonal glacier mass balance is monitored since five years using the direct glaciological method. This contribution presents a first evaluation of the data collected in summer 2013. The obtained in-situ and airborne reflectance measurements were used in combination with a spectral mixture analysis (SMA) approach to assess the

  18. Mass Spectrometry Imaging of low Molecular Weight Compounds in Garlic (Allium sativum L.) with Gold Nanoparticle Enhanced Target.

    Science.gov (United States)

    Misiorek, Maria; Sekuła, Justyna; Ruman, Tomasz

    2017-11-01

    Garlic (Allium sativum) is the subject of many studies due to its numerous beneficial properties. Although compounds of garlic have been studied by various analytical methods, their tissue distributions are still unclear. Mass spectrometry imaging (MSI) appears to be a very powerful tool for the identification of the localisation of compounds within a garlic clove. Visualisation of the spatial distribution of garlic low-molecular weight compounds with nanoparticle-based MSI. Compounds occurring on the cross-section of sprouted garlic has been transferred to gold-nanoparticle enhanced target (AuNPET) by imprinting. The imprint was then subjected to MSI analysis. The results suggest that low molecular weight compounds, such as amino acids, dipeptides, fatty acids, organosulphur and organoselenium compounds are distributed within the garlic clove in a characteristic manner. It can be connected with their biological functions and metabolic properties in the plant. New methodology for the visualisation of low molecular weight compounds allowed a correlation to be made between their spatial distribution within a sprouted garlic clove and their biological function. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Automation and Control of an Imaging Internal Laser Desorption Fourier Transform Mass Spectrometer (I2LD-FTMS)

    Energy Technology Data Exchange (ETDEWEB)

    McJunkin, Timothy R; Tranter, Troy Joseph; Scott, Jill Rennee

    2002-06-01

    This paper describes the automation of an imaging internal source laser desorption Fourier transform mass spectrometer (I2LD-FTMS). The I2LD-FTMS consists of a laser-scanning device [Scott and Tremblay, Rev. Sci. Instrum. 2002, 73, 1108–1116] that has been integrated with a laboratory-built FTMS using a commercial data acquisition system (ThermoFinnigan FT/MS, Bremen, Germany). A new user interface has been developed in National Instrument's (Austin, Texas) graphical programming language LabVIEW to control the motors of the laser positioning system and the commercial FTMS data acquisition system. A feature of the FTMS software that allows the user to write macros in a scripting language is used creatively to our advantage in creating a mechanism to control the FTMS from outside its graphical user interface. The new user interface also allows the user to configure target locations. Automation of the data analysis along with data display using commercial graphing software is also described.

  20. Imaging mass spectrometry reveals fiber-specific distribution of acetylcarnitine and contraction-induced carnitine dynamics in rat skeletal muscles.

    Science.gov (United States)

    Furuichi, Yasuro; Goto-Inoue, Naoko; Manabe, Yasuko; Setou, Mitsutoshi; Masuda, Kazumi; Fujii, Nobuharu L

    2014-10-01

    Carnitine is well recognized as a key regulator of long-chain fatty acyl group translocation into the mitochondria. In addition, carnitine, as acetylcarnitine, acts as an acceptor of excess acetyl-CoA, a potent inhibitor of pyruvate dehydrogenase. Here, we provide a new methodology for accurate quantification of acetylcarnitine content and determination of its localization in skeletal muscles. We used matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) to visualize acetylcarnitine distribution in rat skeletal muscles. MALDI-IMS and immunohistochemistry of serial cross-sections showed that acetylcarnitine was enriched in the slow-type muscle fibers. The concentration of ATP was lower in muscle regions with abundant acetylcarnitine, suggesting a relationship between acetylcarnitine and metabolic activity. Using our novel method, we detected an increase in acetylcarnitine content after muscle contraction. Importantly, this increase was not detected using traditional biochemical assays of homogenized muscles. We also demonstrated that acetylation of carnitine during muscle contraction was concomitant with glycogen depletion. Our m