WorldWideScience

Sample records for monoxide rebreathing method

  1. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  2. Altitude training and haemoglobin mass from the optimised carbon monoxide rebreathing method determined by a meta-analysis.

    Science.gov (United States)

    Gore, Christopher J; Sharpe, Ken; Garvican-Lewis, Laura A; Saunders, Philo U; Humberstone, Clare E; Robertson, Eileen Y; Wachsmuth, Nadine B; Clark, Sally A; McLean, Blake D; Friedmann-Bette, Birgit; Neya, Mitsuo; Pottgiesser, Torben; Schumacher, Yorck O; Schmidt, Walter F

    2013-12-01

    To characterise the time course of changes in haemoglobin mass (Hbmass) in response to altitude exposure. This meta-analysis uses raw data from 17 studies that used carbon monoxide rebreathing to determine Hbmass prealtitude, during altitude and postaltitude. Seven studies were classic altitude training, eight were live high train low (LHTL) and two mixed classic and LHTL. Separate linear-mixed models were fitted to the data from the 17 studies and the resultant estimates of the effects of altitude used in a random effects meta-analysis to obtain an overall estimate of the effect of altitude, with separate analyses during altitude and postaltitude. In addition, within-subject differences from the prealtitude phase for altitude participant and all the data on control participants were used to estimate the analytical SD. The 'true' between-subject response to altitude was estimated from the within-subject differences on altitude participants, between the prealtitude and during-altitude phases, together with the estimated analytical SD. During-altitude Hbmass was estimated to increase by ∼1.1%/100 h for LHTL and classic altitude. Postaltitude Hbmass was estimated to be 3.3% higher than prealtitude values for up to 20 days. The within-subject SD was constant at ∼2% for up to 7 days between observations, indicative of analytical error. A 95% prediction interval for the 'true' response of an athlete exposed to 300 h of altitude was estimated to be 1.1-6%. Camps as short as 2 weeks of classic and LHTL altitude will quite likely increase Hbmass and most athletes can expect benefit.

  3. CORP

    DEFF Research Database (Denmark)

    Siebenmann, Christoph; Keiser, Stefanie; Robach, Paul

    2017-01-01

    In this Cores of Reproducibility in Physiology (CORP) article, we present the theory and practical aspects of the carbon monoxide (CO) rebreathing method for the determination of total hemoglobin mass in humans. With CO rebreathing, a small quantity of CO is diluted in O2 and rebreathed for a spe......In this Cores of Reproducibility in Physiology (CORP) article, we present the theory and practical aspects of the carbon monoxide (CO) rebreathing method for the determination of total hemoglobin mass in humans. With CO rebreathing, a small quantity of CO is diluted in O2 and rebreathed...

  4. The value of closed-circuit rebreathers for biological research

    Science.gov (United States)

    Pyle, Richrad L.; Lobel, Phillip S.; Tomoleoni, Joseph

    2016-01-01

    Closed-circuit rebreathers have been used for underwater biological research since the late 1960s, but have only started to gain broader application within scientific diving organizations within the past two decades. Rebreathers offer certain specific advantages for such research, especially for research involving behavior and surveys that depend on unobtrusive observers or for a stealthy approach to wildlife for capture and tagging, research that benefits from extended durations underwater, and operations requiring access to relatively deep (>50 m) environments (especially in remote locations). Although many institutions have been slow to adopt rebreather technology within their diving programs, recent developments in rebreather technology that improve safety, standardize training requirements, and reduce costs of equipment and maintenance, will likely result in a trend of increasing utilization of rebreathers for underwater biological research.

  5. Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow

    DEFF Research Database (Denmark)

    Christensen, P; Clemensen, P; Andersen, P K

    2000-01-01

    To compare measurements of the effective pulmonary blood flow (Qep, i.e., nonshunted fraction of cardiac output, Qt) by the inert gas rebreathing (RB) method and the thermodilution (TD) technique in critically ill patients.......To compare measurements of the effective pulmonary blood flow (Qep, i.e., nonshunted fraction of cardiac output, Qt) by the inert gas rebreathing (RB) method and the thermodilution (TD) technique in critically ill patients....

  6. Comparison of total haemoglobin mass measured with the optimized carbon monoxide rebreathing method across different Radiometer™ ABL-80 and OSM-3 hemoximeters

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M

    2014-01-01

    A new Radiometer™ hemoximeter (ABL-80) has recently become available to measure carboxyhaemoglobin concentration for the optimized CO-rebreathing method (oCOR-method). Within the English Institute of Sport (EIS), hemoximeters are used in three different laboratories; therefore, precision and agreement of total haemoglobin mass (tHbmass) determination across sites is essential, and comparison to the previous model OSM-3 is desirable. Six male and one female (age 30  ±  6 years, body mass 78.1  ±  10.6 kg) undertook the oCOR-method. Venous blood (∼2 ml) was sampled immediately before and at 7 min during the oCOR-method; with seven replicates from each time point simultaneously analysed on five different Radiometer™ hemoximeters [OSM-3(1), OSM-3(2), ABL-80(1), ABL-80(2) and ABL-80(3)]. There were no differences (p > 0.05) between Δ%HbCO or mean tHbmass analysed with five different hemoximeters (OSM-3(1): 886  ±  167 g; OSM-3(2): 896  ±  160 g: ABL-80(1): 904  ±  157 g; ABL-80(2): 906  ±  163 g: ABL-80(3): 906  ±  162 g). However, the Bland–Altman plot revealed that there was closer agreement between ABL-80 machines for tHbmass than for the OSM-3. The variance (i.e. % error) across replicate samples decreased as the number of samples increased, with the error derived from the ‘worse-case’ scenario (single samples) being 1.2 to 1.6 fold greater in the OSM-3 than the ABL-80. Although there were no differences in the average tHbmass measured with five different hemoximeters, the new ABL-80 were in better agreement with each other compared to the old OSM-3. Previously, five replicates were required to achieve a low error using the OSM-3; however, three replicates are sufficient with the ABL-80 model to produce an error of ≤ 1% in tHbmass. (note)

  7. Central respiratory chemosensitivity and cerebrovascular CO2 reactivity: a rebreathing demonstration illustrating integrative human physiology.

    Science.gov (United States)

    MacKay, Christina M; Skow, Rachel J; Tymko, Michael M; Boulet, Lindsey M; Davenport, Margie H; Steinback, Craig D; Ainslie, Philip N; Lemieux, Chantelle C M; Day, Trevor A

    2016-03-01

    One of the most effective ways of engaging students of physiology and medicine is through laboratory demonstrations and case studies that combine 1) the use of equipment, 2) problem solving, 3) visual representations, and 4) manipulation and interpretation of data. Depending on the measurements made and the type of test, laboratory demonstrations have the added benefit of being able to show multiple organ system integration. Many research techniques can also serve as effective demonstrations of integrative human physiology. The "Duffin" hyperoxic rebreathing test is often used in research settings as a test of central respiratory chemosensitivity and cerebrovascular reactivity to CO2. We aimed to demonstrate the utility of the hyperoxic rebreathing test for both respiratory and cerebrovascular responses to increases in CO2 and illustrate the integration of the respiratory and cerebrovascular systems. In the present article, methods such as spirometry, respiratory gas analysis, and transcranial Doppler ultrasound are described, and raw data traces can be adopted for discussion in a tutorial setting. If educators have these instruments available, instructions on how to carry out the test are provided so students can collect their own data. In either case, data analysis and quantification are discussed, including principles of linear regression, calculation of slope, the coefficient of determination (R(2)), and differences between plotting absolute versus normalized data. Using the hyperoxic rebreathing test as a demonstration of the complex interaction and integration between the respiratory and cerebrovascular systems provides senior undergraduate, graduate, and medical students with an advanced understanding of the integrative nature of human physiology. Copyright © 2016 The American Physiological Society.

  8. Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

    Science.gov (United States)

    Hughson, Richard L; Peterson, Sean D; Yee, Nicholas J; Greaves, Danielle K

    2017-11-01

    Pulse contour analysis of the noninvasive finger arterial pressure waveform provides a convenient means to estimate cardiac output (Q̇). The method has been compared with standard methods under a range of conditions but never before during spaceflight. We compared pulse contour analysis with the Modelflow algorithm to estimates of Q̇ obtained by rebreathing during preflight baseline testing and during the final month of long-duration spaceflight in nine healthy male astronauts. By Modelflow analysis, stroke volume was greater in supine baseline than seated baseline or inflight. Heart rate was reduced in supine baseline so that there were no differences in Q̇ by Modelflow estimate between the supine (7.02 ± 1.31 l/min, means ± SD), seated (6.60 ± 1.95 l/min), or inflight (5.91 ± 1.15 l/min) conditions. In contrast, rebreathing estimates of Q̇ increased from seated baseline (4.76 ± 0.67 l/min) to inflight (7.00 ± 1.39 l/min, significant interaction effect of method and spaceflight, P < 0.001). Pulse contour analysis utilizes a three-element Windkessel model that incorporates parameters dependent on aortic pressure-area relationships that are assumed to represent the entire circulation. We propose that a large increase in vascular compliance in the splanchnic circulation invalidates the model under conditions of spaceflight. Future spaceflight research measuring cardiac function needs to consider this important limitation for assessing absolute values of Q̇ and stroke volume. NEW & NOTEWORTHY Noninvasive assessment of cardiac function during human spaceflight is an important tool to monitor astronaut health. This study demonstrated that pulse contour analysis of finger arterial blood pressure to estimate cardiac output failed to track the 46% increase measured by a rebreathing method. These results strongly suggest that alternative methods not dependent on pulse contour analysis are required to track cardiac function in spaceflight

  9. Method of removing nitrogen monoxide from a nitrogen monoxide-containing gas using a water-soluble iron ion-dithiocarbamate, xanthate or thioxanthate

    Science.gov (United States)

    Liu, D. Kwok-Keung; Chang, Shih-Ger

    1987-08-25

    The present invention relates to a method of removing of nitrogen monoxide from a nitrogen monoxide-containing gas which method comprises contacting a nitrogen oxide-containing gas with an aqueous solution of water soluble organic compound-iron ion chelate complex. The NO absorption efficiency of ferrous urea-dithiocarbamate and ferrous diethanolamine-xanthate as a function of time, oxygen content and solution ph is presented. 3 figs., 1 tab.

  10. Features of the non-contact carotid pressure waveform: Cardiac and vascular dynamics during rebreathing

    Science.gov (United States)

    Casaccia, S.; Sirevaag, E. J.; Richter, E. J.; O'Sullivan, J. A.; Scalise, L.; Rohrbaugh, J. W.

    2016-10-01

    This report amplifies and extends prior descriptions of the use of laser Doppler vibrometry (LDV) as a method for assessing cardiovascular activity, on a non-contact basis. A rebreathing task (n = 35 healthy individuals) was used to elicit multiple effects associated with changes in autonomic drive as well as blood gases including hypercapnia. The LDV pulse was obtained from two sites overlying the carotid artery, separated by 40 mm. A robust pulse signal was obtained from both sites, in accord with the well-described changes in carotid diameter over the blood pressure cycle. Emphasis was placed on extracting timing measures from the LDV pulse, which could serve as surrogate measures of pulse wave velocity (PWV) and the associated arterial stiffness. For validation purposes, a standard measure of pulse transit time (PTT) to the radial artery was obtained using a tonometric sensor. Two key measures of timing were extracted from the LDV pulse. One involved the transit time along the 40 mm distance separating the two LDV measurement sites. A second measure involved the timing of a late feature of the LDV pulse contour, which was interpreted as reflection wave latency and thus a measure of round-trip travel time. Both LDV measures agreed with the conventional PTT measure, in disclosing increased PWV during periods of active rebreathing. These results thus provide additional evidence that measures based on the non-contact LDV technique might provide surrogate measures for those obtained using conventional, more obtrusive assessment methods that require attached sensors.

  11. Right-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing system Determinação de shunt venoso-arterial em pulmões de cães sob anestesia geral inalatória por sistemas com e sem reinalação

    Directory of Open Access Journals (Sweden)

    André Leguthe Rosa

    2006-12-01

    Full Text Available PURPOSE: To investigatge right-to-left shunt determination in dog lungs under inhalantion anesthesia with non-rebreathing and rebreathing systems and fraction of inspired oxygen (F I O2 of 0.9 and 0.4, respectively. METHODS: Two groups of 10 dogs each under inhalation anesthesia with sevoflurane: GI in which it was utilized non-rebreathing semiclosed system and F I O2 = 0.9, and GII in which it was utilized rebreathing semiclosed system and F I O2 = 0.4. The study parameters were: heart rate, medium arterial pressure, right-to-left intrapulmonary shunt, hematocrit, hemoglobin, arterial partial pressure of oxygen, mixed venous partial pressure of oxygen, mixed venous oxygen saturation, arterial partial pressure of carbon dioxide, partial pressure of water in the alveoli. RESULTS: Shunt results were significantly different between the two groups - GI data were higher than GII in all the evaluated moments. Hence, the group with nonrebreathing (GI developed a superior grade of intrapulmonary shunt when compared with the rebreathing group (GII. The partial pressure of water in the alveoli was significantly higher in GII. CONCLUSION: The inhalation anesthesia with non-rebreathing system and F I O2 = 0.9 developed a higher grade of intrapulmonary right-to-left shunt when compared with the rebreathing system and F I O2 = 0.4. The higher humidity in GII contributed to the result.OBJETIVO: Comparar a formação de shunt venoso-arterial em pulmões de cães submetidos a anestesia geral inalatória utilizando-se sistemas de anestesia com e sem reinalação, com fração inspirada de oxigênio de 0,4 e 0,9, respectivamente. MÉTODOS: Empregaram-se 20 cães induzidos com tiopental sódico (30mg/kg e mantidos com sevoflurano (3% e alocados em dois grupos (n=10; os animais de GI foram ventilados com modalidade controlada em sistema semifechado, sem reinalação, F I O2 = 0,9, e os de GII, com modalidade controlada, sistema semifechado, com reinalação e F I O2

  12. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes

    DEFF Research Database (Denmark)

    Fagoni, Nazzareno; Andersen, Andreas Breenfeldt; Oberholzer, Laura

    2018-01-01

    INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invas...

  13. Plasma volume in acute hypoxia

    DEFF Research Database (Denmark)

    Poulsen, T D; Klausen, T; Richalet, J P

    1998-01-01

    Exposure to acute hypoxia is associated with changes in body fluid homeostasis and plasma volume (PV). This study compared a dye dilution technique using Evans' blue (PV[Evans']) with a carbon monoxide (CO) rebreathing method (PV[CO]) for measurements of PV in ten normal subjects at sea level...

  14. Surface and 60 FSW Performance Testing of the Modified MBS 2000 Closed Circuit Oxygen Rebreather

    National Research Council Canada - National Science Library

    Fothergill, David

    2007-01-01

    ... into the system during a treatment. Since all previous testing had been performed at 1 ATA, a second major objective for the FY06 tests was to evaluate the modified MBS 2000 rebreather at 60 fsw in a hyperbaric chamber...

  15. Carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The document identifies the main sources of carbon monoxide (CO) in the general outdoor atmosphere, describes methods of measuring and monitoring its concentration levels in the United Kingdom, and discusses the effects of carbon monoxide on human health. Following its review, the Panel has put forward a recommendation for an air quality standard for carbon monoxide in the United Kingdom of 10 ppm, measured as a running 8-hour average. The document includes tables and graphs of emissions of CO, in total and by emission source, and on the increase in blood levels of carboxyhaemoglobin with continuing exposure to CO. 11 refs., 4 figs., 4 tabs.

  16. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Alisa Wray

    2016-07-01

    Full Text Available Audience: This oral boards case is appropriate for all emergency medicine learners (residents, interns, and medical students. Introduction: Carbon monoxide (CO is a colorless and odorless gas that typically results from combustion. It binds hemoglobin, dissociating oxygen, causing headache, weakness, confusion and possible seizure or coma. Pulse oxygen levels may be falsely elevated. Practitioners should maintain a high index of suspicion for carbon monoxide poisoning. If caught early CO poisoning is reversible with oxygen or hyperbaric oxygen therapy. Objectives: The learner will assess a patient with altered mental status and weakness, ultimately identifying that the patient has carbon monoxide poisoning. The learner will treat the patient with oxygen and admit/transfer the patient for hyperbaric oxygenation. Method: Oral boards case

  17. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Kamal Mishra

    2016-01-01

    Full Text Available Introduction: Carbon monoxide is known as the silent killer, being colorless, odourless, and tasteless. Initially non-irritating, it is very difficult for people to detect Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply that prevents complete oxidation of carbon to C02. During World War II, Nazis used gas vans to kill an estimated over 700,000 prisoners by carbon monoxide poisoning. This method was also used in the gas chambers ofseveral death camps. The true number of incidents of carbon monoxide poisoning is unknown, since many non-lethal exposures go undetected From the available data, carbon monoxide poisoning is the most common cause of injury and death due to poisoning worldwide. Clinical features and management: The signs of carbon monoxide poisoning vary with concentration and length of exposure. Subtle cardiovascular or neurobehavioural effects occur at low concentration. The onset of chronic poisoning is usually insidious and easily mistaken for viral prodrome, depression, or gastroenteritis in children. The classic sign of carbon monoxide poisoning which is actually more often seen in the dead than the living is appearing red-cheeked and healthy. Cherry pink colour develops in nails, skin and mucosa. In acute poisoning, common abnormalities of posture and tone are cogwheel rigidity, opisthotonus, spasticity or flaccidity and seizures. Retinal haemorrhages and the classic cherry red skin colour are seldom seen. Different people andpopulations may have different carbon monoxide tolerance levels. On average, exposures at 100ppm or greater is dangerous to human health. Treatment and prevention: The mainstay of treatment is 100% oxygen administration until the COHb level is normal When the patient is stable enough to be transported, hyperbaric oxygen (HBOT should be considered This treatment is safe and well tolerated Public education about the danger of carbon monoxide, with

  18. Vaporization study on vanadium monoxide and two-phase mixture of vanadium and vanadium monoxide by mass-spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over single phase vanadium monoxide VO 1.022 (s) and the two-phase mixture of vanadium metal (β phase) and vanadium monoxide were measured by mass-spectrometric method in the temperature range of 1,803 ∼ 1,990 and 1,703 ∼ 1,884 K, respectively. The main gas species over both systems were found to be VO(g) and V(g). The vapor pressure of VO(g) over the two-phase mixture of V(s) and VO(s) was a little lower than that over single phase VO(s). The vapor pressure of V(g) over the two-phase mixture was nearly equal to that over single phase. From the vapor pressure data, the enthalpies of vaporization, the enthalpies of formation for VO(g) and V(g) and the dissociation energy of VO(g) were determined. The oxygen partial pressure was calculated as a function of temperature from the vapor pressures of VO(g) and V(g), from which the partial molar enthalpies and entropies of oxygen in both systems were obtained. (author)

  19. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  20. Carbon monoxide: The 21st century poison that goes unnoticed

    International Nuclear Information System (INIS)

    Hoskins, J.A.

    1999-01-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described

  1. Carbon monoxide: The 21st century poison that goes unnoticed

    Energy Technology Data Exchange (ETDEWEB)

    Hoskins, J.A. [Reigate, Surrey (United Kingdom)

    1999-07-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described.

  2. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Safety Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as CO, is called the " ...

  3. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, ... Install one and check its batteries regularly. View Information About CO Alarms Other CO Topics Safety Tips ...

  4. Carbon Monoxide Safety

    Science.gov (United States)

    ... with the Media Fire Protection Technology Carbon monoxide safety outreach materials Keep your community informed about the ... KB | Spanish PDF 592 KB Handout: carbon monoxide safety Download this handout and add your organization's logo ...

  5. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... main content Languages 简体中文 English Bahasa Indonesia 한국어 Español ภาษาไทย Tiếng Việt Text Size: Decrease Font Increase ... Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as ...

  6. Carbon monoxide poisoning

    Science.gov (United States)

    ... Animals can also be poisoned by carbon monoxide. People who have pets at home may notice that their animals become ... or unresponsive from carbon monoxide exposure. Often the pets will ... these conditions. This can lead to a delay in getting help.

  7. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  8. Hydrogen bonding of formamide, urea, urea monoxide and their thio

    Indian Academy of Sciences (India)

    Ab initio and DFT methods have been employed to study the hydrogen bonding ability of formamide, urea, urea monoxide, thioformamide, thiourea and thiourea monoxide with one water molecule and the homodimers of the selected molecules. The stabilization energies associated with themonohydrated adducts and ...

  9. Occult carbon monoxide poisoning.

    Science.gov (United States)

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  10. Occupational medicine effects of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, W.M. [South African Society of Occupational Medicine (South Africa)

    1998-10-01

    Carbon monoxide can affect the body if it is inhaled or if liquid carbon monoxide comes in contact with the eyes or skin. The effects of overexposure are discussed and a brief explanation of the toxicological effects of CO given. Methods of control of CO from common operations (exhaust fumes of internal combustion engines, the chemical industry and foundries, welding, mines or tunnels, fire damp explosions, industrial heating) are by local exhaust ventilation or use of a respiratory protective device. The South African hazardous chemical substance regulation NO. R. 1179 of 25 August 1995 stipulates maximum safe levels of CO concentration. 4 refs., 1 photo.

  11. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    Science.gov (United States)

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  12. Inhibition of photosynthesis by carbon monoxide and suspension of the carbon monoxide inhibition by light

    Energy Technology Data Exchange (ETDEWEB)

    Gewitz, H S; Voelker, W

    1963-08-01

    The experimental subject was the autotroph Chlorella pyrenoidosa. It was found that growth conditions determine whether the alga is inhibited by carbon monoxide or not. Respiration and photosynthesis are inhibited by carbon monoxide if the cells have grown rapidly under high light intensities. The inhibition of respiration and photosynthesis found in such cells is completely reversible. The inhibition depends not only on carbon monoxide pressure, but also on the oxygen pressure prevailing at the same time. 5 references, 1 figure, 3 tables.

  13. Non-invasive measurement of cardiac output during anaesthesia. An evaluation of the soluble gas uptake method

    Energy Technology Data Exchange (ETDEWEB)

    Heneghan, C.P.; Branthwaite, M.A.

    1981-04-01

    A technique for measuring cardiac output which depends on the uptake of an inert soluble gas from the lungs has been evaluated during anesthesia. A respiratory mass spectrometer has been used to follow the concentrations of argon and freon-22 during passive rebreathing in anaesthetized patients before cardiopulmonary bypass. Values for cardiac output obtained with this technique are reproducible, but lower than those recorded using the direct Fick technique before and after the rebreathing manoeuvre. A reduction in cardiac output caused by vigorous rebreathing is the most likely explanation for the discrepancy and, although serial measurements of oxygen consumption may permit application of a correction factor, a method of measurement which causes significant haemodynamic disturbance cannot be recommended for widespread use.

  14. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    Science.gov (United States)

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  15. Occult Carbon Monoxide Poisoning

    OpenAIRE

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms ...

  16. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-01-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem. Images Figure 1 Figure 2 PMID:10379009

  17. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-07-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem.

  18. Carbon monoxide and carbon dioxide interaction with tantalum

    International Nuclear Information System (INIS)

    Belov, V.D.; Ustinov, Yu.K.; Komar, A.P.

    1978-01-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (α and β' 1 ) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the β' 1 state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10 12 sec -1 , and γ = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively. (Auth.)

  19. Carbon monoxide and carbon dioxide interaction with tantalum

    Energy Technology Data Exchange (ETDEWEB)

    Belov, V D; USTINOV, YU K; KOMAR, A P [AN SSSR, LENINGRAD. FIZIKO-TEKHNICHESKIJ INST.

    1978-03-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (..cap alpha.. and ..beta..'/sub 1/) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the ..beta..'/sub 1/ state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10/sup 12/ sec/sup -1/, and ..gamma.. = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively.

  20. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be safely...

  1. On the composition of nonstoichiometric europium monoxide

    International Nuclear Information System (INIS)

    Ignat'eva, N.I.

    1990-01-01

    Consideration is given to results of of investigation into chemical composition, homogeneity region, type of disordering of nonstoichiometric europium monoxide. Precision methods of X-ray diffraction, electron-microscopic, atomic-absorption chemical analysis were used. It is shown that lattice volume reduces with increase of oxygen content in the oxide. For monocrystal of EuO 1.01 composition a=5.146 A. All samples of europium monoxide are characterized by low conductivity. Conductivity value changes by two orders (from 10 -8 to 10 -6 Θ -1 ·cm -1 ) when passing from the sample of stoichiometric composition to maximally disordered one. The disordering is considered according to the type of charged cation vacancies, leading to occurrence of equivalent number of electron defects of positive holes. 4 refs.; 1 tab

  2. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  3. Thermal Reactions in Mixtures of Micron-sized Silicon Monoxide and Titanium Monoxide - Redox Paths Overcoming Passivation Shells.

    Czech Academy of Sciences Publication Activity Database

    Jandová, Věra; Pokorná, Dana; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, Petra; Pola, Josef

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 R&D Projects: GA TA ČR TA04010169 Institutional support: RVO:67985858 Keywords : silicon monoxide * titanium monoxide * hifh-temperature Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 1.369, year: 2016

  4. The Effect of Carbon Monoxide Poisoning on Platelet Volume in Children

    Directory of Open Access Journals (Sweden)

    Halise Akça

    2017-04-01

    Full Text Available Introduction: Carbon monoxide poisoning is one of the most important causes of morbidity and mortality. There is increasing evidence supporting the important role of mean platelet volume (MPV as a marker of hypoxia and inflammation. In this study, we aimed to determine changes in MPV values in pediatric patients with carbon monoxide poisoning. Methods: We retrospectively evaluated children who were diagnosed with carbon monoxide poisoning in our hospital between January 2005 and 2014. Results: We included 228 children with carbon monoxide poisoning (49% male in this retrospective, controlled study. The mean age of the patients was 88±56 months. Control group consisted of 200 age-matched healthy children. There was no statistically significant difference in MPV levels between the study and control groups (8.43±1.1 fL and 8.26±0.7 fL, respectively. No correlation of MPV and platelet count with carboxyhemoglobin (COHb was found. Conclusion: In our study, it was determined that MPV value was not a helpful parameter for predicting the diagnosis of acute carbon monoxide poisoning in childhood. The difference between the MPV values and the lack of significance and the absence of correlation between MPV value and COHb level led to the fact that MPV was not a guide indicating the clinical severity of the condition.

  5. Characteristics of exogenous carbon monoxide deliveries

    Directory of Open Access Journals (Sweden)

    Hui-jun Hu

    2016-01-01

    Full Text Available Carbon monoxide (CO has long been considered an environmental pollutant and a poison. Exogenous exposure to amounts of CO beyond the physiologic level of the body can result in a protective or adaptive response. However, as a gasotransmitter, endogenous CO is important for multiple physiologic functions. To date, at least seven distinct methods of delivering CO have been utilized in animal and clinical studies. In this mini-review, we summarize the exogenous CO delivery methods and compare their advantages and disadvantages.

  6. Thermal reactions in mixtures of micron-sized silicon monoxide and titanium monoxide: redox paths overcoming passivation shells

    Czech Academy of Sciences Publication Activity Database

    Jandová, V.; Pokorná, D.; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, P.; Pola, J.

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 Institutional support: RVO:61388980 Keywords : Silicon monoxide * Titanium monoxide * High-temperature * Oxygen-transfer reactions * Titanium suboxides * Titanium silicide * Methylene blue depletion Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.369, year: 2016

  7. Vacancy distribution in nonstoichiometric vanadium monoxide

    International Nuclear Information System (INIS)

    Gusev, A.I.; Davydov, D.A.; Valeeva, A.A.

    2011-01-01

    Graphical abstract: Display Omitted Research highlights: → A certain fraction of vanadium atoms in disordered cubic vanadium monoxide VO y and ordered tetragonal phase V 52 O 64 is located in tetrahedral positions of a basic cubic lattice. → These positions are never occupied by any atoms in other strongly nonstoichiometric carbides, nitrides and oxides. → Both disordered and ordered structures of vanadium monoxide are characterized by the presence of short-range order of displacements in the oxygen sublattice and short-range order of substitution in the metal sublattice. → The short-range order of displacement is caused by the local displacements of O atoms from V (t) atoms occupying tetrahedral positions. The short-range order of substitution appears because V (t) atoms in the tetrahedral positions are always in the environment of four vacancies □ of the vanadium sublattice. - Abstract: Structural vacancy distribution in the crystal lattice of the tetragonal V 52 O 64 superstructure which is formed on the basis of disordered superstoichiometric cubic vanadium monoxide VO y ≡V x O z is experimentally determined and the presence of significant local atomic displacements and large local microstrains in a crystal lattice of real ordered phase is established. It is shown that the relaxation of local microstrains takes place owing to the basic disordered cubic phase grain refinement and a formation of ordered phase domains. The ordered phase domains grow in the direction from the boundaries to the centre of grains of the disordered basic cubic phase. Isothermal evolution at 970 K of the average domain size in ordered VO 1.29 vanadium monoxide is established. It is shown that the short-range order presents in a metal sublattice of disordered cubic VO y vanadium monoxide. The character of the short-range order is such that vanadium atoms occupying tetrahedral positions are in the environment of four vacant sites of the vanadium sublattice. This means that the

  8. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    OpenAIRE

    Metin Uysalol; Ezgi Paslı Uysalol; Gamze Varol Saraçoğlu; Semra Kayaoğlu

    2011-01-01

    Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female) who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide into...

  9. Optimization of Treatment Policy for Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    R. N. Akalayev

    2012-01-01

    Full Text Available Objective: to evaluate the efficiency of combination use of hyperbaric oxygenation, succinate-containing solutions, and anti-edematous agents in patients with acute carbon monoxide poisoning. Subjects and methods. The results of treatment were analyzed in 32 patients admitted in 2009—2011 for severe acute carbon monoxide poisoning and a Glasgow coma score of 6—8. The patients were divided into 2 groups: 1 patients whose combination therapy involved hyperbaric oxygenation, Succinasol infusions, and L-lysine-aescinate injections; 2 those who received traditional therapy. All the patients underwent complex clinical, laboratory, and neurophysiologic examinations. Results. Just 24 hours after the combination use of Succinasol and L-lysine-aescinate, Group I patients were observed to have substantially reduced lactate, the content of the latter approached the normal value following 48 hours, which was much below the values in the control group. The similar pattern was observed when endogenous intoxication parameters were examined. During the performed therapy, the level of consciousness and that of intellect according to the MMSE and FAB scales were restored more rapidly in the study group patients than in Group 2. Conclusion. The combination use of hyperbaric oxygenation, the succinate-containing solution Succinasol, and the anti-edematous agent L-lysine-aescinate considerably enhances the efficiency of intensive therapy for acute carbon monoxide poisoning. Key words: carbon monoxide, toxic hypoxic encephalopathy, combination therapy, hyperbaric oxygenation, succinic acid, L-lysine-aescinate.

  10. Enzymic oxidation of carbon monoxide. II

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, T

    1959-01-01

    An enzyme which catalyzes the oxidation of carbon monoxide into carbon dioxide was obtained in a cell free state from Desulfovibrio desulfuricans. The enzyme activity was assayed manometrically by measuring the rate of gas uptake under the atmosphere of carbon monoxide in the presence of benzyl-viologen as an oxidant. The optimum pH range was 7 to 8. The activity was slightly suppressed by illumination. The enzyme was more stable than hydrogenase or formate dehydrogenase against the heat treatment, suggesting that it is a different entity from these enzymes. In the absence of an added oxidant, the enzyme preparation produced hydrogen gas under the atmosphere of carbon monoxide. The phenomenon can be explained assuming the reductive decomposition of water. 17 references, 4 figures, 2 tables.

  11. Bacterium oxidizing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kistner, A

    1953-01-01

    Present-day knowledge of the microbiological oxidation of carbon monoxide is based on doubtful observations and imperfect experimental procedures. By making use of shake cultures in contact with gas mixtures containing high concentrations of CO and by employing liquid enrichment media with a low content of organic matter and solid media of the same composition with not more than 1.2% agar, it proved possible to isolate a co-oxidizing bacterium of the genus hydrogenomonas from sewage sludge. For the first time irrefutable proof has been given of the oxidation of carbon monoxide by a pure culture of a bacterium, both in growing cultures and in resting cell suspensions. 12 references.

  12. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008

    International Nuclear Information System (INIS)

    Lefebvre, B.; Chabot, L.; Gratton, J.; Lacoursiere, D.

    2009-01-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  13. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Science.gov (United States)

    Kaminaga, Kenichi; Sei, Ryosuke; Hayashi, Kouichi; Happo, Naohisa; Tajiri, Hiroo; Oka, Daichi; Fukumura, Tomoteru; Hasegawa, Tetsuya

    Rare earth sesquioxides like Y2O3 are known as widegap insulators with the highly stable closed shell trivalent rare earth ions. On the other hand, rare earth monoxides such as YO have been recognized as gaseous phase, and only EuO and YbO were thermodynamically stable solid-phase rock salt monoxides. In this study, solid-phase rock salt yttrium monoxide, YO, was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO possesses unusual valence of Y2+ ([Kr] 4d1) . In contrast with Y2O3, YO was narrow gap semiconductor with dark-brown color. The electrical conductivity was tunable from 10-1 to 103 Ω-1 cm-1 by introducing oxygen vacancies as electron donor. Weak antilocalization behavior was observed indicating significant spin-orbit coupling owing to 4 d electron carrier. The absorption spectral shape implies the Mott-Hubbard insulator character of YO. Rare earth monoixdes will be new platform of functional oxides. This work was supported by JST-CREST, the Japan Society for the Promotion of Science (JSPS) with Grant-in-Aid for Scientific Research on Innovative Areas (Nos. 26105002 and 26105006), and Nanotechnology Platform (Project No.12024046) of MEXT, Japan.

  14. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  15. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Science.gov (United States)

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  16. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ...

  17. Search of medical literature for indoor carbon monoxide exposure

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  18. Delayed encephalopathy after acute carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet İbrahim Turan

    2014-03-01

    Full Text Available Carbon monoxide poisoning is a major cause of death following attempted suicide and accidental exposures. Although clinical presentation depends on the duration and the intensity of exposure, the assessment of the severity of intoxication is difficult. A small percentage of patients who show complete initial recovery may develop delayed neurological deficits. Delayed encephalopathy after acute carbon monoxide poisoning is a rare and poor prognosis neurologic disorders and there is no specific treatment. We present a case with early onset of delayed encephalopathy after acute carbon monoxide poisoning with typical cranial imaging findings in a child with atypical history and clinical presentation.

  19. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Import Surveillance International Recall Guidance Civil and Criminal Penalties Federal Court Orders & ... 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 ...

  20. Hydrogenation of carbon monoxide over supported palladium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K.; Hashimoto, H.; Kunugi, T.

    1978-03-01

    An alumina-supported 2% palladium catalyst had higher activity for carbon monoxide hydrogenation than a silica-supported 2% palladium catalyst, at 250/sup 0/-400/sup 0/C and 1 atm. The addition of lanthanum oxide or thorium oxide, but not of potassium oxide, to the silica-supported catalyst increased the conversion at 350/sup 0/C from 1.1% to 81.0% with a selectivity of 56.1% for methane, 1.4% for C/sub 2/ compounds, 0.1% for C/sub 3/ compounds, and 42.5% for carbon dioxide. Temperature-programed desorption of carbon monoxide in a hydrogen stream showed that of two desorption peaks observed for carbon monoxide, the one at higher temperature corresponded to the carbon monoxide species which hydrogenates to methane and that the area of this peak increased with increasing thorium content of the catalyst. Graphs, tables, and 12 references.

  1. Carbon Monoxide Nonattainment Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies areas in the U.S. where air pollution levels have not met the National Ambient Air Quality Standards (NAAQS) for Carbon Monoxide and have...

  2. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 Annual Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire ...

  3. The Range of 1-3 keV Electrons in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Oehlenschlæger, M.; Andersen, H.H.; Schou, Jørgen

    1985-01-01

    The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than that in n......The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than...

  4. Effect of vegetation in reducing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, J C

    1977-01-01

    Carbon monoxide is a product of incomplete combustion. Because almost all of this gas is produced by motor vehicles, it is considered to have a line rather than a stationary point source. Greatest concentrations of this lethal gas correspond to periods of peak traffic volume and congestion; therefore, there are two daily periods of maxima and minima. Carbon monoxide cannot be detected by sight or smell. For this reason, this gas is especially deadly. During the summer of 1975, a study involving carbon monoxide concentrations at selected sites in Sendai was undertaken in conjunction with an ongoing investigation of urban pollution under the directorship of Professor Toshio Noh of Tohoku University. This study was made possible by a grant from the Japan Society for the Promotion of Science. 5 references, 5 figures, 1 table.

  5. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Community Outreach Resource Center Toy Recall Statistics CO Poster Contest Pool Safely Business & Manufacturing Business & Manufacturing Business ... Featured Resources CPSC announces winners of carbon monoxide poster contest Video View the blog Clues You Can ...

  6. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  7. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ... 2011 Annual Estimates View All CO-Related Injury Statistics and Technical Reports Related Links Recalls Safety Education ...

  8. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... CONSUMER PRODUCT SAFETY COMMISSION Search CPSC Search Menu Home Recalls Recall List CPSC Recall API Recall Lawsuits ... and Bans Report an Unsafe Product Consumers Businesses Home Safety Education Safety Education Centers Carbon Monoxide Information ...

  9. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  10. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide ... Related Links Recalls Safety Education Regulations, Laws & Standards Research & Statistics Business & Manufacturing Small Business Resources OnSafety Blogs ...

  11. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Español The Invisible Killer Carbon monoxide, also known as CO, is called the "Invisible Killer" because it's ... used or incorrectly-vented fuel-burning appliances such as furnaces, stoves, water heaters and fireplaces. Watch This ...

  12. Effect of N-Acetylcysteine in Protecting from Simultaneous Noise and Carbon Monoxide Induced Hair Cell Loss

    Directory of Open Access Journals (Sweden)

    Akram Pourbakht

    2011-06-01

    Full Text Available Background and Aim: N-acetylcysteine, a glutathione precursor and reactive oxygen species scavenger, is reported to be effective in reducing noise-induced hearing loss. Many workers in industry are exposed simultaneously to noise and chemical pollutants such as carbon monoxide. We investigated effectiveness of N-acetylcysteine in protecting the cochlea from simultaneous noise and carbon monoxide damages.Methods: Twelve rabbits were exposed simeltaneously to 100 dB sound pressure level of broad band noise and carbon monoxide 8 hours a day for 5 days. One hour before exposure, experimental group received 325 mg/kg of N-acetylcysteine while normal saline was administered for the control group. The protective effect of N-acetylcysteine was evaluated 3 weeks after exposure by histological assessment of the hair cells.Results: Simultaneous exposure to noise and carbon monoxide resulted in a considerable damage to the outer hair cells; however, the inner hair cells and the pillar cells remained intact. Use of N-acetylcysteine in the experimental group significantly reduced the extent of outer hair cell loss.Conclusion: N-acetylcysteine attenuates simultaneous noise and carbon monoxide induced hair cell damage in rabbits.

  13. Health effects of carbon monoxide environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    Carbon monoxide's (CO) chronic effects on man, its sources, and measuring methods are reviewed, and guidelines to determine health criteria are considered. The European data exchange included CO measuring methods in air and blood and their use in survey and experimental work, atmospheric CO pollution and sampling methods in urban thoroughfares and road tunnels in the European countries, a population survey of carboxyhemoglobin levels from cigarette smoking and atmospheric exposure, and physiological kinetics (uptake, distribution, and elimination) of CO inhalation. Additional topics are CO and the central nervous system, effects of moderate CO exposure on the cardiovascular system and on fetal development, and the current views on existing air quality criteria for CO.

  14. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Investigations Associated with Non-Fire Carbon Monoxide from Engine-Driven Generators and Other Engine-Driven Tools, 2004–2014 JANUARY 08, 2015 Non- ... outside of the Federal Government. CPSC does not control this external site or its privacy policy and ...

  15. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Sevinc, A.; Savli, H.; Atmaca, H. [Gaziantep University, Gaziantep (Turkey). School of Medicine

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  16. Polyketones as alternating copolymers of carbon monoxide

    International Nuclear Information System (INIS)

    Belov, Gennady P; Novikova, Elena V

    2004-01-01

    Characteristic features of the catalytic synthesis of alternating copolymers of carbon monoxide with various olefins, dienes, styrene and its derivatives are considered. The diversity of catalyst systems used for the copolymerisation of carbon monoxide is demonstrated and their influence on the structure and the molecular mass of the resulting copolymers is analysed. The data on the structure and physicochemical and mechanical properties of this new generation of functional copolymers are generalised and described systematically for the first time.

  17. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker...... after an acute exposure to carbon monoxide. This complication was diagnosed by pure-tone audiometry and confirmed by transient evoked otoacoustic emissions. Hearing loss has not improved after 3 months of followup....

  18. Development of an enzymatic sensor for carbon monoxide

    International Nuclear Information System (INIS)

    Hurtado, Clara; Gomez, Diana; Larmat, Fernando; Torres, Walter; Cuervo, Raul; Bravo, Enrique; Benitez, Neyla

    2003-01-01

    The detection and the pursuit of gases that contribute in the increase of the atmospheric contamination are a necessity, for what the electrochemical sensors have potential industrial applications for the control of the quality of the air. The development of amperometric sensor based on enzymes offers advantages, since the use of the biological component provides him high selectivity due to the great specificity of the substrate of the enzyme. The monoxide of carbon (CO) it is a polluting, poisonous gas, taken place during the incomplete combustion of organic materials (natural gas, petroleum, gasoline, coal and vegetable material). The determination of monoxide of carbon (CO) it can be reached by electrochemical mediums using the methylene blue like the electronic mediator for the enzyme monoxide of carbon oxidase (COx)

  19. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Science.gov (United States)

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  20. Carbon monoxide exposure in households in Ciudad Juárez, México.

    Science.gov (United States)

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  1. Metallic and insulating 3d transition-element monoxides and their stability

    International Nuclear Information System (INIS)

    Johansson, H.B.

    1977-01-01

    The binding properties of the 3d monoxides are studied in detail, and it is shown that the metallic character of TiO and VO is directly reflected in their heat of formation. The same holds true for NbO. From a stability analysis of the 3d monoxides versus decomposition, it is found that TiO, VO, and FeO are close to an instability. Further, it can be concluded that both ScO and CrO must be very near existence. The general occurrence of transition-metal monoxides is shown to be directly correlated with ionic properties of the transition elements. An investigation of the absorption edge in the 3d monoxides is also undertaken. The importance of the crystal-field splitting is noticed, and it is shown that the heat of formation of the monoxides can be used to derive the crystal-field parameter Δ. The change from a delocalized to a localized behavior of the d electrons in the 3d monoxides is compared with a similar change of the f electrons in the actinides. Some similarities between these two series of materials are pointed out

  2. Carbon monoxide poisoning in Nigeria - it is time to pay attention ...

    African Journals Online (AJOL)

    Background: Carbon monoxide (CO) is a colourless, odourless gas and a cause of thousands of deaths across the world annually but its lethal consequences often go unrecognized, especially in developing countries. Aim: To discuss the subject of CO poisoning using local examples. Methods: Information was drawn from ...

  3. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Science.gov (United States)

    2010-07-01

    ... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration. Prior... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  4. Carbon monoxide poisoning from waterpipe smoking: a retrospective cohort study.

    Science.gov (United States)

    Eichhorn, Lars; Michaelis, Dirk; Kemmerer, Michael; Jüttner, Björn; Tetzlaff, Kay

    2018-04-01

    Waterpipe smoking may increasingly account for unintentional carbon monoxide poisoning, a serious health hazard with high morbidity and mortality. We aimed at identifying waterpipe smoking as a cause for carbon monoxide poisoning in a large critical care database of a specialty care referral center. This retrospective cohort study included patients with a history of exposure to waterpipe smoking and carbon monoxide blood gas levels >10% or presence of clinical symptoms compatible with CO poisoning admitted between January 2013 and December 2016. Patients' initial symptoms and carbon monoxide blood levels were retrieved from records and neurologic status was assessed before and after hyperbaric oxygen treatment. Sixty-one subjects with carbon monoxide poisoning were included [41 males, 20 females; mean age 23 (SD ± 6) years; range 13-45] with an initial mean carboxyhemoglobin of 26.93% (SD ± 9.72). Most common symptoms included syncope, dizziness, headache, and nausea; 75% had temporary syncope. Symptoms were not closely associated with blood COHb levels. CO poisoning after waterpipe smoking may present in young adults with a wide variability of symptoms from none to unconsciousness. Therefore diagnosis should be suspected even in the absence of symptoms.

  5. Theoretical studies on the catalytic oxidation of carbon monoxide on nickel clusters

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, A.K.; Kojima, I.; Miyazaki, E.

    1986-01-01

    Complete neglect of differential overlap (CNDO) molecular orbital calculations using the method of Anno and Sakai for the evaluation of the valence orbital ionization potential (VOIP) were performed with the aim of studying the oxidation of carbon monoxide on nickel clusters. A cluster surface was assumed to be preadsorbed with oxygen and the variation of various bond energies with the approach of a carbon monoxide molecule was studied for different models. Various possibilities for the reaction path are discussed in the light of the theoretical findings and it is suggested that at a low coverage of oxygen the reaction may follow a Langmuir-Hinshelwood path, whereas at a high coverage, an Eley-Rideal path might be more probable. 55 references, 13 figures.

  6. Carbon monoxide poisoning - Immediate diagnosis and treatment are crucial to avoid complications.

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, L.D. [Case Western Reserve University, Cleveland, OH (United States)

    2006-03-15

    Carbon monoxide is an odorless, colorless, tasteless gas produced by the incomplete combustion of carbon-containing fuels (oil, kerosene, coal, wood) or the inadequate ventilation of natural gas. When carbon monoxide is introduced into the bloodstream, it binds to hemoglobin, reducing the number of binding sites available for oxygen. Carbon monoxide also changes the structure of the hemoglobin molecule, which makes it even more difficult for oxygen that has attached to be released into tissues. The resulting tissue ischemia can lead to organ failure, permanent changes in cognition, or death. Carbon monoxide poisoning is the leading cause of death by poisoning in industrialized countries.

  7. Range measurements of keV hydrogen ions in solid oxygen and carbon monoxide

    International Nuclear Information System (INIS)

    Schou, J.; Soerensen, H.; Andersen, H.H.; Nielsen, M.; Rune, J.

    1984-01-01

    Ranges of 1.3-3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen. The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees with that previously found for solid nitrogen. (orig.)

  8. Analysis of S-nitrosothiols via Copper Cysteine (2C) and Copper Cysteine - Carbon Monoxide (3C) Methods

    Science.gov (United States)

    Rogers, Stephen C.; Gibbons, Lindsey B.; Griffin, Sherraine; Doctor, Allan

    2012-01-01

    This chapter summarizes the principles of RSNO measurement in the gas phase, utilizing ozone-based chemiluminescence and the copper cysteine (2C) ± carbon monoxide (3C) reagent. Although an indirect method for quantifying RSNOs, this assay represents one of the most robust methodologies available. It exploits the NO• detection sensitivity of ozone based chemiluminscence, which is within the range required to detect physiological concentrations of RSNO metabolites. Additionally, the specificity of the copper cysteine (2C and 3C) reagent for RSNOs negates the need for sample pretreatment, thereby minimizing the likelihood of sample contamination (false positive results), NO species inter-conversion, or the loss of certain highly labile RSNO species. Herein, we outline the principles of this methodology, summarizing key issues, potential pitfalls and corresponding solutions. PMID:23116707

  9. Pulmonary edema in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk

    1974-01-01

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis

  10. Pulmonary edema in acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis.

  11. Carbon monoxide and COHb concentration in blood in various circumstances

    Energy Technology Data Exchange (ETDEWEB)

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  12. [Economic assessment of low flow anesthesia with analysis of the break-even point. Experience at an underutilized operating room].

    Science.gov (United States)

    Varesio, V; Agosta, I; Masullo, F; Malnati, R; Martegani, G M

    1997-04-01

    Many authors indicate the importance of economic saving obtained with the use of the inhalation rebreathing anaesthesia instead of non rebreathing anaesthesia, always referring to parameters which are the duration of anesthesia (1 hour) and the use of the operating theatre each year. It is presumed that the utilization of rebreathing system is at least a 1.000 hours/year. However it is not necessary that all the operating theatres employ 1.000 hours/year in rebreathing anesthesia. This method requires annual depreciation costs of the capital invested for the purchase of new adequate ventilators, to modificative those already existing and guarantee adequate monitoring and the maintenance of these equipment. The importance is stressed of individuating a method of economical evaluation comparing the effective savings obtained with the real utilization of rebreathing anesthesia for each operating theatre and the costs of purchasing and maintaining the equipment. From our point of view the break-even point analysis has demonstrated to be a consistent instrument for the evaluation of the real economic advantage of rebreathing system in each hospital. It is suggested to utilize a conventional formula for the determination of the break even point, which means the minimal number of hours for year that justifies economically the adoption of rebreathing anaesthesia. An example of this analysis has been applied for an operating theatre in the hospital of Morbegno, where the major utilization of regional anaesthesia leads to a reduced number hours/year of rebreathing anesthesia which remains anyhow economically advantageous.

  13. Poisoning by carbon monoxide in Morocco from 1991 to 2008.

    Science.gov (United States)

    Aghandous, Rachida; Chaoui, Hanane; Rhalem, Naima; Semllali, Ilham; Badri, Mohamed; Soulaymani, Abdelmajid; Ouammi, Lahcen; Soulaymani-Bencheikh, Rachida

    2012-04-01

    To describe the characteristics relating to the provenance of statements, patients and to evaluate the spatiotemporal evolution of carbon monoxide poisoning reported to Poison Control Center and Pharmacovigilance of Morocco (CAPM). This is a retrospective study over a period of 18 years from 1991 to 2008, for all cases of poisoning by carbon monoxide reported to CAPM. The epidemiological study focused on 12 976 cases of carbon monoxide poisoning reported to CAPM between 1991 and 2008. The average age of patients was 25.5 +/- 15.6 years, sex ratio was 0.5. The poisoning occurred by accident in 98.7% of cases, especially at home (96.7%) and in cold months. The urban population was the most affected (89.0%). The region of Meknes Tafilalt was the most concerned with 16.6% of cases. The symptomatology was characterized by the predominance of gastrointestinal tract diseases (37.1%). Deaths have reached a percentage of 0.9%. These qualitative and quantitative information is useful to highlight warnings and plan a strategy against carbon monoxide poisoning in Morocco.

  14. Carbon monoxide, smoking, and atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Astrup, P

    1973-10-01

    Studies on the effects of carbon monoxide and smoking on atherosclerosis are reviewed. Nonsmokers do not run the risk of getting significantly elevated carboxyhemoglobin levels from automobile exhaust in the streets, however, they do run the risk of getting elevated carboxyhemoglobin levels from exposure to CO in closed areas such as garages and tunnels. Carboxyhemoglobin levels up to 20 percent may also be found in smokers. The central nervous system seems to be influenced by carboxyhemoglobin concentrations up to 20 percent. The myocardium may also be affected. Experimental work with rabbits exposed to carbon monoxide and cholesterol is described which proved that CO has a damaging effect on arterial walls, leading to increased permeability for various plasma components, to the formation of subendothelial edema, and to increased atheromatosis. The results indicate that the much higher risk of smokers of developing arterial disease in comparison to nonsmokers is mainly due to the inhaled CO in the tobacco smoke and not to nicotine. (Air Pollut. Abstr.)

  15. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    Directory of Open Access Journals (Sweden)

    Yong-Jian Ma

    2016-01-01

    Full Text Available This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0±5.9 d rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0±4.0 d, and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0±2.9 d were statistically similar (all p>0.05 to and linearly correlated (r=0.96, p<0.01 with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0±2.7 d; RIB10, 33.0±1.3 d; and RIB20, 27.0±0.8 d. The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.

  16. Protect Yourself from Carbon Monoxide Poisoning

    Centers for Disease Control (CDC) Podcasts

    2007-11-20

    Learn about carbon monoxide - a colorless, odorless gas - and how to protect yourself and your family.  Created: 11/20/2007 by CDC National Center for Environmental Health.   Date Released: 12/4/2007.

  17. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Science.gov (United States)

    2010-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  18. [Protective effects of endogenous carbon monoxide against myocardial ischemia-reperfusion injury in rats].

    Science.gov (United States)

    Zhou, Zhen; Ma, Shuang; Liu, Jie; Ji, Qiao-Rong; Cao, Cheng-Zhu; Li, Xiao-Na; Tang, Feng; Zhang, Wei

    2018-04-25

    The present study is aimed to explore the effects of endogenous carbon monoxide on the ischemia-reperfusion in rats. Wistar rats were intraperitoneally injected with protoporphyrin cobalt chloride (CoPP, an endogenous carbon monoxide agonist, 5 mg/kg), zinc protoporphyrin (ZnPP, an endogenous carbon monoxide inhibitor, 5 mg/kg) or saline. Twenty-four hours after injection, the myocardial ischemia-reperfusion model was made by Langendorff isolated cardiac perfusion system, and cardiac function parameters were collected. Myocardial cGMP content was measured by ELISA, and the endogenous carbon monoxide in plasma and myocardial enzymes in perfusate at 10 min after reperfusion were measured by colorimetry. The results showed that before ischemia the cardiac functions of CoPP, ZnPP and control groups were stable, and there were no significant differences. After reperfusion, cardiac functions had significant differences among the three groups (P endogenous carbon monoxide can maintain cardiac function, shorten the time of cardiac function recovery, and play a protective role in cardiac ischemia-reperfusion.

  19. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    Science.gov (United States)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  20. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  1. Forensic aspects of carbon monoxide poisoning by charcoal burning in Denmark, 2008-2012

    DEFF Research Database (Denmark)

    Nielsen, Pia Rude; Gheorghe, Alexandra; Lynnerup, Niels

    2014-01-01

    Carbon monoxide (CO) inhalation is a well-known method of committing suicide. There has been a drastic increase in suicide by inhalation of CO, produced from burning charcoal, in some parts of Asia, and a few studies have reported an increased number of these deaths in Europe. CO-related deaths c...

  2. CW-Laser-Induced Solid-State Reactions in Mixed Micron-Sized Particles of Silicon Monoxide and Titanium Monoxide: Nano-Structured Composite with Visible Light Absorption

    Czech Academy of Sciences Publication Activity Database

    Křenek, T.; Tesař, J.; Kupčík, Jaroslav; Netrvalová, M.; Pola, M.; Jandová, Věra; Pokorná, Dana; Cuřínová, Petra; Bezdička, Petr; Pola, Josef

    2017-01-01

    Roč. 27, č. 6 (2017), s. 1640-1648 ISSN 1574-1443 Institutional support: RVO:61388980 ; RVO:67985858 Keywords : Cw CO2 laser heating * IR laser imaging * Silicon monoxide * Solid state redox reactions * Ti/Si/O composite * Titanium monoxide Subject RIV: CA - Inorganic Chemistry; CI - Industrial Chemistry, Chemical Engineering (UCHP-M) OBOR OECD: Inorganic and nuclear chemistry; Chemical process engineering (UCHP-M) Impact factor: 1.577, year: 2016

  3. New Class of Hybrid Materials for Detection, Capture, and "On-Demand" Release of Carbon Monoxide.

    Science.gov (United States)

    Pitto-Barry, Anaïs; Lupan, Alexandru; Ellingford, Christopher; Attia, Amr A A; Barry, Nicolas P E

    2018-04-25

    Carbon monoxide (CO) is both a substance hazardous to health and a side product of a number of industrial processes, such as methanol steam reforming and large-scale oxidation reactions. The separation of CO from nitrogen (N 2 ) in industrial processes is considered to be difficult because of the similarities of their electronic structures, sizes, and physicochemical properties (e.g., boiling points). Carbon monoxide is also a major poison in fuel cells because of its adsorption onto the active sites of the catalysts. It is therefore of the utmost economic importance to discover new materials that enable effective CO capture and release under mild conditions. However, methods to specifically absorb and easily release CO in the presence of contaminants, such as water, nitrogen, carbon dioxide, and oxygen, at ambient temperature are not available. Here, we report the simple and versatile fabrication of a new class of hybrid materials that allows capture and release of carbon monoxide under mild conditions. We found that carborane-containing metal complexes encapsulated in networks made of poly(dimethylsiloxane) react with CO, even when immersed in water, leading to dramatic color and infrared signature changes. Furthermore, we found that the CO can be easily released from the materials by simply dipping the networks into an organic solvent for less than 1 min, at ambient temperature and pressure, which not only offers a straightforward recycling method, but also a new method for the "on-demand" release of carbon monoxide. We illustrated the utilization of the on-demand release of CO from the networks by carrying out a carbonylation reaction on an electron-deficient metal complex that led to the formation of the CO-adduct, with concomitant recycling of the gel. We anticipate that our sponge-like materials and scalable methodology will open up new avenues for the storage, transport, and controlled release of CO, the silent killer and a major industrial poison.

  4. New reduced variant in gadolinium and samarium monoxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Bist, B M.S.; Kumar, J; Srivastava, O N [Banaras Hindu Univ. (India). Dept. of Physics

    1977-01-01

    A new reduced phase has been observed in the thin films of gadolinium and samarium monoxides. This phase results on imparting an annealing treatment to the monoxides and is formed as a result of the creation and ordering of vacancies in the oxygen sublattice. The new phase has been analysed to possess a rhombohedral unit cell with lattice parameters a/sub R/ = a/sub 0/ square root of (3/2) and c/sub R/ = a/sub 0/ square root of 3 (based on hexagonal axes, a/sub 0/ being the lattice parameter of the fundamental zinc blende type unit cell of the monoxide). Based on the proposed structure, the new phase can be assigned the solid state chemical formula RO/sub x/ where R = Gd, Sm and x = 0.66.

  5. Conversion of no-carrier-added [11C]carbon dioxide to [11C]carbon monoxide on molybdenum for the synthesis of 11C-labelled aromatic ketones

    International Nuclear Information System (INIS)

    Zeisler, S.K.; Nader, M.; Theobald, A.; Oberdorfer, F.

    1997-01-01

    A new method for the efficient conversion of no-carrier-added [ 11 C]carbon dioxide into [ 11 C]carbon monoxide is described. [ 11 C]Carbon dioxide produced by proton bombardment of ultra high purity nitrogen is pre-concentrated in a cryo trap and then passed through a quartz tube filled with a mesh of thin molybdenum wire heated to 850 o C. [ 11 C]Carbon dioxide readily reacts with molybdenum to form [ 11 C]carbon monoxide and molybdenum(IV) oxide. The latter also reduces carbon dioxide to carbon monoxide and helps improve the performance of the converter. [ 11 C]Carbon monoxide is purified from remaining [ 11 C]carbon dioxide and collected in a small silica trap from which it is eluted into a reaction mixture for the palladium-mediated synthesis of a 11 C-labelled aromatic ketone. Radiochemical yields of up to 81% (decay-corrected) for [ 11 C]carbon monoxide were obtained. Radiochemical purity and specific radioactivity of both [ 11 C]carbon monoxide and the 11 C-labelled ketone are sufficient for nuclear medical studies with PET. (Author)

  6. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  7. Toxicological Investigation of Acute Carbon Monoxide Poisoning in Four Occupants of a Fuming Sport Utility Vehicle

    Directory of Open Access Journals (Sweden)

    Martin Nnoli

    2014-11-01

    Full Text Available Background: This toxicological investigation involves a report on the death of four occupants of a sport utility vehicle on one of the major busy Federal roads of Nigeria where they were held for up to three hours in a traffic jam while the car was steaming. Methods: Autopsy was executed using the standard procedure and toxicological analysis was done using simple spectrophotometric method to establish the level of carboxyhaemoglobin (HbCO in peripheral blood in the four occupants. Results: The autopsy report indicated generalized cyanosis, sub-conjuctival hemorrhages, marked laryngo-trachea edema with severe hyperemia with frothy fluid discharges characteristic of carbon monoxide poisoning. Toxicological report of the level of HbCO in part per million (ppm in the peripheral blood of the four occupants was A= 650 ppm; B= 500 ppm; C= 480 ppm, and D= 495 ppm against the maximum permissible level of 50 ppm. Conclusion: The sudden death of the four occupants was due to excessive inhalation of the carbon monoxide gas from the exhaust fumes leaking into the cabin of the car. The poor road network, numerous potholes, and traffic jam in most of roads in Nigeria could have exacerbated a leaky exhaust of the smoky second hand SUV car leading to the acute carbon monoxide poisoning.

  8. Carbon monoxide may be an important molecule in migraine and other headaches

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Schytz, Henrik W; Hauge, Mette K

    2014-01-01

    INTRODUCTION: Carbon monoxide was previously considered to just be a toxic gas. A wealth of recent information has, however, shown that it is also an important endogenously produced signalling molecule involved in multiple biological processes. Endogenously produced carbon monoxide may thus play...

  9. CARBON MONOXIDE AND THE NERVOUS SYSTEM

    Science.gov (United States)

    Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and there...

  10. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    Directory of Open Access Journals (Sweden)

    Metin Uysalol

    2011-09-01

    Full Text Available Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide intoxication was heaters, waterheaters and fi re in 82.1%, 7.1% and 6% of cases, respectively. There was a statistically signifi cant difference between the carboxyhemoglobin levels of the patients according to the clinical classifi cation (p<0.05. The intoxication caused by heaters was observed signifi cantly in November, December and January (p<0.001, between 16:00-24:00 hours (p<0.001 and among more than one member of a family (p<0.001. A medium level correlation was detected between the treatment approach and clinical classifi cation (r=0.50, p<0.001. Conclusion: Carbon monoxide intoxication, in the presented series, was found to develop accidentally; mostly in the Winter season; during night hours when the family members gathered together. The carboxyhemoglobin levels were appropriate with the developing clinical findings. Carboxyhemoglobin level solely was not enough for achieving the diagnosis and planning the treatment.

  11. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  12. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  13. Carbon Monoxide Exposure in Youth Ice Hockey.

    Science.gov (United States)

    Macnow, Theodore; Mannix, Rebekah; Meehan, William P

    2017-11-01

    To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.

  14. Catalytic Copolymerization of Ethene and Carbon Monoxide on Nickel Complexes.

    Science.gov (United States)

    Domhöver, Bernd; Kläui, Wolfgang; Kremer-Aach, Andreas; Bell, Ralf; Mootz, Dietrich

    1998-11-16

    Can palladium be replaced by nickel? For the industrial copolymerization of carbon monoxide and ethene a palladium catalyst is used which cannot be recovered-a cheaper procedure would be desirable. The presented complex 1 is the first structurally characterized nickel compound which does not polymerize ethene but a mixture from carbon monoxide and ethene unter mild conditions to give a perfectly alternating polyketone. © 1998 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  15. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Science.gov (United States)

    2010-07-01

    ....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Oxides of nitrogen, carbon monoxide...

  16. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Science.gov (United States)

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  17. Development of CuxFe/Al2O3 catalysts for the hydrogenation of carbon monoxide guided by magnetic methods, Moessbauer and infrared spectroscopy

    International Nuclear Information System (INIS)

    Boellaard, E.; Geus, J.W.; Bruggen, J.M. van; Kraan, A.M. van der

    1993-01-01

    A copper-iron catalyst for the hydrogenation of carbon monoxide has been prepared using a supported stoichiometric cyanide complex. Conversion of the cyanide precursor to a metallic catalyst appeared to be a precious process. Copper and iron in the bimetallic particles easily separate by thermal treatment and upon exposure to carbon monoxide, as revealed from Moessbauer and infrared spectroscopy. During Fischer-Tropsch reaction the catalyst exhibits a rapid decline of activity. Magnetisation measurements on spent catalysts indicate that the deactivation is caused by a fast conversion of metallic iron to initially unstable carbides which transform ultimately to more stable carbides. (orig.)

  18. Mechanism of obtaining carbon monoxide and hydrogen during brown coal radiolysis. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rustamov, V R; Kurbanov, M A; Dzantiev, B T; Kerimov, V K; Musaeva, P F

    1982-05-01

    This article analyzes effects of gamma radiation on the yield of products of coal gasification: hydrogen and carbon monoxide. Samples of brown coal from the Kansk-Achins basin were treated by gamma radiation with cobalt 60 radiation source. Analyses show that accumulation of hydrogen and carbon monoxide in brown coal under influence of gamma radiation is characterized by a constant rate. Yields of carbon monoxide and hydrogen amount to 0.16 molecule/100 electro volt and 0.21 molecule/electro volt respectively. Reducing radiation dose from 2.5 to 0.7 millirad/h reduces yields of hydrogen and carbon monoxide. Increasing temperature of vacuum brown coal pyrolysis from 200 to 600 C causes decrease of hydrogen yield. Hydrogen yield decrease during temperature increase is caused by a high content of aromatic nuclei in the samples used in the radiolysis. (5 refs.)

  19. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  20. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  1. Study on the surface oxidation resistance of uranium metal in the atmosphere of carbon monoxide

    International Nuclear Information System (INIS)

    Wang Xiaolin; Fu Yibei; Xie Renshou

    1999-01-01

    The surface reactions of different layers on uranium metal with carbon monoxide at 25, 80 and 200 degree C are studied by X-ray photoelectron spectroscopy (XPS). The experimental results show that the carbon monoxide is adsorbed on the surface oxide layer of uranium and interacted each other. The content of oxygen in the surface oxide and O/U ratio are decreased with increasing the exposure of carbon monoxide to the surface layer. The effect of reduction on the metal surface is more obviously with a higher temperature and increasing of layer thickness. The investigation indicates the uranium metal has resistance to further oxidation in the atmosphere of carbon monoxide

  2. XPS study on the surface reaction of uranium metal with carbon monoxide at 200 degree C

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-12-01

    The surface reaction of uranium metal with carbon monoxide at 200 degree C has been studied by X-ray photoelectron spectroscopy (XPS). The carbon monoxide adsorption on the surface oxide layer resulted in U4f peak shifting to the lower binding energy and the content of oxygen in the oxide is decreased. O/U radio decreases with increasing the exposure of carbon monoxide to the surface layer. The investigation indicated the surface layer of uranium metal was further reduced in the atmosphere of carbon monoxide at high temperature. (3 refs., 5 figs.)

  3. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    Energy Technology Data Exchange (ETDEWEB)

    Inui, Y. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)]. E-mail: inui@eee.tut.ac.jp; Urata, A. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Ito, N. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Nakajima, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Tanaka, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)

    2006-08-15

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide.

  4. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    International Nuclear Information System (INIS)

    Inui, Y.; Urata, A.; Ito, N.; Nakajima, T.; Tanaka, T.

    2006-01-01

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide

  5. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    Science.gov (United States)

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  6. Chemical production from waste carbon monoxide: its potential for energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Rohrmann, C.A.; Schiefelbein, G.F.; Molton, P.M.; Li, C.T.; Elliott, D.C.; Baker, E.G.

    1977-11-01

    Results of a study of the potential for energy conservation by producing chemicals from by-product or waste carbon monoxide (CO) from industrial sources are summarized. Extensive compilations of both industrial sources and uses for carbon monoxide were developed and included. Reviews of carbon monoxide purification and concentration technology and preliminary economic evaluations of carbon monoxide concentration, pipeline transportation and utilization of CO in the synthesis of ammonia and methanol are included. Preliminary technical and economic feasibility studies were made of producing ammonia and methanol from the by-product CO produced by a typical elemental phosphorus plant. Methanol synthesis appears to be more attractive than ammonia synthesis when using CO feedstock because of reduced water gas shift and carbon dioxide removal requirements. The economic studies indicate that methanol synthesis from CO appears to be competitive with conventional technology when the price of natural gas exceeds $0.82/million Btu, while ammonia synthesis from CO is probably not competitive until the price of natural gas exceeds $1.90/million Btu. It is concluded that there appears to be considerable potential for energy conservation in the chemical industry, by collecting CO rather than flaring it, and using it to make major chemicals such as ammonia and methanol.

  7. The Future of Carbon Monoxide Measurements from Space

    Science.gov (United States)

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  8. Chlorination of niobium oxide in the presence of carbon monoxide

    International Nuclear Information System (INIS)

    Freitas, L.R. de

    1984-01-01

    The chlorination kinetics of niobium pentoxide in the presence of carbon monoxide between 500-800 0 C of temperature is studied. The following variable that influences on the reaction rate are analysed: gas flow, geometry and volume of the Nb 2 O 5 samples, reaction temperature and composition of the chlorinated mixture. At the same time, two other materials were studied: the CaO.Nb 2 O 5 (synthetized in laboratory) and pyrochlorine concentrates. The three materials are compared for the chlorination method used. (M.A.C.) [pt

  9. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    OpenAIRE

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been o...

  10. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    Science.gov (United States)

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  11. Modeling chemisorption kinetics of carbon monoxide on polycrystalline platinum

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, R.G.; Modell, M.; Baddour, R.F.

    1978-04-01

    Seven distinct desorption surface states of carbon monoxide on polycrystalline platinum were detected by deconvoluting temperature-programed desorption spectra of 4-100% carbon monoxide monolayer coverage. The adstates had fixed activation energies of desorption (22.5-32.6 kcal/mole) over the entire coverage range. Rates of formation and populations were derived. The chemisorption was modeled by a Hinshelwood-type expression which allowed for site creation and suggested that adsorbed molecules are sufficiently mobile during desorption heating to fill ordered states of minimum energy and that chemisorption into these states is noncompetitive and determined by the surface. Spectra, diagrams, graphs, tables, and 49 references.

  12. Convergence of quasiparticle self-consistent GW calculations of transition metal monoxides

    OpenAIRE

    Das, Suvadip; Coulter, John E.; Manousakis, Efstratios

    2014-01-01

    Finding an accurate ab initio approach for calculating the electronic properties of transition metal oxides has been a problem for several decades. In this paper, we investigate the electronic structure of the transition metal monoxides MnO, CoO, and NiO in their undistorted rock-salt structure within a fully iterated quasiparticle self-consistent GW (QPscGW) scheme. We study the convergence of the QPscGW method, i.e., how the quasiparticle energy eigenvalues and wavefunctions converge as a f...

  13. Influence of carbon monoxide to the surface layer of uranium metal and its oxides

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-09-01

    The surface structures of uranium metal and triuranium octaoxide (U 3 O 8 ) and the influence of carbon monoxide to the surface layers have been studied by X-ray photoelectron spectroscopy (XPS). After exposure to carbon monoxide, contents of oxygen in the surface oxides of uranium metal and U 3 O 8 are decreased and O/U ratios decrease 7.2%, 8.0% respectively. The investigation indicated the surface layers of uranium metal and its oxides were forbidden to further oxidation in the atmosphere of carbon monoxide. (11 refs., 9 figs., 2 tabs.)

  14. Carbon Monoxide Hazards from Small Gasoline Powered Engines

    Science.gov (United States)

    ... DHHS (NIOSH) Publication No. 96-118 (1996) Describes health effects and current standards and guidelines relating to carbon monoxide, as well as recommendations for workers, employers, and manufacturers regarding small gasoline powered engine ...

  15. MODELLING OF CARBON MONOXIDE AIR POLLUTION IN LARG CITIES BY EVALUETION OF SPECTRAL LANDSAT8 IMAGES

    Directory of Open Access Journals (Sweden)

    M. Hamzelo

    2015-12-01

    Full Text Available Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS , spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  16. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    Science.gov (United States)

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-11-01

    Small-size (carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction.

  17. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    International Nuclear Information System (INIS)

    Mu, Jiali; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-01-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl 2 catalyst and PdCl 2 catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl 2 catalyst) was more thermally stable than PK (PdCl 2 catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by 1 H NMR, 13 C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E k ) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E k values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol −1 . Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK

  18. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Jiali, E-mail: jiaqm411@163.com; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-03-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl{sub 2} catalyst and PdCl{sub 2} catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl{sub 2} catalyst) was more thermally stable than PK (PdCl{sub 2} catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by {sup 1}H NMR, {sup 13}C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E{sub k}) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E{sub k} values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol{sup −1}. Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK.

  19. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker a...

  20. Carbon monoxide reduces near-infrared spectroscopy determined 'total' hemoglobin

    DEFF Research Database (Denmark)

    Niemann, Mads J; Sørensen, Henrik; Siebenmann, Christoph

    2017-01-01

    with CO (1.5 mL kg-1) was added to the circuit. Two NIRS systems (NIRO-200NX and INVOS-5100) assessed ScO2 as the ratio of oxygenated to deoxygenated hemoglobin, while venous blood samples were analyzed for carboxyhemoglobin (COHb). After CO/O2 rebreathing COHb increased to 8.7% (IQR; 7.9-9.4; p = .004...... to normoxia (68.9 ± 6.9%; p hemoglobin decreased (by 19.7 μM (median; IQR 2.8-34.8; p = .016) and 37.3 μM (30.8-46.6; p = .004), respectively) during inhalation of CO/O2 compared...... to inhalation of O2. Therefore, NIRO-200NX determined 'total' hemoglobin (sum of O2Hb and HHb) decreased (by 62.1 μM; 44.5-78.2; p = .001). In conclusion, exposure to CO did not increase MCAVmean, and neither NIRO-200NX nor INVOS-5100 detected a change in ScO2 when CO was added to inhalation of oxygen...

  1. CT and clinical patterns in suicidal carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-12-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications.

  2. Kinetics of heterogeneous catalysis oxidation of carbon monoxide

    International Nuclear Information System (INIS)

    Khawaja, Y.; Sadiq, A.

    1987-10-01

    An irreversible kinetic surface-reaction model, based upon the reaction of carbon monoxide nd oxygen on a catalyst surface is investigated by means of Monte Carlo simulation. The adsorbed molecules/atoms on the surface undergo both first and second order kinetic phase transitions. The first order transition is found to occur at x/sub/co=x/sub/2=0.5255 with an error bar of 0.0003, where x/sub/co is the concentration of carbon monoxide in the gas phase. The time evolution of this catalytic reaction is studied both analytically and by computer simulation. Slightly above x/sub/2, the oxygen coverage relaxation time for the oxygen is found to diverage as the inverse of 3.54 times the absolute of the difference of x/sub/2 and x/sub/co. (orig./A.B.)

  3. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Science.gov (United States)

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  4. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Science.gov (United States)

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  5. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    Science.gov (United States)

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  6. CT and clinical patterns in suicidal carbon monoxide

    International Nuclear Information System (INIS)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-01-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications. (orig.) [de

  7. Environmental tobacco smoke exposure among non-smoking waiters: measurement of expired carbon monoxide levels

    Directory of Open Access Journals (Sweden)

    Ronaldo Laranjeira

    2000-07-01

    Full Text Available CONTEXT: Exposure to environmental tobacco smoke is a health risk that is of concern to patrons and of particular concern to employees of restaurants and bars. OBJECTIVE: To assess environmental tobacco smoke exposure (using expired carbon monoxide levels in non-smoking waiters before and after a normal day's shift and to compare pre-exposure levels with non-smoking medical students. DESIGN: An observational study. SETTING: Restaurants with more than 50 tables or 100 places in São Paulo. SUBJECTS: 100 non-smoking restaurant waiters and 100 non-smoking medical students in São Paulo, Brazil. MAIN MEASUREMENTS: Levels of expired carbon monoxide, measured with a Smokerlyser (Bedfont EC 50 Scientific, before and after a normal day's work. RESULTS: Waiters' pre-exposure expired carbon monoxide levels were similar to those of medical students, but after a mean of 9 hours exposure in the workplace, median levels more than doubled (2.0 ppm vs. 5.0 ppm, P <0.001. Post-exposure carbon monoxide levels were correlated with the number of tables available for smokers (Kendall's tau = 0.2, P <0.0001. CONCLUSIONS: Exposure to environmental tobacco smoke is the most likely explanation for the increase in carbon monoxide levels among these non-smoking waiters. These findings can be used to inform the ongoing public health debate on passive smoking.

  8. Assessment of exposure to carbon monoxide group of firefighters from fire fighting and rescue units

    Directory of Open Access Journals (Sweden)

    Jadwiga Lembas-Bogaczyk

    2011-03-01

    Full Text Available Firemen threat during fire burning of chemical substances indicated presence of carbon monoxide (CO in all cases. Carbon monoxide causes death of fire. Inhaled through respiratory system, links with hemoglobin, thus blocking transport and distribution of oxygen in the body. This leads to tissue anoxia, which is a direct threat to firefighters’ life. The purpose of this study was to assess the exposure to carbon monoxide of participating firefighters extinguishing fire. Estimation of carbon monoxide quantity absorbed by firefighters was isolated in a group of 40 firefighters from Fire Extinguishing and Rescue Unit of State Fire in Nysa. The study was conducted by measuring carbon monoxide in exhaled air. For measurement of carbon monoxide concentration in exhaled air Micro CO meter was used. Results were demonstrated separately for nonsmokers (n425 and smokers (n415. Mean COHb[%] levels in nonsmokers, measured prior the rescue action was 0,3950,3% and increased statistically significant after the action to 0,6150,34%, while in the group smokers, this level was 2,1750,64% before the action and increased insignificantly after the action to 2,3350,63%. The average COHb level in the same groups before and after exercise, was respectively: for nonsmokers prior to exercise was 0,4850,28% and after exercise decreased statistically significant to 0,3050,27%. In the group of smokers before exercise was 2,2350,61% and decreased statistically significant up to 1,5450,71%. It was no difference between the group of age and time of employment.

  9. Study on the influence of carbon monoxide to the surface oxide layer of uranium metal

    International Nuclear Information System (INIS)

    Wang Xiaolin; Duan Rongliang; Fu Yibei; Xie Renshou; Zuo Changming; Zhao Chunpei; Chen Hong

    1997-01-01

    The influence of carbon monoxide to the surface oxide layer of uranium metal has been studied by X-ray photoelectron spectroscopy (XPS) and gas chromatography (GC). Carbon monoxide adsorption on the oxide layer resulted in U4f peak shifting to the lower binding energy. The content of oxygen in the oxide is decreased and the atomic ratio (O/U) is decreased by 7.2%. The amount of carbon dioxide in the atmosphere after the surface reaction is increased by 11.0%. The investigation indicates that the surface layer can prevent the further oxidation uranium metal in the atmosphere of carbon monoxide

  10. Hydrothermal Synthesis of Pt-, Fe-, and Zn-doped SnO2 Nanospheres and Carbon Monoxide Sensing Properties

    Directory of Open Access Journals (Sweden)

    Weigen Chen

    2013-01-01

    Full Text Available Pure and M-doped (M = Pt, Fe, and Zn SnO2 nanospheres were successfully synthesized via a simple and facile hydrothermal method and characterized by X-ray powder diffraction, field-emission scanning electron microscopy, and energy dispersive spectroscopy. Chemical gas sensors were fabricated based on the as-synthesized nanostructures, and carbon monoxide sensing properties were systematically measured. Compared to pure, Fe-, and Zn-doped SnO2 nanospheres, the Pt-doped SnO2 nanospheres sensor exhibits higher sensitivity, lower operating temperature, more rapid response and recovery, better stability, and excellent selectivity. In addition, a theoretical study based on the first principles calculation was conducted. All results demonstrate the potential of Pt dopant for improving the gas sensing properties of SnO2-based sensors to carbon monoxide.

  11. Production of Ethylene and Carbon Monoxide by Microorganisms

    Science.gov (United States)

    T. H. Filer; L. R. Brown; S. Brown-Sarobot; S. Martin

    1984-01-01

    Various quantities of ethylene and carbon monoxide were produced on PDA by Fusicladium effusum, Pestilotia nucicola, Alternaria tenuis, and Fusarium oxysporum subcultured from diseased pecan shucks. Repeated subculturing of these fungi on potato dextrose broth supplemented with iron powder produced ethylene. The production of...

  12. Study of photoionization and dissociative photoionization of carbon monoxide from ionization threshold to 38 eV by using synchrotron radiation

    International Nuclear Information System (INIS)

    Zhao, Yujie; Cao, Maoqi; Li, Yuquan; Shan, Xiaobin; Liu, Fuyi; Sheng, Liusi; Li, Li; Liu, Wanfang

    2014-01-01

    Highlights: • The high resolution photoionization spectrum of carbon monoxide has been investigated using tunable synchrotron radiation. • This work has investigated comprehensively almost all kinds of photo excitation processes of CO in wide photon region. • The mechanisms of photoionization and dissociative photoionization of CO have been researched in detail. - Abstract: The vacuum-ultraviolet photoionization and dissociative photoionization of carbon monoxide in a region 14–38 eV have been investigated with time-of-flight (TOF) photoionization mass spectrometry (PIMS) using tunable synchrotron radiation (SR). The adiabatic ionization energy (IE) of carbon monoxide and appearance energies (AE) for its fragment ions in different states are determined by measurements of photoionization efficiency spectra (PIES). Ab initio calculations have been performed to investigate the reaction mechanism of dissociative photoionization of carbon monoxide. On the basis of experimental and predicted theoretical results, the mechanisms of photoionization and dissociative photoionization of molecular CO are discussed, and sixteen dissociative photoionization processes are proposed. The equilibrium geometries and harmonic vibrational frequencies of CO molecule, and its parent cation were calculated by using MP2 (full) method. The differences of configurations between them are also discussed on the basis of theoretical calculations. According to our results, the experimental IE of CO molecule, and dissociation energies (E d ) of possible dissociative channels are in reasonable agreement with the calculated values of the proposed photodissociation channels

  13. Multum in Parvo: Explorations with a Small Bag of Carbon Dioxide

    Directory of Open Access Journals (Sweden)

    EJM Campbell

    2001-01-01

    Full Text Available A collection of 12 papers published between 1957 and 1972 are revisited. The papers had a common theme of the use of rebreathing carbon dioxide and explored a variety of topics in respiratory physiology. The first study established a method for the noninvasive and indirect estimation of arterial carbon dioxide pressure that was suitable for the routine clinical monitoring of respiratory failure and whose clinical utility remains to this day, but which also provided observations that were the stimulus for the studies that followed. The rate of rise in the partial pressure of carbon dioxide (PCO2 during rebreathing led to an analysis of body carbon dioxide storage capacity. Knowledge of carbon dioxide storage led to a method for quantifying lactate production in exercise without the need for blood sampling. The changes in ventilation that accompanied the increase in PCO2 provided the basis for a rapid method for measuring aspects of breathing control (Read's method, which was later modified to measure the ventilatory response to hypoxia. The physiology of breath-holding was explored through observations of the fall in breath-holding time as PCO2 climbed. Rebreathing also allowed increases in voluntary ventilation to be achieved without the development of alkalosis, leading to studies of maximal voluntary ventilation and respiratory muscle fatigue. Equilibration of PCO2 during rebreathing was used to measure mixed venous PCO2 during exercise and develop an integrated approach to the physiology of exercise in health and disease; alveolar-arterial disequilibrium in PCO2 during exercise was uncovered. Equilibration of PCO2, as well as PO2, during rebreathing of carbon dioxide and nitrogen gas mixtures showed different time courses of venous gases at the onset of exercise. Starting with the rebreathing of carbon dioxide in oxygen mixtures in a small rubber bag, an astonishing range of topics in respiratory physiology was explored, with observations

  14. Ambient carbon monoxide and cardiovascular mortality: a nationwide time-series analysis in 272 cities in China.

    Science.gov (United States)

    Liu, Cong; Yin, Peng; Chen, Renjie; Meng, Xia; Wang, Lijun; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Kan, Haidong; Zhou, Maigeng

    2018-01-01

    Evidence of the acute health effects of ambient carbon monoxide air pollution in developing countries is scarce and mixed. We aimed to evaluate short-term associations between carbon monoxide and daily cardiovascular disease mortality in China. We did a nationwide time-series analysis in 272 major cities in China from January, 2013, to December, 2015. We extracted daily cardiovascular disease mortality data from China's Disease Surveillance Points system. Data on daily carbon monoxide concentrations for each city were obtained from the National Urban Air Quality Real-time Publishing Platform. City-specific associations between carbon monoxide concentrations and daily mortality from cardiovascular disease, coronary heart disease, and stroke were estimated with over-dispersed generalised linear models. Bayesian hierarchical models were used to obtain national and regional average associations. Exposure-response association curves and potential effect modifiers were evaluated. Two-pollutant models were fit to evaluate the robustness of the effects of carbon monoxide on cardiovascular mortality. The average annual mean carbon monoxide concentration in these cities from 2013 to 2015 was 1·20 mg/m 3 , ranging from 0·43 mg/m 3 to 2·45 mg/m 3 . For a 1 mg/m 3 increase in average carbon monoxide concentrations on the present day and previous day (lag 0-1), we observed significant increments in mortality of 1·12% (95% posterior interval [PI] 0·42-1·83) from cardiovascular disease, 1·75% (0·85-2·66) from coronary heart disease, and 0·88% (0·07-1·69) from stroke. These associations did not vary substantially by city, region, and demographic characteristics (age, sex, and level of education), and the associations for cardiovascular disease and coronary heart disease were robust to the adjustment of criteria co-pollutants. We did not find a threshold below which carbon monoxide exposure had no effect on cardiovascular disease mortality. This analysis is, to our

  15. Optimization of mass flow rate in RGTT200K coolant purification for Carbon Monoxide conversion process

    International Nuclear Information System (INIS)

    Sumijanto; Sriyono

    2016-01-01

    Carbon monoxide is a species that is difficult to be separated from the reactor coolant helium because it has a relatively small molecular size. So it needs a process of conversion from carbon monoxide to carbondioxide. The rate of conversion of carbon monoxide in the purification system is influenced by several parameters including concentration, temperature and mass flow rate. In this research, optimization of the mass flow rate in coolant purification of RGTT200K for carbon monoxide conversion process was done. Optimization is carried out by using software Super Pro Designer. The rate of reduction of reactant species, the growth rate between the species and the species products in the conversion reactions equilibrium were analyzed to derive the mass flow rate optimization of purification for carbon monoxide conversion process. The purpose of this study is to find the mass flow rate of purification for the preparation of the basic design of the RGTT200K coolant helium purification system. The analysis showed that the helium mass flow rate of 0.6 kg/second resulted in an un optimal conversion process. The optimal conversion process was reached at a mass flow rate of 1.2 kg/second. A flow rate of 3.6 kg/second – 12 kg/second resulted in an ineffective process. For supporting the basic design of the RGTT200K helium purification system, the mass flow rate for carbon monoxide conversion process is suggested to be 1.2 kg/second. (author)

  16. Cardiological aspects of carbon monoxide poisoning.

    Science.gov (United States)

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  17. Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial.

    Science.gov (United States)

    Ocak, Tarik; Tekin, Erdal; Basturk, Mustafa; Duran, Arif; Serinken, Mustafa; Emet, Mucahit

    2016-11-01

    There is a lack of specificity of the analgesic agents used to treat headache and underlying acute carbon monoxide poisoning. To compare effectiveness of "oxygen alone" vs "metoclopramide plus oxygen" vs "metamizole plus oxygen" therapy in treating carbon monoxide-induced headache. A prospective, multicenter, double-blind, controlled trial. Three emergency departments in Turkey. Adult carbon monoxide poisoning patients with headache. A total of 117 carbon monoxide-intoxicated patients with headache were randomized into 3 groups and assessed at baseline, 30 minutes, 90 minutes, and 4 hours. The primary outcome was patient-reported improvement rates for headache. Secondary end points included nausea, need for rescue medication during treatment, and reduction in carboxyhemoglobin levels. During observation, there was no statistical difference between drug type and visual analog scale score change at 30 minutes, 90 minutes, or 4 hours, for either headache or nausea. No rescue medication was needed during the study period. The reduction in carboxyhemoglobin levels did not differ among the 3 groups. The use of "oxygen alone" is as efficacious as "oxygen plus metoclopramide" or "oxygen plus metamizole sodium" in the treatment of carbon monoxide-induced headache. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Analysis of patients presenting to the emergency department with carbon monoxide intoxication

    Directory of Open Access Journals (Sweden)

    Selim Yurtseven

    2015-12-01

    Full Text Available Objectives: Carbon monoxide is a potentially fatal form of poisoning. The exact incidence is unclear, due to cases being undiagnosed or reported as fewer than the real number. Hyperbaric oxygen therapy (HBOT is of proven efficacy in the treatment of CO intoxication.The purpose of this study was to describe the general characteristics of carbon monoxide (CO intoxications presenting to the emergency department and to investigate troponin I values and the effectiveness of hyperbaric oxygen therapy (HBOT in these patients. Material and methods: Patients presenting to the emergency department with CO intoxication over one year and patients with such intoxications receiving HBOT were examined retrospectively. Results: One hundred seventy-one patients were included; 140 (81.9% were poisoned by stoves, 18 (10.5% by hot water boilers and 10 in (5.8% by fires. COHb levels were normal in 49 of the 163 patients whose values were investigated, and were elevated in 114 patients. Mean COHb value was 16.6. Troponin I values were investigated in 112 patients. These were normal in 86 patients and elevated in 26. Mean troponin I value was 0.38 ng/ml. One hundred twenty-three of the 171 patients in the study were discharged in a healthy condition after receiving normobaric oxygen therapy, while 48 patients received HBOT. Forty-two (87.5% of the patients receiving HBOT were discharged in a healthy condition while sequelae persisted in five (10.4%. One patient died after 15 session of HBOT. Conclusion: Although elevated carboxyhemoglobin confirms diagnosis of CO intoxication, normal levels do not exclude it. Troponin I levels may rise in CO intoxication. No significant relation was observed between carboxyhemoglobin and receipt of HBOT. A significant correlation was seen, however, between troponin I levels and receipt of HBOT. Keywords: Carbon monoxide intoxication, Hyperbaric oxygen, Troponin I, Echocardiography

  19. Cyclic process for producing methane from carbon monoxide with heat removal

    Science.gov (United States)

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  20. Carbon monoxide and respiratory symptoms in young adult passive smokers: A pilot study comparing waterpipe to cigarette

    Directory of Open Access Journals (Sweden)

    Rouba Zeidan

    2014-08-01

    Full Text Available Objectives: Studies have correlated second hand smoke (SHS with many diseases, especially respiratory effects. The goal of this study was to measure the impact of SHS on the respiratory symptoms and exhaled carbon monoxide. Material and Methods: The study population consisted of 50 young workers in restaurants serving waterpipes, 48 university students who sit frequently in the university cafeteria where cigarette smoking is allowed and 49 university students spending time in places where smoking is not allowed. Subjects completed questionnaires on socio-demographic characteristics, respiratory symptoms and exposure to SHS. Exhaled carbon monoxide levels were measured. ANOVA and Chi-square tests were used when applicable as well as linear and logistic regression analysis. Results: Exposure to cigarette smoke in university (adjusted odds ratio (ORa = 6.06 and occupational exposure to waterpipe smoke (ORa = 7.08 were predictors of chronic cough. Being married (ORa = 6.40, living near a heavy traffic road (ORa = 9.49 or near a local power generator (ORa = 7.54 appeared responsible for chronic sputum production. Moreover, predictors of chronic allergies were: being male (ORa = 7.81, living near a local power generator (ORa = 5.52 and having a family history of chronic respiratory diseases (ORa = 17.01. Carbon monoxide levels were augmented by the number of weekly hours of occupational exposure to waterpipe smoke (β = 1.46 and the number of daily hours of exposure to cigarette smoke (β = 1.14. Conclusions: In summary, young non-smoker subjects demonstrated more chronic cough and elevated carbon monoxide levels when exposed to SHS while the effect of waterpipe was even more evident.

  1. Digit and letter alexia in carbon monoxide poisoning

    Institute of Scientific and Technical Information of China (English)

    Qingyu Shen; Xiaoming Rong; Rui Pan; Ying Peng; Wei Peng; Yamei Tang

    2012-01-01

    This study examined a 24-year-old patient with delayed encephalopathy, who was admitted to hospital with complaints of headache and visual impairment 1 week after acute carbon monoxide poisoning. The results of a visual field assessment, electroencephalography and head magnetic resonance imaging indicated damage to the cerebral cortex. After a 2-week treatment period, the patient had recovered from the visual impairment, but exhibited digit- and letter-reading difficulty. The Chinese aphasia battery and the number and letter battery supplement were conducted. The results revealed that the patient exhibited digit and letter alexia, while the ability to read Chinese characters was preserved. In contrast, the patient exhibited a deficit in Chinese character writing, while number and letter writing remained intact. Following treatment, reading and writing ability was improved and electroencephalographic abnormalities were ameliorated. Overall, our experimental findings demonstrated that delayed encephalopathy following acute carbon monoxide poisoning was characterized by digit and letter alexia.

  2. Serum bilirubin value predicts hospital admission in carbon monoxide-poisoned patients. Active player or simple bystander?

    Directory of Open Access Journals (Sweden)

    Gianfranco Cervellin

    Full Text Available OBJECTIVES: Although carbon monoxide poisoning is a major medical emergency, the armamentarium of recognized prognostic biomarkers displays unsatisfactory diagnostic performance for predicting cumulative endpoints. METHODS: We performed a retrospective and observational study to identify all patients admitted for carbon monoxide poisoning during a 2-year period. Complete demographical and clinical information, along with the laboratory data regarding arterial carboxyhemoglobin, hemoglobin, blood lactate and total serum bilirubin, was retrieved. RESULTS: The study population consisted of 38 poisoned patients (23 females and 15 males; mean age 39±21 years. Compared with discharged subjects, hospitalized patients displayed significantly higher values for blood lactate and total serum bilirubin, whereas arterial carboxyhemoglobin and hemoglobin did not differ. In a univariate analysis, hospitalization was significantly associated with blood lactate and total serum bilirubin, but not with age, sex, hemoglobin or carboxyhemoglobin. The diagnostic performance obtained after combining the blood lactate and total serum bilirubin results (area under the curve, 0.90; 95% CI, 0.81-0.99; p<0.001 was better than that obtained for either parameter alone. CONCLUSION: Although it remains unclear whether total serum bilirubin acts as an active player or a bystander, we conclude that the systematic assessment of bilirubin may, alongside lactate levels, provide useful information for clinical decision making regarding carbon monoxide poisoning.

  3. The indigenous Sea Gypsy divers of Thailand's west coast: measurement of carbon monoxide in the breathing air.

    Science.gov (United States)

    Gold, D; Geater, A; Aiyarak, S; Juengpraert, W

    1999-07-01

    Approximately 400 indigenous divers live and work on Thailand's west coast. They dive with surface supplied air from primitive compressor units mounted on open boats which measure from seven to 11 meters in length. It was suspected that carbon monoxide was present in the breathing air of at least the gasoline-driven compressor units. To determine the presence of carbon monoxide gas in the breathing air, compressed air from the compressor was pumped through the diver air supply hose through a plenum (monitoring) chamber established on the boat. After a compressor warm-up of 15 minutes, the diving air was measured with the boat at eight different bearings to the wind, each 45 degrees apart at intervals of five minutes. Three of the four gasoline-driven compressor units tested showed presence of carbon monoxide in the breathing air. One diesel-driven unit showed a very low concentration of carbon monoxide (3-4 ppm) and six diesel-driven units showed no detectable carbon monoxide. Although not tested, diesel exhaust emissions could also enter the breathing air by the same route. A locally made modification to the compressor air intake was designed and successfully tested on one gasoline-driven compressor unit. An information sheet on the hazards of carbon monoxide as well as on the modification has been developed for distribution among the villages.

  4. Ethylene and Carbon Monoxide Production by Septoria musiva

    Science.gov (United States)

    S. Brown-Skrobot; L. R. Brown; T. H. Filer

    1984-01-01

    An investigation into the mechanism by which Septoria musiva causes the premature defoliation of cottonwood trees was undertaken. Gas-chromatograpic analysis of the atmosphere overlying the original culture indicated that this fungus produced significant quantities of ethylene and carbon monoxide. Subcultures failed to produce either gas on a variety...

  5. Pathways and bioenergetics of anaerobic carbon monoxide fermentation

    NARCIS (Netherlands)

    Diender, Martijn; Stams, Fons; Machado de Sousa, Diana

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the

  6. Interactions of carbon monoxide and hemoglobin at high altitude

    Energy Technology Data Exchange (ETDEWEB)

    Collier, C.R. (Univ. of Southern California Medical Center, Los Angeles); Goldsmith, J.R.

    1983-01-01

    The health risks to U.S. populations who are exposed to ambient carbon monoxide and live at altitudes (such as Denver, Salt Lake City, and Albuquerque) were evaluated using a set of mathematical models. The assumption that a given increase in carboxyhemoglobin would require a more stringent volumetric air quality standard was tested. The results using the model predict that the 8-h or 1-h standards adopted for sea level condition need not be altered to protect individuals against health risks at altitude, if the standards are in volumetric terms. They would need to be reduced if the standards are left in gravimetric terms. If the guideline is to be based on a given decrement of oxygen tension, many other variables must be specified, but expected differences in ambient carbon monoxide have a small impact compared to the effect of altitude itself.

  7. Accidental carbon monoxide poisoning during yagya for faith healing--a case report.

    Science.gov (United States)

    Behera, C; Millo, T M; Jaiswal, A; Dogra, T D

    2013-03-01

    A 20-year-old female and a 45-year-old male were found lying dead on the floor with frothand vomitus stain present over mouth, nose and face in a closed room. An earthen bowl with incomplete burnt woods, flowers, food materials, agarbati, etc, was also found lying near the body of the two deceased. The cause of death, established by autopsy and toxicological examination was carbon monoxide poisoning in both victims. The source of carbon monoxide was incomplete burnt woods used for yagya during puja (a faith healing practice) for bearing children.

  8. First-Principles Investigations on Europium Monoxide

    KAUST Repository

    Wang, Hao

    2011-05-01

    Europium monoxide is both an insulator and a Heisenberg ferromagnet (Tc=69 K). In the present thesis, the author has investigated the electronic structure of different types of EuO by density functional theory. The on-site Coulomb interaction of the localized Eu 4f and 5d electrons, which is wrongly treated in the standard generalized gradient approximation method, is found to be crucial to obtain the correct insulating ground state as observed in experiments. Our results show that the ferromagnetism is stable under pressure, both hydrostatic and uniaxial. For both types of pressure an insulator-metal transition is demonstrated. Moreover, the experimentally observed insulator-metal transition in oxygen deficient and gadolinium-doped EuO is reproduced in our calculations for impurity concentrations of 6.25% and 25%. Furthermore, a 10- layer EuO thin film is theoretically predicted to be an insulator with a narrow band gap of around 0.08 eV, while the Si/EuO interface shows metallic properties with the Si and O 2p as well as Eu 5d bands crossing the Fermi level.

  9. [Carbon monoxide poisoning by a heating system].

    Science.gov (United States)

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  10. Absorption of nicotine and carbon monoxide from passive smoking under natural conditions of exposure.

    Science.gov (United States)

    Jarvis, M J; Russell, M A; Feyerabend, C

    1983-01-01

    Seven non-smokers were exposed to tobacco smoke under natural conditions for two hours in a public house. Measures of nicotine and cotinine in plasma, saliva, and urine and expired air carbon monoxide all showed reliable increases. The concentrations of carbon monoxide and nicotine after exposure averaged 15.7% and 7.5% respectively of the values found in heavy smokers. Although the increase in expired air carbon monoxide of 5.9 ppm was similar to increases in smokers after a single cigarette, the amount of nicotine absorbed was between a tenth and a third of the amount taken in from one cigarette. Since this represented a relatively extreme acute natural exposure, any health risks of passive smoking probably depend less on quantitative factors than on qualitative differences between sidestream and mainstream smoke. PMID:6648864

  11. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kaminaga, Kenichi; Sei, Ryosuke [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan); Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hayashi, Kouichi [Department of Environmental and Materials Engineering, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Happo, Naohisa [School of Information Sciences, Hiroshima City University, Hiroshima 731-3194 (Japan); Tajiri, Hiroo [Japan Synchrotron Radiation Research Institute (JASRI)/SPring-8, Sayo 679-5198 (Japan); Oka, Daichi; Fukumura, Tomoteru, E-mail: tomoteru.fukumura.e4@tohoku.ac.jp [Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hasegawa, Tetsuya [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan)

    2016-03-21

    Rare earth oxides are usually widegap insulators like Y{sub 2}O{sub 3} with closed shell trivalent rare earth ions. In this study, solid phase rock salt structure yttrium monoxide, YO, with unusual valence of Y{sup 2+} (4d{sup 1}) was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO has been recognized as gaseous phase in previous studies. In contrast with Y{sub 2}O{sub 3}, YO was dark-brown colored and narrow gap semiconductor. The tunable electrical conductivity ranging from 10{sup −1} to 10{sup 3} Ω{sup −1 }cm{sup −1} was attributed to the presence of oxygen vacancies serving as electron donor. Weak antilocalization behavior observed in magnetoresistance indicated significant role of spin-orbit coupling as a manifestation of 4d electron carrier.

  12. An operando FTIR spectroscopic and kinetic study of carbon monoxide pressure influence on rhodium-catalyzed olefin hydroformylation.

    Science.gov (United States)

    Kubis, Christoph; Sawall, Mathias; Block, Axel; Neymeyr, Klaus; Ludwig, Ralf; Börner, Armin; Selent, Detlef

    2014-09-08

    The influence of carbon monoxide concentration on the kinetics of the hydroformylation of 3,3-dimethyl-1-butene with a phosphite-modified rhodium catalyst has been studied for the pressure range p(CO)=0.20-3.83 MPa. Highly resolved time-dependent concentration profiles of the organometallic intermediates were derived from IR spectroscopic data collected in situ for the entire olefin-conversion range. The dynamics of the catalyst and organic components are described by enzyme-type kinetics with competitive and uncompetitive inhibition reactions involving carbon monoxide taken into account. Saturation of the alkyl-rhodium intermediates with carbon monoxide as a cosubstrate occurs between 1.5 and 2 MPa of carbon monoxide pressure, which brings about a convergence of aldehyde regioselectivity. Hydrogenolysis of the acyl intermediate is fast at 30 °C and low pressure of p(CO)=0.2 MPa, but is of minus first order with respect to the solution concentration of carbon monoxide. Resting 18-electron hydrido and acyl complexes that correspond to early and late rate-determining states, respectively, coexist as long as the conversion of the substrate is not complete. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    Science.gov (United States)

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  14. Acute wood or coal exposure with carbon monoxide intoxication induces sister chromatid exchange

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, S.; Vatansever, S.; Cefle, K.; Palanduz, S.; Guler, K.; Erten, N.; Erk, O.; Karan, M.A.; Tascioglu, C. [University of Istanbul, Istanbul (Turkey). Istanbul Faculty of Medicine

    2002-07-01

    The object of this study was to investigate the genotoxic effect of acute overexposure to combustion products originating from coal or wood stoves in patients presenting with acute carbon monoxide intoxication. The authors analyzed the frequency of sister chromatid exchange and the carboxyhemoglobin concentration in 20 consecutive patients without a history of smoking or drug use who had been treated in the Emergency Care Unit of Istanbul Medical Faculty due to acute carbon monoxide intoxication. All of these cases were domestic accidents due to dysfunctioning coal or wood stoves. The results were compared with a control group of 20 nonsmoking, nondrug-using healthy individuals matched for age, sex, and absence of other chemical exposure. It was concluded that acute exposure to combustion products of wood or coal is genotoxic to DNA. Potential causes of genotoxicity include known mutagenic compounds present in coal or wood smoke and ash, oxygen radicals formed during combustion, as well as hypoxic and reperfusion injury mechanisms initiated by carbon monoxide intoxication.

  15. Mixing ratios of carbon monoxide in the troposphere

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Steele, L.P. (Univ. of Colorado, Boulder (United States)); Tans, P.P. (NOAA, Boulder, CO (United States))

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  16. Influence of cation size and surface coverage upon the infrared spectrum of carbon monoxide

    OpenAIRE

    Huang, Jimin

    1991-01-01

    Adsorbed carbon monoxide is utilized as a double layer probe molecule because of its strong absorption in infrared region and because of the high sensitivity of the carbon-oxygen bond to changes in the environment local to the electrode surface. Potential Difference Infrared Spectroscopy was used to investigate the structural behavior of CO adsorbed on a platinum electrode. Carbon monoxide was found to be exclusively linear-bonded on platinum electrode in the presence of tetran...

  17. Carbon monoxide oxidation using Zn-Cu-Ti hydrotalcite-derived ...

    Indian Academy of Sciences (India)

    Multioxide catalysts of zinc, copper and titanium with different ratios obtained from layered double hydroxide (LDH) precursors were used in the oxidation of carbon monoxide. The catalysts were characterized by energy-dispersive X-ray spectrometry, X-ray diffraction, thermal analyses (TG, DTG and DTA) and scanning ...

  18. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    Science.gov (United States)

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  19. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008; Campagne de prevention des intoxications au monoxyde de carbone : automne-hiver 2007-2008

    Energy Technology Data Exchange (ETDEWEB)

    Lefebvre, B.; Chabot, L.; Gratton, J. [Direction de sante publique de Montreal, Montreal, PQ (Canada); Lacoursiere, D. [Quebec Ministere de la Sante et des Services sociaux du Quebec, Quebec, PQ (Canada)

    2009-07-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  20. Sensorineural Hearing Loss following Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Joseph P. Pillion

    2012-01-01

    Full Text Available A case study is presented of a 17-year-old male who sustained an anoxic brain injury and sensorineural hearing loss secondary to carbon monoxide poisoning. Audiological data is presented showing a slightly asymmetrical hearing loss of sensorineural origin and mild-to-severe degree for both ears. Word recognition performance was fair to poor bilaterally for speech presented at normal conversational levels in quiet. Management considerations of the hearing loss are discussed.

  1. Four deaths due to carbon monoxide poisoning in car washes.

    Science.gov (United States)

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  2. Retrieval of tropospheric carbon monoxide for the MOPITT experiment

    Science.gov (United States)

    Pan, Liwen; Gille, John C.; Edwards, David P.; Bailey, Paul L.; Rodgers, Clive D.

    1998-12-01

    A retrieval method for deriving the tropospheric carbon monoxide (CO) profile and column amount under clear sky conditions has been developed for the Measurements of Pollution In The Troposphere (MOPITT) instrument, scheduled for launch in 1998 onboard the EOS-AM1 satellite. This paper presents a description of the method along with analyses of retrieval information content. These analyses characterize the forward measurement sensitivity, the contribution of a priori information, and the retrieval vertical resolution. Ensembles of tropospheric CO profiles were compiled both from aircraft in situ measurements and from chemical model results and were used in retrieval experiments to characterize the method and to study the sensitivity to different parameters. Linear error analyses were carried out in parallel with the ensemble experiments. Results of these experiments and analyses indicate that MOPITT CO column measurements will have better than 10% precision, and CO profile measurement will have approximately three pieces of independent information that will resolve 3-5 tropospheric layers to approximately 10% precision. These analyses are important for understanding MOPITT data, both for application of data in tropospheric chemistry studies and for comparison with in situ measurements.

  3. Determining the diagnostic value of endogenous carbon monoxide in Chronic Obstructive Pulmonary Disease exacerbations

    International Nuclear Information System (INIS)

    Dogan, N. O.; Corbacioglu, S. K.; Bildik, F.; Kilicaslan, I.; Hakoglu, O.; Gunaydin, G. P.; Cevik, Y.; Ulker, V.; Gokcen, E.

    2014-01-01

    Objective: To determine whether endogenous carbon monoxide levels in exacerbations of Chronic Obstructive Pulmonary Disease patients were higher compared to healthy individuals and to investigate alteration of carbon monoxide levels across the three different severity stages of Global Initiative for Chronic Obstructive Lung Disease criteria related to Chronic Obstructive Pulmonary Disease exacerbations. Methods: The prospective study was conducted from January to March 2011 at two medical institutions in Ankara, Turkey, and comprised patients of acute Chronic Obstructive Pulmonary Disease exacerbations. The severity of the exacerbations was based on the Global Initiative for Chronic Obstructive Lung Disease criteria. Patients with active tobacco smoking, suspicious carbon monoxide poisoning and uncertain diagnosis were excluded. healthy control subjects who did not have any comorbid diseases and smoking habitus were also enrolled to compare the differences between carboxyhaemoglobin levels A two-tailed Mann-Whitney U test with Bonferroni correction was done following a Kruskal-Wallis test for statistical purposes. Results: There were 90 patients and 81 controls in the study. Carboxyhaemoglobin levels were higher in the patients than the controls (p<0.001). As for the three severity stages, Group 1 had a median carboxyhaemoglobin of 1.6 (0.95-2.00). The corresponding levels in Group 2 (1.8 (1.38-2.20)) and Group 3 (1.9 (1.5-3.0)) were higher than the controls (p<0.001 and p<0.005 respectively). No statistically significant difference between Group 1 and the controls (1.30 (1.10-1.55)) was observed (p<0.434). Conclusion: Carboxyhaemoglobin levels were significantly higher in exacerbations compared with the normal population. Also, in more serious exacerbations, carboxyhaemoglobin levels were significantly increased compared with healthy individuals and mild exacerbations. (author)

  4. Composition of amino acid using carbon monoxide. Amide carbonylation reaction

    Energy Technology Data Exchange (ETDEWEB)

    Izawa, Kunisuke (Ajinomoto Co., Inc., Tokyo (Japan))

    1989-02-01

    Amide carbonylation reaction is a method to compose N-acyl-{alpha}-amino acid from aldehyde, carboxylic acid amide, and carbon monoxide in a phase and with high yield. Unlike the conventional Strecker reaction, this method does not use HCN which is in question on public pollution and does not require hydrolysis. This amide carbonylation reaction was discovered by Wakamatsu and others of Ajinomoto Co.,Ltd. Present application examples of this method are the composition of N-acetyl amino acid from the aldehyde class, the composition of N-Acyl amino acid from olefin, the composition of N-acyl or acetyl amino acid from the raw material of alcohol and the halide class, the composition of N-acyl or acetyl amino acid via the isomerization of epoxide and allyl alcohol, the composition of amino dicarboxylic acid, applying deoxidation of ring acid anhydride, the composition of N-acyl amino acid from the raw material of the amine class, the stereoselective composition of -substitution ring-{alpha}-amino acid, and the composition of amino aldehyde. 24 refs., 2 figs., 2 tabs.

  5. Cumulative exposure to carbon monoxide during the day

    Energy Technology Data Exchange (ETDEWEB)

    Joumard, R. (INRETS, 69 - Bron (FR))

    The carbon monoxide, CO, has the advantage of being very easily and accurately measured under various conditions. In addition, it allows the translation of CO concentrations into their biological effects. The cumulative CO exposure should be considered according to current environment conditions during a given period of life, e.g. the day. In addition, the translation of concentrations and exposure times of CO fixed on blood haemoglobine (carboxyhaemoglobine) depends on physiological factors such as age, size, sex, or physical activity. This paper gives some examples of CO exposure translated into curves of carboxyhaemoglobine: case of 92 persons whose schedule was studied in details, of customs officers whose exposure was measured during one week, or other theoretical cases. In all the cases studied, smoking is by far the first factor of pollution by carbon monoxide. If not considering this case, the CO contents observed are preoccupying for sensitive subjects (in particular children) only in very rare cases. Furthermore, this approach allows the assessment of maximal allowable concentrations during specific exposures (work, e.g. in a tunnel) by integrating them into normal life conditions and population current exposure.

  6. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias

    2013-09-15

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  7. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    International Nuclear Information System (INIS)

    Stollenwerk, Tobias

    2013-09-01

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  8. Carbon monoxide - hydrogen combustion characteristics in severe accident containment conditions. Final report

    International Nuclear Information System (INIS)

    2000-03-01

    Carbon monoxide can be produced in severe accidents from interaction of ex-vessel molten core with concrete. Depending on the particular core-melt scenario, the type of concrete and geometric factors affecting the interaction, the quantities of carbon monoxide produced can vary widely, up to several volume percent in the containment. Carbon monoxide is a combustible gas. The carbon monoxide thus produced is in addition to the hydrogen produced by metal-water reactions and by radiolysis, and represents a possibly significant contribution to the combustible gas inventory in the containment. Assessment of possible accident loads to containment thus requires knowledge of the combustion properties of both CO and H 2 in the containment atmosphere. Extensive studies have been carried out and are still continuing in the nuclear industry to assess the threat of hydrogen in a severe reactor accident. However the contribution of carbon monoxide to the combustion threat has received less attention. Assessment of scenarios involving ex-vessel interactions require additional attention to the potential contribution of carbon monoxide to combustion loads in containment, as well as the effectiveness of mitigation measures designed for hydrogen to effectively deal with particular aspects of carbon monoxide. The topic of core-concrete interactions has been extensively studied; for more complete background on the issue and on the physical/thermal-hydraulics phenomena involved, the reader is referred to Proceedings of CSNI Specialists Meetings (Ritzman, 1987; Alsmeyer, 1992) and a State-of-Art Report (European Commission, 1995). The exact amount of carbon monoxide present in a reactor pit or in various compartments (or rooms) in a containment building is specific to the type of concrete and the accident scenario considered. Generally, concrete containing limestone and sand have a high percentage of CaCO 3 . Appendix A provides an example of results of estimates of CO and CO 2

  9. Pathology of carbon monoxide poisoning in two cats.

    Science.gov (United States)

    Sobhakumari, Arya; Poppenga, Robert H; Pesavento, J Brad; Uzal, Francisco A

    2018-03-05

    Carbon monoxide (CO), a common cause of poisoning in human beings has also been implicated in the death of animals. Though there are multiple studies on CO poisoning and relevant lethal blood COHb concentrations in humans, there are no reliable reports of diagnostic lethal carboxyhemoglobin percentage of saturation (COHb%) in cats. Additionally, due to shared housing environments, exposures to companion animals can be a surrogate for lethal exposures in human beings and provide valuable information in concurrent forensic investigations. Two adult Singapura brown ticked cats were submitted to the California Animal Health and Food Safety Laboratory (CAHFS) for necropsy and diagnostic work-up. These animals were found dead along with their two deceased owners. Similar lesions were observed in both cats. At necropsy, gross lesions consisted of multifocal, large, irregular, bright red spots on the skin of the abdomen and the inner surface of ear pinnae, bright red muscles and blood. The carcasses, and tissues fixed in formalin retained the bright red discoloration for up to two weeks. Microscopic lesions included diffuse pulmonary congestion and edema, and multifocal intense basophilia of cardiomyocytes mostly affecting whole fibers or occasionally a portion of the fiber. Based on the clinical history,gross and microscopic changes, cyanide or carbon monoxide poisoning was suspected. Blood samples analyzed for carbon monoxide showed 57 and 41% carboxyhemoglobin COHb%. Muscle samples were negative for cyanide. There are no established reference values for lethal COHb concentration in cats. The COHb % values detected in this case which fell within the lethal range reported for other species, along with the gross lesions and unique histological findings in the heart suggest a helpful criteria for diagnosis of CO intoxication associated death in cats. This case demonstrates that since pets share the same environment as human beings and often are a part of their activities

  10. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  11. Characteristic and Prediction of Carbon Monoxide Concentration using Time Series Analysis in Selected Urban Area in Malaysia

    Directory of Open Access Journals (Sweden)

    Abdul Hamid Hazrul

    2017-01-01

    Full Text Available Carbon monoxide (CO is a poisonous, colorless, odourless and tasteless gas. The main source of carbon monoxide is from motor vehicles and carbon monoxide levels in residential areas closely reflect the traffic density. Prediction of carbon monoxide is important to give an early warning to sufferer of respiratory problems and also can help the related authorities to be more prepared to prevent and take suitable action to overcome the problem. This research was carried out using secondary data from Department of Environment Malaysia from 2013 to 2014. The main objectives of this research is to understand the characteristic of CO concentration and also to find the most suitable time series model to predict the CO concentration in Bachang, Melaka and Kuala Terengganu. Based on the lowest AIC value and several error measure, the results show that ARMA (1,1 is the most appropriate model to predict CO concentration level in Bachang, Melaka while ARMA (1,2 is the most suitable model with smallest error to predict the CO concentration level for residential area in Kuala Terengganu.

  12. Carbon monoxide toxicity. January 1978-March 1989 (Citations from the Life Sciences Collection data base). Report for January 1978-March 1989

    Energy Technology Data Exchange (ETDEWEB)

    1989-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 221 citations, 19 of which are new entries to the previous edition.)

  13. Density function theory study of the adsorption and dissociation of carbon monoxide on tungsten nanoparticles.

    Science.gov (United States)

    Weng, Meng-Hsiung; Ju, Shin-Pon; Chen, Hsin-Tsung; Chen, Hui-Lung; Lu, Jian-Ming; Lin, Ken-Huang; Lin, Jenn-Sen; Hsieh, Jin-Yuan; Yang, Hsi-Wen

    2013-02-01

    The adsorption and dissociation properties of carbon monoxide (CO) molecule on tungsten W(n) (n = 10-15) nanoparticles have been investigated by density-functional theory (DFT) calculations. The lowest-energy structures for W(n) (n = 10-15) nanoparticles are found by the basin-hopping method and big-bang method with the modified tight-binding many-body potential. We calculated the corresponding adsorption energies, C-O bond lengths and dissociation barriers for adsorption of CO on nanoparticles. The electronic properties of CO on nanoparticles are studied by the analysis of density of state and charge density. The characteristic of CO on W(n) nanoparticles are also compared with that of W bulk.

  14. Spectroscopic investigations of high-power laser-induced dielectric breakdown in gas mixtures containing carbon monoxide.

    Science.gov (United States)

    Civis, Svatopluk; Babánková, Dagmar; Cihelka, Jaroslav; Sazama, Petr; Juha, Libor

    2008-08-07

    Large-scale plasma was created in gas mixtures containing carbon monoxide by high-power laser-induced dielectric breakdown (LIDB). The composition of the mixtures used corresponded to a cometary and/or meteoritic impact into the Earth's early atmosphere. A multiple-centimeter-sized fireball was created by focusing a single 85 J, 450 ps near-infrared laser pulse into the center of a 15 L gas cell. The excited reaction intermediates that formed in various stages of the LIDB plasma chemical evolution were investigated by optical emission spectroscopy (OES) with temporal resolution. Special attention was paid to any OES signs of molecular ions. However, carbon monoxide cations were registered only if their production was enhanced by Penning ionization, i.e., excess He was added to the CO. The chemical consequences of laser-produced plasma generation in a CO-N 2-H 2O mixture were investigated using high resolution Fourier-transform infrared absorption spectroscopy (FTIR) and gas chromatography (GC). Several simple inorganic and organic compounds were identified in the reaction mixture exposed to ten laser sparks. H 2 (18)O was used to avoid possible contamination. The large laser spark triggered more complex reactivity originating in carbon monoxide than expected, when taking into account the strong triple bond of carbon monoxide causing typically inefficient dissociation of this molecule in electrical discharges.

  15. Net haemoglobin increase from reinfusion of refrigerated vs. frozen red blood cells after autologous blood transfusions

    DEFF Research Database (Denmark)

    Ashenden, M; Mørkeberg, Jakob Sehested

    2011-01-01

    BACKGROUND AND OBJECTIVES  Two main blood storage procedures can be used for storing red blood cells: refrigeration and freezing. Nevertheless, the efficiency of these procedures measured as the increase in haemoglobin after reinfusion compared with baseline has never been examined. The main...... objective was to examine which storage procedure yielded the largest increase in circulating haemoglobin after reinfusion compared to baseline. MATERIALS AND METHODS  Equal volumes of blood from 15 men were withdrawn and stored either frozen or refrigerated as packed red blood cells. Serial measures...... of circulating haemoglobin by carbon monoxide rebreathing provided an opportunity to monitor recovery from anaemia, as well as the net increase in circulating haemoglobin after transfusion. RESULTS  The post-thaw yield of haemoglobin in the bags was 72% after refrigerated storage compared with only 52% after...

  16. Carbon Monoxide Poisoning: Death on Mount McKinley,

    Science.gov (United States)

    1987-05-08

    Additionally, studies by Astrup(5) and Thomas(6) have reported decreased erythrocytic 2, 3- diphosphoglycerate (2, 3-DPG) concentrations with acute...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia .(9...Astrup P: Intraerythrocytic 2,3- diphosphoglycerate and carbon monoxide exposure. Ann NY Acad Sci 1970;174:252-254. 6. Thomas MF, Penny DG: Hematologic

  17. Natural clinoptilolite exchanged with iron: characterization and catalytic activity in nitrogen monoxide reduction

    Directory of Open Access Journals (Sweden)

    Daria Tito-Ferro

    2016-12-01

    Full Text Available The aim of this work was to characterize the natural clinoptilolite from Tasajeras deposit, Cuba, modified by hydrothermal ion-exchange with solutions of iron (II sulfate and iron (III nitrate in acid medium. Besides this, its catalytic activity to reduce nitrogen monoxide with carbon monoxide/propene in the presence of oxygen was evaluated. The characterization was performed by Mössbauer and UV-Vis diffuse reflectance spectroscopies and adsorption measurements. The obtained results lead to conclude that in exchanged samples, incorporated divalent and trivalent irons are found in octahedral coordination. Both irons should be mainly in cationic extra-framework positions inside clinoptilolite channels as charge compensating cations, and also as iron oxy-hydroxides resulting from limited hydrolysis of these cations. The iron (III exchanged samples has a larger amount of iron oxy-hydroxides agglomerates. The iron (II exchanged samples have additionally iron (II sulfate adsorbed. The catalytic activity in the nitrogen monoxide reduction is higher in the exchanged zeolites than starting. Among all samples, those exchanged of iron (II has the higher catalytic activity. This lead to outline that, main catalytically active centers are associated with divalent iron.

  18. Carbon Monoxide Poisoning in a Child: A Case Report | Asani ...

    African Journals Online (AJOL)

    The exact incidence of carbon monoxide (CO) poisoning in Nigeria is unknown. Globally, CO poisoning is frequently unrecognized and under-reported since the clinical presentation is relatively non-specific. The circumstances usually involve an unsuspected increase of CO in an enclosed environment. We present the ...

  19. The effects of carbon monoxide on respiratory chemoreflexes in humans

    International Nuclear Information System (INIS)

    Vesely, A.E.; Somogyi, R.B.; Sasano, Hiroshi; Sasano, Nobuko; Fisher, J.A.; Duffin, James

    2004-01-01

    As protection against low-oxygen and high-carbon-dioxide environments, the respiratory chemoreceptors reflexly increase breathing. Since CO is also frequently present in such environments, it is important to know whether CO affects the respiratory chemoreflexes responsiveness. Although the peripheral chemoreceptors fail to detect hypoxia produced by CO poisoning, whether CO affects the respiratory chemoreflex responsiveness to carbon dioxide is unknown. The responsiveness of 10 healthy male volunteers were assessed before and after inhalation of ∼1200 ppm CO in air using two iso-oxic rebreathing tests; hypoxic, to emphasize the peripheral chemoreflex, and hyperoxic, to emphasize the central chemoreflex. Although mean (SEM) COHb values of 10.2 (0.2)% were achieved, no statistically significant effects of CO were observed. The average differences between pre- and post-CO values for ventilation response threshold and sensitivity were -0.5 (0.9) mmHg and 0.8 (0.3) L/min/mmHg, respectively, for hyperoxia, and 0.7 (1.1) mmHg and 1.2 (0.8) L/min/mmHg, respectively, for hypoxia. The 95% confidence intervals for the effect of CO were small. We conclude that environments with low levels of CO do not have a clinically significant effect acutely on either the central or the peripheral chemoreflex responsiveness to carbon dioxide

  20. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  1. Hydrogen Oxidation on Gas Diffusion Electrodes for Phosphoric Acid Fuel Cells in the Presence of Carbon Monoxide and Oxygen

    DEFF Research Database (Denmark)

    Gang, Xiao; Li, Qingfeng; Hjuler, Hans Aage

    1995-01-01

    Hydrogen oxidation has been studied on a carbon-supported platinum gas diffusion electrode in a phosphoric acidelectrolyte in the presence of carbon monoxide and oxygen in the feed gas. The poisoning effect of carbon monoxide presentin the feed gas was measured in the temperature range from 80...... to 150°C. It was found that throughout the temperaturerange, the potential loss due to the CO poisoning can be reduced to a great extent by the injection of small amounts ofgaseous oxygen into the hydrogen gas containing carbon monoxide. By adding 5 volume percent (v/o) oxygen, an almost...

  2. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    International Nuclear Information System (INIS)

    Tong, Liping; Yu, K.N.; Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi; Han, Wei

    2014-01-01

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy

  3. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Liping [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Yu, K.N. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong (Hong Kong); Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Han, Wei, E-mail: hanw@hfcas.cn [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China)

    2014-01-15

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy.

  4. Acute Compartment Syndrome Which Causes Rhabdomyolysis by Carbon Monoxide Poisoning and Sciatic Nerve Injury Associated with It: A Case Report.

    Science.gov (United States)

    Ji, Jung-Woo

    2017-09-01

    Rhabdomyolysis is most frequently caused by soft tissue injury with trauma to the extremities. Non-traumatic rhabdomyolysis may be caused by alcohol or drug abuse, infection, collagen disease, or intensive exercise, but incidence is low. In particular, rhabdomyolysis resulting from carbon monoxide poisoning is especially rare. If caught before death, carbon monoxide poisoning has been shown to cause severe muscle necrosis and severe muscle damage leading to acute renal failure. In cases of carbon-monoxide-induced rhabdomyolsis leading to acute compartment syndrome in the buttocks and sciatic nerve injury are rare. We have experience treating patients with acute compartment syndrome due to rhabdomyolysis following carbon monoxide poisoning. We report the characteristic features of muscle necrosis observed during a decompression operation and magnetic resonance imaging findings with a one-year follow-up in addition to a review of the literature.

  5. Measurements on high temperature fuel cells with carbon monoxide-containing fuel gases; Messungen an Hochtemperatur-Brennstoffzellen mit kohlenmonoxidhaltigen Brenngasen

    Energy Technology Data Exchange (ETDEWEB)

    Apfel, Holger

    2012-10-10

    In the present work the different power density of anode-supported high-temperature solid oxide fuel cells (ASC-SOFCs) were examined for carbon monoxide-containing fuels. In addition to wet hydrogen / carbon monoxide mixtures the cells were run with synthetic gas mixtures resembling the products of an autothermal reformer, and actual reformate generated by a 2 kW autothermal reformer. It was found that the power-voltage characteristics of an ASC depends primarily on the open circuit voltages of different gas mixtures, but is nearly independent of the hydrogen concentration of the fuel, although the reaction rates of other potential fuels within the gas mixture, namely carbon monoxide and methane, are much lower that the hydrogen reaction rate. The probable reason is that the main fuel for the electrochemical oxidation within the cell is hydrogen, while the nickel in the base layer of the anode acts as a reformer which replenishes the hydrogen by water reduction via carbon monoxide and methane oxidation.

  6. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    OpenAIRE

    Martijn eDiender; Alfons J.M. Stams; Alfons J.M. Stams; Diana Z. Sousa

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, ...

  7. Carbon monoxide toxicity. April 1978-November 1989 (A Bibliography from the Life Sciences Collection data base). Report for April 1978-November 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 237 citations, 16 of which are new entries to the previous edition.)

  8. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  9. 40 CFR Table 5 to Subpart Jjj of... - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units 5 Table 5 to Subpart JJJ of Part 62 Protection of... of Part 62—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units...

  10. Systemic Administration of Carbon Monoxide-Releasing Molecule-3 Protects the Skeletal Muscle in Porcine Model of Compartment Syndrome.

    Science.gov (United States)

    Bihari, Aurelia; Cepinskas, Gediminas; Sanders, David; Lawendy, Abdel-Rahman

    2018-05-01

    Acute limb compartment syndrome, a complication of musculoskeletal trauma, results in muscle necrosis and cell death. Carbon monoxide, liberated from the carbon monoxide-releasing molecule-3, has been shown protective in a rat model of compartment syndrome. The purpose of this study was to test the effect of carbon monoxide-releasing molecule-3 in a preclinical large animal model of compartment syndrome, with the ultimate goal of developing a pharmacologic adjunct treatment for compartment syndrome. Animal research study. Basic research laboratory in a hospital setting. Male Yorkshire-Landrace pigs (50-60 kg). Pigs underwent 6 hours of intracompartmental pressure elevation by infusing fluid into the anterior compartment of the right hind limb. Carbon monoxide-releasing molecule-3 was administered systemically (2 mg/kg, IV) at fasciotomy, followed by 3-hour reperfusion. Muscle perfusion, inflammation, injury, and apoptosis were assessed in the skeletal muscle. Systemic leukocyte activation was assessed during compartment syndrome and reperfusion. Elevation of hind limb intracompartmental pressure resulted in significant microvascular perfusion deficits (44% ± 1% continuously perfused capillaries in compartment syndrome vs 76% ± 4% in sham; p molecule-3 at fasciotomy increased the number of continuously perfused capillaries (68% ± 3%; p molecule-3 at fasciotomy offered protection against compartment syndrome-induced microvascular perfusion deficit, tissue injury, and systemic leukocyte activation. The data suggest the potential therapeutic application of carbon monoxide-releasing molecule-3 to patients at risk of developing compartment syndrome.

  11. The electric dipole moment of cobalt monoxide, CoO.

    Science.gov (United States)

    Zhuang, Xiujuan; Steimle, Timothy C

    2014-03-28

    A number of low-rotational lines of the E(4)Δ7/2 ← X(4)Δ7/2 (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h7/2, and the electron quadrupole parameter, eQq0, for the E(4)Δ7/2(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ(→)(el), for the X(4)Δ7/2 (υ = 0) and E(4)Δ7/2 (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F' = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F' = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  12. Silicon Monoxide at 1 atm and Elevated Pressures: Crystalline or Amorphous?

    KAUST Repository

    AlKaabi, Khalid

    2014-03-05

    The absence of a crystalline SiO phase under ordinary conditions is an anomaly in the sequence of group 14 monoxides. We explore theoretically ordered ground-state and amorphous structures for SiO at P = 1 atm, and crystalline phases also at pressures up to 200 GPa. Several competitive ground-state P = 1 atm structures are found, perforce with Si-Si bonds, and possessing Si-O-Si bridges similar to those in silica (SiO2) polymorphs. The most stable of these static structures is enthalpically just a little more stable than a calculated random bond model of amorphous SiO. In that model we find no segregation into regions of amorphous Si and amorphous SiO2. The P = 1 atm structures are all semiconducting. As the pressure is increased, intriguing new crystalline structures evolve, incorporating Si triangular nets or strips and stishovite-like regions. A heat of formation of crystalline SiO is computed; it is found to be the most negative of all the group 14 monoxides. Yet, given the stability of SiO2, the disproportionation 2SiO (s) → Si(s)+SiO2(s) is exothermic, falling right into the series of group 14 monoxides, and ranging from a highly negative ΔH of disproportionation for CO to highly positive for PbO. There is no major change in the heat of disproportionation with pressure, i.e., no range of stability of SiO with respect to SiO2. The high-pressure SiO phases are metallic. © 2014 American Chemical Society.

  13. Synthesis of ZnMn2O4 Nanoparticles by a Microwave-Assisted Colloidal Method and their Evaluation as a Gas Sensor of Propane and Carbon Monoxide

    Directory of Open Access Journals (Sweden)

    Juan Pablo Morán-Lázaro

    2018-02-01

    Full Text Available Spinel-type ZnMn2O4 nanoparticles were synthesized via a simple and inexpensive microwave-assisted colloidal route. Structural studies by X-ray diffraction showed that a spinel crystal phase of ZnMn2O4 was obtained at a calcination temperature of 500 °C, which was confirmed by Raman and UV-vis characterizations. Spinel-type ZnMn2O4 nanoparticles with a size of 41 nm were identified by transmission electron microscopy. Pellet-type sensors were fabricated using ZnMn2O4 nanoparticles as sensing material. Sensing measurements were performed by exposing the sensor to different concentrations of propane or carbon monoxide at temperatures in the range from 100 to 300 °C. Measurements performed at an operating temperature of 300 °C revealed a good response to 500 ppm of propane and 300 ppm of carbon monoxide. Hence, ZnMn2O4 nanoparticles possess a promising potential in the gas sensors field.

  14. 40 CFR Table 2 to Subpart Aaaa of... - Carbon Monoxide Emission Limits for New Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for New... Pt. 60, Subpt. AAAA, Table 2 Table 2 to Subpart AAAA of Part 60—Carbon Monoxide Emission Limits for.... Compliance is determined by continuous emission monitoring systems. b Block averages, arithmetic mean. See...

  15. Iron monoxide photodissociation

    Science.gov (United States)

    Chestakov, D. A.; Parker, D. H.; Baklanov, A. V.

    2005-02-01

    The photodissociation of Fe56O was studied by means of the velocity map imaging technique. A molecular beam of iron atoms and iron monoxide molecules was created using an electrical discharge with an iron electrode in a supersonic expansion of molecular oxygen. The ground state iron atom Fe(D45) and FeO concentrations in the molecular beam have been estimated. The dissociation energy of the FeO XΔ5 ground electronic state was found to be D00(FeO )=4.18±0.01eV. The effective absorption cross section of FeO at 252.39nm (vac), leading to the Fe(D45)+O(P3) dissociation channel, is ˜1.2×10-18cm2. A (1+1) resonantly enhanced multiphoton ionization spectrum of Fe56O in the region 39550-39580 cm-1 with rotational structure has been observed, but not assigned. Angular distributions of Fe(D45) and Fe(D35) products for the channel FeO →Fe(D4,35)+O(P3) have been measured at several points in the 210-260nm laser light wavelength region. The anisotropy parameter varies strongly with wavelength for both channels.

  16. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  17. Respiratory diseases in preschool children in the city of Niš exposed to suspended particulates and carbon monoxide from ambient air

    Directory of Open Access Journals (Sweden)

    Đorđević Amelija

    2016-01-01

    Full Text Available Background/Aim. Analysis of air quality in Serbia indicates that the city of Niš belongs to a group of cities characterized by the third category of air quality (excessive air pollution. The aim of the study was to analyze the degree of causality between ambient air quality affected by particulate matter of 10 μm (PM10 and carbon monoxide (CO and the incidence of respiratory diseases in preschool children in the city of Niš. Methods. We quantified the influence of higher PM10 concentrations and carbon monoxide comprising motor vehicle exhausts in the city of Niš on the occurrence of unwanted health effects in preschool children by means of the hazard quotient (HQ, individual health risk (Ri, and the probability of cancer (ICR. The methodology used was according to the US Environmental Protection Agency (EPA, and it included basic scientific statistical methods, compilation methods, and the relevant mathematical methods for assessing air pollution health risk, based on the use of attribute equations. Results. Measurement of ambient air pollutant concentrations in the analyzed territory for the entire monitoring duration revealed that PM10 concentrations were significantly above the allowed limits during 80% of the days. The maximum measured PM10 concentration was 191.6 μg/m3, and carbon monoxide 5.415 mg/m3. The incidence of respiratory diseases in the experimental group, with a prominent impact of polluted air was 57.17%, whereas the incidence in the control group was considerably lower, 41.10 %. There were also significant differences in the distribution of certain respiratory diseases. Conclusion. In order to perform good causal analysis of air quality and health risk, it is very important to establish and develop a system for long-term monitoring, control, assessment, and prediction of air pollution. We identified the suspended PM10 and CO as ambient air pollutants causing negative health effects in the exposed preschool children

  18. Evaluation of carbon monoxide in blood samples from the second health and nutrition survey. Progress report No. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radford, E.P.

    1976-01-01

    This is a study of carbon monoxide (CO) in the blood of human subjects participating in the Second National Health and Nutrition Survey (HANES II), a detailed study of health indicators in sample populations of many communities throughout the U.S. The purpose of this aspect of the survey is to evaluate the levels of blood carboxyhemoglobin in normal individuals of all ages in typical U.S. communities, from whom accurate histories and clinical studies are available. This report gives results of the first of three years of analyses. A careful calibration of the analytical method has been completed, and more than 3000 blood samples have been analyzed. Although smoking histories are not yet available to permit evaluation of carboxyhemoglobin in non-smokers, in children under 12 years of age, blood COHb has been found to be consistently low, with less than 3% greater than 1.5% COHb. These preliminary results suggest that urban exposure to carbon monoxide among the general population is not now significant in the U.S., at least during the period of these early examinations.

  19. Fetal brain damage following maternal carbon monoxide intoxication: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Ginsberg, M D; Myers, R E

    1974-01-01

    Techniques of fetal monitoring, including fetal blood sampling in utero, were employed to study the physiological effects of acute maternal carbon monoxide intoxication on nine term-pregnant female rhesus monkeys exposed to 0.1 to 0.3% inspired carbon monoxide over 1 to 3 hr. The mothers tolerated carboxyhemoglobin levels exceeding 60% without clinical sequelae, whereas the fetuses promptly developed profound hypoxia upon exposure of the mothers to CO. The fetal COHb levels rose only gradually over 1 to 3 hr, and thus contributed only slightly to the development of early fetal hypoxia. The fetal hypoxia was associated with bradycardia, hypotension, and metabolic and respiratory acidosis. Severity of intrauterine hypoxia was closely correlated with the appearance of brain damage. Brain swelling associated with hemorrhagic necrosis of the cerebral hemispheres (severe brain damage) appeared only in fetuses whose arterial oxygen content was reduced below 1.0 ml/100 ml for at least 45 min during the maternal CO intoxication.

  20. Iodine monoxide in the north subtropical free troposphere

    OpenAIRE

    O. Puentedura; M. Gil; A. Saiz-Lopez; T. Hay; M. Navarro-Comas; A. Gómez-Pelaez; E. Cuevas; J. Iglesias; L. Gomez

    2012-01-01

    Iodine monoxide (IO) differential slant column densities (DSCD) have been retrieved from a new multi-axis differential optical absorption spectroscopy (MAX-DOAS) instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and hence is representative of the free troposphere. We r...

  1. Hyperventilation with Maintenance of Isocapnia. An "Old New" Method in Carbon Monoxide Intoxication.

    Directory of Open Access Journals (Sweden)

    Jacek Sein Anand

    Full Text Available Exposure to carbon monoxide (CO is among the most common causes of acute and chronic poisonings worldwide. The crucial point of treatment of such acute poisonings is to eliminate CO from the body as fast as possible. There are currently two approaches to the management of the CO intoxication: hyperbaric oxygen therapy (HOT and normobaric oxygen therapy (NOT. HOT is highly effective and capable of achieving the CO elimination half-time (T½ as low as 15 minutes. Unfortunately this method is expensive and not always readily available. The elimination of CO with the use of NOT (T½~70 min is slower, but treatment can be started even on the site of the exposure and continued while the patient is transported to a hospital. The aim of the study was to evaluate the effectiveness of a method using therapeutic hyperventilation with maintenance of isocapnia (IH in the elimination of CO in volunteers exposed to CO and to compare selected gasometric and respiratory parameters during IH with the values obtained during hyperventilation with pure oxygen ("non-isocapnic hyperventilation"-NIH.The study involved 13 healthy, chronically-smoking volunteers. Each of them participated in two independent hyperventilation tests: IH and NIH. The levels of carboxyhemoglobin (COHb and selected gasometric, cardiac and respiratory parameters were measured at 0, 10 and 20 minutes during both tests. Among 13 volunteers (8 women and 5 men the initial COHb level was 5.0±1.5% (mean±SD before the IH tests and 5.1±1.9% before the NIH tests (p>0.05. After 20 minutes of the procedures the mean COHb level was 2.9±0.9% for IH and 3.6±1.2% for NIH (p<0.01. The T½ of COHb was 29.6±12.2 min and 47.3±19.2 min respectively (p<0.01. After 10 minutes of NIH respiratory alkalosis was noted in 11 participants (84.6%. Such problem was not seen during the IH procedures. No serious adverse effects were recorded during either IH or NIH. Mild symptoms such as: dyspnea, headache and

  2. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  3. The deployment of carbon monoxide wireless sensor network (CO-WSN) for ambient air monitoring.

    Science.gov (United States)

    Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C; Khang, Soon-Jai

    2014-06-16

    Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011-2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1-1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring.

  4. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    Science.gov (United States)

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  5. The electric dipole moment of cobalt monoxide, CoO

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Xiujuan, E-mail: zhuangxj@hnu.edu.cn [College of Physics and Microelectronics Science, Key Laboratory for Micro-Nano Physics and Technology of Hunan Province, Hunan University, Changsha 410082 (China); Steimle, Timothy C. [Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287-1604 (United States)

    2014-03-28

    A number of low-rotational lines of the E{sup 4}Δ{sub 7/2} ← X{sup 4}Δ{sub 7/2} (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h{sub 7/2}, and the electron quadrupole parameter, eQq{sub 0}, for the E{sup 4}Δ{sub 7/2}(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ{sup -vector}{sub el}, for the X{sup 4}Δ{sub 7/2} (υ = 0) and E{sup 4}Δ{sub 7/2} (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F′ = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F′ = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  6. Personal child and mother carbon monoxide exposures and kitchen levels: methods and results from a randomized trial of woodfired chimney cookstoves in Guatemala (RESPIRE).

    Science.gov (United States)

    Smith, Kirk R; McCracken, John P; Thompson, Lisa; Edwards, Rufus; Shields, Kyra N; Canuz, Eduardo; Bruce, Nigel

    2010-07-01

    During the first randomized intervention trial (RESPIRE: Randomized Exposure Study of Pollution Indoors and Respiratory Effects) in air pollution epidemiology, we pioneered application of passive carbon monoxide (CO) diffusion tubes to measure long-term personal exposures to woodsmoke. Here we report on the protocols and validations of the method, trends in personal exposure for mothers and their young children, and the efficacy of the introduced improved chimney stove in reducing personal exposures and kitchen concentrations. Passive diffusion tubes originally developed for industrial hygiene applications were deployed on a quarterly basis to measure 48-hour integrated personal carbon monoxide exposures among 515 children 0-18 months of age and 532 mothers aged 15-55 years and area samples in a subsample of 77 kitchens, in households randomized into control and intervention groups. Instrument comparisons among types of passive diffusion tubes and against a continuous electrochemical CO monitor indicated that tubes responded nonlinearly to CO, and regression calibration was used to reduce this bias. Before stove introduction, the baseline arithmetic (geometric) mean 48-h child (n=270), mother (n=529) and kitchen (n=65) levels were, respectively, 3.4 (2.8), 3.4 (2.8) and 10.2 (8.4) p.p.m. The between-group analysis of the 3355 post-baseline measurements found CO levels to be significantly lower among the intervention group during the trial period: kitchen levels: -90%; mothers: -61%; and children: -52% in geometric means. No significant deterioration in stove effect was observed over the 18 months of surveillance. The reliability of these findings is strengthened by the large sample size made feasible by these unobtrusive and inexpensive tubes, measurement error reduction through instrument calibration, and a randomized, longitudinal study design. These results from the first randomized trial of improved household energy technology in a developing country and

  7. Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production

    Directory of Open Access Journals (Sweden)

    Perez Roberto SGM

    2005-06-01

    Full Text Available Abstract Background Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all. The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime. Methods A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams was used in this system. A low flow anesthesia (500 ml/min was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container. Results Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively. It was lower with isoflurane (2512 ppm. We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions. Conclusion All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.

  8. [Cerebellar Infarction After Carbon Monoxide Poisoning and Hyperbaric Oxygen Therapy].

    Science.gov (United States)

    Wick, Matthias; Schneiker, André; Bele, Sylvia; Pawlik, Michael; Meyringer, Helmut; Graf, Bernhard; Wendl, Christina; Kieninger, Martin

    2017-06-01

    We report on a patient who developed a space-occupying cerebellar infarction with occlusive hydrocephalus after a poisoning with carbon monoxide with the intention to commit suicide. A neurosurgical and intensive care therapy were needed. The patient's survival without severe neurological deficits could be secured due to the early detection of the intracerebral lesions. Georg Thieme Verlag KG Stuttgart · New York.

  9. 40 CFR Table 5 to Subpart Bbbb of... - Model Rule-Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Carbon Monoxide Emission... BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste... PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...

  10. Cerebral vasomotor reactivity: steady-state versus transient changes in carbon dioxide tension.

    Science.gov (United States)

    Brothers, R Matthew; Lucas, Rebekah A I; Zhu, Yong-Sheng; Crandall, Craig G; Zhang, Rong

    2014-11-01

    Cerebral vasomotor reactivity (CVMR) to changes in arterial carbon dioxide tension (P aCO 2) is assessed during steady-state or transient changes in P aCO 2. This study tested the following two hypotheses: (i) that CVMR during steady-state changes differs from that during transient changes in P aCO 2; and (ii) that CVMR during rebreathing-induced hypercapnia would be blunted when preceded by a period of hyperventilation. For each hypothesis, end-tidal carbon dioxide tension (P ET , CO 2) middle cerebral artery blood velocity (CBFV), cerebrovascular conductance index (CVCI; CBFV/mean arterial pressure) and CVMR (slope of the linear regression between changes in CBFV and CVCI versus P ET , CO 2) were assessed in eight individuals. To address the first hypothesis, measurements were made during the following two conditions (randomized): (i) steady-state increases in P ET , CO 2 of 5 and 10 Torr above baseline; and (ii) rebreathing-induced transient breath-by-breath increases in P ET , CO 2. The linear regression for CBFV versus P ET , CO 2 (P = 0.65) and CVCI versus P ET , CO 2 (P = 0.44) was similar between methods; however, individual variability in CBFV or CVCI responses existed among subjects. To address the second hypothesis, the same measurements were made during the following two conditions (randomized): (i) immediately following a brief period of hypocapnia induced by hyperventilation for 1 min followed by rebreathing; and (ii) during rebreathing only. The slope of the linear regression for CBFV versus P ET , CO 2 (P < 0.01) and CVCI versus P ET , CO 2 (P < 0.01) was reduced during hyperventilation plus rebreathing relative to rebreathing only. These results indicate that cerebral vasomotor reactivity to changes in P aCO 2 is similar regardless of the employed methodology to induce changes in P aCO 2 and that hyperventilation-induced hypocapnia attenuates the cerebral vasodilatory responses during a subsequent period of rebreathing

  11. Carbon monoxide is not responsible for the cigarette smokeinduced changes in the pulmonary metabolism of arachidonic acid and prostaglandin E2

    International Nuclear Information System (INIS)

    Maennistoe, J.; Puustinen, T.; Uotila, P.

    1985-01-01

    Cigarette smoke is known to interfere with the pulmonary metabolism of arachidomic acid and prostaglandin E 2 (PGE 2 ). We investigated the possible role of carbon monoxide in these cigarette smoke-infuced alterations. 4 C-Arachidonic acid (50 nmol) was indused into the pulmonary circulation of isolated perfused hamster lungs and the radioactive metabolites in the perfusion effluent, as well as the distribution of incorporated radioactive arachidonic acid within the lung lipids, were analysed. Carbon monoxide, added into the ventilatory air, had no effect on the oxidative metabolism of arachidonic acid or on the distribution of radioactive arachidonic acid within the lung. In addition, carbon monoxide had no effect on the metabolism of PGE 2 following infusion of 100 nmol of 14 C-PGE 2 into the rat pulmonary circulation. The present study suggests that carbon monoxide is not responsible for the cigarette smoke-induced changes in the pulmonary metabolism of arachidonic acid and PGE 2 . (author)

  12. Exhaled carbon monoxide: a non-invasive biomarker of short-term exposure to outdoor air pollution

    Directory of Open Access Journals (Sweden)

    Herve Lawin

    2017-04-01

    Full Text Available Abstract Background In urban settings of Africa with rapidly increasing population, traffic-related air pollution is a major contributor to outdoor air pollution (OAP. Although OAP has been identified as a leading cause of global morbidity and mortality, there is however, lack of a simple biomarker to assess levels of exposure to OAP in resource-poor settings. This study evaluated the role of exhaled carbon monoxide (exhCO as a potential biomarker of exposure to ambient carbon monoxide (ambCO from OAP. Methods This was a descriptive study conducted among male commercial motorcycle riders in Cotonou – the economic capital of Benin. The participants’ AmbCO was measured using a portable carbon monoxide (CO data logger for 8 h during the period of their shift. ExhCO was measured just before and immediately after their shift (8-h Participants were asked not to cook or to smoke during the day of the measurements. Linear regression analysis was used to assess the association between ambCO and exhCO for the last 2, 4 and 6 h of their shift. Results Of 170 participants who completed the study, their mean ± SD age was 42.2 ± 8.4 years, and their mean ± SD daily income was 7.3 ± 2.7$. Also, 95% of the participants’ used solid fuels for cooking and only 2% had ever smoked. Average exhCO increased by 5.1 ppm at the end of the shift (p = 0.004. Post-shift exhCO was significantly associated to ambCO, this association was strongest for the last 2 h of OAP exposure before exhCO measurement (β = 0.34, p < 0.001. Conclusion ExhCO level was associated with recent exposure to ambCO from OAP with measurable increase after 8 h of exposure. These findings suggest that ExhCO may be a potential biomarker of short-term exposure to OAP.

  13. Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.

    Science.gov (United States)

    Towers, Craig V; Corcoran, Vincent A

    2009-03-01

    The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.

  14. Effects of acetylene and carbon monoxide on long-term hydrogen production by Mastigocladus laminosus, a thermophilic blue-green alga

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Yokoyama, H; Takahara, K; Miyamoto, K

    1982-01-01

    Long-term H/sub 2/ production by a thermophilic and heterocystous blue-green alga (cyanobacterium) Mastigocladus laminosus was studied under the conditions when acetylene and carbon monoxide were supplemented to the gas phase of the culture vessel. The addition of both gases enhanced H/sub 2/ evolution by nitrogen-starved cells. The concentrations of acetylene and carbon monoxide in the gas phase of argon/CO/sub 2/ (97.5/2.5) were 10% and 0.2 to 1%, respectively, for the maximum H/sub 2/ production. Renewals of the gas phase, in addition to the addition of acetylene and carbon monoxide, were necessary for durable H/sub 2/ production. Since the concentrations of both H/sub 2/ and O/sub 2/ accumulated in the gas phase were minimized after the renewals, the H/sub 2/ uptake activity, which was not completely inhibited by acetylene and carbon monoxide, was reduced and thereby H/sub 2/ evolution was restored. Under such conditions, H/sub 2/ production for up to 20 days was observed under argon and N/sub 2/ atmospheres with average rats of 3.9 and 3.3..mu..l/mg dry wt/h, respectively. H/sub 2/ evolution for 15 days was observed even under an air atmosphere containing acetylene and carbon monoxide. It was thus shown that prolonged production of H/sub 2/ was possible by the use of a blue-green alga which exhibits a high activity of H/sub 2/ uptake under nitrogen-starved conditions.

  15. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases

    Directory of Open Access Journals (Sweden)

    A. Mishra

    2011-05-01

    Full Text Available In this review, recent works on the preferential oxidation of carbon monoxide in hydrogen rich gases for fuel cell applications are summarized. H2 is used as a fuel for polymer-electrolyte membrane fuel cell (PEMFC. It is produced by reforming of natural gas or liquid fuels followed by water gas shift reaction. The produced gas consists of H2, CO, and CO2. In which CO content is around 1%, which is highly poisonous for the Pt anode of the PEMFC so that further removal of CO is needed. Catalytic preferential oxidation of CO (CO-PROX is one of the most suitable methods of purification of H2 because of high CO conversion rate at low temperature range, which is preferable for PEMFC operating conditions. Catalysts used for COPROX are mainly noble metal based; gold based and base metal oxide catalysts among them Copper-Ceria based catalysts are the most appropriate due to its low cost, easy availability and result obtained by these catalysts are comparable with the conventional noble metal catalysts. Copyright © 2011 BCREC UNDIP. All rights reserved(Received: 22nd October 2010, Revised: 12nd January 2011, Accepted: 19th January 2011[How to Cite: A. Mishra, R. Prasad. (2011. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases. Bulletin of Chemical Reaction Engineering & Catalysis, 6 (1: 1-14. doi:10.9767/bcrec.6.1.191.1-14][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.1.191.1-14 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/191] | View in 

  16. Geostatistical modelling of carbon monoxide levels in Khartoum State (Sudan) - GIS pilot based study

    Energy Technology Data Exchange (ETDEWEB)

    Alhuseen, A [Comenius University in Bratislava, Faculty of Natural Sciences, Dept. of Landscape Ecology, 84215 Bratislava (Slovakia); Madani, M [Ministry of Environment and Physical Development, 1111 Khartoum (Sudan)

    2012-04-25

    The objective of this study is to develop a digital GIS model; that can evaluate, predict and visualize carbon monoxide (CO) levels in Khartoum state. To achieve this aim, sample data had been collected, processed and managed to generate a dynamic GIS model of carbon monoxide levels in the study area. Parametric data collected from the field and analysis carried throughout this study show that (CO) emissions were lower than the allowable ambient air quality standards released by National Environment Protection Council (NEPC-USA) for 1998. However, this pilot study has found emissions of (CO) in Omdurman city were the highest. This pilot study shows that GIS and geostatistical modeling can be used as a powerful tool to produce maps of exposure. (authors)

  17. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad; Farooq, Aamir

    2018-01-01

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm

  18. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    Science.gov (United States)

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  19. Catalytic hydrogenation of carbon monoxide

    International Nuclear Information System (INIS)

    Wayland, B.B.

    1993-12-01

    Focus of this project is on developing new approaches for hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. The strategies to accomplish CO reduction are based on favorable thermodynamics manifested by rhodium macrocycles for producing a series of intermediates implicated in the catalytic hydrogenation of CO. Metalloformyl complexes from reactions of H 2 and CO, and CO reductive coupling to form metallo α-diketone species provide alternate routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics are promising candidates for future development

  20. Deteriorations of pulmonary function, elevated carbon monoxide levels and increased oxidative stress amongst water-pipe smokers

    Directory of Open Access Journals (Sweden)

    Funda Karaduman Yalcin

    2017-10-01

    Full Text Available Objectives: A water pipe (hookah is a tobacco smoking tool which is thought to be more harmless than a cigarette, and there are no adequate studies about its hazards to health. Water-pipe smoking is threatening health of the youth in the world today. The objective of this study has been to investigate the carbon monoxide (CO levels in breath, examine the changes in pulmonary function tests (PFT and to assess the change of the oxidative stress parameters in blood after smoking a water pipe. Material and Methods: This study is a cross-sectional analytical study that has included 50 volunteers who smoke a water pipe and the control group of 50 volunteers who smoke neither a cigarette nor a water pipe. Carbon monoxide levels were measured in the breath and pulmonary function tests (PFTs were performed before and after smoking a water pipe. Blood samples were taken from either the volunteer control group or water-pipe smokers group after smoking a water pipe for the purpose of evaluation of the parameters of oxidative stress. Results: Carbon monoxide values were measured to be 8.08±7.4 ppm and 28.08±16.5 ppm before and after smoking a water pipe, respectively. This increment was found statistically significant. There were also significant reductions in PFTs after smoking a water pipe. Total oxidative status (TOS, total antioxidant status (TAS and oxidative stress index (OSI were found prominently higher after smoking a water pipe for the group of water-pipe smokers than for the control group. Conclusions: This study has shown that water-pipe smoking leads to deterioration in pulmonary function and increases oxidative stress. To the best of our knowledge this study is the only one that has shown the effect of water-pipe smoking on oxidative stress. More studies must be planned to show the side effects of water-pipe habit and protective policies should be planned especially for young people in Europe. Int J Occup Med Environ Health 2017;30(5:731

  1. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    Science.gov (United States)

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  2. Calculated Specific Volumes and Magnetic Moments of the 3d Transition Metal Monoxides

    DEFF Research Database (Denmark)

    Skriver, Hans Lomholt; Andersen, O. K.; Johansson, B.

    1980-01-01

    We have performed self-consistent, spin-polarized band structure calculations as a function of the lattice spacing for the 3d metal monoxides in order to obtain the equilibrium lattice constants. The calculated binding from the 3d electrons and the occurrence of antiferromagnetism account...

  3. Multimodel simulations of carbon monoxide: comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Krol, M.C.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-ofthe- art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  4. Multimodel simulations of carbon monoxide: Comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Faluvegi, G.; Stevenson, D.S.; Krol, M.C.; Emmons, L.K.; Lamarque, J.F.; Petron, G.; Dentener, F.J.; Ellingsen, K.; Schultz, M.G.; Wild, O.; Amann, M.; Atherton, C.S.; Bergmann, D.J.; Bey, I.; Butler, T.; Cofala, J.; Collins, W.J.; Derwent, R.G.; Doherty, R.M.; Drevet, J.; Eskes, H.J.; Fiore, A.M.; Gauss, M.; Hauglustaine, D.A.; Horowitz, L.W.; Isaksen, I.S.A.; Lawrence, M.G.; Montanaro, V.; Muller, J.F.; Pitari, G.; Prather, M.J.; Pyle, J.A.; Rast, S.; Rodriguez, J.M.; Sanderson, M.G.; Savage, N.H.; Strahan, S.E.; Sudo, K.; Szopa, S.; Unger, N.; Noije, van T.P.C.; Zeng, G.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-of-the-art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  5. Kinetic laws of deep oxidations of n-butane and carbon monoxide at presence Cu-Cr-Co/Al2O3/Al-frame catalysts

    International Nuclear Information System (INIS)

    Muradova, P.A; Djafarova, S.A; Seyfullayeva, Z.M; Efendiyev, M.R; Litvishkov, Yu. N.

    2007-01-01

    Full text: The results of research laws of reaction of deep oxidation of n-butane and carbon monoxide in the presence of Cu-Cr-Co/AL 2 O 3 /Al-frame catalysts are sited, with the purpose of acknowledgement of stated before assumptions on the physic oxidation-reduction mechanism of observable transformations. It is established, that dependence of an output of carbon monoxide on a degree of transformation of n-butane in an area of its relatively values, has extreme character that is typical for formation and an expenditure of intermediate products under the consecutive circuit. In area of low transformations of hydrocarbon CO and CO 2 are formed by parallel way. The generalized physic circuit of the postulated mechanism of joint transformation of n-butane and CO on three independent reactionary routes and kinetic model of process corresponding to it is offered. With use of settlement methods of optimization the estimation of parameters of the offered kinetic model has been out

  6. A comparison of hydrogen-bonded and van der Waals isomers of phenolṡṡnitrogen and phenolṡṡcarbon monoxide: An ab initio study

    Science.gov (United States)

    Chapman, Darren M.; Müller-Dethlefs, Klaus; Peel, J. Barrie

    1999-08-01

    The hydrogen-bonded and van der Waals isomers of phenolṡṡnitrogen and phenolṡṡcarbon monoxide in their neutral electronic (S0) and cation ground state (D0) were studied using ab initio HF/6-31G*, MP2/6-31G*, and B3LYP/6-31G* methods. The hydrogen-bonded isomers have the ligand bound via the hydroxyl group of the phenol ring, while the van der Waals isomers studied have the ligand located above the aromatic ring. For both complexes, the hydrogen-bonded isomer was found to be the most stable form for both the S0 and the D0 states. For phenolṡṡcarbon monoxide, twice as many isomers as compared to phenolṡṡnitrogen were found. The hydrogen-bonded isomer with the carbon end bonded to the hydroxyl group was the most stable structure for both the S0 and the D0 states.

  7. On the Pt(+) and Rh(+) Catalytic Activity in the Nitrous Oxide Reduction by Carbon Monoxide.

    Science.gov (United States)

    Rondinelli, F; Russo, N; Toscano, M

    2008-11-11

    Nitrous oxide activation by CO in the presence of platinum and rhodium monocations was elucidated by density functional methods for ground and first excited states. Platinum and rhodium cations fulfill the thermodynamic request for the oxygen-atom transport that allows the catalytic cycle to be completed, but actually, just the first one meaningfully improves the kinetics of the process. For both catalysts, the reaction pathways show the only activation barrier in correspondence of nitrogen release and monoxide cation formation. The kinetic analysis of the potential energy profile, in agreement with ICP/SIFT MS experimental data, indicates that platinum performs more in the reduction, while the whole process is not sufficiently fast in the case of rhodium ionic catalyst.

  8. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Directory of Open Access Journals (Sweden)

    Martijn eDiender

    2015-11-01

    Full Text Available Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  9. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    Science.gov (United States)

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  10. Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians.

    Science.gov (United States)

    Stanojevic, Sanja; Graham, Brian L; Cooper, Brendan G; Thompson, Bruce R; Carter, Kim W; Francis, Richard W; Hall, Graham L

    2017-09-01

    There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide ( T  LCO ); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T  LCO Data from 19 centres in 14 countries were collected to define T  LCO reference values. Similar to the GLI spirometry project, reference values were derived using the LMS (lambda, mu, sigma) method and the GAMLSS (generalised additive models for location, scale and shape) programme in R.12 660 T  LCO measurements from asymptomatic, lifetime nonsmokers were submitted; 85% of the submitted data were from Caucasians. All data were uncorrected for haemoglobin concentration. Following adjustments for elevation above sea level, gas concentration and assumptions used for calculating the anatomic dead space volume, there was a high degree of overlap between the datasets. Reference values for Caucasians aged 5-85 years were derived for T  LCO , transfer coefficient of the lung for carbon monoxide and alveolar volume.This is the largest collection of normative T  LCO data, and the first global reference values available for T  LCO . Copyright ©ERS 2017.

  11. Selected constituents in the smokes of U. S. commercial cigaretts: tar, nicotine, carbon monoxide and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    One hundred twenty-one brands of United States commercial cigarettes were analyzed for their deliveries of tar, nicotine, carbon monoxide, and carbon dioxide under standard analytical smoking conditions. The sample included both filter and nonfilter cigarettes. Comparisons of carbon monoxide deliveries over the range of observed tar deliveries indicated a very high correlation between CO and tar for filter cigarettes, but nonfilter cigarettes tended to produce much less CO than would have been predicted from their tar deliveries. Comparison of ORNL nicotine values for specific brands with those determined by the Federal Trade Commission yield no statistically significant differences between laboratories. 4 figures, 6 tables.

  12. Quantitative Romberg's test in acute carbon monoxide poisoning treated by hyperbaric oxygen

    DEFF Research Database (Denmark)

    Bidstrup, Daniel; Jansen, Erik Christian; Hyldegaard, Ole

    2017-01-01

    LMM, sway prior to HBO₂ therapy was set as the fixed effect and change in sway after HBO₂ therapy was set as the response variable. Patient, treatment number, weight and age were set as random effects for all LMMs. RESULTS: From the LMMs we found that larger values of sway prior to HBO₂ produced......OBJECTIVE: The aim of this study was to evaluate whether monitoring of acute carbon monoxide-poisoned (COP) patients by means of quantitative Romberg's test (QR-test) during a hyperbaric oxygen (HBO₂) therapy regimen could be a useful supplement in the evaluation of neurological status. METHODS: We...... conducted a retrospective study (2000-2014) in which we evaluated data containing quantitative sway measurements of acute COP patients (n = 58) treated in an HBO₂ regimen. Each patient was tested using QR-test before and after each HBO₂ treatment. Data were analyzed using linear mixed models (LMM). In each...

  13. High Resolution Spectra of Carbon Monoxide, Propane and Ammonia for Atmospheric Remote Sensing

    Science.gov (United States)

    Beale, Christopher Andrew

    Spectroscopy is a critical tool for analyzing atmospheric data. Identification of atmospheric parameters such as temperature, pressure and the existence and concentrations of constituent gases via remote sensing techniques are only possible with spectroscopic data. These form the basis of model atmospheres which may be compared to observations to determine such parameters. To this end, this dissertation explores the spectroscopy of three molecules: ammonia, propane and carbon monoxide. Infrared spectra have been recorded for ammonia in the region 2400-9000 cm-1. These spectra were recorded at elevated temperatures (from 293-973 K) using a Fourier Transform Spectrometer (FTS). Comparison between the spectra recorded at different temperatures yielded experimental lower state energies. These spectra resulted in the measurement of roughly 30000 lines and about 3000 quantum assignments. In addition spectra of propane were recorded at elevated temperatures (296-700 K) using an FTS. Atmospheres with high temperatures require molecular data at appropriate conditions. This dissertation describes collection of such data and the potential application to atmospheres in our solar system, such as auroral regions in Jupiter, to those of planets orbiting around other stars and cool sub-stellar objects known as brown dwarfs. The spectra of propane and ammonia provide the highest resolution and most complete experimental study of these gases in their respective spectral regions at elevated temperatures. Detection of ammonia in an exoplanet or detection of propane in the atmosphere of Jupiter will most likely rely on the work presented here. The best laboratory that we have to study atmospheres is our own planet. The same techniques that are applied to these alien atmospheres originated on Earth. As such it is appropriate to discuss remote sensing of our own atmosphere. This idea is explored through analysis of spectroscopic data recorded by an FTS on the Atmospheric Chemistry

  14. A Rare Cause of Chronic Headache that May Be Misdiagnosed as Migraine: Chronic Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet Kenan KANBUROGLU

    2014-09-01

    Full Text Available SUMMARY: Differential diagnosis of primary headache disorders can be challenging for physicians. Although the association of headache with acute carbon monoxide intoxication is very well-defined, in refractory nonspecific headaches associated with chronic low dose exposure to carbon monoxide, CO intoxication is usually overlooked, mostly due to vague symptoms. Herein we present a 15-year-old female patient with chronic carbon monoxide poisoning who was undergoing two years of follow-up care for migraines. Chronic carbon monoxide intoxication may mimic the episodic nature and familial predisposition of migraine attacks. Normal carboxyhemoglobin levels do not exclude the diagnosis, and smoking is a confounding factor. In emergency rooms, patients presenting with headaches had higher levels of carboxyhemoglobin, but, as far as we know, there have been no studies investigating carboxyhemoglobin levels in migraine patients. Chronic carbon monoxide poisoning should be suspected in migraine patients, especially if the attacks occur during winter months. ÖZET: Primer baş ağrısında ayırıcı tanının yapılması bazen doktorlar açısından zor olabilmektedir. Literatürde karbon monoksit ile baş ağrısı arasındaki ilişki çok iyi ortaya konulmuş olmasına karşın, dirençli ve nonspesifik başağrısı nedenlerinden biri olan kronik düşük doz karbon monoksit maruziyeti kendine özgü bulgusu olmadığından sıklıkla atlanmaktadır. Bu yazıda, iki yıl migren tanısı ile takip ve tedavi edilen kronik karbon monoksit zehirlenmesi olan bir olgu sunuldu. Kronik karbon monoksit zehirlenmesi epizodik paterni ve aile fertlerinde benzer şikayetlerin olması nedeniyle migren ataklarını andırabilmektedir. Karboksihemoglobin konsantrasyonlarının normal saptanması tanıyı ekarte ettirmemekte, ayrıca sigara kullanımı da karıştırıcı bir faktör olabilmektedir. Acil servislerine baş ağrısı ile başvuran hastalar

  15. Gas-phase studies of AunOm+ interacting with carbon monoxide

    Science.gov (United States)

    Kimble, M. L.; Castleman, A. W.

    2004-04-01

    The results of reactions between preformed cationic gold oxide clusters and carbon monoxide have been investigated utilizing a fast-flow reactor mass spectrometer. From these studies, it was found that all AunOm+ produced in the cluster source disappeared with CO addition at the reactant gas inlet. Furthermore, with CO addition, intermediate peaks of the form AunOm(CO)x+ (n=1-2, m=0-3, x=0-2) were produced, with some of the species continuing to react at higher CO flows.

  16. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Science.gov (United States)

    Wu, Martin; Ren, Qinghu; Durkin, A Scott; Daugherty, Sean C; Brinkac, Lauren M; Dodson, Robert J; Madupu, Ramana; Sullivan, Steven A; Kolonay, James F; Haft, Daniel H; Nelson, William C; Tallon, Luke J; Jones, Kristine M; Ulrich, Luke E; Gonzalez, Juan M; Zhulin, Igor B; Robb, Frank T; Eisen, Jonathan A

    2005-11-01

    We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO) as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  17. Life in Hot Carbon Monoxide: The Complete Genome Sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  18. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    Martin Wu

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  19. An evaluation of fresh gas flow rates for spontaneously breathing cats and small dogs on the Humphrey ADE semi-closed breathing system.

    Science.gov (United States)

    Gale, Elizabeth; Ticehurst, Kim E; Zaki, Sanaa

    2015-05-01

    To evaluate the fresh gas flow (FGF) rate requirements for the Humphrey ADE semi-closed breathing system in the Mapleson A mode; to determine the FGF at which rebreathing occurs, and compare the efficiency of this system to the Bain (Mapleson D) system in spontaneously breathing cats and small dogs. Prospective clinical study. Twenty-five healthy (ASA score I or II) client-owned cats and dogs (mean ± SD age 4.7 ± 5.0 years, and body weight 5.64 ± 3.26 kg) undergoing elective surgery or minor procedures. Anaesthesia was maintained with isoflurane delivered via the Humphrey ADE system in the A mode using an oxygen FGF of 100 mL kg(-1) minute(-1). The FGF was then reduced incrementally by 5-10 mL kg(-1) minute(-1) at approximately five-minute intervals, until rebreathing (inspired CO(2) >5 mmHg (0.7 kPa)) was observed, after which flow rates were increased. In six animals, once the minimum FGF at which rebreathing occurred was found, the breathing system was changed to the Bain, and the effects of this FGF delivery examined, before FGF was increased. Rebreathing did not occur at the FGF recommended by the manufacturer for the ADE. The mean ± SD FGF that resulted in rebreathing was 60 ± 20 mL kg(-1) minute(-1). The mean minimum FGF at which rebreathing did not occur with the ADE was 87 ± 39 mL kg(-1) minute(-1). This FGF resulted in significant rebreathing (inspired CO(2) 8.8 ± 2.6 mmHg (1.2 ± 0.3 kPa)) on the Bain system. The FGF rates recommended for the Humphrey ADE are adequate to prevent rebreathing in spontaneously breathing cats and dogs cats and small dogs. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  20. Ratio of carbon monoxide to molecular hydrogen in interstellar dark clouds

    International Nuclear Information System (INIS)

    Dickman, R.L.; Rensselaer Polytechnic Institute; and The Ivan A. Getting Laboratories, The Aerospace Corporation)

    1978-01-01

    Carbon monoxide and molecular hydrogen column densities are compared at various locations within 38 interstellar dark clouds. CO column densities were obtained from radio observations of the J=1→0 transitions of the 12 C 16 O and 13 C 16 O isotopic species of the molecule. Corresponding H 2 column densities were inferred by means of visual extinctions derived from star counts, since it is argued that the standard gas-to-extinction ratio can be expected to remain valid in the clouds studied. For locations in the sources possessing line-of-sight visual extinctions in the approximate range 1.5 -2 ) = (5.0 +- 2.5) x 10 5 N 13 between molecular hydrogen and 13 CO LTE column densities. The carbon monoxide molecule can therefore be used as a quantitative ''tracer'' for the (directly unobservable) H 2 content of dark clouds. The above relationship implies that at least approx.12% of the gas-phase carbon in the clouds studied is in the form of CO, provided that the clouds are assumed to be chemically homogeneous. Langer's ion-molecule chemistry for dark clouds appears to agree well with the present work if the fractionation channel of Watson, Anicich, and Huntress is included

  1. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Science.gov (United States)

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  2. Method for producing carbon nanotubes

    Science.gov (United States)

    Phillips, Jonathan [Santa Fe, NM; Perry, William L [Jemez Springs, NM; Chen, Chun-Ku [Albuquerque, NM

    2006-02-14

    Method for producing carbon nanotubes. Carbon nanotubes were prepared using a low power, atmospheric pressure, microwave-generated plasma torch system. After generating carbon monoxide microwave plasma, a flow of carbon monoxide was directed first through a bed of metal particles/glass beads and then along the outer surface of a ceramic tube located in the plasma. As a flow of argon was introduced into the plasma through the ceramic tube, ropes of entangled carbon nanotubes, attached to the surface of the tube, were produced. Of these, longer ropes formed on the surface portion of the tube located in the center of the plasma. Transmission electron micrographs of individual nanotubes revealed that many were single-walled.

  3. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  4. Non-intentional motor vehicle-related carbon monoxide deaths-revisited

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, A.R.

    1986-01-01

    A study of non-intentional, motor vehicle-related, carbon monoxide-related deaths was performed on the case files of the Office of the Medical Examiner of Metropolitan Dade Country in Miami, FL (USA) during the years 1980-1984. A total of 15 cases were collected during that time period. These are presented in some detail. A discussion ensues that compares the similar circumstances of these cases, notably running the engine of an automobile in an enclosed space, with older reports in the literature which emphasized defective vehicle exhaust systems as the leading etiology for these deaths.

  5. Human umbilical cord blood mononuclear cell transplantation for delayed encephalopathy after carbon monoxide intoxication

    Directory of Open Access Journals (Sweden)

    Gong D

    2013-08-01

    Full Text Available Dianrong Gong,1 Haiyan Yu,1 Weihua Wang,2 Haixin Yang,1 Fabin Han1,21Department of Neurology, 2Centre for Stem Cells and Regenerative Medicine, Liaocheng People's Hospital, The Affiliated Liaocheng Hospital, Taishan Medical University, Shandong, People's Republic of ChinaAbstract: Stem cell transplantation is one of the potential treatments for neurological disorders. Since human umbilical cord stem cells have been shown to provide neuroprotection and promote neural regeneration, we have attempted to transplant the human umbilical cord blood mononuclear cells (hUCB-MNCs to treat patients with delayed encephalopathy after carbon monoxide intoxication (DEACOI. The hUCB-MNCs were isolated from fresh umbilical cord blood and were given to patients subarachnoidally. Physical examinations, mini-mental state examination scores, and computed tomography scans were used to evaluate the improvement of symptoms, signs, and pathological changes of the patient's brain before and after hUCB-MNC transplantation. A total of 12 patients with DEACOI were treated with hUCB-MNCs in this study. We found that most of the patients have shown significant improvements in movement, behavior, and cognitive function, and improved brain images in 1–4 months from the first transplantation of hUCB-MNCs. None of these patients have been observed to have any severe adverse effects. Our study suggests that the hUCB-MNC transplantation may be a safe and effective treatment for DEACOI. Further studies and clinical trials with more cases, using more systematic scoring methods, are needed to evaluate brain structural and functional improvements in patients with DEACOI after hUCB-MNC therapy.Keywords: human umbilical cord blood mononuclear cells, transplantation, delayed encephalopathy after carbon monoxide intoxication, MMSE

  6. A Randomized Controlled Trial of Puncturing and Bloodletting at Twelve Hand Jing Points to Treat Acute Carbon Monoxide Poisoning as Adjunct to First Aid Treatment: A Study Protocol

    Directory of Open Access Journals (Sweden)

    Ying Yue

    2015-01-01

    Full Text Available Background. Acute carbon monoxide poisoning (ACOP is a significant cause of morbidity and mortality in many countries. Twelve Hand Jing Points (THJP have been believed to be effective to treat all kinds of emergency calls in traditional Chinese medicine (TCM for more than 3000 years. This randomized controlled trial (RCT is designed to evaluate the effectiveness of THJP in curing acute carbon monoxide poisoning in first aid treatment. This paper reports the protocol of the trial. Methods/Design. This RCT is a multicenter, randomized, controlled study undergoing in China. The compliant patients are divided into the bloodletting group and standard of care group. With first aid treatments given to both of the groups, the bloodletting group is bleeding at THJP upon being hospitalized. Primary outcomes and secondary outcomes will be measured and compared between these two groups. Before treatment, immediately after treatment, and 30 minutes, 1 hour, and 4 hours after treatment, patients’ basic vital signs and state of consciousness were observed. Before treatment and 1 and 4 hours after treatment, carboxyhemoglobin concentration in venous blood samples was detected. Discussion. The objective of this study is to provide convincing evidence to clarify the efficacy and safety of THJP for early treatment of acute carbon monoxide poisoning.

  7. Iodine monoxide in the north subtropical free troposphere [Discussion paper

    OpenAIRE

    Puentedura, Olga; Gil-Ojeda, Manuel; Saiz-Lopez, Alfonso; Hay, Tim; Navarro Comas, Mónica; Gómez Peláez, Ángel Jesús; Cuevas Agulló, Emilio; Iglesias, J.

    2011-01-01

    Iodine monoxide (IO) was retrieved using a new multi-axis DOAS instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and is hence representative of the free troposphere. We report daily observations from May to August 2010 at different viewing angles. During this period, t...

  8. Status epilepticus and cardiopulmonary arrest in a patient with carbon monoxide poisoning with full recovery after using a neuroprotective strategy: a case report

    Directory of Open Access Journals (Sweden)

    Abdulaziz Salman

    2012-12-01

    Full Text Available Abstract Introduction Carbon monoxide poisoning can be associated with life-threatening complications, including significant and disabling cardiovascular and neurological sequelae. Case presentation We report a case of carbon monoxide poisoning in a 25-year-old Saudi woman who presented to our facility with status epilepticus and cardiopulmonary arrest. Her carboxyhemoglobin level was 21.4 percent. She made a full recovery after we utilized a neuroprotective strategy and normobaric oxygen therapy, with no delayed neurological sequelae. Conclusions Brain protective modalities are very important for the treatment of complicated cases of carbon monoxide poisoning when they present with neurological toxicities or cardiac arrest. They can be adjunctive to normobaric oxygen therapy when the use of hyperbaric oxygen is not feasible.

  9. Recent changes in atmospheric carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Masarie, K.A. (Univ. of Colorado, Boulder, CO (United States)); Tans, P.P.; Lang, P.M. (National Oceanic and Atmospheric Administration, Boulder, CO (United States))

    1994-03-18

    Measurements of carbon monoxide (CO) in air samples collected from 27 locations between 71[degrees]N and 41[degrees]S show that atmospheric levels of this gas have decreased worldwide over the past 2 to 5 years. During this period, CO decreased at nearly a constant rate in the high northern latitudes. In contrast, in the tropics an abrupt decrease occurred beginning at the end of 1991. In the Northern Hemisphere, CO decreased at a spatially and temporally averaged rate of 7.3 ([+-]0.9) parts per billion per year (6.1 percent per year) from June 1990 to June 1993, whereas in the Southern Hemisphere, CO decreased 4.2 ([+-]0.5) parts per billion per year (7.0 percent per year). This recent change is opposite a long-term trend of a 1 to 2 percent per year increase inferred from measurements made in the Northern Hemisphere during the past 30 years.

  10. Vibrationally Excited Carbon Monoxide Produced via a Chemical Reaction Between Carbon Vapor and Oxygen

    Science.gov (United States)

    Jans, Elijah R.; Eckert, Zakari; Frederickson, Kraig; Rich, Bill; Adamovich, Igor V.

    2017-06-01

    Measurements of the vibrational distribution function of carbon monoxide produced via a reaction between carbon vapor and molecular oxygen has shown a total population inversion on vibrational levels 4-7. Carbon vapor, produced using an arc discharge to sublimate graphite, is mixed with an argon oxygen flow. The excited carbon monoxide is vibrationally populated up to level v=14, at low temperatures, T=400-450 K, in a collision-dominated environment, 15-20 Torr, with total population inversions between v=4-7. The average vibrational energy per CO molecule formed by the reaction is 0.6-1.2 eV/molecule, which corresponds to 10-20% of the reaction enthalpy. Kinetic modeling of the flow reactor, including state specific vibrational processes, was performed to infer the vibrational distribution of the products of the reaction. The results show viability of developing of a new chemical CO laser from the reaction of carbon vapor and oxygen.

  11. Computed tomography of delayed encephalopathy of acute carbon monoxide poisoning - correlation with clinical findings -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Chung, Sung Hoon; Choo, In Wook; Chang, Kee Hyun

    1986-01-01

    Cerebral computed tomography (CT) findings were described in twenty-six cases with the late sequelae of acute carbon monoxide poisoning and were computed with the neurological symptoms and signs. The CT findings include symmetrical periventricular white matter low density in five cases, globes pallidus low density in six cases, ventricular dilatation in seven cases, ventricular dilatation and sulci widening in three cases, and normal findings in ten cases. Only one case showed low densities in both periventricular white matter and globes pallidus. Late sequelae of the interval from of carbon monoxide poisoning were clinically categorized as cortical dysfunction, parkinsonian feature, and cerebella dysfunction. The severity of the clinical symptoms and signs of neurological sequelae is generally correlated with presence and multiplicity of abnormal brain CT findings. But of fourteen cases showing the parkinsonian feature, only five cases had low density of globes pallidus in brain CT. Another case showing small unilateral low density of globes pallidus had no parkinsonian feature but showed mild cortical dysfunction.

  12. The chest X-ray in pulmonary capillary haemorrhage: correlation with carbon monoxide uptake

    International Nuclear Information System (INIS)

    Bowley, N.B.; Hughes, J.M.B.; Steiner, R.E.

    1979-01-01

    Serial changes in carbon monoxide uptake (Ksub(CO) or Dsub(L)CO/VA) were used to monitor episodes of pulmonary capillary haemorrhage in Goodpasture's syndrome (13 cases), immune complex nephritis (three cases) and idiopathic haemosiderosis (one case). Air-space shadowing on the chest X-ray (on a scoring system 0 to 12) was assessed in the light of the changes of Ksub(CO). In 14 out of 27 episodes of bleeding, the rise and fall of Ksub(CO) was matched in time by the appearance and disappearance of air-space shadowing on the chest X-ray. In six episodes the chest X-ray remained normal despite a rise of Ksub(CO). In two cases air-space shadowing appeared up to 48 h after the rise of Ksub(CO). On five occasions chest X-ray abnormalities preceded the rise of Ksub(CO) but chest infection or fluid overload accounted for three of these. In cases with suspected pulmonary capillary haemorrhage, measurements of carbon monoxide uptake will provide additional information and will assist in the interpretation of the chest X-ray. (author)

  13. Acute carbon monoxide intoxication : the relation between MR findings and clinical outcome

    International Nuclear Information System (INIS)

    Chang, Jin Bae; Jeong, Hae Woong; Kim, Ki Nam; Kim, Dong Wook; Kim, Chang Soo

    1999-01-01

    To analyse MR findings of various involving sites and the relation between such findings and clinical outcome, the authors retrospectively reviewed MR images of acute carbon monoxide intoxication. In 12 patients, MR images obtained from several hours to 12 days after acute carbon monoxide intoxication were reviewed. The images were analysed with regard to involved sites, symmetricity, signal intensity, and the presence or absence of hemorrhage, and the relationship between MR findings and clinical outcome; the presence of delayed encephalopathy was then determined. The globus pallidus(n=9), white matter(n=3), [centrum semiovale(n=2), periventricular white matter(n=1)] and gyrus(n=6) [inferior temporal gyrus(n=2), cingulate gyrus(n=1), precentral gyrus(n=1), hippocampal gyrus(n=1), parahippocampal gyrus(n=1)] were typically involved, and there was also involvenent of the corpus callosum(n=3), thalamus(n=2) and midbrain(n=2). All lesions of the globus pallidus, thalamus, midbrain and temporal lobe were bilaterally symmetric. In all these cases, subtle or prominent low signal intensity was seen on spin-echo T1WI, and high signal intensity on PDWI and T2WI. Some lesions of the globus pallidus(n=1), thalamus(n=1) and midbrain(n=1) were associated with hemorrhage, which occurred during the early subacute stage and was seen on high/low signal intensity T1/T2WI images. Acute cerebral(n=1) and cerebellar(n=1) infarctions were also seen. Cerebral white matter involvement correlated with poor clinical outcome, and in two cases, delayed encephalopathy developed. In these cases of acute carbon monoxide intoxication, the globus pallidus, white matter, cortex and hippocampus were frequently involved, and there was also involvement of various sites such as the corpus callosum, thalamus and midbrain. Lesions of the temporal lobe, thalamus and midbrain were bilaterally symmetric. The involvement of cerebral white matter and the presence of delayed encephalopathy can influence

  14. Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report.

    Science.gov (United States)

    Herren, Thomas; Achermann, Eva; Hegi, Thomas; Reber, Adrian; Stäubli, Max

    2017-07-28

    Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxygenation and to avoid carbon dioxide rebreathing. A 72-year-old Caucasian man with severe chronic obstructive pulmonary disease was admitted to the emergency department because of worsening dyspnea and an oxygen saturation of 81% measured by pulse oximetry. Oxygen was administered using a non-rebreathing mask with an oxygen reservoir bag attached. For fear of removing the hypoxic stimulus to respiration the oxygen flow was inappropriately limited to 4L/minute. The patient developed carbon dioxide narcosis and had to be intubated and mechanically ventilated. Non-rebreathing masks with oxygen reservoir bags must be fed with an oxygen flow exceeding the patient's minute ventilation (>6-10 L/minute.). If not, the amount of oxygen delivered will be too small to effectively increase the arterial oxygen saturation. Moreover, the risk of carbon dioxide rebreathing dramatically increases if the flow of oxygen to a non-rebreathing mask is lower than the minute ventilation, especially in patients with chronic obstructive pulmonary disease and low tidal volumes. Non-rebreathing masks (with oxygen reservoir bags) must be used cautiously by experienced medical staff and with an appropriately high oxygen flow of 10-15 L/minute. Nevertheless, arterial blood gases must be analyzed regularly for early detection of a rise in partial pressure of carbon dioxide in arterial blood in patients with chronic obstructive pulmonary disease and a hypoxic ventilatory drive. These patients are more safely managed using a nasal cannula with an oxygen flow of 1-2L/minute or a simple face mask with an oxygen flow of 5L/minute.

  15. Room-temperature cold-welding of gold nanoparticles for enhancing the electrooxidation of carbon monoxide.

    Science.gov (United States)

    Liu, Cai; Li, Yong-Jun; Sun, Shi-Gang; Yeung, Edward S

    2011-04-21

    A cold-welding strategy is proposed to rapidly join together Au nanoparticles (AuNPs) into two-dimensional continuous structures for enhancing the electrooxidation of carbon monoxide by injecting a mixture of ethanol and tolulene into the bottom of a AuNP solution. © The Royal Society of Chemistry 2011

  16. Experimental study on surface wrinkling of silicon monoxide film on compliant substrate under thermally induced loads

    Science.gov (United States)

    Li, Chuanwei; Kong, Yingxiao; Jiang, Wenchong; Wang, Zhiyong; Li, Linan; Wang, Shibin

    2017-06-01

    The wrinkling of a silicon monoxide thin film on a compliant poly(dimethylsiloxane) (PDMS) substrate structure was experimentally investigated in this study. The self-expansion effect of PDMS during film deposition was utilized to impose a pretensile strain on the structure through a specially made fixture. A laser scanning confocal microscope (LSCM) system with an in situ heating stage was employed for the real-time measurement. The Young’s modulus of the silicon monoxide thin film as well as the PDMS substrate was measured on the basis of the elasticity theory. Moreover, the effects of temperature variations on geometric parameters in the postbuckling state, such as wavelength and amplitude, were analyzed. It was proved that wavelength is relatively immune to thermal loads, while amplitude is much more sensitive.

  17. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao

    2017-04-12

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  18. Thermal Degradation of Lead Monoxide Filled Polymer Composite Radiation Shields

    International Nuclear Information System (INIS)

    Harish, V.; Nagaiah, N.

    2011-01-01

    Lead monoxide filled Isophthalate resin particulate polymer composites were prepared with different filler concentrations and investigated for physical, thermal, mechanical and gamma radiation shielding characteristics. This paper discusses about the thermo gravimetric analysis of the composites done to understand their thermal properties especially the effect of filler concentration on the thermal stability and degradation rate of composites. Pristine polymer exhibits single stage degradation whereas filled composites exhibit two stage degradation processes. Further, the IDT values as well as degradation rates decrease with the increased filler content in the composite.

  19. Microbial fuel cell-based biosensor for toxic carbon monoxide monitoring

    DEFF Research Database (Denmark)

    Zhou, Shaofeng; Huang, Shaobin; Li, Yi

    2018-01-01

    This study presents an innovative microbial fuel cell-based biosensor for carbon monoxide (CO) monitoring. The hypothesis for the function of the biosensor is that CO inhibits bacterial activity in the anode and thereby reduces electricity production. A mature electrochemically active biofilm...... increasing CO concentration over 70%. Besides, the response time of the biosensor was 1 h. The compact design and simple operation of the biosensor makes it easy to be integrated in existing CO-based industrial facilities either as a forewarning sensor for CO toxicity or even as an individual on...

  20. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  1. Evidence for long-range transport of carbon monoxide in the Southern Hemisphere from SCIAMACHY observations

    NARCIS (Netherlands)

    Gloudemans, A.M.S.; Krol, M.C.; Meirink, J.F.; de Laat, A.T.J.; van der Werf, G.R.; Schrijver, H.; van den Broek, M.M.P.; Aben, I.

    2006-01-01

    The SCIAMACHY satellite instrument shows enhanced carbon monoxide (CO) columns in the Southern Hemisphere during the local Spring. Chemistry-transport model simulations using the new GFEDv2 biomass-burning emission database show a similar temporal and spatial CO distribution, indicating that the

  2. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    Science.gov (United States)

    2012-02-14

    ... a SIP means that transportation activities will not produce new air quality violations, worsen... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY... Transportation & Public Facilities, and the U.S. Department of Transportation will be required to use [[Page 8253...

  3. Study of Hopcalite (CuMnOx) Catalysts Prepared Through A Novel Route for the Oxidation of Carbon Monoxide at Low Temperature

    OpenAIRE

    Subhashish Dey; Ganesh Chandra Dhal; Devendra Mohan; Ram Prasad

    2017-01-01

    Carbon monoxide (CO) is a poisonous gas, recognized as a silent killer. The gas is produced by incomplete combustion of carbonaceous fuel. Recent studies have shown that hopcalite group is one of the promising catalysts for CO oxidation at low temperature. In this study, hopcalite (CuMnOx) catalysts were prepared by KMnO4 co-precipitation method followed by washing, drying the precipitate at different temperatures (22, 50, 90, 110, and 120 oC) for 12 h in an oven and subsequent calcination at...

  4. Comparison of the effectiveness of high flow nasal oxygen cannula vs. standard non-rebreather oxygen face mask in post-extubation intensive care unit patients.

    Science.gov (United States)

    Brotfain, Evgeni; Zlotnik, Alexander; Schwartz, Andrei; Frenkel, Amit; Koyfman, Leonid; Gruenbaum, Shaun E; Klein, Moti

    2014-11-01

    Optimal oxygen supply is the cornerstone of the management of critically ill patients after extubation, especially in patients at high risk for extubation failure. In recent years, high flow oxygen system devices have offered an appropriate alternative to standard oxygen therapy devices such as conventional face masks and nasal prongs. To assess the clinical effects of high flow nasal cannula (HFNC) compared with standard oxygen face masks in Intensive Care Unit (ICU) patients after extubation. We retrospectively analyzed 67 consecutive ventilated critical care patients in the ICU over a period of 1 year. The patients were allocated to two treatment groups: HFNC (34 patients, group 1) and non-rebreathing oxygen face mask (NRB) (33 patients, group 2). Vital respiratory and hemodynamic parameters were assessed prior to extubation and 6 hours after extubation. The primary clinical outcomes measured were improvement in oxygenation, ventilation-free days, re-intubation, ICU length of stay, and mortality. The two groups demonstrated similar hemodynamic patterns before and after extubation. The respiratory rate was slightly elevated in both groups after extubation with no differences observed between groups. There were no statistically significant clinical differences in PaCO2. However, the use of HFNC resulted in improved PaO2/FiO2 post-extubation (P < 0.05). There were more ventilator-free days in the HFNC group (P< 0.05) and fewer patients required reintubation (1 vs. 6). There were no differences in ICU length of stay or mortality. This study demonstrated better oxygenation for patients treated with HFNC compared with NRB after extubation. HFNC may be more effective than standard oxygen supply devices for oxygenation in the post-extubation period.

  5. Carbon Monoxide Epidemic Among Immigrant Populations: King County, Washington, 2006

    Science.gov (United States)

    Kwan-Gett, Tao; Hampson, Neil B.; Baer, Atar; Shusterman, Dennis; Shandro, Jamie R.; Duchin, Jeffrey S.

    2009-01-01

    Objectives. We investigated an outbreak of carbon monoxide (CO) poisoning after a power outage to determine its extent, identify risk factors, and develop prevention measures. Methods. We reviewed medical records and medical examiner reports of patients with CO poisoning or related symptoms during December 15 to 24, 2006. We grouped patients into households exposed concurrently to a single source of CO. Results. Among 259 patients with CO poisoning, 204 cases were laboratory confirmed, 37 were probable, 10 were suspected, and 8 were fatal. Of 86 households studied, 58% (n = 50) were immigrant households from Africa (n = 21), Asia (n = 15), Latin America (n = 10), and the Middle East (n = 4); 34% (n = 29) were US-born households. One percent of households was European (n = 1), and the origin for 7% (n = 6) was unknown. Charcoal was the most common fuel source used among immigrant households (82%), whereas liquid fuel was predominant among US-born households (34%). Conclusions. Educational campaigns to prevent CO poisoning should consider immigrants’ cultural practices and languages and specifically warn against burning charcoal indoors and incorrect ventilation of gasoline- or propane-powered electric generators. PMID:19608962

  6. Exposure to carbon monoxide, respirable suspended particulates, and volatile organic compounds while commuting by bicycle

    International Nuclear Information System (INIS)

    Bevan, M.A.J.; Proctor, C.J.; Baker-Rogers, J.; Warren, N.D.

    1991-01-01

    A portable air sampling system has been used to assess exposures to various substances while commuting by bicycle in an urban area. The major source of pollutants in this situation is motor vehicle exhaust emissions. Carbon monoxide, measured by electrochemical detection, was found at peak concentrations in excess of 62 ppm, with mean values over 16 individual 35-mm journeys being 10.5 ppm. Respirable suspended particulates, averaged over each journey period, were found at higher concentrations (mean 130 μg m -3 ) than would be expected in indoor situations. Mean exposure to benzene (at 56 μg m -3 ) and other aromatic volatile organic compounds was also relatively high. The influence of wind conditions on exposure was found to be significant. Commuting exposures to carbon monoxide, respirable suspended particulates, and aromatic VOCs were found to be higher than exposures in a busy high street and on common parkland

  7. Methods and systems for producing syngas

    Science.gov (United States)

    Hawkes, Grant L; O& #x27; Brien, James E; Stoots, Carl M; Herring, J. Stephen; McKellar, Michael G; Wood, Richard A; Carrington, Robert A; Boardman, Richard D

    2013-02-05

    Methods and systems are provided for producing syngas utilizing heat from thermochemical conversion of a carbonaceous fuel to support decomposition of at least one of water and carbon dioxide using one or more solid-oxide electrolysis cells. Simultaneous decomposition of carbon dioxide and water or steam by one or more solid-oxide electrolysis cells may be employed to produce hydrogen and carbon monoxide. A portion of oxygen produced from at least one of water and carbon dioxide using one or more solid-oxide electrolysis cells is fed at a controlled flow rate in a gasifier or combustor to oxidize the carbonaceous fuel to control the carbon dioxide to carbon monoxide ratio produced.

  8. UV-induced carbon monoxide emission from living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2013-01-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop...... to either an ecosystem chamber or a plant-leaf scale chamber. Leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation as well as the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature......, indicating an abiotic process. The emission of CO in response to the UV-component of natural solar radiation was also evident at the ecosystem scale....

  9. Study on serum metabonomics of rats exposed to low-dose ionizing radiation, carbon monoxide, benzene and noise

    Directory of Open Access Journals (Sweden)

    Qing-rong WANG

    2015-07-01

    Full Text Available Objective To investigate the combined effects of low-dose ionizing radiation, carbon monoxide, benzene and noise on serum metabolites and the mechanism of injury induced by these complex environmental factors in rats. Methods  Sixteen adult SD rats were randomly divided into control group and exposed group (8 each. The exposed group received the combined effect every day for 7 days. At the end of experiment, sera were collected from the abdominal aorta of rats. The metabolic fingerprint of serum was obtained by 1H nuclear magnetic resonance (1H NMR spectroscopy and determined with pattern recognition techniques of principal component analysis (PCA and orthogonal signal correction-partial least squares (OSC-PLS. The similarities and differences in metabolic profiles between two groups were visualized by SIMCA-P software. Results The rat serum 1H NMR spectra revealed different metabolic spectra between the control group and exposed group. The OSC-PLS plots of the serum samples presented respectively marked clustering between the two groups. Compared with the control group, the contents of lipid, high density lipoprotein, glycine/glucose, N-acetyl glycoprotein 1, N-acetyl glycoprotein 2, phosphatidyl choline and unsaturated fatty acid increased, while those of lactic acid, threonine/lipid, alanine, creatine, glycerylphosphorylcholine/ trimethylamine oxide, low density lipoprotein/high density lipoprotein, low density lipoprotein, very low density lipoprotein/ low density lipoprotein, very low density lipoprotein and saturated fatty acid decreased. Conclusions Combination of low-dose ionizing radiation, carbon monoxide, benzene and noise could induce changes of serum metabolites in rats, involving in immune function, renal function and energy metabolism. The NMR-based-metabonomics method has potential of application in research on combined biological effects of the complex environmental factors. DOI: 10.11855/j.issn.0577-7402.2015.07.09

  10. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad

    2018-05-07

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm at combustion relevant conditions. Off-axis alignment and rapid intra-pulse down-chirp resulted in effective suppression of cavity noise.

  11. Catalytic Reduction of Nitrous Oxide with Carbon Monoxide over Calcined Co–Mn–Al Hydrotalcite

    Czech Academy of Sciences Publication Activity Database

    Pacultová, K.; Obalová, L.; Kovanda, F.; Jirátová, Květa

    2008-01-01

    Roč. 137, 2-4 (2008), s. 358-389 ISSN 0920-5861 R&D Projects: GA ČR(CZ) GA106/05/0366 Institutional research plan: CEZ:AV0Z40720504 Keywords : nitrous oxide * carbon monoxide * mixed oxide catalysts Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.004, year: 2008

  12. Variations of time-to-incapacitation and carboxyhemoglobin values in rats exposed to two carbon monoxide concentrations.

    Science.gov (United States)

    1993-05-01

    It has been suggested that passenger protective breathing equipment protect aircraft passengers from smoke for 5 min during an evacuation phase and for 35 min during an in-flight-plus-evacuation phase. Carbon monoxide (CO) is one of the most abundant...

  13. Carbon monoxide budget in the northern hemisphere

    Energy Technology Data Exchange (ETDEWEB)

    Bakwin, P.S.; Tans, P.P. (Climate Monitoring and Diagnostics Lab., Boulder, CO (United States)); Novelli, P.C. (Univ. of Colorado, Boulder, CO (United States))

    1994-03-15

    To improve urban air quality the major industrialized nations of the West took steps during the 1970s and 1980s to reduce carbon monoxide (CO) emissions from automobiles and other industrial sources. Overall, CO/CO[sub 2] emission ratios from the mix of fossil fuel combustion sources have been reduced by about half during 1976-1990. Also, the tropospheric abundance of hydroxyl radical (OH), which is the main sink for CO, is proposed to have increased globally by about 1.0 [+-] 0.8% yr[sup [minus]1]. The authors use a simple two-box model to examine the impact of shrinking emissions and increasing OH on the global abundance of CO. They find that these factors contribute about equally in reducing CO levels in the Northern Hemisphere troposphere by about 1.8 [+-] 0.8 ppb yr[sup [minus]1] on average. 19 refs., 1 fig.

  14. Carbon Monoxide Fumigation Improved the Quality, Nutrients, and Antioxidant Activities of Postharvest Peach

    Science.gov (United States)

    Li, Ying; Pei, Fei

    2014-01-01

    Peaches (Prunus persica cv. Yanhong) were fumigated with carbon monoxide (CO) at 0, 0.5, 5, 10, and 20 μmol/L for 2 hours. The result showed that low concentration CO (0.5–10 μmol/L) might delay the decrease of firmness and titrable acid content, restrain the increase of decay incidence, and postpone the variation of soluble solids content, but treating peaches with high concentration CO (20 μmol/L) demonstrated adverse effects. Further research exhibited that exogenous CO could induce the phenylalnine ammonialyase activity, maintain nutrient contents such as Vitamin C, total flavonoid, and polyphenol, and enhance antioxidant activity according to reducing power and 2,2-diphenyl-1-(2,4,6-trinitrophenyl) hydrazyl radical scavenging activity. Treating peaches with appropriate concentration CO was beneficial to the quality, nutrients, and antioxidant activity of postharvest peaches during storage time. Therefore, CO fumigation might probably become a novel method to preserve postharvest peach and other fruits in the future. PMID:26904651

  15. Effect of Carbon Monoxide on Active Oxygen Metabolism of Postharvest Jujube

    OpenAIRE

    Shaoying Zhang; Qin Li; Yulan Mao

    2014-01-01

    To prolong the shelf life postharvest jujube, the effect of carbon monoxide (CO) on senescence of postharvest jujube in relation to active oxygen metabolism was investigated. Jujubes were fumigated with CO gas at 5, 10, 20 or 40μmol/L for 1 h, and then stored for 30 days at room temperature. Changes in membrane permeability, malonaldehyde (MDA), H2O2, O2•− content, and activities of active oxygen metabolism associated enzymes including superoxide dismutase (SOD), catalase (CAT) and peroxidase...

  16. A Southern Hemisphere atmospheric history of carbon monoxide from South Pole firn air

    Science.gov (United States)

    Verhulst, K. R.; Aydin, M.; Novelli, P. C.; Holmes, C. D.; Prather, M. J.; Saltzman, E. S.

    2013-12-01

    Carbon monoxide (CO) is a reactive trace gas and is important to tropospheric photochemistry as a major sink of hydroxyl radicals (OH). Major sources of CO are fossil fuel combustion, linked mostly to automotive emissions, biomass burning, and oxidation of atmospheric methane. Understanding changes in carbon monoxide over the past century will improve our understanding of man's influence on the reactivity of the atmosphere. Little observational information is available about CO levels and emissions prior to the 1990s, particularly for the Southern Hemisphere. The NOAA global flask network provides the most complete instrumental record of CO, extending back to 1988. Annually averaged surface flask measurements suggest atmospheric CO levels at South Pole were relatively stable from 2004-2009 at about 51 nmol mol-1 [Novelli and Masarie, 2013]. In this study, a 20th century atmospheric history of CO is reconstructed from South Pole firn air measurements, using a 1-D firn air diffusion model. Firn air samples were collected in glass flasks from two adjacent holes drilled from the surface to 118 m at South Pole, Antarctica during the 2008/2009 field season and CO analysis was carried out by NOAA/CCG. Carbon monoxide levels increase from about 45 nmol mol-1 in the deepest firn sample at 116 m to 52 nmol mol-1 at 107 m, and remain constant at about 51-52 nmol mol-1 at shallower depths. Atmospheric histories based on the firn air reconstructions suggest that CO levels over Antarctica increased by roughly 40% (from about 36 to 50 nmol mol-1) between 1930-1990, at a rate of about 0.18 nmol mol-1 yr-1. Firn air and surface air results suggest the rate of CO increase at South Pole slowed considerably after 1990. The firn air-based atmospheric history is used to infer changes in Southern Hemisphere CO emissions over the 20th century.

  17. Carbon monoxide (CO) intoxication: Computerized tomography and magnetic resonance

    International Nuclear Information System (INIS)

    Benitez Gomez, S.; Aguilera Navarro, J.M.; Gonzalez Garcia, A.; Gonzalez Marcos, J.R.; Fernandez Cruz, J.

    1993-01-01

    We present a case of acute carbon monoxide (CO) intoxication in a previously healthy 13-year-old girl, who was found in the bathroom, unconscious and with the gas-burning hot water thank operating. The neuroradiological study showed bilateral, symmetrical cortical and subcortical parietooccipital and temporal lesions as well as damage to the basal lymph nodes. These lesions were related to the anoxic situation induced by this type of intoxication. Clinicoradiological follow-up included CT and MR sequences over a period of 10 months. In this cases, we stress the greater sensitivity of MR in the early detection of the characteristic lesions in this situation and we analyze the evolution of the process. (Author)

  18. Preparation and crystal structure of carbonyltris (diethyldithiocarbamato) technetium (III): an unexpected source of co-ordinated carbon monoxide

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Pojer, P.M.; Williams, G.A.

    1981-10-01

    Tc(S 2 CNEt 2 ) 3 CO has been prepared by the reduction of NH 4 TcO 4 with formamidinesulphinic acid in the presence of NaS 2 CNEt 2 . It is suggested that the co-ordinated carbon monoxide is formed after co-ordination of formamidinesulphinic acid, or some decomposition product, with technetium. The crystal structure of Tc(S 2 CNEt 2 ) 3 CO has been determined by single-crystal X-ray diffraction methods at 17 deg. C. Diffractometry has provided significant Bragg intensities for 2045 independent reflections and the structure has been refined by full-matrix least-squares methods to R 0.049. The compound is isostructural with the rhenium analogue and consists of discrete Tc(S 2 CNEt 2 ) 3 CO molecules, each containing a terminal linear CO group. The technetium atom has a seven co-ordinate environment which is best described as a distorted pentagonal bipyramid

  19. Electrocatalytic oxidation of carbon monoxide

    Directory of Open Access Journals (Sweden)

    Manuel de Jesus Santiago Farias

    2009-01-01

    Full Text Available Este trabalho discute alguns aspectos importantes relacionados à reação de eletrooxidação do monóxido de carbono sobre monocristais de platina, em meio ácido. Aspectos mecanísticos são discutidos em termos da formação das estruturas compactas que o CO forma quando este é adsorvido. As principais idéias aqui apresentadas, levam em consideração as existências dessas estruturas. Os clássicos mecanismos Lagmuir-Hinshelwood e Eley-Rideal são aqui discutidos, especialmente o primeiro considerando a mobilidade do CO e também a nucleação e crescimento de ilhas formadas por espécies adsorvidas contendo oxigênio.////////// This work discusses some important aspects related to the carbon monoxide electrooxidation reaction on Pt single crystal electrodes in acidic media. The mechanistic aspects are discussed in terms of the formation of compact structures developed when CO is adsorbed. The main ideas presented here are focused on the mechanistic aspects that take into account the existence of such structures. The classical kinetic mechanisms of Lagmuir-Hinshelwood and Eley-Rideal are discussed considering the superficial mobility of CO or nucleation-growing of islands formed by oxygen-containing adsorbates.

  20. Pattern recognition methods in air pollution control

    Energy Technology Data Exchange (ETDEWEB)

    Tauber, S

    1978-01-01

    The use of pattern recognition methods for predicting air pollution developments is discussed. Computer analysis of historical pollution data allows comparison in graphical form. An example of crisis prediction for carbon monoxide concentrations, using the pattern recognition method of analysis, is presented. Results of the analysis agreed well with actual CO conditions. (6 graphs, 4 references, 1 table)

  1. An infrared spectroscopic study of the adsorption of carbon monoxide on silica-supported copper particles

    NARCIS (Netherlands)

    Jong, K.P. de; Geus, John W.; Joziasse, J.

    Infrared spectroscopy is used to study the adsorption of carbon monoxide (20°C; 0.1– 100 Torr) on copper-on-silica catalysts differently prepared and pretreated. As determined by electron microscopy and X-ray line broadening, the catalysts contain copper particles having sizes of 60 to 5000 Å

  2. [Estimation of carbon monoxide poisonings frequency, based on carboxyhemoglobin determinations performed in Toxicology Laboratory in Krakow in years 2002-2010].

    Science.gov (United States)

    Gomółka, Ewa; Gawlikowski, Tomasz

    2011-01-01

    Carboxyhemoglobin is a specific biomarker of carbon monoxide (CO) exposition. The source of CO indoors are most often gas, oil or carbon furnaces and stoves or bathroom gas heaters. CO intoxication during fire or exposition to car fumes are sporadic. The aim of the study was: to present the frequency of CO intoxications diagnosed in Laboratory of Analytical Toxicology UJ Collegium Medicum in years 2002 - 2010, to present the season trends of CO intoxications, show sex and age structure of CO intoxicated patients. Material were Laboratory of Analytical Toxicology and Drug Monitoring data records from years 2002 - 2010. CO intoxication was confirmed and recognized when COHb blood concentration was higher than 10%. Annual number of CO poisonings was stable in the period of time, varied from 209 to 296 (mean 256,2 CO poisonings per year). Sex structure of CO poisoned patients showed little female dominance (54.6%). Carbon monoxide poisonings distribution was seasonal. The season of intensified CO intoxications lasted from October to March, the highest intensity was in December and January. The CO poisoning problem is still actual. Society education about security, recognition, diagnosis and practice in carbon monoxide exposition is still needful.

  3. Increased ultrafine particles and carbon monoxide concentrations are associated with asthma exacerbation among urban children

    Science.gov (United States)

    Evans, Kristin A.; Halterman, Jill S.; Hopke, Philip K.; Fagnano, Maria; Rich, David Q.

    2014-01-01

    Objectives Increased air pollutant concentrations have been linked to several asthma-related outcomes in children, including respiratory symptoms, medication use, and hospital visits. However, few studies have examined effects of ultrafine particles in a pediatric population. Our primary objective was to examine the effects of ambient concentrations of ultrafine particles on asthma exacerbation among urban children and determine whether consistent treatment with inhaled corticosteroids could attenuate these effects. We also explored the relationship between asthma exacerbation and ambient concentrations of accumulation mode particles, fine particles (≤ 2.5 micrograms [μm]; PM2.5), carbon monoxide, sulfur dioxide, and ozone. We hypothesized that increased 1 to 7 day concentrations of ultrafine particles and other pollutants would be associated with increases in the relative odds of an asthma exacerbation, but that this increase in risk would be attenuated among children receiving school-based corticosteroid therapy. Methods We conducted a pilot study using data from 3–10 year-old children participating in the School-Based Asthma Therapy trial. Using a time-stratified case-crossover design and conditional logistic regression, we estimated the relative odds of a pediatric asthma visit treated with prednisone (n=96 visits among 74 children) associated with increased pollutant concentrations in the previous 7 days. We re-ran these analyses separately for children receiving medications through the school-based intervention and children in a usual care control group. Results Interquartile range increases in ultrafine particles and carbon monoxide concentrations in the previous 7 days were associated with increases in the relative odds of a pediatric asthma visit, with the largest increases observed for 4-day mean ultrafine particles (interquartile range=2088 p/cm3; OR=1.27; 95% CI=0.90–1.79) and 7-day mean carbon monoxide (interquartile range=0.17 ppm; OR=1.63; 95

  4. Retinoic acid-induced alveolar cellular growth does not improve function after right pneumonectomy.

    Science.gov (United States)

    Dane, D Merrill; Yan, Xiao; Tamhane, Rahul M; Johnson, Robert L; Estrera, Aaron S; Hogg, Deborah C; Hogg, Richard T; Hsia, Connie C W

    2004-03-01

    To determine whether all-trans retinoic acid (RA) treatment enhances lung function during compensatory lung growth in fully mature animals, adult male dogs (n = 4) received 2 mg x kg(-1) x day(-1) po RA 4 days/wk beginning the day after right pneumonectomy (R-PNX, 55-58% resection). Litter-matched male R-PNX controls (n = 4) received placebo. After 3 mo, transpulmonary pressure (TPP)-lung volume relationship, diffusing capacities for carbon monoxide and nitric oxide, cardiac output, and septal volume (V(tiss-RB)) were measured under anesthesia by a rebreathing technique at two lung volumes. Lung air and tissue volumes (V(air-CT) and V(tiss-CT)) were also measured from high-resolution computerized tomographic (CT) scans at a constant TPP. In RA-treated dogs compared with controls, TPP-lung volume relationships were similar. Diffusing capacities for carbon monoxide and nitric oxide were significantly impaired at a lower lung volume but similar at a high lung volume. Whereas V(tiss-RB) was significantly lower at both lung volumes in RA-treated animals, V(air-CT) and V(tiss-CT) were not different between groups; results suggest uneven distribution of ventilation consistent with distortion of alveolar geometry and/or altered small airway function induced by RA. We conclude that RA does not improve resting pulmonary function during the early months after R-PNX despite histological evidence of its action in enhancing alveolar cellular growth in the remaining lung.

  5. Method of and arrangement for extracting volatile bituminous condensable materials from shales, etc

    Energy Technology Data Exchange (ETDEWEB)

    Flodin, H G

    1918-06-22

    A method and arrangement for extracting volatile bituminous condensable materials, such as oils and similar material, as well as sulfur, whereby the material used is heated in a generator by introduction of a hot indifferent gas, such as carbon monoxide or generator gas, which is brought into circulation through a heating apparatus and the generator are characterized by removal of the shales distilled in the generator and their being charged into another generator or furnace where they are oxidized by means of air. Sulfur dioxide and carbon dioxide and possible carbon monoxide are formed and the sulfur dioxide and carbon dioxide formed by the oxidation of the distilled shales are brought into contact with hot coal for regeneration of sulfur and carbon monoxide. The patent contains five additional claims.

  6. Ambient carbon monoxide associated with alleviated respiratory inflammation in healthy young adults

    International Nuclear Information System (INIS)

    Zhao, Zhuohui; Chen, Renjie; Lin, Zhijing; Cai, Jing; Yang, Yingying; Yang, Dandan; Norback, Dan; Kan, Haidong

    2016-01-01

    There is increasing controversy on whether acute exposure to ambient carbon monoxide (CO) is hazardous on respiratory health. We therefore performed a longitudinal panel study to evaluate the acute effects of ambient CO on fractional exhaled nitric oxide (FeNO), a well-established biomarker of airway inflammation. We completed 4–6 rounds of health examinations among 75 healthy young adults during April to June in 2013 in Shanghai, China. We applied the linear mixed-effect model to investigate the short-term associations between CO and FeNO. CO exposure during 2–72 h preceding health tests was significantly associated with decreased FeNO levels. For example, an interquartile range increase (0.3 mg/m"3) of 2-h CO exposure corresponded to 10.6% decrease in FeNO. This association remained when controlling for the concomitant exposure to co-pollutants. This study provided support that short-term exposure to ambient CO might be related with reduced levels of FeNO, a biomarker of lower airway inflammation. - Highlights: • We completed 4–6 rounds of health examinations among 75 healthy young adults. • Short-term CO exposure was significantly associated with decreased FeNO levels. • The inverse association between CO and FeNO was robust controlling for co-pollutants. - Short-term exposure to ambient carbon monoxide may alleviate the respiratory inflammation.

  7. IR Laser Ablation of Silicon Monoxide in Gaseous Methanol and Hydrocarbons: Deposition of Polyoxocarbosilane

    Czech Academy of Sciences Publication Activity Database

    Dřínek, Vladislav; Bastl, Zdeněk; Šubrt, Jan; Pola, Josef

    2004-01-01

    Roč. 71, č. 2 (2004), s. 431-444 ISSN 0165-2370 R&D Projects: GA ČR GA203/00/1288 Institutional research plan: CEZ:AV0Z4072921; CEZ:AV0Z4032918; CEZ:AV0Z4040901 Keywords : silicon monoxide * reactive laser ablation * polyoxocarbosilane coatings Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 1.352, year: 2004

  8. Carbon monoxide inhibits omega-oxidation of leukotriene B4 by human polymorphonuclear leukocytes: evidence that catabolism of leukotriene B4 is mediated by a cytochrome P-450 enzyme.

    Science.gov (United States)

    Shak, S; Goldstein, I M

    1984-09-17

    Carbon monoxide significantly inhibits omega-oxidation of exogenous leukotriene B4 to 20-OH-leukotriene B4 and 20-COOH-leukotriene B4 by unstimulated polymorphonuclear leukocytes as well as omega-oxidation of leukotriene B4 that is generated when cells are stimulated with the calcium ionophore, A23187. Inhibition of omega-oxidation by carbon monoxide is concentration-dependent, completely reversible, and specific. Carbon monoxide does not affect synthesis of leukotriene B4 by stimulated polymorphonuclear leukocytes or other cell functions (i.e., degranulation, superoxide anion generation). These findings suggest that a cytochrome P-450 enzyme in human polymorphonuclear leukocytes is responsible for catabolizing leukotriene B4 by omega-oxidation.

  9. Content of carbon monoxide in the tissues of rats intoxicated with carbon monoxide in various conditions of acute exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sokal, J.A.; Majka, J.; Palus, J.

    1984-12-01

    Tissue carbon monoxide (CO) content was investigated in rats severely intoxicated with CO under various exposure conditions: 1% CO for 4 min, 0.4% CO for 40 min and 0.12% CO for 12 h. Extravascular CO was determined in the heart and skeletal muscles immediately after termination of exposure, and carboxymyoglobin (MbCO) percent saturation was calculated. Total brain CO was estimated immediately after termination of exposure and after the time periods of restitution. After the same exposure conditions, MbCO percent saturation was higher in the heart than in skeletal muscle. In both types of muscle, saturation on myoglobin (Mb) with CO depended on blood carboxyhemoglobin (HbCO) level and not on the duration of exposure. The time course of CO elimination was the same for blood and brain, irrespective of CO exposure conditions. The results obtained showed that acute CO intoxication induced by long duration exposures did not involve CO accumulation in the tissues.

  10. Thermodynamic properties of liquid mixtures of carbon monoxide and methane

    Energy Technology Data Exchange (ETDEWEB)

    Calado, J.C.G.; Guedes, H.J.R.; Nunes da Ponte, M.; Streett, W.B.

    1984-04-01

    Researchers conducted pressure-volume-temperature measurements of liquid methane at -230/sup 0/F and of six liquid mixtures of carbon monoxide and methane at -250/sup 0/, -240/sup 0/, and -230/sup 0/F from just above the saturation vapor pressure to the freezing pressure of methane. The excess volume proved to be large and negative at low pressures but less negative as the pressure increased, being almost zero at the highest pressure. Of the thermodynamic functions, excess enthalpy and excess entropy were much more sensitive to pressure than excess Gibbs energy. Conformal solution theory in the van der Waals one-fluid form reproduced the experimental results very successfully.

  11. Analysis of carbon monoxide production in multihundred-watt heat sources

    International Nuclear Information System (INIS)

    Peterson, D.E.; Mulford, R.N.R.

    1976-05-01

    The production of carbon monoxide observed within Multihundred Watt heat sources placed under storage conditions was analyzed. Results of compositional and isotopic analyses of gas taps performed on eight heat sources are summarized and interpreted. Several proposed CO generation mechanisms are examined theoretically and assessed by applying thermodynamic principles. Outgassing of the heat source graphite followed by oxygen isotopic exchange through the vent assemblies appears to explain the CO production at storage temperatures. Reduction of the plutonia fuel sphere by the CO is examined as a function of temperature and stoichiometry. Experiments that could be performed to investigate possible CO generation mechanisms are discussed

  12. Characteristics of autoignited laminar lifted flames in heated coflow jets of carbon monoxide/hydrogen mixtures

    KAUST Repository

    Choi, Byungchul

    2012-06-01

    The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process. © 2012 The Korean Society of Mechanical Engineers.

  13. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 1 (SRL1) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  14. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  15. Selective and efficient reduction of carbon dioxide to carbon monoxide on oxide-derived nanostructured silver electrocatalysts

    NARCIS (Netherlands)

    Ma, Ming; Trześniewski, Bartek J.; Xie, Jie; Smith, Wilson A.

    2016-01-01

    In this work, the selective electrocatalytic reduction of carbon dioxide to carbon monoxide on oxide-derived silver electrocatalysts is presented. By a simple synthesis technique, the overall high faradaic efficiency for CO production on the oxide-derived Ag was shifted by more than 400 mV towards a

  16. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...

  17. Toxicity of carbon monoxide hydrogen cyanide gas mixtures : exposure concentration, time to incapacitation, carboxyhemoglobin and blood cyanide parameters.

    Science.gov (United States)

    1994-04-01

    During aircraft interior fires, carbon monoxide (CO) and hydrogen cyanide (HCN) are produced in sufficient amounts to cause incapacitation and death. Time-to-incapacitation (ti) is a practical parameter for estimating escape time in fire environments...

  18. Carbon monoxide and coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Scheidemandel, V

    1974-01-01

    Studies on the relationship between increased carboxyhemoglobin levels in the blood and coronary heart disease in smokers and city dwellers are reviewed. The evidence of myocardial infarction is significantly higher in smokers than in nonsmokers which is due, apart from nicotine which promotes coronary arteriosclerosis, to inhaled carbon monoxide which leads to increased carboxyhemoglobin levels and most likely plays a role in the risk of arteriosclerosis and the coronary heart disease. Apart from combining with hemoglobin, CO increases the circulation rate and the coronary blood flow, and reduces the coronary arteriovenous oxygen difference, which is indicative of a reduced rate of oxygen extraction by the myocardium against an increased myocardial oxygen demand. The reduction of the oxygen extraction correlates with the increased COHb level. Inhaled CO lowers the threshold of angina pectoris due to the reduced myocardial oxygen tension. Also, considerable reduction of the oxygen diffusion from the capillaries toward the mitochondria due to the combination of CO with myoglobin is observed. Chronically increased CO levels in the blood and tissues not only accelerate the development of arteriosclerosis, but also induce a process directly injurious to the myocardial metabolism. (Air Pollut. Abstr.)

  19. Carbon Monoxide: An Essential Signalling Molecule

    Science.gov (United States)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  20. Regional and hemispheric influences on temporal variability in baseline carbon monoxide and ozone over the Northeast US

    Science.gov (United States)

    Interannual variability in baseline carbon monoxide (CO) and ozone (O3), defined as mixing ratios under minimal influence of recent and local emissions, was studied for seven rural sites in the Northeast US over 2001–2010. Annual baseline CO exhibited statistically signific...

  1. Satellite observations of tropospheric ammonia and carbon monoxide: Global distributions, regional correlations and comparisons to model simulations

    Science.gov (United States)

    Ammonia (NH3) and carbon monoxide (CO) are primary pollutants emitted to the Earth's atmosphere from common as well as distinct sources associated with anthropogenic and natural activities. The seasonal and global distributions and correlations of NH3 and CO from the Tropospheric...

  2. Exhaled carbon monoxide in asthmatics: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Huang Mao

    2010-04-01

    Full Text Available Abstract Background The non-invasive assessment of airway inflammation is potentially advantageous in asthma management. Exhaled carbon monoxide (eCO measurement is cheap and has been proposed to reflect airway inflammation and oxidative stress but current data are conflicting. The purpose of this meta-analysis is to determine whether eCO is elevated in asthmatics, is regulated by steroid treatment and reflects disease severity and control. Methods A systematic search for English language articles published between 1997 and 2009 was performed using Medline, Embase and Cochrane databases. Observational studies comparing eCO in non-smoking asthmatics and healthy subjects or asthmatics before and after steroid treatment were included. Data were independently extracted by two investigators and analyzed to generate weighted mean differences using either a fixed or random effects meta-analysis depending upon the degree of heterogeneity. Results 18 studies were included in the meta-analysis. The eCO level was significantly higher in asthmatics as compared to healthy subjects and in intermittent asthma as compared to persistent asthma. However, eCO could not distinguish between steroid-treated asthmatics and steroid-free patients nor separate controlled and partly-controlled asthma from uncontrolled asthma in cross-sectional studies. In contrast, eCO was significantly reduced following a course of corticosteroid treatment. Conclusions eCO is elevated in asthmatics but levels only partially reflect disease severity and control. eCO might be a potentially useful non-invasive biomarker of airway inflammation and oxidative stress in nonsmoking asthmatics.

  3. Protective Effect of Edaravone against Carbon Monoxide Induced Apoptosis in Rat Primary Cultured Astrocytes

    Directory of Open Access Journals (Sweden)

    Xiaodan Xu

    2017-01-01

    Full Text Available Objective. To observe the protective effect of edaravone (Eda on astrocytes after prolonged exposure to carbon monoxide (CO and further to investigate the potential mechanisms of Eda against CO-induced apoptosis. Methods. The rat primary cultured astrocytes were cultured in vitro and exposed to 1% CO for 24 h after being cultured with different concentrations of Eda. MTT assay was used to detect the cytotoxicity of CO. Flow cytometry was used to detect the apoptosis rate, membrane potential of mitochondria, and ROS level. The mRNA and protein expressions of Bcl-2, Bax, and caspase-3 were assessed by real-time PCR and Western blotting analysis, respectively. Results. Eda can significantly suppress cytotoxicity of CO, and it can significantly increase membrane potential of mitochondria and Bcl-2 expressions and significantly suppress the apoptosis rate, ROS level, Bax, and caspase-3 expressions. Conclusion. Eda protects against CO-induced apoptosis in rat primary cultured astrocytes through decreasing ROS production and subsequently inhibiting mitochondrial apoptosis pathway.

  4. Atomic hydrogen and diatomic titanium-monoxide molecular spectroscopy in laser-induced plasma

    Science.gov (United States)

    Parigger, Christian G.; Woods, Alexander C.

    2017-03-01

    This article gives a brief review of experimental studies of hydrogen Balmer series emission spectra. Ongoing research aims to evaluate early plasma evolution following optical breakdown in laboratory air. Of interest is as well laser ablation of metallic titanium and characterization of plasma evolution. Emission of titanium monoxide is discussed together with modeling of diatomic spectra to infer temperature. The behavior of titanium particles in plasma draws research interests ranging from the modeling of stellar atmospheres to the enhancement of thin film production via pulsed laser deposition.

  5. Zatrucie tlenkiem węgla – drogi narażenia, obraz kliniczny, metody leczenia = Carbon monoxide poisoning, routes of exposure, clinical manifestation, treatment

    Directory of Open Access Journals (Sweden)

    Magdalena Sowa

    2015-04-01

    owa kluczowe: tlenek węgla, zatrucie, hipoksja.   Abstract   Introduction: Carbon monoxide (CO is a colorless, odorless, non-irritating and toxic gas, undetectable by the sense organs. CO is a product of incomplete combustion of substances containing hydrocarbon products (industrial gas, coal, wood. Carbon monoxide is one of the most common causes of poisoning inhalation in the world. Aim of the study: The aim of this study was to analyze the routes of exposure, clinical manifestation and treatment of carbon monoxide poisoning. Brief overview of the state of knowledge: The toxicity of carbon monoxide is strongly associated with its high affinity for hemoglobin (approximately 200 times greater than the oxygen. The heart and central nervous system (CNS are the most vulnerable to CO. Pathomechanism of action involves binding of carbon monoxide with iron atom in the heme molecule to form a compound called carboxyhemoglobin (COHb. Inhaling carbon monoxide-rich air may cause anoxia. The oxidative metabolic processes are inhibited. Accumulation of acidic metabolites cause the enlargement of the cerebral arteries and consequently hyperemia of the brain. Summary: The amount of carbon monoxide poisoning in Poland is higher than in other European countries. Significant decrease mortality for carbon monoxide poisoning has observed over the last few years. Thousands of patients who lose their health and  their lives, should cause the attention to the effectiveness of preventive measures.   Keywords: carbon monoxide, poisoning, hypoxia.

  6. Metal cluster cation reactions: Carbon monoxide association to Cu + n ions

    Science.gov (United States)

    Leuchtner, R. E.; Harms, A. C.; Castleman, A. W., Jr.

    1990-06-01

    Copper cluster cations (Cu+n,n=1-14) were produced in a laser vaporization/flow tube apparatus and equilibrated to room temperature. The association rate constants of carbon monoxide onto these ions were measured; low-pressure, termolecular behavior was observed for the smaller species while for clusters greater than Cu+7, the longer lifetimes due to the increased number of degrees of freedom leads to pressure independence (>0.3 Torr) of the effective bimolecular rates. Unimolecular decay theory (RRKM) is used to explain the overall trend and when intrinsic surface site reactivity is taken into account, excellent agreement with measured reactivity is obtained.

  7. A Density Functional Theory Study of Doped Tin Monoxide as a Transparent p-type Semiconductor

    KAUST Repository

    Bianchi Granato, Danilo

    2012-05-01

    In the pursuit of enhancing the electronic properties of transparent p-type semiconductors, this work uses density functional theory to study the effects of doping tin monoxide with nitrogen, antimony, yttrium and lanthanum. An overview of the theoretical concepts and a detailed description of the methods employed are given, including a discussion about the correction scheme for charged defects proposed by Freysoldt and others [Freysoldt 2009]. Analysis of the formation energies of the defects points out that nitrogen substitutes an oxygen atom and does not provide charge carriers. On the other hand, antimony, yttrium, and lanthanum substitute a tin atom and donate n-type carriers. Study of the band structure and density of states indicates that yttrium and lanthanum improves the hole mobility. Present results are in good agreement with available experimental works and help to improve the understanding on how to engineer transparent p-type materials with higher hole mobilities.

  8. Lethal carbon monoxide toxicity in a concrete shower unit.

    Science.gov (United States)

    Heath, Karen; Byard, Roger W

    2018-05-23

    A 47-year-old previously-well woman was found dead on the floor of a shower cubicle on a property in rural South Australia. The impression of the attending doctor and police was of collapse due to natural disease. Although there was significant stenosing coronary artery atherosclerosis found at autopsy, cherry pink discoloration of tissues prompted measurement of the blood carboxyhemoglobin level which was found to be 55%. The source of the gas was a poorly-maintained hot water heater that was mounted on the inside wall of the shower. Construction of the shower using an impermeable concrete rain water tank had caused gas accumulation when the water heater malfunctioned. Had lethal carbon monoxide exposure not been identified others using the same shower unit would also have been at risk.

  9. Accidental Carbon Monoxide Poisonings in Adana, Turkey: A 14-year Study

    Directory of Open Access Journals (Sweden)

    Murat Darçın

    2017-03-01

    Full Text Available Aim: Carbon monoxide (CO is often referred to as the “silent killer” because its victims cannot see it, smell it or taste it. CO is responsible for a large percentage of the accidental poisonings and deaths reported throughout the world. CO poisoning therefore is considered a serious global health threat. The aim of the present study was to describe the cases of CO poisoning in a rural areas of Adana, Turkey between 2002 and 2015 based on data collected from incident reports. Methods: The cases of accidental CO poisoning were statistically analyzed. During that period, 74 incidents occurred and 154 people were poisoned by accidental CO poisoning. Results: The results of this analysis indicate that men and adults aged ≥65 years were more likely to die from CO poisoning than others. The number of CO poisoning cases was highest during the heating season. The majority (72% of poisoning resulting in hospitalization with a life-threatening condition or death occurred within the home. Conclusion: CO poisoning is a serious danger. People must be informed about this hazard. By educating risk groups about the dangers of CO poisoning, it is possible to save many lives as well as reduce the health risks.

  10. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    Science.gov (United States)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Etherton, B.P.

    1980-01-01

    The adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts which were examined by a scanning transmission electron microscope (STEM). The metal particle size and number of particles per area of catalyst increased with increasing metal loading. The particles were approx. 10 A. in diameter, cubo-octahedral shaped, and approx. 80-90% disperse. The STEM electron beam caused negligible damage to the samples. Hydrogen adsorption measurements showed that the hydrogen-iridium atom ratio was 1.2:1-1.3:1 and increased with decreasing metal loading. Temperature-programed desorption showed four types of adsorbed hydrogen desorbing at -90/sup 0/C (I), 15/sup 0/C (IV), 115/sup 0/C (II), and 245/sup 0/C (III). Types II and IV desorb from single atom sites and Types I and III from multiple atom sites. Type I is in rapid equilibrium with the gas phase. All desorption processes appear to be first order. Carbon monoxide adsorbed nondissociatively at 25/sup 0/C with approx. 0.7:1 CO/Ir atom ratio. It adsorbed primarily in linear forms at low coverage, but a bridged form appeared at high coverage.

  12. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    Science.gov (United States)

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  13. Electrocardiographic Findings and Serum Troponin I in Carbon Monoxide Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Scott Reza Jafarian Kerman

    2012-03-01

    Full Text Available Carbon monoxide (CO poisoning, though with different sources, is one of the most deadly emergencies in all countries. CO can threaten men's life by several paths especially cardiac complications, which can mimic other cardiac problems such as myocardial infarction. The objective of this study was to determine ECG findings and serum troponin I levels in CO poisoned patients. In this analytical cross-sectional study, 63 CO poisoning patients were consecutively included from hospital's emergency departments. CO content was measured by a CO-oximeter and an electrocardiography was taken first thing on admission. Arterial blood gas (ABG, troponin I and other data was collected afterwards. Data were divided by age groups (adults and children and gender. CO content was significantly higher only in subjects with normal T wave compared to patients with inverted T wave in their initial ECG (P=0.016. No other significant difference was noticed. None of the ABG findings correlated significantly with CO content. Also no significant correlation was found with CO content after stratification by gender and age groups, but pH in children (r=-0.484, P=0.026. CO content was significantly higher in adults (P=0.023, but other ABG data were not significantly different. Only 3 patients had elevated troponin I. Receiver operating characteristic (ROC analysis showed no significant cutoff points in CO content for ECG changes. No significant specific change in electrocardiograms (ECG could contribute carboxyhemoglobin content in carbon monoxide poisoned patients. In addition, no specific difference was found between adults and pediatric subjects' ECGs. All other findings seemed to be accidental.

  14. Measurements of Carbon Dioxide, Carbon Monoxide, and Other Related Tracers at High Spatial and Temporal Resolution in an Urban Environment

    Science.gov (United States)

    Rella, C.; Jacobson, G.

    2012-04-01

    and by acetylene, another tracer that provides complementary information to carbon monoxide as an indicator of combustion. In spring and summer, the combined signal of the urban center and the surrounding biosphere and urban green space is explored. These methods show great promise for quantifying and partitioning carbon dioxide emissions in an urban and mixed urban / ecological setting.

  15. Carbon Monoxide Hydrogenation on Ice Surfaces.

    Science.gov (United States)

    Kuwahata, Kazuaki; Ohno, Kaoru

    2018-03-14

    We have performed density functional calculations to investigate the carbon monoxide hydrogenation reaction (H+CO→HCO), which is important in interstellar clouds. We found that the activation energy of the reaction on amorphous ice is lower than that on crystalline ice. In the course of this study, we demonstrated that it is roughly possible to use the excitation energy of the reactant molecule (CO) in place of the activation energy. This relationship holds also for small water clusters at the CCSD level of calculation and the two-layer-level ONIOM (CCSD : X3LYP) calculation. Generally, since it is computationally demanding to estimate activation energies of chemical reactions in a circumstance of many water molecules, this relationship enables one to determine the activation energy of this reaction on ice surfaces from the knowledge of the excitation energy of CO only. Incorporating quantum-tunneling effects, we discuss the reaction rate on ice surfaces. Our estimate that the reaction rate on amorphous ice is almost twice as large as that on crystalline ice is qualitatively consistent with the experimental evidence reported by Hidaka et al. [Chem. Phys. Lett., 2008, 456, 36.]. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Influence of solvent on the infared spectrum of carbon monoxide adsorbed on platinum electrodes

    OpenAIRE

    Feltovich, Susanne D.

    1993-01-01

    The behavior of adsorbed carbon monoxide on platinum was studied using potential difference infrared spectroscopy. Three solvents and three electrolytes were chosen, and data gathered at both high and low adsorbate coverages. The rate of change of IR peak position with applied potential, the Stark tuning rate, was used as an indicator of the local electric field strength at the interface. It was determined that neither solvated cation size nor bulk dielectric constant accoun...

  17. Subclinical carbon monoxide poisoning in our health area

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, I.G.; Testa, A.F.; Sangrador, C.O.; Garcia, M.T.A.; Berrocal, J.L.S.; Pastor, N.R.; Martin, J.M.; Garcia, L.S.; Garcia, M.C.F.; Maire-Richard, E.G. [Hospital of Virgen Concha, Zamora (Spain)

    2003-08-01

    We present an observation study on the relationship between high levels of carboxyhemoglobin (COHB) and subclinical poisoning by carbon monoxide (CO) in our health area. The study was carried out in February and March 2000 in 228 over 18-year-old patients of both sexes who went to the Emergency Room for various reasons. After an informed consent was conceded, a venous blood sample was obtained in order to determine the level of COHB; later, we collected the anthropometric data, the data relative to the tobacco use, and the data of the type of heating at home. The values limit of the COHB obtained were the following: in non smokers, 1.9%; in 1-10 cigarettes/day smokers, 5.2%; in 11-20 cigarettes/day smokers, 6.9%; in {gt}20 cigarettes/day smokers, 9.6%. A COHB high level was observed in 25% of the patients regardless of the smoking habits, being the coal-dust slack brazier the source of most frequent exposure to CO.

  18. Detection of the J = 6→5 transition of carbon monoxide

    International Nuclear Information System (INIS)

    Goldsmith, P.F.; Erickson, N.R.; Fetterman, H.R.; Clifton, B.J.; Peck, D.D.; Tannenwald, P.E.; Koepf, G.A.; Buhl, D.; McAvoy, N.

    1981-01-01

    The J = 6→5 rotational transition of carbon monoxide has been detected in emission from the KL ''plateau source'' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km s -1 . These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. Our data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approx.180 K

  19. Poisoning by carbon monoxide in the hydrogen exchange reaction between deuterium gas and water preadsorbed on a platinum--alumina catalyst

    International Nuclear Information System (INIS)

    Iida, I.; Tamaru, K.

    1979-01-01

    Poisoning by carbon monoxide in the exchange reaction between deuterium and the water preadsorbed on a platinum--alumina catalyst was studied, by measuring not only the rate of reaction but also its kinetic behavior and the adsorption of reactants on the catalyst surface. The shape of the poisoning curve is closely associated with the kinetic behavior and exhibited an abrupt change on freezing the adsorbed water below 273 0 K. When the rate is proportional to deuterium pressure and independent of the amount of water adsorbed, the exchange rate dropped sharply by carbon monoxide adsorbed of a few percent coverage without any marked changes in the amount and the rate of hydrogen adsorption on the platinum surface. However, at temperatures lower than 273 0 K and at higher deuterium pressures, the rate depends not on the deuterium pressure but on the amount of water adsorbed. The migration of hydrogen in or through the adsorbed water is seemingly sufficiently suppressed by freezing to control the overall reaction rate. In this case, a small amount of adsorption of carbon monoxide did not show any toxicity, but then a steep poisoning started accompanying a change in the kinetic behavior. It was accordingly demonstrated that the mechanism of the reaction may be better understood by studying poisoning and measuring adsorption, overall rate, and kinetic behavior

  20. Comparison of carbon monoxide poisonings originated from coal stove and natural gas and the evaluation of Neutrophil/Lymphocyte ratio

    Directory of Open Access Journals (Sweden)

    Yahya Kemal Günaydın

    2015-09-01

    Full Text Available Objective: The aim of our study is to present the epidemiologic, clinical, laboratory and prognosis differences between the coal stove origin poisoning and natural gas leakages. We also aimed to investigate relationship between the severity of clinical picture, prognosis, complications develop in CO poisoning with neutrophil/lymphocyte ratio (NLR at the initial admission. Methods: All the acute carbon monoxide cases who applied to Ankara Training and Research Hospital Emergency Medicine Clinic between October 2009 and April 2010 were included to this prospective study. CO poisoning diagnosis was made by the history of CO poisoning with carboxyl hemoglobin (COHb concentration is over 10%. 100 patients were included to our study. Results: Of the patients, 55(55% were poisoned from the coal-stove and 45(45% from natural gas leakage. The mean COHb level of the natural gas group was significantly high (p=0.01. The mean value of GCS of the natural gas group was significantly lower (p=0.018. The number of patients with indication for HBO therapy were 17 and 6 in the natural gas group and coal-stove group, respectively, being significantly higher in the natural gas group(p=0.001. There was no statistically significant relationship between the value of NLR and values of COHb, troponin, and GCS (p=0.872, p=0.470, and p=0.896, respectively. Conclusions: Carbon monoxide poisoning from natural gas leakage is more toxic than that from the coal-stove. There is no relationship between NLR at the time of presentation and the severity of clinical findings, prognosis and complications.

  1. Study on radiation degradation of hydroxylamine derivatives. Pt.3: Qualitative and quantitative analyses of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine

    International Nuclear Information System (INIS)

    Wang Jinhua; Bao Borong; Wu Minghong; Sun Xilian

    2004-01-01

    The qualitative and quantitative analysis of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine is performed on a 2 m column packed with 5 Angstrom molecular sieve and equipped with a thermal conductivity detector. The analysis of hydrogen employs argon as a carrier gas, the column temperature is 85 degree C and the detector temperature is 110 degree C; the analysis of carbon monoxide employs hydrogen as a carrier gas, the column temperature is 50 degree C and the detector temperature is 80 degree C. The results show that the volume fraction of hydrogen is increased with the increase of dose, but has little relationship with the concentration of N,N-diethyl hydroxylamine. Carbon monoxide is only produced when the absorption dose is very high and the volume fraction is very low

  2. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    Science.gov (United States)

    At some level, carboxyhemoglobin (RbCO) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in normal and ischemic heart patients. At high RbCO levels in normal subjects, brain function is also affected and behavioral performance is impaired. These are fin...

  3. Ferromagnetic semiconductor-metal transition in heterostructures of europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias; Kroha, Johann [Physikalisches Institut der Universitaet Bonn (Germany)

    2012-07-01

    Experiments on thin films of electron doped europium monoxide show a simultaneous ferromagnetic semiconductor-metal transition which goes along with a huge drop in resistivity over several orders of magnitude. Therefore, this material is a very promising candidate for spintronics applications. We have developed a theory which correctly predicts the simultaneous phase transition in thin films of electron doped EuO and the increase of the Curie temperature T{sub C} with doping concentration. The origin of the increased T{sub C} lies in the enhanced RKKY interaction between the localized 4f moments of the Eu atoms. Therefore, the phase transition is controlled by the population of the conduction band. We investigate the influence of film thickness and interface effects on the population of the conduction band and on the magnetic and electronic properties of the EuO film.

  4. Computation of diatomic molecular spectra for selected transitions of aluminum monoxide, cyanide, diatomic carbon, and titanium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Parigger, Christian G., E-mail: cparigge@tennessee.edu [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Woods, Alexander C.; Surmick, David M.; Gautam, Ghaneshwar; Witte, Michael J. [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Hornkohl, James O. [Hornkohl Consulting, Tullahoma, TN 37388 (United States)

    2015-05-01

    Laser ablation studies with laser-induced breakdown spectroscopy (LIBS) typically emphasize atomic species yet fingerprints from molecular species can occur subsequently or concurrently. In this work, selected molecular transitions of aluminum monixide (AlO), diatomic carbon (C{sub 2}), cyanide (CN), and titanium monoxide (TiO) are accurately computed. Line strength tables are used to describe the radiative transitions of diatomic molecules primarily in the visible, optical region. Details are elaborated of the computational procedure that allows one to utilize diatomic spectra as a predictive and as a diagnostic tool. In order to create a computed spectrum, the procedure requires information regarding the temperature of the diatomic transitions along with other input such as the spectral resolution. When combined with a fitting algorithm to optimize such parameters, this procedure is used to infer information from an experimentally obtained spectrum. Furthermore, the programs and data files are provided for LIBS investigations that also reveal AlO, C{sub 2}, CN, and TiO diatomic spectra. - Highlights: • We present a program for fitting of molecular spectra. • This includes data base for AlO, C{sub 2}, CN, and TiO. • We discuss the details of the program including fitting. • We show computed examples and reference current work.

  5. 1H MR spectroscopy of gray and white matter in carbon monoxide poisoning

    DEFF Research Database (Denmark)

    Kondziella, D.; Danielsen, E.R.; Hansen, K.

    2009-01-01

    Carbon monoxide (CO) intoxication leads to acute and chronic neurological deficits, but little is known about the specific noxious mechanisms. (1)H magnetic resonance spectroscopy (MRS) may allow insight into the pathophysiology of CO poisoning by monitoring neurochemical disturbances, yet only......, magnetic resonance imaging (MRI) and neuropsychological testing. Five patients suffered from acute high-dose CO intoxication and were in coma for 1-6 days. In these patients, MRI revealed hyperintensities of the white matter and globus pallidus and also showed increased choline (Cho) and decreased N...

  6. Unintentional carbon monoxide poisoning hospitalization and emergency department counts and rates by county, year, and fire-relatedness among California residents,2000-2007

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of unintentional carbon monoxide poisoning (CO) inpatient hospitalizations and emergency...

  7. Investigation of four carbon monoxide isotopomers in natural abundance by laser-induced fluorescence in a supersonic jet

    CSIR Research Space (South Africa)

    Du Plessis, A

    2007-01-01

    Full Text Available The four carbon monoxide (CO) isotopomers 12C16O, 13C16O, 12C18O and 12C17O have been detected simultaneously in a CO gas sample of natural isotopic abundance by measuring rovibronic excitation spectra of six vibronic bands in the Fourth Positive...

  8. Copolymerization of carbon monoxide and styrene catalyzed by resin-supported palladium polymer

    Directory of Open Access Journals (Sweden)

    2007-02-01

    Full Text Available Polyketone was prepared by the copolymerization of carbon monoxide (CO and styrene (ST catalyzed by o-phenylenediamine resin-supported palladium acetate. Effects of each catalytic system component such as 2,2’-bipyridine, 1,4-quinone and p-toluene-sulphonate on the copolymerization were investigated. The resin-supported catalyst and the copolymerization product were characterized by infrared spectroscopy (IR, differential scanning calorimetry (DSC, thermogravimetry (TG, X-ray photoelectron spectroscopy (XPS, Scanning Electron Microscopy (SEM. Results indicated that the resin-supported catalyst has excellent catalytic property. Furthermore, partial catalytic activity was maintained after the catalyst was used for five times.

  9. Magnetic Resonance Imaging Findings in Chronic Carbon Monoxide Intoxication

    Energy Technology Data Exchange (ETDEWEB)

    Durak, A. C.; Coskun, A.; Yikilmaz, A.; Erdogan, F.; Mavili, E.; Guven, M. [Hospital of Erciyes Univ., Kayseri (Turkey). Dept. of Radiology

    2005-05-01

    Purpose: To define the cranial magnetic resonance imaging (MRI) features of the chronic stage of carbon monoxide (CO) poisoning in patients with and without neuropsychiatric sequelae. Material and Methods: Eight patients who had neither symptoms nor neurological sequelae and eight patients with neuropsychiatric sequelae were included in the study. Patients aged between 9 to 57 (mean 32.2 years). All patients had been comatose at initial admittance and awoke after normobaric 100% oxygen therapy within 1-7 days. In this study, the patients were being examined with routine cranial MRI between 1 and 10 years (mean 3.4 years) after exposure to CO. Results: The most common finding was bilateral symmetric hyperintensity of the white matter, which was more significant in the centrum semiovale, with relative sparing of the temporal lobes and anterior parts of the frontal lobes on T2-weighted and FLAIR images in all patients. Cerebral cortical atrophy was seen in 10 patients; mild atrophy of cerebellar hemispheres in 8; and vermian atrophy in 11. Corpus callosum was atrophic in one patient. Bilateral globus pallidus lesions were seen in three patients. The lesions were hypointense on T1-weighted images and hyperintense on T2-weighted and FLAIR images. Conclusion: Patients with severe CO intoxication may develop persistent cerebral changes independently of their neuropsychiatric findings in the chronic stage. They may present with characteristic MRI findings as described here, even if asymptomatic. The history of CO exposure is therefore helpful for recognizing and interpreting the MRI findings of chronic stage CO intoxication.

  10. Selective carbon monoxide oxidation over Ag-based composite oxides

    Energy Technology Data Exchange (ETDEWEB)

    Guldur, C. [Gazi University, Ankara (Turkey). Chemical Engineering Department; Balikci, F. [Gazi University, Ankara (Turkey). Institute of Science and Technology, Environmental Science Department

    2002-02-01

    We report our results of the synthesis of 1 : 1 molar ratio of the silver cobalt and silver manganese composite oxide catalysts to remove carbon monoxide from hydrogen-rich fuels by the catalytic oxidation reaction. Catalysts were synthesized by the co-precipitation method. XRD, BET, TGA, catalytic activity and catalyst deactivation studies were used to identify active catalysts. Both CO oxidation and selective CO oxidation were carried out in a microreactor using a reaction gas mixture of 1 vol% CO in air and another gas mixture was prepared by mixing 1 vol% CO, 2 vol% O{sub 2}, 84 vol% H{sub 2}, the balance being He. 15 vol% CO{sub 2} was added to the reactant gas mixture in order to determine the effect of CO{sub 2}, reaction gases were passed through the humidifier to determine the effect of the water vapor on the oxidation reaction. It was demonstrated that metal oxide base was decomposed to the metallic phase and surface areas of the catalysts were decreased when the calcination temperature increased from 200{sup o}C to 500{sup o}C. Ag/Co composite oxide catalyst calcined at 200{sup o}C gave good activity at low temperatures and 90% of CO conversion at 180{sup o}C was obtained for the selective CO oxidation reaction. The addition of the impurities (CO{sub 2} or H{sub 2}O) decreased the activity of catalyst for selective CO oxidation in order to get highly rich hydrogen fuels. (author)

  11. Unusual way of suicide by carbon monoxide. Case Report.

    Science.gov (United States)

    Zelený, Michal; Pivnička, Jan; Šindler, Martin; Kukleta, Pavel

    2015-01-01

    Authors discuss the case of a suicide of a 29-year-old man caused by carbon monoxide (CO) intoxication. What the authors found interesting was the unusual way of committing suicide that required good technical skills and expert knowledge. The level of carboxyhemoglobin (COHb) in the blood of the deceased man was routinely determined by the modified method by Blackmoore (1970), using gas chromatography/thermal conductivity detection. The level of saturation of the hemoglobin by CO in the collected blood sample is determined relatively to the same sample saturated to 100%. In the blood sample of the deceased man the lethal concentration of COHb of 76.5% was determined. Within the following examinations the blood alcohol concentration of 0.05 g.kg(-1) was determined. Further analysis revealed traces of sertraline, its metabolite N-desmethylsertraline, omeprazole and caffeine in the liver tissue, traces of N-desmethylsertraline, ibuprofen and caffeine in urine sample, and only traces of caffeine in the stomach content and blood samples were proved. To commit suicide the man used a sophisticated double container-system equipped with a timer for controlled generation of CO based on the chemical reaction of concentrated sulphuric acid and formic acid. The used timer was set by an electromechanical timer switch that triggered the fatal reaction of the acids while the man was sleeping. The authors discuss an unusual case of suicide by CO intoxication rarely seen in the area of forensic medicine and toxicology that is specific due to its sophisticated way of execution.

  12. Nanometer-scale discernment of field emission from tungsten surface with single carbon monoxide molecule

    Science.gov (United States)

    Matsunaga, Soichiro; Suwa, Yuji; Katagiri, Souichi

    2017-12-01

    Unusual quantized beam fluctuations were found in the emission current from a cold-field emitter (CFE) operating in an extremely high vacuum of 10-10 Pa. To clarify the microscopic mechanism behind these fluctuations, we developed a new calculation method to evaluate the field emission from a heterogeneous surface under a strong electric field of 4 × 109 V/m by using the local potential distribution obtained by a first-principles calculation, instead of by using the work function. As a result of the first-principles calculations of a single molecule adsorbed on a tungsten surface, we found that dissociative adsorption of a carbon monoxide (CO) molecule enhances the emission current by changing the potential barrier in the area surrounding the C and O adatoms when these two atoms are placed at their most stable positions. It is also found that the migration of the O atom from the most stable position reduces the emission current. These types of enhancement and reduction of the emission current quantitatively explain the observed quantized fluctuations of the CFE emission current.

  13. Simulation and optimization of stable isotope 13C separation by carbon monoxide cryogenic distillation

    International Nuclear Information System (INIS)

    Li Hulin; Ju Yonglin; Li Liangjun; Xu Dagang

    2009-01-01

    A stable isotope 13 C separation column was set up by carbon monoxide (CO) cryogenic distillation. Diameter of the column is 45 mm, packing height is 17.5 m, of which enriching section is 15 m and stripping section is 2.5 m. Firstly, computer simulation results were validated by test results. Secondly, tests were replaced by computer simulations in order to obtain the optimal operation conditions in the experimental setup. Comprehensive factors of column pressure, feeding velocity, reflux ratio, withdrawing velocity, and boiling power impacts on the products were studied. Then optimization design of the experimental device was achieved through computer simulations combined with uniform experimental design. The final results show that the optimal operation conditions in the built column are as followings: boiling power, 250 W; column pressure, 54 kPa; reflux ratio, 84. The conclusion is that the method of combination of computer simulation and experimental design could be applied to 13 C industrial design and could be popularized in traditional distillation process to realize optimization design. (authors)

  14. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    Science.gov (United States)

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  15. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide 5 degree by 5 degree data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS OverviewThe MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights on...

  16. The study on catalytic performance of CuO/CexZr1-xO2 catalyst in carbon monoxide oxidation

    Directory of Open Access Journals (Sweden)

    Huang Jinhua

    2017-12-01

    Full Text Available A series of CuO/CexZr1-xO2 samples were prepared by incipient-wetness impregnation method with CexZr1-xO2 used as the catalyst carrier which was synthesized by co-precipitation method.The influences of the mass ratio of CeO2:ZrO2 and CuO loading were investigated using catalytic activity test,XRD,BET,H2-TPR,and CO-TPR techniques.The results revealed that with a CeO2:ZrO2 mass ratio of 4:1 and 10% CuO loading,10%CuO/Ce0.815Zr0.185O2 catalyst showed a larger surface area and pore volume,a higher dispersity of CuO particles,better reduction property and CO oxidation property.Thus,10% CuO/Ce0.815Zr0.185O2 catalyst exhibited a high catalytic activity in the carbon monoxide oxidation with 100% CO conversion at the temperature as low as 80℃ under atmospheric pressure.

  17. On the feasibility of monitoring carbon monoxide in the lower troposphere from a constellation of Northern Hemisphere geostationary satellites. (Part 1)

    Science.gov (United States)

    Barré, Jérôme; Edwards, David; Worden, Helen; Da Silva, Arlindo; Lahoz, William

    2015-07-01

    By the end of the current decade, there are plans to deploy several geostationary Earth orbit (GEO) satellite missions for atmospheric composition over North America, East Asia and Europe with additional missions proposed. Together, these present the possibility of a constellation of geostationary platforms to achieve continuous time-resolved high-density observations over continental domains for mapping pollutant sources and variability at diurnal and local scales. In this paper, we use a novel approach to sample a very high global resolution model (GEOS-5 at 7 km horizontal resolution) to produce a dataset of synthetic carbon monoxide pollution observations representative of those potentially obtainable from a GEO satellite constellation with predicted measurement sensitivities based on current remote sensing capabilities. Part 1 of this study focuses on the production of simulated synthetic measurements for air quality OSSEs (Observing System Simulation Experiments). We simulate carbon monoxide nadir retrievals using a technique that provides realistic measurements with very low computational cost. We discuss the sampling methodology: the projection of footprints and areas of regard for geostationary geometries over each of the North America, East Asia and Europe regions; the regression method to simulate measurement sensitivity; and the measurement error simulation. A detailed analysis of the simulated observation sensitivity is performed, and limitations of the method are discussed. We also describe impacts from clouds, showing that the efficiency of an instrument making atmospheric composition measurements on a geostationary platform is dependent on the dominant weather regime over a given region and the pixel size resolution. These results demonstrate the viability of the ;instrument simulator; step for an OSSE to assess the performance of a constellation of geostationary satellites for air quality measurements. We describe the OSSE results in a follow up

  18. Photodissociation of the carbon monoxide dication in the {sup 3}Σ{sup −} manifold: Quantum control simulation towards the C{sup 2+} + O channel

    Energy Technology Data Exchange (ETDEWEB)

    Vranckx, S. [Service de Chimie Quantique et Photophysique, Université Libre de Bruxelles (ULB), CP 160/09, B-1050 Brussels (Belgium); Laboratoire de Chimie Physique (UMR 8000), Université Paris-Sud, Orsay 91405 (France); Loreau, J.; Vaeck, N. [Service de Chimie Quantique et Photophysique, Université Libre de Bruxelles (ULB), CP 160/09, B-1050 Brussels (Belgium); Meier, C. [Laboratoire Collisions Agrégats Réactivité, UMR 5589, IRSAMC, Université Toulouse III Paul Sabatier, Bât. 3R1b4, Toulouse (France); Desouter-Lecomte, M., E-mail: michele.desouter-lecomte@u-psud.fr [Laboratoire de Chimie Physique (UMR 8000), Univ. Paris Sud, Université Paris-Saclay, Orsay 91405 (France); Département de Chimie, B6c Université de Liège, Sart Tilman, 4000 Liège (Belgium)

    2015-10-28

    The photodissociation and laser assisted dissociation of the carbon monoxide dication X{sup 3}Π CO{sup 2+} into the {sup 3}Σ{sup −} states are investigated. Ab initio electronic structure calculations of the adiabatic potential energy curves, radial nonadiabatic couplings, and dipole moments for the X {sup 3}Π state are performed for 13 excited {sup 3}Σ{sup −} states of CO{sup 2+}. The photodissociation cross section, calculated by time-dependent methods, shows that the C{sup +} + O{sup +} channels dominate the process in the studied energy range. The carbon monoxide dication CO{sup 2+} is an interesting candidate for control because it can be produced in a single, long lived, v = 0 vibrational state due to the instability of all the other excited vibrational states of the ground {sup 3}Π electronic state. In a spectral range of about 25 eV, perpendicular transition dipoles couple this {sup 3}Π state to a manifold of {sup 3}Σ{sup −} excited states leading to numerous C{sup +} + O{sup +} channels and a single C{sup 2+} + O channel. This unique channel is used as target for control calculations using local control theory. We illustrate the efficiency of this method in order to find a tailored electric field driving the photodissociation in a manifold of strongly interacting electronic states. The selected local pulses are then concatenated in a sequence inspired by the “laser distillation” strategy. Finally, the local pulse is compared with optimal control theory.

  19. Carbon monoxide measurements at Mace Head, Ireland

    Science.gov (United States)

    Doddridge, Bruce G.; Dickerson, Russell R.; Spain, T. Gerard; Oltmans, Samuel J.; Novelli, Paul C.

    1994-01-01

    The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

  20. CO2 Reduction Catalyzed by Nitrogenase: Pathways to Formate, Carbon Monoxide, and Methane

    OpenAIRE

    Khadka, Nimesh; Dean, Dennis R.; Smith, Dayle; Hoffman, Brian M.; Raugei, Simone; Seefeldt, Lance C.

    2016-01-01

    The reduction of N2 to NH3 by Mo-dependent nitrogenase at its active-site metal cluster FeMo-cofactor utilizes reductive elimination (re) of Fe-bound hydrides with obligatory loss of H2 to activate the enzyme for binding/reduction of N2. Earlier work showed that wild type nitrogenase and a nitrogenase having amino acid substitutions in the MoFe protein near FeMo-cofactor can catalytically reduce CO2 by 2 or 8 electrons/protons to carbon monoxide (CO) and methane (CH4) at low rates. Here, it i...

  1. Far-ultraviolet fluorescence of carbon monoxide in the red giant Arcturus

    International Nuclear Information System (INIS)

    Ayres, T.R.; Moos, H.W.; Linsky, J.L.

    1981-01-01

    We present evidence that many of the weak features observed with the International Ultraviolet Explorer (IUE) in the far-ultraviolet (1150--2000 A) spectrum of the archetype red giant Arcturus (K2 III) are A--X fourth positive bands of carbon monoxide excited by chromospheric emissions of O I, C I, and H I. The appearance of fluorescent CO bands near the wavelengths of commonly used indicators of high-temperature (T>2 x 10 4 K) plasma, such as C II lambda1335 and C IV lambda1548, introduces a serious ambiguity in diagnosing the presence of hot material in the outer atmospheres of the cool giants by means of low-dispersion IUE spectra

  2. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  3. Recent changes in carbon dioxide, carbon monoxide and methane and the implications for global climate change

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Conway, T.J.; Dlugokencky, E.J.; Tans, P.P. [National Oceanic and Atmospheric Administration, Boulder, CO (United States). Climate Monitoring and Diagnostics Lab.

    1995-01-01

    The article reviews figures for published data on recent changes of atmospheric levels of carbon dioxide, carbon monoxide and methane in terms of their sources and sinks. The largest source of CO{sub 2} is the combustion of fossil fuels, followed by emissions from deforestation and the oxidation of CO to CO{sub 2}. Carbon monoxide has an indirect influence on the earth`s radiative balance, as if levels of CO increase, levels of OH radicals decline which affects removal of other gases oxidised by this radical, notably CH{sub 4}. Major sources of CO are fossil fuel combustion, emissions from biomass, and oxidation of atmospheric CH{sub 4} and other non-methane hydrocarbons. The latest measurements suggest the depressed growth rates of CO{sub 2}, CO and CH{sub 4} have began to recover. Reasons for this are suggested. Future monitoring of atmospheric species in laboratories around the world, coupled with information on the isotopic signature of the trace gases, will improve our understanding of possible causes for trends in these gases. This will be invaluable in making policy decisions regarding future climate change. 34 refs., 4 figs.

  4. Carbon monoxide from neighbouring restaurants: the need for an integrated multi-agency response.

    Science.gov (United States)

    Keshishian, C; Sandle, H; Meltzer, M; Young, Y; Ward, R; Balasegaram, S

    2012-12-01

    Carbon monoxide (CO) is a colourless, odourless toxic gas produced during incomplete combustion of carbon-based fuels. Most CO incidents reported to the UK Health Protection Agency (HPA) are due to faulty gas appliances, and legislation exists to ensure gas appliances are properly installed. We present three CO poisoning incidents of unusual origin reported to the HPA. In each, residents living above restaurants were poisoned after workers left charcoal smouldering overnight in specialist or traditional ovens whilst ventilation systems were turned off. This led to production of CO, which travelled through floorboards and built up to dangerous concentrations in the flats. Working with local authorities, these incidents were investigated and resolved, and work was conducted to prevent further occurrences. The novel nature of these CO incidents led to delays in recognition and subsequent remedial action. Although previously undescribed, it is likely that due to the number of residences built above restaurants and the rising popularity of traditional cooking methods, similar incidents may be occurring and could increase in frequency. Multi-agency response and reporting mechanisms could be strengthened. Awareness raising in professional groups and the public on the importance of correct ventilation of such appliances is vital.

  5. Retinal venous blood carbon monoxide response to bright light in male pigs: A preliminary study.

    Science.gov (United States)

    Oren, Dan A; Duda, Magdalena; Kozioł, Katarzyna; Romerowicz-Misielak, Maria; Koziorowska, Anna; Sołek, Przemysław; Nowak, Sławomir; Kulpa, Magdalena; Koziorowski, Marek

    2017-03-01

    The physical mechanism by which light is absorbed in the eye and has antidepressant and energizing effects in Seasonal Affective Disorder and other forms of psychiatric major depression is of scientific interest. This study was designed to explore one specific aspect of a proposed humoral phototransduction mechanism, namely that carbon monoxide (CO) levels increase in retinal venous blood in response to bright light. Eleven mature male pigs approximately six months of age were kept for 7days in darkness and fasted for 12h prior to surgery. Following mild sedation, anesthesia was induced. Silastic catheters were inserted into the dorsal nasal vein through the angular vein of the eye to reach the ophthalmic sinus, from which venous blood outflowing from the eye area was collected. The animals were exposed to 5000lx of fluorescent-generated white light. CO levels in the blood were analyzed by gas chromatography before and after 80min of light exposure. At baseline, mean CO levels in the retinal venous blood were 0.43±0.05(SE)nmol/ml. After bright light, mean CO levels increased to 0.54±0.06nmol/ml (two-tailed t-test plight exposure raises carbon monoxide levels in ophthalmic venous blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. [Etiology of combined inhalational hydrocyanic acid and carbon monoxide poisoning].

    Science.gov (United States)

    Sigrist, T; Dirnhofer, R

    1979-01-01

    A young man was found dead in a kitchen, that was partly burnt. Autopsy revealed, as cause of death, a combined intoxication following inhalation of carbon monoxide and hydrocyanic acid. Own investigations on the pyrolysis of pieces of furniture found in the kitchen (plastic plates containing melamine and plates containing formaldehyde) showed, that hydrocyanic acid was liberated through combustion of such substances and inhaled by the victim. The poisoning picture is discussed, and discussion includes especially considerations on the peculiar sensitivity of the brain toward the action of hydrocyanic acid and the relative insensitivity of the heart muscle. It is thought that the cause of such sensitivity difference lies in the physiological differences of the intracellular energy production. Finally the dangers of combustion gases developing from burning plastic materials are reemphasized.

  7. Review: hemodynamic response to carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Penney, D.G.

    1988-04-01

    Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. Augmented cardiac output usually observed with moderate COHb may be compromised in more sever poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.

  8. The effect of modified atmosphere packaging with carbon monoxide on the storage quality of master-packaged fresh pork

    NARCIS (Netherlands)

    Wilkinson, B.H.P.; Janz, J.A.M.; Morel, P.C.H.; Purchas, R.W.; Hendriks, W.H.

    2006-01-01

    Modified atmosphere packaging with carbon dioxide is effective for prolonging shelf-life of fresh meat. Addition of carbon monoxide to the system provides the advantage of enhancing meat colour. The study objective was to determine the effect of CO2-MAP + 0.4% CO, vs. 100% CO2-MAP, on the

  9. Kinetics of carbon monoxide oxidation over modified supported CuO catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Loc, Luu Cam; Tri, Nguyen; Cuong, Hoang Tien; Thoang, Ho Si [Vietnam Academy of Science and Technology (VAST), Ho Chi Minh City (Viet Nam). Inst. of Chemical Technology; Agafonov, Yu.A.; Gaidai, N.A.; Lapidus, A.L. [Russian Academy of Sciences, Moscow (Russian Federation). N.D. Zelinsky Institute of Organic Chemistry

    2013-11-01

    The following supported on {gamma}-Al{sub 2}O{sub 3} catalysts: 10(wt.)%CuO (CuAl), 10%CuO+10%Cr{sub 2}O{sub 3} (CuCrAl) and 10%CuO+20%CeO{sub 2} (CuCeAl) were under the investigation. Physico-chemical characteristics of the catalysts were determined by the methods of BET, X-ray Diffraction (XRD), and Temperature-Programmed Reduction (TPR). A strong interaction of copper with support in CuAl resulted in the formation of low active copper aluminates. The bi-oxide CuCrAl was more active than CuAl owing to the formation of high catalytically active spinel CuCr{sub 2}O{sub 4}. The fact of very high activity of the sample CuCeAl can be explained by the presence of the catalytically active form of CuO-CeO{sub 2}-Al{sub 2}O{sub 3}. The kinetics of CO total oxidation was studied in a gradientless flow-circulating system at the temperature range between 200 C and 270 C. The values of initial partial pressures of carbon monoxide (P{sup o}{sub CO}), oxygen (P{sup o}{sub O2}), and specially added carbon dioxide (P{sup o}{sub CO{sub 2}}) were varied in ranges (hPa): 10 / 45; 33 / 100, and 0 / 30, respectively. (orig.)

  10. Multiple Victims of Carbon Monoxide Poisoning in the Aftermath of a Wildfire: A Case Series

    Directory of Open Access Journals (Sweden)

    Luís Ramos dos Santos

    2018-03-01

    Conclusion: Use of hyperbaric oxygen appears to have reduced the incidence of the syndrome. This seems to be the first Portuguese series reporting use of hyperbaric oxygen in carbon monoxide poisoning due to wildfires. The authors intend to alert to the importance of referral of these patients because the indications and benefits of this treatment are well documented. This is especially important given the ever-growing issue of wildfires in Portugal.

  11. Carbon Monoxide Distribution over Peninsular Malaysia from the Atmospheric Infrared Sounder (AIRS)

    Science.gov (United States)

    Rajab, Jaso M.; MatJafri, M. Z.; Lim, H. S.; Abdullah, K.

    2009-07-01

    The Atmospheric Infrared Sounder (AIRS) onboard NASA's Aqua satellite. It daily coverage of ˜70% of the planet represents a significant evolutionary advance in satellite traces gas remote sensing. AIRS, the part of a large international investment to upgrade the operational meteorological satellite systems, is first of the new generation of meteorological advanced sounders for operational and research use, Providing New Insights into Weather and Climate for the 21st Century. Carbon monoxide (CO) is a ubiquitous, an indoor and outdoor air pollutant, is not a significant greenhouse gas as it absorbs little infrared radiation from the Earth. However, it does have an influence on oxidization in the atmosphere through interaction with hydroxyl radicals (OH), which also react with methane, halocarbons and tropospheric ozone. It produced by the incomplete combustion of fossil fuels and biomass burning, and that it has a role as a smog. The aim of this investigation is to study the (CO) carbon monoxide distribution over Peninsular Malaysia. The land use map of the Peninsular Malaysia was conducted by using CO total column amount, obtained from AIRS data, the map & data was processed and analyzed by using Photoshop & SigmaPlot 11.0 programs and compared for timing of various (day time) (28 August 2005 & 29 August 2007) for both direct comparison and the comparison using the same a priori profile, the CO concentrations in 28/8/2005 higher. The CO maps were generated using Kriging Interpolation technique. This interpolation technique produced high correlation coefficient, R2 and low root mean square error, RMS for CO. This study provided useful information for influence change of CO concentration on varies temperature.

  12. Using ANN and EPR models to predict carbon monoxide concentrations in urban area of Tabriz

    Directory of Open Access Journals (Sweden)

    Mohammad Shakerkhatibi

    2015-09-01

    Full Text Available Background: Forecasting of air pollutants has become a popular topic of environmental research today. For this purpose, the artificial neural network (AAN technique is widely used as a reliable method for forecasting air pollutants in urban areas. On the other hand, the evolutionary polynomial regression (EPR model has recently been used as a forecasting tool in some environmental issues. In this research, we compared the ability of these models to forecast carbon monoxide (CO concentrations in the urban area of Tabriz city. Methods: The dataset of CO concentrations measured at the fixed stations operated by the East Azerbaijan Environmental Office along with meteorological data obtained from the East Azerbaijan Meteorological Bureau from March 2007 to March 2013, were used as input for the ANN and EPR models. Results: Based on the results, the performance of ANN is more reliable in comparison with EPR. Using the ANN model, the correlation coefficient values at all monitoring stations were calculated above 0.85. Conversely, the R2 values for these stations were obtained <0.41 using the EPR model. Conclusion: The EPR model could not overcome the nonlinearities of input data. However, the ANN model displayed more accurate results compared to the EPR. Hence, the ANN models are robust tools for predicting air pollutant concentrations.

  13. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    Science.gov (United States)

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  14. The immunomodulatory role of carbon monoxide during transplantation

    Directory of Open Access Journals (Sweden)

    Amano Mariane

    2013-01-01

    Full Text Available Abstract The number of organ and tissue transplants has increased worldwide in recent decades. However, graft rejection, infections due to the use of immunosuppressive drugs and a shortage of graft donors remain major concerns. Carbon monoxide (CO had long been regarded solely as a poisonous gas. Ultimately, physiological studies unveiled the endogenous production of CO, particularly by the heme oxygenase (HO-1 enzyme, recognizing CO as a beneficial gas when used at therapeutic doses. The protective properties of CO led researchers to develop uses for it, resulting in devices and molecules that can deliver CO in vitro and in vivo. The resulting interest in clinical investigations was immediate. Studies regarding the CO/HO-1 modulation of immune responses and their effects on various immune disorders gave rise to transplantation research, where CO was shown to be essential in the protection against organ rejection in animal models. This review provides a perspective of how CO modulates the immune system to improve transplantation and suggests its use as a therapy in the field.

  15. Brain CT scan in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    We, En-Huei

    1986-01-01

    The brain CT findings in 19 patients with acute carbon monoxide poisoning was analysed and the emphasis was placed on the relationship between CT findings and prognosis. Five had a normal manifestation in CT ; eight had the findings of ovoid or patchy low density area in globus pallidus, bilateral or unlateral, during the second day to fifth week after poisoning, and the low density areas were decreasing and blurring in edge in follow up and at last disappeared during 3 - 14 weeks in three cases of them ; nine showed the appearance of diffuse low density of white matter and of globus pallidus in some of them ; two had an appearance of brain atrophy. The pathology of CT findings mentioned above may be brain edema, necrosis, malacia and degeneration in gray matter and globus pallidus. The result suggested the cases with normal CT manifestation, cerebral edema and decreasing and disappearing low density area had a good prognosis, in contrary, the cases with persistant low density in globus pallidus had a poorer prognosis. (author)

  16. General circulation model study of atmospheric carbon monoxide

    International Nuclear Information System (INIS)

    Pinto, J.P.; Yung, Y.L.; Rind, D.; Russell, G.L.; Lerner, J.A.; Hansen, J.E.; Hameed, S.

    1983-01-01

    The carbon monoxide cycle is studied by incorporating the known and hypothetical sources and sinks in a tracer model that uses the winds generated by a general circulation model. Photochemical production and loss terms, which depend on OH radical concentrations, are calculated in an interactive fashion. The computed global distribution and seasonal variations of CO are compared with observations to obtain constraints on the distribution and magnitude of the sources and sinks of CO, and on the tropospheric abundance of OH. The simplest model that accounts for available observations requires a low latitude plant source of about 1.3 x 10 15 g yr -1 , in addition to sources from incomplete combustion of fossil fuels and oxidation of methane. The globally averaged OH concentration calculated in the model is 7 x 10 5 cm -3 . Models that calculate globally averaged OH concentrations much lower than our nominal value are not consistent with the observed variability of CO. Such models are also inconsistent with measurements of CO isotopic abundances, which imply the existence of plant sources

  17. Nitric oxide and carbon monoxide diffusing capacity after a 1-h oxygen dive to 9 m of sea water

    NARCIS (Netherlands)

    van Ooij, P. J. A. M.; van Hulst, R. A.; Houtkooper, A.; Sterk, P. J.

    2014-01-01

    To prevent extensive pulmonary lesions in submerged oxygen divers lung function like the forced vital capacity (FVC) or the diffusing capacity for carbon monoxide (DL,co) are used to monitor pulmonary oxygen toxicity (POT). As the diffusing capacity for nitric oxide (DL,no) measures more accurately

  18. THE ROLE OF CARBON MONOXIDE IN THE REGULATION OF ELECTRICAL AND CONTRACTILE PROPERTIES OF SMOOTH MUSCLE CELLS OF THE GUINEA PIG URETER

    Directory of Open Access Journals (Sweden)

    I. V. Kovalyov

    2014-01-01

    Full Text Available Carbon monoxide CO, as well as nitric oxide and hydrogen sulfide, make up the family of labile biological mediators termed gasotransmitters. We hypothesized that CO may be involved in the mechanisms of regulation electrical and contractile properties of smooth muscles.The effects of carbon monoxide donor CORM II (tricarbonyldichlororuthenium(II-dimer on the electrical and contractile activities of smooth muscles of the guinea pig ureter were studied by the method of the double sucrose bridge. This method allows to register simultaneously the parameters of the action potential (AP and the contraction of smooth muscle cells (SMCs, caused by an electrical stimulus.CORM II in a concentration of 10 mmol has reduced the amplitude of contractions SMCs to (86.5 ± 9.7% (n = 6, p < 0.05, the amplitude of the AP to (88.9 ± 4.2% (n = 6, p < 0.05 and the duration of the plateau of the AP to (91.7 ± 6.0% (n = 6, p < 0.05. On the background of the action of biologically active substances (phenylephrine, 10 µmol or histamine, 10 µmol, these effects of CORM II amplified. The inhibitory action of СORM II on the parameters of the contractile and electrical activities of the smooth muscles of guinea pig ureter has been decreased by blocking potassium channels in membrane of SMCs by tetraethylammonium chloride (TEA оr inhibition of soluble guanylate cyclase (ODQ [1H-[1,2,4]-oxadiazolo[4,3-a]quinoxalin-l-one]. On the background of TEA (5 mmol, a donor of CO (10 mmol caused a reduction the amplitude of contraction SMCs to (87.0 ± 10.8% (n = 6, p < 0.05, the amplitude of the AP to (91.7 ± 6.4% (n = 6, p < 0.05 and the duration of the plateau of the AP to (93.4 ± 7.5% (n = 6, p < 0.05. After the pretreatment of ODQ (1 µmol adding CORM II (10 mmol in solution has resulted to augment of the amplitude of contraction ureteral smooth muscle strips to (90.9 ± 4.2% (n = 6, p < 0.05, the amplitude of the AP to (97.2 ± 10.3% (n = 6, p < 0.05 and the duration of the

  19. The effect of carbon monoxide on planetary haze formation

    Energy Technology Data Exchange (ETDEWEB)

    Hörst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  20. Bio-Inspired Carbon Monoxide Sensors with Voltage-Activated Sensitivity

    KAUST Repository

    Savagatrup, Suchol

    2017-09-27

    Carbon monoxide (CO) outcompetes oxygen when binding to the iron center of hemeproteins, leading to a reduction in blood oxygen level and acute poisoning. Harvesting the strong specific interaction between CO and the iron porphyrin provides a highly selective and customizable sensor. We report the development of chemiresistive sensors with voltage-activated sensitivity for the detection of CO comprising iron porphyrin and functionalized single-walled carbon nanotubes (F-SWCNTs). Modulation of the gate voltage offers a predicted extra dimension for sensing. Specifically, the sensors show a significant increase in sensitivity toward CO when negative gate voltage is applied. The dosimetric sensors are selective to ppm levels of CO and functional in air. UV/Vis spectroscopy, differential pulse voltammetry, and density functional theory reveal that the in situ reduction of FeIII to FeII enhances the interaction between the F-SWCNTs and CO. Our results illustrate a new mode of sensors wherein redox active recognition units are voltage-activated to give enhanced and highly specific responses.

  1. Use of pulse co-oximetry as a screening and monitoring tool in mass carbon monoxide poisoning.

    Science.gov (United States)

    Bledsoe, Bryan E; Nowicki, Kevin; Creel, James H; Carrison, Dale; Severance, Harry W

    2010-01-01

    Carbon monoxide (CO) poisoning remains a common cause of poisoning in the United States. We describe a case where responding fire department personnel encountered a sick employee with a headache at an automotive brake manufacturing plant. Using both atmospheric CO monitoring and pulse CO-oximetry technology, fire department personnel were able to diagnose the cause of the patient's illness and later identify the source of CO in the plant.

  2. First principles description of the insulator-metal transition in europium monoxide

    KAUST Repository

    Wang, Hao

    2012-02-01

    Europium monoxide, EuO, is a ferromagnetic insulator. Its electronic structure under pressure and doping is investigated by means of density functional theory. We employ spin polarized electronic structure calculations including onsite electron-electron interaction for the localized Eu 4f and 5d electrons. Our results show that under pressure the ferromagnetism is stable, both for hydrostatic and uniaxial pressure, while the compound undergoes an insulator-metal transition. The insulator-metal transition in O deficient and Gd doped EuO is reproduced for an impurity concentration of 6.25%. A 10 monolayer thick EuO(1 0 0) thin film is predicted to be an insulator with a narrow band gap of 0.08 eV. © 2011 Elsevier B.V. All rights reserved.

  3. Role of carboxydobacteria in consumption of atmospheric carbon monoxide by soil

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, R. (Max-Planck-Institut fuer Chemie, Mainz, Germany); Meyer, O.; Seiler, W.

    1981-08-01

    The carbon monoxide consumption rates of the carboxydobacteria Pseudomonas (Seliberia) carboxydohydrogena, P. carboxydovorans, and P. carboxydoflava were measured at high (50%) and low (0.5 ..mu..l liter/sup -1/) mixing ratios of CO in air. CO was only consumed when the bacteria had been grown under CO-autotrophic conditions. At low cell densities the CO comsumption rates measured at low CO mixing ratios were similar in cell suspensions and in mixtures of bacteria in soil. CO consumption observed in natural soil (loess, eolian sand, chernozem) as well as in suspensions or soil mixtures of carboxydobacteria showed Michaelis-Menten kinetics. Considering the difference of the K/sub m/, values and the observed V/sub max/ values, carboxydobacteria cannot contribute significantly to the consumption of atmospheric CO.

  4. Cobalt Oxide Nanosheet and CNT Micro Carbon Monoxide Sensor Integrated with Readout Circuit on Chip

    Directory of Open Access Journals (Sweden)

    Ching-Liang Dai

    2010-03-01

    Full Text Available The study presents a micro carbon monoxide (CO sensor integrated with a readout circuit-on-a-chip manufactured by the commercial 0.35 μm complementary metal oxide semiconductor (CMOS process and a post-process. The sensing film of the sensor is a composite cobalt oxide nanosheet and carbon nanotube (CoOOH/CNT film that is prepared by a precipitation-oxidation method. The structure of the CO sensor is composed of a polysilicon resistor and a sensing film. The sensor, which is of a resistive type, changes its resistance when the sensing film adsorbs or desorbs CO gas. The readout circuit is used to convert the sensor resistance into the voltage output. The post-processing of the sensor includes etching the sacrificial layers and coating the sensing film. The advantages of the sensor include room temperature operation, short response/recovery times and easy post-processing. Experimental results show that the sensitivity of the CO sensor is about 0.19 mV/ppm, and the response and recovery times are 23 s and 34 s for 200 ppm CO, respectively.

  5. Carbon monoxide migratory insertion - A comparison of cationic and neutral palladium(II) complexes

    International Nuclear Information System (INIS)

    Frankcombe, K.; Cavell, K.J.; Yates, B.F.; Knott, R.B.

    1998-01-01

    With the use of ANSTO's resources and expertise and with support from AINSE, we have carried out extensive computer modelling on the mechanism of the palladium catalysed carbonylation reaction, a process which is used industrially in the conversion of carbon monoxide into biodegradable polymers. In this project, experimental and theoretical work has focussed on using Pd(II) complexes containing pyridine carboxylate ligands (NC 5 H 4 COO ) to explore the fundamental mechanistic steps. The results for subsequent steps in the catalytic cycle are presented and their implication for the design of more efficient catalysts are discussed

  6. The relation between carbon monoxide emission and visual extinction in cloud L134

    International Nuclear Information System (INIS)

    Tucker, K.D.; Dickman, R.L.; Encrenaz, P.J.; Kutner, M.L.

    1976-01-01

    Emission from the J=1→0 transition of carbon monoxide has been mapped over an area of 40' x 55' in cloud L134, and visual extinctions over the entire cloud have been obtained by means of star counts. Line intensities of > or =2 K are observable down to an extinction level of about one magnitude. From observations of the J=1→0 transition of the 13 CO isotopic species at 18 locations in the cloud, we have found a linear correlation between the local thermodynamic equilibrium (LTE) column densities of 13 CO and magnitudes of visual extinction

  7. The Role of Physical and Physiological Capacities and Their Modification on the Tolerance to Various Stress Experienced by Air Force Personnel

    Science.gov (United States)

    1984-06-30

    2. To partition the energy utilization during HSG and RTE into oxidation of fat and carbohydrate components; and glycogen utilization and lactate...and physical conditioning. Given the entrance of women into the Air Force Academy and the acknowledged interaction of thermoregulation-dehydration on...basketball, wrestling, soccer and cross-country teams. E-7. CO2 Rebreathing Method The final noninvasive method of assessing cardiac function was the

  8. Catalytic hydrogenation of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Wayland, B.B.

    1992-12-01

    This project is focused on developing strategies to accomplish the reduction and hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. Our approaches to this issue are based on the recognition that rhodium macrocycles have unusually favorable thermodynamic values for producing a series of intermediate implicated in the catalytic hydrogenation of CO. Observations of metalloformyl complexes produced by reactions of H{sub 2} and CO, and reductive coupling of CO to form metallo {alpha}-diketone species have suggested a multiplicity of routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in constructing energy profiles for a variety of potential pathways, and these schemes are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Variation of the electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Emerging knowledge of the factors that contribute to M-H, M-C and M-O bond enthalpies is directing the search for ligand arrays that will expand the range of metal species that have favorable thermodynamic parameters to produce the primary intermediates for CO hydrogenation. Studies of rhodium complexes are being extended to non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics. Multifunctional catalyst systems designed to couple the ability of rhodium complexes to produce formyl and diketone intermediates with a second catalyst that hydrogenates these imtermediates are promising approaches to accomplish CO hydrogenation at mild conditions.

  9. Reactivity of niobium cluster anions with nitrogen and carbon monoxide

    Science.gov (United States)

    Mwakapumba, Joseph; Ervin, Kent M.

    1997-02-01

    Reactions of small niobium cluster anions, Nbn-(n = 2-7), with CO and N2 are investigated using a flow tube reactor (flowing afterglow) apparatus. Carbon monoxide chemisorption on niobium cluster anions occurs with faster reaction rates than nitrogen chemisorption on corresponding cluster sizes. N2 addition to niobium cluster anions is much more size-selective than is CO addition. These general trends follow those reported in the literature for reactions of neutral and cationic niobium clusters with CO and N2. Extensive fragmentation of the clusters is observed upon chemisorption. A small fraction of the larger clusters survive and sequentially add multiple CO or N2 units without fragmentation. However, chemisorption saturation is not reached at the experimentally accessible pressure and reagent concentration ranges. The thermochemistry of the adsorption processes and the nature of the adsorbed species, molecular or dissociated, are discussed.

  10. Extension of the code COCOSYS to a dispersion code for smoke and carbon monoxide

    International Nuclear Information System (INIS)

    Sdouz, Gert; Mayrhofer, Robert

    2009-01-01

    The code COCOSYS (Containment Code SYStem) was developed by GRS in Germany to simulate processes and nuclear plant states during severe accidents in the containments of light water reactors. It contains several physical models, especially a module for aerosol behaviour. The goal of this work was to extend COCOSYS for applications in more general geometries mainly for complex public buildings. For the application in public buildings models for air condition systems and different boundary conditions according to different environments were developed. The principal application of the extended code COCOSYS is in the area of emergency situations especially in the simulation for carbon monoxide and smoke dispersion. After developing and implementing the new models several test calculations were performed to evaluate the functionality of the extended code. The comparison of the results with those of the original COCOSYS code showed no discrepancies. For the first realistic application several fire emergency scenarios in the Vienna General Hospital (AKH) were selected in agreement with the fire department of the hospital. One of the scenarios addresses the danger of carbon monoxide (CO) and smoke leaking into a fire protection section through a damaged fire protection flap. As a result of the dispersion simulation the CO-concentration in all of the rooms is obtained. Together with additional results as deposition and smoke dispersion the outcome of the simulation can be used for training. Among the next steps are the validation of the new models and the selection of critical scenarios. (author)

  11. Single-, double-, and triple-photoionization cross sections of carbon monoxide (CO) and ionic fragmentation of CO+, CO2+, and CO3+

    International Nuclear Information System (INIS)

    Masuoka, T.; Nakamura, E.

    1993-01-01

    Single-, double-, and triple-photoionization processes of carbon monoxide (CO) have been studied in the photon-energy region of 37--100 eV by use of time-of-flight mass spectrometry and a photoion-photoion-coincidence method together with synchrotron radiation. The single-, double-, and triple-photoionization cross sections of CO are determined. Ion branching ratios and the partial cross sections for the individual ions respectively produced from the precursors CO + and CO 2+ are determined separately at excitation energies where the molecular and dissociative single- and double-photoionization processes compete. The threshold for the molecular double photoionization was found to be 41.3±0.2 eV. Furthermore, in single photoionization, the production of CO + is dominant whereas with double photoionization dissociation becomes dominant

  12. 0.1–2000 eV electron impact cross sections for dichlorine monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Goswami, Biplab; Gupta, Dhanoj; Antony, Bobby, E-mail: bka.ism@gmail.com

    2014-03-01

    Highlights: • Quantum mechanical models were used to find TCS for e-Cl{sub 2}O from 0.1 to 2000 eV. • R-matrix method at low energies (<13 eV) and SCOP at high energies (13–2000 eV). • Besides TCS, DCS, excitation cross section and momentum transfer CS also predicted. • R-matrix method identifies resonances with a possibility of DEA formation. • Resonance detected at 1.88 eV is associated with Cl{sub 2}O{sup −} anion formation. - Abstract: Scattering dynamics of dichlorine monoxide (Cl{sub 2}O) molecule by electron impact is investigated as a function of electron energy and scattering angle. Electron impact total cross sections for Cl{sub 2}O over an extensive range of impact energies from 0.1 to 2000 eV are reported in this article. Below the ionization threshold of the target, the ab initio R-matrix method and above this incident energy spherical complex optical potential formalism are used for cross section calculation. The total cross section obtained from both theories merges smoothly at the overlapping energy. The resonances obtained using DZP basis sets are located at 1.883, 3.592, 5.205 and 7.326, 8.206, 8.301, 8.452, 9.369 eV and that with 6-31G* basis sets are identified at 1.944, 3.566, 5.183, 5.261, 5.658, 8.738 and 9.187 eV with the possibility of negative ions formation. This is the first attempt to calculate the differential, and momentum transfer cross sections for Cl{sub 2}O molecule.

  13. Oxygen permeation flux through La1-ySryFeO3 limited by the carbon monoxide oxidation rate

    NARCIS (Netherlands)

    van Hassel, B.A.; van Hassel, B.A.; ten Elshof, Johan E.; Bouwmeester, Henricus J.M.

    1995-01-01

    The oxygen permeation flux through La1-ySryFeO3-δ (y = 0.1, 0.2) in a large oxygen partial pressure gradient (air/CO, CO2 mixture) was found to be limited by the carbon monoxide oxidation rate at the low oxygen partial pressure side of the membrane. The oxygen permeation flux through the membrane

  14. Clinical and neuropathological findings of acute carbon monoxide toxicity in chihuahuas following smoke inhalation.

    Science.gov (United States)

    Kent, Marc; Creevy, Kate E; Delahunta, Alexander

    2010-01-01

    Three adult Chihuahuas were presented for evaluation after smoke inhalation during a house fire. All three dogs received supportive care and supplemental oxygen. After initial improvement, the dogs developed seizures. Despite anticonvulsant therapy and supportive care, the dogs died. The brains of two dogs were examined. Lesions were identified that were compatible with acute carbon monoxide (CO) toxicity. Lesions were confined to the caudate nucleus, the globus pallidus, and the substantia nigra bilaterally, as well as the cerebellum, cerebral cortex, and dorsal thalamus. This case report describes the clinicopathological sequelae in acute CO toxicity.

  15. Regional air-quality forecasting for the Pacific Northwest using MOPITT/TERRA assimilated carbon monoxide MOZART-4 forecasts as a near real-time boundary condition

    Directory of Open Access Journals (Sweden)

    F. L. Herron-Thorpe

    2012-06-01

    Full Text Available Results from a regional air quality forecast model, AIRPACT-3, were compared to AIRS carbon monoxide column densities for the spring of 2010 over the Pacific Northwest. AIRPACT-3 column densities showed high correlation (R > 0.9 but were significantly biased (~25% with consistent under-predictions for spring months when there is significant transport from Asia. The AIRPACT-3 CO bias relative to AIRS was eliminated by incorporating dynamic boundary conditions derived from NCAR's MOZART forecasts with assimilated MOPITT carbon monoxide. Changes in ozone-related boundary conditions derived from MOZART forecasts are also discussed and found to affect background levels by ± 10 ppb but not found to significantly affect peak ozone surface concentrations.

  16. Iron metal-organic frameworks MIL-88B and NH2-MIL-88B for the loading and delivery of the gasotransmitter carbon monoxide.

    Science.gov (United States)

    Ma, Mingyan; Noei, Heshmat; Mienert, Bernd; Niesel, Johanna; Bill, Eckhard; Muhler, Martin; Fischer, Roland A; Wang, Yuemin; Schatzschneider, Ulrich; Metzler-Nolte, Nils

    2013-05-17

    Crystals of MIL-88B-Fe and NH2-MIL-88B-Fe were prepared by a new rapid microwave-assisted solvothermal method. High-purity, spindle-shaped crystals of MIL-88B-Fe with a length of about 2 μm and a diameter of 1 μm and needle-shaped crystals of NH2-MIL-88B-Fe with a length of about 1.5 μm and a diameter of 300 nm were produced with uniform size and excellent crystallinity. The possibility to reduce the as-prepared frameworks and the chemical capture of carbon monoxide in these materials was studied by in situ ultrahigh vacuum Fourier-transform infrared (UHV-FTIR) spectroscopy and Mössbauer spectroscopy. CO binding occurs to unsaturated coordination sites (CUS). The release of CO from the as-prepared materials was studied by a myoglobin assay in physiological buffer. The release of CO from crystals of MIL-88B-Fe with t(1/2) = 38 min and from crystals of NH2-MIL-88B-Fe with t(1/2) = 76 min were found to be controlled by the degradation of the MIL materials under physiological conditions. These MIL-88B-Fe and NH2-MIL-88B-Fe materials show good biocompatibility and have the potential to be used in pharmacological and therapeutic applications as carriers and delivery vehicles for the gasotransmitter carbon monoxide. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Deep Conversion of Carbon Monoxide to Hydrogen and Formation of Acetate by the Anaerobic Thermophile Carboxydothermus hydrogenoformans

    OpenAIRE

    Henstra, Anne M.; Stams, Alfons J. M.

    2011-01-01

    Carboxydothermus hydrogenoformans is a thermophilic strictly anaerobic bacterium that catalyses the water gas shift reaction, the conversion of carbon monoxide with water to molecular hydrogen and carbon dioxide. The thermodynamically favorable growth temperature, compared to existing industrial catalytic processes, makes this organism an interesting alternative for production of cheap hydrogen gas suitable to fuel CO-sensitive fuel cells in a future hydrogen economy, provided sufficiently lo...

  18. Effects of chronic carbon monoxide exposure on fetal growth and development in mice

    Directory of Open Access Journals (Sweden)

    Venditti Carolina C

    2011-12-01

    Full Text Available Abstract Background Carbon monoxide (CO is produced endogenously, and can also be acquired from many exogenous sources: ie. cigarette smoking, automobile exhaust. Although toxic at high levels, low level production or exposure lends to normal physiologic functions: smooth muscle cell relaxation, control of vascular tone, platelet aggregation, anti- inflammatory and anti-apoptotic events. In pregnancy, it is unclear at what level maternal CO exposure becomes toxic to the fetus. In this study, we hypothesized that CO would be embryotoxic, and we sought to determine at what level of chronic CO exposure in pregnancy embryo/fetotoxic effects are observed. Methods Pregnant CD1 mice were exposed to continuous levels of CO (0 to 400 ppm from conception to gestation day 17. The effect on fetal/placental growth and development, and fetal/maternal CO concentrations were determined. Results Maternal and fetal CO blood concentrations ranged from 1.12- 15.6 percent carboxyhemoglobin (%COHb and 1.0- 28.6%COHb, respectively. No significant difference was observed in placental histological morphology or in placental mass with any CO exposure. At 400 ppm CO vs. control, decreased litter size and fetal mass (p Conclusions Exposure to levels at or below 300 ppm CO throughout pregnancy has little demonstrable effect on fetal growth and development in the mouse.

  19. Synthesis of Nano sized Zinc-Doped Cobalt Oxyhydroxide Parties by a Dropping Method and Their Carbon Monoxide Gas Sensing Properties

    International Nuclear Information System (INIS)

    Wang, J.W.; Kuo, Y.M.

    2013-01-01

    Two nano structures of cobalt oxyhydroxide (CoOOH) and Zinc-(Zn-) doped CoOOH (1–4% Zn) are prepared from Co(NO 3 ) 2 solution via microtitration with NaOH and oxidation in air. The X-ray diffraction (XRD) analysis results show that a pure state of nano-CoOOH can be obtained at an alkalinity (OH−/Co + ) of 5 with 40°C heat treatment after 6 h. The Zn ions preferentially substitute Co ions in the CoOOH structure, resulting in a decrease of its crystallinity. The disc-like CoOOH nano structure exhibits good sensitivity to carbon monoxide (CO) in a temperature range of 40–110°C with maximum sensitivity to CO at around 70–80°C. When CoOOH nano structure is doped with 1% Zn, its sensitivity and selectivity for CO gas are improved at 70–80°C; further Zn doping to 2% degraded the CO sensing properties of nano-CoOOH. The results of a cross-sensitivity investigation of the sensor to various gases coexisting at early stages of a fire show that the sensitivity of Zn-doped nano-CoOOH is the highest toward CO. Zn-doped nano-CoOOH film exhibits a high sensitivity to CO at room temperature, making it a promising sensor for early-stage fire detection.

  20. Multi-objective optimisation in carbon monoxide gas management at TRONOX KXN Sands

    Directory of Open Access Journals (Sweden)

    Stadler, Johan

    2014-08-01

    Full Text Available Carbon monoxide (CO is a by-product of the ilmenite smelting process from which titania slag and pig iron are produced. Prior to this project, the CO at Tronox KZN Sands in South Africa was burnt to get rid of it, producing carbon dioxide (CO2. At this plant, unprocessed materials are pre-heated using methane gas from an external supplier. The price of methane gas has increased significantly; and so this research considers the possibility of recycling CO gas and using it as an energy source to reduce methane gas demand. It is not possible to eliminate the methane gas consumption completely due to the energy demand fluctuation, and sub-plants have been assigned either CO gas or methane gas over time. Switching the gas supply between CO and methane gas involves production downtime to purge supply lines. Minimising the loss of production time while maximising the use of CO arose as a multi-objective optimisation problem (MOP with seven decision variables, and computer simulation was used to evaluate scenarios. We applied computer simulation and the multi-objective optimisation cross-entropy method (MOO CEM to find good solutions while evaluating the minimum number of scenarios. The proposals in this paper, which are in the process of being implemented, could save the company operational expenditure while reducing the carbon footprint of the smelter.

  1. RARE ISOTOPIC SPECIES OF SULFUR MONOXIDE: THE ROTATIONAL SPECTRUM IN THE THz REGION

    Energy Technology Data Exchange (ETDEWEB)

    Lattanzi, Valerio; Cazzoli, Gabriele; Puzzarini, Cristina, E-mail: lattanzi@mpe.mpg.de [Dipartimento di Chimica “Giacomo Ciamician,” Università di Bologna, Via Selmi 2, I-40126 Bologna (Italy)

    2015-11-01

    Many sulfur-bearing species have been detected in different astronomical environments and have allowed us to derive important information about the chemical and physical composition of interstellar regions. In particular, these species have also been shown to trace and probe hot-core environment time evolution. Among the most prominent sulfur-bearing molecules is SO, the sulfur monoxide radical, one of the more ubiquitous and abundant, which is also observed in its isotopic substituted species such as {sup 34}SO and S{sup 18}O. Due to the importance of this simple diatomic system, and in order to face the challenge of modern radioastronomical facilities, an extension to the THz range of the rare isotopologues of sulfur monoxide has been performed. High-resolution rotational molecular spectroscopy has been employed to extend the available data set of four isotopic species, SO, {sup 34}SO, S{sup 17}O, and S{sup 18}O, up to the 1.5 THz region. The frequency coverage and spectral resolution of our measurements allowed a better constraint of the molecular constants of the four species considered, specifically focusing on the two oxygen-substituted isotopologues. Our measurements were also employed in an isotopically invariant fit including all of the available pure rotational and ro-vibrational transitions for all of the SO isotopologues, thus enabling accurate predictions of the rotational transitions at higher frequencies. We also provide comparisons with recent works performed on the same system, demonstrating the quality of our experiment and the improvement of the data sets for all of the species considered. Transition frequencies for this system can now be used with confidence by the astronomical community well into the THz spectral region.

  2. Enhancement of p-type mobility in tin monoxide by native defects

    KAUST Repository

    Granato, D. B.

    2013-05-31

    Transparent p-type materials with good mobility are needed to build completely transparent p-n junctions. Tin monoxide (SnO) is a promising candidate. A recent study indicates great enhancement of the hole mobility of SnO grown in Sn-rich environment [E. Fortunato et al., Appl. Phys. Lett. 97, 052105 (2010)]. Because such an environment makes the formation of defects very likely, we study defect effects on the electronic structure to explain the increased mobility. We find that Sn interstitials and O vacancies modify the valence band, inducing higher contributions of the delocalized Sn 5p orbitals as compared to the localized O 2p orbitals, thus increasing the mobility. This mechanism of valence band modification paves the way to a systematic improvement of transparent p-type semiconductors.

  3. Investigation of Carbon Monoxide Adsorption on Cationic Gold- Palladium Clusters

    Science.gov (United States)

    Chen, Yang-Mei; Kuang, Xiao-Yu; Sheng, Xiao-Wei; Wang, Huai-Qian; Shao, Peng; Zhong, Min-Ming

    2013-11-01

    Density functional calculations have been performed for the carbon monoxide molecule adsorption on AunPd+m(n+m ≤ 6) clusters. In the process of CO adsorption, small Au clusters and Pd clusters tend to be an Au atom and three Pd atoms adsorption, respectively. For the mixed Au-Pd clusters, an Au atom, a Pd atom, two atoms consisted of an Au atom and a Pd atom, two Pd atoms, and three Pd atoms adsorption structures are displayed. The highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) gaps and natural bond orbital charge population are calculated. Moreover, CO adsorption energy, CO stretching frequency, and CO bond length (upon adsorption) are also analysed in detail. The results predict that the adsorption strength of Au clusters with CO and the C-O vibration strength is enhanced and reduced after doping of Pd in the AunPdmCO+ complexes, respectively

  4. Carbon monoxide exposure and information processing during perceptual-motor performance

    Energy Technology Data Exchange (ETDEWEB)

    Mihevic, P.M.; Gliner, J.A.; Horvath, S.M.

    1983-01-01

    This study examined the influence of exposure to ambient carbon monoxide resulting in final carboxyhemoglobin (COHb) levels of approximately 5.0% on the ability to process information during motor performance. Subjects (n . 16) performed a primary reciprocal tapping task and a secondary digit manipulation task singly and/or concurrently during 2.5 h exposure to room air (0 ppm CO) or 100 ppm CO. Five levels of tapping difficulty and two levels of digit manipulation were employed. Tapping performance was unaffected when COHb levels were as high as 5%. However, at this level of COHb it was noted that CO exposure interacted with task difficulty of both tasks to influence reaction time on the digit manipulation task. It was concluded that motor performance was not influenced by exposure to CO leading to COHb concentrations of 5%. Task difficulty was a significant factor mediating behavioral effects of CO exposure.

  5. Carbon monoxide exposure and information processing during perceptual-motor performance

    Energy Technology Data Exchange (ETDEWEB)

    Mihevic, P.M.; Gliner, J.A.; Horvath, S.M.

    1983-04-01

    This study examined the influence of exposure to ambient carbon monoxide resulting in final carboxyhemoglobin (COHb) levels of approximately 5.0% on the ability to process information during motor performance. Subjects (n = 16) performed a primary reciprocal tapping task and a secondary digit manipulation task singly and/or concurrently during 2.5 h exposure to room air (0 ppm CO) or 100 ppm CO. Five levels of tapping difficulty and two levels of digit manipulation were employed. Tapping performance was unaffected when COHb levels were as high as 5%. However, at this level of COHb it was noted that CO exposure interacted with task difficulty of both tasks to influence reaction time on the digit manipulation task. It was concluded that motor performance was not influenced by exposure to CO leading to COHb concentrations of 5%. Task difficulty was a significant factor mediating behavioral effects of CO exposure.

  6. Dispersive oxidation of rhodium clusters in Na-Y by the combined action of zeolite protons and carbon monoxide

    International Nuclear Information System (INIS)

    Wong, T.T.T.; Sachtler, W.M.H.; Stakheev, A.Yu.

    1992-01-01

    This paper uses x-ray photoelectron spectroscopy, fourier transform infrared spectroscopy and temperature programmed mass-spectrometric analysis to study the interaction of Na-Y supported rhodium with hydrogen, carbon monoxide, and zeolite protons. This report attempts to clarify the mechanism of dispersive oxidation of reduced Rh particles in the presence of CO, leading to the formation of Rh + (CO) 2 cations

  7. DNA pooling base genome-wide association study identifies variants at NRXN3 associated with delayed encephalopathy after acute carbon monoxide poisoning.

    Directory of Open Access Journals (Sweden)

    Wenqiang Li

    Full Text Available Delayed encephalopathy after acute carbon monoxide poisoning (DEACMP is more characteristic of anoxic encephalopathy than of other types of anoxia. Those who have the same poisoning degree and are of similar age and gender have a greater risk of getting DEACMP. This has made it clear that there are obvious personal differences. Genetic factors may play a very important role. The authors performed a genome-wide association study involving pooling of DNA obtained from 175 patients and 244 matched acute carbon monoxide poisoning without delayed encephalopathy controls. The Illumina HumanHap 660 Chip array was used for DNA pools. Allele frequencies of all SNPs were compared between delayed encephalopathy after acute carbon monoxide poisoning and control groups and ranked. A total of 123 SNPs gave an OR >1.4. Of these, 46 mapped in or close to known genes. Forty-eight SNPs located in 19 genes were associated with DEACMP after correction for 5% FDR in the genome-wide association of pooled DNA. Two SNPs (rs11845632 and rs2196447 locate in the Neurexin 3 gene were selected for individual genotyping in all samples and another cohort consisted of 234 and 271 controls. There were significant differences in the genotype and allele frequencies of rs11845632 and rs2196447 between the DEACMP group and controls group (all P-values <0.05. This study describes a positive association between Neurexin 3 and controls in the Han Chinese population, and provides genetic evidence to support the susceptibility of DEACMP, which may be the resulting interaction of environmental and genetic factors.

  8. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    International Nuclear Information System (INIS)

    Geballe, T.R.; Lacy, J.H.; Beck, S.C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is proabably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial

  9. The 8 micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Science.gov (United States)

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1979-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (about 600 K) layers of a circumstellar cloud at a distance of approximately 0.15 arcsec from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  10. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Science.gov (United States)

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  11. Cobalt doped CuMnOx catalysts for the preferential oxidation of carbon monoxide

    Science.gov (United States)

    Dey, Subhashish; Dhal, Ganesh Chandra; Mohan, Devendra; Prasad, Ram; Gupta, Rajeev Nayan

    2018-05-01

    Carbon monoxide (CO) is a poisonous gas, recognized as a silent killer for the 21st century. It is produced from the partial oxidation of carbon containing compounds. The catalytic oxidation of CO receives a huge attention due to its applications in different fields. In the present work, hopcalite (CuMnOx) catalysts were synthesized using a co-precipitation method for CO oxidation purposes. Also, it was doped with the cobalt by varying concentration from 1 to 5wt%. It was observed that the addition of cobalt into the CuMnOx catalyst (by the deposition-precipitation method) improved the catalytic performance for the low-temperature CO oxidation. CuMnOx catalyst doped with 3wt% of cobalt exhibited most active performance and showed the highest activity than other cobalt concentrations. Different analytical tools (i.e. XRD, FTIR, BET, XPS and SEM-EDX) were used to characterize the as-synthesized catalysts. It was expected that the introduction of cobalt will introduce new active sites into the CuMnOx catalyst that are associated with the cobalt nano-particles. The order of calcination strategies based on the activity for cobalt doped CuMnOx catalysts was observed as: Reactive calcinations (RC) > flowing air > stagnant air. Therefore, RC (4.5% CO in air) route can be recommended for the synthesis of highly active catalysts. The catalytic activity of doped CuMnOx catalysts toward CO oxidation shows a correlation among average oxidation number of Mn and the position and the nature of the doped cobalt cation.

  12. Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

    Science.gov (United States)

    Verbanck, S.; Larsson, H.; Linnarsson, D.; Prisk, G. K.; West, J. B.; Paiva, M.

    1997-01-01

    In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

  13. Method of handling radioactive alkali metal waste

    Science.gov (United States)

    Wolson, R.D.; McPheeters, C.C.

    Radioactive alkali metal is mixed with particulate silica in a rotary drum reactor in which the alkali metal is converted to the monoxide during rotation of the reactor to produce particulate silica coated with the alkali metal monoxide suitable as a feed material to make a glass for storing radioactive material. Silica particles, the majority of which pass through a 95 mesh screen or preferably through a 200 mesh screen, are employed in this process, and the preferred weight ratio of silica to alkali metal is 7 to 1 in order to produce a feed material for the final glass product having a silica to alkali metal monoxide ratio of about 5 to 1.

  14. Method of handling radioactive alkali metal waste

    International Nuclear Information System (INIS)

    Mcpheeters, C.C.; Wolson, R.D.

    1980-01-01

    Radioactive alkali metal is mixed with particulate silica in a rotary drum reactor in which the alkali metal is converted to the monoxide during rotation of the reactor to produce particulate silica coated with the alkali metal monoxide suitable as a feed material to make a glass for storing radioactive material. Silica particles, the majority of which pass through a 95 mesh screen or preferably through a 200 mesh screen, are employed in this process, and the preferred weight ratio of silica to alkali metal is 7 to 1 in order to produce a feed material for the final glass product having a silica to alkali metal monoxide ratio of about 5 to 1

  15. Residential carbon monoxide poisoning from motor vehicles.

    Science.gov (United States)

    Hampson, Neil B

    2011-01-01

    Although morbidity and mortality from accidental carbon monoxide (CO) poisoning are high in the United States, identification of common but poorly recognized sources should help prevention efforts. The study aimed to describe CO poisoning of home occupants due to a vehicle left running in an attached garage. News stories reporting incidents of US CO poisoning were collected daily from March 2007 to September 2009 via a news.Google.com search and data extracted. Patients were individuals reported in the media to have been poisoned with CO in their home by a vehicle running in the attached garage. Main outcome measures were frequency of occurrence, geographic distribution, patient demographics, and mortality. Of 837 CO poisoning incidents reported in US news media over 2 and a half years, 59 (8%) were the result of a vehicle left running in the garage. The elderly were disproportionately affected, with incidents most common in states with larger elderly populations and 29% of cases with age specified occurring in individuals older than 80 years. Among those older than 80 years, 15 of 17 were found dead at the scene. Residential CO poisoning from a vehicle running in the garage is common, disproportionately affects the elderly, has a high mortality rate, and should be preventable with a residential CO alarm. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. CT of the brain in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Ohno, Masato; Uchino, Akira; Hayashi, Kazuji; Nakata, Hajime.

    1988-01-01

    Cerebral computed tomographic (CT) findings of acute carbon monoxide (Co) poisoning were analized in thirty-six cases treated with hyperbraric oxygen therapy and their relationship with prognosis was evaluated. The cases were classified into there groups, early stage, interval form, and non-interval form groups. In all groups, the initial abnormality was low density areas presumably due to edema, demyelination and/or softening. It was seen in the globus pallidus and/or white matter. Following these initial changes, cerebral hemorrhage, ventricular dilatation, and cerebral atrophy developed in a few cases. The frequency of abnormal CT findings was higher in the interval form group (85 %) or non-interval group (83 %) than the early stage group (41 %). The prognosis was good in most cases with normal CT findings. The possibility of recovery diminished in the patients with abnormal CT findings. The prognosis was particularly poor in cases showing abnormality both in globus pallidus and white matter. We conclude that CT is useful not only for detecting the pathologic change but also for predicting the prognosis of the patient with acute Co poisoning. (author)

  17. Report on evaluation of research and development of methods for producing basic chemicals from carbon monoxide and other stocks; Issanka tanso nado wo genryo to suru kiso kagakuhin no seizoho no kenkyu kaihatsu ni kansuru hyoka hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-08-01

    This project was aimed at developing methods for producing basic chemicals from carbon monoxide and other stocks (the so-called C1 chemistry), in order to establish the techniques that could promote stable supply of basic chemicals from the new carbon resources in place of oil. It was a 7-year national project beginning in FY 1980, jointly implemented by the government, academic and industrial circles. Described herein are the overall evaluation of the results. There are several carbon resources other than oil, e.g., coal, natural gas, oil shale and tar sand. They are abundantly occurring, although unevenly, and various countries are developing these resources. They can be advantageously utilized as stocks for chemicals, after being converted into synthesis gases. In Japan, they have been efficiently developed cooperatively by national institutes, enterprises, academic circles and chemical industry, to produce the world's results, e.g., gas separation/purification techniques and new catalysts for new synthesis methods. This project was terminated because of the relaxed oil supply/demand situations and lowered crude prices in the middle of the 80's, which made stock conversion less urgent. (NEDO)

  18. Report on evaluation of research and development of methods for producing basic chemicals from carbon monoxide and other stocks; Issanka tanso nado wo genryo to suru kiso kagakuhin no seizoho no kenkyu kaihatsu ni kansuru hyoka hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-08-01

    This project was aimed at developing methods for producing basic chemicals from carbon monoxide and other stocks (the so-called C1 chemistry), in order to establish the techniques that could promote stable supply of basic chemicals from the new carbon resources in place of oil. It was a 7-year national project beginning in FY 1980, jointly implemented by the government, academic and industrial circles. Described herein are the overall evaluation of the results. There are several carbon resources other than oil, e.g., coal, natural gas, oil shale and tar sand. They are abundantly occurring, although unevenly, and various countries are developing these resources. They can be advantageously utilized as stocks for chemicals, after being converted into synthesis gases. In Japan, they have been efficiently developed cooperatively by national institutes, enterprises, academic circles and chemical industry, to produce the world's results, e.g., gas separation/purification techniques and new catalysts for new synthesis methods. This project was terminated because of the relaxed oil supply/demand situations and lowered crude prices in the middle of the 80's, which made stock conversion less urgent. (NEDO)

  19. In situ disordering of monoclinic titanium monoxide Ti5O5 studied by transmission electron microscope TEM.

    Science.gov (United States)

    Rempel, А А; Van Renterghem, W; Valeeva, А А; Verwerft, M; Van den Berghe, S

    2017-09-07

    The superlattice and domain structures exhibited by ordered titanium monoxide Ti 5 O 5 are disrupted by low energy electron beam irradiation. The effect is attributed to the disordering of the oxygen and titanium sublattices. This disordering is caused by the displacement of both oxygen and titanium atoms by the incident electrons and results in a phase transformation of the monoclinic phase Ti 5 O 5 into cubic B1 titanium monoxide. In order to determine the energies required for the displacement of titanium or oxygen atoms, i.e. threshold displacement energies, a systematic study of the disappearance of superstructure reflections with increasing electron energy and electron bombardment dose has been performed in situ in a transmission electron microscope (TEM). An incident electron energy threshold between 120 and 140 keV has been observed. This threshold can be ascribed to the displacements of titanium atoms with 4 as well as with 5 oxygen atoms as nearest neighbors. The displacement threshold energy of titanium atoms in Ti 5 O 5 corresponding with the observed incident electron threshold energy lies between 6.0 and 7.5 eV. This surprisingly low value can be explained by the presence of either one or two vacant oxygen lattice sites in the nearest neighbors of all titanium atoms.

  20. Effect of hyperbaric oxygen therapy on whole blood cyanide concentrations in carbon monoxide intoxicated patients from fire accidents

    DEFF Research Database (Denmark)

    Lawson-Smith, Pia; Jansen, Erik C; Hilsted, Linda

    2010-01-01

    Hydrogen cyanide (HCN) and carbon monoxide (CO) may be important components of smoke from fire accidents. Accordingly, patients admitted to hospital from fire accidents may have been exposed to both HCN and CO. Cyanide (CN) intoxication results in cytotoxic hypoxia leading to organ dysfunction...... and animal experiments have shown that in rats exposed to CN intoxication, HBO can increase the concentration of CN in whole blood....

  1. Onboard measurement system of atmospheric carbon monoxide in the Pacific by voluntary observing ships

    Directory of Open Access Journals (Sweden)

    H. Nara

    2011-11-01

    Full Text Available Long-term monitoring of carbon monoxide (CO mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruise routes: from Japan to Oceania, the United States, Canada, and Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3–5 years. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.

  2. Onboard measurement system of atmospheric carbon monoxide in the Pacific by voluntary observing ships

    Science.gov (United States)

    Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.

    2011-11-01

    Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruise routes: from Japan to Oceania, the United States, Canada, and Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 years. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.

  3. Foucault, surveillance, and carbon monoxide testing within stop-smoking services.

    Science.gov (United States)

    Grant, Aimee; Ashton, Kathryn; Phillips, Rhiannon

    2015-07-01

    Health professionals have adopted proactive testing for early evidence of disease. Researchers have identified that this leads to enumerated understandings and shapes behavior in productive ways. Smoking-cessation advisors regularly test clients for carbon monoxide (CO), but client views of this had not previously been explored. We interviewed 23 clients of a United Kingdom-based stop-smoking service regarding their experiences of CO testing. The majority of participants were successful quitters. We used ATLAS.ti 7 as a data-management tool during structured qualitative analysis. Our findings reveal that clients believed the results of their CO tests. Many became enumerated in their understanding, and thus placed themselves in a hierarchy with other members of their group. Almost all clients found that knowing their CO test score was motivating. We conclude that additional research is needed to understand the experiences of CO testing among clients who do not quit. © The Author(s) 2014.

  4. UV-induced carbon monoxide emission from sand and living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2012-01-01

    The global burden of carbon monoxide, CO, is rather uncertain. In this paper we address the potential of UV-induced CO emission by terrestrial surfaces. Real-time measurements of [CO] were made with a cavity enhanced laser connected in closed loop to either an ecosystem chamber or a leaf scale...... chamber. Sand and leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation and the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature, indicating an abiotic process. The emission of CO...... in response to the UV-component of natural solar radiation was also evident at the ecosystem scale. When scaled to the global level, the UV-induced emission of CO by the major types of terrestrial surfaces, living leaves and soil (here represented by sand), amounts up to 28 Tg yr−1. This source has...

  5. An Unusual Cause of Supraventricular Tachycardia: Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Suat Zengin

    2014-03-01

    Full Text Available      Carbon monoxide (CO is a toxic gas produced by the incomplete combustion of carbon-containing compounds. Exposure to high concentrations of CO can be letha and is the most common cause of death from poisoning worldwide. Cardiac manifestations after exposure to CO, including myocardial ischemia, heart failure, and arrhythmias, have been reported. A 28-year-old a patient was admitted to our emergency department with altered consciousness as a consequence of acute domestic exposure to CO from a stove. His carboxyhemoglobin level was 39%. The oxygen treatment was started promptly, and therapeutic red cell exchange was performed. An electrocardiogram revealed supraventricular tachycardia (SVT, and an echocardiographic examination demonstrated normal cardiac functions. To the best of our knowledge, this study is the second to report a case of SVT attack due to acute CO intoxication. This paper discusses the management of this complication in patients poisoned with CO.

  6. Liquefaction of lignohemicellulosic waste by processing with carbon monoxide and water

    Energy Technology Data Exchange (ETDEWEB)

    El-Saied, H

    1977-09-01

    The liquefaction of lignohemicellulosic waste by processing with carbon monoxide and water for 10 minutes at 250/sup 0/-440/sup 0/C and 40 to 70 atm initial pressure in a rocking autoclave produced benzene-soluble heavy oil in yields up to 80%. High conversion and yields were favored by high thermal stress, short reaction times, and sufficient hydrogen to prevent radical recombination in the critical liquefaction stages. The addition of sodium or calcium hydroxide, sodium carbonate, iron oxide, etc. in small amounts gave good oil yields under less severe conditions. Lignins from rice straw, bagasse, and other grasses gave higher yields than the woody lignin obtained from cotton stalks. In products obtained by liquefying black liquor lignohemicellulose from an Eyptian rice straw pulping plant, the hydrogen-carbon atomic ratio was 1.0 to 1.3:1.

  7. Carbon monoxide poisoning: a five year review at Tan Tock Seng Hospital, Singapore.

    Science.gov (United States)

    Handa, P K; Tai, D Y H

    2005-11-01

    Carbon monoxide poisoning (COP) is one of the leading causes of death from poisoning worldwide. There is no published study of COP in Singapore so far. All patients admitted with the diagnosis of COP to Tan Tock Seng Hospital (TTSH) over 5 years from 1999 to 2003 were retrospectively reviewed. The diagnosis was based on a history of potential exposure to carbon monoxide (CO) and elevated levels of carboxyhaemoglobin (COHb). The causes, demographic data, clinical presentations, management and complications were analysed. There were 12 patients with COP. Their average age was 38.9 (+/-11.8) years, with a male-to-female ratio of 3:1. Accidental COP (58.3%) was more common than intentional COP (41.7%). The most common cause of accidental COP was smoke inhalation from a faulty vehicle. Gas stove was the most preferred source for intentional poisoning. Presenting features were headache (83.3%), confusion (83.3%), coma (12.7%) and agitation (8.3%). The mean COHb level on admission was 35.9% (+/-13.6). All were treated with 100% oxygen. All the patients achieved normal levels of COHb within 24 hours of admission. Two (16.7%) required intubation for airway protection as they were comatose on arrival, of which 1 presented with very high level of COHb (48.1%) and was the only patient to be treated with hyperbaric oxygen. Acute complications were globus pallidus infarction (16.6%), acute respiratory distress syndrome (8.3%) and myocardial ischaemia (8.3%). Most of the patients (91.7%) were discharged well from the hospital. One patient developed parkinsonism after a follow-up of 2 years. There were no deaths. COP is relatively uncommon in Singapore. It has a low rate of short- and long-term complications.

  8. Observations of bromine monoxide transport in the Arctic sustained on aerosol particles

    Directory of Open Access Journals (Sweden)

    P. K. Peterson

    2017-06-01

    Full Text Available The return of sunlight in the polar spring leads to the production of reactive halogen species from the surface snowpack, significantly altering the chemical composition of the Arctic near-surface atmosphere and the fate of long-range transported pollutants, including mercury. Recent work has shown the initial production of reactive bromine at the Arctic surface snowpack; however, we have limited knowledge of the vertical extent of this chemistry, as well as the lifetime and possible transport of reactive bromine aloft. Here, we present bromine monoxide (BrO and aerosol particle measurements obtained during the March 2012 BRomine Ozone Mercury EXperiment (BROMEX near Utqiaġvik (Barrow, AK. The airborne differential optical absorption spectroscopy (DOAS measurements provided an unprecedented level of spatial resolution, over 2 orders of magnitude greater than satellite observations and with vertical resolution unable to be achieved by satellite methods, for BrO in the Arctic. This novel method provided quantitative identification of a BrO plume, between 500 m and 1 km aloft, moving at the speed of the air mass. Concurrent aerosol particle measurements suggest that this lofted reactive bromine plume was transported and maintained at elevated levels through heterogeneous reactions on colocated supermicron aerosol particles, independent of surface snowpack bromine chemistry. This chemical transport mechanism explains the large spatial extents often observed for reactive bromine chemistry, which impacts atmospheric composition and pollutant fate across the Arctic region, beyond areas of initial snowpack halogen production. The possibility of BrO enhancements disconnected from the surface potentially contributes to sustaining BrO in the free troposphere and must also be considered in the interpretation of satellite BrO column observations, particularly in the context of the rapidly changing Arctic sea ice and snowpack.

  9. The clinical and imaging characteristics of delayed encephalopathy after acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Huang Chuming; Yin Zhao; Fang Yannan; Hong Weimin; Zeng Xianjie; Wang Tianwen

    2008-01-01

    Objective: To discuss the clinical and imaging characteristics of delayed encephalopathy after acute carbon monoxide poisoning (DEACMP). Methods: The clinical data of 14 patients with DEACMP were respectively analyzed. Results: Initial symptom included mentally falling (MMSE rate < 20 points) in 14 patients (100%), incontinence of urine in 11 patients (78%). Relatively significant increase of hematoma (HCT) (average level 0.503±0.027) was found in 6 patients. Three kinds of brain magnetic resonance imaging (MRI) appearance including diffuse white matter lesion, cortical lesion and basal nuclei lesion often existed in association. Therapy for improving circulation was given in 14 patients, and therapy with hormone was given in 9 patients; with 85% improvement rate. 5 patients without hormone therapy but with improving circulation therapy also received improvement. Conclusion: High level of HCT might be one of the causes of DECACMP due to acute disturbance of brain micro-circulation.. Close monitoring the change of HCT levels should be adopted for at least 3-6 months during therapy. Therapy for improving circulation and for anti-agglutination of platelets should be performed besides the routine high-tension oxygen therapy. Low FA value on DTI indicates the occurrence of a demyelization change in the brain long tract fibers, which indicated therapeutic effect of hormone treatment. And, therefore it would be better to perform DTI scan before therapy for individualized therapy. (authors)

  10. Intermittent, low dose carbon monoxide exposure enhances survival and dopaminergic differentiation of human neural stem cells

    DEFF Research Database (Denmark)

    Dreyer-Andersen, Nanna; Almeida, Ana Sofia; Jensen, Pia

    2018-01-01

    Exploratory studies using human fetal tissue have suggested that intrastriatal transplantation of dopaminergic neurons may become a future treatment for patients with Parkinson's disease. However, the use of human fetal tissue is compromised by ethical, regulatory and practical concerns. Human stem...... cells constitute an alternative source of cells for transplantation in Parkinson's disease, but efficient protocols for controlled dopaminergic differentiation need to be developed. Short-term, low-level carbon monoxide (CO) exposure has been shown to affect signaling in several tissues, resulting...... in Parkinson's disease....

  11. Calculation of the magnetic susceptibilities of transition metal monocarbides, mononitrides and monoxides

    International Nuclear Information System (INIS)

    Eibler, R.; Neckel, A.

    1975-01-01

    Results of Augmented Plane Wave (APW) band structure calculations are used to determine the magnetic susceptibilities of some transition metal monocarbides, mononitrides and monoxides (TiC, TiN, TiO, VC, VN, VO, NbC, NbN) assuming stoichiometric composition. Contributions to the susceptibility arising from the orbital para- and diamagnetism and the spin paramagnetism are determined separately. The orbital susceptibility terms are calculated by means of the model of Kubo and Obata. The calculated susceptibilities are compared with measured values. The approximations in the calculation of the orbital susceptibility terms are discussed especially with regard to the agreement between calculated and measured susceptibilities for the individual compounds. Similar calculations are performed for the susceptibilities of non-stoichiometric VCsub(x)-phase, for which APR-Virtual Crystal Approximation (VCA) band structure calculations are available. (author)

  12. Effects of continuous exposure to carbon monoxide on auditory vigilance in man

    Energy Technology Data Exchange (ETDEWEB)

    Davies, D.M.; Jolly, E.J.; Pethybridge, R.J.; Colquhoun, W.P.

    1981-02-01

    Six different groups of non-smoking young male subjcts were stutied separately for 18 consecutive days each in a closed controlled-environment human exposure chamber. Each group was subjected to a 5-day control period in fresh air followed successively by an 8-day period of continuous exposure to 50 ppm, 15 ppm or 0 ppm (controll) by volume of carbon monoxide (CO) in air, and a 5-day recovery period in fresh air. The subjects performed a 1-h auditory vigilance task every day at the same time of day in a fixed qualitative, quantitative, and temporal relationship with food intake, consumption of stimulating beverages, physical activity, and sleep. It was concluded that such CO exposure, involving the continuous carriage of carboxyhaemoglobin loads up to 70%, was without significant effect on auditory vigilance.

  13. Carbon monoxide gas sensing using zinc oxide deposited by successive ionic layer adhesion and reaction

    Science.gov (United States)

    Florido, E. A.; Dagaas, N. A. C.

    2017-05-01

    This study was aimed to determine the carbon monoxide (CO) gas sensing capability of zinc oxide (ZnO) film fabricated by successive ionic layer adsorption and reaction (SILAR) on glass substrate. Films consisting of a mixture of flower-like clusters of ZnO nanorods and nanowires were observed using scanning electron microscopy (SEM). Current-voltage characterization of the samples showed an average resistivity of 13.0 Ω-m. Carbon monoxide gas was synthesized by mixing the required amount of formic acid and excess sulfuric acid to produce CO gas concentrations of 100, 200, 300, 400, and 500 parts per million (ppm) v/v with five trials for each concentration. Two sets of data were obtained. One set consisted of the voltage response of the single film sensor while the other set were obtained from the double film sensor. The voltage response for the single film sensor and the double film sensor showed an average sensitivity of 0.0038 volts per ppm and 0.0024 volts per ppm, respectively. The concentration the single film can detect with a 2V output is 526 ppm while the double film sensor can detect up to 833 ppm with a 2V output. This shows that using the double film sensor is advantageous compared to single film sensor, because of its higher concentration range due to the larger surface area for the gas to interact. Moreover, the measured average resistance for the single film sensor was 10 MΩ while for the double film sensor the average resistance was 5 MΩ.

  14. Elevated carboxyhemoglobin: sources of carbon monoxide exposure.

    Science.gov (United States)

    Buchelli Ramirez, Herminia; Fernández Alvarez, Ramón; Rubinos Cuadrado, Gemma; Martinez Gonzalez, Cristina; Rodriguez Jerez, Francisco; Casan Clara, Pere

    2014-11-01

    Inhalation of carbon monoxide (CO) can result in poisoning, with symptoms ranging from mild and nonspecific to severe, or even death. CO poisoning is often underdiagnosed because exposure to low concentrations goes unnoticed, and threshold values for normal carboxyhemoglobin vary according to different authors. The aim of our study was to analyze carboxyhemoglobin (COHb) levels in an unselected population and detect sources of CO exposure In a cross-sectional descriptive study, we analyzed consecutive arterial blood gas levels processed in our laboratory. We selected those with COHb≥2.5% in nonsmokers and ≥5% in smokers. In these cases a structured telephone interview was conducted. Elevated levels of COHb were found in 64 (20%) of 306 initial determinations. Of these, data from 51 subjects aged 65±12 years, 31 (60%) of which were men, were obtained. Mean COHb was 4.0%. Forty patients (78%) were non-smokers with mean COHb of 3.2%, and 11 were smokers with COHb of 6.7%. In 45 patients (88.2%) we detected exposure to at least one source of ambient CO other than cigarette smoke. A significant proportion of individuals from an unselected sample had elevated levels of COHb. The main sources of CO exposure were probably the home, so this possibility should be explored. The population should be warned about the risks and encouraged to take preventive measures. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  15. Zinc-oxide nanorod / copper-oxide thin-film heterojunction for a nitrogen-monoxide gas sensor

    International Nuclear Information System (INIS)

    Yoo, Hwansu; Kim, Hyojin; Kim, Dojin

    2014-01-01

    A novel p - n oxide heterojunction structure was fabricated by employing n-type zinc-oxide (ZnO) nanorods grown on an indium-tin-oxide-coated glass substrate by using the hydrothermal method and a p-type copper-oxide (CuO) thin film deposited onto the ZnO nanorod array by using the sputtering method. The crystallinities and microstructures of the heterojunction materials were examined by using X-ray diffraction and scanning electron microscopy. The observed current - voltage characteristics of the p - n oxide heterojunction showed a nonlinear diode-like rectifying behavior. The effects of an oxidizing or electron acceptor gas, such as nitrogen monoxide (NO), on the ZnO nanorod/CuO thin-film heterojunction were investigated to determine the potential applications of the fabricated material for use in gas sensors. The forward current of the p - n heterojunction was remarkably reduced when NO gas was introduced into dry air at temperatures from 100 to 250 .deg. C. The NO gas response of the oxide heterojunction reached a maximum value at an operating temperature of 180 .deg. C and linearly increased as the NO gas concentration was increased from 5 to 30 ppm. The sensitivity value was observed to be as high as 170% at 180 .deg. C when biased at 2 V in the presence of 20-ppm NO. The ZnO nanorod/CuO thin-film heterojunction also exhibited a stable and repeatable response to NO gas. The experimental results suggest that the ZnO nanorod/CuO thin-film heterojunction structure may be a novel candidate for gas sensors.

  16. Zinc-oxide nanorod / copper-oxide thin-film heterojunction for a nitrogen-monoxide gas sensor

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hwansu; Kim, Hyojin; Kim, Dojin [Chungnam National University, Daejeon (Korea, Republic of)

    2014-11-15

    A novel p - n oxide heterojunction structure was fabricated by employing n-type zinc-oxide (ZnO) nanorods grown on an indium-tin-oxide-coated glass substrate by using the hydrothermal method and a p-type copper-oxide (CuO) thin film deposited onto the ZnO nanorod array by using the sputtering method. The crystallinities and microstructures of the heterojunction materials were examined by using X-ray diffraction and scanning electron microscopy. The observed current - voltage characteristics of the p - n oxide heterojunction showed a nonlinear diode-like rectifying behavior. The effects of an oxidizing or electron acceptor gas, such as nitrogen monoxide (NO), on the ZnO nanorod/CuO thin-film heterojunction were investigated to determine the potential applications of the fabricated material for use in gas sensors. The forward current of the p - n heterojunction was remarkably reduced when NO gas was introduced into dry air at temperatures from 100 to 250 .deg. C. The NO gas response of the oxide heterojunction reached a maximum value at an operating temperature of 180 .deg. C and linearly increased as the NO gas concentration was increased from 5 to 30 ppm. The sensitivity value was observed to be as high as 170% at 180 .deg. C when biased at 2 V in the presence of 20-ppm NO. The ZnO nanorod/CuO thin-film heterojunction also exhibited a stable and repeatable response to NO gas. The experimental results suggest that the ZnO nanorod/CuO thin-film heterojunction structure may be a novel candidate for gas sensors.

  17. Monitoring of carbon monoxide in residences with bulk wood pellet storage in the Northeast United States.

    Science.gov (United States)

    Rossner, Alan; Jordan, Carolyn E; Wake, Cameron; Soto-Garcia, Lydia

    2017-10-01

    The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure. This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations

  18. Magnetic resonance (MR) imaging in delayed encephalopathy of acute carbon monoxide poisoning - comparison with CT -

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Suh, Chang Hae; Choo, In Wook

    1986-01-01

    Eleven magnetic resonance (MR) and computed tomographic (CT) imaging were performed in nine patients with mild to moderate degree of delayed neuropsychiatric symptoms following acute carbon monoxide (CO) poisoning, to evaluate the capability of MR in demonstrating any additional finding to CT. The MR images were obtained using 0.15 Tesla resistive system with various combination of three pulse sequences, including partial saturation recovery, T2-weighted spin echo and inversion recovery. Bilateral white matter abnormalities suggesting demyelination were demonstrated in 4 patients with MR and in only 2 patients with CT. The contrast discrimination between normal and abnormal white matter proved to be better with T2-weighted spin echo and inversion recovery than with partial saturation recovery and CT. But necrosis of the globus pallidus (1 patient) and diffuse atrophy (3 patients) were equally demonstrated on both MR and CT. It is suggested that MR be used as a initial imaging method in the evaluation of the delayed encephalopathy following acute CO poisoning, especially for the detection of the possible white matter lesions. Acute carbon monoxide (CO) poisoning produces hypoxia by displacing oxygen from hemoglobin and preventing its release from hemoglobin in tissues, often resulting in fetal event. Victims who survive acute CO poisoning may have various delayed symptoms and signs. Occasionally, an apparent recovery is followed within two days to three weeks by a sudden neurological deterioration. The degree of neuropsychiatric symptoms depends upon the extent and severity of the pathologic changes in the brain. The pathologic effects of CO poisoning are present in almost all organs of patients. However, the most important changes occur in the brain, which consist of necrosis of the globus pallidus and reticular zone of the substantia nigra, and the degeneration of the cerebral white matter. The diagnostic superiority of magnetic resonance (MR) over CT has already

  19. Measurement of exhaled breath carbon monoxide in clinical practice: A study of levels in Central Pennsylvania community members.

    Science.gov (United States)

    Hrabovsky, Shari; Yingst, Jessica M; Veldheer, Susan; Hammett, Erin; Foulds, Jonathan

    2017-06-01

    Exhaled breath carbon monoxide (eBCO) reading is a useful tool for nurse practitioners to evaluate smoking status and other exposures to carbon monoxide (CO) to identify risk for cancer and chronic disease. This study aimed to measure one community's eBCO and identify potential environmental factors that may affect eBCO among nonsmokers. Data collected by convenience sampling at community health events included self-reported tobacco use and potential CO exposure. Means and frequency calculations describe the sample, two-sided t-tests determine differences in continuous variables, and chi-square tests determine differences in frequencies of CO levels between nontobacco users exposed to additional CO from their environment and nontobacco users who were not. As expected, smokers have significantly higher mean eBCO than nonsmokers (20.1 ppm vs. 4.4 ppm, p 6 ppm), although there were no environmental factors that explained a higher eBCO. Measuring eBCO provides an opportunity for the nurse practitioner to engage in a conversation about the impact of smoking and other environmental factors that contribute to eBCO and health. Keeping record of patients' smoking status and eBCO in their medical record is a valuable measure of the nurse practitioner's delivery of this care. ©2017 American Association of Nurse Practitioners.

  20. Study of Hopcalite (CuMnOx Catalysts Prepared Through A Novel Route for the Oxidation of Carbon Monoxide at Low Temperature

    Directory of Open Access Journals (Sweden)

    Subhashish Dey

    2017-10-01

    How to Cite: Dey, S., Dhal, G.C., Mohan, D., Prasad, R. (2017. Study of Hopcalite (CuMnOx Catalysts Prepared through A Novel Route for the Oxidation of Carbon Monoxide at Low Temperature. Bulletin of Chemical Reaction Engineering & Catalysis, 12 (3: 393-407 (doi:10.9767/bcrec.12.3.882.393-407

  1. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G. [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  2. Carbon monoxide column retrieval for clear-sky and cloudy atmospheres : A full-mission data set from SCIAMACHY 2.3 μm reflectance measurements

    NARCIS (Netherlands)

    Borsdorff, Tobias; De Brugh, Joost Aan; Hu, Haili; Nédélec, Philippe; Aben, Ilse; Landgraf, Jochen

    2017-01-01

    We discuss the retrieval of carbon monoxide (CO) vertical column densities from clear-sky and cloud contaminated 2311-2338 nm reflectance spectra measured by the Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY) from January 2003 until the end of the mission in April

  3. Effect of multi-walled carbon nanotubes aspect ratio and temperature on the dielectric behavior of alternating alkene-carbon monoxide polyketone nanocomposites

    Science.gov (United States)

    Abu-Surrah, Adnan S.; Abdul Jawad, Saadi; Al-Ramahi, Esraa; Hallak, Awni B.; Khattari, Z.

    2015-04-01

    New alternating poly(propylene-alt-carbon monoxide/ethylene-alt-carbon monoxide) (PECO)/multiwalled carbon nanotubes (MWCNTs) composites have been prepared. Dielectric permittivity, electric modulus and ac conductivity of the isolated materials were investigated as a function of fiber aspect ratio, frequency and temperature. For aspect ratio of 30 and 200, a transition from insulator to semiconductor was observed at frequency 1×104. However, for high aspect ratio sample (660), no transition was observed and the conductivity is frequency independent in the measured frequency range of 10-106 Hz. The conductivity increases from about 1×10-4 for the sample that contain fibers of aspect ratio 30 and reaches 5×10-2 (Ω m)-1 for aspect ratio was 660. This behavior can be modeled by a circuit that consists of a contact resistance in series with a parallel combination of resistance (R) and capacitance (C). The calculated activation energy for sample filled with fibers having aspect ratio 30 is about 0.26 eV and decreases to about 0.16 eV when the aspect ratio is 660.

  4. Monoxides of small terbium clusters: A density functional theory investigation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, G. L.; Yuan, H. K., E-mail: yhk10@swu.edu.cn; Chen, H.; Kuang, A. L.; Li, Y.; Wang, J. Z.; Chen, J. [School of Physical Science and Technology, Southwest University, Chongqing 400715 (China)

    2014-12-28

    To investigate the effect of oxygen atom on the geometrical structures, electronic, and magnetic properties of small terbium clusters, we carried out the first-principles calculations on Tb{sub n}O (n = 1-14) clusters. The capping of an oxygen atom on one trigonal-facet of Tb{sub n} structures is always favored energetically, which can significantly improve the structural stability. The far-infrared vibrational spectroscopies are found to be different from those of corresponding bare clusters, providing a distinct signal to detect the characteristic structures of Tb{sub n}O clusters. The primary effect of oxygen atom on magnetic properties is to change the magnetic orderings among Tb atoms and to reduce small of local magnetic moments of the O-coordinated Tb atoms, both of which serve as the key reasons for the experimental magnetic evolution of an oscillating behavior. These calculations are consistent with, and help to account for, the experimentally observed magnetic properties of monoxide Tb{sub n}O clusters [C. N. Van Dijk et al., J. Appl. Phys. 107, 09B526 (2010)].

  5. Solubility of carbon monoxide in bio-oil compounds

    International Nuclear Information System (INIS)

    Qureshi, Muhammad Saad; Le Nedelec, Tom; Guerrero-Amaya, Hernando; Uusi-Kyyny, Petri; Richon, Dominique; Alopaeus, Ville

    2017-01-01

    Highlights: • CO solubility was measured in four bio-oil compounds using static-analytic VLE equipment. • A comparison on the performance of different EoS (PC-SAFT, SRK and PR) was made. • Modelling of polar compounds with Polar PC-SAFT was tested. • Polar PC-SAFT is not needed for weakly polar compounds (μ < 1.0 D). - Abstract: The solubility of carbon monoxide is measured in four different bio-oil compounds (furan, diacetyl, 2-methylfuran, and trans-crotonaldehyde) at temperatures (273.15, 283.15, 298.15, and 323.15 K) and pressures up to 8 MPa using a static-analytical VLE measurement method. The equipment was validated by measuring the solubility of CO 2 in methanol at 298.15 K and pressures (P = 2.9–5.7 MPa). The results were compared with the abundantly available literature values. PC-SAFT, Polar PC-SAFT (PPC-SAFT), and Cubic (SRK, PR) EoS, part of commercial process simulator Aspen Plus V. 8.6, are used here for modelling purpose. The pure component parameters needed for PC-SAFT and PPC-SAFT EoS models, are regressed using the experimental liquid density and vapour pressure data of the pure components. It was observed that furan, 2-methylfuran and diacetyl, having weak dipole moments (μ < 1.0 D), could be modelled reasonably well without the addition of polar contribution using conventional PC-SAFT, while it is recommended to use PPC-SAFT for the description of a polar compound like trans-crotonaldehyde (μ ∼ 3.67 D). It was observed that SRK and PR EoS have similar predictive ability in comparison to PC-SAFT for a mixture of CO with weakly polar compounds in this study. A comparison between the performances of EoS models was made in two ways: first by setting the binary interaction parameter k ij to zero, and second by adjusting a temperature-dependent binary interaction parameter (k ij ). All the models perform with comparable accuracy with adjusted binary interaction parameters. However, due to the large differences between the chemical and

  6. Performance of a carbon monoxide sensor based on zirconia-doped ceria

    Directory of Open Access Journals (Sweden)

    Noriya Izu

    2016-06-01

    Full Text Available Resistive-type carbon monoxide sensors were fabricated using zirconia-doped ceria, and their sensing properties were evaluated and compared with equivalent devices based on non-doped ceria. The response of both sensor types was found to increase with decreasing temperature, while the response at 450 °C of a sensor fired at 950 °C was greater than that of a sensor fired at 1100 °C. When fired at 950 °C, however, the response at 450 °C of a sensor created using zirconia-doped ceria was slightly less than that of a sensor constructed from non-doped ceria. Multivariate analysis confirmed that the response of both sensor types is proportional to the resistance raised to the power of about 0.5, and inversely proportional to the particle size raised to a power of about 0.8. The sensor response time can be considered almost the same regardless of whether zirconia doping is used or not.

  7. Carbon monoxide poisoning and death in a large enclosed ventilated area.

    Science.gov (United States)

    Huston, Butch; Froloff, Victor; Mills, Kelly; McGee, Michael

    2013-11-01

    A 55-year-old man with a medical history of tobacco use suddenly collapsed while power washing an empty indoor pool in a hotel. The decedent was transported to the local hospital where he was pronounced. A postmortem examination revealed atherosclerotic heart disease and bilateral pulmonary edema and congestion. A postmortem blood carbon monoxide (CO) level was 27% saturation, and a CO performed on hospital admission blood was 49% saturation. CO poisoning is a common cause of toxicological morbidity and mortality in the United States. The circumstances most often occur in an enclosed environment and may be intentional or unintentional. CO poisoning has been reported in open, well-ventilated spaces, but rarely results in death. A warning label was present on the engine clearly stating the dangers of CO emission. However, there was a false sense of security due to the large size of the pool room and the presence of industrial blowers that were being used for ventilation. © 2013 American Academy of Forensic Sciences.

  8. A 40-year record of Northern Hemisphere atmospheric carbon monoxide concentration and isotope ratios from the firn at Greenland Summit.

    Science.gov (United States)

    Place, P., Jr.; Petrenko, V. V.; Vimont, I.; Buizert, C.; Lang, P. M.; Edwards, J.; Harth, C. M.; Hmiel, B.; Mak, J. E.; Novelli, P. C.; Brook, E.; Weiss, R. F.; Vaughn, B. H.; White, J. W. C.

    2014-12-01

    Carbon Monoxide (CO) is an important atmospheric trace gas that affects the oxidative capacity of the atmosphere and contributes indirectly to climate forcing by being a major sink of tropospheric OH. A good understanding of the past atmospheric CO budget is therefore important for climate models attempting to characterize recent changes in the atmosphere. Previous work at NEEM, Greenland provided the first reconstructions of Arctic atmospheric history of CO concentration and stable isotope ratios (δC18O and δ13CO) from firn air, dating to the 1950s. In this new study, firn air was sampled from eighteen depth levels through the firn column at Summit, Greenland (in May 2013), yielding a second, independent record of Arctic CO concentration and isotopic ratios. Carbon monoxide stable isotope ratios were analyzed on replicate samples and using a newly developed system with improved precision allowing for a more robust reconstruction. The new CO concentration and stable isotope results overall confirm the earlier findings from NEEM, with a CO concentration peak around the 1970s and higher δC18O and δ13CO values associated with peak CO. Modeling and interpretation of the data are in progress.

  9. Multiband carbon monoxide laser (2.5 -- 4.0 and 5.0 -- 6.5 micron) pumped by capacitive slab RF discharge

    Science.gov (United States)

    Ionin, Andrey; Kozlov, Andrey; Seleznev, Leonid; Sinitsyn, Dmitry

    2008-10-01

    Overtone lasing and fundamental band tuning was for the first time obtained in a carbon monoxide laser excited by repetitively pulsed capacitive slab RF discharge (81.36 MHz). RF discharge pulse repetition rate was 100--500 Hz. The active volume was 3x30x250 cubic mm. Laser electrodes were cooled down to 120 K. Gas mixture CO:air:He at gas pressure 15 Torr was used. The optical scheme ``frequency selective master oscillator - laser amplifier'' was applied for getting fundamental band tuning. Single line lasing with average power up to several tens of mW was observed on about 100 rotational-vibrational transitions of CO molecule within the spectral range 5.0--6.5 micron. Multiline overtone lasing was observed on about 80 spectral lines within the spectral range 2.5-4.0 micron, with maximum single line average output power 12 mW. The total output power of the slab overtone CO laser came up to 0.35 W, with laser efficiency 0.5 percent. The results of parametric studies of capacitive slab RF discharge in carbon monoxide mixtures, and overtone and fundamental band CO laser characteristics are discussed.

  10. Acute Carbon Monoxide Poisoning Resulting in ST Elevation Myocardial Infarction: A Rare Case Report

    Directory of Open Access Journals (Sweden)

    Po-Chao Hsu

    2010-05-01

    Full Text Available Acute carbon monoxide (CO poisoning with cardiac complications is well documented in the literature. However, ST segment elevation is a rare presentation, and most of these cases with ST elevation have revealed non-occlusive or normal coronary arteries. We report a case of CO poisoning complicated with ST elevation myocardial infarction. Emergency coronary angiography revealed total occlusion of the left anterior descending artery and primary percutaneous coronary intervention was performed. This report of a rare case should remind physicians that cardiovascular investigations, including electrocardiography, must be performed in cases with CO poisoning because mortality might increase if reperfusion therapy or appropriate medical treatments are not performed in patients with acute coronary artery occlusion.

  11. Determination of phospholipids in soybean lecithin samples via the phosphorus monoxide molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry.

    Science.gov (United States)

    Pires, Laís N; Brandão, Geovani C; Teixeira, Leonardo S G

    2017-06-15

    This paper presents a method for determining phospholipids in soybean lecithin samples by phosphorus determination using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) via molecular absorption of phosphorus monoxide. Samples were diluted in methyl isobutyl ketone. The best conditions were found to be 213.561nm with a pyrolysis temperature of 1300°C, a volatilization temperature of 2300°C and Mg as a chemical modifier. To increase the analytical sensitivity, measurement of the absorbance signal was obtained by summing molecular transition lines for PO surrounding 213nm: 213.561, 213.526, 213.617 and 213.637nm. The limit of detection was 2.35mgg -1 and the precision, evaluated as relative standard deviation (RSD), was 2.47% (n=10) for a sample containing 2.2% (w/v) phosphorus. The developed method was applied for the analysis of commercial samples of soybean lecithin. The determined concentrations of phospholipids in the samples varied between 38.1 and 45% (w/v). Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Heterologous Production of an Energy-Conserving Carbon Monoxide Dehydrogenase Complex in the Hyperthermophile Pyrococcus furiosus

    Directory of Open Access Journals (Sweden)

    Gerrit Jan Schut

    2016-01-01

    Full Text Available Carbon monoxide (CO is an important intermediate in anaerobic carbon fixation pathways in acetogenesis and methanogenesis. In addition, some anaerobes can utilize CO as an energy source. In the hyperthermophilic archaeon Thermococcus onnurineus, which grows optimally at 80°C, CO oxidation and energy conservation is accomplished by a respiratory complex encoded by a 16-gene cluster containing a carbon monoxide dehydrogenase, a membrane-bound [NiFe]-hydrogenase and a Na+/H+ antiporter module. This complex oxidizes CO, evolves CO2 and H2, and generates a Na+ motive force that is used to conserve energy by a Na+-dependent ATP synthase. Herein we used a bacterial artificial chromosome to insert the 13.2 kb gene cluster encoding the CO-oxidizing respiratory complex of T. onnurineus into the genome of the heterotrophic archaeon, Pyrococcus furiosus, which grows optimally at 100°C. P. furiosus is normally unable to utilize CO, however, the recombinant strain readily oxidized CO and generated H2 at 80°C. Moreover, CO also served as an energy source and allowed the P. furiosus strain to grow with a limiting concentration of sugar or with peptides as the carbon source. Moreover, CO oxidation by P. furiosus was also coupled to the re-utilization, presumably for biosynthesis, of acetate generated by fermentation. The functional transfer of CO utilization between Thermococcus and Pyrococcus species demonstrated herein is representative of the horizontal gene transfer of an environmentally-relevant metabolic capability. The transfer of CO utilizing, hydrogen-producing genetic modules also has applications for biohydrogen production and a CO-based industrial platform for various thermophilic organisms.

  13. Solar cycle variations in mesospheric carbon monoxide

    Science.gov (United States)

    Lee, Jae N.; Wu, Dong L.; Ruzmaikin, Alexander; Fontenla, Juan

    2018-05-01

    As an extension of Lee et al. (2013), solar cycle variation of carbon monoxide (CO) is analyzed with MLS observation, which covers more than thirteen years (2004-2017) including maximum of solar cycle 24. Being produced primarily by the carbon dioxide (CO2) photolysis in the lower thermosphere, the variations of the mesospheric CO concentration are largely driven by the solar cycle modulated ultraviolet (UV) variation. This solar signal extends down to the lower altitudes by the dynamical descent in the winter polar vortex, showing a time lag that is consistent with the average descent velocity. To characterize a global distribution of the solar impact, MLS CO is correlated with the SORCE measured total solar irradiance (TSI) and UV. As high as 0.8 in most of the polar mesosphere, the linear correlation coefficients between CO and UV/TSI are more robust than those found in the previous work. The photochemical contribution explains most (68%) of the total variance of CO while the dynamical contribution accounts for 21% of the total variance at upper mesosphere. The photochemistry driven CO anomaly signal is extended in the tropics by vertical mixing. The solar cycle signal in CO is further examined with the Whole Atmosphere Community Climate Model (WACCM) 3.5 simulation by implementing two different modeled Spectral Solar Irradiances (SSIs): SRPM 2012 and NRLSSI. The model simulations underestimate the mean CO amount and solar cycle variations of CO, by a factor of 3, compared to those obtained from MLS observation. Different inputs of the solar spectrum have small impacts on CO variation.

  14. Effects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Di Donato Michele

    2009-12-01

    Full Text Available Abstract Background High levels of exhaled carbon monoxide (eCO are a marker of airway or lung inflammation. We investigated whether hypo- or hyperventilation can affect measured values. Methods Ten healthy volunteers were trained to achieve sustained end-tidal CO2 (etCO2 concentrations of 30 (hyperventilation, 40 (normoventilation, and 50 mmHg (hypoventilation. As soon as target etCO2 values were achieved for 120 sec, exhaled breath was analyzed for eCO with a photoacoustic spectrometer. At etCO2 values of 30 and 40 mmHg exhaled breath was sampled both after a deep inspiration and after a normal one. All measurements were performed in two different environmental conditions: A ambient CO concentration = 0.8 ppm and B ambient CO concentration = 1.7 ppm. Results During normoventilation, eCO mean (standard deviation was 11.5 (0.8 ppm; it decreased to 10.3 (0.8 ppm during hyperventilation (p 2 changes (hyperventilation: 10% Vs 25% decrease; hypoventilation 3% Vs 25% increase. Taking a deep inspiration before breath sampling was associated with lower eCO values (p Conclusions eCO measurements should not be performed during marked acute hyperventilation, like that induced in this study, but the influence of less pronounced hyperventilation or of hypoventilation is probably negligible in clinical practice

  15. Relation of whole blood carboxyhemoglobin concentration to ambient carbon monoxide exposure estimated using regression.

    Science.gov (United States)

    Rudra, Carole B; Williams, Michelle A; Sheppard, Lianne; Koenig, Jane Q; Schiff, Melissa A; Frederick, Ihunnaya O; Dills, Russell

    2010-04-15

    Exposure to carbon monoxide (CO) and other ambient air pollutants is associated with adverse pregnancy outcomes. While there are several methods of estimating CO exposure, few have been evaluated against exposure biomarkers. The authors examined the relation between estimated CO exposure and blood carboxyhemoglobin concentration in 708 pregnant western Washington State women (1996-2004). Carboxyhemoglobin was measured in whole blood drawn around 13 weeks' gestation. CO exposure during the month of blood draw was estimated using a regression model containing predictor terms for year, month, street and population densities, and distance to the nearest major road. Year and month were the strongest predictors. Carboxyhemoglobin level was correlated with estimated CO exposure (rho = 0.22, 95% confidence interval (CI): 0.15, 0.29). After adjustment for covariates, each 10% increase in estimated exposure was associated with a 1.12% increase in median carboxyhemoglobin level (95% CI: 0.54, 1.69). This association remained after exclusion of 286 women who reported smoking or being exposed to secondhand smoke (rho = 0.24). In this subgroup, the median carboxyhemoglobin concentration increased 1.29% (95% CI: 0.67, 1.91) for each 10% increase in CO exposure. Monthly estimated CO exposure was moderately correlated with an exposure biomarker. These results support the validity of this regression model for estimating ambient CO exposures in this population and geographic setting.

  16. FTIR study of carbon monoxide adsorption on ion-exchanged X, Y and mordenite type zeolites

    Directory of Open Access Journals (Sweden)

    R. HERCIGONJA

    2003-05-01

    Full Text Available In this work Fourier transform infrared (FTIR study has been applied to study the adsorption of carbon monoxide on transition metal (Mn+, Co2+, Ni2+ ion-exchanged zeolites type Y, X and mordenites. The adsorption of CO at room temperature produces overlapping IR absorption bands in the 2120–2200 cm-1 region. The frequency of the band around 2200 cm-1 is found to be dependent not only on the charge-balancing transition metal cation, but also on the framework composition. The frequencies of the band near 1600 cm-1 was found to be dependent on the Si/Al ratio of the investigated zeolites.

  17. [A social history of carbon monoxide poisoning in Korea in 1960s: from an accident due to carelessness to a social disease].

    Science.gov (United States)

    Kim, Ock-Joo; Park, Se Hong

    2012-08-31

    This paper deals with social history of carbon monoxide poisoning in Korea in 1960s. From the mid 1950s, Korean society began to use coal briquettes (Yeontan) for fuel for cooking and heating in the winter, especially in urban area. As the use of coal briquettes replaced fire woods which had been used as fuel in traditional Korean society for centuries, incidence and deaths from carbon monoxide poisoning increased dramatically during the 1960s. The coal briquettes were used to heat the living rooms through "Ondol" arrangement. The coal briquettes at the kitchen place make the heated air and smoke, which pass through the horizontal space under a stone floor of the room and escape through chimney at the opposite site of the kitchen. This Ondol system could make leakage of carbon monoxide easily and thereby kill people who sleep in the room. In the 1960s, carbon monoxide poisoning by briquettes gas was a serious health problem to kill more people than all of the infectious diseases. It was a unique and very serious health hazard in 1960s Korea. No other place in the world has experienced such a high mortality and incidence from the briquettes gas as in Korea. Employing newspaper articles and epidemiological papers, this paper analyzes how the Korean society experienced and perceived carbon monoxide poisoning (CO poisoning) in 1960s. It also follows how the perception changed over time and how the changes affected social responses to CO poisoning. In the early 1960s, the CO poisoning was perceived as an accident due to carelessness of the people who did not fix the leakages of the Ondol system or that of the people who built the Ondol improperly. Mostly CO poisoning was the casualty caused by carelessness and ignorance of the poor class. The prevention measure was mainly education which would enlighten the ignorant so that they care about CO poisoning and their lives. It was the victims who were to be blamed, for they caused the their poisoning with their own

  18. CATALYSTS BASED ON UKRAINIAN NATURAL SORBENTS FOR LOW-TEMPERATURE CARBON MONOXIDE OXIDATION MEANT FOR INDIVIDUAL RESPIRATORY PROTECTIVE DEVICES

    Directory of Open Access Journals (Sweden)

    T. L. Rakyts’ka

    2015-11-01

    Full Text Available In spite of a great number of patented formulas of catalysts for neutralization of carbon monoxide (CO which is the most widespread atmospheric pollutant, only batch-produced hopcalite and alumina supported palladium (Pd/Al2O3 are used in practice. The named catalysts have significant defects: hopcalite is poisonable in the presence of water vapor and Pd/Al2O3 is characterized by the great content of palladium. We have found the possibility of using inexpensive Ukrainian natural sorbents differing by their mineralogical and chemical compositions, i.e. zeolites, bentonites, basalt tuffs, and disperse silicas, as supports for development and subsequent application of palladium(II and copper(II based catalysts for carbon monoxide oxidation. Acid-thermally modified Ukrainian sorbents have been found to be proper for obtaining supported copper-palladium complexes the most catalytically active in the reaction. Application of Ukrainian natural tripolis permitted to avoid the step of acid-thermal modification complicating the technique of catalyst production. As was found, the origin and phase composition of tripolis affect the activity of catalysts supported on them in the reaction of low-temperature Co oxidation. The most active catalyst permitting sanitary purification of air from CO to a level permissible for atmosphere of populated areas have been obtained in the case of insignificantly (thermally or hydrothermally modified tripoli from Konoplianskoe deposit.

  19. Gas-Phase Energetics of Actinide Oxides: An Assessment of Neutral and Cationic Monoxides and Dioxides from Thorium to Curium

    Science.gov (United States)

    Marçalo, Joaquim; Gibson, John K.

    2009-09-01

    An assessment of the gas-phase energetics of neutral and singly and doubly charged cationic actinide monoxides and dioxides of thorium, protactinium, uranium, neptunium, plutonium, americium, and curium is presented. A consistent set of metal-oxygen bond dissociation enthalpies, ionization energies, and enthalpies of formation, including new or revised values, is proposed, mainly based on recent experimental data and on correlations with the electronic energetics of the atoms or cations and with condensed-phase thermochemistry.

  20. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and a......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...

  1. Conversion of carbon dioxide to carbon monoxide by pulse dielectric barrier discharge plasma

    Science.gov (United States)

    Wang, Taobo; Liu, Hongxia; Xiong, Xiang; Feng, Xinxin

    2017-01-01

    The conversion of carbon dioxide (CO2) to carbon monoxide (CO) was investigated in a non-thermal plasma dielectric barrier discharge (DBD) reactor, and the effects of different process conditions on the CO2 conversion were investigated. The results showed that the increase of input power could optimize the conversion of CO2 to CO. The CO2 conversion and CO yield were negatively correlated with the gas flow rate, but there was an optimum gas flow rate, that made the CO selectivity best. The carrier gas (N2, Ar) was conducive to the conversion of CO2, and the effect of N2 as carrier gas was better than Ar. The conversion of CO2 to CO was enhanced by addition of the catalyst (5A molecular sieve).

  2. Post Hartree–Fock and DFT Studies on Pyrrole···Nitrogen and Pyrrole···Carbon Monoxide Molecules

    Directory of Open Access Journals (Sweden)

    P. Kolandaivel

    2002-07-01

    Full Text Available Abstract: The hydrogen bonded and van der Waals isomers of pyrrole···nitrogen and pyrrole···carbon monoxide have been studied using ab initio and density functional theory methods. Complex geometries and total energies of the isomers have been determined at HF, MP2, B3LYP and B3PW91 levels of theory employing 6-31G* basis set. For pyrrole···nitrogen complex, only two isomers have stable structure and the more stable one is found to be the hydrogen bonded isomer. Among the five isomers of pyrrole···carbon monoxide complex, the hydrogen bonded isomer is found to be the most stable form. The interaction energy for all these isomers have been calculated after eliminating the basis set superposition errors by using the full counterpoise correction method. Chemical hardness, chemical potential have been calculated and are used to study the stability of the molecules.

  3. Influence of carbon monoxide additions on the sensitivity of the dry hydrogen-air mixtures to detonation

    International Nuclear Information System (INIS)

    Magzumov, A.E.; Kirillov, I.A.; Fridman, A.A.; Rusanov, V.D.

    1995-01-01

    Under severe accident conditions of water cooled nuclear reactors the hydrogen-air detonation represents one of the most hazardous events which can result in the reactor containment damage. An important factor related with the measure of gas mixture detonability is the detonation cell size which correlates with the critical tube diameter and detonation initiation energy. A numerical kinetic study is presented of the influence of carbon monoxide admixtures (from 0 vol.% to 40 vol.%) upon the sensitivity (detonation cell size) of the dry hydrogen-air gas mixtures to detonation in post-accident containment atmosphere. (author). 3 refs., 3 figs

  4. Top-down estimate of a large source of atmospheric carbon monoxide associated with fuel combustion in Asia

    Energy Technology Data Exchange (ETDEWEB)

    Kasibhatla, P.; Arellano, A.; Logan, J.A.; Palmer, P.I.; Novelli, P. [Duke University, Durham, NC (United States). Nicholas School of Environmental & Earth Science

    2002-10-01

    Deriving robust regional estimates of the sources of chemically and radiatively important gases and aerosols to the atmosphere is challenging. Using an inverse modeling methodology, it was found that the source of carbon monoxide from fossil-fuel and biofuel combustion in Asia during 1994 was 350-380 Tg yr{sup -1}, which is 110-140 Tg yr{sup -1} higher than bottom-up estimates derived using traditional inventory-based approaches. This discrepancy points to an important gap in our understanding of the human impact on atmospheric chemical composition.

  5. Data sets used in the analysis presented in the manuscript “Regional and Hemispheric Influences on Temporal Variability in Baseline Carbon Monoxide and Ozone over the Northeast US”

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset documents that all of the data analyzed in the manuscript "Regional and Hemispheric Influences on Temporal Variability in Baseline Carbon Monoxide and...

  6. Onboard measurement system of atmospheric carbon monoxide over the Pacific Ocean by voluntary observing ships

    Science.gov (United States)

    Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.

    2011-07-01

    Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruising routes: from Japan to Oceania, from Japan to the United States, from Japan to Canada, and from Japan to Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards (CO balanced with purified air at ppmv levels) during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 yr. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.

  7. PFS/Mars Express first results: water vapour and carbon monoxide global distribution

    Science.gov (United States)

    Ignatiev, N. I.; Titov, D. V.; Formisano, V.; Moroz, V. I.; Lellouch, E.; Encrenaz, Th.; Fouchet, T.; Grassi, D.; Giuranna, M.; Atreya, S.; Pfs Team

    Planetary Fourier Spectrometer onboard Mars Express, with its wide spectral range (1.2--45 um) and high spectral resolution (1.4 cm-1), makes it possible to study in a self-consistent manner the Martian atmosphere by means of simultaneous analysis of spectral features in several spectral regions. As concerned small species, we observe 30--50, 6.3, 2.56, 1.87 and 1.38 μ m H2O bands, and 4.7 and 2.35 μ m CO bands. The most favourable, with respect to the instrument performance, 2.56 μ m H2O and 4.7 μ m CO bands, are used to study the variations of column abundance of water vapour and carbon monoxide on a global scale from pole to pole. All necessary atmospheric parameters, namely temperature profiles, surface pressure, and dust density are obtained from the same spectra, whenever possible.

  8. Heme oxygenase and carbon monoxide protect from muscle dystrophy.

    Science.gov (United States)

    Chan, Mun Chun; Ziegler, Olivia; Liu, Laura; Rowe, Glenn C; Das, Saumya; Otterbein, Leo E; Arany, Zoltan

    2016-11-28

    Duchenne muscle dystrophy (DMD) is one of the most common lethal genetic diseases of children worldwide and is 100% fatal. Steroids, the only therapy currently available, are marred by poor efficacy and a high side-effect profile. New therapeutic approaches are urgently needed. Here, we leverage PGC-1α, a powerful transcriptional coactivator known to protect against dystrophy in the mdx murine model of DMD, to search for novel mechanisms of protection against dystrophy. We identify heme oxygenase-1 (HO-1) as a potential novel target for the treatment of DMD. Expression of HO-1 is blunted in the muscles from the mdx murine model of DMD, and further reduction of HO-1 by genetic haploinsufficiency worsens muscle damage in mdx mice. Conversely, induction of HO-1 pharmacologically protects against muscle damage. Mechanistically, HO-1 degrades heme into biliverdin, releasing in the process ferrous iron and carbon monoxide (CO). We show that exposure to a safe low dose of CO protects against muscle damage in mdx mice, as does pharmacological treatment with CO-releasing molecules. These data identify HO-1 and CO as novel therapeutic agents for the treatment of DMD. Safety profiles and clinical testing of inhaled CO already exist, underscoring the translational potential of these observations.

  9. Gene expression in rat striatum following carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Shuichi Hara

    2017-06-01

    Full Text Available Carbon monoxide (CO poisoning causes brain damage, which is attenuated by treatment with hydrogen [1,2], a scavenger selective to hydroxyl radical (·≡OH [3]. This suggests a role of ·≡OH in brain damage due to CO poisoning. Studies have shown strong enhancement of ·≡OH production in rat striatum by severe CO poisoning with a blood carboxyhemoglobin (COHb level >70% due to 3000 ppm CO, but not less severe CO poisoning with a blood COHb level at approximately 50% due to 1000 ppm CO [4]. Interestingly, 5% O2 causes hypoxia comparable with that by 3000 ppm CO and produces much less •OH than 3000 ppm CO does [4]. In addition, cAMP production in parallel with ·≡OH production [5] might contribute to ·≡OH production [6]. It is likely that mechanisms other than hypoxia contribute to brain damage due to CO poisoning [7]. To search for the mechanisms, we examined the effects of 1000 ppm CO, 3000 ppm CO and 5% O2 on gene expression in rat striatum. All array data have been deposited in the Gene Expression Omnibus (GEO database under accession number GSE94780.

  10. EPIDEMIOLOGY OF CARBON MONOXIDE POISONING IN LJUBLJANA FROM 1990 TO 1999

    Directory of Open Access Journals (Sweden)

    Miran Brvar

    2002-02-01

    Full Text Available Background. Carbon monoxide (CO is the most common lethal poisoning. The incidence of sublethal CO poisoning in Slovenia is not known. The aim of the study was to investigate the epidemiology of sublethal acute CO poisoning in Ljubljana region (Slovenia.Methods. A retrospective study involved CO poisoned patients admited to Poison Control Centre and Centre of Intensive Care Medicine of the University Medical Centre Ljubljana, between January 1, 1990 and December 31, 1999.Results. There were annualy approximately 2.4 cases of sublethal CO poisonings per 100.000 population in Ljubljana region. Of these, 25% were suicide attempts and 75% were unintentional poisonings (28% happened in domestic environment as a result of heating, cooking or bathing, 22% were associated with fire, 11% happened in the working site, 10% happened in the workroom at home and only 3% occurred in the moving vehicle. Among the patients there were 72% male and 28% female. The domestic source of CO was a gas water heater or residential heating device in the 63% of the cases, a coal stove in the 32% and an oil heater in the 6%. In the 18% of the suicide attempts we found also acute drug or alcohol intoxication, and 18% of patients poisoned in the fire were intoxicated with alcohol. Collective poisoning happened in the 25% of cases affecting from 2 to 6 persons.Conclusions. The incidence of sublethal CO poisoning in Ljubljana region appers to be seven times lower than in other countries. The main reason is misdiagnosing of CO poisoning. In the future we should consider CO poisoning more often, particularly in all patients with flu-like symptoms, unexplained headache and worsening of pre-existing diseases. We should always exclude the collective poisoning and the presence of alcohol or other drugs.

  11. Titanium monoxide spectroscopy following laser-induced optical breakdown

    International Nuclear Information System (INIS)

    Parigger, Christian G.; Woods, Alexander C.; Keszler, Anna; Nemes, László; Hornkohl, James O.

    2012-01-01

    This work investigates Titanium Monoxide (TiO) in ablation-plasma by employing laser-induced breakdown spectroscopy (LIBS) with 1 to 10 TW/cm 2 irradiance, pulsed, 13 nanosecond, Q-switched Nd:YAG laser radiation at the fundamental wavelength of 1064 nm. The analysis of TiO is based on our first accurate determination of transition line strengths for selected TiO A-X, B-X, and E-X transitions, particularly TiO A-X γ and B-X γ′ bands. Electric dipole line strengths for the A 3 Φ-X 3 δ and B 3 Π-X 3 δ bands of TiO are computed. The molecular TiO spectra are observed subsequent to laser-induced breakdown (LIB). We discuss analysis of diatomic molecular spectra that may occur simultaneously with spectra originating from atomic species. Gated detection is applied to investigate the development in time of the emission spectra following LIB. Collected emission spectra allow one to infer micro-plasma parameters such as temperature and electron density. Insight into the state of the micro-plasma is gained by comparing measurements with predictions of atomic and molecular spectra. Nonlinear fitting of recorded and computed diatomic spectra provides the basis for molecular diagnostics, while atomic species may overlap and are simultaneously identified. Molecular diagnostic approaches similar to TiO have been performed for diatomic molecules such as AlO, C 2 , CN, CH, N 2 , NH, NO and OH.

  12. Carbon monoxide poisoning at motels, hotels, and resorts.

    Science.gov (United States)

    Weaver, Lindell K; Deru, Kayla

    2007-07-01

    Each year, more than 200 people in the United States die from carbon monoxide (CO) poisoning. Poisoning has occurred at motels, hotels, and resorts. Congressional mandate requires smoke alarms in all guest rooms; however, smoke alarms do not detect CO. Data on patients poisoned at hotels, motels, and resorts were evaluated at a hyperbaric medicine service. In 2005, legal databases and online news databanks were searched to discover additional incidents. Only victims evaluated in hospitals or declared dead at the scene were included. Cases of intentional poisoning and poisoning from fires were excluded. Between 1989 and 2004, 68 incidents of CO poisoning occurring at hotels, motels, and resorts were identified, resulting in 772 accidentally poisoned: 711 guests, 41 employees or owners, and 20 rescue personnel. Of those poisoned, 27 died, 66 had confirmed sequelae, and 6 had sequelae resulting in a jury verdict. Lodging-operated, faulty room heating caused 45 incidents, pool/spa boilers 16, CO entrained from outdoors 5, and unreported sources caused 2 incidents. Public verdicts have averaged $4.8 million per incident (range, $1 million to $17.5 million). Poisoning occurred at hotels of all classes. Despite these incidents, most properties did not install CO alarms, and requirements for CO alarms at hotels, motels, and resorts are rare. Guests of motels, hotels, and resorts remain at risk for injury or death from CO poisoning. Measures to prevent CO poisoning of guests and employees of the lodging industry should be evaluated.

  13. Carbon monoxide: from toxin to endogenous modulator of cardiovascular functions

    Directory of Open Access Journals (Sweden)

    R.A. Johnson

    1999-01-01

    Full Text Available Carbon monoxide (CO is a pollutant commonly recognized for its toxicological attributes, including CNS and cardiovascular effects. But CO is also formed endogenously in mammalian tissues. Endogenously formed CO normally arises from heme degradation in a reaction catalyzed by heme oxygenase. While inhibitors of endogenous CO production can raise arterial pressure, heme loading can enhance CO production and lead to vasodepression. Both central and peripheral tissues possess heme oxygenases and generate CO from heme, but the inability of heme substrate to cross the blood brain barrier suggests the CNS heme-heme oxygenase-CO system may be independent of the periphery. In the CNS, CO apparently acts in the nucleus tractus solitarii (NTS promoting changes in glutamatergic neurotransmission and lowering blood pressure. At the periphery, the heme-heme oxygenase-CO system can affect cardiovascular functions in a two-fold manner; specifically: 1 heme-derived CO generated within vascular smooth muscle (VSM can promote vasodilation, but 2 its actions on the endothelium apparently can promote vasoconstriction. Thus, it seems reasonable that the CNS-, VSM- and endothelial-dependent actions of the heme-heme oxygenase-CO system may all affect cardiac output and vascular resistance, and subsequently blood pressure.

  14. Experimental and clinical study of chronic poisoning by carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Thiele, H.; Gohlke, R.; Rothe, R.

    1973-01-01

    Animal and clinical tests on carbon monoxide-exposed subjects are described in an attempt to demonstrate the specific chronic action of CO. Rabbits exposed to 802 ppM and 284 ppM CO for 103 and 112 days, respectively, for 5 days a week showed carboxyhemoglobin values in the respective ranges of 2.5 to 11.9% and 2.5 to 8.3%. The macroscopic findings and gain in weight were normal, except for an increase by 20% and 14% in the weight of the liver. Dose-dependent increases in the hemoglobin and hematocrit levels, significant increases in the pyruvate level of the first group, and significant reductions of the cholinesterase, inorganic phosphate levels, hepatic lipase, phosphate, phosphatase, and cytochrome-C oxidase were observed. An increased cholinesterase level was found in brain homogenates. Inhibition of the glucose-6-phosphatase was observed. There is a specific damage due to CO in addition to merely the hypoxic effect. Clinical tests in humans with and without acute, subacute, or chronic exposure to CO revealed that acute and subacute poisoning have no additional pathogenic effect in chronic exposure, i.e., indicate the existence of primary chronic poisoning with CO.

  15. Carbon monoxide oxidation over three different states of copper: Development of a model metal oxide catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Jernigan, Glenn Geoffrey [California Univ., Berkeley, CA (United States). Dept. of Chemistry

    1994-10-01

    Carbon monoxide oxidation was performed over the three different oxidation states of copper -- metallic (Cu), copper (I) oxide (Cu2O), and copper (II) oxide (CuO) as a test case for developing a model metal oxide catalyst amenable to study by the methods of modern surface science and catalysis. Copper was deposited and oxidized on oxidized supports of aluminum, silicon, molybdenum, tantalum, stainless steel, and iron as well as on graphite. The catalytic activity was found to decrease with increasing oxidation state (Cu > Cu2O > CuO) and the activation energy increased with increasing oxidation state (Cu, 9 kcal/mol < Cu2O, 14 kcal/mol < CuO, 17 kcal/mol). Reaction mechanisms were determined for the different oxidation states. Lastly, NO reduction by CO was studied. A Cu and CuO catalyst were exposed to an equal mixture of CO and NO at 300--350 C to observe the production of N2 and CO2. At the end of each reaction, the catalyst was found to be Cu2O. There is a need to study the kinetics of this reaction over the different oxidation states of copper.

  16. Diode laser heterodyne observations of silicon monoxide in sunspots - A test of three sunspot models

    Science.gov (United States)

    Glenar, D. A.; Deming, D.; Jennings, D. E.; Kostiuk, T.; Mumma, M. J.

    1983-01-01

    Absorption features from the 8 micron SiO fundamental (upsilon = 1-0) and hot bands (upsilon = 2-1) have been observed in sunspots at sub-Doppler resolution using a ground-based tunable diode laser heterodyne spectrometer. The observed line widths suggest an upper limit of 0.5 km/s for the microturbulent velocity in sunspot umbrae. Since the silicon monoxide abundance is very sensitive to sunspot temperature, the measured equivalent widths permit an unambiguous determination of the temperature-pressure relation in the upper layers of the umbral atmosphere. In the region of SiO line formation (log P sub g = 3.0-4.5), the results support the sunspot model suggested by Stellmacher and Wiehr (1970).

  17. On Estimation of Contamination from Hydrogen Cyanide in Carbon Monoxide Line-intensity Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Dongwoo T.; Li, Tony Y.; Viero, Marco P.; Church, Sarah E.; Wechsler, Risa H., E-mail: dongwooc@stanford.edu [Kavli Institute for Particle Astrophysics and Cosmology, Physics Department, Stanford University, Stanford, CA 94305 (United States)

    2017-09-01

    Line-intensity mapping surveys probe large-scale structure through spatial variations in molecular line emission from a population of unresolved cosmological sources. Future such surveys of carbon monoxide line emission, specifically the CO(1-0) line, face potential contamination from a disjointed population of sources emitting in a hydrogen cyanide emission line, HCN(1-0). This paper explores the potential range of the strength of HCN emission and its effect on the CO auto power spectrum, using simulations with an empirical model of the CO/HCN–halo connection. We find that effects on the observed CO power spectrum depend on modeling assumptions but are very small for our fiducial model, which is based on current understanding of the galaxy–halo connection. Given the fiducial model, we expect the bias in overall CO detection significance due to HCN to be less than 1%.

  18. Experimental Spectroscopic Studies of Carbon Monoxide (CO) Fluorescence at High Temperatures and Pressures.

    Science.gov (United States)

    Carrivain, Olivier; Orain, Mikael; Dorval, Nelly; Morin, Celine; Legros, Guillaume

    2017-10-01

    Two-photon excitation laser-induced fluorescence of carbon monoxide (CO-LIF) is investigated experimentally in order to determine the applicability of this technique for imaging CO concentration in aeronautical combustors. Experiments are carried out in a high temperature, high-pressure test cell, and in a laminar premixed CH 4 /air flame. Influence of temperature and pressure on CO-LIF spectra intensity and shape is reported. The experimental results show that as pressure increases, the CO-LIF excitation spectrum becomes asymmetric. Additionally, the spectrum strongly shifts to the red with a quadratic dependence of the collisional shift upon pressure, which is different from the classical behavior where the collisional shift is proportional to pressure. Moreover, pressure line broadening cannot be reproduced by a Lorenztian profile in the temperature range investigated here (300-1750 K) and, therefore, an alternative line shape is suggested.

  19. Study of the reduction of sulfur dioxide to elemental sulfur by carbon monoxide on a La/sub 0/ /sub 5/ Sr/sub 0/ /sub 5/ CoO/sub 3/ catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Hibbert, D B; Tseung, A C.C.

    1979-12-01

    A study of the reduction of sulfur dioxide to elemental sulfur by carbon monoxide on a La/sub 0/ /sub 5/ Sr/sub 0/ /sub 5/ CoO/sub 3/ catalyst a perovskite oxide, to determine the effects of oxygen and water on SO2 reduction showed that in the presence of 5 to 16% oxygen, the reaction between sulfur dioxide and carbon monoxide still occurred if there was sufficient carbon monoxide in the gas to react with all the oxygen. At 600C, all the sulfur dioxide was removed at 5 to 16% oxygen levels. Water vapor at 2% did not adversely affect the reaction. The unwanted by-products, hydrogen disulfide and carbonyl sulfide, were reduced at contact times below 0.25 sec. During the reaction, the catalyst itself reacted with sulfur to give metal sulfides. When reagent grade CO/sub 2/O/sub 3/ was substituted for perovskite oxide, the maximum conversion of 98% of sulfur dioxide was attained at 550C, but an unacceptably high concentration of carbonyl sulfide was formed; within 1 hr, the sulfur dioxide conversion fell to 60%. The perovskite oxide reaction may be useful in removing sulfur dioxide from fosill fuel stack gases.

  20. Carbon Monoxide Emission and Concentration Models for Chiang Mai Urban Area

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    An emission inventory containing emissions from traffic and other sources was complied. Based on the analysis, Carbon Monoxide (CO) emissions from traffic play a very important role in CO levels in Chiang Mai area. Analysis showed that CO emissions from traffic during rush hours contributed approximately 90% of total CO emissions. Regional Atmospheric Modeling System (RAMS) was applied to simulate wind fields and temperatures in the Chiang Mai area, and eight cases were selected to study annual variations in wind fields and temperatures. Model results can reflect major features of wind fields and diurnal variations in temperatures. For evaluating the model performance, model results were compared with observed wind speed, wind direction and temperature, which were monitored at a meteorological tower. Comparison showed that model results are in good agreement with observations, and the model captured many of the observed features. HYbrid Particle And Concentration Transport model (HYPACT) was used to simulate CO concentration in the Chiang Mai area. Model results generally agree well with observed CO concentrations at the air quality monitoring stations, and can explain observed CO diurnal variations.

  1. Hypocapnia and cerebral hypoperfusion in orthostatic intolerance

    Science.gov (United States)

    Novak, V.; Spies, J. M.; Novak, P.; McPhee, B. R.; Rummans, T. A.; Low, P. A.

    1998-01-01

    BACKGROUND AND PURPOSE: Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). METHODS: Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. RESULTS: The OI group had higher supine heart rates (Pfailed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (Pindices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. CONCLUSIONS: Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

  2. Computational and variable-temperature infrared spectroscopic studies on carbon monoxide adsorption on zeolite Ca-A.

    Science.gov (United States)

    Pulido, Angeles; Nachtigall, Petr; Rodríguez Delgado, Montserrat; Otero Areán, Carlos

    2009-05-11

    Carbon monoxide adsorption on LTA (Linde type 5A) zeolite Ca-A is studied by using a combination of variable-temperature infrared spectroscopy and computational methods involving periodic density functional calculations and the correlation between stretching frequency and bond length of adsorbed CO species (nu(CO)/r(CO) correlation). Based on the agreement between calculated and experimental results, the main adsorption species can be identified as bridged Ca(2+)...CO...Ca(2+) complexes formed on dual-cation sites constituted by a pair of nearby Ca(2+) cations. Two types of such species can be formed: One of them has the two Ca(2+) ions located on six-membered rings of the zeolite framework and is characterized by a C-O stretching frequency in the range of 2174-2179 cm(-1) and an adsorption enthalpy of -31 to -33 kJ mol(-1), whereas the other bridged CO species is formed between a Ca(2+) ion located on an eight-membered ring and another one on a nearby six-membered ring and is characterized by nu(CO) in the range 2183-2188 cm(-1) and an adsorption enthalpy of -46 to -50 kJ mol(-1). Ca(2+)...CO monocarbonyl complexes are also identified, and at a relatively high CO equilibrium pressure, dicarbonyl species can also be formed.

  3. Response of Hepatoma 9618a and Normal Liver to Host Carbogen and Carbon Monoxide Breathing

    Directory of Open Access Journals (Sweden)

    Simon P. Robinson

    1999-12-01

    Full Text Available The effects of hyperoxia (induced by host carbogen 95% oxygen/5% carbon dioxide breathing. and hypoxia (induced by host carbon monoxide CO at 660 ppm. breathing were compared by using noninvasive magnetic resonance (MR methods to gain simultaneous information on blood flow/oxygenation and the bioenergetic status of rat Morris H9618a hepatomas. Both carbogen and CO breathing induced a 1.5- to 2-fold increase in signal intensity in blood oxygenation level dependent (BOLD MR images. This was due to a decrease in deoxyhemoglobin (deoxyHb, which acts as an endogenous contrast agent, caused either by formation of oxyhemoglobin in the case of carbogen breathing, or carboxyhemoglobin with CO breathing. The results were confirmed by observation of similar changes in deoxyHb in arterial blood samples examined ex vivo after carbogen or CO breathing. There was no change in nucleoside triphosphates (NTP/PI in either tumor or liver after CO breathing, whereas NTP/Pl increased twofold in the hepatoma (but not in the liver after carbogen breathing. No changes in tumor intracellular pH were seen after either treatment, whereas extracellular pH became more alkaline after CO breathing and more acid after carbogen breathing, respectively. This tumor type and the liver are unaffected by CO breathing at 660 ppm, which implies an adequate oxygen supply.

  4. Acceleration of spontaneous intimal-subintimal changes in rabbit aorta by a prolonged moderate carbon monoxide exposure

    Energy Technology Data Exchange (ETDEWEB)

    Wanstrup, J; Kjeldsen, K; Astrup, P

    1969-01-01

    Rabbits were exposed to 90 ppM CO by volume (11% COHb) for 3 months. More exposed animals had areas in the heart with hyperemia and/or hemorrhages, a greater degree of fibrous plaque formation on the aorta, and definitely more intimal-subintimal changes, including focal subintimal edema, endothelial cellular proliferation and breakdown, splitting up of subintimal fibrils, and collagen formation. There were no macroscopic differences, except abnomal amounts of fluid in serous cavity in experimental animals indicating increased endothelial membrane permeability. Tissue hypoxia (carbon monoxide exposure) seems to play a basic role in the development of focal vascular changes of the atherosclerotic type.

  5. Extension of an assessment model of ship traffic exhaust emissions for particulate matter and carbon monoxide

    Directory of Open Access Journals (Sweden)

    J.-P. Jalkanen

    2012-03-01

    Full Text Available A method is presented for the evaluation of the exhaust emissions of marine traffic, based on the messages provided by the Automatic Identification System (AIS, which enable the positioning of ship emissions with a high spatial resolution (typically a few tens of metres. The model also takes into account the detailed technical data of each individual vessel. The previously developed model was applicable for evaluating the emissions of NOx, SOx and CO2. This paper addresses a substantial extension of the modelling system, to allow also for the mass-based emissions of particulate matter (PM and carbon monoxide (CO. The presented Ship Traffic Emissions Assessment Model (STEAM2 allows for the influences of accurate travel routes and ship speed, engine load, fuel sulphur content, multiengine setups, abatement methods and waves. We address in particular the modeling of the influence on the emissions of both engine load and the sulphur content of the fuel. The presented methodology can be used to evaluate the total PM emissions, and those of organic carbon, elemental carbon, ash and hydrated sulphate. We have evaluated the performance of the extended model against available experimental data on engine power, fuel consumption and the composition-resolved emissions of PM. We have also compared the annually averaged emission values with those of the corresponding EMEP inventory, As example results, the geographical distributions of the emissions of PM and CO are presented for the marine regions of the Baltic Sea surrounding the Danish Straits.

  6. Validation of six years of SCIAMACHY carbon monoxide observations using MOZAIC CO profile measurements

    Directory of Open Access Journals (Sweden)

    A. T. J. de Laat

    2012-09-01

    Full Text Available This paper presents a validation study of SCanning Imaging Absorption SpectroMeter for Atmospheric CartograpHY (SCIAMACHY carbon monoxide (CO total column measurements from the Iterative Maximum Likelihood Method (IMLM algorithm using vertically integrated profile aircraft measurements obtained within the MOZAIC project for the six year time period of 2003–2008.

    Overall we find a good agreement between SCIAMACHY and airborne measurements for both mean values – also on a year-to-year basis – as well as seasonal variations. Several locations show large biases that are attributed to local effects like orography and proximity of large emission sources. Differences were detected for individual years: 2003, 2004 and 2006 have larger biases than 2005, 2007 and 2008, which appear to be related to SCIAMACHY instrumental issues but require more research. Results from this study are consistent with, and complementary to, findings from a previous validation study using ground-based measurements (de Laat et al., 2010b. According to this study, the SCIAMACHY data, if individual measurements are of sufficient quality – good signal-to-noise, can be used to determine the spatial distribution and seasonal cycles of CO total columns over clean areas. Biases found over areas with strong emissions (Africa, China could be explained by low sensitivity of the instrument in the boundary layer and users are recommended to avoid using the SCIAMACHY data while trying to quantify CO burden and/or retrieve CO emissions in such areas.

  7. Colonic insufflation with carbon monoxide gas inhibits the development of intestinal inflammation in rats

    Directory of Open Access Journals (Sweden)

    Takagi Tomohisa

    2012-09-01

    Full Text Available Abstract Background The pathogenesis of inflammatory bowel disease (IBD is complex, and an effective therapeutic strategy has yet to be established. Recently, carbon monoxide (CO has been reported to be capable of reducing inflammation by multiple mechanisms. In this study, we evaluated the role of colonic CO insufflation in acute colitis induced by trinitrobenzene sulfonic acid (TNBS in rats. Methods Acute colitis was induced with TNBS in male Wistar rats. Following TNBS administration, the animals were treated daily with 200 ppm of intrarectal CO gas. The distal colon was removed to evaluate various parameters of inflammation, including thiobarbituric acid (TBA-reactive substances, tissue-associated myeloperoxidase (MPO activity, and the expression of cytokine-induced neutrophil chemoattractant (CINC-1 in colonic mucosa 7 days after TNBS administration. Results The administration of TNBS induced ulceration with surrounding edematous swelling in the colon. In rats treated with CO gas, the colonic ulcer area was smaller than that of air-treated rats 7 days after TNBS administration. The wet colon weight was significantly increased in the TNBS-induced colitis group, which was markedly abrogated by colonic insufflation with CO gas. The increase of MPO activity, TBA-reactive substances, and CINC-1 expression in colonic mucosa were also significantly inhibited by colonic insufflation with CO gas. Conclusions Colonic insufflation with CO gas significantly ameliorated TNBS-induced colitis in rats. Clinical application of CO gas to improve colonic inflammatory conditions such as IBD might be useful.

  8. Progress in the reduction of carbon monoxide levels in major urban areas in Korea

    International Nuclear Information System (INIS)

    Kim, Ki-Hyun; Sul, Kyung-Hwa; Szulejko, Jan E.; Chambers, Scott D.; Feng, Xinbin; Lee, Min-Hee

    2015-01-01

    Long-term trends in observed carbon monoxide (CO) concentrations were analyzed in seven major South Korean cities from 1989 to 2013. Temporal trends were evident on seasonal and annual timescales, as were spatial gradients between the cities. As CO levels in the most polluted cities decreased significantly until the early 2000s, the data were arbitrarily divided into two time periods (I: 1989–2000 and II: 2001–2013) for analysis. The mean CO concentration of period II was about 50% lower than that of period I. Long-term trends of annual mean CO concentrations, examined using the Mann–Kendall (MK) method, confirm a consistent reduction in CO levels from 1989 to 2000 (period I). The abrupt reduction in CO levels was attributed to a combination of technological improvements and government administrative/regulatory initiatives (e.g., emission mitigation strategies and a gradual shift in the fuel/energy consumption mix away from coal and oil to natural gas and nuclear power). - Highlights: • As one of the criteria pollutants, CO has been extensively studied worldwide. • The concentration of CO in ambient air should be reduced to a more manageable level. • The spatiotemporal characteristics of CO in Korea are analyzed for 1989–2013. • Our efforts will help develop systematic strategies to reduce CO emissions. - The efficacy of CO mitigation strategies adopted throughout Korea is highlighted along with the limitations faced to improving air quality due to cross-boundary pollution transport.

  9. Effect of hyperbaric oxygen therapy on whole blood cyanide concentrations in carbon monoxide intoxicated patients from fire accidents

    DEFF Research Database (Denmark)

    Lawson-Smith, Pia; Jansen, Erik C; Hilsted, Linda

    2010-01-01

    Hydrogen cyanide (HCN) and carbon monoxide (CO) may be important components of smoke from fire accidents. Accordingly, patients admitted to hospital from fire accidents may have been exposed to both HCN and CO. Cyanide (CN) intoxication results in cytotoxic hypoxia leading to organ dysfunction...... and possibly death. While several reports support the use of hyperbaric oxygen therapy (HBO) for the treatment of severe CO poisoning, limited data exist on the effect of HBO during CN poisoning. HBO increases the elimination rate of CO haemoglobin in proportion to the increased oxygen partial pressure...

  10. Achievement report for fiscal 1998 on the preceding research related to global environment industry technologies. Survey and research on reduction of nitrogen monoxide; 1998 nendo chikyu sangyo gijutsu ni kakawaru sendo kenkyu asanka chisso no haishutsu teigen ni kansuru chosa kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Nitrogen monoxide is a strong greenhouse effect gas having warming up index per molecule 300 times greater than that of CO2, and is designated as the object of reduction in the Kyoto Conference. The present preceding research discusses necessity of performing research and development works related to reducing the emission of nitrogen monoxide, and if it is necessary, places the final objective on proposition of what researches should be planned. Fiscal 1997 being the first fiscal year of the preceding research has surveyed emission amount from different emission sources, and enumerated the research and development assignments. Fiscal 1998 falling under the final fiscal year summarizes the emission amount including the future trends, surveys the feasibility of the promising technological measures through experiments, and proposed finally a research and development plan desired of implementation in the future. The proposal contains a research plan placing development of nitrogen monoxide decomposing catalysts and automobile catalysts as the main objectives. Among the domestic nitrogen monoxide generating sources, about 2/3 is the man-made generation sources, hence catalysts, if developed, may be applied to such facilities as combustion furnaces. (NEDO)

  11. An open-terrain line source model coupled with street-canyon effects to forecast carbon monoxide at traffic roundabout.

    Science.gov (United States)

    Pandian, Suresh; Gokhale, Sharad; Ghoshal, Aloke Kumar

    2011-02-15

    A double-lane four-arm roundabout, where traffic movement is continuous in opposite directions and at different speeds, produces a zone responsible for recirculation of emissions within a road section creating canyon-type effect. In this zone, an effect of thermally induced turbulence together with vehicle wake dominates over wind driven turbulence causing pollutant emission to flow within, resulting into more or less equal amount of pollutants upwind and downwind particularly during low winds. Beyond this region, however, the effect of winds becomes stronger, causing downwind movement of pollutants. Pollutant dispersion caused by such phenomenon cannot be described accurately by open-terrain line source model alone. This is demonstrated by estimating one-minute average carbon monoxide concentration by coupling an open-terrain line source model with a street canyon model which captures the combine effect to describe the dispersion at non-signalized roundabout. The results of the modeling matched well with the measurements compared with the line source model alone and the prediction error reduced by about 50%. The study further demonstrated this with traffic emissions calculated by field and semi-empirical methods. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Bromine monoxide / sulphur dioxide ratios in relation to volcanological observations at Mt. Etna 2006–2009

    Directory of Open Access Journals (Sweden)

    G. Giuffrida

    2012-12-01

    Full Text Available Over a 3-yr period, from 2006 to 2009, frequent scattered sunlight DOAS measurements were conducted at Mt. Etna at a distance of around 6 km downwind from the summit craters. During the same period and in addition to these measurements, volcanic observations were made by regularly visiting various parts of Mt. Etna. Here, results from these measurements and observations are presented and their relation is discussed. The focus of the investigation is the bromine monoxide/sulphur dioxide (BrO / SO2 ratio, and its variability in relation to volcanic processes. That the halogen/sulphur ratio can serve as a precursor or indicator for the onset of eruptive activity was already proposed by earlier works (e.g. Noguchi and Kamiya 1963; Menyailov, 1975; Pennisi and Cloarec, 1998; Aiuppa et al., 2002. However, there is still a limited understanding today because of the complexity with which halogens are released, depending on magma composition and degassing conditions. Our understanding of these processes is far from complete, for example of the rate and mechanism of bubble nucleation, growth and ascent in silicate melts (Carroll and Holloway, 1994, the halogen vapour-melt partitioning and the volatile diffusivity in the melt (Aiuppa et al., 2009. With this study we aim to add one more piece to the puzzle of what halogen/sulphur ratios might tell about volcanic activities. Our data set shows an increase of the BrO / SO2 ratio several weeks prior to an eruption, followed by a decline before and during the initial phase of eruptive activities. Towards the end of activity or shortly thereafter, the ratio increases to baseline values again and remains more or less constant during quiet phases. To explain the observed evolution of the BrO / SO2 ratio, a first empirical model is proposed. This model suggests that bromine, unlike chlorine and fluorine, is less soluble in the magmatic melt than sulphur. By using the DOAS method to determine SO2, we actually

  13. Investigation of carbon monoxide at heavy traffic intersections of Karachi (Pakistan) using GIS to evaluate potential risk areas for respiratory and heart disease

    International Nuclear Information System (INIS)

    Shareef, A.; Azam, M.

    2011-01-01

    Measurement of carbon monoxide in the ambient air at 36 locations on the busy roads of Karachi showed peak values of CO at 18 sites to be within the permissible limit of 10 ppm whereas up to 70 ppm at the other 18 sites. The evaluated carboxy haemoglobin (COHb) level was in the range of 1.1 to 15.8 %. (author)

  14. Iron catalyst for preparation of polymethylene from synthesis gas and method for producing the catalyst

    Science.gov (United States)

    Sapienza, R.S.; Slegeir, W.A.

    1990-05-15

    This invention relates to a process for synthesizing hydrocarbons; more particularly, the invention relates to a process for synthesizing long-chain hydrocarbons known as polymethylene from carbon monoxide and hydrogen or from carbon monoxide and water or mixtures thereof in the presence of a catalyst comprising iron and platinum or palladium or mixtures thereof which may be supported on a solid material, preferably an inorganic refractory oxide. This process may be used to convert a carbon monoxide containing gas to a product which could substitute for high density polyethylene.

  15. The free radical scavenger, edaravone, ameliorates delayed neuropsychological sequelae after acute carbon monoxide poisoning in rabbits.

    Science.gov (United States)

    Qingsong, Wang; Yeming, Guan; Xuechun, Liu; Hongjuan, Liu; Jing, Wang

    2013-01-01

    The mechanism underlying delayed neuropsychological sequelae (DNS) after acute carbon monoxide (CO) poisoning is unclear. There are no effective treatments for DNS. As part of a new generation of antioxidants, edaravone has been reported to improve clinical outcomes in patients exhibiting ischemic strokes. There has been little data about edaravone in relationship to DNS prevention and treatment. We hypothesized that edaravone could ameliorate DNS: Here we test that hypothesis in rabbits Rabbits were randomly divided into sham control,DNS group, saline group and edaravone group. DNS model was made by intraperitoneal injection of CO. Normal saline or edaravone (1 mg/kg, twice daily, a total of one course for 14 days) was infused through the ear vein from Day 15 since the DNS model was established. Serum superoxide dismutase (SOD) activity and malondialdehyde (MDA) were measured in each group. Magnetic resonance spectroscopy (MRS) was used to examine regions of the brain for various compounds. The apoptotic index and neuronal density in the hippocampal CA1 area were also investigated. SOD activity decreased significantly and MDA content increased substantially in the DNS group and saline group when compared with the sham control (p edaravone group, serum SOD activity significantly increased and MDA levels significantly decreased when compared with DNS and saline group (p edaravone group (p edaravone group was significantly lower than that of the DNS and saline groups (p edaravone group was significantly higher than that of the DNS and saline group in the hippocampal CA1 area (p edaravone could ameliorate DNS after acute carbon monoxide poisoning in rabbits. These results suggest free radicals could be involved in the underlying mechanisms of DNS. Furthermore, brain MRS shows promise as a tool for early diagnosis for DNS.

  16. Variability in hyperbaric oxygen treatment for acute carbon monoxide poisoning.

    Science.gov (United States)

    Byrne, Brendan T; Lu, Jenny J; Valento, Matthew; Bryant, Sean M

    2012-01-01

    In patients with acute carbon monoxide (CO) poisoning, we have noted wide clinical variability in both criteria for hyperbaric oxygen (HBO2) treatment as well as HBO2 treatment regimens. Our aim was to survey Midwest hyperbaric centers for insight into specific criteria and protocols for treating acute CO toxicity with HBO2. Hyperbaric centers were identified from the published list of the Undersea and Hyperbaric Medical Society. Ninety-three centers from nine Midwestern states were contacted via telephone. A standard script was used to minimize surveyor bias. Thirty centers that treat CO poisonings were identified. One did not participate in the study. Nineteen reported a specific level of carboxyhemoglobin (COHb) that served as an independent indication for initiation of HBO2 treatment. Four centers used the COHb level as the exclusive indication for HBO2 treatment. Ten centers relied solely on reported symptoms, while the remaining centers used a combination of symptoms plus COHb levels. There were 19 separate treatment protocols. No uniform practice for either the initiation or implementation of HBO2 therapy for CO poisoning exists among U.S. Midwest hyperbaric centers responding to a survey. We see opportunity for specific targeted educational programs as well as further study.

  17. Estimation of the molecular hydrogen soil uptake and traffic emissions at a suburban site near Paris through hydrogen, carbon monoxide, and radon-222 semicontinuous measurements

    International Nuclear Information System (INIS)

    Yver, C.; Schmidt, M.; Bousquet, P.; Ramonet, M.; Bousquet, P.; Zahorowski, W.

    2009-01-01

    Since June 2006, simultaneous semicontinuous measurements of tropospheric molecular hydrogen (H 2 ), carbon monoxide (CO), and radon-222 ( 222 Rn) have been performed at Gif-sur-Yvette (Paris region), a suburban atmospheric measurement site in France. Molecular hydrogen mixing ratios range from 500 to 1000 ppb, CO mixing ratios vary from 100 to 1400 ppb, and 222 Rn concentrations fluctuate from 0 to 20 Bq m -3 . The H 2 seasonal cycle shows the expected pattern for the Northern Hemisphere with a maximum in spring and a minimum in autumn. We inferred a mean baseline value of 533 ppb with a peak-to-peak amplitude of 30 ppb. Carbon monoxide exhibits a seasonal cycle with a maximum in winter and a minimum in summer. The mean baseline value reaches 132 ppb with a peak-to-peak amplitude of 40 ppb. Radon-222 presents weak seasonal variations with a maximum in autumn/winter and a minimum in spring/summer. The diurnal cycles of H 2 and CO are dominated by emissions from nearby traffic with two peaks during morning and evening rush hours. The typical H 2 /CO emission ratio from traffic is found to be 0.47 ± 0.08 on a molar basis (ppb/ppb). The radon tracer method is applied to nighttime H 2 observations to estimate the H 2 soil uptake of the nocturnal catchment area of our sampling site. The influences from nocturnal local anthropogenic combustion sources are estimated by parallel measurements of CO at 0.14 * 10 -5 g(H 2 ) m -2 h -1 . The mean inferred dry deposition velocity is 0.024 ± 0.013 cm s -1 with a seasonal amplitude of 40% at Gif-sur-Yvette.

  18. Catalytic activity of Co/SiO2 and Co/TiO2 nanosized systems in the oxidation of carbon monoxide

    Science.gov (United States)

    Kelyp, A. A.; Smirnova, N. P.; Oleksenko, L. P.; Lutsenko, L. V.; Oranskaya, E. I.; Ripko, A. P.

    2013-06-01

    The effects of the preparation procedure, active component concentration, and conditions of formation of nanosized cobalt-containing systems based on TiO2 and SiO2 mesoporous powders on their catalytic activity in the oxidation of carbon monoxide were studied. The active phase in the systems was cobalt spinel CoCo2O4 found in all samples. High catalytic activity was found in the samples characterized by relatively high contents of surface active centers (cobalt cations with octahedral surroundings).

  19. Site blocking in silver-exchanged zeolite Y by carbon monoxide and ethene using xenon adsorption and 129Xe NMR spectroscopy

    Science.gov (United States)

    Boddenberg, B.; Watermann, J.

    1993-03-01

    The adsorption isotherms and 129Xe NMR chemical shifts of xenon in the zeolites NaY, AgY, and in AgY preloaded with ≈ 1 molecule/supercage ethene and carbon monoxide were measured at 25°C. The experimental data reveal the blocking of the silver-cation sites for xenon by the preadsorbed molecules. Ethene and CO are found to block the previously postulated two types of silver-cation species in the supercages of AgY in a different way.

  20. Fresh meat packaging: consumer acceptance of modified atmosphere packaging including carbon monoxide.

    Science.gov (United States)

    Grebitus, Carola; Jensen, Helen H; Roosen, Jutta; Sebranek, Joseph G

    2013-01-01

    Consumers' perceptions and evaluations of meat quality attributes such as color and shelf life influence purchasing decisions, and these product attributes can be affected by the type of fresh meat packaging system. Modified atmosphere packaging (MAP) extends the shelf life of fresh meat and, with the inclusion of carbon monoxide (CO-MAP), achieves significant color stabilization. The objective of this study was to assess whether consumers would accept specific packaging technologies and what value consumers place on ground beef packaged under various atmospheres when their choices involved the attributes of color and shelf life. The study used nonhypothetical consumer choice experiments to determine the premiums that consumers are willing to pay for extended shelf life resulting from MAP and for the "cherry red" color in meat resulting from CO-MAP. The experimental design allowed determination of whether consumers would discount foods with MAP or CO-MAP when (i) they are given more detailed information about the technologies and (ii) they have different levels of individual knowledge and media exposure. The empirical analysis was conducted using multinomial logit models. Results indicate that consumers prefer an extension of shelf life as long as the applied technology is known and understood. Consumers had clear preferences for brighter (aerobic and CO) red color and were willing to pay $0.16/lb ($0.35/kg) for each level of change to the preferred color. More information on MAP for extending the shelf life and on CO-MAP for stabilizing color decreased consumers' willingness to pay. An increase in personal knowledge and media exposure influenced acceptance of CO-MAP negatively. The results provide quantitative measures of how packaging affects consumers' acceptance and willingness to pay for products. Such information can benefit food producers and retailers who make decisions about investing in new packaging methods.