WorldWideScience

Sample records for multi-channel mass risk

  1. Masses and widths of scalar–isoscalar multi-channel resonances from data analysis

    International Nuclear Information System (INIS)

    Surovtsev, Yurii S; Bydžovský, Petr; Kamiński, Robert; Lyubovitskij, Valery E; Nagy, Miroslav

    2014-01-01

    The peculiarities of obtaining parameters for broad multi-channel resonances from data are discussed, analyzing the experimental data on processes ππ→ππ,K K-bar in the I G J PC = 0 + 0 ++ channel in a model-independent approach based on analyticity and unitarity, and using an uniformization procedure. We show that it is possible to obtain a good description of the ππ scattering data from the threshold to 1.89 GeV with parameters of resonances cited in the Particle Data Group tables as preferred. However, in this case, first, the representation of the ππ background is unsatisfactory; second, the data on the coupled process ππ→K K-bar are not well described even qualitatively above 1.15 GeV when using the resonance parameters from only the ππ scattering analysis. The combined analysis of these coupled processes is needed, and is carried out satisfactorily. Then, both of the above-indicated issues related to the analysis of ππ scattering only are overcome. The most remarkable change of parameters with respect to the values of the ππ scattering only analysis appears for the mass of the f 0 (600), which is now in some accordance with the Weinberg prediction on the basis of mended symmetry and with an analysis using the large-N c consistency conditions between the unitarization and resonance saturation. The obtained ππ scattering length a 0 0 , in the case where we are restricted to the analysis of the ππ scattering or where we consider the so-called A-solution (with a lower mass and width of f 0 (600) meson), agrees well with the prediction of the chiral perturbation theory and with data extracted at CERN by the NA48/2 collaboration from the analysis of the K e4 decay and by the DIRAC collaboration from the measurement of the π + π − lifetime. (paper)

  2. Multi-channel Kondo necklace

    International Nuclear Information System (INIS)

    Fazekas, P.; Kee Haeyoung.

    1993-06-01

    A multi-channel generalization of Doniach's Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins τ J , j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig

  3. Multi-channel Kondo necklace

    Energy Technology Data Exchange (ETDEWEB)

    Fazekas, P; Haeyoung, Kee

    1993-06-01

    A multi-channel generalization of Doniach`s Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins {tau}{sub J}, j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig.

  4. Digital Multi Channel Analyzer Enhancement

    International Nuclear Information System (INIS)

    Gonen, E.; Marcus, E.; Wengrowicz, U.; Beck, A.; Nir, J.; Sheinfeld, M.; Broide, A.; Tirosh, D.

    2002-01-01

    A cement analyzing system based on radiation spectroscopy had been developed [1], using novel digital approach for real-time, high-throughput and low-cost Multi Channel Analyzer. The performance of the developed system had a severe problem: the resulted spectrum suffered from lack of smoothness, it was very noisy and full of spikes and surges, therefore it was impossible to use this spectrum for analyzing the cement substance. This paper describes the work carried out to improve the system performance

  5. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  6. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  7. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We

  8. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  9. A low power Multi-Channel Analyzer

    International Nuclear Information System (INIS)

    Anderson, G.A.; Brackenbush, L.W.

    1993-06-01

    The instrumentation used in nuclear spectroscopy is generally large, is not portable, and requires a lot of power. Key components of these counting systems are the computer and the Multi-Channel Analyzer (MCA). To assist in performing measurements requiring portable systems, a small, very low power MCA has been developed at Pacific Northwest Laboratory (PNL). This MCA is interfaced with a Hewlett Packard palm top computer for portable applications. The MCA can also be connected to an IBM/PC for data storage and analysis. In addition, a real-time time display mode allows the user to view the spectra as they are collected

  10. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  11. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    In this paper, a method for multi-channel pitch estimation is proposed. The method is a maximum likelihood estimator and is based on a parametric model where the signals in the various channels share the same fundamental frequency but can have different amplitudes, phases, and noise characteristics....... This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  12. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping; Wu, Ying; Lai, Yun

    2016-01-01

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  13. Skyrmion-based multi-channel racetrack

    Science.gov (United States)

    Song, Chengkun; Jin, Chendong; Wang, Jinshuai; Xia, Haiyan; Wang, Jianbo; Liu, Qingfang

    2017-11-01

    Magnetic skyrmions are promising for the application of racetrack memories, logic gates, and other nano-devices, owing to their topologically protected stability, small size, and low driving current. In this work, we propose a skyrmion-based multi-channel racetrack memory where the skyrmion moves in the selected channel by applying voltage-controlled magnetic anisotropy gates. It is demonstrated numerically that a current-dependent skyrmion Hall effect can be restrained by the additional potential of the voltage-controlled region, and the skyrmion velocity and moving channel in the racetrack can be operated by tuning the voltage-controlled magnetic anisotropy, gate position, and current density. Our results offer a potential application of racetrack memory based on skyrmions.

  14. New ultra small battery operated portable multi-channel analyzer

    International Nuclear Information System (INIS)

    Wolf, M.A.; Umbarger, C.J.

    1979-01-01

    A newly designed portable multi-channel analyzer (MCA) has been developd at Los Alamos that has much improved physical and performance characteristics over previous designs. Namely, the instrument is very compact (25 cm wide x 14 cm deep x 21 cm high) and has a mass of 4.2 Kg (9.2 lb). The device has 1024 channels and is microprocessor controlled. The instrument has most of the standard features of present laboratory-based pulse height analyzers, including CRT display, region of interest integration, etc. Battery life of the MCA is nearly eight hours, with full charging over night. An accessory case carries a small audio cassette recorder for data storage. The case also contains two different NaI(Tl) detectors

  15. Multi-channel data acquisition system for CT

    International Nuclear Information System (INIS)

    Cao Fuqiang; He Bin; Liu Guohua; Xu Minjian

    2009-01-01

    The architecture design and realization of a data acquisition system for multi-channel CT is described. The article introduces the conversion of analog signal to digital signal, the data cache and transmission. This data acquisition system can be widely used in the system which requires the multi-channel, weak current signal detection. (authors)

  16. Computer-based multi-channel analyzer based on internet

    International Nuclear Information System (INIS)

    Zhou Xinzhi; Ning Jiaoxian

    2001-01-01

    Combined the technology of Internet with computer-based multi-channel analyzer, a new kind of computer-based multi-channel analyzer system which is based on browser is presented. Its framework and principle as well as its implementation are discussed

  17. Multi-channel mechanical test machine for HANARO (I)

    International Nuclear Information System (INIS)

    Song, M. S.; Choi, Y.; Cho, M. S.; Kim, B. G.; Kang, Y. H.

    2004-01-01

    Design and fabrication of multi-channel mechanical test machine is useful and important for the study of in-pile test of nuclear materials in HANARO. The dimension and shape of the multi-channel mechanical test machine should be fixed to a test reactor and their objectives. KAERI successfully developed a non-instrumented multi-channel mechanical test machine for material irradiation tests in a domestic research reactor, HANARO. This results in strongly stimulating and accelerating irradiation tests of materials in domestic industry and research fields with HANARO. Although various types of in-pile creep capsule were made for well installation in each test reactor, there is no in-pile creep multi-channel mechanical test machine for HANARO. Hence, the objectives of this study are to fabricate and test a multi-channel mechanical test machine of HANARO

  18. Multi-Channel Capacitive Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Bingnan Wang

    2016-01-01

    Full Text Available In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved.

  19. Multi-channel phase-equivalent transformation and supersymmetry

    OpenAIRE

    Shirokov, A. M.; Sidorenko, V. N.

    2000-01-01

    Phase-equivalent transformation of local interaction is generalized to the multi-channel case. Generally, the transformation does not change the number of the bound states in the system and their energies. However, with a special choice of the parameters, the transformation removes one of the bound states and is equivalent to the multi-channel supersymmetry transformation recently suggested by Sparenberg and Baye. Using the transformation, it is also possible to add a bound state to the discr...

  20. Essays on Online and Multi-Channel Marketing

    OpenAIRE

    Zhang, Lingling

    2016-01-01

    Firms increasingly adopt online and multi-channel marketing strategies to reach and persuade consumers. Therefore, designing an effective marketing mix is critical to their success. The aim of my dissertation is to understand the strategy behind firms’ channel choices and assess marketing effectiveness. It consists of three large-scale empirical studies examining several important aspects of online and multi-channel marketing. My first essay focuses on the business-to-business (B2B) inte...

  1. The Buywell Way: seven essential practices of a highly successful multi-channel e-tailer

    Directory of Open Access Journals (Sweden)

    Mary Tate

    2005-05-01

    Full Text Available After the dot-com bust there is considerable evidence that multi-channel retailers are more successful than purely on-line retailers. Multi-channel retailing is becoming mainstream and considerable research exists on successful multi-channel strategies. Despite this, some organisations are having more success than others with their multi-channel approach. We talked to the management of one of Australasia’s most successful multi-channel apparel and home-ware retailers about the theory and practice of multi-channel retailing, with the aim of building on existing theory in multi-channel e-commerce.

  2. A multi-channel stakeholder consultation process for transmission deregulation

    International Nuclear Information System (INIS)

    Gregory, Robin; Fischhoff, Baruch; Thorne, Sarah; Butte, Gordon

    2003-01-01

    Deregulating Ontario's energy market required designing a rate structure for transmission costs that previously had been bundled with other electricity services. The Ontario Hydro Networks Company (now called Hydro One Networks, or 'Hydro One') owns and operates the transmission lines. It sought input from a full spectrum of stakeholders in preparing a proposed rate structure for submission to the regulator, the Ontario Energy Board (OEB). Securing that input meant accommodating great differences in stakeholders' familiarity with the (often highly technical) issues of rate setting. Hydro One drew on recent developments in stakeholder processes, integrated assessment, and risk communication to create a multi-channel process for eliciting and responding to stakeholder input. That process included (a) detailed background documents, (b) dedicated briefings and workshops, (c) mental models interviews, (d) focused meetings, and (e) mail (and email) boxes. The process was coordinated with a formal expert model, summarizing the factors determining the multiple impacts of the rate structure and the regulatory process producing it. The model analyzed these impacts, structured communications, and organized inputs, in a comprehensive and coherent way. This process facilitated developing proposals that were both technically sound and widely accepted by stakeholders, including the OEB. The case study provides a model for addressing other problems requiring stakeholder input on complex technical issues. It contrasts with other consultative processes with a less formal structure for eliciting concerns, less ability to encourage learning, and greater emphasis on achieving consensus

  3. Robust, highly customizable, and economical multi-channel electrode for chronic multi-unit recording in behaving animals.

    Science.gov (United States)

    Tateyama, Yukina; Oyama, Kei; Shiraishi, Masaru; Iijima, Toshio; Tsutsui, Ken-Ichiro

    2017-12-01

    Multi-unit recording has been one of the most widely used techniques to investigate the correlation between multiple neuronal activities and behavior. However, a common problem of currently used multi-channel electrodes is their physical weakness. In this study, we developed a novel multi-channel electrode with sufficient physical strength to penetrate a thickened dura mater. This electrode consists of low-cost materials and is easily fabricated, and it enables recording without removing dura mater, thereby reducing the risk of inflammation, infection, or brain herniation. The low-cost multi-channel electrode developed in this study would be a useful tool for chronic recording in behaving animals. Copyright © 2017. Published by Elsevier B.V.

  4. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  5. Multi-channel electronically scanned cryogenic pressure sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Kruse, Nancy M. H. (Inventor)

    1995-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  6. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630

  7. A high-speed interface for multi-channel analyzer

    International Nuclear Information System (INIS)

    Shen Ji; Zheng Zhong; Qiao Chong; Chen Ziyu; Ye Yunxiu; Ye Zhenyu

    2003-01-01

    This paper presents a high-speed computer interface for multi-channel analyzer based on DMA technique. Its essential principle and operating procedure are introduced. By the detecting of γ spectrum of 137 Cs with the interface, it's proved that the interface can meet the requirements of high-speed data acquisition

  8. Dense Clustered Multi-Channel Wireless Sensor Cloud

    Directory of Open Access Journals (Sweden)

    Sivaramakrishnan Sivakumar

    2015-08-01

    Full Text Available Dense Wireless Sensor Network Clouds have an inherent issue of latency and packet drops with regards to data collection. Though there is extensive literature that tries to address these issues through either scheduling, channel contention or a combination of the two, the problem still largely exists. In this paper, a Clustered Multi-Channel Scheduling Protocol (CMSP is designed that creates a Voronoi partition of a dense network. Each partition is assigned a channel, and a scheduling scheme is adopted to collect data within the Voronoi partitions. This scheme collects data from the partitions concurrently and then passes it to the base station. CMSP is compared using simulation with other multi-channel protocols like Tree-based Multi-Channel, Multi-Channel MAC and Multi-frequency Media Access Control for wireless sensor networks. Results indicate CMSP has higher throughput and data delivery ratio at a lower power consumption due to network partitioning and hierarchical scheduling that minimizes load on the network.

  9. Salt Intrusion, Tides and Mixing in Multi-channel Estuaries

    NARCIS (Netherlands)

    Nguyen, A.D.

    2008-01-01

    Multi-channel estuaries, such as the Mekong Delta in Vietnam and the Scheldt in the Netherlands, have characteristics of both the river and the sea, forming a unique environment influenced by tidal movements of the sea and freshwater flow of the river. This study addresses a number of knowledge gaps

  10. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  11. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  12. The Art of Multi-channel Hypermedia Application Development

    NARCIS (Netherlands)

    Synodinos, Dionysios G.; Avgeriou, Paris

    2003-01-01

    The plethora of networked devices and platforms that continuously come to light, as well as the emergence of alternative ways to access the internet, have increased the demand for multi-channel access to hypermedia applications. Researchers and practitioners nowadays not only have to deal with the

  13. Recent advances in Multi-Channel Algebraic Scattering

    International Nuclear Information System (INIS)

    Karataglidis, S.; Fraser, P. R.; Amos, K.; Canton, L.; Pisent, G.; Svenne, J. P.; Knijff, D. van der

    2011-01-01

    For coupled-channel descriptions of low-energy nucleon-induced interactions involving nuclei with particle-unstable exited states, it is necessary to include the widths of the target states. How those widths may affect the elastic scattering cross sections is examined within the framework of the Multi-Channel Algebraic Scattering (MCAS) method.

  14. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies

  15. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin; Zhang Qi; Zheng Futang

    2000-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images are presented. The software for object separating, mass calculating, 3D positioning, speed determining and cavity reconstruction are described

  16. Pre-experiment testing of the Multi Channel Systems 16-channel preamplifier CPA16

    International Nuclear Information System (INIS)

    Patin, J B; Stoyer, M A; Moody, K J; Friensehner, A V

    2003-01-01

    The 16-channel preamplifier model CPA16 from Multi Channel Systems was studied. The CPA16 preamplifier/amplifier module is a candidate to be used as the preamplifiers and amplifiers for the focal plane detectors of the Mass Analyzer of Super Heavy Atoms (MASHA). The equipment used to test the CPA16, the results of testing the CPA16 with a pulser, a mixed 229 Th/ 148 Gd source and a 252 Cf source, and a summary of the results will be presented

  17. On-line gas mixing and multi-channel distribution system

    International Nuclear Information System (INIS)

    Kalmani, S.D.; Mondal, N.K.; Satyanarayana, B.; Verma, P.; Joshi, Avinash

    2009-01-01

    In this presentation, we describe a mass-flow controller based on-line gas mixing unit with the multi-channel distribution system. We highlight different aspects such as requirement, design, calibration, control and operation of this system. This unit has the capability to mix up to four different input gases and distribute over 16 output channels. Output in individual channels is controlled accurately by using capillary-based system. At present, we are using this gas mixing unit for prototype of iron calorimeter (ICAL) detector of India-based Neutrino Observatory (INO).

  18. Analysis of flow distribution instability in parallel thin rectangular multi-channel system

    Energy Technology Data Exchange (ETDEWEB)

    Xia, G.L. [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China); Su, G.H., E-mail: ghsu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Peng, M.J. [Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China)

    2016-08-15

    Highlights: • Flow distribution instability in parallel thin rectangular multi-channel system is studied using RELAP5 codes. • Flow excursion may bring parallel heating channel into the density wave oscillations region. • Flow distribution instability is more likely to happen at low power/flow ratio conditions. • The increase of channel number will not affect the flow distribution instability boundary. • Asymmetry inlet throttling and heating will make system more unstable. - Abstract: The flow distribution instability in parallel thin rectangular multi-channel system has been researched in the present study. The research model of parallel channel system is established by using RELAP5/MOD3.4 codes. The transient process of flow distribution instability is studied at imposed inlet mass flow rate and imposed pressure drop conditions. The influence of heating power, mass flow rate, system pressure and channel number on flow distribution instability are analyzed. Furthermore, the flow distribution instability of parallel two-channel system under asymmetric inlet throttling and heating power is studied. The results show that, if multi-channel system operates at the negative slope region of channel ΔP–G curve, small disturbance in pressure drop will lead to flow redistribution between parallel channels. Flow excursion may bring the operating point of heating channel into the density-wave oscillations region, this will result in out-phase or in-phase flow oscillations. Flow distribution instability is more likely to happen at low power/flow ratio conditions, the stability of parallel channel system increases with system pressure, the channel number has a little effect on system stability, but the asymmetry inlet throttling or heating power will make the system more unstable.

  19. Multi-channel temperature measurement system for automotive battery stack

    Science.gov (United States)

    Lewczuk, Radoslaw; Wojtkowski, Wojciech

    2017-08-01

    A multi-channel temperature measurement system for monitoring of automotive battery stack is presented in the paper. The presented system is a complete battery temperature measuring system for hybrid / electric vehicles that incorporates multi-channel temperature measurements with digital temperature sensors communicating through 1-Wire buses, individual 1-Wire bus for each sensor for parallel computing (parallel measurements instead of sequential), FPGA device which collects data from sensors and translates it for CAN bus frames. CAN bus is incorporated for communication with car Battery Management System and uses additional CAN bus controller which communicates with FPGA device through SPI bus. The described system can parallel measure up to 12 temperatures but can be easily extended in the future in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.

  20. Multi-channel fiber optic dew and humidity sensor

    Science.gov (United States)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  1. Mimicking multi-channel scattering with single-channel approaches

    OpenAIRE

    Grishkevich, Sergey; Schneider, Philipp-Immanuel; Vanne, Yulian V.; Saenz, Alejandro

    2009-01-01

    The collision of two atoms is an intrinsic multi-channel (MC) problem as becomes especially obvious in the presence of Feshbach resonances. Due to its complexity, however, single-channel (SC) approximations, which reproduce the long-range behavior of the open channel, are often applied in calculations. In this work the complete MC problem is solved numerically for the magnetic Feshbach resonances (MFRs) in collisions between generic ultracold 6Li and 87Rb atoms in the ground state and in the ...

  2. Multi-channel imaging cytometry with a single detector

    Science.gov (United States)

    Locknar, Sarah; Barton, John; Entwistle, Mark; Carver, Gary; Johnson, Robert

    2018-02-01

    Multi-channel microscopy and multi-channel flow cytometry generate high bit data streams. Multiple channels (both spectral and spatial) are important in diagnosing diseased tissue and identifying individual cells. Omega Optical has developed techniques for mapping multiple channels into the time domain for detection by a single high gain, high bandwidth detector. This approach is based on pulsed laser excitation and a serial array of optical fibers coated with spectral reflectors such that up to 15 wavelength bins are sequentially detected by a single-element detector within 2.5 μs. Our multichannel microscopy system uses firmware running on dedicated DSP and FPGA chips to synchronize the laser, scanning mirrors, and sampling clock. The signals are digitized by an NI board into 14 bits at 60MHz - allowing for 232 by 174 pixel fields in up to 15 channels with 10x over sampling. Our multi-channel imaging cytometry design adds channels for forward scattering and back scattering to the fluorescence spectral channels. All channels are detected within the 2.5 μs - which is compatible with fast cytometry. Going forward, we plan to digitize at 16 bits with an A-toD chip attached to a custom board. Processing these digital signals in custom firmware would allow an on-board graphics processing unit to display imaging flow cytometry data over configurable scanning line lengths. The scatter channels can be used to trigger data buffering when a cell is present in the beam. This approach enables a low cost mechanically robust imaging cytometer.

  3. Coordinating Multi-Channel Pricing of Seasonal Goods

    OpenAIRE

    Preetam Basu

    2012-01-01

    Advancement in information technology has opened new avenues for traditional retailers to expand their operations. Pricing, which has been a critical issue, is more important than ever before as traditional retailers pursue multi-channel sales. In this paper the author studies the pricing problem of a retailer selling a seasonal product simultaneously in a ‘brick and mortar’ store as well as online. Optimal prices are derived and different product-market conditions are determined under wh...

  4. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Muller, F; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The implementation of the signal generator is presented as well as an application where it was successfully utilized.

  5. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Müller, F; The ATLAS collaboration; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The signal generator was successfully used as independent test bed for the ATLAS Level-1 Trigger Pre-Processor, providing up to 16 analogue signals.

  6. Empirical Study on Multi-Channel Service Quality and Customer Loyalty of Retailers

    OpenAIRE

    Qi Yong-zhi

    2014-01-01

    This paper studies the influence of offline RSSQ (retailing store service quality), online store ESQ (E-service quality) and O2O MCISQ (multi-channel integration service quality) on traditional retailers' customer loyalty as well as the relation of them three in multi-channel retailing. 380 customers with both offline and online shopping experience at the same retailer's store are investigated. Through the structural equation model, we find out that in multi-channel retailing, RSSQ and MCISQ ...

  7. Multi-channel grouping techniques for conducting reactor safety studies

    International Nuclear Information System (INIS)

    Waltar, A.E.; Wilburn, N.P.

    1975-01-01

    In conducting safety studies for postulated unprotected accidents in an LMFBR system, it is common practice to employ multi-channel coupled neutronics, thermal hydraulics computer programs such as SAS3A or MELT-III. The multichannel feature of such code systems is important if the natural fuel failure incoherencies and the resulting sodium void/fuel motion reactivity feedbacks--which have strong spatial variations--are to be properly modeled. Because of the large amounts of computer time associated with many channel runs, however, there is a strong incentive to conduct parametric studies with as few channels as possible. The paper presented is focused on methods successfully employed to accomplish this end for a study of the hypothetical unprotected transient overpower accident conducted for the FFTF

  8. Multi-channel bolometer system on JFT-2M tokamak

    International Nuclear Information System (INIS)

    Tamai, Hiroshi; Maeno, Masaki; Matsuda, Toshiaki; Matoba, Tohru

    1988-07-01

    Multi-channel bolometer system is designed and installed to observe the radiation profile on JFT-2M tokamak. Sensor head is made of Thinistor, which is a kind of semiconductor, because it has the advantage of higher sensitivity of about one order of magnitude than the conventional metal foil bolometer and is suitable for the profile measurement in which the signal from the plasma is relatively small. The response and cooling characteristics of the bolometer sensor are suitable for the condition of JFT-2M tokamak plasma. Low noise circuit of bridge and differentiator is developed to optimize the signal to noise ratio in the JFT-2M operating condition. With use of the bolometer system, the radiation profile in joule heating plasma as well as additional heating plasma especially in H-mode plasma is successfully observed. (author)

  9. Multi-channel unidirectional transmission of phononic crystal heterojunctions

    Science.gov (United States)

    Xu, Zhenlong; Tong, Jie; Wu, Fugen

    2018-02-01

    Two square steel columns are arranged in air to form two-dimensional square lattice phononic crystals (PNCs). Two PNCs can be combined into a non-orthogonal 45∘ heterojunction when the difference in the directional band gaps of the two PNC types is utilized. The finite element method is used to calculate the acoustic band structure, the heterogeneous junction transmission characteristics, acoustic field distribution, and many others. Results show that a non-orthogonal PNC heterojunction can produce a multi-channel unidirectional transmission of acoustic waves. With the square scatterer rotated, the heterojunction can select a frequency band for unidirectional transmission performance. This capability is particularly useful for constructing acoustic diodes with wide-bands and high-efficiency unidirectional transmission characteristics.

  10. Miniaturized multi channel infrared optical gas sensor system

    Science.gov (United States)

    Wöllenstein, Jürgen; Eberhardt, Andre; Rademacher, Sven; Schmitt, Katrin

    2011-06-01

    Infrared spectroscopy uses the characteristic absorption of the molecules in the mid infrared and allows the determination of the gases and their concentration. Especially by the absorption at longer wavelengths between 8 μm and 12 μm, the so called "fingerprint" region, the molecules can be measured with highest selectivity. We present an infrared optical filter photometer for the analytical determination of trace gases in the air. The challenge in developing the filter photometer was the construction of a multi-channel system using a novel filter wheel concept - which acts as a chopper too- in order to measure simultaneously four gases: carbon monoxide, carbon dioxide, methane and ammonia. The system consists of a broadband infrared emitter, a long path cell with 1.7m optical path length, a filter wheel and analogue and digital signal processing. Multi channel filter photometers normally need one filter and one detector per target gas. There are small detection units with one, two or more detectors with integrated filters available on the market. One filter is normally used as reference at a wavelength without any cross-sensitivities to possible interfering gases (e.g. at 3.95 μm is an "atmospheric window" - a small spectral band without absorbing gases in the atmosphere). The advantage of a filter-wheel set-up is that a single IR-detector can be used, which reduces the signal drift enormously. Pyroelectric and thermopile detectors are often integrated in these kinds of spectrometers. For both detector types a modulation of the light is required and can be done - without an additional chopper - with the filter wheel.

  11. Estimation of black carbon content for biomass burning aerosols from multi-channel Raman lidar data

    Science.gov (United States)

    Talianu, Camelia; Marmureanu, Luminita; Nicolae, Doina

    2015-04-01

    Biomass burning due to natural processes (forest fires) or anthropical activities (agriculture, thermal power stations, domestic heating) is an important source of aerosols with a high content of carbon components (black carbon and organic carbon). Multi-channel Raman lidars provide information on the spectral dependence of the backscatter and extinction coefficients, embedding information on the black carbon content. Aerosols with a high content of black carbon have large extinction coefficients and small backscatter coefficients (strong absorption), while aerosols with high content of organic carbon have large backscatter coefficients (weak absorption). This paper presents a method based on radiative calculations to estimate the black carbon content of biomass burning aerosols from 3b+2a+1d lidar signals. Data is collected at Magurele, Romania, at the cross-road of air masses coming from Ukraine, Russia and Greece, where burning events are frequent during both cold and hot seasons. Aerosols are transported in the free troposphere, generally in the 2-4 km altitude range, and reaches the lidar location after 2-3 days. Optical data are collected between 2011-2012 by a multi-channel Raman lidar and follows the quality assurance program of EARLINET. Radiative calculations are made with libRadTran, an open source radiative model developed by ESA. Validation of the retrievals is made by comparison to a co-located C-ToF Aerosol Mass Spectrometer. Keywords: Lidar, aerosols, biomass burning, radiative model, black carbon Acknowledgment: This work has been supported by grants of the Romanian National Authority for Scientific Research, Programme for Research- Space Technology and Advanced Research - STAR, project no. 39/2012 - SIAFIM, and by Romanian Partnerships in priority areas PNII implemented with MEN-UEFISCDI support, project no. 309/2014 - MOBBE

  12. Determination of optimum "multi-channel surface wave method" field parameters.

    Science.gov (United States)

    2012-12-01

    Multi-channel surface wave methods (especially the multi-channel analyses of surface wave method; MASW) are routinely used to : determine the shear-wave velocity of the subsurface to depths of 100 feet for site classification purposes. Users are awar...

  13. Multi-channel Analysis of Passive Surface Waves (MAPS)

    Science.gov (United States)

    Xia, J.; Cheng, F. Mr; Xu, Z.; Wang, L.; Shen, C.; Liu, R.; Pan, Y.; Mi, B.; Hu, Y.

    2017-12-01

    Urbanization is an inevitable trend in modernization of human society. In the end of 2013 the Chinese Central Government launched a national urbanization plan—"Three 100 Million People", which aggressively and steadily pushes forward urbanization. Based on the plan, by 2020, approximately 100 million people from rural areas will permanently settle in towns, dwelling conditions of about 100 million people in towns and villages will be improved, and about 100 million people in the central and western China will permanently settle in towns. China's urbanization process will run at the highest speed in the urbanization history of China. Environmentally friendly, non-destructive and non-invasive geophysical assessment method has played an important role in the urbanization process in China. Because human noise and electromagnetic field due to industrial life, geophysical methods already used in urban environments (gravity, magnetics, electricity, seismic) face great challenges. But humanity activity provides an effective source of passive seismic methods. Claerbout pointed out that wavefileds that are received at one point with excitation at the other point can be reconstructed by calculating the cross-correlation of noise records at two surface points. Based on this idea (cross-correlation of two noise records) and the virtual source method, we proposed Multi-channel Analysis of Passive Surface Waves (MAPS). MAPS mainly uses traffic noise recorded with a linear receiver array. Because Multi-channel Analysis of Surface Waves can produces a shear (S) wave velocity model with high resolution in shallow part of the model, MPAS combines acquisition and processing of active source and passive source data in a same flow, which does not require to distinguish them. MAPS is also of ability of real-time quality control of noise recording that is important for near-surface applications in urban environment. The numerical and real-world examples demonstrated that MAPS can be

  14. Microcontroller based multi-channel ultrasonic level monitoring system

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Singh, Inder Jeet; Chadda, V.K.

    2004-01-01

    Microcontroller based Multi-channel Ultrasonic Level Monitoring System developed by Computer Division is based on echo ranging techniques to monitor level. The transmitter directs an ultrasonic burst towards the liquid, which gets reflected from the top of the liquid surface. The time taken for ultrasound to travel from the transmitter to the top of liquid surface is measured and used to calculate the liquid level. The system provides for temperature compensation for accurate measurement as the ultrasound velocity depends on the ambient temperature. It can measure liquid level up to 5 meters. A single monitor can be used to measure level in 6 tanks. PC connectivity has been provided via RS 232 and RS 485 for remote operation and data logging of level. A GUI program developed using LABVIEW package displays level on PC monitor. The program provides for pictorial as well as numerical display for level and temperature in the front panel on the PC monitor. A user can monitor level for any or all tanks from the PC. One unit is installed at CIRUS for measuring level in Acid/ Alkali tanks and one is installed at APSARA for measuring water level in the reactor pool. (author)

  15. Dynamic multi-channel TMS with reconfigurable coil.

    Science.gov (United States)

    Jiang, Ruoli; Jansen, Ben H; Sheth, Bhavin R; Chen, Ji

    2013-05-01

    Investigations of the causal involvement of particular brain areas and interconnections in behavior require an external stimulation system with reasonable spatio-temporal resolution. Current transcranial magnetic stimulation (TMS) technology is limited to stimulating a single brain area once in a given trial. Here, we present a feasibility study for a novel TMS system based on multi-channel reconfigurable coils. With this hardware, researchers will be able to stimulate multiple brain sites in any temporal order in a trial. The system employs a wire-mesh coil, constructed using x- and y-directional wires. By varying the current direction and/or strength on each wire, we can configure the proposed mesh-wire coil into a standard loop coil and figure-eight coil of varying size. This provides maximum flexibility to the experimenter in that the location and extent of stimulation on the brain surface can be modified depending on experimental requirement. Moreover, one can dynamically and automatically modify the site(s) of stimulation several times within the span of seconds. By pre-storing various sequences of excitation patterns inside a control unit, one can explore the effect of dynamic TMS on behavior, in associative learning, and as rehabilitative therapy. Here, we present a computer simulation and bench experiments that show the feasibility of the dynamically-reconfigurable coil.

  16. A multi-channel AC power supply controller

    International Nuclear Information System (INIS)

    Su Hong; Li Xiaogang; Ma Xiaoli; Zhou Bo; Yin Weiwei

    2003-01-01

    A multi-channel ac power supply controller developed recently by authors is introduced briefly in this paper. This controller is a computer controlled multi-electronic-switch device. This controller was developed for the automatic control and monitoring system of a 220 V ac power supply system, it is a key front-end device of the automatic control and monitoring system. There is an electronic switch in each channel, the rated load power is ≤1 kW/each channel. Another function is to sample the 220 V ac output voltage so that computer can monitor the operation state of each electronic switch. Through these switches, the 220 V ac power supply is applied to some device or apparatus that need to be powered by 220 V ac power supply. In the design, a solid-state relay was employed as an electronic switch. This controller can be connected in cascade mode. There are 8 boxes at most can be connected in cascade mode. The length of control word is 8 bit, which contains addressing information and electronic switch state setting information. The sampling output of the controller is multiplexed. It is only one bit that indicates the operating state of an electronic switch. This controller has been used in an automatic control and monitoring system for 220 V ac power supply system

  17. Multi-Channel Data Recording of Marx switch closures

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Ruggles, L.E.; Ziska, G.R.

    1984-01-01

    The authors have measured the optical signals associated with switch closure on the Demon marx at Sandia National Laboratories. Using the High Speed Multi-Channel Data Recorder(HSMCDR), they have recorded the time histories of the optical signals from the thirty switches in the marx generator. All thirty switches were fiber connected to the HSMCDR. The HSMCDR consists of a high speed streak camera, and a microcomputer-based video digitizing system. Since the thirty signals are recorded on a single streak, the time sequence can be determined with great accuracy. The appearance of a given signal can be determined to within two samples of the 256 samples that make up the time streak. The authors have found that the light intensity and time history of any given switch varied over a large range from shot to shot. Thus, the ability to record the entire optical signal as a function of time for each switch on every shot is necessary if accurate timing results are required

  18. Use of trapezoidal shaping algorithm in the digital multi-channel system

    International Nuclear Information System (INIS)

    Wang Jihong; Wang Lianghou; Fang Zongliang

    2011-01-01

    It discusses one kind of digital filter technology-trapezoidal algorithm based on actual need of studying the digital multi-channel. Firstly, demonstrating the feasibility of the arithmetic with theoretical analysis; secondly, predigesting the process of the arithmetic; thirdly, simulating with MATLAB; lastly, using the arithmetic to measure data. The result of testing indicates trapezoidal shaping algorithm accords with the need of digital multi-channel shaping extraordinary. The best filter can be obtained by means of setting parameter due to superiority of digital multi-channel. (authors)

  19. Integrated multi-channel vehicle-vehicle and vehicle-roadside communications for ITS

    Science.gov (United States)

    2008-12-01

    This research describes a medium access control (MAC) protocol to Enable multi-channel operation for dedicated short-range communication (DSRC). In particular, we focus on the challenge of supporting potentially high-bandwidth commercial or infotainm...

  20. Multi-channel counter-current chromatography for high-throughput fractionation of natural products for drug discovery.

    Science.gov (United States)

    Wu, Shihua; Yang, Lu; Gao, Yuan; Liu, Xiaoyue; Liu, Feiyan

    2008-02-08

    A multi-channel counter-current chromatography (CCC) method has been designed and fabricated for the high-throughput fractionation of natural products without complications sometimes encountered with other conventional chromatographic systems, such as irreversible adsorptive constituent losses and deactivation, tailing of solute peaks and contamination. It has multiple independent CCC channels and each channel connects independent separation column(s) by parallel flow tubes, and thus the multi-channel CCC apparatus can achieve simultaneously two or more independent chromatographic processes. Furthermore, a high-throughput CCC fractionation method for natural products has been developed by a combination of a new three-channel CCC apparatus and conventional parallel chromatographic devices including pumps, sample injectors, effluent detectors and collectors, and its performance has been displayed on the fractionation of ethyl acetate extracts of three natural materials Solidago canadensis, Suillus placidus, and Trichosanthes kirilowii, which are found to be potent cytotoxic to tumor cell lines in the course of screening the antitumor candidates. By combination of biological screening programs and preparative high-performance liquid chromatography (HPLC) purification, 22.8 mg 6 beta-angeloyloxykolavenic acid and 29.4 mg 6 beta-tigloyloxykolavenic acid for S. canadensis, 25.3mg suillin for S. placidus, and 6.8 mg 23,24-dihydrocucurbitacin B for T. Kirilowii as their major cytotoxic principles were isolated from each 1000 mg crude ethyl acetate extract. Their chemical structures were characterized by electrospray ionization mass spectrometry, one- and two-dimensional nuclear magnetic resonance. The overall results indicate the multi-channel CCC is very useful for high-throughput fractionation of natural products for drug discovery in spite of the solvent balancing requirement and the lower resolution of the shorter CCC columns.

  1. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  2. JADSPE, Multi-Channel Gamma Spectra Unfolding Program

    International Nuclear Information System (INIS)

    Rikovska, J.; Stejskalova, E.

    2005-01-01

    1 - Description of program or function: JADSPE is a package of eight programs to process multi-channel gamma-ray spectra. The programs can be used to: - locate automatically spectral peaks and calculate their positions, areas, and full widths at half maximum (FWHM); - plot the spectra on a CALCOMP plotter, TEKTRONIX terminal or a line printer; - add or subtract several spectra with the possibility of adjusting either their start and end channels or the maxima of the chosen corresponding peaks. The JADSPE package comprises the following programs: - SPECTF: automatic location of peaks and calculation of their positions, areas and FWHMS. The standard deviations of peak parameters are also determined, and each evaluated region is plotted on the line printer. - SPECT1: The areas and FWHMs are calculated for peaks whose positions are known beforehand. The standard deviations of calculated parameters are also determined, and each evaluated region is plotted on the line printer. - PLOCHA: The peak net area is calculated by summing the channel contents in specified regions and by subtracting a linear background. - GRAPH: Spectrum plotting on the line printer. - PLTNEW: Spectrum plotting on CALCOMP plotter or on TEKTRONIX terminal. - SUMDIF: The channel contents of several gamma-ray spectra are added or subtracted. - SSPFP: The channel contents of several gamma-ray spectra are added with adjustment of the maxima of specified peaks. - SOUCET: The channel contents of several gamma-ray spectra are added with the adjustment of start and end channels of the spectra. 2 - Method of solution: Non-linear least-square fit. 3 - Restrictions on the complexity of the problem: The full energy peaks are approximated by a symmetrical Gaussian function and the underlying background is approximated by a first-order polynomial. A fixed spectrum length of 4096 channels is assumed. Maxima of: - number of peaks in one multiplet: 9; - number of peaks identified by the automatic search procedure

  3. Multi-channel motor evoked potential monitoring during anterior cervical discectomy and fusion

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objectives: Anterior cervical discectomy and fusion (ACDF surgery is the most common surgical procedure for the cervical spine with low complication rate. Despite the potential prognostic benefit, intraoperative neurophysiological monitoring (IONM, a method for detecting impending neurological compromise, is not routinely used in ACDF surgery. The present study aimed to identify the potential benefits of monitoring multi-channel motor evoked potentials (MEPs during ACDF surgery. Methods: We retrospectively reviewed 200 consecutive patients who received IONM with multi-channel MEPs and somatosensory evoked potentials (SSEPs. On average, 9.2 muscles per patient were evaluated under MEP monitoring. Results: The rate of MEP change during surgery in the multi-level ACDF group was significantly higher than the single-level group. Two patients from the single-level ACDF group (1.7% and four patients from the multi-level ACDF group (4.9% experienced post-operative motor deficits. Multi-channel MEPs monitoring during single and multi-level ACDF surgery demonstrated higher sensitivity, specificity, positive predictive and negative predictive value than SSEP monitoring. Conclusions: Multi-channel MEP monitoring might be beneficial for the detection of segmental injury as well as long tract injury during single- and multi-level ACDF surgery. Significance: This is first large scale study to identify the usefulness of multi-channel MEPs in monitoring ACDF surgery. Keywords: Disc disease, Somatosensory evoked potentials, Intraoperative neurophysiological monitoring, Motor evoked potentials, Anterior cervical discectomy and fusion

  4. The Time Division Multi-Channel Communication Model and the Correlative Protocol Based on Quantum Time Division Multi-Channel Communication

    International Nuclear Information System (INIS)

    Liu Xiao-Hui; Pei Chang-Xing; Nie Min

    2010-01-01

    Based on the classical time division multi-channel communication theory, we present a scheme of quantum time-division multi-channel communication (QTDMC). Moreover, the model of quantum time division switch (QTDS) and correlative protocol of QTDMC are proposed. The quantum bit error rate (QBER) is analyzed and the QBER simulation test is performed. The scheme shows that the QTDS can carry out multi-user communication through quantum channel, the QBER can also reach the reliability requirement of communication, and the protocol of QTDMC has high practicability and transplantable. The scheme of QTDS may play an important role in the establishment of quantum communication in a large scale in the future. (general)

  5. Software filtering method to suppress spike pulse interference in multi-channel scaler

    International Nuclear Information System (INIS)

    Huang Shun; Zhao Xiuliang; Li Zhiqiang; Zhao Yanhui

    2008-01-01

    In the test on anti-jamming function of a multi-channel scaler, we found that the spike pulse interference on the second level counter caused by the motor start-stop operations brings a major count error. There are resolvable characteristics between effective signal and spike pulse interference, and multi-channel hardware filtering circuit is too huge and can't filter thoroughly, therefore we designed a software filtering method. In this method based on C8051F020 MCU, we dynamically store sampling values of one channel in only a one-byte variable and distinguish the rise-trail edge of a signal and spike pulse interference because of value changes of the variable. Test showed that the filtering software method can solve the error counting problem of the multi-channel scaler caused by the motor start-stop operations. The flow chart and source codes of the method were detailed in this paper. (authors)

  6. A multi-channel isolated power supply in non-equipotential circuit

    Science.gov (United States)

    Li, Xiang; Zhao, Bo-Wen; Zhang, Yan-Chi; Xie, Da

    2018-04-01

    A multi-channel isolation power supply is designed for the problems of different MOSFET or IGBT in the non-equipotential circuit in this paper. It mainly includes the square wave generation circuit, the high-frequency transformer and the three-terminal stabilized circuit. The first part is used to generate the 24V square wave, and as the input of the magnetic ring transformer. In the second part, the magnetic ring transformer consists of one input and three outputs to realize multi-channel isolation output. The third part can output different potential and realize non-equal potential function through the three-terminal stabilized chip. In addition, the multi-channel isolation power source proposed in this paper is Small size, high reliability and low price, and it is convenient for power electronic switches that operate on multiple different potentials. Therefore, the research on power supply of power electronic circuit has practical significance.

  7. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  8. Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays

    International Nuclear Information System (INIS)

    Kong Jie; Su Hong; Chen Zhiqiang; Dong Chengfu; Qian Yi; Gao Shanshan; Zhou Chaoyang; Lu Wan; Ye Ruiping; Ma Junbing

    2010-01-01

    A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable GI controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz.

  9. A multi-channel humidity control system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhang Aiwu; Xie Yuguang; Liu Hongbang; Liu Yingbiao; Cai Xiao; Yu Boxiang; Lu Junguang; Zhou Li

    2011-01-01

    A real time multi-channel humidity control system was designed based on LabVIEW, using the dry air branch of BESⅢ drying system. The hardware of this control system consist of mini humidity and temperature sensors, intelligent collection module, switch quantity controller and electromagnetic valves. The humidity can be controlled at arbitrary value from air humidity to 3% with accuracy better than 2%. Multi microenvironment with different humidity can be easily controlled and monitored in real time by this system. It can also be extended to hybrid control of multi channel humidity and temperature. (authors)

  10. Multi-channel spintronic transistor design based on magnetoelectric barriers and spin-orbital effects

    International Nuclear Information System (INIS)

    Fujita, T; Jalil, M B A; Tan, S G

    2008-01-01

    We present a spin transistor design based on spin-orbital interactions in a two-dimensional electron gas, with magnetic barriers induced by a patterned ferromagnetic gate. The proposed device overcomes certain shortcomings of previous spin transistor designs such as long device length and degradation of conductance modulation for multi-channel transport. The robustness of our device for multi-channel transport is unique in spin transistor designs based on spin-orbit coupling. The device is more practical in fabrication and experimental respects compared to previously conceived single-mode spin transistors

  11. The design and implementation of a PC based multi-channel scaler system

    International Nuclear Information System (INIS)

    Wang Qiang; Chinese Academy of Sciences, Beijing; Jin Dapeng; Liu Zhen'an; Zhao Dixin

    2007-01-01

    A multi-channel scaler system is designed for the system check and status monitoring of the BESIII trigger system. It is composed of a PC, two PCI interface multi-channel scaler cards, the corresponding drivers and user programs. Total 64 signals can be scaled and monitored in real time. The scaled data are recorded locally and some of them are distributed to the online system. In this paper, the hardware structure, software development and long time running stability of the system are introduced. (authors)

  12. The development of 128 ch fast multi channel pulse height analyzer for a tokamak plasmas

    International Nuclear Information System (INIS)

    Kawashima, Hisato; Matoba, Tohru; Ogawa, Toshihide; Kawakami, Tomohide

    1985-02-01

    A high counting rate multi channel pulse height analyzer was developed and tested to measure the detailed time evolution of X-ray energy spectrun radiated from a tokamak plasmas. Main developing objects of this analyzer are as follows. 1. The maximum counting rate and the minimum time resolution are 4 Mcps and 10 ms, respectively. 2. The energy resolution has ability to distinguish the characterisitic X-ray line. 3. Computer has to be used for operating system. This fast multi channel analyzer is using to measure the Soft X-ray spectrum on JFT-2M tokamak, and is confirmed to be useful for a practical measuring system. (author)

  13. MULTI-CHANNEL VOLUME SPHYGMOGRAPHY IN CARDIOANGIOLOGICAL SCREENING OF THE ADULT POPULATION

    Directory of Open Access Journals (Sweden)

    R. A. Khokhlov

    2015-01-01

    Full Text Available Aim. To study the possibilities of using multi-channel volume sphygmography (MCVS in prophylactic medical examination of the population.Material and methods. Simultaneous examination of 522 individuals older than 18 years was performed. Along with standard procedures provided by the prophylactic medical examination program synchronous registration of blood pressure (BP on four extremities by MCVS was performed. At that a difference in systolic BP between arms (ΔSBParm and legs (ΔSBPleg and ankle-brachial index (ABI were automatically calculated. Values of │ΔSBParm│ or │ΔSBPleg│≥15 mm Hg or ABI≤0.9 were considered as markers of atherosclerotic vascular disease.Results. Signs of peripheral arterial atherosclerotic lesions among patients ≥40 years old were found in 14.7% of the cases (95% confidence interval [CI] 11.7-18.4. Relative risks of atherosclerotic lesions in arteries increase 1.71-fold (95% CI 1.06-2.74 in arterial hypertension, 1.70-fold (95% CI 1.08-2.68 – in obesity, 1.91 fold (95% CI 1.17-3.12 – in diabetes, as well as with the increasing levels of cardiovascular risk. In patients with ischemic heart disease and a history of cerebral stroke MCVS can detect signs of multifocal atherosclerosis in 21% (95% CI 14-32 and 22% (95% CI 9-46 of the cases, respectively.Conclusion. MCVS with the determination of ΔSBParm, ΔSBPleg and ABI may be regarded as the basis for low-cost and efficient system of cardioangiological screening.

  14. MULTI-CHANNEL VOLUME SPHYGMOGRAPHY IN CARDIOANGIOLOGICAL SCREENING OF THE ADULT POPULATION

    Directory of Open Access Journals (Sweden)

    R. A. Khokhlov

    2015-09-01

    Full Text Available Aim. To study the possibilities of using multi-channel volume sphygmography (MCVS in prophylactic medical examination of the population.Material and methods. Simultaneous examination of 522 individuals older than 18 years was performed. Along with standard procedures provided by the prophylactic medical examination program synchronous registration of blood pressure (BP on four extremities by MCVS was performed. At that a difference in systolic BP between arms (ΔSBParm and legs (ΔSBPleg and ankle-brachial index (ABI were automatically calculated. Values of │ΔSBParm│ or │ΔSBPleg│≥15 mm Hg or ABI≤0.9 were considered as markers of atherosclerotic vascular disease.Results. Signs of peripheral arterial atherosclerotic lesions among patients ≥40 years old were found in 14.7% of the cases (95% confidence interval [CI] 11.7-18.4. Relative risks of atherosclerotic lesions in arteries increase 1.71-fold (95% CI 1.06-2.74 in arterial hypertension, 1.70-fold (95% CI 1.08-2.68 – in obesity, 1.91 fold (95% CI 1.17-3.12 – in diabetes, as well as with the increasing levels of cardiovascular risk. In patients with ischemic heart disease and a history of cerebral stroke MCVS can detect signs of multifocal atherosclerosis in 21% (95% CI 14-32 and 22% (95% CI 9-46 of the cases, respectively.Conclusion. MCVS with the determination of ΔSBParm, ΔSBPleg and ABI may be regarded as the basis for low-cost and efficient system of cardioangiological screening.

  15. New-fashioned Multi-channel Analyzer Based on Bipartition Method

    International Nuclear Information System (INIS)

    Liu Mingjian; Zhang Yan; Yan Xuekun; Chen Ying

    2009-01-01

    A new-fashioned digital-analog converter (DAC) which can find the pulse-signal amplitude through dichotomy is devised. With this new DAC method, a 256-channel multi-channel pulse amplitude analyzer (MCA) is designed successfully, and its hardware and software are introduced in detail. This provides a new method for designing MCA. (authors)

  16. Personalized multi-channel headphone sound reproduction based on active noise cancellation

    NARCIS (Netherlands)

    Schobben, D.W.E.; Aarts, R.M.

    2005-01-01

    A system for headphone signal processing is discussed which gives a listener the same impression as listening to a multi-channel loudspeaker set-up. It is important that this processing is optimized for each individual listener. If this is not the case, large localization errors may occur. In the

  17. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized through- put maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  18. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2008-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized throughput maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  19. Multiple-state based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-01-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in wireless mesh networks (WMNs). In this paper, we present asynchronous multiple-state based power control for MRMC WMNs. First, WMN is represented as a set of disjoint...

  20. E-Fulfillment and Multi-Channel Distribution – A Review

    NARCIS (Netherlands)

    N.A.H. Agatz (Niels); M. Fleischmann (Moritz); J.A.E.E. van Nunen (Jo)

    2006-01-01

    textabstractThis review addresses the specific supply chain management issues of Internet fulfillment in a multi-channel environment. It provides a systematic overview of managerial planning tasks and reviews corresponding quantitative models. In this way, we aim to enhance the understanding of

  1. Exploiting the opportunities of Internet and multi-channel pricing : An exploratory research

    NARCIS (Netherlands)

    Sotgiu, Francesca; Ancarani, Fabio

    2004-01-01

    Smart firms are not worried about the impact of the Internet on pricing, but realise that they have the unique opportunity to exploit new options and improve their marketing performance. Multi-channel pricing is one of the most interesting opportunities firms can exploit in the digital economy.

  2. Range based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-08-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in Wireless Mesh Networks (WMNs). In this paper, researchers present a range based dynamic power control for MRMC WMNs. First, WMN is represented as a set of disjoint Unified...

  3. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  4. The design of multi-channel pulse amplitude analyzer based on ARM micro controller

    International Nuclear Information System (INIS)

    Li Hai; Li Xiang; Liu Caixue

    2010-01-01

    It introduces the design of multi-channel pulse amplitude analyzer based on embedded ARM micro-controller. The embedded and real-time system μC/OS-II builds up the real-time and stability of the system and advances the integration. (authors)

  5. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  6. On the relationship between multi-channel envelope and temporal fine structure

    DEFF Research Database (Denmark)

    Søndergaard, Peter Lempel; Decorsiere, Remi Julien Blaise; Dau, Torsten

    2011-01-01

    The envelope of a signal is broadly defined as the slow changes in time of the signal, where as the temporal fine structure (TFS) are the fast changes in time, i.e. the carrier wave(s) of the signal. The focus of this paper is on envelope and TFS in multi-channel systems. We discuss the differenc...

  7. A novel portable multi-channel analyzer based on high-speed microcontroller

    International Nuclear Information System (INIS)

    Lou Xinghua; Yi Hongchang; Wang Yuemin

    2005-01-01

    This paper introduces a novel portable multi-channel analyzer (MCA) based on high-speed microcontroller. The hardware implementation and the software scenario of the MCA are discussed. The MCA has features of high speed, small size and better performances. (authors)

  8. A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Networks

    Science.gov (United States)

    2001-01-01

    00-00-2001 to 00-00-2001 4. TITLE AND SUBTITLE A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Netowrks 5a. CONTRACT NUMBER...images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE

  9. An optimal multi-channel memory controller for real-time systems

    NARCIS (Netherlands)

    Gomony, M.D.; Akesson, K.B.; Goossens, K.G.W.

    2013-01-01

    Optimal utilization of a multi-channel memory, such as Wide IO DRAM, as shared memory in multi-processor platforms depends on the mapping of memory clients to the memory channels, the granularity at which the memory requests are interleaved in each channel, and the bandwidth and memory capacity

  10. Objective ARX Model Order Selection for Multi-Channel Human Operator Identification

    NARCIS (Netherlands)

    Roggenkämper, N; Pool, D.M.; Drop, F.M.; van Paassen, M.M.; Mulder, M.

    2016-01-01

    In manual control, the human operator primarily responds to visual inputs but may elect to make use of other available feedback paths such as physical motion, adopting a multi-channel control strategy. Hu- man operator identification procedures generally require a priori selection of the model

  11. A high performance multi-channel preamplifier ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Yarema, R.J.; Zimmerman, T.; Williams, W.; Binkley, M.; Huffman, T.; Wagner, R.

    1991-11-01

    A new preamplifier ASIC has been designed and built to improve performance of the VTPC (Vertex Time Projection Chamber) at Fermilab's Colliding Detector Facility. Design of the semicustom IC was completed using a Tektronix Quick-Chip 2S bipolar linear array. The ASIC has 6 channels on a chip and provides lower noise, higher gain, lower power, and lower mass packaging than the device which it replaces. Actual performance of the preamplifier was found to match very closely the simulated performance. To reduce the mass of the complete circuit board, bare IC dice were mounted directly on a G-10 substrate using COB (chip on board) techniques. The preamplifier and packaging should be applicable to numerous other systems. 1 ref.

  12. A high performance multi-channel preamplifier ASIC

    International Nuclear Information System (INIS)

    Yarema, R.J.; Zimmerman, T.; Williams, W.; Binkley, M.; Huffman, T.; Wagner, R.

    1992-01-01

    This paper reports on a new preamplifier ASIC that has been designed and built to improve performance of the VTPC (Vertex Time Projection Chamber) at Fermilab's Collliding Detector Facility. Design of the semicustom IC was completed using a Tektronix QuickChip 2S bipolar linear array. The ASIC has 6 channels on a chip and provides lower noise, higher gain, lower power, and lower mass packaging than the device which it replaces. Actual performance of the preamplifier was found to match very closely the simulated performance. To reduce the mass of the complete circuit board, bare IC dice were mounted directly on a G-10 substrate using COB (chip on board) techniques. The preamplifier and packaging should be applicable to numerous other systems

  13. A high performance multi-channel preamplifier ASIC

    International Nuclear Information System (INIS)

    Yarema, R.J.; Zimmerman, T.; Williams, W.; Binkley, M.; Huffman, T.; Wagner, R.

    1991-11-01

    A new preamplifier ASIC has been designed and built to improve performance of the VTPC (Vertex Time Projection Chamber) at Fermilab's Colliding Detector Facility. Design of the semicustom IC was completed using a Tektronix Quick-Chip 2S bipolar linear array. The ASIC has 6 channels on a chip and provides lower noise, higher gain, lower power, and lower mass packaging than the device which it replaces. Actual performance of the preamplifier was found to match very closely the simulated performance. To reduce the mass of the complete circuit board, bare IC dice were mounted directly on a G-10 substrate using COB (chip on board) techniques. The preamplifier and packaging should be applicable to numerous other systems. 1 ref

  14. High body mass index and cancer risk

    DEFF Research Database (Denmark)

    Benn, Marianne; Tybjærg-Hansen, Anne; Smith, George Davey

    2016-01-01

    of follow-up (range 0-37), 8002 developed non-skin cancer, 3347 non-melanoma skin cancer, 1396 lung cancer, 637 other smoking related cancers, 1203 colon cancer, 159 kidney cancer, 1402 breast cancer, 1062 prostate cancer, and 2804 other cancers. Participants were genotyped for five genetic variants...... with a BMI ≥ 30 versus 18.5-24.9 kg/m(2). Corresponding risk of breast cancer was 20 % (0-44 %) higher in postmenopausal women. BMI was not associated with risk of colon, kidney, other smoking related cancers, prostate cancer, or other cancers. In genetic analyses, carrying 7-10 versus 0-4 BMI increasing......High body mass index (BMI) has been associated with increased risk of some cancer. Whether these reflect causal associations is unknown. We examined this issue. Using a Mendelian randomisation approach, we studied 108,812 individuals from the general population. During a median of 4.7 years...

  15. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  16. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Science.gov (United States)

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-01-01

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction. PMID:26287193

  17. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm.

    Science.gov (United States)

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-08-13

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  18. Regret of Multi-Channel Bandit Game in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Ma Jun

    2016-01-01

    Full Text Available The problem of how to evaluate the rate of convergence to Nash equilibrium solutions in the process of channel selection under incomplete information is studied. In this paper, the definition of regret is used to reflect the convergence rates of online algorithms. The process of selecting an idle channel for each secondary user is modeled as a multi-channel bandit game. The definition of the maximal averaged regret is given. Two existing online learning algorithms are used to obtain the Nash equilibrium for each SU. The maximal averaged regrets are used to evaluate the performances of online algorithms. When there is a pure strategy Nash equilibrium in the multi-channel bandit game, the maximal averaged regrets are finite. A cooperation mechanism is also needed in the process of calculating the maximal averaged regrets. Simulation results show the maximal averaged regrets are finite and the online algorithm with greater convergence rate has less maximal averaged regrets.

  19. Multi-Channel Electronically Scanned Cryogenic Pressure Sensor And Method For Making Same

    Science.gov (United States)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Holloway, Nancy M. (Inventor)

    2001-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multi-element array. These dies are bonded at specific sites on a glass, pre-patterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  20. Asymptotically exact solution of the multi-channel resonant-level model

    International Nuclear Information System (INIS)

    Zhang Guangming; Su Zhaobin; Yu Lu.

    1994-01-01

    An asymptotically exact partition function of the multi-channel resonant-level model is obtained through Tomonaga-Luttinger bosonization. A Fermi-liquid vs. non-Fermi-liquid transition, resulting from a competition between the Kondo and X-ray edge physics, is elucidated explicitly via the renormalization group theory. In the strong-coupling limit, the model is renormalized to the Toulouse limit. (author). 20 refs, 1 fig

  1. Design of multi-channel amplitude analyzer base on LonWorks

    International Nuclear Information System (INIS)

    Zhang Ying; Zhao Lihong; Chen Aihua

    2008-01-01

    The paper introduces the multi-channel analyzer which adopts LonWorks technology. The system detects the pulse peak by hardware circuits and controls data acquisition and network communication by Micro Controller and Unit and Neuron chip. SCM is programmed by Keil C51; the communication between SCM and nerve cell is realized by Neron C language, and the computer program is written by VB language. Test results show that this analyzer is with fast conversion speed and low power consumption. (authors)

  2. An integrated analog O/E/O link for multi-channel laser neurons

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, Mitchell A., E-mail: mnahmias@princeton.edu; Tait, Alexander N.; Tolias, Leonidas; Chang, Matthew P.; Ferreira de Lima, Thomas; Shastri, Bhavin J.; Prucnal, Paul R. [Electrical Engineering Department, Princeton University, 41 Olden St, Princeton, New Jersey 08540 (United States)

    2016-04-11

    We demonstrate an analog O/E/O electronic link to allow integrated laser neurons to accept many distinguishable, high bandwidth input signals simultaneously. This device utilizes wavelength division multiplexing to achieve multi-channel fan-in, a photodetector to sum signals together, and a laser cavity to perform a nonlinear operation. Its speed outpaces accelerated-time neuromorphic electronics, and it represents a viable direction towards scalable networking approaches.

  3. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    OpenAIRE

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. ...

  4. Interference-aware power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available are well known in [9], [6]. The operation of multi-radio multi-channel (MRMC) WMNs generally requires sustainable energy supply. Substantial deployments of WMNs have recently been witnessed in rural and remote communities [4]. In such applications...]. Power resources are dynamically adjusted by each NIC using intra and inter-subsystem (channel) states. Due to the decentralized nature, each MP assumes imperfect knowledge about the global network. Further we assume that there exists...

  5. The software for the USB-based multi-channel analyzer system

    International Nuclear Information System (INIS)

    Zhou Tong; Wei Yixiang

    2002-01-01

    A new type of multi-channel analyzer system is introduced, which takes advantage of Universal Serial Bus to communicate with computer and gets the merit of fast speed, universality and Plug and Play. The authors discussed the framework of the system, primary functions, display of spectrum date and the way of communication with hardware. The environment of the program is Visual Basic 6.0

  6. Study and realization of a multi channel analyzer for a per operator probe

    International Nuclear Information System (INIS)

    Yahyaoui, Sarra; Brini, Borhen

    2006-01-01

    The goal of this project is to study and produce a Multi Channel Analyzer (MCA) prototype based on a microcontroller PIC 16F877. This prototype comprises an amplification and a peak detection parts. The microcontroller provide the analog to numeric conversion and ensures the communication with PC. This MCA will be connected to a per operator probe containing a semiconductor detector CdTe. (author). 7 refs

  7. Research on development of multi-channel analyzer used for monitoring and warning radiation equipment

    International Nuclear Information System (INIS)

    Nguyen Van Sy; Dang Quang Thieu; Nguyen Thi Bao My

    2015-01-01

    The subject assigned to this paper presents research on development of multi-channel analyzer used for monitoring and warning environmental radiation equipment under the project KC.05.16/11-15 Research on manufacturing equipment monitoring and warning radiation. In this thematic we have two subjects that need to be resolved such as: i) Designing spectroscopy amplifier block (AMP) duty pulse signals obtained about few hundred millivolts output from scintillation detector preamplifier, amplified as a few volts and the standard Gaussian pulses shaped to connect to the analog-to-digital converter. The spectroscopy amplifier block can change the gain by digital control to respond to the problem of automatic spectrum stability for multi-channel analyzer systems. ii) Designing analog-to-digital converter block (ADC) in accordance with the actual conditions, such as high stability, fast conversion time, high throughput, and it consumes low energy. Selecting suitable microprocessor for fast connection ability, to operate reliably paired with the analog-to-digital converter into a multi-channel analyzer (MCA) serving analysis. (author)

  8. Development of refined MCNPX-PARET multi-channel model for transient analysis in research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kalcheva, S.; Koonen, E. [SCK-CEN, BR2 Reactor Dept., Boeretang 200, 2400 Mol (Belgium); Olson, A. P. [RERTR Program, Nuclear Engineering Div., Argonne National Laboratory, Cass Avenue, Argonne, IL 60439 (United States)

    2012-07-01

    Reactivity insertion transients are often analyzed (RELAP, PARET) using a two-channel model, representing the hot assembly with specified power distribution and an average assembly representing the remainder of the core. For the analysis of protected by the reactor safety system transients and zero reactivity feedback coefficients this approximation proves to give adequate results. However, a more refined multi-channel model representing the various assemblies, coupled through the reactivity feedback effects to the whole reactor core is needed for the analysis of unprotected transients with excluded over power and period trips. In the present paper a detailed multi-channel PARET model has been developed which describes the reactor core in different clusters representing typical BR2 fuel assemblies. The distribution of power and reactivity feedback in each cluster of the reactor core is obtained from a best-estimate MCNPX calculation using the whole core geometry model of the BR2 reactor. The sensitivity of the reactor response to power, temperature and energy distributions is studied for protected and unprotected reactivity insertion transients, with zero and non-zero reactivity feedback coefficients. The detailed multi-channel model is compared vs. simplified fewer-channel models. The sensitivities of transient characteristics derived from the different models are tested on a few reactivity insertion transients with reactivity feedback from coolant temperature and density change. (authors)

  9. Simulation study on vertically distributed multi-channel tangential interferometry for KSTAR

    International Nuclear Information System (INIS)

    Nam, Y U; Juhn, J W

    2012-01-01

    Interferometry is powerful and reliable diagnostics which measures line-integrated electron density. Since this technique only measures an averaged value over whole probing line, a multi-channel scheme is used for an analysis for spatial distribution and variation of electron density. Typical setups of the multi-channel measurement are schemes of radially distributed vertical lines, vertically distributed horizontal lines and horizontally distributed tangential lines. In Korea Superconducting Tokamak Advanced Research, a vertically distributed multi-channel tangential interferometry is planned instead of above typical schemes due to limitation of complex in-vessel geometry and narrow diagnostics port through cryostat. Total 5-channels will be vertically placed as symmetric with the mid-plain. One of the characteristic features of the vertically distributed channels is that each channel is viewing different poloidal angle, while the horizontally distributed channels are viewing different toroidal angle. This scheme also can be used on an investigation of the up-down asymmetry and the vertical oscillation of plasma. Simulation has been performed and the result will be discussed to verify the possibility and the estimated effectiveness of the scheme on this paper.

  10. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  11. An interactive visualization tool for multi-channel confocal microscopy data in neurobiology research

    KAUST Repository

    Yong Wan,

    2009-11-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist\\'s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system.

  12. Energy reduction using multi-channels optical wireless communication based OFDM

    Science.gov (United States)

    Darwesh, Laialy; Arnon, Shlomi

    2017-10-01

    In recent years, an increasing number of data center networks (DCNs) have been built to provide various cloud applications. Major challenges in the design of next generation DC networks include reduction of the energy consumption, high flexibility and scalability, high data rates, minimum latency and high cyber security. Use of optical wireless communication (OWC) to augment the DC network could help to confront some of these challenges. In this paper we present an OWC multi channels communication method that could lead to significant energy reduction of the communication equipment. The method is to convert a high speed serial data stream to many slower and parallel streams and vies versa at the receiver. We implement this concept of multi channels using optical orthogonal frequency division multiplexing (O-OFDM) method. In our scheme, we use asymmetrically clipped optical OFDM (ACO-OFDM). Our results show that the realization of multi channels OFDM (ACO-OFDM) methods reduces the total energy consumption exponentially, as the number of channels transmitted through them rises.

  13. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    Science.gov (United States)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  14. Advanced Modular, Multi-Channel, High Speed Fiber Optic Sensing System for Acoustic Emissions Monitoring, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Intelligent Fiber Optic Systems Corporation (IFOS) proposes to prove the feasibility of innovations based on ultra-light-weight, ultra-high-speed, multi-channel,...

  15. The impact of the multi-channel retail mix on online store choice: Does online experience matter?

    OpenAIRE

    Melis, Kristina; Campo, Katia; Breugelmans, Els; Lamey, Lien

    2015-01-01

    More and more grocery retailers are becoming multi-channel retailers, as they are opening an online alternative next to their traditional offline supermarkets. While the number of multi-channel grocery shoppers is also expanding at a fast growth rate, there are still large differences in online shopping frequency, and as a result, in the levels of experience with buying in the online grocery channel. This study wants to (i) identify the underlying drivers of online store choice and (ii) explo...

  16. A high-throughput, multi-channel photon-counting detector with picosecond timing

    Science.gov (United States)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  17. A high-throughput, multi-channel photon-counting detector with picosecond timing

    International Nuclear Information System (INIS)

    Lapington, J.S.; Fraser, G.W.; Miller, G.M.; Ashton, T.J.R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  18. Multi-channel electrical impedance tomography for regional tissue hydration monitoring.

    Science.gov (United States)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-06-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical

  19. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin

    2003-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images of terminal ballistics are presented. The software for object separating, profile calculating and 3D cavity reconstruction are described

  20. Design of multi-channel analyzer's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Yang Tao; Wei Yixiang

    2007-01-01

    A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)

  1. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic....... The dereverberation performance of the algorithm is evaluated using computer simulations with realistic hearing aid microphone signals including head-related effects. The algorithm is shown to work well with signals reverberated both by synthetic and by measured room impulse responses, achieving improvements...

  2. Multi-channel time-division integrator in HL-2A

    International Nuclear Information System (INIS)

    Yan Ji

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration (magnetic confinement controlled nuclear fusion device). To find out the details of on-going fusion reaction at different times is of important significance in achieving controlled nuclear fusion. We developed a new type multi-channel time-division integrator for HL-2A. It has functions of automatic cutting off negative pulse of the input signals, optional integrating time division spacing 0.2-1 ms, TTL starting trigger signal, automatic regularly work 20 s, and integrating 10 channel at the same time. (authors)

  3. Independent multi-channel analyzer with the color display and microcomputer in the CAMAC standard

    International Nuclear Information System (INIS)

    Gyunter, Z.; Elizarov, O.I.; Zhukov, G.P.; Mikhaehlis, B.; Shul'tts, K.Kh.

    1983-01-01

    An independent multi-channel time-of-flight analyzer developed for a spectrometer of polarised neutrons and used in experiments with the IBR-2 pulse reactor is described. Different cyclic modes of measuring are realized in the analyzer, 4 kwords of analyzer momory being assigned for each mode. The spectra are displayed on a colour screen during measurements. Simultaneous displaying of up to 8 spectra is possible. A microcomputer transfers the spectra from the buffer analyzer memory to the microcomputer memory. The accumulated information is transferred to the PDP-11/70 central computer

  4. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  5. A multi-channel photometric detector for multi-component analysis in flow injection analysis.

    Science.gov (United States)

    Tan, A; Huang, J; Geng, L; Xu, J; Zhao, X

    1994-01-01

    The detector, a multi-channel photometric detector, described in this paper was developed using multi-wavelength LEDs (light emitting diode) and phototransistors for absorbance measurement controlled by an Intel 8031 8-bit single chip microcomputer. Up to four flow cells can be attached to the detector. The LEDs and phototransistors are both inexpensive, and reliable. The results given by the detector for simultaneous determination of trace amounts of cobalt and cadmium in zinc sulphate electrolyte are reported. Because of the newly developed detector, this approach employs much less hardware apparatus than by employing conventional photometric detectors.

  6. Characteristics of crosstalk in the reproduced output of a newly developed multi-channel MR head

    International Nuclear Information System (INIS)

    Machida, K.; Hayashi, N.; Yoneda, Y.; Numazawa, J.; Kohro, M.; Tanabe, T.

    2001-01-01

    We prepared the multi-channel magnetoresistive head with a simple structural design and it has the advantages of high-density recording and ultra-high transfer rate. Characteristics of crosstalk in the reproduced output of our head have been estimated by a micromagnetic calculation using the Landau-Lifshitz-Gilbert (LLG) equation, while the specimen head was fabricated and evaluated. As a result, by applying a magnetic field of 40 Oe only between adjacent channels, the crosstalk was much decreased without reducing the reproduced output

  7. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  8. Reprocessing of multi-channel seismic-reflection data collected in the Chukchi Sea

    Science.gov (United States)

    Agena, W.F.; Lee, M.W.; Hart, P.E.

    2001-01-01

    Contained on this set of two CD-ROMs are stacked and migrated multi-channel seismic-reflection data for 44 lines recorded in the Chukchi Sea, northern Alaska, by the United States Geological Survey in 1977, 1978, and 1980. All data were reprocessed by the USGS in 2000 using updated methods. The resulting final data have both increased temporal and spatial resolution thus providing improved interpretability. An added benefit of these CD-ROMs is that they are a more stable, long-term archival medium for the data.

  9. Electro-optic tunable multi-channel filter in two-dimensional ferroelectric photonic crystals

    International Nuclear Information System (INIS)

    Fu, Yulan; Zhang, Jiaxiang; Hu, Xiaoyong; Gong, Qihuang

    2010-01-01

    An electro-optic tunable multi-channel filter is presented, which is based on a two-dimensional ferroelectric photonic crystal made of barium titanate. The filtering properties of the photonic crystal filter can be tuned by an applied voltage or by adjusting the structural parameters. The channel shifts about 30 nm under excitation of an applied voltage of 54.8 V. The influences of the structural disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed

  10. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...

  11. Applying a CPLD for Refurbishment of a Multi-channel Pulse Height Analyzer

    International Nuclear Information System (INIS)

    Leetragunpichitchai, Supalerk; Thong-Aram, Decho; Ploykrachang, Kamontip

    2007-08-01

    Full text: This research applied a CPLD for construction of a 100 MHz, 2048 channel, Wilkinson type analog to digital converter (ADC) circuits for refurbishment of an original multi-channel pulse height analyzer (PHA) ADC. Introduction of the CPLD could reduce the complexity of the circuits, equipment size and also the power consumption while the operation speed was increased. The linearity test of the ADC was found to be excellent with an R2 = 0.9995 and a maximum pulse rate of 48.828 k cps could be converted in this system. Therefore the developed system was appropriate for replacing the original ADC

  12. On a multi-channel transportation loss system with controlled input and controlled service

    Directory of Open Access Journals (Sweden)

    Jewgeni Dshalalow

    1987-01-01

    Full Text Available A multi-channel loss queueing system is investigated. The input stream is a controlled point process. The service in each of m parallel channels depends on the state of the system at certain moments of time when input and service may be controlled. To obtain explicitly the limiting distribution of the main process (Zt (the number of busy channels in equilibrium, an auxiliary three dimensional process with two additional components (one of them is a semi-Markov process is treated as semi-regenerative process. An optimization problem is discussed. Simple expressions for an objective function are derived.

  13. Investigation of ultra wideband multi-channel dichroic beamsplitters from 0.3 to 52 microns

    Science.gov (United States)

    Zhang, K. Q.; Hunneman, R.; Seeley, J. S.; Hawkins, G. J.

    1990-01-01

    The development of a set of multi-channel dichroics which includes a 6 channel dichroic operating over the wavelength region from 0.3 to 52 microns is described. In order to achieve the optimum performance, the optical constraints of PbTe, Ge, and CdTe coatings in the strongly absorptive region have been determined by use of a new iterative method using normal incidence reflectance measurement of the multilayer together with initial values of energy gap and infinite refractive index for the semiconductor model. The design and manufacture of the dichroics is discussed and the final results are presented.

  14. Development of a novel fast frequency modulation scheme for the JET multi-channel reflectometer

    International Nuclear Information System (INIS)

    Deliyanakis, N.

    1999-10-01

    A novel frequency modulation scheme has been developed for the multi-channel reflectometer used to measure density profiles and density fluctuations on the JET tokamak. This reflectometer normally uses slow frequency sweeping, combined with fixed-frequency operation, to measure the group delay, as well as plasma fluctuations, at 10 different microwave frequencies. The novel scheme uses continuous frequency modulation on a time-scale much faster than that of plasma fluctuations, the main aim being to make the group delay measurement more robust against plasma fluctuations. This paper discusses the theoretical background of the scheme, gives a detailed description of the system, and presents results from plasma measurements. (author)

  15. A Portable Multi-Channel γ Spectrometer Based on Bluetooth and PDA

    International Nuclear Information System (INIS)

    Yu Xinhua; Lai Wanchang; Zhang Zhen; Chen Xiaoqiang; Wang Guangxi; Yang Qiang

    2009-01-01

    Introduces an embedded GPS portable multi-channel γ spectrometer based on PDA and blue-tooth. PDA use HP iPAQ rx5700, it has GPS and bluetooth, the position accuracy of GPS isn't more than 5 m and the transmission rate of bluetooth can reach 1 MB/s, its communication distance is up to 10 m. The instrument detection limits of U, Th and K are 1.0 ppm. 1.8 ppm. 0.17%, respectively. The result of experiment proves γ spectrometer based on bluetooth and PDA has low-power, strong anti-interference capability and good portable capability. (authors)

  16. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  17. Development of a USB-based multi-channel time division scaler for HL-2A

    International Nuclear Information System (INIS)

    Liang Ping

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration. Mastering the process and plasma parameter changes with time are of great significance to achieve controlled nuclear fusion. In the recent upgrading of HL-2A, for which a higher and faster electronic equipment was required, we developed a new type USB multi-channel time division scaler for HL-2A including functions: USB interface, PC graphical user interface, simultaneously calibrating more than five channel signals, optional time division spacing 2-50 ms, count rate up to over 2 MHz, accessing all the information 20 s after a activated signal, and processing data and displaying off-line. (authors)

  18. Study on the dissociative recombination of HeH+ by multi-channel quantum defect theory

    Directory of Open Access Journals (Sweden)

    Takagi Hidekazu

    2015-01-01

    Full Text Available The dissociative recombination of HeH+ is studied using multi-channel quantum defect theory. We investigated how the partial waves of incident electrons affect the DR cross section. The DR cross section depends on the position of the center of partial wave expansion for the adiabatic S-matrix of electron scattering. When the Rydberg states correlate with the Rydberg states of the hydrogen atom at large internuclear distances, the center should be on the hydrogen atom for a better convergence of the expansion.

  19. Rayleigh waves ellipticity and mode mis-identification in multi-channel analysis of surface waves

    DEFF Research Database (Denmark)

    Boaga, Jacopo; Cassiani, Giorgio; Strobbia, Claudio

    dispersion curve which is then inverted. Typically, single component vertical and multi channel receivers are used. In most cases the inversion of the dispersion properties is carried out assuming that the experimental dispersion curve corresponds to a single mode, mostly the fundamental Rayleigh mode...... to each other reaching similar Rayleigh velocity. It is known ‘osculation’ happens generally in presence of strong velocity contrasts, typically with a fast bedrock underlying loose sediments. The practical limitations of the acquired data affect the spectral and modal resolution, making it often...

  20. Continuous Estimates of Surface Density and Annual Snow Accumulation with Multi-Channel Snow/Firn Penetrating Radar in the Percolation Zone, Western Greenland Ice Sheet

    Science.gov (United States)

    Meehan, T.; Marshall, H. P.; Bradford, J.; Hawley, R. L.; Osterberg, E. C.; McCarthy, F.; Lewis, G.; Graeter, K.

    2017-12-01

    A priority of ice sheet surface mass balance (SMB) prediction is ascertaining the surface density and annual snow accumulation. These forcing data can be supplied into firn compaction models and used to tune Regional Climate Models (RCM). RCMs do not accurately capture subtle changes in the snow accumulation gradient. Additionally, leading RCMs disagree among each other and with accumulation studies in regions of the Greenland Ice Sheet (GrIS) over large distances and temporal scales. RCMs tend to yield inconsistencies over GrIS because of sparse and outdated validation data in the reanalysis pool. Greenland Traverse for Accumulation and Climate Studies (GreenTrACS) implemented multi-channel 500 MHz Radar in multi-offset configuration throughout two traverse campaigns totaling greater than 3500 km along the western percolation zone of GrIS. The multi-channel radar has the capability of continuously estimating snow depth, average density, and annual snow accumulation, expressed at 95% confidence (+-) 0.15 m, (+-) 17 kgm-3, (+-) 0.04 m w.e. respectively, by examination of the primary reflection return from the previous year's summer surface.

  1. Masses and widths of scalar-isoscalar multi-channel resonances from data analysis

    Czech Academy of Sciences Publication Activity Database

    Surovtsev, Yu .S.; Bydžovský, Petr; Kaminski, R.; Lyubovitskij, V. E.; Nagy, M.

    2014-01-01

    Roč. 41, č. 2 (2014), 025006 ISSN 0954-3899 R&D Projects: GA ČR(CZ) GAP203/12/2126; GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : coupled-channel formalism * meson-meson scattering * scalar and pseudoscalar mesons Subject RIV: BE - Theoretical Physics Impact factor: 2.777, year: 2014

  2. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Directory of Open Access Journals (Sweden)

    Ying-Lun Chen

    2015-08-01

    Full Text Available A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO, and the feature extraction is carried out by the generalized Hebbian algorithm (GHA. To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  3. Scene text detection by leveraging multi-channel information and local context

    Science.gov (United States)

    Wang, Runmin; Qian, Shengyou; Yang, Jianfeng; Gao, Changxin

    2018-03-01

    As an important information carrier, texts play significant roles in many applications. However, text detection in unconstrained scenes is a challenging problem due to cluttered backgrounds, various appearances, uneven illumination, etc.. In this paper, an approach based on multi-channel information and local context is proposed to detect texts in natural scenes. According to character candidate detection plays a vital role in text detection system, Maximally Stable Extremal Regions(MSERs) and Graph-cut based method are integrated to obtain the character candidates by leveraging the multi-channel image information. A cascaded false positive elimination mechanism are constructed from the perspective of the character and the text line respectively. Since the local context information is very valuable for us, these information is utilized to retrieve the missing characters for boosting the text detection performance. Experimental results on two benchmark datasets, i.e., the ICDAR 2011 dataset and the ICDAR 2013 dataset, demonstrate that the proposed method have achieved the state-of-the-art performance.

  4. Salt intrusion in multi-channel estuaries: a case study in the Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    A. D. Nguyen

    2006-01-01

    Full Text Available There is a well-tested theory for the computation of salt intrusion in alluvial estuaries that is fully analytical and predictive. The theory uses analytical equations to predict the mixing behaviour of the estuary based on measurable quantities, such as channel topography, river discharge and tidal characteristics. It applies to single-channel topographies and estuaries that demonstrate moderate tidal damping. The Mekong delta is a multi-channel estuary where the tide is damped due to a relatively strong river discharge (in the order of 2000 m3/s, even during the dry season. As a result the Mekong is a strongly riverine estuary. This paper aims to test if the theory can be applied to such a riverine multi-channel estuary, and to see if possible adjustments or generalisations need to be made. The paper presents salt intrusion measurements that were done by moving boat in 2005, to which the salt intrusion model was calibrated. The theory has been expanded to cater for tidal damping. Subsequently the model has been validated with observations made at fixed locations over the years 1998 and 1999. Finally it has been tested whether the Mekong calibration fits the overall predictive equations derived in other estuaries. The test has been successful and led to a slight adjustment of the predictive equation to cater for estuaries that experience a sloping bottom.

  5. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  6. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2012-01-01

    Full Text Available The human hand has multiple degrees of freedom (DOF for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  7. Hand motion classification using a multi-channel surface electromyography sensor.

    Science.gov (United States)

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  8. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    International Nuclear Information System (INIS)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-01-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s −1 , the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay. (paper)

  9. Wireless acquisition of multi-channel seismic data using the Seismobile system

    Science.gov (United States)

    Isakow, Zbigniew

    2017-11-01

    This paper describes the wireless acquisition of multi-channel seismic data using a specialized mobile system, Seismobile, designed for subsoil diagnostics for transportation routes. The paper presents examples of multi-channel seismic records obtained during system tests in a configuration with 96 channels (4 landstreamers of 24-channel) and various seismic sources. Seismic waves were generated at the same point using different sources: a 5-kg hammer, a Gisco's source with a 90-kg pile-driver, and two other the pile-drivers of 45 and 70 kg. Particular attention is paid to the synchronization of source timing, the measurement of geometry by autonomous GPS systems, and the repeatability of triggering measurements constrained by an accelerometer identifying the seismic waveform. The tests were designed to the registration, reliability, and range of the wireless transmission of survey signals. The effectiveness of the automatic numbering of measuring modules was tested as the system components were arranged and fixed to the streamers. After measurements were completed, the accuracy and speed of data downloading from the internal memory (SDHC 32GB WiFi) was determined. Additionally, the functionality of automatic battery recharging, the maximum survey duration, and the reliability of battery discharge signalling were assessed.

  10. Metasurface for multi-channel terahertz beam splitters and polarization rotators

    Science.gov (United States)

    Zang, XiaoFei; Gong, HanHong; Li, Zhen; Xie, JingYa; Cheng, QingQing; Chen, Lin; Shkurinov, Alexander P.; Zhu, YiMing; Zhuang, SongLin

    2018-04-01

    Terahertz beam splitters and polarization rotators are two typical devices with wide applications ranging from terahertz communication to system integration. However, they are faced with severe challenges in manipulating THz waves in multiple channels, which is desirable for system integration and device miniaturization. Here, we propose a method to design ultra-thin multi-channel THz beam splitters and polarization rotators simultaneously. The reflected beams are divided into four beams with nearly the same density under illumination of linear-polarized THz waves, while the polarization of reflected beams in each channel is modulated with a rotation angle or invariable with respect to the incident THz waves, leading to the multi-channel polarization rotator (multiple polarization rotation in the reflective channels) and beam splitter, respectively. Reflective metasurfaces, created by patterning metal-rods with different orientations on a polyimide film, were fabricated and measured to demonstrate these characteristics. The proposed approach provides an efficient way of controlling polarization of THz waves in various channels, which significantly simplifies THz functional devices and the experimental system.

  11. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  12. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    Science.gov (United States)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  13. A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.

    Science.gov (United States)

    Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco

    2013-01-01

    Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.

  14. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    Science.gov (United States)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-05-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s-1, the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay.

  15. Application of a multi-channel system for continuous monitoring and an early warning system.

    Science.gov (United States)

    Lee, J H; Song, C H; Kim, B C; Gu, M B

    2006-01-01

    A multi-channel continuous toxicity monitoring system developed in our laboratory, based on two-stage mini-bioreactors, was successfully implemented in the form of computer-based data acquisition. The multi-channel system consists of a series of a two-stage minibioreactor systems connected by a fiber optic probe to a luminometer, and uses genetically engineered bioluminescent bacteria for the detection of the potential toxicity from the soluble chemicals. This system can be stably and continuously operated due to the separation of the culture reactor from the test reactor and accomplish easy and long-term monitoring without system shut down by abrupt inflows of severe polluting chemicals. Four different recombinant bioluminescent bacteria were used in different channels so that the modes of the samples toxicities can be reasonably identified and evaluated based upon the response signature of each channel. The bioluminescent signatures were delivered from four channels by switching one at once, while the data is automatically logged to an IBM compatible computer. We also achieved the enhancement of the system through the manipulation of the dilution rate and the use of thermo-lux fusion strains. Finally, this system is now being implemented to a drinking water reservoir and river for remote sensing as an early warning system.

  16. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  17. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

    Science.gov (United States)

    Córcoles, Juan; Zastrow, Earl; Kuster, Niels

    2017-06-01

    The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

  18. The designing principle and implementation of multi-channel intelligence isotope thickness gauge based on multifunction card PCI-1710

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Guo Maotian; He Jintian

    2006-01-01

    The designing principle, the constitution of system and the implementation of multi-channel intelligence isotope thickness gauge are introduced in the paper in detail, which are based on multifunction card PCI-1710. The paper also discusses the primaryprinciple of isotope thickness gauge, correct factor in measurement and complication of calibration. In the following, the whole frame of multi-channel intelligence isotope thickness gauge is given. The functions, the characteristics and the usage of multifunction card PCI-1710 are described. Furthermore, the developing process and the function modules of software are presented. Finally, the real prototype of multi-channel intelligence isotope thickness gauge is introduced, using 241 Am as a radioactive element. (authors)

  19. Multi-channel electrical impedance tomography for regional tissue hydration monitoring

    International Nuclear Information System (INIS)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-01-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ∼35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in

  20. Compact and cost-effective multi-channel optical spectrometer for fine FBG sensing in IoT technology

    Science.gov (United States)

    Konishi, Tsuyoshi; Yamasaki, Yu

    2018-02-01

    Optical fiber sensor networks have attracted much attention in IoT technology and a fiber Bragg grating is one of key sensor devices there because of their advantages in a high affinity for optical fiber networks, compactness, immunity to electromagnetic interference and so on. Nevertheless, its sensitivity is not always satisfactory so as to be usable together with widespread cost-effective multi-channel spectrometers. In this paper, we introduce a new cost-effective approach for a portable multi-channel spectrometer with high spectral resolution and demonstrates some preliminary experimental results for fine FBG sensing.

  1. Automatic pickup of arrival time of channel wave based on multi-channel constraints

    Science.gov (United States)

    Wang, Bao-Li

    2018-03-01

    Accurately detecting the arrival time of a channel wave in a coal seam is very important for in-seam seismic data processing. The arrival time greatly affects the accuracy of the channel wave inversion and the computed tomography (CT) result. However, because the signal-to-noise ratio of in-seam seismic data is reduced by the long wavelength and strong frequency dispersion, accurately timing the arrival of channel waves is extremely difficult. For this purpose, we propose a method that automatically picks up the arrival time of channel waves based on multi-channel constraints. We first estimate the Jaccard similarity coefficient of two ray paths, then apply it as a weight coefficient for stacking the multichannel dispersion spectra. The reasonableness and effectiveness of the proposed method is verified in an actual data application. Most importantly, the method increases the degree of automation and the pickup precision of the channel-wave arrival time.

  2. Research on Intelligent Control System of DC SQUID Magnetometer Parameters for Multi-channel System

    Science.gov (United States)

    Chen, Hua; Yang, Kang; Lu, Li; Kong, Xiangyan; Wang, Hai; Wu, Jun; Wang, Yongliang

    2018-03-01

    In a multi-channel SQUID measurement system, adjusting device parameters to optimal condition for all channels is time-consuming. In this paper, an intelligent control system is presented to determine the optimal working point of devices which is automatic and more efficient comparing to the manual one. An optimal working point searching algorithm is introduced as the core component of the control system. In this algorithm, the bias voltage V_bias is step scanned to obtain the maximal value of the peak-to-peak current value I_pp of the SQUID magnetometer modulation curve. We choose this point as the optimal one. Using the above control system, more than 30 weakly damped SQUID magnetometers with area of 5 × 5 mm^2 or 10 × 10 mm^2 are adjusted and a 36-channel magnetocardiography system perfectly worked in a magnetically shielded room. The average white flux noise is 15 μΦ_0/Hz^{1/2}.

  3. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  4. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  5. Design of a novel multi channel photonic crystal fiber polarization beam splitter

    Science.gov (United States)

    Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun

    2017-10-01

    A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.

  6. A customizable multi-channel loudness compensation method based on WDRC for digital hearing aids

    Science.gov (United States)

    Hu, Jiebin; Wang, Mingjiang; Ma, Min

    2017-08-01

    Loudness compensation is the most significant signal processing algorithm in digital hearing aids at present. An algorithm of multi-channel loudness compensation for embedded system has been put forward in this paper. The number of channels is customizable in this algorithm. The algorithm can set different number and different width of channels for each patient based on frequency domain wide dynamic range compression. First, according to the requirement of patient to divide the frequency domain into multiple unequal frequency bands. And then calculate the gain of each channel according to the input-output curve of sound pressure level. Finally, the time-domain impulse response of gain is computed from Mel filter banks. It is used in conjunction with speech enhancement processing in hearing aids. Simulation results show that the algorithm can effectively enhance the loudness for different frequencies.

  7. Development of a multi-channel horn mixer array for microwave imaging plasma diagnostics

    International Nuclear Information System (INIS)

    Ito, Naoki; Kuwahara, Daisuke; Nagayama, Yoshio

    2015-01-01

    Microwave to millimeter-wave diagnostics techniques, such as interferometry, reflectometry, scattering, and radiometry, have been powerful tools for diagnosing magnetically confined plasmas. The resultant measurements have clarified several physics issues, including instability, wave phenomena, and fluctuation-induced transport. Electron cyclotron emission imaging has been an important tool in the investigation of temperature fluctuations, while reflectometry has been employed to measure plasma density profiles and their fluctuations. We have developed a horn-antenna mixer array (HMA), a 50 - 110 GHz 1D antenna array, which can be easily stacked as a 2D array. This article describes an upgrade to the horn mixer array that combines well-characterized mixers, waveguide-to-microstrip line transitions, intermediate frequency amplifiers, and internal local oscillator modules using a monolithic microwave integrated circuit technology to improve system performance. We also report on the use of a multi-channel HMA system. (author)

  8. A low delay transmission method of multi-channel video based on FPGA

    Science.gov (United States)

    Fu, Weijian; Wei, Baozhi; Li, Xiaobin; Wang, Quan; Hu, Xiaofei

    2018-03-01

    In order to guarantee the fluency of multi-channel video transmission in video monitoring scenarios, we designed a kind of video format conversion method based on FPGA and its DMA scheduling for video data, reduces the overall video transmission delay.In order to sace the time in the conversion process, the parallel ability of FPGA is used to video format conversion. In order to improve the direct memory access (DMA) writing transmission rate of PCIe bus, a DMA scheduling method based on asynchronous command buffer is proposed. The experimental results show that this paper designs a low delay transmission method based on FPGA, which increases the DMA writing transmission rate by 34% compared with the existing method, and then the video overall delay is reduced to 23.6ms.

  9. A high-throughput, multi-channel photon-counting detector with picosecond timing

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchanne...

  10. [Analysis of the Muscle Fatigue Based on Band Spectrum Entropy of Multi-channel Surface Electromyography].

    Science.gov (United States)

    Liu, Jian; Zou, Renling; Zhang, Dongheng; Xu, Xiulin; Hu, Xiufang

    2016-06-01

    Exercise-induced muscle fatigue is a phenomenon that the maximum voluntary contraction force or power output of muscle is temporarily reduced due to muscular movement.If the fatigue is not treated properly,it will bring about a severe injury to the human body.With multi-channel collection of lower limb surface electromyography signals,this article analyzes the muscle fatigue by adoption of band spectrum entropy method which combined electromyographic signal spectral analysis and nonlinear dynamics.The experimental result indicated that with the increase of muscle fatigue,muscle signal spectrum began to move to low frequency,the energy concentrated,the system complexity came down,and the band spectrum entropy which reflected the complexity was also reduced.By monitoring the entropy,we can measure the degree of muscle fatigue,and provide an indicator to judge fatigue degree for the sports training and clinical rehabilitation training.

  11. The interaction between room and musical instruments studied by multi-channel auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    in the anechoic recording. With this technique the variations in sound radiation from the musical instrument during the performance e.g. due to changes in level or movements can be reproduced with the influence of the surrounding room surfaces. Examples include a grand piano and a clarinet.......The directivity of musical instruments is very complicated and typically changes from one tone to the next. So, instead of measuring the average directivity, a multi-channel auralization method has been developed, which allows a highly accurate and realistic sounding auralization of musical...... instruments in rooms. Anechoic recordings have been made with 5 and 13 evenly distributed microphones around the musical instrument. The reproduction is made with a room acoustics simulation software using a compound source, which is in fact a number of highly directive sources, one for each of the channels...

  12. Multi-channel, passive, short-range anti-aircraft defence system

    Science.gov (United States)

    Gapiński, Daniel; Krzysztofik, Izabela; Koruba, Zbigniew

    2018-01-01

    The paper presents a novel method for tracking several air targets simultaneously. The developed concept concerns a multi-channel, passive, short-range anti-aircraft defence system based on the programmed selection of air targets and an algorithm of simultaneous synchronisation of several modified optical scanning seekers. The above system is supposed to facilitate simultaneous firing of several self-guided infrared rocket missiles at many different air targets. From the available information, it appears that, currently, there are no passive self-guided seekers that fulfil such tasks. This paper contains theoretical discussions and simulations of simultaneous detection and tracking of many air targets by mutually integrated seekers of several rocket missiles. The results of computer simulation research have been presented in a graphical form.

  13. Study of multi-channel readout ASIC and its discrete module for particle detector

    International Nuclear Information System (INIS)

    Wang Ke; Fan Lei; Zhang Shengjun; Li Xian

    2013-01-01

    Recently, kinds of particle detectors have used Application Specific Integrated Circuits (ASIC) in their electronics readout systems, it is the key part for the whole system. This project designed a multi-channel readout ASIC for general detectors. The chip has Preamplifier, Shaper and Peak Detector embedded for easy readout. For each channel, signal which is preprocessed by a low-noise preamplifier is sent to the shaper to form a quasi-Gaussian pulse and keep its peak for readout. This chip and modules of individual Preamplifier, Shaper and Peak Detector have been manufactured and tested. The discrete modules work well, and the 6-channel chip NPRE 6 is ready for test in some particle detection system. (authors)

  14. FPGA based high-performance multi-channel analyzer with local histogram memory

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.

    2004-01-01

    Modern nuclear spectroscopy systems demand for a Multi-Channel Analyzer (MCA) with higher resolution, faster speed and other advanced features. The MCA described here is targeted for such demanding applications. The MCA has an in-built local histogram memory and a memory management unit integrated in an FPGA (Field Programmable Gate Array) chip. In addition to the integrated low power digital circuitry, the system utilizes state of the art advanced analog circuits like low power, high speed and high precision comparators, op-amps, ADC and DAC. The operating resolution is selectable from 256 channels to 16384 channels for pulse height analysis. It supports high count rate applications (typically 100 KHz) without significant dead time penalty. It can have an USB bus interface with simple changes. In general, the MCA gives a high performance, compact and low power alternative for portable and battery operated systems as well as for high end laboratory instruments. (author)

  15. Investigating the astrophysical 22Ne(p, γ23Na and 22Mg(p, γ23Al reactions with a multi-channel scattering formalism

    Directory of Open Access Journals (Sweden)

    Fraser P. R.

    2014-03-01

    Full Text Available The reaction 22Ne(p, γ23Na is key to the NeNa cycle of stellar nucleogenesis, and better understanding of the 22Mg(p, γ23Al reaction is needed to understand the 22Na puzzle in ONe white dwarf novae. We aim to study these reactions using a multi-channel algebraic scattering (MCAS formalism for low-energy nucleon-nucleus scattering, recently expanded to investigate radiative capture. As a first step towards this goal, we here calculate the energy levels of the mass-23 (Ne, Mg, Na, Al nuclei. This is not only because the resonant structure of these nuclei are related to the astrophysical -rates of interest, but also because the interaction parameters determined for describing the energy levels are an integral part of the future calculation of the astrophysical reactions when using the MCAS scheme.

  16. Satellite rainfall monitoring over Africa for food security, using multi-channel MSG data

    Science.gov (United States)

    Chadwick, R.; Grimes, D.; Saunders, R.; Blackmore, T.; Francis, P.

    2009-04-01

    Near real-time rainfall estimates are crucial in sub-Saharan Africa for a variety of humanitarian and agricultural purposes. However, for economic and infrastructural reasons, regularly reporting rain-gauges are sparse and precipitation radar networks extremely rare. Satellite rainfall estimates, particularly from geostationary satellites such as Meteosat Second Generation (MSG), present one method of filling this information gap, as they produce data at high temporal and spatial resolution. An algorithm has been developed to produce rainfall estimates for Africa from multi-channel MSG data. The algorithm is calibrated using precipitation radar data collected in Niamey, Niger as part of the African Monsoon Multidisciplinary Analyses (AMMA) project in 2006, and is based on an algorithm used operationally over Europe by the UK Met Office. Contingency tables are used to establish a statistical relationship between multi-channel MSG data and probability of rainfall at several different rain-rate magnitudes as sensed by the radar. Rain-rate estimates can then be produced at a variety of spatial and temporal scales, with MSG scan length (15 minutes) and pixel size (3-4km) as the lower limit. Results will be presented of a validation of this algorithm over the Sahel region of Africa. Rainfall estimates from this algorithm, processed for 2004, will be validated against gridded rain-gauge data at a 0.5 degree and 10 day timescale suitable for drought monitoring purposes. A comparison will also be made against rainfall estimates from the TAMSAT algorithm, which uses single channel IR data from MSG, and has been shown to perform well in the Sahel region.

  17. Scale-free brain quartet: artistic filtering of multi-channel brainwave music.

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective.

  18. Effect of flow rate distribution at the inlet on hydrodynamic mixing in narrow rectangular multi-channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Chen Bingde; Wang Xiaojun

    2008-01-01

    Flow and heat transfer in the narrow rectangular multi-channel is widely en- countered in the engineering application, hydrodynamic mixing in the narrow rectangular multi-channel is one of the important concerns. With the help of the Computational Fluid Dynamics code CFX, the effect of flow rate distribution of the main channel at the inlet on hydrodynamic mixing in the narrow rectangular multi-channel is numerical simulated. The results show that the flow rate distributions at the inlet have a great effect on hydrodynamics mixing in multi-channel, the flow rate in the main channel doesn't change with increasing the axial mixing section when the average flow rate at the inlet is set. Hydrodynamic mixing will arise in the mixing section when the different ratio of the flow rate distribution at the inlet is set, and hydrodynamic mixing increases with the difference of the flow rate distribution at the inlet increase. The trend of the flow rate distribution of the main channel is consistent during the whole axial mixing section, and hydrodynamic mixing in former 4 mixing section is obvious. (authors)

  19. Surface Clutter Suppression Techniques Applied to P-band Multi-Channel SAR Ice Sounder Data from East Antarctica

    DEFF Research Database (Denmark)

    Lin, Chung-Chi; Bekaert, David; Gebert, Nicolas

    ., Lausanne, developed and built the radiator-elements of the enhanced POLARIS. Several datasets were acquired in the multi-channel configuration during the Feb. 2011 campaign over East Antarctica. The POLARIS instrument will be briefly introduced, followed by an overview of the sounding campaign. Finally...

  20. A Novel Spectrally Efficient Asynchronous Multi-Channel MAC Using a Half-Duplex Transceiver for Wireless Networks

    Directory of Open Access Journals (Sweden)

    Abdullah Devendiran

    2018-01-01

    Full Text Available Multi-channel medium access control (MAC protocols maximize network performance by enabling concurrent wireless transmissions over non-interfering channels. Despite physical layer advancements, the underlying IEEE 802.11 MAC standard cannot fully exploit features and support high-performance applications. In this work, we propose the novel spectrally efficient asynchronous multi-channel MAC (SA-MMAC protocol for wireless networks using a single half-duplex transceiver. A full-duplex mode of operation on data channels reduces the signaling overhead and boosts the spectrum efficiency. A revamped contention mechanism of IEEE 802.11 addresses the multi-channel hidden terminal problem, and a jamming signal from the receiver addresses the collisions in control signals. Furthermore, the control channel is used for data transmissions to increase the bandwidth utilization but under a restricted half-duplex mode to avoid causing a bottleneck situation. The simulator is tested for correctness. The results suggest that the protocol can work well on 3, 4, or 12 concurrent channels with high node density, providing about 12.5 times more throughput than IEEE 802.11 and 18% to 95% more throughput than its multi-channel variants under saturated traffic conditions.

  1. Feasibility study of applying a multi-channel analysis model to on-line core monitoring system

    International Nuclear Information System (INIS)

    In, W. K.; Yoo, Y. J.; Hwang, D. H.; Jun, T. H.

    1998-01-01

    A feasibility study was performed to evaluate the effect of implementing a multi-channel analysis model in on-line core monitoring system. A simplified thermal-hydraulic model has been used in the on-line core monitoring system of digital PWR. The design procedure, core thermal margin and computation time were investigated in case of replacing the simplified model with the multi-channel analysis model. For the given ranges of limiting conditions for operation in Yonggwang Unit 3 Cycle 1, the minimum DNBR of the simplified thermal-hydraulic code CETOP-D was compared to that of the multi-channel analysis code MATRA. A CETOP-D tuning is additionally required to ensure the accurate and conservative DNBR calculation but the MATRA tuning is not necessary. MATRA appeared to increase the DNBR overpower margin from 2.5% to 6% over the CETOP-D margin. MATRA took approximately 1 second to compute DNBR on the HP9000 workstation system, which is longer than the DNBR computation time of CETOP-D. It is, however, fast enough to perform the on-line monitoring of DNBR. It can be therefore concluded that the application of the multi-channel analysis model MATRA in the on-line core monitoring system is feasible

  2. Analysis of multi-channel seismic reflection and magnetic data along 13 degrees N latitude across the Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, D.G.; Bhattacharya, G.C.; Ramana, M.V.; Subrahmanyam, V.; Ramprasad, T.; Krishna, K.S.; Chaubey, A.K.; Murty, G.P.S.; Srinivas, K.; Desa, M.; Reddy, S.I.; Ashalata, B.; Subrahmanyam, C.; Mital, G.S.; Drolia, R.K.; rai, S.N.; Ghosh, S.K.; Singh, R.N.; Majumdar, M.

    Analysis of the multi-channel seismic reflection, magnetic and bathymetric data collected along a transect, 1110 km long parallel to 13 degrees N lat. across the Bay of Bengal was made. The transect is from the continental shelf off Madras...

  3. Childhood body mass index and multiple sclerosis risk

    DEFF Research Database (Denmark)

    Munger, Kassandra L; Bentzen, Joan; Laursen, Bjarne

    2013-01-01

    BACKGROUND: Obesity in late adolescence has been associated with an increased risk of multiple sclerosis (MS); however, it is not known if body size in childhood is associated with MS risk. METHODS: Using a prospective design we examined whether body mass index (BMI) at ages 7-13 years...

  4. Genetically Predicted Body Mass Index and Breast Cancer Risk

    DEFF Research Database (Denmark)

    Guo, Yan; Warren Andersen, Shaneda; Shu, Xiao-Ou

    2016-01-01

    BACKGROUND: Observational epidemiological studies have shown that high body mass index (BMI) is associated with a reduced risk of breast cancer in premenopausal women but an increased risk in postmenopausal women. It is unclear whether this association is mediated through shared genetic or enviro...

  5. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    International Nuclear Information System (INIS)

    Nasr, Amgad

    2012-01-01

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N 2 , Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  6. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Amgad

    2012-07-18

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N{sub 2}, Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  7. EFFICIENCY OF REDUNDANT QUERY EXECUTION IN MULTI-CHANNEL SERVICE SYSTEMS

    Directory of Open Access Journals (Sweden)

    V. A. Bogatyrev

    2016-03-01

    Full Text Available Subject of Research.The paper deals with analysis of the effectiveness of redundant queries based on untrusted computing in computer systems, represented by multi-channel queuing systems with a common queue. The objective of research is the possibility of increasing the efficiency of service requests while performing redundant copies of requests in different devices of a multi-channel system under conditions of calculations unreliability. The redundant service of requests requires the infallibility of its implementation at least in one of the devices.Method. We have considered estimation of the average time spent in the system with and without the use of redundant requests at the presentation of a simple queuing model of the M / M / n type to analyze the effectiveness of redundant service of requests. Presented evaluation of the average waiting time in the redundant queries is the upper one, since it ignores the possibility of reducing the average waiting time as a result of the spread of the probability of time querying at different devices. The integrated efficiency of redundant service of requests is defined based on the multiplicative index that takes into account the infallibility of calculations and the average time allowance with respect to the maximum tolerated delay of service. Evaluation of error-free computing at reserved queries is received at the requirement of faultless execution of at least one copy of the request. Main Results. We have shown that the reservation of requests gives the gain in efficiency of the system at low demand rate (load. We have defined the boundaries of expediency (efficiency for redundant service of requests. We have shown the possibility of the effectiveness increasing of the adaptive changes in the multiplicity of the reservation of requests, depending on the intensity of the flow of requests. We have found out that the choice of service discipline in information service systems is largely determined by

  8. Optimization of multi-channel neutron focusing guides for extreme sample environments

    International Nuclear Information System (INIS)

    Di Julio, D D; Lelièvre-Berna, E; Andersen, K H; Bentley, P M; Courtois, P

    2014-01-01

    In this work, we present and discuss simulation results for the design of multichannel neutron focusing guides for extreme sample environments. A single focusing guide consists of any number of supermirror-coated curved outer channels surrounding a central channel. Furthermore, a guide is separated into two sections in order to allow for extension into a sample environment. The performance of a guide is evaluated through a Monte-Carlo ray tracing simulation which is further coupled to an optimization algorithm in order to find the best possible guide for a given situation. A number of population-based algorithms have been investigated for this purpose. These include particle-swarm optimization, artificial bee colony, and differential evolution. The performance of each algorithm and preliminary results of the design of a multi-channel neutron focusing guide using these methods are described. We found that a three-channel focusing guide offered the best performance, with a gain factor of 2.4 compared to no focusing guide, for the design scenario investigated in this work.

  9. TRANTHAC-1: transient thermal-hydraulic analysis code for HTGR core of multi-channel model

    International Nuclear Information System (INIS)

    Sato, Sadao; Miyamoto, Yoshiaki

    1980-08-01

    The computer program TRANTHAC-1 is for predicting thermal-hydraulic transient behavior in HTGR's core of pin-in-block type fuel elements, taking into consideration of the core flow distribution. The program treats a multi-channel model, each single channel representing the respective column composed of fuel elements. The fuel columns are grouped in flow control regions; each region is provided with an orifice assembly. In the region, all channels are of the same shape except one channel. Core heat is removed by downward flow of the control through the channel. In any transients, for given time-dependent power, total core flow, inlet coolant temperature and coolant pressure, the thermal response of the core can be determined. In the respective channels, the heat conduction in radial and axial direction are represented. And the temperature distribution in each channel with the components is calculated. The model and usage of the program are described. The program is written in FORTRAN-IV for computer FACOM 230-75 and it is composed of about 4,000 cards. The required core memory is about 75 kilowords. (author)

  10. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Santos, D.M.; Chau, A.; DeBusshere, D.; Dow, S.; Flasck, J.; Levi, M.; Kirsten, F.; Su, E.

    1995-12-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e. 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using one eight channel TDC comprised of a delay locked loop and eight sets of latches and encoders. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. The timing and amplitude information is multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are then transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in a 0.8μ triple metal CMOS process. The TDC sub-element has been measured to have better than 135 ps time resolution and 35 ps jitter. The DRAM has a measured cycle time of 80 MHz

  11. Stochastic geometry model for multi-channel fog radio access networks

    KAUST Repository

    Emara, Mostafa

    2017-06-29

    Cache-enabled base station (BS) densification, denoted as a fog radio access network (F-RAN), is foreseen as a key component of 5G cellular networks. F-RAN enables storing popular files at the network edge (i.e., BS caches), which empowers local communication and alleviates traffic congestions at the core/backhaul network. The hitting probability, which is the probability of successfully transmitting popular files request from the network edge, is a fundamental key performance indicator (KPI) for F-RAN. This paper develops a scheduling aware mathematical framework, based on stochastic geometry, to characterize the hitting probability of F-RAN in a multi-channel environment. To this end, we assess and compare the performance of two caching distribution schemes, namely, uniform caching and Zipf caching. The numerical results show that the commonly used single channel environment leads to pessimistic assessment for the hitting probability of F-RAN. Furthermore, the numerical results manifest the superiority of the Zipf caching scheme and quantify the hitting probability gains in terms of the number of channels and cache size.

  12. A generic EEG artifact removal algorithm based on the multi-channel Wiener filter

    Science.gov (United States)

    Somers, Ben; Francart, Tom; Bertrand, Alexander

    2018-06-01

    Objective. The electroencephalogram (EEG) is an essential neuro-monitoring tool for both clinical and research purposes, but is susceptible to a wide variety of undesired artifacts. Removal of these artifacts is often done using blind source separation techniques, relying on a purely data-driven transformation, which may sometimes fail to sufficiently isolate artifacts in only one or a few components. Furthermore, some algorithms perform well for specific artifacts, but not for others. In this paper, we aim to develop a generic EEG artifact removal algorithm, which allows the user to annotate a few artifact segments in the EEG recordings to inform the algorithm. Approach. We propose an algorithm based on the multi-channel Wiener filter (MWF), in which the artifact covariance matrix is replaced by a low-rank approximation based on the generalized eigenvalue decomposition. The algorithm is validated using both hybrid and real EEG data, and is compared to other algorithms frequently used for artifact removal. Main results. The MWF-based algorithm successfully removes a wide variety of artifacts with better performance than current state-of-the-art methods. Significance. Current EEG artifact removal techniques often have limited applicability due to their specificity to one kind of artifact, their complexity, or simply because they are too ‘blind’. This paper demonstrates a fast, robust and generic algorithm for removal of EEG artifacts of various types, i.e. those that were annotated as unwanted by the user.

  13. Automatic seizure detection based on the combination of newborn multi-channel EEG and HRV information

    Science.gov (United States)

    Mesbah, Mostefa; Balakrishnan, Malarvili; Colditz, Paul B.; Boashash, Boualem

    2012-12-01

    This article proposes a new method for newborn seizure detection that uses information extracted from both multi-channel electroencephalogram (EEG) and a single channel electrocardiogram (ECG). The aim of the study is to assess whether additional information extracted from ECG can improve the performance of seizure detectors based solely on EEG. Two different approaches were used to combine this extracted information. The first approach, known as feature fusion, involves combining features extracted from EEG and heart rate variability (HRV) into a single feature vector prior to feeding it to a classifier. The second approach, called classifier or decision fusion, is achieved by combining the independent decisions of the EEG and the HRV-based classifiers. Tested on recordings obtained from eight newborns with identified EEG seizures, the proposed neonatal seizure detection algorithms achieved 95.20% sensitivity and 88.60% specificity for the feature fusion case and 95.20% sensitivity and 94.30% specificity for the classifier fusion case. These results are considerably better than those involving classifiers using EEG only (80.90%, 86.50%) or HRV only (85.70%, 84.60%).

  14. Experimental test results of multi-channel test rig of T1 test section, 5

    International Nuclear Information System (INIS)

    Hino, Ryutaro; Takase, Kazuyuki; Miyamoto, Yoshiaki

    1990-09-01

    Channel blockage test on a fuel column of the high temperature engineering test reactor (HTTR) has been performed under the helium gas atmosphere at a high temperature and a high pressure in order to obtain safety data on flow rate and temperature distributions in the fuel column with the multi-channel test rig of the fuel stack test section (T 1 ) in HENDEL. In the test, one of 12 fuel channels was blockaded to 90% of flow area at the channel inlet. Experimental results showed that the helium gas flow rate in the blockaded channel was 28%∼33% lower than the average flow rate for Reynolds number from 2300 to 14000 in isothermal flow. When simulated fuel rods were heated, the flow rate in the blockaded channel did not decrease down in comparison with the isothermal flow. This is due to that the heat generated in the fuel rods conducts to the other fuel channels in graphite fuel blocks, so that accelerated pressure losses in the fuel channels change with helium gas temperatures. (author)

  15. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  16. The Research of China's Civil Aviation Passenger Multi-Channel Service Technology Platform

    Science.gov (United States)

    Zhibing, Xue; Xinming, Wang

    IATA is promoting Simplifying the Business. The traditional passenger services and business process, such as ticketing, airport counters, had a great influence. The airlines have the passenger service and convenience as the next product development requirements. With civil aviation industry and their company's products construction, the authors propose a solution of passenger multi-channel service product platform. The solution is to streamline the business as the breakthrough point, around the convenience of passengers travel services to travelers as the center, using the current mainstream and the latest IT technology to establish passenger service product platform. The solution will promote DCS e-ticketing business development and service channel diversity. In this paper, the research results have been applied in the product platform construction of the authors' company. The practice shows that through traditional business with the latest IT technologies, traditional passenger services into the emerging service model, passenger service product platform has strong advantages and characteristics. Based on the platform, various types of service products is growing rapidly.

  17. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    Science.gov (United States)

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892

  18. A multi-channel model for an α plus {sup 6}He nucleus cluster

    Energy Technology Data Exchange (ETDEWEB)

    Amos, K.; Karataglidis, S. [University of Melbourne, School of Physics, Victoria (Australia); University of Johannesburg, Department of Physics, Auckland Park (South Africa); Canton, L. [Istituto Nazionale di Fisica Nucleare, Padova (Italy); Fraser, P.R. [Curtin University, Department of Physics, Astronomy and Medical Radiation Sciences, Perth (Australia); Svenne, J.P. [Department of Physics and Astronomy, University of Manitoba, and Winnipeg Institute for Theoretical Physics, Winnipeg, MB (Canada); Van der Knijff, D. [University of Melbourne, School of Physics, Victoria (Australia)

    2017-04-15

    A multi-channel algebraic scattering (MCAS) method has been used to solve coupled sets of Lippmann-Schwinger equations for the α + {sup 6}He cluster system, so finding a model spectrum for {sup 10}Be to more than 10MeV excitation. Three states of {sup 6}He were included and the resonance character of the two excited states taken into account in finding solutions. A model Hamiltonian has been found that gives very good agreement with the known bound states and with some low-lying resonances of {sup 10}Be. More resonance states are predicted than those which have been observed as yet. The method also yields S-matrices which we have used to evaluate low-energy {sup 6}He-α scattering cross sections. Reasonable reproduction of low-energy differential cross sections and of energy variation of cross sections measured at fixed scattering angles have been found. Enlarging the channel space by including two higher energy states of {sup 6}He, assuming values for their spin-parities, leads to an enlarged spectrum for {sup 10}Be in which the number and distribution of resonances show similarity to the known spectrum. (orig.)

  19. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  20. Superpixel-based segmentation of muscle fibers in multi-channel microscopy.

    Science.gov (United States)

    Nguyen, Binh P; Heemskerk, Hans; So, Peter T C; Tucker-Kellogg, Lisa

    2016-12-05

    Confetti fluorescence and other multi-color genetic labelling strategies are useful for observing stem cell regeneration and for other problems of cell lineage tracing. One difficulty of such strategies is segmenting the cell boundaries, which is a very different problem from segmenting color images from the real world. This paper addresses the difficulties and presents a superpixel-based framework for segmentation of regenerated muscle fibers in mice. We propose to integrate an edge detector into a superpixel algorithm and customize the method for multi-channel images. The enhanced superpixel method outperforms the original and another advanced superpixel algorithm in terms of both boundary recall and under-segmentation error. Our framework was applied to cross-section and lateral section images of regenerated muscle fibers from confetti-fluorescent mice. Compared with "ground-truth" segmentations, our framework yielded median Dice similarity coefficients of 0.92 and higher. Our segmentation framework is flexible and provides very good segmentations of multi-color muscle fibers. We anticipate our methods will be useful for segmenting a variety of tissues in confetti fluorecent mice and in mice with similar multi-color labels.

  1. Measurements of void fraction by an improved multi-channel conductance void meter

    International Nuclear Information System (INIS)

    Song, Chul-Hwa; Chung, Moon Ki; No, Hee Cheon

    1998-01-01

    An improved multi-channel Conductance Void Meter (CVM) was developed to measure a void fraction. Its measuring principle is basically based upon the differences of electrical conductance of a two-phase mixture due to the variation of void fraction around a sensor. The sensor is designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. It is emphasized that the guard electrodes are electrically shielded in order not to affect the measurements of two-phase mixture conductance, but to make the electric fields evenly distributed in a measuring volume. Void fraction is measured for bubbly and slug flow regimes in a vertical air-water loop, and statistical signal processing techniques are applied to show that CVM has a good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel. (author)

  2. Concept and Development Status of the Digital Upgrade of the Mini Multi-Channel Analyser (DMCA)

    International Nuclear Information System (INIS)

    Brutscher, J.; Birnbaum, A.; Keubler, J.; Jung, S.; Koestlbauer, M.; Richter, B.; Schwalbach, P.; Zweidorf, A. von

    2010-01-01

    The Mini Multi Channel Analyser (MMCA) is a portable electronics module used for neutron and gamma ray Non-Destructive Assay (NDA) of nuclear material. The MMCA is widely used in nuclear safeguards to perform certain classes of verification activities on nuclear material. For more than a decade, an important but non-exclusive area of application has been low- and medium-resolution gamma spectroscopy and attribute testing. To make use of advances in digital technology, communication protocols and standardisation, display technology, and user interaction paradigms, while preserving the main functionality and compatibility with the existing MMCA, a digital upgrade of the MMCA (DMCA) is being developed in the frame of the German Support Programme to the International Atomic Energy Agency (IAEA) with cooperation of the European Commission. The DMCA is dubbed MCA-527. At the same time, a data acquisition and analysis software interface optimized for in-field use is being developed (''MCAtouch''). In this paper, development status and performance parameters of the digital MCA-527 as well as the software interface MCAtouch are discussed in the context of safeguards requirements for typical in-field applications. (author)

  3. Subjective evaluation of auralizations created from multi-channel anechoic recordings of a talker in motion

    Science.gov (United States)

    Vigeant, Michelle C.; Wang, Lily M.

    2005-04-01

    A high degree of speech intelligibility is very important in educational environments. When designing such spaces, like classrooms, auralizations can be used to subjectively assess the degree of speech intelligibility and clarity. Auralizations are most commonly made by convolving the impulse response (IR) of an omni-directional source with a single channel anechoic speech recording. This paper explores the idea of using multi-channel recordings to create the auralizations, using a female talker in motion. An omni-directional source is split into quadrants and the IR is calculated for each section. These IR's are convolved with the appropriate channel of the anechoic recording and then the four auralizations are mixed to create one final auralization. The auralizations were made using four-channel anechoic recordings of a person walking on a platform while talking. Subjective tests were conducted to determine the ease with which subjects could identify the direction of the movement of the source in rooms with varying amounts of absorption. This method can be used to create more realistic classroom auralizations, as teachers typically move around the room as they teach. [Work supported by the National Science Foundation.

  4. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  5. Hyperbolic Positioning with Antenna Arrays and Multi-Channel Pseudolite for Indoor Localization

    Directory of Open Access Journals (Sweden)

    Kenjirou Fujii

    2015-09-01

    Full Text Available A hyperbolic positioning method with antenna arrays consisting of proximately-located antennas and a multi-channel pseudolite is proposed in order to overcome the problems of indoor positioning with conventional pseudolites (ground-based GPS transmitters. A two-dimensional positioning experiment using actual devices is conducted. The experimental result shows that the positioning accuracy varies centimeter- to meter-level according to the geometric relation between the pseudolite antennas and the receiver. It also shows that the bias error of the carrier-phase difference observables is more serious than their random error. Based on the size of the bias error of carrier-phase difference that is inverse-calculated from the experimental result, three-dimensional positioning performance is evaluated by computer simulation. In addition, in the three-dimensional positioning scenario, an initial value convergence analysis of the non-linear least squares is conducted. Its result shows that initial values that can converge to a right position exist at least under the proposed antenna setup. The simulated values and evaluation methods introduced in this work can be applied to various antenna setups; therefore, by using them, positioning performance can be predicted in advance of installing an actual system.

  6. Reprocessing of multi-channel seismic-reflection data collected in the Beaufort Sea

    Science.gov (United States)

    Agena, W.F.; Lee, Myung W.; Hart, P.E.

    2000-01-01

    Contained on this set of two CD-ROMs are stacked and migrated multi-channel seismic-reflection data for 65 lines recorded in the Beaufort Sea by the United States Geological Survey in 1977. All data were reprocessed by the USGS using updated processing methods resulting in improved interpretability. Each of the two CD-ROMs contains the following files: 1) 65 files containing the digital seismic data in standard, SEG-Y format; 2) 1 file containing navigation data for the 65 lines in standard SEG-P1 format; 3) an ASCII text file with cross-reference information for relating the sequential trace numbers on each line to cdp numbers and shotpoint numbers; 4) 2 small scale graphic images (stacked and migrated) of a segment of line 722 in Adobe Acrobat (R) PDF format; 5) a graphic image of the location map, generated from the navigation file; 6) PlotSeis, an MS-DOS Application that allows PC users to interactively view the SEG-Y files; 7) a PlotSeis documentation file; and 8) an explanation of the processing used to create the final seismic sections (this document).

  7. Multi-Channel RF System for MRI-Guided Transurethral Ultrasound Thermal Therapy

    Science.gov (United States)

    Yak, Nicolas; Asselin, Matthew; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound thermal therapy is an approach to treating localized prostate cancer which targets precise deposition of thermal energy within a confined region of the gland. This treatment requires a system incorporating a heating applicator with multiple planar ultrasound transducers and associated RF electronics to control individual elements independently in order to achieve accurate 3D treatment. We report the design, construction, and characterization of a prototype multi-channel system capable of controlling 16 independent RF signals for a 16-element heating applicator. The main components are a control computer, microcontroller, and a 16-channel signal generator with 16 amplifiers, each incorporating a low-pass filter and transmitted/reflected power detection circuit. Each channel can deliver from 0.5 to 10 W of electrical power and good linearity from 3 to 12 MHz. Harmonic RF signals near the Larmor frequency of a 1.5 T MRI were measured to be below -30 dBm and heating experiments within the 1.5 T MR system showed no significant decrease in SNR of the temperature images. The frequency and power for all 16 channels could be changed in less than 250 ms, which was sufficiently rapid for proper performance of the control algorithms. A common backplane design was chosen which enabled an inexpensive, modular approach for each channel resulting in an overall system with minimal footprint.

  8. A multi-channel magnetic induction tomography measurement system for human brain model imaging

    International Nuclear Information System (INIS)

    Xu, Zheng; Luo, Haijun; He, Wei; He, Chuanhong; Song, Xiaodong; Zahng, Zhanglong

    2009-01-01

    This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in a human brain model. A hemispherical glass bowl filled with a salt solution is used as the human brain model; meanwhile, agar blocks of different conductivity are placed in the solution to simulate the intracerebral hemorrhage. The excitation and detection coils are fixed co-axially, and the axial gradiometer is used as the detection coil in order to cancel the primary field. On the outer surface of the glass bowl, 15 sensor units are arrayed in two circles as measurement parts, and a single sensor unit for canceling the phase drift is placed beside the glass bowl. The phase sensitivity of our system is 0.204°/S m −1 with the excitation frequency of 120 kHz and the phase noise is in the range of −0.03° to +0.05°. Only the coaxial detection coil is available for each excitation coil; therefore, 15 phase data are collected in each measurement turn. Finally, the two-dimensional images of conductivity distribution are obtained using an interpolation algorithm. The frequency-varying experiment indicates that the imaging quality becomes better as the excitation frequency is increased

  9. Automated Filtering of Common Mode Artifacts in Multi-Channel Physiological Recordings

    Science.gov (United States)

    Kelly, John W.; Siewiorek, Daniel P.; Smailagic, Asim; Wang, Wei

    2014-01-01

    The removal of spatially correlated noise is an important step in processing multi-channel recordings. Here, a technique termed the adaptive common average reference (ACAR) is presented as an effective and simple method for removing this noise. The ACAR is based on a combination of the well-known common average reference (CAR) and an adaptive noise canceling (ANC) filter. In a convergent process, the CAR provides a reference to an ANC filter, which in turn provides feedback to enhance the CAR. This method was effective on both simulated and real data, outperforming the standard CAR when the amplitude or polarity of the noise changes across channels. In many cases the ACAR even outperformed independent component analysis (ICA). On 16 channels of simulated data the ACAR was able to attenuate up to approximately 290 dB of noise and could improve signal quality if the original SNR was as high as 5 dB. With an original SNR of 0 dB, the ACAR improved signal quality with only two data channels and performance improved as the number of channels increased. It also performed well under many different conditions for the structure of the noise and signals. Analysis of contaminated electrocorticographic (ECoG) recordings further showed the effectiveness of the ACAR. PMID:23708770

  10. Multi-channel Spiral Twist Extrusion (MCSTE): A Novel Severe Plastic Deformation Technique for Grain Refinement

    Science.gov (United States)

    El-Garaihy, W. H.; Fouad, D. M.; Salem, H. G.

    2018-04-01

    Multi-channel Spiral Twist Extrusion (MCSTE) is introduced as a novel severe plastic deformation (SPD) technique for producing superior mechanical properties associated with ultrafine grained structure in bulk metals and alloys. The MCSTE design is based on inserting a uniform square cross-sectioned billet within stacked disks that guarantee shear strain accumulation. In an attempt to validate the technique and evaluate its plastic deformation characteristics, a series of experiments were conducted. The influence of the number of MCSTE passes on the mechanical properties and microstructural evolution of AA1100 alloy were investigated. Four passes of MCSTE, at a relatively low twisting angle of 30 deg, resulted in increasing the strength and hardness coupled with retention of ductility. Metallographic observations indicated a significant grain size reduction of 72 pct after 4 passes of MCSTE compared with the as-received (AR) condition. Moreover, the structural uniformity increased with the number of passes, which was reflected in the hardness distribution from the peripheries to the center of the extrudates. The current study showed that the MCSTE technique could be an effective, adaptable SPD die design with a promising potential for industrial applications compared to its counterparts.

  11. The Over-Barrier Resonant States and Multi-Channel Scattering in Multiple Quantum Wells

    Directory of Open Access Journals (Sweden)

    A Polupanov

    2016-09-01

    Full Text Available We demonstrate an explicit numerical method for accurate calculation of the scattering matrix and its poles, and apply this method to describe the multi-channel scattering in the multiple quantum-wells structures. The S-matrix is continued analytically to the unphysical region of complex energy values. Results of calculations show that there exist one or more S-matrix poles, corresponding to the over-barrier resonant states critical for the effect of the absolute reflection of holes in the energy range where only the heavy ones may propagate over barriers in a structure. Light- and heavy-hole states are described by the Luttinger Hamiltonian matrix. In contrast to the single quantum-well case, at some parameters of a multiple quantum-wells structure the number of S-matrix poles may exceed that of the absolute reflection peaks, and at different values of parameters the absolute reflection peak corresponds to different resonant states. The imaginary parts of the S-matrix poles and hence the lifetimes of resonant states as well as the widths of resonant peaks of absolute reflection depend drastically on the quantum-well potential depth. In the case of shallow quantum wells there is in fact a long-living over-barrier resonant hole state.

  12. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Chau, A.; DeBusschere, D.; Dow, S.F.; Flasck, J.; Levi, M.E.; Kirsten, F.; Su, E.; Santos, D.M.

    1996-01-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e., 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using an TDC comprised of a delay locked loop, latch and encoder. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. Eight complete channels of timing and amplitude information are multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are subsequently transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in an 0.8 microm triple metal CMOS process. The measured results indicate that the differential non-linearities of the TDC and the FADC are 200 ps and 10 mV, respectively. The integral nonlinearities of the TDC and the FADC are 230 ps and 9 mV, respectively

  13. Development of a Multi-Channel Piezoelectric Acoustic Sensor Based on an Artificial Basilar Membrane

    Directory of Open Access Journals (Sweden)

    Youngdo Jung

    2013-12-01

    Full Text Available In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies. The length of the membrane is 28 mm and the width of the membrane varies from 1 mm to 8 mm. Multiphysics finite element analysis (FEA was carried out to predict and design the mechanical behaviors and piezoelectric response of the McPAS model. The designed McPAS was fabricated with a MEMS fabrication process based on the simulated results. The fabricated device was tested with a mouth simulator to measure its mechanical and piezoelectrical frequency response with a laser Doppler vibrometer and acoustic signal analyzer. The experimental results show that the as fabricated McPAS can successfully separate incoming acoustic signals within the 2.5 kHz–13.5 kHz range and the maximum electrical signal output upon acoustic signal input of 94 dBSPL was 6.33 mVpp. The performance of the fabricated McPAS coincided well with the designed parameters.

  14. A wireless multi-channel recording system for freely behaving mice and rats.

    Science.gov (United States)

    Fan, David; Rich, Dylan; Holtzman, Tahl; Ruther, Patrick; Dalley, Jeffrey W; Lopez, Alberto; Rossi, Mark A; Barter, Joseph W; Salas-Meza, Daniel; Herwik, Stanislav; Holzhammer, Tobias; Morizio, James; Yin, Henry H

    2011-01-01

    To understand the neural basis of behavior, it is necessary to record brain activity in freely moving animals. Advances in implantable multi-electrode array technology have enabled researchers to record the activity of neuronal ensembles from multiple brain regions. The full potential of this approach is currently limited by reliance on cable tethers, with bundles of wires connecting the implanted electrodes to the data acquisition system while impeding the natural behavior of the animal. To overcome these limitations, here we introduce a multi-channel wireless headstage system designed for small animals such as rats and mice. A variety of single unit and local field potential signals were recorded from the dorsal striatum and substantia nigra in mice and the ventral striatum and prefrontal cortex simultaneously in rats. This wireless system could be interfaced with commercially available data acquisition systems, and the signals obtained were comparable in quality to those acquired using cable tethers. On account of its small size, light weight, and rechargeable battery, this wireless headstage system is suitable for studying the neural basis of natural behavior, eliminating the need for wires, commutators, and other limitations associated with traditional tethered recording systems.

  15. A wireless multi-channel recording system for freely behaving mice and rats.

    Directory of Open Access Journals (Sweden)

    David Fan

    Full Text Available To understand the neural basis of behavior, it is necessary to record brain activity in freely moving animals. Advances in implantable multi-electrode array technology have enabled researchers to record the activity of neuronal ensembles from multiple brain regions. The full potential of this approach is currently limited by reliance on cable tethers, with bundles of wires connecting the implanted electrodes to the data acquisition system while impeding the natural behavior of the animal. To overcome these limitations, here we introduce a multi-channel wireless headstage system designed for small animals such as rats and mice. A variety of single unit and local field potential signals were recorded from the dorsal striatum and substantia nigra in mice and the ventral striatum and prefrontal cortex simultaneously in rats. This wireless system could be interfaced with commercially available data acquisition systems, and the signals obtained were comparable in quality to those acquired using cable tethers. On account of its small size, light weight, and rechargeable battery, this wireless headstage system is suitable for studying the neural basis of natural behavior, eliminating the need for wires, commutators, and other limitations associated with traditional tethered recording systems.

  16. The development of a digital multi-channel pulse height analysis

    International Nuclear Information System (INIS)

    Huang Shanshan; Sang Ziru; Liang Futian; Chen Lian; Liang Hao; Jin Ge

    2012-01-01

    A kind of digital multi-channel analyzer which was developed for Nuclear and Particle Experiment of Undergraduate Student in university was introduced. The input signal is digitalized with a high speed ADC, and feed to a FPGA for seeking peak, recording, spectrometer processing and displaying automatically. The principle of digital searching peck was given in the paper. In order to improve the capability of anti-noise, a dual digital thresholds and dual buffer memories was designed. Aiming at the influence of nonlinear of ADC to the system, a revised algorithm was designed to ensure the channel width uniformity. Since the huge sampling and storaging data of MCA, a method of parallel work of double memory was used, just separated empty transmit data and stored count, reduced the dead time and data overflowing. The host computer can set up and monitor MCA real-time, read and write data from MCA by an USB interface. Contrasts commercial MCA, the MCA has a good result in function and price. (authors)

  17. Binaural unmasking of multi-channel stimuli in bilateral cochlear implant users.

    Science.gov (United States)

    Van Deun, Lieselot; van Wieringen, Astrid; Francart, Tom; Büchner, Andreas; Lenarz, Thomas; Wouters, Jan

    2011-10-01

    Previous work suggests that bilateral cochlear implant users are sensitive to interaural cues if experimental speech processors are used to preserve accurate interaural information in the electrical stimulation pattern. Binaural unmasking occurs in adults and children when an interaural delay is applied to the envelope of a high-rate pulse train. Nevertheless, for speech perception, binaural unmasking benefits have not been demonstrated consistently, even with coordinated stimulation at both ears. The present study aimed at bridging the gap between basic psychophysical performance on binaural signal detection tasks on the one hand and binaural perception of speech in noise on the other hand. Therefore, binaural signal detection was expanded to multi-channel stimulation and biologically relevant interaural delays. A harmonic complex, consisting of three sinusoids (125, 250, and 375 Hz), was added to three 125-Hz-wide noise bands centered on the sinusoids. When an interaural delay of 700 μs was introduced, an average BMLD of 3 dB was established. Outcomes are promising in view of real-life benefits. Future research should investigate the generalization of the observed benefits for signal detection to speech perception in everyday listening situations and determine the importance of coordination of bilateral speech processors and accentuation of envelope cues.

  18. Theoretical Valuation of Multi-Channel Cyclone to Reduce Gas Flow Dustiness in Agressive Environment

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2016-10-01

    Full Text Available Contaminated gas cleaning from finely divided solids is carried out using a new generation of multi-channel design cyclones. The application of these devices are separated and precipitated particles with a minimum diameter up to 2 micrometers, reaching up to 95% cleaning efficiency. Cyclones of such constructions are usually used under usual conditions at elevated temperature and low humidity. Under aggressive conditions, these devices can be clogged, and their recovery is not possible. Further studies are research into the application of constructive solutions to adapt the cyclone gas cleaning of the particulate matter under aggressive conditions. This theoretical evaluation has described the characteristics change of gas flow and particulate matters at different aggressive environment. Such conditions were loudly describe the gas-flow high-temperature range of 50–200 °C and gas-vapor stream, the humidity reaches 70–100%. Estimated aggressive conditions on the gas flow dynamics forces – pressure, resistance and centrifugal, and particulate mechanical – gravitational and adhesion strength. All parameters are evaluated in comparison with the values under normal conditions.

  19. Centralized Routing and Scheduling Using Multi-Channel System Single Transceiver in 802.16d

    Science.gov (United States)

    Al-Hemyari, A.; Noordin, N. K.; Ng, Chee Kyun; Ismail, A.; Khatun, S.

    This paper proposes a cross-layer optimized strategy that reduces the effect of interferences from neighboring nodes within a mesh networks. This cross-layer design relies on the routing information in network layer and the scheduling table in medium access control (MAC) layer. A proposed routing algorithm in network layer is exploited to find the best route for all subscriber stations (SS). Also, a proposed centralized scheduling algorithm in MAC layer is exploited to assign a time slot for each possible node transmission. The cross-layer optimized strategy is using multi-channel single transceiver and single channel single transceiver systems for WiMAX mesh networks (WMNs). Each node in WMN has a transceiver that can be tuned to any available channel for eliminating the secondary interference. Among the considered parameters in the performance analysis are interference from the neighboring nodes, hop count to the base station (BS), number of children per node, slot reuse, load balancing, quality of services (QoS), and node identifier (ID). Results show that the proposed algorithms significantly improve the system performance in terms of length of scheduling, channel utilization ratio (CUR), system throughput, and average end to end transmission delay.

  20. Multi-channel data acquisition and processing system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Jin Ge; Yang Yanming

    1987-01-01

    A multi-channel data acquisition and processing system for moessbauer spectroscopy is described, which consists of an intelligent interface and a BC3-80 microcomputer. The system has eight data channels, each channel contains a counting circuit and a memory. A Z80-CPU is used as a main unit for control and access. The microcomputer is used for real-time displaying spectrum, saving the data to disk, printing data and data processing. The system is applicable to a high counting rate multi-wire proportional chamber. It can increase greatly the counting rate for measuring moessbauer spectrum. The signals of each wire in the chamber go through a corresponding amplifier and a differential discriminator and are recorded by a corresponding data channel, the data of each channel is added by the microcomputer. In addition, two channels can be used to measure an absorption and a scattering spectrum at the same time and the internal and the surface information of the sample are obtained simultaneously

  1. Super-pixel extraction based on multi-channel pulse coupled neural network

    Science.gov (United States)

    Xu, GuangZhu; Hu, Song; Zhang, Liu; Zhao, JingJing; Fu, YunXia; Lei, BangJun

    2018-04-01

    Super-pixel extraction techniques group pixels to form over-segmented image blocks according to the similarity among pixels. Compared with the traditional pixel-based methods, the image descripting method based on super-pixel has advantages of less calculation, being easy to perceive, and has been widely used in image processing and computer vision applications. Pulse coupled neural network (PCNN) is a biologically inspired model, which stems from the phenomenon of synchronous pulse release in the visual cortex of cats. Each PCNN neuron can correspond to a pixel of an input image, and the dynamic firing pattern of each neuron contains both the pixel feature information and its context spatial structural information. In this paper, a new color super-pixel extraction algorithm based on multi-channel pulse coupled neural network (MPCNN) was proposed. The algorithm adopted the block dividing idea of SLIC algorithm, and the image was divided into blocks with same size first. Then, for each image block, the adjacent pixels of each seed with similar color were classified as a group, named a super-pixel. At last, post-processing was adopted for those pixels or pixel blocks which had not been grouped. Experiments show that the proposed method can adjust the number of superpixel and segmentation precision by setting parameters, and has good potential for super-pixel extraction.

  2. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  3. A strategy for determination of test intervals of k-out-of-n multi-channel systems

    International Nuclear Information System (INIS)

    Cho, S.; Jiang, J.

    2007-01-01

    State space models for determination of the optimal test frequencies for k-out-of-n multi channel systems are developed in this paper. The analytic solutions for the optimal surveillance test frequencies are derived using the Markov process technique. The solutions show that an optimal test frequency which maximizes the target probability can be determined by decomposing the system states to 3 states based on the system configuration and success criteria. Examples of quantification of the state probabilities and the optimal test frequencies of a three-channel system and a four-channel system with different success criteria are presented. The strategy for finding the optimal test frequency developed in this paper can generally be applicable to any k-out-of-n multi-channel standby systems that involve complex testing schemes. (author)

  4. Operational Criteria for the Design of Front-Office Processes in Multi-Channel Service Delivery Systems

    OpenAIRE

    Sousa, Rui; Amorim, Marlene

    2010-01-01

    This paper identifies relevant operational factors that affect the design of front-office processes in Multi-Channel Service Delivery Systems. Based on two in-depth case studies in banking and telecommunications, we distinguish four operational factors: i) characteristics of the inputs and outputs of the service activities; ii) characteristics of the transformation taking place; iii) the expected utilization; iv) the economics of developing the activities in the channels. Building on these re...

  5. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI.

    Science.gov (United States)

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, Michal; Standara, Michal; Starčuk, Zenon; Taxt, Torfinn

    2016-03-01

    One of the main challenges in quantitative dynamic contrast-enhanced (DCE) MRI is estimation of the arterial input function (AIF). Usually, the signal from a single artery (ignoring contrast dispersion, partial volume effects and flow artifacts) or a population average of such signals (also ignoring variability between patients) is used. Multi-channel blind deconvolution is an alternative approach avoiding most of these problems. The AIF is estimated directly from the measured tracer concentration curves in several tissues. This contribution extends the published methods of multi-channel blind deconvolution by applying a more realistic model of the impulse residue function, the distributed capillary adiabatic tissue homogeneity model (DCATH). In addition, an alternative AIF model is used and several AIF-scaling methods are tested. The proposed method is evaluated on synthetic data with respect to the number of tissue regions and to the signal-to-noise ratio. Evaluation on clinical data (renal cell carcinoma patients before and after the beginning of the treatment) gave consistent results. An initial evaluation on clinical data indicates more reliable and less noise sensitive perfusion parameter estimates. Blind multi-channel deconvolution using the DCATH model might be a method of choice for AIF estimation in a clinical setup. © 2015 Wiley Periodicals, Inc.

  6. Experimental researches and comparison on aerodynamic parameters and cleaning efficiency of multi-level multi-channel cyclone

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2015-10-01

    Full Text Available Multi-level multi-channel cyclone – the lately designed air cleaning device that can remove ultra-fine 20 μm particulatematter (PM from dusted air and reach over 95% of the overall cleaning efficiency. Multi-channel cyclone technology is based on centrifugal forces and has the resulting additional filtering process operation. Multi-level structure of cyclone allows to achieve higher air flow cleaning capacity at the same dimensions of the device, thus saving installation space required for the job, production and operating costs. Studies have examined the air flow parameters change in one–, two– and three–levels multichannel cyclone. These constructions differ according to the productivity of cleaned air under the constant peripheral and transitional (50/50 case air flow relations. Accordance with the results of air flow dynamics – velocity distribution of multi-channel cyclone, aerodynamic resistance and efficiency can be judged on the flow turbulence, the flow channel cross-section and select the most appropriate application. Cleaning efficiency studies were carried out using fine granite and wood ashes PM. The maximum cleaning efficiency was 93.3%, at an average of 4.5 g/m3, the aerodynamic resistance was equal to 1525 Pa.

  7. Development of multi-channel optical-fiber feed through for ITER

    International Nuclear Information System (INIS)

    Sugie, Tatsuo; Kasai, Satoshi; Toriya, Tomoaki

    1998-08-01

    A multi-channel fiber feed through has been developed for visible and IR transmission lines through secondary vacuum boundary (cryostat boundary) of ITER. In the first phase, a scale down test-module which has ten fiber feed through in the vacuum flange was manufactured and tested. The vacuum seal was realized by soldering gold plated fibers to a vacuum flange with high temperature solder. The capacity to resist inner pressure rise of 5 atm, the acceleration resistant of 15g and the temperature resistant from 20degC-200degC were achieved by the test module. The connecting loss and the uniformity of transmission losses among each channels of the feed through were not well. Concerning the connecting loss, the best value was 2.2 dB and the worst one was 13.5 dB. In the second phase, the full performance test-module which has 57 fiber feed through was manufactured and tested. The feed through was improved in order to achieve a good transmission and the uniformity among each channels by using a optical fiber implanted in a center of a quartz rod very accurately. The capacity to resist inner pressure rise of 5 atm, the acceleration resistant of 15g and the temperature resistant from 40degC-200degC (Temperature ramp rate: >20degC/hr) were achieved by the full performance test-module. The connecting losses of the feed through were less than 3 dB, and the uniformity of transmission losses among each channels of the feed through was larger than 60%. The requirements for an optical-fiber feed through were almost satisfied with the full performance test-module. Further developments will be necessary for the remote handling method. (author)

  8. Time-varying bispectral analysis of visually evoked multi-channel EEG

    Science.gov (United States)

    Chandran, Vinod

    2012-12-01

    Theoretical foundations of higher order spectral analysis are revisited to examine the use of time-varying bicoherence on non-stationary signals using a classical short-time Fourier approach. A methodology is developed to apply this to evoked EEG responses where a stimulus-locked time reference is available. Short-time windowed ensembles of the response at the same offset from the reference are considered as ergodic cyclostationary processes within a non-stationary random process. Bicoherence can be estimated reliably with known levels at which it is significantly different from zero and can be tracked as a function of offset from the stimulus. When this methodology is applied to multi-channel EEG, it is possible to obtain information about phase synchronization at different regions of the brain as the neural response develops. The methodology is applied to analyze evoked EEG response to flash visual stimulii to the left and right eye separately. The EEG electrode array is segmented based on bicoherence evolution with time using the mean absolute difference as a measure of dissimilarity. Segment maps confirm the importance of the occipital region in visual processing and demonstrate a link between the frontal and occipital regions during the response. Maps are constructed using bicoherence at bifrequencies that include the alpha band frequency of 8Hz as well as 4 and 20Hz. Differences are observed between responses from the left eye and the right eye, and also between subjects. The methodology shows potential as a neurological functional imaging technique that can be further developed for diagnosis and monitoring using scalp EEG which is less invasive and less expensive than magnetic resonance imaging.

  9. Take time to make time : What to consider when managing multi-channel sales systems with the objective to increase sales efficiency

    OpenAIRE

    ALM, RAGNAR; KYRÖNLAHTI, RUDY

    2016-01-01

    Traditional sales systems have been disrupted by technological developments. In order to  adapt, companies are changing the way they interact with their customers in business-to-business markets. In the last three decades, multi-channel strategies have spurred the proliferation of different sales channels and new ways of managing sales systems. The purpose of this research was to investigate what should be considered when managing multi-channel sales systems with the objective of increasing s...

  10. Multi-channel programmable power supply with temperature compensation for silicon sensors

    International Nuclear Information System (INIS)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R.; Kurup, A. M.; Lokhandwala, S. S.; Prabhu, S. S.; Freeman, J.; Los, S.; Garde, C. S.; Khandekar, P. D.; Gupta, S. K.; Rakshe, P. S.

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  11. Seismarmara experiment: results from reprocessing of selected multi-channel seismic reflection profiles

    Science.gov (United States)

    Cetin, S.; Voogd, B.; Carton, H.; Laigle, M.; Becel, A.; Saatcilar, R.; Singh, S.; Hirn, A.

    2003-04-01

    The North Anatolian Fault (NAF) has been responsible for the earthquakes of Izmit and Duzce in 1999. The occurrence of these earthquakes has drawn scientific attention into the Sea of Marmara since the NAF enters into the Sea of Marmara where the latest Izmit earthquake rupture stopped. The SEISMARMARA-2001 survey is a combined seismic reflection, refraction and earthquake experiment carried out in 2001 in the Marmara Region in Turkey by French-Turkish scientific cooperation. The objectives of this survey were to image the various branches of the NAF and related other fault systems. R/V Le Nadir was equipped with a 4.5 km long streamer with 360 channels and a large airgun source. During Leg 1, a grid of large regional lines encompassing the whole Marmara trough was shot. For part of them a strong 8100 cu.in. source for deepest penetration was used, with a 150 m shot interval giving a 15-fold coverage. Another part was shot for a higher resolution with a 2900 cu. in. array at a 50m or 38 m interval to give a 45 or 60-fold coverage. The latter acquisition parameters were used for Leg 2 that was devoted to a very dense grid of lines in the Cinarcik Basin Reprocessing of the multi-channel seismic data is currently being undertaken in several Institutions using different seismic processing softwares (GeoVecteur, ProMAX, Focus), to take advantage of the diverse acquisitions and cope with their limitations, for instance high fold-order for Leg 2 and strength of signal but loose spatial sampling for the bigger source. The main objectives of the reprocessing of the selected profiles are to do a detailed velocity analysis and stacking after deconvolution, filtering to remove or suppress deep sea bottom multiples and out of plane reflections, and time-migration and depth conversion and thus reveal both the shallow and deeper reflection image of the crust in the Sea of Marmara. We show that choosing an appropriate processing sequence for different sources and acquisition

  12. Multi-channel programmable power supply with temperature compensation for silicon sensors

    Energy Technology Data Exchange (ETDEWEB)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R., E-mail: dugad@cern.ch; Kurup, A. M.; Lokhandwala, S. S.; Prabhu, S. S. [Tata Institute of Fundamental Research, Mumbai 400005 (India); Freeman, J.; Los, S. [Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States); Garde, C. S.; Khandekar, P. D. [Vishwakarma Institute of Information Technology, Pune 411048 (India); Gupta, S. K. [Tata Institute of Fundamental Research, Mumbai 400005 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India); Rakshe, P. S. [Vishwakarma Institute of Information Technology, Pune 411048 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India)

    2016-01-15

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  13. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Guangkai [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China and Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Wu, Guorong [Department of Computer Science, Department of Radiology, and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Wu, Ligang [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001 (China); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2016-02-15

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  14. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    International Nuclear Information System (INIS)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-01-01

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  15. Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

    Science.gov (United States)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-02-01

    It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient

  16. Multi-channel EEG-based sleep stage classification with joint collaborative representation and multiple kernel learning.

    Science.gov (United States)

    Shi, Jun; Liu, Xiao; Li, Yan; Zhang, Qi; Li, Yingjie; Ying, Shihui

    2015-10-30

    Electroencephalography (EEG) based sleep staging is commonly used in clinical routine. Feature extraction and representation plays a crucial role in EEG-based automatic classification of sleep stages. Sparse representation (SR) is a state-of-the-art unsupervised feature learning method suitable for EEG feature representation. Collaborative representation (CR) is an effective data coding method used as a classifier. Here we use CR as a data representation method to learn features from the EEG signal. A joint collaboration model is established to develop a multi-view learning algorithm, and generate joint CR (JCR) codes to fuse and represent multi-channel EEG signals. A two-stage multi-view learning-based sleep staging framework is then constructed, in which JCR and joint sparse representation (JSR) algorithms first fuse and learning the feature representation from multi-channel EEG signals, respectively. Multi-view JCR and JSR features are then integrated and sleep stages recognized by a multiple kernel extreme learning machine (MK-ELM) algorithm with grid search. The proposed two-stage multi-view learning algorithm achieves superior performance for sleep staging. With a K-means clustering based dictionary, the mean classification accuracy, sensitivity and specificity are 81.10 ± 0.15%, 71.42 ± 0.66% and 94.57 ± 0.07%, respectively; while with the dictionary learned using the submodular optimization method, they are 80.29 ± 0.22%, 71.26 ± 0.78% and 94.38 ± 0.10%, respectively. The two-stage multi-view learning based sleep staging framework outperforms all other classification methods compared in this work, while JCR is superior to JSR. The proposed multi-view learning framework has the potential for sleep staging based on multi-channel or multi-modality polysomnography signals. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. ON SCALAR MESONS FROM THE COMBINED ANALYSIS OF MULTI-CHANNEL pi pi SCATTERING AND J/psi DECAYS

    Czech Academy of Sciences Publication Activity Database

    Surovtsev, Yu .S.; Bydžovský, Petr; Gutsche, T.; Lyubovitskij, V. E.

    2011-01-01

    Roč. 26, 3-4 (2011), s. 610-612 ISSN 0217-751X. [11th International Workshop on Meson Production , Properties and Interaction. Krakow, 10.06.2010-15.06.2010] R&D Projects: GA ČR GA202/08/0984 Institutional research plan: CEZ:AV0Z10480505 Keywords : Multi-channel pion-pion scattering * scalar-isoscalar resonances * multichannel analysis Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.053, year: 2011

  18. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...

  19. Joint image reconstruction method with correlative multi-channel prior for x-ray spectral computed tomography

    DEFF Research Database (Denmark)

    Kazantsev, Daniil; Jørgensen, Jakob Sauer; Andersen, Martin S

    2018-01-01

    peaks. The acquired energy-binned data, however, suffer from low signal-to-noise ratio, acquisition artifacts, and frequently angular undersampled conditions. New regularized iterative reconstruction methods have the potential to produce higher quality images and since energy channels are mutually...... to encourage joint smoothing directions. In particular, the method selects reference channels from which to propagate structure in an adaptive and stochastic way while preferring channels with a high data signal-to-noise ratio. The method is compared with current state-of-the-art multi-channel reconstruction...

  20. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI

    Czech Academy of Sciences Publication Activity Database

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, M.; Standara, M.; Starčuk jr., Zenon; Taxt, T.

    2016-01-01

    Roč. 75, č. 3 (2016), s. 1355-1365 ISSN 0740-3194 R&D Projects: GA ČR GAP102/12/2380; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : dynamic contrast-enhanced magnetic resonance imaging * multi-channel blind deconvolution * arterial input function * impulse residue function * renal cell carcinoma Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.924, year: 2016

  1. Multi-channel control circuit for real-time control of events in Aditya tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Edappala, Praveenlal, E-mail: praveen@ipr.res.in; Shah, Minsha; Rajpal, Rachana; Tanna, R.L.; Ghosh, Joydeep; Chattopadhyay, P.K.; Jha, R.

    2016-11-15

    Highlights: • Low cost microcontroller based control circuit. • The control hardware can be programmed/configured very easily for different applications. • Microcontroller programming is done in assembly language so that precise timing can be achieved with micro seconds resolution. • Successful implementation of this circuit in noisy tokamak environment. • Efficient noise and burst elimination. • Can be integrated in to the other subsystems. • Low cost solution for implementing feedback control in small and medium size tokamaks and other experiments requiring feedback control. - Abstract: Tokamak plasma is prone to many random events having potential for causing severe damages to the machine, such as disruptions, production and elimination of high-energy runaway electrons etc. These events can be mitigated by obtaining pre-cursor signal leading to these events and then taking proper measures just before their onset to avoid their happenings, like disruptions can be mitigated by massive gas injection or putting a bias voltage on an electrode placed inside the plasma, the runaways can be mitigated by gas injection and by applying specific magnetic fields. Hence for real time control of these events, the pre-cursors should be electronically recorded and the mitigation techniques should be initiated by sending triggers to their individual operational systems. To implement these methodologies of real-time controlling of events in Aditya Tokamak, a low cost multi-channel Micro-Controller based timing circuit is designed and developed in-house. This circuit first compares the precursor signals fed into it with the pre-set values and gives a trigger output whenever the signals overshoot the pre-set values. The circuit readies itself for operation along with start of the tokamak discharge and waits up to an initial pre-determined delay and then initiates a trigger at the time of overshooting of precursor signal. The circuit is fully integrated and assembled in

  2. Childhood body mass index and risk of adult pancreatic cancer

    DEFF Research Database (Denmark)

    Nogueira, Leticia; Stolzenberg-Solomon, Rachael; Gamborg, Michael

    2017-01-01

    incident pancreatic cancer cases from 1968-2012. Hazard ratios (HR) and 95% confidence intervals (CI) were estimated using Cox proportional hazard regressions. Results: During 8,207,015 person-years of follow-up, 1,268 pancreatic cancer cases were diagnosed. Childhood BMI z-scores at ages 7-13 years were......Background: Excess weight in adulthood is one of the few modifiable risk factors for pancreatic cancer, and height has associations as well. This leads to question whether body weight and height in childhood are associated with adult pancreatic cancer. Objective: To examine if childhood body mass...... from 7-13 years is positively and linearly associated with adult pancreatic cancer; the higher the BMI, the higher the risk. Excess childhood BMI may be indicative of processes initiated early in life that lead to this cancer. Prevention of childhood adiposity may decrease the burden of pancreatic...

  3. Development of multi-channel high power rectangular RF window for LHCD system employing high temperature vacuum brazing technique

    International Nuclear Information System (INIS)

    Sharma, P K; Ambulkar, K K; Parmar, P R; Virani, C G; Thakur, A L; Joshi, L M; Nangru, S C

    2010-01-01

    A 3.7 GHz., 120 kW (pulsed), lower hybrid current drive (LHCD) system is employed to drive non-inductive plasma current in ADITYA tokamak. The rf power is coupled to the plasma through grill antenna and is placed in vacuum environment. A vacuum break between the pressurized transmission line and the grill antenna is achieved with the help of a multi (eight) channel rectangular RF vacuum window. The phasing between adjacent channels of 8-channel window (arranged in two rows) is important for launching lower hybrid waves and each channel should have independent vacuum window so that phase information is retained. The geometrical parameter of the grill antenna, like periodicity (9mm), channel dimensions (cross sectional dimension of 76mm x 7mm), etc. is to be maintained. These design constraint demanded a development of a multi channel rectangular RF vacuum window. To handle rf losses and thermal effects, high temperature vacuum brazing techniques is desired. Based on the above requirements we have successfully developed a multi channel rectangular rf vacuum window employing high temperature vacuum brazing technique. During the development process we could optimize the chemical processing parameters, brazing process parameters, jigs and fixtures for high temperature brazing and leak testing, etc. Finally the window is tested for low power rf performance using VNA. In this paper we would present the development of the said window in detail along with its mechanical, vacuum and rf performances.

  4. Development of multi-channel high power rectangular RF window for LHCD system employing high temperature vacuum brazing technique

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, P K; Ambulkar, K K; Parmar, P R; Virani, C G; Thakur, A L [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India); Joshi, L M; Nangru, S C, E-mail: pramod@ipr.res.i [Central Electronics Engineering Research Institute, Pilani, Rajasthan 333 031 (India)

    2010-02-01

    A 3.7 GHz., 120 kW (pulsed), lower hybrid current drive (LHCD) system is employed to drive non-inductive plasma current in ADITYA tokamak. The rf power is coupled to the plasma through grill antenna and is placed in vacuum environment. A vacuum break between the pressurized transmission line and the grill antenna is achieved with the help of a multi (eight) channel rectangular RF vacuum window. The phasing between adjacent channels of 8-channel window (arranged in two rows) is important for launching lower hybrid waves and each channel should have independent vacuum window so that phase information is retained. The geometrical parameter of the grill antenna, like periodicity (9mm), channel dimensions (cross sectional dimension of 76mm x 7mm), etc. is to be maintained. These design constraint demanded a development of a multi channel rectangular RF vacuum window. To handle rf losses and thermal effects, high temperature vacuum brazing techniques is desired. Based on the above requirements we have successfully developed a multi channel rectangular rf vacuum window employing high temperature vacuum brazing technique. During the development process we could optimize the chemical processing parameters, brazing process parameters, jigs and fixtures for high temperature brazing and leak testing, etc. Finally the window is tested for low power rf performance using VNA. In this paper we would present the development of the said window in detail along with its mechanical, vacuum and rf performances.

  5. Evaluation of K x-ray escape and crosstalk in CdTe detectors and multi-channel detectors

    International Nuclear Information System (INIS)

    Ohtsuchi, Tetsuro; Ohmori, Koichi; Tsutsui, Hiroshi; Baba, Sueki

    1995-01-01

    The simple structure of CdTe semiconductor detectors facilitates their downsizing, and their possible application to radiographic sensors has been studied. The escape of K X-rays from these detectors increases with reduction of their dimensions and affects the measurements of X- and gamma-ray spectra. K X-rays also produce crosstalk in multi-channel detectors with adjacent channels. Therefore, K X-rays which escape from the detector elements degrade both the precision of energy spectra and spatial resolution. The ratios of escape peak integrated counts to total photon counts for various sizes of CdTe single detectors were calculated for gamma rays using the Monte Carlo method. Also, escape and crosstalk ratios were simulated for the CdTe multi-channel detectors. The theoretical results were tested experimentally for 59.54-keV gamma rays from a 241 Am radioactive source. Results showed that escape ratios for single detectors were strongly dependent on element size and thickness. The escape and crosstalk ratios increased with closer channel pitch. The calculated results showed a good agreement with the experimental data. The calculations made it clear that K X-rays which escaped to neighboring channels induced crosstalk more frequently at smaller channel pitch in multichannel detectors. A radiation shielding grid which blocked incident photons between the boundary channels was also tested by experiment and by calculation. It was effective in reducing the probability of escape and crosstalk

  6. Multiplex multivariate recurrence network from multi-channel signals for revealing oil-water spatial flow behavior.

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Yang, Yu-Xuan; Cai, Qing

    2017-03-01

    The exploration of the spatial dynamical flow behaviors of oil-water flows has attracted increasing interests on account of its challenging complexity and great significance. We first technically design a double-layer distributed-sector conductance sensor and systematically carry out oil-water flow experiments to capture the spatial flow information. Based on the well-established recurrence network theory, we develop a novel multiplex multivariate recurrence network (MMRN) to fully and comprehensively fuse our double-layer multi-channel signals. Then we derive the projection networks from the inferred MMRNs and exploit the average clustering coefficient and the spectral radius to quantitatively characterize the nonlinear recurrent behaviors related to the distinct flow patterns. We find that these two network measures are very sensitive to the change of flow states and the distributions of network measures enable to uncover the spatial dynamical flow behaviors underlying different oil-water flow patterns. Our method paves the way for efficiently analyzing multi-channel signals from multi-layer sensor measurement system.

  7. Autonomous miniaturised device with USB interface for pulse height analysis and multi-channel scaling (TUKAN-8K-USB)

    International Nuclear Information System (INIS)

    Guzik, Z.; Borsuk, S.; Plominski, M.; Traczyk, K.

    2005-01-01

    We present autonomous a 8K-channel miniature device designed for spectroscopy or intensity vs. time measurements. The device (TUKAN-8K-USB) is based on the USB interface, and is contained in a screened separate box - it can be proved either directly from the USB port or from an external DC source (wall adapter of battery). The device may work in two independent operational modes: Multi-Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The crucial MCA component - Peak detect and Hold circuitry - is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with front edges down to 100 ns and has a differential linearity below 0.5% (full scale sliding scale averaging). Automatic stops on count in Region-Of-Interest (ROI) and on preset live or real time are implemented. The MCS works at medium speed counting rates (up to 8 MHz), with preset dwell time, number of channels and multi-sweep mode. Each these parameters can also be controlled externally. Digital interfacing is based on four used configurable logical I/O lines. A single CYCLONE EP1C3 Altera FPGA provides all control functions. The USB communication is based on FYDI FIFO controller. The analyzer is equipped with advanced, user-friendly software, which is subjected of another publication. )author)

  8. Harnessing mode-selective nonlinear optics for on-chip multi-channel all-optical signal processing

    Directory of Open Access Journals (Sweden)

    Ming Ma

    2016-11-01

    Full Text Available All-optical signal processing based on nonlinear optical effects allows for the realization of important functions in telecommunications including wavelength conversion, optical multiplexing/demultiplexing, Fourier transformation, and regeneration, amongst others, on ultrafast time scales to support high data rate transmission. In integrated photonic subsystems, the majority of all-optical signal processing systems demonstrated to date typically process only a single channel at a time or perform a single processing function, which imposes a serious limitation on the functionality of integrated solutions. Here, we demonstrate how nonlinear optical effects can be harnessed in a mode-selective manner to perform simultaneous multi-channel (two and multi-functional optical signal processing (i.e., regenerative wavelength conversion in an integrated silicon photonic device. This approach, which can be scaled to a higher number of channels, opens up a new degree of freedom for performing a broad range of multi-channel nonlinear optical signal processing functions using a single integrated photonic device.

  9. Body mass index and lung cancer risk in never smokers

    International Nuclear Information System (INIS)

    Kagohashi, K.; Satoh, H.; Kurishima, K.; Ishikawa, H.; Ohtsuka, M.

    2006-01-01

    Background. A relationship between body mass index (BMI) and lung cancer risk in never smokers has not been reported precisely. To evaluate the risk of lung cancer associated with BMI in never smokers, we conducted a case-control study. Methods. The relationship between BMI and the risk of lung cancer in never smokers was investigated in a study of 204 lung cancer cases and 398 controls admitted between 1987 and 2005. Controls were selected from hospitalized age-matched never-smoking patients with non-malignant respiratory disease. Results. When compared with BMI of the leanest group (BMI<20.8) in men, no inverse association between BMI and lung cancer was observed after the adjustment for age (the second BMI group: BMI≥ 20.8 to < 22.9; p=0.683, the third BMI group: BMI≥ 22.9 to < 24.9; p=0.745, and the highest BMI group: BMI≥ 25.0; p=0.327). Similarly, no association in women was found between BMI and lung cancer in these three BMI groups (the second group, p=0.639; the third group, p=0.667; the highest group, p=0.978) when compared with that of the leanest BMI group. Conclusions. Our present study indicated that the association between leanness and the risk of lung cancer might be influenced by other factors such as smoking. (author)

  10. Body mass index and risk of autoimmune diseases

    DEFF Research Database (Denmark)

    Harpsøe, Maria C; Basit, Saima; Andersson, Mikael

    2014-01-01

    .57) and type 1 diabetes mellitus (HR 2.67; 95% CI, 1.71 to 4.17). Risk of dermatitis herpetiformis increased by 14% (95% CI, 1% to 30%) per BMI unit. Conversely, risk of celiac disease and Raynaud's phenomenon decreased by 7% (95% CI, 1% to 13%) and 12% (95% CI, 4% to 19%) per BMI unit, respectively. Further......BACKGROUND: A possible aetiological link between obesity and certain autoimmune diseases (ADs) has been suggested. We investigated the associations between body mass index (BMI, kg/m2) and 43 ADs. METHODS: 75,008 women participating in the Danish National Birth Cohort were followed during a median......-up, 2430 women (3.2%) developed a total of 2607 new-onset ADs. Risk of any autoimmune disease was increased in obese women (HR, 1.27; 95% CI, 1.11 to 1.46) compared with normal weight women (18.5-≤25 kg/m2). Obese women (BMI≥30 kg/m2) were at increased risk of sarcoidosis (HR 3.59; 95% CI, 2.31 to 5...

  11. The Influence of Mass Media and Interpersonal Communication on Societal and Personal Risk Judgments.

    Science.gov (United States)

    Coleman, Cynthia-Lou.

    1993-01-01

    Examines the influence of mass media, interpersonal channels, and self-efficacy on risk judgment. Confirms that mass media channels influence social-level risk judgments. Finds that personal-level risk was influenced to some degree by mass media channels and that interpersonal channels and self-efficacy account for some variance on social-level…

  12. Evaluating the risk of osteoporosis through bone mass density

    International Nuclear Information System (INIS)

    Sayed, S.A.; Khaliq, A.

    2017-01-01

    Osteoporosis is a bone disorder, characterized by loss of bone mass density. Osteoporosis affects more than 30 percent of post-menopausal women. Osteoporosis is often associated with restricted body movement, pain and joint deformities. Early identification and early intervention can help in reducing these complications. The primary objective of this study was to estimate the burden of Osteoporosis in Urban setting of Sindh among women of different age groups and to access the effect of different protective measures that can reduce the risk of Osteoporosis. Method: In this study, 500 women's of 3 major cities of Sindh were approached by non-probability convenience sampling technique. Women bearing age 20 years or more were included. Women who fall under inclusion criteria were screened for BMD (Bone mineral density) test and were classified as Healthy, Osteopenic and Osteoporotic based on their T-score. The association of different protective measures and risk of osteoporosis was assessed by prevalence relative risk (PRR). Result: The result of this study indicate that the burden of Osteoporosis is very high among the women of Sindh, only 17.4 percent (84) women were found to have normal BMD score. The life style of majority of women was sedentary. The PRR calculated for Exposure to sunlight, regular exercise, and use of nutritional supplement was 12.5, 5.19 and 2.72 folds respectively. Conclusion: The results of study reveal that exposure to sunlight, regular physical exercise and use of nutritional supplements found to be effective in reducing the risk of osteoporosis among women of all age group. Health education and promotion toward osteoporosis prevention can significantly contribute in reducing the morbidity of osteoporosis. (author)

  13. Evaluating The Risk Of Osteoporosis Through Bone Mass Density.

    Science.gov (United States)

    Sayed, Sayeeda Amber; Khaliq, Asif; Mahmood, Ashar

    2016-01-01

    Osteoporosis is a bone disorder, characterized by loss of bone mass density. Osteoporosis affects more than 30% of post-menopausal women. Osteoporosis is often associated with restricted body movement, pain and joint deformities. Early identification and early intervention can help in reducing these complications. The primary objective of this study was to estimate the burden of Osteoporosis in Urban setting of Sindh among women of different age groups and to access the effect of different protective measures that can reduce the risk of Osteoporosis. In this study, 500 women's of 3 major cities of Sindh were approached by non-probability convenience sampling technique. Women bearing age 20 years or more were included. Women who fall under inclusion criteria were screened for BMD (Bone mineral density) test and were classified as Healthy, Osteopenic and Osteoporotic based on their T-score. The association of different protective measures and risk of osteoporosis was assessed by prevalence relative risk (PRR). The result of this study indicate that the burden of Osteoporosis is very high among the women of Sindh, only 17.4% (84) women were found to have normal BMD score. The life style of majority of women was sedentary. The PRR calculated for Exposure to sunlight, regular exercise, and use of nutritional supplement was 12.5, 5.19 and 2.72 folds respectively. The results of study reveal that exposure to sunlight, regular physical exercise and use of nutritional supplements found to be effective in reducing the risk of osteoporosis among women of all age group. Health education and promotion toward osteoporosis prevention can significantly contribute in reducing the morbidity of osteoporosis.

  14. Monitoring of active layer dynamics at a permafrost site on Svalbard using multi-channel ground-penetrating radar

    Directory of Open Access Journals (Sweden)

    S. Westermann

    2010-11-01

    Full Text Available Multi-channel ground-penetrating radar is used to investigate the late-summer evolution of the thaw depth and the average soil water content of the thawed active layer at a high-arctic continuous permafrost site on Svalbard, Norway. Between mid of August and mid of September 2008, five surveys have been conducted in gravelly soil over transect lengths of 130 and 175 m each. The maximum thaw depths range from 1.6 m to 2.0 m, so that they are among the deepest thaw depths recorded in sediments on Svalbard so far. The thaw depths increase by approximately 0.2 m between mid of August and beginning of September and subsequently remain constant until mid of September. The thaw rates are approximately constant over the entire length of the transects within the measurement accuracy of about 5 to 10 cm. The average volumetric soil water content of the thawed soil varies between 0.18 and 0.27 along the investigated transects. While the measurements do not show significant changes in soil water content over the first four weeks of the study, strong precipitation causes an increase in average soil water content of up to 0.04 during the last week. These values are in good agreement with evapotranspiration and precipitation rates measured in the vicinity of the the study site. While we cannot provide conclusive reasons for the detected spatial variability of the thaw depth at the study site, our measurements show that thaw depth and average soil water content are not directly correlated.

    The study demonstrates the potential of multi-channel ground-penetrating radar for mapping thaw depth in permafrost areas. The novel non-invasive technique is particularly useful when the thaw depth exceeds 1.5 m, so that it is hardly accessible by manual probing. In addition, multi-channel ground-penetrating radar holds potential for mapping the latent heat content of the active layer and for estimating weekly to monthly averages of the ground heat flux during the

  15. Body mass index and the risk of Parkinson disease.

    Science.gov (United States)

    Hu, G; Jousilahti, P; Nissinen, A; Antikainen, R; Kivipelto, M; Tuomilehto, J

    2006-12-12

    To examine the association between body mass index (BMI) and the risk of Parkinson disease (PD). Study cohorts included 22,367 Finnish men and 23,439 women 25 to 59 years of age without a history of PD at baseline. Hazards ratios (HRs) of incident PD were estimated for different levels of BMI. During a mean follow-up period of 18.8 years, 272 men and 254 women developed incident PD. After adjustment for confounding factors (age, study years, systolic blood pressure, total cholesterol, education, leisure-time physical activity, smoking, and alcohol, coffee, and tea consumption), the HRs of PD at different levels of BMI ( or =30 kg/m(2)) were 1.00, 1.97 (95% CI: 1.21 to 3.22), 1.83 (95% CI: 1.12 to 2.99), 2.34 (95% CI: 1.45 to 3.78), and 2.44 (95% CI: 1.44 to 4.15) in men, and 1.00, 1.50 (95% CI: 0.95 to 2.37), 1.65 (95% CI: 1.05 to 2.59), 1.79 (95% CI: 1.15 to 2.80), and 1.77 (95% CI: 1.12 to 2.78) in women, and 1.00, 1.70 (95% CI: 1.23 to 2.37), 1.70 (95% CI: 1.23 to 2.37), 2.02 (95% CI: 1.46 to 2.79), and 2.03 (95% CI: 1.44 to 2.85) in men and women combined (adjusted also for sex). In both sexes combined, the multivariate-adjusted direct association between BMI and the risk of PD was present both in subjects aged 25 to 49 years and 50 to 59 years, in never smokers and smokers and in participants diagnosed PD before and after 65 years of age. Body mass index is associated with a risk of Parkinson disease. The effect is graded and independent of other risk factors.

  16. [The perils of risk communication and the role of the mass media].

    Science.gov (United States)

    Rossmann, C; Brosius, H-B

    2013-01-01

    Based on theories and empirical results from communication science, the present paper provides an overview of the role of mass media in risk communication. It is guided by the following questions: How do risk issues find their way into the media and how does the media depict them? How do mass-mediated risk messages affect people's perception of risks, knowledge, attitudes, and behavior? What potential does the media have in disseminating health risk information in campaigns? Hence, the present paper aims to provide a basis for the appropriate use of mass media in health risk communication so as to make use of the potential of mass media without neglecting its limits.

  17. Highly Efficient Multi Channel Packet Forwarding with Round Robin Intermittent Periodic Transmit for Multihop Wireless Backhaul Networks

    Science.gov (United States)

    Furukawa, Hiroshi

    2017-01-01

    Round Robin based Intermittent Periodic Transmit (RR-IPT) has been proposed which achieves highly efficient multi-hop relays in multi-hop wireless backhaul networks (MWBN) where relay nodes are 2-dimensionally deployed. This paper newly investigates multi-channel packet scheduling and forwarding scheme for RR-IPT. Downlink traffic is forwarded by RR-IPT via one of the channels, while uplink traffic and part of downlink are accommodated in the other channel. By comparing IPT and carrier sense multiple access with collision avoidance (CSMA/CA) for uplink/downlink packet forwarding channel, IPT is more effective in reducing packet loss rate whereas CSMA/CA is better in terms of system throughput and packet delay improvement. PMID:29137164

  18. Multi Channels PWM Controller for Thermoelectric Cooler Using a Programmable Logic Device and Lab-Windows CVI

    Directory of Open Access Journals (Sweden)

    Eli FLAXER

    2008-09-01

    Full Text Available We present a complete design of a multi channels PID controller for Thermoelectric Cooler (TEC using a pulse width modulation (PWM technique implemented by a dedicated programmable logic device (PLD programmed by VHDL. The PID control loop is implemented by software written by National Instrument Lab-Windows CVI. Due to the fact that the implementation is by a VHDL and PLD the design is modular, as a result, the circuit is very compact in size and very low cost as compared to any commercial product. In addition, since the control loop is implemented by software running on a personal computer (PC using a C language, it is easy to adjust the controller to various environmental conditions and for a width range of sensors like: a thermo couple (TC, thermistor, resistance temperature detectors (RTD etc. We demonstrate the performance of this circuit as a controller for a small incubator using thermistor as the temperature sensor.

  19. Leveraging multi-channel x-ray detector technology to improve quality metrics for industrial and security applications

    Science.gov (United States)

    Jimenez, Edward S.; Thompson, Kyle R.; Stohn, Adriana; Goodner, Ryan N.

    2017-09-01

    Sandia National Laboratories has recently developed the capability to acquire multi-channel radio- graphs for multiple research and development applications in industry and security. This capability allows for the acquisition of x-ray radiographs or sinogram data to be acquired at up to 300 keV with up to 128 channels per pixel. This work will investigate whether multiple quality metrics for computed tomography can actually benefit from binned projection data compared to traditionally acquired grayscale sinogram data. Features and metrics to be evaluated include the ability to dis- tinguish between two different materials with similar absorption properties, artifact reduction, and signal-to-noise for both raw data and reconstructed volumetric data. The impact of this technology to non-destructive evaluation, national security, and industry is wide-ranging and has to potential to improve upon many inspection methods such as dual-energy methods, material identification, object segmentation, and computer vision on radiographs.

  20. New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, Andrey V.; Egorov, Dmitry V. [LPP “EqualiZoom”, Astana, 010000 (Kazakhstan)

    2016-06-08

    This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

  1. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    International Nuclear Information System (INIS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Bosse, Harald; Tan, Jiubin

    2015-01-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications. (paper)

  2. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    Science.gov (United States)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  3. A Read-out and Data Acquisition System for the Outputs of Multi-channel Spectroscopy Amplifiers

    International Nuclear Information System (INIS)

    Kong Jie; Qian Yi; Su Hong; Dong Chengfu

    2009-01-01

    A read-out and data acquisition system for the outputs of multi-channel spectroscopy amplifiers is introduced briefly in this paper. The 16-channel gating integrator/multiplexer developed by us and PXI-DAQ card are used to construct this system. A virtual instrument system for displaying, indicating,measuring and recording of output waveform is accomplished by integrating the PC, hardware, software together flexibly based on the Lab Windows/CVI platform in our read-out and data acquisition system. In this system, an ADC can face the 16 outputs of 16-channel spectroscopy amplifiers, which can improve the system integration and reduce the cost of data acquisition system. The design provided a new way for building the read-out and data acquisition system using the normal modules and spectroscopy amplifiers. This system has been tested and demonstrated that it is intelligent, reliable, real-time and low cost. (authors)

  4. Development of hybrid micro circuit based multi-channel programmable HV supply for BARC-pelletron experimental facility

    International Nuclear Information System (INIS)

    Manna, A.; Thombare, S.; Moitra, S.; Kuswarkar, M.; Punna, M.; Nair, P.M.; Diwakar, M.P.; Pithawa, C.K.

    2013-01-01

    Electronics Division, BARC has developed a Multi channel programmable HV bias supply system for charge particle detector array for use in BARC-TIFR Pelletron-LINAC facility. The HV supplies are compact in size due to use of hybrid micro-circuits developed indigenously and are modular in construction to achieve versatility, scalability and serviceability. All programming operations and monitoring are performed remotely through PC over Ethernet. Each supply has a built-in over voltage, over current and thermal overload protections for safe operation and employs a Zero Voltage Switching (ZVS) technique to reduce thermal stress on the inverter switches. This article describes salient design aspects and performance of the HV supply system. (author)

  5. Benchmarking and qualification of the nufreq-npw code for best estimate prediction of multi-channel core stability margins

    International Nuclear Information System (INIS)

    Taleyarkhan, R.; McFarlane, A.F.; Lahey, R.T. Jr.; Podowski, M.Z.

    1988-01-01

    The work described in this paper is focused on the development, verification and benchmarking of the NUFREQ-NPW code at Westinghouse, USA for best estimate prediction of multi-channel core stability margins in US BWRs. Various models incorporated into NUFREQ-NPW are systematically compared against the Westinghouse channel stability analysis code MAZDA, which the Mathematical Model was developed in an entirely different manner. The NUFREQ-NPW code is extensively benchmarked against experimental stability data with and without nuclear reactivity feedback. Detailed comparisons are next performed against nuclear-coupled core stability data. A physically based algorithm is developed to correct for the effect of flow development on subcooled boiling. Use of this algorithm (to be described in the full paper) captures the peak magnitude as well as the resonance frequency with good accuracy

  6. Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Cho, Chan Hee; Cho, Hyun Joon

    2009-01-01

    Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needs for development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

  7. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  8. The dynamic time-over-threshold method for multi-channel APD based gamma-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Orita, T., E-mail: orita.tadashi@jaea.go.jp [Japan Atomic Energy Agency, Fukushima (Japan); Shimazoe, K.; Takahashi, H. [Department of Nuclear Management and Engineering, The University of Tokyo, Bunkyō (Japan)

    2015-03-01

    t– Recent advances in manufacturing technology have enabled the use of multi-channel pixelated detectors in gamma-ray imaging applications. When obtaining gamma-ray measurements, it is important to obtain pulse height information in order to avoid unnecessary events such as scattering. However, as the number of channels increases, more electronics are needed to process each channel's signal, and the corresponding increases in circuit size and power consumption can result in practical problems. The time-over-threshold (ToT) method, which has recently become popular in the medical field, is a signal processing technique that can effectively avoid such problems. However, ToT suffers from poor linearity and its dynamic range is limited. We therefore propose a new ToT technique called the dynamic time-over-threshold (dToT) method [4]. A new signal processing system using dToT and CR-RC shaping demonstrated much better linearity than that of a conventional ToT. Using a test circuit with a new Gd{sub 3}Al{sub 2}Ga{sub 3}O{sub 12} (GAGG) scintillator and an avalanche photodiode, the pulse height spectra of {sup 137}Cs and {sup 22}Na sources were measured with high linearity. Based on these results, we designed a new application-specific integrated circuit (ASIC) for this multi-channel dToT system, measured the spectra of a {sup 22}Na source, and investigated the linearity of the system.

  9. TUKAN—An 8K Pulse Height Analyzer and Multi-Channel Scaler With a PCI or a USB Interface

    Science.gov (United States)

    Guzik, Z.; Borsuk, S.; Traczyk, K.; Plominski, M.

    2006-02-01

    In this paper we present two types of 8K-channel analyzers designed for spectroscopy and intensity versus time measurements. The first type (Tukan-8K-PCI) incorporates a PCI interface and is designed to be plugged into a PCI slot of a normal PC. The second type (Tukan-8K-USB) incorporates a USB interface. It is mounted in a separate screened box and can be powered either directly from the USB port or from an external dc source (wall adapter or battery). Each type of device may operate in either of two independent operational modes: Multi Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The most crucial component for the MCA mode-the Peak Detect and Hold circuit-is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with rise times as short as 100 ns and has a differential linearity below 1% with sliding scale averaging over the full scale. The functionality includes automatic stop on a programmable count in the Region-Of-Interest (ROI) and on preset live- or real time. The MCS mode works at medium counting rates of up to 8 MHz. The dwell time, the number of channels and single or multi-sweep mode may be preset. Each of these parameters can also be controlled externally via four user configurable logical I/O lines. A single Altera FLEX 10KE30 FPGA provides all control functions and incorporates PCI interface. The USB interface is based on FTDI FIFO controller. Advanced and user-friendly software has been developed for the analyzer

  10. A Radiation Hard Multi-Channel Digitizer ASIC for Operation in the Harsh Jovian Environment

    Science.gov (United States)

    Aslam, Shahid; Aslam, S.; Akturk, A.; Quilligan, G.

    2011-01-01

    ultimately impact the surface of Europa after the mission is completed. The current JEO mission concept includes a range of instruments on the payload, to monitor dynamic phenomena (such as Io's volcanoes and Jupiters atmosphere), map the Jovian magnetosphere and its interactions with the Galilean satellites, and characterize water oceans beneath the ice shells of Europa and Ganymede. The payload includes a low mass (3.7 Kg) and low power (ASIC that resides very close to the thermopile linear array outputs. Both the thermopile array and the MCD ASIC will need to show full functionality within the harsh Jovian radiation environment, operating at cryogenic temperatures, typically 150 K to 170 K. In the following, a radiation mitigation strategy together with a low risk Radiation-Hardened-By-Design (RHBD) methodology using commercial foundry processes is given for the design and manufacture of a MCD ASIC that will meet this challenge.

  11. Adaptive multi-channel downlink assignment for overloaded spectrum-shared multi-antenna overlaid cellular networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2012-10-19

    Overlaid cellular technology has been considered as a promising candidate to enhance the capacity and extend the coverage of cellular networks, particularly indoors. The deployment of small cells (e.g. femtocells and/or picocells) in an overlaid setup is expected to reduce the operational power and to function satisfactorily with the existing cellular architecture. Among the possible deployments of small-cell access points is to manage many of them to serve specific spatial locations, while reusing the available spectrum universally. This contribution considers the aforementioned scenario with the objective to serve as many active users as possible when the available downlink spectrum is overloaded. The case study is motivated by the importance of realizing universal resource sharing in overlaid networks, while reducing the load of distributing available resources, satisfying downlink multi-channel assignment, controlling the aggregate level of interference, and maintaining desired design/operation requirements. These objectives need to be achieved in distributed manner in each spatial space with as low processing load as possible when the feedback links are capacity-limited, multiple small-cell access points can be shared, and data exchange between access points can not be coordinated. This contribution is summarized as follows. An adaptive downlink multi-channel assignment scheme when multiple co-channel and shared small-cell access points are allocated to serve active users is proposed. It is assumed that the deployed access points employ isotropic antenna arrays of arbitrary sizes, operate using the open-access strategy, and transmit on shared physical channels simultaneously. Moreover, each active user can be served by a single transmit channel per each access point at a time, and can sense the concurrent interference level associated with each transmit antenna channel non-coherently. The proposed scheme aims to identify a suitable subset of transmit channels

  12. Development and field example of multi channel surface wave data acquisition and processing system (SWS-1); Multi channel hyomenha data shutoku shori system (SWS-1) no kaihatsu to jikkenrei

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Huashui Institute of Geophysical Exploration, (China); Wang, Z [Bureauof Engineering MGMR, (China); Zhang, Z [STG Corp., (China); Tanaka, Y

    1996-05-01

    A report is given here about the use of a newly-developed multi-channel surface wave data acquisition and processing system different from the conventional surface wave exploration device. This system enables the on-site pickup of a dispersion curve out of the multi-component surface wave data and, in the analysis of underground structure, performs the forward modeling and inversion. The system, furthermore, acquires and analyzes the data obtained from reflection earthquake exploration and constant microtremor observation. During a survey conducted along the highway from Port Ren-un to Xuzhou, China, estimation of the basement boundary was made by use of dynamite, and what was obtained agreed with the result of boring though with an error of 3m. In addition, this system could probe levels deeper than 100m using the instantaneous Rayleigh wave exploration method. This system and the conventional surface exploration device were compared in a soft ground in Fukui Prefecture, the former using a 10kg hammer and the latter using a 350kg exciter, when it was verified that the results produced by both techniques excellently agree with the geologic columnar section and changes in the N-value. 4 refs., 4 figs.

  13. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2013-06-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  14. Joint image reconstruction method with correlative multi-channel prior for x-ray spectral computed tomography

    Science.gov (United States)

    Kazantsev, Daniil; Jørgensen, Jakob S.; Andersen, Martin S.; Lionheart, William R. B.; Lee, Peter D.; Withers, Philip J.

    2018-06-01

    Rapid developments in photon-counting and energy-discriminating detectors have the potential to provide an additional spectral dimension to conventional x-ray grayscale imaging. Reconstructed spectroscopic tomographic data can be used to distinguish individual materials by characteristic absorption peaks. The acquired energy-binned data, however, suffer from low signal-to-noise ratio, acquisition artifacts, and frequently angular undersampled conditions. New regularized iterative reconstruction methods have the potential to produce higher quality images and since energy channels are mutually correlated it can be advantageous to exploit this additional knowledge. In this paper, we propose a novel method which jointly reconstructs all energy channels while imposing a strong structural correlation. The core of the proposed algorithm is to employ a variational framework of parallel level sets to encourage joint smoothing directions. In particular, the method selects reference channels from which to propagate structure in an adaptive and stochastic way while preferring channels with a high data signal-to-noise ratio. The method is compared with current state-of-the-art multi-channel reconstruction techniques including channel-wise total variation and correlative total nuclear variation regularization. Realistic simulation experiments demonstrate the performance improvements achievable by using correlative regularization methods.

  15. Vehicular Networking Enhancement And Multi-Channel Routing Optimization, Based on Multi-Objective Metric and Minimum Spanning Tree

    Directory of Open Access Journals (Sweden)

    Peppino Fazio

    2013-01-01

    Full Text Available Vehicular Ad hoc NETworks (VANETs represent a particular mobile technology that permits the communication among vehicles, offering security and comfort. Nowadays, distributed mobile wireless computing is becoming a very important communications paradigm, due to its flexibility to adapt to different mobile applications. VANETs are a practical example of data exchanging among real mobile nodes. To enable communications within an ad-hoc network, characterized by continuous node movements, routing protocols are needed to react to frequent changes in network topology. In this paper, the attention is focused mainly on the network layer of VANETs, proposing a novel approach to reduce the interference level during mobile transmission, based on the multi-channel nature of IEEE 802.11p (1609.4 standard. In this work a new routing protocol based on Distance Vector algorithm is presented to reduce the delay end to end and to increase packet delivery ratio (PDR and throughput in VANETs. A new metric is also proposed, based on the maximization of the average Signal-to-Interference Ratio (SIR level and the link duration probability between two VANET nodes. In order to relieve the effects of the co-channel interference perceived by mobile nodes, transmission channels are switched on a basis of a periodical SIR evaluation. A Network Simulator has been used for implementing and testing the proposed idea.

  16. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud; Qaraqe, Khalid A.; Alouini, Mohamed-Slim

    2013-01-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  17. New geological interpretation of multi-channel seismic profiles from the Pacific Margin of the Antarctic Peninsula

    Directory of Open Access Journals (Sweden)

    Okoń Jan

    2016-06-01

    Full Text Available The Polish Geophysical Expedition to West Antarctica in 1979–1980 was carried out by the Institute of Geophysics, Polish Academy of Sciences. Beside deep seismic soundings, 12 multi-channel seismic profiles, with a total length of ca 1000 km have been recorded north and east of the South Shetland Islands and in the Bransfield Strait, but they have never before been completely interpreted and published. All profiles have been processed with modern processing flow including time migration. Profiles crossing the South Shetland Trench revealed distinct reflector inside continental slope, which has been interpreted as border between buried accretionary prism and overlying slope sediments of glacial-marine origin. Profiles in the Bransfield Strait show traces of the Last Glacial Maximum (LGM in the form of glacial foreground valleys, with some of them used as weak spots for young age volcanic intrusions. This paper is the first comprehensive geological interpretation of collected dataset and differences between results from other expeditions are discussed.

  18. BDNF gene delivery within and beyond templated agarose multi-channel guidance scaffolds enhances peripheral nerve regeneration

    Science.gov (United States)

    Gao, Mingyong; Lu, Paul; Lynam, Dan; Bednark, Bridget; Campana, W. Marie; Sakamoto, Jeff; Tuszynski, Mark

    2016-12-01

    Objective. We combined implantation of multi-channel templated agarose scaffolds with growth factor gene delivery to examine whether this combinatorial treatment can enhance peripheral axonal regeneration through long sciatic nerve gaps. Approach. 15 mm long scaffolds were templated into highly organized, strictly linear channels, mimicking the linear organization of natural nerves into fascicles of related function. Scaffolds were filled with syngeneic bone marrow stromal cells (MSCs) secreting the growth factor brain derived neurotrophic factor (BDNF), and lentiviral vectors expressing BDNF were injected into the sciatic nerve segment distal to the scaffold implantation site. Main results. Twelve weeks after injury, scaffolds supported highly linear regeneration of host axons across the 15 mm lesion gap. The incorporation of BDNF-secreting cells into scaffolds significantly increased axonal regeneration, and additional injection of viral vectors expressing BDNF into the distal segment of the transected nerve significantly enhanced axonal regeneration beyond the lesion. Significance. Combinatorial treatment with multichannel bioengineered scaffolds and distal growth factor delivery significantly improves peripheral nerve repair, rivaling the gold standard of autografts.

  19. Spectrum-efficient multi-channel design for coexisting IEEE 802.15.4 networks: A stochastic geometry approach

    KAUST Repository

    Elsawy, Hesham

    2014-07-01

    For networks with random topologies (e.g., wireless ad-hoc and sensor networks) and dynamically varying channel gains, choosing the long term operating parameters that optimize the network performance metrics is very challenging. In this paper, we use stochastic geometry analysis to develop a novel framework to design spectrum-efficient multi-channel random wireless networks based on the IEEE 802.15.4 standard. The proposed framework maximizes both spatial and time domain frequency utilization under channel gain uncertainties to minimize the number of frequency channels required to accommodate a certain population of coexisting IEEE 802.15.4 networks. The performance metrics are the outage probability and the self admission failure probability. We relax the single channel assumption that has been used traditionally in the stochastic geometry analysis. We show that the intensity of the admitted networks does not increase linearly with the number of channels and the rate of increase of the intensity of the admitted networks decreases with the number of channels. By using graph theory, we obtain the minimum required number of channels to accommodate a certain intensity of coexisting networks under a self admission failure probability constraint. To this end, we design a superframe structure for the coexisting IEEE 802.15.4 networks and a method for time-domain interference alignment. © 2002-2012 IEEE.

  20. Ab initio R-matrix/Multi-channel Quantum Defect Theory applied to Molecular Core Excitation and Ionization

    International Nuclear Information System (INIS)

    Hiyama, M.; Kosugi, N.

    2004-01-01

    Full text: Ab initio R-matrix/MQDT approach, which is a combination of ab initio R-matrix techniques and the multi channel quantum defect theory (MQDT), has recently been developed by one of the present authors (MH) and Child, to successfully obtain the potential energy curves of Rydberg states converging to not only the lowest but also the higher ionized states. This approach is also applied to estimate the valence state interaction with Rydberg and continuum (ionization) channels. Very recently we have made an original ab initio polyatomic R-matrix/MQDT program package, GSCF4R based on Gaussian type basis functions for the bound and continuum states, to extensively study molecular excitation and ionization in the X-ray region as well as in the VUV region. We are going to report the results for core excitation and ionization of diatomic molecules such as NO and O 2 to show that the R-matrix/MQDT method is indispensable to describe the core-to-Rydberg states with the higher quantum number and the continuum states. These results lead us to the conclusion that the close-coupling approximation augmented with the correlation term within the R-matrix/MQDT formalism is powerful to calculate the Rydberg-valence mixing and the interchannel coupling between several core-ionized states

  1. 'Too much, too late': mixed methods multi-channel video recording study of computerized decision support systems and GP prescribing.

    Science.gov (United States)

    Hayward, James; Thomson, Fionagh; Milne, Heather; Buckingham, Susan; Sheikh, Aziz; Fernando, Bernard; Cresswell, Kathrin; Williams, Robin; Pinnock, Hilary

    2013-06-01

    Computerized decision support systems (CDSS) are commonly deployed to support prescribing, although over-riding of alerts by prescribers remains a concern. We aimed to understand how general practitioners (GPs) interact with prescribing CDSS in order to inform deliberation on how better to support prescribing decisions in primary care. Quantitative and qualitative analysis of interactions between GPs, patients, and computer systems using multi-channel video recordings of 112 primary care consultations with eight GPs in three UK practices. 132 prescriptions were issued in the course of 73 of the consultations, of which 81 (61%) attracted at least one alert. Of the total of 117 alerts, only three resulted in the GP checking, but not altering, the prescription. CDSS provided information and safety alerts at the point of generating a prescription. This was 'too much, too late' as the majority of the 'work' of prescribing occurred prior to using the computer. By the time an alert appeared, the GP had formulated the problem(s), potentially spent several minutes considering, explaining, negotiating, and reaching agreement with the patient about the proposed treatment, and had possibly given instructions and printed an information leaflet. CDSS alerts do not coincide with the prescribing workflow throughout the whole GP consultation. Current systems interrupt to correct decisions that have already been taken, rather than assisting formulation of the management plan. CDSS are likely to be more acceptable and effective if the prescribing support is provided much earlier in the process of generating a prescription.

  2. Research on multi - channel interactive virtual assembly system for power equipment under the “VR+” era

    Science.gov (United States)

    Ren, Yilong; Duan, Xitong; Wu, Lei; He, Jin; Xu, Wu

    2017-06-01

    With the development of the “VR+” era, the traditional virtual assembly system of power equipment has been unable to satisfy our growing needs. In this paper, based on the analysis of the traditional virtual assembly system of electric power equipment and the application of VR technology in the virtual assembly system of electric power equipment in our country, this paper puts forward the scheme of establishing the virtual assembly system of power equipment: At first, we should obtain the information of power equipment, then we should using OpenGL and multi texture technology to build 3D solid graphics library. After the completion of three-dimensional modeling, we can use the dynamic link library DLL package three-dimensional solid graphics generation program to realize the modularization of power equipment model library and power equipment model library generated hidden algorithm. After the establishment of 3D power equipment model database, we set up the virtual assembly system of 3D power equipment to separate the assembly operation of the power equipment from the space. At the same time, aiming at the deficiency of the traditional gesture recognition algorithm, we propose a gesture recognition algorithm based on improved PSO algorithm for BP neural network data glove. Finally, the virtual assembly system of power equipment can really achieve multi-channel interaction function.

  3. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-10-01

    Full Text Available This study presents the use of a multi-channel opto-electronic sensor (OEPS to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA, and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05; a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001; the bias of BAA 0.85 bpm, the standard deviation (SD 9.20 bpm, and the limits of agreement (LOA from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001; the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  4. Sum Utilization of Spectrum with Spectrum Handoff and Imperfect Sensing in Interweave Multi-Channel Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Waqas Khalid

    2018-05-01

    Full Text Available Fifth-generation (5G heterogeneous network deployment poses new challenges for 5G-based cognitive radio networks (5G-CRNs as the primary user (PU is required to be more active because of the small cells, random user arrival, and spectrum handoff. Interweave CRNs (I-CRNs improve spectrum utilization by allowing opportunistic spectrum access (OSA for secondary users (SUs. The sum utilization of spectrum, i.e., joint utilization of spectrum by the SU and PU, depends on the spatial and temporal variations of PU activities, sensing outcomes, transmitting conditions, and spectrum handoff. In this study, we formulate and analyze the sum utilization of spectrum with different sets of channels under different PU and SU co-existing network topologies. We consider realistic multi-channel scenarios for the SU, with each channel licensed to a PU. The SU, aided by spectrum handoff, is authorized to utilize the channels on the basis of sensing outcomes and PU interruptions. The numerical evaluation of the proposed work is presented under different network and sensing parameters. Moreover, the sum utilization gain is investigated to analyze the sensitivities of different sensing parameters. It is demonstrated that different sets of channels, PU activities, and sensing outcomes have a significant impact on the sum utilization of spectrum associated with a specific network topology.

  5. Evaluation of the potential of soil remediation by direct multi-channel pulsed corona discharge in soil.

    Science.gov (United States)

    Wang, Tie Cheng; Qu, Guangzhou; Li, Jie; Liang, Dongli

    2014-01-15

    A novel approach, named multi-channel pulsed corona discharge in soil, was developed for remediating organic pollutants contaminated soil, with p-nitrophenol (PNP) as the model pollutant. The feasibility of PNP degradation in soil was explored by evaluating effects of pulse discharge voltage, air flow rate and soil moisture on PNP degradation. Based on roles of chemically active species and evolution of degradation intermediates, PNP degradation processes were discussed. Experimental results showed that about 89.4% of PNP was smoothly degraded within 60min of discharge treatment at pulse discharge voltage 27kV, soil moisture 5% and air flow rate 0.8Lmin(-1), and the degradation process fitted the first-order kinetic model. Increasing pulse discharge voltage was found to be favorable for PNP degradation, but not for energy yield. There existed appropriate air flow rate and soil moisture for obtaining gratifying PNP degradation efficacy. Roles of radical scavenger and measurement of active species suggested that ozone, H2O2, and OH radicals played very important roles in PNP degradation. CN bond in PNP molecule was cleaved, and the main intermediate products such as hydroquinone, benzoquinone, catechol, phenol, acetic acid, formic acid, oxalic acid, NO2(-) and NO3(-) were identified. Possible pathway of PNP degradation in soil in such a system was proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Benchmarking and qualification of the NUFREQ-NPW code for best estimate prediction of multi-channel core stability margins

    International Nuclear Information System (INIS)

    Taleyarkhan, R.; Lahey, R.T. Jr.; McFarlane, A.F.; Podowski, M.Z.

    1988-01-01

    The NUFREQ-NPW code was modified and set up at Westinghouse, USA for mixed fuel type multi-channel core-wide stability analysis. The resulting code, NUFREQ-NPW, allows for variable axial power profiles between channel groups and can handle mixed fuel types. Various models incorporated into NUFREQ-NPW were systematically compared against the Westinghouse channel stability analysis code MAZDA-NF, for which the mathematical model was developed, in an entirely different manner. Excellent agreement was obtained which verified the thermal-hydraulic modeling and coding aspects. Detailed comparisons were also performed against nuclear-coupled reactor core stability data. All thirteen Peach Bottom-2 EOC-2/3 low flow stability tests were simulated. A key aspect for code qualification involved the development of a physically based empirical algorithm to correct for the effect of core inlet flow development on subcooled boiling. Various other modeling assumptions were tested and sensitivity studies performed. Good agreement was obtained between NUFREQ-NPW predictions and data. Moreover, predictions were generally on the conservative side. The results of detailed direct comparisons with experimental data using the NUFREQ-NPW code; have demonstrated that BWR core stability margins are conservatively predicted, and all data trends are captured with good accuracy. The methodology is thus suitable for BWR design and licensing purposes. 11 refs., 12 figs., 2 tabs

  7. Leveraging accelerated testing of LED drivers to model the reliability of two-stage and multi-channel drivers

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Perkins, Curtis; Smith, Aaron; Clark, Terry; Mills, Karmann

    2017-05-30

    The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level of control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.

  8. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  9. Multi-Channel Electroencephalogram (EEG) Signal Acquisition and its Effective Channel selection with De-noising Using AWICA for Biometric System

    OpenAIRE

    B.Sabarigiri; D.Suganyadevi

    2014-01-01

    the embedding of low cost electroencephalogram (EEG) sensors in wireless headsets gives improved authentication based on their brain wave signals has become a practical opportunity. In this paper signal acquisition along with effective multi-channel selection from a specific area of the brain and denoising using AWICA methods are proposed for EEG based personal identification. At this point, to develop identification system the steps are as follows. (i) the high-quality device with the least ...

  10. Multi-channel and porous SiO@N-doped C rods as anodes for high-performance lithium-ion batteries

    Science.gov (United States)

    Huang, Xiao; Li, Mingqi

    2018-05-01

    To improve the cycling stability and rate capability of SiO electrodes, multi-channel and porous SiO@N-doped C (mp-SiO@N-doped C) rods are fabricated by the combination of electrospinning and heat treatment with the assistance of poly(methyl methacrylate) (PMMA). During annealing, in-situ PMMA degradation and gasification lead to the formation of multi-channel structure and more pores. As anodes for lithium ion batteries, the mp-SiO@N-doped C rods exhibit excellent cycling stability. At a current density of 400 mA g-1, a discharge capacity of 806 mAh g-1 can be kept after 250 cycles, the retention of which is over than 100% versus the initial reversible capacity. Compared with the SiO@N-doped C rods synthesized without the help of PMMA, the mp-SiO@N-doped C rods exhibit more excellent rate capability. The excellent electrochemical performance is attributed to the special structure of the mp-SiO@N-doped C rods. In addition to the conductivity improved by carbon fibers, the multi-channel and porous structures not only make ions/electrons transfer and electrolyte diffusion easier, but also contribute to the structural stability of the electrodes.

  11. Exploring the complementarity of THz pulse imaging and DCE-MRIs: Toward a unified multi-channel classification and a deep learning framework.

    Science.gov (United States)

    Yin, X-X; Zhang, Y; Cao, J; Wu, J-L; Hadjiloucas, S

    2016-12-01

    We provide a comprehensive account of recent advances in biomedical image analysis and classification from two complementary imaging modalities: terahertz (THz) pulse imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The work aims to highlight underlining commonalities in both data structures so that a common multi-channel data fusion framework can be developed. Signal pre-processing in both datasets is discussed briefly taking into consideration advances in multi-resolution analysis and model based fractional order calculus system identification. Developments in statistical signal processing using principal component and independent component analysis are also considered. These algorithms have been developed independently by the THz-pulse imaging and DCE-MRI communities, and there is scope to place them in a common multi-channel framework to provide better software standardization at the pre-processing de-noising stage. A comprehensive discussion of feature selection strategies is also provided and the importance of preserving textural information is highlighted. Feature extraction and classification methods taking into consideration recent advances in support vector machine (SVM) and extreme learning machine (ELM) classifiers and their complex extensions are presented. An outlook on Clifford algebra classifiers and deep learning techniques suitable to both types of datasets is also provided. The work points toward the direction of developing a new unified multi-channel signal processing framework for biomedical image analysis that will explore synergies from both sensing modalities for inferring disease proliferation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. [Multi-channel in vivo recording techniques: analysis of phase coupling between spikes and rhythmic oscillations of local field potentials].

    Science.gov (United States)

    Wang, Ce-Qun; Chen, Qiang; Zhang, Lu; Xu, Jia-Min; Lin, Long-Nian

    2014-12-25

    The purpose of this article is to introduce the measurements of phase coupling between spikes and rhythmic oscillations of local field potentials (LFPs). Multi-channel in vivo recording techniques allow us to record ensemble neuronal activity and LFPs simultaneously from the same sites in the brain. Neuronal activity is generally characterized by temporal spike sequences, while LFPs contain oscillatory rhythms in different frequency ranges. Phase coupling analysis can reveal the temporal relationships between neuronal firing and LFP rhythms. As the first step, the instantaneous phase of LFP rhythms can be calculated using Hilbert transform, and then for each time-stamped spike occurred during an oscillatory epoch, we marked instantaneous phase of the LFP at that time stamp. Finally, the phase relationships between the neuronal firing and LFP rhythms were determined by examining the distribution of the firing phase. Phase-locked spikes are revealed by the non-random distribution of spike phase. Theta phase precession is a unique phase relationship between neuronal firing and LFPs, which is one of the basic features of hippocampal place cells. Place cells show rhythmic burst firing following theta oscillation within a place field. And phase precession refers to that rhythmic burst firing shifted in a systematic way during traversal of the field, moving progressively forward on each theta cycle. This relation between phase and position can be described by a linear model, and phase precession is commonly quantified with a circular-linear coefficient. Phase coupling analysis helps us to better understand the temporal information coding between neuronal firing and LFPs.

  13. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    Science.gov (United States)

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.

  14. Automatic extraction and processing of small RNAs on a multi-well/multi-channel (M&M) chip.

    Science.gov (United States)

    Zhong, Runtao; Flack, Kenneth; Zhong, Wenwan

    2012-12-07

    The study of the regulatory roles in small RNAs can be accelerated by techniques that permit simple, low-cost, and rapid extraction of small RNAs from a small number of cells. In order to ensure highly specific and sensitive detection, the extracted RNAs should be free of the background nucleic acids and present stably in a small volume. To meet these criteria, we designed a multi-well/multi-channel (M&M) chip to carry out automatic and selective isolation of small RNAs via solid-phase extraction (SPE), followed by reverse-transcription (RT) to convert them to the more stable cDNAs in a final volume of 2 μL. Droplets containing buffers for RNA binding, washing, and elution were trapped in microwells, which were connected by one channel, and suspended in mineral oil. The silica magnetic particles (SMPs) for SPE were moved along the channel from well to well, i.e. in between droplets, by a fixed magnet and a translation stage, allowing the nucleic acid fragments to bind to the SMPs, be washed, and then be eluted for RT reaction within 15 minutes. RNAs shorter than 63 nt were selectively enriched from cell lysates, with recovery comparable to that of a commercial kit. Physical separation of the droplets on our M&M chip allowed the usage of multiple channels for parallel processing of multiple samples. It also permitted smooth integration with on-chip RT-PCR, which simultaneously detected the target microRNA, mir-191, expressed in fewer than 10 cancer cells. Our results have demonstrated that the M&M chip device is a valuable and cost-saving platform for studying small RNA expression patterns in a limited number of cells with reasonable sample throughput.

  15. Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI

    Science.gov (United States)

    Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A.

    2018-01-01

    Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10–30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected. PMID:29410611

  16. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    Science.gov (United States)

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  17. An Improved Cloud Classification Algorithm for China's FY-2C Multi-Channel Images Using Artificial Neural Network.

    Science.gov (United States)

    Liu, Yu; Xia, Jun; Shi, Chun-Xiang; Hong, Yang

    2009-01-01

    The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China's first operational geostationary meteorological satellite FengYun-2C (FY-2C) data. First, the capabilities of six widely-used Artificial Neural Network (ANN) methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA) and a Support Vector Machine (SVM), using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm) imagery. The result shows that: (1) ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2) among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM) and Probabilistic Neural Network (PNN). Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  18. An Improved Cloud Classification Algorithm for China’s FY-2C Multi-Channel Images Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Chun-Xiang Shi

    2009-07-01

    Full Text Available The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China’s first operational geostationary meteorological satellite FengYun-2C (FY-2C data. First, the capabilities of six widely-used Artificial Neural Network (ANN methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA and a Support Vector Machine (SVM, using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm imagery. The result shows that: (1 ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2 among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM and Probabilistic Neural Network (PNN. Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  19. Investigation of verbal and visual working memory by multi-channel time-resolved functional near-infrared spectroscopy

    Science.gov (United States)

    Contini, D.; Caffini, M.; Re, R.; Zucchelli, L.; Spinelli, L.; Basso Moro, S.; Bisconti, S.; Ferrari, M.; Quaresima, V.; Cutini, S.; Torricelli, A.

    2013-03-01

    Working memory (WM) is fundamental for a number of cognitive processes, such as comprehension, reasoning and learning. WM allows the short-term maintenance and manipulation of the information selected by attentional processes. The goal of this study was to examine by time-resolved fNIRS neural correlates of the verbal and visual WM during forward and backward digit span (DF and DB, respectively) tasks, and symbol span (SS) task. A neural dissociation was hypothesised between the maintenance and manipulation processes. In particular, a dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) recruitment was expected during the DB task, whilst a lateralised involvement of Brodmann Area (BA) 10 was expected during the execution of the DF task. Thirteen subjects were monitored by a multi-channel, dual-wavelength (690 and 829 nm) time-resolved fNIRS system during 3 minutes long DF and DB tasks and 4 minutes long SS task. The participants' mean memory span was calculated for each task: DF: 6.46+/-1.05 digits; DB: 5.62+/-1.26 digits; SS: 4.69+/-1.32 symbols. No correlation was found between the span level and the heart rate data (measured by pulse oximeter). As expected, DB elicited a broad activated area, in the bilateral VLPFC and the right DLPFC, whereas a more localised activation was observed over the right hemisphere during either DF (BA 10) or SS (BA 10 and 44). The robust involvement of the DLPFC during DB, compared to DF, is compatible with previous findings and with the key role of the central executive subserving in manipulating processes.

  20. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    Directory of Open Access Journals (Sweden)

    Samuel M Shin

    2015-09-01

    Full Text Available Introduction: Evaluate use of novel multi-channel applicator (MC CapriTM to improve vaginal disease coverage achievable by single-channel applicator (SC and comparable to Syed plan simulation. Material and Methods: 28 plans were evaluated from 4 patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by 3 weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth to 1500 cGy/3 fractions with a simultaneous integrated boost totaling 2100 cGy/3 fractions to tumor. Modeling of SC and Syed plans was performed using MC scans for each patient. Dosimetry for MC and SC plans was evaluated for PTV700 cGy coverage, maximum dose to 2cm3 to bladder, rectum as well as mucosal surface points. Dosimetry for Syed plans was calculated for PTV700 cGy coverage. Patients were followed for treatment response and toxicity.Results: Dosimetric analysis between MC and SC plans demonstrated increased tumor coverage (PTV700 cGy, with decreased rectal, bladder, and contralateral vaginal mucosa dose in favor of MC. These differences were significant (p<0.05. Comparison of MC and Syed plans demonstrated increased tumor coverage in favor of Syed plans which were not significant (p=0.71. Patients treated with MC had no cancer recurrence or ≥ grade 3 toxicity.Conclusion: Use of MC was efficacious and safe, providing superior coverage of tumor volumes ≤1cm depth compared to SC and comparable to Syed implant. MC avoids excess dose to surrounding organs compared to SC, and potentially less morbidity than Syed implants. For tumors extending ≤1cm depth, use of MC represents an alternative to an interstitial implant.

  1. Risk Analysis of Loblolly Pine Controlled Mass Pollination Program

    Science.gov (United States)

    T.D. Byram; F.E. Bridgwater

    1999-01-01

    The economic success of controlled mass pollination (CMP) depends both upon the value of the genetic gain obtained and the cost per seed. Crossing the best six loblolly pine (Pinus taeda) parents currently available in each deployment region of the Western Gulf Forest Tree Improvement Program will produce seed with an average additional gain in mean...

  2. Multiple-animal MR imaging using a 3T clinical scanner and multi-channel coil for volumetric analysis in a mouse tumor model

    International Nuclear Information System (INIS)

    Mitsuda, Minoru; Yamaguchi, Masayuki; Furuta, Toshihiro; Fujii, Hirofumi; Nabetani, Akira; Hirayama, Akira; Nozaki, Atsushi; Niitsu, Mamoru

    2011-01-01

    Multiple small-animal magnetic resonance (MR) imaging to measure tumor volume may increase the throughput of preclinical cancer research assessing tumor response to novel therapies. We used a clinical scanner and multi-channel coil to evaluate the usefulness of this imaging to assess experimental tumor volume in mice. We performed a phantom study to assess 2-dimensional (2D) geometric distortion using 9-cm spherical and 32-cell (8 x 4 one-cm 2 grids) phantoms using a 3-tesla clinical MR scanner and dedicated multi-channel coil composed of 16 5-cm circular coils. Employing the multi-channel coil, we simultaneously scanned 6 or 8 mice bearing sarcoma 180 tumors. We estimated tumor volume from the sum of the product of tumor area and slice thickness on 2D spin-echo images (repetition time/echo time, 3500/16 ms; in-plane resolution, 0.195 x 0.195 x 1 mm 3 ). After MR acquisition, we excised and weighed tumors, calculated reference tumor volumes from actual tumor weight assuming a density of 1.05 g/cm 3 , and assessed the correlation between the estimated and reference volumes using Pearson's test. Two-dimensional geometric distortion was acceptable below 5% in the 9-cm spherical phantom and in every cell in the 32-cell phantom. We scanned up to 8 mice simultaneously using the multi-channel coil and found 11 tumors larger than 0.1 g in 12 mice. Tumor volumes were 1.04±0.73 estimated by MR imaging and 1.04±0.80 cm 3 by reference volume (average±standard deviation) and highly correlated (correlation coefficient, 0.995; P<0.01, Pearson's test). Use of multiple small-animal MR imaging employing a clinical scanner and multi-channel coil enabled accurate assessment of experimental tumor volume in a large number of mice and may facilitate high throughput monitoring of tumor response to therapy in preclinical research. (author)

  3. Low bone mass prevalence and osteoporosis risk factor assessment in African American Wisconsin women.

    Science.gov (United States)

    Kidambi, Srividya; Partington, Susan; Binkley, Neil

    2005-11-01

    Post-menopausal osteoporosis is seen in all racial groups. With the increasing population and longevity of minority groups, osteoporosis is becoming an important health concern. Data regarding risk factors for, and prevalence of, low bone mass and awareness of osteoporosis risk in African American (AA) women are limited. This article evaluates the risk factors for, and prevalence of, low bone mass in a population of urban AA women in Wisconsin and assesses this group's perceived risk for osteoporosis. One hundred fifty consecutive community-dwelling AA women > or = 45 years old from Milwaukee, Wis were asked to complete a questionnaire based on currently accepted osteoporosis risk factors. Additionally, their perception of osteoporosis risk was assessed using a Likert scale. All subjects underwent quantitative calcaneal ultrasound. Subject mean age was 54 +/- 7 years. Mean T- and Z-scores were 0.5 and 0.4, respectively. Applying World Health Organization criteria, osteopenia (bone mineral density T-score 2 children), postmenopausal state, and current smoking were associated with lower calcaneal bone mass. Higher education and presence of diabetes were associated with a higher bone mass. Only 25% of the women surveyed thought they were at moderate to high risk for osteoporosis. Low bone mass was present in 33% of these AA women despite their relative young age. Many AA women do not perceive osteoporosis as a health risk. It is necessary to develop strategies to educate AA women regarding osteoporosis risk.

  4. [Association between fat mass index and fat-free mass index values and cardiovascular risk in adolescents].

    Science.gov (United States)

    de Oliveira, Patrícia Morais; da Silva, Fabiana Almeida; Souza Oliveira, Renata Maria; Mendes, Larissa Loures; Netto, Michele Pereira; Cândido, Ana Paula Carlos

    2016-01-01

    To describe the association between fat mass index and fat-free mass index values and factors associated with cardiovascular risk in adolescents in the city of Juiz de Fora, Minas Gerais. Cross-sectional study with 403 adolescents aged 10-14 years, from public and private schools. Anthropometric, clinical, biochemical measurements were obtained, as well as self-reported time spent performing physical exercises, sedentary activities and sexual maturation stage. Regarding the nutritional status; 66.5% of the adolescents had normal weight; 19.9% were overweight and 10.2% were obese. For both genders, the fat mass index was higher in adolescents that had high serum triglycerides, body mass index and waist circumference. Adolescents that had anthropometric, clinical and biochemical characteristics considered to be of risk for the development of cardiovascular disease had higher values of fat mass index. Different methodologies for the assessment of body composition make health promotion and disease prevention more effective. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. Redundancy or heterogeneity in the electric activity of the biceps brachii muscle? Added value of PCA-processed multi-channel EMG muscle activation estimates in a parallel-fibered muscle

    NARCIS (Netherlands)

    Staudenmann, D.; Stegeman, D.F.; van Dieen, J.H.

    2013-01-01

    Conventional bipolar EMG provides imprecise muscle activation estimates due to possibly heterogeneous activity within muscles and due to improper alignment of the electrodes with the muscle fibers. Principal component analysis (PCA), applied on multi-channel monopolar EMG yielded substantial

  6. Body mass index influences prostate cancer risk at biopsy in Japanese men.

    Science.gov (United States)

    Masuda, Hitoshi; Kagawa, Makoto; Kawakami, Satoru; Numao, Noboru; Matsuoka, Yoh; Yokoyama, Minato; Yamamoto, Shinya; Yonese, Junji; Fukui, Iwao; Kihara, Kazunori

    2013-07-01

    To determine the relationship between body mass index and prostate cancer risk at biopsy in Japanese men, and to compared the risk with that of Caucasian men. We retrospectively evaluated 3966 men with prostate-specific antigen levels from 2.5 to 19.9 ng/mL who underwent an initial extended prostate biopsy. Using logistic regression, odds ratios of each body mass index category for risk of prostate cancer and high-grade disease (Gleason score ≥4 + 3) were estimated after controlling for age, prostate-specific antigen, %free prostate-specific antigen, prostate volume, digital rectal examination findings, family history of prostate cancer and the number of biopsy cores. Patients were divided into six categories according to their body mass index (kg/m(2) ) as follows: body mass index and prostate cancer risk at biopsy, with an increased risk observed in men whose body mass index was ≥27.0 compared with the reference group. A significantly increased risk starting at body mass index ≥25.0 was found in high-grade disease. In contrast to our results, there has been no reported increase in the risk of prostate cancer at biopsy in Caucasians within the overweight range (body mass index of 25.0-29.9 based on World Health Organization classification). Japanese men within the overweight body mass index range who have an elevated prostate-specific antigen level also have a significant risk of harboring prostate cancer, especially high-grade disease. Overweight Japanese might be at greater prostate cancer risk at biopsy than overweight Caucasians. © 2012 The Japanese Urological Association.

  7. The effect of elevated body mass index on ischemic heart disease risk

    DEFF Research Database (Denmark)

    Nordestgaard, Børge G; Palmer, Tom M; Benn, Marianne

    2012-01-01

    Adiposity, assessed as elevated body mass index (BMI), is associated with increased risk of ischemic heart disease (IHD); however, whether this is causal is unknown. We tested the hypothesis that positive observational associations between BMI and IHD are causal.......Adiposity, assessed as elevated body mass index (BMI), is associated with increased risk of ischemic heart disease (IHD); however, whether this is causal is unknown. We tested the hypothesis that positive observational associations between BMI and IHD are causal....

  8. Cost-effectiveness and radiological risk associated with mass chest screening

    International Nuclear Information System (INIS)

    Stieve, F.E.

    1987-01-01

    This report presents in summary the cost effectiveness and radiological risks associated with mass chest tuberculosis screening in major European countries. The state of tuberculosis in west Europe, the cost effectiveness of mass screening, international standards regarding radiation doses as well as the need for quality control are addressed

  9. Body mass index and risk of Alzheimer's disease

    DEFF Research Database (Denmark)

    Nordestgaard, Liv Tybjærg; Tybjærg-Hansen, Anne; Nordestgaard, Børge G.

    2017-01-01

    between low BMI and high risk of Alzheimer's disease. Design, Setting, and Participants: Using a Mendelian randomization approach, we studied 95,578 individuals from the Copenhagen General Population Study (CGPS) with up to 36 years of follow-up and consortia data on 303,958 individuals from the Genetic...... Investigation of Anthropometric Traits (GIANT) and the International Genomics of Alzheimer's Project (IGAP). Main Outcome Measure: Risk of Alzheimer's disease. Results: The causal odds ratio for a 1-kg/m2 genetically determined lower BMI was 0.98 [95% confidence interval (CI), 0.77 to 1.23] for a weighted...... allele score in the CGPS. Using 32 BMIdecreasing variants from GIANT and IGAP the causal odds ratio for Alzheimer's disease for a 1-standard deviation (SD) lower genetically determined BMI was 1.02 (95% CI, 0.86 to 1.22). Corresponding observational hazard ratios from the CGPS were 1.07 (95% CI, 1...

  10. GIFT-Grab: Real-time C++ and Python multi-channel video capture, processing and encoding API

    Directory of Open Access Journals (Sweden)

    Dzhoshkun Ismail Shakir

    2017-10-01

    Full Text Available GIFT-Grab is an open-source API for acquiring, processing and encoding video streams in real time. GIFT-Grab supports video acquisition using various frame-grabber hardware as well as from standard-compliant network streams and video files. The current GIFT-Grab release allows for multi-channel video acquisition and encoding at the maximum frame rate of supported hardware – 60 frames per second (fps. GIFT-Grab builds on well-established highly configurable multimedia libraries including FFmpeg and OpenCV. GIFT-Grab exposes a simplified high-level API, aimed at facilitating integration into client applications with minimal coding effort. The core implementation of GIFT-Grab is in C++11. GIFT-Grab also features a Python API compatible with the widely used scientific computing packages NumPy and SciPy. GIFT-Grab was developed for capturing multiple simultaneous intra-operative video streams from medical imaging devices. Yet due to the ubiquity of video processing in research, GIFT-Grab can be used in many other areas. GIFT-Grab is hosted and managed on the software repository of the Centre for Medical Image Computing (CMIC at University College London, and is also mirrored on GitHub. In addition it is available for installation from the Python Package Index (PyPI via the pip installation tool. Funding statement: This work was supported through an Innovative Engineering for Health award by the Wellcome Trust [WT101957], the Engineering and Physical Sciences Research Council (EPSRC [NS/A000027/1] and a National Institute for Health Research Biomedical Research Centre UCLH/UCL High Impact Initiative. Sébastien Ourselin receives funding from the EPSRC (EP/H046410/1, EP/J020990/1, EP/K005278 and the MRC (MR/J01107X/1. Luis C. García-Peraza-Herrera is supported by the EPSRC-funded UCL Centre for Doctoral Training in Medical Imaging (EP/L016478/1.

  11. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  12. Multi-channel WDM RZ-to-NRZ format conversion at 50 Gbit/s based on single silicon microring resonator

    DEFF Research Database (Denmark)

    Ding, Yunhong; Peucheret, Christophe; Pu, Minhao

    2010-01-01

    We comprehensively analyze multiple WDM channels RZ-to- NRZ format conversion using a single microring resonator. The scheme relies on simultaneous suppression of the first order harmonic components in the spectra of all the RZ channels. An optimized silicon microring resonator with free spectral...... range of 100 GHz and Q value of 7900 is designed and fabricated for this purpose. Multi-channel RZ-to-NRZ format conversion is demonstrated experimentally at 50 Gbit/s for WDM channels with 200 GHz channel spacing using the fabricated device. Bit error rate (BER)measurements show very good conversion...

  13. On the Efficiency of the Multi-Channel Analysis of Surface Wave Method for Shallow and Semi-Deep Loose Soil Layers

    Directory of Open Access Journals (Sweden)

    Kasgin Khaheshi Banab

    2010-01-01

    Full Text Available The multi-channel analysis of surface waves (MASWs method was used to obtain the shear wave velocity variations through near surface (depth 2,300 m/s is very large. The MASW velocity results compared with those of other geophysical approaches, such as seismic reflection/refraction methods and borehole data, where available, mostly confirming the capability of the MASW method to distinguish the high shear wave velocity contrast in the study area. We have found that, of the inversion procedures of MASW data, the random search inversion technique provides better results than the analytical generalized inversion method.

  14. Risk and protective factors for mental health at a youth mass gathering.

    Science.gov (United States)

    Cruwys, Tegan; Saeri, Alexander K; Radke, Helena R M; Walter, Zoe C; Crimston, Daniel; Ferris, Laura J

    2018-05-11

    Mass gatherings are well-documented for their public health risks; however, little research has examined their impact on mental health or focused on young people specifically. This study explores risk and protective factors for mental health at mass gatherings, with a particular focus on characterising attendees with high levels of psychological distress and risk taking. Data collection was conducted in situ at "Schoolies", an annual informal week-long mass gathering of approximately 30,000 Australian school leavers. Participants were 812 attendees of Schoolies on the Gold Coast in 2015 or 2016 (74% aged 17 years old). In both years, attendee mental health was found to be significantly better than population norms for their age peers. Identification with the mass gathering predicted better mental health, and this relationship became stronger across the course of the mass gathering. Attendees with high levels of psychological distress were more likely to be male, socially isolated, impulsive, and in a friendship group where risk taking was normative. Mass gatherings may have a net benefit for attendee mental health, especially for those attendees who are subjectively committed to the event. However, a vulnerable subgroup of attendees requires targeted mental health support.

  15. Body mass index predicts risk for complications from transtemporal cerebellopontine angle surgery.

    Science.gov (United States)

    Mantravadi, Avinash V; Leonetti, John P; Burgette, Ryan; Pontikis, George; Marzo, Sam J; Anderson, Douglas

    2013-03-01

    To determine the relationship between body mass index (BMI) and risk for specific complications from transtemporal cerebellopontine angle (CPA) surgery for nonmalignant disease. Case series with chart review. Tertiary-care academic hospital. Retrospective review of 134 consecutive patients undergoing transtemporal cerebellopontine angle surgery for nonmalignant disease from 2009 to 2011. Data were collected regarding demographics, body mass index, intraoperative details, hospital stay, and complications including cerebrospinal fluid leak, wound complications, and brachial plexopathy. One hundred thirty-four patients were analyzed with a mean preoperative body mass index of 28.58. Statistical analysis demonstrated a significant difference in body mass index between patients with a postoperative cerebrospinal fluid leak and those without (P = .04), as well as a similar significant difference between those experiencing postoperative brachial plexopathy and those with no such complication (P = .03). Logistical regression analysis confirmed that body mass index is significant in predicting both postoperative cerebrospinal fluid leak (P = .004; odds ratio, 1.10) and brachial plexopathy (P = .04; odds ratio, 1.07). Elevated body mass index was not significant in predicting wound complications or increased hospital stay beyond postoperative day 3. Risk of cerebrospinal fluid leak and brachial plexopathy is increased in patients with elevated body mass index undergoing surgery of the cerebellopontine angle. Consideration should be given to preoperative optimization via dietary and lifestyle modifications as well as intraoperative somatosensory evoked potential monitoring of the brachial plexus to decrease these risks.

  16. Multi-channel ground-penetrating radar to explore spatial variations in thaw depth and moisture content in the active layer of a permafrost site

    Directory of Open Access Journals (Sweden)

    U. Wollschläger

    2010-08-01

    Full Text Available Multi-channel ground-penetrating radar (GPR was applied at a permafrost site on the Tibetan Plateau to investigate the influence of surface properties and soil texture on the late-summer thaw depth and average soil moisture content of the active layer. Measurements were conducted on an approximately 85 × 60 m2 sized area with surface and soil textural properties that ranged from medium to coarse textured bare soil to finer textured, sparsely vegetated areas covered with fine, wind blown sand, and it included the bed of a gravel road. The survey allowed a clear differentiation of the various units. It showed (i a shallow thaw depth and low average soil moisture content below the sand-covered, vegetated area, (ii an intermediate thaw depth and high average soil moisture content along the gravel road, and (iii an intermediate to deep thaw depth and low to intermediate average soil moisture content in the bare soil terrain. From our measurements, we found hypotheses for the permafrost processes at this site leading to the observed late-summer thaw depth and soil moisture conditions. The study clearly indicates the complicated interactions between surface and subsurface state variables and processes in this environment. Multi-channel GPR is an operational technology to efficiently study such a system at scales varying from a few meters to a few kilometers.

  17. Development of slew-rate-limited time-over-threshold (ToT) ASIC for a multi-channel silicon-based ion detector

    Science.gov (United States)

    Uenomachi, M.; Orita, T.; Shimazoe, K.; Takahashi, H.; Ikeda, H.; Tsujita, K.; Sekiba, D.

    2018-01-01

    High-resolution Elastic Recoil Detection Analysis (HERDA), which consists of a 90o sector magnetic spectrometer and a position-sensitive detector (PSD), is a method of quantitative hydrogen analysis. In order to increase sensitivity, a HERDA system using a multi-channel silicon-based ion detector has been developed. Here, as a parallel and fast readout circuit from a multi-channel silicon-based ion detector, a slew-rate-limited time-over-threshold (ToT) application-specific integrated circuit (ASIC) was designed, and a new slew-rate-limited ToT method is proposed. The designed ASIC has 48 channels and each channel consists of a preamplifier, a slew-rate-limited shaping amplifier, which makes ToT response linear, and a comparator. The measured equivalent noise charges (ENCs) of the preamplifier, the shaper, and the ToT on no detector capacitance were 253±21, 343±46, and 560±56 electrons RMS, respectively. The spectra from a 241Am source measured using a slew-rate-limited ToT ASIC are also reported.

  18. Vehicle mass and injury risk in two-car crashes: A novel methodology.

    Science.gov (United States)

    Tolouei, Reza; Maher, Mike; Titheridge, Helena

    2013-01-01

    This paper introduces a novel methodology based on disaggregate analysis of two-car crash data to estimate the partial effects of mass, through the velocity change, on absolute driver injury risk in each of the vehicles involved in the crash when absolute injury risk is defined as the probability of injury when the vehicle is involved in a two-car crash. The novel aspect of the introduced methodology is in providing a solution to the issue of lack of data on the speed of vehicles prior to the crash, which is required to calculate the velocity change, as well as a solution to the issue of lack of information on non-injury two-car crashes in national accident data. These issues have often led to focussing on relative measures of injury risk that are not independent of risk in the colliding cars. Furthermore, the introduced methodology is used to investigate whether there is any effect of vehicle size above and beyond that of mass ratio, and whether there are any effects associated with the gender and age of the drivers. The methodology was used to analyse two-car crashes to investigate the partial effects of vehicle mass and size on absolute driver injury risk. The results confirmed that in a two-car collision, vehicle mass has a protective effect on its own driver injury risk and an aggressive effect on the driver injury risk of the colliding vehicle. The results also confirmed that there is a protective effect of vehicle size above and beyond that of vehicle mass for frontal and front to side collisions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Reevaluation of benefit and risk of mass screening for stomach cancer

    International Nuclear Information System (INIS)

    Iinuma, Takeshi; Tateno, Yukio

    1990-01-01

    Mass screening for stomach cancer has been performed widely because of the the most prevalent malignancy in Japan. Since X-ray diagnosis is used in stomach cancer screening, the risk of X-ray exposure must be considered by comparing the benefit of mass screening. We have reported in the previous article in 1977 that the benefit and risk of stomach cancer mass screening become equal at the age of 40 yr. Since then, various conditions of the mass screening for stomach cancer have changed so that reevaluation of the benefit and risk relationship is necessary. The risk coefficient of radiation-induced stomach cancer has been revised drastically in the report of United Nations Scientific Committee on the effects of radiation in 1988. In this report, the benefit of mass screening of stomach cancer is defined as the net elongation of average life expectancy due to the life saved, and the risk of the screening is defined as the net shortage of average life expectancy due to the radiation-induced stomach cancer and leukemia. Since the benefit increases rapidly and the risk decreases with age, an appropriate age when the benefit and risk become identical is required, and under this age the mass screening is not justified to be performed. Assuming X-ray dose equivalent to stomach of 10 mSv and risk coefficient of stomach cancer of 12.6x10 -3 Sv -1 from the United Nations report, the critical age is found to be about 35 yr. for men and women. It is strongly recommended that the dose equivalent should be lowered less than 5 mSv. In a calculation of the risk of endoscopic examination in mass screening using reported figures of fatal accident (1.6x10 -5 ) and severe injury (48x10 -5 ) of the stomach endoscopic examination, the critical ages are found to be 40 yr for men and 45 yr for women which are higher than those with X-rays. A screening test using stomach endoscopy cannot be accepted. (J.P.N.)

  20. Cumulative Mass and NIOSH Variable Lifting Index Method for Risk Assessment: Possible Relations.

    Science.gov (United States)

    Stucchi, Giulia; Battevi, Natale; Pandolfi, Monica; Galinotti, Luca; Iodice, Simona; Favero, Chiara

    2018-02-01

    Objective The aim of this study was to explore whether the Variable Lifting Index (VLI) can be corrected for cumulative mass and thus test its efficacy in predicting the risk of low-back pain (LBP). Background A validation study of the VLI method was published in this journal reporting promising results. Although several studies highlighted a positive correlation between cumulative load and LBP, cumulative mass has never been considered in any of the studies investigating the relationship between manual material handling and LBP. Method Both VLI and cumulative mass were calculated for 2,374 exposed subjects using a systematic approach. Due to high variability of cumulative mass values, a stratification within VLI categories was employed. Dummy variables (1-4) were assigned to each class and used as a multiplier factor for the VLI, resulting in a new index (VLI_CMM). Data on LBP were collected by occupational physicians at the study sites. Logistic regression was used to estimate the risk of acute LBP within levels of risk exposure when compared with a control group formed by 1,028 unexposed subjects. Results Data showed greatly variable values of cumulative mass across all VLI classes. The potential effect of cumulative mass on damage emerged as not significant ( p value = .6526). Conclusion When comparing VLI_CMM with raw VLI, the former failed to prove itself as a better predictor of LBP risk. Application To recognize cumulative mass as a modifier, especially for lumbar degenerative spine diseases, authors of future studies should investigate potential association between the VLI and other damage variables.

  1. Predictive value of body mass index to metabolic syndrome risk factors in Syrian adolescents.

    Science.gov (United States)

    Al-Bachir, Mahfouz; Bakir, Mohamad Adel

    2017-06-25

    Obesity has become a serious epidemic health problem in both developing and developed countries. There is much evidence that obesity among adolescents contributed significantly to the development of type 2 diabetes and coronary heart disease in adulthood. Very limited information exists on the prevalence of overweight, obesity, and associated metabolic risk factors among Syrian adolescents. Therefore, the purpose of this study was to determine the relationship between obesity determined by body mass index and the major metabolic risk factors among Syrian adolescents. A cross-sectional study of a randomly selected sample of 2064 apparently healthy Syrian adolescents aged 18 to 19 years from Damascus city, in Syria, was performed. Body mass index and blood pressure were measured. Serum concentrations of glucose, triglycerides, total cholesterol, high-density lipoprotein-cholesterol, and low-density lipoprotein-cholesterol were determined. Metabolic syndrome was defined using the national criteria for each determined metabolic risk factor. Individuals with a body mass index 25 to 29.9 were classified as overweight, whereas individuals with a body mass index ≥30 were classified as obese. A receiver operating characteristics curve was drawn to determine appropriate cut-off points of the body mass index for defining overweight and obesity, and to indicate the performance of body mass index as a predictor of risk factors. The obtained data showed that blood pressure and the overall mean concentrations of fasting blood sugar, triglycerides, cholesterol, low-density lipoprotein-cholesterol, and triglycerides/high-density lipoprotein-cholesterol were significantly higher in overweight and obese adolescent groups (p index and some metabolic risks, the data suggest the best body mass index cut-offs ranged between 23.25 and 24.35 kg/m 2 . A strong association between overweight and obesity as determined by body mass index and high concentrations of metabolic syndrome

  2. Multi-DSP and FPGA based Multi-channel Direct IF/RF Digital receiver for atmospheric radar

    Science.gov (United States)

    Yasodha, Polisetti; Jayaraman, Achuthan; Kamaraj, Pandian; Durga rao, Meka; Thriveni, A.

    2016-07-01

    Modern phased array radars depend highly on digital signal processing (DSP) to extract the echo signal information and to accomplish reliability along with programmability and flexibility. The advent of ASIC technology has made various digital signal processing steps to be realized in one DSP chip, which can be programmed as per the application and can handle high data rates, to be used in the radar receiver to process the received signal. Further, recent days field programmable gate array (FPGA) chips, which can be re-programmed, also present an opportunity to utilize them to process the radar signal. A multi-channel direct IF/RF digital receiver (MCDRx) is developed at NARL, taking the advantage of high speed ADCs and high performance DSP chips/FPGAs, to be used for atmospheric radars working in HF/VHF bands. Multiple channels facilitate the radar t be operated in multi-receiver modes and also to obtain the wind vector with improved time resolution, without switching the antenna beam. MCDRx has six channels, implemented on a custom built digital board, which is realized using six numbers of ADCs for simultaneous processing of the six input signals, Xilinx vertex5 FPGA and Spartan6 FPGA, and two ADSPTS201 DSP chips, each of which performs one phase of processing. MCDRx unit interfaces with the data storage/display computer via two gigabit ethernet (GbE) links. One of the six channels is used for Doppler beam swinging (DBS) mode and the other five channels are used for multi-receiver mode operations, dedicatedly. Each channel has (i) ADC block, to digitize RF/IF signal, (ii) DDC block for digital down conversion of the digitized signal, (iii) decoding block to decode the phase coded signal, and (iv) coherent integration block for integrating the data preserving phase intact. ADC block consists of Analog devices make AD9467 16-bit ADCs, to digitize the input signal at 80 MSPS. The output of ADC is centered around (80 MHz - input frequency). The digitized data is fed

  3. Childhood body mass index and height and risk of histologic subtypes of endometrial cancer

    DEFF Research Database (Denmark)

    Aarestrup, J.; Gamborg, M.; Ulrich, L. G.

    2016-01-01

    BACKGROUND: Endometrial cancer risk factors include adult obesity and taller stature, but the influence of size earlier in life is incompletely understood. We examined whether childhood body mass index (BMI; kg m(-2)) and height were associated with histologic subtypes of endometrial cancer...

  4. Parent/Student Risk and Protective Factors in Understanding Early Adolescent's Body Mass Index

    Science.gov (United States)

    Fitzpatrick, Kevin M.; Willis, Don

    2016-01-01

    This article's aim is to examine correlates of middle school students' body mass index (BMI). Little research simultaneously has considered both child and parent correlates in predicting child's BMI; we examine the interrelationships between middle school students and their parent's risks and protective factors and their impact on the child's BMI.…

  5. Risk-benefit analysis for mass screening of breast cancer utilizing mammography as a screening test

    International Nuclear Information System (INIS)

    Iinuma, T.A.; Tateno, Yukio

    1989-01-01

    Incidence of breast cancers in Japanese women is increasing steadily. Mass screening of breast cancer was started in Japan under auspices of Adult Health Promotion Act of the Japanese Government from 1987. As the first screening method, the palpation of breasts is employed at present, but it is expected to be replaced by the mammography. In this report, the risk-benefit analysis is presented between risk of breast carcinogenesis due to radiation and benefit of mass screening of breast cancer. The benefit of mass screening is taken as the net elongation of average life expectancy of women due to survival from breast cancers. The risk of mammography is taken as the net loss of average life expectancy of women due to breast carcinogenesis. In the latter, the latency time and plateau period of radiation carcinogenesis were taken into consideration in the calculation. The results show that the ages at which the benefit and risk become equal are between 30 and 35 years old when dose equivalent of mammography is between 10 and 20 mSv, that are conventionally used. However, the critical age will be reduced to 20 years old if the dose equivalent becomes 1 mSv. Therefore, it is strongly recommended that a low dose mammographic system should be developed in order to achieve 1 mSv for the mass screening of breast cancer of Japanese women. In author's opinion, this is quite feasible by employing a new digital radiography with imaging plate. (author)

  6. [Mass media influence and risk of developing eating disorders in female students from Lima, Peru].

    Science.gov (United States)

    Lazo Montoya, Yessenia; Quenaya, Alejandra; Mayta-Tristán, Percy

    2015-12-01

    Eating disorders (EDs) are a public health problem, and their relationship to mass media is still controversial. To assess whether there is an association between models of body image shown in mass media and the risk of developing EDs among female adolescent students from Lima, Peru. Cross-sectional study conducted in three schools located in the district of La Victoria, Lima, Peru. The risk of developing EDs was measured using the Eating Attitudes Test-26 (EAT-26), while mass media influence was measured using the Sociocultural Attitudes Towards Appearance Questionnaire-3 (SATAQ-3), which was categorized into tertiles both in the overall score and its subscales (information, pressure, general internalization, and athletic internalization). Adjusted prevalence ratios (aPR) for EDs were estimated. Four hundred and eighty-three students were included, their median age was 14 ? 3 years old. A risk of developing an ED was observed in 13.9% of them. Students who are more influenced by mass media (upper tertile of the SATAQ-3) have a higher probability of having a risk of developing an ED (aPR: 4.24; 95% confidence interval |-CI-|: 2.10-8.56), as well as those who have a greater access to information (PR: 1.89; 95% CI: 1.09-3.25), suffer more pressure (PR: 4.97; 95% CI: 2.31-10.69), show a greater general internalization (PR: 5.00; 95% CI: 2.39-10.43), and show a greater level of athletic internalization (PR: 4.35; 95% CI: 2.19-8-66). The greater the influence of mass media, the greater the probability of having a risk of developing an ED among female students from Lima, Peru.

  7. Familial psychosocial risk classes and preschooler body mass index: The moderating effect of caregiver feeding style.

    Science.gov (United States)

    Horodynski, Mildred A; Brophy-Herb, Holly E; Martoccio, Tiffany L; Contreras, Dawn; Peterson, Karen; Shattuck, Mackenzie; Senehi, Neda; Favreau, Zachary; Miller, Alison L; Sturza, Julie; Kaciroti, Niko; Lumeng, Julie C

    2018-04-01

    Early child weight gain predicts adolescent and adult obesity, underscoring the need to determine early risk factors affecting weight status and how risk factors might be mitigated. Socioeconomic status, food insecurity, caregiver depressive symptomology, single parenthood, and dysfunctional parenting each have been linked to early childhood weight status. However, the associations between these risk factors and children's weight status may be moderated by caregiver feeding styles (CFS). Examining modifiable factors buffering risk could provide key information to guide early obesity intervention efforts. This analysis used baseline data from the Growing Healthy project that recruited caregivers/child dyads (N = 626) from Michigan Head Start programs. Caregivers were primarily non-Hispanic white (62%) and African American (30%). After using latent class analysis to identify classes of familial psychosocial risk, CFS was tested as a moderator of the association between familial psychosocial risk class and child body mass index (BMI) z-score. Latent class analysis identified three familial psychosocial risk classes: (1) poor, food insecure and depressed families; (2) poor, single parent families; and (3) low risk families. Interactive effects for uninvolved feeding styles and risk group indicated that children in poor, food insecure, and depressed families had higher BMI z-scores compared to children in the low risk group. Authoritative feeding styles in low risk and poor, food insecure, and depressed families showed lower child BMI z-scores relative to poor, single parent families with authoritative feeding styles. Uninvolved feeding styles intensified the risk and an authoritative feeding style muted the risk conferred by living in a poor, food-insecure, and depressed family. Interventions that promote responsive feeding practices could help decrease the associations of familial psychosocial risks with early child weight outcomes. Copyright © 2017 Elsevier Ltd

  8. Mendelian Randomization Study of Body Mass Index and Colorectal Cancer Risk

    DEFF Research Database (Denmark)

    Thrift, Aaron P.; Gong, Jian; Peters, Ulrike

    2015-01-01

    Background: High body mass index (BMI) is consistently linked to increased risk of colorectal cancer for men, whereas the association is less clear for women. As risk estimates from observational studies may be biased and/or confounded, we conducted a Mendelian randomization study to estimate...... the causal association between BMI and colorectal cancer. Methods: We used data from 10,226 colorectal cancer cases and 10,286 controls of European ancestry. The Mendelian randomization analysis used a weighted genetic risk score, derived from 77 genome-wide association study–identified variants associated......, rather than overall obesity, is a more important risk factor for men requires further investigation. Impact: Overall, conventional epidemiologic and Mendelian randomization studies suggest a strong association between obesity and the risk of colorectal cancer....

  9. A simple and highly selective 2,2-diferrocenylpropane-based multi-channel ion pair receptor for Pb(2+) and HSO4(-).

    Science.gov (United States)

    Wan, Qian; Zhuo, Ji-Bin; Wang, Xiao-Xue; Lin, Cai-Xia; Yuan, Yao-Feng

    2015-03-28

    A structurally simple, 2,2-diferrocenylpropane-based ion pair receptor 1 was synthesized and characterized by (1)H NMR, (13)C NMR, HRMS, elemental analyses, and single-crystal X-ray diffraction. The ion pair receptor 1 showed excellent selectivity and sensitivity towards Pb(2+) with multi-channel responses: a fluorescence enhancement (more than 42-fold), a notable color change from yellow to red, redox anodic shift (ΔE1/2 = 151 mV), while HSO4(-) promoted fluorescence enhancement when Pb(2+) or Zn(2+) was bonded to the cation binding-site. (1)H NMR titration and density functional theory were performed to reveal the sensing mechanism based on photo-induced electron transfer (PET).

  10. The investigation of multi-channel splitters and big-bend waveguides based on 2D sunflower-typed photonic crystals

    Science.gov (United States)

    Liu, Wei; Sun, XiaoHong; Fan, QingBin; Wang, Shuai; Qi, YongLe

    2016-12-01

    Different kinds of multi-channel splitters and big-bend waveguides have been designed and investigated by using sunflower-typed photonic crystals. By comparing the transmission spectra of two kinds of 4-channels beam splitters, we find that "C" type splitter has a relative uniform splitting ratio for different channels in a certain wavelength range. Furthermore three types of waveguides with different bending degrees have been investigated. Except for a little loss in the short wavelength with the increase of the bending degrees, they have almost the same transmission spectra structures. The result can be extended to big-bend waveguides with arbitrary bending degrees. This research is valuable for developing new-typed integrated optical communication devices.

  11. Encoding of rat working memory by power of multi-channel local field potentials via sparse non-negative matrix factorization

    Institute of Scientific and Technical Information of China (English)

    Xu Liu; Tiao-Tiao Liu; Wen-Wen Bai; Hu Yi; Shuang-Yan Li; Xin Tian

    2013-01-01

    Working memory plays an important role in human cognition.This study investigated how working memory was encoded by the power of multi-channel local field potentials (LFPs) based on sparse nonnegative matrix factorization (SNMF).SNMF was used to extract features from LFPs recorded from the prefrontal cortex of four Sprague-Dawley rats during a memory task in a Y maze,with 10 trials for each rat.Then the power-increased LFP components were selected as working memory-related features and the other components were removed.After that,the inverse operation of SNMF was used to study the encoding of working memory in the timefrequency domain.We demonstrated that theta and gamma power increased significantly during the working memory task.The results suggested that postsynaptic activity was simulated well by the sparse activity model.The theta and gamma bands were meaningful for encoding working memory.

  12. Experimental and theoretical study of hydrodynamic cell lysing of cancer cells in a high-throughput Circular Multi-Channel Microfiltration device

    KAUST Repository

    Ma, W.

    2013-04-01

    Microfiltration is an important microfluidic technique suitable for enrichment and isolation of cells. However, cell lysing could occur due to hydrodynamic damage that may be detrimental for medical diagnostics. Therefore, we conducted a systematic study of hydrodynamic cell lysing in a high-throughput Circular Multi-Channel Microfiltration (CMCM) device integrated with a polycarbonate membrane. HeLa cells (cervical cancer cells) were driven into the CMCM at different flow rates. The viability of the cells in the CMCM was examined by fluorescence microscopy using Acridine Orange (AO)/Ethidium Bromide (EB) as a marker for viable/dead cells. A simple analytical cell viability model was derived and a 3D numerical model was constructed to examine the correlation of between cell lysing and applied shear stress under varying flow rate and Reynolds number. The measured cell viability as a function of the shear stress was consistent with theoretical and numerical predictions when accounting for cell size distribution. © 2013 IEEE.

  13. Experimental and theoretical study of hydrodynamic cell lysing of cancer cells in a high-throughput Circular Multi-Channel Microfiltration device

    KAUST Repository

    Ma, W.; Liu, D.; Shagoshtasbi, H.; Shukla, A.; Nugroho, E. S.; Zohar, Y.; Lee, Y.-K.

    2013-01-01

    Microfiltration is an important microfluidic technique suitable for enrichment and isolation of cells. However, cell lysing could occur due to hydrodynamic damage that may be detrimental for medical diagnostics. Therefore, we conducted a systematic study of hydrodynamic cell lysing in a high-throughput Circular Multi-Channel Microfiltration (CMCM) device integrated with a polycarbonate membrane. HeLa cells (cervical cancer cells) were driven into the CMCM at different flow rates. The viability of the cells in the CMCM was examined by fluorescence microscopy using Acridine Orange (AO)/Ethidium Bromide (EB) as a marker for viable/dead cells. A simple analytical cell viability model was derived and a 3D numerical model was constructed to examine the correlation of between cell lysing and applied shear stress under varying flow rate and Reynolds number. The measured cell viability as a function of the shear stress was consistent with theoretical and numerical predictions when accounting for cell size distribution. © 2013 IEEE.

  14. Biphasic DC measurement approach for enhanced measurement stability and multi-channel sampling of self-sensing multi-functional structural materials doped with carbon-based additives

    Science.gov (United States)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon; Geiger, Randall

    2017-06-01

    Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real

  15. Closed-Loop Neuroprosthesis for Reach-to-Grasp Assistance: Combining Adaptive Multi-channel Neuromuscular Stimulation with a Multi-joint Arm Exoskeleton.

    Science.gov (United States)

    Grimm, Florian; Gharabaghi, Alireza

    2016-01-01

    Stroke patients with severe motor deficits cannot execute task-oriented rehabilitation exercises with their affected upper extremity. Advanced rehabilitation technology may support them in performing such reach-to-grasp movements. The challenge is, however, to provide assistance as needed, while maintaining the participants' commitment during the exercises. In this feasibility study, we introduced a closed-loop neuroprosthesis for reach-to-grasp assistance which combines adaptive multi-channel neuromuscular stimulation with a multi-joint arm exoskeleton. Eighteen severely affected chronic stroke patients were assisted by a gravity-compensating, seven-degree-of-freedom exoskeleton which was attached to the paretic arm for performing reach-to-grasp exercises resembling activities of daily living in a virtual environment. During the exercises, adaptive electrical stimulation was applied to seven different muscles of the upper extremity in a performance-dependent way to enhance the task-oriented movement trajectory. The stimulation intensity was individualized for each targeted muscle and remained subthreshold, i.e., induced no overt support. Closed-loop neuromuscular stimulation could be well integrated into the exoskeleton-based training, and increased the task-related range of motion (p = 0.0004) and movement velocity (p = 0.015), while preserving accuracy. The highest relative stimulation intensity was required to facilitate the grasping function. The facilitated range of motion correlated with the upper extremity Fugl-Meyer Assessment score of the patients (p = 0.028). Combining adaptive multi-channel neuromuscular stimulation with antigravity assistance amplifies the residual motor capabilities of severely affected stroke patients during rehabilitation exercises and may thus provide a customized training environment for patient-tailored support while preserving the participants' engagement.

  16. Closed-Loop Neuroprosthesis for Reach-to-Grasp Assistance: Combining Adaptive Multi-channel Neuromuscular Stimulation with a Multi-joint Arm Exoskeleton

    Science.gov (United States)

    Grimm, Florian; Gharabaghi, Alireza

    2016-01-01

    Stroke patients with severe motor deficits cannot execute task-oriented rehabilitation exercises with their affected upper extremity. Advanced rehabilitation technology may support them in performing such reach-to-grasp movements. The challenge is, however, to provide assistance as needed, while maintaining the participants' commitment during the exercises. In this feasibility study, we introduced a closed-loop neuroprosthesis for reach-to-grasp assistance which combines adaptive multi-channel neuromuscular stimulation with a multi-joint arm exoskeleton. Eighteen severely affected chronic stroke patients were assisted by a gravity-compensating, seven-degree-of-freedom exoskeleton which was attached to the paretic arm for performing reach-to-grasp exercises resembling activities of daily living in a virtual environment. During the exercises, adaptive electrical stimulation was applied to seven different muscles of the upper extremity in a performance-dependent way to enhance the task-oriented movement trajectory. The stimulation intensity was individualized for each targeted muscle and remained subthreshold, i.e., induced no overt support. Closed-loop neuromuscular stimulation could be well integrated into the exoskeleton-based training, and increased the task-related range of motion (p = 0.0004) and movement velocity (p = 0.015), while preserving accuracy. The highest relative stimulation intensity was required to facilitate the grasping function. The facilitated range of motion correlated with the upper extremity Fugl-Meyer Assessment score of the patients (p = 0.028). Combining adaptive multi-channel neuromuscular stimulation with antigravity assistance amplifies the residual motor capabilities of severely affected stroke patients during rehabilitation exercises and may thus provide a customized training environment for patient-tailored support while preserving the participants' engagement. PMID:27445658

  17. Effects on humans elicited by inhaling the fragrance of essential oils: sensory test, multi-channel thermometric study and forehead surface potential wave measurement on basil and peppermint.

    Science.gov (United States)

    Satoh, Tomoko; Sugawara, Yoshiaki

    2003-01-01

    The effects on humans inhaling the fragrance of essential oils were examined in terms of a sensory test, a multi-channel skin thermometer study and a portable forehead surface electroencephalographic (IBVA-EEG) measurement. The essential oils examined in this study were those of basil and peppermint, because our previous sensory test had indicated an opposite effect of these essential oils when mental work was undertaken; the inhalation of basil produced a more favorable impression after work than before work, whereas peppermint produced an unfavorable impression under these circumstances. For subjects administered basil or peppermint before and after mental work using an inhalator, a series of multi-channel skin thermometer studies and IBVA-EEG measurements were conducted. Using such paired odorants, our results showed that when compared between before and after mental work assigned to subjects: (1) the inhalation of basil, in which a favorable impression was predominant on the whole in terms of the sensory evaluation spectrum, was shown to be associated upward tendency in finger-tip skin temperature; (2) whereas these situations were opposite in the case of peppermint, in which the reversed (unfavorable) feature in sensory profiling was accompanied by a decrease in the magnitude of beta waves and a decrease in the finger-tip skin temperature both based on Welch's method, even at p < 0.01, implying a decreasing propensity of the aroused state and of the arousal response. The elucidation of such sensory and physiological endpoints of paired odorants would be of primary importance for human chemoreception science, because these are only rarely recorded during the same experiments, and this paradigm is highly informative about non-verbal responses to odorants.

  18. SU-G-TeP2-07: Dosimetric Characterization of a New HDR Multi-Channel Esophageal Applicator for Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, A; Gao, S; Greskovich, J; Wilkinson, D [Cleveland Clinic, Cleveland, OH (United States); Diener, T [Cleveland State University, Cleveland, OH (United States)

    2016-06-15

    Purpose: To characterize the dose distribution of a new multi-channel esophageal applicator for brachytherapy HDR treatment, and particularly the effect of the presence of air or water in the applicator’s expansion balloon. Methods: A new multi-channel (6) inflatable applicator for esophageal HDR has been developed in house and tested in a simple water phantom. CT image sets were obtained under several balloon expansions (80ml of air, 50 cc of water), and channel loadings and used with the Oncentra (Elekta) planning system based on TG43 formalism. 400 cGy was prescribed to a plane 1cm away from the applicator. Planar dose distributions were measured for that plane and one next to the applicator using Gafchromic EBT3 film and scanned by a Vidar VXR-12 film digitizer. Film and TPS generated dose distributions of film were sent to OmniPro I’mRT (iba DOSIMETRY) for analysis. 2D dose profiles in both X and Y directions were compared and gamma analysis performed. Results: Film dose measurement of the air-inflated applicator is lower than the TPS calculated dose by as much as 60%. Only 80.8% of the pixels passed the gamma criteria (3%/3mm). For the water-inflated applicator, the measured film dose is fairly close to the TPS calculated dose (typically within <3%). 99.84% of the pixels passed the gamma criteria (3%/3mm). Conclusion: TG43 based calculations worked well when water was used in the expansion balloon. However, when air is present in that balloon, the neglect of heterogeneity corrections in the TG43 calculation results in large differences between calculated and measured doses. This could result in severe underdosing when used in a patient. This study illustrates the need for a TPS with an advanced algorithm which can account for heterogeneity. Supported by Innovations Department, Cleveland Clinic.

  19. Reduced but broader prefrontal activity in patients with schizophrenia during n-back working memory tasks: a multi-channel near-infrared spectroscopy study.

    Science.gov (United States)

    Koike, Shinsuke; Takizawa, Ryu; Nishimura, Yukika; Kinou, Masaru; Kawasaki, Shingo; Kasai, Kiyoto

    2013-09-01

    Caudal regions of the prefrontal cortex, including the dorsolateral (DLPFC) and ventrolateral (VLPFC) prefrontal cortex, are involved in essential cognitive functions such as working memory. In contrast, more rostral regions, such as the frontopolar cortex (FpC), have integrative functions among cognitive functions and thereby contribute crucially to real-world social activity. Previous functional magnetic resonance imaging studies have shown patients with schizophrenia had different DLPFC activity pattern in response to cognitive load changes compared to healthy controls; however, the spatial relationship between the caudal and rostral prefrontal activation has not been evaluated under less-constrained conditions. Twenty-six patients with schizophrenia and 26 age-, sex-, and premorbid-intelligence-matched healthy controls participated in this study. Hemodynamic changes during n-back working memory tasks with different cognitive loads were measured using multi-channel near-infrared spectroscopy (NIRS). Healthy controls showed significant task-related activity in the bilateral VLPFC and significant task-related decreased activity in the DLPFC, with greater signal changes when the task required more cognitive load. In contrast, patients with schizophrenia showed activation in the more rostral regions, including bilateral DLPFC and FpC. Neither decreased activity nor greater activation in proportion to elevated cognitive load occurred. This multi-channel NIRS study demonstrated that activation intensity did not increase in patients with schizophrenia associated with cognitive load changes, suggesting hypo-frontality as cognitive impairment in schizophrenia. On the other hand, patients had broader prefrontal activity in areas such as the bilateral DLPFC and FpC regions, thus suggesting a hyper-frontality compensatory response. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Comparison of the Usefulness of four Risk-of-Malignancy Indices using Ultrasonography in Ovarian masses

    International Nuclear Information System (INIS)

    Jo, Moo Sung; Moon, Su Hyun; Joo, Jong Kil; Suh, Dong Soo; Kim, Ki Hyung; Yoon, Man Soo

    2010-01-01

    The aim of this study was to evaluate the usefulness of four Risk-of- Malignancy Indices (RMI) in women with ovarian masses. Between January 2007 and December 2008, 344 women who visited our hospital for surgical exploration due to an ovarian mass were enrolled in this study. Each RMI was based on the combination of menopausal status, ultrasound findings of ovarian masses, and absolute level of serum CA-125. A cutoff level of 200 was chosen as the threshold for determining between malignant and benign ovarian masses in RMI 1, RMI 2, and RMI 3. A cutoff level of 450 was chosen as the threshold in RMI 4. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined. The combination of four malignancy indices is more accurate than menopausal status, ultrasound findings, and serum CA-125 alone, respectively for determining whether a mass is benign or malignant. RMI 1 and RMI 4 were found to be better than RMI 2 and RMI 3. RMI 4 was the most reliable test among them. The relationship between RMI 1 and RMI 4 was not statistically significant. With the cutoff level for RMI 4 at 450, the corresponding, sensitivity, specificity, positive predictive value, and negative predictive value were 72.1%, 88.0%, 56.4%, 93.9%, respectively. All four RMI were reliable tests for determining whether ovarian masses are malignant or benign, and RMI 4 was the most reliable index among them

  1. Adult body mass index and risk of ovarian cancer by subtype

    DEFF Research Database (Denmark)

    Dixon, Suzanne C; Nagle, Christina M; Thrift, Aaron P

    2016-01-01

    BACKGROUND: Observational studies have reported a positive association between body mass index (BMI) and ovarian cancer risk. However, questions remain as to whether this represents a causal effect, or holds for all histological subtypes. The lack of association observed for serous cancers may......, for instance, be due to disease-associated weight loss. Mendelian randomization (MR) uses genetic markers as proxies for risk factors to overcome limitations of observational studies. We used MR to elucidate the relationship between BMI and ovarian cancer, hypothesizing that genetically predicted BMI would...... be associated with increased risk of non-high grade serous ovarian cancers (non-HGSC) but not HGSC. METHODS: We pooled data from 39 studies (14 047 cases, 23 003 controls) in the Ovarian Cancer Association Consortium. We constructed a weighted genetic risk score (GRS, partial F-statistic = 172), summing alleles...

  2. [Childhood body mass index and the risk of coronary heart disease in adulthood

    DEFF Research Database (Denmark)

    Baker, Jennifer Lyn; Olsen, L.W.; Sørensen, Thorkild I.A.

    2008-01-01

    The severity of the long term consequences of the current childhood obesity epidemic on coronary heart disease is unknown. Therefore we investigated the association between body mass index (BMI) at ages 7-13 years and heart disease in adulthood among 276,835 Danish schoolchildren. We found...... that higher BMI during this period of childhood is associated with an increased risk of any, non-fatal and fatal heart disease in adulthood. Worldwide, as children are becoming heavier, our findings suggest that greater numbers of children are at risk of having coronary heart disease in adulthood...

  3. Body mass index, exercise capacity, and mortality risk in male veterans with hypertension.

    Science.gov (United States)

    Faselis, Charles; Doumas, Michael; Panagiotakos, Demosthenes; Kheirbek, Raya; Korshak, Lauren; Manolis, Athanasios; Pittaras, Andreas; Tsioufis, Costas; Papademetriou, Vasilios; Fletcher, Ross; Kokkinos, Peter

    2012-04-01

    Overweight and obesity are associated with increased risk of chronic diseases and mortality. Exercise capacity is inversely associated with mortality risk. However, little is known on the interaction between fitness, fatness, and mortality risk in hypertensive individuals. Thus, we assessed the interaction between exercise capacity, fatness, and all-cause mortality in hypertensive males. A graded exercise test was performed in 4,183 hypertensive veterans (mean age ± s.d.; 63.3 ± 10.5 years) at the Veterans Affairs Medical Center, Washington, DC. We defined three body weight categories based on body mass index (BMI): normal weight (BMI 7.5 METs). During a median follow-up period of 7.2 years, there were 1,000 deaths. The association between exercise capacity and mortality risk was strong, inverse, and graded. For each 1-MET increase in exercise capacity the adjusted risk was 20% for normal weight, 12% for overweight, and 25% for obese (P exercise capacity is associated with lower mortality risk in hypertensive males regardless of BMI. The risk for overweight and obese but fit individuals was significantly lower when compared to normal weight but unfit. These findings suggest that in older hypertensive men, it may be healthier to be fit regardless of standard BMI category than unfit and normal weight.

  4. Electronic drive and acquisition system for mass spectrometry

    Science.gov (United States)

    Schaefer, Rembrandt Thomas (Inventor); Mojarradi, Mohammad (Inventor); Chutjian, Ara (Inventor); Darrach, Murray R. (Inventor); MacAskill, John (Inventor); Tran, Tuan (Inventor); Burke, Gary R. (Inventor); Madzunkov, Stojan M. (Inventor); Blaes, Brent R. (Inventor); Thomas, John L. (Inventor)

    2010-01-01

    The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

  5. Risk-oriented approach application at planning and orginizing antiepidemic provision of mass events

    Directory of Open Access Journals (Sweden)

    D.V. Efremenko

    2017-03-01

    Full Text Available Mass events tend to become more and more dangerous for population health, as they cause various health risks, including infectious pathologies risks. Our research goal was to work out scientifically grounded approaches to assessing and managing epidemiologic risks as well as analyze their application practices implemented during preparation to the Olympics-2014, the Games themselves, as well as other mass events which took place in 2014–2016. We assessed epidemiologic complications risks with the use of diagnostic test-systems and applying a new technique which allowed for mass events peculiarities. The technique is based on infections ranking as per 3 potential danger categories in accordance with created criteria which represented quantitative and qualitative predictive parameters (predictors. Application of risk-oriented approach and multi-factor analysis allowed us to detect exact possible maximum requirements for providing sanitary-epidemiologic welfare in terms of each separate nosologic form. As we enhanced our laboratory base with test-systems to provide specific indication as per accomplished calculations, it enabled us, on one hand, to secure the required preparations, and, on the other hand, to avoid unnecessary expenditures. To facilitate decision-making process during the Olympics-2014 we used an innovative product, namely, a computer program based on geoinformation system (GIS. It helped us to simplify and to accelerate information exchange within the frameworks of intra- and interdepartmental interaction. "Dynamic epidemiologic threshold" was daily calculated for measles, chickenpox, acute enteric infections and acute respiratory viral infections of various etiology. And if it was exceeded or possibility of "epidemiologic spot" for one or several nosologies occurred, an automatic warning appeared in GIS. Planning prevention activities regarding feral herd infections and zoogenous extremely dangerous infections which were endemic

  6. Pre-prepregnancy body mass index and the risk of gestational diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Rudić-Grujić Vesna

    2017-01-01

    Full Text Available Introduction/Objective. Not only do pre-pregnancy overweight or obesity increase the risk of adverse maternal and perinatal outcomes but they also lead to the development of gestational diabetes mellitus. The objective of this study was to estimate the prevalence of pre-pregnancy overweight and obesity in the Republic of Srpska and to investigate its association with hyperglycemia and risk of gestational diabetes mellitus. Methods. A cross-sectional study was carried out during the period from February to October 2012 among 555 pregnant women in gestational period from 24 to 28 weeks. The criterion for exclusion from the sample was previously diagnosed type 1 or type 2 diabetes. Results. Before pregnancy, 20.39% of participants had increased body mass index, while 4.04 % [95% confidence interval (CI; 2.62–6.13] were obese. Gestational diabetes mellitus was diagnosed in 10.91% (95% CI, 8.44–13.98 of them. The increase in body mass index by 1 increased the risk of gestational diabetes mellitus by 1.09 times [odds ratio (OR = 1.09; 95% CI; 1.02–1.16]. Pregnant women who were overweight had a 4.88 times greater risk (OR = 4.88; 95% CI, 1.23–29.41 of developing gestational diabetes. Conclusion. Every fifth pregnant woman in this study was overweight or obese before pregnancy. The increase in body mass index by 1 increased the risk of gestational diabetes by 1.09 times (OR = 1.09; 95% CI; 1.02–1.16. Counselling is necessary for overweight and obese women planning pregnancy.

  7. Risk stratification using lean body mass in patients undergoing transcatheter aortic valve replacement.

    Science.gov (United States)

    Hioki, Hirofumi; Watanabe, Yusuke; Kozuma, Ken; Yamamoto, Masanori; Naganuma, Toru; Araki, Motoharu; Tada, Norio; Shirai, Shinichi; Yamanaka, Futoshi; Higashimori, Akihiro; Mizutani, Kazuki; Tabata, Minoru; Takagi, Kensuke; Ueno, Hiroshi; Hayashida, Kentaro

    2018-02-22

    The prognostic impact of skeletal muscle mass, assessed using lean body mass (LBM), remain unclear in patients who underwent transcatheter aortic valve replacement (TAVR). The aim of this study to assess prognostic impact of LBM on mortality after TAVR. We assessed 1,613 patients (median age 85 years, 70% female) who underwent TAVI from October 2013 to April 2016 using OCEAN (Optimized transCathEter vAlvular interveNtion)-TAVI registry data. LBM was calculated using the James formula. The primary endpoint was all-cause death after TAVR. Median follow-up period was 287 days (interquartile range 110-462). The Kaplan-Meier analysis demonstrated that patients with low LBM had significantly higher incidence of all-cause death than those with high LBM in male (32.3% vs. 9.9%, log rank P LBM was an independent predictor of all-cause death in male (Hazard ratio [HR] 0.93; 95% confidence interval [CI] 0.89-0.98) and female (HR 0.94; 95% CI 0.89-0.99). Inversely, the assessment using BMI could not identify the high-risk population in a female. The patients with low LBM had the higher incidence of all-cause death after TAVR than those with high LBM, regardless of gender. Thus, the risk stratification using LBM might provide further insight to identify the high-risk TAVR population, compared to conventional risk stratification using BMI. © 2018 Wiley Periodicals, Inc.

  8. Mass separation and risk assessment of commingled contamination in soil and ground water

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Q.L.; Chau, T.S. [Alberta Environment, Red Deer, AB (Canada)

    2008-07-01

    Gasoline service stations in urban areas may be sources of groundwater pollution if petroleum hydrocarbons (PHCs) were to leak from underground storage tanks. Depending on the site-specific hydrogeologic conditions, the PHC could be retained in the soil, float on top of the groundwater table, dissolve in the groundwater or partition into soil vapour. This study focused on risk assessment and and management of soil and groundwater pollution caused by PHC releases from multiple sources which lead to commingling of subsurface plumes that require identification, assessment and control. Risk management decisions are made according to the different protection zones corresponding to different exposure pathways into which the commingled groundwater plume is divided, such as inhalation, ingestion and freshwater aquatic life. In order to effectively evaluate and manage commingled plumes, responsible parties must cooperate in sharing information on contaminated sites and developing joint programs for investigation, monitoring, remediation and risk management. This study proposed methodologies for determining mass contribution to a commingled plume from multiple contaminant sources. It was concluded that the levels of risk to human and environmental health can be determined by considering contaminant sources, migration pathways and potential receptors. Migration of PHCs in the subsurface is influenced by several uncertainties such as pollutant release and remediation histories, preferential pathways and hydrogeologic boundary conditions. Proper site characterization is necessary for reliable mass separation and to delineate contaminant plumes. Mathematical models can be used to simulate subsurface flow and transport processes. 5 refs., 4 figs.

  9. High risk of malnutrition is associated with low muscle mass in older hospitalized patients - a prospective cohort study.

    Science.gov (United States)

    Pierik, Vincent D; Meskers, Carel G M; Van Ancum, Jeanine M; Numans, Siger T; Verlaan, Sjors; Scheerman, Kira; Kruizinga, Roeliene C; Maier, Andrea B

    2017-06-05

    Malnutrition, low muscle strength and muscle mass are highly prevalent in older hospitalized patients and associated with adverse outcomes. Malnutrition may be a risk factor for developing low muscle mass. We aimed to investigate the association between the risk of malnutrition and 1) muscle strength and muscle mass at admission and 2) the change of muscle strength and muscle mass during hospitalization in older patients. The EMPOWER study included 378 patients aged seventy years or older who were acutely or electively admitted to four different wards of an academic teaching hospital in Amsterdam. Patients were grouped into low risk of malnutrition and high risk of malnutrition based on the Short Nutritional Assessment Questionnaire (SNAQ) score and were assessed for hand grip strength and muscle mass using hand held dynamometry respectively bioelectrical impedance analysis (BIA) within 48 h after admission and at day seven, or earlier at the day of discharge. Muscle mass was expressed as skeletal muscle mass, appendicular lean mass, fat free mass and the skeletal muscle index. The mean age of the patients was 79.7 years (SD 6.39), 48.9% were female. At admission, being at high risk of malnutrition was significantly associated with lower muscle mass (Odds Ratio, 95% CI, 0.90, 0.85-0.96), but not with muscle strength. Muscle strength and muscle mass did not change significantly during hospitalization in both groups. In older hospitalized patients, a high risk of malnutrition is associated with lower muscle mass at admission, but not with muscle strength nor with change of either muscle strength or muscle mass during hospitalization.

  10. Body mass index cut-points to identify cardiometabolic risk in black South Africans.

    Science.gov (United States)

    Kruger, H Salome; Schutte, Aletta E; Walsh, Corinna M; Kruger, Annamarie; Rennie, Kirsten L

    2017-02-01

    To determine optimal body mass index (BMI) cut-points for the identification of cardiometabolic risk in black South African adults. We performed a cross-sectional study of a weighted sample of healthy black South Africans aged 25-65 years (721 men, 1386 women) from the North West and Free State Provinces. Demographic, lifestyle and anthropometric measures were taken, and blood pressure, fasting serum triglycerides, high-density lipoprotein (HDL) cholesterol and blood glucose were measured. We defined elevated cardiometabolic risk as having three or more risk factors according to international metabolic syndrome criteria. Receiver operating characteristic curves were applied to identify an optimal BMI cut-point for men and women. BMI had good diagnostic performance to identify clustering of three or more risk factors, as well as individual risk factors: low HDL-cholesterol, elevated fasting glucose and triglycerides, with areas under the curve >.6, but not for high blood pressure. Optimal BMI cut-points averaged 22 kg/m 2 for men and 28 kg/m 2 for women, respectively, with better sensitivity in men (44.0-71.9 %), and in women (60.6-69.8 %), compared to a BMI of 30 kg/m 2 (17-19.1, 53-61.4 %, respectively). Men and women with a BMI >22 and >28 kg/m 2 , respectively, had significantly increased probability of elevated cardiometabolic risk after adjustment for age, alcohol use and smoking. In black South African men, a BMI cut-point of 22 kg/m 2 identifies those at cardiometabolic risk, whereas a BMI of 30 kg/m 2 underestimates risk. In women, a cut-point of 28 kg/m 2 , approaching the WHO obesity cut-point, identifies those at risk.

  11. Body mass index during adolescence, rather than childhood, is critical in determining MS risk.

    Science.gov (United States)

    Hedström, A K; Olsson, T; Alfredsson, L

    2016-06-01

    Obesity in childhood and during adolescence has repeatedly been associated with increased risk of developing multiple sclerosis (MS). We aimed to investigate whether the most critical period occurs during childhood or later, during adolescence. Using a population-based case-control study (1586 cases and 2800 controls), individuals with different body sizes at age 10 and different body mass indices at age 20 were compared regarding MS risk, by calculating odds ratios with 95% confidence intervals. Potential interactions between HLA-DRB1*15 and absence of HLA-A*02, respectively, and both childhood and adolescent obesity were evaluated by calculating the attributable proportion due to interaction. Regardless of body size at age 10, individuals with adolescent obesity had a 90% increased risk of MS. Among participants who were not obese at age 20, no association was observed between body size at age 10 and subsequent MS risk. An interaction was observed between the HLA MS risk genes and adolescent, but not childhood, obesity. Our results suggest that BMI during adolescence, rather than childhood, is critical in determining MS risk. © The Author(s), 2015.

  12. Benefit-risk analysis for mass screening of stomach cancer in Japan, 2

    International Nuclear Information System (INIS)

    Iinuma, Takeshi; Tateno, Yukio; Umegaki, Yoichiro; Hashizume, Tadashi; Kitabatake, Takashi.

    1978-01-01

    Mass screening of stomach cancer is one of the largest screening systems in Japan. In the previous paper, we have described the benefit-risk analysis in terms of life-saving due to early detection of stomach cancer and loss of life due to late induction of cancer by radiation. In this paper, we report the genetic effect of x-ray diagnosis used in the mass screening and cost-effectiveness for the screening program. The former is calculated by the product of genetically significant dose and rate of induction for genetic effects. Since the genetically significant dose in woman is about 10 times larger than that in man, the genetic risk is greater in woman accordingly. It is also found that the genetic risk over 40 years old is only 3% of the risk in the whole population and that it is almost neglected if the screening is performed only over age of 40. Cost of the screening is estimated to be yen 3,000/person which includes that of photofluorography and a part of other detailed examinations. Since total population screened is about 4 million in 1975, the total amount of cost is 1.2 x 10 10 yen/year. Cost per person-year is mainly dependent upon the age of the person: for one person-year in man or woman of 15 - 19 years old, the cost is about 20 million yen, but it is about 150,000 yen for man of 70 - 74 years old. These information is useful in the decision on the mass screening policy for stomach cancer in Japan. (auth.)

  13. Preliminary Interpretations of Multi-Channel Seismic Reflection and Magnetic Data on North Anatolian Fault (NAF) in the Eastern Marmara Region, Turkey

    Science.gov (United States)

    Gözde Okut Toksoy, Nigar; Kurt, Hülya; İşseven, Turgay

    2017-04-01

    The North Anatolian Fault (NAF) is 1600 km long, right lateral strike-slip fault nearly E-W elongated between Karlıova in the east and Saros Gulf in the west. NAF splays into two major strands near the west of Bolu city as Northern and Southern strands. Northern strand passes Sapanca Lake and extends towards west and reaches Marmara Sea through the Gulf of Izmit. The area has high seismicity; 1999 Kocaeli (Mw=7.4) and 1999 Düzce (Mw=7.2) earthquakes caused approximately 150 km long surface rupture between the Gulf of Izmit and Bolu. The rupture has four distinct fault segments as Gölcük, Sapanca, Sakarya, and Karadere from west to east. In this study multi-channel seismic and magnetic data are collected for the first time on the Sapanca Segment to investigate the surficial and deeper geometry of the NAF. Previously, the NAF in the eastern Marmara region is investigated using by paleo-seismological data from trenches on the surface rupture of fault or the geomorphological data (Lettis et al., 2000; Dikbaş and Akyüz, 2010) which have shallower depth targets. Crustal structure and seismic velocities for Central Anatolia and eastern Marmara regions are obtained from deeper targeted refraction data (Gürbüz et al., 1992). However, their velocity models do not have the spatial resolution to determine details of the fault zone structure. Multi-channel seismic and magnetic data in this study were acquired on two N-S directed profiles crossing NAF perpendicularly near Kartepe on the western part of the Sapanca Lake in October 2016. The receiver interval is 5 m, shot interval is 5-10 m, and the total length of the profiles are approximately 1400 m. Buffalo Gun is used as a seismic source for deeper penetration. Conventional seismic reflection processing steps are applied to the data. These are geometry definition, editing, filtering, static correction, velocity analysis and deconvolution, stacking and migration. Echos seismic software package in Geophysical Department

  14. Limb/trunk lean mass ratio as a risk factor for mortality in peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    Seok Hui Kang

    2012-06-01

    Full Text Available Protein energy wasting (PEW is a common problem in dialysis patients. There have been few reports on the effects of regional lean mass distribution for peritoneal dialysis (PD patients. We reviewed the medical records and identified all adults who received PD between May 2001 and May 2011. Five hundred thirty four patients were enrolled. The clinical and laboratory data were collected at 1 and 12 months. Regional lean masses were measured by dual-energy X-ray absorptiometry. The limb/trunk lean mass ratio (LTLM was defined as a value on dividing the sum of four limbs by the trunk lean mass. The mean age at the start of PD was 53.2±14.1 years. Diabetes mellitus (DM was most common underlying disease of end-stage renal disease (49.6%. In males, the low LTLM tertile was associated with low body mass index, creatinine, arm muscle circumference, and high C-reactive protein. In females, the low LTLM tertile was associated with low creatinine and normalized protein equivalent of nitrogen appearance. On both univariate and multivariate analysis adjusted for age, Davies risk index, and residual renal function, initial low LTLM tertile and maintenance of low LTLM were associated with mortality in PD patients. Distribution or change of regional lean mass may be more useful for predicting nutritional status. Initial low LTLM and maintenance of low LTLM were associated with mortality in PD patients. LTLM as a new marker would be useful for predicting the nutritional status and the mortality in patients on PD.

  15. Mass media and risk factors for cancer: the under-representation of age.

    Science.gov (United States)

    Macdonald, Sara; Cunningham, Yvonne; Patterson, Chris; Robb, Katie; Macleod, Una; Anker, Thomas; Hilton, Shona

    2018-04-26

    Increasing age is a risk factor for developing cancer. Yet, older people commonly underestimate this risk, are less likely to be aware of the early symptoms, and are more likely to be diagnosed with advanced stage cancer. Mass media are a key influence on the public's understanding health issues, including cancer risk. This study investigates how news media have represented age and other risk factors in the most common cancers over time. Eight hundred articles about the four most common cancers (breast, prostate, lung and colorectal) published within eight UK national newspapers in 2003, 2004, 2013 and 2014 were identified using the Nexis database. Relevant manifest content of articles was coded quantitatively and subjected to descriptive statistical analysis in SPSS to identify patterns across the data. Risk was presented in half of the articles but this was rarely discussed in any depth and around a quarter of all articles introduced more than one risk factor, irrespective of cancer site. Age was mentioned as a risk factor in approximately 12% of all articles and this varied by cancer site. Age was most frequently reported in relation to prostate cancer and least often in articles about lung cancer. Articles featuring personal narratives more frequently focused on younger people and this was more pronounced in non-celebrity stories; only 15% of non-celebrity narratives were about people over 60. Other common risks discussed were family history and genetics, smoking, diet, alcohol, and environmental factors. Family history and genetics together featured as the most common risk factors. Risk factor reporting varied by site and family history was most commonly associated with breast cancer, diet with bowel cancer and smoking with lung cancer. Age and older adults were largely obscured in media representation of cancer and cancer experience. Indeed common risk factors in general were rarely discussed in any depth. Our findings will usefully inform the development of

  16. Body mass index and risk for mental stress induced ischemia in coronary artery disease.

    Science.gov (United States)

    Soufer, Robert; Fernandez, Antonio B; Meadows, Judith; Collins, Dorothea; Burg, Matthew M

    2016-05-19

    Acute emotionally reactive mental stress (MS) can provoke prognostically relevant deficits in cardiac function and myocardial perfusion, and chronic inflammation increases risk for this ischemic phenomenon. We have described parasympathetic withdrawal and generation of inflammatory factors in MS. Adiposity is also associated with elevated markers of chronic inflammation. High body mass index (BMI) is frequently used as a surrogate for assessment of excess adiposity, and associated with traditional CAD risk factors, and CAD mortality. BMI is also associated with autonomic dysregulation, adipose tissue derived proinflammatory cytokines, which are also attendant to emotion provoked myocardial ischemia. Thus, we sought to determine if body mass index (BMI) contributes to risk of developing myocardial ischemia provoked by mental stress. We performed a prospective interventional study in a cohort of 161 patients with stable CAD. They completed an assessment of myocardial blood flow with single photon emission computed tomography (SPECT) simultaneously during 2 conditions: laboratory mental stress and at rest. Multivariate logistic regression determined the independent contribution of BMI to the occurrence of mental-stress induced ischemia. Mean age was 65.6±9.0 years; 87.0% had a history of hypertension, and 28.6% had diabetes. Mean BMI was 30.4±4.7. Prevalence of mental stress ischemia was 39.8%. BMI was an independent predictor of mental stress ischemia, OR=1.10, 95% CI [1.01-1.18] for one-point increase in BMI and OR=1.53, 95% CI [1.06-2.21] for a 4.7 point increase in BMI (one standard deviation beyond the cohort BMI mean), p=0.025 for all. These data suggest that BMI may serve as an independent risk marker for mental stress ischemia. The factors attendant with greater BMI, which include autonomic dysregulation and inflammation, may represent pathways by which high BMI contribute to this risk and serve as a conceptual construct to replicate these findings in larger

  17. Optimization method to determine mass transfer variables in a PWR crud deposition risk assessment tool

    International Nuclear Information System (INIS)

    Do, Chuong; Hussey, Dennis; Wells, Daniel M.; Epperson, Kenny

    2016-01-01

    Optimization numerical method was implemented to determine several mass transfer coefficients in a crud-induced power shift risk assessment code. The approach was to utilize a multilevel strategy that targets different model parameters that first changes the major order variables, mass transfer inputs, then calibrates the minor order variables, crud source terms, according to available plant data. In this manner, the mass transfer inputs are effectively simplified as 'dependent' on the crud source terms. Two optimization studies were performed using DAKOTA, a design and analysis toolkit, with the difference between the runs, being the number of model runs using BOA, allowed for adjusting the crud source terms, therefore, reducing the uncertainty with calibration. The result of the first case showed that the current best estimated values for the mass transfer coefficients, which were derived from first principle analysis, can be considered an optimized set. When the run limit of BOA was increased for the second case, an improvement in the prediction was obtained with the results deviating slightly from the best estimated values. (author)

  18. Biocides in the Yangtze River of China: Spatiotemporal distribution, mass load and risk assessment

    International Nuclear Information System (INIS)

    Liu, Wang-Rong; Zhao, Jian-Liang; Liu, You-Sheng; Chen, Zhi-Feng; Yang, Yuan-Yuan; Zhang, Qian-Qian; Ying, Guang-Guo

    2015-01-01

    Nineteen biocides were investigated in the Yangtze River to understand their spatiotemporal distribution, mass loads and ecological risks. Fourteen biocides were detected, with the highest concentrations up to 166 ng/L for DEET in surface water, and 54.3 ng/g dry weight (dw) for triclocarban in sediment. The dominant biocides were DEET and methylparaben, with their detection frequencies of 100% in both phases. An estimate of 152 t/y of 14 biocides was carried by the Yangtze River to the East China Sea. The distribution of biocides in the aquatic environments was significantly correlated to Gross Domestic Product (GDP), total phosphorus (TP) and total nitrogen (TN), suggesting dominant input sources from domestic wastewater of the cities along the river. Risk assessment showed high ecological risks posed by carbendazim in both phases and by triclosan in sediment. Therefore, proper measures should be taken to reduce the input of biocides into the river systems. - Highlights: • Biocides were ubiquitous in the surface water and sediment of the Yangtze River. • The dominant biocides in the Yangtze River were DEET and methylparaben. • Annual flux of biocides was 152 tons from the Yangtze River to the East China Sea. • Domestic wastewater was the main source of the biocides. • Carbendazim and triclosan posed high ecological risks. - Biocides showed wide presence in the Yangtze River and some of them could pose high ecological risks to aquatic organisms

  19. Body mass index and risk of BPH: a meta-analysis.

    Science.gov (United States)

    Wang, S; Mao, Q; Lin, Y; Wu, J; Wang, X; Zheng, X; Xie, L

    2012-09-01

    Epidemiological studies have reported conflicting results relating obesity to BPH. A meta-analysis of cohort and case-control studies was conducted to pool the risk estimates of the association between obesity and BPH. Eligible studies were retrieved by both computer searches and review of references. We analyzed abstracted data with random effects models to obtain the summary risk estimates. Dose-response meta-analysis was performed for studies reporting categorical risk estimates for a series of exposure levels. A total of 19 studies met the inclusion criteria of the meta-analysis. Positive association with body mass index (BMI) was observed in BPH and lower urinary tract symptoms (LUTS) combined group (odds ratio=1.27, 95% confidence intervals 1.05-1.53). In subgroup analysis, BMI exhibited a positive dose-response relationship with BPH/LUTS in population-based case-control studies and a marginal positive association was observed between risk of BPH and increased BMI. However, no association between BPH/LUTS and BMI was observed in other subgroups stratified by study design, geographical region or primary outcome. The overall current literatures suggested that BMI was associated with increased risk of BPH. Further efforts should be made to confirm these findings and clarify the underlying biological mechanisms.

  20. Obesity-risk behaviours and their associations with body mass index (BMI) in Korean American children.

    Science.gov (United States)

    Jang, Myoungock; Grey, Margaret; Sadler, Lois; Jeon, Sangchoon; Nam, Soohyun; Song, Hee-Jung; Whittemore, Robin

    2017-08-03

    To describe obesity-risk behaviours (diet, physical activity and sedentary behaviour) and examine the relationships of the obesity-risk behaviours with body mass index (BMI) in school-aged Korean American children. Korean American children have a risk of becoming overweight or obese and developing obesity-related complications; however, there is limited research about obesity-risk behaviours in Korean American children. A cross-sectional study. Obesity-risk behaviours of children were assessed with well-validated self-report questionnaires (i.e., Elementary-level School-based Nutrition Monitoring Questionnaire) from children and their mothers. Height and weight of children were measured. Data were analysed with bivariate and multivariate analyses using mixed effects models to incorporate the correlation within siblings. A total of 170 Korean American children (mean age 10.9 [2.0] years; 52.4% girls; mean BMI 19.3 [3.2]; 28.7% ≥85 percentiles) participated in the study. Only 38.3% of Korean American children met established recommendations of five fruits/vegetables per day; 56.5% met recommendations for more than 3 days per week of vigorous physical activity; and 40.8% met recommendations for obesity in Korean American children and initiate clinical interventions to improve obesity-risk behaviours, especially sedentary behaviour, in Korean American children. Clinical assessment and management of the risk of developing overweight and obesity as well as obesity-related behaviours are important to improve obesity-related complications in overall Korean Americans. © 2017 John Wiley & Sons Ltd.

  1. Body mass index, physical activity, and risk of adult meningioma and glioma: A meta-analysis.

    Science.gov (United States)

    Niedermaier, Tobias; Behrens, Gundula; Schmid, Daniela; Schlecht, Inga; Fischer, Beate; Leitzmann, Michael F

    2015-10-13

    Whether adiposity and lack of physical activity affect the risk for developing meningioma and glioma is poorly understood. Our objective was to characterize these associations in detail. We conducted a systematic review and meta-analysis of adiposity and physical activity in relation to meningioma and glioma using cohort and case-control studies published through February 2015. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We identified 12 eligible studies of body mass index (BMI) and 6 studies of physical activity, comprising up to 2,982 meningioma cases and 3,057 glioma cases. Using normal weight as the reference group, overweight (summary relative risk [RR] = 1.21, 95% confidence interval [CI] = 1.01-1.43) and obesity (RR = 1.54, 95% CI = 1.32-1.79) were associated with increased risk of meningioma. In contrast, overweight (RR = 1.06, 95% CI = 0.94-1.20) and obesity (RR = 1.11, 95% CI = 0.98-1.27) were unrelated to glioma. Similarly, dose-response meta-analyses revealed a statistically significant positive association of BMI with meningioma, but not glioma. High vs low physical activity levels showed a modest inverse relation to meningioma (RR = 0.73, 95% CI = 0.61-0.88) and a weak inverse association with glioma (RR = 0.86, 95% CI = 0.76-0.97). Relations persisted when the data were restricted to prospective studies, except for the association between physical activity and glioma, which was rendered statistically nonsignificant (RR = 0.91, 95% CI = 0.77-1.07). Adiposity is related to enhanced risk for meningioma but is unassociated with risk for glioma. Based on a limited body of evidence, physical activity is related to decreased risk of meningioma but shows little association with risk of glioma. © 2015 American Academy of Neurology.

  2. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-01-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO 2 ) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO 2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO 2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P 2 and tHb

  3. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  4. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.

    Science.gov (United States)

    Komorowski, Dariusz; Pietraszek, Stanislaw

    2016-01-01

    This paper presents the analysis of multi-channel electrogastrographic (EGG) signals using the continuous wavelet transform based on the fast Fourier transform (CWTFT). The EGG analysis was based on the determination of the several signal parameters such as dominant frequency (DF), dominant power (DP) and index of normogastria (NI). The use of continuous wavelet transform (CWT) allows for better visible localization of the frequency components in the analyzed signals, than commonly used short-time Fourier transform (STFT). Such an analysis is possible by means of a variable width window, which corresponds to the scale time of observation (analysis). Wavelet analysis allows using long time windows when we need more precise low-frequency information, and shorter when we need high frequency information. Since the classic CWT transform requires considerable computing power and time, especially while applying it to the analysis of long signals, the authors used the CWT analysis based on the fast Fourier transform (FFT). The CWT was obtained using properties of the circular convolution to improve the speed of calculation. This method allows to obtain results for relatively long records of EGG in a fairly short time, much faster than using the classical methods based on running spectrum analysis (RSA). In this study authors indicate the possibility of a parametric analysis of EGG signals using continuous wavelet transform which is the completely new solution. The results obtained with the described method are shown in the example of an analysis of four-channel EGG recordings, performed for a non-caloric meal.

  5. Imaging observations of nighttime mid-latitude F-region field-aligned irregularities by an MU radar ultra-multi-channel system

    Directory of Open Access Journals (Sweden)

    S. Saito

    2008-08-01

    Full Text Available Mid-latitude F-region field-aligned irregularities (FAIs were studied by using the middle-and-upper atmosphere (MU radar ultra-multi-channel system with the radar imaging technique. On 12 June 2006, F-region FAI echoes with a period of about one hour were observed intermittently. These echoes were found to be embedded in medium-scale traveling ionospheric disturbances (MSTIDs observed as variations of total electron content (TEC. The echoes drifting away from (toward the radar were observed in the depletion (enhancement phase of the MSTID. The Doppler velocity of the echoes is consistent with the range rates in the the range-time-intensity (RTI maps. Fine scale structures with a spatial scale of 10 km or less were found by the radar imaging analysis. Those structures with positive Doppler velocities (moving away from the radar appeared to drift north- (up- westward, and those with negative Doppler velocities south- (down- eastward approximately along the wavefronts of the MSTID. FAIs with positive Doppler velocities filling TEC depletion regions were observed.

  6. The EarthScope Array Network Facility: application-driven low-latency web-based tools for accessing high-resolution multi-channel waveform data

    Science.gov (United States)

    Newman, R. L.; Lindquist, K. G.; Clemesha, A.; Vernon, F. L.

    2008-12-01

    Since April 2004 the EarthScope USArray seismic network has grown to over 400 broadband stations that stream multi-channel data in near real-time to the Array Network Facility in San Diego. Providing secure, yet open, access to real-time and archived data for a broad range of audiences is best served by a series of platform agnostic low-latency web-based applications. We present a framework of tools that interface between the world wide web and Boulder Real Time Technologies Antelope Environmental Monitoring System data acquisition and archival software. These tools provide audiences ranging from network operators and geoscience researchers, to funding agencies and the general public, with comprehensive information about the experiment. This ranges from network-wide to station-specific metadata, state-of-health metrics, event detection rates, archival data and dynamic report generation over a stations two year life span. Leveraging open source web-site development frameworks for both the server side (Perl, Python and PHP) and client-side (Flickr, Google Maps/Earth and jQuery) facilitates the development of a robust extensible architecture that can be tailored on a per-user basis, with rapid prototyping and development that adheres to web-standards.

  7. Segmentation and profiling consumers in a multi-channel environment using a combination of self-organizing maps (SOM method, and logistic regression

    Directory of Open Access Journals (Sweden)

    Seyed Ali Akbar Afjeh

    2014-05-01

    Full Text Available Market segmentation plays essential role on understanding the behavior of people’s interests in purchasing various products and services through various channels. This paper presents an empirical investigation to shed light on consumer’s purchasing attitude as well as gathering information in multi-channel environment. The proposed study of this paper designed a questionnaire and distributed it among 800 people who were at least 18 years of age and had some experiences on purchasing goods and services on internet, catalog or regular shopping centers. Self-organizing map, SOM, clustering technique was performed based on consumer’s interest in gathering information as well as purchasing products through internet, catalog and shopping centers and determined four segments. There were two types of questions for the proposed study of this paper. The first group considered participants’ personal characteristics such as age, gender, income, etc. The second group of questions was associated with participants’ psychographic characteristics including price consciousness, quality consciousness, time pressure, etc. Using multinominal logistic regression technique, the study determines consumers’ behaviors in each four segments.

  8. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Durand, Marie-Jose; Jouanneau, Sulivan; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Dion, Michel [UMR CNRS 6204, Nantes University, PRES UNAM, Biotechnologie, Biocatalyse, Bioregulation, 2, Rue de la Houssiniere, BP 92208, Nantes cedex 3 (France); Pernetti, Mimma; Poncelet, Denis [ONIRIS-ENITIAA, UMR CNRS GEPEA, Rue de la Geraudiere, BP 82225, Nantes cedex 3 (France)

    2011-05-15

    This study describes the construction of inducible bioluminescent strains via genetic engineering along with their characterization and optimization in the detection of heavy metals. Firstly, a preliminary comparative study enabled us to select a suitable carbon substrate from pyruvate, glucose, citrate, diluted Luria-Bertani, and acetate. The latter carbon source provided the best induction ratios for comparison. Results showed that the three constructed inducible strains, Escherichia coli DH1 pBzntlux, pBarslux, and pBcoplux, were usable when conducting a bioassay after a 14-h overnight culture at 30 C. Utilizing these sensors gave a range of 12 detected heavy metals including several cross-detections. Detection limits for each metal were often close to and sometimes lower than the European standards for water pollution. Finally, in order to maintain sensitive bacteria within the future biosensor-measuring cell, the agarose immobilization matrix was compared to polyvinyl alcohol (PVA). Agarose was selected because the detection limits of the bioluminescent strains were not affected, in contrast to PVA. Specific detection and cross-detection ranges determined in this study will form the basis of a multiple metals detection system by the new multi-channel Lumisens3 biosensor. (orig.)

  9. Biodegradation of a commercial mixture of the herbicides atrazine and S-metolachlor in a multi-channel packed biofilm reactor.

    Science.gov (United States)

    Cabrera-Orozco, Alberto; Galíndez-Nájera, Silvia Patricia; Ruiz-Ordaz, Nora; Galíndez-Mayer, Juvencio; Martínez-Jerónimo, Fernando

    2017-11-01

    Atrazine and S-metolachlor are two of the most widely used herbicides for agricultural purposes; consequently, residues of both compounds and their metabolites had been detected in ground and superficial waters. Unlike atrazine, the complete degradation of metolachlor has not been achieved. Hence, the purpose of this research is to study the biodegradation of a commercial mixture of atrazine and S-metolachlor in a prototype of a multi-channel packed-bed-biofilm reactor (MC-PBR) designed with the aim of solving the problems of pressure drop and oxygen transfer, typically found on this type of bioreactors.Because the removal efficiency of the herbicides was increased when Candida tropicalis was added to the original microbial community isolated, the reactor was inoculated with this enriched community. The operational conditions tested in batch and continuous mode did not affect the removal efficiency of atrazine; however, this was not the case for S-metolachlor. The removal rates and efficiencies showed a notable variation along the MC-PBR operation.

  10. 12.5 Gb/s multi-channel broadcasting transmission for free-space optical communication based on the optical frequency comb module.

    Science.gov (United States)

    Tan, Jun; Zhao, Zeping; Wang, Yuehui; Zhang, Zhike; Liu, Jianguo; Zhu, Ninghua

    2018-01-22

    A wide-spectrum, ultra-stable optical frequency comb (OFC) module with 100 GHz frequency intervals based on a quantum dot mode locked (QDML) laser is fabricated by our lab, and a scheme with 12.5 Gb/s multi-channel broadcasting transmission for free-space optical (FSO) communication is proposed based on the OFC module. The output power of the OFC is very stable, with the specially designed circuit and the flatness of the frequency comb over the span of 6 nm, which can be limited to 1.5 dB. Four channel wavelengths are chosen to demonstrate one-to-many channels for FSO communication, like optical wireless broadcast. The outdoor experiment is established to test the bit error rate (BER) and eye diagrams with 12.5 Gb/s on-off keying (OOK). The indoor experiment is used to test the highest traffic rate, which is up to 21 Gb/s for one-hop FSO communication. To the best of our knowledge, this scheme is the first to propose the realization of one-to-many broadcasting transmission for FSO communication based on the OFC module. The advantages of integration, miniaturization, channelization, low power consumption, and unlimited bandwidth of one-to-many broadcasting communication scheme, shows promising results on constructing the future space-air-ground-ocean (SAGO) FSO communication networks.

  11. The design of the layout of faceted multi-channel electro-optical spatial coordinates measuring instrument for point-like bright objects

    Science.gov (United States)

    Repin, Vladislav A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2017-06-01

    For many applied problems it is necessary to obtain information about the situation in a wide angular field in order to measure various parameters of objects: their spatial coordinates, instantaneous velocities, and so on. In this case, one interesting bionic approach can be used - a mosaic (or discrete, otherwise, facet) angular field. Such electro-optical system constructively imitates the visual apparatus of insects: many photodetectors like ommatidia (elements of the facet eye structure) are located on a non-planar surface. Such devices can be used in photogrammetry and aerial photography systems (if the space is sufficient), in the transport sector as vehicle orientation organs, as systems for monitoring in unmanned aerial vehicles, in endoscopy for obtaining comprehensive information on the state of various cavities, in intelligent robotic systems. In this manuscript discusses the advantages and disadvantages of multi-channeled optoelectronic systems with a mosaic angular field, presents possible options for their use, and discusses some of the design procedures performed when developing a layout of a coordinate measuring device.

  12. Is risk of degenerative musculoskeletal conditions associated with pre-pregnancy body mass index and parity?

    DEFF Research Database (Denmark)

    Bliddal, Mette; Pottegård, Anton; Kirkegaard, Helene

    Background Obesity among women may influence the risk of degenerative musculoskeletal conditions (MSCs) and contribute to poor quality of life. Parity, which constitutes a sudden natural increase in weight as well it affects long-term body mass index (BMI), may put strain on the musculoskeletal....... Information on height and weight prior to pregnancy was obtained from telephone interviews and parity from the Danish Medical Birth Registry. Diagnoses on degenerative MSC including osteoarthritis, disc disorders, low back pain, and soft tissue disorders were obtained from the National Patient Registry......% confidence interval 1.41-1.83]). Conclusions High pre-pregnancy BMI increased the occurrence of degenerative MSC in the years following pregnancy and childbirth. In combination with increasing pre-pregnancy BMI, higher parity added to an already elevated risk. Prevention of maternal overweight may reduce...

  13. Childhood body mass index in relation to future risk of oesophageal adenocarcinoma

    DEFF Research Database (Denmark)

    Cook, M B; Freedman, N D; Gamborg, M

    2015-01-01

    BACKGROUND: Middle-aged obese adults are at substantially elevated risk of oesophageal adenocarcinoma. It is unclear whether this risk originates earlier in life. METHODS: We assessed associations between childhood body mass index (BMI) and height-measured annually between ages 7 and 13-with adult....... RESULTS: During 5.4 million person-years of follow-up, 254 (216 males) incident oesophageal adenocarcinomas occurred. At each examined age, cancer risk increased linearly per unit BMI z-score, although associations were only statistically significant for ages 9-13. The HR for the age of 13 years was 1.......31 (95% CI: 1.13, 1.51) per unit BMI z-score. Associations were similar in men and women and across birth cohorts. Childhood height was not related to cancer risk in men but was in women, although these analyses included just 38 female cases. HRs per unit height z-score at the age of 13 years were 1...

  14. Percent body fat is a better predictor of cardiovascular risk factors than body mass index

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Qiang; Dong, Sheng-Yong; Sun, Xiao-Nan; Xie, Jing; Cui, Yi [International Medical Center, Chinese PLA General Hospital, Beijing (China)

    2012-04-20

    The objective of the present study was to evaluate the predictive values of percent body fat (PBF) and body mass index (BMI) for cardiovascular risk factors, especially when PBF and BMI are conflicting. BMI was calculated by the standard formula and PBF was determined by bioelectrical impedance analysis. A total of 3859 ambulatory adult Han Chinese subjects (2173 males and 1686 females, age range: 18-85 years) without a history of cardiovascular diseases were recruited from February to September 2009. Based on BMI and PBF, they were classified into group 1 (normal BMI and PBF, N = 1961), group 2 (normal BMI, but abnormal PBF, N = 381), group 3 (abnormal BMI, but normal PBF, N = 681), and group 4 (abnormal BMI and PBF, N = 836). When age, gender, lifestyle, and family history of obesity were adjusted, PBF, but not BMI, was correlated with blood glucose and lipid levels. The odds ratio (OR) and 95% confidence interval (CI) for cardiovascular risk factors in groups 2 and 4 were 1.88 (1.45-2.45) and 2.06 (1.26-3.35) times those in group 1, respectively, but remained unchanged in group 3 (OR = 1.32, 95%CI = 0.92-1.89). Logistic regression models also demonstrated that PBF, rather than BMI, was independently associated with cardiovascular risk factors. In conclusion, PBF, and not BMI, is independently associated with cardiovascular risk factors, indicating that PBF is a better predictor.

  15. Percent body fat is a better predictor of cardiovascular risk factors than body mass index

    International Nuclear Information System (INIS)

    Zeng, Qiang; Dong, Sheng-Yong; Sun, Xiao-Nan; Xie, Jing; Cui, Yi

    2012-01-01

    The objective of the present study was to evaluate the predictive values of percent body fat (PBF) and body mass index (BMI) for cardiovascular risk factors, especially when PBF and BMI are conflicting. BMI was calculated by the standard formula and PBF was determined by bioelectrical impedance analysis. A total of 3859 ambulatory adult Han Chinese subjects (2173 males and 1686 females, age range: 18-85 years) without a history of cardiovascular diseases were recruited from February to September 2009. Based on BMI and PBF, they were classified into group 1 (normal BMI and PBF, N = 1961), group 2 (normal BMI, but abnormal PBF, N = 381), group 3 (abnormal BMI, but normal PBF, N = 681), and group 4 (abnormal BMI and PBF, N = 836). When age, gender, lifestyle, and family history of obesity were adjusted, PBF, but not BMI, was correlated with blood glucose and lipid levels. The odds ratio (OR) and 95% confidence interval (CI) for cardiovascular risk factors in groups 2 and 4 were 1.88 (1.45-2.45) and 2.06 (1.26-3.35) times those in group 1, respectively, but remained unchanged in group 3 (OR = 1.32, 95%CI = 0.92-1.89). Logistic regression models also demonstrated that PBF, rather than BMI, was independently associated with cardiovascular risk factors. In conclusion, PBF, and not BMI, is independently associated with cardiovascular risk factors, indicating that PBF is a better predictor

  16. Individual and shared effects of social environment and polygenic risk scores on adolescent body mass index.

    Science.gov (United States)

    Coleman, Jonathan R I; Krapohl, Eva; Eley, Thalia C; Breen, Gerome

    2018-04-20

    Juvenile obesity is associated with adverse health outcomes. Understanding genetic and environmental influences on body mass index (BMI) during adolescence could inform interventions. We investigated independent and interactive effects of parenting, socioeconomic status (SES) and polygenic risk on BMI pre-adolescence, and on the rate of change in BMI across adolescence. Genome-wide genotype data, BMI and child perceptions of parental warmth and punitive discipline were available at 11 years old, and parental SES was available from birth on 3,414 unrelated participants. Linear models were used to test the effects of social environment and polygenic risk on pre-adolescent BMI. Change in BMI across adolescence was assessed in a subset (N = 1943). Sex-specific effects were assessed. Higher genetic risk was associated with increased BMI pre-adolescence and across adolescence (p parenting was not significantly associated with either phenotype, but lower SES was associated with increased BMI pre-adolescence. No interactions passed correction for multiple testing. Polygenic risk scores from adult GWAS meta-analyses are associated with BMI in juveniles, suggesting a stable genetic component. Pre-adolescent BMI was associated with social environment, but parental style has, at most, a small effect.

  17. The Relationship between Native American Ancestry, Body Mass Index and Diabetes Risk among Mexican-Americans.

    Science.gov (United States)

    Hu, Hao; Huff, Chad D; Yamamura, Yuko; Wu, Xifeng; Strom, Sara S

    2015-01-01

    Higher body mass index (BMI) is a well-established risk factor for type 2 diabetes, and rates of obesity and type 2 diabetes are substantially higher among Mexican-Americans relative to non-Hispanic European Americans. Mexican-Americans are genetically diverse, with a highly variable distribution of Native American, European, and African ancestries. Here, we evaluate the role of Native American ancestry on BMI and diabetes risk in a well-defined Mexican-American population. Participants were randomly selected among individuals residing in the Houston area who are enrolled in the Mexican-American Cohort study. Using a custom Illumina GoldenGate Panel, we genotyped DNA from 4,662 cohort participants for 87 Ancestry-Informative Markers. On average, the participants were of 50.2% Native American ancestry, 42.7% European ancestry and 7.1% African ancestry. Using multivariate linear regression, we found BMI and Native American ancestry were inversely correlated; individuals with ancestry were 2.5 times more likely to be severely obese compared to those with >80% Native American ancestry. Furthermore, we demonstrated an interaction between BMI and Native American ancestry in diabetes risk among women; Native American ancestry was a strong risk factor for diabetes only among overweight and obese women (OR = 1.190 for each 10% increase in Native American ancestry). This study offers new insight into the complex relationship between obesity, genetic ancestry, and their respective effects on diabetes risk. Findings from this study may improve the diabetes risk prediction among Mexican-American individuals thereby facilitating targeted prevention strategies.

  18. Common variants near MC4R are associated with fat mass, weight and risk of obesity

    Science.gov (United States)

    Loos, Ruth J F; Lindgren, Cecilia M; Li, Shengxu; Wheeler, Eleanor; Zhao, Jing Hua; Prokopenko, Inga; Inouye, Michael; Freathy, Rachel M; Attwood, Antony P; Beckmann, Jacques S; Berndt, Sonja I; Bergmann, Sven; Bennett, Amanda J; Bingham, Sheila A; Bochud, Murielle; Brown, Morris; Cauchi, Stéphane; Connell, John M; Cooper, Cyrus; Smith, George Davey; Day, Ian; Dina, Christian; De, Subhajyoti; Dermitzakis, Emmanouil T; Doney, Alex S F; Elliott, Katherine S; Elliott, Paul; Evans, David M; Farooqi, I Sadaf; Froguel, Philippe; Ghori, Jilur; Groves, Christopher J; Gwilliam, Rhian; Hadley, David; Hall, Alistair S; Hattersley, Andrew T; Hebebrand, Johannes; Heid, Iris M; Herrera, Blanca; Hinney, Anke; Hunt, Sarah E; Jarvelin, Marjo-Riitta; Johnson, Toby; Jolley, Jennifer D M; Karpe, Fredrik; Keniry, Andrew; Khaw, Kay-Tee; Luben, Robert N; Mangino, Massimo; Marchini, Jonathan; McArdle, Wendy L; McGinnis, Ralph; Meyre, David; Munroe, Patricia B; Morris, Andrew D; Ness, Andrew R; Neville, Matthew J; Nica, Alexandra C; Ong, Ken K; O'Rahilly, Stephen; Owen, Katharine R; Palmer, Colin N A; Papadakis, Konstantinos; Potter, Simon; Pouta, Anneli; Qi, Lu; Randall, Joshua C; Rayner, Nigel W; Ring, Susan M; Sandhu, Manjinder S; Scherag, André; Sims, Matthew A; Song, Kijoung; Soranzo, Nicole; Speliotes, Elizabeth K; Syddall, Holly E; Teichmann, Sarah A; Timpson, Nicholas J; Tobias, Jonathan H; Uda, Manuela; Vogel, Carla I Ganz; Wallace, Chris; Waterworth, Dawn M; Weedon, Michael N; Willer, Cristen J; Wraight, Vicki L; Yuan, Xin; Zeggini, Eleftheria; Hirschhorn, Joel N; Strachan, David P; Ouwehand, Willem H; Caulfield, Mark J; Samani, Nilesh J; Frayling, Timothy M; Vollenweider, Peter; Waeber, Gerard; Mooser, Vincent; Deloukas, Panos; McCarthy, Mark I; Wareham, Nicholas J; Barroso, Inês; Jacobs, Kevin B; Chanock, Stephen J; Hayes, Richard B; Lamina, Claudia; Gieger, Christian; Illig, Thomas; Meitinger, Thomas; Wichmann, H-Erich; Kraft, Peter; Hankinson, Susan E; Hunter, David J; Hu, Frank B; Lyon, Helen N; Voight, Benjamin F; Ridderstrale, Martin; Groop, Leif; Scheet, Paul; Sanna, Serena; Abecasis, Goncalo R; Albai, Giuseppe; Nagaraja, Ramaiah; Schlessinger, David; Jackson, Anne U; Tuomilehto, Jaakko; Collins, Francis S; Boehnke, Michael; Mohlke, Karen L

    2009-01-01

    To identify common variants influencing body mass index (BMI), we analyzed genome-wide association data from 16,876 individuals of European descent. After previously reported variants in FTO, the strongest association signal (rs17782313, P = 2.9 × 10−6) mapped 188 kb downstream of MC4R (melanocortin-4 receptor), mutations of which are the leading cause of monogenic severe childhood-onset obesity. We confirmed the BMI association in 60,352 adults (per-allele effect = 0.05 Z-score units; P = 2.8 × 10−15) and 5,988 children aged 7–11 (0.13 Z-score units; P = 1.5 × 10−8). In case-control analyses (n = 10,583), the odds for severe childhood obesity reached 1.30 (P = 8.0 × 10−11). Furthermore, we observed overtransmission of the risk allele to obese offspring in 660 families (P (pedigree disequilibrium test average; PDT-avg) = 2.4 × 10−4). The SNP location and patterns of phenotypic associations are consistent with effects mediated through altered MC4R function. Our findings establish that common variants near MC4R influence fat mass, weight and obesity risk at the population level and reinforce the need for large-scale data integration to identify variants influencing continuous biomedical traits. PMID:18454148

  19. Risk of malignancy index in the preoperative evaluation of patients with ovarian masses

    International Nuclear Information System (INIS)

    Jabeen, R.; Khan, S.A.; Naveed, S.

    2015-01-01

    Objective: To evaluate the ability of RMI in preoperative discrimination of benign from malignant ovarian mass among women presenting at Nishtar Hospital Multan Pakistan. Methodology: It was a prospective study conducted at department of obstetrics/gynae Nishtar Hospital Multan between September 2008 to August 2009. 60 patients of more than 30 years of age admitted in gynaecology department for surgical exploration of ovarian mass were included. All the women in whom ovarian malignancy had already been diagnosed and admitted for second laparotomy were excluded. Results: The median age at presentation of ovarian malignancy is 56 years. The sensitivity of RMI in our group was 82.3%,the specificity was 88.3%, positive predictive value was 73.7% and the negative predictive value was 92.6%. Receiver operating curves reveal that RMI was a better diagnostic marker than CA-125 or ultrasound score alone for the prediction of malignancy in ovarian masses. Conclusion: The risk of malignancy index has high specificity and sensitivity. It yielded a better diagnostic performance as compared to CA-125 or ultrasound score alone in differentiating benign from malignant ovarian lesions. (author)

  20. Visceral fat mass: is it the link between uric acid and diabetes risk?

    Science.gov (United States)

    Seyed-Sadjadi, Neda; Berg, Jade; Bilgin, Ayse A; Grant, Ross

    2017-07-24

    Uric acid (UA) has been suggested as a novel risk factor for diabetes. However, its definite role in this prevalent disease is still the subject of much discussion because it is always accompanied with other major risk factors such as obesity and high visceral adiposity. In order to clarify the role of UA in diabetes, this study aimed to investigate the associations between plasma UA and fasting plasma glucose, HbA1c, lipid profile and inflammatory markers after accounting for the contribution of other diabetes risk factors such as BMI and VAT fat mass. In the present cross-sectional study, 100 non-diabetic middle-aged males (n = 48) and females (n = 52) were recruited. Central fat distribution measures including android to gynoid fat ratio, VAT and subcutaneous adipose tissue (SAT) fat mass were determined using dual-energy X-ray absorptiometry (DXA). Biochemical analysis was done using methods well established for clinical and research laboratories. Multiple linear regression analysis was performed to analyse the association between plasma UA and the biochemical and central fat distribution measures. UA was positivly associated with body mass index (BMI) (r (98) = 0.42, P ≤ 0.001), android to gynoid fat ratio (r (98) = 0.62, P ≤ 0.001) and VAT fat mass (r (96) = 0.55, P ≤ 0.001). UA was also positively associated with plasma glucose (r (98) = 0.33, P ≤ 0.001), hemoglobin A1c (r (93) = 0.25, P = 0.014), plasma triglyceride (r s (95) = 0.40, P ≤ 0.001), HDL cholesterol (r (98) = - 0.61, P ≤ 0.001) and CRP (r s (98) = 0.23, P = 0.026). However, these associations were no longer significant after accounting for BMI or/and VAT fat mass. No significant association was observed between UA and SAT fat mass (r (97) = 0.02, P ≥ 0.05), Total cholesterol (r (98) = 0.03, P ≥ 0.05), LDL cholesterol (r (98) = 0.13, P ≥ 0.05), TNF-α (r (97) = 0.12, P ≥ 0.05) and IL-6 (r (96) = -0.02, P ≥ 0

  1. Elevated body mass index and risk of postoperative CSF leak following transsphenoidal surgery

    Science.gov (United States)

    Dlouhy, Brian J.; Madhavan, Karthik; Clinger, John D.; Reddy, Ambur; Dawson, Jeffrey D.; O’Brien, Erin K.; Chang, Eugene; Graham, Scott M.; Greenlee, Jeremy D. W.

    2012-01-01

    Object Postoperative CSF leakage can be a serious complication after a transsphenoidal surgical approach. An elevated body mass index (BMI) is a significant risk factor for spontaneous CSF leaks. However, there is no evidence correlating BMI with postoperative CSF leak after transsphenoidal surgery. The authors hypothesized that patients with elevated BMI would have a higher incidence of CSF leakage complications following transsphenoidal surgery. Methods The authors conducted a retrospective review of 121 patients who, between August 2005 and March 2010, underwent endoscopic endonasal transsphenoidal surgeries for resection of primarily sellar masses. Patients requiring extended transsphenoidal approaches were excluded. A multivariate statistical analysis was performed to investigate the association of BMI and other risk factors with postoperative CSF leakage. Results In 92 patients, 96 endonasal endoscopic transsphenoidal surgeries were performed that met inclusion criteria. Thirteen postoperative leaks occurred and required subsequent treatment, including lumbar drainage and/or reoperation. The average BMI of patients with a postoperative CSF leak was significantly greater than that in patients with no postoperative CSF leak (39.2 vs 32.9 kg/m2, p = 0.006). Multivariate analyses indicate that for every 5-kg/m2 increase in BMI, patients undergoing a transsphenoidal approach for a primarily sellar mass have 1.61 times the odds (95% CI 1.10–2.29, p = 0.016, by multivariate logistic regression) of having a postoperative CSF leak. Conclusions Elevated BMI is an independent predictor of postoperative CSF leak after an endonasal endoscopic transsphenoidal approach. The authors recommend that patients with BMI greater than 30 kg/m2 have meticulous sellar reconstruction at surgery and close monitoring postoperatively. PMID:22443502

  2. Risk of Fracture in Women with Sarcopenia, Low Bone Mass, or Both.

    Science.gov (United States)

    Harris, Rebekah; Chang, Yuefang; Beavers, Kristen; Laddu-Patel, Deepika; Bea, Jennifer; Johnson, Karen; LeBoff, Meryl; Womack, Catherine; Wallace, Robert; Li, Wenjun; Crandall, Carolyn; Cauley, Jane

    2017-12-01

    To determine whether women with sarcopenia and low bone mineral density (BMD) are at greater risk of clinical fractures than those with sarcopenia or low BMD alone. Women's Health Initiative (WHI) Observational and Clinical trials. Three U.S. clinical centers (Pittsburgh, PA; Birmingham, AL; Phoenix/Tucson, AZ). Women (mean age 63.3 ± 0.07) with BMD measurements (N = 10,937). Sarcopenia was defined as appendicular lean mass values corrected for height and fat mass. Low BMD was defined as a femoral neck T-score less than -1.0 based on the Third National Health and Nutrition Examination Survey reference database for white women. Cox proportional hazards analysis was used to calculate hazard ratios (HRs) and 95% confidence intervals (CIs). We followed women for incident fractures over a median of 15.9 years. Participants were classified into mutually exclusive groups based on BMD and sarcopenia status: normal BMD and no sarcopenia (n = 3,857, 35%), sarcopenia alone (n = 774, 7%), low BMD alone (n = 4,907, 45%), and low BMD and sarcopenia (n = 1,399, 13%). Women with low BMD, with (HR = 1.72, 95% CI = 1.44-2.06) or without sarcopenia (HR = 1.58, 95% CI = 1.37-1.83), had greater risk of fracture than women with normal BMD; the difference remained statistically significant after adjustment for important covariates. Women with low BMD, with (HR = 2.78, 95% CI = 1.78-4.30 and without (HR = 2.42, 95% CI = 1.63-3.59) sarcopenia had higher risk of hip fractures. Women with sarcopenia alone had similar HRs to women with normal BMD. Compared to women with normal BMD. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  3. Risk communication considerations to facilitate the screening of mass populations for potential contamination with radioactive material.

    Science.gov (United States)

    Emery, R J; Sprau, D D; Morecook, R C

    2008-11-01

    Experience gained during a field training exercise with a Medical Reserve Corps unit on the screening of large groups of individuals for possible contamination with radioactive material revealed that while exercise participants were generally attentive to the proper use of protective equipment and detectors, they tended to overlook important basic risk communications aspects. For example, drill participants did not actively communicate with the persons waiting in line for screening, a step which would provide re-assurance, possibly minimize apprehension, and would clarify expectations. When questioned on this issue of risk communication, drill participants were often able to craft ad hoc messages, but the messages were inconsistent and likely would not have significantly helped diminish anxiety and maintain crowd control. Similar difficulties were encountered regarding messaging for persons determined to be contaminated, those departing the screening center, and those to be delivered to the media. Based on these experiences, the need for a suggested list of risk communication points was identified. To address this need, a set of risk communication templates were developed that focused on the issues likely to be encountered in a mass screening event. The points include issues such as the importance of remaining calm, steps for minimizing possible intake or uptake, considerations for those exhibiting acute injuries, expected screening wait times, the process to be followed and the information to be collected, the process to be undertaken for those exhibiting contamination, and symptoms to watch for after departure. Drill participants indicated in follow-up discussions that such pre-established risk communication templates would serve to enhance their ability to assist in times of emergency and noted the potential broader applicably of the approach for use in responses for other disasters types as well.

  4. Body mass index in relation to serum prostate-specific antigen levels and prostate cancer risk.

    Science.gov (United States)

    Bonn, Stephanie E; Sjölander, Arvid; Tillander, Annika; Wiklund, Fredrik; Grönberg, Henrik; Bälter, Katarina

    2016-07-01

    High Body mass index (BMI) has been directly associated with risk of aggressive or fatal prostate cancer. One possible explanation may be an effect of BMI on serum levels of prostate-specific antigen (PSA). To study the association between BMI and serum PSA as well as prostate cancer risk, a large cohort of men without prostate cancer at baseline was followed prospectively for prostate cancer diagnoses until 2015. Serum PSA and BMI were assessed among 15,827 men at baseline in 2010-2012. During follow-up, 735 men were diagnosed with prostate cancer with 282 (38.4%) classified as high-grade cancers. Multivariable linear regression models and natural cubic linear regression splines were fitted for analyses of BMI and log-PSA. For risk analysis, Cox proportional hazards regression models were used to estimate hazard ratios (HR) and 95% confidence intervals (CI) and natural cubic Cox regression splines producing standardized cancer-free probabilities were fitted. Results showed that baseline Serum PSA decreased by 1.6% (95% CI: -2.1 to -1.1) with every one unit increase in BMI. Statistically significant decreases of 3.7, 11.7 and 32.3% were seen for increasing BMI-categories of 25 prostate cancer risk although results were indicative of a positive association to incidence rates of high-grade disease and an inverse association to incidence of low-grade disease. However, findings regarding risk are limited by the short follow-up time. In conclusion, BMI was inversely associated to PSA-levels. BMI should be taken into consideration when referring men to a prostate biopsy based on serum PSA-levels. © 2016 UICC.

  5. SCOTCH: a program for solution of the one-dimensional, two-group, space-time neutron diffusion equations with temperature feedback of multi-channel fluid dynamics for HTGR cores

    International Nuclear Information System (INIS)

    Ezaki, Masahiro; Mitake, Susumu; Ozawa, Tamotsu

    1979-06-01

    The SCOTCH program solves the one-dimensional (R or Z), two-group reactor kinetics equations with multi-channel temperature transients and fluid dynamics. Sub-program SCOTCH-RX simulates the space-time neutron diffusion in radial direction, and sub-program SCOTCH-AX simulates the same in axial direction. The program has about 8,000 steps of FORTRAN statement and requires about 102 kilo-words of computer memory. (author)

  6. Getting ready for the marriage market? The association between divorce risks and investments in attractive body mass among married Europeans

    NARCIS (Netherlands)

    Lundborg, N.; Lindgren, B.; Nystedt, P.

    2007-01-01

    This article explores to what extent married middle-aged individuals in Europe are governed by the risk of experiencing divorce, when shaping their physical appearance. The main result is that divorce risks, proxied by national divorce rates, are negatively connected to body mass index (BMI) among

  7. Body mass index and risk of colorectal carcinoma subtypes classified by tumor differentiation status.

    Science.gov (United States)

    Hanyuda, Akiko; Cao, Yin; Hamada, Tsuyoshi; Nowak, Jonathan A; Qian, Zhi Rong; Masugi, Yohei; da Silva, Annacarolina; Liu, Li; Kosumi, Keisuke; Soong, Thing Rinda; Jhun, Iny; Wu, Kana; Zhang, Xuehong; Song, Mingyang; Meyerhardt, Jeffrey A; Chan, Andrew T; Fuchs, Charles S; Giovannucci, Edward L; Ogino, Shuji; Nishihara, Reiko

    2017-05-01

    Previous studies suggest that abnormal energy balance status may dysregulate intestinal epithelial homeostasis and promote colorectal carcinogenesis, yet little is known about how host energy balance and obesity influence enterocyte differentiation during carcinogenesis. We hypothesized that the association between high body mass index (BMI) and colorectal carcinoma incidence might differ according to tumor histopathologic differentiation status. Using databases of the Nurses' Health Study and Health Professionals Follow-up Study, and duplication-method Cox proportional hazards models, we prospectively examined an association between BMI and the incidence of colorectal carcinoma subtypes classified by differentiation features. 120,813 participants were followed for 26 or 32 years and 1528 rectal and colon cancer cases with available tumor pathological data were documented. The association between BMI and colorectal cancer risk significantly differed depending on the presence or absence of poorly-differentiated foci (P heterogeneity  = 0.006). Higher BMI was associated with a higher risk of colorectal carcinoma without poorly-differentiated foci (≥30.0 vs. 18.5-22.4 kg/m 2 : multivariable-adjusted hazard ratio, 1.87; 95% confidence interval, 1.49-2.34; P trend   0.03, with the adjusted α of 0.01). High BMI was associated with risk of colorectal cancer subtype containing no poorly-differentiated focus. Our findings suggest that carcinogenic influence of excess energy balance might be stronger for tumors that retain better intestinal differentiation throughout the tumor areas.

  8. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Chapeau, Cyrille [Biolumine, Biokar Diagnostic, Rue des Quarante Mines ZAC de Ther-Allonne, Beauvais Cedex (France); Bendria, Loubna; Daniel, Philippe [UMR CNRS 6087 LPEC, Universite du Maine, Av Olivier Messiaen, Le Mans cedex 9 (France); Picart, Pascal [UMR CNRS 6613 IAM-LAUM, Ecole Nationale des Ingenieurs du Mans, Universite du Maine, Le Mans Cedex 9 (France)

    2011-05-15

    This research study deals with the on-line detection of heavy metals and toxicity within the context of environmental pollution monitoring. It describes the construction and the proof of concept of a multi-channel bioluminescent bacterial biosensor in immobilized phase: Lumisens3. This new versatile device, designed for the non-stop analysis of water pollution, enables the insertion of any bioluminescent strains (inducible or constitutive), immobilized in a multi-well removable card. The technical design of Lumisens3 has benefited from both a classical and a robust approach and includes four main parts: (1) a dedicated removable card contains 64 wells, 3 mm in depth, arranged in eight grooves within which bacteria are immobilized, (2) this card is incubated on a Pelletier block with a CCD cooled camera on top for bioluminescence monitoring, (3) a fluidic network feeds the card with the sample to be analyzed and finally (4) a dedicated computer interface, BIOLUX 1.0, controls all the elements of the biosensor, allowing it to operate autonomously. The proof of concept of this biosensor was performed using a set of four bioluminescent bacteria (Escherichia coli DH1 pBzntlux, pBarslux, pBcoplux, and E. coli XL1 pBfiluxCDABE) in the on-line detection of CdCl{sub 2} 0.5 {mu}M and As{sub 2}O{sub 3} 5 {mu}M from an influent. When considering metals individually, the ''fingerprints'' from the biosensor were as expected. However, when metals were mixed together, cross reaction and synergistic effects were detected. This biosensor allowed us to demonstrate the simultaneous on-line cross detection of one or several heavy metals as well as the measurement of the overall toxicity of the sample. (orig.)

  9. Acquisition and preliminary analysis of multi-channel seismic reflection data, acquired during the oceanographic cruises of the TOMO-ETNA experiment

    Directory of Open Access Journals (Sweden)

    Marco Firetto Carlino

    2016-09-01

    Full Text Available The TOMO-ETNA experiment was performed in the framework of the FP7 “MED-SUV” (MEDiterranean SUpersite Volcanoes in order to gain a detailed geological and structural model of the continental and oceanic crust concerning Etna and Aeolian Islands volcanoes (Sicily, Italy, by means of active and passive seismic exploration methodologies. Among all data collected, some 1410 km of marine multi-channel seismic (MCS reflection profiles were acquired in the Ionian and Tyrrhenian Seas during two of the three oceanographic cruises of the TOMO-ETNA experiment, in July and November 2014, with the aim of shading light to deep, intermediate and shallow stratigraphy and crustal structure of the two above mentioned areas. The MCS sections, targeted to deep exploration, were acquired during the oceanographic cruise on board the R/V “Sarmiento de Gamboa”, using an active seismic source of 16 air-guns, for a total volume of 4340 cu. in., and a 3000 m long, 240-channels digital streamer as receiving system. High-resolution seismic profiles were instead collected through the R/V “Aegaeo”, using two smaller air-guns (overall 270 cu. in. volume and a 96 channels, 300 m long digital streamer. This paper provides a detailed description of the acquisition parameters and main processing steps adopted for the MCS data. Some processed lines are shown and preliminarily interpreted, to highlight the overall good quality and the high potential of the MCS sections collected during the TOMO-ETNA experiment.

  10. Surface morphology and surface energy of anode materials influence power outputs in a multi-channel mediatorless bio-photovoltaic (BPV) system.

    Science.gov (United States)

    Bombelli, Paolo; Zarrouati, Marie; Thorne, Rebecca J; Schneider, Kenneth; Rowden, Stephen J L; Ali, Akin; Yunus, Kamran; Cameron, Petra J; Fisher, Adrian C; Ian Wilson, D; Howe, Christopher J; McCormick, Alistair J

    2012-09-21

    Bio-photovoltaic cells (BPVs) are a new photo-bio-electrochemical technology for harnessing solar energy using the photosynthetic activity of autotrophic organisms. Currently power outputs from BPVs are generally low and suffer from low efficiencies. However, a better understanding of the electrochemical interactions between the microbes and conductive materials will be likely to lead to increased power yields. In the current study, the fresh-water, filamentous cyanobacterium Pseudanabaena limnetica (also known as Oscillatoria limnetica) was investigated for exoelectrogenic activity. Biofilms of P. limnetica showed a significant photo response during light-dark cycling in BPVs under mediatorless conditions. A multi-channel BPV device was developed to compare quantitatively the performance of photosynthetic biofilms of this species using a variety of different anodic conductive materials: indium tin oxide-coated polyethylene terephthalate (ITO), stainless steel (SS), glass coated with a conductive polymer (PANI), and carbon paper (CP). Although biofilm growth rates were generally comparable on all materials tested, the amplitude of the photo response and achievable maximum power outputs were significantly different. ITO and SS demonstrated the largest photo responses, whereas CP showed the lowest power outputs under both light and dark conditions. Furthermore, differences in the ratios of light : dark power outputs indicated that the electrochemical interactions between photosynthetic microbes and the anode may differ under light and dark conditions depending on the anodic material used. Comparisons between BPV performances and material characteristics revealed that surface roughness and surface energy, particularly the ratio of non-polar to polar interactions (the CQ ratio), may be more important than available surface area in determining biocompatibility and maximum power outputs in microbial electrochemical systems. Notably, CP was readily outperformed by all

  11. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    Science.gov (United States)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  12. HAI: A novel airborne multi-channel hygrometer for fast multi-phase H2O quantification: Performance of the HAI instrument during the first flights on the German HALO aircraft

    Science.gov (United States)

    Buchholz, B.; Ebert, V.; Kraemer, M.; Afchine, A.

    2014-12-01

    Common gas phase H2O measurements on fast airborne platforms e.g. using backward facing or "Rosemount"-inlets can lead to a high risk of ice and droplets contamination. In addition, currently no single hygrometer exists that allows a simultaneous, high-speed measurement of all phases (gas, liquid, ice) with the same detection principle. In the rare occasions multi-phase measurements are realized, gas-and condensed-phase observations rely on different methods, instruments and calibration strategies so that precision and accuracy levels are quite difficult to quantify. This is effectively avoided by the novel TDLAS instrument, HAI, Hygrometer for Atmospheric Investigation, which allows a simultaneous, high speed, multi-phase detection without any sensor calibration in a unique "2+2" channel concept. Hai combines two independent wavelength channels, at 1.4 µm and at 2.6 µm, for a wide dynamic range from 1 to 30 000 ppmv, with a simultaneous closed path (extractive) and open path detection. Thus, "Total", i.e. gas-phase plus condensed-phase water is measured by sampling via a forward facing inlet into "closed-path" extractive cells. A selective, sampling-free, high speed gas phase detection is realized via a dual-wavelength "open-path" cell placed outside of the aircraft fuselage. All channels can be sampled with 120 Hz (measurement cycle time Dt=1.6 ms) allowing an unprecedented spatial resolution of 30 cm at 900 km/h. The evaluation of the individual multi-channel raw-data is done post flight, without any channel interdependencies, in calibration-free mode, thus allowing fast, accurate and precise multi-phase water detection in flight. The performance could be shown in more than 200 net flights hours in three scientific flight campaigns (TACTS, ESMVal, ML-CIRRUS) on the new German HALO aircraft. In addition the level of the accuracy of the calibration free evaluation was evaluated at the German national primary water vapor standard.

  13. Relation of body mass index to risk of stent thrombosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Schmiegelow, Michelle; Torp-Pedersen, Christian; Gislason, Gunnar H

    2012-01-01

    Stent thrombosis is a devastating complication after percutaneous coronary intervention (PCI), but the influence of obesity on risk of stent thrombosis is unclear, and it is unknown if this relation is dependent on stent type. The objective of this study was to examine the relation between body...... mass index (BMI) and stent thrombosis after PCI with bare-metal stent (BMS) or drug-eluting stent (DES). We followed 5,515 patients who underwent PCI with implantation of ≥1 BMS or DES at a high-volume tertiary invasive cardiology center from 2000 through 2006. Only patients with a single type of stent...... (BMS or DES) implanted at the index PCI were included. Median follow-up period was 26 months (interquartile range 12 to 44) and definite stent thrombosis occurred in 78 patients. Hazard ratio of definite stent thrombosis adjusted for number of stents at the index PCI was 0.92 (95% confidence interval...

  14. Visualizing multi-channel networks

    DEFF Research Database (Denmark)

    Antemijczuk, Paweł; Magiera, Marta; Jørgensen, Sune Lehmann

    2014-01-01

    In this paper, we propose a visualization to illustrate social interactions, built from multiple distinct channels of communication. The visualization displays a summary of dense personal information in a compact graphical notation. The starting point is an abstract drawing of a spider’s web. Below...

  15. African genetic ancestry interacts with body mass index to modify risk for uterine fibroids.

    Science.gov (United States)

    Giri, Ayush; Edwards, Todd L; Hartmann, Katherine E; Torstenson, Eric S; Wellons, Melissa; Schreiner, Pamela J; Velez Edwards, Digna R

    2017-07-01

    Race, specifically African ancestry, and obesity are important risk factors for uterine fibroids, and likely interact to provide the right conditions for fibroid growth. However, existing studies largely focus on the main-effects rather than their interaction. Here, we firstly provide evidence for interaction between categories of body mass index (BMI) and reported-race in relation to uterine fibroids. We then investigate whether the association between inferred local European ancestry and fibroid risk is modified by BMI in African American (AA) women in the Vanderbilt University Medical Center bio-repository (BioVU) (539 cases and 794 controls) and the Coronary Artery Risk Development in Young Adults study (CARDIA, 264 cases and 173 controls). We used multiple logistic regression to evaluate interactions between local European ancestry and BMI in relation to fibroid risk, then performed fixed effects meta-analysis. Statistical significance threshold for local-ancestry and BMI interactions was empirically estimated with 10,000 permutations (p-value = 1.18x10-4). Admixture mapping detected an association between European ancestry and fibroid risk which was modified by BMI (continuous-interaction p-value = 3.75x10-5) around ADTRP (chromosome 6p24); the strongest association was found in the obese category (ancestry odds ratio (AOR) = 0.51, p-value = 2.23x10-5). Evaluation of interaction between genotyped/imputed variants and BMI in this targeted region suggested race-specific interaction, present in AAs only; strongest evidence was found for insertion/deletion variant (6:11946435), again in the obese category (OR = 1.66, p-value = 1.72x10-6). We found nominal evidence for interaction between local ancestry and BMI at a previously reported region in chromosome 2q31-32, which includes COL5A2, and TFPI, an immediate downstream target of ADTRP. Interactions between BMI and SNPs (single nucleotide polymorphisms) found in this region in AA women were also detected in an

  16. Can a Modified Bosniak Classification System Risk Stratify Pediatric Cystic Renal Masses?

    Science.gov (United States)

    Saltzman, Amanda F; Carrasco, Alonso; Colvin, Alexandra N; Meyers, Mariana L; Cost, Nicholas G

    2018-03-20

    We characterize and apply the modified Bosniak classification system to a cohort of children with cystic renal lesions and known surgical pathology. We identified all patients at our institution with cystic renal masses who also underwent surgery for these lesions. Patients without available preoperative imaging or pathology were excluded. All radiological imaging was independently reviewed by a pediatric radiologist blinded to pathological findings. Imaging characteristics (size, border, septations, calcifications, solid components, vascularity) were recorded from the most recent preoperative ultrasounds and computerized tomograms. The modified Bosniak classification system was applied to these scans and then correlated with final pathology. A total of 22 patients met study criteria. Median age at surgery was 6.1 years (range 11 months to 16.8 years). Of the patients 12 (54.5%) underwent open nephrectomy, 6 (27.3%) open partial nephrectomy, 2 (9.1%) laparoscopic cyst decortication, 1 (4.5%) open renal biopsy and 1 (4.5%) laparoscopic partial nephrectomy. Final pathology was benign in 9 cases (41%), intermediate in 6 (27%) and malignant in 7 (32%). All malignant lesions were modified Bosniak class 4, all intermediate lesions were modified class 3 or 4 and 8 of 9 benign lesions (89%) were modified class 1 or 2. Cystic renal lesions in children with a modified Bosniak class of 1 or 2 were most often benign, while class 3 or 4 lesions warranted surgical excision since more than 90% of masses harbored intermediate or malignant pathology. The modified Bosniak classification system appears to allow for a reasonable clinical risk stratification of pediatric cystic renal masses. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Notes on a local study on effectiveness and risk of X-ray mass chest screening

    International Nuclear Information System (INIS)

    Barbina, V.; Leonardi, M.

    1987-01-01

    This contribution consists of some special remarks, which may be of general interest, on the results of a local investigation on effectiveness and radiological risk of mass chest screening carried out in Friuli Venezia Giulia, an area of North-East Italy limited by well defined geographical and administrative borders. Population is about 1,300,000, ten percent of which is undergoing X-ray chest screening each year. The results of the study are in the working report of the technical workshop on mass screening organized on 4-5 December 1984 in Luxembourg by CEC and CEA. The study itself does not intend to have any character of generality. It has been proposed as an example of syntetic methodology for other similar local investigations which could possibly constitute a reliable basis for putting together larger ones, of national range, as already mentioned in the report. The conclusions on the results of this study seem obvious to us, however, we are aware that any obvious conclusion must be considered very carefully especially when dealing with a very complex matter as epidemiologic statistic, and particularly if we consider the previous papers on this subject as well as other reports presented in the workshop. Finally, we hope that our remarks may at least contribute as a good background for further discussion

  18. Risk of malignancy index used as a diagnostic tool in a tertiary centre for patients with a pelvic mass

    DEFF Research Database (Denmark)

    Håkansson, Fanny; Høgdall, Estrid V S; Nedergaard, Lotte

    2012-01-01

    Abstract Objective. Risk of malignancy index (RMI), based on a serum cancer antigen 125 level, ultrasound findings and menopausal status, is used to discriminate ovarian cancer from benign pelvic mass. In Denmark, patients with pelvic mass and RMI =200 are referred to tertiary gynecologic oncology...... the use of RMI =200 as a tool for preoperative identification of ovarian cancer at a tertiary center. Design. Prospective observational study. Setting. A tertiary center in Copenhagen, Denmark. Population. One thousand one hundred and fifty-nine women with pelvic mass. Methods. The RMI was calculated...... pelvic mass. Results. There were 778 women diagnosed with benign pelvic mass, while 251 had ovarian cancer and 74 had borderline ovarian tumor. Fifty-six women were diagnosed with other forms of cancer. Sensitivity and specificity for ovarian cancer vs. benign pelvic mass for RMI =200 were 92 and 82...

  19. Assessment of muscle mass, risk of falls and fear of falling in elderly people with diabetic neuropathy

    Directory of Open Access Journals (Sweden)

    Hudson Azevedo Pinheiro

    Full Text Available Abstract Objective : To assess muscle mass, risk of falls and fear of falling in elderly adults with diabetic neuropathy (DNP. Methods : 50 elderly patients with diabetes mellitus (DM and diabetic neuropathy (NPD participated in this study. Risk of falling was assessed using the Berg Balance Scale (BBS. Fear of falling was assessed by means of the Falls Efficacy Scale-International (FES-I. Muscle mass was assessed by tetrapolar bioimpedance analysis (BIA and Janssen's equation. Subjects were divided into two groups: one with a history of falls in the six months before study enrollment (G1 and the other without history of falls (G2. Results : There were statistically significant differences between G1 and G2 regarding lean body mass (p < 0.05, risk of falls as measured by the BBS (p < 0.01, and fear of falling as measured by the FES-I (p < 0.01. In addition, there was a significant correlation between the BBS and BIA (r = 0.45 and p < 0.01, showing that the greater the lean body mass, the lower the risk of falling. Conclusions : We found an association between lean mass, risk of falls and fear of falling in elderly adults with DNP and a history of falls from own height.

  20. Normal Weight but Low Muscle Mass and Abdominally Obese: Implications for the Cardiometabolic Risk Profile in Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    Beijers, Rosanne J H C G; van de Bool, Coby; van den Borst, Bram; Franssen, Frits M E; Wouters, Emiel F M; Schols, Annemie M W J

    2017-06-01

    It is well established that low muscle mass affects physical performance in chronic obstructive pulmonary disease (COPD). We hypothesize that combined low muscle mass and abdominal obesity may also adversely influence the cardiometabolic risk profile in COPD, even in those with normal weight. The cardiometabolic risk profile and the responsiveness to 4 months high-intensity exercise training was assessed in normal-weight patients with COPD with low muscle mass stratified by abdominal obesity. This is a cross-sectional study including 81 clinically stable patients with COPD (age 62.5 ± 8.2 years; 50.6% males; forced expiratory volume in 1 second 55.1 ± 19.5 percentage predicted) with fat-free mass index risk profile. Triglycerides showed a significant decrease, while the HOMA-IR increased. Abdominal obesity is highly prevalent in normal-weight patients with COPD with low muscle mass who showed an increased cardiometabolic risk compared with patients without abdominal obesity. This cardiometabolic risk profile was not altered after 4 months of exercise training. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  1. Relative muscle mass and the risk of incident type 2 diabetes: A cohort study.

    Directory of Open Access Journals (Sweden)

    Sungwoo Hong

    Full Text Available The association between relative muscle mass (RMM and incidence of type 2 diabetes (T2DM is largely unknown. We examined whether RMM predicted development of T2DM in an apparently young healthy population.This cohort study was comprised of 113,913 men and 89,854 women, free of T2DM at baseline, who underwent a health checkup examination and were followed-up annually or biennially for an average of 2.9 years. We used skeletal muscle mass index (SMI as an indicator of RMM. SMI (% [total skeletal muscle mass (kg/body weight (kg×100] was estimated using a bioelectrical impedance analyzer. The study outcome was incident T2DM, defined as fasting serum glucose ≥126 mg/dL, HbA1C ≥6.5%, or use of medication for T2DM.During 589,098.8 person-years of follow-up, 4,264 individuals developed T2DM (incidence rate, 7.2 per 1000 person-years. Median age (range at baseline was 39.1 years (18.1-87.1. RMM was negatively associated with incidence of T2DM in a dose-response manner. The multivariate-adjusted hazard ratios (95% CIs for incident T2DM comparing quartiles 3, 2 and 1 of RMM to the highest quartile were 1.32 (1.14-1.52, 1.63 (1.42-1.86, and 2.21 (1.94-2.51, respectively, for males and 1.18 (0.88-1.58, 1.46 (1.11-1.91, and 1.96 (01.51-2.53 for females (P for trend <0.001; 0.011. This association was stronger in younger or premenopausal subjects.RMM was negatively associated with development of T2DM in a large sample of young and middle-aged Korean adults. Further research is required to determine whether preservation of muscle mass through intervention affects the risk of T2DM.

  2. Body mass index and the risk of dementia among Louisiana low income diabetic patients.

    Directory of Open Access Journals (Sweden)

    Gang Hu

    Full Text Available The association between obesity and dementia risk remains debatable and no studies have assessed this association among diabetic patients. The aim of our study was to investigate the association between body mass index (BMI and dementia risk among middle and low income diabetic patients.The sample included 44,660 diabetic patients (19,618 white and 25,042 African American 30 to 96 years of age without a history of dementia in the Louisiana State University Hospital-Based Longitudinal Study. During a mean follow-up period of 3.9 years, 388 subjects developed incident dementia. The age- and sex-adjusted hazards ratios (HRs for incident dementia at different levels of BMI (≤ 25, 25-26.9, 27-29.9, 30-34.9, and ≥ 35 kg/m(2 were 1.00, 0.53 (95% CI 0.34-0.83, 0.29 (0.18-0.45, 0.37 (0.25-0.56, and 0.31 (0.21-0.48 (P(trend<0.001 in white diabetic patients, and 1.00, 1.00 (95% CI 0.62-1.63, 0.62 (0.39-0.98, 0.56 (0.36-0.86, and 0.65 (0.43-1.01 (P(trend = 0.029 in African American diabetic patients. Further adjustment for other confounding factors affected the results only slightly. There was a significant interaction between race and BMI on dementia risk (χ(2 = 5.52, 1df, p<0.025, such that the association was stronger in white patients. In stratified analyses, the multivariate-adjusted inverse association between BMI and risk of dementia was present in subjects aged 55-64 years, 65-74 years, and ≥ 75 years, in men and women, in non-smokers and smokers, and in subjects with different types of health insurance.Higher baseline BMI was associated with a lower risk of dementia among diabetic patients, and this association was stronger among white than among African American diabetic patients.

  3. Detection of gear cracks in a complex gearbox of wind turbines using supervised bounded component analysis of vibration signals collected from multi-channel sensors

    Science.gov (United States)

    Li, Zhixiong; Yan, Xinping; Wang, Xuping; Peng, Zhongxiao

    2016-06-01

    In the complex gear transmission systems, in wind turbines a crack is one of the most common failure modes and can be fatal to the wind turbine power systems. A single sensor may suffer with issues relating to its installation position and direction, resulting in the collection of weak dynamic responses of the cracked gear. A multi-channel sensor system is hence applied in the signal acquisition and the blind source separation (BSS) technologies are employed to optimally process the information collected from multiple sensors. However, literature review finds that most of the BSS based fault detectors did not address the dependence/correlation between different moving components in the gear systems; particularly, the popular used independent component analysis (ICA) assumes mutual independence of different vibration sources. The fault detection performance may be significantly influenced by the dependence/correlation between vibration sources. In order to address this issue, this paper presents a new method based on the supervised order tracking bounded component analysis (SOTBCA) for gear crack detection in wind turbines. The bounded component analysis (BCA) is a state of art technology for dependent source separation and is applied limitedly to communication signals. To make it applicable for vibration analysis, in this work, the order tracking has been appropriately incorporated into the BCA framework to eliminate the noise and disturbance signal components. Then an autoregressive (AR) model built with prior knowledge about the crack fault is employed to supervise the reconstruction of the crack vibration source signature. The SOTBCA only outputs one source signal that has the closest distance with the AR model. Owing to the dependence tolerance ability of the BCA framework, interfering vibration sources that are dependent/correlated with the crack vibration source could be recognized by the SOTBCA, and hence, only useful fault information could be preserved in

  4. Prepregnancy body mass index and risk of preterm birth: association heterogeneity by preterm subgroups.

    Science.gov (United States)

    Parker, Margaret G; Ouyang, Fengxiu; Pearson, Colleen; Gillman, Matthew W; Belfort, Mandy B; Hong, Xiumei; Wang, Guoying; Heffner, Linda; Zuckerman, Barry; Wang, Xiaobin

    2014-04-30

    To evaluate the association between prepregnancy body mass index (BMI) is associated with early vs. late and medically-induced vs. spontaneous preterm birth (PTB) subtypes. Using data from the Boston Birth Cohort, we examined associations of prepregnancy BMI with 189 early (PTBs and 320 early and 610 late spontaneous PTBs vs. 3281 term births (37-44 weeks) in multinomial regression. To assess for mediation by important pregnancy complications, we performed sequential models with and without hypertensive disorders of pregnancy, chorioamnionitis, and gestational diabetes. Prevalence of prepregnancy obesity (BMI ≥ 30.0 kg/m2) was 28% among mothers with medically-induced PTBs, 18% among mothers with spontaneous PTBs, and 18% among mothers with term births (p = <0.001). After adjustment for demographic and known risk factors for PTB, prepregnancy obesity was associated with higher odds of both early [OR 1.78 (1.19, 2.66)] and late [OR 1.49 (1.09, 2.04)] medically-induced PTB. These effect estimates were attenuated with inclusion of hypertensive disorders of pregnancy and gestational diabetes. For spontaneous deliveries, prepregnancy obesity was associated with decreased odds of PTB (0.76 [0.58, 0.98]) and underweight was nearly associated with increased odds of PTB (1.46 [0.99, 2.16]). Prepregnancy obesity is associated with higher risk of medically-induced, but not spontaneous PTB. Hypertensive disorders of pregnancy and gestational diabetes appear to partially explain the association between prepregnancy obesity and early and late medically-induced PTB.

  5. Low skeletal muscle mass outperforms the Charlson Comorbidity Index in risk prediction in patients undergoing pancreatic resections.

    Science.gov (United States)

    Wagner, D; Marsoner, K; Tomberger, A; Haybaeck, J; Haas, J; Werkgartner, G; Cerwenka, H; Bacher, H; Mischinger, H J; Kornprat, P

    2018-05-01

    Low skeletal muscle mass is a known predictor of morbidity and mortality in patients undergoing major pancreatic surgeries. We sought to combine low skeletal muscle mass with established risk predictors to improve their prognostic capacity for postoperative outcome and morbidity. As established parameters to predict preoperative mortality risk for patients, the ASA classification and the Charlson Comorbidity Index (CCI) were used. The Hounsfield Units Average Calculation (HUAC) was measured to define low skeletal muscle mass in 424 patients undergoing pancreatic resections for malignancies. Patients in the lowest sex-adjusted quartile for HUAC were defined as having low skeletal muscle mass (muscle wasting). Multivariable Cox regression analysis was utilized to identify preoperative risk factors associated with postoperative morbidity. Median patient age was 63 years (19-87), 47.9% patients were male, and half the cohort had multiple comorbidities (Charlson Comorbidity Index [CCI]>6, 63.2%), 30-day mortality was 5.8% (n = 25). Median HUAC was 19.78 HU (IQR: 15.94-23.54) with 145 patients (34.2%) having low skeletal muscle mass. Preoperative frailty defined by low skeletal muscle mass was associated with an increased risk for postoperative complications (OR 1.55, CI 95% 0.98-2.45, p = 0.014), and a higher 30-day mortality (HR 5.17, CI 95% 1.57-16.69, p = 0.004). With an AUC of 0.85 HUAC showed the highest predictability for 30-day mortality (CI 95% 0.78-0.91, p = 0.0001). Patients with CCI ≥6 and low skeletal muscle mass defined by the HUAC had a 9.78 higher risk of dying in the immediate postoperative phase (HR 9.78, CI 95% 2.98-12.2, p = 0.0001). Low skeletal muscle mass predicts postoperative mortality and complications best and it should be incorporated to conventional risk scores to identify high risk patients. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights

  6. Food consumption, body mass index and risk for oral health in adolescents.

    Science.gov (United States)

    Bica, Isabel; Cunha, Madalena; Reis, Margarida; Costa, José; Costa, Patricia; Bica, Alexandra

    2014-11-01

    The food intake has great influence on the oral health of adolescents, being relevant to analyze the type of food consumed by adolescents and their relationship with the DMFT index (decayed, missing and filled), the plaque index (PI) and the body mass index (BMI). Epidemiological study conducted in public schools of the 3rd cycle of basic education, central Portugal. The sociodemographic and dietary habits and frequency characterization was obtained through a self-administered questionnaire completed by adolescents and validated for the population under study. The DMFT index was evaluated according to WHO criteria, oral hygiene was evaluated based on the plaque index and BMI through weight and height in adolescents. Random sample by clusters (schools) with 661 adolescents, 84.1% female and 15.9% male. Adolescents with mean age 13.22 years (± 1.139). The mean DMFT was 2.23 (± 2.484), the prevalence of PI was 96.4%, and ≥ 5 BMI cariogenic foods (r=0.160; P=.000). Adolescents with a higher BMI consume less cariogenic foods (r=-0.1343; P=.001). The value of t reveals that the consumption of cariogenic foods explains 1.8% of the variance of the BMI and 2.6% DMFT. The cariogenic foods are presented as a risk factor for dental caries. The results suggest that it is important to develop up actions for health education. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  7. Body Mass Index: A Risk Factor for Retinopathy in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Snježana Kaštelan

    2013-01-01

    Full Text Available The aim of the study was to investigate whether body mass index (BMI independently or in correlation with other risk factors is associated with diabetic retinopathy (DR progression. The study included 545 patients with type 2 diabetes. According to DR status, they were divided into three groups: group 1 (no retinopathy; n=296, group 2 (mild/moderate nonproliferative DR; n=118, and group 3 (severe/very severe NPDR or proliferative DR; n=131. Patients without DR were younger than those with signs of retinopathy at time of diabetes onset whilst diabetes duration was longer in groups with severe NPDR and PDR. DR progression was correlated with diabetes duration, BMI, HbA1c, hypertension, and cholesterol. Statistical analyses showed that the progression of retinopathy increased significantly with higher BMI (gr. 1: 26.50 ± 2.70, gr. 2: 28.11 ± 3.00, gr. 3: 28.69 ± 2.50; P<0.01. We observed a significant deterioration of HbA1c and a significant increase in cholesterol and hypertension with an increase in BMI. Correlation between BMI and triglycerides was not significant. Thus, BMI in correlation with HbA1c cholesterol and hypertension appears to be associated with the progression of DR in type 2 diabetes and may serve as a predictive factor for the development of this important cause of visual loss in developed countries.

  8. Body Mass Index and Subjective Social Status: The Coronary Artery Risk Development in Young Adults Study.

    Science.gov (United States)

    Dhurandhar, Emily J; Pavela, Gregory; Kaiser, Kathryn A; Dutton, Gareth R; Fontaine, Kevin R; Kim, Daniel; Shikany, James M; Allison, David B; Lewis, Cora E

    2018-02-01

    Subjective social status (SSS), or perceived social status, may explain, in part, the relationship between socioeconomic status (SES) and obesity. The objective of this study was to test whether SSS mediates the relationship between two indicators of SES (income and education) and body mass index (BMI). A cross-sectional, structural equation path analysis was applied to the Coronary Artery Risk Development in Young Adults (CARDIA) study (n = 2,624). The analysis tested whether SSS (MacArthur scale), education, and income were associated with BMI at the year 20 examination (adjusting for sex, age, and race), and it was hypothesized that the associations of education and income with BMI would be at least partly mediated by SSS. SSS had a significant direct effect on BMI (-0.21, P = 0.018). Education had a significant direct relationship with SSS (0.11, P SSS (-0.02, P = 0.022). Although income did not have a significant direct relationship with BMI, it did have a significant indirect relationship through SSS (b = -0.05, P = 0.019). Results are consistent with the hypothesized model in which SSS partially mediates the relationship between SES indicators and BMI. © 2017 The Obesity Society.

  9. Risk of asthma in adult twins with type 2 diabetes and increased body mass index

    DEFF Research Database (Denmark)

    Thomsen, S F; Duffy, D L; Kyvik, K O

    2011-01-01

    . RESULTS: The risk of asthma was increased in subjects with type 2 diabetes relative to nondiabetic subjects both in men (13.5%vs 7.5%), P = 0.001 and in women (16.6%vs 9.6%), P = 0.001. The result remained significant after adjustment for age, BMI, smoking, symptoms of chronic bronchitis, marital status...... asthma and type 2 diabetes, 0.20 (0.01-0.40), P = 0.047; between asthma and BMI in women, 0.15 (0.07-0.22), P type 2 diabetes, 0.40 (0.29-0.43), P type 2 diabetes and increased BMI are strongly associated in adults, particularly in women......AIM: To examine the relationship between asthma, type 2 diabetes and increased body mass index (BMI) in adult twins. METHODS: We performed record linkage between questionnaire-defined asthma and BMI, and hospital discharge diagnoses of type 2 diabetes in 34,782 Danish twins, 20-71 years of age...

  10. Skeletal muscle mass and quality as risk factors for postoperative outcome after open colon resection for cancer

    NARCIS (Netherlands)

    Boer, B. C.; de Graaff, F.; Brusse-Keizer, M.; Bouman, D. E.; Slump, C. H.; Slee-Valentijn, M.; Klaase, J. M.

    The prevalence of colorectal cancer in the elderly is increasing and, therefore, surgical interventions with a risk of potential complications are more frequently performed. This study investigated the role of low skeletal muscle mass (sarcopenia), muscle quality, and the sarcopenic obesity as

  11. Childhood Height and Body Mass Index Were Associated with Risk of Adult Thyroid Cancer in a Large Cohort Study

    DEFF Research Database (Denmark)

    Kitahara, Cari M; Gamborg, Michael; Berrington de González, Amy

    2014-01-01

    Taller stature and obesity in adulthood have been consistently associated with an increased risk of thyroid cancer, but few studies have investigated the role of childhood body size. Using data from a large prospective cohort, we examined associations for height and body mass index (BMI) at ages 7...

  12. Body mass index, height and risk of adenocarcinoma of the oesophagus and gastric cardia: A prospective cohort study

    NARCIS (Netherlands)

    Merry, A.H.H.; Schouten, L.J.; Goldbohm, R.A.; Brandt, P.A. van den

    2007-01-01

    Background: In the last decades, the incidence of oesophageal and gastric cardia adenocarcinoma has increased rapidly in the Western world. We investigated the association between body mass index (BMI), height and risk of oesophageal and gastric cardia adenocarcinoma. Methods: The Netherlands Cohort

  13. Maternal Body Mass Index in Early Pregnancy and Risk of Epilepsy in Offspring.

    Science.gov (United States)

    Razaz, Neda; Tedroff, Kristina; Villamor, Eduardo; Cnattingius, Sven

    2017-06-01

    There is growing concern about the long-term neurologic effects of prenatal exposure to maternal overweight and obesity. The causes of epilepsy are poorly understood and, in more than 60% of the patients, no definitive cause can be determined. To investigate the association between early pregnancy body mass index (BMI) and the risk of childhood epilepsy and examine associations between obesity-related pregnancy and neonatal complications and risks of childhood epilepsy. A population-based cohort study of 1 441 623 live single births at 22 or more completed gestational weeks in Sweden from January 1, 1997, to December 31, 2011, was conducted. The diagnosis of epilepsy as well as obesity-related pregnancy and neonatal complications were based on information from the Sweden Medical Birth Register and National Patient Register. Multivariate Cox proportional hazards regression models were used to estimate adjusted hazard ratios (HRs) and 95% CIs after adjusting for maternal age, country of origin, educational level, cohabitation with partner, height, smoking, maternal epilepsy, and year of delivery. Data analysis was conducted from June 1 to December 15, 2016. Risk of childhood epilepsy. Of the 1 421 551 children born between January 1, 1997, and December 31, 2011, with covariate information available, 7592 (0.5%) were diagnosed with epilepsy through December 31, 2012. Of these 3530 (46.5%) were female. The overall incidence of epilepsy in children aged 28 days to 16 years was 6.79 per 10 000 child-years. Compared with offspring of normal-weight mothers (BMI 18.5 to epilepsy by maternal BMI categories were as follows: overweight (BMI 25.0 to epilepsy were considerably increased for children with malformations of the nervous system (adjusted HR, 46.4; 95% CI, 42.2-51.0), hypoxic ischemic encephalopathy (adjusted HR, 23.6; 95% CI, 20.6-27.1), and neonatal convulsions (adjusted HR, 33.5; 95% CI, 30.1-37.4). The rates of epilepsy were doubled among children with

  14. Getting ready for the marriage market? The association between divorce risks and investments in attractive body mass among married Europeans.

    Science.gov (United States)

    Lundborg, Petter; Nystedt, Paul; Lindgren, Björn

    2007-07-01

    This article explores to what extent married middle-aged individuals in Europe are governed by the risk of experiencing divorce, when shaping their physical appearance. The main result is that divorce risks, proxied by national divorce rates, are negatively connected to body mass index (BMI) among married individuals but unrelated to BMI among singles. Hence, it seems that married people in societies where divorce risks are high are more inclined to invest in their outer appearance. One interpretation is that high divorce rates make married people prepare for a potential divorce and future return to the marriage market.

  15. Risk of catecholaminergic crisis following glucocorticoid administration in patients with an adrenal mass: a literature review.

    Science.gov (United States)

    Barrett, Catherine; van Uum, Stan H M; Lenders, Jacques W M

    2015-11-01

    Glucocorticoids as diagnostic or therapeutic agents have been reported to carry an increased risk of catecholaminergic crisis (CC) in patients with pheochromocytoma or paraganglioma (PPGL). We searched literature databases using the following terms: pheochromocytoma, paraganglioma, adrenal incidentaloma, steroids, glucocorticoids, dexamethasone suppression test (DST), hypertensive crisis, cosyntropin and CRH. From all published case reports (1962-2013), we reviewed medical history, presenting symptoms, dose and route of steroid administration, location and size of adrenal mass, biochemical phenotype and outcome. Twenty-five case reports describing a CC were identified. Three patients with an adrenal incidentaloma suffered a CC following high-dose DST, and in one case, this was fatal. In two of these patients, biochemical testing missed the diagnosis, and in the third, a DST was done despite elevated urinary metanephrines. No CC has been reported for patients undergoing a low-dose DST. Three of 16 patients who received therapeutic glucocorticoids and four of six patients following cosyntropin testing died. No specific biochemical phenotype was related to adverse events. Although a causal relationship cannot be established from this review, it seems prudent to exclude a PPGL in patients with a large incidentaloma or when high-dose DST is considered in a patient with an incidentaloma of any size. Our literature review does not support the need for biochemical testing for PPGL prior to a low-dose (1 mg) DST. Finally, before starting therapeutic glucocorticoids, any clinical signs or symptoms of a potential PPGL should prompt reliable biochemical testing to rule out a PPGL. © 2015 John Wiley & Sons Ltd.

  16. Interaction of a genetic risk score with physical activity, physical inactivity, and body mass index in relation to venous thromboembolism risk.

    Science.gov (United States)

    Kim, Jihye; Kraft, Peter; Hagan, Kaitlin A; Harrington, Laura B; Lindstroem, Sara; Kabrhel, Christopher

    2018-06-01

    Venous thromboembolism (VTE) is highly heritable. Physical activity, physical inactivity and body mass index (BMI) are also risk factors, but evidence of interaction between genetic and environmental risk factors is limited. Data on 2,134 VTE cases and 3,890 matched controls were obtained from the Nurses' Health Study (NHS), Nurses' Health Study II (NHS II), and Health Professionals Follow-up Study (HPFS). We calculated a weighted genetic risk score (wGRS) using 16 single nucleotide polymorphisms associated with VTE risk in published genome-wide association studies (GWAS). Data on three risk factors, physical activity (metabolic equivalent [MET] hours per week), physical inactivity (sitting hours per week) and BMI, were obtained from biennial questionnaires. VTE cases were incident since cohort inception; controls were matched to cases on age, cohort, and genotype array. Using conditional logistic regression, we assessed joint effects and interaction effects on both additive and multiplicative scales. We also ran models using continuous wGRS stratified by risk-factor categories. We observed a supra-additive interaction between wGRS and BMI. Having both high wGRS and high BMI was associated with a 3.4-fold greater risk of VTE (relative excess risk due to interaction = 0.69, p = 0.046). However, we did not find evidence for a multiplicative interaction with BMI. No interactions were observed for physical activity or inactivity. We found a synergetic effect between a genetic risk score and high BMI on the risk of VTE. Intervention efforts lowering BMI to decrease VTE risk may have particularly large beneficial effects among individuals with high genetic risk. © 2018 WILEY PERIODICALS, INC.

  17. Relationship between US Societal Fatality Risk per Vehicle Miles of Travel and Mass, for Individual Vehicle Models over Time (Model Year)

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Tom P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Technologies Area. Building Technology and Urban Systems Division

    2016-07-27

    This report presents a new approach to analyze the relationship between vehicle mass and risk: tracking fatality risk by vehicle model year and mass, for individual vehicle models. This approach is appealing as it greatly minimizes the influence of driver characteristics and behavior, and crash circumstances, on fatality risk. However, only the most popular vehicle models, with the largest number of fatalities, can be analyzed in this manner. While the analysis of all vehicle models of a given type suggests that there is a relationship between increased mass and fatality risk, analysis of the ten most popular four-door car models separately suggests that this relationship is weak: in many cases when the mass of a specific vehicle model is increased societal fatality risk is unchanged or even increases. These results suggest that increasing the mass of an individual vehicle model does not necessarily lead to decreased societal fatality risk.

  18. Geographic origin as a determinant of left ventricular mass and diastolic function - the Cardiovascular Risk in Young Finns Study.

    Science.gov (United States)

    Vähämurto, L; Juonala, M; Ruohonen, S; Hutri-Kähönen, N; Kähönen, M; Laitinen, T; Tossavainen, P; Jokinen, E; Viikari, J; Raitakari, O T; Pahkala, K

    2018-03-01

    Eastern Finns have higher risk of coronary heart disease (CHD) and carotid intima-media thickness than western Finns although current differences in CHD risk factors are minimal. Left ventricular (LV) mass and diastolic function predict future cardiovascular events but their east-west differences are unknown. We examined the association of eastern/western baseline origin with LV mass and diastolic function. The study population included 2045 subjects of the Cardiovascular Risk in Young Finns Study with data from the baseline survey (1980) and the latest follow-up (2011) when echocardiography was performed at the age of 34-49 years. Subjects with eastern baseline origin had in 2011 higher LV mass (139±1.0 vs. 135±1.0 g, p=0.006) and E/e'-ratio indicating weaker LV diastolic function (4.86±0.03 vs. 4.74±0.03, p=0.02) than western subjects. Results were independent of age, sex, area of examination and CHD risk factors such as blood pressure and BMI (LV mass indexed with height: porigin (135±0.9 vs. 131±0.9 ml, p=0.0011) but left atrial end-systolic volume, also indicating LV diastolic function, was not different between eastern and western subjects (43.4±0.5 vs. 44.0±0.5 ml, p=0.45). Most of the subjects were well within the normal limits of these echocardiographic measurements. In our healthy middle-aged population, geographic origin in eastern Finland associated with higher LV mass compared to western Finland. Higher E/e'-ratio suggests that subjects with eastern baseline origin might have higher prevalence of diastolic dysfunction in the future than western subjects.

  19. Effects of exercise improves muscle strength and fat mass in patients with high fracture risk: A randomized control trial

    Directory of Open Access Journals (Sweden)

    Ding-Cheng Chan

    2018-07-01

    Full Text Available Background: The deterioration of the musculoskeletal system imposes significant impact on physical activity. Exercise is an important strategy which minimizes these changes. It is not clear which type of exercise provides better improvement on low physical performance, low muscle mass and low strength of sarcopenia. We aim to develop an integrated care (IC model and compare its relative efficacy in limb fat free mass, muscle strength, and physical performance with low extremities exercise (LEE in community dwelling older adults with high risk of fractures (Fracture Risk Assessment Tool (FRAX® ≧3% for hip fracture, ≧20% for major osteoporotic fracture or 1-min osteoporosis risk test (≧1 point or fall (≧2 falls in previous year. Methods: Patients were assigned randomized to participate in either IC or LEE group (n = 55 each for 3 months. All participants received education including home-based exercise. The IC group consisted of different modalities of exercise while the LEE group performed machine-based low extremities exercise. Fat free mass, muscle strength, and physical performance were measured at their baseline and 3-months follow-up. Results: Mean age was 73.8 ± 7 years with 69.1% women. Entire cohort demonstrated significant increment in fat free mass, muscle strength (4 indicators and physical performance (3 indicators. However, between group differences were not significant. Conclusion: With regular supervise exercise; both groups are equally effective in decreasing fat mass and increasing physical performance, muscle mass and strength. However, the IC group required fewer resources and thus more financially feasible in a community setting. Keywords: Bone mineral density, Gender differences, Integrated care, Low extremities exercise, Muscle strength

  20. Effects of exercise improves muscle strength and fat mass in patients with high fracture risk: A randomized control trial.

    Science.gov (United States)

    Chan, Ding-Cheng; Chang, Chirn-Bin; Han, Der-Sheng; Hong, Cian-Hui; Hwang, Jawl-Shan; Tsai, Keh-Sung; Yang, Rong-Sen

    2017-10-26

    The deterioration of the musculoskeletal system imposes significant impact on physical activity. Exercise is an important strategy which minimizes these changes. It is not clear which type of exercise provides better improvement on low physical performance, low muscle mass and low strength of sarcopenia. We aim to develop an integrated care (IC) model and compare its relative efficacy in limb fat free mass, muscle strength, and physical performance with low extremities exercise (LEE) in community dwelling older adults with high risk of fractures (Fracture Risk Assessment Tool (FRAX ® )) ≧3% for hip fracture, ≧20% for major osteoporotic fracture or 1-min osteoporosis risk test (≧1 point) or fall (≧2 falls in previous year). Patients were assigned randomized to participate in either IC or LEE group (n = 55 each) for 3 months. All participants received education including home-based exercise. The IC group consisted of different modalities of exercise while the LEE group performed machine-based low extremities exercise. Fat free mass, muscle strength, and physical performance were measured at their baseline and 3-months follow-up. Mean age was 73.8 ± 7 years with 69.1% women. Entire cohort demonstrated significant increment in fat free mass, muscle strength (4 indicators) and physical performance (3 indicators). However, between group differences were not significant. With regular supervise exercise; both groups are equally effective in decreasing fat mass and increasing physical performance, muscle mass and strength. However, the IC group required fewer resources and thus more financially feasible in a community setting. Copyright © 2017. Published by Elsevier B.V.

  1. Prospect theory and body mass: characterizing psychological parameters for weight-related risk attitudes and weight-gain aversion.

    Science.gov (United States)

    Lim, Seung-Lark; Bruce, Amanda S

    2015-01-01

    We developed a novel decision-making paradigm that allows us to apply prospect theory in behavioral economics to body mass. 67 healthy young adults completed self-report measures and two decision-making tasks for weight-loss, as well as for monetary rewards. We estimated risk-related preference and loss aversion parameters for each individual, separately for weight-loss and monetary rewards choice data. Risk-seeking tendency for weight-loss was positively correlated with body mass index in individuals who desired to lose body weight, whereas the risk-seeking for momentary rewards was not. Risk-seeking for weight-loss was correlated to excessive body shape preoccupations, while aversion to weight-gain was correlated with self-reports of behavioral involvement for successful weight-loss. We demonstrated that prospect theory can be useful in explaining the decision-making process related to body mass. Applying prospect theory is expected to advance our understanding of decision-making mechanisms in obesity, which might prove helpful for improving healthy choices.

  2. Prospect theory and body mass: Characterizing psychological parameters for weight-related risk attitudes and weight-gain aversion

    Directory of Open Access Journals (Sweden)

    Seung-Lark eLim

    2015-03-01

    Full Text Available We developed a novel decision-making paradigm that allows us to apply prospect theory in behavioral economics to body mass. 67 healthy young adults completed self-report measures and two decision-making tasks for weight-loss, as well as for monetary rewards. We estimated risk-related preference and loss aversion parameters for each individual, separately for weight-loss and monetary rewards choice data. Risk-seeking tendency for weight-loss was positively correlated with body mass index in individuals who desired to lose body weight, whereas the risk-seeking for momentary rewards was not. Risk-seeking for weight-loss was correlated to excessive body shape preoccupations, while aversion to weight-gain was correlated with self-reports of behavioral involvement for successful weight-loss. We demonstrated that prospect theory can be useful in explaining the decision-making process related to body mass. Applying prospect theory is expected to advance our understanding of decision-making mechanisms in obesity, which might prove helpful for improving healthy choices.

  3. Factors influencing public risk-benefit considerations of nanotechnology: Assessing the effects of mass media, interpersonal communication, and elaborative processing.

    Science.gov (United States)

    Ho, Shirley S; Scheufele, Dietram A; Corley, Elizabeth A

    2013-07-01

    This study examines the influence of mass media, interpersonal communication, and elaborative processing on public perception of benefits and risks of nanotechnology, based on a large-scale nationally representative telephone survey of U.S. adult citizens. Results indicate that cognitive processes in the form of news elaboration had a significant positive main effect on benefits outweigh risks perception. The influences of attention to science in newspapers, attention to science news on television, and interpersonal communication about science on public perception of benefits outweigh risks were moderated by elaborative processing, after controlling for socio-demographic variables, religious beliefs, trust in scientists, and scientific knowledge. The findings highlight the importance of elaborative processing when it comes to understanding how the mass media differentially influence public benefits outweigh risks perception of emerging technologies. Specifically, high elaborative processing emphasizes higher levels of perceived benefits outweigh risks than low elaborative processing. This study explores explanations for this phenomenon and offers implications for future research and policy.

  4. Association of body mass index with amnestic and non-amnestic mild cognitive impairment risk in elderly.

    Science.gov (United States)

    Wang, Feng; Zhao, Minghui; Han, Zhaoli; Li, Dai; Zhang, Shishuang; Zhang, Yongqiang; Kong, Xiaodong; Sun, Ning; Zhang, Qiang; Lei, Ping

    2017-09-15

    Previous studies focused on the relationship between body mass index and cognitive disorder and obtained many conflicting results. This study explored the potential effects of body mass index on the risk of mild cognitive impairment (amnestic and non-amnestic) in the elderly. The study enrolled 240 amnestic mild cognitive impairment patients, 240 non-amnestic mild cognitive impairment patients and 480 normal cognitive function controls. Data on admission and retrospective data at baseline (6 years ago) were collected from their medical records. Cognitive function was evaluated using Mini-Mental State Examination and Montreal Cognitive Assessment. Being underweight, overweight or obese at baseline was associated with an increased risk of amnestic mild cognitive impairment (OR: 2.30, 95%CI: 1.50 ~ 3.52; OR: 1.74, 95%CI: 1.36 ~ 2.20; OR: 1.71, 95%CI: 1.32 ~ 2.22, respectively). Being overweight or obese at baseline was also associated with an increased risk of non-amnestic mild cognitive impairment (OR: 1.51, 95%CI: 1.20 ~ 1.92; OR: 1.52, 95%CI: 1.21 ~ 1.97, respectively). In subjects with normal weights at baseline, an increased or decreased body mass index at follow-up was associated with an elevated risk of amnestic mild cognitive impairment (OR: 1.80, 95%CI: 1.10 ~ 3.05; OR: 3.96, 95%CI: 2.88 ~ 5.49, respectively), but only an increased body mass index was associated with an elevated risk of non-amnestic mild cognitive impairment (OR: 1.71, 95%CI: 1.16 ~ 2.59). Unhealthy body mass index levels at baseline and follow-up might impact the risk of both types of mild cognitive impairment (amnestic and non-amnestic).

  5. Effect of Using Different Vehicle Weight Groups on the Estimated Relationship Between Mass Reduction and U.S. Societal Fatality Risk per Vehicle Miles of Travel

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Tom P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Technologies Area. Building Technology and Urban Systems Division

    2016-08-22

    This report recalculates the estimated relationship between vehicle mass and societal fatality risk, using alternative groupings by vehicle weight, to test whether the trend of decreasing fatality risk from mass reduction as case vehicle mass increases, holds over smaller increments of the range in case vehicle masses. The NHTSA baseline regression model estimates the relationship using for two weight groups for cars and light trucks; we re-estimated the mass reduction coefficients using four, six, and eight bins of vehicle mass. The estimated effect of mass reduction on societal fatality risk was not consistent over the range in vehicle masses in these weight bins. These results suggest that the relationship indicated by the NHTSA baseline model is a result of other, unmeasured attributes of the mix of vehicles in the lighter vs. heavier weight bins, and not necessarily the result of a correlation between mass reduction and societal fatality risk. An analysis of the average vehicle, driver, and crash characteristics across the various weight groupings did not reveal any strong trends that might explain the lack of a consistent trend of decreasing fatality risk from mass reduction in heavier vehicles.

  6. Limb/trunk lean mass ratio as a risk factor for mortality in peritoneal dialysis patients

    OpenAIRE

    Hui Kang, Seok; Hyang Cho, Kyu; Won Park, Jong; Woo Yoon, Kyung; Young Do, Jun

    2012-01-01

    Protein energy wasting (PEW) is a common problem in dialysis patients. There have been few reports on the effects of regional lean mass distribution for peritoneal dialysis (PD) patients. We reviewed the medical records and identified all adults who received PD between May 2001 and May 2011. Five hundred thirty four patients were enrolled. The clinical and laboratory data were collected at 1 and 12 months. Regional lean masses were measured by dual-energy X-ray absorptiometry. The limb/trunk ...

  7. Neurodevelopmental and psychosocial risk factors in serial killers and mass murderers

    OpenAIRE

    Allely, Clare S.; Minnis, Helen; Thompson, Lucy; Wilson, Philip; Gillberg, Christopher

    2014-01-01

    Multiple and serial murders are rare events that have a very profound societal impact. We have conducted a systematic review, following PRISMA guidelines, of both the peer reviewed literature and of journalistic and legal sources regarding mass and serial killings. Our findings tentatively indicate that these extreme forms of violence may be a result of a highly complex interaction of biological, psychological and sociological factors and that, potentially, a significant proportion of mass or...

  8. Sarcopenia is a risk factor for elevated aminotransferase in men independently of body mass index, dietary habits, and physical activity.

    Science.gov (United States)

    Yoo, Ki Deok; Jun, Dae Won; Lee, Kang Nyeong; Lee, Hang Lak; Lee, Oh Young; Yoon, Byung Chul; Choi, Ho Soon

    2015-04-01

    Aminotransferase activity is a surrogate marker of liver injury showing strong correlations with obesity and metabolic syndrome. However, elevated aminotransferase activity is not uncommon in non-obese and non-alcoholic patients in clinical practice. To examine the relationship between sarcopenia and aminotransferase activity in a large population-based cohort. Data from the Korean National Health and Nutrition Examinations were used. A total of 13,431 subjects were included. A whole-body dual X-ray absorptiometry scan was performed on each patient to measure total and regional muscle mass. Appendicular skeletal muscle mass indices were also obtained. The prevalence of sarcopenia was significantly higher in the group with elevated aminotransferase levels than in the normal liver enzyme group (males: 26.5% vs. 16.9%; females: 38.3% vs. 22.1%, plevels. The frequency of elevated aminotransferase increased in male patients with sarcopenia after adjusting for potential confounding factors including age, body mass index, fasting glucose level, dietary, and exercise habits. However, the correlation was no longer observed in women after adjusting for body mass index. Sarcopenia is a risk factor for elevated aminotransferase in men, independently of body mass index, dietary habits, and physical activity. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  9. Call to claim your prize: Perceived benefits and risk drive intention to comply in a mass marketing scam.

    Science.gov (United States)

    Wood, Stacey; Liu, Pi-Ju; Hanoch, Yaniv; Xi, Patricia M; Klapatch, Lukas

    2018-06-01

    Mass marketing scams extract an enormous toll, yet the literature on scams is just emerging. In Experiment 1, 211 adults reviewed a solicitation and rated their intention of contacting an "activation number" for a prize. Scarcity and authority were manipulated. Many (48.82%) indicated some willingness to contact to "activate" the winnings. Intention of responding was inversely related to the perception of risk (b = -.441, p < .001) and positively associated with perception of benefits (b = .554, p < .001), but not with the experimental condition. In Experiment 2, 291 adults were randomly assigned to one of the three conditions (low, medium, or high activation fee), and were asked to report willingness to contact. Activation fees decreased intent to contact, but percentages remained high (25.70%), with higher perception of risk reducing contact rates (b = -.581, p < .001), and benefit perception increasing intent to contact (b = .381, p < .001). Our studies indicate that consumers are responding to perceived risks and benefits in their decision-making, regardless of persuasion elements used by scammers. In summary, our studies find that consumers with lower levels of education and high perception of benefits are at increased risk for mass marketing scams. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  10. The influence of body mass index, age and sex on inflammatory disease risk in semi-captive Chimpanzees.

    Directory of Open Access Journals (Sweden)

    Vincent Obanda

    Full Text Available Obesity and ageing are emerging issues in the management of captive primates, including Chimpanzees, Pan troglodytes. Studies on humans show that obesity and old age can independently increase the risk of inflammatory-associated diseases indicated by elevated levels of pro-inflammatory cells and proteins in the blood of older or obese compared to levels in younger or non-obese individuals. In humans, sex can influence the outcomes of these risks. Health management of these problems in chimpanzee populations requires an understanding of similarities and differences of factors influencing inflammatory disease risks in humans and in chimpanzees. We examined the relationship between age, sex and Body Mass Index (BMI with hematological biomarkers of inflammatory disease risk established for humans which include the neutrophil to lymphocyte ratio (NLR, and neutrophil, white blood cell (WBC, platelet microparticle and platelet counts. We found that higher values of NLR, neutrophil count and platelet microparticle count were associated with higher BMI values and older age indicating increased inflammation risk in these groups; a similar pattern to humans. There was a strong sex by age interaction on inflammation risk, with older males more at risk than older females. In contrast to human studies, total WBC count was not influenced by BMI, but like humans, WBC and platelet counts were lower in older individuals compared to younger individuals. Our findings are similar to those of humans and suggest that further insight on managing chimpanzees can be gained from extensive studies of ageing and obesity in humans. We suggest that managing BMI should be an integral part of health management in captive chimpanzee populations in order to partially reduce the risk of diseases associated with inflammation. These results also highlight parallels in inflammation risk between humans and chimpanzees and have implications for understanding the evolution of

  11. Education and inequalities in risk scores for coronary heart disease and body mass index: evidence for a population strategy.

    Science.gov (United States)

    Liu, Sze Yan; Kawachi, Ichiro; Glymour, M Maria

    2012-09-01

    Concerns have been raised that education may have greater benefits for persons at high risk of coronary heart disease (CHD) than for those at low risk. We estimated the association of education (less than high school, high school, or college graduates) with 10-year CHD risk and body mass index (BMI), using linear and quantile regression models, in the following two nationally representative datasets: the 2006 wave of the Health and Retirement Survey and the 2003-2008 National Health and Nutrition Examination Survey (NHANES). Higher educational attainment was associated with lower 10-year CHD risk for all groups. However, the magnitude of this association varied considerably across quantiles for some subgroups. For example, among women in NHANES, a high school degree was associated with 4% (95% confidence interval = -9% to 1%) and 17% (-24% to -8%) lower CHD risk in the 10th and 90th percentiles, respectively. For BMI, a college degree was associated with uniform decreases across the distribution for women, but with varying increases for men. Compared with those who had not completed high school, male college graduates in the NHANES sample had a BMI that was 6% greater (2% to 11%) at the 10th percentile of the BMI distribution and 7% lower (-10% to -3%) at the 90th percentile (ie, overweight/obese). Estimates from the Health and Retirement Survey sample and the marginal quantile regression models showed similar patterns. Conventional regression methods may mask important variations in the associations between education and CHD risk.

  12. Interactive effect of genetic susceptibility with height, body mass index, and hormone replacement therapy on the risk of breast cancer

    Directory of Open Access Journals (Sweden)

    Harlid Sophia

    2012-06-01

    Full Text Available Abstract Background Breast cancer today has many established risk factors, both genetic and environmental, but these risk factors by themselves explain only part of the total cancer incidence. We have investigated potential interactions between certain known genetic and phenotypic risk factors, specifically nine single nucleotide polymorphisms (SNPs and height, body mass index (BMI and hormone replacement therapy (HRT. Methods We analyzed samples from three different study populations: two prospectively followed Swedish cohorts and one Icelandic case–control study. Totally 2884 invasive breast cancer cases and 4508 controls were analysed in the study. Genotypes were determined using Mass spectrometry-Maldi-TOF and phenotypic variables were derived from measurements and/or questionnaires. Odds Ratios and 95% confidence intervals were calculated using unconditional logistic regression with the inclusion of an interaction term in the logistic regression model. Results One SNP (rs851987 in ESR1 tended to interact with height, with an increasingly protective effect of the major allele in taller women (p = 0.007 and rs13281615 (on 8q24 tended to confer risk only in non users of HRT (p-for interaction = 0.03. There were no significant interactions after correction for multiple testing. Conclusions We conclude that much larger sample sets would be necessary to demonstrate interactions between low-risk genetic polymorphisms and the phenotypic variables height, BMI and HRT on the risk for breast cancer. However the present hypothesis-generating study has identified tendencies that would be of interest to evaluate for gene-environment interactions in independent materials.

  13. Risk factors for ocular infection with Chlamydia trachomatis in children 6 months following mass treatment in Tanzania.

    Directory of Open Access Journals (Sweden)

    Luis Carlos Cajas-Monson

    2011-03-01

    Full Text Available Trachoma is the leading infectious cause of blindness in the world, and for endemic communities, mass treatment with azithromycin reduces the pool of infection. High coverage is essential, especially in children as they are the infectious reservoir. However, infection remains post-mass treatment. We sought to determine risk factors for infection in children post-mass treatment.All children under 9 years in 4 villages in Tanzania were followed from baseline pre-mass treatment to six months post treatment. 1,991 children under nine years were enrolled in the longitudinal study and data on individual and household characteristics was collected at baseline. Clinical trachoma was determined by an ocular exam and infection detected by PCR of an eyelid swab. Azithromycin was offered and infection was reassessed at 6 months. A multilevel logistic regression model was used, accounting for household clustering of children for analysis.Baseline infection was 23.7% and at 6 months was 10.4%, despite 95% coverage. Infection at baseline was positively associated with infection at 6 months (OR = 3.31, 95%CI 2.40-4.56 and treatment had a protective effect (OR = 0.45, 95%CI 0.25-0.80. The age group 2-4 years had an increased risk of infection at 6 months. The household characteristics predictive of infection at 6 months were increasing number of children infected in the household at baseline and increasing number of untreated children in the household.While one round of mass treatment with high coverage did decrease infection by over 50%, it appears that it is not sufficient to eliminate infection. Findings that young children (ages 2-4 years and households with increasing numbers of infected and untreated children have a positive association with infection at 6 months suggest that such households could be targeted for more intensive follow up.

  14. Childhood body mass index and the risk of prostate cancer in adult men

    DEFF Research Database (Denmark)

    Aarestrup, J; Gamborg, M; Cook, M B

    2014-01-01

    BACKGROUND: Prostate cancer aetiology is poorly understood. It may have origins early in life; previously we found a positive association with childhood height. The effects of early life body mass index (BMI; kg m(-2)) on prostate cancer remain equivocal. We investigated if childhood BMI...... to the Danish Cancer Registry. Cox proportional hazards regressions were performed. RESULTS: Overall, 3355 men were diagnosed with prostate cancer. Body mass index during childhood was positively associated with adult prostate cancer. The hazard ratio of prostate cancer was 1.06 (95% confidence interval (CI): 1...

  15. Weight, height, body mass index and risk of breast cancer in postmenopausal women: a case-control study

    Directory of Open Access Journals (Sweden)

    Vahdaninia Mariam

    2008-09-01

    Full Text Available Abstract Background Many women in Iran have a relatively high body mass index. To investigate whether the condition contributes to excess breast cancer cases, a case-control study was conducted to assess the relationships between anthropometric variables and breast cancer risk in Tehran, Iran. Methods All incident cases of breast cancer in the Iranian Centre for Breast Cancer (ICBC were identified through the case records. Eligible cases were all postmenopausal women with histological confirmed diagnosis of breast cancer during 1996 to year 2000. Controls were randomly selected postmenopausal women attending the ICBC for clinical breast examination during the same period. The body mass index (BMI was calculated based on weights and heights as measured by the ICBC nursing staff. Both tests for trend and logistic regression analysis were performed to calculate odds ratios and 95% confidence intervals as measures of relative risk. Results In all, 116 breast cancer cases and 116 controls were studied. There were no significant differences between cases and control with regard to most independent variables studied. However, a significant difference was observed between cases and controls indicating that the mean BMI was higher in cases as compared to controls (P = 0.004. Performing logistic regression analysis while controlling for age, age at menopause, family history of breast cancer and parity, the results showed that women with a BMI in the obese range had a three fold increased risk of breast cancer [odds ratio (OR = 3.21, 95% confidence interval (CI: 1.15–8.47]. Conclusion The results suggest that obesity in postmenopausal women could increase risk of breast cancer and it merits further investigation in populations such as Iran where it seems that many women are short in height, and have a relatively high body mass index.

  16. Bone Mass Density and Risk of Breast Cancer and Survival in Older Women

    International Nuclear Information System (INIS)

    Ganry, O.; Baudoin, C.; Fardellone, P.; Peng, J.; Raverdy, N.

    2004-01-01

    Study objective: Older women with high bone mineral density (BMD) have an increased risk of breast cancer but it is not well known whether this association is associated with the stage of the tumor. The objective of the study is to determine if older women with high BMD are likely to develop a more aggressive form of breast cancer, as defined by mortality. Patients: We prospectively studied 1504 women who were 75 years of age or older at the entry in the study (range, 75-90 years), between 1992 and 1994. BMD was measured by dual-photon X-ray absorptiometry at three skeletal sites (trochanter, Ward's triangle, femoral neck). The women were followed for a mean of 7 years for the occurrence of breast cancer. Cox proportional-hazards models were used to obtain estimates of the relative risk of breast cancer and relative risk of death according to the BMD. Main results: Forty-five incident breast cancer cases were identified. In multivariate analyses of the risk of breast cancer for women in the highest tertile of BMD was greater than for women in the lowest tertile. Indeed, the women with a trochanter BMD in the highest tertile were at 2.3-fold increased risk compared with women in the lowest tertile. The women with highest tertile BMD measured at the Ward's triangle and at the femoral neck were respectively at 2.2-and 3.3-fold increased risk compared with women at the lowest risk. The 7-year survival rates were markedly less favorable for women in the second and third tertile of the three skeletal sites compared with the lowest tertile. The risk of death was greater for women in the highest tertile of BMD than for women in the lowest tertile at every skeletal site. Conclusion: Elderly women with high BMD have an increased risk of breast cancer, especially advanced cancer, compared with women with low BMD

  17. Risk of catecholaminergic crisis following glucocorticoid administration in patients with an adrenal mass: a literature review

    NARCIS (Netherlands)

    Barrett, C.; Uum, S.H. van; Lenders, J.W.M.

    2015-01-01

    BACKGROUND: Glucocorticoids as diagnostic or therapeutic agents have been reported to carry an increased risk of catecholaminergic crisis (CC) in patients with pheochromocytoma or paraganglioma (PPGL). METHODS: We searched literature databases using the following terms: pheochromocytoma,

  18. Differential predictors of transient stress versus posttraumatic stress disorder: evaluating risk following targeted mass violence.

    Science.gov (United States)

    Miron, Lynsey R; Orcutt, Holly K; Kumpula, Mandy J

    2014-11-01

    Schools have become a common incident site for targeted mass violence, including mass shootings. Although exposure to mass violence can result in significant distress, most individuals are able to fully recover over time, while a minority develop more pervasive pathology, such as PTSD. The present study investigated how several pre- and posttrauma factors predict posttraumatic stress symptoms (PTSS) in both the acute and distal aftermath of a campus mass shooting using a sample with known levels of pretrauma functioning (N=573). Although the largest proportion of participants evidenced resilience following exposure to the event (46.1%), many reported high rates of PTSS shortly after the shooting (42.1%) and a smaller proportion (11.9%) met criteria for probable PTSD both in the acute and more distal aftermath of the event. While several preshooting factors predicted heightened PTSS after the shooting, prior trauma exposure was the only preshooting variable shown to significantly differentiate between those who experienced transient versus prolonged distress. Among postshooting predictors, individuals reporting greater emotion dysregulation and peritraumatic dissociative experiences were over four times more likely to have elevated PTSS 8months postshooting compared with those reporting less dysregulation and dissociative experiences. Individuals with less exposure to the shooting, fewer prior traumatic experiences, and greater satisfaction with social support were more likely to recover from acute distress. Overall, results suggest that, while pretrauma factors may differentiate between those who are resilient in the aftermath of a mass shooting and those who experience heightened distress, several event-level and posttrauma coping factors help distinguish between those who eventually recover and those whose PTSD symptoms persist over time. Copyright © 2014. Published by Elsevier Ltd.

  19. A comparison of CA125, HE4, risk ovarian malignancy algorithm (ROMA, and risk malignancy index (RMI for the classification of ovarian masses

    Directory of Open Access Journals (Sweden)

    Cristina Anton

    2012-01-01

    Full Text Available OBJECTIVE: Differentiation between benign and malignant ovarian neoplasms is essential for creating a system for patient referrals. Therefore, the contributions of the tumor markers CA125 and human epididymis protein 4 (HE4 as well as the risk ovarian malignancy algorithm (ROMA and risk malignancy index (RMI values were considered individually and in combination to evaluate their utility for establishing this type of patient referral system. METHODS: Patients who had been diagnosed with ovarian masses through imaging analyses (n = 128 were assessed for their expression of the tumor markers CA125 and HE4. The ROMA and RMI values were also determined. The sensitivity and specificity of each parameter were calculated using receiver operating characteristic curves according to the area under the curve (AUC for each method. RESULTS: The sensitivities associated with the ability of CA125, HE4, ROMA, or RMI to distinguish between malignant versus benign ovarian masses were 70.4%, 79.6%, 74.1%, and 63%, respectively. Among carcinomas, the sensitivities of CA125, HE4, ROMA (pre-and post-menopausal, and RMI were 93.5%, 87.1%, 80%, 95.2%, and 87.1%, respectively. The most accurate numerical values were obtained with RMI, although the four parameters were shown to be statistically equivalent. CONCLUSION: There were no differences in accuracy between CA125, HE4, ROMA, and RMI for differentiating between types of ovarian masses. RMI had the lowest sensitivity but was the most numerically accurate method. HE4 demonstrated the best overall sensitivity for the evaluation of malignant ovarian tumors and the differential diagnosis of endometriosis. All of the parameters demonstrated increased sensitivity when tumors with low malignancy potential were considered low-risk, which may be used as an acceptable assessment method for referring patients to reference centers.

  20. Targeted mass media interventions promoting healthy behaviours to reduce risk of non-communicable diseases in adult, ethnic minorities.

    Science.gov (United States)

    Mosdøl, Annhild; Lidal, Ingeborg B; Straumann, Gyri H; Vist, Gunn E

    2017-02-17

    Physical activity, a balanced diet, avoidance of tobacco exposure, and limited alcohol consumption may reduce morbidity and mortality from non-communicable diseases (NCDs). Mass media interventions are commonly used to encourage healthier behaviours in population groups. It is unclear whether targeted mass media interventions for ethnic minority groups are more or less effective in changing behaviours than those developed for the general population. To determine the effects of mass media interventions targeting adult ethnic minorities with messages about physical activity, dietary patterns, tobacco use or alcohol consumption to reduce the risk of NCDs. We searched CENTRAL, MEDLINE, Embase, PsycINFO, CINAHL, ERIC, SweMed+, and ISI Web of Science until August 2016. We also searched for grey literature in OpenGrey, Grey Literature Report, Eldis, and two relevant websites until October 2016. The searches were not restricted by language. We searched for individual and cluster-randomised controlled trials, controlled before-and-after studies (CBA) and interrupted time series studies (ITS). Relevant interventions promoted healthier behaviours related to physical activity, dietary patterns, tobacco use or alcohol consumption; were disseminated via mass media channels; and targeted ethnic minority groups. The population of interest comprised adults (≥ 18 years) from ethnic minority groups in the focal countries. Primary outcomes included indicators of behavioural change, self-reported behavioural change and knowledge and attitudes towards change. Secondary outcomes were the use of health promotion services and costs related to the project. Two authors independently reviewed the references to identify studies for inclusion. We extracted data and assessed the risk of bias in all included studies. We did not pool the results due to heterogeneity in comparisons made, outcomes, and study designs. We describe the results narratively and present them in 'Summary of findings

  1. Antibiotics in riverine runoff of the Pearl River Delta and Pearl River Estuary, China: Concentrations, mass loading and ecological risks

    International Nuclear Information System (INIS)

    Xu, Weihai; Yan, Wen; Li, Xiangdong; Zou, Yongde; Chen, Xiaoxiang; Huang, Weixia; Miao, Li; Zhang, Ruijie; Zhang, Gan; Zou, Shichun

    2013-01-01

    Ten antibiotics belonging to three groups (macrolides, fluoroquinolones and sulfonamides) were investigated in riverine runoff of the Pearl River Delta (PRD) and Pearl River Estuary (PRE), South China for assessing the importance of riverine runoff in the transportation of contaminants from terrestrial sources to the open ocean. All antibiotics were detected in the eight outlets with concentrations ranging from 0.7 to 127 ng L −1 . The annual mass loadings of antibiotics from the PRD to the PRE and coast were 193 tons with 102 tons from the fluoroquinolone group. It showed that antibiotics decreased from the riverine outlets to the PRE and open ocean. Risk assessment showed that most of these antibiotics showed various ecological risks to the relevant aquatic organisms, in which ofloxacin (OFL), erythromycin (ETM) and ciprofloxacin (CIP) posed high ecological risks to the studied aquatic environments. -- Highlights: •Antibiotics were ubiquitous in the river water and costal water in the Pearl River Delta. •Antibiotics exhibited distinct temporal and spatial trends in the riverine runoff outlets. •Annual outflows of antibiotics were 193 tons from the Pearl River to coastal ocean. •Some antibiotics posed high risks to some organisms in the PRD environments. -- Antibiotics were ubiquitous in the river and coastal water in the Pearl River Delta and posed various ecological risks to the relevant aquatic organisms

  2. Body Mass Index and Risk of Gallbladder Cancer: Systematic Review and Meta-Analysis of Observational Studies

    Directory of Open Access Journals (Sweden)

    Wenbin Tan

    2015-09-01

    Full Text Available OBJECTIVES: To provide a quantitative assessment of the association between excess body weight, interpreted as increased body mass index (BMI, and the risk of gallbladder cancer (GBC. METHODS: We identified eligible studies in Medline and EMBASE up to 1 February 2015, and reference lists of retrieved articles. Summary relative risks with their 95% confidence intervals were calculated in a random-effects model. Subgroup analyses were performed according to study design, gender, geographic location, ascertainment of exposure and adjustment for confounders. RESUITS: A total of 12 cohort studies and 8 case-control studies were included in the meta-analysis. Overall, compared with “normal” weight, the summary relative risks of GBC were 1.14 (95% CI, 1.04–1.25 for overweight individuals (BMI 25–30 kg/m2 and 1.56 (95% CI, 1.41–1.73 for obese individuals (BMI > 30 kg/m2. Obese women had a higher risk of GBC than men did (women: SRRs 1.67, 95% CI 1.38–2.02; men: SRRs 1.42, 95% CI 1.21–1.66, and there was significant association between overweight and GBC risk in women (SRRs 1.26, 95% CI 1.13–1.40, but not in men (SRRs 1.06, 95% CI 0.94–1.20. CONCLUSIONS: Findings from this meta-analysis indicate that obesity is associated with an increased risk of GBC, especially in women. Overweight is associated with GBC risk only in women.

  3. Use of mass and toxicity balances in risk-based corrective action decisions at contaminated sites

    International Nuclear Information System (INIS)

    Sevigny, J.H.; Lintott, D.; Wrubleski, R.M.; Drury, C.R.

    1997-01-01

    The contaminated groundwater at a sour gas plant facility was studied to identify the chemicals of environmental concern. Simple mass balance principles were used to determine the proportion of organic carbon, organic nitrogen and Microtox R toxicity that can be attributed to two process chemicals that have contaminated several sour gas plants in western Canada. The two process chemicals are sulfolane and diisopropanolamine (DIPA). The organic carbon balance was calculated by determining the molar contribution of sulfolane and DIPA relative to the mass of carboxylic acid-corrected dissolved organic carbon. Organic carbon balances ranged from 44 to 96 per cent. The organic nitrogen balance was calculated by determining the molar contribution of DIPA relative to the mass of ammonium ion-corrected dissolved Kjeldahl nitrogen. The nitrogen balances were highly variable between 8 to 48 per cent for samples with organic nitrogen concentrations between 10 and 32 mg/L. The Microtox R toxicity balance was calculated by determining the proportions of toxicity that could be accounted for by pure phase sulfolane and DIPA. The Microtox R toxicity balance for samples that showed significant toxicity ranged from 71 to 122 per cent

  4. Use of mass and toxicity balances in risk-based corrective action decisions at contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Sevigny, J.H. [Komex Consultants Ltd., Calgary, AB (Canada); Lintott, D. [HydroQual Consultants, Inc., Calgary, AB (Canada); Wrubleski, R.M.; Drury, C.R. [Shell Canada Ltd., Calgary, AB (Canada). Calgary Research Centre

    1997-12-31

    The contaminated groundwater at a sour gas plant facility was studied to identify the chemicals of environmental concern. Simple mass balance principles were used to determine the proportion of organic carbon, organic nitrogen and Microtox{sup R} toxicity that can be attributed to two process chemicals that have contaminated several sour gas plants in western Canada. The two process chemicals are sulfolane and diisopropanolamine (DIPA). The organic carbon balance was calculated by determining the molar contribution of sulfolane and DIPA relative to the mass of carboxylic acid-corrected dissolved organic carbon. Organic carbon balances ranged from 44 to 96 per cent. The organic nitrogen balance was calculated by determining the molar contribution of DIPA relative to the mass of ammonium ion-corrected dissolved Kjeldahl nitrogen. The nitrogen balances were highly variable between 8 to 48 per cent for samples with organic nitrogen concentrations between 10 and 32 mg/L. The Microtox{sup R} toxicity balance was calculated by determining the proportions of toxicity that could be accounted for by pure phase sulfolane and DIPA. The Microtox{sup R} toxicity balance for samples that showed significant toxicity ranged from 71 to 122 per cent.

  5. Body mass index in childhood and adult risk of primary liver cancer

    DEFF Research Database (Denmark)

    Berentzen, Tina Landsvig; Gamborg, Michael; Holst, Claus

    2014-01-01

    BACKGROUND & AIMS: Childhood overweight increases the risk of early development of non-alcoholic fatty liver disease, which may predispose to carcinogenesis. We investigated if childhood body size during school ages was associated with the risk of primary liver cancer in adults. METHODS: A cohort......-specific reference. Information on liver cancer was obtained from the National Cancer Registry. Hazard ratios and 95% confidence intervals (95% CI) of liver cancer were estimated by Cox regression. RESULTS: During 6,963,105 person-years of follow-up, 438 cases of primary liver cancer were recorded. The hazard ratio...... hepatitis, alcohol-related disorders, and biliary cirrhosis. CONCLUSIONS: Higher BMI in childhood increases the risk of primary liver cancer in adults. In view of the high case fatality of primary liver cancer, this result adds to the future negative health outcomes of the epidemic of childhood overweight...

  6. Trajectories of body mass index among Canadian seniors and associated mortality risk.

    Science.gov (United States)

    Wang, Meng; Yi, Yanqing; Roebothan, Barbara; Colbourne, Jennifer; Maddalena, Victor; Sun, Guang; Wang, Peizhong Peter

    2017-12-04

    This study aims to characterize the heterogeneity in BMI trajectories and evaluate how different BMI trajectories predict mortality risk in Canadian seniors. Data came from the Canadian National Population Health Survey (NPHS, 1994-2011) and 1480 individuals aged 65-79 years with at least four BMI records were included in this study. Group-based trajectory model was used to identify distinct subgroups of longitudinal trajectories of BMI measured over 19 years for men and women. Cox proportional hazards models were used to examine the association between BMI trajectories and mortality risks. Distinct trajectory patterns were found for men and women: 'Normal Weight-Down'(N-D), 'Overweight-Normal weight' (OV-N), 'Obese I-Down' (OB I-D), and 'Obese II- Down' (OB II-D) for women; and 'Normal Weight-Down' (N-D), 'Overweight-Normal weight' (OV-N), 'Overweight-Stable' (OV-S), and 'Obese-Stable' (OB-S) for men. Comparing with OV-N, men in the OV-S group had the lowest mortality risk followed by the N-D (HR = 1.66) and OB-S (HR = 1.98) groups, after adjusting for covariates. Compared with OV-N, women in the OB II-D group with three or more chronic health conditions had higher mortality risk (HR = 1.61); however, women in OB II-D had lower risk (HR = 0.56) if they had less than three conditions. The course of BMI over time in Canadian seniors appears to follow one of four different patterns depending on gender. The findings suggest that men who were overweight at age 65 and lost weight over time had the lowest mortality risk. Interestingly, obese women with decreasing BMI have different mortality risks, depending on their chronic health conditions. The findings provide new insights concerning the associations between BMI and mortality risk.

  7. Endocannabinoid receptor 1 gene variations increase risk for obesity and modulate body mass index in European populations

    DEFF Research Database (Denmark)

    Benzinou, Michael; Chèvre, Jean-Claude; Ward, Kirsten J

    2008-01-01

    The therapeutic effects of cannabinoid receptor blockade on obesity-associated phenotypes underline the importance of the endocannabinoid pathway on the energy balance. Using a staged-approach, we examined the contribution of the endocannabinoid receptor 1 gene (CNR1) on obesity and body mass ind...... variations increase the risk for obesity and modulate BMI in our European population. As CB1 is a drug target for obesity, a pharmacogenetic analysis of the endocannabinoid blockade obesity treatment may be of interest to identify best responders....

  8. Height, waist circumference, body mass index, and body somatotype across the life course and risk of glioma.

    Science.gov (United States)

    Cote, David J; Downer, Mary K; Smith, Timothy R; Smith-Warner, Stephanie A; Egan, Kathleen M; Stampfer, Meir J

    2018-06-26

    Recent studies have suggested height as a risk factor for glioma, but less is known regarding body mass index (BMI) or other anthropomorphic measures. We evaluated the association between body habitus and risk of glioma. We evaluated the association of measures of height, BMI, waist circumference, and somatotypes with risk of glioma in two prospective cohorts, the Nurses' Health Study and the Health Professionals Follow-Up Study. We documented 508 incident cases of glioma (321 glioblastoma [GBM]). In both cohorts, we found no significant association between adult BMI or waist circumference and risk of glioma, with pooled HR for BMI of 1.08 (95% CI 0.85-1.38 comparing ≥ 30 to < 25 kg/m 2 ) and for waist circumference of 1.05 (95% CI 0.80-1.37 highest vs. lowest quintile). Higher young adult BMI (at age 18 in NHS and 21 in HPFS) was associated with modestly increased risk of glioma in the pooled cohorts (pooled HR 1.35, 95% CI 1.06-1.72 comparing ≥ 25 kg/m 2 vs. less; HR 1.34 for women and 1.37 for men). Analysis of body somatotypes suggested reduced risk of glioma among women with heavier body types at all ages this measure was assessed (HRs ranging from 0.52 to 0.65 comparing highest tertile to lowest tertile), but no significant association among men. Height was associated with increased risk of glioma among women (HR 1.09, 95% CI 1.04-1.14 per inch), but not significantly among men. Within the 8 years prior to diagnosis, cases had no material weight loss compared to non-cases. All results were similar when limited to GBM. Adult BMI and waist circumference were not associated with glioma. Higher BMI at age 21 for men and at age 18 for women was modestly associated with risk in the pooled cohort. Based on body somatotypes, however, women with heavier body types during childhood and young adulthood may be at lower risk of glioma, although this association was not observed later in life with measurements of BMI. Greater height was associated with

  9. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment—A review

    International Nuclear Information System (INIS)

    Verlicchi, P.; Al Aukidy, M.; Zambello, E.

    2012-01-01

    This review focuses on 118 pharmaceuticals, belonging to seventeen different therapeutic classes, detected in raw urban wastewater and effluent from an activated sludge system, a usual treatment adopted for urban wastewaters worldwide prior to final discharge into surface water bodies. Data pertaining to 244 conventional activated sludge systems and 20 membrane biological reactors are analysed and the observed ranges of variability of each selected compound in their influent and effluent reported, with particular reference to the substances detected most frequently and in higher concentrations. A snapshot of the ability of these systems to remove such compounds is provided by comparing their global removal efficiencies for each substance. Where possible, the study then evaluates the average daily mass load of the majority of detected pharmaceuticals exiting the secondary treatment step. The final part of the review provides an assessment of the environmental risk posed by their presence in the secondary effluent by means of the risk quotient that is the ratio between the average pharmaceutical concentration measured in the secondary effluent and the predicted no-effect concentration. Finally, mass load rankings of the compounds under review are compared with those based on their risk level. This analysis shows that the highest amounts discharged through secondary effluent pertain to one antihypertensive, and several beta-blockers and analgesics/anti-inflammatories, while the highest risk is posed by antibiotics and several psychiatric drugs and analgesics/anti-inflammatories. These results are reported with a view to aiding scientists and administrators in planning measures aiming to reduce the impact of treated urban wastewater discharge into surface water bodies. - Highlights: ► The review refers to 118 pharmaceuticals occurring in raw and treated wastewaters. ► Data from 264 municipal WWTPs with a CAS or an MBR were analysed. ► The removal rates achieved

  10. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment-A review

    Energy Technology Data Exchange (ETDEWEB)

    Verlicchi, P., E-mail: paola.verlicchi@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Terra and AcquaTech Technopoles, Via Borsari 46, I-44121 Ferrara (Italy); Al Aukidy, M., E-mail: mustafakether.alaukidi@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Zambello, E., E-mail: elena.zambello@unife.it [Dept. of Engineering, University of Ferrara, Via Saragat 1, I-44122 Ferrara (Italy); Terra and AcquaTech Technopoles, Via Borsari 46, I-44121 Ferrara (Italy)

    2012-07-01

    This review focuses on 118 pharmaceuticals, belonging to seventeen different therapeutic classes, detected in raw urban wastewater and effluent from an activated sludge system, a usual treatment adopted for urban wastewaters worldwide prior to final discharge into surface water bodies. Data pertaining to 244 conventional activated sludge systems and 20 membrane biological reactors are analysed and the observed ranges of variability of each selected compound in their influent and effluent reported, with particular reference to the substances detected most frequently and in higher concentrations. A snapshot of the ability of these systems to remove such compounds is provided by comparing their global removal efficiencies for each substance. Where possible, the study then evaluates the average daily mass load of the majority of detected pharmaceuticals exiting the secondary treatment step. The final part of the review provides an assessment of the environmental risk posed by their presence in the secondary effluent by means of the risk quotient that is the ratio between the average pharmaceutical concentration measured in the secondary effluent and the predicted no-effect concentration. Finally, mass load rankings of the compounds under review are compared with those based on their risk level. This analysis shows that the highest amounts discharged through secondary effluent pertain to one antihypertensive, and several beta-blockers and analgesics/anti-inflammatories, while the highest risk is posed by antibiotics and several psychiatric drugs and analgesics/anti-inflammatories. These results are reported with a view to aiding scientists and administrators in planning measures aiming to reduce the impact of treated urban wastewater discharge into surface water bodies. - Highlights: Black-Right-Pointing-Pointer The review refers to 118 pharmaceuticals occurring in raw and treated wastewaters. Black-Right-Pointing-Pointer Data from 264 municipal WWTPs with a CAS or an

  11. Maternal body mass index before pregnancy as a risk factor for ADHD and autism in children.

    Science.gov (United States)

    Andersen, Christina Hebsgaard; Thomsen, Per Hove; Nohr, Ellen Aagaard; Lemcke, Sanne

    2018-02-01

    The risk of attention-deficit/hyperactivity disorder (ADHD) and autism spectrum disorders (ASD) may be influenced by environmental factors such as maternal obesity before pregnancy. Previous studies investigating those associations have found divergent results. We aim to investigate in a large birth cohort this association further in children with ADHD, ASD and comorbid ADHD and ASD. Our study population consisted of 81,892 mother-child pairs participating in the Danish National Birth Cohort (DNBC). Information about pre-pregnancy weight and height was collected in week 16 of pregnancy; the analysis was divided into groups based on BMI. Children with a clinical diagnosis of ADHD and/or ASD were identified in the Danish health registries at an average age of 13.3 years. Hazard ratios (HRs) were estimated using time-to-event analysis. Compared to normal weight mothers, the risk of having a child with ADHD was significantly increased if the mother was overweight (HR = 1.28 [95% CI 1.15;1.48]), obese (HR = 1.47 [95% CI 1.26;1.71]) or severely obese (HR = 1.95 [95% CI 1.58;2.40]). The same pattern was seen for the combined ADHD and ASD group. Regarding ASD, an increased risk was observed in underweight (HR = 1.30 [95% CI 1.01;1.69]) and obese (HR = 1.39 [95% CI 1.11;1.75]) mothers. Subgroup analysis revealed that the association in the ADHD group could mostly be attributable to the hyperactive group. Maternal obesity before pregnancy is a risk factor for ADHD in children. Maternal obesity as well as underweight may also be associated with an increased risk for ASD.

  12. Submarine mass wasting and associated tsunami risk offshore western Thailand, Andaman Sea, Indian Ocean

    Directory of Open Access Journals (Sweden)

    J. M. Schwab

    2012-08-01

    Full Text Available 2-D seismic data from the top and the western slope of Mergui Ridge in water depths between 300 and 2200 m off the Thai west coast have been investigated in order to identify mass transport deposits (MTDs and evaluate the tsunamigenic potential of submarine landslides in this outer shelf area. Based on our newly collected data, 17 mass transport deposits have been identified. Minimum volumes of individual MTDs range between 0.3 km3 and 14 km3. Landslide deposits have been identified in three different settings: (i stacked MTDs within disturbed and faulted basin sediments at the transition of the East Andaman Basin to the Mergui Ridge; (ii MTDs within a pile of drift sediments at the basin-ridge transition; and (iii MTDs near the edge of/on top of Mergui Ridge in relatively shallow water depths (< 1000 m. Our data indicate that the Mergui Ridge slope area seems to have been generally unstable with repeated occurrence of slide events. We find that the most likely causes for slope instabilities may be the presence of unstable drift sediments, excess pore pressure, and active tectonics. Most MTDs are located in large water depths (> 1000 m and/or comprise small volumes suggesting a small tsunami potential. Moreover, the recurrence rates of failure events seem to be low. Some MTDs with tsunami potential, however, have been identified on top of Mergui Ridge. Mass-wasting events that may occur in the future at similar locations may trigger tsunamis if they comprise sufficient volumes. Landslide tsunamis, emerging from slope failures in the working area and affecting western Thailand coastal areas therefore cannot be excluded, though the probability is very small compared to the probability of earthquake-triggered tsunamis, arising from the Sunda Trench.

  13. Body Mass Index and Risk of Infections Among Women in the Danish National Birth Cohort

    DEFF Research Database (Denmark)

    Harpsøe, Maria C; Nielsen, Nete M; Friis-Møller, Nina

    2016-01-01

    baseline BMI and later hospitalization for 1) any infectious disease and 2) infections of the respiratory tract, whereas a dose-response relationship was seen for skin infections. The most pronounced associations were seen for acute upper respiratory infections at multiple and unspecified sites...... was observed among overweight (BMI 25-infections of the upper respiratory tract and skin.......We investigated the possible association between body mass index (BMI; weight (kg)/height (m)(2)) and hospitalization or treatment for acute infection in a prospective cohort study. We linked 75,001 women enrolled in the Danish National Birth Cohort from 1996 to 2002, who had information on BMI...

  14. Occupational coke oven emissions exposure and risk of abnormal liver function: modifications of body mass index and hepatitis virus infection

    Energy Technology Data Exchange (ETDEWEB)

    Y. Hu; B. Chen; J. Qian; L. Jin; T. Jin; D. Lu [Fudan University, Shanghai (China). Department of Occupational and Environmental Health

    2010-03-15

    Occupational coke oven emissions (COEs) have been considered an important health issue. However, there are no conclusive data on human hepatic injury due to COE exposure. The association of COE exposure with liver function was explored and the effects of modification of potential non-occupational factors were assessed. 705 coke oven workers and 247 referents were investigated. Individual cumulative COE exposure was quantitatively estimated. Serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), {gamma}-glutamyl transferase, alkaline phosphatase, hepatitis B surface antigen and anti-hepatitis C antibody were measured. Among those with high COE exposure, the adjusted ORs of abnormal ALT and AST were 5.23 (95% CI 2.66 to 10.27) and 1.95 (95% CI 1.18 to 3.52), respectively. Overweight individuals (body mass index (BMI) {>=}25 kg/m{sup 2}) with high COE exposure had elevated risks of abnormal ALT (adjusted OR 23.93, 95% CI 8.73 to 65.62) and AST (adjusted OR 5.18, 95% CI 2.32 to 11.58). Risk of liver damage in hepatitis B virus- or hepatitis C virus-positive individuals with COE exposure was also elevated. Long-term exposure to COE increases the risk of liver dysfunction, which is more prominent among those with higher BMI and hepatitis virus infection. The risk assessment of liver damage associated with COE exposure should take BMI and hepatitis virus infection into consideration.

  15. Associations of Body Mass Index with Sexual Risk-Taking and Injection Drug Use among US High School Students

    Directory of Open Access Journals (Sweden)

    Richard Lowry

    2014-01-01

    Full Text Available The purpose of this study was to determine if body mass index (BMI is associated with behaviors that may increase risk for HIV and other sexually transmitted diseases (STDs among US high school students. We analyzed nationally representative data from the 2005–2011 national Youth Risk Behavior Surveys (YRBS to examine associations of BMI categories with sexual risk behaviors and injection drug use among sexually active high school students, using sex-stratified logistic regression models. Controlling for race/ethnicity and grade, among female and male students, both underweight (BMI < 5th percentile and obesity (BMI ≥ 95th percentile were associated with decreased odds of being currently sexually active (i.e., having had sexual intercourse during the past 3 months. However, among sexually active female students, obese females were more likely than normal weight females to have had 4 or more sex partners (odds ratio, OR = 1.59, not used a condom at last sexual intercourse (OR = 1.30, and injected illegal drugs (OR = 1.98. Among sexually active male students, overweight (85th percentile ≤ BMI < 95th percentile was associated with not using a condom at last sexual intercourse (OR = 1.19 and obesity was associated with injection drug use (OR = 1.42. Among sexually active students, overweight and obesity may be indicators of increased risk for HIV and other STDs.

  16. Body mass index, waist circumference, type 2 diabetes mellitus and risk of liver cancer for U.S. adults

    Science.gov (United States)

    Campbell, Peter T.; Newton, Christina C.; Freedman, Neal D.; Koshiol, Jill; Alavanja, Michael C.; Beane Freeman, Laura E.; Buring, Julie E.; Chan, Andrew T.; Chong, Dawn Q.; Datta, Mridul; Gaudet, Mia M.; Gaziano, J. Michael; Giovannucci, Edward; Graubard, Barry; Hollenbeck, Albert R.; King, Lindsey; Lee, I-Min; Linet, Martha; Palmer, Julie; Petrick, Jessica L.; Poynter, Jenny N.; Purdue, Mark; Robien, Kim; Rosenberg, Lynn; Sahasrabuddhe, Vikrant; Schairer, Catherine; Sesso, Howard D.; Sigurdson, Alice; Stevens, Victoria L.; Wactowski-Wende, Jean; Zeleniuch-Jacquotte, Anne; Renehan, Andrew G.; McGlynn, Katherine A.

    2016-01-01

    Incidence rates for liver cancer have increased threefold since the mid-1970s in the United States in parallel with increasing trends for obesity and type 2 diabetes mellitus (T2DM). We conducted an analysis of baseline body mass index (BMI), waist circumference (WC), and T2DM with risk of liver cancer. The Liver Cancer Pooling Project maintains harmonized data from 1.57 million adults enrolled in 14 U.S.-based prospective studies. Cox regression estimated hazard ratios (HR) and 95% confidence intervals (CI) adjusted for age, sex, study center, alcohol, smoking, race, and BMI (for WC and T2DM). Stratified analyses assessed whether the BMI-liver cancer associations differed by hepatitis sera-positivity in nested analyses for a subset of cases (n=220) and controls (n=547). After enrollment, 2,162 incident liver cancer diagnoses were identified. BMI, per 5 kg/m2, was associated with higher risks of liver cancer, more so for men (HR: 1.38; 95% CI: 1.30 to 1.46) than women (HR: 1.25; 95% CI: 1.17 to 1.35; p-interaction: 0.02). WC, per 5 cm, was associated with higher risks of liver cancer, approximately equally by sex (overall, HR: 1.08; 95% CI: 1.04 to 1.13). T2DM was associated with higher risk of liver cancer (HR: 2.61; 95% CI: 2.34 to 2.91). In stratified analyses, there was a null association between BMI and liver cancer risk for participants who were sera-positive for hepatitis. This study suggests that high BMI, high WC, and T2DM are associated with higher risks of liver cancer and that the association may differ by status of viral hepatitis infection. PMID:27742674

  17. Reduced risk of Parkinson's disease associated with lower body mass index and heavy leisure-time physical activity.

    Science.gov (United States)

    Sääksjärvi, Katri; Knekt, Paul; Männistö, Satu; Lyytinen, Jukka; Jääskeläinen, Tuija; Kanerva, Noora; Heliövaara, Markku

    2014-04-01

    The risk factors for Parkinson's disease (PD) are not well established. We therefore examined the prediction of various lifestyle factors on the incidence of PD in a cohort drawn from the Finnish Mobile Clinic Health Examination Survey, conducted in 1973-1976. The study population comprised 6,715 men and women aged 50-79 years and free of PD at the baseline. All of the subjects completed a baseline health examination (including height and weight measurements) and a questionnaire providing information on leisure-time physical activity, smoking, and alcohol consumption. During a 22-year follow-up, 101 incident cases of PD occurred. The statistical analyses were based on Cox's model including age, sex, education, community density, occupation, coffee consumption, body mass index (BMI), leisure-time physical activity, smoking and alcohol consumption as independent variables. At first, BMI was not associated with PD risk, but after exclusion of the first 15 years of follow-up, an elevated risk appeared at higher BMI levels (P for trend 0.02). Furthermore, subjects with heavy leisure-time physical activity had a lower PD risk than those with no activity [relative risk (RR) 0.27, 95 % confidence interval (CI) 0.08-0.90]. In variance with findings for other chronic diseases, current smokers had a lower PD risk than those who had never smoked (RR 0.23, 95 % CI 0.08-0.67), and individuals with moderate alcohol intake (at the level of Parkinson's disease, but more research is needed.

  18. Limb/trunk lean mass ratio as a risk factor for mortality in peritoneal dialysis patients.

    Science.gov (United States)

    Kang, Seok Hui; Park, Jong Won; Yoon, Kyung Woo; Do, Jun Young

    2013-07-01

    This study was performed to determine the clinical relevance of limb/trunk lean mass ratio (LTLM) in continuous ambulatory peritoneal dialysis (CAPD) patients. This retrospective cohort study included 534 CAPD patients. Body compositions were measured using a dual-energy X-ray absorptiometry apparatus. In males, the sensitivity and specificity for the diagnosis of sarcopenia were 70.3% and 85.9%, respectively. Respective values in females were 62.3% and 83.8%. The initial low LTLM tertile was associated with mortality in male CAPD patients and in female CAPD patients. Among patients who maintained CAPD for a year, the maintenance of low LTLM tertile was associated with mortality. LTLM is associated with other lean mass indices, nutritional status, and mortality in CAPD patients. Therefore, LTLM is a novel marker that is useful for the prediction of the nutritional status and mortality in patients with CAPD. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  19. Maternal body mass index before pregnancy as a risk factor for ADHD and autism in children

    DEFF Research Database (Denmark)

    Andersen, Christina Hebsgaard; Thomsen, Per Hove; Nohr, Ellen Aagaard

    2018-01-01

    The risk of attention-deficit/hyperactivity disorder (ADHD) and autism spectrum disorders (ASD) may be influenced by environmental factors such as maternal obesity before pregnancy. Previous studies investigating those associations have found divergent results. We aim to investigate in a large...... birth cohort this association further in children with ADHD, ASD and comorbid ADHD and ASD. Our study population consisted of 81,892 mother-child pairs participating in the Danish National Birth Cohort (DNBC). Information about pre-pregnancy weight and height was collected in week 16 of pregnancy......; the analysis was divided into groups based on BMI. Children with a clinical diagnosis of ADHD and/or ASD were identified in the Danish health registries at an average age of 13.3 years. Hazard ratios (HRs) were estimated using time-to-event analysis. Compared to normal weight mothers, the risk of having...

  20. Height, weight and body mass index in early adulthood and risk of schizophrenia

    DEFF Research Database (Denmark)

    Sørensen, Holger Jelling; Mortensen, E L; Reinisch, J M

    2006-01-01

    individuals born between 1959 and 1961. In 1999, cases of schizophrenia were identified in the Danish Psychiatric Central Register, and the cases were compared with the cohort pool of controls with respect to height, weight, and BMI from draft records. The effect of low BMI was adjusted for parental social...... status when the cohort members were 1 year old, birth weight, birth length, and maternal pre-pregnancy BMI. RESULTS: Forty-five cases of schizophrenia had a lower young adult mean body weight and BMI than controls. A significant inverse relationship between BMI and risk of later schizophrenia was found....... No significant differences between cases and controls were observed with respect to adult height. CONCLUSION: Independent of several possible confounders, an inverse relationship between young adult BMI and risk of later development of schizophrenia was demonstrated in this all-male sample....

  1. Categorizing Weapons of Mass Destruction Biological Agents into Postmortem Risk Groups

    Science.gov (United States)

    2012-12-20

    43. Krishan, Vij, & Krishan, Kewal. Risk Factors And Prevention Of Infection In Autopsy Room - A Review. Indian Internet Journal Of Forensic ...June 2002. 99. U.S. Army Center for Health Promotion and Preventive Medicine, Entomological Sciences Program, Tularemia Just the Facts, Pages 1-2...The American Journal of Forensic Medicine and Pathology, 23(2):107–122, 2002. 138. US Army Medical Research Institute of Infectious Diseases

  2. [Risk groups in travel to tropical countries within the frame of mass tourism].

    Science.gov (United States)

    van der Linde, F; Steffen, R; Schwarzenbach, F H

    1977-01-01

    More than 10,000 tourists returning from tropical countries have been asked about health problems during their stay abroad. Preliminary results from the first 5,550 questionnaires indicate that 74,8% had complaints of any kind concerning their health and 13,6% can be considered as having been ill. The frequency of complaints and illness in relation to different variables is shown and the possibility of definition of high risk groups is being discussed.

  3. Body Mass Index below Obesity Threshold Implies Similar Cardiovascular Risk among Various Polycystic Ovary Syndrome Phenotypes.

    Science.gov (United States)

    Bagir, Gulay Simsek; Bakiner, Okan S; Bozkirli, Emre; Cavlak, Gulhan; Serinsoz, Hulya; Ertorer, M Eda

    2016-01-01

    The aim of this study was to determine the cardiometabolic risk factors in different polycystic ovary syndrome (PCOS) phenotypes. This cross-sectional study was performed between 2010 and 2011. Eighty-nine patients with PCOS and 25 age- and weight-matched healthy controls were included in the study. Patients were grouped using the Rotterdam 2003 criteria as: group 1, oligomenorrhea and/or anovulation (ANOV) and hyperandrogenemia (HA) and/or hyperandrogenism (n = 23); group 2, ANOV and polycystic ovaries (PCO; n = 22); group 3, HA and PCO (n = 22); group 4, ANOV, HA and PCO (n = 22); group 5, controls (n = 25). Laboratory blood tests for diagnosis and cardiometabolic risk assessments were performed. Insulin resistance (IR) was calculated in all patients with the homeostasis model assessment of IR (HOMA-IR) formula. An euglycemic hyperinsulinemic clamp test was performed on 5 randomly selected cases in each subgroup, making 25 cases in total, and indicated as the 'M' value (mg/kg/min), which is the total body glucose disposal rate. The mean BMl values of the groups were: group 1, 26.1 ± 5.3; group 2, 27.9 ± 5.2; group 3, 24.3 ± 4.2; group 4, 27.9 ± 7.5; group 5, 24.7 ± 5.2 (p > 0.05). There were no differences in the lipid profile, plasma glucose, HOMA-IR, insulin and M values between the groups (p > 0.05). Phenotypes with oligomenorrhea/anovulation (groups 1, 2 and 4) were more obese than group 3 (p = 0.039). The cardiometabolic risk profile was similar among the PCOS subgroups. This finding could be attributed to the mean BMl values, which, being below 30, were not within the obesity range. Obesity appeared to be an important determinant of high cardiovascular risk in PCOS. © 2015 S. Karger AG, Basel.

  4. Body mass index, cognitive deficit and depressive symptoms in high cardiovascular risk patients

    Directory of Open Access Journals (Sweden)

    Amanda Lucas da Costa

    Full Text Available Abstract To evaluate the relationship of obesity, cognitive impairment and depressive symptoms in patients with high cardiovascular risk. Methods: A sample of 93 patients aged 50 years or older was selected from the Center of Dyslipidemia and High Cardiovascular Risk from Hospital de Clínicas de Porto Alegre (HCPA. Patients with stroke were excluded. For cognitive evaluation, the MMSE (Mini Mental State Examination was used. A score of 24 or less was considered as cognitive impairment, and for those who had 4 years or less of education, the cutoff point was 17. The GDS-15 (Geriatric Depression Scale was also used, with the cutoff of 6 for presence of depressive symptoms. Results: Obese patients showed lower mean MMSE scores compared to non-obese patients (p=0.0012. Additionally, for every one point increase in BMI above 30 there was a 27% increase in the chances of the patient having cognitive impairment. The obese patients presented 31% chance of having cognitive impairment compared with overweight subjects. Conclusions: Our findings corroborated the association between obesity and cognitive impairment in high cardiovascular risk patients. This association however, was not observed for depressive symptoms.

  5. Increasing help-seeking and referrals for individuals at risk for suicide by decreasing stigma: the role of mass media.

    Science.gov (United States)

    Niederkrotenthaler, Thomas; Reidenberg, Daniel J; Till, Benedikt; Gould, Madelyn S

    2014-09-01

    Increasing help-seeking and referrals for at-risk individuals by decreasing stigma has been defined as Aspirational Goal 10 in the National Action Alliance for Suicide Prevention's Research Prioritization Task Force's 2014 prioritized research agenda. This article reviews the research evidence on the impact of mass media awareness campaigns on reducing stigma and increasing help-seeking. The review will focus on both beneficial and iatrogenic effects of suicide preventive interventions using media campaigns to target the broad public. A further focus is on collaboration between public health professionals and news media in order to reduce the risk of copycat behavior and enhance help-seeking behavior. Examples of multilevel approaches that include both mass media interventions and individual-level approaches to reduce stigma and increase referrals are provided as well. Multilevel suicide prevention programs that combine various approaches seem to provide the most promising results, but much more needs to be learned about the best possible composition of these programs. Major research and practice challenges include the identification of optimal ways to reach vulnerable populations who likely do not benefit from current awareness strategies. Caution is needed in all efforts that aim to reduce the stigma of suicidal ideation, mental illness, and mental health treatment in order to avoid iatrogenic effects. The article concludes with specific suggestions for research questions to help move this line of suicide research and practice forward. Copyright © 2014 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  6. [Relationship between the risk of emergency cesarean section for nullipara with the prepregnancy body mass index or gestational weight gain].

    Science.gov (United States)

    Zhao, R F; Zhang, W Y; Zhou, L

    2017-11-25

    Objective: To investigate the risk of emergency cesarean section during labor with the pre-pregnancy body mass index or gestational weight gain. Methods: A total of 6 908 healthy nullipara with singleton pregnancy and cephalic presentation who was in term labor in Beijing Obstetrics and Gynecology Hospital from August 1(st), 2014 to September 30(th), 2015 were recruited. They were divided into two groups, the vaginal delivery group (92.88%, 6 416/6 908) and the emergency cesarean section group (7.12%, 492/6 908). According to WHO body mass index (BMI) classification criteria and the pre-pregnancy BMI, the 6 908 women were divided into three groups, the underweight group(BMIgain (GWG) group (16.72%, 1 155/6 908), the appropriate GWG group (43.11%, 2 978/6 908), the excessive GWG group (40.17%, 2 775/6 908). Unadjusted and adjusted odds ratio ( OR ) and confidence interval ( CI ) of the risk of emergency cesarean section were calculated by bivariate logistic regression. Results: (1) Comparing to the vaginal delivery group, women in the emergency cesarean section group were older, with a lower education level. Their prepregnancy BMI was higer and had more gestational weight gain. They had higher morbidity of pregnancy induced hypertension and gestational diabetes mellitus. Comparing to the vaginal delivery group, the neonates in the emergency cesarean section group were elder in gestational week, with higher birth weight. More male infants and large for gestation age infants were seen in the emergency cesarean section group (all P gain was associated with the increased risk of emergency cesarean section, (a OR= 1.03, 95% CI : 1.01-1.05). GWG above IOM giudelines did not independently affect the risk of emergency cesarean section ( OR= 1.30, 95% CI : 1.07-1.58; a OR= 1.01, 95% CI : 0.82-1.24). In the underweight group, the normal weight group and the overweight or obese group, the excessive GWG women and the appropriate GWG women had no significant difference in the

  7. Managing high-risk patients: the Mass General care management programme

    Directory of Open Access Journals (Sweden)

    Dennis L Kodner

    2015-09-01

    Full Text Available The Massachusetts General Care Management Program (Mass General CMP or CMP was designed as a federally supported demonstration to test the impact of intensive, practice-based care management on high-cost Medicare fee-for-service (FFS beneficiaries—primarily older persons—with multiple hospitalisations and multiple chronic conditions. The Massachusetts General Care Management Program operated over a 6-year period in two phases (3 years each. It started during the first phase at Massachusetts General Hospital, a major academic medical centre in Boston, Massachusetts in collaboration with Massachusetts General Physicians Organisation. During the second phase, the programme expanded to two more affiliated sites in and around the Boston area, including a community hospital, as well as incorporated several modifications primarily focused on the management of transitions to post-acute care in skilled nursing facilities. At the close of the demonstration in July 2012, Mass General Massachusetts General Care Management Program became a component of a new Pioneer accountable care organisation (ACO. The Massachusetts General Care Management Program is focused on individuals meeting defined eligibility criteria who are offered care that is integrated by a case manager embedded in a primary care practice. The demonstration project showed substantial cost savings compared to fee-for-service patients served in the traditional Medicare system but no impact on hospital readmissions. The Massachusetts General Care Management Program does not rest upon a “whole systems” approach to integrated care. It is an excellent example of how an innovative care co-ordination programme can be implemented in an existing health-care organisation without making fundamental changes in its underlying structure or the way in which direct patient care services are paid for. The accountable care organisation version of the Massachusetts General Care Management Program

  8. Eight-Shaped Hatching Increases the Risk of Inner Cell Mass Splitting in Extended Mouse Embryo Culture.

    Directory of Open Access Journals (Sweden)

    Zheng Yan

    Full Text Available Increased risk of monozygotic twinning (MZT has been shown to be associated with assisted reproduction techniques, particularly blastocyst culture. Interestingly, inner cell mass (ICM splitting in human '8'-shaped hatching blastocysts that resulted in MZT was reported. However, the underlying cause of MZT is not known. In this study, we investigated in a mouse model whether in vitro culture leads to ICM splitting and its association with hatching types. Blastocyst hatching was observed in: (i in vivo developed blastocysts and (ii-iii in vitro cultured blastocysts following in vivo or in vitro fertilization. We found that '8'-shaped hatching occurred with significantly higher frequency in the two groups of in vitro cultured blastocysts than in the group of in vivo developed blastocysts (24.4% and 20.4% versus 0.8%, respectively; n = 805, P < 0.01. Moreover, Oct4 immunofluorescence staining was performed to identify the ICM in the hatching and hatched blastocysts. Scattered and split distribution of ICM cells was observed around the small zona opening of '8'-shaped hatching blastocysts. This occurred at a high frequency in the in vitro cultured groups. Furthermore, we found more double OCT4-positive masses, suggestive of increased ICM splitting in '8'-shaped hatching and hatched blastocysts than in 'U'-shaped hatching and hatched blastocysts (12.5% versus 1.9%, respectively; n = 838, P < 0.01. Therefore, our results demonstrate that extended in vitro culture can cause high frequencies of '8'-shaped hatching, and '8'-shaped hatching that may disturb ICM herniation leading to increased risk of ICM splitting in mouse blastocysts. These results may provide insights into the increased risk of human MZT after in vitro fertilization and blastocyst transfer.

  9. Association of waist circumference, body mass index and conicity index with cardiovascular risk factors in postmenopausal women.

    Science.gov (United States)

    Shidfar, Farzad; Alborzi, Fatemeh; Salehi, Maryam; Nojomi, Marzieh

    2012-09-01

    In menopause, changes in body fat distribution lead to increasing risk of cardiovascular disease and metabolic disorders. The aim of this study was to assess the association of adiposity using the conicity index (CI), body mass index (BMI) and waist circumference (WC) with cardiovascular risk factors (hypertension, diabetes and dyslipidaemia). The sample of this cross-sectional study was collected from June to October 2010 and 165 consecutive menopausal women who had attended the Health and Treatment Centre and Endocrine Research Centre of Firoozgar Hospital in Tehran, Iran were assessed. Age, weight, height, WC, waist-hip ratio (WHR), CI and fat mass were measured. Systolic and diastolic blood pressure (SBP and DBP), fasting blood glucose, insulin, low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C) and total cholesterol (TC) levels were also determined. All statistical analyses were performed by SPSS version 17 (SPSS Inc, Chicago, IL, USA). Results showed that BMI was positively and significantly associated with SBP (r = 0.21; p = 0.009). WC was positively and significantly correlated with SBP (r = 0.26; p = 0.02) and DBP (r = 0.16; p = 0.05). WHR was also significantly and positively associated with SBP (r = 0.29; p = 0.001). Age and WC were associated with CI quartiles at the 0.05 significance level. The correlation of CI quartiles with SBP and weight were at the 0.01 significance level. We showed a significant association of WC with SBP and DBP, and that BMI could be an important determining factor of SBP. For assessing the association between CI and cardiovascular risk factors, future studies with larger sample sizes are recommended.

  10. The Role of Age and Excess Body Mass Index in Progression to Type 1 Diabetes in At-Risk Adults.

    Science.gov (United States)

    Ferrara, Christine T; Geyer, Susan M; Evans-Molina, Carmella; Libman, Ingrid M; Becker, Dorothy J; Wentworth, John M; Moran, Antoinette; Gitelman, Stephen E; Redondo, Maria J

    2017-12-01

    Given the global rise in both type 1 diabetes incidence and obesity, the role of body mass index (BMI) on type 1 diabetes pathophysiology has gained great interest. Sustained excess BMI in pediatric participants of the TrialNet Pathway to Prevention (PTP) cohort increased risk for progression to type 1 diabetes, but the effects of age and obesity in adults remain largely unknown. To determine the effect of age and sustained obesity on the risk for type 1 diabetes in adult participants in the TrialNet PTP cohort (i.e., nondiabetic autoantibody-positive relatives of patients with type 1 diabetes). Longitudinally accumulated BMI >25 kg/m2 was calculated to generate a cumulative excess BMI (ceBMI) for each participant, with ceBMI values ≥0 kg/m2 and ≥5 kg/m2 representing sustained overweight or obese status, respectively. Recursive partitioning analysis yielded sex- and age-specific thresholds for ceBMI that confer the greatest risk for type 1 diabetes progression. In this cohort of 665 adults (age 20 to 50 years; median follow-up, 3.9 years), 49 participants developed type 1 diabetes. Age was an independent protective factor for type 1 diabetes progression (hazard ratio, 0.95; P = 0.008), with a threshold of >35 years that reduced risk for type 1 diabetes. In men age >35 years and women age <35 years, sustained obesity (ceBMI ≥5 kg/m2) increased the risk for type 1 diabetes. Age is an important factor for type 1 diabetes progression in adults and influences the impact of elevated BMI, indicating an interplay of excess weight, age, and sex in adult type 1 diabetes pathophysiology. Copyright © 2017 Endocrine Society

  11. The "lipid accumulation product" performs better than the body mass index for recognizing cardiovascular risk: a population-based comparison

    Directory of Open Access Journals (Sweden)

    Kahn Henry S

    2005-09-01

    Full Text Available Abstract Background Body mass index (BMI, kg/m2 may not be the best marker for estimating the risk of obesity-related disease. Consistent with physiologic observations, an alternative index uses waist circumference (WC and fasting triglycerides (TG concentration to describe lipid overaccumulation. Methods The WC (estimated population minimum 65 cm for men and 58 cm for women and TG concentration from the third National Health and Nutrition Examination Survey (N = 9,180, statistically weighted to represent 100.05 million US adults were used to compute a "lipid accumulation product" [LAP = (WC-65 × TG for men and (WC-58 × TG for women] and to describe the population distribution of LAP. LAP and BMI were compared as categorical variables and as log-transformed continuous variables for their ability to identify adverse levels of 11 cardiovascular risk factors. Results Nearly half of the represented population was discordant for their quartile assignments to LAP and BMI. When 23.54 million with ordinal LAP quartile > BMI quartile were compared with 25.36 million with ordinal BMI quartile > LAP quartile (regression models adjusted for race-ethnicity and sex the former had more adverse risk levels than the latter (p 0.1. As continuous variables, LAP provided a consistently more adverse beta coefficient (slope than BMI for nine cardiovascular risk variables (p 0.2. Conclusion LAP (describing lipid overaccumulation performed better than BMI (describing weight overaccumulation for identifying US adults at cardiovascular risk. Compared to BMI, LAP might better predict the incidence of cardiovascular disease, but this hypothesis needs prospective testing.

  12. Urbanization of black South African women may increase risk of low bone mass due to low vitamin D status, low calcium intake and high bone turnover

    OpenAIRE

    Kruger, Annamarie; Kruger, Marlena C.; Kruger, Iolanthé Marike; Wentzel-Viljoen, Edelweiss

    2011-01-01

    Globally, rural to urban migration is accompanied by changes in dietary patterns and lifestyle that have serious health implications, including development of low bone mass. We hypothesized that serum 25 (OH) vitamin D3 (25[OH]D3) levels will be lower, bone turnover higher, and nutrition inadequate in urban postmenopausal black women, increasing risk for low bone mass. We aimed to assess the prevalence of risk factors for low bone mass in 1261 black women from rural and urban areas in the Nor...

  13. Genetically Predicted Body Mass Index and Breast Cancer Risk : Mendelian Randomization Analyses of Data from 145,000 Women of European Descent

    NARCIS (Netherlands)

    Guo, Yan; Warren Andersen, Shaneda; Shu, Xiao-Ou; Michailidou, Kyriaki; Bolla, Manjeet K; Wang, Qin; Garcia-Closas, Montserrat; Milne, Roger L; Schmidt, Marjanka K; Chang-Claude, Jenny; Dunning, Allison; Bojesen, Stig E; Ahsan, Habibul; Aittomäki, Kristiina; Andrulis, Irene L; Anton-Culver, Hoda; Arndt, Volker; Beckmann, Matthias W; Beeghly-Fadiel, Alicia; Benitez, Javier; Bogdanova, Natalia V; Bonanni, Bernardo; Børresen-Dale, Anne-Lise; Brand, Judith; Brauch, Hiltrud; Brenner, Hermann; Brüning, Thomas; Burwinkel, Barbara; Casey, Graham; Chenevix-Trench, Georgia; Couch, Fergus J; Cox, Angela; Cross, Simon S; Czene, Kamila; Devilee, Peter; Dörk, Thilo; Dumont, Martine; Fasching, Peter A; Figueroa, Jonine; Flesch-Janys, Dieter; Fletcher, Olivia; Flyger, Henrik; Fostira, Florentia; Gammon, Marilie; Giles, Graham G; Guénel, Pascal; Haiman, Christopher A; Hamann, Ute; Hooning, Maartje J; Hopper, John L; Jakubowska, Anna; Jasmine, Farzana; Jenkins, Mark; John, Esther M; Johnson, Nichola; Jones, Michael E; Kabisch, Maria; Kibriya, Muhammad; Knight, Julia A; Koppert, Linetta B; Kosma, Veli-Matti; Kristensen, Vessela; Le Marchand, Loic; Lee, Eunjung; Li, Jingmei; Lindblom, Annika; Luben, Robert; Lubinski, Jan; Malone, Kathi E; Mannermaa, Arto; Margolin, Sara; Marme, Frederik; McLean, Catriona; Meijers-Heijboer, Hanne; Meindl, Alfons; Neuhausen, Susan L; Nevanlinna, Heli; Neven, Patrick; Olson, Janet E; Perez, Jose I A; Perkins, Barbara; Peterlongo, Paolo; Phillips, Kelly-Anne; Pylkäs, Katri; Rudolph, Anja; Santella, Regina; Sawyer, Elinor J; Schmutzler, Rita K; Seynaeve, Caroline; Shah, Mitul; Shrubsole, Martha J; Southey, Melissa C; Swerdlow, Anthony J; Toland, Amanda E; Tomlinson, Ian; Torres, Diana; Truong, Thérèse; Ursin, Giske; Van Der Luijt, Rob B; Verhoef, Senno; Whittemore, Alice S; Winqvist, Robert; Zhao, Hui; Zhao, Shilin; Hall, Per; Simard, Jacques; Kraft, Peter; Pharoah, Paul; Hunter, David; Easton, Douglas F; Zheng, Wei

    BACKGROUND: Observational epidemiological studies have shown that high body mass index (BMI) is associated with a reduced risk of breast cancer in premenopausal women but an increased risk in postmenopausal women. It is unclear whether this association is mediated through shared genetic or

  14. Effects of a general practice-based intervention on diet, body mass index and blood lipids in patients at cardiovascular risk

    NARCIS (Netherlands)

    Woollard, J.; Burke, V.; Beilin, L.J.; Verheijden, M.W.; Bulsara, M.K.

    2003-01-01

    Background General practice-based health-promotion programmes implemented by nurse-counsellors may reduce cardiovascular risk factors, particularly in patients at increased risk. Neither change in fat intake nor serum cholesterol differed significantly between groups. Body mass index increased in

  15. Childhood body mass index in relation to subsequent risk of type 1 diabetes-A Danish cohort study

    DEFF Research Database (Denmark)

    Antvorskov, Julie C; Aunsholt, Lise; Buschard, Karsten

    2018-01-01

    . The study included 238 cases and 10 147 controls selected from the Copenhagen School Health Record Register (CSHRR). Cases of T1D were identified in the Danish Registry of Childhood and Adolescent Diabetes and 2 regional studies and linked to CSHRR. Using conditional logistic regression models......The incidence of type 1 diabetes (T1D) is increasing, and obesity may be a contributing factor by increasing the risk and accelerating the onset. We investigated the relation between childhood body mass index z-scores (BMIz) and the later risk of T1D, including association with age at onset of T1D...... BMIz at 7 and 13 years of age and the age of onset (P = .34 and P = .42, respectively). Increased BMIz is associated with a moderate increase in risk of T1D, but with no relation to age at onset within the analyzed age range. Increased BMIz over time is unlikely to explain the rising incidence of T1D....

  16. Leisure-time physical activity from mid- to late life, body mass index, and risk of dementia.

    Science.gov (United States)

    Tolppanen, Anna-Maija; Solomon, Alina; Kulmala, Jenni; Kåreholt, Ingemar; Ngandu, Tiia; Rusanen, Minna; Laatikainen, Tiina; Soininen, Hilkka; Kivipelto, Miia

    2015-04-01

    Physical activity may be beneficial for cognition, but the effect may vary depending on personal characteristics. We investigated the associations between leisure-time physical activity (LTPA) from mid- to late life, the risk of dementia, and the role of body mass index, sex, and APOE in the CAIDE study during 28-year follow-up. Cognitive function of a random subsample was assessed at a mean age of 78.8 years (n = 1511), and dementia/Alzheimer's disease (AD) diagnoses were identified from national registers for the entire target population (n = 3559). Moderate (hazard ratio [HR], 1.46; 95% confidence interval [CI], 1.08-1.99) and low levels of midlife LTPA (HR, 1.39; 95% CI, 0.99-1.95) were associated with higher risk of dementia in comparison with the most active category. The benefits were more pronounced among men, overweight individuals, and APOE ε4 noncarriers. Maintaining high LTPA (HR, 0.16; 95% CI, 0.06-0.41) or increasing LTPA (HR, 0.19; 95% CI, 0.09-0.40) after midlife was associated with lower dementia risk. Similar results were observed for AD. The window of opportunity for preventive physical activity interventions may extend from midlife to older ages. Copyright © 2015 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  17. Validation of a second-generation multivariate index assay for malignancy risk of adnexal masses.

    Science.gov (United States)

    Coleman, Robert L; Herzog, Thomas J; Chan, Daniel W; Munroe, Donald G; Pappas, Todd C; Smith, Alan; Zhang, Zhen; Wolf, Judith

    2016-07-01

    Women with adnexal mass suspected of ovarian malignancy are likely to benefit from consultation with a gynecologic oncologist, but imaging and biomarker tools to ensure this referral show low sensitivity and may miss cancer at critical stages. The multivariate index assay (MIA) was designed to improve the detection of ovarian cancer among women undergoing surgery for a pelvic mass. To improve the prediction of benign masses, we undertook the redesign and validation of a second-generation MIA (MIA2G). MIA2G was developed using banked serum samples from a previously published prospective, multisite registry of patients who underwent surgery to remove an adnexal mass. Clinical validity was then established using banked serum samples from the OVA500 trial, a second prospective cohort of adnexal surgery patients. Based on the final pathology results of the OVA500 trial, this intended-use population for MIA2G testing was high risk, with an observed cancer prevalence of 18.7% (92/493). Coded samples were assayed for MIA2G biomarkers by an external clinical laboratory. Then MIA2G results were calculated and submitted to a clinical statistics contract organization for decoding and comparison to MIA results for each subject. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated, among other measures, and stratified by menopausal status, stage, and histologic subtype. Three MIA markers (cancer antigen 125, transferrin, and apolipoprotein A-1) and 2 new biomarkers (follicle-stimulating hormone and human epididymis protein 4) were included in MIA2G. A single cut-off separated high and low risk of malignancy regardless of patient menopausal status, eliminating potential for confusion or error. MIA2G specificity (69%, 277/401 [n/N]; 95% confidence interval [CI], 64.4-73.4%) and PPV (40%, 84/208; 95% CI, 33.9-47.2%) were significantly improved over MIA (specificity, 54%, 215/401; 95% CI, 48.7-58.4%, and PPV, 31%, 85/271; 95

  18. Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study.

    Science.gov (United States)

    McLean, Robert R; Kiel, Douglas P; Berry, Sarah D; Broe, Kerry E; Zhang, Xiaochun; Cupples, L Adrienne; Hannan, Marian T

    2018-01-05

    Although muscle mass influences strength in older adults, it is unclear whether low lean mass measured by dual-energy X-ray absorptiometry (DXA) is an independent risk factor for hip fracture. Our objective was to determine the association between DXA lean mass and incident hip fracture risk among 1978 women aged 50 years and older participating in the Framingham Study Original and Offspring cohorts. Leg and total body lean mass (kg) were assessed from whole-body DXA scans collected in 1992-2001. Hip fracture follow-up extended from DXA assessment to the occurrence of fracture, death, drop-out, or end of follow-up in 2007. Cox proportional hazards regression was used to calculate hazard ratios (HR) and 95% confidence intervals (CI) estimating the relative risk of hip fracture associated with a 1-kg increase in baseline lean mass. Mean age was 66 years (range 50-93). Over a median of 8 years of follow-up, 99 hip fractures occurred. In models adjusted for age, height, study cohort, and percent total body fat, neither leg (HR 1.11; 95% CI 0.94, 1.31) nor total body (HR 1.06; 95% CI 0.99, 1.13) lean mass were associated with hip fracture. After further adjustment for femoral neck bone mineral density, leg lean mass results were similar (HR 1.10; 95% CI 0.93, 1.30). In contrast, 1 kg greater total body lean mass was associated with 9% higher hip fracture risk (HR 1.09; 95% CI 1.02, 1.18). Our findings suggest that in women, lower lean mass measured by DXA is not associated with increased risk of hip fracture.

  19. Association of a body mass index genetic risk score with growth throughout childhood and adolescence.

    Directory of Open Access Journals (Sweden)

    Nicole M Warrington

    Full Text Available While the number of established genetic variants associated with adult body mass index (BMI is growing, the relationships between these variants and growth during childhood are yet to be fully characterised. We examined the association between validated adult BMI associated single nucleotide polymorphisms (SNPs and growth trajectories across childhood. We investigated the timing of onset of the genetic effect and whether it was sex specific.Children from the ALSPAC and Raine birth cohorts were used for analysis (n = 9,328. Genotype data from 32 adult BMI associated SNPs were investigated individually and as an allelic score. Linear mixed effects models with smoothing splines were used for longitudinal modelling of the growth parameters and measures of adiposity peak and rebound were derived.The allelic score was associated with BMI growth throughout childhood, explaining 0.58% of the total variance in BMI in females and 0.44% in males. The allelic score was associated with higher BMI at the adiposity peak (females  =  0.0163 kg/m(2 per allele, males  =  0.0123 kg/m(2 per allele and earlier age (-0.0362 years per allele in males and females and higher BMI (0.0332 kg/m(2 per allele in females and 0.0364 kg/m(2 per allele in males at the adiposity rebound. No gene:sex interactions were detected for BMI growth.This study suggests that known adult genetic determinants of BMI have observable effects on growth from early childhood, and is consistent with the hypothesis that genetic determinants of adult susceptibility to obesity act from early childhood and develop over the life course.

  20. Documentation of body mass index and control of associated risk factors in a large primary care network

    Directory of Open Access Journals (Sweden)

    Grant Richard W

    2009-12-01

    Full Text Available Abstract Background Body mass index (BMI will be a reportable health measure in the United States (US through implementation of Healthcare Effectiveness Data and Information Set (HEDIS guidelines. We evaluated current documentation of BMI, and documentation and control of associated risk factors by BMI category, based on electronic health records from a 12-clinic primary care network. Methods We conducted a cross-sectional analysis of 79,947 active network patients greater than 18 years of age seen between 7/05 - 12/06. We defined BMI category as normal weight (NW, 18-24.9 kg/m2, overweight (OW, 25-29.9, and obese (OB, ≥ 30. We measured documentation (yes/no and control (above/below of the following three risk factors: blood pressure (BP ≤130/≤85 mmHg, low-density lipoprotein (LDL ≤130 mg/dL (3.367 mmol/L, and fasting glucose Results BMI was documented in 48,376 patients (61%, range 34-94%, distributed as 30% OB, 34% OW, and 36% NW. Documentation of all three risk factors was higher in obesity (OB = 58%, OW = 54%, NW = 41%, p for trend Conclusions In a large primary care network BMI documentation has been incomplete and for patients with BMI measured, risk factor control has been poorer in obese patients compared with NW, even in those with obesity and CVD or diabetes. Better knowledge of BMI could provide an opportunity for improved quality in obesity care.

  1. The role of mass media campaigns in reducing high-risk drinking among college students.

    Science.gov (United States)

    DeJong, William

    2002-03-01

    This article categorizes and describes current media campaigns to reduce college student drinking, reviews key principles of campaign design and outlines recommendations for future campaigns. The article describes three types of media campaigns on student drinking: information, social norms marketing, and advocacy. Key principles of campaign design are derived from work in commercial marketing, advertising, and public relations and from evaluations of past public health campaigns. Information campaigns on the dangers of high-risk drinking are common, but none has been rigorously evaluated. Quasi-experimental studies suggest that social norms marketing campaigns, which correct misperceptions of campus drinking norms, may be effective, but more rigorous research is needed. As of this writing, only one major media campaign has focused on policy advocacy to reduce college student drinking, but it is still being evaluated. Lessons for campaign design are organized as a series of steps for campaign development, implementation and assessment: launch a strategic planning process, select a strategic objective, select the target audience, develop a staged approach, define the key promise, avoid fear appeals, select the right message source, select a mix of media channels, maximize media exposure, conduct formative research, and conduct process and outcome evaluations. Future campaigns should integrate information, social norms marketing, and advocacy approaches to create a climate of support for institutional, community and policy changes that will alter the environment in which students make decisions about their alcohol consumption.

  2. Non-participation during azithromycin mass treatment for trachoma in The Gambia: heterogeneity and risk factors.

    Directory of Open Access Journals (Sweden)

    Tansy Edwards

    2014-08-01

    Full Text Available There is concern that untreated individuals in mass drug administration (MDA programs for neglected tropical diseases can reduce the impact of elimination efforts by maintaining a source of transmission and re-infection.Treatment receipt was recorded against the community census during three MDAs with azithromycin for trachoma in The Gambia, a hypo-endemic setting. Predictors of non-participation were investigated in 1-9 year olds using random effects logistic regression of cross-sectional data for each MDA. Two types of non-participators were identified: present during MDA but not treated (PNT and eligible for treatment but absent during MDA (EBA. PNT and EBA children were compared to treated children separately. Multivariable models were developed using baseline data and validated using year one and two data, with a priori adjustment for previous treatment status. Analyses included approximately 10000 children at baseline and 5000 children subsequently. There was strong evidence of spatial heterogeneity, and persistent non-participation within households and individuals. By year two, non-participation increased significantly to 10.4% overall from 6.2% at baseline, with more, smaller geographical clusters of non-participating households. Multivariable models suggested household level predictors of non-participation (increased time to water and household head non-participation for both PNT and EBA; increased household size for PNT status only; non-inclusion in a previous trachoma examination survey and younger age for EBA only. Enhanced coverage efforts did not decrease non-participation. Few infected children were detected at year three and only one infected child was EBA previously. Infected children were in communities close to untreated endemic areas with higher rates of EBA non-participation during MDA.In hypo-endemic settings, with good coverage and no association between non-participation and infection, efforts to improve participation

  3. Body adiposity index versus body mass index and other anthropometric traits as correlates of cardiometabolic risk factors.

    Directory of Open Access Journals (Sweden)

    Charlene T Lichtash

    Full Text Available The worldwide prevalence of obesity mandates a widely accessible tool to categorize adiposity that can best predict associated health risks. The body adiposity index (BAI was designed as a single equation to predict body adiposity in pooled analysis of both genders. We compared body adiposity index (BAI, body mass index (BMI, and other anthropometric measures, including percent body fat (PBF, in their correlations with cardiometabolic risk factors. We also compared BAI with BMI to determine which index is a better predictor of PBF.The cohort consisted of 698 Mexican Americans. We calculated correlations of BAI, BMI, and other anthropometric measurements (PBF measured by dual energy X-ray absorptiometry, waist and hip circumference, height, weight with glucose homeostasis indices (including insulin sensitivity and insulin clearance from euglycemic clamp, lipid parameters, cardiovascular traits (including carotid intima-media thickness, and biomarkers (C-reactive protein, plasminogen activator inhibitor-1 and adiponectin. Correlations between each anthropometric measure and cardiometabolic trait were compared in both sex-pooled and sex-stratified groups.BMI was associated with all but two measured traits (carotid intima-media thickness and fasting glucose in men, while BAI lacked association with several variables. BAI did not outperform BMI in its associations with any cardiometabolic trait. BAI was correlated more strongly than BMI with PBF in sex-pooled analyses (r = 0.78 versus r = 0.51, but not in sex-stratified analyses (men, r = 0.63 versus r = 0.79; women, r = 0.69 versus r = 0.77. Additionally, PBF showed fewer correlations with cardiometabolic risk factors than BMI. Weight was more strongly correlated than hip with many of the cardiometabolic risk factors examined.BAI is inferior to the widely used BMI as a correlate of the cardiometabolic risk factors studied. Additionally, BMI's relationship with total adiposity

  4. Birth weight, childhood body mass index and risk of coronary heart disease in adults: combined historical cohort studies.

    Directory of Open Access Journals (Sweden)

    Lise Geisler Andersen

    Full Text Available BACKGROUND: Low birth weight and high childhood body mass index (BMI is each associated with an increased risk of coronary heart disease (CHD in adult life. We studied individual and combined associations of birth weight and childhood BMI with the risk of CHD in adulthood. METHODS/PRINCIPAL FINDINGS: Birth weight and BMI at age seven years were available in 216,771 Danish and Finnish individuals born 1924-1976. Linkage to national registers for hospitalization and causes of death identified 8,805 CHD events during up to 33 years of follow-up (median = 24 years after age 25 years. Analyses were conducted with Cox regression based on restricted cubic splines. Using median birth weight of 3.4 kg as reference, a non-linear relation between birth weight and CHD was found. It was not significantly different between cohorts, or between men and women, nor was the association altered by childhood BMI. For birth weights below 3.4 kg, the risk of CHD increased linearly and reached 1.28 (95% confidence limits: 1.13 to 1.44 at 2 kg. Above 3.4 kg the association weakened, and from about 4 kg there was virtually no association. BMI at age seven years was strongly positively associated with the risk of CHD and the relation was not altered by birth weight. The excess risk in individuals with a birth weight of 2.5 kg and a BMI of 17.7 kg/m(2 at age seven years was 44% (95% CI: 30% to 59% compared with individuals with median values of birth weight (3.4 kg and BMI (15.3 kg/m(2. CONCLUSIONS/SIGNIFICANCE: Birth weight and BMI at age seven years appeared independently associated with the risk of CHD in adulthood. From a public health perspective we suggest that particular attention should be paid to children with a birth weight below the average in combination with excess relative weight in childhood.

  5. Mass-gathering Medicine: Risks and Patient Presentations at a 2-Day Electronic Dance Music Event.

    Science.gov (United States)

    Lund, Adam; Turris, Sheila A

    2015-06-01

    Music festivals, including electronic dance music events (EDMEs), increasingly are common in Canada and internationally. Part of a US $4.5 billion industry annually, the target audience is youth and young adults aged 15-25 years. Little is known about the impact of these events on local emergency departments (EDs). Drawing on prospective data over a 2-day EDME, the authors of this study employed mixed methods to describe the case mix and prospectively compared patient presentation rate (PPR) and ambulance transfer rate (ATR) between a first aid (FA) only and a higher level of care (HLC) model. There were 20,301 ticketed attendees. Seventy patient encounters were recorded over two days. The average age was 19.1 years. Roughly 69% were female (n=48/70). Forty-six percent of those seen in the main medical area were under the age of 19 years (n=32/70). The average length of stay in the main medical area was 70.8 minutes. The overall PPR was 4.09 per 1,000 attendees. The ATR with FA only would have been 1.98; ATR with HLC model was 0.52. The presence of an on-site HLC team had a significant positive effect on avoiding ambulance transfers. Twenty-nine ambulance transfers and ED visits were avoided by the presence of an on-site HLC medical team. Reduction of impact to the public health care system was substantial. Electronic dance music events have predictable risks and patient presentations, and appropriate on-site health care resources may reduce significantly the impact on the prehospital and emergency health resources in the host community.

  6. Prevalence of cardiovascular risk factors in youth with type 1 diabetes and elevated body mass index.

    Science.gov (United States)

    Redondo, Maria J; Foster, Nicole C; Libman, Ingrid M; Mehta, Sanjeev N; Hathway, Joanne M; Bethin, Kathleen E; Nathan, Brandon M; Ecker, Michelle A; Shah, Avni C; DuBose, Stephanie N; Tamborlane, William V; Hoffman, Robert P; Wong, Jenise C; Maahs, David M; Beck, Roy W; DiMeglio, Linda A

    2016-04-01

    The prevalence of cardiovascular risk factors in children with type 1 diabetes and elevated BMI in the USA is poorly defined. We aimed to test the hypothesis that children with type 1 diabetes who are overweight or obese have increased frequencies of hypertension, dyslipidemia, and micro-/macroalbuminuria compared to their healthy weight peers. We studied 11,348 children 2 to 18 years of age enrolled in T1D Exchange between September 2010 and August 2012 with type 1 diabetes for ≥1 year and BMI ≥ 5th age-/sex-adjusted percentile (mean age 12 years, 49 % female, 78 % non-Hispanic White). Overweight and obesity were defined based on Centers for Disease Control and Prevention criteria. Diagnoses of hypertension, dyslipidemia, and micro-/macroalbuminuria were obtained from medical records. Logistic and linear regression models were used to assess factors associated with weight status. Of the 11,348 participants, 22 % were overweight and 14 % obese. Hypertension and dyslipidemia were diagnosed in 1.0 % and 3.8 % of participants, respectively; micro-/macroalbuminuria was diagnosed in 3.8 % of participants with available data (n = 7,401). The odds of either hypertension or dyslipidemia were higher in obese than healthy weight participants [OR 3.5, 99 % confidence interval (CI) 2.0-6.1 and 2.2, 99 % CI 1.6-3.1, respectively]. Obese participants tended to be diagnosed with micro-/macroalbuminuria less often than healthy weight participants (OR 0.6, 99 % CI 0.4-1.0). Obese children with type 1 diabetes have a higher prevalence of hypertension and dyslipidemia than healthy weight children with type 1 diabetes. The possible association of obesity with lower micro-/macroalbuminuria rates warrants further investigation.

  7. Prevention and surveillance of public health risks during extended mass gatherings in rural areas: the experience of the Tamworth Country Music Festival, Australia.

    Science.gov (United States)

    Polkinghorne, B G; Massey, P D; Durrheim, D N; Byrnes, T; MacIntyre, C R

    2013-01-01

    To describe and evaluate the public health response to the Tamworth Country Music Festival, an annual extended mass gathering in rural New South Wales, Australia; and to propose a framework for responding to similar rural mass gatherings. Process evaluation by direct observation, archival analysis and focus group discussion. The various components of the public health response to the 2011 Tamworth Country Music Festival were actively recorded. An archival review of documentation from 2007 to 2010 was performed to provide context. A focus group was also conducted to discuss the evolution of the public health response and the consequences of public health involvement. Public health risks increased with increasing duration of the rural mass gathering. Major events held within the rural mass gathering further strained resources. The prevention, preparedness, response and recovery principles provided a useful framework for public health actions. Particular risks included inadequately trained food preparation volunteers functioning in poorly equipped temporary facilities, heat-related ailments and arboviral disease. Extended mass gatherings in rural areas pose particular public health challenges; surge capacity is limited and local infrastructure may be overwhelmed in the event of an acute incident or outbreak. There is value in proactive public health surveillance and monitoring. Annual mass gatherings provide opportunities for continual systems improvement. Early multi-agency planning can identify key risks and identify opportunities for partnership. Special consideration is required for major events within mass gatherings. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  8. Waist Circumference, Body Mass Index, and Other Measures of Adiposity in Predicting Cardiovascular Disease Risk Factors among Peruvian Adults.

    Science.gov (United States)

    Knowles, K M; Paiva, L L; Sanchez, S E; Revilla, L; Lopez, T; Yasuda, M B; Yanez, N D; Gelaye, B; Williams, M A

    2011-01-24

    Objectives. To examine the extent to which measures of adiposity can be used to predict selected components of metabolic syndrome (MetS) and elevated C-reactive protein (CRP). Methods. A total of 1,518 Peruvian adults were included in this study. Waist circumference (WC), body mass index (BMI), waist-hip ratio (WHR), waist-height ratio (WHtR), and visceral adiposity index (VAI) were examined. The prevalence of each MetS component was determined according to tertiles of each anthropometric measure. ROC curves were used to evaluate the extent to which measures of adiposity can predict cardiovascular risk. Results. All measures of adiposity had the strongest correlation with triglyceride concentrations (TG). For both genders, as adiposity increased, the prevalence of Mets components increased. Compared to individuals with low-BMI and low-WC, men and women with high-BMI and high- WC had higher odds of elevated fasting glucose, blood pressure, TG, and reduced HDL, while only men in this category had higher odds of elevated CRP. Overall, the ROCs showed VAI, WC, and WHtR to be the best predictors for individual MetS components. Conclusions. The results of our study showed that measures of adiposity are correlated with cardiovascular risk although no single adiposity measure was identified as the best predictor for MetS.

  9. Waist Circumference, Body Mass Index, and Other Measures of Adiposity in Predicting Cardiovascular Disease Risk Factors among Peruvian Adults

    Directory of Open Access Journals (Sweden)

    K. M. Knowles

    2011-01-01

    Full Text Available Objectives. To examine the extent to which measures of adiposity can be used to predict selected components of metabolic syndrome (MetS and elevated C-reactive protein (CRP. Methods. A total of 1,518 Peruvian adults were included in this study. Waist circumference (WC, body mass index (BMI, waist-hip ratio (WHR, waist-height ratio (WHtR, and visceral adiposity index (VAI were examined. The prevalence of each MetS component was determined according to tertiles of each anthropometric measure. ROC curves were used to evaluate the extent to which measures of adiposity can predict cardiovascular risk. Results. All measures of adiposity had the strongest correlation with triglyceride concentrations (TG. For both genders, as adiposity increased, the prevalence of Mets components increased. Compared to individuals with low-BMI and low-WC, men and women with high-BMI and high- WC had higher odds of elevated fasting glucose, blood pressure, TG, and reduced HDL, while only men in this category had higher odds of elevated CRP. Overall, the ROCs showed VAI, WC, and WHtR to be the best predictors for individual MetS components. Conclusions. The results of our study showed that measures of adiposity are correlated with cardiovascular risk although no single adiposity measure was identified as the best predictor for MetS.

  10. Effect of Accounting for Crash Severity on the Relationship between Mass Reduction and Crash Frequency and Risk per Crash

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Tom P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Building Technology and Urban Systems Division. Energy Technologies Area

    2016-05-20

    Previous analyses have indicated that mass reduction is associated with an increase in crash frequency (crashes per VMT), but a decrease in fatality or casualty risk once a crash has occurred, across all types of light-duty vehicles. These results are counter-intuitive: one would expect that lighter, and perhaps smaller, vehicles have better handling and shorter braking distances, and thus should be able to avoid crashes that heavier vehicles cannot. And one would expect that heavier vehicles would have lower risk once a crash has occurred than lighter vehicles. However, these trends occur under several alternative regression model specifications. This report tests whether these results continue to hold after accounting for crash severity, by excluding crashes that result in relatively minor damage to the vehicle(s) involved in the crash. Excluding non-severe crashes from the initial LBNL Phase 2 and simultaneous two-stage regression models for the most part has little effect on the unexpected relationships observed in the baseline regression models. This finding suggests that other subtle differences in vehicles and/or their drivers, or perhaps biases in the data reported in state crash databases, are causing the unexpected results from the regression models.

  11. The estimated effect of mass or footprint reduction in recent light-duty vehicles on U.S. societal fatality risk per vehicle mile traveled.

    Science.gov (United States)

    Wenzel, Tom

    2013-10-01

    The National Highway Traffic Safety Administration (NHTSA) recently updated its 2003 and 2010 logistic regression analyses of the effect of a reduction in light-duty vehicle mass on US societal fatality risk per vehicle mile traveled (VMT; Kahane, 2012). Societal fatality risk includes the risk to both the occupants of the case vehicle as well as any crash partner or pedestrians. The current analysis is the most thorough investigation of this issue to date. This paper replicates the Kahane analysis and extends it by testing the sensitivity of his results to changes in the definition of risk, and the data and control variables used in the regression models. An assessment by Lawrence Berkeley National Laboratory (LBNL) indicates that the estimated effect of mass reduction on risk is smaller than in Kahane's previous studies, and is statistically non-significant for all but the lightest cars (Wenzel, 2012a). The estimated effects of a reduction in mass or footprint (i.e. wheelbase times track width) are small relative to other vehicle, driver, and crash variables used in the regression models. The recent historical correlation between mass and footprint is not so large to prohibit including both variables in the same regression model; excluding footprint from the model, i.e. allowing footprint to decrease with mass, increases the estimated detrimental effect of mass reduction on risk in cars and crossover utility vehicles (CUVs)/minivans, but has virtually no effect on light trucks. Analysis by footprint deciles indicates that risk does not consistently increase with reduced mass for vehicles of similar footprint. Finally, the estimated effects of mass and footprint reduction are sensitive to the measure of exposure used (fatalities per induced exposure crash, rather than per VMT), as well as other changes in the data or control variables used. It appears that the safety penalty from lower mass can be mitigated with careful vehicle design, and that manufacturers can

  12. Strategies for reducing body fat mass: effects of liposuction and exercise on cardiovascular risk factors and adiposity

    Directory of Open Access Journals (Sweden)

    Benatti FB

    2011-04-01

    Full Text Available Fabiana Braga Benatti1, Fábio Santos Lira2, Lila Missae Oyama2, Cláudia Maria da Penha Oller do Nascimento2, Antonio Herbert Lancha Junior11School of Physical Education and Sport, University of Sao Paulo, Sao Paulo, Brazil; 2Department of Physiology, Division of Nutrition Physiology, Federal University of Sao Paulo, Sao Paulo, BrazilAbstract: Liposuction is the most popular aesthetic surgery performed in Brazil and worldwide. Evidence showing that adipose tissue is a metabolically active tissue has led to the suggestion that liposuction could be a viable method for improving metabolic profile through the immediate loss of adipose tissue. However, the immediate liposuction-induced increase in the proportion of visceral to subcutaneous adipose tissue could be detrimental to metabolism, because a high proportion of visceral to subcutaneous adipose tissue is associated with risk factors for cardiovascular disease. The results of studies investigating the effects of liposuction on the metabolic profile are inconsistent, however, with most studies reporting either no change or improvements in one or more cardiovascular risk factors. In addition, animal studies have demonstrated a compensatory growth of intact adipose tissue in response to lipectomy, although studies with humans have reported inconsistent results. Exercise training improves insulin sensitivity, inflammatory balance, lipid oxidation, and adipose tissue distribution; increases or preserves the fat-free mass; and increases total energy expenditure. Thus, liposuction and exercise appear to directly affect metabolism in similar ways, which suggests a possible interaction between these two strategies. To our knowledge, no studies have reported the associated effects of liposuction and exercise in humans. Nonetheless, one could suggest that exercise training associated with liposuction could attenuate or even block the possible compensatory fat deposition in intact depots or regrowth of the

  13. Incongruence in body image and body mass index: A surrogate risk marker in Black women for type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Rynal Devanathan

    2013-07-01

    Full Text Available Background: Excess weight contributes to the development and progression of Type 2 diabetes mellitus (T2DM. Distorted body image amongst urban Black women and the perception that thinness is linked with HIV, may however be compounding the problem, particularly in areas with a high HIV burden. Objectives: This study aimed to compare the perception of body image in urban Black women with and without T2DM. Methods: A cross-sectional comparative study was conducted on 328 Black women systematically sampled into two groups (with and without T2DM. Body mass index (BMI (weight [kg]/height[m2] was determined and the adapted Stunkard Body Image Silhouettes for Black women was used to determine perceived body image (PBI. Results: Seventy-two per cent had T2DM and in this group 89% were obese, with a mean BMI of 39.5 kg/m2 (s.d. ± 8.5. In the non-diabetes group (NDG 44% were obese, with a mean BMIof 31.3 kg/m2 (s.d. ± 9.0 Black women underestimated their body image across all weight categories (p < 0.05. Both groups (99% of the study group also perceived thinness as being associated with HIV. Conclusions: This study identified an incongruence between PBI and actual BMI amongst urban Black women. This, combined with their belief that thinness is associated with HIV, places those with T2DM at risk of secondary complications arising from diabetes mellitus, and those without diabetes mellitus at a higher risk of developing T2DM. A discrepancy between PBI and BMI may therefore serve as a risk marker to alert clinicians to use a more ethno-cultural specific approach in engaging with urban Black women regarding weight loss strategies in the future.

  14. An Analysis of the Relationship between Casualty Risk Per Crash and Vehicle Mass and Footprint for Model Year 2003-2010 Light-Duty Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Tom P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2018-01-05

    The Department of Energy’s (DOE) Vehicle Technologies Office funds research on development of technologies to improve the fuel economy of both light- and heavy-duty vehicles, including advanced combustion systems, improved batteries and electric drive systems, and new lightweight materials. Of these approaches to increase fuel economy and reduce fuel consumption, reducing vehicle mass through more extensive use of strong lightweight materials is perhaps the easiest and least expensive method; however, there is a concern that reducing vehicle mass may lead to more fatalities. Lawrence Berkeley National Laboratory (LBNL) has conducted several analyses to better understand the relationship between vehicle mass, size and safety, in order to ameliorate concerns that down-weighting vehicles will inherently lead to more fatalities. These analyses include recreating the regression analyses conducted by the National Highway Traffic Safety Administration (NHTSA) that estimate the relationship between mass reduction and U.S. societal fatality risk per vehicle mile of travel (VMT), while holding vehicle size (i.e. footprint, wheelbase times track width) constant; these analyses are referred to as LBNL Phase 1 analysis. In addition, LBNL has conducted additional analysis of the relationship between mass and the two components of risk per VMT, crash frequency (crashes per VMT) and risk once a crash has occurred (risk per crash); these analyses are referred to as LBNL Phase 2 analysis.

  15. Mass movements in the Rio Grande Valley (Quebrada de Humahuaca, Northwestern Argentina): a methodological approach to reduce the risk

    Science.gov (United States)

    Marcato, G.; Pasuto, A.; Rivelli, F. R.

    2009-10-01

    Slope processes such as slides and debris flows, are among the main events that induce effects on the Rio Grande sediment transport capacity. The slides mainly affect the slope of the Rio Grande river basin while debris and mud flows phenomena take place in the tributary valleys. In the past decades several mass movements occurred causing victims and great damages to roads and villages and therefore hazard assessment and risk mitigation is of paramount importance for a correct development of the area. This is also an urgent need since the Quebrada de Humahuaca was recently included in the UNESCO World Cultural Heritage. The growing tourism business may lead to an uncontrolled urbanization of the valley with the consequent enlargement of threatened areas. In this framework mitigation measures have to take into account not only technical aspects related to the physical behaviour of the moving masses but also environmental and sociological factors that could influence the effectiveness of the countermeasures. Mitigation of landslide effects is indeed rather complex because of the large extension of the territory and the particular geological and geomorphological setting. Moreover the necessity to maintain the natural condition of the area as prescribed by UNESCO, make this task even more difficult. Nowadays no in-depth study of the entire area exists, therefore an integrated and multidisciplinary investigation plan is going to be set up including geological and geomorphological investigations as well as archaeological and historical surveys. The better understanding of geomorphological evolution processes of the Quebrada de Humahuaca will bridge the gap between the necessity of preservation and the request of safety keeping of the recommendation by UNESCO.

  16. Evaluation of mass spectrometry of urinary proteins and peptides as biomarkers for cats at risk of developing azotemia.

    Science.gov (United States)

    Jepson, Rosanne E; Coulton, Gary R; Cowan, Matthew L; Markwell, Peter; Syme, Harriet M; Elliott, Jonathan

    2013-02-01

    To evaluate proteomic delineation of feline urine by mass spectrometry as a method for identifying biomarkers in cats at risk of developing azotemia. Urine samples from geriatric cats (> 9 years old) with chronic kidney disease and nonazotemic cats that either remained nonazotemic (n = 10) or developed azotemia (10) within 1 year. Optimization studies with pooled urine were performed to facilitate the use of surface enhanced laser desorption-ionization time-of-flight mass spectrometry (SELDI-TOF-MS) for analysis of the urinary proteome of cats. Urine samples from nonazotemic cats at entry to the study were analyzed via SELDI-TOF-MS with weak cation exchange and strong anion exchange arrays. Spectral data were compared to identify biomarkers for development of azotemia. Low protein concentration in feline urine precluded direct application to array surfaces, and a buffer exchange and concentration step was required prior to SELDI-TOF-MS analysis. Three preparation conditions by use of weak cation and strong anion exchange arrays were selected on the basis of optimization studies for detection of biomarkers. Eight potential biomarkers with an m/z of 2,822, 9,886, 10,033, 10,151, 10,234, 11,653, 4,421, and 9,505 were delineated. SELDI-TOF-MS can be used to detect urinary low-molecular weight peptides and proteins that may represent biomarkers for early detection of renal damage. Further study is required to purify and identify potential biomarkers before their use in a clinical setting.

  17. Mass movements in the Rio Grande Valley (Quebrada de Humahuaca, Northwestern Argentina: a methodological approach to reduce the risk

    Directory of Open Access Journals (Sweden)

    G. Marcato

    2009-10-01

    Full Text Available Slope processes such as slides and debris flows, are among the main events that induce effects on the Rio Grande sediment transport capacity. The slides mainly affect the slope of the Rio Grande river basin while debris and mud flows phenomena take place in the tributary valleys. In the past decades several mass movements occurred causing victims and great damages to roads and villages and therefore hazard assessment and risk mitigation is of paramount importance for a correct development of the area. This is also an urgent need since the Quebrada de Humahuaca was recently included in the UNESCO World Cultural Heritage. The growing tourism business may lead to an uncontrolled urbanization of the valley with the consequent enlargement of threatened areas.

    In this framework mitigation measures have to take into account not only technical aspects related to the physical behaviour of the moving masses but also environmental and sociological factors that could influence the effectiveness of the countermeasures.

    Mitigation of landslide effects is indeed rather complex because of the large extension of the territory and the particular geological and geomorphological setting. Moreover the necessity to maintain the natural condition of the area as prescribed by UNESCO, make this task even more difficult.

    Nowadays no in-depth study of the entire area exists, therefore an integrated and multidisciplinary investigation plan is going to be set up including geological and geomorphological investigations as well as archaeological and historical surveys. The better understanding of geomorphological evolution processes of the Quebrada de Humahuaca will bridge the gap between the necessity of preservation and the request of safety keeping of the recommendation by UNESCO.

  18. Saturated fat intake modulates the association between an obesity genetic risk score and body mass index in two US populations.

    Science.gov (United States)

    Casas-Agustench, Patricia; Arnett, Donna K; Smith, Caren E; Lai, Chao-Qiang; Parnell, Laurence D; Borecki, Ingrid B; Frazier-Wood, Alexis C; Allison, Matthew; Chen, Yii-Der Ida; Taylor, Kent D; Rich, Stephen S; Rotter, Jerome I; Lee, Yu-Chi; Ordovás, José M

    2014-12-01

    Combining multiple genetic variants related to obesity into a genetic risk score (GRS) might improve identification of individuals at risk of developing obesity. Moreover, characterizing gene-diet interactions is a research challenge to establish dietary recommendations to individuals with higher predisposition to obesity. Our objective was to analyze the association between an obesity GRS and body mass index (BMI) in the Genetics of Lipid Lowering Drugs and Diet Network (GOLDN) population, focusing on gene-diet interactions with total fat and saturated fatty acid (SFA) intake, and to replicate findings in the Multi-Ethnic Study of Atherosclerosis (MESA) population. Cross-sectional analyses included 783 white US participants from GOLDN and 2,035 from MESA. Dietary intakes were estimated with validated food frequency questionnaires. Height and weight were measured. A weighted GRS was calculated on the basis of 63 obesity-associated variants. Multiple linear regression models adjusted by potential confounders were used to examine gene-diet interactions between dietary intake (total fat and SFA) and the obesity GRS in determining BMI. Significant interactions were found between total fat intake and the obesity GRS using these variables as continuous for BMI (P for interaction=0.010, 0.046, and 0.002 in GOLDN, MESA, and meta-analysis, respectively). These association terms were stronger when assessing interactions between SFA intake and GRS for BMI (P for interaction=0.005, 0.018, and obesity GRS in modulating BMI in two US populations. Although determining the causal direction requires further investigation, these findings suggest that potential dietary recommendations to reduce BMI effectively in populations with high obesity GRS would be to reduce total fat intake mainly by limiting SFAs. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  19. BMI or BIA: Is Body Mass Index or Body Fat Mass a Better Predictor of Cardiovascular Risk in Overweight or Obese Children and Adolescents?

    Directory of Open Access Journals (Sweden)

    Barbara Bohn

    2015-04-01

    Full Text Available Background: Body fat (BF percentiles for German children and adolescents have recently been published. This study aims to evaluate the association between bioelectrical impedance analysis(BIA-derived BF and cardiovascular risk factors and to investigate whether BF is better suited than BMI in children and adolescents. Methods: Data of 3,327 children and adolescents (BMI > 90th percentile were included. Spearman's correlation and receiver operating characteristics (ROCs were applied determining the associations between BMI or BF and cardiovascular risk factors (hypertension, dyslipidemia, elevated liver enzymes, abnormal carbohydrate metabolism. Area under the curve (AUC was calculated to predict cardiovascular risk factors. Results: A significant association between both obesity indices and hypertension was present (all p Conclusion: BIA-derived BF was not superior to BMI to predict cardiovascular risk factors in overweight or obese children and adolescents.

  20. Do body mass index trajectories affect the risk of type 2 diabetes? A case-control study.

    Science.gov (United States)

    Mano, Yoshihiko; Yokomichi, Hiroshi; Suzuki, Kohta; Takahashi, Atsunori; Yoda, Yoshioki; Tsuji, Masahiro; Sato, Miri; Shinohara, Ryoji; Mizorogi, Sonoko; Mochizuki, Mie; Yamagata, Zentaro

    2015-07-28

    Although obesity is a well-studied risk factor for diabetes, there remains an interest in whether "increasing body mass index (BMI)," "high BMI per se," or both are the actual risk factors for diabetes. The present study aimed to retrospectively compare BMI trajectories of individuals with and without diabetes in a case-control design and to assess whether increasing BMI alone would be a risk factor. Using comprehensive health check-up data measured over ten years, we conducted a case-control study and graphically drew the trajectories of BMIs among diabetic patients and healthy subjects, based on coefficients in fitted linear mixed-effects models. Patient group was matched with healthy control group at the onset of diabetes with an optimal matching method in a 1:10 ratio. Simple fixed-effects models assessed the differences in increasing BMIs over 10 years between patient and control groups. At the time of matching, the mean ages in male patients and controls were 59.3 years [standard deviation (SD) = 9.2] and 57.7 years (SD = 11.2), whereas the mean BMIs were 25.0 kg/m(2) (SD = 3.1) and 25.2 kg/m(2) (SD = 2.9), respectively. In female patients and controls, the mean ages were 61.4 years (SD = 7.9) and 60.1 years (SD = 9.6), whereas the mean BMIs were 24.8 kg/m(2) (SD = 3.5) and 24.9 kg/m(2) (SD = 3.4), respectively. The simple fixed-effects models detected no statistical significance for the differences of increasing BMIs between patient and control groups in males (P = 0.19) and females (P = 0.67). Sudden increases in BMI were observed in both male and female patients when compared with BMIs 1 year prior to diabetes onset. The present study suggested that the pace of increasing BMIs is similar between Japanese diabetic patients and healthy individuals. The increasing BMI was not detected to independently affect the onset of type 2 diabetes.