  1. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P.; Margreiter, M.

    2011-01-01

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [de

  2. Value of MR contrast media in image-guided body interventions.

    Science.gov (United States)

    Saeed, Maythem; Wilson, Mark

    2012-01-28

    In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability

  3. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier; Mathelin, Michel de; Jacqmin, Didier; Lang, Herve

    2012-01-01

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  4. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier [University Hospital of Strasbourg, Department of Interventional Radiology, Strasbourg (France); Mathelin, Michel de [University of Strasbourg, Lsiit, Strasbourg (France); Jacqmin, Didier; Lang, Herve [University Hospital of Strasbourg, Department of Urology, Strasbourg (France)

    2012-08-15

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  5. Differentiation of prostatitis and prostate cancer by using diffusion-weighted MR imaging and MR-guided biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, Klaas N.A.; Schouten, Martijn G.; Hambrock, Thomas; Litjens, Geert J.S.; Hoeks, Caroline; ten Haken, Bernard; Barentsz, Jelle O.; Fütterer, Johannes Jacobus; Fütterer, Jurgen J.

    2013-01-01

    Purpose To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference. Materials and Methods The need for institutional review

  6. Differentiation of Prostatitis and Prostate Cancer by Using Diffusion-weighted MR Imaging and MR-guided Biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, K.N.A.; Schouten, M.G.; Hambrock, T.; Litjens, G.J.S.; Hoeks, C.M.A.; Haken, B.T.; Barentsz, J.O.; Futterer, J.J.

    2013-01-01

    Purpose:To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference.Materials and Methods:The need for institutional review board

  7. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  8. Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy

    NARCIS (Netherlands)

    Ven, W.J.M. van de; Hu, Y.; Barentsz, J.O.; Karssemeijer, N.; Barratt, D.; Huisman, H.J.

    2015-01-01

    Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based

  9. Cost-effectiveness of MR Imaging-guided Strategies for Detection of Prostate Cancer in Biopsy-Naive Men.

    Science.gov (United States)

    Pahwa, Shivani; Schiltz, Nicholas K; Ponsky, Lee E; Lu, Ziang; Griswold, Mark A; Gulani, Vikas

    2017-10-01

    Purpose To evaluate the cost-effectiveness of multiparametric diagnostic magnetic resonance (MR) imaging examination followed by MR imaging-guided biopsy strategies in the detection of prostate cancer in biopsy-naive men presenting with clinical suspicion of cancer for the first time. Materials and Methods A decision-analysis model was created for biopsy-naive men who had been recommended for prostate biopsy on the basis of abnormal digital rectal examination results or elevated prostate-specific antigen levels (age groups: 41-50 years, 51-60 years, and 61-70 years). The following three major strategies were evaluated: (a) standard transrectal ultrasonography (US)-guided biopsy; (b) diagnostic MR imaging followed by MR imaging-targeted biopsy, with no biopsy performed if MR imaging findings were negative; and (c) diagnostic MR imaging followed by MR imaging-targeted biopsy, with a standard biopsy performed when MR imaging findings were negative. The following three MR imaging-guided biopsy strategies were further evaluated in each MR imaging category: (a) biopsy with cognitive guidance, (b) biopsy with MR imaging/US fusion guidance, and (c) in-gantry MR imaging-guided biopsy. Model parameters were derived from the literature. The primary outcome measure was net health benefit (NHB), which was measured as quality-adjusted life-years (QALYs) gained or lost by investing resources in a new strategy compared with a standard strategy at a willingness-to-pay (WTP) threshold of $50 000 per QALY gained. Probabilistic sensitivity analysis was performed by using Monte Carlo simulations. Results Noncontrast MR imaging followed by cognitively guided MR biopsy (no standard biopsy if MR imaging findings were negative) was the most cost-effective approach, yielding an additional NHB of 0.198 QALY compared with the standard biopsy approach. Noncontrast MR imaging followed by in-gantry MR imaging-guided biopsy (no standard biopsy if MR imaging findings were negative) led to the

  10. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis

    2013-06-01

    In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  11. TU-F-BRF-02: MR-US Prostate Registration Using Patient-Specific Tissue Elasticity Property Prior for MR-Targeted, TRUS-Guided HDR Brachytherapy

    International Nuclear Information System (INIS)

    Yang, X; Rossi, P; Ogunleye, T; Jani, A; Curran, W; Liu, T

    2014-01-01

    Purpose: High-dose-rate (HDR) brachytherapy has become a popular treatment modality for prostate cancer. Conventional transrectal ultrasound (TRUS)-guided prostate HDR brachytherapy could benefit significantly from MR-targeted, TRUS-guided procedure where the tumor locations, acquired from the multiparametric MRI, are incorporated into the treatment planning. In order to enable this integration, we have developed a MR-TRUS registration with a patient-specific biomechanical elasticity prior. Methods: The proposed method used a biomechanical elasticity prior to guide the prostate volumetric B-spline deformation in the MRI and TRUS registration. The patient-specific biomechanical elasticity prior was generated using ultrasound elastography, where two 3D TRUS prostate images were acquired under different probe-induced pressures during the HDR procedure, which takes 2-4 minutes. These two 3D TRUS images were used to calculate the local displacement (elasticity map) of two prostate volumes. The B-spline transformation was calculated by minimizing the Euclidean distance between the normalized attribute vectors of the prostate surface landmarks on the MR and TRUS. This technique was evaluated through two studies: a prostate-phantom study and a pilot study with 5 patients undergoing prostate HDR treatment. The accuracy of our approach was assessed through the locations of several landmarks in the post-registration and TRUS images; our registration results were compared with the surface-based method. Results: For the phantom study, the mean landmark displacement of the proposed method was 1.29±0.11 mm. For the 5 patients, the mean landmark displacement of the surface-based method was 3.25±0.51 mm; our method, 1.71±0.25 mm. Therefore, our proposed method of prostate registration outperformed the surfaced-based registration significantly. Conclusion: We have developed a novel MR-TRUS prostate registration approach based on patient-specific biomechanical elasticity prior

  12. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Korsager, Anne Sofie; Østergaard, Lasse Riis; Carl, Jesper

    2013-01-01

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  13. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Korsager, Anne Sofie; Ostergaard, Lasse Riis [Department of Health Science and Technology, Aalborg University, Aalborg 9220 (Denmark); Carl, Jesper [Department of Medical Physics, Oncology, Aalborg Hospital, Aalborg 9100 (Denmark)

    2013-06-15

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41 Degree-Sign {+-} 0.45 Degree-Sign and a translation error of 1.67 {+-} 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  14. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  15. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    International Nuclear Information System (INIS)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A; Duiveman, Ed; Van Schelven, Leonard J; De Leeuw, Hendrik

    2010-01-01

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  16. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    Energy Technology Data Exchange (ETDEWEB)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); Duiveman, Ed; Van Schelven, Leonard J [Medical Technology and Clinical Physics, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); De Leeuw, Hendrik [Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands)], E-mail: M.R.vandenBosch@umcutrecht.nl

    2010-03-07

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  17. MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

    Directory of Open Access Journals (Sweden)

    Tsuicheng D Chiu

    Full Text Available Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT imaging alone. In this study, we characterized a research magnetic resonance (MR scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This

  18. MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

    Science.gov (United States)

    Chiu, Tsuicheng D; Arai, Tatsuya J; Campbell Iii, James; Jiang, Steve B; Mason, Ralph P; Stojadinovic, Strahinja

    2018-01-01

    Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol

  19. Percutaneous MR-guided focal cryoablation for recurrent prostate cancer following radiation therapy. Retrospective analysis of iceball margins and outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Overduin, Christiaan G.; Jenniskens, Sjoerd F.M.; Bomers, Joyce G.R. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Sedelaar, J.P.M. [Radboud University Medical Center, Department of Urology, Nijmegen (Netherlands); Fuetterer, Jurgen J. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Engineering and Technical Medicine, Enschede (Netherlands)

    2017-11-15

    To evaluate iceball margins after magnetic resonance (MR)-guided focal salvage prostate cryoablation and determine the correlation with local outcome. A retrospective review was performed on 47 patients that underwent percutaneous MR-guided focal cryoablation for biopsy-proven locally recurrent prostate cancer after primary radiotherapy. Preprocedural diagnostic and intraprocedural MR images were analysed to derive three-directional iceball margins. Local tumour progression after cryoablation was defined as evident tumour recurrence on follow-up MRI, positive MR-guided biopsy or biochemical failure without radiological evidence of metastatic disease. Mean iceball margins were 8.9 mm (range -7.1 to 16.2), 10.1 mm (range 1.1-20.3) and 12.5 mm (range -1.5 to 22.2) in anteroposterior, left-right and craniocaudal direction respectively. Iceball margins were significantly smaller for tumours that were larger (P =.008) or located in the posterior gland (P =.047). Significantly improved local progression-free survival at 1 year post focal cryoablation was seen between patients with iceball margin >10 mm (100%), 5-10 mm (84%) and <5 mm (15%) (P <.001). Iceball margins appear to correlate with local outcome following MR-guided focal salvage prostate cryoablation. Our initial data suggest that freezing should be applied at minimum 5 mm beyond the border of an MR-visible recurrent prostate tumour for successful ablation, with a wider margin appearing desirable. (orig.)

  20. Mr.-Guided Cardiac Interventions Using Mr.-Safe Passive Devices: A Preclinical Study and First-in-Man Congenital Interventions

    NARCIS (Netherlands)

    Tzifa, A.; Krombach, G.A.; Kraemer, N.; Krueger, S.; Schuette, A.; Von Walter, M.; Schaeffter, T.; Qureshi, S.; Krasemann, T.; Rosenthal, E.; Schwartz, C.; Varma, G.; Buhl, A.; Kohlmeier, A.; Buecker, A.; Guenther, R.W.; Razavi, R.

    2011-01-01

    Background: Percutaneous cardiac interventions are currently performed under X-ray guidance. Magnetic resonance imaging has been employed to guide intravascular interventions in the past, but mainly in animals. Translation of MR-guided interventions into humans has been limited by the lack of fully

  1. Multidisciplinary Functional MR Imaging for Prostate Cancer

    International Nuclear Information System (INIS)

    Kim, Jeong Kon; Jang, Yun Jin; Cho, Gyung Goo

    2009-01-01

    Various functional magnetic resonance (MR) imaging techniques are used for evaluating prostate cancer including diffusion-weighted imaging, dynamic contrast- enhanced MR imaging, and MR spectroscopy. These techniques provide unique information that is helpful to differentiate prostate cancer from non-cancerous tissue and have been proven to improve the diagnostic performance of MRI not only for cancer detection, but also for staging, post-treatment monitoring, and guiding prostate biopsies. However, each functional MR imaging technique also has inherent challenges. Therefore, in order to make accurate diagnoses, it is important to comprehensively understand their advantages and limitations, histologic background related with image findings, and their clinical relevance for evaluating prostate cancer. This article will review the basic principles and clinical significance of functional MR imaging for evaluating prostate cancer

  2. MR imaging of the prostate

    International Nuclear Information System (INIS)

    Asbach, P.; Haas, M.; Hamm, B.

    2015-01-01

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [de

  3. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  4. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  5. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2014-10-15

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  6. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter

    2014-01-01

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  7. MR-guided intervention in women with a family history of breast cancer

    International Nuclear Information System (INIS)

    Viehweg, P.; Bernerth, T.; Kiechle, M.; Buchmann, J.; Heinig, A.; Koelbl, H.; Laniado, M.; Heywang-Koebrunner, S.H.

    2006-01-01

    Objective: A study was undertaken to assess the clinical value of magnetic resonance (MR) imaging-guided interventions in women with a family history, but no personal history of breast cancer. Methods and patients: Retrospective review was performed on 63 consecutive women who had a family history, but no personal history of breast cancer. A total of 97 lesions were referred for an MR-guided intervention. Standardized MR examinations (1.0 T, T1-weighted 3D FLASH, 0.15 mmol Gd-DTPA/kg body weight, prone position) were performed using a dedicated system which allows vacuum assisted breast biopsy or wire localization. Results: Histologic findings in 87 procedures revealed 9 (10%) invasive carcinomas, 12 (14%) ductal carcinomas in situ, 2 atypical ductal hyperplasias (2.5%) and 2 atypical lobular hyperplasias (2.5%). Sixty-two (71%) benign histologic results are verified by an MR-guided intervention, retrospective correlation of imaging and histology and by subsequent follow-up. In ten lesions the indication dropped since the enhancing lesion was no longer visible. Absent enhancement was confirmed by short-term re-imaging of the noncompressed breast and by follow-up. Conclusion: Malignancy was found in 24%, high-risk lesions in 5% of successfully performed MR-guided biopsy procedures. A 57% of MR-detected malignancies were ductal carcinoma in situ. In 10% of the lesions the intervention was not performed, since no enhancing lesion could be reproduced at the date of anticipated intervention. Such problems may be avoided if the initial MRI is performed in the appropriate phase of the menstrual cycle and without hormonal replacement therapy

  8. MR-guided intervention in women with a family history of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Viehweg, P. [Institute of Diagnostic Radiology, Technical University Dresden, Fetscherstrasse 74, 01307 Dresden (Germany)]. E-mail: Petra.Viehweg@uniklinikum-dresden.de; Bernerth, T. [Department of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 16, 06097 Halle (Germany); Kiechle, M. [Department of Obstetrics and Gynaecology, Technical University Munich, Ismaninger Strasse 22, 81675 Munich (Germany); Buchmann, J. [Department of Pathology, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 14, 06097 Halle (Germany); Heinig, A. [Department of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 16, 06097 Halle (Germany); Koelbl, H. [Department of Obstetrics and Gynaecology, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 24, 06097 Halle (Germany); Laniado, M. [Institute of Diagnostic Radiology, Technical University Dresden, Fetscherstrasse 74, 01307 Dresden (Germany); Heywang-Koebrunner, S.H. [Department of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 16, 06097 Halle (Germany); Department of Diagnostic Radiology, Technical University Munich, Ismaninger Strasse 19, 81675 Munich (Germany)

    2006-01-15

    Objective: A study was undertaken to assess the clinical value of magnetic resonance (MR) imaging-guided interventions in women with a family history, but no personal history of breast cancer. Methods and patients: Retrospective review was performed on 63 consecutive women who had a family history, but no personal history of breast cancer. A total of 97 lesions were referred for an MR-guided intervention. Standardized MR examinations (1.0 T, T1-weighted 3D FLASH, 0.15 mmol Gd-DTPA/kg body weight, prone position) were performed using a dedicated system which allows vacuum assisted breast biopsy or wire localization. Results: Histologic findings in 87 procedures revealed 9 (10%) invasive carcinomas, 12 (14%) ductal carcinomas in situ, 2 atypical ductal hyperplasias (2.5%) and 2 atypical lobular hyperplasias (2.5%). Sixty-two (71%) benign histologic results are verified by an MR-guided intervention, retrospective correlation of imaging and histology and by subsequent follow-up. In ten lesions the indication dropped since the enhancing lesion was no longer visible. Absent enhancement was confirmed by short-term re-imaging of the noncompressed breast and by follow-up. Conclusion: Malignancy was found in 24%, high-risk lesions in 5% of successfully performed MR-guided biopsy procedures. A 57% of MR-detected malignancies were ductal carcinoma in situ. In 10% of the lesions the intervention was not performed, since no enhancing lesion could be reproduced at the date of anticipated intervention. Such problems may be avoided if the initial MRI is performed in the appropriate phase of the menstrual cycle and without hormonal replacement therapy.

  9. Navigation concepts for MR image-guided interventions.

    Science.gov (United States)

    Moche, Michael; Trampel, Robert; Kahn, Thomas; Busse, Harald

    2008-02-01

    The ongoing development of powerful magnetic resonance imaging techniques also allows for advanced possibilities to guide and control minimally invasive interventions. Various navigation concepts have been described for practically all regions of the body. The specific advantages and limitations of these concepts largely depend on the magnet design of the MR scanner and the interventional environment. Open MR scanners involve minimal patient transfer, which improves the interventional workflow and reduces the need for coregistration, ie, the mapping of spatial coordinates between imaging and intervention position. Most diagnostic scanners, in contrast, do not allow the physician to guide his instrument inside the magnet and, consequently, the patient needs to be moved out of the bore. Although adequate coregistration and navigation concepts for closed-bore scanners are technically more challenging, many developments are driven by the well-known capabilities of high-field systems and their better economic value. Advanced concepts such as multimodal overlays, augmented reality displays, and robotic assistance devices are still in their infancy but might propel the use of intraoperative navigation. The goal of this work is to give an update on MRI-based navigation and related techniques and to briefly discuss the clinical experience and limitations of some selected systems. (Copyright) 2008 Wiley-Liss, Inc.

  10. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer; MRT-gezielte interventionelle Verfahren zur Abklaerung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Division fuer Molekulare und Gender-Bildgebung, Wien (Austria); Margreiter, M. [Medizinische Universitaet Wien, Univ.-Klinik fuer Urologie, Wien (Austria)

    2011-11-15

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [German] Neben dem transrektalen Ultraschall (TRUS) hat sich in den letzten Jahren die MRT als nichtinvasive Methode zur Bildgebung von Prostatatumoren etabliert. Mittels T2-gewichteter Sequenzen ist eine exakte anatomische Darstellung der Prostata und ihrer umliegenden Strukturen moeglich. Andere MRT-Techniken ermoeglichen Rueckschluesse auf das biologische Verhalten des Tumors: dynamische kontrastmittelverstaerkte T1-gewichtete Sequenzen zur Darstellung der Angiogenese, diffusionsgewichtete Aufnahmen zur Beurteilung der Zelldichte und die Spektroskopie zur Bestimmung von Gewebemetaboliten wie Cholin und Kreatin (multiparametrische Bildgebung). Prostatatumoren, die nur mittels MRT nachweisbar sind oder verdaechtige Tumoren, die hauptsaechlich anterior in der Prostata lokalisiert sind und in wiederholten TRUS-gezielten Biopsien verfehlt wurden, benoetigen eine MRT-gezielte Biopsie zur Diagnosesicherung. Die bisherigen

  11. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  12. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  13. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  14. Dual optimization based prostate zonal segmentation in 3D MR images.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2014-05-01

    Efficient and accurate segmentation of the prostate and two of its clinically meaningful sub-regions: the central gland (CG) and peripheral zone (PZ), from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, a novel multi-region segmentation approach is proposed to simultaneously segment the prostate and its two major sub-regions from only a single 3D T2-weighted (T2w) MR image, which makes use of the prior spatial region consistency and incorporates a customized prostate appearance model into the segmentation task. The formulated challenging combinatorial optimization problem is solved by means of convex relaxation, for which a novel spatially continuous max-flow model is introduced as the dual optimization formulation to the studied convex relaxed optimization problem with region consistency constraints. The proposed continuous max-flow model derives an efficient duality-based algorithm that enjoys numerical advantages and can be easily implemented on GPUs. The proposed approach was validated using 18 3D prostate T2w MR images with a body-coil and 25 images with an endo-rectal coil. Experimental results demonstrate that the proposed method is capable of efficiently and accurately extracting both the prostate zones: CG and PZ, and the whole prostate gland from the input 3D prostate MR images, with a mean Dice similarity coefficient (DSC) of 89.3±3.2% for the whole gland (WG), 82.2±3.0% for the CG, and 69.1±6.9% for the PZ in 3D body-coil MR images; 89.2±3.3% for the WG, 83.0±2.4% for the CG, and 70.0±6.5% for the PZ in 3D endo-rectal coil MR images. In addition, the experiments of intra- and inter-observer variability introduced by user initialization indicate a good reproducibility of the proposed approach in terms of volume difference (VD) and coefficient-of-variation (CV) of DSC. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-13

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.

  16. Feasibility of a 2"n"d generation MR-compatible manipulator for transrectal prostate biopsy guidance

    International Nuclear Information System (INIS)

    Bomers, J.G.R.; Yakar, D.; Bosboom, D.G.H.; Tigelaar, G.H.; Sabisch, J.; Fuetterer, J.J.

    2017-01-01

    To assess the feasibility of a 2"n"d generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  17. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    Science.gov (United States)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  18. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  19. Feasibility of a 2{sup nd} generation MR-compatible manipulator for transrectal prostate biopsy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Bomers, J.G.R.; Yakar, D. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Bosboom, D.G.H. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Soteria Medical, Arnhem (Netherlands); Tigelaar, G.H.; Sabisch, J. [Soteria Medical, Arnhem (Netherlands); Fuetterer, J.J. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-04-15

    To assess the feasibility of a 2{sup nd} generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  20. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2011-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. PMID:21686038

  1. Integrated navigation and control software system for MRI-guided robotic prostate interventions.

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S; DiMaio, Simon P; Gobbi, David G; Csoma, Csaba; Mewes, Philip W; Fichtinger, Gabor; Tempany, Clare M; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called "workphases" that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. Integrated navigation and control software system for MRI-guided robotic prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S.; DiMaio, Simon P.; Gobbi, David G.; Csoma, Csaba; Mewes, Philip W.; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called “workphases” that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6 mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. PMID:19699057

  3. MR imaging of the prostate; MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Haas, M.; Hamm, B. [Charite Campus Benjamin Franklin, Klinik fuer Radiologie, Berlin (Germany)

    2015-12-15

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [German] Das Prostatakarzinom ist in Deutschland die haeufigste Krebserkrankung des Mannes, wobei ein deutlicher Unterschied zwischen Inzidenz und Mortalitaet besteht. Die Detektion des Prostatakarzinoms basiert auf klinischer und laborchemischer Untersuchung (prostataspezifisches-Antigen[PSA]-Wert) sowie der transrektalen Ultraschalluntersuchung mit randomisierter Biopsie. Die multiparametrische MR-Tomographie kann zur Detektion des Prostatakarzinoms, insbesondere bei negativer Biopsie vor einer erneuten Biopsie wertvolle diagnostische Informationen liefern. Zudem wird zunehmend die MRT-Ultraschall-Fusionsbiopsie in der Diagnostik eingesetzt, wodurch die Detektionsrate des Prostatakarzinoms deutlich gesteigert werden kann. Mit Einfuehrung der PI-RADS-Klassifikation (Prostate Imaging-Reporting and Data System) konnte zudem eine Standardisierung der Befundung erreicht werden, was die Akzeptanz der MRT der Prostata in der Urologie erhoeht hat. (orig.)

  4. Deformable MR Prostate Segmentation via Deep Feature Learning and Sparse Patch Matching.

    Science.gov (United States)

    Guo, Yanrong; Gao, Yaozong; Shen, Dinggang

    2016-04-01

    Automatic and reliable segmentation of the prostate is an important but difficult task for various clinical applications such as prostate cancer radiotherapy. The main challenges for accurate MR prostate localization lie in two aspects: (1) inhomogeneous and inconsistent appearance around prostate boundary, and (2) the large shape variation across different patients. To tackle these two problems, we propose a new deformable MR prostate segmentation method by unifying deep feature learning with the sparse patch matching. First, instead of directly using handcrafted features, we propose to learn the latent feature representation from prostate MR images by the stacked sparse auto-encoder (SSAE). Since the deep learning algorithm learns the feature hierarchy from the data, the learned features are often more concise and effective than the handcrafted features in describing the underlying data. To improve the discriminability of learned features, we further refine the feature representation in a supervised fashion. Second, based on the learned features, a sparse patch matching method is proposed to infer a prostate likelihood map by transferring the prostate labels from multiple atlases to the new prostate MR image. Finally, a deformable segmentation is used to integrate a sparse shape model with the prostate likelihood map for achieving the final segmentation. The proposed method has been extensively evaluated on the dataset that contains 66 T2-wighted prostate MR images. Experimental results show that the deep-learned features are more effective than the handcrafted features in guiding MR prostate segmentation. Moreover, our method shows superior performance than other state-of-the-art segmentation methods.

  5. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  6. An MR-compatible stereoscopic in-room 3D display for MR-guided interventions.

    Science.gov (United States)

    Brunner, Alexander; Groebner, Jens; Umathum, Reiner; Maier, Florian; Semmler, Wolfhard; Bock, Michael

    2014-08-01

    A commercial three-dimensional (3D) monitor was modified for use inside the scanner room to provide stereoscopic real-time visualization during magnetic resonance (MR)-guided interventions, and tested in a catheter-tracking phantom experiment at 1.5 T. Brightness, uniformity, radio frequency (RF) emissions and MR image interferences were measured. Due to modifications, the center luminance of the 3D monitor was reduced by 14%, and the addition of a Faraday shield further reduced the remaining luminance by 31%. RF emissions could be effectively shielded; only a minor signal-to-noise ratio (SNR) decrease of 4.6% was observed during imaging. During the tracking experiment, the 3D orientation of the catheter and vessel structures in the phantom could be visualized stereoscopically.

  7. Prostatic carcinoma. Diagnostic and stating: MR imaging. Cancer de la prostate Diagnostic et bilan: role de l'imagerie

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C; Spittler, G; Jacqmin, D [Centre Hospitalier Universitaire, 67 - Strasbourg (FR); Morel, M [Clinique Saint-Francois, 67 Haguenau (FR)

    1991-01-01

    Prostatic carcinoma is the second most commun cause of cancer death over 60 years. It is suspected by digital examination and prostatic specific antigen dosage. Transrectal ultrasound shows the tumor as an hypoechoic lesion. Sensitivity is good but specificity is low. Transrectal biopsy of prostate guided by transrectal ultrasound made the diagnosis. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging of prostatic carcinoma.

  8. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  9. Prostatic MR imaging. Accuracy in differentiating cancer from other prostatic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ikonen, S.; Kivisaari, L.; Tervahartiala, P. [Helsinki Univ. Central Hospital (Finland). Dept of Radiology; Vehmas, T. [Finnish Inst. of Occupational Health, Helsinki (Finland); Taari, K.; Rannikko, S. [Helsinki Univ. Central Hospital (Finland). Dept of Urology

    2001-03-01

    Purpose: We assessed the accuracy of MR imaging in differentiating between cancer and other prostatic disorders, and evaluated the diagnostic criteria for various prostatic diseases. Material and Methods: A total of 74 endorectal coil MR studies were performed on 72 patients. Twenty patients had prostatic cancer, 20 benign prostatic hyperplasia (BPH), 4 acute bacterial prostatitis, 5 chronic bacterial prostatitis (2 also belonging to the previous category), 19 chronic non-bacterial prostatitis/chronic pelvic pain syndrome, and 6 were symptomless voluntary controls. All studies were interpreted by two experienced radiologists in random order. Radiologists were blinded to all clinical data including the age of the patients. Based on MR findings, both radiologists filled in a form covering diagnostic criteria and diagnosis. Results: Accuracy in diagnosing prostate cancer was 74%. Sensitivity was 50% and specificity 83%, and positive and negative predictive values were 53 and 82%, respectively. Bacterial prostatitis showed some features similar to carcinoma. Abundant BPH rendered cancer detection more difficult. No diagnostic criterion was clearly better than the others. Interobserver agreement on the MR diagnosis ranged from moderate to good. Conclusion: Without knowledge of accurate clinical data, MR seems to be too insensitive in detecting prostate cancer to be used as a primary diagnostic tool.

  10. MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment

    International Nuclear Information System (INIS)

    Mu Zhaomei; Ma, C-M; Chen Xiaoming; Cvetkovic, Dusica; Chen Lili; Pollack, Alan

    2012-01-01

    The purpose of this study is to evaluate the efficacy of the enhancement of docetaxel by pulsed focused ultrasound (pFUS) in combination with radiotherapy (RT) for treatment of prostate cancer in vivo. LNCaP cells were grown in the prostates of male nude mice. When the tumors reached a designated volume by MRI, tumor bearing mice were randomly divided into seven groups (n = 5): (1) pFUS alone; (2) RT alone; (3) docetaxel alone; (4) docetaxel + pFUS; (5) docetaxel + RT; (6) docetaxel + pFUS + RT, and (7) control. MR-guided pFUS treatment was performed using a focused ultrasound treatment system (InSightec ExAblate 2000) with a 1.5T GE MR scanner. Animals were treated once with pFUS, docetaxel, RT or their combinations. Docetaxel was given by i.v. injection at 5 mg kg −1 before pFUS. RT was given 2 Gy after pFUS. Animals were euthanized 4 weeks after treatment. Tumor volumes were measured on MRI at 1 and 4 weeks post-treatment. Results showed that triple combination therapies of docetaxel, pFUS and RT provided the most significant tumor growth inhibition among all groups, which may have potential for the treatment of prostate cancer due to an improved therapeutic ratio. (paper)

  11. MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment

    Science.gov (United States)

    Mu, Zhaomei; Ma, C.-M.; Chen, Xiaoming; Cvetkovic, Dusica; Pollack, Alan; Chen, Lili

    2012-01-01

    The purpose of this study is to evaluate the efficacy of the enhancement of docetaxel by pulsed focused ultrasound (pFUS) in combination with radiotherapy (RT) for treatment of prostate cancer in vivo. LNCaP cells were grown in the prostates of male nude mice. When the tumors reached a designated volume by MRI, tumor bearing mice were randomly divided into seven groups (n = 5): (1) pFUS alone; (2) RT alone; (3) docetaxel alone; (4) docetaxel + pFUS (5) docetaxel + RT (6) docetaxel + pFUS + RT, and (7) control. MR-guided pFUS treatment was performed using a focused ultrasound treatment system (InSightec ExAblate 2000) with a 1.5T GE MR scanner. Animals were treated once with pFUS, docetaxel, RT or their combinations. Docetaxel was given by i.v. injection at 5 mg kg-1 before pFUS. RT was given 2 Gy after pFUS. Animals were euthanized 4 weeks after treatment. Tumor volumes were measured on MRI at 1 and 4 weeks post-treatment. Results showed that triple combination therapies of docetaxel, pFUS and RT provided the most significant tumor growth inhibition among all groups, which may have potential for the treatment of prostate cancer due to an improved therapeutic ratio.

  12. Proton MR spectroscopy of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, Ullrich G. [Dept. of Clinical Radiology, Klinikum der Universitaet Muenchen, Standorte Grosshadern und Innenstadt, Ziemssenstrasse 1, D-80336 Munich (Germany)], E-mail: ullrich.mueller-lisse@med.uni-muenchen.de; Scherr, Michael K. [Dept. of Clinical Radiology, Klinikum der Universitaet Muenchen, Standorte Grosshadern und Innenstadt, Ziemssenstrasse 1, D-80336 Munich (Germany)

    2007-09-15

    Purpose: To summarize current technical and biochemical aspects and clinical applications of proton magnetic resonance spectroscopy (MRS) of the human prostate in vivo. Material and methods: Pertinent radiological and biochemical literature was searched and retrieved via electronic media (medline, pubmed). Basic concepts of MRS of the prostate and its clinical applications were extracted. Results: Clinical MRS is usually based on point resolved spectroscopy (PRESS) or spin echo (SE) sequences, along with outer volume suppression of signals from outside of the prostate. MRS of the prostate detects indicator lines of citrate, choline, and creatine. While healthy prostate tissue demonstrates high levels of citrate and low levels of choline that marks cell wall turnover, prostate cancer utilizes citrate for energy metabolism and shows high levels of choline. The ratio of (choline + creatine)/citrate distinguishes between healthy tissue and prostate cancer. Particularly when combined with magnetic resonance (MR) imaging, three-dimensional MRS imaging (3D-CSI, or 3D-MRSI) detects and localizes prostate cancer in the entire prostate with high sensitivity and specificity. Combined MR imaging and 3D-MRSI exceed the sensitivity and specificity of sextant biopsy of the prostate. When MRS and MR imaging agree on prostate cancer presence, the positive predictive value is about 80-90%. Distinction between healthy tissue and prostate cancer principally is maintained after various therapeutic treatments, including hormone ablation therapy, radiation therapy, and cryotherapy of the prostate. Conclusions: Since it is non-invasive, reliable, radiation-free, and essentially repeatable, combined MR imaging and 3D-MRSI of the prostate lends itself to the planning of biopsy and therapy, and to post-therapeutic follow-up. For broad clinical acceptance, it will be necessary to facilitate MRS examinations and their evaluation and make MRS available to a wider range of institutions.

  13. Building a high-resolution T2-weighted MR-based probabilistic model of tumor occurrence in the prostate.

    Science.gov (United States)

    Nagarajan, Mahesh B; Raman, Steven S; Lo, Pechin; Lin, Wei-Chan; Khoshnoodi, Pooria; Sayre, James W; Ramakrishna, Bharath; Ahuja, Preeti; Huang, Jiaoti; Margolis, Daniel J A; Lu, David S K; Reiter, Robert E; Goldin, Jonathan G; Brown, Matthew S; Enzmann, Dieter R

    2018-02-19

    We present a method for generating a T2 MR-based probabilistic model of tumor occurrence in the prostate to guide the selection of anatomical sites for targeted biopsies and serve as a diagnostic tool to aid radiological evaluation of prostate cancer. In our study, the prostate and any radiological findings within were segmented retrospectively on 3D T2-weighted MR images of 266 subjects who underwent radical prostatectomy. Subsequent histopathological analysis determined both the ground truth and the Gleason grade of the tumors. A randomly chosen subset of 19 subjects was used to generate a multi-subject-derived prostate template. Subsequently, a cascading registration algorithm involving both affine and non-rigid B-spline transforms was used to register the prostate of every subject to the template. Corresponding transformation of radiological findings yielded a population-based probabilistic model of tumor occurrence. The quality of our probabilistic model building approach was statistically evaluated by measuring the proportion of correct placements of tumors in the prostate template, i.e., the number of tumors that maintained their anatomical location within the prostate after their transformation into the prostate template space. Probabilistic model built with tumors deemed clinically significant demonstrated a heterogeneous distribution of tumors, with higher likelihood of tumor occurrence at the mid-gland anterior transition zone and the base-to-mid-gland posterior peripheral zones. Of 250 MR lesions analyzed, 248 maintained their original anatomical location with respect to the prostate zones after transformation to the prostate. We present a robust method for generating a probabilistic model of tumor occurrence in the prostate that could aid clinical decision making, such as selection of anatomical sites for MR-guided prostate biopsies.

  14. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    Science.gov (United States)

    2009-09-01

    ultrasound . J. Acoust. Soc.Am. 72 1926-1932, (1982) (7) Neppiras E A. Acoustic cavitation . Physics reports 61(3): 159-251, (1980) (8) ter Haar G R, Daniels...Guided Pulsed High-Intensity Focused Ultrasound Enhancement of 5b. GRANT NUMBER W81XWH-08-1-0469 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...failing to This work is aimed to study MR guided high intensity focused ultrasound (MRgHIFU) enhancement of gene therapy for Prostate Cancer. The

  15. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy

    Science.gov (United States)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2014-01-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm. PMID:25076821

  16. MRI-guided robot for needle interventions in the prostate

    NARCIS (Netherlands)

    van den Bosch, M.R.

    2011-01-01

    Magnetic resonance imaging (MRI) is applied to non-invasively visualize patient’s anatomy and tumour suspicious regions with superior soft tissue contrast. Amongst others, online MRI is valuable in the diagnostic and treatment techniques for prostate cancer. Clinical MR scanners are suitable to

  17. MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A.; Mueller-Lisse, U.G.; Massmann, J.

    2003-01-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [de

  18. Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

    Science.gov (United States)

    Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A

    2014-02-01

    To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.

  19. Introduction of a MR-compatible system for extracorporal perfusion of vital organs for MR-guided procedures. First-experiences

    International Nuclear Information System (INIS)

    Gaffke, Gunnar; Nagel, Stefan; Hegemann, Olaf; Speck, Ulrich; Grosse-Siestrup, Christian; Jungnickel, Kerstin; Stroszczynski, Christian

    2009-01-01

    Purpose:To represent a MRI-compatible perfusion-system for extracorporeal perfusion of vital organs which permits the realisation of realistic experiments in a MR scanner. Material and methods: We performed MR examinations of explanted porcine livers and MR-guided interventions in porcine livers. Explanted organs were hemo-perfused under physiological conditions during the experiments. MR-sequences for diagnostic and interventional examinations were used. Results:The evaluated system was MRI-compatible. The achieved image quality of the used sequences showed excellent anatomical resolution. Planned experiments can be carried out with relatively low expenditure. Diagnostic as well as interventional investigations can be carried out. The used organs showed a stable function within physiological parameters up to 4 hours. Conclusion:It is possible to perform ex vivo experiments under in vivo conditions with this system. With the used MR-compatible system MR-guided experimental interventions and thermal ablations can be carried out in explanted organs under in vivo conditions. (orig.)

  20. Comparison of manual and automatic MR-CT registration for radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Riis Østergaard, Lasse

    2016-05-08

    In image-guided radiotherapy (IGRT) of prostate cancer, delineation of the clini-cal target volume (CTV) often relies on magnetic resonance (MR) because of its good soft-tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR-CT registration of the prostate has previously been developed using a voxel property-based registration as an alternative to a manual landmark-based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni-Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration.

  1. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

    Science.gov (United States)

    Salgaonkar, Vasant A.; Prakash, Punit; Rieke, Viola; Ozhinsky, Eugene; Plata, Juan; Kurhanewicz, John; Hsu, I.-C. Joe; Diederich, Chris J.

    2017-03-01

    Here, operational modifications to a commercial MR-guided ultrasound phased array designed for prostate ablation (part of ExAblate 2100, InSightec Ltd) are presented for the delivery of protracted mild (40 - 45°C) hyperthermia to large contiguous target volumes in the prostate. This high-intensity focused ultrasound phased array is already in clinical trials for prostate ablation, and can be potentially fast-tracked for clinical hyperthermia treatments. As a part of this preliminary feasibility study, patient-specific numerical simulations were performed using Pennes bioheat model and acoustic field calculations were conducted using the rectangular radiator method for the ExAblate prostate array (2.3 MHz, 2.3×4.0 cm2, ˜1000 channels). Thermal solutions were computed using 3D finite element methods (FEM) implemented using Comsol Multiphysics (Comsol Inc). The patient-specific geometries were created through manual segmentation of anatomical structures from representative patient MRIs and 3D rendering (Mimics 15.01, Materialise) and generation of finite element meshes (3-Matic 7.01, Materialise). Array beamforming was employed and acoustic fields were synthesized (Matlab 2010a, MathWorks) to deliver protracted continuous wave hyperthermia to focal prostate cancer targets identified in the patient-specific models. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Sonication strategies explored during modeling were implemented on the ExAblate prostate array and preliminary experiments were conducted in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Therapeutic temperatures (40 - 45 °C) could be established conformably in focal cancer volumes in a single prostate quadrant using focused heating patterns and hemi-gland heating was possible using diffused heating patterns (iso-phase or diverging). T>41 °C was calculated in 13

  2. A MR-conditional High-torque Pneumatic Stepper Motor for MRI-guided and Robot-assisted Intervention

    Science.gov (United States)

    Chen, Yue; Kwok, Ka-Wai; Tse, Zion Tsz Ho

    2015-01-01

    Magnetic Resonance Imaging allows for visualizing detailed pathological and morphological changes of soft tissue. This increasingly attracts attention on MRI-guided intervention; hence, MR-conditional actuations have been widely investigated for development of image-guided and robot-assisted surgical devices under the MRI. This paper presents a simple design of MR-conditional stepper motor which can provide precise and high-torque actuation without adversely affecting the MR image quality. This stepper motor consists of two MR-conditional pneumatic cylinders and the corresponding supporting structures. Alternating the pressurized air can drive the motor to rotate each step in 3.6° with the motor coupled to a planetary gearbox. Experimental studies were conducted to validate its dynamics performance. Maximum 800mNm output torque can be achieved. The motor accuracy independently varied by two factors: motor operating speed and step size, was also investigated. The motor was tested within a Siemens 3T MRI scanner. The image artifact and the signal-to-noise ratio (SNR) were evaluated in order to study its MRI compliancy. The results show that the presented pneumatic stepper motor generated 2.35% SNR reduction in MR images and no observable artifact was presented besides the motor body itself. The proposed motor test also demonstrates a standard to evaluate the motor capability for later incorporation with motorized devices used in robot-assisted surgery under MRI. PMID:24957635

  3. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  4. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer.

    Science.gov (United States)

    Bates, Anthony; Miles, Kenneth

    2017-12-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at prostate cancer. • Prostate transition zone (TZ) MR texture analysis may assist in prostate cancer detection. • Abnormal transition zone PSMA expression correlates with altered texture on T2-weighted MR. • TZ with abnormal PSMA expression demonstrates significantly reduced MI, SD and MPP.

  5. MR-guided focused ultrasound: a potentially disruptive technology.

    Science.gov (United States)

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  6. Clinical use of MR imaging-guided interventions; Klinischer Einsatz der interventionellen MRT (iMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, T.; Schulz, T.; Moche, M.; Prothmann, S.; Schneider, J.P. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany)

    2003-07-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures. (orig.) [German] Die Integration diagnostischer und therapeutischer Massnahmen durch die MRT basiert auf der Kombination von exzellenter morphologischer und funktioneller Bildgebung. Das Spektrum MR-gefuehrter Eingriffe reicht von Biopsien, thermischen Therapieverfahren, vaskulaeren Applikationen bis hin zum intraoperativen Einsatz der MRT. Auf allen Gebieten konnten von verschiedenen Arbeitsgruppen ueberzeugende Ergebnisse sowohl im Bereich der Grundlagenentwicklung als auch bei klinischen Anwendungen vorgelegt werden. Es ist davon auszugehen, dass die interventionelle MRT einen hohen Stellenwert im Bereich der interventionellen Radiologie, der minimal-invasiven Therapie und der Ueberwachung von operativen Eingriffen erlangen wird. (orig.)

  7. MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer.

    Science.gov (United States)

    Scherr, M K; Seitz, M; Müller-Lisse, U G; Ingrisch, M; Reiser, M F; Müller-Lisse, U L

    2010-12-01

    Various MR methods, including MR-spectroscopy (MRS), dynamic, contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI) have been applied to improve test quality of standard MRI of the prostate. To determine if quantitative, model-based MR-perfusion (MRP) with gadobenate dimeglumine (Gd-BOPTA) discriminates between prostate cancer, benign tissue, and transitional zone (TZ) tissue. 27 patients (age, 65±4 years; PSA 11.0±6.1 ng/ml) with clinical suspicion of prostate cancer underwent standard MRI, 3D MR-spectroscopy (MRS), and MRP with Gd-BOPTA. Based on results of combined MRI/MRS and subsequent guided prostate biopsy alone (17/27), biopsy and radical prostatectomy (9/27), or sufficient negative follow-up (7/27), maps of model-free, deconvolution-based mean transit time (dMTT) were generated for 29 benign regions (bROIs), 14 cancer regions (cROIs), and 18 regions of transitional zone (tzROIs). Applying a 2-compartment exchange model, quantitative perfusion analysis was performed including as parameters: plasma flow (PF), plasma volume (PV), plasma mean transit time (PMTT), extraction flow (EFL), extraction fraction (EFR), interstitial volume (IV) and interstitial mean transit time (IMTT). Two-sided T-tests (significance level pMRP with Gd-BOPTA discriminates between prostate cancer and benign tissue with several parameters. However, distinction of prostate cancer and TZ does not appear to be reliable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. MR-guided pain therapy: principles and clinical applications; MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Pereira, P.L. [Diagnostische Radiologie, Eberhard-Karls-Universitaet, Tuebingen (Germany)

    2007-09-15

    X-ray fluoroscopy and computed tomography are frequently used to perform percutaneous interventions in pain therapy. The development of MR-compatible therapy needles now allows these interventions to be performed under MR imaging guidance. MR-guided interventions may be performed using most clinical MR scanners; however, systems with an open configuration are advantageous. Multiplanar pre- and intra-procedural MR imaging provides the interventionalist with essential information, such as evaluation of anatomy and pathology, as well as the planning of the procedure and monitoring of fluid distribution without the use of contrast agents. With the use of non-ionizing radiation, interventional MR imaging is especially suited for the treatment of children and young adults as well as for serial injection therapy. For spinal MR interventions, passive needle visualization is an easily achievable and reliable method. The resulting needle artifact is influenced by several factors such as the alloy of the needle, the strength of the static magnetic field, the sequence type, the spatial orientation of the therapy needle as well as the echo time and may further be optimized during the intervention by alteration of the last three factors. Fast acquisition techniques and image processing allow for continuous, near real-time MR imaging (so-called MR fluoroscopy) and interactive needle navigations, comparable to X-ray fluoroscopy and CT fluoroscopy. The purpose of this review is to illustrate and discuss general concepts of interventional MR imaging. A spectrum of interventional MR imaging procedures in spinal pain therapy is described and illustrated, including procedures such as lumbar facet joint injections, sacroiliac joint injections, lumbar spinal nerve root infiltrations and drug delivery to the lumbar sympathetic chain. (orig.)

  9. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning.

    Science.gov (United States)

    Guo, Yanrong; Gao, Yaozong; Shao, Yeqin; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-07-01

    Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the

  10. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    Science.gov (United States)

    Guo, Yanrong; Gao, Yaozong; Shao, Yeqin; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-01-01

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different

  11. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    International Nuclear Information System (INIS)

    Guo, Yanrong; Shao, Yeqin; Gao, Yaozong; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-01-01

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on

  12. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yanrong; Shao, Yeqin [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Price, True [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 and Department of Computer Science, University of North Carolina at Chapel Hill, North Carolina 27599 (United States); Oto, Aytekin [Department of Radiology, Section of Urology, University of Chicago, Illinois 60637 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2014-07-15

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on

  13. Clinical stage T1c prostate cancer: evaluation with endorectal MR imaging and MR spectroscopic imaging.

    Science.gov (United States)

    Zhang, Jingbo; Hricak, Hedvig; Shukla-Dave, Amita; Akin, Oguz; Ishill, Nicole M; Carlino, Lauren J; Reuter, Victor E; Eastham, James A

    2009-11-01

    To assess the diagnostic accuracy of endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for prediction of the pathologic stage of prostate cancer and the presence of clinically nonimportant disease in patients with clinical stage T1c prostate cancer. The institutional review board approved-and waived the informed patient consent requirement for-this HIPAA-compliant study involving 158 patients (median age, 58 years; age range, 40-76 years) who had clinical stage T1c prostate cancer, had not been treated preoperatively, and underwent combined 1.5-T endorectal MR imaging-MR spectroscopic imaging between January 2003 and March 2004 before undergoing radical prostatectomy. On the MR images and combined endorectal MR-MR spectroscopic images, two radiologists retrospectively and independently rated the likelihood of cancer in 12 prostate regions and the likelihoods of extracapsular extension (ECE), seminal vesicle invasion (SVI), and adjacent organ invasion by using a five-point scale, and they determined the probability of clinically nonimportant prostate cancer by using a four-point scale. Whole-mount step-section pathology maps were used for imaging-pathologic analysis correlation. Receiver operating characteristic curves were constructed and areas under the curves (AUCs) were estimated nonparametrically for assessment of reader accuracy. At surgical-pathologic analysis, one (0.6%) patient had no cancer; 124 (78%) patients, organ-confined (stage pT2) disease; 29 (18%) patients, ECE (stage pT3a); two (1%) patients, SVI (stage pT3b); and two (1%) patients, bladder neck invasion (stage pT4). Forty-six (29%) patients had a total tumor volume of less than 0.5 cm(3). With combined MR imaging-MR spectroscopic imaging, the two readers achieved 80% accuracy in disease staging and AUCs of 0.62 and 0.71 for the prediction of clinically nonimportant cancer. Clinical stage T1c prostate cancers are heterogeneous in pathologic stage and volume. MR imaging may

  14. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  15. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  16. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  17. SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Assarian Cancer Center, Novi, MI (United States); University of Michigan, Ann Arbor, MI (United States); Yao, B [Assarian Cancer Center, Novi, MI (United States)

    2016-06-15

    Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mm expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.

  18. [Clinical use of interventional MR imaging].

    Science.gov (United States)

    Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter

    2003-01-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.

  19. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  20. TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T [Emory University, Atlanta, GA (United States)

    2016-06-15

    Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be

  1. TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

    International Nuclear Information System (INIS)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T

    2016-01-01

    Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be

  2. MR PROSTATE SEGMENTATION VIA DISTRIBUTED DISCRIMINATIVE DICTIONARY (DDD) LEARNING.

    Science.gov (United States)

    Guo, Yanrong; Zhan, Yiqiang; Gao, Yaozong; Jiang, Jianguo; Shen, Dinggang

    2013-01-01

    Segmenting prostate from MR images is important yet challenging. Due to non-Gaussian distribution of prostate appearances in MR images, the popular active appearance model (AAM) has its limited performance. Although the newly developed sparse dictionary learning method[1, 2] can model the image appearance in a non-parametric fashion, the learned dictionaries still lack the discriminative power between prostate and non-prostate tissues, which is critical for accurate prostate segmentation. In this paper, we propose to integrate deformable model with a novel learning scheme, namely the Distributed Discriminative Dictionary ( DDD ) learning, which can capture image appearance in a non-parametric and discriminative fashion. In particular, three strategies are designed to boost the tissue discriminative power of DDD. First , minimum Redundancy Maximum Relevance (mRMR) feature selection is performed to constrain the dictionary learning in a discriminative feature space. Second , linear discriminant analysis (LDA) is employed to assemble residuals from different dictionaries for optimal separation between prostate and non-prostate tissues. Third , instead of learning the global dictionaries, we learn a set of local dictionaries for the local regions (each with small appearance variations) along prostate boundary, thus achieving better tissue differentiation locally. In the application stage, DDDs will provide the appearance cues to robustly drive the deformable model onto the prostate boundary. Experiments on 50 MR prostate images show that our method can yield a Dice Ratio of 88% compared to the manual segmentations, and have 7% improvement over the conventional AAM.

  3. Multiparametric MR imaging in diagnosis of chronic prostatitis and its differentiation from prostate cancer

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Sah

    2015-03-01

    Full Text Available Chronic prostatitis is a heterogeneous condition with high prevalence rate. Chronic prostatitis has overlap in clinical presentation with other prostate disorders and is one of the causes of high serum prostate specific antigen (PSA level. Chronic prostatitis, unlike acute prostatitis, is difficult to diagnose reliably and accurately on the clinical grounds alone. Not only this, it is also challenging to differentiate chronic prostatitis from prostate cancer with imaging modalities like TRUS and conventional MR Imaging, as the findings can mimic those of prostate cancer. Even biopsy doesn't play promising role in the diagnosis of chronic prostatitis as it has limited sensitivity and specificity. As a result of this, chronic prostatitis may be misdiagnosed as a malignant condition and end up in aggressive surgical management resulting in increased morbidity. This warrants the need of reliable diagnostic tool which has ability not only to diagnose it reliably but also to differentiate it from the prostate cancer. Recently, it is suggested that multiparametric MR Imaging of the prostate could improve the diagnostic accuracy of the prostate cancer. This review is based on the critically published literature and aims to provide an overview of multiparamateric MRI techniques in the diagnosis of chronic prostatitis and its differentiation from prostate cancer.

  4. Should abdominal sequences be included in prostate cancer MR staging studies?

    International Nuclear Information System (INIS)

    McEvoy, S.H.; Lavelle, L.P.; Purcell, Y.M.; Quinlan, D.M.; Skehan, S.J.; Collins, C.D.; McMahon, C.J.

    2015-01-01

    Highlights: • ESUR guideline that abdominal MR sequences are reserved for high-risk prostate cancer is tested. • Routine abdominal sequences are of low yield in prostate cancer MR staging. • Routine abdominal staging sequences frequently result in incidental findings. • Abdominal staging sequences should be reserved for high-risk prostate cancer cases. - Abstract: Objectives: Prostate cancer staging MR examinations commonly include abdominal sequences to assess for non-regional (common iliac or para-aortic) nodal metastasis. In our experience the diagnostic yield of this is limited, but incidental findings are frequent, often necessitating further investigations. The aim of this study is to assess the diagnostic utility of abdominal sequences in routine prostate cancer MR staging studies. Methods: Findings on abdominal sequences of consecutive MRI prostate studies performed for staging newly diagnosed prostate cancer between September 2011 and September 2013 were reviewed with respect to adenopathy and additional incidental findings. Results were correlated with Gleason grade and serum prostate-specific antigen (PSA) level in each case. Results: 355 MRI prostate examinations were reviewed. 4 (1.1%) showed enlarged non-regional lymph nodes. Incidental findings were found in 82(23.1%) cases, neccessitating further investigation in 45 (12.7%) cases. Enlarged non-regional nodes were associated with higher PSA level and Gleason grade (p = 0.007, p = 0.005 respectively). With a combined threshold of PSA > 20 ng/mL and/or Gleason grade ≥8 the sensitivity, specificity, PPV and NPV were 100, 60, 3 and 100% respectively for predicting the presence of non-regional adenopathy. Conclusions: Routine abdominal sequences are of very low yield in routine prostate cancer MR staging, frequently resulting in incidental findings requiring further work-up and should be reserved for high-risk cases. Our experience supports the use of an abdominal staging sequence in high

  5. MR-guided lumbar sympathicolysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H. [Department of Diagnostic Radiology, University of Tuebingen (Germany); Schneider, Wilke [Department of Vascular Surgery, University of Tuebingen (Germany)

    2002-06-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  6. MR-guided lumbar sympathicolysis

    International Nuclear Information System (INIS)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H.; Schneider, Wilke

    2002-01-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  7. Endorectal coil MRI and MR-spectroscopic imaging in patients with elevated serum prostate specific antigen with negative trus transrectal ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Farooq Ahmad Ganie

    2013-01-01

    Conclusion: Prostatic biopsy directed with endorectal coil MRI and MR-spectroscopic imaging findings in patients with elevated serum PSA and prior negative biopsy, improves the early diagnosis of prostatic carcinoma and accurate localization of prostate cancer within the gland.

  8. Value of MR-guided localization and biopsy in breast lesions; Stellenwert der MR-gestuetzten Lokalisation und Biopsie von Brustlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Grabbe, E.; Knollmann, F. [Abt. Diagnostische Radiologie, Georg-August-Univ. Goettingen (Germany)

    2006-05-15

    Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i.e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guide intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature. (orig.)

  9. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  10. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  11. The clinical value of MR elastography in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Chen Min; Li Saying; Wang Wenchao; Zhao Weifeng; Yang Zhenghan; Liu Ming; Zhou Cheng

    2010-01-01

    Objective: To investigate the clinical value of MR elastography in the diagnosis of prostate cancer at 3.0 T, and to assess the elasticity and viscosity of prostate cancer and benign prostatic diseases. Methods: Eight patients (63±7 years old) with 12 foci of prostate cancer and 10 patients (59±3 years old) with 14 foci of prostatitis in the peripheral zone were evaluated by MR elastography. MR elastography was performed by transmitting low-frequency longitudinal mechanical waves of 100 Hz into prostate with a transducer placed above the pubic bones. The phase images were reconstructed to acquire viscoelastic mapping. t test was used to compare the mean elasticity and viscosity of prostate cancer and prostatitis. The correlation of elasticity and Gleason scores between prostate cancer and prostatitis were also retrospectively analyzed with Pearson Correlation. Results: The mean elasticity and viscosity were significantly higher in prostate cancer [(6.55±0.47) kPa, (6.56±0.99) Pa·s, respectively] than in prostatitis [(1.99±0.66) kPa, (2.13±0.21) Pa·s, respectively], and the difference was statistically significant (t=19.392, 16.372; P<0.01). In 8 patients with prostate cancer, the Gleason scores were 5 (2 cases), 6 (3 cases), 7 (2 cases) and 8 (1 case), respectively. The mean elasticity for the cases with different Gleason scores was 5.83, 6.02, 7.45 and 8.05 kPa, respectively. There was a positive correlation between Gleason scores and elasticity of the prostate cancer(r=0.913, P<0.01) in this study. Conclusion: MR elastography can be used to visualize the difference in stiffness between prostate cancer and benign prostatic disease, it is a new imaging method with great potential in grading of prostate cancer. (authors)

  12. Prostate cancer: a comparative study of {sup 11}C-choline PET and MR imaging combined with proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Takako; Lee, Jin; Takahashi, Nobukazu; Oka, Takashi; Shizukuishi, Kazuya; Inoue, Tomio [Yokohama City University School of Medicine, Department of Radiology, Yokohama (Japan); Uemura, Hiroji; Kubota, Yoshinobu [Yokohama City University School of Medicine, Department of Urology, Kanagawa (Japan); Sasaki, Takeshi [Yokohama City University School of Medicine, Department of Pathology, Kanagawa (Japan); Endou, Hisashi [Yokohama City University School of Medicine, Department of Pharmacy, Kanagawa (Japan)

    2005-07-01

    Prostate cancer is difficult to visualise in its early stages using current imaging technology. The present study aimed to clarify the utility of {sup 11}C-choline PET for localising and evaluating cancer lesions in patients with prostate cancer by conducting a prospective comparison with magnetic resonance (MR) imaging combined with proton MR spectroscopy. PET and MR imaging combined with proton MR spectroscopy were performed in 20 patients with prostate cancer. Correlations among the metabolite ratio of choline + creatine to citrate (Cho+Cr/Ci) on MR spectroscopy, serum PSA and maximum standardised uptake value (SUV{sub max}) of {sup 11}C-choline were assessed. The location of the primary lesion was assessed by the site of SUV{sub max} and the laterality of the highest Cho+Cr/Ci ratio and confirmed by examination of surgical pathology specimens (n=16). PET exhibited a diagnostic sensitivity of 100% (20/20) for primary lesions, while the sensitivities of MR imaging and MR spectroscopy were 60% (12/20) and 65% (13/20), respectively. Weak linear correlations were observed between SUV{sub max} and serum PSA (r=0.52, p<0.05), and between SUV{sub max} and Cho+Cr/Ci ratio (r=0.49, p<0.05). Regarding the localisation of main primary lesions, PET results agreed with pathological findings in 13 patients (81%) ({kappa}=0.59), while MR spectroscopy results were in accordance with pathological findings in eight patients (50%) ({kappa}=0.11). This preliminary study suggests that {sup 11}C-choline PET may provide more accurate information regarding the localisation of main primary prostate cancer lesions than MR imaging/MR spectroscopy. A further clinical study of {sup 11}C-choline PET in a large number of patients suspected of prostate cancer will be necessary to determine the clinical utility of {sup 11}C-choline PET in patients who clinically require biopsy. (orig.)

  13. Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon

    International Nuclear Information System (INIS)

    Jones, Bernard L.; Gan, Gregory; Diot, Quentin; Kavanagh, Brian; Timmerman, Robert D.; Miften, Moyed

    2012-01-01

    .03). Additionally, ERB interventions reduced prostate deformation in the anterior–posterior (AP) direction, reduced errors in the sagittal rotation of the prostate, and increased the similarity in shape of the prostate to the radiotherapy plan (increased Dice coefficient from 0.76 ± 0.06 to 0.80 ± 0.04, p = 0.01). Postintervention decreases in prostate volume receiving less than the prescribed dose and decreases in the voxel-wise displacement of the prostate, bladder, and anterior rectal wall were observed, which resulted in improved dose–volume histogram (DVH) characteristics. Conclusions: Image-guided interventions in ERB volume and/or position during prostate SBRT were necessary to ensure the delivery of the dose distribution as planned. ERB interventions resulted in reductions in prostate deformations that would have prevented accurate localization of patient anatomy.

  14. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  15. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  16. Image guided prostate cancer treatments

    Energy Technology Data Exchange (ETDEWEB)

    Bard, Robert L. [Bard Cancer Center, Biofoundation for Angiogenesis Research and Development, New York, NY (United States); Fuetterer, Jurgen J. [Radboud Univ. Nijmegen, Medical Centre (Netherlands). Dept. of Radiology; Sperling, Dan (ed.) [Sperling Prostate Center, Alpha 3TMRI, New York, NY (United States)

    2014-07-01

    Systematic overview of the application of ultrasound and MRI in the diagnosis and treatment of diseases of the lower urinary tract. Detailed information on image-guided therapies, including focused ultrasound, photodynamic therapy, and microwave and laser ablation. Numerous high-quality illustrations based on high-end equipment. Represents the state of the art in Non Invasive Imaging and Minimally Invasive Ablation Treatment (MIAT). Image-Guided Prostate Cancer Treatments is a comprehensive reference and practical guide on the technology and application of ultrasound and MRI in the male pelvis, with special attention to the prostate. The book is organized into three main sections, the first of which is devoted to general aspects of imaging and image-guided treatments. The second section provides a systematic overview of the application of ultrasound and MRI to the diagnosis and treatment of diseases of the lower urinary tract. Performance of the ultrasound and MRI studies is explained, and the normal and abnormal pathological anatomy is reviewed. Correlation with the ultrasound in the same plane is provided to assist in understanding the MRI sequences. Biopsy and interventional procedures, ultrasound-MRI fusion techniques, and image-guided therapies, including focused ultrasound, photodynamic therapy, microwave and laser ablation, are all fully covered. The third section focuses on securing treatment effectiveness and the use of follow-up imaging to ensure therapeutic success and detect tumor recurrence at an early stage, which is vital given that prompt focal treatment of recurrence is very successful. Here, particular attention is paid to the role of Doppler ultrasound and DCE-MRI technologies. This book, containing a wealth of high-quality illustrations based on high-end equipment, will acquaint beginners with the basics of prostate ultrasound and MRI, while more advanced practitioners will learn new skills, means of avoiding pitfalls, and ways of effectively

  17. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  18. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2005-01-01

    An MR contrast agent targeted to the GRP receptor will be a novel pharmaceutical capable of non-invasively, and at high spatial resolution, characterizing healthy and patholological regions within the prostate...

  19. Towards Clinically Optimized MRI-guided Surgical Manipulator for Minimally Invasive Prostate Percutaneous Interventions: Constructive Design*

    Science.gov (United States)

    Eslami, Sohrab; Fischer, Gregory S.; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian

    2013-01-01

    This paper undertakes the modular design and development of a minimally invasive surgical manipulator for MRI-guided transperineal prostate interventions. Severe constraints for the MRI-compatibility to hold the minimum artifact on the image quality and dimensions restraint of the bore scanner shadow the design procedure. Regarding the constructive design, the manipulator kinematics has been optimized and the effective analytical needle workspace is developed and followed by proposing the workflow for the manual needle insertion. A study of the finite element analysis is established and utilized to improve the mechanism weaknesses under some inevitable external forces to ensure the minimum structure deformation. The procedure for attaching a sterile plastic drape on the robot manipulator is discussed. The introduced robotic manipulator herein is aimed for the clinically prostate biopsy and brachytherapy applications. PMID:24683502

  20. MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: Quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Scherr, M.K., E-mail: michael.scherr@med.uni-muenchen.de [Institute of Clinical Radiology, University of Munich, Munich (Germany); Seitz, M. [Department of Urology, University of Munich, Munich (Germany); Mueller-Lisse, U.G. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Ingrisch, M. [Josef Lissner Laboratory for Biomedical Imaging, Institute of Clinical Radiology, University of Munich, Munich (Germany); Reiser, M.F. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Mueller-Lisse, U.L. [Department of Urology, University of Munich, Munich (Germany)

    2010-12-15

    Background: Various MR methods, including MR-spectroscopy (MRS), dynamic, contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI) have been applied to improve test quality of standard MRI of the prostate. Purpose: To determine if quantitative, model-based MR-perfusion (MRP) with gadobenate dimeglumine (Gd-BOPTA) discriminates between prostate cancer, benign tissue, and transitional zone (TZ) tissue. Material and methods: 27 patients (age, 65 {+-} 4 years; PSA 11.0 {+-} 6.1 ng/ml) with clinical suspicion of prostate cancer underwent standard MRI, 3D MR-spectroscopy (MRS), and MRP with Gd-BOPTA. Based on results of combined MRI/MRS and subsequent guided prostate biopsy alone (17/27), biopsy and radical prostatectomy (9/27), or sufficient negative follow-up (7/27), maps of model-free, deconvolution-based mean transit time (dMTT) were generated for 29 benign regions (bROIs), 14 cancer regions (cROIs), and 18 regions of transitional zone (tzROIs). Applying a 2-compartment exchange model, quantitative perfusion analysis was performed including as parameters: plasma flow (PF), plasma volume (PV), plasma mean transit time (PMTT), extraction flow (EFL), extraction fraction (EFR), interstitial volume (IV) and interstitial mean transit time (IMTT). Two-sided T-tests (significance level p < 0.05) discriminated bROIs vs. cROIs and cROIs vs. tzROIs, respectively. Results: PMTT discriminated best between bROIs (11.8 {+-} 3.0 s) and cROIs (24.3 {+-} 9.6 s) (p < 0.0001), while PF, PV, PS, EFR, IV, IMTT also differed significantly (p 0.00002-0.0136). Discrimination between cROIs and tzROIs was insignificant for all parameters except PV (14.3 {+-} 2.5 ml vs. 17.6 {+-} 2.6 ml, p < 0.05). Conclusions: Besides MRI, MRS and DWI quantitative, 2-compartment MRP with Gd-BOPTA discriminates between prostate cancer and benign tissue with several parameters. However, distinction of prostate cancer and TZ does not appear to be reliable.

  1. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Anthony [Princess Alexandra Hospital, Brisbane (Australia); Miles, Kenneth [Princess Alexandra Hospital, Department of Diagnostic Radiology, Brisbane, QLD (Australia); University College London, Institute of Nuclear Medicine, London (United Kingdom)

    2017-12-15

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  2. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    International Nuclear Information System (INIS)

    Bates, Anthony; Miles, Kenneth

    2017-01-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  3. Feasibility of intermittent pneumatic compression for venous thromboembolism prophylaxis during magnetic resonance imaging-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Taslakian, Bedros, E-mail: bt05@aub.edu.lb [Department of Diagnostic Radiology, American University of Beirut Medical Center, Riad El-Solh, 1107 2020 Beirut (Lebanon); Durack, Jeremy C., E-mail: durackj@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Kaye, Elena A., E-mail: kayee@mskcc.org [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Srimathveeravalli, Govindarajan, E-mail: srimaths@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Solomon, Stephen B., E-mail: solomons@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States)

    2015-04-15

    Highlights: •The controller of a standard SCD is labeled as an “MR-unsafe”. •No commercially available “MR-safe” SCDs. •Standard SCDs can be used in iMRI by placing the device outside the MRI scanner room. •Using serial extension tubing did not cause device failure. -- Abstract: Purpose: Venous thromboembolism (VTE) is a common cause of morbidity and mortality in hospitalized and surgical patients. To reduce risk, perioperative VTE prophylaxis is recommended for cancer patients undergoing surgical or interventional procedures. Magnetic resonance imaging (MRI) is increasingly used in interventional oncology when alternative imaging modalities do not adequately delineate malignancies. Extended periods of immobilization during MRI-guided interventions necessitate an MR compatible sequential compression device (SCD) for intra-procedural mechanical VTE prophylaxis. Such devices are not commercially available. Materials and methods: A standard SCD routinely used at our institution for VTE prophylaxis during interventional procedures was used. To satisfy MR safety requirements, the SCD controller was placed in the MR control room and connected to the compression sleeves in the magnet room through the wave guide using tubing extensions. The controller pressure sensor was used to monitor adequate pressure delivery and detect ineffective low or abnormal high pressure delivery. VTE prophylaxis was provided using the above mentioned device for 38 patients undergoing MR-guided ablations. Results: There was no evidence of device failure due to loss of pressure in the extension tubing assembly. No interference with the anesthesia or interventional procedures was documented. Conclusion: Although the controller of a standard SCD is labeled as “MR-unsafe”, the SCD can be used in interventional MR settings by placing the device outside the MR scanner room. Using serial tubing extensions did not cause device failure. The described method can be used to provide

  4. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

  5. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    International Nuclear Information System (INIS)

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M. III; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed

  6. Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Anthony B [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Diederich, Chris J [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Nau, William H [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Gill, Harcharan [Department of Urology, Stanford University, Stanford, CA (United States); Bouley, Donna M [Department of Comparative Medicine, Stanford University, Stanford, CA (United States); Daniel, Bruce [Department of Radiology, Stanford University, Stanford, CA (United States); Rieke, Viola [Department of Radiology, Stanford University, Stanford, CA (United States); Butts, R Kim [Department of Radiology, Stanford University, Stanford, CA (United States); Sommer, Graham [Department of Radiology, Stanford University, Stanford, CA (United States)

    2004-01-21

    Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the tubular applicator ) produced coagulated zones covering a wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, {approx}8 MHz) generated thermal lesions of {approx}30 extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 each) demonstrated controllable coagulation of a 270 contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.

  7. Is MR imaging useful for detecting prostate cancer in cases requiring repeat biopsy?. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ito, Hirotoshi; Takahata, Akiko; Goto, Mariko; Masunami, Terutoshi; Yuen, Sachiko; Yamada, Kei; Nishimura, Tsunehiko

    2007-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance (MR) imaging in detecting prostate cancer in cases requiring repeat biopsy. Twenty patients with negative first prostate biopsy were evaluated by T2-weighted images (T 2 W), diffusion weighted image (DWI), and contrast-enhanced dynamic MRI at 1.5T prior to repeat biopsy. Eleven of the 20 also underwent MR imaging before initial biopsy. Cancer criteria were defined as an area of low signal intensity on T 2 W, high signal intensity on DWI, and early enhancement on dynamic MR imaging. We compared MR imaging findings with biopsy results. Prostate cancer was detected by repeat biopsy in nine of 20 patients. MR imaging demonstrated the cancer lesion in seven of the 9 patients whose biopsies were positive for cancer. MR imaging of 5 patients whose biopsies showed cancer also demonstrated cancer lesion previous to initial biopsy. Most cancers were detected in the anterior, apex, and far lateral areas. False-negative cases were low-grade cancers and had a few positive biopsy cores. In patients with repeat prostate biopsy, prior MR imaging may be valuable for detecting and localizing prostate cancer. (author)

  8. Prostate cancer: 1.5 T endo-coil dynamic contrast-enhanced MRI and MR spectroscopy-correlation with prostate biopsy and prostatectomy histopathological data

    DEFF Research Database (Denmark)

    Chabanova, E.; Balslev, I.; Løgager, Vibeke Berg

    2010-01-01

    PURPOSE: To investigate diagnostic accuracy of detection of prostate cancer by magnetic resonance: to evaluate the performance of T2WI, DCEMRI and CSI and to correlate the results with biopsy and radical prostatectomy histopathological data. MATERIALS AND METHODS: 43 patients, scheduled for radical...... techniques and histopathological findings on prostatectomy specimens. RESULTS: Prostate cancer was identified in all 43 patients by combination of the three MR techniques. The detection of prostate cancer on sextant-basis showed sensitivity and specificity: 50% and 91% for TRUS, 72% and 55% for T2WI, 49......% and 69% for DCEMRI, and 46% and 78% for CSI. CONCLUSION: T2WI, DCEMRI and CSI in combination can identify prostate cancer. Further development of MR technologies for these MR methods is necessary to improve the detection of the prostate cancer...

  9. Surface-based prostate registration with biomechanical regularization

    Science.gov (United States)

    van de Ven, Wendy J. M.; Hu, Yipeng; Barentsz, Jelle O.; Karssemeijer, Nico; Barratt, Dean; Huisman, Henkjan J.

    2013-03-01

    Adding MR-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound by using MRUS registration. A common approach is to use surface-based registration. We hypothesize that biomechanical modeling will better control deformation inside the prostate than a regular surface-based registration method. We developed a novel method by extending a surface-based registration with finite element (FE) simulation to better predict internal deformation of the prostate. For each of six patients, a tetrahedral mesh was constructed from the manual prostate segmentation. Next, the internal prostate deformation was simulated using the derived radial surface displacement as boundary condition. The deformation field within the gland was calculated using the predicted FE node displacements and thin-plate spline interpolation. We tested our method on MR guided MR biopsy imaging data, as landmarks can easily be identified on MR images. For evaluation of the registration accuracy we used 45 anatomical landmarks located in all regions of the prostate. Our results show that the median target registration error of a surface-based registration with biomechanical regularization is 1.88 mm, which is significantly different from 2.61 mm without biomechanical regularization. We can conclude that biomechanical FE modeling has the potential to improve the accuracy of multimodal prostate registration when comparing it to regular surface-based registration.

  10. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application.

    Science.gov (United States)

    Barkhausen, Jörg; Kahn, Thomas; Krombach, Gabriele A; Kuhl, Christiane K; Lotz, Joachim; Maintz, David; Ricke, Jens; Schönberg, Stefan O; Vogl, Thomas J; Wacker, Frank K

    2017-07-01

    Background  MRI is attractive for the guiding and monitoring of interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure physiologic parameters like flow and cardiac function. Method  The current status of interventional MRI for the clinical routine was analyzed. Results  The effort needed for the development of MR-safe monitoring systems and instruments initially resulted in the application of interventional MRI only for procedures that could not be performed by other means. Accordingly, biopsy of lesions in the breast, which are not detectable by other modalities, has been performed under MRI guidance for decades. Currently, biopsies of the prostate under MRI guidance are established in a similar fashion. At many sites blind biopsy has already been replaced by MR-guided biopsy or at least by the fusion of MR images with ultrasound. Cardiovascular interventions are performed at several centers for ablation as a treatment for atrial fibrillation. Conclusion  Interventional MRI has been established in the clinical routine for a variety of indications. Broader application can be expected in the clinical routine in the future owing to the multiple advantages compared to other techniques. Key points   · Due to the significant technical effort, MR-guided interventions are only recommended in the long term for regions in which MRI either facilitates or greatly improves the intervention.. · Breast biopsy of otherwise undetectable target lesions has long been established in the clinical routine. Prostate biopsy is currently being introduced in the clinical routine for similar reasons. Other methods such as MR-guided focused ultrasound for the treatment of uterine fibroids or tumor ablation of metastases represent alternative methods and are offered in many places.. · Endovascular MR-guided interventions offer advantages for a number of indications and have already been clinically established for the treatment of

  11. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V. (Dept. of Medical Physics, Oncology, Aalborg Hospital (Denmark))

    2008-08-15

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  12. A new fiducial marker for Image-guided radiotherapy of prostate cancer: clinical experience.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Højkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V

    2008-01-01

    A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs.

  13. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V.

    2008-01-01

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  14. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    OpenAIRE

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian...

  15. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2008-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot perform...

  16. MR imaging of noncancerous lesions of the prostate gland

    International Nuclear Information System (INIS)

    Lovett, K.; Rifkin, M.D.; Choi, H.Y.; McCue, P.; Mitchell, D.G.; Burk, D.L. Jr.

    1990-01-01

    This paper determines the importance of MR signal characteristics in noncancerous lesions of the prostate. Step-sectioned radical prostatectomy specimens from over 50 individuals with stage A or B cancer were retrospectively reviewed and compared with correlative axial T2-weighted MR images obtained just prior to surgery. Noncancerous lesions were evaluated for signal intensity and location. Focal high-signal-intensity areas were present in 82% of patients. The 28% of lesions in the central gland correlated with cystic atrophy. Of the lesions in the peripheral prostate, 85% were cystic atrophy without associated cancer, 7.5% cystic atrophy with cancer, and 7.5% focal inflammation. Focal low-signal-intensity areas were present in 76% of patients. Of the 31% in the central prostate, one-fifth correlated with benign prostatic hyperplasia (BPH) and four-fifths with fibrous tissue, 10% to the 69% that were peripheral, 82% corresponded to fibrous tissue, 10% to BPH, and 8% to normal tissue. Mixed lesions were present in 73%; 93% of these were located centrally and 7% peripherally. All mixed central lesions were BPH, and the peripheral 7% were areas of combined cystic atrophy and fibrosis

  17. A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Li, Saying; Chen, Min; Wang, Wenchao; Zhao, Weifeng; Zhou, Cheng (Dept. of Radiology, Beijing Hospital, Beijing (China)), e-mail: chenmin62@yahoo.com; Wang, Jianye (Dept. of Urology, Beijing Hospital, Beijing (China)); Zhao, Xuna (Philips Medical System (China))

    2011-04-15

    Background: MR elastography is a new imaging tool capable of non-invasively assessing the viscoelastic properties of tissues. The clinical application of MR elastography in the diagnosis of prostate cancer remains to be elucidated. Purpose: To investigate the feasibility of MR elastography in the diagnosis of prostate cancer at 3.0T, and to assess the elasticity and viscosity of prostate cancer and benign prostatic disease. Material and Methods: Eight patients (63 +- 7.25 years old) with 12 foci of prostate cancer and 10 patients (59 +- 3.25 years old) with 14 foci of prostatitis in the peripheral zone were evaluated by MRE. Ten healthy volunteers (41 +- 4.32 years old) with 18 ROIs in the peripheral zone of the prostate were also assessed with MR elastography as a control group. The results were confirmed by histopathological findings. All examinations were performed on a 3.0T Philips Achieva scanner. MRE was implemented by transmitting low-frequency longitudinal mechanical waves of 100Hz into the prostate with a transducer placed above the pubic bones. The phase images were reconstructed to acquire viscoelastic mapping. T-test was used to compare the mean elasticity and viscosity of prostate cancer and prostatitis. A comparison of prostate cancer and healthy prostate tissue in elasticity was also evaluated. The correlation of elasticity and Gleason scores between prostate cancer and prostatitis were retrospectively analyzed with Pearson Correlation. Results: The mean elasticity and viscosity were significantly higher in the lesions with prostate cancer (6.55 +- 0.47 kPa, 6.56 +- 0.99 Pa.s, respectively) than in regions with prostatitis (1.99 +- 0.66 kPa, 2.13 +- 0.21 Pa.s). The difference between prostate cancer and prostatitis was statistically significant (t = 19.392, p < 0.01; t = 16.372, p < 0.01). The elasticity and viscosity of the healthy peripheral zone of prostate were 2.26 +- 0.45 kPa, 2.38 +- 0.54 Pa.s, respectively. There also was significant

  18. Efficient 3D multi-region prostate MRI segmentation using dual optimization.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    Efficient and accurate extraction of the prostate, in particular its clinically meaningful sub-regions from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, we propose a novel multi-region segmentation approach to simultaneously locating the boundaries of the prostate and its two major sub-regions: the central gland and the peripheral zone. The proposed method utilizes the prior knowledge of the spatial region consistency and employs a customized prostate appearance model to simultaneously segment multiple clinically meaningful regions. We solve the resulted challenging combinatorial optimization problem by means of convex relaxation, for which we introduce a novel spatially continuous flow-maximization model and demonstrate its duality to the investigated convex relaxed optimization problem with the region consistency constraint. Moreover, the proposed continuous max-flow model naturally leads to a new and efficient continuous max-flow based algorithm, which enjoys great advantages in numerics and can be readily implemented on GPUs. Experiments using 15 T2-weighted 3D prostate MR images, by inter- and intra-operator variability, demonstrate the promising performance of the proposed approach.

  19. Analysis of the spatial and temporal accuracy of heating in the prostate gland using transurethral ultrasound therapy and active MR temperature feedback

    International Nuclear Information System (INIS)

    Chopra, Rajiv; Tang, Kee; Burtnyk, Mathieu; Boyes, Aaron; Bronskill, Michael; Sugar, Linda; Appu, Sree; Klotz, Laurence

    2009-01-01

    A new MRI-guided therapy is being developed as a minimally invasive treatment for localized prostate cancer utilizing high-intensity ultrasound energy to generate a precise region of thermal coagulation within the prostate gland. The purpose of this study was to evaluate in vivo the capability to produce a spatial heating pattern in the prostate that accurately matched the shape of a target region using transurethral ultrasound heating and active MR temperature feedback. Experiments were performed in a canine model (n = 9) in a 1.5 T MR imager using a prototype device comprising a single planar transducer operated under rotational control. The spatial temperature distribution, measured every 5 s with MR thermometry, was used to adjust the acoustic power and rotation rate in order to achieve a temperature of 55 0 C along the outer boundary of the target region. The results demonstrated the capability to produce accurate spatial heating patterns within the prostate gland. An average temperature of 56.2 ± 0.6 0 C was measured along the outer boundary of the target region across all experiments in this study. The average spatial error between the target boundary and the 55 0 C isotherm was 0.8 ± 0.7 mm (-0.2 to 3.2 mm), and the overall treatment time was ≤20 min for all experiments. Excellent spatial agreement was observed between the temperature information acquired with MRI and the pattern of thermal damage measured on H and E-stained tissue sections. This study demonstrates the benefit of adaptive energy delivery using active MR temperature feedback, and an excellent capability to treat precise regions within the prostate gland with this technology.

  20. Automatic prostate MR image segmentation with sparse label propagation and domain-specific manifold regularization.

    Science.gov (United States)

    Liao, Shu; Gao, Yaozong; Shi, Yinghuan; Yousuf, Ambereen; Karademir, Ibrahim; Oto, Aytekin; Shen, Dinggang

    2013-01-01

    Automatic prostate segmentation in MR images plays an important role in prostate cancer diagnosis. However, there are two main challenges: (1) Large inter-subject prostate shape variations; (2) Inhomogeneous prostate appearance. To address these challenges, we propose a new hierarchical prostate MR segmentation method, with the main contributions lying in the following aspects: First, the most salient features are learnt from atlases based on a subclass discriminant analysis (SDA) method, which aims to find a discriminant feature subspace by simultaneously maximizing the inter-class distance and minimizing the intra-class variations. The projected features, instead of only voxel-wise intensity, will be served as anatomical signature of each voxel. Second, based on the projected features, a new multi-atlases sparse label fusion framework is proposed to estimate the prostate likelihood of each voxel in the target image from the coarse level. Third, a domain-specific semi-supervised manifold regularization method is proposed to incorporate the most reliable patient-specific information identified by the prostate likelihood map to refine the segmentation result from the fine level. Our method is evaluated on a T2 weighted prostate MR image dataset consisting of 66 patients and compared with two state-of-the-art segmentation methods. Experimental results show that our method consistently achieves the highest segmentation accuracies than other methods under comparison.

  1. SU-E-T-245: MR Guided Focused Ultrasound Increased PARP Related Apoptosis On Prostate Cancer in Vivo

    International Nuclear Information System (INIS)

    Chen, L; Chen, X; Cvetkovic, D; Gupta, R; Yang, D; Ma, C

    2014-01-01

    Purpose: Our previous study demonstrated that significant tumor growth delay was observed in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. Temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level, which is the intensity of the DAB reaction. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality might be able to synergize with PARP inhibitors to achieve better result

  2. A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0T

    International Nuclear Information System (INIS)

    Li, Saying; Chen, Min; Wang, Wenchao; Zhao, Weifeng; Zhou, Cheng; Wang, Jianye; Zhao, Xuna

    2011-01-01

    Background: MR elastography is a new imaging tool capable of non-invasively assessing the viscoelastic properties of tissues. The clinical application of MR elastography in the diagnosis of prostate cancer remains to be elucidated. Purpose: To investigate the feasibility of MR elastography in the diagnosis of prostate cancer at 3.0T, and to assess the elasticity and viscosity of prostate cancer and benign prostatic disease. Material and Methods: Eight patients (63 ± 7.25 years old) with 12 foci of prostate cancer and 10 patients (59 ± 3.25 years old) with 14 foci of prostatitis in the peripheral zone were evaluated by MRE. Ten healthy volunteers (41 ± 4.32 years old) with 18 ROIs in the peripheral zone of the prostate were also assessed with MR elastography as a control group. The results were confirmed by histopathological findings. All examinations were performed on a 3.0T Philips Achieva scanner. MRE was implemented by transmitting low-frequency longitudinal mechanical waves of 100Hz into the prostate with a transducer placed above the pubic bones. The phase images were reconstructed to acquire viscoelastic mapping. T-test was used to compare the mean elasticity and viscosity of prostate cancer and prostatitis. A comparison of prostate cancer and healthy prostate tissue in elasticity was also evaluated. The correlation of elasticity and Gleason scores between prostate cancer and prostatitis were retrospectively analyzed with Pearson Correlation. Results: The mean elasticity and viscosity were significantly higher in the lesions with prostate cancer (6.55 ± 0.47 kPa, 6.56 ± 0.99 Pa.s, respectively) than in regions with prostatitis (1.99 ± 0.66 kPa, 2.13 ± 0.21 Pa.s). The difference between prostate cancer and prostatitis was statistically significant (t = 19.392, p < 0.01; t = 16.372, p < 0.01). The elasticity and viscosity of the healthy peripheral zone of prostate were 2.26 ± 0.45 kPa, 2.38 ± 0.54 Pa.s, respectively. There also was significant

  3. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong

    1994-01-01

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system

  4. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-06-15

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system.

  5. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  6. SU-F-J-225: Histology Study of MR Guided Pulsed Focused Ultrasound On Treatment of Prostate Cancer in Vivo

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L; Cvetkovic, D; Chen, X; Wang, B; Gupta, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Our previous study demonstrated significant tumor growth delay in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. The temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level using the DAB analysis software. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality may synergize with PARP inhibitors to achieve better therapeutic result.

  7. SU-F-J-225: Histology Study of MR Guided Pulsed Focused Ultrasound On Treatment of Prostate Cancer in Vivo

    International Nuclear Information System (INIS)

    Chen, L; Cvetkovic, D; Chen, X; Wang, B; Gupta, R; Ma, C

    2016-01-01

    Purpose: Our previous study demonstrated significant tumor growth delay in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. The temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level using the DAB analysis software. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality may synergize with PARP inhibitors to achieve better therapeutic result.

  8. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  9. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  10. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Paetzel, C.; Zorger, N.; Bachthaler, M.; Voelk, M.; Seitz, J.; Herold, T.; Feuerbach, S.; Lenhart, M.; Nitz, W.R.

    2004-01-01

    Purpose: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. Materials and Methods: Three patients (1 female, 2 male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n=2) or popliteal (n=1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71-88%. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035'' guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. Results: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed

  11. Differentiation of prostate cancer from benign prostate hypertrophy using dual-echo dynamic contrast MR imaging

    International Nuclear Information System (INIS)

    Muramoto, Satoshi; Uematsu, Hidemasa; Kimura, Hirohiko; Ishimori, Yoshiyuki; Sadato, Norihiro; Oyama, Nobuyuki; Matsuda, Tsuyoshi; Kawamura, Yasutaka; Yonekura, Yoshiharu; Okada, Kenichiro; Itoh, Harumi

    2002-01-01

    Objective: To investigate the usefulness of dynamic contrast magnetic resonance (MR) imaging in the differentiation of prostate cancer (PC) from benign prostate hypertrophy (BPH). Materials and methods: Eleven PC patients and 13 BPH patients were entered into the analysis. The mean gradient (MG) was calculated from the T2* term-eliminated time-signal intensity curve obtained from dynamic contrast MR data, and the MG of PC and that of BPH were compared. Results: The MG of PC was significantly higher than that of BPH. When the threshold value was set to 1.88% per s for discriminating PC from BPH, the sensitivity, specificity, and accuracy were 100, 85, and 92%, respectively. Conclusion: The MG, which is derived from the T2* term-eliminated time-signal intensity curve, may be a useful index for differentiating PC from BPH

  12. Predictive power of the ESUR scoring system for prostate cancer diagnosis verified with targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmöller, L.; Quentin, M.; Arsov, C.; Hiester, A.; Kröpil, P.; Rabenalt, R.; Albers, P.; Antoch, G.; Blondin, D.

    2014-01-01

    Highlights: • The PI-RADS summed score (PS sum ) demonstrated very good diagnostic values, especially for higher grade PCa. • Lesions with PS sum ≥13 represented prostate cancer in 88% and higher grade prostate cancer in 42%. • Sensitivity and NPV was nearly 100% for higher grade PCa detection using a cut-off limit of PS sum 10. • Peripheral zone lesions demonstrated better diagnostic value with the PS sum compared to transitional zone lesions. • Further improvement of the PI-RADS score is required to prevent unnecessary overdiagnosis. - Abstract: Purpose: This study evaluates the diagnostic value of the ESUR scoring system (PI-RADS) regarding prostate cancer detection using MR-guided in-bore biopsies (IB-GB) as the reference standard. Methods: 566 lesions in 235 consecutive patients (65.7 ± 7.9 years, PSA 9.9 ± 8.5 ng/ml) with a multiparametric (mp)-MRI (T2WI, DWI, DCE) of the prostate at 3 T were scored using the PI-RADS scoring system. PI-RADS single (PS single ), summed (PS sum ), and overall (PS overall ) scores were determined. All lesions were histologically verified by IB-GB. Results: Lesions with a PS sum below 9 contained no prostate cancer (PCa) with Gleason score (GS) ≥ 4 + 3 = 7. A PS sum of 13–15 (PS overall V) resulted in 87.8% (n = 108) in PCa and in 42.3% (n = 52) in GS ≥ 4 + 3 = 7. Transition zone (TZ) lesions with a PS sum of 13–15 (PS overall V) resulted in 76.3% (n = 36) in PCa and in 26.3% (n = 10) in GS ≥ 4 + 3 = 7, whereas for peripheral zone (PZ) lesions cancer detection rate at this score was 92.9% (n = 79) and 49.4% (n = 42) for GS ≥ 4 + 3 = 7. Using a threshold of PS sum ≥ 10, sensitivity was 86.0%, and negative predictive value (NPV) was 86.2%. For higher grade PCa sensitivity was 98.6%, and NPV was 99.5%. Conclusion: A PS sum below 9 excluded a higher grade PCa, whereas lesions with a PS sum ≥ 13 (PS overall V) represented in 88% PCa, and in 42% higher grade PCa. The PS sum or PS overall demonstrated a

  13. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  14. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Zijlstra, Frank; Sikkes, Gonda G.; de Boer, Hans C. J.; Meijer, Gert J.; Kerkmeijer, Linda G. W.; Viergever, Max A.; Lagendijk, Jan J. W.; Seevinck, Peter R.

    2017-10-01

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of 1.1 × 1.1 × 1.2 mm3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a

  15. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy.

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A T; Zijlstra, Frank; Sikkes, Gonda G; de Boer, Hans C J; Meijer, Gert J; Kerkmeijer, Linda G W; Viergever, Max A; Lagendijk, Jan J W; Seevinck, Peter R

    2017-10-03

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of [Formula: see text] mm 3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a

  16. Clinical utility of an endorectal MRI-guided prostate probe: preliminary examinations

    Directory of Open Access Journals (Sweden)

    Tödter Julia

    2017-09-01

    Full Text Available Prostate cancer (PCa is one of the most common cancer diseases in men in the western countries [1]. Besides the palpation, and the amount of prostate-specific-antigen’s (PSA inside the blood, the current diagnostic imaging technologies are not appropriate. Early diagnosis defining the exact tumor location, spread and margins could make efficient targeted biopsies and image-guided surgery. A multimodal imaging technique containing a transmit-receive surface coil for anatomical MR imaging, a (SPET detector module, consisting of silicon photomultipliers (SiPM, for functional imaging and an ultrasound (US probe are placed as close as possible to the prostate designed as an endorectal tube to increase sensitivity and spatial resolution. All materials that are used are non-magnetic. Advantages of the SiPM are diversified, like non-sensitive to magnetic fields, higher gain (105–106 than standard avalanche photodiodes (APD, good timing properties and compactness. The PET detector should reach approximately 1mm3 spatial resolution together with 60ps FWHM Time-of-Flight resolution and a high efficiency to reduce scanning time and injected dose. A home-made transmit-receive coil surrounding the PET module improves signal-to-noise-ratio (SNR with respect to standard coils will be present. The system will be used as a MRI-insert and be able to visualize anatomic and metabolic information together. The US-probe is guiding examination for correct overlapping of the multimodal images. This procedure will save time, costs and the need of co-registration. By combining all advantages of each system, it will necessarily update the non-invasive treatment of PCa. The system is adapted and tested to a 3 Tesla MR scanner called Trio A Tim system and Allegra system from the company Siemens healthcare with a larmor frequency of 123.2 MHz and an input of 50 Ω free from artifacts. First results on homogeneity of the transmit-receive coil will be presented. Preliminary

  17. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    Energy Technology Data Exchange (ETDEWEB)

    Khalvati, Farzad, E-mail: farzad.khalvati@uwaterloo.ca; Tizhoosh, Hamid R. [Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Salmanpour, Aryan; Rahnamayan, Shahryar [Department of Engineering and Applied Science, University of Ontario Institute of Technology, Oshawa, Ontario L1H 7K4 (Canada); Rodrigues, George [Department of Radiation Oncology, London Regional Cancer Program, London, Ontario N6C 2R6, Canada and Department of Epidemiology/Biostatistics, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2013-12-15

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

  18. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    International Nuclear Information System (INIS)

    Khalvati, Farzad; Tizhoosh, Hamid R.; Salmanpour, Aryan; Rahnamayan, Shahryar; Rodrigues, George

    2013-01-01

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability

  19. Why and Where do We Miss Significant Prostate Cancer with Multi-parametric Magnetic Resonance Imaging followed by Magnetic Resonance-guided and Transrectal Ultrasound-guided Biopsy in Biopsy-naïve Men?

    Science.gov (United States)

    Schouten, Martijn G; van der Leest, Marloes; Pokorny, Morgan; Hoogenboom, Martijn; Barentsz, Jelle O; Thompson, Les C; Fütterer, Jurgen J

    2017-06-01

    Knowledge of significant prostate (sPCa) locations being missed with magnetic resonance (MR)- and transrectal ultrasound (TRUS)-guided biopsy (Bx) may help to improve these techniques. To identify the location of sPCa lesions being missed with MR- and TRUS-Bx. In a referral center, 223 consecutive Bx-naive men with elevated prostate specific antigen level and/or abnormal digital rectal examination were included. Histopathologically-proven cancer locations, Gleason score, and tumor length were determined. All patients underwent multi-parametric MRI and 12-core systematic TRUS-Bx. MR-Bx was performed in all patients with suspicion of PCa on multi-parametric MRI (n=142). Cancer locations were compared between MR- and TRUS-Bx. Proportions were expressed as percentages, and the corresponding 95% confidence intervals were calculated. In total, 191 lesions were found in 108 patients with sPCa. From these lesion 74% (141/191) were defined as sPCa on either MR- or TRUS-Bx. MR-Bx detected 74% (105/141) of these lesions and 61% (86/141) with TRUS-Bx. TRUS-Bx detected more lesions compared with MR-Bx (140 vs 109). However, these lesions were often low risk (39%). Significant lesions missed with MR-Bx most often had involvement of dorsolateral (58%) and apical (37%) segments and missed segments with TRUS-Bx were located anteriorly (79%), anterior midprostate (50%), and anterior apex (23%). Both techniques have difficulties in detecting apical lesions. MR-Bx most often missed cancer with involvement of the dorsolateral part (58%) and TRUS-Bx with involvement of the anterior part (79%). Both biopsy techniques miss cancer in specific locations within the prostate. Identification of these lesions may help to improve these techniques. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. MR spectroscopy of normal prostate, prostate cancer and benign prostate hyperplasia: correlative study of metabolic characteristics with histopathological findings

    International Nuclear Information System (INIS)

    Zhou Liangping; Wang Xiaoying; Ding Jianping; Li Feiyu; Shan Gangzhi; Xiao Jiangxi; Jiang Xuexiang

    2005-01-01

    Objective: To quantify and compare the metabolic characteristics of normal prostate, prostate cancer (PCa), and benign prostate hyperplasia (BPH) by using MR spectroscopy (MRS). Methods: Twenty-one cases of Pca, 23 cases of BPH proved by operation or systemic biopsy, and 17 cases of normal prostate were examined by MRS. The prostate was divided into 6 regions (left/ right bottom, middle, and tip), and the (Choline + Creatine)/Citrate (CC/C) value of each region was measured. After biopsy, all the puncture locations were marked and enrolled in one of the regions mentioned above. The average CC/C ratios of the normal prostate peripheral zone, the area of Pca, and the central zone of BPH were calculated. Results: The average ratio of CC/C for prostate cancer (2.13 ± 0.82) was statistically higher than that of normal prostate tissue (0.42 ± 0.19) and the regions of BPH (0.62 ± 0.19) (t 0.725, P=0.000; t=0.684, P=0.000). Conclusion: The difference of metabolic levels measured by MRS between PCa and BPH is statistically significant. MRS may be useful in the differential diagnosis of PCa and BPH. (authors)

  1. Treatment of osteoid osteoma using CT-guided radiofrequency ablation versus MR-guided laser ablation: A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Gebauer, B.; Wieners, G.; De Bucourt, M.; Renz, D.M.; Hamm, B.; Streitparth, F.

    2012-01-01

    Objective: To compare the costs of CT-guided radiofrequency ablation (RFA) and MR-guided laser ablation (LA) for minimally invasive percutaneous treatment of osteoid osteoma. Materials and methods: Between November 2005 and October 2011, 20 patients (14 males, 6 females, mean age 20.3 ± 9.1 years) underwent CT-guided RFA and 24 patients (18 males, 6 females; mean age, 23.8 ± 13.8 years) MR-guided LA (open 1.0 Tesla, Panorama HFO, Philips, Best, Netherlands) for osteoid osteoma diagnosed on the basis of clinical presentation and imaging findings. Prorated costs of equipment use (purchase, depreciation, and maintenance), staff costs, and expenditure for disposables were identified for CT-guided RFA and MR-guided LA procedures. Results: The average total costs per patient were EUR 1762 for CT-guided RFA and EUR 1417 for MR-guided LA. These were (RFA/LA) EUR 92/260 for equipment use, EUR 149/208 for staff, and EUR 870/300 for disposables. Conclusion: MR-guided LA is less expensive than CT-guided RFA for minimally invasive percutaneous ablation of osteoid osteoma. The higher costs of RFA are primarily due to the higher price of the disposable RFA probes.

  2. Atlas-based deformable image registration for MRI-guided prostate radiation therapy

    International Nuclear Information System (INIS)

    Dowling, J.; Fripp, J.; Salvado, O.; Lambert, J.; Denham, J.W.; Capp, A.; Grer, P.B.; Parker, J.

    2010-01-01

    Full text: To develop atlas-based deformable image registration methods to automatically segment organs and map electron densities to pelvic MRI scans for MRI-guided radiation therapy. Methods An MRT pelvic atlas and corresponding CT atlas were developed based on whole pelvic T 2 MRI scans and CT scans for 39 patients. Expert manual segmentations on both MRI and CT scans were obtained. The atlas was deformably registered to the individual patient MRI scans for automatic prostate, rectum, bladder and bone segmentation. These were compared to the manual segmentations using the Dice overlap coefficient. The same deformation vectors were then applied to the CT-atlas to produce pseudo-CT scans that correspond to the patient MRI scan anatomy but are populated with Hounsfield units. The original patient plan was recalculated on the pseudo-CT and compared to the original CT plan and bulk density plans on the MRI scans. Results Dice coefficient results were high (>0.8) for bone and prostate but lower (<0.7) for bladder and rectum which exhibit greater changes in shape and volume. Doses calculated on pseudo-CT scans were within 3% of original patient plans. Two sources of discrepancy were found; MR anatomy differences from CT due to patient setup differences at the MR scanner. and Hounsfield unit differences for bone in the pseudo-CT from original CT. Patient setup will be adressed with a

  3. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    International Nuclear Information System (INIS)

    Vilanova, J.C.; Barcelo, J.; Comet, J.; Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E.; Barcelo, C.

    2001-01-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year -1 ). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging. (orig.)

  4. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Vilanova, J.C.; Barcelo, J. [Ressonancia Girona, Clinica Girona, Girona (Spain); Comet, J. [Dept. of Urology, Univ. Hospital of Girona (Spain); Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E. [Centre Diagnostic Pedralbes, Cetir Grup Medic, Barcelona (Spain); Barcelo, C. [Dept. of Computer Science and Applied Mathematics, University of Girona (Spain)

    2001-02-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year{sup -1}). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging

  5. Predictive power of the ESUR scoring system for prostate cancer diagnosis verified with targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmöller, L., E-mail: Lars.Schimmoeller@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Quentin, M., E-mail: Michael.Quentin@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Arsov, C., E-mail: Cristian.Arsov@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Hiester, A., E-mail: Andreas.Hiester@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Kröpil, P., E-mail: Patric.Kroepil@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Rabenalt, R., E-mail: Robert.Rabenalt@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Albers, P., E-mail: urologie@uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Antoch, G., E-mail: Antoch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Blondin, D., E-mail: Dirk.Blondin@sk-mg.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany)

    2014-12-15

    Highlights: • The PI-RADS summed score (PS{sub sum}) demonstrated very good diagnostic values, especially for higher grade PCa. • Lesions with PS{sub sum} ≥13 represented prostate cancer in 88% and higher grade prostate cancer in 42%. • Sensitivity and NPV was nearly 100% for higher grade PCa detection using a cut-off limit of PS{sub sum} 10. • Peripheral zone lesions demonstrated better diagnostic value with the PS{sub sum} compared to transitional zone lesions. • Further improvement of the PI-RADS score is required to prevent unnecessary overdiagnosis. - Abstract: Purpose: This study evaluates the diagnostic value of the ESUR scoring system (PI-RADS) regarding prostate cancer detection using MR-guided in-bore biopsies (IB-GB) as the reference standard. Methods: 566 lesions in 235 consecutive patients (65.7 ± 7.9 years, PSA 9.9 ± 8.5 ng/ml) with a multiparametric (mp)-MRI (T2WI, DWI, DCE) of the prostate at 3 T were scored using the PI-RADS scoring system. PI-RADS single (PS{sub single}), summed (PS{sub sum}), and overall (PS{sub overall}) scores were determined. All lesions were histologically verified by IB-GB. Results: Lesions with a PS{sub sum} below 9 contained no prostate cancer (PCa) with Gleason score (GS) ≥ 4 + 3 = 7. A PS{sub sum} of 13–15 (PS{sub overall} V) resulted in 87.8% (n = 108) in PCa and in 42.3% (n = 52) in GS ≥ 4 + 3 = 7. Transition zone (TZ) lesions with a PS{sub sum} of 13–15 (PS{sub overall} V) resulted in 76.3% (n = 36) in PCa and in 26.3% (n = 10) in GS ≥ 4 + 3 = 7, whereas for peripheral zone (PZ) lesions cancer detection rate at this score was 92.9% (n = 79) and 49.4% (n = 42) for GS ≥ 4 + 3 = 7. Using a threshold of PS{sub sum} ≥ 10, sensitivity was 86.0%, and negative predictive value (NPV) was 86.2%. For higher grade PCa sensitivity was 98.6%, and NPV was 99.5%. Conclusion: A PS{sub sum} below 9 excluded a higher grade PCa, whereas lesions with a PS{sub sum} ≥ 13 (PS{sub overall} V) represented in 88

  6. Experimental MR-guided cryotherapy of the brain with almost real-time imaging by radial k-space scanning

    International Nuclear Information System (INIS)

    Tacke, J.; Schorn, R.; Glowinski, A.; Grosskortenhaus, S.; Adam, G.; Guenther, R.W.; Rasche, V.

    1999-01-01

    Purpose: To test radial k-space scanning by MR fluoroscopy to guide and control MR-guided interstitial cryotherapy of the healthy pig brain. Methods: After MR tomographic planning of the approach, an MR-compatible experimental cryotherapy probe of 2.7 mm diameter was introduced through a 5 mm burr hole into the right frontal brain of five healthy pigs. The freeze-thaw cycles were imaged using a T 1 -weighted gradient echo sequence with radial k-space scanning in coronal, sagittal, and axial directions. Results: The high temporal resolution of the chosen sequence permits a continuous representation of the freezing process with good image quality and high contrast between ice and unfrozen brain parenchyma. Because of the interactive conception of the sequence the layer plane could be chosen as desired during the measurement. Ice formation was sharply demarcated, spherically configurated, and was free of signals. Its maximum diameter was 13 mm. Conclusions: With use of the novel, interactively controllable gradient echo sequence with radial k-space scanning, guidance of the intervention under fluoroscopic conditions with the advantages of MRT is possible. MR-guided cryotherapy allows a minimally-invasive, precisely dosable focal tissue ablation. (orig.) [de

  7. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  8. A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

    International Nuclear Information System (INIS)

    Zachiu, Cornel; Moonen, Chrit; Ries, Mario; Denis de Senneville, Baudouin

    2015-01-01

    Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that

  9. A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

    Energy Technology Data Exchange (ETDEWEB)

    Zachiu, Cornel, E-mail: C.Zachiu@umcutrecht.nl; Moonen, Chrit; Ries, Mario [Imaging Division, UMC Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, UMC Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Mathematical Institute of Bordeaux, University of Bordeaux, Talence Cedex 33405 (France)

    2015-07-15

    Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that

  10. Visualizing the prostate gland by MR imaging in young and old mice.

    Directory of Open Access Journals (Sweden)

    Murali Ravoori

    Full Text Available Prostate imaging requires optimization in young and old mouse models. We tested which MR sequences and field strengths best depict the prostate gland in young and old mice; and, whether prostate MR signal, size, and architecture change with age.Magnetic resonance imaging (MRI of the prostate of young (2 months and old (18 months male nude mice (n = 6 was performed at 4.7 and 7 T and SCID mice (n = 6 at 7 T field strengths, using T1, fat suppressed T1, DWI, T2, fat suppressed T2, as well as T2-based- and proton density-based Dixon "water only" sequences. Images were ranked for best overall sequence for prostate visualization, prostate delineation, and quality of fat suppression. Prostate volume and signal characteristics were compared and histology was performed.T2-based-Dixon "water only" images ranked best overall for prostate visualization and delineation as well as fat suppression (n = 6, P<0.001 at both 4.7 T and 7 T in nude and 7T in SCID mice. Evaluated in nude mice, T2-based Dixon "water only" had greater prostate CNR and lower fat SNR at 7 T than 4.7 T (P<0.001. Prostate volume was less in older than younger mice (n = 6, P<0.02 nude mice; n = 6, P<0.002 SCID mice. Prostate T2 FSE as well as proton density-based and T2-based-Dixon "water only" signal intensity was higher in younger than older mice (P<0.001 nude mice; P<0.01 SCID mice both at 4.7 and 7 T. This corresponded to an increase in glandular hyperplasia in older mice by histology (P<0.01, n = 6.T2-based Dixon "water only" images best depict the mouse prostate in young and old nude mice at 4.7 and 7 T. The mouse prostate decreases in size with age. The decrease in T2 and T2-based Dixon "water only" signal with age corresponds with glandular hyperplasia. Findings suggest age should be an important determinant when choosing models of prostate biology and disease.

  11. Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases

    NARCIS (Netherlands)

    Lam, Mie K; Huisman, Merel; Nijenhuis, Robbert J; van den Bosch, Maurice; Viergever, Max A; Moonen, Chrit Tw; Bartels, LW

    2015-01-01

    BACKGROUND: Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of

  12. A framework for the correction of slow physiological drifts during MR-guided HIFU therapies : Proof of concept

    NARCIS (Netherlands)

    Zachiu, Cornel; de Senneville, Baudouin Denis; Moonen, Chrit; Ries, Mario

    Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During

  13. Long term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, P; Rasmussen, F; Holm, H H [Depts. of Urology and Ultrasound, Herlev Hospital, Univ. of Copenhagen (Denmark)

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months. Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is bigger than 0.5 ng/ml in 8 of these. The future role of ultrasonically guided implantation in the management of prostatic cancer is discussed. (au).

  14. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer.

    Science.gov (United States)

    Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip

    2017-12-31

    Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  15. Effectiveness of Educational Intervention on the Congruence of Prostate and Rectal Contouring as Compared With a Gold Standard in Three-Dimensional Radiotherapy for Prostate

    International Nuclear Information System (INIS)

    Szumacher, Ewa; Harnett, Nicole; Warner, Saar; Kelly, Valerie; Danjoux, Cyril; Barker, Ruth; Woo, Milton; Mah, Kathy; Ackerman, Ida; Dubrowski, Adam; Rose, Stuart; Crook, Juanita

    2010-01-01

    Purpose: To examine effects of a teaching intervention on precise delineation of the prostate and rectum during planning of three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: A pretest, posttest, randomized controlled group design was used. During pretest all participants contoured prostate and rectum on planning CT. Afterward, they participated in two types of workshops. The experimental group engaged in an interactive teaching session focused on prostate and rectum MR anatomy compared with CT anatomy. The control group focused on 3D-CRT planning without mention of prostate or rectal contouring. The experimental group practiced on fused MR-CT images, whereas the control group practiced on CT images. All participants completed the posttest. Results: Thirty-one trainees (12 male, 19 female) were randomly assigned to two groups, 17 in the experimental arm, and 14 in the control group. Seventeen felt familiar or very familiar with pelvic organ contouring, 12 somewhat, and 2 had never done it. Thirteen felt confident with organ contouring, 13 somewhat, and 5 not confident. The demographics and composition of groups were analyzed with χ 2 and repeated-measures analysis of variance with the two groups (experimental or control) and two tests (pre- or posttest) as factors. Satisfaction with the course and long-term effects of the course on practice were assessed with immediate and delayed surveys. All performance variables showed a similar pattern of results. Conclusions: The training sessions improved the technical performance similarly in both groups. Participants were satisfied with the course content, and the delayed survey reflected that cognitively participants felt more confident with prostate and rectum contouring and would investigate opportunities to learn more about organ contouring.

  16. Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: In vivo evaluation under MR guidance

    International Nuclear Information System (INIS)

    Kinsey, Adam M.; Diederich, Chris J.; Rieke, Viola; Nau, William H.; Pauly, Kim Butts; Bouley, Donna; Sommer, Graham

    2008-01-01

    initially centered on each sector that coalesced within ∼5 min to produce uniform and contiguous zones of thermal destruction between sectors, with smooth outer boundaries and continued radial propagation in time. The dimension of the coagulation zone along the applicator was well-defined by positioning and active array length. Although not as precise as rotating planar and curvilinear devices currently under development for MR-guided procedures, advantages of these multi-sectored transurethral applicators include a flexible delivery catheter and that mechanical manipulation of the device using rotational motors is not required during therapy. This multi-sectored tubular array transurethral ultrasound technology has demonstrated potential for relatively fast and reasonably conformal targeting of prostate volumes suitable for the minimally invasive treatment of BPH and cancer under MR guidance, with further development warranted

  17. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  18. SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Vaitheeswaran, R; Sivaramakrishnan, KR; Kumar, Prashant; Gattamaneni, Raja; Kumar, Girish [Philips India Limited, Bangalore, Karnataka (India)

    2016-06-15

    Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

  19. Subacute posteromedial impingement of the ankle in athletes: MR imaging evaluation and ultrasound guided therapy

    International Nuclear Information System (INIS)

    Messiou, Christina; Robinson, Philip; O'Connor, Philip J.; Grainger, Andrew

    2006-01-01

    To describe the use of MR imaging and efficacy of ultrasound-guided steroid injection in the diagnosis and management of athletes with clinical posteromedial impingement of the ankle. A retrospective analysis of imaging findings on MR was undertaken in nine elite athletes with clinical posteromedial ankle impingement. MR studies from six professional athletes with posterolateral pain were also reviewed as an imaging control group. The two reviewing radiologists were blinded to the clinical details and the proportion of control and study subjects. The nine study athletes also underwent diagnostic ultrasound and ultrasound-guided injection of steroid and anaesthetic into the posteromedial capsular abnormality. Follow-up was by telephone interview. Posteromedial capsular thickening was seen only in athletes with posteromedial impingement (7/9). Posteromedial synovitis was present in all athletes with posteromedial impingement; however, posterior and posterolateral synovitis was also seen in these athletes. Mild posteromedial synovitis was present in two control athletes. Ultrasound identified abnormal posteromedial soft tissue thickening deep to tibialis posterior between the medial malleolus and talus in all nine athletes. After injection all athletes returned to their previous level of sport, with eight of the nine not experiencing any residual or recurrent symptoms. If MR imaging excludes significant coexistent abnormality, ultrasound can localise posteromedial soft tissue abnormality and guide injection therapy, allowing return to athletic activity without surgical intervention. (orig.)

  20. In-Bore Prostate Transperineal Interventions with an MRI-guided Parallel Manipulator: System Development and Preliminary Evaluation

    Science.gov (United States)

    Eslami, Sohrab; Shang, Weijian; Li, Gang; Patel, Nirav; Fischer, Gregory S.; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian

    2015-01-01

    Background The robot-assisted minimally-invasive surgery is well recognized as a feasible solution for diagnosis and treatment of the prostate cancer in human. Methods In this paper the kinematics of a parallel 4 Degrees-of-Freedom (DOF) surgical manipulator designed for minimally invasive in-bore prostate percutaneous interventions through the patient's perineum. The proposed manipulator takes advantage of 4 sliders actuated by MRI-compatible piezoelectric motors and incremental rotary encoders. Errors, mostly originating from the design and manufacturing process, need to be identified and reduced before the robot is deployed in the clinical trials. Results The manipulator has undergone several experiments to evaluate the repeatability and accuracy of the needle placement which is an essential concern in percutaneous prostate interventions. Conclusion The acquired results endorse the sustainability, precision (about 1 mm in air (in x or y direction) at the needle's reference point) and reliability of the manipulator. PMID:26111458

  1. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  2. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin Fangfang; Gao Qinghuai; Xie Huchen; Nelson, Diana F.; Yu Yan; Kwok, W. Edmund; Totterman, Saara; Schell, Michael C.; Rubin, Philip

    1998-01-01

    Purpose: To investigate a method for the generation of digitally reconstructed radiographs directly from MR images (DRR-MRI) to guide a computerized portal verification procedure. Methods and Materials: Several major steps were developed to perform an MR image-guided portal verification procedure. Initially, a wavelet-based multiresolution adaptive thresholding method was used to segment the skin slice-by-slice in MR brain axial images. Some selected anatomical structures, such as target volume and critical organs, were then manually identified and were reassigned to relatively higher intensities. Interslice information was interpolated with a directional method to achieve comparable display resolution in three dimensions. Next, a ray-tracing method was used to generate a DRR-MRI image at the planned treatment position, and the ray tracing was simply performed on summation of voxels along the ray. The skin and its relative positions were also projected to the DRR-MRI and were used to guide the search of similar features in the portal image. A Canny edge detector was used to enhance the brain contour in both portal and simulation images. The skin in the brain portal image was then extracted using a knowledge-based searching technique. Finally, a Chamfer matching technique was used to correlate features between DRR-MRI and portal image. Results: The MR image-guided portal verification method was evaluated using a brain phantom case and a clinical patient case. Both DRR-CT and DRR-MRI were generated using CT and MR phantom images with the same beam orientation and then compared. The matching result indicated that the maximum deviation of internal structures was less than 1 mm. The segmented results for brain MR slice images indicated that a wavelet-based image segmentation technique provided a reasonable estimation for the brain skin. For the clinical patient case with a given portal field, the MR image-guided verification method provided an excellent match between

  3. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer

    Directory of Open Access Journals (Sweden)

    Bedriye Koyuncu Sokmen

    2017-12-01

    Full Text Available Purpose: Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. Methods: A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1 (n = 20 (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7. Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. Results: ADC values of the cases in Group 3 were lower than those of the other groups (p 0.05. Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001. Conclusion: In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  4. Metabolite ratios in 1H MR spectroscopic imaging of the prostate

    NARCIS (Netherlands)

    Kobus, T.; Wright, A.J.; Weiland, E.; Heerschap, A.; Scheenen, T.W.J.

    2015-01-01

    In (1)H MR spectroscopic imaging ((1)H-MRSI) of the prostate the spatial distribution of the signal levels of the metabolites choline, creatine, polyamines, and citrate are assessed. The ratio of choline (plus spermine as the main polyamine) plus creatine over citrate [(Cho+(Spm+)Cr)/Cit] is derived

  5. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  6. Role of endorectal MR imaging and MR spectroscopic imaging in defining treatable intraprostatic tumor foci in prostate cancer: Quantitative analysis of imaging contour compared to whole-mount histopathology

    International Nuclear Information System (INIS)

    Anwar, Mekhail; Westphalen, Antonio C.; Jung, Adam J.; Noworolski, Susan M.; Simko, Jeffry P.; Kurhanewicz, John; Roach, Mack; Carroll, Peter R.; Coakley, Fergus V.

    2014-01-01

    Purpose: To investigate the role of endorectal MR imaging and MR spectroscopic imaging in defining the contour of treatable intraprostatic tumor foci in prostate cancer, since targeted therapy requires accurate target volume definition. Materials and methods: We retrospectively identified 20 patients with prostate cancer who underwent endorectal MR imaging and MR spectroscopic imaging prior to radical prostatectomy and subsequent creation of detailed histopathological tumor maps from whole-mount step sections. Two experienced radiologists independently reviewed all MR images and electronically contoured all suspected treatable (⩾0.5 cm 3 ) tumor foci. Deformable co-registration in MATLAB was used to calculate the margin of error between imaging and histopathological contours at both capsular and non-capsular surfaces and the treatment margin required to ensure at least 95% tumor coverage. Results: Histopathology showed 17 treatable tumor foci in 16 patients, of which 8 were correctly identified by both readers and an additional 2 were correctly identified by reader 2. For all correctly identified lesions, both readers accurately identified that tumor contacted the prostatic capsule, with no error in contour identification. On the non-capsular border, the median distance between the imaging and histopathological contour was 1.4 mm (range, 0–12). Expanding the contour by 5 mm at the non-capsular margin included 95% of tumor volume not initially covered within the MR contour. Conclusions: Endorectal MR imaging and MR spectroscopic imaging can be used to accurately contour treatable intraprostatic tumor foci; adequate tumor coverage is achieved by expanding the treatment contour at the non-capsular margin by 5 mm

  7. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  8. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    International Nuclear Information System (INIS)

    Halliwell, O.T.; Yadegafar, G.; Lane, C.; Dewbury, K.C.

    2008-01-01

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications

  9. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    Energy Technology Data Exchange (ETDEWEB)

    Halliwell, O.T. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)], E-mail: hallo99@doctors.org.uk; Yadegafar, G. [Public Health Sciences and Medical Statistics Division, School of Medicine, Southampton General Hospital, Southampton University, Southampton (United Kingdom); Lane, C.; Dewbury, K.C. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)

    2008-05-15

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications.

  10. Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

    International Nuclear Information System (INIS)

    Hsu, Charles C.; Hsu, Howard; Pickett, Barby; Crehange, Gilles; Hsu, I-Chow Joe; Dea, Ryan; Weinberg, Vivian; Gottschalk, Alexander R.; Kurhanewicz, John; Shinohara, Katsuto; Roach, Mack

    2013-01-01

    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or ≥7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound-guided

  11. Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Charles C., E-mail: hsucc@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Hsu, Howard [Department of Radiation Oncology, New York University, New York, New York (United States); Pickett, Barby [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Crehange, Gilles [Department of Radiation Oncology, Dijon University, Dijon (France); Hsu, I-Chow Joe; Dea, Ryan [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Weinberg, Vivian [Biostatistics and Computational Biology Core, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Gottschalk, Alexander R. [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Kurhanewicz, John [Department of Radiology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Shinohara, Katsuto [Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States)

    2013-02-01

    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound-guided

  12. Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy.

    Science.gov (United States)

    Rivest-Hénault, David; Dowson, Nicholas; Greer, Peter B; Fripp, Jurgen; Dowling, Jason A

    2015-07-01

    CT-MR registration is a critical component of many radiation oncology protocols. In prostate external beam radiation therapy, it allows the propagation of MR-derived contours to reference CT images at the planning stage, and it enables dose mapping during dosimetry studies. The use of carefully registered CT-MR atlases allows the estimation of patient specific electron density maps from MRI scans, enabling MRI-alone radiation therapy planning and treatment adaptation. In all cases, the precision and accuracy achieved by registration influences the quality of the entire process. Most current registration algorithms do not robustly generalize and lack inverse-consistency, increasing the risk of human error and acting as a source of bias in studies where information is propagated in a particular direction, e.g. CT to MR or vice versa. In MRI-based treatment planning where both CT and MR scans serve as spatial references, inverse-consistency is critical, if under-acknowledged. A robust, inverse-consistent, rigid/affine registration algorithm that is well suited to CT-MR alignment in prostate radiation therapy is presented. The presented method is based on a robust block-matching optimization process that utilises a half-way space definition to maintain inverse-consistency. Inverse-consistency substantially reduces the influence of the order of input images, simplifying analysis, and increasing robustness. An open source implementation is available online at http://aehrc.github.io/Mirorr/. Experimental results on a challenging 35 CT-MR pelvis dataset demonstrate that the proposed method is more accurate than other popular registration packages and is at least as accurate as the state of the art, while being more robust and having an order of magnitude higher inverse-consistency than competing approaches. The presented results demonstrate that the proposed registration algorithm is readily applicable to prostate radiation therapy planning. Copyright © 2015. Published by

  13. A Randomized Controlled Trial for the Effectiveness of Progressive Muscle Relaxation and Guided Imagery as Anxiety Reducing Interventions in Breast and Prostate Cancer Patients Undergoing Chemotherapy

    Directory of Open Access Journals (Sweden)

    Andreas Charalambous

    2015-01-01

    Full Text Available Objective. To test the effectiveness of guided imagery (GI and progressive muscle relaxation (PMR as stress reducing interventions in patients with prostate and breast cancer who undergo chemotherapy. Methods. Patients were randomly assigned to either the control group or the intervention group (PMR and GI. Patients were observed for a total duration of 3 weeks and assessed with the SAS and BECK-II questionnaires for anxiety and depression, respectively, in addiotion to two biological markers (saliva cortisol and saliva amylase (trial registration number: NCT01275872. Results. 256 patients were registered and 236 were randomly assigned. In total 104 were randomised to the control group and 104 to the intervention group. Intervention’s mean anxiety score and depression score changes were significantly different compared to the control’s (b=-29.4, p<0.001; b=-29.4, p<0.001, resp.. Intervention group’s cortisol levels before the intervention (0.30±0.25 gradually decreased up to week 3 (0.16±0.18, whilst the control group’s cortisol levels before the intervention (0.21±0.22 gradually increased up to week 3 (0.44±0.35. The same interaction appears for the Amylase levels (p<0.001. Conclusions. The findings showed that patients with prostate and breast cancer undergoing chemotherapy treatment can benefit from PMR and GI sessions to reduce their anxiety and depression.

  14. Interventional MR imaging: state of the art and future perspectives

    International Nuclear Information System (INIS)

    Kahn, T.; Moedder, U.

    1998-01-01

    The concept of MR guidance of invasive diagnostic and minimally invasive therapeutic procedures is based on the excellent morphologic and functional properties of MR imaging. Prerequisites are adequate patient monitoring and adherence to safety guidelines. Fast and ultrafast sequences, temperature quantification, visualization of intravascular devices, thermal stability of contrast media and thermosensitive contrast media are discussed. The spectrum of clinical applications includes biopsies, thermal ablation modalities, vascular applications, MR endoscopy and intraoperative MR imaging. The development of interventional MR imaging is still in its infancy. In the future, MR imaging may play an important role in interventional radiology and minimally invasive therapy. (orig.) [de

  15. Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System.

    Science.gov (United States)

    Lillaney, Prasheel V; Yang, Jeffrey K; Losey, Aaron D; Martin, Alastair J; Cooke, Daniel L; Thorne, Bradford R H; Barry, David C; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W

    2016-10-01

    Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic

  16. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, Martijn G. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); University Medical Centre Nijmegen, Department of Radiology, Nijmegen (Netherlands); Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Rothgang, Eva [Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Center for Applied Medical Imaging, Siemens Corporate Research (Germany); Center for Applied Medical Imaging, Siemens Corporate Research, Baltimore, MD (United States); Misra, Sarthak [University of Twente, MIRA-Institute of Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2012-02-15

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  17. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    International Nuclear Information System (INIS)

    Schouten, Martijn G.; Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J.; Rothgang, Eva; Misra, Sarthak

    2012-01-01

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  18. Development of a Combined MR Fingerprinting and Diffusion Examination for Prostate Cancer.

    Science.gov (United States)

    Yu, Alice C; Badve, Chaitra; Ponsky, Lee E; Pahwa, Shivani; Dastmalchian, Sara; Rogers, Matthew; Jiang, Yun; Margevicius, Seunghee; Schluchter, Mark; Tabayoyong, William; Abouassaly, Robert; McGivney, Debra; Griswold, Mark A; Gulani, Vikas

    2017-06-01

    Purpose To develop and evaluate an examination consisting of magnetic resonance (MR) fingerprinting-based T1, T2, and standard apparent diffusion coefficient (ADC) mapping for multiparametric characterization of prostate disease. Materials and Methods This institutional review board-approved, HIPAA-compliant retrospective study of prospectively collected data included 140 patients suspected of having prostate cancer. T1 and T2 mapping was performed with fast imaging with steady-state precession-based MR fingerprinting with ADC mapping. Regions of interest were drawn by two independent readers in peripheral zone lesions and normal-appearing peripheral zone (NPZ) tissue identified on clinical images. T1, T2, and ADC were recorded for each region. Histopathologic correlation was based on systematic transrectal biopsy or cognitively targeted biopsy results, if available. Generalized estimating equations logistic regression was used to assess T1, T2, and ADC in the differentiation of (a) cancer versus NPZ, (b) cancer versus prostatitis, (c) prostatitis versus NPZ, and (d) high- or intermediate-grade tumors versus low-grade tumors. Analysis was performed for all lesions and repeated in a targeted biopsy subset. Discriminating ability was evaluated by using the area under the receiver operating characteristic curve (AUC). Results In this study, 109 lesions were analyzed, including 39 with cognitively targeted sampling. T1, T2, and ADC from cancer (mean, 1628 msec ± 344, 73 msec ± 27, and 0.773 × 10 -3 mm 2 /sec ± 0.331, respectively) were significantly lower than those from NPZ (mean, 2247 msec ± 450, 169 msec ± 61, and 1.711 × 10 -3 mm 2 /sec ± 0.269) (P fingerprinting- and diffusion-based examination for quantitative characterization of prostatic tissue. © RSNA, 2017 Online supplemental material is available for this article.

  19. Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Dietrich, J.; Lieberenz, S.; Schmidt, F.; Sorge, O.; Trantakis, C.; Seifert, V.; Kellermann, S.; Schober, R.; Franke, P.

    1999-01-01

    The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR ''SIGNA SP'' (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device ''Flashpoint Position Encoder'' (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence. (orig.)

  20. Diagnostic Accuracy of Selective 3-T MR Neurography-guided Retroperitoneal Genitofemoral Nerve Blocks for the Diagnosis of Genitofemoral Neuralgia.

    Science.gov (United States)

    Fritz, Jan; Dellon, A Lee; Williams, Eric H; Rosson, Gedge D; Belzberg, Allan J; Eckhauser, Frederick E

    2017-10-01

    Purpose To determine if 3-T magnetic resonance (MR) neurography-guided retroperitoneal genitofemoral nerve (GFN) blocks are safe and effective for the diagnosis of genitofemoral neuralgia. Materials and Methods Following institutional review board approval and informed consent, 26 subjects (16 men, 10 women; mean age, 42 years [range, 24-78 years]; mean body mass index, 28 kg/m 2 [range, 20-35 kg/m 2 ]) with intractable groin pain were included. By using a 3-T MR imaging system, intermediate-weighted turbo spin-echo pulse sequences, and MR-conditional needles, diagnostic MR neurography-guided GFN blocks were performed in the retroperitoneum. Outcome variables included technical success, procedure time, complications, and rates of positive and negative GFN blocks in association with therapeutic outcomes. For the assessment of a learning curve, Mann-Whitney test was used. P values ≤ .05 were considered to indicate a statistically significant difference. Results In 26 subjects, 30 retroperitoneal GFN blocks were performed. Twelve (40%) were performed with an anterior needle path, 12 (40%) with a lateral needle path, and six (20%) with a posterior needle path. GFN blocks were technically successful in 24 of 26 (92%) subjects, achieving appropriate scrotal anesthesia. No complications occurred. The time required for a GFN block was 40 minutes (range, 18-67 minutes). The rate of a successful GFN intervention after a positive GFN block was 88% (14 of 16). The rate of a successful intervention of an alternative target after a negative GFN block was 71% (five of seven). Conclusion Selective retroperitoneally directed MR neurography-guided GFN blocks are safe and effective with high technical success and positive effect on surgical decision making in patients with presumed genitofemoral neuralgia. © RSNA, 2017 Online supplemental material is available for this article.

  1. Describing a nurse case manager intervention to empower low-income men with prostate cancer.

    Science.gov (United States)

    Maliski, Sally L; Clerkin, Barbara; Litwin, Mark S

    2004-01-01

    Describe and categorize nurse case manager (NCM) interventions for low-income, uninsured men with prostate cancer. Descriptive, retrospective record review. Statewide free prostate cancer treatment program in which each patient is assigned an NCM. 7 NCMs who developed interventions based on empowerment through increasing self-efficacy. NCM entries were extracted and coded from 10 electronic patient records, line by line, to reveal initial themes. Themes were grouped under categories. Investigators then reviewed and expanded these categories and their descriptions and postulated linkages. Linkages and relationships among categories were empirically verified with the original data. NCM entries from another 20 records were prepared in the same manner as the original records. Modifications were made until the categories contained all of the data and no new categories emerged. Categories were verified for content validity with the NCMs and reviewed for completeness and representation. NCM interventions. Categories of NCM interventions emerged as assessment, coordination, advocacy, facilitation, teaching, support, collaborative problem solving, and keeping track. Categories overlapped and supported each other. NCMs tailored interventions by combining categories for each patient. The skillful tailoring and execution of intervention strategies depended on the knowledge, experience, and skill that each NCM brought to the clinical situation. NCM categories were consistent with the tenets of the self-efficacy theory. The model, based on NCM interventions, provides a guide for the care of underserved men with prostate cancer. Components of the model need to be tested.

  2. Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy

    Science.gov (United States)

    Wyatt, Jonathan J.; Dowling, Jason A.; Kelly, Charles G.; McKenna, Jill; Johnstone, Emily; Speight, Richard; Henry, Ann; Greer, Peter B.; McCallum, Hazel M.

    2017-12-01

    There is increasing interest in MR-only radiotherapy planning since it provides superb soft-tissue contrast without the registration uncertainties inherent in a CT-MR registration. However, MR images cannot readily provide the electron density information necessary for radiotherapy dose calculation. An algorithm which generates synthetic CTs for dose calculations from MR images of the prostate using an atlas of 3 T MR images has been previously reported by two of the authors. This paper aimed to evaluate this algorithm using MR data acquired at a different field strength and a different centre to the algorithm atlas. Twenty-one prostate patients received planning 1.5 T MR and CT scans with routine immobilisation devices on a flat-top couch set-up using external lasers. The MR receive coils were supported by a coil bridge. Synthetic CTs were generated from the planning MR images with (sCT1V ) and without (sCT) a one voxel body contour expansion included in the algorithm. This was to test whether this expansion was required for 1.5 T images. Both synthetic CTs were rigidly registered to the planning CT (pCT). A 6 MV volumetric modulated arc therapy plan was created on the pCT and recalculated on the sCT and sCT1V . The synthetic CTs’ dose distributions were compared to the dose distribution calculated on the pCT. The percentage dose difference at isocentre without the body contour expansion (sCT-pCT) was Δ D_sCT=(0.9 +/- 0.8) % and with (sCT1V -pCT) was Δ D_sCT1V=(-0.7 +/- 0.7) % (mean  ±  one standard deviation). The sCT1V result was within one standard deviation of zero and agreed with the result reported previously using 3 T MR data. The sCT dose difference only agreed within two standard deviations. The mean  ±  one standard deviation gamma pass rate was Γ_sCT = 96.1 +/- 2.9 % for the sCT and Γ_sCT1V = 98.8 +/- 0.5 % for the sCT1V (with 2% global dose difference and 2~mm distance to agreement gamma criteria). The one voxel body contour

  3. Use of a newly developed piezoelectrically driven drilling machine for MR-guided bone biopsies

    International Nuclear Information System (INIS)

    Fritzsch, D.; Werner, A.; Kahn, T.

    2002-01-01

    Purpose: Development and clinical testing of an MR-compatible bone biopsy system, to enable the sample collection from osteosclerotic or subcortical lesions for histological investigation under MR control. Materials and Methods: A piezoelectrically driven drilling machine was constructed and tested in connection with an MR-compatible bone biopsy set in a vertical open MR scanner (0.5 T) on a phantom and 10 patients with ambiguous bone lesions. Images were obtained using T 1 -weighted spin-echo sequences and, in case of real-time imaging, a fast spoiled gradient-echo sequence. Results: The influence of the enabled motor (RF-interference) leads to a reduction of the signal to noise ratio of the images, but can be minimised by appropriate measures. The observed slight field distorsions do not affect the image quality during real time acquisition in a substantial manner. No complications occurred. The extracted biopsy material was sufficient and of good quality. Conclusions: In spite of slightly restricted image quality, the described drilling machine combined with the bone biopsy set is well suited for MR-guided bone biopsies, which require the application of a motor driven drill. Its application within an interventional MR scanner is safe and its handling simple and manageable. (orig.) [de

  4. Comparison of MR imaging and urodynamic findings in benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Alam, A.M.; Ishida, Jun; Igawa, Mikio; Sugimura, Kazuro; Okizuka, Hiromi

    2000-01-01

    In benign prostatic hyperplasia (BPH), it is uncertain whether the size of the prostate is related to the degree of urodynamically demonstrated bladder outlet obstruction. We compared MR imaging findings and urodynamic data in patients with surgically confirmed BPH. We prospectively studied 43 benign prostatic hyperplasia (BPH) patients in whom transurethral resection of the prostate (TURP) was planned. We obtained T1- and T2-weighted images in the transverse and sagittal planes with a 1.5 Tesla superconducting unit. The predicted volume of the inner gland and the peripheral zone were obtained on T2-weighted transverse images. Prostatic protrusion into the urinary bladder (IB protrusion) and the inner gland ratio (IG ratio: inner gland volume/total prostatic volume) were determined. IB protrusion and inner IG ratio were significantly greater in patients with severe stenosis than in those without. A surgical capsule (SC) was seen in 20 of 25 patients (80%) with severe stenosis and 8 of 18 (44%) of those without it. The accuracy of IB protrusion + IG ratio, IB protrusion + surgical capsule, and IB protrusion + IG ratio + surgical capsule was 89%, and that of IG ratio + surgical capsule was 86%. The inner gland ratio, protrusion into the bladder, and presence of surgical capsule were the most important factors in bladder outlet obstruction. The probability of outlet stenosis increases in patients with more than two of these criteria. (author)

  5. Comparison of MR imaging and urodynamic findings in benign prostatic hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Alam, A.M.; Ishida, Jun; Igawa, Mikio [Shimane Medical Univ., Izumo (Japan); Sugimura, Kazuro; Okizuka, Hiromi

    2000-04-01

    In benign prostatic hyperplasia (BPH), it is uncertain whether the size of the prostate is related to the degree of urodynamically demonstrated bladder outlet obstruction. We compared MR imaging findings and urodynamic data in patients with surgically confirmed BPH. We prospectively studied 43 benign prostatic hyperplasia (BPH) patients in whom transurethral resection of the prostate (TURP) was planned. We obtained T1- and T2-weighted images in the transverse and sagittal planes with a 1.5 Tesla superconducting unit. The predicted volume of the inner gland and the peripheral zone were obtained on T2-weighted transverse images. Prostatic protrusion into the urinary bladder (IB protrusion) and the inner gland ratio (IG ratio: inner gland volume/total prostatic volume) were determined. IB protrusion and inner IG ratio were significantly greater in patients with severe stenosis than in those without. A surgical capsule (SC) was seen in 20 of 25 patients (80%) with severe stenosis and 8 of 18 (44%) of those without it. The accuracy of IB protrusion + IG ratio, IB protrusion + surgical capsule, and IB protrusion + IG ratio + surgical capsule was 89%, and that of IG ratio + surgical capsule was 86%. The inner gland ratio, protrusion into the bladder, and presence of surgical capsule were the most important factors in bladder outlet obstruction. The probability of outlet stenosis increases in patients with more than two of these criteria. (author)

  6. A software tool for advanced MRgFUS prostate therapy planning and follow up

    Science.gov (United States)

    van Straaten, Dörte; Hoogenboom, Martijn; van Amerongen, Martinus J.; Weiler, Florian; Issawi, Jumana Al; Günther, Matthias; Fütterer, Jurgen; Jenne, Jürgen W.

    2017-03-01

    US guided HIFU/FUS ablation for the therapy of prostate cancer is a clinical established method, while MR guided HIFU/FUS applications for prostate recently started clinical evaluation. Even if MRI examination is an excellent diagnostic tool for prostate cancer, it is a time consuming procedure and not practicable within an MRgFUS therapy session. The aim of our ongoing work is to develop software to support therapy planning and post-therapy follow-up for MRgFUS on localized prostate cancer, based on multi-parametric MR protocols. The clinical workflow of diagnosis, therapy and follow-up of MR guided FUS on prostate cancer was deeply analyzed. Based on this, the image processing workflow was designed and all necessary components, e.g. GUI, viewer, registration tools etc. were defined and implemented. The software bases on MeVisLab with several implemented C++ modules for the image processing tasks. The developed software, called LTC (Local Therapy Control) will register and visualize automatically all images (T1w, T2w, DWI etc.) and ADC or perfusion maps gained from the diagnostic MRI session. This maximum of diagnostic information helps to segment all necessary ROIs, e.g. the tumor, for therapy planning. Final therapy planning will be performed based on these segmentation data in the following MRgFUS therapy session. In addition, the developed software should help to evaluate the therapy success, by synchronization and display of pre-therapeutic, therapy and follow-up image data including the therapy plan and thermal dose information. In this ongoing project, the first stand-alone prototype was completed and will be clinically evaluated.

  7. Non-invasive pre-clinical MR imaging of prostate tumor hypoxia for radiation therapy prognosis

    Directory of Open Access Journals (Sweden)

    Derek White

    2014-03-01

    Full Text Available Purpose: To investigate the usefulness of Oxygen-Enhanced Magnetic Resonance Imaging (OE-MRI changes in signal intensity related to oxygen challenge for predicting tumor response to radiation therapy.Methods: Dynamic MR signal changes were acquired using Varian 4.7T small animal MR scanner prior to image-guided radiation therapy (IGRT of small (n = 6 and large subcutaneous (n = 5 prostate tumors in adult male rats. An interleaved blood-oxygen level dependent (BOLD and tissue-oxygen level dependent (TOLD data acquisition or (IBT was performed using a baseline of medical air as positive control and using medical oxygen as a breathing challenge. BOLD used a 2-D multi-slice spoiled gradient-echo with multi-echo sequence. TOLD used a 2-D multi-slice spoiled gradient-echo sequence. Voxel changes in signal intensity were determined by a correlation coefficient mapping technique. Irradiation technique planned consisted of 1F × 15 Gy AP/PA or 2F × 7.5 Gy AP/PA to the gross tumor volume (GTV. Tumor growth measurements were recorded over time to assess the response to IGRT.Results: BOLD and TOLD signals variously illustrated positive or negative impulse responses in the tumor ROI due to inhaling medical oxygen. Correlation coefficient mapping demonstrated heterogeneity in tumors after inhaling medical oxygen. BOLD and TOLD signals exhibited increased changes in signal intensities after the first fraction of dose. Multi-fractionation had minimum effect until the second fraction of dose was applied. Tumor growth delays were observed when inhaling medical oxygen during IGRT.Conclusion: OE-MRI is a non-invasive imaging modality that can provide insight to the oxygen status of tumors. Observed increase percent changes in BOLD and TOLD signal intensities after the first fraction of dose suggest tumors experienced reoxygenation. OE-MRI could be used for predicting tumor response to IGRT when using medical oxygen for increasing GTV radiosensitivity, suggesting

  8. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  9. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  10. MR-guided joint reconstruction of activity and attenuation in brain PET-MR

    DEFF Research Database (Denmark)

    Mehranian, Abolfazl; Zaidi, Habib; Reader, Andrew J

    2017-01-01

    by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this algorithm can be effectively addressed by imposing MR spatial constraints on the estimation of attenuation maps using a penalized MLAA (P-MLAA(+)) algorithm. With the advent of simultaneous PET-MR systems......, MRI-guided PET image reconstruction has also gained attention for improving the quantitative accuracy of PET images, usually degraded by noise and partial volume effects. The aim of this study is therefore to increase the benefits of MRI information for improving the quantitative accuracy of PET...... as a reference. The simulation results showed that the proposed method can notably improve the visual quality of the PET images by reducing noise while preserving structural boundaries and at the same time improving the quantitative accuracy of the PET images. Our clinical reconstruction results showed...

  11. White paper. Interventional MRI. Current status and potential for development considering economic perspectives. Pt. 1. General application; White Paper. Interventionelle MRT. Status Quo und Entwicklungspotenzial unter oekonomischen Perspektiven. T. 1. Generelle Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, Joerg [Univ. Hospital Schleswig Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine; Kahn, Thomas [Clinic and Policlinic for Diagnostic and Interventional Radiology, Leipzig (Germany); Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Kuhl, Christiane K. [Univ. Hospital RWTH Aachen (Germany). Dept. of Diagnostic and Interventional Radiology; Lotz, Joachim [Univ. Goettingen (Germany). Inst. for Diagnostic and Interventional Radiology; Maintz, David [Univ. Hospital Cologne (Germany). Dept. of Radiology; Ricke, Jens [Univ. Hospital Magdeburg (Germany). Dept. of Radiology and Nuclear Medicine; Schoenberg, Stefan O. [Heidelberg Univ. - Univ. Medical Center Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Vogl, Thomas J. [Univ. Hospital Frankfurt (Germany). Dept. of Diagnostic and Interventional Radiology; Wacker, Frank K. [Hannover Medical School (Germany). Dept. for Diagnostic and Interventional Radiology

    2017-07-15

    MRI is attractive for the guiding and monitoring of interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure physiologic parameters like flow and cardiac function. The current status of interventional MRI for the clinical routine was analyzed. The effort needed for the development of MR-safe monitoring systems and instruments initially resulted in the application of interventional MRI only for procedures that could not be performed by other means. Accordingly, biopsy of lesions in the breast, which are not detectable by other modalities, has been performed under MRI guidance for decades. Currently, biopsies of the prostate under MRI guidance are established in a similar fashion. At many sites blind biopsy has already been replaced by MR-guided biopsy or at least by the fusion of MR images with ultrasound. Cardiovascular interventions are performed at several centers for ablation as a treatment for atrial fibrillation. Interventional MRI has been established in the clinical routine for a variety of indications. Broader application can be expected in the clinical routine in the future owing to the multiple advantages compared to other techniques.

  12. Interventional and intravascular MR angiography

    International Nuclear Information System (INIS)

    Ladd, M.E.; Debatin, J.F.

    2000-01-01

    Magnetic resonance imaging (MRI) has a number of characteristics which make it attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in any arbitrary oblique plane, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity and volume per unit time. For MR guidance of vascular interventions to be safe, catheters and guidewires must be visualized relative to the vascular system and surrounding tissues. A number of approaches for making instruments visible in an MR environment are presented, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts, whereas active techniques, including MR tracking, MR profiling, and active field inhomogeneity, use some form of electrical coil built into the instrument. The potential for obtaining high-resolution images of the vessel wall using coils built into a catheter is also discussed. These images provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications beyond those currently performed under X-ray fluoroscopic guidance. (orig.) [de

  13. Inter-reader agreement of multi-parametric MR imaging for the detection of prostate cancer. Evaluation of a scoring system

    International Nuclear Information System (INIS)

    Quentin, M.; Roehlen, S.; Klasen, J.; Antoch, G.; Blondin, D.; Arsov, C.; Albers, P.

    2012-01-01

    Purpose: Functional prostate MR is performed in varying combinations of T2-weighted images with diffusion-weighted imaging (DWI), dynamic contrast-enhanced MRI (DCE-MRI), and spectroscopic imaging (MRSI). Recently, a European consensus meeting proposed the use of a simple 5-point scale for estimating the probability of a lesion being malignant. The aim of the present study was to determine the inter-reader agreement of MR imaging using a scoring system based on the recommendations of the consensus. Materials and Methods: The appearance of 108 predefined lesions in three different MR sequences (T2-weighted images, DWI, and DCE-MRI) in 50 functional prostate MR examinations were retrospectively scored by three blinded radiologists using a 5-point scale for each MR sequence. After scoring T2/DWI and T2/DWI/DCE-MRI, every lesion was graded based on its probability for malignancy. The inter-observer reliability was evaluated using Kappa statistics (Κ). Results: With respect to T2-weighted images, DWI and DCE-MRI Κ was 0.49, 0.97, and 0.77, respectively. Combined scoring of T2-weighted images and DWI demonstrated correct tumor diagnosis (true positive) in 71 - 88 % (depending on reader) of cases (Κ = 0.78). The accuracy was further improved to 88 - 96 % after scoring all three MR sequences including DCE-MRI (Κ = 0.90). Conclusion: The use of a simple 5-point scoring system for T2-weighted images, DWI, and DCE-MRI is feasible in functional prostate MRI and has high inter-observer reliability.

  14. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  15. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  16. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40......%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these...

  17. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    %), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these......Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40...

  18. An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs

    Science.gov (United States)

    Zachiu, C.; Papadakis, N.; Ries, M.; Moonen, C.; de Senneville, B. Denis

    2015-12-01

    Magnetic resonance (MR) guided high intensity focused ultrasound and external beam radiotherapy interventions, which we shall refer to as beam therapies/interventions, are promising techniques for the non-invasive ablation of tumours in abdominal organs. However, therapeutic energy delivery in these areas becomes challenging due to the continuous displacement of the organs with respiration. Previous studies have addressed this problem by coupling high-framerate MR-imaging with a tracking technique based on the algorithm proposed by Horn and Schunck (H and S), which was chosen due to its fast convergence rate and highly parallelisable numerical scheme. Such characteristics were shown to be indispensable for the real-time guidance of beam therapies. In its original form, however, the algorithm is sensitive to local grey-level intensity variations not attributed to motion such as those that occur, for example, in the proximity of pulsating arteries. In this study, an improved motion estimation strategy which reduces the impact of such effects is proposed. Displacements are estimated through the minimisation of a variation of the H and S functional for which the quadratic data fidelity term was replaced with a term based on the linear L1norm, resulting in what we have called an L2-L1 functional. The proposed method was tested in the livers and kidneys of two healthy volunteers under free-breathing conditions, on a data set comprising 3000 images equally divided between the volunteers. The results show that, compared to the existing approaches, our method demonstrates a greater robustness to local grey-level intensity variations introduced by arterial pulsations. Additionally, the computational time required by our implementation make it compatible with the work-flow of real-time MR-guided beam interventions. To the best of our knowledge this study was the first to analyse the behaviour of an L1-based optical flow functional in an applicative context: real-time MR

  19. Value of prostate specific antigen and prostatic volume ratio (PSA/V) as the selection criterion for US-guided prostatic biopsy

    International Nuclear Information System (INIS)

    Veneziano, S.; Paulica, P.; Querze', R.; Viglietta, G.; Trenta, A.

    1991-01-01

    US-guided biopsy was performed in 94 patients with suspected lesions at transerectal US. Histology demonstrated carcinoma in 43 cases, benign hyperplasia in 44, and prostatis in 7. In all cases the prostate specific antigen (PSA) was calculated, by means of US, together with prostatic volume (v). PSA was related to the corresponding gland volume, which resulted in PSA/V ratio. Our study showed PSA/V ration to have higher sensitivity and specificity than absolulute PSA value in the diagnosis of prostatic carcinoma. The authors believe prostate US-guided biopsy to be: a) necessary when the suspected area has PSA/V ratio >0.15, and especially when PSA/V >0.30; b) not indicated when echo-structural alterations are associated with PSA/V <0.15, because they are most frequently due to benign lesions. The combined use of PSA/V ratio and US is therefore suggested to select the patients in whom biopsy is to be performed

  20. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  1. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  2. Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments

    International Nuclear Information System (INIS)

    Nyholm, Tufve; Nyberg, Morgan; Karlsson, Magnus G; Karlsson, Mikael

    2009-01-01

    In the present work we compared the spatial uncertainties associated with a MR-based workflow for external radiotherapy of prostate cancer to a standard CT-based workflow. The MR-based workflow relies on target definition and patient positioning based on MR imaging. A solution for patient transport between the MR scanner and the treatment units has been developed. For the CT-based workflow, the target is defined on a MR series but then transferred to a CT study through image registration before treatment planning, and a patient positioning using portal imaging and fiducial markers. An 'open bore' 1.5T MRI scanner, Siemens Espree, has been installed in the radiotherapy department in near proximity to a treatment unit to enable patient transport between the two installations, and hence use the MRI for patient positioning. The spatial uncertainty caused by the transport was added to the uncertainty originating from the target definition process, estimated through a review of the scientific literature. The uncertainty in the CT-based workflow was estimated through a literature review. The systematic uncertainties, affecting all treatment fractions, are reduced from 3-4 mm (1Sd) with a CT based workflow to 2-3 mm with a MR based workflow. The main contributing factor to this improvement is the exclusion of registration between MR and CT in the planning phase of the treatment. Treatment planning directly on MR images reduce the spatial uncertainty for prostate treatments

  3. Robust adaptive extended Kalman filtering for real time MR-thermometry guided HIFU interventions.

    Science.gov (United States)

    Roujol, Sébastien; de Senneville, Baudouin Denis; Hey, Silke; Moonen, Chrit; Ries, Mario

    2012-03-01

    Real time magnetic resonance (MR) thermometry is gaining clinical importance for monitoring and guiding high intensity focused ultrasound (HIFU) ablations of tumorous tissue. The temperature information can be employed to adjust the position and the power of the HIFU system in real time and to determine the therapy endpoint. The requirement to resolve both physiological motion of mobile organs and the rapid temperature variations induced by state-of-the-art high-power HIFU systems require fast MRI-acquisition schemes, which are generally hampered by low signal-to-noise ratios (SNRs). This directly limits the precision of real time MR-thermometry and thus in many cases the feasibility of sophisticated control algorithms. To overcome these limitations, temporal filtering of the temperature has been suggested in the past, which has generally an adverse impact on the accuracy and latency of the filtered data. Here, we propose a novel filter that aims to improve the precision of MR-thermometry while monitoring and adapting its impact on the accuracy. For this, an adaptive extended Kalman filter using a model describing the heat transfer for acoustic heating in biological tissues was employed together with an additional outlier rejection to address the problem of sparse artifacted temperature points. The filter was compared to an efficient matched FIR filter and outperformed the latter in all tested cases. The filter was first evaluated on simulated data and provided in the worst case (with an approximate configuration of the model) a substantial improvement of the accuracy by a factor 3 and 15 during heat up and cool down periods, respectively. The robustness of the filter was then evaluated during HIFU experiments on a phantom and in vivo in porcine kidney. The presence of strong temperature artifacts did not affect the thermal dose measurement using our filter whereas a high measurement variation of 70% was observed with the FIR filter.

  4. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  5. MRI-guided biopsies and minimally invasive therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Sangeet Ghai

    2015-01-01

    Full Text Available Recent advances in multiparametric magnetic resonance imaging (mp-MRI have led to a paradigm shift in the diagnosis and management of prostate cancer (PCa. Its sensitivity in detecting clinically significant cancer and the ability to localize the tumor within the prostate gland has opened up discussion on targeted diagnosis and therapy in PCa. Use of mp-MRI in conjunction with prostate-specific antigen followed by targeted biopsy allows for a better diagnostic pathway than transrectal ultrasound (TRUS biopsy and improves the diagnosis of PCa. Improved detection of PCa by mp-MRI has also opened up opportunities for focal therapy within the organ while reducing the incidence of side-effects associated with the radical treatment methods for PCa. This review discusses the evidence and techniques for in-bore MRI-guided prostate biopsy and provides an update on the status of MRI-guided targeted focal therapy in PCa.

  6. MR-guided discography using an open 1 Tesla MRI system

    International Nuclear Information System (INIS)

    Streitparth, Florian; Bucourt, M. de; Hamm, B.; Teichgraeber, U.; Hartwig, T.; Strube, P.; Putzier, M.; Schnackenburg, B.; Chopra, S.

    2011-01-01

    To evaluate the feasibility of MR-guided discography using an open 1 Tesla MRI system. 48 disc segments of 41 patients scheduled for intradiscal thermal treatment, total disc replacement or spondylodesis were examined. A 1.0-T open MRI was used for instrument guidance and imaging. After primary disc puncture under guidance of interactive PDw TSE imaging, 1-2 ml of gadolinium contrast saline mixture was injected into the disc. The occurrence of memory pain during injection was recorded. Axial and sagittal T1w TSE images with and without fat saturation were obtained. All MRI discograms were analysed by two readers, who were blinded to the clinical findings. Overall, the placement of the puncture needle in the targeted disc was accurate under real-time MR guidance. Injections were technically successful in all cases. No major complications occurred. The mean procedure time was 17 min (range 13-34 min). Image quality of contrast-enhanced MR discograms was excellent when using an optimized gadolinium contrast saline mixture of 1:600. Memory pain was detected in 16 out of 48 affected segments. MR-guided discography is accurate and safe. Multiplanar dynamic imaging facilitates the puncture of discs and provides high-quality MR discograms. (orig.)

  7. Diagnosis of prostate cancer in patients with persistently elevated PSA and tumor-negative biopsy in ambulatory care. Performance of MR imaging in a multi-reader environment

    International Nuclear Information System (INIS)

    Scheidler, J.; Weoeres, I.; Scharf, M.; Siebels, M.; Brinkschmidt, C.; Zeitler, H.; Heuck, A.; Panzer, S.

    2012-01-01

    Purpose: False-negative results are obtained in approx. 20 % of prostate cancer (PCa) patients (pts) at initial systematic transrectal biopsy (Bx), in particular when digital rectal examination (DRE) or transrectal ultrasound (TRUS) is negative. The aim of this study was to assess whether MR endorectal imaging of the prostate in a multi-reader ambulatory care setting may assist in patient selection for re-biopsy. Materials and Methods: 115 consecutive pts with persistent PSA elevation, negative Bx, DRE and TRUS were examined using T2w axial and coronal and T1w axial sequences for tumor diagnosis. MR images were prospectively read as tumor-suspicious or tumor-negative by the MR radiologist on duty. Additionally, a retrospective readout of a prostate MR expert and an abdominal imaging fellowship-trained radiologist was performed to evaluate the effect of the reader's experience on tumor detection. Imaging findings were compared to the results of the repeat Bx (61 pts) or the clinical course of at least two years. Results: For the prospective reading, the sensitivity of MRI was 83 %, the specificity was 69 %, the PPV was 33 % and the NPV was 96 %. ROC analysis revealed a significantly better performance of the prostate MR imaging expert compared to the abdominal imaging radiologist (area under ROC 0.88 vs. 0.66, p < 0.001). Based on the prospective reading, a pre-test probability for PCa of 17.4 % as in our study can be reduced to 5 % when obtaining a tumor-negative result in MRI. Conclusion: MR imaging in a multi-reader ambulatory care setting assists in patient selection for re-biopsy. Reducing the post-test probability for PCa to 5 % allows for further follow-up instead of re-biopsy in MR tumor-negative patients. Specific training and experience improve tumor detection in prostate MR imaging. (orig.)

  8. Diagnosis of prostate cancer in patients with persistently elevated PSA and tumor-negative biopsy in ambulatory care. Performance of MR imaging in a multi-reader environment

    Energy Technology Data Exchange (ETDEWEB)

    Scheidler, J. [Radiologisches Zentrum Muenchen-Pasing, Muenchen (Germany); Weoeres, I.; Scharf, M.; Siebels, M. [Urologische Gemeinschaftspraxis Pasing (Germany); Brinkschmidt, C. [Gemeinschaftspraxis Pathologie, Starnberg (Germany); Zeitler, H.; Heuck, A. [Radiologisches Zentrum Muenchen (Germany); Panzer, S. [Unfallklinik Murnau (Germany). Radiologie

    2012-02-15

    Purpose: False-negative results are obtained in approx. 20 % of prostate cancer (PCa) patients (pts) at initial systematic transrectal biopsy (Bx), in particular when digital rectal examination (DRE) or transrectal ultrasound (TRUS) is negative. The aim of this study was to assess whether MR endorectal imaging of the prostate in a multi-reader ambulatory care setting may assist in patient selection for re-biopsy. Materials and Methods: 115 consecutive pts with persistent PSA elevation, negative Bx, DRE and TRUS were examined using T2w axial and coronal and T1w axial sequences for tumor diagnosis. MR images were prospectively read as tumor-suspicious or tumor-negative by the MR radiologist on duty. Additionally, a retrospective readout of a prostate MR expert and an abdominal imaging fellowship-trained radiologist was performed to evaluate the effect of the reader's experience on tumor detection. Imaging findings were compared to the results of the repeat Bx (61 pts) or the clinical course of at least two years. Results: For the prospective reading, the sensitivity of MRI was 83 %, the specificity was 69 %, the PPV was 33 % and the NPV was 96 %. ROC analysis revealed a significantly better performance of the prostate MR imaging expert compared to the abdominal imaging radiologist (area under ROC 0.88 vs. 0.66, p < 0.001). Based on the prospective reading, a pre-test probability for PCa of 17.4 % as in our study can be reduced to 5 % when obtaining a tumor-negative result in MRI. Conclusion: MR imaging in a multi-reader ambulatory care setting assists in patient selection for re-biopsy. Reducing the post-test probability for PCa to 5 % allows for further follow-up instead of re-biopsy in MR tumor-negative patients. Specific training and experience improve tumor detection in prostate MR imaging. (orig.)

  9. Three-dimensional proton MR spectroscopy of human prostate at 3 T without endorectal coil: feasibility.

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Heijmink, S.W.T.P.J.; Roell, S.A.; Hulsbergen-van de Kaa, C.A.; Knipscheer, B.C.; Witjes, J.A.; Barentsz, J.O.; Heerschap, A.

    2007-01-01

    PURPOSE: To evaluate sensitivity and specificity of proton magnetic resonance (MR) spectroscopy of the prostate with external surface coil elements at 3 T for differentiation of cancer from healthy tissue within an acceptable measurement time, by using histopathologic findings as the reference

  10. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    Energy Technology Data Exchange (ETDEWEB)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep [Uludag University Medical Faculty, Goeruekle Kampusu, Department of Radiology, Bursa (Turkey)

    2010-06-15

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  11. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep

    2010-01-01

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  12. MR imaging - guided corticosteroid-infiltration of the sacroiliac joints: pain therapy of sacroiliitis in patients with ankylosing spondylitis; Magnetresonanzgesteuerte Kortikosteroid-Infiltration der Sakroiliakalgelenke: Schmerztherapie der Sakroiliitis bei Patienten mit Spondylitis ankylosans

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Koenig, C.W.; Clasen, S.; Claussen, C.D.; Pereira, P.L. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Guenaydin, I.; Koetter, I. [Medizinische Klinik und Poliklinik II, Rheumaambulanz, Eberhard-Karls-Univ. Tuebingen (Germany); Kastler, B. [Univ. de Franche Comte, CHU Minjoz, Besancon (France)

    2005-04-01

    Purpose: To evaluate the efficacy and specific properties of MR imaging-guided corticosteroid infiltration of the sacroiliac (SI) joints in the treatment of therapy-refractory sacroiliitis in patients with ankylosing spondylitis. Materials and Methods: In this study, 26 patients were prospectively included. Inclusion criteria were AS with therapy refractory acute sacroiliitis and inflammatory back pain {>=} 6 months. The intervention was performed using an open low-field MR-scanner. Inflammatory back pain was assessed on a visual analog scale (VAS). Success of the therapy was defined as an absolute reduction of the VAS score {<=} 5, a relative reduction of the VAS score {>=} 35% and persisting improvement {>=} 2 months. The grade of sacroiliitis was documented using high-field MR imaging. Variables were compared using McNemar test and Wilcoxon test. The mean remission time was calculated using a Kaplan-Meier analysis. A p-value < 0.05 was considered statistically significant. Results: The intervention was technically successfully performed in all patients. Following MR imaging-guided corticosteroid infiltration of the SI joints, the VAS score improved from 8 (5-10) points to 4.5 (0-8) points(-44%) in all patients (n=26), which was statistically significant (p<0.001). Of 26 patients, 22 (85%) fulfilled the predefined criteria for successful therapy. This group had a statistically significant (p<0.01) improvement of the VAS score from 8 (6-10) to 3 (0-5) (-63%). Improvement was seen after 7 (1-30) days. There was a marked reduction of the subchondral bone marrow edema (-38%). The mean remission time was 12 (4-18) months. Conclusion: MR imaging-guided corticosteroid infiltration of the SI joints proved to be an effective therapy of inflammatory back pain in patients with therapy refractory AS. With the ability of multiplanar imaging, precise localization of the bone marrow edema and the lack of ionizing radiation, interventional MR imaging currently represents the

  13. WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de

  14. Technique development of 3D dynamic CS-EPSI for hyperpolarized 13 C pyruvate MR molecular imaging of human prostate cancer.

    Science.gov (United States)

    Chen, Hsin-Yu; Larson, Peder E Z; Gordon, Jeremy W; Bok, Robert A; Ferrone, Marcus; van Criekinge, Mark; Carvajal, Lucas; Cao, Peng; Pauly, John M; Kerr, Adam B; Park, Ilwoo; Slater, James B; Nelson, Sarah J; Munster, Pamela N; Aggarwal, Rahul; Kurhanewicz, John; Vigneron, Daniel B

    2018-03-25

    The purpose of this study was to develop a new 3D dynamic carbon-13 compressed sensing echoplanar spectroscopic imaging (EPSI) MR sequence and test it in phantoms, animal models, and then in prostate cancer patients to image the metabolic conversion of hyperpolarized [1- 13 C]pyruvate to [1- 13 C]lactate with whole gland coverage at high spatial and temporal resolution. A 3D dynamic compressed sensing (CS)-EPSI sequence with spectral-spatial excitation was designed to meet the required spatial coverage, time and spatial resolution, and RF limitations of the 3T MR scanner for its clinical translation for prostate cancer patient imaging. After phantom testing, animal studies were performed in rats and transgenic mice with prostate cancers. For patient studies, a GE SPINlab polarizer (GE Healthcare, Waukesha, WI) was used to produce hyperpolarized sterile GMP [1- 13 C]pyruvate. 3D dynamic 13 C CS-EPSI data were acquired starting 5 s after injection throughout the gland with a spatial resolution of 0.5 cm 3 , 18 time frames, 2-s temporal resolution, and 36 s total acquisition time. Through preclinical testing, the 3D CS-EPSI sequence developed in this project was shown to provide the desired spectral, temporal, and spatial 5D HP 13 C MR data. In human studies, the 3D dynamic HP CS-EPSI approach provided first-ever simultaneously volumetric and dynamic images of the LDH-catalyzed conversion of [1- 13 C]pyruvate to [1- 13 C]lactate in a biopsy-proven prostate cancer patient with full gland coverage. The results demonstrate the feasibility to characterize prostate cancer metabolism in animals, and now patients using this new 3D dynamic HP MR technique to measure k PL , the kinetic rate constant of [1- 13 C]pyruvate to [1- 13 C]lactate conversion. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Detection of prostate cancer with MR spectroscopic imaging: an expanded paradigm incorporating polyamines

    Energy Technology Data Exchange (ETDEWEB)

    Shukla-Dave, A.; Hricak, H.; Moskowitz, C.; Ishill, N.; Akin, O.; Kuroiwa, K.; Spector, J.; Kumar, M.; Reuter, V.E.; Koutcher, J.A.; Zakian, K.L. [Memorial Sloan-Kettering Cancer Center, New York, NY (United States). Dept. of Medical Physics

    2007-11-15

    Purpose: To characterize benign and malignant prostate peripheral zone (PZ) tissue retrospectively by using a commercial magnetic resonance (MR) spectroscopic imaging package and incorporating the choline plus creatine-to-citrate ratio ([Cho + Cr]/Cit) and polyamine (PA) information into a statistically based voxel classification procedure. Materials and methods: The institutional review board approved this HIPAA-compliant study and waived the requirement for informed consent. Fifty men (median age, 60 years; range, 44-69 years) with untreated biopsy-proved prostate cancer underwent combined endorectal MR imaging and MR spectroscopic imaging. Commercial software was used to acquire and process MR spectroscopic imaging data. The (Cho + Cr)/Cit and the PA level were tabulated for each voxel. The PA level was scored on a scale of 0 (PA undetectable) to 2 (PA peak as high as or higher than Cho peak). Whole-mount step-section histopathologic analysis constituted the reference standard. Classification and regression tree analysis in a training set generated a decision-making tree (rule) for classifying voxels as malignant or benign, which was validated in a test set. Receiver operating characteristic and generalized estimating equation regression analyses were used to assess accuracy and sensitivity, respectively. Results: The median (Cho + Cr)/Cit was 0.55 (mean {+-} standard deviation, 0.59 {+-} 0.03) in benign and 0.77 (mean, 1.08 {+-} 0.20) in malignant PZ voxels (P = .027). A significantly higher percentage of benign (compared with malignant) voxels had higher PA than choline peaks (P < .001). In the 24-patient training set (584 voxels), the rule yielded 54% sensitivity and 91% specificity for cancer detection; in the 26-patient test set (667 voxels), it yielded 42% sensitivity and 85% specificity. The percentage of cancer in the voxel at histopathologic analysis correlated positively (P < .001) with the sensitivity of the classification and regression tree rule

  16. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Fenster, Aaron; Ward, Aaron D

    2018-03-01

    Magnetic resonance imaging (MRI)-targeted, three-dimensional (3D) transrectal ultrasound (TRUS)-guided prostate biopsy aims to reduce the 21-47% false-negative rate of clinical two-dimensional (2D) TRUS-guided systematic biopsy, but continues to yield false-negative results. This may be improved via needle target optimization, accounting for guidance system errors and image registration errors. As an initial step toward the goal of optimized prostate biopsy targeting, we investigated how needle delivery error impacts tumor sampling probability for two targeting strategies. We obtained MRI and 3D TRUS images from 49 patients. A radiologist and radiology resident assessed these MR images and contoured 81 suspicious regions, yielding tumor surfaces that were registered to 3D TRUS. The biopsy system's root-mean-squared needle delivery error (RMSE) and systematic error were modeled using an isotropic 3D Gaussian distribution. We investigated two different prostate tumor-targeting strategies using (a) the tumor's centroid and (b) a ring in the lateral-elevational plane. For each simulation, targets were spaced at equal arc lengths on a ring with radius equal to the systematic error magnitude. A total of 1000 biopsy simulations were conducted for each tumor, with RMSE and systematic error magnitudes ranging from 1 to 6 mm. The difference in median tumor sampling probability and probability of obtaining a 50% core involvement was determined for ring vs centroid targeting. Our simulation results indicate that ring targeting outperformed centroid targeting in situations where systematic error exceeds RMSE. In these instances, we observed statistically significant differences showing 1-32% improvement in sampling probability due to ring targeting. Likewise, we observed statistically significant differences showing 1-39% improvement in 50% core involvement probability due to ring targeting. Our results suggest that the optimal targeting scheme for prostate biopsy depends on

  17. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS

    NARCIS (Netherlands)

    Futterer, J.J.; Moche, M.; Busse, H.; Yakar, D.

    2016-01-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and

  18. MR imaging of prostatic neoplasms with and without Gd-DTPA as intravenous contrast agent

    International Nuclear Information System (INIS)

    Schmidt, H.; Beer, M.; Schnabl, G.; Hahn, D.; Naegele, M.

    1986-01-01

    Nine patients with prostatic carcinoma (proved by radical prostatectomy in five and by TUR in four), five patients with benign prostatic hyperplasia (BPH, proved by adenomectomy in two and by TUR in three) and three control subjects underwent MR imaging performed using the Siemens Magnetom (1.0T) and the spin echo sequences 1.6/30,90,0.5/30, and 0.2/20 msec prior to, and the sequences 0.5/30 and 0.2/20 after, administration of Gd-DTPA (0.2 mmol/kg). The normal prostate showed a low, homogeneous signal enhancement. In BPH, the signal enhancement of the adenoma varied widely. In three of the five patients the adenoma was better demarcated from the pseudocapsule after administration of Gd-DTPA than on the precontrast image. The prostatic carcinoma showed only slightly less signal enhancement than BPH. On the postcontrast image, six of the nine carcinomas were visualized as a hyperintense nodule. However, reliable differentiation of prostatic carcinoma from BPH by means of signal enhancement was not possible

  19. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Gao, Q.H.; Xie, H.; Nelson, D.F.; Yu, Y.; Kwok, W.E.; Totterman, S.; Schell, M.C.; Rubin, P.

    1996-01-01

    and marrow information within the skull. Next, a ray-tracing method is used to generate a projection (pseudo-portal) image at the planned treatment position. In this situation, the ray-tracing is simply performed on pixels rather than attenuation coefficients. The skull and its relative positions are also projected to the pseudo-portal image and are used as 'hint' for the search of similar features in the portal images. A Canny edge detector is applied to the region of treatment field and is used to enhance brain contour and skull. The skull in the brain is then identified using a snake technique which is guided by the ''hint'', the projected features from MR images. Finally, a Chamfer matching technique is used to correlate features between the MR projection and portal images. Results: MR image-guided portal verification technique is evaluated using a clinical patient case who has an astrocytoma brain tumor and is treated by radiation therapy. The segmented results for brain MR slice images indicate that a wavelet-based image segmentation technique provides a reasonable estimation for the brain skull. Compared to the brain portal image, the method developed in this study for the generation of brain projection images provides skull structure about 3 mm differences. However, overall matching results are within 2 mm compared to the results between portal and simulation images. In addition, tumor volume can be accurately visualized in the projection image and be mapped over to portal images for treatment verification with this approach. Conclusions: A method for MR image-guided portal verification of brain treatment field is being developed. Although the projection image from MR images dose not have the similar radiographic appearance as portal images, it provides certain essential anatomical features (landmarks and gross tumor) as well as their relative locations to be used as references for computerized portal verification

  20. Urinary morbidity following ultrasound-guided transperineal prostate seed implantation

    International Nuclear Information System (INIS)

    Gelblum, Daphna Y.; Potters, Louis; Ashley, Richard; Waldbaum, Robert; Wang Xiaohong; Leibel, Steven

    1999-01-01

    Purpose: To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Methods and Materials: Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125 I in 165 patients and with 103 Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125 I (pre TG43) or 120 Gy with 103 Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA ≥ 10 and/or Gleason score ≥ 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125 I or 103 Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of

  1. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  2. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  3. Image-guided diagnosis of prostate cancer can increase detection of tumors

    Science.gov (United States)

    In the largest prospective study to date of image-guided technology for identifying suspicious regions of the prostate to biopsy, researchers compared the ability of this technology to detect high-risk prostate cancer with that of the current standard of

  4. A new image navigation system for MR-guided cryosurgery

    International Nuclear Information System (INIS)

    Mogami, Takuji; Dohi, Michiko; Harada, Junta

    2002-01-01

    The purpose of this study was to evaluate the feasibility of Interactive Scan Control (ISC), a new MR image navigation system, during percutaneous puncture in cryosurgery. With the ISC system in place, percutaneous MR-guided cryosurgery was performed in 26 cases, with the ISC system being used in 11 cases (five renal tumors, three uterine fibroids and three metastatic liver tumors). The ISC system comprised infrared cameras and an MR-compatible optical tracking tool that was directly connected to a cryoprobe. Tumor sizes ranged from 1.2 cm (metastatic liver tumor) to 9.0 cm (uterine fibroid), for a mean size of 3.9 cm. With ISC, one to three cryoprobes with a diameter of 2 mm or 3 mm were advanced into the tumors with the guidance of an MR fluoroscopic image. Two freeze-thaw cycles were used for cryosurgery. During the cryosurgery, the formation of iceballs was monitored on MR images. Follow-up dynamic CT or MRI as well as physical examinations were conducted after two weeks and six weeks. Placement of probes was successfully performed under the control of the ISC system. During cryosurgery, engulfment of the tumors by iceballs was carefully monitored by MRI. Necrosis of the cryoablated area was confirmed in all renal tumors by follow-up dynamic CT. The size regression of the uterine fibroids was observed through follow-up MRI. Two of the three cases of metastatic liver tumor were ablated completely. Additional therapy for a residual tumor was performed on one patient with a metastatic liver tumor. A small amount of pneumothorax was the only complication found in a patient with a metastatic liver tumor. MR-guided cryosurgery with this new navigation system was feasible with low morbidity and allowed for safe and accurate puncture with a cryoprobe. (author)

  5. Advances in MRI diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Zhang Longmin; Liu Ailian

    2014-01-01

    Prostate cancer is the second most common cancer in the world, and the incidence of prostate cancer in China shows an upward trend. MRI has high soft tissue resolution and multi-dimensional imaging advantages, and it can better show the anatomy of the prostate and adjacent tissue structures. With the development of MR technique, it plays a more and more important role in prostate cancer diagnosis. This review starts from the imaging performance of routine MRI sequence of prostate cancer, and a variety of functional MRI applications in the diagnosis and differential diagnosis of prostate cancer are described in detail, such as MR perfusion-weighted imaging, MR spectroscopy, MR diffusion-weighted imaging, MR diffusion tensor imaging, intravoxel incoherent motion diffusion-weighted imaging, MR susceptibility-weighted imaging. Meanwhile this review introduces that functional MRI has more advantages and can provide more image information than routine MRI sequence. According to a series of semi-quantitative and quantitative data, functional MRI can further provide the blood perfusion of prostate cancer, water molecule diffusion and microcirculation state, metabolism and biochemical composition change information. (authors)

  6. Transperineal template-guided prostate saturation biopsies in men with suspicion of prostate cancer: a pilot study from Pakistan.

    Science.gov (United States)

    Mehmood, K; Mubarak, M; Dhar, M; Rafi, M; Kinsella, J

    2017-12-01

    Traditionally, transrectal ultrasound (TRUS)-guided biopsies are done for the diagnosis of prostate cancer (PCa) in Pakistan. The transperineal template-guided saturation biopsy (TTSB) approach has been recently introduced in Pakistan and we share diagnostic yields and pathological findings of specimens taken for PCa diagnosis in men with elevated serum total prostate specific antigen (PSA) and negative TRUS-guided prostate biopsies. In all, 16 patients investigated at the Department of Urology, Sindh Institute of Urology and Transplantation (SIUT), underwent TTSB. The mean age of patients was 67.8 ± 8.8 (range: 55 - 84) years. The median PSA was 9.5 (IQR: 7.9 - 19.8) ng/ ml. The duration of symptoms before biopsy ranged from 1 month to 144 months. The prostate was enlarged with mean weight of 73.5 ± 55.5 g. Histopathology revealed PCa in 5 of 16 (31.2%) cases. The Gleason score was 6 (3+3), 7 (3+4) and 8 (4+4) in 1 case each (6.3%) and 10 (5+5) in 2 cases (12.5%). At least two cores were positive in all positive cases. None of the patients required antibiotics post-procedure. In conclusion, the TTSB technique is a promising option for patients with elevated PSA level and negative transrectal prostate biopsies for the detection of PCa in our setting.

  7. Experimental MR-guided cryotherapy of the brain with almost real-time imaging by radial k-space scanning; Experimentelle MR-gesteuerte Kryotherapie des Gehirns mit nahezu Echtzeitdarstellung durch radiale k-Raum-Abtastung

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J.; Schorn, R.; Glowinski, A.; Grosskortenhaus, S.; Adam, G.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Speetzen, R.; Rau, G. [Helmholtz-Institut fuer Biomedizinische Technik, Aachen (Germany); Rasche, V. [Philips GmbH Forschungslaboratorium, Hamburg (Germany)

    1999-02-01

    Purpose: To test radial k-space scanning by MR fluoroscopy to guide and control MR-guided interstitial cryotherapy of the healthy pig brain. Methods: After MR tomographic planning of the approach, an MR-compatible experimental cryotherapy probe of 2.7 mm diameter was introduced through a 5 mm burr hole into the right frontal brain of five healthy pigs. The freeze-thaw cycles were imaged using a T{sub 1}-weighted gradient echo sequence with radial k-space scanning in coronal, sagittal, and axial directions. Results: The high temporal resolution of the chosen sequence permits a continuous representation of the freezing process with good image quality and high contrast between ice and unfrozen brain parenchyma. Because of the interactive conception of the sequence the layer plane could be chosen as desired during the measurement. Ice formation was sharply demarcated, spherically configurated, and was free of signals. Its maximum diameter was 13 mm. Conclusions: With use of the novel, interactively controllable gradient echo sequence with radial k-space scanning, guidance of the intervention under fluoroscopic conditions with the advantages of MRT is possible. MR-guided cryotherapy allows a minimally-invasive, precisely dosable focal tissue ablation. (orig.) [Deutsch] Ziel: Erprobung der radialen k-Raum-Abtastung bei der MR-Fluoroskopie zur Steuerung und Kontrolle MR-gesteuerter interstitieller Kryotherapie des gesunden Schweinegehirns. Methoden: Nach MR-tomographischer Planung des Zugangsweges wurde eine MR-kompatible experimentelle Kryotherapiesonde von 2,7 mm Durchmesser ueber ein 5 mm Bohrloch in das rechte Frontalhirn von fuenf gesunden Schweinen eingebracht. Die Frier-/Tauzyklen wurden anhand einer T{sub 1}-gewichteten Gradientenechosequenz mit radialer k-Raum-Abtastung in koronarer, sagittaler und axialer Schichtfuehrung dargestellt. Ergebnisse: Die hohe zeitliche Aufloesung der gewaehlten Sequenz erlaubte eine kontinuierliche Darstellung des Friervorgangs bei

  8. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  9. Non-granulomatous prostatitis: MR appearance with an endorectal surface coil; Nichtgranulomatoese Prostatitis: Erscheinungsbild im MRT mit endorektaler Oberflaechenspule (``Endo-MRT``)

    Energy Technology Data Exchange (ETDEWEB)

    Szolar, D.H.M. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Ranner, G. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Preidler, K.W. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Lax, S. [Inst. fuer Pathologische Anatomie, Univ. Graz (Austria)

    1995-01-01

    Inflammatory conditions of the prostate are often idfficult to distinguish from early stages of prostate cancer with imaging techniques. The use of an endorectal surface coil in MRI of the prostate gland has been reported to provide superior resolution and better imaging of details than MRI with a body coil in the diagnosis of early prostate cancer. We report a 34-year-old patient with nonspecific non-granlomatous prostatitis in whom T{sub 2}-weighted endorectal surface coil magnetic resonance imaging (ESCMRI) showed a region of markedly decreased signal intensity in the periphery of the gland. The low signal intensity of the lesion, its sharp demarcation from the normal part of the peripheral zone of the prostate and the marked bulge of the surface contour without capsular breach of the organ were interpreted as evidence of a bioptically proven benign inflammatory condition. (orig.) [Deutsch] Die Unterscheidung entzuendlicher Prozesse von Fruehstadien maligner Neoplasien der Prostata mittels Magnetresonanztomographie bereitet immer wieder Schwierigkeiten. Die Anwendung einer Oberflaechenspule erlaubt durch hoehere Aufloesung eine exaktere Beurteilung der Prostatakapsel, was eine hoehere Treffsicherheit beim Nachweis moeglicher organueberschreitender Infiltrationen bedeutet. Wir praesentieren den Fall eines 34jaehrigen Mannes mit unspezifischer, nichtgranulomatoeser Prostatitis, bei dem das MR-Tomogramm mit endorektal plazierter Oberflaechenspule (Endo-MRT) in der Peripherzone ein Areal deutlich herabgesetzter Signalintensitaet auf T{sub 2}-gewichteten Aufnahmen zeigte. Die scharfe Begrenzung der ausgedehnten signalarmen Laesion gegenueber dem nichtbefallenen Anteil der Peripherzone beim im Endo-MRT identifizierbarer intakter Kapsel liess ein organueberschreitendes Malignom ausschliessen und bestaetigte durch histologische Aufarbeitung der Bioptate den Endo-MRT-Verdachtsbefund einer Prostatitis. (orig.)

  10. Acute bacterial prostatitis after transrectal ultrasound-guided prostate biopsy: epidemiological, bacteria and treatment patterns from a 4-year prospective study.

    Science.gov (United States)

    Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre

    2014-02-01

    To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.

  11. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    Science.gov (United States)

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  12. Noninvasive MR-Guided HIFU Therapy of TSC-Associated Renal Angiomyolipomas

    Science.gov (United States)

    2014-09-01

    sufficient for this application because coil array configuration is limited by small mouse anatomy. In our third year’s effort, the research plan was...therapy and a new Ingenia 1.5 Tesla MRI scanner from Philips HealthCare. Using the new instrumentation, we established a large animal MR-guided HIFU...anatomy limitation in mice MRI coil development, mouse cancer model was not used eventually. In the third year, we developed a large animal MR

  13. MR-guided facet joint injection therapy using an open 1.0-T MRI system: an outcome study

    International Nuclear Information System (INIS)

    Freyhardt, Patrick; Bucourt, Maximilian de; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Streitparth, Florian; Hartwig, Tony; Teichgraeber, Ulf K.M.

    2013-01-01

    To evaluate the accuracy, safety and efficacy of magnetic resonance imaging (MRI)-guided facet joint injection therapy using a 1.0-T open MRI. One hundred and sixty-six facet joint blocks in 45 patients with lower back pain were performed under MR fluoroscopic guidance using a proton-density-weighted turbo-spin-echo sequence. An in-room monitor, wireless MR-mouse for operator-controlled multiplanar navigation, a flexible surface coil and MR-compatible 20-G needle were used. Clinical outcome was evaluated by questionnaire before intervention and after 1 week, 3, 6 and 12 months using a numerical visual analogue scale (VAS). All facet joint blocks were considered technically successful with distribution of the injectant within and/or around the targeted facet joint. No major complications occurred. The final outcome analysis included 38 patients. An immediate effect was reported by 63 % of the patients. A positive mid-/long-term effect was seen in 13 patients (34 %) after 6 months and in 9 patients (24 %) after 12 months. Mean VAS was reduced from 7.1 ± 1.7 (baseline) to 3.5 ± 2.2, 4.1 ± 3.0, 3.8 ± 2.9 and 4.6 ± 2.9 at 1 week, 3, 6 and 12 months (P < 0.01). MR-guided facet joint injection therapy of the lumbosacral spine is accurate, safe and efficient in the symptomatic treatment of lower back pain. (orig.)

  14. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaofeng, E-mail: xyang43@emory.edu; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Curran, Walter J.; Liu, Tian [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia 30322 (United States); Mao, Hui [Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia 30322 (United States)

    2014-11-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  15. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Science.gov (United States)

    Yang, Xiaofeng; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2014-01-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  16. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  17. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de [University Hospital of Cologne, Department of Diagnostic and Interventional Radiology (Germany); Pech, Maciej [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany); Lux, Anke [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics (Germany); Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany)

    2017-06-15

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

  18. Comparative study of conventional US, contrast enhanced US and enhanced MR for the follow-up of prostatic radiofrequency ablation.

    Science.gov (United States)

    Feng, Chao; Hu, Bin; Hu, Bing; Chen, Lei; Li, Jia; Huang, Jin

    2017-06-01

    The aim of the present study was to evaluate and compare the effectiveness of different imaging methods during follow-up of prostatic radiofrequency ablation. Prostatic radiofrequency ablation (RFA) was performed in 20 healthy beagle dogs. Various imaging examinations were used to monitor the results of RFA, including conventional ultrasound (US), contrast enhanced ultrasound (CEUS) and enhanced magnetic resonance (MR). Imaging exams were performed at five phases: Immediately following RFA, one week later, one month later, three months later and six months later. The morphology for each imaging test and histological results were recorded and compared in each phase. Based on the actual results from autopsy, the accuracy of those imaging exams was evaluated. The canine prostate gland demonstrated typical coagulative necrosis immediately following RFA. The lesion would develop into stable cyst if no other complications occurred within the six-month follow-up. Regarding the RFA lesion volume measurement and the reflection of pathological changes, conventional US was not able to accurately measure the volume of RFA lesion and missed many more details concerning the RFA-treated area than CEUS and MR during the three months. The results from CEUS exhibited comparable accuracy to those from enhanced MR at each phase. However, there were no significant differences in the results from US, CEUS and MR at six months, which may contribute to the complete formation of lesion cyst. In the early phase, conventional US was not sufficient for evaluating the efficacy of RFA. Enhanced US and MR provided clear images and accurate information. However, CEUS has the advantage of being more economical, using more convenient equipment and faster scanning, thus identifying it as the more feasible choice. Furthermore, no notable advantages were observed among any image examinations in the long-term follow-up.

  19. Multiparametric MRI of the prostate. Important radiological findings for urologists; Multiparametrische MRT der Prostata. Wichtige radiologische Befunde fuer den Urologen

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany)

    2017-08-15

    High prevalence of prostate cancer with multifocality and biological heterogeneity. Insufficient conventional urological diagnostics. Discrimination between significant and insignificant cancer needed. Digital rectal examination, prostate-specific antigen (PSA) serum level, systematic transrectal ultrasound (TRUS)-guided prostate biopsy. Multiparametric magnetic resonance imaging (mpMRI) including T2-weighted (T2w), diffusion-weighted and dynamic contrast-enhanced MRI according to the prostate imaging reporting and data system (PIRADS), MR-targeted biopsy, most frequently MR/TRUS image fusion biopsy. Prostate cancer is characterized by low signal intensity on T2w MRI, restricted water diffusion and pronounced and early uptake of contrast enhancement. Sensitivity and specificity according to the current literature are ca. 80% and 90%, respectively. In cases of suspected prostate cancer, most accurate are mpMRI according to PIRADS and in cases of positive findings, MRI-targeted biopsy, most frequently as MRI/TRUS image fusion biopsy. (orig.) [German] Hohe Praevalenz des Prostatakarzinoms mit Multifokalitaet und biologischer Heterogenitaet. Unzureichende konventionelle urologische Diagnostik. Unterscheidung klinisch signifikanter von klinisch nicht signifikanten Karzinomen erforderlich. Digitale rektale Untersuchung, Serum-PSA (prostataspezifisches Antigen), transrektale Sonographie (TRUS), systematische transrektale TRUS-Biopsie. Multiparametrische Magnetresonanztomographie (mpMRT) mit T2w- und diffusionsgewichteten sowie dynamischen kontrastmittelverstaerkten T1w-Sequenzen, dem Standard nach dem Prostate Imaging Reporting and Data System (PIRADS) entsprechend. MR-unterstuetzte Biopsie, meist MR-/TRUS-Fusionsbiopsie. Prostatakarzinome sind typischerweise T2-hypointens mit eingeschraenkter Diffusion und zeigen eine rasche Kontrastmittelanflutung. Nach der Literatur betragen Sensitivitaet und Spezifitaet der mpMRT ca. 80 bzw. 90 %. Fuer die Abklaerung bei Verdacht auf

  20. MR imaging-guided percutaneous cryotherapy for lung tumors: initial experience.

    Science.gov (United States)

    Liu, Shangang; Ren, Ruimei; Liu, Ming; Lv, Yubo; Li, Bin; Li, Chengli

    2014-09-01

    To evaluate prospectively the initial clinical experience of magnetic resonance (MR) imaging-guided percutaneous cryotherapy of lung tumors. MR imaging-guided percutaneous cryotherapy was performed in 21 patients with biopsy-proven lung tumors (12 men, 9 women; age range, 39-79 y). Follow-up consisted of contrast-enhanced chest computed tomography (CT) scan performed at 3-month intervals to assess tumor control; CT scanning was carried out for 12 months or until death. Cryotherapy procedures were successfully completed in all 21 patients. Pneumothorax occurred in 7 (33.3%) of 21 patients. Chest tube placement was required in one (4.8%) case. Hemoptysis was exhibited by 11 (52.4%) patients, and pleural effusion occurred in 6 (28.6%) patients. Other complications were observed in 14 (66.7%) patients. The mean follow-up period was 10.5 months (range, 9-12 mo) in patients who died. At month 12 of follow-up, 7 (33.3%) patients had a complete response to therapy, and 10 (47.6%) patients showed a partial response. In addition, two patients had stable disease, and two patients developed progressive disease; one patient developed a tumor in the liver, and the other developed a tumor in the brain. The 1-year local control rate was 81%, and 1-year survival rate was 90.5%. MR imaging-guided percutaneous cryotherapy appears feasible, effective, and minimally invasive for lung tumors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  1. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  2. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  3. Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.

    1997-01-01

    The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [de

  4. Granulomatous prostatitis: a pitfall in MR imaging of prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gevenois, P.A. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Stallenberg, B. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Sintzoff, S.A. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Salmon, I. [Dept. of Pathology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Regemorter, G. van [Dept. of Urology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Struyven, J. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium)

    1992-08-01

    Granulomatous prostatitis is an uncommon disease that can mimic prostatic carcinoma on both digital rectal examination and transrectal ultrasound. Four patients who underwent magnetic resonance imaging of the prostate had a histological diagnosis of granulomatous prostatitis; three of them had recent urinary tract infections. The other patient had an associated midline prostatic cyst and a focus of malignancy. T1- and T2-weighted spin-echo images were obtained in all cases. Peripheral zone lesions of decreased signal intensity, suggestive of carcinoma, were found in all four patients on T2-weighted images. Granulomatous prostatitis should be considered in the differential diagnosis of low signal intensity areas with prostatic magnetic resonance imaging. (orig.)

  5. Five-year follow-up using a prostate stent as fiducial in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Carl, Jesper; Sander, Lotte

    2015-06-01

    To report results from the five-year follow-up on a previously reported study using image-guided radiotherapy (IGRT) of localized or locally advanced prostate cancer (PC) and a removable prostate stent as fiducial. Patients with local or locally advanced PC were treated using five-field 3D conformal radiotherapy (3DRT). The clinical target volumes (CTV) were treated to 78 Gy in 39 fractions using daily on-line image guidance (IG). Late genito-urinary (GU) and gastro-intestinal (GI) toxicities were scored using the radiotherapy oncology group (RTOG) score and the common toxicity score of adverse events (CTC) score. Urinary symptoms were also scored using the international prostate symptom score (IPSS). Median observation time was 5.4 year. Sixty-two of the 90 patients from the original study cohort were eligible for toxicity assessment. Overall survival, cancer-specific survival and biochemical freedom from failure were 85%, 96% and 80%, respectively at five years after radiotherapy. Late toxicity GU and GI RTOG scores≥2 were 5% and 0%. Comparing pre- and post-radiotherapy IPSS scores indicate that development in urinary symptoms after radiotherapy may be complex. Prostate image-guided radiotherapy using a prostate stent demonstrated survival data comparable with recently published data. GU and GI toxicities at five-year follow-up were low and comparable to the lowest toxicity rates reported. These findings support that the precision of the prostate stent technique is at least as good as other techniques. IPSS revealed a complex development in urinary symptoms after radiotherapy.

  6. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  7. The study of diagnostic efficacy of MR spectroscopy in prostate cancer

    International Nuclear Information System (INIS)

    Ye Jintang; Guo Xuemei; Wang Xiaoying; Li Feiyu; Jiang Xuexiang

    2009-01-01

    Objective: To evaluate the diagnostic efficacy of MRS in prostate cancer based on sextant localization. Methods: There were 110 patients, 54 patients with pathologically confirmed prostate cancer and 56 patients confirmed non-prostate cancer proved by ultrasound guided systemic biopsy. The (choline + creatine) / citrate (CC/C) value in each voxel and ratio of positive voxel (PVR) in sextant localization were measured. The ROC analysis was used to evaluate the diagnostic efficacy of CC/C in single voxel and PVR in sextant localization. Results: There are 1673 and 2426 voxel in prostate cancer and non-prostate cancer respectively. The median of CC/C in cancer sextants was 2.137; the median of CC/C in noncancer sextants was 0.600. The difference of these two groups was statistically significant (Z = -41.7, P < 0.01). The diagnostic sensitivity was 81.4% (1362/1673), the specificity was 83.1% (2018/2426), and the accuracy was 82.4% [(1362 + 2018)/4099] for prostatic cancer with the cutoff point 0.911 of the CC/C value. The median of PVR in cancer sextants and noncancer sextants were 1 and 0 respectively, the difference of PVR was statistically significant ( Z =-11.7, P < 0.01). The diagnostic sensitivity was 77.5% (148/191), the specificity was 76.9% (247/321), and the accuracy was 77.1%[(148 + 247)/512] for prostatic cancer with the cutoff point 0.519 of the PVR. Conclusion: Detecting the cutoff point of the CC/C value in single voxel and the PVR in sextant localization may be valuable in the diagnosis of prostate cancer. (authors)

  8. Organ-confined prostate cancer: effect of prior transrectal biopsy on endorectal MRI and MR spectroscopic imaging

    International Nuclear Information System (INIS)

    Qayyum, Aliya; Coakley, F.V.; Lu, Y.; Olpin, J.D.; Wu, L.; Yeh, B.M.; Carroll, P.R.; Kurhanewicz, J.

    2004-01-01

    Objective: Our aim was to determine the effect of prior transrectal biopsy on endorectal MRI and MR spectroscopic imaging findings in patients with organ-confined prostate cancer. Materials and Methods: Endorectal MRI and MR spectroscopic imaging were performed in 43 patients with biopsy-proven prostate cancer before radical prostatectomy confirming organ-confined disease. For each sextant, two independent reviewers scored the degree of hemorrhage on a scale from 1 to 5 and recorded the presence or absence of capsular irregularity. A spectroscopist recorded the number of spectrally degraded voxels in the peripheral zone. The outcome variables of capsular irregularity and spectral degradation were correlated with the predictor variables of time from biopsy and degree of hemorrhage after biopsy. Results: Capsular irregularity was unrelated to time from biopsy or to degree of hemorrhage. Spectral degradation was inversely related to time from biopsy (p < 0.01); the mean percentage of degraded peripheral zone voxels was 18.5% within 8 weeks of biopsy compared with 7% after 8 weeks. Spectral degradation was unrelated to the degree of hemorrhage. Conclusion: In organ-confined prostate cancer, capsular irregularity can be seen at any time after biopsy and is independent of the degree of hemorrhage, whereas spectral degradation is seen predominantly in the first 8 weeks after biopsy. MRI staging criteria and guidelines for scheduling studies after biopsy may require appropriate modification. (author)

  9. Quantitative characterisation of clinically significant intra-prostatic cancer by prostate-specific membrane antigen (PSMA) expression and cell density on PSMA-11.

    Science.gov (United States)

    Domachevsky, Liran; Goldberg, Natalia; Bernstine, Hanna; Nidam, Meital; Groshar, David

    2018-05-30

    To quantitatively characterize clinically significant intra-prostatic cancer (IPC) by prostate-specific membrane antigen (PSMA) expression and cell density on PSMA-11 positron emission tomography/magnetic resonance (PET/MR). Retrospective study approved by the institutional review board with informed written consent obtained. Patients with a solitary, biopsy-proven prostate cancer, Gleason score (GS) ≥7, presenting for initial evaluation by PET/computerised tomography (PET/CT), underwent early prostate PET/MR immediately after PSMA-11 tracer injection. PET/MR [MRI-based attenuation correction (MRAC)] and PET/CT [CT-based AC (CTAC)] maximal standardised uptake value (SUVmax) and minimal and mean apparent diffusion coefficient (ADCmin, ADCmean; respectively) in normal prostatic tissue (NPT) were compared to IPC area. The relationship between SUVmax, ADCmin and ADCmean measurements was obtained. Twenty-two patients (mean age 69.5±5.0 years) were included in the analysis. Forty-four prostate areas were evaluated (22 IPC and 22 NPT). Median MRAC SUVmax of NPT was significantly lower than median MRAC SUVmax of IPC (p prostate cancer patients with GS ≥ 7. • PSMA PET/MR metrics differentiate between normal and tumoural prostatic tissue. • A multi-parametric approach combining molecular and anatomical information might direct prostate biopsy. • PSMA PET/MR metrics are warranted for radiomics analysis.

  10. The value of magnetic resonance imaging and ultrasonography (MRI/US)-fusion biopsy platforms in prostate cancer detection: a systematic review.

    Science.gov (United States)

    Gayet, Maudy; van der Aa, Anouk; Beerlage, Harrie P; Schrier, Bart Ph; Mulders, Peter F A; Wijkstra, Hessel

    2016-03-01

    Despite limitations considering the presence, staging and aggressiveness of prostate cancer, ultrasonography (US)-guided systematic biopsies (SBs) are still the 'gold standard' for the diagnosis of prostate cancer. Recently, promising results have been published for targeted prostate biopsies (TBs) using magnetic resonance imaging (MRI) and ultrasonography (MRI/US)-fusion platforms. Different platforms are USA Food and Drug Administration registered and have, mostly subjective, strengths and weaknesses. To our knowledge, no systematic review exists that objectively compares prostate cancer detection rates between the different platforms available. To assess the value of the different MRI/US-fusion platforms in prostate cancer detection, we compared platform-guided TB with SB, and other ways of MRI TB (cognitive fusion or in-bore MR fusion). We performed a systematic review of well-designed prospective randomised and non-randomised trials in the English language published between 1 January 2004 and 17 February 2015, using PubMed, Embase and Cochrane Library databases. Search terms included: 'prostate cancer', 'MR/ultrasound(US) fusion' and 'targeted biopsies'. Extraction of articles was performed by two authors (M.G. and A.A.) and were evaluated by the other authors. Randomised and non-randomised prospective clinical trials comparing TB using MRI/US-fusion platforms and SB, or other ways of TB (cognitive fusion or MR in-bore fusion) were included. In all, 11 of 1865 studies met the inclusion criteria, involving seven different fusion platforms and 2626 patients: 1119 biopsy naïve, 1433 with prior negative biopsy, 50 not mentioned (either biopsy naïve or with prior negative biopsy) and 24 on active surveillance (who were disregarded). The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to assess the quality of included articles. No clear advantage of MRI/US fusion-guided TBs was seen for cancer detection rates (CDRs) of all prostate

  11. MR-guided perineural injection of the ganglion impar: technical considerations and feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Marker, David R.; Carrino, John A.; Fritz, Jan [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Musculoskeletal Radiology, Baltimore, MD (United States); U-Thainual, Paweena [Queen' s University, Department of Mechanical and Materials Engineering, Kingston, ON (Canada); Ungi, Tamas; Fichtinger, Gabor [Queen' s University, School of Computing, Kingston, ON (Canada); Flammang, Aaron J. [Siemens Corporate Research, Center for Applied Medical Imaging, Baltimore, MD (United States); Iordachita, Iulian I. [Johns Hopkins University, Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Baltimore, MD (United States)

    2016-05-15

    Perineural ganglion impar injections are used in the management of pelvic pain syndromes; however, there is no consensus regarding the optimal image guidance. Magnetic resonance imaging (MRI) provides high soft tissue contrast and the potential to directly visualize and target the ganglion. The purpose of this study was to assess the feasibility of MR-guided percutaneous perineural ganglion impar injections. Six MR-guided ganglion impar injections were performed in six human cadavers. Procedures were performed with a clinical 1.5-Tesla MRI system through a far lateral transgluteus approach. Ganglion impar visibility, distance from the sacrococcygeal joint, number of intermittent MRI control steps required to place the needle, target error between the intended and final needle tip location, inadvertent punctures of non-targeted vulnerable structures, injectant distribution, and procedure time were determined. The ganglion impar was seen on MRI in 4/6 (66 %) of cases and located 0.8 mm cephalad to 16.3 mm caudad (average 1.2 mm caudad) to the midpoint of the sacrococcygeal joint. Needle placement required an average of three MRI control steps (range, 2-6). The average target error was 2.2 ± 2.1 mm. In 6/6 cases (100 %), there was appropriate periganglionic distribution and filling of the presacrococcygeal space. No punctures of non-targeted structures occurred. The median procedure time was 20 min (range, 12-29 min). Interventional MRI can visualize and directly target the ganglion impar for accurate needle placement and successful periganglionic injection with the additional benefit of no ionizing radiation exposure to patient and staff. Our results support clinical evaluation. (orig.)

  12. Protocol for the realization of transrectal prostatic biopsy guided by ultrasound

    International Nuclear Information System (INIS)

    Arce Montero, Jairo

    2013-01-01

    A general protocol is proposed for the realization of the ultrasound-guided prostatic biopsy in patients with positive screening. The screening should be performed taking into account risk antecedents, rectal examination and prostate-specific antigen (PSA) levels in the patients. However, patients that have presented without alteration in the PSA and suspect rectal examination, should be considered for biopsy endorectal with ultrasound guidance even more with positive risk factors. The generalities of prostate cancer are described. The general prostatic anatomy and echographic are reviewed. The echographic technique is analyzed in the exploration endorectal. The echographic findings suspects of prostate cancer are characterized. The different biopsy sampling techniques are described; and based on appropriate knowledge of prostatic echographic anatomy, could increase the effectiveness in the early detection of prostate cancer in patients with positive screening. The complications derived from the process are enumerated. The final recommendations are noted on the protocol described [es

  13. Adaptation of a 3D prostate cancer atlas for transrectal ultrasound guided target-specific biopsy

    International Nuclear Information System (INIS)

    Narayanan, R; Suri, J S; Werahera, P N; Barqawi, A; Crawford, E D; Shinohara, K; Simoneau, A R

    2008-01-01

    Due to lack of imaging modalities to identify prostate cancer in vivo, current TRUS guided prostate biopsies are taken randomly. Consequently, many important cancers are missed during initial biopsies. The purpose of this study was to determine the potential clinical utility of a high-speed registration algorithm for a 3D prostate cancer atlas. This 3D prostate cancer atlas provides voxel-level likelihood of cancer and optimized biopsy locations on a template space (Zhan et al 2007). The atlas was constructed from 158 expert annotated, 3D reconstructed radical prostatectomy specimens outlined for cancers (Shen et al 2004). For successful clinical implementation, the prostate atlas needs to be registered to each patient's TRUS image with high registration accuracy in a time-efficient manner. This is implemented in a two-step procedure, the segmentation of the prostate gland from a patient's TRUS image followed by the registration of the prostate atlas. We have developed a fast registration algorithm suitable for clinical applications of this prostate cancer atlas. The registration algorithm was implemented on a graphical processing unit (GPU) to meet the critical processing speed requirements for atlas guided biopsy. A color overlay of the atlas superposed on the TRUS image was presented to help pick statistically likely regions known to harbor cancer. We validated our fast registration algorithm using computer simulations of two optimized 7- and 12-core biopsy protocols to maximize the overall detection rate. Using a GPU, patient's TRUS image segmentation and atlas registration took less than 12 s. The prostate cancer atlas guided 7- and 12-core biopsy protocols had cancer detection rates of 84.81% and 89.87% respectively when validated on the same set of data. Whereas the sextant biopsy approach without the utility of 3D cancer atlas detected only 70.5% of the cancers using the same histology data. We estimate 10-20% increase in prostate cancer detection rates

  14. A MRI-CT prostate registration using sparse representation technique

    Science.gov (United States)

    Yang, Xiaofeng; Jani, Ashesh B.; Rossi, Peter J.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2016-03-01

    Purpose: To develop a new MRI-CT prostate registration using patch-based deformation prediction framework to improve MRI-guided prostate radiotherapy by incorporating multiparametric MRI into planning CT images. Methods: The main contribution is to estimate the deformation between prostate MRI and CT images in a patch-wise fashion by using the sparse representation technique. We assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. Specifically, there are two stages in our proposed framework, i.e., the training stage and the application stage. In the training stage, each prostate MR images are carefully registered to the corresponding CT images and all training MR and CT images are carefully registered to a selected CT template. Thus, we obtain the dense deformation field for each training MR and CT image. In the application stage, for registering a new subject MR image with the same subject CT image, we first select a small number of key points at the distinctive regions of this subject CT image. Then, for each key point in the subject CT image, we extract the image patch, centered at the underlying key point. Then, we adaptively construct the coupled dictionary for the underlying point where each atom in the dictionary consists of image patches and the respective deformations obtained from training pair-wise MRI-CT images. Next, the subject image patch can be sparsely represented by a linear combination of training image patches in the dictionary, where we apply the same sparse coefficients to the respective deformations in the dictionary to predict the deformation for the subject MR image patch. After we repeat the same procedure for each subject CT key point, we use B-splines to interpolate a dense deformation field, which is used as the initialization to allow the registration algorithm estimating the remaining small segment of deformations from MRI to CT image. Results: Our MRI-CT registration

  15. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K.

    2010-01-01

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  16. Relationship between apparent diffusion coefficients at 3.0-T MR imaging and Gleason grade in peripheral zone prostate cancer

    NARCIS (Netherlands)

    Hambrock, T.; Somford, D.M.; Huisman, H.J.; Oort, I.M. van; Witjes, J.A.; Hulsbergen-van de Kaa, C.A.; Scheenen, T.W.J.; Barentsz, J.O.

    2011-01-01

    PURPOSE: To retrospectively determine the relationship between apparent diffusion coefficients (ADCs) obtained with 3.0-T diffusion-weighted (DW) magnetic resonance (MR) imaging and Gleason grades in peripheral zone prostate cancer. MATERIALS AND METHODS: The requirement to obtain institutional

  17. Anatomical and metabolic assessment of prostate using a 3-Tesla MR scanner with a custom-made external transceive coil: healthy volunteer study.

    Science.gov (United States)

    Kaji, Yasushi; Kuroda, Kagayaki; Maeda, Takaki; Kitamura, Yuri; Fujiwara, Toshitaka; Matsuoka, Yuichiro; Tamura, Mitsuru; Takei, Naoyuki; Matsuda, Tsuyoshi; Sugimura, Kazuro

    2007-03-01

    To examine the possibility of using a 3 Tesla (T) magnetic resonance (MR) scanner with a custom-made external coil to obtain ductal details of the prostate, high-quality spectra, and metabolite mapping corresponding to prostate zonal anatomy in healthy volunteers. MRI and two-dimensional (2D) chemical shift imaging (CSI) were performed in 16 healthy volunteers using a 3T scanner with a custom-made external transmit-receive (transceive) coil. Visualization of the prostatic duct-like structure was analyzed on T2-weighted (T2W) images. The resolution of the metabolite peaks and the distribution of metabolites in CSI were also assessed. In the axial plane, 3-mm-thick images were better than 4-mm-thick images with the same voxel volume for assessing duct-like structures and prostatic urethra. Differentiation between inner and outer citrate (Cit) peaks was frequently observed (29 out of 30). The mean peak area ratio of choline (Cho) plus creatine (Cr) over Cit in the peripheral zone (PZ) was significantly lower than in the transition zone (TZ) (P = 0.014). 3T MR examinations of the prostate using an external coil allow information to be collected about the details of duct-like structures, the high-quality spectra of Cit, and the zone-specific distribution of metabolites.

  18. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, Baudouin; Maenhout, Metha; Lagendijk, JJW; van Vulpen, Marco; Hautvast, Gilion; Binnekamp, Dirk; Moerland, Rien

    2016-01-01

    PURPOSE: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image

  19. Rectal dose variation during the course of image-guided radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Chen Lili; Paskalev, Kamen; Xu Xiu; Zhu, Jennifer; Wang Lu; Price, Robert A.; Hu Wei; Feigenberg, Steven J.; Horwitz, Eric M.; Pollack, Alan; Charlie Ma, C.M.

    2010-01-01

    Background and purpose: To investigate the change in rectal dose during the treatment course for intensity-modulated radiotherapy (IMRT) of prostate cancer with image-guidance. Materials and methods: Twenty prostate cancer patients were recruited for this retrospective study. All patients have been treated with IMRT. For each patient, MR and CT images were fused for target and critical structure delineation. IMRT treatment planning was performed on the simulation CT images. Inter-fractional motion during the course of treatment was corrected using a CT-on-rails system. The rectum was outlined on both the original treatment plan and the subsequent daily CT images from the CT-on-rails by the same investigator. Dose distributions on these daily CT images were recalculated with the isocenter shifts relative to the simulation CT images using the leaf sequences/MUs based on the original treatment plan. The rectal doses from the subsequent daily CTs were compared with the original doses planned on the simulation CT using our clinical acceptance criteria. Results: Based on 20 patients with 139 daily CT sets, 28% of the subsequent treatment dose distributions did not meet our criterion of V 40 65 < 17%. The inter-fractional rectal volume variation is significant for some patients. Conclusions: Due to the large inter-fractional variation of the rectal volume, it is more favorable to plan prostate IMRT based on an empty rectum and deliver treatment to patients with an empty rectum. Over 70% of actual treatments showed better rectal doses than our clinical acceptance criteria. A significant fraction (27%) of the actual treatments would benefit from adaptive image-guided radiotherapy based on daily CT images.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  1. ESUR prostate MR guidelines 2012

    DEFF Research Database (Denmark)

    Barentsz, Jelle O; Richenberg, Jonathan; Clements, Richard

    2012-01-01

    The aim was to develop clinical guidelines for multi-parametric MRI of the prostate by a group of prostate MRI experts from the European Society of Urogenital Radiology (ESUR), based on literature evidence and consensus expert opinion. True evidence-based guidelines could not be formulated......, but a compromise, reflected by "minimal" and "optimal" requirements has been made. The scope of these ESUR guidelines is to promulgate high quality MRI in acquisition and evaluation with the correct indications for prostate cancer across the whole of Europe and eventually outside Europe. The guidelines...... provides guidelines for magnetic resonance imaging (MRI) in prostate cancer. Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described....

  2. Novel technique for MR elastography of the prostate using a modified standard endorectal coil as actuator.

    Science.gov (United States)

    Thörmer, Gregor; Reiss-Zimmermann, Martin; Otto, Josephin; Hoffmann, Karl-Titus; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald

    2013-06-01

    To present a novel method for MR elastography (MRE) of the prostate at 3 Tesla using a modified endorectal imaging coil. A commercial endorectal coil was modified to dynamically generate mechanical stress (contraction and dilation) in a prostate phantom with embedded phantom "lesions" (6 mm diameter) and in a porcine model. Resulting tissue displacements were measured with a motion-sensitive EPI sequence at actuation frequencies of 50-200 Hz. Maps of shear modulus G were calculated from the measured phase-difference shear-wave patterns. In the G maps of the phantom, "lesions" were easily discernible against the background. The average G values of regions of interest placed in the "lesion" (8.2 ± 1.9 kPa) were much higher than those in the background (3.6 ± 1.4 kPa) but systematically lower than values reported by the vendor (13.0 ± 1.0 and 6.7 ± 0.7 kPa, respectively). In the porcine model, shear waves could be generated and measured shear moduli were substantially different for muscle (7.1 ± 2.0 kPa), prostate (3.0 ± 1.4 kPa), and bulbourethral gland (5.6 ± 1.9 kPa). An endorectal MRE concept is technically feasible. The presented technique will allow for simultaneous MRE and MRI acquisitions using a commercial base device with minor, MR-conditional modifications. The diagnostic value needs to be determined in further trials. Copyright © 2012 Wiley Periodicals, Inc.

  3. MR-guided microwave ablation in hepatic tumours: initial results in clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Ruediger; Rempp, Hansjoerg; Kessler, David-Emanuel; Weiss, Jakob; Nikolaou, Konstantin; Clasen, Stephan [Eberhard-Karls-University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Pereira, Philippe L. [SLK-Kliniken Heilbronn GmbH, Department of Radiology, Minimally Invasive Therapies and Nuclear Medicine, Heilbronn (Germany)

    2017-04-15

    Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. (orig.)

  4. MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

    International Nuclear Information System (INIS)

    Merckel, Laura G.; Bartels, Lambertus W.; Köhler, Max O.; Bongard, H. J. G. Desirée van den; Deckers, Roel; Mali, Willem P. Th. M.; Binkert, Christoph A.; Moonen, Chrit T.; Gilhuijs, Kenneth G. A.; Bosch, Maurice A. A. J. van den

    2013-01-01

    Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

  5. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    OpenAIRE

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2008-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challengin...

  6. 18F Fluorocholine Dynamic Time-of-Flight PET/MR Imaging in Patients with Newly Diagnosed Intermediate- to High-Risk Prostate Cancer: Initial Clinical-Pathologic Comparisons.

    Science.gov (United States)

    Choi, Joon Young; Yang, Jaewon; Noworolski, Susan M; Behr, Spencer; Chang, Albert J; Simko, Jeffry P; Nguyen, Hao G; Carroll, Peter R; Kurhanewicz, John; Seo, Youngho

    2017-02-01

    Purpose To investigate the initial clinical value of fluorine 18 ( 18 F) fluorocholine (FCH) dynamic positron emission tomography (PET)/magnetic resonance (MR) imaging by comparing its parameters with clinical-pathologic findings in patients with newly diagnosed intermediate- to high-risk prostate cancer (PCa) who plan to undergo radical prostatectomy. Materials and Methods The institutional review board approved the study protocol, and informed written consent was obtained from all subjects for this HIPAA-compliant study. Twelve men (mean age ± standard deviation, 61.7 years ± 8.4; range, 46-74 years) with untreated intermediate- to high-risk PCa characterized according to Cancer of the Prostate Risk Assessment (CAPRA) underwent preoperative FCH dynamic PET/MR imaging followed by radical prostatectomy between April and November 2015. PET/MR imaging parameters including average and maximum K1 (delivery rate constant) and standardized uptake values (SUVs) and Prostate Imaging Reporting and Data System (PI-RADS) version 2 scores were measured and compared with clinical-pathologic characteristics. For statistical analysis, the Spearman rank correlation and Mann-Whitney U tests were performed. Results Of the PET parameters, maximum SUV of primary tumors showed significant correlations with several clinical-pathologic parameters including serum prostate-specific antigen level (ρ = 0.71, P = .01), pathologic stage (ρ = 0.59, P = .043), and postsurgical CAPRA score (ρ = 0.72, P = .008). The overall PI-RADS score showed significant correlations with pathologic tumor volume (ρ = 0.81, P PET and MR imaging showed improved sensitivity (88%) for prediction of pathologic extraprostatic extension compared with that with MR imaging (50%) and PET (75%) performed separately. Conclusion Maximum SUVs and PI-RADS scores from FCH PET/MR imaging show good correlation with clinical-pathologic characteristics, such as postsurgical CAPRA score, which are related to prognosis in

  7. MR-guided focused ultrasound. Current and future applications

    International Nuclear Information System (INIS)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M.; Napoli, A.; Matzko, M.

    2013-01-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [de

  8. [MR-guided focused ultrasound. Current and future applications].

    Science.gov (United States)

    Trumm, C G; Napoli, A; Peller, M; Clevert, D-A; Stahl, R; Reiser, M; Matzko, M

    2013-03-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier.

  9. Long-term follow-up after modern radical prostate cancer radiotherapy

    DEFF Research Database (Denmark)

    Sander, Lotte

    that clinical target volumes are up to 30% smaller on MRI delineation compared to computer tomography delineation. The overall aim of the thesis was to explore the use of MRI target planning and a Nicle-Titanium prostate stent as fiducial marker for both MR-CT co-registration and image guided radiotherapy....... radiotherapy is a well established treatment modality for prostate cancer. Accuracy and precision are key words with regard to optimal survival and minimal toxicity in modern radiotherapy and are fundamentals in modern radiotherapy. Modern imaging has improved the ability to define radiotherapy target volumes......A significant increase in the prostate cancer incidence has made prostate cancer a major health problem in recent years. Because of the often but unfortunately not always indolent nature of the disease, over-diagnosis and over-treatment are relevant clinical and ethic dilemmas. External beam...

  10. Technical note: Evaluation of the uncertainties in (choline+creatine)/citrate ratios measured by proton MR spectroscopic imaging in patients suspicious for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zbyn, S.; Krssak, M.; Memarsadeghi, M.; Gholami, B.; Haitel, A.; Weber, M.; Helbich, T.H.; Trattnig, S.; Moser, E.; Gruber, S.

    2014-07-15

    The presented evaluation of the relative uncertainty (δ'CCC) of the (choline + creatine)/citrate (CC/C) ratios can provide objective information about the quality and diagnostic value of prostate MR spectroscopic imaging data. This information can be combined with the numeric values of CC/C ratios and provides metabolic-quality maps enabling accurate cancer detection and user-independent data evaluation. In addition, the prostate areas suffering most from the low precision of CC/C ratios (e. g., prostate base) were identified.

  11. MR-guided Periarterial Ethanol Injection for Renal Sympathetic Denervation: A Feasibility Study in Pigs

    International Nuclear Information System (INIS)

    Streitparth, F.; Walter, A.; Stolzenburg, N.; Heckmann, L.; Breinl, J.; Rinnenthal, J. L.; Beck, A.; De Bucourt, M.; Schnorr, J.; Bernhardt, U.; Gebauer, B.; Hamm, B.; Günther, R. W.

    2013-01-01

    Purpose. To evaluate the feasibility and efficacy of image-guided periarterial ethanol injection as an alternative to transluminal radiofrequency ablation. Methods. Unilateral renal periarterial ethanol injection was performed under general anesthesia in 6 pigs with the contralateral kidney serving as control. All interventions were performed in an open 1.0 T MRI system under real-time multiplanar guidance. The injected volume was 5 ml (95 % ethanol labelled marked MR contrast medium) in 2 pigs and 10 ml in 4 pigs. Four weeks after treatment, the pigs underwent MRI including MRA and were killed. Norepinephrine (NE) concentration in the renal parenchyma served as a surrogate parameter to analyze the efficacy of sympathetic denervation. In addition, the renal artery and sympathetic nerves were examined histologically to identify evidence of vascular and neural injury. Results. In pigs treated with 10 ml ethanol, treatment resulted in neural degeneration. We found a significant reduction of NE concentration in the kidney parenchyma of 53 % (p < 0.02) compared with the untreated contralateral kidney. In pigs treated with 5 ml ethanol, no significant changes in histology or NE were observed. There was no evidence of renal arterial stenosis in MRI, macroscopy or histology in any pig. Conclusion. MR-guided periarterial ethanol injection was feasible and efficient for renal sympathetic denervation in a swine model. This technique may be a promising alternative to the catheter-based approach in the treatment of resistant arterial hypertension.

  12. MR-guided Periarterial Ethanol Injection for Renal Sympathetic Denervation: A Feasibility Study in Pigs

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, F., E-mail: florian.streitparth@charite.de; Walter, A.; Stolzenburg, N.; Heckmann, L.; Breinl, J. [Charite, Humboldt University, Department of Radiology (Germany); Rinnenthal, J. L. [Charite, Humboldt University, Department of Neuropathology (Germany); Beck, A.; De Bucourt, M.; Schnorr, J. [Charite, Humboldt University, Department of Radiology (Germany); Bernhardt, U. [InnoRa GmbH (Germany); Gebauer, B.; Hamm, B.; Guenther, R. W. [Charite, Humboldt University, Department of Radiology (Germany)

    2013-06-15

    Purpose. To evaluate the feasibility and efficacy of image-guided periarterial ethanol injection as an alternative to transluminal radiofrequency ablation. Methods. Unilateral renal periarterial ethanol injection was performed under general anesthesia in 6 pigs with the contralateral kidney serving as control. All interventions were performed in an open 1.0 T MRI system under real-time multiplanar guidance. The injected volume was 5 ml (95 % ethanol labelled marked MR contrast medium) in 2 pigs and 10 ml in 4 pigs. Four weeks after treatment, the pigs underwent MRI including MRA and were killed. Norepinephrine (NE) concentration in the renal parenchyma served as a surrogate parameter to analyze the efficacy of sympathetic denervation. In addition, the renal artery and sympathetic nerves were examined histologically to identify evidence of vascular and neural injury. Results. In pigs treated with 10 ml ethanol, treatment resulted in neural degeneration. We found a significant reduction of NE concentration in the kidney parenchyma of 53 % (p < 0.02) compared with the untreated contralateral kidney. In pigs treated with 5 ml ethanol, no significant changes in histology or NE were observed. There was no evidence of renal arterial stenosis in MRI, macroscopy or histology in any pig. Conclusion. MR-guided periarterial ethanol injection was feasible and efficient for renal sympathetic denervation in a swine model. This technique may be a promising alternative to the catheter-based approach in the treatment of resistant arterial hypertension.

  13. Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging

    NARCIS (Netherlands)

    Engelbrecht, Marc R.; Huisman, Henkjan J.; Laheij, Robert J. F.; Jager, Gerrit J.; van Leenders, Geert J. L. H.; Hulsbergen-van de Kaa, Christina A.; de La Rosette, Jean J. M. C. H.; Blickman, Johan G.; Barentsz, Jelle O.

    2003-01-01

    PURPOSE: To evaluate which parameters of dynamic magnetic resonance (MR) imaging and T2 relaxation rate would result in optimal discrimination of prostatic carcinoma from normal peripheral zone (PZ) and central gland (CG) tissues and to correlate these parameters with tumor stage, Gleason score,

  14. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  15. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael, E-mail: michael.meier@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Homsi, Rami, E-mail: rami.homsi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Kukuk, Guido, E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Wolter, Karsten, E-mail: karsten.wolter@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Decker, Georges, E-mail: georges.decker@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Fischer, Stefan, E-mail: stefan.fischer@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Marx, Christian, E-mail: christian.marx@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schmeel, Frederic Carsten, E-mail: carsten.schmeel@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Block, Wolfgang, E-mail: wolfgang.block@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Sprinkart, Alois Martin, E-mail: sprinkart@uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Hospital of the Barmherzige Brüder Trier, Nordallee 1, 54292 Trier (Germany)

    2016-12-15

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  16. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Homsi, Rami; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Schmeel, Frederic Carsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Willinek, Winfried

    2016-01-01

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  17. WE-EF-BRD-04: MR in the OR: The Growth and Applications of MRI for Interventional Radiology and Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fahrig, R. [Stanford University (United States)

    2015-06-15

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapy from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.

  18. The use of atlas registration and graph cuts for prostate segmentation in magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Korsager, Anne Sofie, E-mail: asko@hst.aau.dk; Østergaard, Lasse Riis [Department of Health Science and Technology, Aalborg University, Aalborg 9220 (Denmark); Fortunati, Valerio; Lijn, Fedde van der; Niessen, Wiro; Walsum, Theo van [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Rotterdam 3015 GE Rotterdam (Netherlands); Carl, Jesper [Department of Medical Physics, Oncology, Aalborg University Hospital, Aalborg 9220 (Denmark)

    2015-04-15

    Purpose: An automatic method for 3D prostate segmentation in magnetic resonance (MR) images is presented for planning image-guided radiotherapy treatment of prostate cancer. Methods: A spatial prior based on intersubject atlas registration is combined with organ-specific intensity information in a graph cut segmentation framework. The segmentation is tested on 67 axial T{sub 2}-weighted MR images in a leave-one-out cross validation experiment and compared with both manual reference segmentations and with multiatlas-based segmentations using majority voting atlas fusion. The impact of atlas selection is investigated in both the traditional atlas-based segmentation and the new graph cut method that combines atlas and intensity information in order to improve the segmentation accuracy. Best results were achieved using the method that combines intensity information, shape information, and atlas selection in the graph cut framework. Results: A mean Dice similarity coefficient (DSC) of 0.88 and a mean surface distance (MSD) of 1.45 mm with respect to the manual delineation were achieved. Conclusions: This approaches the interobserver DSC of 0.90 and interobserver MSD 0f 1.15 mm and is comparable to other studies performing prostate segmentation in MR.

  19. Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

    Science.gov (United States)

    Tsekos, Nikolaos V; Khanicheh, Azadeh; Christoforou, Eftychios; Mavroidis, Constantinos

    2007-01-01

    The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.

  20. Clinical outcome following a low-suspicion multiparametric prostate MRI or benign MRI-guided biopsy to detect prostate cancer

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    follow-up [132/156 (85%)] had decreasing levels of prostate-specific-antigen and could be monitored in primary care. CONCLUSION: A low-suspicion MRI in men with prior negative systematic biopsies has a high negative predictive value in ruling out longer term significant cancer. Therefore, immediate...... repeated biopsies are of limited clinical value and could be avoided even if prostate-specific-antigen levels are persistently elevated.......PURPOSE: To assess the future risk of detecting significant prostate cancer following either a low-suspicion MRI or suspicious MRI with benign MRI-guided biopsies in men with prior negative systematic biopsies. MATERIALS AND METHODS: 289 prospectively enrolled men underwent MRI followed by repeated...

  1. Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system

    International Nuclear Information System (INIS)

    Weihrauch, Mirko; Wust, Peter; Weiser, Martin; Nadobny, Jacek; Eisenhardt, Steffen; Budach, Volker; Gellermann, Johanna

    2007-01-01

    A combined numerical-experimental iterative procedure, based on the Gauss-Newton algorithm, has been developed for control of magnetic resonance (MR)-guided hyperthermia (HT) applications in a hybrid MR-HT system BSD 2000 3D-MRI. In this MR-HT system, composed of a 3-D HT applicator Sigma-Eye placed inside a tunnel-type MR tomograph Siemens MAGNETOM Symphony (1.5 T), the temperature rise due to the HT radiation can be measured on-line in three dimensions by use of the proton resonance frequency shift (PRFS) method. The basic idea of our iterative procedure is the improvement of the system's characterization by a step-by-step modification of the theoretical HT antenna profiles (electric fields radiated by single antennas). The adaptation of antenna profiles is efficient if the initial estimates are radiation fields calculated from a good a priori electromagnetic model. Throughout the iterative procedure, the calculated antenna fields (FDTD) are step-by-step modified by comparing the calculated and experimental data, the latter obtained using the PRFS method. The procedure has been experimentally tested on homogeneous and inhomogeneous phantoms. It is shown that only few comparison steps are necessary for obtaining a dramatic improvement of the general predictability and quality of the specific absorption rate (SAR) inside the MR-HT hybrid system

  2. Clinical results from first use of prostate stent as fiducial for radiotherapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Carl, Jesper; Nielsen, Jane (Dept. of Medical Physics, Dept. of Oncology, Aalborg Hospital, Aarhus Univ. Hospital, Aalborg (Denmark)), e-mail: jhc@rn.dk; Holmberg, Mats (Dept. of Oncology, Aalborg Hospital, Aarhus Univ. Hospital, Aalborg (Denmark)); Larsen, Erik Hoejkjaer; Fabrin, Knud (Dept. of Urology, Aalborg Hospital, Aarhus Univ. Hospital, Aalborg (Denmark)); Fisker, Rune V. (Dept. of Radiology, Aalborg Hospital, Aarhus Univ. Hospital, Aalborg (Denmark))

    2011-05-15

    Purpose. A clinical feasibility study using a removable prostate stent as fiducial for image-guided radiotherapy (IGRT) of localized prostate cancer (PC). Material and methods. The study included patients with local or locally advanced PC. The clinical target volume (CTV) was outlined on magnetic resonance (MR) images co-registered to planning computer tomography (CT) images. Daily online IGRT was delivered using the stent as fiducial. Risk of migration was estimated using multiple MR. Acute urinary toxicity was scored using the international prostate symptom score (IPSS). Late gastro-intestinal (GI) and genito-urinary (GU) toxicity was scored using the Radio Therapy Oncology Group (RTOG) score, biochemical failure (BF) was defined as an elevation of prostate specific antigen (PSA) above nadir plus 2 ng/ml after radiotherapy. Results. One hundred men were enrolled in the study. Ninety completed radiotherapy with the stent as fiducial. No migration of the stent was seen, but three cases of dislocation of the stent to the bladder were observed. Acute urinary toxicity based on IPSS was comparable to toxicity in patients who had gold markers (GM) as fiducials. Removal of the stent was associated with a high frequency of urinary retention. Late GI and GU toxicity and BF were comparable to those of other studies, but longer observation time is needed. Conclusions. This study reports the first clinical results of using a prostate stent as fiducial. No migration of the stent observed. Dislocation of the stent to the urinary bladder was observed in three cases, requiring removal of the stent and insertion of a new fiducial. Acute toxicity during radiotherapy evaluated from IPSS was comparable to toxicity in patients with GM. Removal of the stent was associated with a high frequency of post procedural urinary retention. Late toxicity and BF were comparable to those of other studies, though longer observation time is needed

  3. Clinical results from first use of prostate stent as fiducial for radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Larsen, Erik Hoejkjaer; Fabrin, Knud; Fisker, Rune V.

    2011-01-01

    Purpose. A clinical feasibility study using a removable prostate stent as fiducial for image-guided radiotherapy (IGRT) of localized prostate cancer (PC). Material and methods. The study included patients with local or locally advanced PC. The clinical target volume (CTV) was outlined on magnetic resonance (MR) images co-registered to planning computer tomography (CT) images. Daily online IGRT was delivered using the stent as fiducial. Risk of migration was estimated using multiple MR. Acute urinary toxicity was scored using the international prostate symptom score (IPSS). Late gastro-intestinal (GI) and genito-urinary (GU) toxicity was scored using the Radio Therapy Oncology Group (RTOG) score, biochemical failure (BF) was defined as an elevation of prostate specific antigen (PSA) above nadir plus 2 ng/ml after radiotherapy. Results. One hundred men were enrolled in the study. Ninety completed radiotherapy with the stent as fiducial. No migration of the stent was seen, but three cases of dislocation of the stent to the bladder were observed. Acute urinary toxicity based on IPSS was comparable to toxicity in patients who had gold markers (GM) as fiducials. Removal of the stent was associated with a high frequency of urinary retention. Late GI and GU toxicity and BF were comparable to those of other studies, but longer observation time is needed. Conclusions. This study reports the first clinical results of using a prostate stent as fiducial. No migration of the stent observed. Dislocation of the stent to the urinary bladder was observed in three cases, requiring removal of the stent and insertion of a new fiducial. Acute toxicity during radiotherapy evaluated from IPSS was comparable to toxicity in patients with GM. Removal of the stent was associated with a high frequency of post procedural urinary retention. Late toxicity and BF were comparable to those of other studies, though longer observation time is needed

  4. Clinical results from first use of prostate stent as fiducial for radiotherapy of prostate cancer.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Larsen, Erik Hoejkjaer; Fabrin, Knud; Fisker, Rune V

    2011-05-01

    A clinical feasibility study using a removable prostate stent as fiducial for image-guided radiotherapy (IGRT) of localized prostate cancer (PC). The study included patients with local or locally advanced PC. The clinical target volume (CTV) was outlined on magnetic resonance (MR) images co-registered to planning computer tomography (CT) images. Daily online IGRT was delivered using the stent as fiducial. Risk of migration was estimated using multiple MR. Acute urinary toxicity was scored using the international prostate symptom score (IPSS). Late gastro-intestinal (GI) and genito-urinary (GU) toxicity was scored using the Radio Therapy Oncology Group (RTOG) score, biochemical failure (BF) was defined as an elevation of prostate specific antigen (PSA) above nadir plus 2 ng/ml after radiotherapy. One hundred men were enrolled in the study. Ninety completed radiotherapy with the stent as fiducial. No migration of the stent was seen, but three cases of dislocation of the stent to the bladder were observed. Acute urinary toxicity based on IPSS was comparable to toxicity in patients who had gold markers (GM) as fiducials. Removal of the stent was associated with a high frequency of urinary retention. Late GI and GU toxicity and BF were comparable to those of other studies, but longer observation time is needed. This study reports the first clinical results of using a prostate stent as fiducial. No migration of the stent observed. Dislocation of the stent to the urinary bladder was observed in three cases, requiring removal of the stent and insertion of a new fiducial. Acute toxicity during radiotherapy evaluated from IPSS was comparable to toxicity in patients with GM. Removal of the stent was associated with a high frequency of post procedural urinary retention. Late toxicity and BF were comparable to those of other studies, though longer observation time is needed.

  5. Interventional MR: vascular applications.

    Science.gov (United States)

    Smits, H F; Bos, C; van der Weide, R; Bakker, C J

    1999-01-01

    Three strategies for visualisation of MR-dedicated guidewires and catheters have been proposed, namely active tracking, the technique of locally induced field inhomogeneity and passive susceptibility-based tracking. In this article the pros and cons of these techniques are discussed, including the development of MR-dedicated guidewires and catheters, scan techniques, post-processing tools, and display facilities for MR tracking. Finally, some of the results obtained with MR tracking are discussed.

  6. SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Elzibak, A; Fatemi-Ardekani, A; Soliman, A; Mashouf, S; Safigholi, H; Ravi, A; Morton, G; Song, WY [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Han, D [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/ TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify

  7. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  8. Molecular biomarkers to guide precision medicine in localized prostate cancer.

    Science.gov (United States)

    Smits, Minke; Mehra, Niven; Sedelaar, Michiel; Gerritsen, Winald; Schalken, Jack A

    2017-08-01

    Major advances through tumor profiling technologies, that include next-generation sequencing, epigenetic, proteomic and transcriptomic methods, have been made in primary prostate cancer, providing novel biomarkers that may guide precision medicine in the near future. Areas covered: The authors provided an overview of novel molecular biomarkers in tissue, blood and urine that may be used as clinical tools to assess prognosis, improve selection criteria for active surveillance programs, and detect disease relapse early in localized prostate cancer. Expert commentary: Active surveillance (AS) in localized prostate cancer is an accepted strategy in patients with very low-risk prostate cancer. Many more patients may benefit from watchful waiting, and include patients of higher clinical stage and grade, however selection criteria have to be optimized and early recognition of transformation from localized to lethal disease has to be improved by addition of molecular biomarkers. The role of non-invasive biomarkers is challenging the need for repeat biopsies, commonly performed at 1 and 4 years in men under AS programs.

  9. Multidisciplinary Intervention of Early, Lethal Metastatic Prostate Cancer: Report From the 2015 Coffey-Holden Prostate Cancer Academy Meeting

    Science.gov (United States)

    Miyahira, Andrea K.; Lang, Joshua M.; Den, Robert B.; Garraway, Isla P.; Lotan, Tamara L.; Ross, Ashley E.; Stoyanova, Tanya; Cho, Steve Y.; Simons, Jonathan W.; Pienta, Kenneth J.; Soule, Howard R.

    2018-01-01

    BACKGROUND The 2015 Coffey-Holden Prostate Cancer Academy Meeting, themed: “Multidisciplinary Intervention of Early, Lethal Metastatic Prostate Cancer,” was held in La Jolla, California from June 25 to 28, 2015. METHODS The Prostate Cancer Foundation (PCF) sponsors an annual, invitation-only, action-tank-structured meeting on a critical topic concerning lethal prostate cancer. The 2015 meeting was attended by 71 basic, translational, and clinical investigators who discussed the current state of the field, major unmet needs, and ideas for addressing earlier diagnosis and treatment of men with lethal prostate cancer for the purpose of extending lives and making progress toward a cure. RESULTS The questions addressed at the meeting included: cellular and molecular mechanisms of tumorigenesis, evaluating, and targeting the microenvironment in the primary tumor, advancing biomarkers for clinical integration, new molecular imaging technologies, clinical trials, and clinical trial design in localized high-risk and oligometastatic settings, targeting the primary tumor in advanced disease, and instituting multi-modal care of high risk and oligometastatic patients. DISCUSSION This article highlights the current status, greatest unmet needs, and anticipated field changes that were discussed at the meeting toward the goal of optimizing earlier interventions to potentiate cures in high-risk and oligometastatic prostate cancer patients. PMID:26477609

  10. Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performance.

    NARCIS (Netherlands)

    Heijmink, S.W.T.P.J.; Futterer, J.J.; Hambrock, T.; Takahashi, S.; Scheenen, T.W.J.; Huisman, H.J.; Hulsbergen-van de Kaa, C.A.; Knipscheer, B.C.; Kiemeney, L.A.L.M.; Witjes, J.A.; Barentsz, J.O.

    2007-01-01

    PURPOSE: To prospectively compare image quality and accuracy of prostate cancer localization and staging with body-array coil (BAC) versus endorectal coil (ERC) T2-weighted magnetic resonance (MR) imaging at 3 T, with histopathologic findings as the reference standard. MATERIALS AND METHODS: After

  11. SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

    Energy Technology Data Exchange (ETDEWEB)

    He, R.; Giri, Shankar [University of Mississippi Med. Center, Jackson, MS (United States); VA Medical Center at Jackson, Mississippi (United States); Kumar, P. [VA Medical Center at Jackson, Mississippi (United States); Hu, Y.; Suggs, J.; Yang, C. [University of Mississippi Med. Center, Jackson, MS (United States)

    2014-06-01

    Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.

  12. SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

    International Nuclear Information System (INIS)

    He, R.; Giri, Shankar; Kumar, P.; Hu, Y.; Suggs, J.; Yang, C.

    2014-01-01

    Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation

  13. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  14. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  15. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder; Ultraschallgesteuerte intraartikulaere Kontrastmittelapplikation fuer die MR-Arthrografie der Schulter

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K. [Inst. fuer Roentgendiagnostik, Klinikum rechts der Isar der Technischen Univ. Muenchen (Germany)

    2010-03-15

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  16. Behaviour change techniques in physical activity interventions for men with prostate cancer: A systematic review.

    Science.gov (United States)

    Hallward, Laura; Patel, Nisha; Duncan, Lindsay R

    2018-02-01

    Physical activity interventions can improve prostate cancer survivors' health. Determining the behaviour change techniques used in physical activity interventions can help elucidate the mechanisms by which an intervention successfully changes behaviour. The purpose of this systematic review was to identify and evaluate behaviour change techniques in physical activity interventions for prostate cancer survivors. A total of 7 databases were searched and 15 studies were retained. The studies included a mean 6.87 behaviour change techniques (range = 3-10), and similar behaviour change techniques were implemented in all studies. Consideration of how behaviour change techniques are implemented may help identify how behaviour change techniques enhance physical activity interventions for prostate cancer survivors.

  17. Polygenic hazard score to guide screening for aggressive prostate cancer

    DEFF Research Database (Denmark)

    Seibert, Tyler M; Fan, Chun Chieh; Wang, Yunpeng

    2018-01-01

    . These polymorphisms were incorporated into a survival analysis to estimate their effects on age at diagnosis of aggressive PCa (that is, not eligible for surveillance according to National Comprehensive Cancer Network guidelines; any of Gleason score ≥7, stage T3-T4, PSA (prostate specific antigen) concentration ≥10......OBJECTIVES: To develop and validate a genetic tool to predict age of onset of aggressive prostate cancer (PCa) and to guide decisions of who to screen and at what age. DESIGN: Analysis of genotype, PCa status, and age to select single nucleotide polymorphisms (SNPs) associated with diagnosis...

  18. Preparation and management of complications in prostate biopsies

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-12-01

    Full Text Available Transrectal ultrasonography-guided biopsy plays a key role in prostate sampling for cancer detection. Among interventional procedures, it is one of the most frequent procedures performed by radiologists. Despite the safety and low morbidity of such procedure, possible complications should be promptly assessed and treated. The standardization of protocols and of preprocedural preparation is aimed at minimizing complications as well as expediting their management. The authors have made a literature review describing the possible complications related to transrectal ultrasonography-guided prostate biopsy, and discuss their management and guidance to reduce the incidence of such complications.

  19. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    Science.gov (United States)

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  20. Prostatic Artery Embolization After Failed Urological Interventions for Benign Prostatic Obstruction: A Case Series of Three Patients

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, Shivank S., E-mail: sbhatia1@med.miami.edu; Dalal, Ravi, E-mail: rdalal@med.miami.edu [University of Miami – Miller School of Medicine, Department of Radiology (United States); Gomez, Christopher, E-mail: Cgomez7@med.miami.edu [University of Miami – Miller School of Medicine, Department of Urology (United States); Narayanan, Govindarajan, E-mail: gnarayanan@med.miami.edu [University of Miami – Miller School of Medicine, Department of Radiology (United States)

    2016-08-15

    Benign prostate obstruction with associated lower urinary tract symptoms is a common diagnosis with multiple minimally invasive treatment options available. Herein, the authors describe three patients who failed prior different urological interventions who underwent prostate artery embolization with a subsequent improvement in symptoms. The positive response suggests that embolization may be an effective treatment alternative in this subset of patients.

  1. Magnetic resonance (MR) imaging of prostatic tumours, a comparison with X-ray CT and transrectal sonography (TRS)

    Energy Technology Data Exchange (ETDEWEB)

    Bockisch, A.; Biersack, H.J.; Huenermann, B.; Schmitz, H.G.; Knopp, R.; Winkler, C.; Jaeger, N.; Vahlensieck, W.; Christ, F.

    1988-02-01

    A total of 7 healthy volunteers and 31 patients have been examined clinically, by MRI, TRS, and biopsy. In those patients with established carcinoma, a CT examination was also performed. For the MRI study, a superconducting MR 2000 imager (Picker International) operated at 0.15 T was used with multiplanar SE and IR sequnces. SE sequences with long echo times detected prostatitis, adenoma and carcinoma of the prostate with a high degree of sensitivity. However, at present, differentiation between adenoma, prostatis and carcinoma is not possible with sufficient accuracy. In these studies we were unable to establish a correlation between the signal pattern and staging and/or grading of the carcinoma. Reliable diagnosis of a prostate carcinoma still requires a biopsy. Because of the high soft tissue contrast and the possibility of selecting any orientation for the plane under investigation, however, MRI represents an improvement in the preoperative diagnosis of local spread.

  2. The effect of androgen deprivation on the early changes in prostate volume following transperineal ultrasound guided interstitial therapy for localized carcinoma of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Richard; Broderick, Gregory A; Arger, Peter; Malkowicz, S Bruce; Epperson, Robert D; Arjomandy, Bijan; Kassaee, Alireza

    1999-07-15

    Purpose: To determine the change in volume of the prostate as a result of neoadjuvant androgen deprivation prior to prostate implant and in the early postimplant period following transperineal ultrasound guided palladium-103 brachytherapy for early-stage prostate cancer. Methods and Materials: Sixty-nine men received 3 to 6 months of androgen deprivation therapy followed by treatment planning ultrasound followed 4 to 8 weeks later by palladium-103 implant of the prostate. All patients had clinical and radiographic stage T1c-T2b adenocarcinoma of the prostate. A second ultrasound study was carried out 11 to 13 days following the implant to determine the change in volume of the prostate as a result of the implant. The prehormonal and preimplant volumes were compared to the postimplant volume to determine the effect of hormones and brachytherapy on prostate volume. Results: The median decrease in prostate volume as a result of androgen deprivation was 33% among the 54 patients with prostate volume determinations prior to hormonal therapy. The reduction in volume was greatest in the quartile of men with the largest initial gland volume (59%) and least in the quartile of men with smallest glands (10%). The median reduction in prostate volume between the treatment planning ultrasound and the follow-up study after implant was 3%, but 23 (33%) patients had an increase in prostate volume, including 16 (23%) who had an increase in volume >20%; 11 of these patients (16%) had an increase in volume >30%. The time course of development and resolution of this edema is not known. The severity of the edema was not related to initial or preimplant prostate volume or duration of hormonal therapy. Conclusions: Prostate edema may significantly affect the dose delivered to the prostate following transperineal ultrasound guided brachytherapy. The effect on the actual delivered dose will be greater when shorter lived isotopes are used. It remains to be observed whether this edema will

  3. Morphological MRI and 3D proton spectroscopy using endorectal coil in the diagnostics of prostate cancer - preliminary experience

    International Nuclear Information System (INIS)

    Chrzan, R.; Urbanik, A.; Dobrowolski, Z.; Lipczynski, M.

    2006-01-01

    Morphological MR imaging using endorectal coil has high sensitivity but insufficient specificity in the detection of prostatic cancer. Higher specificity may be obtained by combining morphological MR with data on local metabolic disturbances in MR spectroscopy. The aim of our study was to assess the diagnostic accuracy of combined morphological MR and 3D proton spectroscopy using endorectal coil in prostate cancer detection. Morphological MR and 3D proton MR spectroscopy were performed in 20 patients with suspicion of prostate cancer on the basis of DRE, TRUS and/or PSA levels, finally verified in biopsy after MR. The examinations were performed with a 1.5 T GE Signa Excite scanner using an endorectal coil. We used axial, coronal and sagittal T2 FSE, axial T1 SE and 3D PROSE (PROstate Spectroscopy and imaging Examination) sequences. The diagnostic accuracy of combined morphological and spectroscopy assessment was compared to the accuracy of morphological MR alone. The specificity, PPV, and NPV of MR imaging using endorectal coil in the detection of prostatic cancer were higher in combined morphological and spectroscopic assessment compared to morphological assessment alone. 3D MR spectroscopy, in comparison to morphological MR imaging, provides additional data concerning metabolic disturbances in prostate cancer foci. The use of combined morphological MR and MR spectroscopy can improve the specificity of prostate cancer detection. (author)

  4. An online psychological intervention can improve the sexual satisfaction of men following treatment for localized prostate cancer: outcomes of a Randomised Controlled Trial evaluating My Road Ahead.

    Science.gov (United States)

    Wootten, Addie C; Meyer, Denny; Abbott, Jo-Anne M; Chisholm, Katherine; Austin, David W; Klein, Britt; McCabe, Marita; Murphy, Declan G; Costello, Anthony J

    2017-07-01

    Prostate cancer treatment often results in significant psycho-sexual challenges for men following treatment; however, many men report difficulty in accessing appropriate care. A randomized controlled trial was undertaken to assess the efficacy of a 10-week self-guided online psychological intervention called My Road Ahead (MRA) for men with localized prostate cancer in improving sexual satisfaction. Participants were randomized to 1 of 3 conditions MRA alone or MRA plus online forum, or forum access alone. Pre, post, and follow-up assessments of overall sexual satisfaction were conducted. Mixed models and structural equation modeling were used to analyze the data. One hundred forty-two men (mean age 61 y; SD = 7) participated. The majority of participants had undergone radical prostatectomy (88%) and all men had received treatment for localized prostate cancer. Significant differences were obtained for the 3 groups (P = .026) and a significant improvement in total sexual satisfaction was observed only for participants who were allocated to MRA + forum with a large effect size (P = .004, partial η 2  = 0.256). Structural equation modeling indicated that increases in sexual function, masculine self-esteem, and sexual confidence contributed significantly to overall sexual satisfaction for the MRA + forum plus forum condition. This study is the first, to our knowledge, that has evaluated a self-guided online psychological intervention tailored to the specific needs of men with prostate cancer. The findings indicate the potential for MRA to deliver support that men may not otherwise receive and also highlight the importance of psychological intervention to facilitate improved sexual outcomes. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration

    International Nuclear Information System (INIS)

    Parker, C.C.; Damyanovich, A.; Haycocks, T.; Haider, M.; Bayley, A.; Catton, C.N.

    2003-01-01

    Purpose: To assess the feasibility, and potential implications, of using intra-prostatic fiducial markers, rather than bony landmarks, for the co-registration of computed tomography (CT) and magnetic resonance (MR) images in the radiation treatment planning of localized prostate cancer. Methods: All men treated with conformal therapy for localized prostate cancer underwent routine pre-treatment insertion of prostatic fiducial markers to assist with gross target volume (GTV) delineation and to identify prostate positioning during therapy. Six of these men were selected for investigation. Phantom MRI measurements were obtained to quantify image distortion, to determine the most suitable gold alloy marker composition, and to identify the spin-echo sequences that optimized both marker identification and the contrast between the prostate and the surrounding tissues. The GTV for each patient was contoured independently by three radiation oncologists on axial planning CT slices, and on axial MRI slices fused to the CT slices by matching the implanted fiducial markers. From each set of contours the scan common volume (SCV), and the scan encompassing volume (SEV), were obtained. The ratio SEV/SCV for a given scan is a measure of inter-observer variation in contouring. For each of the 18 patient-observer combinations the observer common volume (OCV) and the observer encompassing volume (OEV) was obtained. The ratio OEV/OCV for a given patient-observer combination is a measure of the inter-modality variation in contouring. The distance from the treatment planning isocenter to the prostate contours was measured and the discrepancy between the CT- and the MR-defined contour recorded. The discrepancies between the CT- and MR-defined contours of the posterior prostate were recorded in the sagittal plane at 1-cm intervals above and below the isocenter. Results: Phantom measurements demonstrated trivial image distortion within the required field of view, and an 18K Au/Cu alloy to

  6. Interventional MR-Mammography: manipulator-assisted large core biopsy and interstitial laser therapy of tumors of the female breast; Interventionelle MR-Mammographie: Manipulatorgestuetzte Biopsie und interstitielle Lasertherapie von Tumoren der weiblichen Brust

    Energy Technology Data Exchange (ETDEWEB)

    Pfleiderer, S.O.R.; Reichenbach, J.R.; Wurdinger, S.; Marx, C.; Freesmeyer, M.G.; Kaiser, W.A. [Inst. fuer Diagnostische und Interventionelle Radiologie, Friedrich-Schiller-Univ. Jena (Germany); Vagner, J.; Fischer, H. [Inst. fuer Medizintechnik und Biophysik, Forschungszentrum Karlsruhe (Germany); Schneider, A. [Klinik fuer Frauenheilkunde, Friedrich-Schiller-Univ. Jena (Germany)

    2003-07-01

    The present study investigated the clinical application of magnetic resonance (MR)-guided breast interventions, such as manipulator-assisted large core breast biopsy (LCBB) inside a 1.5 T whole-body magnet and MR-guided interstitial laser therapy (ILT). Sixteen patients underwent LCBB and 1 additional patient underwent 4 sessions of ILT of a recurrent undifferentiated lymph node metastasis in the axilla using a Nd-YAG laser (1064 nm). Temperature changes of the tumor tissue during ILT were monitored using phase images of a gradient echo sequence (GRE) (TR/TE/FA = 25/12/30). In 5 patients the biopsy findings were histopathologically confirmed after open surgery. In 3 patients, the biopsy missed one tubular and one ductal carcinoma; one invasive carcinoma was underestimated. Eight patients with benign findings are still in the follow-up period. The heating zone during ILT was well delineated on subtracted phase images. No severe adverse events were observed with LCBB or ILT. MR-guided breast biopsies are feasible with the manipulator system inside a whole-body 1.5 Tesla MR scanner. GRE information is suitable for therapy monitoring during ILT within the tumor. Further studies are necessary to evaluate the accuracy of the manipulator system and the efficacy of ILT in the treatment of breast lesions. (orig.) [German] Die klinische Anwendung MR-gestuetzter Interventionen an der Mamma wie die roboterassistierte Brustbiopsie innerhalb eines Ganzkoerpertomographen oder die kernspintomographisch kontrollierte interstitielle Lasertherapie (ILT) wurden untersucht. 16 Patientinnen unterzogen sich einer Brustbiopsie. Eine weitere Patientin wurde in insgesamt 4 Sitzungen mit einem Nd-YAG-Laser (1064 nm) an einem undifferenzierten axillaeren Lymphknotenrezidiv eines Mammakarzinoms behandelt. Temperaturaenderungen im Tumor waehrend der ILT wurden mit Hilfe von Phasenbildern einer Gradientenechosequenz (GRE) (TR/TE/FA = 25/12/30) visualisiert. Bei 5 Patientinnen wurde der

  7. MR-guided biopsies of lesions in the retroperitoneal space: technique and results

    International Nuclear Information System (INIS)

    Zangos, S.; Eichler, K.; Wetter, A.; Lehnert, T.; Hammerstingl, R.; Diebold, T.; Reichel, P.; Herzog, C.; Mack, M.G.; Vogl, T.J.; Hansmann, M.-L.

    2006-01-01

    The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90 ) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90 ) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies. (orig.)

  8. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  9. Sedation as an alternative method to lessen patient discomfort due to transrectal ultrasonography-guided prostate biopsy

    International Nuclear Information System (INIS)

    Turgut, A.T.; Ergun, E.; Kosar, U.; Kosar, P.; Ozcan, A.

    2006-01-01

    Background: Despite being highly efficient for the relief of patient discomfort due to transrectal ultrasound (TRUS) guided prostate biopsy, periprostatic anesthesia is occasionally reported to be of limited use. We aimed to evaluate the efficacy of conscious sedation, an accepted method for lessening patient discomfort due to interventional radiological procedures and compare it with periprostatic anesthesia. Methods: 93 candidates for biopsy were randomised to three groups: group 1 (n = 31) received intravenous midazolam, group 2 (n = 31) received periprostatic lidocaine injection, whereas group 3 (n = 31) received no anesthetic before the procedure. After the biopsy patients were asked to express discomfort by visual anologue scale (VAS). Results: The mean scores for groups 1 and 2 were significantly lower than that of group 3 (1.4 ± 1.1 and 2.0 ± 1.5 versus 4.7 ± 1.6, respectively; p < 0.05 for both). For patients with VAS scores exceeding 4 (moderate to severe discomfort), a significant difference was calculated between groups 1 and 2 (3% versus 29%, p < 0.05) and between each and group 3 (3% and 29% versus 80%, respectively; p < 0.05 for each). Conclusions: Sedation is an alternative for increasing patient comfort during TRUS-guided prostate biopsy, especially in clinical situations like patient anxiety, young age, repeat biopsies or inflammatory anal diseases

  10. Multiparametric MRI in the detection of clinically significant prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Futterer, Jurgen J. [Dept. of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen (Netherlands)

    2017-08-01

    Prostate cancer is the most common cancer among men aged 50 years and older in developed countries and the third leading cause of cancer-related death in men. Multiparametric prostate MR imaging is currently the most accurate imaging modality to detect, localize, and stage prostate cancer. The role of multi-parametric MR imaging in the detection of clinically significant prostate cancer are discussed. In addition, insights are provided in imaging techniques, protocol, and interpretation.

  11. The value of MRI three-dimensional reconstruction in diagnosis and therapy of prostate cancer

    International Nuclear Information System (INIS)

    Li Feiyu; Wang Xiaoying; Xu Yufeng; Xiao Jiangxi; Jiang Xuexiang

    2006-01-01

    Objective: To evaluate three-dimensional reconstruction of MRI images in diagnosis and therapy of prostate cancer. Methods: Twenty-eight patients with proven prostate cancers were recruited in this study. Seventeen of them were diagnosed as having prostate cancer according to the ultrasound guided systemic biopsy. Their MR examinations showed fourteen lesions in the peripheral zone and three in the central gland of the prostate. The other eleven patients underwent MR examination after a period of treatment, including endocrinetherapy and brachytherapy. Using endorectal coil, a series of T 2 -weighted images were acquired on the axial plane. These source images were processed by 3D-Doctor software to reconstruct into three-dimensional images. Results: In the fourteen patients with peripheral zone cancer, reconstruction images could display the 3D regions of cancer and the involvement of capsular. The outspread of central gland and the compression of peripheral zone in patients with central gland cancer could be revealed in the same way. The volumetric changes of the lesion and the prostate after endocrinetherapy could also be perceived through these 3 D images. Similarly, radioactive seeds were revealed in a spatial manner that could be easily evaluated. Conclusion: Three-dimensional reconstruction images were obtained in all patients. They were able to provide stereotyped information about the lesions and their surrounding tissues. MRI three-dimensional reconstruction can be an adjunctive tool in the evaluation of prostate lesions. (authors)

  12. ESUR prostate MR guidelines 2012

    Energy Technology Data Exchange (ETDEWEB)

    Barentsz, Jelle O.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Center, Department of Radiology, Nijmegen (Netherlands); Richenberg, Jonathan [Brighton and Sussex University Hospital Trust, Brighton (United Kingdom); Clements, Richard [Royal Gwent Hospital, Department of Clinical Radiology, Newport, South Wales (United Kingdom); Choyke, Peter [National Cancer Institute, Molecular Imaging Program, Bethesda, MD (United States); Verma, Sadhna [University Of Cincinnati Medical Center, Cincinnati, OH (United States); Villeirs, Geert [Ghent University Hospital, Division of Genitourinary Radiology, Ghent (Belgium); Rouviere, Olivier [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Imaging, Lyon (France); Universite de Lyon, Lyon (France); Universite Lyon 1, Faculte de Medecine Lyon Est, Lyon (France); Logager, Vibeke [Copenhagen University, Hospital Herlev, Herlev (Denmark)

    2012-04-15

    The aim was to develop clinical guidelines for multi-parametric MRI of the prostate by a group of prostate MRI experts from the European Society of Urogenital Radiology (ESUR), based on literature evidence and consensus expert opinion. True evidence-based guidelines could not be formulated, but a compromise, reflected by ''minimal'' and ''optimal'' requirements has been made. The scope of these ESUR guidelines is to promulgate high quality MRI in acquisition and evaluation with the correct indications for prostate cancer across the whole of Europe and eventually outside Europe. The guidelines for the optimal technique and three protocols for ''detection'', ''staging'' and ''node and bone'' are presented. The use of endorectal coil vs. pelvic phased array coil and 1.5 vs. 3 T is discussed. Clinical indications and a PI-RADS classification for structured reporting are presented. (orig.)

  13. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    Science.gov (United States)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  14. Diffusion-weighted magnetic resonance imaging in the prostate transition zone: histopathological validation using magnetic resonance-guided biopsy specimens

    NARCIS (Netherlands)

    Hoeks, C.M.A.; Vos, E.K.; Bomers, J.G.R.; Barentsz, J.O.; Kaa, C.A. van de; Scheenen, T.W.J.

    2013-01-01

    OBJECTIVES: The objective of this study was to evaluate the apparent diffusion coefficient (ADC) of diffusion-weighted magnetic resonance (MR) imaging for the differentiation of transition zone cancer from non-cancerous transition zone with and without prostatitis and for the differentiation of

  15. MR-guided percutaneous nephrostomy of the contrast-enhanced, nondilated upper urinary tract: initial experimental results; MR-tomographisch gesteuerte perkutane Nephrostomie des kontrastangehobenen, nicht dilatierten oberen Harntraktes: Erste experimentelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Buecker, A.; Neuerburg, J.M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik; Hunter, D.W. [Minnesota Univ. (United States). Dept. of Radiology

    1998-06-01

    Purpose: To evaluate technique and practicability of MR-guided percutaneous nephrostomy (MRPCN) in an animal model. Methods: In three domestic pigs, a unilateral percutaneous nephrostomy tube was placed into the nondilated collecting system using exclusively MR-guidance with a standard 1.5 T scanner. The urinary tract was visualized by intravenous injection of Gd-DTPA and low-dose furosemide. The entire interventional procedure was controlled using a T{sub 1}-weighted `dual stack` 2D TFE sequence in two orthogonal planes. Results: In all three animals, the puncture needle was safely directed into the nondilated target calyx. Even slight deviations of the needle from the optimal path were readily detected on both MR image planes which enabled immediate correction. This technique successfully achieved a `first attempt` puncture of the targeted calyx in each animal. Over a nitinol guidewire a 5 F catheter was placed into the renal pelvis. Its dysprosium labelled tip was acurately delineated on contrast-enhanced MR images. Conclusions: Percutaneous nephrostomy under MR guidance is a very feasible technique for puncturing the nondilated pelvicalyceal system. This procedure offers some advantages over the current standard modalities. (orig.) [Deutsch] Ziel: Ueberpruefung von Technik und Durchfuehrbarkeit einer MR-tomographisch gesteuerten perkutanen Nephrostomie (MR-PNS) im Tierexperiment. Methoden: Bei drei Hausschweinen wurde eine einseitige perkutane Nephrostomie des nicht dilatierten Hohlraumsystems ausschliesslich unter MR-tomographischer Kontrolle mit einem geschlossenen 1,5-T-System durchgefuehrt. Die Kontrastierung des oberen Harntraktes erfolgte durch eine intravenoese Injektion von Gd-DTPA und niedrigdosiertem Furosemid. Die einzelnen Interventionsschritte wurden mit einem T{sub 1}-gewichteten `Doppel-Schichtstapel` 2D-TFE Sequenz in zwei orthogonalen Schichtebenen kontrolliert. Ergebnisse: Bei allen drei Versuchstieren liess sich die Punktionsnadel unter MR

  16. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  17. Effect of transurethral microwave thermotherapy. An evaluation with MR imaging

    International Nuclear Information System (INIS)

    Nordenstam, G.; Aspelin, P.; Isberg, B.; Svensson, L.; Hallin, A.; Berlin, T.

    1996-01-01

    Purpose: To detect morphological changes in the prostate, as depicted with MR imaging, in order to clarify the effects of transurethral microwave thermotherapy (TUMT). Material and Methods: Twenty patients with prostatism and a prostatic volume of 30-71 cm 3 underwent MR examination before, the day after, and 6 months after treatment. TUMT was carried out with a Prostatron. A method to detect oedematous changes on heavily T2-weighted MR images was developed and used as an indicator of morphological changes. Results: The study showed some correlation (r=0.59) between the energy given at TUMT and an increased T2 signal. All patients with increased T2 signal except one were found among those who received the highest amount of energy to the prostate. Of 8 patients, 6 showed a symptomatic response to the treatment and 2 did not. There was a weak statistical correlation (r=0.41) between treatment response and increased T2 signal. Conclusion: The study does not support the view that TUMT leads to significant necrosis in the prostate with loss of tissue and retraction. We theorize that the response to TUMT may be caused by a denervation of the prostate. (orig.)

  18. [Active surveillance for prostate cancer: usefulness of endorectal MR at 1.5 Tesla with pelvic phased array coil in detecting significant tumors].

    Science.gov (United States)

    Luyckx, F; Hallouin, P; Barré, C; Aillet, G; Chauveau, P; Hétet, J-F; Bouchot, O; Rigaud, J

    2011-02-01

    To describe and assess MRI signs of significant tumor in a series of patients who all underwent radical prostatectomy and also fulfilled criteria to choose active surveillance according to French "SurAcaP" protocol. The clinical reports of 681 consecutive patients operated on for prostate cancer between 2002 and 2007 were reviewed retrospectively. All patients had endorectal MR (1.5 Tesla) with pelvic phased array coil. (1.5 T erMR PPA). Sixty-one patients (8.9%) fulfilled "SurAcaP" protocol criteria. Preoperative data (MR+core biopsy) were assessed by comparison to whole-mount step section pathology. 85.3% of the 61 patients entering SurAcaP protocol had significant tumor at pathology. (Non Organ Confined Disease (Non OCD)=8.2%, Gleason sum score>6=39.2%). A new exclusion criterion has been assessed: T3MRI±NPS>1 as a predictor tool of significant tumor. ("T3MRI±NPS>1"=Non OCD at MR±number of positive sextants involved in tumor at MR and/or Core Biopsy > to 1). Sensitivity, specificity, PPV, NPV of the criterion "T3MRI±NPS>1" in predicting significant tumor were, respectively: 77%, 33%, 86%, 20%. Adding this criterion to other criteria of the "SurAcaP" protocol could allow the exclusion of all Non OCD, and a decrease in Gleason sum Score>6 rates (20%). Endorectal MR at 1.5 Tesla with pelvic-phased array coil should be considered when selecting patients for active surveillance in the management of prostate cancer. A criterion based upon MR and core biopsy findings, called "T3MR±NSP>1" may represent an exclusion citeria due to its ability to predict significant tumor. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  19. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  20. MRI for troubleshooting detection of prostate cancer; MRT zur Problemloesung beim Nachweis des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Beyersdorff, D.; Hamm, B. [Universitaetsmedizin Berlin, Charite Mitte (Germany)

    2005-06-01

    Prostate cancer is the most common malignancy in males. Men aged 50 and older are recommended to undergo an annual digital rectal examination (DRE) and determination of prostate-specific antigen (PSA) in serum for early detection. However, prostate biopsies guided by transrectal ultrasound (TRUS) come up negative for cancer in many patients despite having PSA levels above 4 ng/ml. T2-weighted Magnetic Resonance Imaging (MRI) is able to represent the prostate including the surrounding anatomy and depict suspicious areas of low intensity within a high-intensity peripheral zone. MRI has a higher sensitivity for detecting prostate carcinomas than DRE and TRUS in patients having an elevated PSA value and a negative core biopsy. However, its specificity is poor since other abnormalities such as prostatic intraepithelial neoplasia (PIN), prostatitis, scars, or haemmorrhage have a similar MRI appearance. The use of additional techniques such as MR spectroscopy and contrast-enhanced dynamic MRI improves sensitivity, but in particular it improves the specificity of tumor detection. Newly developed biopsy devices enable the performance of targeted biopsies in areas that appear suspicious in the MRI. (orig.)

  1. Interventional magnetic resonance imaging - non-invasive imaging for interventions; Interventionelle Magnetresonanztomographie - nichtinvasive Bildgebung fuer Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A.; Adam, G.; Neuerburg, J.M.; Glowinski, A.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Medizinische Fakultaet

    2000-02-01

    As a prerequisite for MR-guidance of interventional procedures, instruments have to be well depicted in the MR image without obscuring or distorting the underlying anatomy. For non-vascular interventions the imaging speed has to be in the range of seconds while control of vascular interventions requires real time imaging speed. The imaging contrast has to be maintained as well as a high spatial resolution. Furthermore, sufficient patient access has to be provided by the MR scanner. Neither an ideal magnet nor the optimal single sequence are available to fulfill the above-mentioned criteria. The type of sequence - gradient echo versus spin echo - together with changing of the echo time and phase encording direction will ensure an appropriate size of the artifact and thereby of the appearance of the instrument in the MR image. The feasibility of non-vascular MR-guided interventions has been proved at field strengths ranging from 0.064 T to 1.5 T. Bone biopsies, soft tissue biopsies, drainages, and control of interstitial thermo- and cryotherapy have been reported. For vascular interventions, different real time MR strategies are currently under investigation. The development of dedicated catheters and guide wires has enabled MR-guided dilatations, stenting, placement of vena cava filters, and TIPS procedures. Considering the fast progress being made in this field, there can be no question that interventional MRI will become a well-accepted clinical tool offering potential advantages such as excellent soft tissue contrast, multiplanar imaging, flow measurements, high resolution imaging of vessel walls, and lack of ionizing radiation. (orig.) [German] Zur Durchfuehrung MR-gesteuerter Interventionen muessen interventionelle Instrumente gut sichtbar, aber ohne stoerende Artefakte darstellbar sein. Die Geschwindigkeit der Bilderstellung sollte fuer nichtvaskulaere Interventionen im Sekundenbereich liegen und fuer vaskulaere Interventionen Echtzeitbildgebung liefern. Weder

  2. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  3. Non-pharmacological interventions for treating chronic prostatitis/chronic pelvic pain syndrome.

    Science.gov (United States)

    Franco, Juan Va; Turk, Tarek; Jung, Jae Hung; Xiao, Yu-Tian; Iakhno, Stanislav; Garrote, Virginia; Vietto, Valeria

    2018-01-26

    Chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS) is a common disorder in which the two main clinical features are pelvic pain and lower urinary tract symptoms. There are currently many approaches for its management, using both pharmacological and non-pharmacological interventions. The National Institute of Health - Chronic Prostatitis Symptom Index (NIH-CPSI) score is a validated measure commonly used to measure CP/CPPS symptoms. To assess the effects of non-pharmacological therapies for chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS). We performed a comprehensive search using multiple databases, trial registries, grey literature and conference proceedings with no restrictions on the language of publication or publication status. The date of the latest search of all databases was August 2017. We included randomised controlled trials. Inclusion criteria were men with a diagnosis of CP/CPPS. We included all available non-pharmacological interventions. Two review authors independently classified studies and abstracted data from the included studies, performed statistical analyses and rated quality of evidence (QoE) according to the GRADE methods. We included 38 unique studies with 3290 men with CP/CPPS across 23 comparisons.1. Acupuncture: (three studies, 204 participants) based on short-term follow-up, acupuncture reduces prostatitis symptoms in an appreciable number of participants compared with sham procedure (mean difference (MD) in total NIH-CPSI score -5.79, 95% confidence interval (CI) -7.32 to -4.26, high QoE). Acupuncture likely results in little to no difference in adverse events (moderate QoE). It probably also decreases prostatitis symptoms compared with standard medical therapy in an appreciable number of participants (MD -6.05, 95% CI -7.87 to -4.24, two studies, 78 participants, moderate QoE).2. Circumcision: (one study, 713 participants) based on short-term follow-up, early circumcision probably decreases prostatitis symptoms

  4. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  5. MR-guided focused ultrasound. Current and future applications; MR-gesteuerter fokussierter Ultraschall. Aktuelle und potenzielle Indikationen

    Energy Technology Data Exchange (ETDEWEB)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen-Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Napoli, A. [Sapienza Universitaet Rom, Abteilung fuer Radiologie (Department of Radiological Sciences), MRgFUS and Cardiovascular Imaging Unit, Rom (Italy); Matzko, M. [Klinikum Dachau, Abteilung fuer diagnostische und interventionelle Radiologie, Dachau (Germany)

    2013-03-15

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [German] MRT-gesteuerter hochintensiver fokussierter Ultraschall (MRgFUS bzw. MR-HIFU) ist ein nichtinvasives Verfahren zur praezisen Thermoablation eines Zielgewebes. Bei dieser Methode werden benachbarte Gewebe und Organe geschont. Die Kombination des fokussierten Ultraschalls (FUS) mit der MRT zwecks Planung und Monitoring (nahezu) in Echtzeit sowie zur Erfolgskontrolle von Behandlungen traegt wesentlich zur Sicherheit dieser Methode bei. MRgFUS ist klinisch v. a. zur Behandlung von symptomatischen Uterusmyomen etabliert, gefolgt von der palliativen Ablation von Knochenmetastasen. Weitere vielversprechende Anwendungsgebiete des MRgFUS sind die Adenomyose des Uterus, die Behandlung von Prostata-, Mamma- und Lebertumoren sowie der intrakranielle Einsatz. (orig.)

  6. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  7. Contrast-enhanced versus systematic transrectal ultrasound-guided prostate cancer detection: An overview of techniques and a systematic review

    International Nuclear Information System (INIS)

    Heijmink, Stijn W.T.P.J.; Barentsz, Jelle O.

    2007-01-01

    An overview is given of the current conventional and contrast-specific transrectal ultrasound (TRUS) techniques for prostate imaging that may be used for guiding biopsy. Subsequently, a systematic literature search resulted in inclusion of four studies that directly compared systematic and contrast-enhanced-targeted TRUS-guided biopsy of the prostate. All four studies revealed that contrast-enhanced-targeted TRUS-guided biopsy significantly improved the positive biopsy core rate. In the largest study, the mean Gleason score of the contrast-enhanced-targeted TRUS-guided biopsies was significantly higher than that of the systematic biopsies. Future randomized clinical trials, preferably in a non-academic multi-institutional set-up, will have to be performed to confirm the value of contrast-enhanced-targeted TRUS-guided biopsy in regular clinical practice

  8. Atlas-guided prostate intensity modulated radiation therapy (IMRT) planning

    International Nuclear Information System (INIS)

    Sheng, Yang; Li, Taoran; Zhang, You; Lee, W Robert; Yin, Fang-Fang; Wu, Q Jackie; Ge, Yaorong

    2015-01-01

    An atlas-based IMRT planning technique for prostate cancer was developed and evaluated. A multi-dose atlas was built based on the anatomy patterns of the patients, more specifically, the percent distance to the prostate and the concaveness angle formed by the seminal vesicles relative to the anterior-posterior axis. A 70-case dataset was classified using a k-medoids clustering analysis to recognize anatomy pattern variations in the dataset. The best classification, defined by the number of classes or medoids, was determined by the largest value of the average silhouette width. Reference plans from each class formed a multi-dose atlas. The atlas-guided planning (AGP) technique started with matching the new case anatomy pattern to one of the reference cases in the atlas; then a deformable registration between the atlas and new case anatomies transferred the dose from the atlas to the new case to guide inverse planning with full automation. 20 additional clinical cases were re-planned to evaluate the AGP technique. Dosimetric properties between AGP and clinical plans were evaluated. The classification analysis determined that the 5-case atlas would best represent anatomy patterns for the patient cohort. AGP took approximately 1 min on average (corresponding to 70 iterations of optimization) for all cases. When dosimetric parameters were compared, the differences between AGP and clinical plans were less than 3.5%, albeit some statistical significances observed: homogeneity index (p  >  0.05), conformity index (p  <  0.01), bladder gEUD (p  <  0.01), and rectum gEUD (p  =  0.02). Atlas-guided treatment planning is feasible and efficient. Atlas predicted dose can effectively guide the optimizer to achieve plan quality comparable to that of clinical plans. (paper)

  9. Percutaneous cryoablation of prostate cancer guided by rectal ultrasound: a retrospectively analysis of 42 cases

    International Nuclear Information System (INIS)

    Xing Wenge; Guo Zhi; Wang Haitao; Liu Fang; Li Baoguo; Yu Haipeng; Li Yong

    2008-01-01

    Objective: To evaluate the effectiveness and safety of rectal ultrasound-guided agon-hilium percutaneous cryoablation in treatment of patients with median and or late-stage prostate cancer patients. Methods: Retrospectively analysis of 42 cases of with stage C and D prostate cancer patients treated by rectal ultrasound-guided argon-hilium percutaneous cryoablation during the follow-up of 1-12 months. The prostate specific antigen (PSA), biochemical progression-free survival (bPFS), PSA objective response, transrectal ultrasound of the prostate (TRUS), TRUS-guided biopsy of the prostate, the maximum urinary flow rate(MFR), MRI examination at before, and 3,6,12 months after cryoablation were recorded and evaluated. The results were statistically evaluated by using variance analysis. Results: The PSA value at before and 3,6, 12 months after cryoablation were (4.48±1.35), (3.54±1.67), (3.18±1.76), (2.87±1.89) μg/L, respectively; TRUS-measured prostate volumes at before and 3, 6,12 months after cryoablation were (59.7± 8.2), (46.9±8.3), (26.2±3.9), (25.9±3.7) mm 3 , respectively; MFR before and 3, 6,12 months after cryoablation were (10.4±0.8), (14.3±1.2), (18.3±1.3), (18.9±1.3) ml/s, respectively; Compared with before cryoablation, the differences between before and after cryoablation was statistically significant (F= 53.93,747.92,3843.03, respectively, P<0.01). The bPFS rates in 3 months,6 months and 12 months were 95.2% (40/42), 95.2% (40/42), and 90.5% (38/42), respectively. According to the PSA response, the total effective rate (CR 16 cases, PR 15 cases) at 12 months was 73.8%, and SD was 16.7% (7/42), PD was 9.5% (4/42). Complications included temporary incontinence 2.4% (1/42), Penile tingling/numbness 2.4% (1/42), pelvic pain 4.9% (2/41) and Scrotum Edema 2.4% (1/42). There was no case with severe complications such as severe infection or urethrorectal fistula, etc. Conclusions: Rectal ultrasound-guided agon-hilium percutaneous cryoablation showed

  10. Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

    International Nuclear Information System (INIS)

    Su Zhong; Zhang Lisha; Murphy, Martin; Williamson, Jeffrey

    2011-01-01

    Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for ≥91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the

  11. Oligonodular hepatocellular carcinoma (HCC): MR-guided laser-induced thermotherapy (LITT)

    International Nuclear Information System (INIS)

    Eichler, K.; Mack, M.G.; Straub, R.; Engelmann, K.; Zangos, S.; Woitaschek, D.; Vogl, T.J.

    2001-01-01

    Purpose. To prospectively evaluate the therapeutic potential of MR-guided laser-induced thermotherapy (LITT) in patients with oligonodular hepatocellular carcinoma. Material and methods. 39 patients with 61 intrahepatic lesions were treated with LITT. The Nd:YAG laser fiber was introduced with a percutaneously positioned irrigated laser application system. Qualitative and quantitative MR parameters and clinical data were evaluated. Results. All patients tolerated the procedure well under local anesthesia. All observed complications were minor and no further treatment was necessary. Online MR thermometry allowed exact visualization. Lesions p to 2 cm in diameter could be efficiently treated with a single laser application, larger lesions were treated simultaneous multiapplication. In 97.5% we achieved a complete necrosis of the tumor and a 5 mm safety margin, resulting in a complete destruction of the tumor without local recurrences. Mean survival was 4.4 years (95% Cl: 3.6-5.2 years) after the time of diagnoses of the HCC (Kaplan-Meier-method). Conclusion. In intrahepatic oligonodular involvement of hepatocellular carcinoma LITT appears to be an effective therapeutic procedure with a high tumor contol rate and better survival data. (orig.) [de

  12. Dietary intervention strategies to modulate prostate cancer risk and prognosis.

    Science.gov (United States)

    Freedland, Stephen J; Aronson, William J

    2009-05-01

    There is increasing interest in complementary and holistic approaches for cancer prevention and management. We sought to review the latest literature regarding dietary interventions for prostate cancer with a special emphasis on dietary fat and carbohydrate intake for modulating prognosis among men with prostate cancer. Several recent prospective trials have investigated various dietary and lifestyle investigations on malignant prostate tissue biology. These interventions included a very low-fat (12% fat kcals) vegan diet with various supplements and lifestyle changes, a more traditional low-fat diet (25% fat kcals) with flaxseed supplementation, and a low-glycemic index diet. Low-glycemic index and very low-fat vegan diets (with supplements and lifestyle changes) alter tumor biology as assessed by tumor gene expression changes, with a common mechanism perhaps being weight loss whereas no effects were seen with a traditional low-fat diet. In mice, either very low-fat or low-carbohydrate diets significantly slow tumor growth independent of weight loss. Epidemiologic and preclinical data also suggest cholesterol intake and serum cholesterol levels may be linked with the development and progression of prostate cancer. Small clinical trials suggest that tumor biology can be altered by either a vegan low-fat diet or eliminating simple carbohydrates accompanied by weight loss. Larger and longer term studies are needed to determine the clinical relevance of these findings.

  13. A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI.

    Science.gov (United States)

    Bohning, Daryl E; Denslow, S; Bohning, P A; Walker, J A; George, M S

    2003-11-01

    Transcranial magnetic stimulation (TMS) can be interleaved with fMRI to visualize regional brain activity in response to direct, non-invasive, cortical stimulation, making it a promising tool for studying brain function. A major practical difficulty is accurately positioning the TMS coil within the MRI scanner for stimulating a particular area of brain cortex. The objective of this work was to design and build a self-contained hardware/software system for MR-guided TMS coil positioning in interleaved TMS/fMRI studies. A compact, manually operated, articulated TMS coil positioner/holder with 6 calibrated degrees of freedom was developed for use inside a cylindrical RF head coil, along with a software package for transforming between MR image coordinates, MR scanner space coordinates, and positioner/holder settings. Phantom calibration studies gave an accuracy for positioning within setups of dx=+/-1.9 mm, dy=+/-1.4 mm, dz=+/-0.8 mm and a precision for multiple setups of dx=+/-0.8 mm, dy=+/-0.1 mm, dz=+/-0.1 mm. This self-contained, integrated MR-guided TMS system for interleaved TMS/fMRI studies provides fast, accurate location of motor cortex stimulation sites traditionally located functionally, and a means of consistent, anatomy-based TMS coil positioning for stimulation of brain areas without overt response.

  14. [Musculoskeletal biopsies in an open 0.5-T-MR system].

    Science.gov (United States)

    Pretzsch, M; Scholz, R; Moche, M; Thomas, M; Tannapfel, A; von Salis-Soglio, G

    2005-01-01

    MR-guided interventions have been successful in different medical disciplines. The aim of this paper is to report our results with the application of MR-guided biopsies of musculoskeletal lesions using an open 0.5-T-MR scanner and further to discuss these results on the basis of the available literature. Between 1998 and 2003 30 patients (average age 44.1 years) underwent a total of 31 biopsies. The interventions were performed in an open 0.5-T MRI system using an active optical localization system as well as a navigation system. For the motion tracking we used T (1)-weighted real-time sequences with 0.25 pictures per second. For the sampling MR-compatible instruments were used that were specially developed for this purpose. The data of this retrospective investigation are based on the evaluation of the patient documents and the radiological findings. On the basis of the histological findings the technical success rate and the histological overall accuracy were determined. In 81 % of the biopsies the histological diagnosis was correct. In cases of suspected inflammation the histological accuracy was smaller (70 %). No differences were observed between skeletal and soft-tissue lesions. The technical success rate amounted to 77.5 %. No procedural or anesthesiological complications occurred. The mean operating time amounted to 65 min including the time for motion tracking. In cases of suspected lesions of the musculoskeletal system, the MR-guided biopsy represents a promising and safe procedure to get a histological diagnosis. In cases of sufficient size of the lesion sampling of a representative probe is possible. On account of the outstanding performance in soft-part contrasting, the sensitive structures surrounding the lesion can be saved. Substantial disadvantages of the procedure are the high costs for personal and material and the long operating time.

  15. Comparison of manual and automatic MR‐CT registration for radiotherapy of prostate cancer

    Science.gov (United States)

    Carl, Jesper; Østergaard, Lasse Riis

    2016-01-01

    In image‐guided radiotherapy (IGRT) of prostate cancer, delineation of the clinical target volume (CTV) often relies on magnetic resonance (MR) because of its good soft‐tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR‐CT registration of the prostate has previously been developed using a voxel property‐based registration as an alternative to a manual landmark‐based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni‐Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80 mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration. PACS number(s): 87.57.nj, 87.61.‐c, 87.57.Q‐, 87.56.J‐ PMID:27167285

  16. MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Hricak, H.

    1987-01-01

    MR imaging, CT, and US should be viewed as complementary studies for imaging the pelvis. MR imaging is relatively expensive, not widely available, and requires special facilities. However, it is noninvasive and offers a large field-of-view, direct imaging in all three orthogonal planes and excellent soft-tissue contrast. Surgical clips, which present a problem with other imaging modalities, do not create significant MR image artifacts. Image degradation due to bowel motion can be minimized by bowel preparation and/or the administration of glucagon. The value of MR imaging of the pelvis is in staging rather than diagnosis of pelvic neoplasms. The accuracy, sensitivity, and specificity of MR imaging in staging prostate or bladder tumors exceed those of US and CT. In prostate carcinoma, MR imaging can be used to evaluate periprostatic tumor extension, especially to the bladder base, rectum, or seminal vesicles. For early transcapsular extension, however, the accuracy of transrectal US reportedly surpasses that of MR imaging. In bladder carcinoma, the value of MR imaging is in direct tumor visualization, the ability to differentiate between tumor and normal bladder wall, and the evaluation of bladder tumors located at the dome of the bladder base, where imaging in the sagittal plane is essential. In the evaluation of benign entities of the female pelvis, US remains the preferred screening modality. The use of MR imaging is reserved for cases of infertility or for planning myomectomy when knowledge of the exact number, size, and location of tumors is essential. MR imaging is useful in evaluating patients with amenorrhea or any suspected congenital anomalies. The main application of MR imaging of the female pelvis is in the staging of neoplasms, including endometrial and cervical carcinomas

  17. [Laparoscopic and general surgery guided by open interventional magnetic resonance].

    Science.gov (United States)

    Lauro, A; Gould, S W T; Cirocchi, R; Giustozzi, G; Darzi, A

    2004-10-01

    Interventional magnetic resonance (IMR) machines have produced unique opportunity for image-guided surgery. The open configuration design and fast pulse sequence allow virtual real time intraoperative scanning to monitor the progress of a procedure, with new images produced every 1.5 sec. This may give greater appreciation of anatomy, especially deep to the 2-dimensional laparoscopic image, and hence increase safety, reduce procedure magnitude and increase confidence in tumour resection surgery. The aim of this paper was to investigate the feasibility of performing IMR-image-guided general surgery, especially in neoplastic and laparoscopic field, reporting a single center -- St. Mary's Hospital (London, UK) -- experience. Procedures were carried out in a Signa 0.5 T General Elettric SP10 Interventional MR (General Electric Medical Systems, Milwaukee, WI, USA) with magnet-compatible instruments (titanium alloy instruments, plastic retractors and ultrasonic driven scalpel) and under general anesthesia. There were performed 10 excision biopsies of palpable benign breast tumors (on female patients), 3 excisions of skin sarcoma (dermatofibrosarcoma protuberans), 1 right hemicolectomy and 2 laparoscopic cholecystectomies. The breast lesions were localized with pre- and postcontrast (intravenous gadolinium DPTA) sagittal and axial fast multiplanar spoiled gradient recalled conventional Signa sequences; preoperative real time fast gradient recalled sequences were also obtained using the flashpoint tracking device. During right hemicolectomy intraoperative single shot fast spin echo (SSFSE) and fast spoiled gradient recalled (FSPGR) imaging of right colon were performed after installation of 150 cc of water or 1% gadolinium solution, respectively, through a Foley catheter; imaging was also obtained in an attempt to identify mesenteric lymph nodes intraoperatively. Concerning laparoscopic procedures, magnetic devices (insufflator, light source) were positioned outside scan

  18. Ultrasonically guided 125iodine seed implantation with external radiation in management of localized prostatic carcinoma

    DEFF Research Database (Denmark)

    Iversen, P; Bak, M; Juul, N

    1989-01-01

    Thirty-three patients with localized prostatic carcinoma (16 poorly differentiated) were treated with transperineal 125Iodine seed implantation (160 Gy) guided by transrectal ultrasonography and subsequent external beam irradiation (47.4 Gy). The observation time was six to sixty-eight months...... with a median follow-up of thirty-five months. Median change in prostatic volume was a reduction of 35 percent. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after one to two years, revealing still malignant histology in 12 (48%). Development of distant metastases occurred...

  19. MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Huang, Jie; Xu, Yujun; He, Xiangmeng; Lue, Yubo; Liu, Qiang; Li, Chengli [Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong (China); Li, Lei [Qingdao Central Hospital, Department of Interventional Radiology, Qingdao, Shandong (China); Blanco Sequeiros, Roberto [Turku University Hospital, The South Western Finland Imaging Centre, Turku (Finland)

    2017-04-15

    To prospectively evaluate the feasibility, safety and accuracy of MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open MR scanner with respiratory gating. Sixty-five patients with 65 solitary pulmonary lesions underwent MR-guided percutaneous coaxial cutting needle biopsy using a 1.0-T open MR scanner with respiratory gating. Lesions were divided into two groups according to maximum lesion diameters: ≤2.0 cm (n = 31) and >2.0 cm (n = 34). The final diagnosis was established in surgery and subsequent histology. Diagnostic accuracy, sensitivity and specificity were compared between the groups using Fisher's exact test. Accuracy, sensitivity and specificity of MRI-guided percutaneous pulmonary biopsy in diagnosing malignancy were 96.9 %, 96.4 % and 100 %, respectively. Accuracy, sensitivity and specificity were 96.8 %, 96.3 % and 100 % for lesions 2.0 cm or smaller and 97.1 %, 96.4 % and 100 %, respectively, for lesions larger than 2.0 cm. There was no significant difference between the two groups (P > 0.05). Biopsy-induced complications encountered were pneumothorax in 12.3 % (8/65) and haemoptysis in 4.6 % (3/65). There were no serious complications. MRI-guided percutaneous biopsy using a 1.0-T open MR scanner with respiratory gating is an accurate and safe diagnostic technique in evaluation of pulmonary lesions. (orig.)

  20. Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan [Eberhard Karls University of Tuebingen, Department on Diagnostic and Interventional Radiology, Tuebingen (Germany); Roland, Joerg; Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany); Pereira, Philippe L. [Clinic for radiology, Nuclear Medicine and Minimal Invasive Therapies, SLK-Clinics, Heilbronn (Germany)

    2012-05-15

    To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 {+-} 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)

  1. Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours

    International Nuclear Information System (INIS)

    Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan; Roland, Joerg; Kickhefel, Antje; Pereira, Philippe L.

    2012-01-01

    To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 ± 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)

  2. Use of MRI in interventions in head and neck surgery

    International Nuclear Information System (INIS)

    Schulz, T.; Schneider, J.P.; Schmidt, F.; Kahn, T.; Bootz, F.; Weber, A.; Weidenbach, H.; Heinke, W.; Koehler-Brock, A.

    2001-01-01

    Presentation of new concepts and applications of MR-guided head and neck surgery are presented. Examples of diagnostic and therapeutic procedures such as evaluation of transseptal tumor biopsies, placement of afterloading catheters for brachytherapy, and microscopic surgery of paranasal sinuses in the open MRI are discussed. Material and Methods: 24 MRI-guided ENT-procedures (14 transsphenoidal biopsies, one transnasal biopsy, 6 placements of brachytherapy catheters, and 3 operations of the paranasal sinuses) were performed in an open 0.5 T MR system. Results: localisation and/or extension of all lesions as well as the placement of biopsy needles or catheters were determined with great precision during the interventions. Conclusions: surgical risk and postoperative morbidity are significantly reduced in MR-guided surgery of the petroclival region and the region of head and neck compared to other, conventional methods. Thus, interventional MRI-guidance optimizes minimal invasive surgery and catheter placement in difficult anatomical regions like the petroclival region. (orig.) [de

  3. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  4. Differentiation of prostatitis and prostate cancer using the Prostate Imaging-Reporting and Data System (PI-RADS).

    Science.gov (United States)

    Meier-Schroers, Michael; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Traeber, Frank; Sprinkart, Alois Martin; Block, Wolfgang; Schild, Hans Heinz; Willinek, Winfried

    2016-07-01

    To determine if prostate cancer (PCa) and prostatitis can be differentiated by using PI-RADS. 3T MR images of 68 patients with 85 cancer suspicious lesions were analyzed. The findings were correlated with histopathology. T2w imaging (T2WI), diffusion weighted imaging (DWI), dynamic contrast enhancement (DCE), and MR-Spectroscopy (MRS) were acquired. Every lesion was given a single PI-RADS score for each parameter, as well as a sum score and a PI-RADS v2 score. Furthermore, T2-morphology, ADC-value, perfusion type, citrate/choline-level, and localization were evaluated. 44 of 85 lesions showed PCa (51.8%), 21 chronic prostatitis (24.7%), and 20 other benign tissue such as hyperplasia or fibromuscular tissue (23.5%). The single PI-RADS score for T2WI, DWI, DCE, as well as the aggregated score including and not including MRS, and the PI-RADS v2-score were all significantly higher for PCa than for prostatitis or other tissue (pprostatitis than for other tissue (p=0.029 and p=0.020), whereas the other parameters were not different. Prostatitis usually presented borderline pathological PI-RADS scores, showed restricted diffusion with ADC≥900mm(2)/s in 100% of cases, was more often indistinctly hypointense on T2WI (66.7%), and localized in the transitional zone (57.1%). An ADC≥900mm(2)/s achieved the highest predictive value for prostatitis (AUC=0.859). Prostatitis can be differentiated from PCa using PI-RADS, since all available parameters are more distinct in cases of cancer. However, there is significant overlap between prostatitis and other benign findings, thus PI-RADS is only suitable to a limited extent for the primary assessment of prostatitis. Restricted diffusion with ADC≥900mm(2)/s is believed to be a good indicator for prostatitis. MRS can help to distinguish between prostatitis and other tissue. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Workflow and intervention times of MR-guided focused ultrasound - Predicting the impact of new techniques.

    Science.gov (United States)

    Loeve, Arjo J; Al-Issawi, Jumana; Fernandez-Gutiérrez, Fabiola; Langø, Thomas; Strehlow, Jan; Haase, Sabrina; Matzko, Matthias; Napoli, Alessandro; Melzer, Andreas; Dankelman, Jenny

    2016-04-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has become an attractive, non-invasive treatment for benign and malignant tumours, and offers specific benefits for poorly accessible locations in the liver. However, the presence of the ribcage and the occurrence of liver motion due to respiration limit the applicability MRgFUS. Several techniques are being developed to address these issues or to decrease treatment times in other ways. However, the potential benefit of such improvements has not been quantified. In this research, the detailed workflow of current MRgFUS procedures was determined qualitatively and quantitatively by using observation studies on uterine MRgFUS interventions, and the bottlenecks in MRgFUS were identified. A validated simulation model based on discrete events simulation was developed to quantitatively predict the effect of new technological developments on the intervention duration of MRgFUS on the liver. During the observation studies, the duration and occurrence frequencies of all actions and decisions in the MRgFUS workflow were registered, as were the occurrence frequencies of motion detections and intervention halts. The observation results show that current MRgFUS uterine interventions take on average 213min. Organ motion was detected on average 2.9 times per intervention, of which on average 1.0 actually caused a need for rework. Nevertheless, these motion occurrences and the actions required to continue after their detection consumed on average 11% and up to 29% of the total intervention duration. The simulation results suggest that, depending on the motion occurrence frequency, the addition of new technology to automate currently manual MRgFUS tasks and motion compensation could potentially reduce the intervention durations by 98.4% (from 256h 5min to 4h 4min) in the case of 90% motion occurrence, and with 24% (from 5h 19min to 4h 2min) in the case of no motion. In conclusion, new tools were developed to predict how

  6. Endovascular image-guided interventions (EIGIs)

    International Nuclear Information System (INIS)

    Rudin, Stephen; Bednarek, Daniel R.; Hoffmann, Kenneth R.

    2008-01-01

    Minimally invasive interventions are rapidly replacing invasive surgical procedures for the most prevalent human disease conditions. X-ray image-guided interventions carried out using the insertion and navigation of catheters through the vasculature are increasing in number and sophistication. In this article, we offer our vision for the future of this dynamic field of endovascular image-guided interventions in the form of predictions about (1) improvements in high-resolution detectors for more accurate guidance, (2) the implementation of high-resolution region of interest computed tomography for evaluation and planning, (3) the implementation of dose tracking systems to control patient radiation risk, (4) the development of increasingly sophisticated interventional devices, (5) the use of quantitative treatment planning with patient-specific computer fluid dynamic simulations, and (6) the new expanding role of the medical physicist. We discuss how we envision our predictions will come to fruition and result in the universal goal of improved patient care.

  7. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  8. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  9. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    International Nuclear Information System (INIS)

    Deng Jun; Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior–inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT–contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  10. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun, E-mail: jun.deng@yale.edu [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States); Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States)

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  11. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Guide for intervention levels in radiological accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tai; Khang, Byung Oui; Lee, Goan Yup; Han, Gee Yang [Korea Atomic Energy Resesrch Institute, Taejon (Korea, Republic of)

    2001-03-15

    Based on IAEA SS109 and ICRP63, intervention levels and action levels are derived using cost-benefit approach method. Intervention levels are optimized so that the net benefit from protective measures will be maximized. Evacuation, sheltering, relocation, permanent resettlement, administration of stable iodine and food restriction are included in protective measures. Intervention levels are calculated using site specific parameters in Korea. As a results of calculation, general intervention levels are similar to IAEA recommendation and action levels for food restriction are a little higher than IAEA recommendation and Japan guide. Guide on intervention levels in Korea is also suggested based on the calculated results.

  13. MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Schernthaner, Melanie; Pinker, Katja; Kapetas, Panagiotis; Bernathova, Maria; Polanec, Stephan H.; Bickel, Hubert; Wengert, Georg J.; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2016-11-15

    The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients underwent 487 MR-guided VABB using three different 8-10-gauge-VABB devices (Atec-9-gauge,A; Mammotome-8-gauge,M; Vacora-10-gauge,V). VABB data (lesion-type, size, biopsy device, histopathology) were compared to final diagnosis (surgery, n = 210 and follow-up, n = 277). Chi-square, and Kruskal-Wallis tests were applied. P values < 0.05 were considered significant. Final diagnosis was malignant in 104 (21.4 %), high risk in 64 (13.1 %) and benign in 319 (65.5 %) cases. Eleven of 328 (3.4 %) benign-rated lesions were false-negative (1/95, 1.1 %, A; 2/73, 2.7 %, M; 8/160 5.0 % V; P = 0.095). Eleven high-risk (11/77, 14.3 %) lesions proved to be malignant (3/26, 11.5 % A; 4/12, 33.3 % M; 4/39, 10.3 % V; P = 0.228). Five of 34 (14.7 %) DCIS were upgraded to invasive cancer (2/15, 13.3 %, A; 1/6, 16.6 % M; 2/13, 15.3 %, V; P = 0.977). Lesion size (P = 0.05) and type (mass vs. non-mass, P = 0.107) did not differ significantly. MR-guided VABB is an accurate method for diagnosis of MRI-only lesions. No significant differences on false-negative and underestimation rates were observed between three different biopsy devices. (orig.)

  14. In-bore setup and software for 3T MRI-guided transperineal prostate biopsy

    International Nuclear Information System (INIS)

    Tokuda, Junichi; Tuncali, Kemal; Song, Sang-Eun; Fedorov, Andriy; Oguro, Sota; Fennessy, Fiona M; Tempany, Clare M; Hata, Nobuhiko; Iordachita, Iulian; Lasso, Andras

    2012-01-01

    MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support MRI-guided transperineal prostate biopsy in a wide-bore 3 T MRI scanner. The setup consists of a specially designed tabletop and a needle-guiding template with a Z-frame that gives a physician access to the perineum of the patient at the imaging position and allows the physician to perform MRI-guided transperineal biopsy without moving the patient out of the scanner. The software and Z-frame allow registration of the template, target planning and biopsy guidance. Initially, we performed phantom experiments to assess the accuracy of template registration and needle placement in a controlled environment. Subsequently, we embarked on our clinical trial (N = 10). The phantom experiments showed that the translational errors of the template registration along the right–left (RP) and anterior–posterior (AP) axes were 1.1 ± 0.8 and 1.4 ± 1.1 mm, respectively, while the rotational errors around the RL, AP and superior–inferior axes were (0.8 ± 1.0)°, (1.7 ± 1.6)° and (0.0 ± 0.0)°, respectively. The 2D root-mean-square (RMS) needle-placement error was 3 mm. The clinical biopsy procedures were safely carried out in all ten clinical cases with a needle-placement error of 5.4 mm (2D RMS). In conclusion, transperineal prostate biopsy in a wide-bore 3T scanner is feasible using our custom-made tabletop setup and software, which supports manual needle placement without moving the patient out of the magnet. (paper)

  15. Influence of volumes of prostate, rectum, and bladder on treatment planning CT on interfraction prostate shifts during ultrasound image-guided IMRT

    International Nuclear Information System (INIS)

    Reddy, Nandanuri M. S.; Nori, Dattatreyudu; Sartin, William; Maiorano, Samuel; Modena, Jennifer; Mazur, Andrej; Osian, Adrian; Sood, Brijmohan; Ravi, Akkamma; Sampath, Seshadri; Lange, Christopher S.

    2009-01-01

    Purpose: The purpose of this study was to analyze the relationship between prostate, bladder, and rectum volumes on treatment planning CT day and prostate shifts in the XYZ directions on treatment days. Methods: Prostate, seminal vesicles, bladder, and rectum were contoured on CT images obtained in supine position. Intensity modulated radiation therapy plans was prepared. Contours were exported to BAT-ultrasound imaging system. Patients were positioned on the couch using skin marks. An ultrasound probe was used to obtain ultrasound images of prostate, bladder, and rectum, which were aligned with CT images. Couch shifts in the XYZ directions as recommended by BAT system were made and recorded. 4698 couch shifts for 42 patients were analyzed to study the correlations between interfraction prostate shifts vs bladder, rectum, and prostate volumes on planning CT. Results: Mean and range of volumes (cc): Bladder: 179 (42-582), rectum: 108 (28-223), and prostate: 55 (21-154). Mean systematic prostate shifts were (cm, ±SD) right and left lateral: -0.047±0.16 (-0.361-0.251), anterior and posterior: 0.14±0.3 (-0.466-0.669), and superior and inferior: 0.19±0.26 (-0.342-0.633). Bladder volume was not correlated with lateral, anterior/posterior, and superior/inferior prostate shifts (P>0.2). Rectal volume was correlated with anterior/posterior (P 0.2). The smaller the rectal volume or cross sectional area, the larger was the prostate shift anteriorly and vice versa (P 0.2). The smaller the prostate volume, the larger was prostate shift superiorly and vice versa (P<0.05). Conclusions: Prostate and rectal volumes, but not bladder volumes, on treatment planning CT influenced prostate position on treatment fractions. Daily image-guided adoptive radiotherapy would be required for patients with distended or empty rectum on planning CT to reduce rectal toxicity in the case of empty rectum and to minimize geometric miss of prostate.

  16. Toxicity after intensity-modulated, image-guided radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Flentje, Michael; Guckenberger, Matthias; Ok, Sami; Polat, Buelent; Sweeney, Reinhart A.

    2010-01-01

    Purpose: To evaluate toxicity after dose-escalated radiotherapy for prostate cancer using intensity-modulated treatment planning (IMRT) and image-guided treatment (IGRT) delivery. Patients and Methods: 100 patients were treated with simultaneous integrated boost (SIB) IMRT for prostate cancer: doses of 76.23 Gy and 60 Gy in 33 fractions were prescribed to the prostate and the seminal vesicles, respectively, for intermediate- and high-risk patients (n = 74). The total dose was 73.91 Gy in 32 fractions for low-risk patients and after transurethral resection of the prostate (n = 26). The pelvic lymphatics were treated with 46 Gy in 25 fractions in patients with high risk of lymph node metastases using an SIB to the prostate (n = 25). IGRT was practiced with cone-beam computed tomography. Acute and late gastrointestinal (GI) and genitourinary (GU) toxicity was evaluated prospectively (CTCAE v3.0). Results: Treatment was completed as planned by all patients. Acute GI and GU toxicity grade ≥ 2 was observed in 12% and 42% of the patients, respectively, with 4% suffering from GU toxicity grade 3. 6 weeks after treatment, the incidence of acute toxicity grade ≥ 2 had decreased to 12%. With a median follow-up of 26 months, late GI and GU toxicity grade ≥ 2 was seen in 1.5% and 7.7% of the patients at 24 months. Four patients developed late toxicity grade 3 (GI n = 1; GU n = 3). Presence of acute GI and GU toxicity was significantly associated with late GI (p = 0.0007) and GU toxicity (p = 0.006). Conclusion: High-dose radiotherapy for prostate cancer using IMRT and IGRT resulted in low rates of acute toxicity and preliminary results of late toxicity are promising. (orig.)

  17. Toxicity after intensity-modulated, image-guided radiotherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Flentje, Michael [Dept. of Radiotherapy, Univ. Hospital Wuerzburg (Germany); Guckenberger, Matthias; Ok, Sami; Polat, Buelent; Sweeney, Reinhart A.

    2010-10-15

    Purpose: To evaluate toxicity after dose-escalated radiotherapy for prostate cancer using intensity-modulated treatment planning (IMRT) and image-guided treatment (IGRT) delivery. Patients and Methods: 100 patients were treated with simultaneous integrated boost (SIB) IMRT for prostate cancer: doses of 76.23 Gy and 60 Gy in 33 fractions were prescribed to the prostate and the seminal vesicles, respectively, for intermediate- and high-risk patients (n = 74). The total dose was 73.91 Gy in 32 fractions for low-risk patients and after transurethral resection of the prostate (n = 26). The pelvic lymphatics were treated with 46 Gy in 25 fractions in patients with high risk of lymph node metastases using an SIB to the prostate (n = 25). IGRT was practiced with cone-beam computed tomography. Acute and late gastrointestinal (GI) and genitourinary (GU) toxicity was evaluated prospectively (CTCAE v3.0). Results: Treatment was completed as planned by all patients. Acute GI and GU toxicity grade {>=} 2 was observed in 12% and 42% of the patients, respectively, with 4% suffering from GU toxicity grade 3. 6 weeks after treatment, the incidence of acute toxicity grade {>=} 2 had decreased to 12%. With a median follow-up of 26 months, late GI and GU toxicity grade {>=} 2 was seen in 1.5% and 7.7% of the patients at 24 months. Four patients developed late toxicity grade 3 (GI n = 1; GU n = 3). Presence of acute GI and GU toxicity was significantly associated with late GI (p = 0.0007) and GU toxicity (p = 0.006). Conclusion: High-dose radiotherapy for prostate cancer using IMRT and IGRT resulted in low rates of acute toxicity and preliminary results of late toxicity are promising. (orig.)

  18. Use of CT or MR dosimetry in high dose rate (HDR) brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Liu, C.; Das, R.; See, A.; Duchesne, G.M.; Van Dyk, S.; Tai, K.H.

    2003-01-01

    Brachytherapy (BT) has, in recent years, become a well-utilised treatment option for prostate cancer. Tumour control probability relies on accurate dosimetry, which in turn relies on the accurate definition of the prostate gland. In external beam radiotherapy and BT, MRI has been shown to be a superior imaging modality when delineating the prostate gland especially at the apex. To date, data on MRI planning in prostate BT has focussed mainly on permanent interstitial implants. No data currently exists comparing MRI vs CT planning in HDR BT and its subsequent impact on prostate dosimetry. To determine the effects of MRI vs CT in HDR BT with respect to prostatic volumes and normal tissue doses, with the evaluations made using dose-volume histograms (DVH). Dosimetry parameters derived using CT and MRI (T2 weighted) scans of 11 patients who had received TRUS guided implants for HDR BT, were compared using the PlatoTM computer planning system. Treatment plans were generated on volumes marked by the same radiation oncologist for each patient. Comparison was made of the treatment plans (dosimetry) between: 1. CT generated plans; 2. CT generated plans assessed using MRI marked volumes and 3. MRI generated plans. We confirm the previously reported results that CT scans can overestimate prostatic volumes compared with MRI. Variations were noted in CT and MRI based plans that may allow improved sparing of the rectum and urethra when using MRI planning. The main disadvantages of using MRI scans are access to facilities as well as identifying a dummy source to adequately define the tips of our catheters. It is feasible to utilise MRI scans for HDR BT planning. The clearer definition of anatomical structures has added advantages when contouring the prostate

  19. Image-Guided Hypofractionated Radiotherapy in Low-Risk Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Maurizio Valeriani

    2014-01-01

    Full Text Available Aim. To evaluate efficacy and toxicity of image-guided hypofractionated radiotherapy (HFRT in the treatment of low-risk prostate cancer. Outcomes and toxicities of this series of patients were compared to another group of 32 low-risk patients treated with conventional fractionation (CFRT. Methods. Fifty-nine patients with low-risk prostate cancer were analysed. Total dose for the prostate and proximal seminal vesicles was 60 Gy delivered in 20 fractions. Results. The median follow-up was 30 months. The actuarial 4-year overall survival, biochemical free survival, and disease specific survival were 100%, 97.4%, and 97.4%, respectively. Acute grade 1-2 gastrointestinal (GI and genitourinary (GU toxicity rates were 11.9% and 40.7%, respectively. Grade 1 GI and GU late toxicity rates were 8.5% and 13.6%, respectively. No grade ≥2 late toxicities were recorded. Acute grade 2-3 GU toxicity resulted significantly lower (P=0.04 in HFRT group compared to the CFRT group. The cumulative 4-year incidence of grade 1-2 GU toxicity was significantly higher (P<0.001 for HFRT patients. Conclusions. Our study demonstrated that hypofractionated regimen provided excellent biochemical control in favorable risk prostate cancer patients. The incidence of GI and GU toxicity was low. However, HFRT presented higher cumulative incidence of low-grade late GU toxicity than CFRT.

  20. Prostate embolization: A new acting field of interventional radiology

    International Nuclear Information System (INIS)

    Kisilevzky, N.; García Mónaco, R.; Peralta, O.; Rabelino, M.; Rosales Arroba, R.; Rodriguez, P.; Ocantos, J.; Martínez, P.F.; Damia, O.

    2014-01-01

    Purposes: To present the initial experience with prostatic embolization as an alternative treatment for benign prostatic hyperplasia (BPH) from a technical perspective to establish the contribution provided by diagnostic imaging. Materials and methods: Sixteen patients with lower urinary tract symptoms due to benign prostatic hyperplasia underwent prostatic embolization. All patients were evaluated with specific questionnaires to determine the severity of symptoms, impact on quality of life and erectile function, ultrasound and MRI of the pelvis, urinary flowmetry and PSA before and 30 days after the procedure. Results: Embolization was successful in all patients; in 10 cases the procedure was performed bilaterally and in six, only one side was embolized. The average time for completion of the procedure was 82 minutes and the average fluoroscopy time was 38.5 minutes. All procedures were performed on an outpatient basis with an average hospital stay of 6.4 hours. The mean contrast medium used was 175 ml. At 30 days there was a mean reduction on prostate volume of 21%. Clinical improvement was characterized by a mean 8-point improvement on IPSS, 2 points on QOL and 4 points on IIEF. The uroflowmetry improved 39% and PSA dropped 26%. No major complications that implied unscheduled hospitalization or performing additional surgical procedures were seen. Minor adverse events were verified in 9 patients. Conclusion: The initial results of prostatic embolization as an alternative treatment for BPH indicate that it is a safe and effective procedure to be consolidated as a new field of action of interventional radiology. (authors) [es

  1. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  2. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy.

    Science.gov (United States)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Joo; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-04-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08-7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT. © 2014 The Royal Australian and New Zealand College of Radiologists.

  3. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Jooh; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-01-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08–7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P < 0.05). The CTV-to-PTV margin necessary to allow for movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT.

  4. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  5. CT and MR image fusion using two different methods after prostate brachytherapy: impact on post-implant dosimetric assessment

    International Nuclear Information System (INIS)

    Servois, V.; El Khoury, C.; Lantoine, A.; Ollivier, L.; Neuenschwander, S.; Chauveinc, L.; Cosset, J.M.; Flam, T.; Rosenwald, J.C.

    2003-01-01

    To study different methods of CT and MR images fusion in patient treated by brachytherapy for localized prostate cancer. To compare the results of the dosimetric study realized on CT slices and images fusion. Fourteen cases of patients treated by 1125 were retrospectively studied. The CT examinations were realized with continuous section of 5 mm thickness, and MR images were obtained with a surface coil with contiguous section of 3 mm thickness. For the images fusion process, only the T2 weighted MR sequence was used. Two processes of images fusion were realized for each patient, using as reference marks the bones of the pelvis and the implanted seeds. A quantitative and qualitative appreciation was made by the operators, for each patient and both methods of images fusion. The dosimetric study obtained by a dedicated software was realized on CT images and all types of images fusion. The usual dosimetric indexes (D90, V 100 and V 150) were compared for each type of image. The quantitative results given by the software of images fusion showed a superior accuracy to the one obtained by the pelvic bony reference marks. Conversely, qualitative and quantitative results obtained by the operators showed a better accuracy of the images fusion based on iodine seeds. For two patients out of three presenting a D90 inferior to 145 Gy on CT examination, the D90 was superior to this norm when the dosimetry was based on images fusion, whatever the method used. The images fusion method based on implanted seed matching seems to be more precise than the one using bony reference marks. The dosimetric study realized on images fusion could allow to rectify possible errors, mainly due to difficulties in surrounding prostate contour delimitation on CT images. (authors)

  6. [Cost analysis of ultrasound-guided transrectal needle biopsy in prostatic carcinoma].

    Science.gov (United States)

    Bissoli, E; Fandella, A; La Torre, E; Faggiano, L; Anselmo, G; Frasson, F

    1998-04-01

    The literature mortality and morbidity rates from prostatic carcinoma prompt to the better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. We evaluated the overall cost of transrectal ultrasound biopsy (TRUSB) of the prostate and investigated the economic impact of the procedures currently used to diagnose prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 1996. The following cost factors were evaluated: personnel, materials, maintenance-equipment depreciation, energy consumption and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide and to consider them in the wider framework of the cost effectiveness of the strategies for the early diagnosis of prostatic cancer. The overall cost of TRUSB was Itl. 249,000, obtained by adding together the costs of: personnel (Itl. 160,000); materials (Itl. 59,000); equipment maintenance and depreciation (Itl. 12,400); energy consumption (Itl. 100); hospital overheads (Itl. 17,500). The literature review points out TRUSB as a clinically invasive tool for diagnosing prostatic carcinoma whose cost-effectiveness is debated. Cadaver studies report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, are very likely to be positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the positivity of exploration and/or transrectal ultrasound findings. Despite the strict application of all these criteria and the critical assessment of the patient's general conditions, TRUSB is indicated for 16% of the male population over 50, with obvious implications. It has been recently

  7. WE-FG-BRA-07: Theranostic Nanoparticles Improve Clinical MR-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Detappe, A [Dana-Farber Cancer Institute, Boston, MA (United States); Institut Lumiere-Matiere, Lyon, FR (France); Kunjachan, S; Berbeco, R [Dana-Farber Cancer Institute, Boston, MA (United States); Sancey, L; Motto-Ros, V; Tillement, O [Institut Lumiere-Matiere, Lyon, FR (France)

    2016-06-15

    Purpose: MR-guided radiation therapy is a current and emerging clinical reality. We have designed and tested a silica-based gadolinium chelates nanoparticle (AGuIX) for integration with MR-guided radiation therapy. The AGuIX nanoparticles used in this study are a dual-modality probe with radiosensitization properties and better MRI contrast than current FDA-approved gadolinium chelates. In advance of an approved Phase I clinical trial, we report on the efficacy and safety in multiple animal models and clinically relevant radiation conditions. By modeling our study on current clinic workflows, we show compatibility with modern patient care, thus heightening the translational significance of this research. Methods: The dual imaging and therapy functionality of AGuIX was investigated in mice with clinical radiation beams while safety was evaluated in mice, and nonhuman primates after systemic injection of 0.25 mg/g of nanoparticles. MRI/ICP-MS were used to measure tumor uptake and biodistribution. Due to their small size (2–3 nm), AGuIX have good renal clearance (t1/2=19min). We performed in vitro cell uptake quantification and radiosensitization studies (clonogenic assays and DNA damage quantification). In vivo radiation therapy studies were performed with both 6MV and 6MV-FFF clinical radiation beams. Histology was performed to measure the increase in DNA damage in the tumor and to evaluate the toxicity in healthy tissues. Results: In vitro and in vivo results demonstrate statistically significant increase (P < 0.01) in DNA damage, tumor growth supression and survival (+100 days) compared to radiation alone. Negligible toxicity was observed in all of the animal models. The combination of 6MV-FFF/AGuIX demonstrated a substantial dose enhancement compared to 6MV/AGuIX (DEF = 1.36 vs. 1.22) due to the higher proportion of low energy photons. Conclusion: With demonstrated efficacy and negligible toxicity in mice and non-human primates, AGuIX is a biocompatible

  8. WE-FG-BRA-07: Theranostic Nanoparticles Improve Clinical MR-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Detappe, A; Kunjachan, S; Berbeco, R; Sancey, L; Motto-Ros, V; Tillement, O

    2016-01-01

    Purpose: MR-guided radiation therapy is a current and emerging clinical reality. We have designed and tested a silica-based gadolinium chelates nanoparticle (AGuIX) for integration with MR-guided radiation therapy. The AGuIX nanoparticles used in this study are a dual-modality probe with radiosensitization properties and better MRI contrast than current FDA-approved gadolinium chelates. In advance of an approved Phase I clinical trial, we report on the efficacy and safety in multiple animal models and clinically relevant radiation conditions. By modeling our study on current clinic workflows, we show compatibility with modern patient care, thus heightening the translational significance of this research. Methods: The dual imaging and therapy functionality of AGuIX was investigated in mice with clinical radiation beams while safety was evaluated in mice, and nonhuman primates after systemic injection of 0.25 mg/g of nanoparticles. MRI/ICP-MS were used to measure tumor uptake and biodistribution. Due to their small size (2–3 nm), AGuIX have good renal clearance (t1/2=19min). We performed in vitro cell uptake quantification and radiosensitization studies (clonogenic assays and DNA damage quantification). In vivo radiation therapy studies were performed with both 6MV and 6MV-FFF clinical radiation beams. Histology was performed to measure the increase in DNA damage in the tumor and to evaluate the toxicity in healthy tissues. Results: In vitro and in vivo results demonstrate statistically significant increase (P < 0.01) in DNA damage, tumor growth supression and survival (+100 days) compared to radiation alone. Negligible toxicity was observed in all of the animal models. The combination of 6MV-FFF/AGuIX demonstrated a substantial dose enhancement compared to 6MV/AGuIX (DEF = 1.36 vs. 1.22) due to the higher proportion of low energy photons. Conclusion: With demonstrated efficacy and negligible toxicity in mice and non-human primates, AGuIX is a biocompatible

  9. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  10. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    International Nuclear Information System (INIS)

    Baek, Song Ee; Oh, Young Taik; Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul

    2010-01-01

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4±1.78: group 2, 2.8±1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  11. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  12. Usefulness of transrectal ultrasound-guided 12 core biopsy method in patients with clinically suspected prostate cancer

    International Nuclear Information System (INIS)

    Kwon, Se Hwan; Lim, Joo Won; Park, Seong Jin; Ko, Young Tae; Kim, Yoon Wha

    2000-01-01

    To evaluate the improvement of prostate cancer detection provided by transrectal ultrasound (TRUS)-guided 12 core biopsy method compared with sextant biopsy method. Between June 1997 and February 1999, 29 patients with pathologically proven prostate cancer in 124 patients who underwent TRUS-guided 12 core biopsy method were evaluated. They had abnormal findings in prostate specific antigen (PSA), digital rectal examination (DRE) or TRUS findings. The prostate was diffusely enlarged in all patients on DRE findings and in 15 cases (15/29, 52%), hard nodule was palpated. The average of PSA and prostate specific antigen density (PSAD) is 229.33 ng/ml (1-2280) and 9.14 ng/ml/cm 3 (0.048-142.5), respectively, 12 transrectal biopsy, including 2 transition zones, was performed in both lobe, 6 biopsies were located in both base, middle and apex. Then 2 biopsies were inserted between 3 biopsies in both peripheral zone and 2 biopsies were performed in both transition zone. Each specimen was pathologically examined. The results of pathology were compared with method 1 and 2, respectively. We defined the method 1 and 2 as different sextant biopsy method. The method 1 is that cores are taken from both base, middle and apex and method 2 is that cores are taken from both base, apex and transition zone. TRUS findings were analyzed by two radiologists. Of the 29 patients with prostate cancer, 3 (10%) had carcinomas only in the additional regions as compared with method. When compared with method 2,2 (7.0%) had carcinomas only in the additional regions. 2 patients were same in both cases. TRUS findings were abnormal in 21 cases in all patients whose 12 biopsy method was not helpful. 12 biopsy method was helpful in 2/8 (25%) whose TRUS findings were non-specific and 1/21 (4.8%) whose TRUS findings were abnormal. Small low echoic lesion was seen in one patients whose 12 biopsy method was helpful, but cancer was found in other area. TRUS-guided 12 core biopsy method may be superior to

  13. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion

    NARCIS (Netherlands)

    Venderink, W.; Govers, T.M.; Rooij, M. de; Futterer, J.J.; Sedelaar, J.P.M.

    2017-01-01

    OBJECTIVE: Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. MATERIALS AND METHODS: A decision tree and Markov model were

  14. A meta-analysis of use of Prostate Imaging Reporting and Data System Version 2 (PI-RADS V2) with multiparametric MR imaging for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Li; Chen, Sipan [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an, Shaanxi (China); Shaanxi Provincial People' s Hospital, Department of MRI, Xi' an, Shaanxi (China); Tang, Min; Lei, Xiaoyan; Zhang, Xiaoling [Shaanxi Provincial People' s Hospital, Department of MRI, Xi' an, Shaanxi (China); Huan, Yi [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an, Shaanxi (China)

    2017-12-15

    This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 x 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. (orig.)

  15. Evaluation of proton MR spectroscopy at 3 Tesla without endorectal coil in patients with a localized prostate cancer treated with exclusive radiotherapy

    International Nuclear Information System (INIS)

    Crehange, G.

    2011-01-01

    Prostate cancer is the most frequent tumour affecting the male population. When the prostate is not removed and is treated with radiation therapy, PSA slowly decreases over time to reach its nadir, even sometimes 18 to 24 months after the completion of radiation therapy without combined androgen suppression therapy. When combined with hormones, PSA falls abruptly with no possibility to perceive the impact of either hormones or radiation effects on PSA.The optimal value of PSA that should be reached after radiation therapy (nadir) and time to this nadir are still unclear.Even when a satisfactory value of the PSA nadir is reached, on-going variations of the PSA and its 'bounce' effects, which occurs in 20% to 40% of the cases.Proton magnetic resonance spectroscopy allows one to assess the relative concentration of Choline and Citrate. Choline is a metabolite of whose concentration is often increased in the presence of a tumour, whereas the synthesis and the oxidation of Citrate are two decisive elements of the normal metabolism, functional abilities, growth, reproduction and survival of prostatic cells. This MR technique can be performed in combination with diffusion-weighted MRI and DCE-MRI (multi-parametric MRI).The goal of our study was to evaluate the feasibility of a 3D CSI proton MR spectroscopy of the entire prostate gland at 3.0 Tesla without an endorectal coil among patients with a localised prostate cancer treated with radiation therapy, with or without hormones. We first have classified spectra in a 5-point scale (from benign: class I, to malign: class V) based on a control group with radical prostatectomy as the standard of reference. This classification enabled us to establish a strong correlation between malignant spectra or the metabolic tumor volume and clinically validated prognostic factors.In parallel, a prospective clinical trial of which the aim is to Evaluate the Response to Irradiation with proton MR Spectroscopy (ERIS trial) has been set up to

  16. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  17. Nonspecific Presentation of a Multiloculated Prostatic Abscess After Transurethral Prostatic Biopsy for Elevated Prostate-specific Antigen Level

    OpenAIRE

    Gandhi, Nilay M.; Lin, Joseph; Schaeffer, Edward

    2014-01-01

    Prostate postbiopsy infectious complications typically present in the form of prostatitis and uncommonly urosepsis. Prostatic abscesses are generally found after multiple bouts of prostatitis and are associated with a clinically septic picture requiring intensive care unit admission and resuscitation. We report the case of a 65-year-old man who presented with prostatic abscess in the setting of nonspecific urinary symptoms after transrectal ultrasonography–guided prostate biopsy. At 4-month f...

  18. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  19. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3

  20. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    International Nuclear Information System (INIS)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R

    2015-01-01

    Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3

  1. Effect of a Low-Intensity PSA-Based Screening Intervention on Prostate Cancer Mortality: The CAP Randomized Clinical Trial.

    Science.gov (United States)

    Martin, Richard M; Donovan, Jenny L; Turner, Emma L; Metcalfe, Chris; Young, Grace J; Walsh, Eleanor I; Lane, J Athene; Noble, Sian; Oliver, Steven E; Evans, Simon; Sterne, Jonathan A C; Holding, Peter; Ben-Shlomo, Yoav; Brindle, Peter; Williams, Naomi J; Hill, Elizabeth M; Ng, Siaw Yein; Toole, Jessica; Tazewell, Marta K; Hughes, Laura J; Davies, Charlotte F; Thorn, Joanna C; Down, Elizabeth; Davey Smith, George; Neal, David E; Hamdy, Freddie C

    2018-03-06

    Prostate cancer screening remains controversial because potential mortality or quality-of-life benefits may be outweighed by harms from overdetection and overtreatment. To evaluate the effect of a single prostate-specific antigen (PSA) screening intervention and standardized diagnostic pathway on prostate cancer-specific mortality. The Cluster Randomized Trial of PSA Testing for Prostate Cancer (CAP) included 419 582 men aged 50 to 69 years and was conducted at 573 primary care practices across the United Kingdom. Randomization and recruitment of the practices occurred between 2001 and 2009; patient follow-up ended on March 31, 2016. An invitation to attend a PSA testing clinic and receive a single PSA test vs standard (unscreened) practice. Primary outcome: prostate cancer-specific mortality at a median follow-up of 10 years. Prespecified secondary outcomes: diagnostic cancer stage and Gleason grade (range, 2-10; higher scores indicate a poorer prognosis) of prostate cancers identified, all-cause mortality, and an instrumental variable analysis estimating the causal effect of attending the PSA screening clinic. Among 415 357 randomized men (mean [SD] age, 59.0 [5.6] years), 189 386 in the intervention group and 219 439 in the control group were included in the analysis (n = 408 825; 98%). In the intervention group, 75 707 (40%) attended the PSA testing clinic and 67 313 (36%) underwent PSA testing. Of 64 436 with a valid PSA test result, 6857 (11%) had a PSA level between 3 ng/mL and 19.9 ng/mL, of whom 5850 (85%) had a prostate biopsy. After a median follow-up of 10 years, 549 (0.30 per 1000 person-years) died of prostate cancer in the intervention group vs 647 (0.31 per 1000 person-years) in the control group (rate difference, -0.013 per 1000 person-years [95% CI, -0.047 to 0.022]; rate ratio [RR], 0.96 [95% CI, 0.85 to 1.08]; P = .50). The number diagnosed with prostate cancer was higher in the intervention group (n = 8054; 4

  2. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  3. The Role of Seminal Vesicle Motion in Target Margin Assessment for Online Image-Guided Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Liang Jian; Wu Qiuwen; Yan Di

    2009-01-01

    Purpose: For patients with intermediate- and high-risk prostate cancer, the seminal vesicles (SVs) are included in the clinical target volume (CTV). The purposes of this study are to investigate interfraction motion characteristics of the SVs and determine proper margins for online computed tomography image guidance. Methods and Materials: Twenty-four patients, each with 16 daily helical computed tomography scans, were included in this study. A binary image mask was used for image registration to determine daily organ motion. Two online image-guided radiotherapy strategies (prostate only and prostate + SVs) were simulated in a hypofractionated scheme. Three margin designs were studied for both three-dimensional conformal radiotherapy and intensity-modulated radiotherapy (IMRT). In prostate-only guidance, Margin A was uniformly applied to the whole CTV, and Margin B was applied to the SVs with a fixed 3-mm prostate margin. In prostate plus SV guidance, Margin C was uniformly applied to the CTV. The minimum margins were sought to satisfy the criterion that minimum cumulative CTV dose be more than those of the planning target volume in the plan for greater than 95% of patients. Results: The prostate and SVs move significantly more in the anterior-posterior and superior-inferior than right-left directions. The anterior-posterior motion of the prostate and SVs correlated (R 2 = 0.7). The SVs move significantly more than the prostate. The minimum margins found were 2.5 mm for three-dimensional conformal radiotherapy and 4.5, 4.5, and 3.0 mm for Margins A, B, and C for IMRT, respectively. Margins for IMRT were larger, but the irradiated volume and doses to critical structures were smaller. Minimum margins of 4.5 mm to the SVs and 3 mm to the prostate are recommended for IMRT with prostate-only guidance. Conclusions: The SVs move independently from the prostate gland, and additional margins are necessary for image-guided radiotherapy

  4. Role of image-guided patient repositioning and online planning in localized prostate cancer IMRT

    International Nuclear Information System (INIS)

    Lerma, Fritz A.; Liu, Bei; Wang, Zhendong; Yi, Byongyong; Amin, Pradip; Liu, Sandy; Feng Yuanming; Yu, Cedric X.

    2009-01-01

    Purpose: To determine the expected benefit of image-guided online replanning over image-guided repositioning of localized prostate cancer intensity-modulated radiotherapy (IMRT). Materials and methods: On 10 to 11 CT scans of each of 10 early-stage prostate cancer patients, the prostate, bladder and rectum are manually segmented. Using a 3-mm PTV margin expansion from the CTV, an IMRT plan is made on the first CT scan of each patient. Online repositioning is simulated by recalculating the IMRT plan from the initial CT scan on the subsequent CT scans of each patient. For online replanning, IMRT is replanned twice on all CT scans, using 0-mm and 3-mm margins. The doses from subsequent CT images of each patient are then deformed to the initial CT anatomy using a mesh-based thin-plate B-spline deformation method and are accumulated for DVH and isodose review. Results: Paired t-tests show that online replanning with 3-mm margins significantly increases the prostate volume receiving the prescribed dose over replanning with 0-mm margins (p-value 0.004); gives marginally better target coverage than repositioning with 3-mm margins(p-value 0.06-0.343), and reduces variations in target coverage over repositioning. Fractional volumes of rectum and bladder receiving 75%, 80%, 85%, 90%, and 95% (V75, V80, V85, V90, and V95) of the prescription dose are evaluated. V90 and V95 values for the rectum are 1.6% and 0.7 % for 3-mm margin replanning and 1% and 0.4 % for 0-mm margin replanning, with p-values of 0.010-0.011. No significant differences between repositioning and replanning with 3-mm margins are found for both the rectum and the bladder. Conclusions: Image-guided replanning using 3-mm margins reduces target coverage variations, and maintains comparable rectum and bladder sparing to patient repositioning in localized prostate cancer IMRT. Marginal reductions in doses to rectum and bladder are possible when planning margins are eliminated in the online replanning scenario

  5. Multiparametric magnetic resonance imaging of the prostate: current concepts.

    NARCIS (Netherlands)

    Bittencourt, L.K.; Hausmann, D.; Sabaneeff, N.; Gasparetto, E.L.; Barentsz, J.O.

    2014-01-01

    Multiparametric MR (mpMR) imaging is rapidly evolving into the mainstay in prostate cancer (PCa) imaging. Generally, the examination consists of T2-weighted sequences, diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) evaluation, and less often proton MR spectroscopy imaging (MRSI).

  6. Diet and dietary supplement intervention trials for the prevention of prostate cancer recurrence: a review of the randomized controlled trial evidence.

    Science.gov (United States)

    Van Patten, Cheri L; de Boer, Johan G; Tomlinson Guns, Emma S

    2008-12-01

    We review the effect of diet and dietary supplement interventions on prostate cancer progression, recurrence and survival. A literature search was conducted in MEDLINE, EMBASE and CINAHL to identify diet and dietary supplement intervention studies in men with prostate cancer using prostate specific antigen or prostate specific antigen doubling time as a surrogate serum biomarker of prostate cancer recurrence and/or survival. Of the 32 studies identified 9 (28%) were randomized controlled trials and the focus of this review. In these studies men had confirmed prostate cancer and elevated or increasing prostate specific antigen. Only 1 trial included men with metastatic disease. When body mass index was reported, men were overweight or obese. A significant decrease in prostate specific antigen was observed in some studies using a low fat vegan diet, soy beverage or lycopene supplement. While not often reported as an end point, a significant increase in prostate specific antigen doubling time was observed in a study on lycopene supplementation. In only 1 randomized controlled trial in men undergoing orchiectomy was a survival end point of fewer deaths with lycopene supplementation reported. A limited number of randomized controlled trials were identified in which diet and dietary supplement interventions appeared to slow disease progression in men with prostate cancer, although results vary. Studies were limited by reliance on the surrogate biomarker prostate specific antigen, sample size and study duration. Well designed trials are warranted to expand knowledge, replicate findings and further assess the impact of diet and dietary supplement interventions on recurrence and treatment associated morbidities.

  7. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy

    NARCIS (Netherlands)

    Smitsmans, Monique H. P.; de Bois, Josien; Sonke, Jan-Jakob; Betgen, Anja; Zijp, Lambert J.; Jaffray, David A.; Lebesque, Joos V.; van Herk, Marcel

    2005-01-01

    PURPOSE: Previously, we developed an automatic three-dimensional gray-value registration (GR) method for fast prostate localization that could be used during online or offline image-guided radiotherapy. The method was tested on conventional computed tomography (CT) scans. In this study, the

  8. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  9. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  10. The clinical utility of multimodal MR image-guided needle biopsy in cerebral gliomas.

    Science.gov (United States)

    Yao, Chengjun; Lv, Shunzeng; Chen, Hong; Tang, Weijun; Guo, Jun; Zhuang, Dongxiao; Chrisochoides, Nikos; Wu, Jinsong; Mao, Ying; Zhou, Liangfu

    2016-01-01

    Our aim was to evaluate the diagnostic value of multimodal Magnetic Resonance (MR) Image in the stereotactic biopsy of cerebral gliomas, and investigate its implications. Twenty-four patients with cerebral gliomas underwent (1)H Magnetic Resonance Spectroscopy ((1)H-MRS)- and intraoperative Magnetic Resonance Imaging (iMRI)-supported stereotactic biopsy, and 23 patients underwent only the preoperative MRI-guided biopsy. The diagnostic yield, morbidity and mortality rates were analyzed. In addition, 20 patients underwent subsequent tumor resection, thus the diagnostic accuracy of the biopsy was further evaluated. The diagnostic accuracies of biopsies evaluated by tumor resection in the trial groups were better than control groups (92.3% and 42.9%, respectively, p = 0.031). The diagnostic yield in the trial groups was better than the control groups, but the difference was not statistically significant (100% and 82.6%, respectively, p = 0.05). The morbidity and mortality rates were similar in both groups. Multimodal MR image-guided glioma biopsy is practical and valuable. This technique can increase the diagnostic accuracy in the stereotactic biopsy of cerebral gliomas. Besides, it is likely to increase the diagnostic yield but requires further validation.

  11. MR imaging-guided cryoablation of metastatic brain tumours: initial experience in six patients

    International Nuclear Information System (INIS)

    Li, Chengli; Wu, Lebin; Song, Jiqing; Liu, Ming; Lv, Yubo; Sequeiros, Roberto Blanco

    2010-01-01

    The objective was to evaluate the initial experience and safety of magnetic resonance imaging (MRI)-guided transcranial cryoablation in cystic metastatic brain tumours. Seven cystic metastatic brain tumours in six patients were treated with cryoablation. The approval from the local ethics committee and individual patient consent were acquired before the study. Before the procedure the tumours were detected with conventional CT or MRI. The procedure was performed under local anaesthesia and conscious sedation. A 0.23-T open MRI system with optical tracking was used for procedural planning, instrument guidance and procedural monitoring of the ice ball formation. An MR-compatible, argon-based cryoablation system was used. The schedule of follow-up imaging ranged from 12 days to 12 months. Seven treatment sessions were performed. All the cryoprobes were successfully inserted into the target with one pass. All the patients tolerated the procedure well without experiencing any neurological deficits during the treatment phase or during the immediate post-treatment period. One patient died 12 days after cryoablation. MR-guided and monitored metastasis brain tumour cryoablation is technically feasible and may represent an alternative treatment in selected patients. (orig.)

  12. Value of prostate specific antigen and prostatic volume ratio (PSA/V) as the selection criterion for US-guided prostatic biopsy. Importanza del rapporto tra antigene prostatico specifico e volume prostatico nella selezione dei pazienti da sottoporre a biopsia ecoguidata della prostata

    Energy Technology Data Exchange (ETDEWEB)

    Veneziano, S; Paulica, P; Querze' , R; Viglietta, G; Trenta, A [Ospedale Melpighi, Bologna (Italy). Serv. di Radiologia

    1991-01-01

    US-guided biopsy was performed in 94 patients with suspected lesions at transerectal US. Histology demonstrated carcinoma in 43 cases, benign hyperplasia in 44, and prostatis in 7. In all cases the prostate specific antigen (PSA) was calculated, by means of US, together with prostatic volume (v). PSA was related to the corresponding gland volume, which resulted in PSA/V ratio. Our study showed PSA/V ration to have higher sensitivity and specificity than absolulute PSA value in the diagnosis of prostatic carcinoma. The authors believe prostate US-guided biopsy to be: a) necessary when the suspected area has PSA/V ratio >0.15, and especially when PSA/V >0.30; b) not indicated when echo-structural alterations are associated with PSA/V <0.15, because they are most frequently due to benign lesions. The combined use of PSA/V ratio and US is therefore suggested to select the patients in whom biopsy is to be performed. 20 refs.

  13. Reference Dose Rates for Fluoroscopy Guided Interventions

    International Nuclear Information System (INIS)

    Geleijns, J.; Broerse, J.J.; Hummel, W.A.; Schalij, M.J.; Schultze Kool, L.J.; Teeuwisse, W.; Zoetelief, J.

    1998-01-01

    The wide diversity of fluoroscopy guided interventions which have become available in recent years has improved patient care. They are being performed in increasing numbers, particularly at departments of cardiology and radiology. Some procedures are very complex and require extended fluoroscopy times, i.e. longer than 30 min, and radiation exposure of patient and medical staff is in some cases rather high. The occurrence of radiation-induced skin injuries on patients has shown that radiation protection for fluoroscopy guided interventions should not only be focused on stochastic effects, i.e. tumour induction and hereditary risks, but also on potential deterministic effects. Reference dose levels are introduced by the Council of the European Communities as an instrument to achieve optimisation of radiation protection in radiology. Reference levels in conventional diagnostic radiology are usually expressed as entrance skin dose or dose-area product. It is not possible to define a standard procedure for complex interventions due to the large inter-patient variations with regard to the complexity of specific interventional procedures. Consequently, it is not realistic to establish a reference skin dose or dose-area product for complex fluoroscopy guided interventions. As an alternative, reference values for fluoroscopy guided interventions can be expressed as the entrance dose rates on a homogeneous phantom and on the image intensifier. A protocol has been developed and applied during a nationwide survey of fluoroscopic dose rate during catheter ablations. From this survey reference entrance dose rates of respectively 30 mGy.min -1 on a polymethylmethacrylate (PMMA) phantom with a thickness of 21 cm, and of 0.8 μGy.s -1 on the image intensifier have been derived. (author)

  14. Prostate Cancer Foundation News

    Science.gov (United States)

    ... Finding a Doctor Treatment Options Side Effects Managing Prostate Cancer Treatment Related Side Effects Clinical Trials Patient Resources Guides Videos Prostate Cancer FAQs Information by Stage Newly Diagnosed with Prostate ...

  15. Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rempp, Hansjoerg, E-mail: hansjoerg.rempp@med.uni-tuebingen.de; Clasen, Stephan [Eberhard Karls University of Tuebingen, Department of Diagnostic and Interventional Radiology (Germany); Pereira, Philippe L. [SLK-Kliniken, Clinic for Radiology, Nuclear Medicine, and Minimal Invasive Therapies (Germany)

    2012-12-15

    Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

  16. Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

    International Nuclear Information System (INIS)

    Rempp, Hansjörg; Clasen, Stephan; Pereira, Philippe L.

    2012-01-01

    Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

  17. (31) P MR spectroscopic imaging combined with (1) H MR spectroscopic imaging in the human prostate using a double tuned endorectal coil at 7T.

    Science.gov (United States)

    Luttje, Mariska P; Italiaander, Michel G M; Arteaga de Castro, Catalina S; van der Kemp, Wybe J M; Luijten, Peter R; van Vulpen, Marco; van der Heide, Uulke A; Klomp, Dennis W J

    2014-12-01

    Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer. A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancer patients. The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate. (1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel. © 2013 Wiley Periodicals, Inc.

  18. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  19. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  20. Imaging and intervention in prostate cancer: Current perspectives and future trends

    Directory of Open Access Journals (Sweden)

    Sanjay Sharma

    2014-01-01

    Full Text Available Prostate cancer is the commonest malignancy in men that causes significant morbidity and mortality worldwide. Screening by digital rectal examination (DRE and serum prostate-specific antigen (PSA is used despite its limitations. Gray-scale transrectal ultrasound (TRUS, used to guide multiple random prostatic biopsies, misses up to 20% cancers and frequently underestimates the grade of malignancy. Increasing the number of biopsy cores marginally increases the yield. Evolving techniques of real-time ultrasound elastography (RTE and contrast-enhanced ultrasound (CEUS are being investigated to better detect and improve the yield by allowing "targeted" biopsies. Last decade has witnessed rapid developments in magnetic resonance imaging (MRI for improved management of prostate cancer. In addition to the anatomical information, it is capable of providing functional information through diffusion-weighted imaging (DWI, magnetic resonance spectroscopy (MRS, and dynamic contrast-enhanced (DCE MRI. Multi-parametric MRI has the potential to exclude a significant cancer in majority of cases. Inclusion of MRI before prostatic biopsy can reduce the invasiveness of the procedure by limiting the number of cores needed to make a diagnosis and support watchful waiting in others. It is made possible by targeted biopsies as opposed to random. With the availability of minimally invasive therapeutic modalities like high-intensity focused ultrasound (HIFU and interstitial laser therapy, detecting early cancer is even more relevant today. [18F]--fluorodeoxyglucose positron emission tomography/computed tomography ( 18 FDG PET/CT has no role in the initial evaluation of prostate cancer. Choline PET has been recently found to be more useful. Fluoride-PET has a higher sensitivity and resolution than a conventional radionuclide bone scan in detecting skeletal metastases.

  1. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  2. Linked statistical shape models for multi-modal segmentation: application to prostate CT-MR segmentation in radiotherapy planning

    Science.gov (United States)

    Chowdhury, Najeeb; Chappelow, Jonathan; Toth, Robert; Kim, Sung; Hahn, Stephen; Vapiwala, Neha; Lin, Haibo; Both, Stefan; Madabhushi, Anant

    2011-03-01

    We present a novel framework for building a linked statistical shape model (LSSM), a statistical shape model (SSM) that links the shape variation of a structure of interest (SOI) across multiple imaging modalities. This framework is particularly relevant in scenarios where accurate delineations of a SOI's boundary on one of the modalities may not be readily available, or difficult to obtain, for training a SSM. We apply the LSSM in the context of multi-modal prostate segmentation for radiotherapy planning, where we segment the prostate on MRI and CT simultaneously. Prostate capsule segmentation is a critical step in prostate radiotherapy planning, where dose plans have to be formulated on CT. Since accurate delineations of the prostate boundary are very difficult to obtain on CT, pre-treatment MRI is now beginning to be acquired at several medical centers. Delineation of the prostate on MRI is acknowledged as being significantly simpler to do compared to CT. Hence, our framework incorporates multi-modal registration of MRI and CT to map 2D boundary delineations of prostate (obtained from an expert radiation oncologist) on MR training images onto corresponding CT images. The delineations of the prostate capsule on MRI and CT allows for 3D reconstruction of the prostate shape which facilitates the building of the LSSM. We acquired 7 MRI-CT patient studies and used the leave-one-out strategy to train and evaluate our LSSM (fLSSM), built using expert ground truth delineations on MRI and MRI-CT fusion derived capsule delineations on CT. A unique attribute of our fLSSM is that it does not require expert delineations of the capsule on CT. In order to perform prostate MRI segmentation using the fLSSM, we employed a regionbased approach where we deformed the evolving prostate boundary to optimize a mutual information based cost criterion, which took into account region-based intensity statistics of the image being segmented. The final prostate segmentation was then

  3. Three-dimensional computed tomography-guided monotherapeutic pararectal brachytherapy of prostate cancer with seminal vesicle invasion

    International Nuclear Information System (INIS)

    Koutrouvelis, Panos; Lailas, Niko; Hendricks, Fred; Gil-Montero, Guillermo; Sehn, James; Katz, Stuart

    2001-01-01

    Purpose: To treat patients with prostate cancer and seminal vesicle invasion with monotherapeutic three dimensional computed tomography (3-DCT)-guided posterior pararectal brachytherapy. Methods and materials: Three hundred and sixty two patients with clinical stage T1 a,b or T2 a,b of prostate cancer were referred for 3-DCT-guided brachytherapy. Each underwent further staging with 3-D CT-guided pararectal biopsy of the seminal vesicles under local anesthesia during the pre-treatment CT-planning. Forty-three patients (12%) were upstaged to T3 cNoMo disease. In the set of 43 patients, Eight had Gleason's score≤6, 24 Gleason's score=7, and 11 patients ≥8. Initial PSA was 20 in 18 patients. Of the 43 patients, 37 patients were treated monotherapeutically with 3-D CT-guided brachytherapy. No patients received hormone therapy after the implant. The prescribed dosage to the seminal vesicles and prostate is 120 Gy with Pd-103 seeds and 144 Gy with 1-125 seeds. Results: The prescribed dosage was achieved in all 37 patient's throughout the seminal vesicles whose range of target radiation extended 5-10 mm outside the target in the adjacent fat as calculated with post-implant CT-dosimetry with Varian Brachy Vision or MMS software. Prostate Specific Antigen (PSA) outcome data were available in 34 patients treated with monotherapy and follow up ranged from 12-56 months (median, 24 months). Decreased PSA levels were stratified into six groups based on the presenting Gleason's score and initial PSA. In the first group (with Gleason's score≤6 and initial PSA 20 ng/ml), PSA decreased to less than 0.5 ng/ml in four out of eight patients (50%). All of the patients in the fourth group (with Gleason's score≥8 and initial PSA 20 ng/ml). There were no patients with Gleason's score of 1-6 and greater than 20 ng/ml initial PSA. Patients, irrespective of the Gleason's score and PSA, had an overall response of decreased PSA (less than 1 ng/ml) of 79%. Conclusion: 3-D CT-guided

  4. Real-time MRI guidance of cardiac interventions.

    Science.gov (United States)

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J

  5. A biopsychosocial approach to sexual recovery after prostate cancer surgery: the role of grief and mourning.

    Science.gov (United States)

    Wittmann, Daniela; Foley, Sallie; Balon, Richard

    2011-01-01

    Erectile dysfunction is a common side-effect of prostate cancer surgery that causes men suffering and hinders their sexual recovery. There are studies that describe men's and partners' distress and couples' difficulties engaging in sexual recovery. A few studies show a short-term benefit of brief psycho-social interventions such as psychoeducation and counseling. However, there is no conceptual framework to guide psychosocial treatments. We propose a model of intervention in sexual recovery that incorporates grief and mourning as a gateway to new and satisfying sexuality after prostate cancer treatment.

  6. Non-invasive estimation of prostate cancer aggressiveness using diffusion-weighted MRI and 3D proton MR spectroscopy at 3.0 T.

    Science.gov (United States)

    Thörmer, Gregor; Otto, Josephin; Horn, Lars-Christian; Garnov, Nikita; Do, Minh; Franz, Toni; Stolzenburg, Jens-Uwe; Moche, Michael; Kahn, Thomas; Busse, Harald

    2015-01-01

    Clinical management of prostate cancer increasingly aims to distinguish aggressive types that require immediate and radical treatment from indolent tumors that are candidates for watchful waiting. This requires reliable and reproducible parameters to effectively control potential cancer progression. Magnetic resonance imaging (MRI) may provide a non-invasive means for this purpose. To assess the value of diffusion-weighted imaging and proton MR spectroscopy for the prediction of prostate cancer (PCa) aggressiveness. In 39 of 64 consecutive patients who underwent endorectal 3-T MRI prior to radical prostatectomy, prostate specimens were analyzed as whole-mount step sections. Apparent diffusion coefficient (ADC), normalized ADC (nADC: tumor/healthy tissue), choline/citrate (CC), and (choline + creatine)/citrate (CCC) ratios were correlated with Gleason scores (GS) from histopathological results. The power to discriminate low (GS ≤ 6) from higher-risk (GS ≥ 7) tumors was assessed with receiver operating characteristics (area under the curve [AUC]). Resulting threshold values were used by a blinded reader to distinguish between aggressive and indolent tumors. Ninety lesions (1 × GS = 5, 41 × GS = 6, 36 × GS = 7, 12 × GS = 8) were considered. nADC (AUC = 0.90) showed a higher discriminatory power than ADC (AUC = 0.79). AUC for CC and CCC were 0.73 and 0.82, respectively. Using either nADC  1.3, as well as both criteria for aggressive PCa, the reader correctly identified aggressive and indolent tumors in 31 (79%), 28 (72%), and 33 of 39 patients (85%), respectively. Predictions of tumor aggressiveness from TRUS-guided biopsies were correct in 27 of 36 patients (75%). The combination of a highly sensitive normalized ADC with a highly specific CCC was found to be well suited to prospectively estimate PCa aggressiveness with a similar diagnostic accuracy as biopsy results. © The Foundation Acta Radiologica

  7. Full automatic fiducial marker detection on coil arrays for accurate instrumentation placement during MRI guided breast interventions

    Science.gov (United States)

    Filippatos, Konstantinos; Boehler, Tobias; Geisler, Benjamin; Zachmann, Harald; Twellmann, Thorsten

    2010-02-01

    With its high sensitivity, dynamic contrast-enhanced MR imaging (DCE-MRI) of the breast is today one of the first-line tools for early detection and diagnosis of breast cancer, particularly in the dense breast of young women. However, many relevant findings are very small or occult on targeted ultrasound images or mammography, so that MRI guided biopsy is the only option for a precise histological work-up [1]. State-of-the-art software tools for computer-aided diagnosis of breast cancer in DCE-MRI data offer also means for image-based planning of biopsy interventions. One step in the MRI guided biopsy workflow is the alignment of the patient position with the preoperative MR images. In these images, the location and orientation of the coil localization unit can be inferred from a number of fiducial markers, which for this purpose have to be manually or semi-automatically detected by the user. In this study, we propose a method for precise, full-automatic localization of fiducial markers, on which basis a virtual localization unit can be subsequently placed in the image volume for the purpose of determining the parameters for needle navigation. The method is based on adaptive thresholding for separating breast tissue from background followed by rigid registration of marker templates. In an evaluation of 25 clinical cases comprising 4 different commercial coil array models and 3 different MR imaging protocols, the method yielded a sensitivity of 0.96 at a false positive rate of 0.44 markers per case. The mean distance deviation between detected fiducial centers and ground truth information that was appointed from a radiologist was 0.94mm.

  8. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

    International Nuclear Information System (INIS)

    Niebuhr, Nina I.; Johnen, Wibke; Güldaglar, Timur; Runz, Armin; Echner, Gernot; Mann, Philipp; Möhler, Christian; Pfaffenberger, Asja; Greilich, Steffen; Jäkel, Oliver

    2016-01-01

    Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K_2HPO_4, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy

  9. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Niebuhr, Nina I., E-mail: n.niebuhr@dkfz.de; Johnen, Wibke; Güldaglar, Timur; Runz, Armin; Echner, Gernot; Mann, Philipp; Möhler, Christian; Pfaffenberger, Asja; Greilich, Steffen [Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany and Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology, Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Jäkel, Oliver [Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology, Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Department of Medical Physics, Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, Heidelberg 69120 (Germany)

    2016-02-15

    Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K{sub 2}HPO{sub 4}, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy.

  10. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    Science.gov (United States)

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is used to guide the biopsy to specific regions of the prostate gland. When the examination is ... is relatively insensitive to the pain in the region of the prostate. A biopsy will add time ...

  12. MR-guided stereotactic neurosurgery-comparison of fiducial-based and anatomical landmark transformation approaches

    International Nuclear Information System (INIS)

    Hunsche, S; Sauner, D; Maarouf, M; Hoevels, M; Luyken, K; Schulte, O; Lackner, K; Sturm, V; Treuer, H

    2004-01-01

    For application in magnetic resonance (MR) guided stereotactic neurosurgery, two methods for transformation of MR-image coordinates in stereotactic, frame-based coordinates exist: the direct stereotactic fiducial-based transformation method and the indirect anatomical landmark method. In contrast to direct stereotactic MR transformation, indirect transformation is based on anatomical landmark coregistration of stereotactic computerized tomography and non-stereotactic MR images. In a patient study, both transformation methods have been investigated with visual inspection and mutual information analysis. Comparison was done for our standard imaging protocol, including t2-weighted spin-echo as well as contrast enhanced t1-weighted gradient-echo imaging. For t2-weighted spin-echo imaging, both methods showed almost similar and satisfying performance with a small, but significant advantage for fiducial-based transformation. In contrast, for t1-weighted gradient-echo imaging with more geometric distortions due to field inhomogenities and gradient nonlinearity than t2-weighted spin-echo imaging, mainly caused by a reduced bandwidth per pixel, anatomical landmark transformation delivered markedly better results. Here, fiducial-based transformation yielded results which are intolerable for stereotactic neurosurgery. Mean Euclidian distances between both transformation methods were 0.96 mm for t2-weighted spin-echo and 1.67 mm for t1-weighted gradient-echo imaging. Maximum deviations were 1.72 mm and 3.06 mm, respectively

  13. MR-guided stereotactic neurosurgery-comparison of fiducial-based and anatomical landmark transformation approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hunsche, S [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Sauner, D [Institute for Diagnostic and Interventional Radiology, Friedrich-Schiller-University of Jena, Jena (Germany); Maarouf, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hoevels, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Luyken, K [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Schulte, O [Department of Radiology, University of Cologne, Cologne (Germany); Lackner, K [Department of Radiology, University of Cologne, Cologne (Germany); Sturm, V [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Treuer, H [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany)

    2004-06-21

    For application in magnetic resonance (MR) guided stereotactic neurosurgery, two methods for transformation of MR-image coordinates in stereotactic, frame-based coordinates exist: the direct stereotactic fiducial-based transformation method and the indirect anatomical landmark method. In contrast to direct stereotactic MR transformation, indirect transformation is based on anatomical landmark coregistration of stereotactic computerized tomography and non-stereotactic MR images. In a patient study, both transformation methods have been investigated with visual inspection and mutual information analysis. Comparison was done for our standard imaging protocol, including t2-weighted spin-echo as well as contrast enhanced t1-weighted gradient-echo imaging. For t2-weighted spin-echo imaging, both methods showed almost similar and satisfying performance with a small, but significant advantage for fiducial-based transformation. In contrast, for t1-weighted gradient-echo imaging with more geometric distortions due to field inhomogenities and gradient nonlinearity than t2-weighted spin-echo imaging, mainly caused by a reduced bandwidth per pixel, anatomical landmark transformation delivered markedly better results. Here, fiducial-based transformation yielded results which are intolerable for stereotactic neurosurgery. Mean Euclidian distances between both transformation methods were 0.96 mm for t2-weighted spin-echo and 1.67 mm for t1-weighted gradient-echo imaging. Maximum deviations were 1.72 mm and 3.06 mm, respectively.

  14. Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

    International Nuclear Information System (INIS)

    Lawton, Colleen A.; Hunt, Daniel; Lee, W. Robert; Gomella, Leonard; Grignon, David; Gillin, Michael; Morton, Gerard; Pisansky, Thomas M.; Sandler, Howard

    2011-01-01

    Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I 125 implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of ≤10 ng/ml; and a Gleason score of ≤6. All patients underwent transrectal ultrasound-guided radioactive I 125 seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable

  15. A simulation technique for 3D MR-guided acoustic radiation force imaging

    International Nuclear Information System (INIS)

    Payne, Allison; Bever, Josh de; Farrer, Alexis; Coats, Brittany; Parker, Dennis L.; Christensen, Douglas A.

    2015-01-01

    Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation force field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through comparison

  16. Out of the black box: expansion of a theory-based intervention to self-manage the uncertainty associated with active surveillance (AS) for prostate cancer.

    Science.gov (United States)

    Kazer, Meredith Wallace; Bailey, Donald E; Whittemore, Robin

    2010-01-01

    Active surveillance (AS) (sometimes referred to as watchful waiting) is an alternative approach to managing low-risk forms of prostate cancer. This management approach allows men to avoid expensive prostate cancer treatments and their well-documented adverse events of erectile dysfunction and incontinence. However, AS is associated with illness uncertainty and reduced quality of life (QOL; Wallace, 2003). An uncertainty management intervention (UMI) was developed by Mishel et al. (2002) to manage uncertainty in women treated for breast cancer and men treated for prostate cancer. However, the UMI was not developed for men undergoing AS for prostate cancer and has not been adequately tested in this population. This article reports on the expansion of a theory-based intervention to manage the uncertainty associated with AS for prostate cancer. Intervention Theory (Sidani & Braden, 1998) is discussed as a framework for revising the UMI intervention for men undergoing AS for prostate cancer (UMI-AS). The article concludes with plans for testing of the expanded intervention and implications for the extended theory.

  17. Role of CT in patients with prostatic disease

    International Nuclear Information System (INIS)

    Yoshizako, Takeshi; Sugimura, Kazuro; Kaji, Yasushi; Moriyama, Masahiro; Ishida, Tetsuya

    1994-01-01

    The purpose of this study was to evaluate the role of CT in patients with and without prostatic disease. CT and MR findings were reviewed in 25 patients without known prostatic disease, 11 patients with benign prostatic hyperplasia and 11 patients with prostatic cancer. Differential attenuation allowed for distinction of the peripheral zone and inner gland of the prostate by CT in 72% of normal patients. The distinction rate of prostatic zonal anatomy by CT decreased to 30% in the diseased group. When zonal anatomy of the prostate is not visualized on pelvic enhanced CT, the presence of prostatic disease might be considered. (author)

  18. MR spectroscopy in diagnosis of local recurrence of T3N0M0 of prostate cancer after cryotherapy

    International Nuclear Information System (INIS)

    Liu Ming; Guo Zhi; Si Tongguo; Wang Haitao; Xiao Bohan

    2012-01-01

    Objective: To evaluate the usefulness of magnetic resonance spectroscopic imaging in detecting local recurrence in patients with T 3 N 0 M 0 prostate cancer after cryotherapy. Methods: Sixty-five patients with T 3 N 0 M 0 prostate cancer underwent cryotherapy. The preoperative data of conventional MRI, MRS, transrectal ultrasound (TRUS)-guided prostate biopsy were collected. After cryotherapy, the prostate specific antigen (PSA) of all patients was detected monthly.If PSA >5 μg/L, MRI, MRS, and TRUS-guided prostate biopsy were planned within a week. If PSA was unremarkable, MRI, MRS, and TRUS-guided prostate biopsy were planned 12 months after cryotherapy. The prostate was divided 6 regions and the cancerous and noncancerous were marked. The signal-to-noise ratio (S/N) of choline (Cho), citrate (Cit) and the ratios of Cho + creatine (Cre)/Cit of each regions were measured in pre-operation and postoperation. The patients were divided into non-recurrence and recurrence group according to TRUS-guided biopsy. The S/N of Cho, Cit, and the ratio of Cho + Cre/Cit were compared between the groups before and after cryotherapy by using independent samples t-test. Results: (1) Fifteen patients were confirmed local recurrence 12 months after cryotherapy, including 11 patients with an evaluate PSA level and 4 patients with PSA unremarkable. (2) The S/N of Cho, Cit and the ratios of Cho + Cre/Cit in the cancerous and noncancerous regions before cryotherapy in the sixty-five patients were 25±9, 11±5, and 18±5, and 39 ±12, 2.33±0.60, and 0.53 ± 0.19. There had significant difference between that of two groups (t values were 11.36, 9.81, and 13.39, respectively, P=0.00). (3) In the patients with non-recurrence, The S/N of Cho, Cit in the cancerous and noncancerous regions were 4 ± 2 and 3 ± 2 (t=1.024, P=0.305), and 2±2 and 4 ±3 (t=1.147, P=0.178) and no difference was found. In necrotic area,the ratios of Cho + Cre/Cit could not be calculated because of low level of the

  19. MR-Guided vacuum biopsy of 206 contrast-enhancing breast lesions; MRT-gefuehrte Vakuumbiopsie bei 206 Kontrastmittel anreichernden Laesionen der Mamma

    Energy Technology Data Exchange (ETDEWEB)

    Perlet, C.; Schneider, P.; Sittek, H.; Reiser, M.F. [Klinikum der Universitaet Grosshadern, Muenchen (Germany). Inst. fuer Klinische Radiologie; Amaya, B.; Grosse, A.; Heywang-Koebrunner, S.H. [Martin-Luther-Universitaet, Halle (Germany). Klinik fuer Diagnostische Radiologie

    2002-01-01

    Purpose: To determine the accuracy and clinical use of MR-guided vacuum biopsy (VB) of enhancing breast lesions. Material and Methods: 254 lesions were referred to MR-guided vacuum-assisted breast biopsy. In 43 (16%) patients the indication was dropped because the lesions could not be identified at the time VB was scheduled. This was due to hormonal influences (n=37), to too strong compression (n=3) or to misinterpretation of the initial diagnostic MRI. In 5 cases (2%) VB was not performed due to obesity (n=2); problems of access (n=2) or a defect of the MR-unit (n=1). VB was performed on altogether 206 lesions. In 4 cases (2%) VB was unsuccessful. This was immediately realized on the post-interventional images. Thus a false negative diagnosis was avoided. Verification included excision of the cavity in cases with proven malignancy or atypical ductal hyperplasia (ADH) and (for benign lesions) retrospective correlation of VB-histology with pre- and postinterventional MRI and subsequent follow-up. Results: 51/202 successful biopsies proved malignancy. In 7 cases ADH and in 144 cases a benign lesion was diagnosed. One DCIS was underestimated as ADH. All other benign or malignant diagnoses proved to be correct. Conclusion: MR-guided VB allows reliable histological work-up of contrast-enhancing small lesions which are not visible by any other modality. (orig.) [German] Zielsetzung: Evaluation der Wertigkeit und klinischen Anwendbarkeit der MRT-gefuehrten Vakuumbiopsie (VB) bei anreichernden Mammalaesionen. Material und Methoden: Insgesamt wurden 254 Laesionen der MRT-gefuehrten VB zugewiesen. Hiervon entfiel bei 43 Patientinnen (16%) die Biopsieindikation beim Planungs-MRT, da die urspruengliche Anreicherung hormonell (n=37), durch zu starke Kompression (n=3) oder durch eine Fehlinterpretation des vorausgegangenen diagnostischen MRT (n=3) nicht mehr abgrenzbar war. Bei 5 weiteren Laesionen (2%) war die Biopsie nicht moeglich (Adipositas n=2; Zugangsprobleme n=2; MRT

  20. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  1. A randomised controlled trial of a cognitive behavioural intervention for men who have hot flushes following prostate cancer treatment (MANCAN: trial protocol

    Directory of Open Access Journals (Sweden)

    Yousaf Omar

    2012-06-01

    Full Text Available Abstract Background This randomised controlled trial (RCT aims to evaluate the effectiveness of a guided self-help cognitive behavioural intervention to alleviate problematic hot flushes (HF and night sweats (NS in men who are undergoing prostate cancer treatment. The trial and the self-help materials have been adapted from a previous RCT, which showed that a cognitive behavioural intervention reduced the self-reported problem-rating of hot flushes in women with menopausal symptoms, and in women undergoing breast cancer treatment. We hypothesize that guided self-help will be more effective than usual care in reducing HF/NS problem-rating at post treatment assessment. Methods/Design Seventy men who are undergoing treatment for prostate cancer and who have been experiencing more than ten HF/NS weekly for over a month are recruited into the trial from urology clinics in London. They are randomly allocated to either a four-week self-help cognitive behavioural therapy (CBT treatment or to their usual care (control group. The treatment includes information and discussion about hot flushes and night sweats in the context of prostate cancer, monitoring and modifying precipitants, relaxation and paced respiration, stress management, cognitive therapy for unhelpful thoughts and beliefs, managing sleep and night sweats, and advice on maintaining these changes. Prior to randomisation, men attend a clinical interview, undergo 24-48-hour sternal skin conductance monitoring, and complete pre-treatment questionnaires (e.g., problem-rating and frequency of hot flushes and night sweats; quality of life; mood; hot flush beliefs and behaviours. Post-treatment measures (sternal skin conductance and the above questionnaires are collected four-six weeks later, and again at a six-month follow-up. Discussion MANCAN is the first randomised controlled trial of cognitive behavioural therapy for HF/NS for men that measures both self-reported and physiologically indexed

  2. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S.; Iordachita, Iulian; Seifabadi, Reza; Cho, Bong Joon; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2013-01-01

    Purpose To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. Methods We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle towards a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between −5.7° and 5.7° horizontally and between −5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. Results The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5 mm along the horizontal axis and 0.8 ± 0.8 mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4 mm. Conclusions Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study. PMID:22678723

  3. A haptic unit designed for magnetic-resonance-guided biopsy.

    Science.gov (United States)

    Tse, Z T H; Elhawary, H; Rea, M; Young, I; Davis, B L; Lamperth, M

    2009-02-01

    The magnetic fields present in the magnetic resonance (MR) environment impose severe constraints on any mechatronic device present in its midst, requiring alternative actuators, sensors, and materials to those conventionally used in traditional system engineering. In addition the spatial constraints of closed-bore scanners require a physical separation between the radiologist and the imaged region of the patient. This configuration produces a loss of the sense of touch from the target anatomy for the clinician, which often provides useful information. To recover the force feedback from the tissue, an MR-compatible haptic unit, designed to be integrated with a five-degrees-of-freedom mechatronic system for MR-guided prostate biopsy, has been developed which incorporates position control and force feedback to the operator. The haptic unit is designed to be located inside the scanner isocentre with the master console in the control room. MR compatibility of the device has been demonstrated, showing a negligible degradation of the signal-to-noise ratio and virtually no geometric distortion. By combining information from the position encoder and force sensor, tissue stiffness measurement along the needle trajectory is demonstrated in a lamb liver to aid diagnosis of suspected cancerous tissue.

  4. SU-G-JeP2-14: MRI-Based HDR Prostate Brachytherapy: A Phantom Study for Interstitial Catheter Reconstruction with 0.35T MRI Images

    International Nuclear Information System (INIS)

    Park, S; Kamrava, M; Yang, Y

    2016-01-01

    Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI was acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.

  5. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  6. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    Science.gov (United States)

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  7. Magnetic Resonance-Based Treatment Planning for Prostate Intensity-Modulated Radiotherapy: Creation of Digitally Reconstructed Radiographs

    International Nuclear Information System (INIS)

    Chen, Lili; Nguyen, Thai-Binh; Jones, Elan; Chen Zuoqun; Luo Wei; Wang Lu; Price, Robert A.; Pollack, Alan; Ma, C.-M. Charlie

    2007-01-01

    Purpose: To develop a technique to create magnetic resonance (MR)-based digitally reconstructed radiographs (DRR) for initial patient setup for routine clinical applications of MR-based treatment planning for prostate intensity-modulated radiotherapy. Methods and Materials: Twenty prostate cancer patients' computed tomography (CT) and MR images were used for the study. Computed tomography and MR images were fused. The pelvic bony structures, including femoral heads, pubic rami, ischium, and ischial tuberosity, that are relevant for routine clinical patient setup were manually contoured on axial MR images. The contoured bony structures were then assigned a bulk density of 2.0 g/cm 3 . The MR-based DRRs were generated. The accuracy of the MR-based DDRs was quantitatively evaluated by comparing MR-based DRRs with CT-based DRRs for these patients. For each patient, eight measuring points on both coronal and sagittal DRRs were used for quantitative evaluation. Results: The maximum difference in the mean values of these measurement points was 1.3 ± 1.6 mm, and the maximum difference in absolute positions was within 3 mm for the 20 patients investigated. Conclusions: Magnetic resonance-based DRRs are comparable to CT-based DRRs for prostate intensity-modulated radiotherapy and can be used for patient treatment setup when MR-based treatment planning is applied clinically

  8. Early clinical experience with pre-operative MR-guided laser-induced thermotherapy (LITT) of liver metastases

    International Nuclear Information System (INIS)

    Vogl, T.J.; Mueller, P.; Phillip, C.; Roggan, A.; Mack, M.G.; Balzer, J.O.; Eichstaedt, H.; Blumhardt, G.; Lobeck, H.; Felix, R.; Weinhold, N.

    1996-01-01

    Five patients with solitary colorectal liver metastases were treated by means of MR-guided LITT before liver resection. Application time and energy of the Nd:YAG laser (1064 nm) and 10-20 minutes and 4.5-8.8 W. MRT monitoring during the LITT was carried out with temperature-sensitive T 1 weighted sequences (FLASH-2-D, turbo FLASH). The extent of the induced necrosis as seen on MR was compared with the unfixed specimen and with the histopathological findings. The extent of necrosis visible by MRT correlated with the histopathological findings with an accuracy of 95.3±4.2%. Following single treatments (three cases) the metastases suffered a reduction of 24%-55% of their original volume. In two patients a second application produced laser-induced necrosis of 78% and 98% of volume. In these two patients a temperature sound was used for measuring regional heating and showed an exact correlation with MR thermometry. (orig./MG) [de

  9. WE-EF-210-08: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in Ultrasound Images Using Patch-Based Anatomical Feature

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X; Rossi, P; Jani, A; Ogunleye, T; Curran, W; Liu, T [Emory Univ, Atlanta, GA (United States)

    2015-06-15

    Purpose: Transrectal ultrasound (TRUS) is the standard imaging modality for the image-guided prostate-cancer interventions (e.g., biopsy and brachytherapy) due to its versatility and real-time capability. Accurate segmentation of the prostate plays a key role in biopsy needle placement, treatment planning, and motion monitoring. As ultrasound images have a relatively low signal-to-noise ratio (SNR), automatic segmentation of the prostate is difficult. However, manual segmentation during biopsy or radiation therapy can be time consuming. We are developing an automated method to address this technical challenge. Methods: The proposed segmentation method consists of two major stages: the training stage and the segmentation stage. During the training stage, patch-based anatomical features are extracted from the registered training images with patient-specific information, because these training images have been mapped to the new patient’ images, and the more informative anatomical features are selected to train the kernel support vector machine (KSVM). During the segmentation stage, the selected anatomical features are extracted from newly acquired image as the input of the well-trained KSVM and the output of this trained KSVM is the segmented prostate of this patient. Results: This segmentation technique was validated with a clinical study of 10 patients. The accuracy of our approach was assessed using the manual segmentation. The mean volume Dice Overlap Coefficient was 89.7±2.3%, and the average surface distance was 1.52 ± 0.57 mm between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D ultrasound-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning framework, demonstrated its clinical feasibility, and validated its accuracy with manual segmentation (gold standard). This segmentation technique could be a useful

  10. Multiparametric MRI fusion-guided biopsy for the diagnosis of prostate cancer.

    Science.gov (United States)

    Kesch, Claudia; Schütz, Viktoria; Dieffenbacher, Svenja; Bonekamp, David; Hadaschik, Boris Alexander; Hohenfellner, Markus; Radtke, Jan P

    2018-03-01

    To discuss the timing, benefits, limitations and current controversies of multiparametric magnet resonance imaging (mpMRI) combined with fusion-guided biopsy and consider how additional incorporation of multivariable risk stratification might further improve prostate cancer diagnosis. MpMRI has been proven advantageous over standard practice for biopsy-naïve men and men with previous biopsy in large prospective studies providing level 1b evidence. Upfront multivariable risk stratification followed by or combined with mpMRI further improves diagnostic accuracy. Regarding active surveillance, mpMRI in combination with fusion biopsy can support initial candidate selection and may help to monitor disease progression. mpMRI and fusion biopsy, however, do not spare failure and conflicting data exists to what extend (systematic) biopsies can be omitted. Integration of mpMRI into the diagnostic pathway for prostate cancer is beneficial; yet more prospective and randomized data is needed to establish reliable procedure standards after mpMRI acquisition.

  11. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  12. Effectiveness of stress management in patients undergoing transrectal ultrasound-guided biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Chiu LP

    2016-02-01

    Full Text Available Li-Pin Chiu,1,2 Heng-Hsin Tung,3 Kuan-Chia Lin,3 Yu-Wei Lai,1,4 Yi-Chun Chiu,1,4 Saint Shiou-Sheng Chen,1,4 Allen W Chiu1,4 1Division of Urology, Taipei City Hospital, 2University of Taipei, General Education Center, 3School of Nursing, Department of Care Management, National Taipei University of Nursing and Health Science, 4Department of Urology, National Yang-Ming University School of Medicine, Taipei, Taiwan, Republic of China Background: To assess the utilization of stress management in relieving anxiety and pain among patients who undergo transrectal ultrasound (TRUS-guided biopsy of the prostate.  Methods: Eighty-two patients admitted to a community hospital for a TRUS biopsy of the prostate participated in this case-controlled study. They were divided into an experimental group that was provided with stress management and a control group that received only routine nursing care. Stress management included music therapy and one-on-one simulation education. Before and after the TRUS biopsy, the patients’ state-anxiety inventory score, pain visual analogue scale (VAS, respiratory rate, heart rate, and blood pressure were obtained.  Results: There were no differences in baseline and disease characteristics between the two groups. The VAS in both groups increased after the TRUS biopsy, but the difference in pre- and postbiopsy VAS scores was significantly lower in the experimental group (P=0.03. Patients in both groups experienced mild anxiety before and after the biopsy, but those in the experimental group displayed a significantly greater decrease in postbiopsy state-anxiety inventory score compared to the control group (P=0.02.Conclusion: Stress management can alleviate anxiety and pain in patients who received a TRUS biopsy of the prostate under local anesthesia. Keywords: anxiety, pain, stress management, transrectal ultrasound-guided biopsy of the prostate

  13. Where Do Transrectal Ultrasound- and Magnetic Resonance Imaging-guided Biopsies Miss Significant Prostate Cancer?

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    -guided biopsy (reTRUSbx) and targeted mpMRIbx (image fusion) of any suspicious lesion. Biopsy results were compared and the locations of missed sPCa lesions were registered. Cancer significance was defined as (1) any core with a Gleason score of >6, (2) cancer core involvement of ≥50% and for re......TRUSbx on patient level, and (3) the presence of ≥3 positive cores. RESULTS: Of the 289 patients, prostate cancer was detected in 128 (44%) with 88 (30%) having sPCa. Overall, 165 separate prostate cancer lesions were detected with 100 being sPCa. Of these, mpMRIbx and reTRUSbx detected 90% (90/100) and 68% (68...... TRUSbx and mpMRIbx missed sPCa lesions in specific segments of the prostate. Missed sPCa lesions at repeat biopsy were primarily located anteriorly for TRUSbx and posterolateral midprostatic for mpMRIbx. Localization of these segments may improve biopsy techniques in men undergoing repeat biopsies....

  14. Image-guided regularization level set evolution for MR image segmentation and bias field correction.

    Science.gov (United States)

    Wang, Lingfeng; Pan, Chunhong

    2014-01-01

    Magnetic resonance (MR) image segmentation is a crucial step in surgical and treatment planning. In this paper, we propose a level-set-based segmentation method for MR images with intensity inhomogeneous problem. To tackle the initialization sensitivity problem, we propose a new image-guided regularization to restrict the level set function. The maximum a posteriori inference is adopted to unify segmentation and bias field correction within a single framework. Under this framework, both the contour prior and the bias field prior are fully used. As a result, the image intensity inhomogeneity can be well solved. Extensive experiments are provided to evaluate the proposed method, showing significant improvements in both segmentation and bias field correction accuracies as compared with other state-of-the-art approaches. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Role of transurethral resection of the prostate in the management of prostate cancer

    Directory of Open Access Journals (Sweden)

    Szollosi Attila

    2016-06-01

    Full Text Available Introduction: Prostate cancer is the second most diagnosed cancer in men, after lung cancer. The gold standard procedure in prostate cancer (PCa diagnosis is the ultrasound guided prostate biopsy. Transurethral resection of the prostate (TURP used in solving the bladder outlet obstruction, can have a role in detection of PCa. The aim of this retrospective study is to examine the role of transurethral resection of the prostate in the diagnosis and therapy of prostate cancer.

  16. Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mendenhall, Nancy P., E-mail: menden@shands.ufl.edu [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Hoppe, Bradford S.; Nichols, Romaine C.; Mendenhall, William M.; Morris, Christopher G.; Li, Zuofeng; Su, Zhong [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Williams, Christopher R.; Costa, Joseph [Division of Urology, College of Medicine, University of Florida, Jacksonville, Florida (United States); Henderson, Randal H. [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States)

    2014-03-01

    Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes.

  17. Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Mendenhall, Nancy P.; Hoppe, Bradford S.; Nichols, Romaine C.; Mendenhall, William M.; Morris, Christopher G.; Li, Zuofeng; Su, Zhong; Williams, Christopher R.; Costa, Joseph; Henderson, Randal H.

    2014-01-01

    Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes

  18. Nurse-led group consultation intervention reduces depressive symptoms in men with localised prostate cancer: a cluster randomised controlled trial

    International Nuclear Information System (INIS)

    Schofield, Penelope; Gough, Karla; Lotfi-Jam, Kerryann; Bergin, Rebecca; Ugalde, Anna; Dudgeon, Paul; Crellin, Wallace; Schubach, Kathryn; Foroudi, Farshard; Tai, Keen Hun; Duchesne, Gillian; Sanson-Fisher, Rob; Aranda, Sanchia

    2016-01-01

    Radiotherapy for localised prostate cancer has many known and distressing side effects. The efficacy of group interventions for reducing psychological morbidity is lacking. This study investigated the relative benefits of a group nurse-led intervention on psychological morbidity, unmet needs, treatment-related concerns and prostate cancer-specific quality of life in men receiving curative intent radiotherapy for prostate cancer. This phase III, two-arm cluster randomised controlled trial included 331 men (consent rate: 72 %; attrition: 5 %) randomised to the intervention (n = 166) or usual care (n = 165). The intervention comprised four group and one individual consultation all delivered by specialist uro-oncology nurses. Primary outcomes were anxious and depressive symptoms as assessed by the Hospital Anxiety and Depression Scale. Unmet needs were assessed with the Supportive Care Needs Survey-SF34 Revised, treatment-related concerns with the Cancer Treatment Scale and quality of life with the Expanded Prostate Cancer Index −26. Assessments occurred before, at the end of and 6 months post-radiotherapy. Primary outcome analysis was by intention-to-treat and performed by fitting a linear mixed model to each outcome separately using all observed data. Mixed models analysis indicated that group consultations had a significant beneficial effect on one of two primary endpoints, depressive symptoms (p = 0.009), and one of twelve secondary endpoints, procedural concerns related to cancer treatment (p = 0.049). Group consultations did not have a significant beneficial effect on generalised anxiety, unmet needs and prostate cancer-specific quality of life. Compared with individual consultations offered as part of usual care, the intervention provides a means of delivering patient education and is associated with modest reductions in depressive symptoms and procedural concerns. Future work should seek to confirm the clinical feasibility and cost-effectiveness of group

  19. The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach

    Directory of Open Access Journals (Sweden)

    Kevin Krughoff

    2013-01-01

    Full Text Available Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS- guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB provides a more accurate depiction of disease status than transrectal ultrasound- (TRUS- guided biopsy. We compared 3DMB findings in men with prior TRUS-guided biopsies to determine grade and location of missed cancer. Results were evaluated for 161 men with low-risk organ confined prostate cancer. Results. The number of cancer-positive biopsy zones per patient with TRUS was 1.38 ± 1.21 compared to 3.33 ± 4.06 with 3DMB, with most newly discovered cancers originating from the middle lobe and apex. Approximately half of all newly discovered cancerous zones resulted from anterior 3DMB sampling. Gleason upgrade was recognized in 56 patients using 3DMB. When both biopsy methods found positive cores in a given zone, Gleason upgrades occurred most frequently in the middle left and right zones. TRUS cancer-positive zones not confirmed by 3DMB were most often the basal zones. Conclusion. Most cancer upgrades and cancers missed from TRUS biopsy originated in the middle left zone of the prostate, specifically in anterior regions. Anterior sampling may lead to more accurate diagnosis and appropriate followup.

  20. MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), General Hospital Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2014-06-15

    To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI). This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis. Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 x 10{sup -3} mm{sup 2}/s in benign lesions and 1.06 ± 0.27 x 10{sup -3} mm{sup 2}/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 x 10{sup -3} mm{sup 2}/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis. Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols. (orig.)

  1. Sexual potency following interactive ultrasound-guided brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Stock, Richard G.; Stone, Nelson N.; Iannuzzi, Christopher

    1996-01-01

    Purpose: The effect of a therapeutic modality on sexual potency is often an important consideration for patients choosing a treatment for prostate cancer. We prospectively assessed patients' penile erectile function before and following interactive ultrasound-guided transperineal permanent radioactive seed implantation to determine its effect on sexual function. Methods and Materials: Eighty-nine patients underwent permanent radioactive seed implantation from June 1990 to April 1994 for localized prostate cancer (T1-T2) and were followed for a median of 15 months (1.5-52 months). 125 I seeds were implanted in 73 patients with a combined Gleason grade of 2-6, and 103 Pd seeds were implanted in 16 patients with higher grade lesions. The sexual potency of these patients was assessed prior to, at 3 and 6 months, and every 6 months after implantation. Erectile function was graded using a numerical score of 0 to 3 (0 = impotent (no erections), 1 = ability to have erections but insufficient for vaginal penetration, 2 = erectile function sufficient for vaginal penetration but suboptimal, 3 = normal erectile function). The pretreatment potency scores were as follows: 0 in 24 patients, 1 in 6 patients, 2 in 22 patients, and 3 in 37 patients. Results: The actuarial impotency rates (score = 0) following implantation for those patients possessing some degree of erectile function prior to implantation (65 patients) were 2.5% at 1 year and 6% at 2 years. The actuarial decrease in sexual function rates (a drop in score of at least one point) were 29% at 1 year and 39% at 2 years. Only two patients became impotent following treatment and this occurred at 1 year and 16 months. The time period for a decrease in erectile function to occur ranged from 1.8 months to 32.7 months, with a median of 6.8 months. Patients with higher grade tumors showed a greater decrease in potency score compared to patients with lower grade tumors. Conclusion: Interactive ultrasound-guided transperineal

  2. Bladder outlet obstruction due to a small midline prostatic cyst - diagnostic imaging and interventional radiological treatment

    International Nuclear Information System (INIS)

    Hueppe, T.; Kopka, L.; Friedrich, M.; Kuehn, M.

    1992-01-01

    We describe a rare case of a bladder outlet obstruction due to a midline prostatic cyst. In the following clinical apperance, diagnostic imaging and therapy by CT-guided punction are reported. Differential diagnosis and therapy are discussed. (orig.) [de

  3. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G; Kadbi, M; Blencowe, A

    2016-01-01

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe 3+ ) reduction versus ferrous ion (Fe 2+ ) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T 1 -weighted and inversion recovery sequences). Results: Irradiation of Fe 3+ reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R 2 =1.00). T 1 -weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe 2+ oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T 1 -weighted-MR SI, and R 1 relative to dose exhibited a linear response up to at least 8 Gy (R 2 =1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T 1 -weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R 2 >0.93). Conclusion: The Fe 2+ oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe 3+ reduction system is recommended for high

  4. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States); Kadbi, M [MR Therapy, Philips healthTech, Cleveland, OH (United States); Blencowe, A [The University of South Australia, South Australia, SA (Australia)

    2016-06-15

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose

  5. Evaluation of permanent I-125 prostate implants using radiographs and MRI

    International Nuclear Information System (INIS)

    Moerland, M.A.; Beersma, R.; Bhagwandien, R.; Wijrdeman, H.K.; Battermann, J.J.

    1995-01-01

    Introduction: Localized prostatic cancer is managed by radical prostatectomy, external beam irradiation or a permanent implant with I-125 seeds. Permanent implants are indicated for small tumours (T1-T2) with a well to moderate histological differentiation. The technique used is a transrectal ultrasound guided transperineal implantation technique, which aims for a seed and dose distribution such that the initial doserate line of 7.8 cGy/h encompasses the prostate resulting in an accumulated dose of 160 Gy. Up till now the seed and dose distribution is evaluated from isocentric radiographs, which do not show the relation with the prostate. Objectives: The aim of this study is the development of a technique to reconstruct and evaluate the seed and dose distribution within the prostate. Methods: Twenty patients underwent radiography on the simulator and scanning on a whole body NMR system within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the MR images provided the seed positions in relation to the prostate. Volume dose histograms were used to evaluate the implants. Results: The I-125 seeds and the prostate anatomy were well depicted on T1-weighted spin echo images with minimal read out gradient strength. To date, ten implants were evaluated. According to our method, the prostate volumes receiving the prescribed dose of 160 Gy ranged from 30 to 70% of the total prostate volumes. Conclusion: The combination of isocentric radiographs and MRI enables reconstruction of the seed and dose distribution in relation to the prostate and the computation of dose volume histograms, which may be of value in the evaluation of implant quality

  6. 18F-fluorocholine PET-guided target volume delineation techniques for partial prostate re-irradiation in local recurrent prostate cancer

    International Nuclear Information System (INIS)

    Wang Hui; Vees, Hansjoerg; Miralbell, Raymond; Wissmeyer, Michael; Steiner, Charles; Ratib, Osman; Senthamizhchelvan, Srinivasan; Zaidi, Habib

    2009-01-01

    Background and purpose: We evaluate the contribution of 18 F-choline PET/CT in the delineation of gross tumour volume (GTV) in local recurrent prostate cancer after initial irradiation using various PET image segmentation techniques. Materials and methods: Seventeen patients with local-only recurrent prostate cancer (median = 5.7 years) after initial irradiation were included in the study. Rebiopsies were performed in 10 patients that confirmed the local recurrence. Following injection of 300 MBq of 18 F-fluorocholine, dynamic PET frames (3 min each) were reconstructed from the list-mode acquisition. Five PET image segmentation techniques were used to delineate the 18 F-choline-based GTVs. These included manual delineation of contours (GTV man ) by two teams consisting of a radiation oncologist and a nuclear medicine physician each, a fixed threshold of 40% and 50% of the maximum signal intensity (GTV 40% and GTV 50% ), signal-to-background ratio-based adaptive thresholding (GTV SBR ), and a region growing (GTV RG ) algorithm. Geographic mismatches between the GTVs were also assessed using overlap analysis. Results: Inter-observer variability for manual delineation of GTVs was high but not statistically significant (p = 0.459). In addition, the volumes and shapes of GTVs delineated using semi-automated techniques were significantly higher than those of GTVs defined manually. Conclusions: Semi-automated segmentation techniques for 18 F-choline PET-guided GTV delineation resulted in substantially higher GTVs compared to manual delineation and might replace the latter for determination of recurrent prostate cancer for partial prostate re-irradiation. The selection of the most appropriate segmentation algorithm still needs to be determined.

  7. 18F-fluorocholine PET-guided target volume delineation techniques for partial prostate re-irradiation in local recurrent prostate cancer.

    Science.gov (United States)

    Wang, Hui; Vees, Hansjörg; Miralbell, Raymond; Wissmeyer, Michael; Steiner, Charles; Ratib, Osman; Senthamizhchelvan, Srinivasan; Zaidi, Habib

    2009-11-01

    We evaluate the contribution of (18)F-choline PET/CT in the delineation of gross tumour volume (GTV) in local recurrent prostate cancer after initial irradiation using various PET image segmentation techniques. Seventeen patients with local-only recurrent prostate cancer (median=5.7 years) after initial irradiation were included in the study. Rebiopsies were performed in 10 patients that confirmed the local recurrence. Following injection of 300 MBq of (18)F-fluorocholine, dynamic PET frames (3 min each) were reconstructed from the list-mode acquisition. Five PET image segmentation techniques were used to delineate the (18)F-choline-based GTVs. These included manual delineation of contours (GTV(man)) by two teams consisting of a radiation oncologist and a nuclear medicine physician each, a fixed threshold of 40% and 50% of the maximum signal intensity (GTV(40%) and GTV(50%)), signal-to-background ratio-based adaptive thresholding (GTV(SBR)), and a region growing (GTV(RG)) algorithm. Geographic mismatches between the GTVs were also assessed using overlap analysis. Inter-observer variability for manual delineation of GTVs was high but not statistically significant (p=0.459). In addition, the volumes and shapes of GTVs delineated using semi-automated techniques were significantly higher than those of GTVs defined manually. Semi-automated segmentation techniques for (18)F-choline PET-guided GTV delineation resulted in substantially higher GTVs compared to manual delineation and might replace the latter for determination of recurrent prostate cancer for partial prostate re-irradiation. The selection of the most appropriate segmentation algorithm still needs to be determined.

  8. Dosimetric implications of residual seminal vesicle motion in fiducial-guided intensity-modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Stenmark, Matthew H.; Vineberg, Karen; Ten Haken, Randall K.; Hamstra, Daniel A.; Feng, Mary

    2012-01-01

    To determine whether residual interfraction seminal vesicle (SV) displacement necessitates specific planning target volume (PTV) margins during fiducial-guided intensity modulated radiation therapy (IMRT) of the prostate. A planning computed tomography (CT) scan and 2 subsequent CT scans were prospectively obtained for 20 prostate cancer patients with intraprostatic fiducial markers. After CT registration, SV displacement relative to the prostate was quantified as a function of margin size for both the proximal (1 cm) SV (PSV) and the full SV (FSV). Two IMRT plans were simulated for each patient (prostate + PSV and prostate + FSV) both with a uniform 5-mm PTV margin. Minimum clinical target volume (CTV) dose (D min ) and the volume of SV receiving 95% of the prescription dose (V 95% ) were assessed during treatment and compared with the initial plan. In all cases, SV displacement with respect to the prostate was greater for the FSV compared with the PSV. To ensure at least 95% geometrical coverage of the CTV for 90% of patients, margins of 5 and 8 mm were required for the PSV and FSV, respectively. Dosimetrically, residual SV displacement had minimal impact on PSV coverage compared with FSV coverage. For the PSV D min was ≥95% of the prescribed dose in 90% of patients with an overall mean V 95% of 99.6 ± 0.8%; for the FSV D min was ≥95% of the prescribed dose in only 45% of patients with a mean V 95% of 97.9 ± 2.4%. The SVs move differentially from the prostate and exhibit greater variation with increasing distance from the prostate. For plans targeting just the prostate and PSVs, 5-mm PTV expansions are adequate. However, despite daily localization of the prostate, larger PTV margins are required for cases where the intent is to completely cover the FSV.

  9. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  10. In vivo optoacoustic temperature imaging for image-guided cryotherapy of prostate cancer

    Science.gov (United States)

    Petrova, E. V.; Brecht, H. P.; Motamedi, M.; Oraevsky, A. A.; Ermilov, S. A.

    2018-03-01

    The objective of this study is to demonstrate in vivo the feasibility of optoacoustic temperature imaging during cryotherapy of prostate cancer. We developed a preclinical prototype optoacoustic temperature imager that included pulsed optical excitation at a wavelength of 805 nm, a modified clinical transrectal ultrasound probe, a parallel data acquisition system, image processing and visualization software. Cryotherapy of a canine prostate was performed in vivo using a commercial clinical system, Cryocare® CS, with an integrated ultrasound imaging. The universal temperature-dependent optoacoustic response of blood was employed to convert reconstructed optoacoustic images to temperature maps. Optoacoustic imaging of temperature during prostate cryotherapy was performed in the longitudinal view over a region of 30 mm (long)  ×  10 mm (deep) that covered the rectum, the Denonvilliers fascia, and the posterior portion of the treated gland. The transrectal optoacoustic images showed high-contrast vascularized regions, which were used for quantitative estimation of local temperature profiles. The constructed temperature maps and their temporal dynamics were consistent with the arrangement of the cryoprobe and readouts of the thermal needle sensors. The temporal profiles of the readouts from the thermal needle sensors and the temporal profile estimated from the normalized optoacoustic intensity of the selected vascularized region showed significant resemblance, except for the initial overshoot, that may be explained as a result of the physiological thermoregulatory compensation. The temperature was mapped with errors not exceeding  ±2 °C (standard deviation) consistent with the clinical requirements for monitoring cryotherapy of the prostate. In vivo results showed that the optoacoustic temperature imaging is a promising non-invasive technique for real-time imaging of tissue temperature during cryotherapy of prostate cancer, which can be combined

  11. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  12. 1.5 T conventional MR-guided iodine-125 interstitial implants for hepatocellular carcinoma: Feasibility and preliminary clinical experience

    International Nuclear Information System (INIS)

    Lin Zhengyu; Lin Jun; Lin Cong; Li Yinguan; Chen Shaoming; Hu Jianping; Hu Rui; Chen Jin

    2012-01-01

    Purpose: To evaluate the feasibility and therapeutic efficacy of 1.5 T conventional MR-guided percutaneous interstitial implantation of I-125 radioactive seeds in patients with hepatocellular carcinoma (HCC). Materials and methods: The institutional ethics committee approved this study. After imformed consent was obtained, twenty-three patients suffering from a total of 65 HCC lesions were treated with I-125 seed permanent interstitial implantation under the guidance of a 1.5 T conventional magnetic resonance imaging (MRI) system. The FSE T2WI, T1 FSPGR, FIESTA 2D, 3D Dyn T1WI sequences were used to guide an 18G MR-compatible needle inserted into the lesions to introduce the I-125 seeds. The response evaluation criteria in solid tumors (RECIST) were used to evaluate the curative effect. Results: The needle and I-125 seed were seen clearly on MRI images. The final dose delivered to total decay was 173.46 ± 32.44 Gy (range, 110–270 Gy) as calculated by postoperative TPS. The complete response (CR) was seen in 22 lesions (33.8%), partial response (PR) in 24 lesions (36.9%), stable disease (SD) in 9 lesions (13.8%), and progressive disease (PD) in 10 lesions (15.4%). The post-operative alpha-fetoprotein (AFP) was decreased (t = 3.117, P = 0.005 < 0.05). Two patients were observed a small area of subcapsular bleeding that did not lead to any symptoms or clinical sequelae. Conclusion: MR-guided I-125 implantation for HCC is technically feasible and effective.

  13. Evaluation of volume change in rectum and bladder during application of image-guided radiotherapy for prostate carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Luna, J. A., E-mail: yosimoon13@hotmail.com [Departamento de Física, Universidad Nacional de Costa Rica, Heredia (Costa Rica); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XX1, La Uruca (Costa Rica); PROXTRONICS CR, Ltda, Heredia (Costa Rica)

    2016-07-07

    All prostate cancer patients from Centro Médico Radioterapia Siglo XXI receive Volumetric Modulated Arc Therapy (VMAT). This therapy uses image-guided radiotherapy (IGRT) with the Cone Beam Computed Tomography (CBCT). This study compares the planned dose in the reference CT image against the delivered dose recalculate in the CBCT image. The purpose of this study is to evaluate the anatomic changes and related dosimetric effect based on weekly CBCT directly for patients with prostate cancer undergoing volumetric modulated arc therapy (VMAT) treatment. The collected data were analyzed using one-way ANOVA.

  14. Experimental investigations of an endoluminal ultrasound applicator for MR-guided thermal therapy of pancreatic cancer

    Science.gov (United States)

    Adams, Matthew; Salgaonkar, Vasant; Jones, Peter; Plata, Juan; Chen, Henry; Pauly, Kim Butts; Sommer, Graham; Diederich, Chris

    2017-03-01

    An MR-guided endoluminal ultrasound applicator has been proposed for palliative and potential curative thermal therapy of pancreatic tumors. Minimally invasive ablation or hyperthermia treatment of pancreatic tumor tissue would be performed with the applicator positioned in the gastrointestinal (GI) lumen, and sparing of the luminal tissue would be achieved with a water-cooled balloon surrounding the ultrasound transducers. This approach offers the capability of conformal volumetric therapy for fast treatment times, with control over the 3D spatial deposition of energy. Prototype endoluminal ultrasound applicators have been fabricated using 3D printed fixtures that seat two 3.2 or 5.6 MHz planar or curvilinear transducers and contain channels for wiring and water flow. Spiral surface coils have been integrated onto the applicator body to allow for device localization and tracking for therapies performed under MR guidance. Heating experiments with a tissue-mimicking phantom in a 3T MR scanner were performed and demonstrated capability of the prototype to perform volumetric heating through duodenal luminal tissue under real-time PRF-based MR temperature imaging (MRTI). Additional experiments were performed in ex vivo pig carcasses with the applicator inserted into the esophagus and aimed towards liver or soft tissue surrounding the spine under MR guidance. These experiments verified the capacity of heating targets up to 20-25 mm from the GI tract. Active device tracking and automated prescription of imaging and temperature monitoring planes through the applicator were made possible by using Hadamard encoded tracking sequences to obtain the coordinates of the applicator tracking coils. The prototype applicators have been integrated with an MR software suite that performs real-time device tracking and temperature monitoring.

  15. Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis

    International Nuclear Information System (INIS)

    Fritz, J.; Tzaribachev, N.; Thomas, C.; Claussen, C.D.; Carrino, J.A.; Lewin, J.S.; Pereira, P.L.

    2011-01-01

    To test the hypothesis that MR imaging guided triamcinolone acetonide injection into the sacroiliac joints of children with enthesitis-related arthritis is feasible, accurate and safe; and effectively reduces sacroiliac inflammation and disease progression. A retrospective analysis of 14 children (6/14 [43%] female, 8/14 (57%) male; mean age, 13.2 years; range, 6-16 years) who received MR imaging guided sacroiliac joint injections at 0.2 Tesla or 1.5 Tesla for enthesitis-related arthritis and acute sacroilitis refractory to medical therapy was performed. 20 mg triamcinolone acetonide were injected. Assessed were intra-articular drug delivery; image quality, duration, and complications. Success of therapy was defined by change of sacroiliac inflammation. Remission time and erosions were assessed by follow-up MRI (range, 10-22 months). Twenty four procedures resulted in intra-articular injection. Image quality was sufficient. No complications occurred. Procedure time was 40 min. Sedation time was 22 min. Success of therapy was achieved in 11/14 (79%) children. Sacroiliac inflammation decreased significantly (-59%). Median remission time was 13.7 months. No erosions occurred. MR imaging guided steroid injection of the sacroiliac joints is feasible, accurate, and safe and can effectively reduce sacroiliac inflammatory activity and may therefore aid in the prevention of disease progression. (orig.)

  16. Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Eberhard-Karls-University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Tzaribachev, N. [Eberhard-Karls-University Tuebingen, Department of Hematology, Oncology and General Pediatrics, University Children' s Hospital, Tuebingen (Germany); Klinikum Bad Bramstedt, Department of Pediatric Rheumatology, Bad Bramstedt (Germany); Thomas, C.; Claussen, C.D. [Eberhard-Karls-University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Carrino, J.A.; Lewin, J.S. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Pereira, P.L. [Eberhard-Karls-University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); SLK-Kliniken Heilbronn, Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, Heilbronn (Germany)

    2011-05-15

    To test the hypothesis that MR imaging guided triamcinolone acetonide injection into the sacroiliac joints of children with enthesitis-related arthritis is feasible, accurate and safe; and effectively reduces sacroiliac inflammation and disease progression. A retrospective analysis of 14 children (6/14 [43%] female, 8/14 (57%) male; mean age, 13.2 years; range, 6-16 years) who received MR imaging guided sacroiliac joint injections at 0.2 Tesla or 1.5 Tesla for enthesitis-related arthritis and acute sacroilitis refractory to medical therapy was performed. 20 mg triamcinolone acetonide were injected. Assessed were intra-articular drug delivery; image quality, duration, and complications. Success of therapy was defined by change of sacroiliac inflammation. Remission time and erosions were assessed by follow-up MRI (range, 10-22 months). Twenty four procedures resulted in intra-articular injection. Image quality was sufficient. No complications occurred. Procedure time was 40 min. Sedation time was 22 min. Success of therapy was achieved in 11/14 (79%) children. Sacroiliac inflammation decreased significantly (-59%). Median remission time was 13.7 months. No erosions occurred. MR imaging guided steroid injection of the sacroiliac joints is feasible, accurate, and safe and can effectively reduce sacroiliac inflammatory activity and may therefore aid in the prevention of disease progression. (orig.)

  17. Treatment outcome of high-dose image-guided intensity-modulated radiotherapy using intra-prostate fiducial markers for localized prostate cancer at a single institute in Japan

    International Nuclear Information System (INIS)

    Takeda, Ken; Shimizu, Eiji; Abe, Keiko; Shirata, Yuko; Ishikawa, Yohjiro

    2012-01-01

    Several studies have confirmed the advantages of delivering high doses of external beam radiotherapy to achieve optimal tumor-control outcomes in patients with localized prostate cancer. We evaluated the medium-term treatment outcome after high-dose, image-guided intensity-modulated radiotherapy (IMRT) using intra-prostate fiducial markers for clinically localized prostate cancer. In total, 141 patients with localized prostate cancer treated with image-guided IMRT (76 Gy in 13 patients and 80 Gy in 128 patients) between 2003 and 2008 were enrolled in this study. The patients were classified according to the National Comprehensive Cancer Network-defined risk groups. Thirty-six intermediate-risk patients and 105 high-risk patients were included. Androgen-deprivation therapy was performed in 124 patients (88%) for a median of 11 months (range: 2–88 months). Prostate-specific antigen (PSA) relapse was defined according to the Phoenix-definition (i.e., an absolute nadir plus 2 ng/ml dated at the call). The 5-year actuarial PSA relapse-free survival, the 5-year distant metastasis-free survival, the 5-year cause-specific survival (CSS), the 5-year overall survival (OS) outcomes and the acute and late toxicities were analyzed. The toxicity data were scored according to the Common Terminology Criteria for Adverse Events, version 4.0. The median follow-up was 60 months. The 5-year PSA relapse-free survival rates were 100% for the intermediate-risk patients and 82.2% for the high-risk patients; the 5-year actuarial distant metastasis-free survival rates were 100% and 95% for the intermediate- and high-risk patients, respectively; the 5-year CSS rates were 100% for both patient subsets; and the 5-year OS rates were 100% and 91.7% for the intermediate- and high-risk patients, respectively. The Gleason score (<8 vs. ≥8) was significant for the 5-year PSA relapse-free survival on multivariate analysis (p = 0.044). There was no grade 3 or 4 acute toxicity. The incidence of

  18. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    Science.gov (United States)

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Automatic localization of the prostate for on-line or off-line image-guided radiotherapy

    International Nuclear Information System (INIS)

    Smitsmans, Monique H.P.; Wolthaus, Jochem W.H.; Artignan, Xavier; Bois, Josien de; Jaffray, David A.; Lebesque, Joos V.; Herk, Marcel van

    2004-01-01

    Purpose: With higher radiation dose, higher cure rates have been reported in prostate cancer patients. The extra margin needed to account for prostate motion, however, limits the level of dose escalation, because of the presence of surrounding organs at risk. Knowledge of the precise position of the prostate would allow significant reduction of the treatment field. Better localization of the prostate at the time of treatment is therefore needed, e.g. using a cone-beam computed tomography (CT) system integrated with the linear accelerator. Localization of the prostate relies upon manual delineation of contours in successive axial CT slices or interactive alignment and is fairly time-consuming. A faster method is required for on-line or off-line image-guided radiotherapy, because of prostate motion, for patient throughput and efficiency. Therefore, we developed an automatic method to localize the prostate, based on 3D gray value registration. Methods and materials: A study was performed on conventional repeat CT scans of 19 prostate cancer patients to develop the methodology to localize the prostate. For each patient, 8-13 repeat CT scans were made during the course of treatment. First, the planning CT scan and the repeat CT scan were registered onto the rigid bony structures. Then, the delineated prostate in the planning CT scan was enlarged by an optimum margin of 5 mm to define a region of interest in the planning CT scan that contained enough gray value information for registration. Subsequently, this region was automatically registered to a repeat CT scan using 3D gray value registration to localize the prostate. The performance of automatic prostate localization was compared to prostate localization using contours. Therefore, a reference set was generated by registering the delineated contours of the prostates in all scans of all patients. Gray value registrations that showed large differences with respect to contour registrations were detected with a χ 2

  20. Characterization of the first RF coil dedicated to 1.5 T MR guided radiotherapy

    Science.gov (United States)

    Hoogcarspel, Stan J.; Zijlema, Stefan E.; Tijssen, Rob H. N.; Kerkmeijer, Linda G. W.; Jürgenliemk-Schulz, Ina M.; Lagendijk, Jan J. W.; Raaymakers, Bas W.

    2018-01-01

    The purpose of this study is to investigate the attenuation characteristics of a novel radiofrequency (RF) coil, which is the first coil that is solely dedicated to MR guided radiotherapy with a 1.5 T MR-linac. Additionally, we investigated the impact of the treatment beam on the MRI performance of this RF coil. First, the attenuation characteristics of the RF coil were characterized. Second, we investigated the impact of the treatment beam on the MRI performance of the RF coil. We additionally demonstrated the ability of the anterior coil to attenuate returning electrons and thereby reducing the dose to the skin at the distal side of the treatment beam. Intensity modulated radiation therapy simulation of a clinically viable treatment plan for spinal bone metastasis shows a decrease of the dose to the planned tumor volume of 1.8% as a result of the MR coil around the patient. Ionization chamber and film measurements show that the anterior and posterior coil attenuate the beam homogeneously by 0.4% and 2.2%, respectively. The impact of the radiation resulted in a slight drop of the time-course signal-to-noise ratio and was dependent on imaging parameters. However, we could not observe any image artifacts resulting from this irradiation in any situation. In conclusion, the investigated MR-coil can be utilized for treatments with the 1.5 T-linac system. However, there is still room for improvement when considering both the dosimetric and imaging performance of the coil.

  1. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2004-01-01

    The goal of the current research is the development of a magnetic nanoparticle based MR contrast agent that binds the gastrin releasing peptide receptor, a molecular marker associated with neoplasia...

  2. Evaluation of semi-quantitative parameters of prostate MR spectroscopy: comparison with biopsy

    International Nuclear Information System (INIS)

    Wang Cuiyan; Wang Xiaoying; Li Xinmin; Guo Xuemei; Wu Lebin; Jiang Xuexiang

    2010-01-01

    .0% (78/100) respectively; those of maximum positive voxel ratio >0.519 were 88.7% (47/53), 61.7% (29/47), 72.3% (47/65), 82.9% (29/35), 76.0% (76/100) respectively; those of mean positive voxel ratio >0.519 were 62.3% (33/53), 85.1% (40/47), 82.5% (33/40), 66.7% (40/60), 73.0% (73/100) respectively; the consistency between mean (Cho + Cr)/Cit ratio and mean positive voxel ratio was fairly high (Kappa =0.818). Conclusion: Single voxel criteria were suggested to diagnose clinically suspected prostate cancer. Maximum positive voxel ration criteria were suggested to guide localization in biopsy. (authors)

  3. Multiparametric MRI of prostate cancer: an update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer.

    Science.gov (United States)

    Hegde, John V; Mulkern, Robert V; Panych, Lawrence P; Fennessy, Fiona M; Fedorov, Andriy; Maier, Stephan E; Tempany, Clare M C

    2013-05-01

    Magnetic resonance (MR) examinations of men with prostate cancer are most commonly performed for detecting, characterizing, and staging the extent of disease to best determine diagnostic or treatment strategies, which range from biopsy guidance to active surveillance to radical prostatectomy. Given both the exam's importance to individual treatment plans and the time constraints present for its operation at most institutions, it is essential to perform the study effectively and efficiently. This article reviews the most commonly employed modern techniques for prostate cancer MR examinations, exploring the relevant signal characteristics from the different methods discussed and relating them to intrinsic prostate tissue properties. Also, a review of recent articles using these methods to enhance clinical interpretation and assess clinical performance is provided. J. Magn. Reson. Imaging 2013;37:1035-1054. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  4. Correlation of endorectal coil magnetic resonance, transrectal ultrasound and radical prostatectomy findings in assessing extent of prostate cancer in referred urology patients

    International Nuclear Information System (INIS)

    Lavoipierre, A.; Little, A.F.; Greive, K.A.; Royce, P.L.; Snow, R.M.; Frydenberg, M.

    2002-01-01

    Full text: The aim of this study was to compare findings at prostate MR to ultrasound findings and pathology specimens in patients who subsequently underwent radical prostatectomy. Of the 61 patients who underwent composite MR prostate imaging, 39 patients with elevated PSA levels and / or abnormal DRE findings were found to have cancer on transrectal ultrasound (TRUS) and biopsy (random sextant and targeted biopsies). MRI was performed using composite phased array and endorectal coils, using axial T1 and axial, coronal and sagittal T2 weighted images through the prostate, together with axial T1 weighted imaging through the pelvis. Fifteen patients out the 39 patients with documented cancer then underwent radical prostatectomy. The resected specimen pathology was then compared with the MR and TRUS findings. Comparison of findings at MRI with those at prostatectomy indicated approximately 82.4% correlation comparing right side and left side disease (TRUS = 80%). There was a 13.3% false positive for seminal vesicle involvement on MR (TRUS = 0%) and a 10% false negative rate on MR (TRUS 10%) compared with pathology specimens.There was a 26.7% false positive rate of extracapsular extension on MR (TRUS = 0%) and a 6.6% false negative rate on MR (TRUS = 20%) compared with the pathology specimens. Of the 39 patients who had undergone TRUS and biopsy, the disease appeared more extensive on MRI than suspected at ultrasound in 14/39 (35.9%). High resolution MR imaging of the prostate is an acceptable method for assessing the presence of prostate cancer. However, our early experience, in this small series, suggests that there is a high mis-staging of disease on MR as is the case with TRUS, although MR is better than TRUS. The results underscore the need for additional assessment with MR spectroscopy. Copyright (2002) Blackwell Science Pty Ltd

  5. The effectivity of periprostatic nerve blockade for the pain control during transrectal ultrasound guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    Alper Otunctemur

    2013-06-01

    Full Text Available Aim: Transrectal ultrasound (TRUS guided prostete biopsy is accepted as a standard procedure in the diagnosis of prostate cancer. Many different protocoles are applied to reduce the pain during the process. In this study we aimed to the comparison of two procedure with intrarectal lidocaine gel and periprostatice nerve blockade respective- ly in addition to perianal intrarectal lidocaine gel on the pain control in prostate biop- sy by TRUS. Methods: 473 patients who underwent prostate biopsy guided TRUS between 2008-2012 were included in the study. 10-point linear visual analog pain scale(VAS was used to evaluate the pain during biopsy. The patients were divided into two groups according to anesthesia procedure. In Group 1, there were 159 patients who had perianal-intrarectal lidocaine gel, in Group 2 there were 314 patients who had periprostatic nerve blockade in addition to intrarectal lidocain gel. The pain about probe manipulation was aseesed by VAS-1 and during the biopsy needle entries was evalu- ated by VAS-2. Results were compared with Mann-Whitney U and Pearson chi-square test. Results: Mean VAS-2 scores in Group 1 and Group 2 were 4.54 ± 1.02 and 2.06 ± 0.79 respectively. The pain score was determined significantly lower in the Group 2 (p = 0.001. In both groups there was no significant difference in VAS-1 scores, patient’s age, prostate volume, complication rate and PSA level. Conclusion: The combination of periprostatic nerve blockade and intrarectal lidocain gel provides a more meaningful pain relief compared to group of patients undergoing intrarectal lidocaine gel.

  6. Effects of a psychosocial intervention on survival among patients with stage I breast and prostate cancer: a matched case-control study.

    Science.gov (United States)

    Shrock, D; Palmer, R F; Taylor, B

    1999-05-01

    Psychosocial factors have been linked to the development and progression of cancer and shown to be relevant in cancer care. However, the evidence that psychosocial interventions affect cancer survival is less conclusive. Few methodologically sound studies have addressed this issue. To investigate the effects of a 6-week psychosocial intervention on survival among patients with stage I breast and prostate cancer. Matched case-control. 3 rural hospitals or cancer centers in central Pennsylvania. 21 breast and 29 prostate stage I cancer patients (treatment group) matched with 74 breast and 65 prostate stage I cancer patients from the same hospitals who did not receive the intervention (control group). Six 2-hour health psychology classes conducted by a licensed staff psychologist. Survival time was compared between the 2 groups and with national norms. The intervention group lived significantly longer than did matched controls. At 4- to 7-year follow-up (median = 4.2 years), none of the breast cancer patients in the intervention group died, whereas 12% of those in the control group died. Twice as many matched-control prostate cancer patients died compared with those in the intervention group (28% vs 14%). Control group survival was similar to national norms. These results are consistent with prior clinical trials and suggest that short-term psychosocial interventions that encourage the expression of emotions, provide social support, and teach coping skills can influence survival among cancer patients. However, self-selection bias cannot be ruled out as an alternative explanation for the results. These interventions merit further consideration and research.

  7. 3D versus 2D Systematic Transrectal Ultrasound-Guided Prostate Biopsy: Higher Cancer Detection Rate in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Alexandre Peltier

    2013-01-01

    Full Text Available Objectives. To compare prostate cancer detection rates of extended 2D versus 3D biopsies and to further assess the clinical impact of this method in day-to-day practice. Methods. We analyzed the data of a cohort of 220 consecutive patients with no prior history of prostate cancer who underwent an initial prostate biopsy in daily practice due to an abnormal PSA and/or DRE using, respectively, the classical 2D and the new 3D systems. All the biopsies were done by a single experienced operator using the same standardized protocol. Results. There was no significant difference in terms of age, total PSA, or prostate volume between the two groups. However, cancer detection rate was significantly higher using the 3D versus the 2D system, 50% versus 34% (P<0.05. There was no statistically significant difference while comparing the 2 groups in term of nonsignificant cancer detection. Conclusion. There is reasonable evidence demonstrating the superiority of the 3D-guided biopsies in detecting prostate cancers that would have been missed using the 2D extended protocol.

  8. Intramuscular diclofenac vs periprostatic lidocaine injection for controlling pain undergoing transrectal ultrasound guided prostatic biopsy

    International Nuclear Information System (INIS)

    Alam, S.I.

    2017-01-01

    Background: Transrectal ultrasound (TRUS) technique for getting prostatic tissue for histopathology is now the standard procedure for malignant lesions of the prostate and imperative diagnostic investigation of patients with clinical specks of prostatic neoplasia. During TRUS guided biopsy, pain control has been important issue therefore, highly potent analgesia before this procedure should be considered on high priority according to current census. Therefore, we compared intramuscular diclofenac injection with sensory blockade of injection lidocaine to abolish pain undergoing prostatic biopsy with TRUS technique. Methods: Total 200 patients were selected for this study having raised PSA values and suspicious nodule on Digital Rectal Examination. These patients were segregated into two groups by randomization. Group Ar eceived intramuscular diclofenac and group Bw ere infiltrated with lidocaine injection for sensory blockade. Results: Patients in group A was having mean age of 64.5±5.8 years while for group B patients was 65.6±4.9 years (p=0.16). Both groups have statistically insignificant difference in their mean PSA values (p=0.24) and mean prostatic volume (p=0.22). The mean pain scores on visual analogue scale in groups A was 3.5±0.8 and in group B it was 2.4±0.8 (p<0.001). 60% group A patients reported with mild or no pain compared to 90% in group B. (p<0.001). Conclusion: Local blockade with lidocaine injection has better pain control as compared to patients experienced pain with intramuscular diclofenac used for prostatic biopsy through TRUS technique.

  9. MRI of the Prostate

    Science.gov (United States)

    ... be present in your body due to prior accidents. Foreign bodies near and especially lodged in the ... hyperplasia and infection. MR spectroscopy can examine the chemical makeup of the prostate ... charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  10. Diffusion-weighted MRI of the prostate

    International Nuclear Information System (INIS)

    Mueller-Lisse, U.G.; Scherr, M.K.; Mueller-Lisse, U.L.; Zamecnik, P.; Schlemmer, H.P.W.

    2011-01-01

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [de

  11. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  12. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  13. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  14. Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT.

    Science.gov (United States)

    Thomas, David H; Santhanam, Anand; Kishan, Amar U; Cao, Minsong; Lamb, James; Min, Yugang; O'Connell, Dylan; Yang, Yingli; Agazaryan, Nzhde; Lee, Percy; Low, Daniel

    2018-02-01

    To evaluate variations in intra- and interfractional tumour motion, and the effect on internal target volume (ITV) contour accuracy, using deformable image registration of real-time two-dimensional-sagittal cine-mode MRI acquired during lung stereotactic body radiation therapy (SBRT) treatments. Five lung tumour patients underwent free-breathing SBRT treatments on the ViewRay system, with dose prescribed to a planning target volume (defined as a 3-6 mm expansion of the 4DCT-ITV). Sagittal slice cine-MR images (3.5 × 3.5 mm 2 pixels) were acquired through the centre of the tumour at 4 frames per second throughout the treatments (3-4 fractions of 21-32 min). Tumour gross tumour volumes (GTVs) were contoured on the first frame of the MR cine and tracked for the first 20 min of each treatment using offline optical-flow based deformable registration implemented on a GPU cluster. A ground truth ITV (MR-ITV 20 min ) was formed by taking the union of tracked GTV contours. Pseudo-ITVs were generated from unions of the GTV contours tracked over 10 s segments of image data (MR-ITV 10 s ). Differences were observed in the magnitude of median tumour displacement between days of treatments. MR-ITV 10 s areas were as small as 46% of the MR-ITV 20 min . An ITV offers a "snapshot" of breathing motion for the brief period of time the tumour is imaged on a specific day. Real-time MRI over prolonged periods of time and over multiple treatment fractions shows that ITV size varies. Further work is required to investigate the dosimetric effect of these results. Advances in knowledge: Five lung tumour patients underwent free-breathing MRI-guided SBRT treatments, and their tumours tracked using deformable registration of cine-mode MRI. The results indicate that variability of both intra- and interfractional breathing amplitude should be taken into account during planning of lung radiotherapy.

  15. Diagnostic usefulness of endorectal magnetic resonance imaging with dynamic contrast-enhancement in patients with localized prostate cancer. Mapping studies with biopsy specimens

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Samma, Shoji; Joko, Masanori; Akiyama, Tatsuya; Takewa, Megumi; Kitano, Satoru; Okajima, Eigoro

    1999-01-01

    New diagnostic criteria for dynamic magnetic resonance (MR) imaging in prostate cancer are presented. The diagnostic usefulness of endorectal MR imaging with dynamic contrast-enhancement in localized prostate cancer and the validity of these criteria were evaluated. Eighteen untreated patients who were suspected of localized prostate cancer were included in the study. They received endorectal dynamic MR imaging before systematic sextant needle biopsy. First, a mapping study with the findings of MR images and histopathology of biopsy specimens was performed in eight patients out of 18 to compare the difference in T2-weighted images with the endorectal coil and the body coil in the same individuals. Second, another mapping study was performed in all 18 patients by analyzing the findings of endorectal dynamic MR images. For the diagnosis of prostate cancer in MR imaging, we offered diagnostic criteria from our experience in addition to those in plain T2-weighted images from the literature. The overall diagnostic rates of endorectal dynamic MR imaging were 88.9% in accuracy, 100% in sensitivity, and 81.8% in specificity. In the comparison of the endorectal and body coils in T2-weighted images in eight patients, there was no difference in the diagnostic rates except for one more histopathologic false positive portion in endorectal MR imaging. In the second mapping study in 18 patients, the diagnostic rates were 92.6% in accuracy, 88.9% in sensitivity and 93.3% in specificity. Endorectal dynamic imaging raised the diagnostic sensitivity from 77.8 to 88.9%. The data demonstrated the validity of this diagnostic criteria and the diagnostic usefulness of endorectal dynamic MR imaging in localized prostate cancer. (author)

  16. Magnetic Resonance–Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation

    International Nuclear Information System (INIS)

    Chu, William; Staruch, Robert M.; Pichardo, Samuel; Tillander, Matti; Köhler, Max O.; Huang, Yuexi; Ylihautala, Mika; McGuffin, Merrylee; Czarnota, Gregory; Hynynen, Kullervo

    2016-01-01

    Purpose: To evaluate the feasibility of magnetic resonance–guided high-intensity focused ultrasound (MR-HIFU) mild hyperthermia in deep tissue targets for enhancing radiation therapy and chemotherapy in the context of recurrent rectal cancer. A preclinical study was performed to evaluate the safety and performance of MR-HIFU mild hyperthermia. A prospective imaging study was performed in volunteers with rectal cancer to evaluate MR thermometry quality near the rectum and accessibility of rectal tumors using MR-HIFU. Methods and Materials: Mild hyperthermia was performed in pig thigh (9 sonications, 6 pigs) using a clinical MR-HIFU system. Targets near the rectal wall and deep thigh were evaluated. Thermal maps obtained in 6 planes every 3.2 seconds were used to control sonications in 18-mm diameter treatment regions at temperatures of 42°C to 42.5°C for 10 to 60 minutes. Volunteer imaging-only studies to assess the quality of MR thermometry (without heating) were approved by the institutional research ethics board. Anatomic and MR thermometry images were acquired in consenting volunteers with rectal cancer. In 3 of 6 study participants, rectal filling with saline was used to reduce motion-related MR thermometry artifacts near the tumor. Results: In pigs, mean target temperature matched the desired hyperthermia temperature within 0.2°C; temporal standard deviation ≤0.5°C. With optimized control thresholds, no undesired tissue damage was observed. In human volunteers, MR temperature measurements had adequate precision and stability, especially when rectal filling was used to reduce bowel motion. Conclusions: In pigs, MR-HIFU can safely deliver mild hyperthermia (41°C-43°C) to a targeted volume for 30 minutes. In humans, careful patient selection and preparation will enable adequate targeting for recurrent rectal cancers and sufficient MR temperature mapping stability to control mild hyperthermia. These results enable human trials of MR-HIFU hyperthermia.

  17. Magnetic Resonance–Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation

    Energy Technology Data Exchange (ETDEWEB)

    Chu, William, E-mail: William.Chu@sunnybrook.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre and the University of Toronto, Toronto, Ontario (Canada); Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario (Canada); Staruch, Robert M. [Clinical Sites Research Program, Philips Research, Cambridge, Massachusetts (United States); Pichardo, Samuel [Thunder Bay Regional Research Institute, Thunder Bay, Ontario (Canada); Physics and Electrical Engineering, Lakehead University, Thunder Bay, Ontario (Canada); Tillander, Matti; Köhler, Max O. [MR Therapy, Philips Healthcare, Vantaa (Finland); Huang, Yuexi [Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario (Canada); Ylihautala, Mika [MR Therapy, Philips Healthcare, Vantaa (Finland); McGuffin, Merrylee [Department of Radiation Oncology, Sunnybrook Health Sciences Centre and the University of Toronto, Toronto, Ontario (Canada); Czarnota, Gregory [Department of Radiation Oncology, Sunnybrook Health Sciences Centre and the University of Toronto, Toronto, Ontario (Canada); Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario (Canada); Hynynen, Kullervo [Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario (Canada)

    2016-07-15

    Purpose: To evaluate the feasibility of magnetic resonance–guided high-intensity focused ultrasound (MR-HIFU) mild hyperthermia in deep tissue targets for enhancing radiation therapy and chemotherapy in the context of recurrent rectal cancer. A preclinical study was performed to evaluate the safety and performance of MR-HIFU mild hyperthermia. A prospective imaging study was performed in volunteers with rectal cancer to evaluate MR thermometry quality near the rectum and accessibility of rectal tumors using MR-HIFU. Methods and Materials: Mild hyperthermia was performed in pig thigh (9 sonications, 6 pigs) using a clinical MR-HIFU system. Targets near the rectal wall and deep thigh were evaluated. Thermal maps obtained in 6 planes every 3.2 seconds were used to control sonications in 18-mm diameter treatment regions at temperatures of 42°C to 42.5°C for 10 to 60 minutes. Volunteer imaging-only studies to assess the quality of MR thermometry (without heating) were approved by the institutional research ethics board. Anatomic and MR thermometry images were acquired in consenting volunteers with rectal cancer. In 3 of 6 study participants, rectal filling with saline was used to reduce motion-related MR thermometry artifacts near the tumor. Results: In pigs, mean target temperature matched the desired hyperthermia temperature within 0.2°C; temporal standard deviation ≤0.5°C. With optimized control thresholds, no undesired tissue damage was observed. In human volunteers, MR temperature measurements had adequate precision and stability, especially when rectal filling was used to reduce bowel motion. Conclusions: In pigs, MR-HIFU can safely deliver mild hyperthermia (41°C-43°C) to a targeted volume for 30 minutes. In humans, careful patient selection and preparation will enable adequate targeting for recurrent rectal cancers and sufficient MR temperature mapping stability to control mild hyperthermia. These results enable human trials of MR-HIFU hyperthermia.

  18. Can pre-operative contrast-enhanced dynamic MR imaging for prostate cancer predict microvessel density in prostatectomy specimens?

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Department of Diagnostic Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076, Tuebingen (Germany); Merkle, Jonas; Kaick, Gerhard van [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Grobholz, Rainer [Department of Pathology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Jaeger, Tim; Michel, Maurice Stephan [Department of Urology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Werner, Axel; Rabe, Jan [Department of Diagnostic Radiology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany)

    2004-02-01

    The aim of this study was to correlate quantitative dynamic contrast-enhanced MRI (DCE MRI) parameters with microvessel density (MVD) in prostate carcinoma. Twenty-eight patients with biopsy-proven prostate carcinoma were examined by endorectal MRI including multiplanar T2- and T1-weighted spin-echo and dynamic T1-weighted turbo-FLASH MRI during and after intravenous Gd-DTPA administration. Microvessels were stained on surgical specimens using a CD31 monoclonal antibody. The MVD was quantified in hot spots by counting (MVC) and determining the area fraction by morphometry (MVAF). The DCE MRI data were analyzed using an open pharmacokinetic two-compartment model. In corresponding anatomic locations the time shift ({delta}t) between the beginning of signal enhancement of cancer and adjacent normal prostatic tissue, the degree of contrast enhancement and the contrast exchange rate constant (k{sub 21}) were calculated. The MVC and MVAF were elevated in carcinoma (p<0.001 and p=0.002, respectively) and correlated to k{sub 21} (r=0.62, p<0.001 and r=0.80, p<0.001, respectively). k{sub 21}-values of carcinoma were significantly higher compared with normal peripheral but not central zone tissue. {delta}t was longer in high compared with low-grade tumors (p=0.025). The DCE MRI can provide important information about individual MVD in prostate cancer, which may be helpful for guiding biopsy and assessing individual prognosis. (orig.)

  19. Magnetic resonance only workflow and validation of dose calculations for radiotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Lübeck Christiansen, Rasmus; Jensen, Henrik R.; Brink, Carsten

    2017-01-01

    Background: Current state of the art radiotherapy planning of prostate cancer utilises magnetic resonance (MR) for soft tissue delineation and computed tomography (CT) to provide an electron density map for dose calculation. This dual scan workflow is prone to setup and registration error....... This study evaluates the feasibility of an MR-only workflow and the validity of dose calculation from an MR derived pseudo CT. Material and methods: Thirty prostate cancer patients were CT and MR scanned. Clinical treatment plans were generated on CT using a single 18 MV arc volumetric modulated arc therapy...... was successfully delivered to one patient, including manually performed daily IGRT. Conclusions: Median gamma pass rates were high for pseudo CT and proved superior to uniform density. Local differences in dose calculations were concluded not to have clinical relevance. Feasibility of the MR-only workflow...

  20. [Interest using 3D ultrasound and MRI fusion biopsy for prostate cancer detection].

    Science.gov (United States)

    Marien, A; De Castro Abreu, A; Gill, I; Villers, A; Ukimura, O

    2017-09-01

    The strategic therapy for prostate cancer depends on histo-pronostics data, which could be upgraded by obtaining targeted biopsies (TB) with MRI (magnetic resonance imagery) fusion 3D ultrasound. To compare diagnostic yield of image fusion guided prostate biopsy using image fusion of multi-parametric MRI (mpMRI) with 3D-TRUS. Between January 2010 and April 2013, 179 consecutive patients underwent outpatient TRUS biopsy using the real-time 3D TRUS tracking system (Urostation™). These patients underwent MRI-TRUS fusion targeted biopsies (TB) with 3D volume data of the MRI elastically fused with 3D TRUS at the time of biopsy. A hundred and seventy-three patients had TBs with fusion. Mean biopsy core per patient were 11.1 (6-14) for SB and 2.4 (1-6) for TB. SBs were positive in 11% compared to 56% for TB (Pperform the higher level of MR/US fusion and should be use for active surveillance. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  2. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F.; Bretschneider, T.; Hartwig, T.; Disch, A.C.

    2014-01-01

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  3. Technique adaptation, strategic replanning, and team learning during implementation of MR-guided brachytherapy for cervical cancer.

    Science.gov (United States)

    Skliarenko, Julia; Carlone, Marco; Tanderup, Kari; Han, Kathy; Beiki-Ardakani, Akbar; Borg, Jette; Chan, Kitty; Croke, Jennifer; Rink, Alexandra; Simeonov, Anna; Ujaimi, Reem; Xie, Jason; Fyles, Anthony; Milosevic, Michael

    MR-guided brachytherapy (MRgBT) with interstitial needles is associated with improved outcomes in cervical cancer patients. However, there are implementation barriers, including magnetic resonance (MR) access, practitioner familiarity/comfort, and efficiency. This study explores a graded MRgBT implementation strategy that included the adaptive use of needles, strategic use of MR imaging/planning, and team learning. Twenty patients with cervical cancer were treated with high-dose-rate MRgBT (28 Gy in four fractions, two insertions, daily MR imaging/planning). A tandem/ring applicator alone was used for the first insertion in most patients. Needles were added for the second insertion based on evaluation of the initial dosimetry. An interdisciplinary expert team reviewed and discussed the MR images and treatment plans. Dosimetry-trigger technique adaptation with the addition of needles for the second insertion improved target coverage in all patients with suboptimal dosimetry initially without compromising organ-at-risk (OAR) sparing. Target and OAR planning objectives were achieved in most patients. There were small or no systematic differences in tumor or OAR dosimetry between imaging/planning once per insertion vs. daily and only small random variations. Peer review and discussion of images, contours, and plans promoted learning and process development. Technique adaptation based on the initial dosimetry is an efficient approach to implementing MRgBT while gaining comfort with the use of needles. MR imaging and planning once per insertion is safe in most patients as long as applicator shifts, and large anatomical changes are excluded. Team learning is essential to building individual and programmatic competencies. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Definition of the prostate in CT and MRI: a multi-observer study

    NARCIS (Netherlands)

    Rasch, C.; Barillot, I.; Remeijer, P.; Touw, A.; van Herk, M.; Lebesque, J. V.

    1999-01-01

    To determine, in three-dimensions, the difference between prostate delineation in magnetic resonance (MR) and computer tomography (CT) images for radiotherapy treatment planning. Three radiation oncologists, considered experts in the field, outlined the prostate without seminal vesicles both on CT,

  5. Multi-parametric MR imaging for prostate carcinoma; Multiparametrische MR-Bildgebung beim Prostatakarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Abt. Radiologie

    2017-03-15

    Multi-parametric NMR imaging in case of prostate carcinoma can improve diagnostics, allows reliable prognostic estimations and helps to find the optimum individual therapy. The contribution is focused to deliver the needed methodological tools and background knowledge for the daily routine.

  6. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    International Nuclear Information System (INIS)

    Davidson, J.; Jayaraman, S.

    2011-01-01

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  7. MR-guided noninvasive thermal coagulation of in-vivo liver tissue using ultrasonic phased array

    Science.gov (United States)

    Daum, Douglas R.; Smith, Nadine; McDannold, Nathan; Hynynen, Kullervo H.

    1999-05-01

    Magnetic resonance (MR) imaging was used to guide and monitor the thermal tissue coagulation of in vivo porcine tissue using a 256 element ultrasonic phased array. The array could coagulate tissue volumes greater than 2 cm3 in liver and 0.5 cm3 in kidney using a single 20 second sonication. This sonication used multiple focus fields which were temporally cycled to heat large tissue volumes simultaneously. Estimates of the coagulated tissue using a thermal dose threshold compare well with T2-weighted images of post sonication lesions. The overlapping large focal volumes could aid in the treatment of large tumor volumes which require multiple overlapping sonications. The ability of MR to detect the presence and undesirable thermal increases at acoustic obstacle such as cartilaginous and bony ribs is demonstrated. This could have a significant impact on the ability to monitor thermal treatments of the liver and other organs which are acoustically blocked.

  8. Potential of hybrid 18F-fluorocholine PET/MRI for prostate cancer imaging

    International Nuclear Information System (INIS)

    Perrot, Thomas de; Scheffler, Max; Vallee, Jean-Paul; Rager, Olivier; Ratib, Osman; Lord, Martin; Pusztaszeri, Marc; Iselin, Christophe

    2014-01-01

    To report the first results of hybrid 18 F-fluorocholine PET/MRI imaging for the detection of prostate cancer. This analysis included 26 consecutive patients scheduled for prostate PET/MRI before radical prostatectomy. The examinations were performed on a hybrid whole-body PET/MRI scanner. The MR acquisitions which included T2-weighted, diffusion-weighted and dynamic contrast-enhanced sequences were followed during the same session by whole-body PET scans. Parametric maps were constructed to measure normalized T2-weighted intensity (nT2), apparent diffusion coefficient (ADC), volume transfer constant (K trans ), extravascular extracellular volume fraction (v e ) and standardized uptake values (SUV). With pathology as the gold standard, ROC curves were calculated using logistic regression for each parameter and for the best combination with and without PET to obtain a MR model versus a PETMR model. Of the 26 patients initially selected, 3 were excluded due to absence of an endorectal coil (2 patients) or prosthesis artefacts (1 patient). In the whole prostate, the area under the curve (AUC) for SUV max , ADC, nT2, K trans and v e were 0.762, 0.756, 0.685, 0.611 and 0.529 with a best threshold at 3.044 for SUV max and 1.075 x 10 -3 mm 2 /s for ADC. The anatomical distinction between the transition zone and the peripheral zone showed the potential of the adjunctive use of PET. In the peripheral zone, the AUC of 0.893 for the PETMR model was significantly greater (p = 0.0402) than the AUC of 0.84 for the MR model only. In the whole prostate, no relevant correlation was observed between ADC and SUV max . The SUV max was not affected by the Gleason score. The performance of a hybrid whole-body 18 F-fluorocholine PET/MRI scan in the same session combined with a prostatic MR examination did not interfere with the diagnostic accuracy of the MR sequences. The registration of the PET data and the T2 anatomical MR sequence data allowed precise localization of hypermetabolic

  9. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  10. Feasibility and acceptability of SMS text messaging in a prostate cancer educational intervention for African American men.

    Science.gov (United States)

    Le, Daisy; Holt, Cheryl L; Saunders, Darlene R; Wang, Min Qi; Coriolan, Annie; Savoy, Alma D; Slade, Jimmie L; Muwwakkil, Bettye; Atkinson, Nancy L

    2016-12-01

    African Americans' greater access to mobile phones makes short messaging service technology a promising complement to health promotion interventions. Short messaging service text messages were added to the Men's Prostate Awareness Church Training project, a men's health intervention for African American men. We report on the feasibility and acceptability of the use of short messaging service text messages in the intervention. Short messaging service text messages served as (1) workshop reminders; (2) post-workshop message reinforcement; (3) spiritual/motivational messages; and (4) participant retention. At workshop 4, over 65 percent of participants wished to continue receiving the messages. While there was an increase in recall over time, more than one-third of the participants did not recall receiving the 53 text messages. However, recall was considerably greater among men who attended the Men's Prostate Awareness Church Training workshops. Overall, the inclusion of text messages in health promotion interventions targeting mature African American men was found to be feasible and acceptable. © The Author(s) 2015.

  11. MR demonstration of a prostate gland in a female pseudohermaphrodite

    International Nuclear Information System (INIS)

    Subramanian, Subramanian; Gamanagatti, Shivanand; Sharma, Raju

    2006-01-01

    We present the rare case of a 14-year-old female pseudohermaphrodite due to congenital adrenal hyperplasia (CAH). MRI revealed the presence of a hypoplastic uterus, ovaries, clitoromegaly, and prostate gland with its typical zonal anatomy. Transrectal sonography also confirmed the presence of a prostate gland. (orig.)

  12. "Textural analysis of multiparametric MRI detects transition zone prostate cancer".

    Science.gov (United States)

    Sidhu, Harbir S; Benigno, Salvatore; Ganeshan, Balaji; Dikaios, Nikos; Johnston, Edward W; Allen, Clare; Kirkham, Alex; Groves, Ashley M; Ahmed, Hashim U; Emberton, Mark; Taylor, Stuart A; Halligan, Steve; Punwani, Shonit

    2017-06-01

    To evaluate multiparametric-MRI (mpMRI) derived histogram textural-analysis parameters for detection of transition zone (TZ) prostatic tumour. Sixty-seven consecutive men with suspected prostate cancer underwent 1.5T mpMRI prior to template-mapping-biopsy (TPM). Twenty-six men had 'significant' TZ tumour. Two radiologists in consensus matched TPM to the single axial slice best depicting tumour, or largest TZ diameter for those with benign histology, to define single-slice whole TZ-regions-of-interest (ROIs). Textural-parameter differences between single-slice whole TZ-ROI containing significant tumour versus benign/insignificant tumour were analysed using Mann Whitney U test. Diagnostic accuracy was assessed by receiver operating characteristic area under curve (ROC-AUC) analysis cross-validated with leave-one-out (LOO) analysis. ADC kurtosis was significantly lower (p Textural features of the whole prostate TZ can discriminate significant prostatic cancer through reduced kurtosis of the ADC-histogram where significant tumour is included in TZ-ROI and reduced T1 entropy independent of tumour inclusion. • MR textural features of prostate transition zone may discriminate significant prostatic cancer. • Transition zone (TZ) containing significant tumour demonstrates a less peaked ADC histogram. • TZ containing significant tumour reveals higher post-contrast T1-weighted homogeneity. • The utility of MR texture analysis in prostate cancer merits further investigation.

  13. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  14. MR-guided laser-induced thermotherapy (LITT) of liver metastases. Prospective results of an optimized method

    International Nuclear Information System (INIS)

    Vogl, T.J.; Mueller, P.; Hirsch, H.; Philipp, C.; Hammerstingl, R.; Boettcher, H.; Riess, H.; Beuthan, J.; Felix, R.

    1995-01-01

    In a prospective study MR-guided laser-induced thermotherapy (LITT) of liver metastases was optimized and the clinical parameters evaluated. Seventeen patients (4 women, 13 men) with a total of 29 lesions underwent LITT in 25 sessions through 1 March 1994. Twelve of them suffered from colorectal carcinomas, 5 from other primary tumors. Under local anesthesia a maximum of 5 lesions per patient were treated. For MR-guided LITT a neodymium yttrium aluminum garnet laser (Nd-YAG 1064 nm) with energy varying from 3 to 7.5 W was used. Energy and application time were defined through a computer program; they varied, dependent on the lesion size, location and consistency. To monitor the progress of LITT two special thermosensitive MR sequences (Thermo-Turbo-FLASH and FLASH-2D sequences) were individually optimized, whereby the increase in temperature correlates with an increase in signal loss. All procedures were well tolerated without significant early or late side effects. In only one patient was minimal air documentated in the pleural cavity with spontaneous resorption. Patients were dismissed without complaints after 24-h hospitalization. The control parameters of the contrast-enhanced dynamic MRI documented at optimal response a hypointense signal around the tip of the laser applicator, in accordance with laser-induced necrosis. In lesions 20 mm or smaller, nearly 100% tumor necrosis was achieved and in lesions larger than 20 mm, only 50%. Follow-up evaluation 6 months after treaqtment shows a significantly better response in lesions with a diameter fo 20 mm or smaller, with a local tumor control rate of 66%. In lesions larger than 20 mm only a local tumor control rate of 35% could be achieved. (orig./MG) [de

  15. Feasibility of MR-only proton dose calculations for prostate cancer radiotherapy using a commercial pseudo-CT generation method

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Landry, Guillaume; Belka, Claus; Parodi, Katia; Seevinck, Peter R.; Raaymakers, Bas W.; Kurz, Christopher

    2017-12-01

    A magnetic resonance (MR)-only radiotherapy workflow can reduce cost, radiation exposure and uncertainties introduced by CT-MRI registration. A crucial prerequisite is generating the so called pseudo-CT (pCT) images for accurate dose calculation and planning. Many pCT generation methods have been proposed in the scope of photon radiotherapy. This work aims at verifying for the first time whether a commercially available photon-oriented pCT generation method can be employed for accurate intensity-modulated proton therapy (IMPT) dose calculation. A retrospective study was conducted on ten prostate cancer patients. For pCT generation from MR images, a commercial solution for creating bulk-assigned pCTs, called MR for Attenuation Correction (MRCAT), was employed. The assigned pseudo-Hounsfield Unit (HU) values were adapted to yield an increased agreement to the reference CT in terms of proton range. Internal air cavities were copied from the CT to minimise inter-scan differences. CT- and MRCAT-based dose calculations for opposing beam IMPT plans were compared by gamma analysis and evaluation of clinically relevant target and organ at risk dose volume histogram (DVH) parameters. The proton range in beam’s eye view (BEV) was compared using single field uniform dose (SFUD) plans. On average, a (2%, 2 mm) gamma pass rate of 98.4% was obtained using a 10% dose threshold after adaptation of the pseudo-HU values. Mean differences between CT- and MRCAT-based dose in the DVH parameters were below 1 Gy (radiotherapy, is feasible following adaptation of the assigned pseudo-HU values.

  16. Prostatic intraepithelial neoplasia-like ductal prostatic adenocarcinoma: A case suitable for active surveillance?

    Directory of Open Access Journals (Sweden)

    Soroush Rais-Bahrami

    2017-01-01

    Full Text Available In contrast to typical prostatic ductal adenocarcinoma, prostatic intraepithelial neoplasia (PIN-like ductal adenocarcinoma is a rare variant of prostate cancer with low-grade clinical behavior. We report a case of a 66-year-old African-American male with an elevated serum prostate-specific antigen who underwent multiparametric prostate magnetic resonance imaging (MRI and MRI/ultrasound fusion-guided biopsies. Pathology demonstrated low-volume Gleason score 3 + 3 = 6 (Grade Group 1, acinar adenocarcinoma involving one core and PIN-like ductal adenocarcinoma on a separate core. Herein, we discuss the potential role of active surveillance for patients with this rare variant of prostate cancer found in the era of advanced imaging with multiparametric MRI for prostate cancer.

  17. Malignant paraganglioma of the prostate: case report, depiction by meta-iodobenzylguanidine scintigraphy and review of the literature

    International Nuclear Information System (INIS)

    Shapiro, B.; Gonzalez, E.; Weissman, A.; Ann Arbor, Univ. of Michigan; McHugh, T.; Markel, S.F.

    1997-01-01

    Objective: to describe the 123-I-MIBG scintigraphic, CT, MRI, operative and pathological findings in a case of malignant prostatic paraganglioma and to review the literature on this very rare tumor. Experimental design: clinical imaging and pathological correlation of data in a referred patient. Setting: regional referral center and tertiary referral academic medical center. Patient: 17 year old man presenting with painless hematuria and a large prostatic mass. Interventions and measures: renal ultrasound, transrectal ultrasound, ultrasound guided prostatic biopsy, pelvic CT and MRI, planar and SPECT 123-I-MIBG scintigraphy, and surgical exploration. Results: the patient had a significant hydronephrosis of the left kidney and marked enlargement (120 ml) of the prostate gland by ultrasound. Ultrasound guided biopsies of the prostate and a left pelvic lymph node revealed a neuroendocrine tumor staining positive for chromogranin. CT and MRI revealed a large tumor of the prostate invading the seminal vesicles, bladder and rectum with extensive pelvic lymph node spread. The primary tumor and one of the nodes were shown to be 123-I-MIBG avid confirming the neuroendocrine nature of the tumor. The lesion was unresponsive to chemotherapy and unresectable at surgical exploration. Conclusions: today there have only been 5 reports of prostatic paragangliomas. To our knowledge this is the first to have been studied by MIBG scintigraphy and like most paragangliomas it was MIBG-avid

  18. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Michael C.; Atwell, Thomas D.; King, Bernard F.; Welch, Timothy; Goenka, Ajit H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mynderse, Lance A. [Mayo Clinic, Department of Urology, Rochester, MN (United States)

    2017-08-15

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. (orig.)

  19. Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: A deformable registration and validation study

    International Nuclear Information System (INIS)

    Lian, J.; Xing, L.; Hunjan, S.; Dumoulin, C.; Levin, J.; Lo, A.; Watkins, R.; Rohling, K.; Giaquinto, R.; Kim, D.; Spielman, D.; Daniel, B.

    2004-01-01

    The endorectal coil is being increasingly used in magnetic resonance imaging (MRI) and MR spectroscopic imaging (MRSI) to obtain anatomic and metabolic images of the prostate with high signal-to-noise ratio (SNR). In practice, however, the use of endorectal probe inevitably distorts the prostate and other soft tissue organs, making the analysis and the use of the acquired image data in treatment planning difficult. The purpose of this work is to develop a deformable image registration algorithm to map the MRI/MRSI information obtained using an endorectal probe onto CT images and to verify the accuracy of the registration by phantom and patient studies. A mapping procedure involved using a thin plate spline (TPS) transformation was implemented to establish voxel-to-voxel correspondence between a reference image and a floating image with deformation. An elastic phantom with a number of implanted fiducial markers was designed for the validation of the quality of the registration. Radiographic images of the phantom were obtained before and after a series of intentionally introduced distortions. After mapping the distorted phantom to the original one, the displacements of the implanted markers were measured with respect to their ideal positions and the mean error was calculated. In patient studies, CT images of three prostate patients were acquired, followed by 3 Tesla (3 T) MR images with a rigid endorectal coil. Registration quality was estimated by the centroid position displacement and image coincidence index (CI). Phantom and patient studies show that TPS-based registration has achieved significantly higher accuracy than the previously reported method based on a rigid-body transformation and scaling. The technique should be useful to map the MR spectroscopic dataset acquired with ER probe onto the treatment planning CT dataset to guide radiotherapy planning

  20. Prostate bed motion may cause geographic miss in post-prostatectomy image-guided intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Bell, Linda J.; Cox, Jennifer; Eade, Thomas; Rinks, Marianne; Kneebone, Andrew

    2013-01-01

    There is little data to guide radiation oncologists on appropriate margin selection in the post-prostatectomy setting. The aim of this study was to quantify interfraction variation in motion of the prostate bed to determine these margins. The superior and inferior surgical clips in the prostate bed were tracked on pretreatment cone beam CT images (n=377) for 40 patients who had received post-prostatectomy radiotherapy. Prostate bed motion was calculated for the upper and lower segments by measuring the position of surgical clips located close to midline relative to bony anatomy in the axial (translational) and sagittal (tilt) planes. The frequency of potential geographic misses was calculated for either 1cm or 0.5cm posterior planning target volume margins. The mean magnitude of movement of the prostate bed in the anterior–posterior, superior–inferior and left–right planes, respectively, were as follows: upper portion, 0.50cm, 0.28cm, 0.10cm; lower portion, 0.18cm, 0.18cm, 0.08cm. The random and systematic errors, respectively, of the prostate bed motion in the anterior–posterior, superior–inferior and left–right planes, respectively, were as follows: upper portion, 0.47cm and 0.50cm, 0.28cm and 0.27cm, 0.11cm and 0.11cm; lower portion, 0.17cm and 18cm, 0.17cm and 0.19cm, 0.08cm and 0.10cm. Most geographic misses occurred in the upper prostate bed in the anterior–posterior plane. The median prostate bed tilt was 1.8° (range −23.4° to 42.3°). Variability was seen in all planes for the movement of both surgical clips. The greatest movement occurred in the anterior–posterior plane in the upper prostate bed, which could cause geographic miss of treatment delivery. The variability in the movement of the superior and inferior clips indicates a prostate bed tilt that would be difficult to correct with standard online matching techniques. This creates a strong argument for using anisotropic planning target volume margins in post