WorldWideScience

Sample records for monoxide percent predicted

  1. Characteristic and Prediction of Carbon Monoxide Concentration using Time Series Analysis in Selected Urban Area in Malaysia

    Directory of Open Access Journals (Sweden)

    Abdul Hamid Hazrul

    2017-01-01

    Full Text Available Carbon monoxide (CO is a poisonous, colorless, odourless and tasteless gas. The main source of carbon monoxide is from motor vehicles and carbon monoxide levels in residential areas closely reflect the traffic density. Prediction of carbon monoxide is important to give an early warning to sufferer of respiratory problems and also can help the related authorities to be more prepared to prevent and take suitable action to overcome the problem. This research was carried out using secondary data from Department of Environment Malaysia from 2013 to 2014. The main objectives of this research is to understand the characteristic of CO concentration and also to find the most suitable time series model to predict the CO concentration in Bachang, Melaka and Kuala Terengganu. Based on the lowest AIC value and several error measure, the results show that ARMA (1,1 is the most appropriate model to predict CO concentration level in Bachang, Melaka while ARMA (1,2 is the most suitable model with smallest error to predict the CO concentration level for residential area in Kuala Terengganu.

  2. Carbon monoxide, smoking, and atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Astrup, P

    1973-10-01

    Studies on the effects of carbon monoxide and smoking on atherosclerosis are reviewed. Nonsmokers do not run the risk of getting significantly elevated carboxyhemoglobin levels from automobile exhaust in the streets, however, they do run the risk of getting elevated carboxyhemoglobin levels from exposure to CO in closed areas such as garages and tunnels. Carboxyhemoglobin levels up to 20 percent may also be found in smokers. The central nervous system seems to be influenced by carboxyhemoglobin concentrations up to 20 percent. The myocardium may also be affected. Experimental work with rabbits exposed to carbon monoxide and cholesterol is described which proved that CO has a damaging effect on arterial walls, leading to increased permeability for various plasma components, to the formation of subendothelial edema, and to increased atheromatosis. The results indicate that the much higher risk of smokers of developing arterial disease in comparison to nonsmokers is mainly due to the inhaled CO in the tobacco smoke and not to nicotine. (Air Pollut. Abstr.)

  3. Carbon monoxide exposure in households in Ciudad Juárez, México.

    Science.gov (United States)

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  4. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  5. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  6. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  7. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  8. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    Science.gov (United States)

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  9. Recent changes in atmospheric carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Masarie, K.A. (Univ. of Colorado, Boulder, CO (United States)); Tans, P.P.; Lang, P.M. (National Oceanic and Atmospheric Administration, Boulder, CO (United States))

    1994-03-18

    Measurements of carbon monoxide (CO) in air samples collected from 27 locations between 71[degrees]N and 41[degrees]S show that atmospheric levels of this gas have decreased worldwide over the past 2 to 5 years. During this period, CO decreased at nearly a constant rate in the high northern latitudes. In contrast, in the tropics an abrupt decrease occurred beginning at the end of 1991. In the Northern Hemisphere, CO decreased at a spatially and temporally averaged rate of 7.3 ([+-]0.9) parts per billion per year (6.1 percent per year) from June 1990 to June 1993, whereas in the Southern Hemisphere, CO decreased 4.2 ([+-]0.5) parts per billion per year (7.0 percent per year). This recent change is opposite a long-term trend of a 1 to 2 percent per year increase inferred from measurements made in the Northern Hemisphere during the past 30 years.

  10. Serum bilirubin value predicts hospital admission in carbon monoxide-poisoned patients. Active player or simple bystander?

    Directory of Open Access Journals (Sweden)

    Gianfranco Cervellin

    Full Text Available OBJECTIVES: Although carbon monoxide poisoning is a major medical emergency, the armamentarium of recognized prognostic biomarkers displays unsatisfactory diagnostic performance for predicting cumulative endpoints. METHODS: We performed a retrospective and observational study to identify all patients admitted for carbon monoxide poisoning during a 2-year period. Complete demographical and clinical information, along with the laboratory data regarding arterial carboxyhemoglobin, hemoglobin, blood lactate and total serum bilirubin, was retrieved. RESULTS: The study population consisted of 38 poisoned patients (23 females and 15 males; mean age 39±21 years. Compared with discharged subjects, hospitalized patients displayed significantly higher values for blood lactate and total serum bilirubin, whereas arterial carboxyhemoglobin and hemoglobin did not differ. In a univariate analysis, hospitalization was significantly associated with blood lactate and total serum bilirubin, but not with age, sex, hemoglobin or carboxyhemoglobin. The diagnostic performance obtained after combining the blood lactate and total serum bilirubin results (area under the curve, 0.90; 95% CI, 0.81-0.99; p<0.001 was better than that obtained for either parameter alone. CONCLUSION: Although it remains unclear whether total serum bilirubin acts as an active player or a bystander, we conclude that the systematic assessment of bilirubin may, alongside lactate levels, provide useful information for clinical decision making regarding carbon monoxide poisoning.

  11. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Safety Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as CO, is called the " ...

  12. Hydrogen Oxidation on Gas Diffusion Electrodes for Phosphoric Acid Fuel Cells in the Presence of Carbon Monoxide and Oxygen

    DEFF Research Database (Denmark)

    Gang, Xiao; Li, Qingfeng; Hjuler, Hans Aage

    1995-01-01

    Hydrogen oxidation has been studied on a carbon-supported platinum gas diffusion electrode in a phosphoric acidelectrolyte in the presence of carbon monoxide and oxygen in the feed gas. The poisoning effect of carbon monoxide presentin the feed gas was measured in the temperature range from 80...... to 150°C. It was found that throughout the temperaturerange, the potential loss due to the CO poisoning can be reduced to a great extent by the injection of small amounts ofgaseous oxygen into the hydrogen gas containing carbon monoxide. By adding 5 volume percent (v/o) oxygen, an almost...

  13. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  14. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, ... Install one and check its batteries regularly. View Information About CO Alarms Other CO Topics Safety Tips ...

  15. Carbon monoxide toxicity. January 1978-March 1989 (Citations from the Life Sciences Collection data base). Report for January 1978-March 1989

    Energy Technology Data Exchange (ETDEWEB)

    1989-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 221 citations, 19 of which are new entries to the previous edition.)

  16. Carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The document identifies the main sources of carbon monoxide (CO) in the general outdoor atmosphere, describes methods of measuring and monitoring its concentration levels in the United Kingdom, and discusses the effects of carbon monoxide on human health. Following its review, the Panel has put forward a recommendation for an air quality standard for carbon monoxide in the United Kingdom of 10 ppm, measured as a running 8-hour average. The document includes tables and graphs of emissions of CO, in total and by emission source, and on the increase in blood levels of carboxyhaemoglobin with continuing exposure to CO. 11 refs., 4 figs., 4 tabs.

  17. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Kamal Mishra

    2016-01-01

    Full Text Available Introduction: Carbon monoxide is known as the silent killer, being colorless, odourless, and tasteless. Initially non-irritating, it is very difficult for people to detect Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply that prevents complete oxidation of carbon to C02. During World War II, Nazis used gas vans to kill an estimated over 700,000 prisoners by carbon monoxide poisoning. This method was also used in the gas chambers ofseveral death camps. The true number of incidents of carbon monoxide poisoning is unknown, since many non-lethal exposures go undetected From the available data, carbon monoxide poisoning is the most common cause of injury and death due to poisoning worldwide. Clinical features and management: The signs of carbon monoxide poisoning vary with concentration and length of exposure. Subtle cardiovascular or neurobehavioural effects occur at low concentration. The onset of chronic poisoning is usually insidious and easily mistaken for viral prodrome, depression, or gastroenteritis in children. The classic sign of carbon monoxide poisoning which is actually more often seen in the dead than the living is appearing red-cheeked and healthy. Cherry pink colour develops in nails, skin and mucosa. In acute poisoning, common abnormalities of posture and tone are cogwheel rigidity, opisthotonus, spasticity or flaccidity and seizures. Retinal haemorrhages and the classic cherry red skin colour are seldom seen. Different people andpopulations may have different carbon monoxide tolerance levels. On average, exposures at 100ppm or greater is dangerous to human health. Treatment and prevention: The mainstay of treatment is 100% oxygen administration until the COHb level is normal When the patient is stable enough to be transported, hyperbaric oxygen (HBOT should be considered This treatment is safe and well tolerated Public education about the danger of carbon monoxide, with

  18. Carbon monoxide toxicity. April 1978-November 1989 (A Bibliography from the Life Sciences Collection data base). Report for April 1978-November 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 237 citations, 16 of which are new entries to the previous edition.)

  19. Carbon Monoxide Safety

    Science.gov (United States)

    ... with the Media Fire Protection Technology Carbon monoxide safety outreach materials Keep your community informed about the ... KB | Spanish PDF 592 KB Handout: carbon monoxide safety Download this handout and add your organization's logo ...

  20. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... main content Languages 简体中文 English Bahasa Indonesia 한국어 Español ภาษาไทย Tiếng Việt Text Size: Decrease Font Increase ... Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as ...

  1. Carbon monoxide poisoning

    Science.gov (United States)

    ... Animals can also be poisoned by carbon monoxide. People who have pets at home may notice that their animals become ... or unresponsive from carbon monoxide exposure. Often the pets will ... these conditions. This can lead to a delay in getting help.

  2. Content of carbon monoxide in the tissues of rats intoxicated with carbon monoxide in various conditions of acute exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sokal, J.A.; Majka, J.; Palus, J.

    1984-12-01

    Tissue carbon monoxide (CO) content was investigated in rats severely intoxicated with CO under various exposure conditions: 1% CO for 4 min, 0.4% CO for 40 min and 0.12% CO for 12 h. Extravascular CO was determined in the heart and skeletal muscles immediately after termination of exposure, and carboxymyoglobin (MbCO) percent saturation was calculated. Total brain CO was estimated immediately after termination of exposure and after the time periods of restitution. After the same exposure conditions, MbCO percent saturation was higher in the heart than in skeletal muscle. In both types of muscle, saturation on myoglobin (Mb) with CO depended on blood carboxyhemoglobin (HbCO) level and not on the duration of exposure. The time course of CO elimination was the same for blood and brain, irrespective of CO exposure conditions. The results obtained showed that acute CO intoxication induced by long duration exposures did not involve CO accumulation in the tissues.

  3. Estimation of perimortal percent carboxy-heme in nonstandard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame atomic absorption spectrophotometry.

    Science.gov (United States)

    Middleberg, R A; Easterling, D E; Zelonis, S F; Rieders, F; Rieders, M F

    1993-01-01

    In decomposed, formalin-fixed, embalmed, exhumed, and some fire-dried cases in which normal blood is unavailable, the usual methods for determination of carboxyhemoglobin saturation frequently fail. To address these specimens, a method utilizing both gas chromatography/mass spectrometric (GC/MS) determination of carbon monoxide (CO) and flame atomic absorption spectrophotometry (FAAS) determination of iron (Fe), in the same specimen, was developed. The method is reported here, along with its application to seven pertinent forsensic death investigations. The CO analytical methodology involves acid liberation of the gas from the specimen aliquot in a headspace vial. After heating and equilibrating, a sample of the headspace vapor is injected into the GC/MS system with a gastight syringe. Quantitation is achieved by standard addition comparison utilizing the ideal gas law equation. Iron is quantified by FAAS analysis of the same aliquot used for the CO determination, following nitric acid digestion. The concentration is determined by comparison to a standard curve. A formula for determining the minimum percent carboxy-heme saturation was derived by using the ratio of the amount of CO to the amount of Fe in the aliquot analyzed. Tissue types analyzed include spleen, liver, muscle, dried blood, and unspecified decomposed tissue.

  4. Occult carbon monoxide poisoning.

    Science.gov (United States)

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  5. Carbon monoxide - hydrogen combustion characteristics in severe accident containment conditions. Final report

    International Nuclear Information System (INIS)

    2000-03-01

    Carbon monoxide can be produced in severe accidents from interaction of ex-vessel molten core with concrete. Depending on the particular core-melt scenario, the type of concrete and geometric factors affecting the interaction, the quantities of carbon monoxide produced can vary widely, up to several volume percent in the containment. Carbon monoxide is a combustible gas. The carbon monoxide thus produced is in addition to the hydrogen produced by metal-water reactions and by radiolysis, and represents a possibly significant contribution to the combustible gas inventory in the containment. Assessment of possible accident loads to containment thus requires knowledge of the combustion properties of both CO and H 2 in the containment atmosphere. Extensive studies have been carried out and are still continuing in the nuclear industry to assess the threat of hydrogen in a severe reactor accident. However the contribution of carbon monoxide to the combustion threat has received less attention. Assessment of scenarios involving ex-vessel interactions require additional attention to the potential contribution of carbon monoxide to combustion loads in containment, as well as the effectiveness of mitigation measures designed for hydrogen to effectively deal with particular aspects of carbon monoxide. The topic of core-concrete interactions has been extensively studied; for more complete background on the issue and on the physical/thermal-hydraulics phenomena involved, the reader is referred to Proceedings of CSNI Specialists Meetings (Ritzman, 1987; Alsmeyer, 1992) and a State-of-Art Report (European Commission, 1995). The exact amount of carbon monoxide present in a reactor pit or in various compartments (or rooms) in a containment building is specific to the type of concrete and the accident scenario considered. Generally, concrete containing limestone and sand have a high percentage of CaCO 3 . Appendix A provides an example of results of estimates of CO and CO 2

  6. Real-time prediction of extreme ambient carbon monoxide concentrations due to vehicular exhaust emissions using univariate linear stochastic models

    International Nuclear Information System (INIS)

    Sharma, P.; Khare, M.

    2000-01-01

    Historical data of the time-series of carbon monoxide (CO) concentration was analysed using Box-Jenkins modelling approach. Univariate Linear Stochastic Models (ULSMs) were developed to examine the degree of prediction possible for situations where only a limited data set, restricted only to the past record of pollutant data are available. The developed models can be used to provide short-term, real-time forecast of extreme CO concentrations for an Air Quality Control Region (AQCR), comprising a major traffic intersection in a Central Business District of Delhi City, India. (author)

  7. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Alisa Wray

    2016-07-01

    Full Text Available Audience: This oral boards case is appropriate for all emergency medicine learners (residents, interns, and medical students. Introduction: Carbon monoxide (CO is a colorless and odorless gas that typically results from combustion. It binds hemoglobin, dissociating oxygen, causing headache, weakness, confusion and possible seizure or coma. Pulse oxygen levels may be falsely elevated. Practitioners should maintain a high index of suspicion for carbon monoxide poisoning. If caught early CO poisoning is reversible with oxygen or hyperbaric oxygen therapy. Objectives: The learner will assess a patient with altered mental status and weakness, ultimately identifying that the patient has carbon monoxide poisoning. The learner will treat the patient with oxygen and admit/transfer the patient for hyperbaric oxygenation. Method: Oral boards case

  8. The Effect of Carbon Monoxide Poisoning on Platelet Volume in Children

    Directory of Open Access Journals (Sweden)

    Halise Akça

    2017-04-01

    Full Text Available Introduction: Carbon monoxide poisoning is one of the most important causes of morbidity and mortality. There is increasing evidence supporting the important role of mean platelet volume (MPV as a marker of hypoxia and inflammation. In this study, we aimed to determine changes in MPV values in pediatric patients with carbon monoxide poisoning. Methods: We retrospectively evaluated children who were diagnosed with carbon monoxide poisoning in our hospital between January 2005 and 2014. Results: We included 228 children with carbon monoxide poisoning (49% male in this retrospective, controlled study. The mean age of the patients was 88±56 months. Control group consisted of 200 age-matched healthy children. There was no statistically significant difference in MPV levels between the study and control groups (8.43±1.1 fL and 8.26±0.7 fL, respectively. No correlation of MPV and platelet count with carboxyhemoglobin (COHb was found. Conclusion: In our study, it was determined that MPV value was not a helpful parameter for predicting the diagnosis of acute carbon monoxide poisoning in childhood. The difference between the MPV values and the lack of significance and the absence of correlation between MPV value and COHb level led to the fact that MPV was not a guide indicating the clinical severity of the condition.

  9. Relationship between depression with FEV1 percent predicted and BODE index in chronic obstructive pulmonary disease

    Science.gov (United States)

    Gunawan, H.; Hanum, H.; Abidin, A.; Hanida, W.

    2018-03-01

    WHO reported more than 3 million people die from COPD in 2012 and are expected to rank third after cardiovascular and cancer diseases in the future. Recent studies reported the prevalence of depression in COPD patients was higher than in control group. So, it’s important for clinicians to understand the relationship of depression symptoms with clinical aspects of COPD. For determining the association of depression symptoms with lung function and BODE index in patients with stable COPD, a cross-sectional study was in 98 stable COPD outpatients from January to June 2017. Data were analyzed using Independent t-test, Mann-Whitney test, and Spearman’s rank correlation. COPD patients with depression had higher mMRC scores, and lower FEV1 percent predicted, and then 6-Minutes Walk Test compared to those without depression. There was a moderate strength of correlation (r=-0.43) between depression symptoms and FEV1 percent predicted, and strong correlation (r=0.614) between depression symptoms and BODE index. It indicates that BODE index is more accurate to describe symptoms of depression in COPD patients.

  10. Inhibition of photosynthesis by carbon monoxide and suspension of the carbon monoxide inhibition by light

    Energy Technology Data Exchange (ETDEWEB)

    Gewitz, H S; Voelker, W

    1963-08-01

    The experimental subject was the autotroph Chlorella pyrenoidosa. It was found that growth conditions determine whether the alga is inhibited by carbon monoxide or not. Respiration and photosynthesis are inhibited by carbon monoxide if the cells have grown rapidly under high light intensities. The inhibition of respiration and photosynthesis found in such cells is completely reversible. The inhibition depends not only on carbon monoxide pressure, but also on the oxygen pressure prevailing at the same time. 5 references, 1 figure, 3 tables.

  11. Running speed during training and percent body fat predict race time in recreational male marathoners.

    Science.gov (United States)

    Barandun, Ursula; Knechtle, Beat; Knechtle, Patrizia; Klipstein, Andreas; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald

    2012-01-01

    Recent studies have shown that personal best marathon time is a strong predictor of race time in male ultramarathoners. We aimed to determine variables predictive of marathon race time in recreational male marathoners by using the same characteristics of anthropometry and training as used for ultramarathoners. Anthropometric and training characteristics of 126 recreational male marathoners were bivariately and multivariately related to marathon race times. After multivariate regression, running speed of the training units (β = -0.52, P marathon race times. Marathon race time for recreational male runners may be estimated to some extent by using the following equation (r (2) = 0.44): race time ( minutes) = 326.3 + 2.394 × (percent body fat, %) - 12.06 × (speed in training, km/hours). Running speed during training sessions correlated with prerace percent body fat (r = 0.33, P = 0.0002). The model including anthropometric and training variables explained 44% of the variance of marathon race times, whereas running speed during training sessions alone explained 40%. Thus, training speed was more predictive of marathon performance times than anthropometric characteristics. The present results suggest that low body fat and running speed during training close to race pace (about 11 km/hour) are two key factors for a fast marathon race time in recreational male marathoner runners.

  12. Status epilepticus and cardiopulmonary arrest in a patient with carbon monoxide poisoning with full recovery after using a neuroprotective strategy: a case report

    Directory of Open Access Journals (Sweden)

    Abdulaziz Salman

    2012-12-01

    Full Text Available Abstract Introduction Carbon monoxide poisoning can be associated with life-threatening complications, including significant and disabling cardiovascular and neurological sequelae. Case presentation We report a case of carbon monoxide poisoning in a 25-year-old Saudi woman who presented to our facility with status epilepticus and cardiopulmonary arrest. Her carboxyhemoglobin level was 21.4 percent. She made a full recovery after we utilized a neuroprotective strategy and normobaric oxygen therapy, with no delayed neurological sequelae. Conclusions Brain protective modalities are very important for the treatment of complicated cases of carbon monoxide poisoning when they present with neurological toxicities or cardiac arrest. They can be adjunctive to normobaric oxygen therapy when the use of hyperbaric oxygen is not feasible.

  13.  Running speed during training and percent body fat predict race time in recreational male marathoners

    Directory of Open Access Journals (Sweden)

    Barandun U

    2012-07-01

    Full Text Available  Background: Recent studies have shown that personal best marathon time is a strong predictor of race time in male ultramarathoners. We aimed to determine variables predictive of marathon race time in recreational male marathoners by using the same characteristics of anthropometry and training as used for ultramarathoners.Methods: Anthropometric and training characteristics of 126 recreational male marathoners were bivariately and multivariately related to marathon race times.Results: After multivariate regression, running speed of the training units (β=-0.52, P<0.0001 and percent body fat (β=0.27, P <0.0001 were the two variables most strongly correlated with marathon race times. Marathon race time for recreational male runners may be estimated to some extent by using the following equation (r2 = 0.44: race time (minutes = 326.3 + 2.394 × (percent body fat, % – 12.06 × (speed in training, km/hours. Running speed during training sessions correlated with prerace percent body fat (r=0.33, P=0.0002. The model including anthropometric and training variables explained 44% of the variance of marathon race times, whereas running speed during training sessions alone explained 40%. Thus, training speed was more predictive of marathon performance times than anthropometric characteristics.Conclusion: The present results suggest that low body fat and running speed during training close to race pace (about 11 km/hour are two key factors for a fast marathon race time in recreational male marathoner runners.Keywords: body fat, skinfold thickness, anthropometry, endurance, athlete

  14. Interactions of carbon monoxide and hemoglobin at high altitude

    Energy Technology Data Exchange (ETDEWEB)

    Collier, C.R. (Univ. of Southern California Medical Center, Los Angeles); Goldsmith, J.R.

    1983-01-01

    The health risks to U.S. populations who are exposed to ambient carbon monoxide and live at altitudes (such as Denver, Salt Lake City, and Albuquerque) were evaluated using a set of mathematical models. The assumption that a given increase in carboxyhemoglobin would require a more stringent volumetric air quality standard was tested. The results using the model predict that the 8-h or 1-h standards adopted for sea level condition need not be altered to protect individuals against health risks at altitude, if the standards are in volumetric terms. They would need to be reduced if the standards are left in gravimetric terms. If the guideline is to be based on a given decrement of oxygen tension, many other variables must be specified, but expected differences in ambient carbon monoxide have a small impact compared to the effect of altitude itself.

  15. Occult Carbon Monoxide Poisoning

    OpenAIRE

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms ...

  16. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-01-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem. Images Figure 1 Figure 2 PMID:10379009

  17. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-07-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem.

  18. Percent voluntary inactivation and peak force predictions with the interpolated twitch technique in individuals with high ability of voluntary activation

    International Nuclear Information System (INIS)

    Herda, Trent J; Walter, Ashley A; Hoge, Katherine M; Stout, Jeffrey R; Costa, Pablo B; Ryan, Eric D; Cramer, Joel T

    2011-01-01

    The purpose of this study was to examine the sensitivity and peak force prediction capability of the interpolated twitch technique (ITT) performed during submaximal and maximal voluntary contractions (MVCs) in subjects with the ability to maximally activate their plantar flexors. Twelve subjects performed two MVCs and nine submaximal contractions with the ITT method to calculate percent voluntary inactivation (%VI). Additionally, two MVCs were performed without the ITT. Polynomial models (linear, quadratic and cubic) were applied to the 10–90% VI and 40–90% VI versus force relationships to predict force. Peak force from the ITT MVC was 6.7% less than peak force from the MVC without the ITT. Fifty-eight percent of the 10–90% VI versus force relationships were best fit with nonlinear models; however, all 40–90% VI versus force relationships were best fit with linear models. Regardless of the polynomial model or the contraction intensities used to predict force, all models underestimated the actual force from 22% to 28%. There was low sensitivity of the ITT method at high contraction intensities and the predicted force from polynomial models significantly underestimated the actual force. Caution is warranted when interpreting the % VI at high contraction intensities and predicted peak force from submaximal contractions

  19. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be safely...

  20. Thermal Reactions in Mixtures of Micron-sized Silicon Monoxide and Titanium Monoxide - Redox Paths Overcoming Passivation Shells.

    Czech Academy of Sciences Publication Activity Database

    Jandová, Věra; Pokorná, Dana; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, Petra; Pola, Josef

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 R&D Projects: GA TA ČR TA04010169 Institutional support: RVO:67985858 Keywords : silicon monoxide * titanium monoxide * hifh-temperature Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 1.369, year: 2016

  1. Thermal reactions in mixtures of micron-sized silicon monoxide and titanium monoxide: redox paths overcoming passivation shells

    Czech Academy of Sciences Publication Activity Database

    Jandová, V.; Pokorná, D.; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, P.; Pola, J.

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 Institutional support: RVO:61388980 Keywords : Silicon monoxide * Titanium monoxide * High-temperature * Oxygen-transfer reactions * Titanium suboxides * Titanium silicide * Methylene blue depletion Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.369, year: 2016

  2. Carbon monoxide: The 21st century poison that goes unnoticed

    International Nuclear Information System (INIS)

    Hoskins, J.A.

    1999-01-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described

  3. Carbon monoxide: The 21st century poison that goes unnoticed

    Energy Technology Data Exchange (ETDEWEB)

    Hoskins, J.A. [Reigate, Surrey (United Kingdom)

    1999-07-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described.

  4. Vacancy distribution in nonstoichiometric vanadium monoxide

    International Nuclear Information System (INIS)

    Gusev, A.I.; Davydov, D.A.; Valeeva, A.A.

    2011-01-01

    Graphical abstract: Display Omitted Research highlights: → A certain fraction of vanadium atoms in disordered cubic vanadium monoxide VO y and ordered tetragonal phase V 52 O 64 is located in tetrahedral positions of a basic cubic lattice. → These positions are never occupied by any atoms in other strongly nonstoichiometric carbides, nitrides and oxides. → Both disordered and ordered structures of vanadium monoxide are characterized by the presence of short-range order of displacements in the oxygen sublattice and short-range order of substitution in the metal sublattice. → The short-range order of displacement is caused by the local displacements of O atoms from V (t) atoms occupying tetrahedral positions. The short-range order of substitution appears because V (t) atoms in the tetrahedral positions are always in the environment of four vacancies □ of the vanadium sublattice. - Abstract: Structural vacancy distribution in the crystal lattice of the tetragonal V 52 O 64 superstructure which is formed on the basis of disordered superstoichiometric cubic vanadium monoxide VO y ≡V x O z is experimentally determined and the presence of significant local atomic displacements and large local microstrains in a crystal lattice of real ordered phase is established. It is shown that the relaxation of local microstrains takes place owing to the basic disordered cubic phase grain refinement and a formation of ordered phase domains. The ordered phase domains grow in the direction from the boundaries to the centre of grains of the disordered basic cubic phase. Isothermal evolution at 970 K of the average domain size in ordered VO 1.29 vanadium monoxide is established. It is shown that the short-range order presents in a metal sublattice of disordered cubic VO y vanadium monoxide. The character of the short-range order is such that vanadium atoms occupying tetrahedral positions are in the environment of four vacant sites of the vanadium sublattice. This means that the

  5. Enzymic oxidation of carbon monoxide. II

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, T

    1959-01-01

    An enzyme which catalyzes the oxidation of carbon monoxide into carbon dioxide was obtained in a cell free state from Desulfovibrio desulfuricans. The enzyme activity was assayed manometrically by measuring the rate of gas uptake under the atmosphere of carbon monoxide in the presence of benzyl-viologen as an oxidant. The optimum pH range was 7 to 8. The activity was slightly suppressed by illumination. The enzyme was more stable than hydrogenase or formate dehydrogenase against the heat treatment, suggesting that it is a different entity from these enzymes. In the absence of an added oxidant, the enzyme preparation produced hydrogen gas under the atmosphere of carbon monoxide. The phenomenon can be explained assuming the reductive decomposition of water. 17 references, 4 figures, 2 tables.

  6. Bacterium oxidizing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kistner, A

    1953-01-01

    Present-day knowledge of the microbiological oxidation of carbon monoxide is based on doubtful observations and imperfect experimental procedures. By making use of shake cultures in contact with gas mixtures containing high concentrations of CO and by employing liquid enrichment media with a low content of organic matter and solid media of the same composition with not more than 1.2% agar, it proved possible to isolate a co-oxidizing bacterium of the genus hydrogenomonas from sewage sludge. For the first time irrefutable proof has been given of the oxidation of carbon monoxide by a pure culture of a bacterium, both in growing cultures and in resting cell suspensions. 12 references.

  7. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008

    International Nuclear Information System (INIS)

    Lefebvre, B.; Chabot, L.; Gratton, J.; Lacoursiere, D.

    2009-01-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  8. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ...

  9. Search of medical literature for indoor carbon monoxide exposure

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  10. Delayed encephalopathy after acute carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet İbrahim Turan

    2014-03-01

    Full Text Available Carbon monoxide poisoning is a major cause of death following attempted suicide and accidental exposures. Although clinical presentation depends on the duration and the intensity of exposure, the assessment of the severity of intoxication is difficult. A small percentage of patients who show complete initial recovery may develop delayed neurological deficits. Delayed encephalopathy after acute carbon monoxide poisoning is a rare and poor prognosis neurologic disorders and there is no specific treatment. We present a case with early onset of delayed encephalopathy after acute carbon monoxide poisoning with typical cranial imaging findings in a child with atypical history and clinical presentation.

  11. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Import Surveillance International Recall Guidance Civil and Criminal Penalties Federal Court Orders & ... 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 ...

  12. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias

    2013-09-15

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  13. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    International Nuclear Information System (INIS)

    Stollenwerk, Tobias

    2013-09-01

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  14. Using ANN and EPR models to predict carbon monoxide concentrations in urban area of Tabriz

    Directory of Open Access Journals (Sweden)

    Mohammad Shakerkhatibi

    2015-09-01

    Full Text Available Background: Forecasting of air pollutants has become a popular topic of environmental research today. For this purpose, the artificial neural network (AAN technique is widely used as a reliable method for forecasting air pollutants in urban areas. On the other hand, the evolutionary polynomial regression (EPR model has recently been used as a forecasting tool in some environmental issues. In this research, we compared the ability of these models to forecast carbon monoxide (CO concentrations in the urban area of Tabriz city. Methods: The dataset of CO concentrations measured at the fixed stations operated by the East Azerbaijan Environmental Office along with meteorological data obtained from the East Azerbaijan Meteorological Bureau from March 2007 to March 2013, were used as input for the ANN and EPR models. Results: Based on the results, the performance of ANN is more reliable in comparison with EPR. Using the ANN model, the correlation coefficient values at all monitoring stations were calculated above 0.85. Conversely, the R2 values for these stations were obtained <0.41 using the EPR model. Conclusion: The EPR model could not overcome the nonlinearities of input data. However, the ANN model displayed more accurate results compared to the EPR. Hence, the ANN models are robust tools for predicting air pollutant concentrations.

  15. Hydrogenation of carbon monoxide over supported palladium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K.; Hashimoto, H.; Kunugi, T.

    1978-03-01

    An alumina-supported 2% palladium catalyst had higher activity for carbon monoxide hydrogenation than a silica-supported 2% palladium catalyst, at 250/sup 0/-400/sup 0/C and 1 atm. The addition of lanthanum oxide or thorium oxide, but not of potassium oxide, to the silica-supported catalyst increased the conversion at 350/sup 0/C from 1.1% to 81.0% with a selectivity of 56.1% for methane, 1.4% for C/sub 2/ compounds, 0.1% for C/sub 3/ compounds, and 42.5% for carbon dioxide. Temperature-programed desorption of carbon monoxide in a hydrogen stream showed that of two desorption peaks observed for carbon monoxide, the one at higher temperature corresponded to the carbon monoxide species which hydrogenates to methane and that the area of this peak increased with increasing thorium content of the catalyst. Graphs, tables, and 12 references.

  16. Geostatistical modelling of carbon monoxide levels in Khartoum State (Sudan) - GIS pilot based study

    Energy Technology Data Exchange (ETDEWEB)

    Alhuseen, A [Comenius University in Bratislava, Faculty of Natural Sciences, Dept. of Landscape Ecology, 84215 Bratislava (Slovakia); Madani, M [Ministry of Environment and Physical Development, 1111 Khartoum (Sudan)

    2012-04-25

    The objective of this study is to develop a digital GIS model; that can evaluate, predict and visualize carbon monoxide (CO) levels in Khartoum state. To achieve this aim, sample data had been collected, processed and managed to generate a dynamic GIS model of carbon monoxide levels in the study area. Parametric data collected from the field and analysis carried throughout this study show that (CO) emissions were lower than the allowable ambient air quality standards released by National Environment Protection Council (NEPC-USA) for 1998. However, this pilot study has found emissions of (CO) in Omdurman city were the highest. This pilot study shows that GIS and geostatistical modeling can be used as a powerful tool to produce maps of exposure. (authors)

  17. Carbon Monoxide Nonattainment Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies areas in the U.S. where air pollution levels have not met the National Ambient Air Quality Standards (NAAQS) for Carbon Monoxide and have...

  18. The electric dipole moment of cobalt monoxide, CoO.

    Science.gov (United States)

    Zhuang, Xiujuan; Steimle, Timothy C

    2014-03-28

    A number of low-rotational lines of the E(4)Δ7/2 ← X(4)Δ7/2 (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h7/2, and the electron quadrupole parameter, eQq0, for the E(4)Δ7/2(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ(→)(el), for the X(4)Δ7/2 (υ = 0) and E(4)Δ7/2 (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F' = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F' = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  19. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 Annual Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire ...

  20. Effect of vegetation in reducing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, J C

    1977-01-01

    Carbon monoxide is a product of incomplete combustion. Because almost all of this gas is produced by motor vehicles, it is considered to have a line rather than a stationary point source. Greatest concentrations of this lethal gas correspond to periods of peak traffic volume and congestion; therefore, there are two daily periods of maxima and minima. Carbon monoxide cannot be detected by sight or smell. For this reason, this gas is especially deadly. During the summer of 1975, a study involving carbon monoxide concentrations at selected sites in Sendai was undertaken in conjunction with an ongoing investigation of urban pollution under the directorship of Professor Toshio Noh of Tohoku University. This study was made possible by a grant from the Japan Society for the Promotion of Science. 5 references, 5 figures, 1 table.

  1. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Community Outreach Resource Center Toy Recall Statistics CO Poster Contest Pool Safely Business & Manufacturing Business & Manufacturing Business ... Featured Resources CPSC announces winners of carbon monoxide poster contest Video View the blog Clues You Can ...

  2. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  3. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ... 2011 Annual Estimates View All CO-Related Injury Statistics and Technical Reports Related Links Recalls Safety Education ...

  4. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... CONSUMER PRODUCT SAFETY COMMISSION Search CPSC Search Menu Home Recalls Recall List CPSC Recall API Recall Lawsuits ... and Bans Report an Unsafe Product Consumers Businesses Home Safety Education Safety Education Centers Carbon Monoxide Information ...

  5. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  6. Kinetics of the fixation of carbon monoxide in the blood. III. Dose received and dose retained: significance of pollution peaks

    Energy Technology Data Exchange (ETDEWEB)

    Chovin, P.

    1974-01-01

    The kinetics of the retention of carbon monoxide in the blood is discussed with respect to certain CO concentration standards. The ratio of the amount of CO retained by the blood to the amount inhaled is independent of the CO concentration in the inhaled air and increases with decreasing exposure time. An exposure to 50 ppM CO for 8 hr causes a carboxyhemoglobin level of 5.5 percent, corresponding to a retention rate of 31.5 percent, while exposure to the same concentration for 30 min results in a retention rate of 55 percent. With the dose inhaled being constant, the COHb level varies as a function of time, increasing with shortening of the exposure time, which emphasizes the hazards of high CO peaks in street air. Exposure to 40 ppM CO for 1 hr and to 10 ppM CO for 12 hr according to the California standard will result increases in the COHb level by 0.93 percent and 1.3 percent, respectively. The inconsistency of U.S. standards is further demonstrated by the great divergence between the safety factors calculated for exposure to the maximum allowable concentrations for the respective maximum allowable durations.

  7. Selected constituents in the smokes of U. S. commercial cigaretts: tar, nicotine, carbon monoxide and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    One hundred twenty-one brands of United States commercial cigarettes were analyzed for their deliveries of tar, nicotine, carbon monoxide, and carbon dioxide under standard analytical smoking conditions. The sample included both filter and nonfilter cigarettes. Comparisons of carbon monoxide deliveries over the range of observed tar deliveries indicated a very high correlation between CO and tar for filter cigarettes, but nonfilter cigarettes tended to produce much less CO than would have been predicted from their tar deliveries. Comparison of ORNL nicotine values for specific brands with those determined by the Federal Trade Commission yield no statistically significant differences between laboratories. 4 figures, 6 tables.

  8. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide ... Related Links Recalls Safety Education Regulations, Laws & Standards Research & Statistics Business & Manufacturing Small Business Resources OnSafety Blogs ...

  9. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Español The Invisible Killer Carbon monoxide, also known as CO, is called the "Invisible Killer" because it's ... used or incorrectly-vented fuel-burning appliances such as furnaces, stoves, water heaters and fireplaces. Watch This ...

  10. Lack of pupil reflex and loss of consciousness predict 30-day neurological sequelae in patients with carbon monoxide poisoning.

    Directory of Open Access Journals (Sweden)

    Jian-Fang Zou

    Full Text Available Predicting the neurological sequelae of carbon monoxide poisoning (COP has not been well studied. We investigated the independent predictors of neurological sequelae in patients with COP and combined these predictors to predict the prognosis.This study was conducted at four hospitals in Shandong Province, China. Data were retrospectively collected from 258 patients with COP between November 1990 and October 2011. Thirty-day neurological sequelae were the primary endpoints.A lack of pupil reflex and a loss of consciousness appear to be independent predictors for neurological sequelae in patients with COP. The presence of either one had a sensitivity of 77.0% (95% confidence interval [CI]: 69.3-83.2, a specificity of 47.1% (95% CI: 38.3-56.0, positive predictive value (PPV of 62.9% (95% CI: 55.2-70.1, and a negative predictive value (NPV of 63.6% (95% CI: 52.6-73.4. With both predictors present, the sensitivity was 11.5% (95% CI: 6.9 to 18.3, the specificity was 99.2 (95% CI: 94.7-100.0, the PPV was 94.1% (95% CI: 69.2-99.7, and the NPV was 49.0% (95% CI: 42.5-55.5.The risk for neurological sequelae apparently increased with the number of independent predictors. In patients with both predictors, the risk for neurological sequelae was 94.1%. Almost all (99.2% patients with neither predictor had no neurological sequelae. This finding may help physicians make decisions about and dispositions for patients with COP. For patients with a higher risk, earlier treatment and more appropriate utilization of health care services, including hyperbaric oxygen, should be considered.

  11. Delayed neuropsychological sequelae after carbon monoxide poisoning: predictive risk factors in the Emergency Department. A retrospective study

    Directory of Open Access Journals (Sweden)

    Botti Primo

    2011-03-01

    Full Text Available Abstract Background Delayed neuropsychological sequelae (DNS commonly occur after recovery from acute carbon monoxide (CO poisoning. The preventive role and the indications for hyperbaric oxygen therapy in the acute setting are still controversial. Early identification of patients at risk in the Emergency Department might permit an improvement in quality of care. We conducted a retrospective study to identify predictive risk factors for DNS development in the Emergency Department. Methods We retrospectively considered all CO-poisoned patients admitted to the Emergency Department of Careggi University General Hospital (Florence, Italy from 1992 to 2007. Patients were invited to participate in three follow-up visits at one, six and twelve months from hospital discharge. Clinical and biohumoral data were collected; univariate and multivariate analysis were performed to identify predictive risk factors for DNS. Results Three hundred forty seven patients were admitted to the Emergency Department for acute CO poisoning from 1992 to 2007; 141/347 patients participated in the follow-up visit at one month from hospital discharge. Thirty four/141 patients were diagnosed with DNS (24.1%. Five/34 patients previously diagnosed as having DNS presented to the follow-up visit at six months, reporting a complete recovery. The following variables (collected before or upon Emergency Department admission were associated to DNS development at one month from hospital discharge in the univariate analysis: CO exposure duration >6 hours, a Glasgow Coma Scale (GCS score Conclusions Our study identified several potential predictive risk factors for DNS. Treatment algorithms based on an appropriate risk-stratification of patients in the Emergency Department might reduce DNS incidence; however, more studies are needed. Adequate follow-up after hospital discharge, aimed at correct recognition of DNS, is also important.

  12. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Investigations Associated with Non-Fire Carbon Monoxide from Engine-Driven Generators and Other Engine-Driven Tools, 2004–2014 JANUARY 08, 2015 Non- ... outside of the Federal Government. CPSC does not control this external site or its privacy policy and ...

  13. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Sevinc, A.; Savli, H.; Atmaca, H. [Gaziantep University, Gaziantep (Turkey). School of Medicine

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  14. Polyketones as alternating copolymers of carbon monoxide

    International Nuclear Information System (INIS)

    Belov, Gennady P; Novikova, Elena V

    2004-01-01

    Characteristic features of the catalytic synthesis of alternating copolymers of carbon monoxide with various olefins, dienes, styrene and its derivatives are considered. The diversity of catalyst systems used for the copolymerisation of carbon monoxide is demonstrated and their influence on the structure and the molecular mass of the resulting copolymers is analysed. The data on the structure and physicochemical and mechanical properties of this new generation of functional copolymers are generalised and described systematically for the first time.

  15. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker...... after an acute exposure to carbon monoxide. This complication was diagnosed by pure-tone audiometry and confirmed by transient evoked otoacoustic emissions. Hearing loss has not improved after 3 months of followup....

  16. Development of an enzymatic sensor for carbon monoxide

    International Nuclear Information System (INIS)

    Hurtado, Clara; Gomez, Diana; Larmat, Fernando; Torres, Walter; Cuervo, Raul; Bravo, Enrique; Benitez, Neyla

    2003-01-01

    The detection and the pursuit of gases that contribute in the increase of the atmospheric contamination are a necessity, for what the electrochemical sensors have potential industrial applications for the control of the quality of the air. The development of amperometric sensor based on enzymes offers advantages, since the use of the biological component provides him high selectivity due to the great specificity of the substrate of the enzyme. The monoxide of carbon (CO) it is a polluting, poisonous gas, taken place during the incomplete combustion of organic materials (natural gas, petroleum, gasoline, coal and vegetable material). The determination of monoxide of carbon (CO) it can be reached by electrochemical mediums using the methylene blue like the electronic mediator for the enzyme monoxide of carbon oxidase (COx)

  17. The electric dipole moment of cobalt monoxide, CoO

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Xiujuan, E-mail: zhuangxj@hnu.edu.cn [College of Physics and Microelectronics Science, Key Laboratory for Micro-Nano Physics and Technology of Hunan Province, Hunan University, Changsha 410082 (China); Steimle, Timothy C. [Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287-1604 (United States)

    2014-03-28

    A number of low-rotational lines of the E{sup 4}Δ{sub 7/2} ← X{sup 4}Δ{sub 7/2} (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h{sub 7/2}, and the electron quadrupole parameter, eQq{sub 0}, for the E{sup 4}Δ{sub 7/2}(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ{sup -vector}{sub el}, for the X{sup 4}Δ{sub 7/2} (υ = 0) and E{sup 4}Δ{sub 7/2} (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F′ = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F′ = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  18. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Science.gov (United States)

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  19. Metallic and insulating 3d transition-element monoxides and their stability

    International Nuclear Information System (INIS)

    Johansson, H.B.

    1977-01-01

    The binding properties of the 3d monoxides are studied in detail, and it is shown that the metallic character of TiO and VO is directly reflected in their heat of formation. The same holds true for NbO. From a stability analysis of the 3d monoxides versus decomposition, it is found that TiO, VO, and FeO are close to an instability. Further, it can be concluded that both ScO and CrO must be very near existence. The general occurrence of transition-metal monoxides is shown to be directly correlated with ionic properties of the transition elements. An investigation of the absorption edge in the 3d monoxides is also undertaken. The importance of the crystal-field splitting is noticed, and it is shown that the heat of formation of the monoxides can be used to derive the crystal-field parameter Δ. The change from a delocalized to a localized behavior of the d electrons in the 3d monoxides is compared with a similar change of the f electrons in the actinides. Some similarities between these two series of materials are pointed out

  20. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  1. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Science.gov (United States)

    2010-07-01

    ... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration. Prior... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  2. Poisoning by carbon monoxide in the hydrogen exchange reaction between deuterium gas and water preadsorbed on a platinum--alumina catalyst

    International Nuclear Information System (INIS)

    Iida, I.; Tamaru, K.

    1979-01-01

    Poisoning by carbon monoxide in the exchange reaction between deuterium and the water preadsorbed on a platinum--alumina catalyst was studied, by measuring not only the rate of reaction but also its kinetic behavior and the adsorption of reactants on the catalyst surface. The shape of the poisoning curve is closely associated with the kinetic behavior and exhibited an abrupt change on freezing the adsorbed water below 273 0 K. When the rate is proportional to deuterium pressure and independent of the amount of water adsorbed, the exchange rate dropped sharply by carbon monoxide adsorbed of a few percent coverage without any marked changes in the amount and the rate of hydrogen adsorption on the platinum surface. However, at temperatures lower than 273 0 K and at higher deuterium pressures, the rate depends not on the deuterium pressure but on the amount of water adsorbed. The migration of hydrogen in or through the adsorbed water is seemingly sufficiently suppressed by freezing to control the overall reaction rate. In this case, a small amount of adsorption of carbon monoxide did not show any toxicity, but then a steep poisoning started accompanying a change in the kinetic behavior. It was accordingly demonstrated that the mechanism of the reaction may be better understood by studying poisoning and measuring adsorption, overall rate, and kinetic behavior

  3. Occupational medicine effects of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, W.M. [South African Society of Occupational Medicine (South Africa)

    1998-10-01

    Carbon monoxide can affect the body if it is inhaled or if liquid carbon monoxide comes in contact with the eyes or skin. The effects of overexposure are discussed and a brief explanation of the toxicological effects of CO given. Methods of control of CO from common operations (exhaust fumes of internal combustion engines, the chemical industry and foundries, welding, mines or tunnels, fire damp explosions, industrial heating) are by local exhaust ventilation or use of a respiratory protective device. The South African hazardous chemical substance regulation NO. R. 1179 of 25 August 1995 stipulates maximum safe levels of CO concentration. 4 refs., 1 photo.

  4. Carbon monoxide poisoning from waterpipe smoking: a retrospective cohort study.

    Science.gov (United States)

    Eichhorn, Lars; Michaelis, Dirk; Kemmerer, Michael; Jüttner, Björn; Tetzlaff, Kay

    2018-04-01

    Waterpipe smoking may increasingly account for unintentional carbon monoxide poisoning, a serious health hazard with high morbidity and mortality. We aimed at identifying waterpipe smoking as a cause for carbon monoxide poisoning in a large critical care database of a specialty care referral center. This retrospective cohort study included patients with a history of exposure to waterpipe smoking and carbon monoxide blood gas levels >10% or presence of clinical symptoms compatible with CO poisoning admitted between January 2013 and December 2016. Patients' initial symptoms and carbon monoxide blood levels were retrieved from records and neurologic status was assessed before and after hyperbaric oxygen treatment. Sixty-one subjects with carbon monoxide poisoning were included [41 males, 20 females; mean age 23 (SD ± 6) years; range 13-45] with an initial mean carboxyhemoglobin of 26.93% (SD ± 9.72). Most common symptoms included syncope, dizziness, headache, and nausea; 75% had temporary syncope. Symptoms were not closely associated with blood COHb levels. CO poisoning after waterpipe smoking may present in young adults with a wide variability of symptoms from none to unconsciousness. Therefore diagnosis should be suspected even in the absence of symptoms.

  5. Ischemia-modified albumin levels in the prediction of acute critical neurological findings in carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Murat Daş

    2016-04-01

    Full Text Available The aim of the study was to determine whether serum ischemia-modified albumin (IMA levels in patients with carbon monoxide (CO poisoning were higher compared with a control group of healthy volunteers. In addition, the study sought to determine if there was a correlation between serum IMA levels and carboxyhemoglobin (COHB levels and other critical neurological findings (CNFs. In this prospective study, the IMA levels of 100 patients with CO poisoning and 50 control individuals were compared. In addition, the IMA and COHB levels were analyzed according to absence or presence CNFs in patients with CO poisoning. The levels of IMA (mg/dL on admittance, and during the 1st hour and 3rd hour, in patients with CO poisoning (49.90 ± 35.43, 30.21 ± 14.81, and 21.87 ± 6.03 were significantly higher, compared with the control individuals (17.30 ± 2.88. The levels of IMA in the 6th hour were not higher compared with control individuals. The levels of IMA on admittance, and during the 1st hour, 3rd hour, and 6th hour, and COHB (% levels in patients who had CNFs were higher compared with IMA levels and COHB levels in patients who had no CNFs (p < 0.001. However, when the multivariate model was created, it was observed that IMA level on admittance was a poor indicator for prediction of CNFs (odds ratio = 1.05; 95% confidence interval, 1.01–1.08. We therefore concluded that serum IMA levels could be helpful in the diagnosis of CO poisoning. However, we believe that IMA levels cannot be used to predict which patients will develop CNFs due to CO poisoning.

  6. Method of removing nitrogen monoxide from a nitrogen monoxide-containing gas using a water-soluble iron ion-dithiocarbamate, xanthate or thioxanthate

    Science.gov (United States)

    Liu, D. Kwok-Keung; Chang, Shih-Ger

    1987-08-25

    The present invention relates to a method of removing of nitrogen monoxide from a nitrogen monoxide-containing gas which method comprises contacting a nitrogen oxide-containing gas with an aqueous solution of water soluble organic compound-iron ion chelate complex. The NO absorption efficiency of ferrous urea-dithiocarbamate and ferrous diethanolamine-xanthate as a function of time, oxygen content and solution ph is presented. 3 figs., 1 tab.

  7. Hydrogen bonding of formamide, urea, urea monoxide and their thio

    Indian Academy of Sciences (India)

    Ab initio and DFT methods have been employed to study the hydrogen bonding ability of formamide, urea, urea monoxide, thioformamide, thiourea and thiourea monoxide with one water molecule and the homodimers of the selected molecules. The stabilization energies associated with themonohydrated adducts and ...

  8. Carbon monoxide poisoning - Immediate diagnosis and treatment are crucial to avoid complications.

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, L.D. [Case Western Reserve University, Cleveland, OH (United States)

    2006-03-15

    Carbon monoxide is an odorless, colorless, tasteless gas produced by the incomplete combustion of carbon-containing fuels (oil, kerosene, coal, wood) or the inadequate ventilation of natural gas. When carbon monoxide is introduced into the bloodstream, it binds to hemoglobin, reducing the number of binding sites available for oxygen. Carbon monoxide also changes the structure of the hemoglobin molecule, which makes it even more difficult for oxygen that has attached to be released into tissues. The resulting tissue ischemia can lead to organ failure, permanent changes in cognition, or death. Carbon monoxide poisoning is the leading cause of death by poisoning in industrialized countries.

  9. Pulmonary edema in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk

    1974-01-01

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis

  10. Pulmonary edema in acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis.

  11. An evaluation of 10 percent and 20 percent benzocaine gels in patients with acute toothaches

    Science.gov (United States)

    Hersh, Elliot V.; Ciancio, Sebastian G.; Kuperstein, Arthur S.; Stoopler, Eric T.; Moore, Paul A.; Boynes, Sean G.; Levine, Steven C.; Casamassimo, Paul; Leyva, Rina; Mathew, Tanya; Shibly, Othman; Creighton, Paul; Jeffers, Gary E.; Corby, Patricia M.A.; Turetzky, Stanley N.; Papas, Athena; Wallen, Jillian; Idzik-Starr, Cynthia; Gordon, Sharon M.

    2013-01-01

    Background The authors evaluated the efficacy and tolerability of 10 percent and 20 percent benzocaine gels compared with those of a vehicle (placebo) gel for the temporary relief of toothache pain. They also assessed the compliance with the label dose administration directions on the part of participants with toothache pain. Methods Under double-masked conditions, 576 participants self-applied study gel to an open tooth cavity and surrounding oral tissues. Participants evaluated their pain intensity and pain relief for 120 minutes. The authors determined the amount of gel the participants applied. Results The responders’ rates (the primary efficacy parameter), defined as the percentage of participants who had an improvement in pain intensity as exhibited by a pain score reduction of at least one unit on the dental pain scale from baseline for two consecutive assessments any time between the five- and 20-minute points, were 87.3 percent, 80.7 percent and 70.4 percent, respectively, for 20 percent benzocaine gel, 10 percent benzocaine gel and vehicle gel. Both benzocaine gels were significantly (P ≤ .05) better than vehicle gel; the 20 percent benzocaine gel also was significantly (P ≤ .05) better than the 10 percent benzocaine gel. The mean amount of gel applied was 235.6 milligrams, with 88.2 percent of participants applying 400 mg or less. Conclusions Both 10 percent and 20 percent benzocaine gels were more efficacious than the vehicle gel, and the 20 percent benzocaine gel was more efficacious than the 10 percent benzocaine gel. All treatments were well tolerated by participants. Practical Implications Patients can use 10 percent and 20 percent benzocaine gels to temporarily treat toothache pain safely. PMID:23633700

  12. Carbon monoxide and COHb concentration in blood in various circumstances

    Energy Technology Data Exchange (ETDEWEB)

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  13. Poisoning by carbon monoxide in Morocco from 1991 to 2008.

    Science.gov (United States)

    Aghandous, Rachida; Chaoui, Hanane; Rhalem, Naima; Semllali, Ilham; Badri, Mohamed; Soulaymani, Abdelmajid; Ouammi, Lahcen; Soulaymani-Bencheikh, Rachida

    2012-04-01

    To describe the characteristics relating to the provenance of statements, patients and to evaluate the spatiotemporal evolution of carbon monoxide poisoning reported to Poison Control Center and Pharmacovigilance of Morocco (CAPM). This is a retrospective study over a period of 18 years from 1991 to 2008, for all cases of poisoning by carbon monoxide reported to CAPM. The epidemiological study focused on 12 976 cases of carbon monoxide poisoning reported to CAPM between 1991 and 2008. The average age of patients was 25.5 +/- 15.6 years, sex ratio was 0.5. The poisoning occurred by accident in 98.7% of cases, especially at home (96.7%) and in cold months. The urban population was the most affected (89.0%). The region of Meknes Tafilalt was the most concerned with 16.6% of cases. The symptomatology was characterized by the predominance of gastrointestinal tract diseases (37.1%). Deaths have reached a percentage of 0.9%. These qualitative and quantitative information is useful to highlight warnings and plan a strategy against carbon monoxide poisoning in Morocco.

  14. Protect Yourself from Carbon Monoxide Poisoning

    Centers for Disease Control (CDC) Podcasts

    2007-11-20

    Learn about carbon monoxide - a colorless, odorless gas - and how to protect yourself and your family.  Created: 11/20/2007 by CDC National Center for Environmental Health.   Date Released: 12/4/2007.

  15. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Science.gov (United States)

    2010-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  16. [Protective effects of endogenous carbon monoxide against myocardial ischemia-reperfusion injury in rats].

    Science.gov (United States)

    Zhou, Zhen; Ma, Shuang; Liu, Jie; Ji, Qiao-Rong; Cao, Cheng-Zhu; Li, Xiao-Na; Tang, Feng; Zhang, Wei

    2018-04-25

    The present study is aimed to explore the effects of endogenous carbon monoxide on the ischemia-reperfusion in rats. Wistar rats were intraperitoneally injected with protoporphyrin cobalt chloride (CoPP, an endogenous carbon monoxide agonist, 5 mg/kg), zinc protoporphyrin (ZnPP, an endogenous carbon monoxide inhibitor, 5 mg/kg) or saline. Twenty-four hours after injection, the myocardial ischemia-reperfusion model was made by Langendorff isolated cardiac perfusion system, and cardiac function parameters were collected. Myocardial cGMP content was measured by ELISA, and the endogenous carbon monoxide in plasma and myocardial enzymes in perfusate at 10 min after reperfusion were measured by colorimetry. The results showed that before ischemia the cardiac functions of CoPP, ZnPP and control groups were stable, and there were no significant differences. After reperfusion, cardiac functions had significant differences among the three groups (P endogenous carbon monoxide can maintain cardiac function, shorten the time of cardiac function recovery, and play a protective role in cardiac ischemia-reperfusion.

  17. Carbon monoxide and carbon dioxide interaction with tantalum

    International Nuclear Information System (INIS)

    Belov, V.D.; Ustinov, Yu.K.; Komar, A.P.

    1978-01-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (α and β' 1 ) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the β' 1 state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10 12 sec -1 , and γ = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively. (Auth.)

  18. Carbon monoxide and carbon dioxide interaction with tantalum

    Energy Technology Data Exchange (ETDEWEB)

    Belov, V D; USTINOV, YU K; KOMAR, A P [AN SSSR, LENINGRAD. FIZIKO-TEKHNICHESKIJ INST.

    1978-03-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (..cap alpha.. and ..beta..'/sub 1/) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the ..beta..'/sub 1/ state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10/sup 12/ sec/sup -1/, and ..gamma.. = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively.

  19. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    Science.gov (United States)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  20. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  1. Study of photoionization and dissociative photoionization of carbon monoxide from ionization threshold to 38 eV by using synchrotron radiation

    International Nuclear Information System (INIS)

    Zhao, Yujie; Cao, Maoqi; Li, Yuquan; Shan, Xiaobin; Liu, Fuyi; Sheng, Liusi; Li, Li; Liu, Wanfang

    2014-01-01

    Highlights: • The high resolution photoionization spectrum of carbon monoxide has been investigated using tunable synchrotron radiation. • This work has investigated comprehensively almost all kinds of photo excitation processes of CO in wide photon region. • The mechanisms of photoionization and dissociative photoionization of CO have been researched in detail. - Abstract: The vacuum-ultraviolet photoionization and dissociative photoionization of carbon monoxide in a region 14–38 eV have been investigated with time-of-flight (TOF) photoionization mass spectrometry (PIMS) using tunable synchrotron radiation (SR). The adiabatic ionization energy (IE) of carbon monoxide and appearance energies (AE) for its fragment ions in different states are determined by measurements of photoionization efficiency spectra (PIES). Ab initio calculations have been performed to investigate the reaction mechanism of dissociative photoionization of carbon monoxide. On the basis of experimental and predicted theoretical results, the mechanisms of photoionization and dissociative photoionization of molecular CO are discussed, and sixteen dissociative photoionization processes are proposed. The equilibrium geometries and harmonic vibrational frequencies of CO molecule, and its parent cation were calculated by using MP2 (full) method. The differences of configurations between them are also discussed on the basis of theoretical calculations. According to our results, the experimental IE of CO molecule, and dissociation energies (E d ) of possible dissociative channels are in reasonable agreement with the calculated values of the proposed photodissociation channels

  2. CW-Laser-Induced Solid-State Reactions in Mixed Micron-Sized Particles of Silicon Monoxide and Titanium Monoxide: Nano-Structured Composite with Visible Light Absorption

    Czech Academy of Sciences Publication Activity Database

    Křenek, T.; Tesař, J.; Kupčík, Jaroslav; Netrvalová, M.; Pola, M.; Jandová, Věra; Pokorná, Dana; Cuřínová, Petra; Bezdička, Petr; Pola, Josef

    2017-01-01

    Roč. 27, č. 6 (2017), s. 1640-1648 ISSN 1574-1443 Institutional support: RVO:61388980 ; RVO:67985858 Keywords : Cw CO2 laser heating * IR laser imaging * Silicon monoxide * Solid state redox reactions * Ti/Si/O composite * Titanium monoxide Subject RIV: CA - Inorganic Chemistry; CI - Industrial Chemistry, Chemical Engineering (UCHP-M) OBOR OECD: Inorganic and nuclear chemistry; Chemical process engineering (UCHP-M) Impact factor: 1.577, year: 2016

  3. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    Science.gov (United States)

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  4. Multiband carbon monoxide laser (2.5 -- 4.0 and 5.0 -- 6.5 micron) pumped by capacitive slab RF discharge

    Science.gov (United States)

    Ionin, Andrey; Kozlov, Andrey; Seleznev, Leonid; Sinitsyn, Dmitry

    2008-10-01

    Overtone lasing and fundamental band tuning was for the first time obtained in a carbon monoxide laser excited by repetitively pulsed capacitive slab RF discharge (81.36 MHz). RF discharge pulse repetition rate was 100--500 Hz. The active volume was 3x30x250 cubic mm. Laser electrodes were cooled down to 120 K. Gas mixture CO:air:He at gas pressure 15 Torr was used. The optical scheme ``frequency selective master oscillator - laser amplifier'' was applied for getting fundamental band tuning. Single line lasing with average power up to several tens of mW was observed on about 100 rotational-vibrational transitions of CO molecule within the spectral range 5.0--6.5 micron. Multiline overtone lasing was observed on about 80 spectral lines within the spectral range 2.5-4.0 micron, with maximum single line average output power 12 mW. The total output power of the slab overtone CO laser came up to 0.35 W, with laser efficiency 0.5 percent. The results of parametric studies of capacitive slab RF discharge in carbon monoxide mixtures, and overtone and fundamental band CO laser characteristics are discussed.

  5. Analysis of the feasibility of an experiment to measure carbon monoxide in the atmosphere. [using remote platform interferometry

    Science.gov (United States)

    Bortner, M. H.; Alyea, F. N.; Grenda, R. N.; Liebling, G. R.; Levy, G. M.

    1973-01-01

    The feasibility of measuring atmospheric carbon monoxide from a remote platform using the correlation interferometry technique was considered. It has been determined that CO data can be obtained with an accuracy of 10 percent using this technique on the first overtone band of CO at 2.3 mu. That band has been found to be much more suitable than the stronger fundamental band at 4.6 mu. Calculations for both wavelengths are presented which illustrate the effects of atmospheric temperature profiles, inversion layers, ground temperature and emissivity, CO profile, reflectivity, and atmospheric pressure. The applicable radiative transfer theory on which these calculations are based is described together with the principles of the technique.

  6. New reduced variant in gadolinium and samarium monoxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Bist, B M.S.; Kumar, J; Srivastava, O N [Banaras Hindu Univ. (India). Dept. of Physics

    1977-01-01

    A new reduced phase has been observed in the thin films of gadolinium and samarium monoxides. This phase results on imparting an annealing treatment to the monoxides and is formed as a result of the creation and ordering of vacancies in the oxygen sublattice. The new phase has been analysed to possess a rhombohedral unit cell with lattice parameters a/sub R/ = a/sub 0/ square root of (3/2) and c/sub R/ = a/sub 0/ square root of 3 (based on hexagonal axes, a/sub 0/ being the lattice parameter of the fundamental zinc blende type unit cell of the monoxide). Based on the proposed structure, the new phase can be assigned the solid state chemical formula RO/sub x/ where R = Gd, Sm and x = 0.66.

  7. First-Principles Investigations on Europium Monoxide

    KAUST Repository

    Wang, Hao

    2011-05-01

    Europium monoxide is both an insulator and a Heisenberg ferromagnet (Tc=69 K). In the present thesis, the author has investigated the electronic structure of different types of EuO by density functional theory. The on-site Coulomb interaction of the localized Eu 4f and 5d electrons, which is wrongly treated in the standard generalized gradient approximation method, is found to be crucial to obtain the correct insulating ground state as observed in experiments. Our results show that the ferromagnetism is stable under pressure, both hydrostatic and uniaxial. For both types of pressure an insulator-metal transition is demonstrated. Moreover, the experimentally observed insulator-metal transition in oxygen deficient and gadolinium-doped EuO is reproduced in our calculations for impurity concentrations of 6.25% and 25%. Furthermore, a 10- layer EuO thin film is theoretically predicted to be an insulator with a narrow band gap of around 0.08 eV, while the Si/EuO interface shows metallic properties with the Si and O 2p as well as Eu 5d bands crossing the Fermi level.

  8. Carbon monoxide may be an important molecule in migraine and other headaches

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Schytz, Henrik W; Hauge, Mette K

    2014-01-01

    INTRODUCTION: Carbon monoxide was previously considered to just be a toxic gas. A wealth of recent information has, however, shown that it is also an important endogenously produced signalling molecule involved in multiple biological processes. Endogenously produced carbon monoxide may thus play...

  9. CARBON MONOXIDE AND THE NERVOUS SYSTEM

    Science.gov (United States)

    Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and there...

  10. Optimization of Treatment Policy for Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    R. N. Akalayev

    2012-01-01

    Full Text Available Objective: to evaluate the efficiency of combination use of hyperbaric oxygenation, succinate-containing solutions, and anti-edematous agents in patients with acute carbon monoxide poisoning. Subjects and methods. The results of treatment were analyzed in 32 patients admitted in 2009—2011 for severe acute carbon monoxide poisoning and a Glasgow coma score of 6—8. The patients were divided into 2 groups: 1 patients whose combination therapy involved hyperbaric oxygenation, Succinasol infusions, and L-lysine-aescinate injections; 2 those who received traditional therapy. All the patients underwent complex clinical, laboratory, and neurophysiologic examinations. Results. Just 24 hours after the combination use of Succinasol and L-lysine-aescinate, Group I patients were observed to have substantially reduced lactate, the content of the latter approached the normal value following 48 hours, which was much below the values in the control group. The similar pattern was observed when endogenous intoxication parameters were examined. During the performed therapy, the level of consciousness and that of intellect according to the MMSE and FAB scales were restored more rapidly in the study group patients than in Group 2. Conclusion. The combination use of hyperbaric oxygenation, the succinate-containing solution Succinasol, and the anti-edematous agent L-lysine-aescinate considerably enhances the efficiency of intensive therapy for acute carbon monoxide poisoning. Key words: carbon monoxide, toxic hypoxic encephalopathy, combination therapy, hyperbaric oxygenation, succinic acid, L-lysine-aescinate.

  11. Carbon Monoxide Exposure in Youth Ice Hockey.

    Science.gov (United States)

    Macnow, Theodore; Mannix, Rebekah; Meehan, William P

    2017-11-01

    To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.

  12. Prenatal MRI fetal lung volumes and percent liver herniation predict pulmonary morbidity in congenital diaphragmatic hernia (CDH).

    Science.gov (United States)

    Zamora, Irving J; Olutoye, Oluyinka O; Cass, Darrell L; Fallon, Sara C; Lazar, David A; Cassady, Christopher I; Mehollin-Ray, Amy R; Welty, Stephen E; Ruano, Rodrigo; Belfort, Michael A; Lee, Timothy C

    2014-05-01

    The purpose of this study was to determine whether prenatal imaging parameters are predictive of postnatal CDH-associated pulmonary morbidity. The records of all neonates with CDH treated from 2004 to 2012 were reviewed. Patients requiring supplemental oxygen at 30 days of life (DOL) were classified as having chronic lung disease (CLD). Fetal MRI-measured observed/expected total fetal lung volume (O/E-TFLV) and percent liver herniation (%LH) were recorded. Receiver operating characteristic (ROC) curves and multivariate regression were applied to assess the prognostic value of O/E-TFLV and %LH for development of CLD. Of 172 neonates with CDH, 108 had fetal MRIs, and survival was 76%. 82% (89/108) were alive at DOL 30, 46 (52%) of whom had CLD. Neonates with CLD had lower mean O/E-TFLV (30 vs.42%; p=0.001) and higher %LH (21.3±2.8 vs.7.1±1.8%; p20% (AUC=0.78; p20% were highly associated with indicators of long-term pulmonary sequelae. On multivariate analysis, %LH was the strongest predictor of CLD in patients with CDH (OR: 10.96, 95%CI: 2.5-48.9, p=0.002). Prenatal measurement of O/E-TFLV and %LH is predictive of CDH pulmonary morbidity and can aid in establishing parental expectations of postnatal outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Catalytic Copolymerization of Ethene and Carbon Monoxide on Nickel Complexes.

    Science.gov (United States)

    Domhöver, Bernd; Kläui, Wolfgang; Kremer-Aach, Andreas; Bell, Ralf; Mootz, Dietrich

    1998-11-16

    Can palladium be replaced by nickel? For the industrial copolymerization of carbon monoxide and ethene a palladium catalyst is used which cannot be recovered-a cheaper procedure would be desirable. The presented complex 1 is the first structurally characterized nickel compound which does not polymerize ethene but a mixture from carbon monoxide and ethene unter mild conditions to give a perfectly alternating polyketone. © 1998 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  14. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Science.gov (United States)

    2010-07-01

    ....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Oxides of nitrogen, carbon monoxide...

  15. Age, smoking habits, heat stress, and their interactive effects with carbon monoxide and peroxyacetyl nitrate on man's aerobic power

    Energy Technology Data Exchange (ETDEWEB)

    Raven, P.B.; Drinkwater, B.L.; Horvath, S.M.; Ruhling, R.O.; Gliner, J.A.; Sutton, J.C.; Bolduan, N.W.

    1972-10-01

    The interactive effects of age, smoking habits, and heat stress with carbon monoxide and peroxyacetyl nitrate inhalation on human aerobic power were examined. The subjects included 16 healthy middle-aged males (40-57 years); nine were nonsmokers and seven were smokers. There was no significant change in maximum aerobic power related to the presence of either air pollutant, although total working time was lowered at a temperature of 25/sup 0/C for subjects breathing 50 ppM CO. Older nonsmokers did show a decrement in maximum aerobic power while breathing 50 ppM CO, while older smokers failed to show any change. This difference, however, was related to the initial carboxyhemoglobin levels of the smokers who, when breathing this level of CO, showed only a 14 percent increase in COHb over the initial level as compared to a 200 percent increase in the nonsmokers. Smoking habits were the most influential factor affecting cardiorespiratory responses to maximal exercise in older men. Regardless of ambient conditions, smokers showed a significantly lower (27 percent) aerobic power than nonsmokers. They were also breathing closer to their maximal breathing capacities throughout the exercise period and showed a higher respiratory exchange ratio. The maximum aerobic power of nonsmokers was only 6 percent less than that of younger nonsmokers working under similar conditions, while the aerobic power of the older smokers was 26 percent lower than that of young smokers (24 years).

  16. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Science.gov (United States)

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  17. On the composition of nonstoichiometric europium monoxide

    International Nuclear Information System (INIS)

    Ignat'eva, N.I.

    1990-01-01

    Consideration is given to results of of investigation into chemical composition, homogeneity region, type of disordering of nonstoichiometric europium monoxide. Precision methods of X-ray diffraction, electron-microscopic, atomic-absorption chemical analysis were used. It is shown that lattice volume reduces with increase of oxygen content in the oxide. For monocrystal of EuO 1.01 composition a=5.146 A. All samples of europium monoxide are characterized by low conductivity. Conductivity value changes by two orders (from 10 -8 to 10 -6 Θ -1 ·cm -1 ) when passing from the sample of stoichiometric composition to maximally disordered one. The disordering is considered according to the type of charged cation vacancies, leading to occurrence of equivalent number of electron defects of positive holes. 4 refs.; 1 tab

  18. Carbon Monoxide Epidemic Among Immigrant Populations: King County, Washington, 2006

    Science.gov (United States)

    Kwan-Gett, Tao; Hampson, Neil B.; Baer, Atar; Shusterman, Dennis; Shandro, Jamie R.; Duchin, Jeffrey S.

    2009-01-01

    Objectives. We investigated an outbreak of carbon monoxide (CO) poisoning after a power outage to determine its extent, identify risk factors, and develop prevention measures. Methods. We reviewed medical records and medical examiner reports of patients with CO poisoning or related symptoms during December 15 to 24, 2006. We grouped patients into households exposed concurrently to a single source of CO. Results. Among 259 patients with CO poisoning, 204 cases were laboratory confirmed, 37 were probable, 10 were suspected, and 8 were fatal. Of 86 households studied, 58% (n = 50) were immigrant households from Africa (n = 21), Asia (n = 15), Latin America (n = 10), and the Middle East (n = 4); 34% (n = 29) were US-born households. One percent of households was European (n = 1), and the origin for 7% (n = 6) was unknown. Charcoal was the most common fuel source used among immigrant households (82%), whereas liquid fuel was predominant among US-born households (34%). Conclusions. Educational campaigns to prevent CO poisoning should consider immigrants’ cultural practices and languages and specifically warn against burning charcoal indoors and incorrect ventilation of gasoline- or propane-powered electric generators. PMID:19608962

  19. Mechanism of obtaining carbon monoxide and hydrogen during brown coal radiolysis. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rustamov, V R; Kurbanov, M A; Dzantiev, B T; Kerimov, V K; Musaeva, P F

    1982-05-01

    This article analyzes effects of gamma radiation on the yield of products of coal gasification: hydrogen and carbon monoxide. Samples of brown coal from the Kansk-Achins basin were treated by gamma radiation with cobalt 60 radiation source. Analyses show that accumulation of hydrogen and carbon monoxide in brown coal under influence of gamma radiation is characterized by a constant rate. Yields of carbon monoxide and hydrogen amount to 0.16 molecule/100 electro volt and 0.21 molecule/electro volt respectively. Reducing radiation dose from 2.5 to 0.7 millirad/h reduces yields of hydrogen and carbon monoxide. Increasing temperature of vacuum brown coal pyrolysis from 200 to 600 C causes decrease of hydrogen yield. Hydrogen yield decrease during temperature increase is caused by a high content of aromatic nuclei in the samples used in the radiolysis. (5 refs.)

  20. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    Science.gov (United States)

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  1. Percent Coverage

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Percent Coverage is a spreadsheet that keeps track of and compares the number of vessels that have departed with and without observers to the numbers of vessels...

  2. Ferromagnetic semiconductor-metal transition in heterostructures of europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias; Kroha, Johann [Physikalisches Institut der Universitaet Bonn (Germany)

    2012-07-01

    Experiments on thin films of electron doped europium monoxide show a simultaneous ferromagnetic semiconductor-metal transition which goes along with a huge drop in resistivity over several orders of magnitude. Therefore, this material is a very promising candidate for spintronics applications. We have developed a theory which correctly predicts the simultaneous phase transition in thin films of electron doped EuO and the increase of the Curie temperature T{sub C} with doping concentration. The origin of the increased T{sub C} lies in the enhanced RKKY interaction between the localized 4f moments of the Eu atoms. Therefore, the phase transition is controlled by the population of the conduction band. We investigate the influence of film thickness and interface effects on the population of the conduction band and on the magnetic and electronic properties of the EuO film.

  3. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Science.gov (United States)

    Kaminaga, Kenichi; Sei, Ryosuke; Hayashi, Kouichi; Happo, Naohisa; Tajiri, Hiroo; Oka, Daichi; Fukumura, Tomoteru; Hasegawa, Tetsuya

    Rare earth sesquioxides like Y2O3 are known as widegap insulators with the highly stable closed shell trivalent rare earth ions. On the other hand, rare earth monoxides such as YO have been recognized as gaseous phase, and only EuO and YbO were thermodynamically stable solid-phase rock salt monoxides. In this study, solid-phase rock salt yttrium monoxide, YO, was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO possesses unusual valence of Y2+ ([Kr] 4d1) . In contrast with Y2O3, YO was narrow gap semiconductor with dark-brown color. The electrical conductivity was tunable from 10-1 to 103 Ω-1 cm-1 by introducing oxygen vacancies as electron donor. Weak antilocalization behavior was observed indicating significant spin-orbit coupling owing to 4 d electron carrier. The absorption spectral shape implies the Mott-Hubbard insulator character of YO. Rare earth monoixdes will be new platform of functional oxides. This work was supported by JST-CREST, the Japan Society for the Promotion of Science (JSPS) with Grant-in-Aid for Scientific Research on Innovative Areas (Nos. 26105002 and 26105006), and Nanotechnology Platform (Project No.12024046) of MEXT, Japan.

  4. Study on the surface oxidation resistance of uranium metal in the atmosphere of carbon monoxide

    International Nuclear Information System (INIS)

    Wang Xiaolin; Fu Yibei; Xie Renshou

    1999-01-01

    The surface reactions of different layers on uranium metal with carbon monoxide at 25, 80 and 200 degree C are studied by X-ray photoelectron spectroscopy (XPS). The experimental results show that the carbon monoxide is adsorbed on the surface oxide layer of uranium and interacted each other. The content of oxygen in the surface oxide and O/U ratio are decreased with increasing the exposure of carbon monoxide to the surface layer. The effect of reduction on the metal surface is more obviously with a higher temperature and increasing of layer thickness. The investigation indicates the uranium metal has resistance to further oxidation in the atmosphere of carbon monoxide

  5. XPS study on the surface reaction of uranium metal with carbon monoxide at 200 degree C

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-12-01

    The surface reaction of uranium metal with carbon monoxide at 200 degree C has been studied by X-ray photoelectron spectroscopy (XPS). The carbon monoxide adsorption on the surface oxide layer resulted in U4f peak shifting to the lower binding energy and the content of oxygen in the oxide is decreased. O/U radio decreases with increasing the exposure of carbon monoxide to the surface layer. The investigation indicated the surface layer of uranium metal was further reduced in the atmosphere of carbon monoxide at high temperature. (3 refs., 5 figs.)

  6. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    Energy Technology Data Exchange (ETDEWEB)

    Inui, Y. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)]. E-mail: inui@eee.tut.ac.jp; Urata, A. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Ito, N. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Nakajima, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Tanaka, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)

    2006-08-15

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide.

  7. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    International Nuclear Information System (INIS)

    Inui, Y.; Urata, A.; Ito, N.; Nakajima, T.; Tanaka, T.

    2006-01-01

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide

  8. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  9. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Science.gov (United States)

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  10. Chemical production from waste carbon monoxide: its potential for energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Rohrmann, C.A.; Schiefelbein, G.F.; Molton, P.M.; Li, C.T.; Elliott, D.C.; Baker, E.G.

    1977-11-01

    Results of a study of the potential for energy conservation by producing chemicals from by-product or waste carbon monoxide (CO) from industrial sources are summarized. Extensive compilations of both industrial sources and uses for carbon monoxide were developed and included. Reviews of carbon monoxide purification and concentration technology and preliminary economic evaluations of carbon monoxide concentration, pipeline transportation and utilization of CO in the synthesis of ammonia and methanol are included. Preliminary technical and economic feasibility studies were made of producing ammonia and methanol from the by-product CO produced by a typical elemental phosphorus plant. Methanol synthesis appears to be more attractive than ammonia synthesis when using CO feedstock because of reduced water gas shift and carbon dioxide removal requirements. The economic studies indicate that methanol synthesis from CO appears to be competitive with conventional technology when the price of natural gas exceeds $0.82/million Btu, while ammonia synthesis from CO is probably not competitive until the price of natural gas exceeds $1.90/million Btu. It is concluded that there appears to be considerable potential for energy conservation in the chemical industry, by collecting CO rather than flaring it, and using it to make major chemicals such as ammonia and methanol.

  11. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    OpenAIRE

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been o...

  12. Lack of the correlation between biochemical effects on rats and blood carboxyhemoglobin concentrations in various conditions of single acute exposure to carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Sokal, J.A.

    1975-01-01

    The relationship between conditions of exposure to carbon monoxide (CO) and biochemical effects was investigated in experiments on rats. The magnitude and the time of biochemical disturbances in the tissues resulting from two different exposures consisting of 1 vol. percent CO for 4 min and 0.4 vol. percent CO for 40 min respectively were compared. In both cases, at the end of exposure the same level of blood carboxyhemoglobin (COHb) (about 50 percent) was reached. The biochemical determinations in the blood (pH, glucose, lactate, pyruvate) and brain tissue (lactate, pyruvate) were carried out immediately after termination of the exposure and after the time periods of restitution. CO exposure resulted in a decreased blood pH, increased level of blood glucose, as well as that of lactate and pyruvate both in blood and brain tissue. These changes were much more pronounced following the longer-lesser exposure than after the shorter-intense one, although blood concentrations of COHb was the same. The observed phenomenon puts some light on the frequently encountered lack of the correlation between COHb level in blood and severity of CO intoxication in clinical practice.

  13. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    Science.gov (United States)

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  14. First principles description of the insulator-metal transition in europium monoxide

    KAUST Repository

    Wang, Hao

    2012-02-01

    Europium monoxide, EuO, is a ferromagnetic insulator. Its electronic structure under pressure and doping is investigated by means of density functional theory. We employ spin polarized electronic structure calculations including onsite electron-electron interaction for the localized Eu 4f and 5d electrons. Our results show that under pressure the ferromagnetism is stable, both for hydrostatic and uniaxial pressure, while the compound undergoes an insulator-metal transition. The insulator-metal transition in O deficient and Gd doped EuO is reproduced for an impurity concentration of 6.25%. A 10 monolayer thick EuO(1 0 0) thin film is predicted to be an insulator with a narrow band gap of 0.08 eV. © 2011 Elsevier B.V. All rights reserved.

  15. Modeling chemisorption kinetics of carbon monoxide on polycrystalline platinum

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, R.G.; Modell, M.; Baddour, R.F.

    1978-04-01

    Seven distinct desorption surface states of carbon monoxide on polycrystalline platinum were detected by deconvoluting temperature-programed desorption spectra of 4-100% carbon monoxide monolayer coverage. The adstates had fixed activation energies of desorption (22.5-32.6 kcal/mole) over the entire coverage range. Rates of formation and populations were derived. The chemisorption was modeled by a Hinshelwood-type expression which allowed for site creation and suggested that adsorbed molecules are sufficiently mobile during desorption heating to fill ordered states of minimum energy and that chemisorption into these states is noncompetitive and determined by the surface. Spectra, diagrams, graphs, tables, and 49 references.

  16. Regional air-quality forecasting for the Pacific Northwest using MOPITT/TERRA assimilated carbon monoxide MOZART-4 forecasts as a near real-time boundary condition

    Directory of Open Access Journals (Sweden)

    F. L. Herron-Thorpe

    2012-06-01

    Full Text Available Results from a regional air quality forecast model, AIRPACT-3, were compared to AIRS carbon monoxide column densities for the spring of 2010 over the Pacific Northwest. AIRPACT-3 column densities showed high correlation (R > 0.9 but were significantly biased (~25% with consistent under-predictions for spring months when there is significant transport from Asia. The AIRPACT-3 CO bias relative to AIRS was eliminated by incorporating dynamic boundary conditions derived from NCAR's MOZART forecasts with assimilated MOPITT carbon monoxide. Changes in ozone-related boundary conditions derived from MOZART forecasts are also discussed and found to affect background levels by ± 10 ppb but not found to significantly affect peak ozone surface concentrations.

  17. Influence of carbon monoxide to the surface layer of uranium metal and its oxides

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-09-01

    The surface structures of uranium metal and triuranium octaoxide (U 3 O 8 ) and the influence of carbon monoxide to the surface layers have been studied by X-ray photoelectron spectroscopy (XPS). After exposure to carbon monoxide, contents of oxygen in the surface oxides of uranium metal and U 3 O 8 are decreased and O/U ratios decrease 7.2%, 8.0% respectively. The investigation indicated the surface layers of uranium metal and its oxides were forbidden to further oxidation in the atmosphere of carbon monoxide. (11 refs., 9 figs., 2 tabs.)

  18. Carbon Monoxide Hazards from Small Gasoline Powered Engines

    Science.gov (United States)

    ... DHHS (NIOSH) Publication No. 96-118 (1996) Describes health effects and current standards and guidelines relating to carbon monoxide, as well as recommendations for workers, employers, and manufacturers regarding small gasoline powered engine ...

  19. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    Science.gov (United States)

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-11-01

    Small-size (carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction.

  20. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker a...

  1. CT and clinical patterns in suicidal carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-12-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications.

  2. The predictive value of MR diffusion weighted imaging on the delayed encephalopathy after carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Xiao Xinlan; Fu Lihui; Xi Weimin; Yin Jianhua; Gong Liangeng; Yuan Aimei; Yang Xinyue; Liu Zhiyong

    2007-01-01

    Objective: To investigate the value of diffusion weighted imaging (DWI)in predicting delayed encephalopathy of the rabbits brain after carbon monoxide (CO)poisoning. Methods: Sixty healthy rabbits were put into self-made poisoning cabinet and were poisoned by inhalation of CO. Aeration of CO was stopped when the rabbits became comatous, and the cabinet was kept airpoof for 6 h. The rabbits underwent MRI before poisoning , at 1 h, 3 d, 5 d, 7 d, 15 d, 30 d ,45 d, and 60 d after poisoning respectively. Axial and sagittal T 2 WI, axial T 1 WI and DWI were performed. In the rabbits that did not show symptoms of delayed encephalopathy, the observation was discontinued on the 60th day. In the rabbit that showed the symptoms, the observation was discontinued on the 30th-45th day. The changing pattern of cortical ADC values before and after CO poisoning was observed and its relationship with delayed encephalopathy was investigated. Results: In the group without delayed encephalopathy (15 rabbits), the ADC value at 1 h after poisoning [(7.58±0.36) x 10 -4 mm 2 /s] decreased significantly compared with the pre- poisoning value [(8.02±0.35) x 10 -4 mm 2 /s] (q=0.4441, P -4 mm 2 /s], and maintained at the same level as pre- poisoning at 60 d after poisoning (P >0.05). In the group with delayed encephalopathy (15 rabbits), the ADC value at 1 h after poisoning [(7.40±0.32) x 10 -4 mm 2 /s] decreased significantly compared with the pre- poisoning value [(8.08± 0.32) x 10 -4 mm 2 /s] (q=0.6728, P -4 mm 2 /s], secondly significantly decreased at 15 d [(7.29±0.93) x 10 -4 mm 2 /s] without further recovery. The ADC value decrease at 15d alter poisoning [(7.29±0.93) x 10 -4 mm 2 /s] was significant compared with the prepoisoning ADC value (q=0.7850, P<0.01). Conclusions: There is a correlation between the decrease of the ADC value and the degree of tissue damage. The decrease of the ADC value in acute stage can predict the delayed encephalopathy. The second significant decrease

  3. Kinetics of heterogeneous catalysis oxidation of carbon monoxide

    International Nuclear Information System (INIS)

    Khawaja, Y.; Sadiq, A.

    1987-10-01

    An irreversible kinetic surface-reaction model, based upon the reaction of carbon monoxide nd oxygen on a catalyst surface is investigated by means of Monte Carlo simulation. The adsorbed molecules/atoms on the surface undergo both first and second order kinetic phase transitions. The first order transition is found to occur at x/sub/co=x/sub/2=0.5255 with an error bar of 0.0003, where x/sub/co is the concentration of carbon monoxide in the gas phase. The time evolution of this catalytic reaction is studied both analytically and by computer simulation. Slightly above x/sub/2, the oxygen coverage relaxation time for the oxygen is found to diverage as the inverse of 3.54 times the absolute of the difference of x/sub/2 and x/sub/co. (orig./A.B.)

  4. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Science.gov (United States)

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  5. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Science.gov (United States)

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  6. Vaporization study on vanadium monoxide and two-phase mixture of vanadium and vanadium monoxide by mass-spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over single phase vanadium monoxide VO 1.022 (s) and the two-phase mixture of vanadium metal (β phase) and vanadium monoxide were measured by mass-spectrometric method in the temperature range of 1,803 ∼ 1,990 and 1,703 ∼ 1,884 K, respectively. The main gas species over both systems were found to be VO(g) and V(g). The vapor pressure of VO(g) over the two-phase mixture of V(s) and VO(s) was a little lower than that over single phase VO(s). The vapor pressure of V(g) over the two-phase mixture was nearly equal to that over single phase. From the vapor pressure data, the enthalpies of vaporization, the enthalpies of formation for VO(g) and V(g) and the dissociation energy of VO(g) were determined. The oxygen partial pressure was calculated as a function of temperature from the vapor pressures of VO(g) and V(g), from which the partial molar enthalpies and entropies of oxygen in both systems were obtained. (author)

  7. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    Science.gov (United States)

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  8. CT and clinical patterns in suicidal carbon monoxide

    International Nuclear Information System (INIS)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-01-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications. (orig.) [de

  9. Bio-Inspired Carbon Monoxide Sensors with Voltage-Activated Sensitivity

    KAUST Repository

    Savagatrup, Suchol

    2017-09-27

    Carbon monoxide (CO) outcompetes oxygen when binding to the iron center of hemeproteins, leading to a reduction in blood oxygen level and acute poisoning. Harvesting the strong specific interaction between CO and the iron porphyrin provides a highly selective and customizable sensor. We report the development of chemiresistive sensors with voltage-activated sensitivity for the detection of CO comprising iron porphyrin and functionalized single-walled carbon nanotubes (F-SWCNTs). Modulation of the gate voltage offers a predicted extra dimension for sensing. Specifically, the sensors show a significant increase in sensitivity toward CO when negative gate voltage is applied. The dosimetric sensors are selective to ppm levels of CO and functional in air. UV/Vis spectroscopy, differential pulse voltammetry, and density functional theory reveal that the in situ reduction of FeIII to FeII enhances the interaction between the F-SWCNTs and CO. Our results illustrate a new mode of sensors wherein redox active recognition units are voltage-activated to give enhanced and highly specific responses.

  10. Percent Wetland Cover

    Data.gov (United States)

    U.S. Environmental Protection Agency — Wetlands act as filters, removing or diminishing the amount of pollutants that enter surface water. Higher values for percent of wetland cover (WETLNDSPCT) may be...

  11. Computation of diatomic molecular spectra for selected transitions of aluminum monoxide, cyanide, diatomic carbon, and titanium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Parigger, Christian G., E-mail: cparigge@tennessee.edu [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Woods, Alexander C.; Surmick, David M.; Gautam, Ghaneshwar; Witte, Michael J. [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Hornkohl, James O. [Hornkohl Consulting, Tullahoma, TN 37388 (United States)

    2015-05-01

    Laser ablation studies with laser-induced breakdown spectroscopy (LIBS) typically emphasize atomic species yet fingerprints from molecular species can occur subsequently or concurrently. In this work, selected molecular transitions of aluminum monixide (AlO), diatomic carbon (C{sub 2}), cyanide (CN), and titanium monoxide (TiO) are accurately computed. Line strength tables are used to describe the radiative transitions of diatomic molecules primarily in the visible, optical region. Details are elaborated of the computational procedure that allows one to utilize diatomic spectra as a predictive and as a diagnostic tool. In order to create a computed spectrum, the procedure requires information regarding the temperature of the diatomic transitions along with other input such as the spectral resolution. When combined with a fitting algorithm to optimize such parameters, this procedure is used to infer information from an experimentally obtained spectrum. Furthermore, the programs and data files are provided for LIBS investigations that also reveal AlO, C{sub 2}, CN, and TiO diatomic spectra. - Highlights: • We present a program for fitting of molecular spectra. • This includes data base for AlO, C{sub 2}, CN, and TiO. • We discuss the details of the program including fitting. • We show computed examples and reference current work.

  12. Environmental tobacco smoke exposure among non-smoking waiters: measurement of expired carbon monoxide levels

    Directory of Open Access Journals (Sweden)

    Ronaldo Laranjeira

    2000-07-01

    Full Text Available CONTEXT: Exposure to environmental tobacco smoke is a health risk that is of concern to patrons and of particular concern to employees of restaurants and bars. OBJECTIVE: To assess environmental tobacco smoke exposure (using expired carbon monoxide levels in non-smoking waiters before and after a normal day's shift and to compare pre-exposure levels with non-smoking medical students. DESIGN: An observational study. SETTING: Restaurants with more than 50 tables or 100 places in São Paulo. SUBJECTS: 100 non-smoking restaurant waiters and 100 non-smoking medical students in São Paulo, Brazil. MAIN MEASUREMENTS: Levels of expired carbon monoxide, measured with a Smokerlyser (Bedfont EC 50 Scientific, before and after a normal day's work. RESULTS: Waiters' pre-exposure expired carbon monoxide levels were similar to those of medical students, but after a mean of 9 hours exposure in the workplace, median levels more than doubled (2.0 ppm vs. 5.0 ppm, P <0.001. Post-exposure carbon monoxide levels were correlated with the number of tables available for smokers (Kendall's tau = 0.2, P <0.0001. CONCLUSIONS: Exposure to environmental tobacco smoke is the most likely explanation for the increase in carbon monoxide levels among these non-smoking waiters. These findings can be used to inform the ongoing public health debate on passive smoking.

  13. Inspiration: One Percent and Rising

    Science.gov (United States)

    Walling, Donovan R.

    2009-01-01

    Inventor Thomas Edison once famously declared, "Genius is one percent inspiration and ninety-nine percent perspiration." If that's the case, then the students the author witnessed at the International Student Media Festival (ISMF) last November in Orlando, Florida, are geniuses and more. The students in the ISMF pre-conference workshop…

  14. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    OpenAIRE

    Metin Uysalol; Ezgi Paslı Uysalol; Gamze Varol Saraçoğlu; Semra Kayaoğlu

    2011-01-01

    Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female) who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide into...

  15. Assessment of exposure to carbon monoxide group of firefighters from fire fighting and rescue units

    Directory of Open Access Journals (Sweden)

    Jadwiga Lembas-Bogaczyk

    2011-03-01

    Full Text Available Firemen threat during fire burning of chemical substances indicated presence of carbon monoxide (CO in all cases. Carbon monoxide causes death of fire. Inhaled through respiratory system, links with hemoglobin, thus blocking transport and distribution of oxygen in the body. This leads to tissue anoxia, which is a direct threat to firefighters’ life. The purpose of this study was to assess the exposure to carbon monoxide of participating firefighters extinguishing fire. Estimation of carbon monoxide quantity absorbed by firefighters was isolated in a group of 40 firefighters from Fire Extinguishing and Rescue Unit of State Fire in Nysa. The study was conducted by measuring carbon monoxide in exhaled air. For measurement of carbon monoxide concentration in exhaled air Micro CO meter was used. Results were demonstrated separately for nonsmokers (n425 and smokers (n415. Mean COHb[%] levels in nonsmokers, measured prior the rescue action was 0,3950,3% and increased statistically significant after the action to 0,6150,34%, while in the group smokers, this level was 2,1750,64% before the action and increased insignificantly after the action to 2,3350,63%. The average COHb level in the same groups before and after exercise, was respectively: for nonsmokers prior to exercise was 0,4850,28% and after exercise decreased statistically significant to 0,3050,27%. In the group of smokers before exercise was 2,2350,61% and decreased statistically significant up to 1,5450,71%. It was no difference between the group of age and time of employment.

  16. Investigation of Carbon Monoxide Adsorption on Cationic Gold- Palladium Clusters

    Science.gov (United States)

    Chen, Yang-Mei; Kuang, Xiao-Yu; Sheng, Xiao-Wei; Wang, Huai-Qian; Shao, Peng; Zhong, Min-Ming

    2013-11-01

    Density functional calculations have been performed for the carbon monoxide molecule adsorption on AunPd+m(n+m ≤ 6) clusters. In the process of CO adsorption, small Au clusters and Pd clusters tend to be an Au atom and three Pd atoms adsorption, respectively. For the mixed Au-Pd clusters, an Au atom, a Pd atom, two atoms consisted of an Au atom and a Pd atom, two Pd atoms, and three Pd atoms adsorption structures are displayed. The highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) gaps and natural bond orbital charge population are calculated. Moreover, CO adsorption energy, CO stretching frequency, and CO bond length (upon adsorption) are also analysed in detail. The results predict that the adsorption strength of Au clusters with CO and the C-O vibration strength is enhanced and reduced after doping of Pd in the AunPdmCO+ complexes, respectively

  17. Study on the influence of carbon monoxide to the surface oxide layer of uranium metal

    International Nuclear Information System (INIS)

    Wang Xiaolin; Duan Rongliang; Fu Yibei; Xie Renshou; Zuo Changming; Zhao Chunpei; Chen Hong

    1997-01-01

    The influence of carbon monoxide to the surface oxide layer of uranium metal has been studied by X-ray photoelectron spectroscopy (XPS) and gas chromatography (GC). Carbon monoxide adsorption on the oxide layer resulted in U4f peak shifting to the lower binding energy. The content of oxygen in the oxide is decreased and the atomic ratio (O/U) is decreased by 7.2%. The amount of carbon dioxide in the atmosphere after the surface reaction is increased by 11.0%. The investigation indicates that the surface layer can prevent the further oxidation uranium metal in the atmosphere of carbon monoxide

  18. Production of Ethylene and Carbon Monoxide by Microorganisms

    Science.gov (United States)

    T. H. Filer; L. R. Brown; S. Brown-Sarobot; S. Martin

    1984-01-01

    Various quantities of ethylene and carbon monoxide were produced on PDA by Fusicladium effusum, Pestilotia nucicola, Alternaria tenuis, and Fusarium oxysporum subcultured from diseased pecan shucks. Repeated subculturing of these fungi on potato dextrose broth supplemented with iron powder produced ethylene. The production of...

  19. Ambient carbon monoxide and cardiovascular mortality: a nationwide time-series analysis in 272 cities in China.

    Science.gov (United States)

    Liu, Cong; Yin, Peng; Chen, Renjie; Meng, Xia; Wang, Lijun; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Kan, Haidong; Zhou, Maigeng

    2018-01-01

    Evidence of the acute health effects of ambient carbon monoxide air pollution in developing countries is scarce and mixed. We aimed to evaluate short-term associations between carbon monoxide and daily cardiovascular disease mortality in China. We did a nationwide time-series analysis in 272 major cities in China from January, 2013, to December, 2015. We extracted daily cardiovascular disease mortality data from China's Disease Surveillance Points system. Data on daily carbon monoxide concentrations for each city were obtained from the National Urban Air Quality Real-time Publishing Platform. City-specific associations between carbon monoxide concentrations and daily mortality from cardiovascular disease, coronary heart disease, and stroke were estimated with over-dispersed generalised linear models. Bayesian hierarchical models were used to obtain national and regional average associations. Exposure-response association curves and potential effect modifiers were evaluated. Two-pollutant models were fit to evaluate the robustness of the effects of carbon monoxide on cardiovascular mortality. The average annual mean carbon monoxide concentration in these cities from 2013 to 2015 was 1·20 mg/m 3 , ranging from 0·43 mg/m 3 to 2·45 mg/m 3 . For a 1 mg/m 3 increase in average carbon monoxide concentrations on the present day and previous day (lag 0-1), we observed significant increments in mortality of 1·12% (95% posterior interval [PI] 0·42-1·83) from cardiovascular disease, 1·75% (0·85-2·66) from coronary heart disease, and 0·88% (0·07-1·69) from stroke. These associations did not vary substantially by city, region, and demographic characteristics (age, sex, and level of education), and the associations for cardiovascular disease and coronary heart disease were robust to the adjustment of criteria co-pollutants. We did not find a threshold below which carbon monoxide exposure had no effect on cardiovascular disease mortality. This analysis is, to our

  20. Optimization of mass flow rate in RGTT200K coolant purification for Carbon Monoxide conversion process

    International Nuclear Information System (INIS)

    Sumijanto; Sriyono

    2016-01-01

    Carbon monoxide is a species that is difficult to be separated from the reactor coolant helium because it has a relatively small molecular size. So it needs a process of conversion from carbon monoxide to carbondioxide. The rate of conversion of carbon monoxide in the purification system is influenced by several parameters including concentration, temperature and mass flow rate. In this research, optimization of the mass flow rate in coolant purification of RGTT200K for carbon monoxide conversion process was done. Optimization is carried out by using software Super Pro Designer. The rate of reduction of reactant species, the growth rate between the species and the species products in the conversion reactions equilibrium were analyzed to derive the mass flow rate optimization of purification for carbon monoxide conversion process. The purpose of this study is to find the mass flow rate of purification for the preparation of the basic design of the RGTT200K coolant helium purification system. The analysis showed that the helium mass flow rate of 0.6 kg/second resulted in an un optimal conversion process. The optimal conversion process was reached at a mass flow rate of 1.2 kg/second. A flow rate of 3.6 kg/second – 12 kg/second resulted in an ineffective process. For supporting the basic design of the RGTT200K helium purification system, the mass flow rate for carbon monoxide conversion process is suggested to be 1.2 kg/second. (author)

  1. Cardiological aspects of carbon monoxide poisoning.

    Science.gov (United States)

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  2. Effect of N-Acetylcysteine in Protecting from Simultaneous Noise and Carbon Monoxide Induced Hair Cell Loss

    Directory of Open Access Journals (Sweden)

    Akram Pourbakht

    2011-06-01

    Full Text Available Background and Aim: N-acetylcysteine, a glutathione precursor and reactive oxygen species scavenger, is reported to be effective in reducing noise-induced hearing loss. Many workers in industry are exposed simultaneously to noise and chemical pollutants such as carbon monoxide. We investigated effectiveness of N-acetylcysteine in protecting the cochlea from simultaneous noise and carbon monoxide damages.Methods: Twelve rabbits were exposed simeltaneously to 100 dB sound pressure level of broad band noise and carbon monoxide 8 hours a day for 5 days. One hour before exposure, experimental group received 325 mg/kg of N-acetylcysteine while normal saline was administered for the control group. The protective effect of N-acetylcysteine was evaluated 3 weeks after exposure by histological assessment of the hair cells.Results: Simultaneous exposure to noise and carbon monoxide resulted in a considerable damage to the outer hair cells; however, the inner hair cells and the pillar cells remained intact. Use of N-acetylcysteine in the experimental group significantly reduced the extent of outer hair cell loss.Conclusion: N-acetylcysteine attenuates simultaneous noise and carbon monoxide induced hair cell damage in rabbits.

  3. Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial.

    Science.gov (United States)

    Ocak, Tarik; Tekin, Erdal; Basturk, Mustafa; Duran, Arif; Serinken, Mustafa; Emet, Mucahit

    2016-11-01

    There is a lack of specificity of the analgesic agents used to treat headache and underlying acute carbon monoxide poisoning. To compare effectiveness of "oxygen alone" vs "metoclopramide plus oxygen" vs "metamizole plus oxygen" therapy in treating carbon monoxide-induced headache. A prospective, multicenter, double-blind, controlled trial. Three emergency departments in Turkey. Adult carbon monoxide poisoning patients with headache. A total of 117 carbon monoxide-intoxicated patients with headache were randomized into 3 groups and assessed at baseline, 30 minutes, 90 minutes, and 4 hours. The primary outcome was patient-reported improvement rates for headache. Secondary end points included nausea, need for rescue medication during treatment, and reduction in carboxyhemoglobin levels. During observation, there was no statistical difference between drug type and visual analog scale score change at 30 minutes, 90 minutes, or 4 hours, for either headache or nausea. No rescue medication was needed during the study period. The reduction in carboxyhemoglobin levels did not differ among the 3 groups. The use of "oxygen alone" is as efficacious as "oxygen plus metoclopramide" or "oxygen plus metamizole sodium" in the treatment of carbon monoxide-induced headache. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. A model for growth of beta-phase particles in zirconium-2.5 wt percent niobium

    International Nuclear Information System (INIS)

    Chow, C.K.; Liner, Y.; Rigby, G.L.

    1984-08-01

    The kinetics of the α → β phase change in Zr-2.5 percent Nb pressure-tube material at constant temperature have been studied. The volume-fraction change of the β phase due to diffusion in an infinite α-phase matrix was considered, and a mathematical model with a numerical solution was developed to predict the transient spherical growth of the β-phase region. This model has been applied to Zr-2.5 wt percent Nb, and the calculated results compared to experiment

  5. Cyclic process for producing methane from carbon monoxide with heat removal

    Science.gov (United States)

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  6. Digit and letter alexia in carbon monoxide poisoning

    Institute of Scientific and Technical Information of China (English)

    Qingyu Shen; Xiaoming Rong; Rui Pan; Ying Peng; Wei Peng; Yamei Tang

    2012-01-01

    This study examined a 24-year-old patient with delayed encephalopathy, who was admitted to hospital with complaints of headache and visual impairment 1 week after acute carbon monoxide poisoning. The results of a visual field assessment, electroencephalography and head magnetic resonance imaging indicated damage to the cerebral cortex. After a 2-week treatment period, the patient had recovered from the visual impairment, but exhibited digit- and letter-reading difficulty. The Chinese aphasia battery and the number and letter battery supplement were conducted. The results revealed that the patient exhibited digit and letter alexia, while the ability to read Chinese characters was preserved. In contrast, the patient exhibited a deficit in Chinese character writing, while number and letter writing remained intact. Following treatment, reading and writing ability was improved and electroencephalographic abnormalities were ameliorated. Overall, our experimental findings demonstrated that delayed encephalopathy following acute carbon monoxide poisoning was characterized by digit and letter alexia.

  7. The indigenous Sea Gypsy divers of Thailand's west coast: measurement of carbon monoxide in the breathing air.

    Science.gov (United States)

    Gold, D; Geater, A; Aiyarak, S; Juengpraert, W

    1999-07-01

    Approximately 400 indigenous divers live and work on Thailand's west coast. They dive with surface supplied air from primitive compressor units mounted on open boats which measure from seven to 11 meters in length. It was suspected that carbon monoxide was present in the breathing air of at least the gasoline-driven compressor units. To determine the presence of carbon monoxide gas in the breathing air, compressed air from the compressor was pumped through the diver air supply hose through a plenum (monitoring) chamber established on the boat. After a compressor warm-up of 15 minutes, the diving air was measured with the boat at eight different bearings to the wind, each 45 degrees apart at intervals of five minutes. Three of the four gasoline-driven compressor units tested showed presence of carbon monoxide in the breathing air. One diesel-driven unit showed a very low concentration of carbon monoxide (3-4 ppm) and six diesel-driven units showed no detectable carbon monoxide. Although not tested, diesel exhaust emissions could also enter the breathing air by the same route. A locally made modification to the compressor air intake was designed and successfully tested on one gasoline-driven compressor unit. An information sheet on the hazards of carbon monoxide as well as on the modification has been developed for distribution among the villages.

  8. Ethylene and Carbon Monoxide Production by Septoria musiva

    Science.gov (United States)

    S. Brown-Skrobot; L. R. Brown; T. H. Filer

    1984-01-01

    An investigation into the mechanism by which Septoria musiva causes the premature defoliation of cottonwood trees was undertaken. Gas-chromatograpic analysis of the atmosphere overlying the original culture indicated that this fungus produced significant quantities of ethylene and carbon monoxide. Subcultures failed to produce either gas on a variety...

  9. Pathways and bioenergetics of anaerobic carbon monoxide fermentation

    NARCIS (Netherlands)

    Diender, Martijn; Stams, Fons; Machado de Sousa, Diana

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the

  10. Accidental carbon monoxide poisoning during yagya for faith healing--a case report.

    Science.gov (United States)

    Behera, C; Millo, T M; Jaiswal, A; Dogra, T D

    2013-03-01

    A 20-year-old female and a 45-year-old male were found lying dead on the floor with frothand vomitus stain present over mouth, nose and face in a closed room. An earthen bowl with incomplete burnt woods, flowers, food materials, agarbati, etc, was also found lying near the body of the two deceased. The cause of death, established by autopsy and toxicological examination was carbon monoxide poisoning in both victims. The source of carbon monoxide was incomplete burnt woods used for yagya during puja (a faith healing practice) for bearing children.

  11. [Carbon monoxide poisoning by a heating system].

    Science.gov (United States)

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  12. Absorption of nicotine and carbon monoxide from passive smoking under natural conditions of exposure.

    Science.gov (United States)

    Jarvis, M J; Russell, M A; Feyerabend, C

    1983-01-01

    Seven non-smokers were exposed to tobacco smoke under natural conditions for two hours in a public house. Measures of nicotine and cotinine in plasma, saliva, and urine and expired air carbon monoxide all showed reliable increases. The concentrations of carbon monoxide and nicotine after exposure averaged 15.7% and 7.5% respectively of the values found in heavy smokers. Although the increase in expired air carbon monoxide of 5.9 ppm was similar to increases in smokers after a single cigarette, the amount of nicotine absorbed was between a tenth and a third of the amount taken in from one cigarette. Since this represented a relatively extreme acute natural exposure, any health risks of passive smoking probably depend less on quantitative factors than on qualitative differences between sidestream and mainstream smoke. PMID:6648864

  13. CT of the brain in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Ohno, Masato; Uchino, Akira; Hayashi, Kazuji; Nakata, Hajime.

    1988-01-01

    Cerebral computed tomographic (CT) findings of acute carbon monoxide (Co) poisoning were analized in thirty-six cases treated with hyperbraric oxygen therapy and their relationship with prognosis was evaluated. The cases were classified into there groups, early stage, interval form, and non-interval form groups. In all groups, the initial abnormality was low density areas presumably due to edema, demyelination and/or softening. It was seen in the globus pallidus and/or white matter. Following these initial changes, cerebral hemorrhage, ventricular dilatation, and cerebral atrophy developed in a few cases. The frequency of abnormal CT findings was higher in the interval form group (85 %) or non-interval group (83 %) than the early stage group (41 %). The prognosis was good in most cases with normal CT findings. The possibility of recovery diminished in the patients with abnormal CT findings. The prognosis was particularly poor in cases showing abnormality both in globus pallidus and white matter. We conclude that CT is useful not only for detecting the pathologic change but also for predicting the prognosis of the patient with acute Co poisoning. (author)

  14. Does One Know the Properties of a MICE Solid or Liquid Absorber to Better than 0.3 Percent?

    International Nuclear Information System (INIS)

    Green, Michael A.; Yang, Stephanie Q.

    2006-01-01

    This report discusses the report discusses whether the MICE absorbers can be characterized to ±0.3 percent, so that one predict absorber ionization cooling within the absorber. This report shows that most solid absorbers can be characterized to much better than ±0.3 percent. The two issues that dominate the characterization of the liquid cryogen absorbers are the dimensions of the liquid in the vessel and the density of the cryogenic liquid. The thickness of the window also plays a role. This report will show that a liquid hydrogen absorber can be characterized to better than ±0.3 percent, but a liquid helium absorber cannot be characterized to better and ±1 percent

  15. An operando FTIR spectroscopic and kinetic study of carbon monoxide pressure influence on rhodium-catalyzed olefin hydroformylation.

    Science.gov (United States)

    Kubis, Christoph; Sawall, Mathias; Block, Axel; Neymeyr, Klaus; Ludwig, Ralf; Börner, Armin; Selent, Detlef

    2014-09-08

    The influence of carbon monoxide concentration on the kinetics of the hydroformylation of 3,3-dimethyl-1-butene with a phosphite-modified rhodium catalyst has been studied for the pressure range p(CO)=0.20-3.83 MPa. Highly resolved time-dependent concentration profiles of the organometallic intermediates were derived from IR spectroscopic data collected in situ for the entire olefin-conversion range. The dynamics of the catalyst and organic components are described by enzyme-type kinetics with competitive and uncompetitive inhibition reactions involving carbon monoxide taken into account. Saturation of the alkyl-rhodium intermediates with carbon monoxide as a cosubstrate occurs between 1.5 and 2 MPa of carbon monoxide pressure, which brings about a convergence of aldehyde regioselectivity. Hydrogenolysis of the acyl intermediate is fast at 30 °C and low pressure of p(CO)=0.2 MPa, but is of minus first order with respect to the solution concentration of carbon monoxide. Resting 18-electron hydrido and acyl complexes that correspond to early and late rate-determining states, respectively, coexist as long as the conversion of the substrate is not complete. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    Science.gov (United States)

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  17. Pulmonary function vascular index predicts prognosis in idiopathic interstitial pneumonia

    NARCIS (Netherlands)

    Corte, Tamera J.; Wort, Stephen J.; MacDonald, Peter S.; Edey, Anthony; Hansell, David M.; Renzoni, Elisabetta; Maher, Toby M.; Nicholson, Andrew G.; Bandula, Steven; Bresser, Paul; Wells, Athol U.

    2012-01-01

    Background and objective: Pulmonary hypertension (PH) is associated with increased mortality in fibrotic idiopathic interstitial pneumonia (IIP). We hypothesize that baseline KCO (diffusing capacity of carbon monoxide/alveolar volume) and 6-month decline in KCO reflect PH, thus predicting mortality

  18. Acute wood or coal exposure with carbon monoxide intoxication induces sister chromatid exchange

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, S.; Vatansever, S.; Cefle, K.; Palanduz, S.; Guler, K.; Erten, N.; Erk, O.; Karan, M.A.; Tascioglu, C. [University of Istanbul, Istanbul (Turkey). Istanbul Faculty of Medicine

    2002-07-01

    The object of this study was to investigate the genotoxic effect of acute overexposure to combustion products originating from coal or wood stoves in patients presenting with acute carbon monoxide intoxication. The authors analyzed the frequency of sister chromatid exchange and the carboxyhemoglobin concentration in 20 consecutive patients without a history of smoking or drug use who had been treated in the Emergency Care Unit of Istanbul Medical Faculty due to acute carbon monoxide intoxication. All of these cases were domestic accidents due to dysfunctioning coal or wood stoves. The results were compared with a control group of 20 nonsmoking, nondrug-using healthy individuals matched for age, sex, and absence of other chemical exposure. It was concluded that acute exposure to combustion products of wood or coal is genotoxic to DNA. Potential causes of genotoxicity include known mutagenic compounds present in coal or wood smoke and ash, oxygen radicals formed during combustion, as well as hypoxic and reperfusion injury mechanisms initiated by carbon monoxide intoxication.

  19. Mixing ratios of carbon monoxide in the troposphere

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Steele, L.P. (Univ. of Colorado, Boulder (United States)); Tans, P.P. (NOAA, Boulder, CO (United States))

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  20. Beyond Marbles: Percent Change and Social Justice

    Science.gov (United States)

    Denny, Flannery

    2013-01-01

    In the author's eighth year of teaching, she hit a wall teaching percent change. Percent change is one of the few calculations taught in math classes that shows up regularly in the media, and one that she often does in her head to make sense of the world around her. Despite this, she had been teaching percent change using textbook problems about…

  1. Influence of cation size and surface coverage upon the infrared spectrum of carbon monoxide

    OpenAIRE

    Huang, Jimin

    1991-01-01

    Adsorbed carbon monoxide is utilized as a double layer probe molecule because of its strong absorption in infrared region and because of the high sensitivity of the carbon-oxygen bond to changes in the environment local to the electrode surface. Potential Difference Infrared Spectroscopy was used to investigate the structural behavior of CO adsorbed on a platinum electrode. Carbon monoxide was found to be exclusively linear-bonded on platinum electrode in the presence of tetran...

  2. Percent Wetland Cover (Future)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Wetlands act as filters, removing or diminishing the amount of pollutants that enter surface water. Higher values for percent of wetland cover (WETLNDSPCT) may be...

  3. Characteristics of exogenous carbon monoxide deliveries

    Directory of Open Access Journals (Sweden)

    Hui-jun Hu

    2016-01-01

    Full Text Available Carbon monoxide (CO has long been considered an environmental pollutant and a poison. Exogenous exposure to amounts of CO beyond the physiologic level of the body can result in a protective or adaptive response. However, as a gasotransmitter, endogenous CO is important for multiple physiologic functions. To date, at least seven distinct methods of delivering CO have been utilized in animal and clinical studies. In this mini-review, we summarize the exogenous CO delivery methods and compare their advantages and disadvantages.

  4. Carbon monoxide oxidation using Zn-Cu-Ti hydrotalcite-derived ...

    Indian Academy of Sciences (India)

    Multioxide catalysts of zinc, copper and titanium with different ratios obtained from layered double hydroxide (LDH) precursors were used in the oxidation of carbon monoxide. The catalysts were characterized by energy-dispersive X-ray spectrometry, X-ray diffraction, thermal analyses (TG, DTG and DTA) and scanning ...

  5. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    Science.gov (United States)

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  6. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008; Campagne de prevention des intoxications au monoxyde de carbone : automne-hiver 2007-2008

    Energy Technology Data Exchange (ETDEWEB)

    Lefebvre, B.; Chabot, L.; Gratton, J. [Direction de sante publique de Montreal, Montreal, PQ (Canada); Lacoursiere, D. [Quebec Ministere de la Sante et des Services sociaux du Quebec, Quebec, PQ (Canada)

    2009-07-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  7. Sensorineural Hearing Loss following Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Joseph P. Pillion

    2012-01-01

    Full Text Available A case study is presented of a 17-year-old male who sustained an anoxic brain injury and sensorineural hearing loss secondary to carbon monoxide poisoning. Audiological data is presented showing a slightly asymmetrical hearing loss of sensorineural origin and mild-to-severe degree for both ears. Word recognition performance was fair to poor bilaterally for speech presented at normal conversational levels in quiet. Management considerations of the hearing loss are discussed.

  8. Cumulative exposure to carbon monoxide during the day

    Energy Technology Data Exchange (ETDEWEB)

    Joumard, R. (INRETS, 69 - Bron (FR))

    The carbon monoxide, CO, has the advantage of being very easily and accurately measured under various conditions. In addition, it allows the translation of CO concentrations into their biological effects. The cumulative CO exposure should be considered according to current environment conditions during a given period of life, e.g. the day. In addition, the translation of concentrations and exposure times of CO fixed on blood haemoglobine (carboxyhaemoglobine) depends on physiological factors such as age, size, sex, or physical activity. This paper gives some examples of CO exposure translated into curves of carboxyhaemoglobine: case of 92 persons whose schedule was studied in details, of customs officers whose exposure was measured during one week, or other theoretical cases. In all the cases studied, smoking is by far the first factor of pollution by carbon monoxide. If not considering this case, the CO contents observed are preoccupying for sensitive subjects (in particular children) only in very rare cases. Furthermore, this approach allows the assessment of maximal allowable concentrations during specific exposures (work, e.g. in a tunnel) by integrating them into normal life conditions and population current exposure.

  9. Effects of chronic carbon monoxide exposure on fetal growth and development in mice

    Directory of Open Access Journals (Sweden)

    Venditti Carolina C

    2011-12-01

    Full Text Available Abstract Background Carbon monoxide (CO is produced endogenously, and can also be acquired from many exogenous sources: ie. cigarette smoking, automobile exhaust. Although toxic at high levels, low level production or exposure lends to normal physiologic functions: smooth muscle cell relaxation, control of vascular tone, platelet aggregation, anti- inflammatory and anti-apoptotic events. In pregnancy, it is unclear at what level maternal CO exposure becomes toxic to the fetus. In this study, we hypothesized that CO would be embryotoxic, and we sought to determine at what level of chronic CO exposure in pregnancy embryo/fetotoxic effects are observed. Methods Pregnant CD1 mice were exposed to continuous levels of CO (0 to 400 ppm from conception to gestation day 17. The effect on fetal/placental growth and development, and fetal/maternal CO concentrations were determined. Results Maternal and fetal CO blood concentrations ranged from 1.12- 15.6 percent carboxyhemoglobin (%COHb and 1.0- 28.6%COHb, respectively. No significant difference was observed in placental histological morphology or in placental mass with any CO exposure. At 400 ppm CO vs. control, decreased litter size and fetal mass (p Conclusions Exposure to levels at or below 300 ppm CO throughout pregnancy has little demonstrable effect on fetal growth and development in the mouse.

  10. A Conceptual Model for Solving Percent Problems.

    Science.gov (United States)

    Bennett, Albert B., Jr.; Nelson, L. Ted

    1994-01-01

    Presents an alternative method to teaching percent problems which uses a 10x10 grid to help students visualize percents. Offers a means of representing information and suggests different approaches for finding solutions. Includes reproducible student worksheet. (MKR)

  11. The Algebra of the Cumulative Percent Operation.

    Science.gov (United States)

    Berry, Andrew J.

    2002-01-01

    Discusses how to help students avoid some pervasive reasoning errors in solving cumulative percent problems. Discusses the meaning of ."%+b%." the additive inverse of ."%." and other useful applications. Emphasizes the operational aspect of the cumulative percent concept. (KHR)

  12. Pathology of carbon monoxide poisoning in two cats.

    Science.gov (United States)

    Sobhakumari, Arya; Poppenga, Robert H; Pesavento, J Brad; Uzal, Francisco A

    2018-03-05

    Carbon monoxide (CO), a common cause of poisoning in human beings has also been implicated in the death of animals. Though there are multiple studies on CO poisoning and relevant lethal blood COHb concentrations in humans, there are no reliable reports of diagnostic lethal carboxyhemoglobin percentage of saturation (COHb%) in cats. Additionally, due to shared housing environments, exposures to companion animals can be a surrogate for lethal exposures in human beings and provide valuable information in concurrent forensic investigations. Two adult Singapura brown ticked cats were submitted to the California Animal Health and Food Safety Laboratory (CAHFS) for necropsy and diagnostic work-up. These animals were found dead along with their two deceased owners. Similar lesions were observed in both cats. At necropsy, gross lesions consisted of multifocal, large, irregular, bright red spots on the skin of the abdomen and the inner surface of ear pinnae, bright red muscles and blood. The carcasses, and tissues fixed in formalin retained the bright red discoloration for up to two weeks. Microscopic lesions included diffuse pulmonary congestion and edema, and multifocal intense basophilia of cardiomyocytes mostly affecting whole fibers or occasionally a portion of the fiber. Based on the clinical history,gross and microscopic changes, cyanide or carbon monoxide poisoning was suspected. Blood samples analyzed for carbon monoxide showed 57 and 41% carboxyhemoglobin COHb%. Muscle samples were negative for cyanide. There are no established reference values for lethal COHb concentration in cats. The COHb % values detected in this case which fell within the lethal range reported for other species, along with the gross lesions and unique histological findings in the heart suggest a helpful criteria for diagnosis of CO intoxication associated death in cats. This case demonstrates that since pets share the same environment as human beings and often are a part of their activities

  13. RARE ISOTOPIC SPECIES OF SULFUR MONOXIDE: THE ROTATIONAL SPECTRUM IN THE THz REGION

    Energy Technology Data Exchange (ETDEWEB)

    Lattanzi, Valerio; Cazzoli, Gabriele; Puzzarini, Cristina, E-mail: lattanzi@mpe.mpg.de [Dipartimento di Chimica “Giacomo Ciamician,” Università di Bologna, Via Selmi 2, I-40126 Bologna (Italy)

    2015-11-01

    Many sulfur-bearing species have been detected in different astronomical environments and have allowed us to derive important information about the chemical and physical composition of interstellar regions. In particular, these species have also been shown to trace and probe hot-core environment time evolution. Among the most prominent sulfur-bearing molecules is SO, the sulfur monoxide radical, one of the more ubiquitous and abundant, which is also observed in its isotopic substituted species such as {sup 34}SO and S{sup 18}O. Due to the importance of this simple diatomic system, and in order to face the challenge of modern radioastronomical facilities, an extension to the THz range of the rare isotopologues of sulfur monoxide has been performed. High-resolution rotational molecular spectroscopy has been employed to extend the available data set of four isotopic species, SO, {sup 34}SO, S{sup 17}O, and S{sup 18}O, up to the 1.5 THz region. The frequency coverage and spectral resolution of our measurements allowed a better constraint of the molecular constants of the four species considered, specifically focusing on the two oxygen-substituted isotopologues. Our measurements were also employed in an isotopically invariant fit including all of the available pure rotational and ro-vibrational transitions for all of the SO isotopologues, thus enabling accurate predictions of the rotational transitions at higher frequencies. We also provide comparisons with recent works performed on the same system, demonstrating the quality of our experiment and the improvement of the data sets for all of the species considered. Transition frequencies for this system can now be used with confidence by the astronomical community well into the THz spectral region.

  14. Verification tests for GRAD, a computer program to predict nonuniform deformation and failure of Zr-2.5 wt percent Nb pressure tubes during a postulated loss-of-coolant accident

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.; Godin, D.P.

    1985-03-01

    During a postulated loss-of-coolant accident in a CANDU reactor, the temperature of the pressure tubes could rise sufficiently so that ballooning could occur. It is also likely that there would be a variation in temperature around the tube circumference, causing the deformation to be nonuniform. Since the deformation of the pressure tube controls how the core heat is transferred to the surrounding moderator, which is a large heat sink, a computer program, GRAD, has been developed to predict this nonuniform deformation. Numerous biaxial creep tests were done, where the temperature of internally pressurized sections of Zr-2.5 wt percent Nb pressure tubes were ramped to check the ability of GRAD to predict the resulting nonuniform deformation and possible tube failure. GRAD was successful in predicting the average transverse creep strain observed during the tests and the local transverse creep strain at the end of the tests. GRAD was also able to predict the failure time and average transverse creep strain at failure for all the specimens that failed

  15. Spectroscopic investigations of high-power laser-induced dielectric breakdown in gas mixtures containing carbon monoxide.

    Science.gov (United States)

    Civis, Svatopluk; Babánková, Dagmar; Cihelka, Jaroslav; Sazama, Petr; Juha, Libor

    2008-08-07

    Large-scale plasma was created in gas mixtures containing carbon monoxide by high-power laser-induced dielectric breakdown (LIDB). The composition of the mixtures used corresponded to a cometary and/or meteoritic impact into the Earth's early atmosphere. A multiple-centimeter-sized fireball was created by focusing a single 85 J, 450 ps near-infrared laser pulse into the center of a 15 L gas cell. The excited reaction intermediates that formed in various stages of the LIDB plasma chemical evolution were investigated by optical emission spectroscopy (OES) with temporal resolution. Special attention was paid to any OES signs of molecular ions. However, carbon monoxide cations were registered only if their production was enhanced by Penning ionization, i.e., excess He was added to the CO. The chemical consequences of laser-produced plasma generation in a CO-N 2-H 2O mixture were investigated using high resolution Fourier-transform infrared absorption spectroscopy (FTIR) and gas chromatography (GC). Several simple inorganic and organic compounds were identified in the reaction mixture exposed to ten laser sparks. H 2 (18)O was used to avoid possible contamination. The large laser spark triggered more complex reactivity originating in carbon monoxide than expected, when taking into account the strong triple bond of carbon monoxide causing typically inefficient dissociation of this molecule in electrical discharges.

  16. Carbon Monoxide Poisoning: Death on Mount McKinley,

    Science.gov (United States)

    1987-05-08

    Additionally, studies by Astrup(5) and Thomas(6) have reported decreased erythrocytic 2, 3- diphosphoglycerate (2, 3-DPG) concentrations with acute...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia .(9...Astrup P: Intraerythrocytic 2,3- diphosphoglycerate and carbon monoxide exposure. Ann NY Acad Sci 1970;174:252-254. 6. Thomas MF, Penny DG: Hematologic

  17. Natural clinoptilolite exchanged with iron: characterization and catalytic activity in nitrogen monoxide reduction

    Directory of Open Access Journals (Sweden)

    Daria Tito-Ferro

    2016-12-01

    Full Text Available The aim of this work was to characterize the natural clinoptilolite from Tasajeras deposit, Cuba, modified by hydrothermal ion-exchange with solutions of iron (II sulfate and iron (III nitrate in acid medium. Besides this, its catalytic activity to reduce nitrogen monoxide with carbon monoxide/propene in the presence of oxygen was evaluated. The characterization was performed by Mössbauer and UV-Vis diffuse reflectance spectroscopies and adsorption measurements. The obtained results lead to conclude that in exchanged samples, incorporated divalent and trivalent irons are found in octahedral coordination. Both irons should be mainly in cationic extra-framework positions inside clinoptilolite channels as charge compensating cations, and also as iron oxy-hydroxides resulting from limited hydrolysis of these cations. The iron (III exchanged samples has a larger amount of iron oxy-hydroxides agglomerates. The iron (II exchanged samples have additionally iron (II sulfate adsorbed. The catalytic activity in the nitrogen monoxide reduction is higher in the exchanged zeolites than starting. Among all samples, those exchanged of iron (II has the higher catalytic activity. This lead to outline that, main catalytically active centers are associated with divalent iron.

  18. Carbon Monoxide Poisoning in a Child: A Case Report | Asani ...

    African Journals Online (AJOL)

    The exact incidence of carbon monoxide (CO) poisoning in Nigeria is unknown. Globally, CO poisoning is frequently unrecognized and under-reported since the clinical presentation is relatively non-specific. The circumstances usually involve an unsuspected increase of CO in an enclosed environment. We present the ...

  19. Carbon Monoxide Stable Isotopes: Extraction Technique Development and Urban Atmospheric Analysis

    Science.gov (United States)

    Vimont, Isaac Josef

    We have developed an extraction system to analyze isotopes of carbon monoxide (CO). We then analyzed CO isotopes for two years at Indianapolis, IN, USA. These measurements were done at three towers, one of which measured incoming, background air into the city. We quantitatively removed the background signal and determined the urban CO mole fraction and isotopic enhancements. During the winter months, we constrained the isotopic signature and concluded that the majority of CO produced during the winter was produced by fossil fuel combustion. We found that the Indianapolis fossil fuel signature differed from that of studies done in Europe. Further, we performed a limited traffic study to look at CO isotopes from traffic. While this was not conclusive, it did support our hypothesis that a larger fraction of the Indianapolis vehicle fleet may have malfunctioning catalytic systems, which biases the isotopic results, particularly for delta18O. We used the wintertime fossil fuel isotopic signature to help constrain the summertime budget. It was hypothesized that a second source of CO was significant during the summer months. Oxidation of biogenically produced volatile organic compounds (BVOC's) was one possible source. Oxidized BVOC's were consistent with the changes between our winter and summer isotopic source signatures. We then used the isotopic signatures to determine that between zero and sixty percent of the summertime CO budget was produced from oxidized VOC's. This provided the first direct evidence of a larger percentage of urban CO being produced by oxidized VOC's.

  20. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  1. Theoretical studies on the catalytic oxidation of carbon monoxide on nickel clusters

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, A.K.; Kojima, I.; Miyazaki, E.

    1986-01-01

    Complete neglect of differential overlap (CNDO) molecular orbital calculations using the method of Anno and Sakai for the evaluation of the valence orbital ionization potential (VOIP) were performed with the aim of studying the oxidation of carbon monoxide on nickel clusters. A cluster surface was assumed to be preadsorbed with oxygen and the variation of various bond energies with the approach of a carbon monoxide molecule was studied for different models. Various possibilities for the reaction path are discussed in the light of the theoretical findings and it is suggested that at a low coverage of oxygen the reaction may follow a Langmuir-Hinshelwood path, whereas at a high coverage, an Eley-Rideal path might be more probable. 55 references, 13 figures.

  2. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    International Nuclear Information System (INIS)

    Tong, Liping; Yu, K.N.; Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi; Han, Wei

    2014-01-01

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy

  3. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Liping [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Yu, K.N. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong (Hong Kong); Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Han, Wei, E-mail: hanw@hfcas.cn [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China)

    2014-01-15

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy.

  4. Pulverized coal devolatilization prediction

    International Nuclear Information System (INIS)

    Rojas, Andres F; Barraza, Juan M

    2008-01-01

    The aim of this study was to predict the two bituminous coals devolatilization at low rate of heating (50 Celsius degrade/min), with program FG-DVC (functional group Depolymerization. Vaporization and crosslinking), and to compare the devolatilization profiles predicted by program FG-DVC, which are obtained in the thermogravimetric analyzer. It was also study the volatile liberation at (10 4 k/s) in a drop-tube furnace. The tar, methane, carbon monoxide, and carbon dioxide, formation rate profiles, and the hydrogen, oxygen, nitrogen and sulphur, elemental distribution in the devolatilization products by FG-DVC program at low rate of heating was obtained; and the liberation volatile and R factor at high rate of heating was calculated. it was found that the program predicts the bituminous coals devolatilization at low rate heating, at high rate heating, a volatile liberation around 30% was obtained

  5. Acute Compartment Syndrome Which Causes Rhabdomyolysis by Carbon Monoxide Poisoning and Sciatic Nerve Injury Associated with It: A Case Report.

    Science.gov (United States)

    Ji, Jung-Woo

    2017-09-01

    Rhabdomyolysis is most frequently caused by soft tissue injury with trauma to the extremities. Non-traumatic rhabdomyolysis may be caused by alcohol or drug abuse, infection, collagen disease, or intensive exercise, but incidence is low. In particular, rhabdomyolysis resulting from carbon monoxide poisoning is especially rare. If caught before death, carbon monoxide poisoning has been shown to cause severe muscle necrosis and severe muscle damage leading to acute renal failure. In cases of carbon-monoxide-induced rhabdomyolsis leading to acute compartment syndrome in the buttocks and sciatic nerve injury are rare. We have experience treating patients with acute compartment syndrome due to rhabdomyolysis following carbon monoxide poisoning. We report the characteristic features of muscle necrosis observed during a decompression operation and magnetic resonance imaging findings with a one-year follow-up in addition to a review of the literature.

  6. Determination of percent calcium carbonate in calcium chromate

    International Nuclear Information System (INIS)

    Middleton, H.W.

    1979-01-01

    The precision, accuracy and reliability of the macro-combustion method is superior to the Knorr alkalimetric method, and it is faster. It also significantly reduces the calcium chromate waste accrual problem. The macro-combustion method has been adopted as the official method for determination of percent calcium carbonate in thermal battery grade anhydrous calcium chromate and percent calcium carbonate in quicklime used in the production of calcium chromate. The apparatus and procedure can be used to measure the percent carbonate in inorganic materials other than calcium chromate. With simple modifications in the basic apparatus and procedure, the percent carbon and hydrogen can be measured in many organic material, including polymers and polymeric formulations. 5 figures, 5 tables

  7. Measurements on high temperature fuel cells with carbon monoxide-containing fuel gases; Messungen an Hochtemperatur-Brennstoffzellen mit kohlenmonoxidhaltigen Brenngasen

    Energy Technology Data Exchange (ETDEWEB)

    Apfel, Holger

    2012-10-10

    In the present work the different power density of anode-supported high-temperature solid oxide fuel cells (ASC-SOFCs) were examined for carbon monoxide-containing fuels. In addition to wet hydrogen / carbon monoxide mixtures the cells were run with synthetic gas mixtures resembling the products of an autothermal reformer, and actual reformate generated by a 2 kW autothermal reformer. It was found that the power-voltage characteristics of an ASC depends primarily on the open circuit voltages of different gas mixtures, but is nearly independent of the hydrogen concentration of the fuel, although the reaction rates of other potential fuels within the gas mixture, namely carbon monoxide and methane, are much lower that the hydrogen reaction rate. The probable reason is that the main fuel for the electrochemical oxidation within the cell is hydrogen, while the nickel in the base layer of the anode acts as a reformer which replenishes the hydrogen by water reduction via carbon monoxide and methane oxidation.

  8. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    OpenAIRE

    Martijn eDiender; Alfons J.M. Stams; Alfons J.M. Stams; Diana Z. Sousa

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, ...

  9. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  10. 40 CFR Table 5 to Subpart Jjj of... - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units 5 Table 5 to Subpart JJJ of Part 62 Protection of... of Part 62—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units...

  11. Systemic Administration of Carbon Monoxide-Releasing Molecule-3 Protects the Skeletal Muscle in Porcine Model of Compartment Syndrome.

    Science.gov (United States)

    Bihari, Aurelia; Cepinskas, Gediminas; Sanders, David; Lawendy, Abdel-Rahman

    2018-05-01

    Acute limb compartment syndrome, a complication of musculoskeletal trauma, results in muscle necrosis and cell death. Carbon monoxide, liberated from the carbon monoxide-releasing molecule-3, has been shown protective in a rat model of compartment syndrome. The purpose of this study was to test the effect of carbon monoxide-releasing molecule-3 in a preclinical large animal model of compartment syndrome, with the ultimate goal of developing a pharmacologic adjunct treatment for compartment syndrome. Animal research study. Basic research laboratory in a hospital setting. Male Yorkshire-Landrace pigs (50-60 kg). Pigs underwent 6 hours of intracompartmental pressure elevation by infusing fluid into the anterior compartment of the right hind limb. Carbon monoxide-releasing molecule-3 was administered systemically (2 mg/kg, IV) at fasciotomy, followed by 3-hour reperfusion. Muscle perfusion, inflammation, injury, and apoptosis were assessed in the skeletal muscle. Systemic leukocyte activation was assessed during compartment syndrome and reperfusion. Elevation of hind limb intracompartmental pressure resulted in significant microvascular perfusion deficits (44% ± 1% continuously perfused capillaries in compartment syndrome vs 76% ± 4% in sham; p molecule-3 at fasciotomy increased the number of continuously perfused capillaries (68% ± 3%; p molecule-3 at fasciotomy offered protection against compartment syndrome-induced microvascular perfusion deficit, tissue injury, and systemic leukocyte activation. The data suggest the potential therapeutic application of carbon monoxide-releasing molecule-3 to patients at risk of developing compartment syndrome.

  12. Range measurements of keV hydrogen ions in solid oxygen and carbon monoxide

    International Nuclear Information System (INIS)

    Schou, J.; Soerensen, H.; Andersen, H.H.; Nielsen, M.; Rune, J.

    1984-01-01

    Ranges of 1.3-3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen. The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees with that previously found for solid nitrogen. (orig.)

  13. Silicon Monoxide at 1 atm and Elevated Pressures: Crystalline or Amorphous?

    KAUST Repository

    AlKaabi, Khalid

    2014-03-05

    The absence of a crystalline SiO phase under ordinary conditions is an anomaly in the sequence of group 14 monoxides. We explore theoretically ordered ground-state and amorphous structures for SiO at P = 1 atm, and crystalline phases also at pressures up to 200 GPa. Several competitive ground-state P = 1 atm structures are found, perforce with Si-Si bonds, and possessing Si-O-Si bridges similar to those in silica (SiO2) polymorphs. The most stable of these static structures is enthalpically just a little more stable than a calculated random bond model of amorphous SiO. In that model we find no segregation into regions of amorphous Si and amorphous SiO2. The P = 1 atm structures are all semiconducting. As the pressure is increased, intriguing new crystalline structures evolve, incorporating Si triangular nets or strips and stishovite-like regions. A heat of formation of crystalline SiO is computed; it is found to be the most negative of all the group 14 monoxides. Yet, given the stability of SiO2, the disproportionation 2SiO (s) → Si(s)+SiO2(s) is exothermic, falling right into the series of group 14 monoxides, and ranging from a highly negative ΔH of disproportionation for CO to highly positive for PbO. There is no major change in the heat of disproportionation with pressure, i.e., no range of stability of SiO with respect to SiO2. The high-pressure SiO phases are metallic. © 2014 American Chemical Society.

  14. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    Directory of Open Access Journals (Sweden)

    Metin Uysalol

    2011-09-01

    Full Text Available Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide intoxication was heaters, waterheaters and fi re in 82.1%, 7.1% and 6% of cases, respectively. There was a statistically signifi cant difference between the carboxyhemoglobin levels of the patients according to the clinical classifi cation (p<0.05. The intoxication caused by heaters was observed signifi cantly in November, December and January (p<0.001, between 16:00-24:00 hours (p<0.001 and among more than one member of a family (p<0.001. A medium level correlation was detected between the treatment approach and clinical classifi cation (r=0.50, p<0.001. Conclusion: Carbon monoxide intoxication, in the presented series, was found to develop accidentally; mostly in the Winter season; during night hours when the family members gathered together. The carboxyhemoglobin levels were appropriate with the developing clinical findings. Carboxyhemoglobin level solely was not enough for achieving the diagnosis and planning the treatment.

  15. 40 CFR Table 2 to Subpart Aaaa of... - Carbon Monoxide Emission Limits for New Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for New... Pt. 60, Subpt. AAAA, Table 2 Table 2 to Subpart AAAA of Part 60—Carbon Monoxide Emission Limits for.... Compliance is determined by continuous emission monitoring systems. b Block averages, arithmetic mean. See...

  16. Iron monoxide photodissociation

    Science.gov (United States)

    Chestakov, D. A.; Parker, D. H.; Baklanov, A. V.

    2005-02-01

    The photodissociation of Fe56O was studied by means of the velocity map imaging technique. A molecular beam of iron atoms and iron monoxide molecules was created using an electrical discharge with an iron electrode in a supersonic expansion of molecular oxygen. The ground state iron atom Fe(D45) and FeO concentrations in the molecular beam have been estimated. The dissociation energy of the FeO XΔ5 ground electronic state was found to be D00(FeO )=4.18±0.01eV. The effective absorption cross section of FeO at 252.39nm (vac), leading to the Fe(D45)+O(P3) dissociation channel, is ˜1.2×10-18cm2. A (1+1) resonantly enhanced multiphoton ionization spectrum of Fe56O in the region 39550-39580 cm-1 with rotational structure has been observed, but not assigned. Angular distributions of Fe(D45) and Fe(D35) products for the channel FeO →Fe(D4,35)+O(P3) have been measured at several points in the 210-260nm laser light wavelength region. The anisotropy parameter varies strongly with wavelength for both channels.

  17. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  18. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0....... Correlations between mean ADC and EI and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between EI and %predicted DLCO (r=0.76). CONCLUSION: HP (3)He-MRI correlates well with density measurements from MSCT and agrees better...

  19. The Range of 1-3 keV Electrons in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Oehlenschlæger, M.; Andersen, H.H.; Schou, Jørgen

    1985-01-01

    The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than that in n......The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than...

  20. Emphysema Distribution and Diffusion Capacity Predict Emphysema Progression in Human Immunodeficiency Virus Infection

    Science.gov (United States)

    Leung, Janice M; Malagoli, Andrea; Santoro, Antonella; Besutti, Giulia; Ligabue, Guido; Scaglioni, Riccardo; Dai, Darlene; Hague, Cameron; Leipsic, Jonathon; Sin, Don D.; Man, SF Paul; Guaraldi, Giovanni

    2016-01-01

    Background Chronic obstructive pulmonary disease (COPD) and emphysema are common amongst patients with human immunodeficiency virus (HIV). We sought to determine the clinical factors that are associated with emphysema progression in HIV. Methods 345 HIV-infected patients enrolled in an outpatient HIV metabolic clinic with ≥2 chest computed tomography scans made up the study cohort. Images were qualitatively scored for emphysema based on percentage involvement of the lung. Emphysema progression was defined as any increase in emphysema score over the study period. Univariate analyses of clinical, respiratory, and laboratory data, as well as multivariable logistic regression models, were performed to determine clinical features significantly associated with emphysema progression. Results 17.4% of the cohort were emphysema progressors. Emphysema progression was most strongly associated with having a low baseline diffusion capacity of carbon monoxide (DLCO) and having combination centrilobular and paraseptal emphysema distribution. In adjusted models, the odds ratio (OR) for emphysema progression for every 10% increase in DLCO percent predicted was 0.58 (95% confidence interval [CI] 0.41–0.81). The equivalent OR (95% CI) for centrilobular and paraseptal emphysema distribution was 10.60 (2.93–48.98). Together, these variables had an area under the curve (AUC) statistic of 0.85 for predicting emphysema progression. This was an improvement over the performance of spirometry (forced expiratory volume in 1 second to forced vital capacity ratio), which predicted emphysema progression with an AUC of only 0.65. Conclusion Combined paraseptal and centrilobular emphysema distribution and low DLCO could identify HIV patients who may experience emphysema progression. PMID:27902753

  1. Fetal brain damage following maternal carbon monoxide intoxication: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Ginsberg, M D; Myers, R E

    1974-01-01

    Techniques of fetal monitoring, including fetal blood sampling in utero, were employed to study the physiological effects of acute maternal carbon monoxide intoxication on nine term-pregnant female rhesus monkeys exposed to 0.1 to 0.3% inspired carbon monoxide over 1 to 3 hr. The mothers tolerated carboxyhemoglobin levels exceeding 60% without clinical sequelae, whereas the fetuses promptly developed profound hypoxia upon exposure of the mothers to CO. The fetal COHb levels rose only gradually over 1 to 3 hr, and thus contributed only slightly to the development of early fetal hypoxia. The fetal hypoxia was associated with bradycardia, hypotension, and metabolic and respiratory acidosis. Severity of intrauterine hypoxia was closely correlated with the appearance of brain damage. Brain swelling associated with hemorrhagic necrosis of the cerebral hemispheres (severe brain damage) appeared only in fetuses whose arterial oxygen content was reduced below 1.0 ml/100 ml for at least 45 min during the maternal CO intoxication.

  2. 26 CFR 301.6226(b)-1 - 5-percent group.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false 5-percent group. 301.6226(b)-1 Section 301.6226... ADMINISTRATION PROCEDURE AND ADMINISTRATION Assessment In General § 301.6226(b)-1 5-percent group. (a) In general. All members of a 5-percent group shall join in filing any petition for judicial review. The...

  3. Conversion of no-carrier-added [11C]carbon dioxide to [11C]carbon monoxide on molybdenum for the synthesis of 11C-labelled aromatic ketones

    International Nuclear Information System (INIS)

    Zeisler, S.K.; Nader, M.; Theobald, A.; Oberdorfer, F.

    1997-01-01

    A new method for the efficient conversion of no-carrier-added [ 11 C]carbon dioxide into [ 11 C]carbon monoxide is described. [ 11 C]Carbon dioxide produced by proton bombardment of ultra high purity nitrogen is pre-concentrated in a cryo trap and then passed through a quartz tube filled with a mesh of thin molybdenum wire heated to 850 o C. [ 11 C]Carbon dioxide readily reacts with molybdenum to form [ 11 C]carbon monoxide and molybdenum(IV) oxide. The latter also reduces carbon dioxide to carbon monoxide and helps improve the performance of the converter. [ 11 C]Carbon monoxide is purified from remaining [ 11 C]carbon dioxide and collected in a small silica trap from which it is eluted into a reaction mixture for the palladium-mediated synthesis of a 11 C-labelled aromatic ketone. Radiochemical yields of up to 81% (decay-corrected) for [ 11 C]carbon monoxide were obtained. Radiochemical purity and specific radioactivity of both [ 11 C]carbon monoxide and the 11 C-labelled ketone are sufficient for nuclear medical studies with PET. (Author)

  4. Iodine monoxide in the north subtropical free troposphere

    OpenAIRE

    O. Puentedura; M. Gil; A. Saiz-Lopez; T. Hay; M. Navarro-Comas; A. Gómez-Pelaez; E. Cuevas; J. Iglesias; L. Gomez

    2012-01-01

    Iodine monoxide (IO) differential slant column densities (DSCD) have been retrieved from a new multi-axis differential optical absorption spectroscopy (MAX-DOAS) instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and hence is representative of the free troposphere. We r...

  5. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  6. Characterization of the uranium--2 weight percent molybdenum alloy

    International Nuclear Information System (INIS)

    Hemperly, V.C.

    1976-01-01

    The uranium-2 wt percent molybdenum alloy was prepared, processed, and age hardened to meet a minimum 930-MPa yield strength (0.2 percent) with a minimum of 10 percent elongation. These mechanical properties were obtained with a carbon level up to 300 ppM in the alloy. The tensile-test ductility is lowered by the humidity of the laboratory atmosphere

  7. Carbon monoxide poisoning in Nigeria - it is time to pay attention ...

    African Journals Online (AJOL)

    Background: Carbon monoxide (CO) is a colourless, odourless gas and a cause of thousands of deaths across the world annually but its lethal consequences often go unrecognized, especially in developing countries. Aim: To discuss the subject of CO poisoning using local examples. Methods: Information was drawn from ...

  8. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    Science.gov (United States)

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  9. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  10. [Cerebellar Infarction After Carbon Monoxide Poisoning and Hyperbaric Oxygen Therapy].

    Science.gov (United States)

    Wick, Matthias; Schneiker, André; Bele, Sylvia; Pawlik, Michael; Meyringer, Helmut; Graf, Bernhard; Wendl, Christina; Kieninger, Martin

    2017-06-01

    We report on a patient who developed a space-occupying cerebellar infarction with occlusive hydrocephalus after a poisoning with carbon monoxide with the intention to commit suicide. A neurosurgical and intensive care therapy were needed. The patient's survival without severe neurological deficits could be secured due to the early detection of the intracerebral lesions. Georg Thieme Verlag KG Stuttgart · New York.

  11. The relationships between percent body fat and other ...

    African Journals Online (AJOL)

    The relationships between percent body fat and other anthropometric nutritional predictors among male and female children in Nigeria. ... A weak significant positive correlation was observed between the percent body fat and height – armspan ratio ... There was evidence of overweight and obesity in both children. The mid ...

  12. 40 CFR Table 5 to Subpart Bbbb of... - Model Rule-Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Carbon Monoxide Emission... BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste... PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...

  13. Carbon monoxide is not responsible for the cigarette smokeinduced changes in the pulmonary metabolism of arachidonic acid and prostaglandin E2

    International Nuclear Information System (INIS)

    Maennistoe, J.; Puustinen, T.; Uotila, P.

    1985-01-01

    Cigarette smoke is known to interfere with the pulmonary metabolism of arachidomic acid and prostaglandin E 2 (PGE 2 ). We investigated the possible role of carbon monoxide in these cigarette smoke-infuced alterations. 4 C-Arachidonic acid (50 nmol) was indused into the pulmonary circulation of isolated perfused hamster lungs and the radioactive metabolites in the perfusion effluent, as well as the distribution of incorporated radioactive arachidonic acid within the lung lipids, were analysed. Carbon monoxide, added into the ventilatory air, had no effect on the oxidative metabolism of arachidonic acid or on the distribution of radioactive arachidonic acid within the lung. In addition, carbon monoxide had no effect on the metabolism of PGE 2 following infusion of 100 nmol of 14 C-PGE 2 into the rat pulmonary circulation. The present study suggests that carbon monoxide is not responsible for the cigarette smoke-induced changes in the pulmonary metabolism of arachidonic acid and PGE 2 . (author)

  14. Titanium monoxide spectroscopy following laser-induced optical breakdown

    International Nuclear Information System (INIS)

    Parigger, Christian G.; Woods, Alexander C.; Keszler, Anna; Nemes, László; Hornkohl, James O.

    2012-01-01

    This work investigates Titanium Monoxide (TiO) in ablation-plasma by employing laser-induced breakdown spectroscopy (LIBS) with 1 to 10 TW/cm 2 irradiance, pulsed, 13 nanosecond, Q-switched Nd:YAG laser radiation at the fundamental wavelength of 1064 nm. The analysis of TiO is based on our first accurate determination of transition line strengths for selected TiO A-X, B-X, and E-X transitions, particularly TiO A-X γ and B-X γ′ bands. Electric dipole line strengths for the A 3 Φ-X 3 δ and B 3 Π-X 3 δ bands of TiO are computed. The molecular TiO spectra are observed subsequent to laser-induced breakdown (LIB). We discuss analysis of diatomic molecular spectra that may occur simultaneously with spectra originating from atomic species. Gated detection is applied to investigate the development in time of the emission spectra following LIB. Collected emission spectra allow one to infer micro-plasma parameters such as temperature and electron density. Insight into the state of the micro-plasma is gained by comparing measurements with predictions of atomic and molecular spectra. Nonlinear fitting of recorded and computed diatomic spectra provides the basis for molecular diagnostics, while atomic species may overlap and are simultaneously identified. Molecular diagnostic approaches similar to TiO have been performed for diatomic molecules such as AlO, C 2 , CN, CH, N 2 , NH, NO and OH.

  15. The Future of Carbon Monoxide Measurements from Space

    Science.gov (United States)

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  16. Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.

    Science.gov (United States)

    Towers, Craig V; Corcoran, Vincent A

    2009-03-01

    The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.

  17. Effects of acetylene and carbon monoxide on long-term hydrogen production by Mastigocladus laminosus, a thermophilic blue-green alga

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Yokoyama, H; Takahara, K; Miyamoto, K

    1982-01-01

    Long-term H/sub 2/ production by a thermophilic and heterocystous blue-green alga (cyanobacterium) Mastigocladus laminosus was studied under the conditions when acetylene and carbon monoxide were supplemented to the gas phase of the culture vessel. The addition of both gases enhanced H/sub 2/ evolution by nitrogen-starved cells. The concentrations of acetylene and carbon monoxide in the gas phase of argon/CO/sub 2/ (97.5/2.5) were 10% and 0.2 to 1%, respectively, for the maximum H/sub 2/ production. Renewals of the gas phase, in addition to the addition of acetylene and carbon monoxide, were necessary for durable H/sub 2/ production. Since the concentrations of both H/sub 2/ and O/sub 2/ accumulated in the gas phase were minimized after the renewals, the H/sub 2/ uptake activity, which was not completely inhibited by acetylene and carbon monoxide, was reduced and thereby H/sub 2/ evolution was restored. Under such conditions, H/sub 2/ production for up to 20 days was observed under argon and N/sub 2/ atmospheres with average rats of 3.9 and 3.3..mu..l/mg dry wt/h, respectively. H/sub 2/ evolution for 15 days was observed even under an air atmosphere containing acetylene and carbon monoxide. It was thus shown that prolonged production of H/sub 2/ was possible by the use of a blue-green alga which exhibits a high activity of H/sub 2/ uptake under nitrogen-starved conditions.

  18. MODELLING OF CARBON MONOXIDE AIR POLLUTION IN LARG CITIES BY EVALUETION OF SPECTRAL LANDSAT8 IMAGES

    Directory of Open Access Journals (Sweden)

    M. Hamzelo

    2015-12-01

    Full Text Available Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS , spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  19. Carbon monoxide concentration in donated blood: relation to cigarette smoking and other sources.

    Science.gov (United States)

    Aberg, Anna-Maja; Sojka, Birgitta Nilsson; Winsö, Ola; Abrahamsson, Pernilla; Johansson, Göran; Larsson, Jan Erik

    2009-02-01

    Carbon monoxide (CO) is normally present in the human body due to endogenous production of CO. CO can also be inhaled by exposure to external sources such as cigarette smoke, car exhaust, and fire. The purpose of this study was to investigate CO concentrations in blood from 410 blood donors at the blood center in Umeå, Sweden. To further evaluate the effects of cigarette smoking on CO concentrations, the elimination time for CO was examined in six volunteer smokers after a smoked cigarette. Blood samples from whole blood donors were obtained during the blood center's routine operation. In connection with blood donations, demographic and behavioral data were collected from the donors. The CO concentration was determined using gas chromatography. The majority of blood donors had approximately the same CO concentration (mean, 84.5 micromol/L). In 6 percent of the samples, the concentrations were higher than 130 micromol per L. The highest CO concentration was 561 micromol per L. The main source for these high CO concentrations appeared to be cigarette smoking. In the volunteer smokers, the elimination time after a smoked cigarette varied significantly, with elimination half-lives from 4.7 to 8.4 hours. These results show that blood bank red blood cell bags may have CO concentrations above the physiologic level. The time interval between cigarette smoking and blood donation seems to be a particularly important factor for elevated CO concentrations.

  20. Polarity and Nonpolarity of Ionic Liquids Viewed from the Rotational Dynamics of Carbon Monoxide.

    Science.gov (United States)

    Yasaka, Y; Kimura, Y

    2015-12-17

    The rotational dynamics of carbon monoxide (CO) in a molten salt, ionic liquids (ILs), and alkanes were investigated by (17)O NMR T1 measurements using labeled C(17)O. The molten salt and the studied ILs have the bis(trifluoromethanesulfonyl)imide anion ([NTf2](-)) in common. In hexane near room temperature, the rotational relaxation times are close to the values predicted from the slip boundary condition in the Stokes-Einstein-Debye (SED) theory. However, in contradiction to the theoretical prediction, the rotational relaxation times decrease as the value of η/T increases, where η and T are the viscosity and absolute temperature, respectively. In other alkanes and ILs used in this study, the rotational relaxation times are much faster than those predicted by SED, and show a unique dependence on the number of alkyl carbons. For the same value of η/T, the CO rotational relaxation times in ILs composed of short-alkyl-chain-length imidazolium cations (1-ethyl-3-methylimidazolium and 1-butyl-3-methylimidazolium) are close to those for a molten salt (Cs[NTf2]). On the other hand, the rotational relaxation times in ILs composed of long-chain-length imidazolium (1-methyl-3-octylimidazolium) and phosphonium (tributylmethylphosphonium and tetraoctylphosphonium) cations are much shorter than the SED predictions. This deviation from theory increases as the alkyl chain length increases. We also found that the rotational relaxation times in dodecane and squalane are similar to those in ILs with a similar number of alkyl carbons. These results are discussed in terms of heterogeneous solvation and in comparison with the translational diffusion of CO in ILs.

  1. 7 CFR 762.129 - Percent of guarantee and maximum loss.

    Science.gov (United States)

    2010-01-01

    ... loss. (a) General. The percent of guarantee will not exceed 90 percent based on the credit risk to the lender and the Agency both before and after the transaction. The Agency will determine the percentage of... PLP lenders will not be less than 80 percent. (d) Maximum loss. The maximum amount the Agency will pay...

  2. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad; Farooq, Aamir

    2018-01-01

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm

  3. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    Science.gov (United States)

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  4. Catalytic hydrogenation of carbon monoxide

    International Nuclear Information System (INIS)

    Wayland, B.B.

    1993-12-01

    Focus of this project is on developing new approaches for hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. The strategies to accomplish CO reduction are based on favorable thermodynamics manifested by rhodium macrocycles for producing a series of intermediates implicated in the catalytic hydrogenation of CO. Metalloformyl complexes from reactions of H 2 and CO, and CO reductive coupling to form metallo α-diketone species provide alternate routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics are promising candidates for future development

  5. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    Science.gov (United States)

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  6. Health effects of carbon monoxide environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    Carbon monoxide's (CO) chronic effects on man, its sources, and measuring methods are reviewed, and guidelines to determine health criteria are considered. The European data exchange included CO measuring methods in air and blood and their use in survey and experimental work, atmospheric CO pollution and sampling methods in urban thoroughfares and road tunnels in the European countries, a population survey of carboxyhemoglobin levels from cigarette smoking and atmospheric exposure, and physiological kinetics (uptake, distribution, and elimination) of CO inhalation. Additional topics are CO and the central nervous system, effects of moderate CO exposure on the cardiovascular system and on fetal development, and the current views on existing air quality criteria for CO.

  7. Detection of viability by percent thallium uptake with conventional thallium scintigraphy

    International Nuclear Information System (INIS)

    Imai, Kamon; Araki, Yasushi; Horiuchi, Kou-ichi; Yumikura, Sei; Saito, Satoshi; Ozawa, Yukio; Kan-matsuse, Katsuo; Hagiwara, Kazuo.

    1994-01-01

    Thallium myocardial scintigraphy (TMS) is used for diagnosis of viability in infarcted myocardium before coronary revascularization. Underestimation of viability by TMS has been reported by many investigators. To evaluate viability precisely, thallium re-injection method or 24 hour delayed imaging is performed. However, these techniques are not convenient and are difficult to perform in clinical practice. Percent T1-uptake method was developed for predicting myocardial viability. To evaluate usefulness of this method, TMS was performed before and after PTCA in 23 patients with myocardial infarction. Left ventricle was divided into 3 layers, then each layer was divided into 4 segments (12 segments in total). Forth three segments showed recovery of perfusion on TMS after PTCA. Viability in infarcted myocardium is predicted by 1) redistribution (RD), 2) %T1-uptake≥45% on the image immediately after exercise (TE), and 3) %T1-uptake≥45% on delayed image (TD). Sensitivity was RD: 60%, TE: 90% and TD: 95% (p<0.001 vs. RD). Specificity was RD: 74%, TE: 68%, and TD: 60% (NS). Predictive accuracy (PA) was RD: 69%, TE: 77%, TD: 73% (NS). Compared with RD, %T1-uptake, either TE or TD, increased sensitivity with slightly improved PA, but decreased specificity slightly. Therefore %T1-uptake would be a sensitive and useful predictor to find patients who are most likely to benefit from re-vascularization. (author)

  8. Calculated Specific Volumes and Magnetic Moments of the 3d Transition Metal Monoxides

    DEFF Research Database (Denmark)

    Skriver, Hans Lomholt; Andersen, O. K.; Johansson, B.

    1980-01-01

    We have performed self-consistent, spin-polarized band structure calculations as a function of the lattice spacing for the 3d metal monoxides in order to obtain the equilibrium lattice constants. The calculated binding from the 3d electrons and the occurrence of antiferromagnetism account...

  9. Multimodel simulations of carbon monoxide: comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Krol, M.C.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-ofthe- art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  10. The effectiveness of breath carbon monoxide analyzer in screening for environmental tobacco smoke exposure in Saudi pregnant women

    Directory of Open Access Journals (Sweden)

    Rasmieh Ayed Alzeidan

    2013-01-01

    Full Text Available Background: Exposure to environmental tobacco smoke (ETS has harmful effects on the pregnancy outcomes similar to those observed in actively smoking pregnant women. The aim of this study was to estimate the sensitivity and specificity of the breath carbon monoxide (BCO analysis in the assessment of smoking status among Saudi pregnant women, including ETS exposure compared to self-reported tobacco smoke exposure. Methods: A cross-sectional design was used during January 2012, 560 pregnant women, irrespective of their gestational age, agreed to undergo BCO testing and completed the data collection sheet for the study. Sensitivity, specificity, positive and negative predictive values were calculated to compare the BCO test with self-reported exposure to ETS. Results: Of the study population 151 (27% women self-reported ETS exposure during the index pregnancy, 409 (73% self-reported non-exposure. Sensitivity of the test was 32.5% (95% CI; 25.2-40.3%, the Specificity was much higher at 69.2% (95% CI; 64.4-73.5%, the positive predictive value was 28% (95% CI, 21.9-35.1%, and the negative predictive value was 73.5% (95% CI; 68.9-77.7%. Conclusion: The BCO test is an ineffective tool to detect the level of ETS exposure among Saudi pregnant women.

  11. Prediction-based dynamic load-sharing heuristics

    Science.gov (United States)

    Goswami, Kumar K.; Devarakonda, Murthy; Iyer, Ravishankar K.

    1993-01-01

    The authors present dynamic load-sharing heuristics that use predicted resource requirements of processes to manage workloads in a distributed system. A previously developed statistical pattern-recognition method is employed for resource prediction. While nonprediction-based heuristics depend on a rapidly changing system status, the new heuristics depend on slowly changing program resource usage patterns. Furthermore, prediction-based heuristics can be more effective since they use future requirements rather than just the current system state. Four prediction-based heuristics, two centralized and two distributed, are presented. Using trace driven simulations, they are compared against random scheduling and two effective nonprediction based heuristics. Results show that the prediction-based centralized heuristics achieve up to 30 percent better response times than the nonprediction centralized heuristic, and that the prediction-based distributed heuristics achieve up to 50 percent improvements relative to their nonprediction counterpart.

  12. Analysis of patients presenting to the emergency department with carbon monoxide intoxication

    Directory of Open Access Journals (Sweden)

    Selim Yurtseven

    2015-12-01

    Full Text Available Objectives: Carbon monoxide is a potentially fatal form of poisoning. The exact incidence is unclear, due to cases being undiagnosed or reported as fewer than the real number. Hyperbaric oxygen therapy (HBOT is of proven efficacy in the treatment of CO intoxication.The purpose of this study was to describe the general characteristics of carbon monoxide (CO intoxications presenting to the emergency department and to investigate troponin I values and the effectiveness of hyperbaric oxygen therapy (HBOT in these patients. Material and methods: Patients presenting to the emergency department with CO intoxication over one year and patients with such intoxications receiving HBOT were examined retrospectively. Results: One hundred seventy-one patients were included; 140 (81.9% were poisoned by stoves, 18 (10.5% by hot water boilers and 10 in (5.8% by fires. COHb levels were normal in 49 of the 163 patients whose values were investigated, and were elevated in 114 patients. Mean COHb value was 16.6. Troponin I values were investigated in 112 patients. These were normal in 86 patients and elevated in 26. Mean troponin I value was 0.38 ng/ml. One hundred twenty-three of the 171 patients in the study were discharged in a healthy condition after receiving normobaric oxygen therapy, while 48 patients received HBOT. Forty-two (87.5% of the patients receiving HBOT were discharged in a healthy condition while sequelae persisted in five (10.4%. One patient died after 15 session of HBOT. Conclusion: Although elevated carboxyhemoglobin confirms diagnosis of CO intoxication, normal levels do not exclude it. Troponin I levels may rise in CO intoxication. No significant relation was observed between carboxyhemoglobin and receipt of HBOT. A significant correlation was seen, however, between troponin I levels and receipt of HBOT. Keywords: Carbon monoxide intoxication, Hyperbaric oxygen, Troponin I, Echocardiography

  13. Respiratory diseases in preschool children in the city of Niš exposed to suspended particulates and carbon monoxide from ambient air

    Directory of Open Access Journals (Sweden)

    Đorđević Amelija

    2016-01-01

    Full Text Available Background/Aim. Analysis of air quality in Serbia indicates that the city of Niš belongs to a group of cities characterized by the third category of air quality (excessive air pollution. The aim of the study was to analyze the degree of causality between ambient air quality affected by particulate matter of 10 μm (PM10 and carbon monoxide (CO and the incidence of respiratory diseases in preschool children in the city of Niš. Methods. We quantified the influence of higher PM10 concentrations and carbon monoxide comprising motor vehicle exhausts in the city of Niš on the occurrence of unwanted health effects in preschool children by means of the hazard quotient (HQ, individual health risk (Ri, and the probability of cancer (ICR. The methodology used was according to the US Environmental Protection Agency (EPA, and it included basic scientific statistical methods, compilation methods, and the relevant mathematical methods for assessing air pollution health risk, based on the use of attribute equations. Results. Measurement of ambient air pollutant concentrations in the analyzed territory for the entire monitoring duration revealed that PM10 concentrations were significantly above the allowed limits during 80% of the days. The maximum measured PM10 concentration was 191.6 μg/m3, and carbon monoxide 5.415 mg/m3. The incidence of respiratory diseases in the experimental group, with a prominent impact of polluted air was 57.17%, whereas the incidence in the control group was considerably lower, 41.10 %. There were also significant differences in the distribution of certain respiratory diseases. Conclusion. In order to perform good causal analysis of air quality and health risk, it is very important to establish and develop a system for long-term monitoring, control, assessment, and prediction of air pollution. We identified the suspended PM10 and CO as ambient air pollutants causing negative health effects in the exposed preschool children

  14. Multimodel simulations of carbon monoxide: Comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Faluvegi, G.; Stevenson, D.S.; Krol, M.C.; Emmons, L.K.; Lamarque, J.F.; Petron, G.; Dentener, F.J.; Ellingsen, K.; Schultz, M.G.; Wild, O.; Amann, M.; Atherton, C.S.; Bergmann, D.J.; Bey, I.; Butler, T.; Cofala, J.; Collins, W.J.; Derwent, R.G.; Doherty, R.M.; Drevet, J.; Eskes, H.J.; Fiore, A.M.; Gauss, M.; Hauglustaine, D.A.; Horowitz, L.W.; Isaksen, I.S.A.; Lawrence, M.G.; Montanaro, V.; Muller, J.F.; Pitari, G.; Prather, M.J.; Pyle, J.A.; Rast, S.; Rodriguez, J.M.; Sanderson, M.G.; Savage, N.H.; Strahan, S.E.; Sudo, K.; Szopa, S.; Unger, N.; Noije, van T.P.C.; Zeng, G.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-of-the-art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  15. Does Asset Allocation Policy Explain 40, 90, 100 Percent of Performance?

    OpenAIRE

    Roger G. Ibbotson; Paul D. Kaplan

    2001-01-01

    Does asset allocation policy explain 40 percent, 90 percent, or 100 percent of performance? According to some well-known studies, more than 90 percent of the variability of a typical plan sponsor's performance over time is attributable to asset allocation. However, few people want to explain variability over time. Instead, an analyst might want to know how important it is in explaining the differences in return from one fund to another, or what percentage of the level of a typical fund's retu...

  16. Health aspects of automotive pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Jouan, M

    1973-01-01

    General health aspects of carbon monoxide, lead, nitrogen oxides, unburned hydrocarbons, and aldehydes are described. Unlike spark ignition engines, diesel engines emit but minimal quantities of carbon monoxide. Automotive carbon monoxide may cause chronic poisoning by its combination with hemoglobin. The threshold value beyond which physiological changes occur lies at 2.5 percent carboxyhemoglobin. Nitric oxide, and especially nitrogen dioxide cause pulmonary edema, impaired respiratory function, and chronic bronchitis in very low concentrations. According to regulations implemented in France, a CO concentration of 40 ppM/hr must occur not more than 1 percent of the time on a yearly basis. A level of 15 ppm must not be exceeded for more than 15 percent of the time in any 9-hour period. The maximum allowable 1-hour nitrogen oxide concentration is set at 0.25 ppM. The emission standards implemented, as well as favorable meteorological conditions have resulted in an abatement of the CO concentrations in Paris.

  17. Carbon monoxide exposures inside an automobile traveling on an urban arterial highway.

    Science.gov (United States)

    Ott, W; Switzer, P; Willits, N

    1994-08-01

    Carbon monoxide (CO) exposures were measured inside a motor vehicle during 88 standardized drives on a major urban arterial highway, El Camino Real (traffic volume of 30,500-45,000 vehicles per day), over a 13-1/2 month period. On each trip (lasting between 31 and 61 minutes), the test vehicle drove the same 5.9-mile segment of roadway in both directions, for a total of 11.8 miles, passing through 20 intersections with traffic lights (10 in each direction) in three California cities (Menlo Park, Palo Alto, and Los Altos). Earlier tests showed that the test vehicle was free of CO intrusion. For the 88 trips, the mean CO concentration was 9.8 ppm, with a standard deviation of 5.8 ppm. Of nine covariates that were examined to explain the variability in the mean CO exposures observed on the 88 trips (ambient CO at two fixed stations, atmospheric stability, seasonal trend function, time of day, average surrounding vehicle count, trip duration, proportion of time stopped at lights, and instrument type), a fairly strong seasonal trend was found. A model consisting of only a single measure of traffic volume and a seasonal trend component had substantial predictive power (R2 = 0.68); by contrast, the ambient CO levels, although partially correlated with average exposures, contributed comparatively little predictive power to the model. The CO exposures experienced while drivers waited at the red lights at an intersection ranged from 6.8 to 14.9 ppm and differed considerably from intersection to intersection.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Impacts of Process and Prediction Uncertainties on Projected Hanford Waste Glass Amount

    Energy Technology Data Exchange (ETDEWEB)

    Gervasio, Vivianaluxa [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Vienna, John D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kim, Dong-Sang [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kruger, Albert A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2018-02-19

    Analyses were performed to evaluate the impacts of using the advanced glass models, constraints (Vienna et al. 2016), and uncertainty descriptions on projected Hanford glass mass. The maximum allowable WOL was estimated for waste compositions while simultaneously satisfying all applicable glass property and composition constraints with sufficient confidence. Different components of prediction and composition/process uncertainties were systematically included in the calculations to evaluate their impacts on glass mass. The analyses estimated the production of 23,360 MT of IHLW glass when no uncertainties were taken into accound. Accounting for prediction and composition/process uncertainties resulted in 5.01 relative percent increase in estimated glass mass 24,531 MT. Roughly equal impacts were found for prediction uncertainties (2.58 RPD) and composition/process uncertainties (2.43 RPD). ILAW mass was predicted to be 282,350 MT without uncertainty and with weaste loading “line” rules in place. Accounting for prediction and composition/process uncertainties resulted in only 0.08 relative percent increase in estimated glass mass of 282,562 MTG. Without application of line rules the glass mass decreases by 10.6 relative percent (252,490 MT) for the case with no uncertainties. Addition of prediction uncertainties increases glass mass by 1.32 relative percent and the addition of composition/process uncertainties increase glass mass by an additional 7.73 relative percent (9.06 relative percent increase combined). The glass mass estimate without line rules (275,359 MT) was 2.55 relative percent lower than that with the line rules (282,562 MT), after accounting for all applicable uncertainties.

  19. Toxicological Investigation of Acute Carbon Monoxide Poisoning in Four Occupants of a Fuming Sport Utility Vehicle

    Directory of Open Access Journals (Sweden)

    Martin Nnoli

    2014-11-01

    Full Text Available Background: This toxicological investigation involves a report on the death of four occupants of a sport utility vehicle on one of the major busy Federal roads of Nigeria where they were held for up to three hours in a traffic jam while the car was steaming. Methods: Autopsy was executed using the standard procedure and toxicological analysis was done using simple spectrophotometric method to establish the level of carboxyhaemoglobin (HbCO in peripheral blood in the four occupants. Results: The autopsy report indicated generalized cyanosis, sub-conjuctival hemorrhages, marked laryngo-trachea edema with severe hyperemia with frothy fluid discharges characteristic of carbon monoxide poisoning. Toxicological report of the level of HbCO in part per million (ppm in the peripheral blood of the four occupants was A= 650 ppm; B= 500 ppm; C= 480 ppm, and D= 495 ppm against the maximum permissible level of 50 ppm. Conclusion: The sudden death of the four occupants was due to excessive inhalation of the carbon monoxide gas from the exhaust fumes leaking into the cabin of the car. The poor road network, numerous potholes, and traffic jam in most of roads in Nigeria could have exacerbated a leaky exhaust of the smoky second hand SUV car leading to the acute carbon monoxide poisoning.

  20. Carbon monoxide and respiratory symptoms in young adult passive smokers: A pilot study comparing waterpipe to cigarette

    Directory of Open Access Journals (Sweden)

    Rouba Zeidan

    2014-08-01

    Full Text Available Objectives: Studies have correlated second hand smoke (SHS with many diseases, especially respiratory effects. The goal of this study was to measure the impact of SHS on the respiratory symptoms and exhaled carbon monoxide. Material and Methods: The study population consisted of 50 young workers in restaurants serving waterpipes, 48 university students who sit frequently in the university cafeteria where cigarette smoking is allowed and 49 university students spending time in places where smoking is not allowed. Subjects completed questionnaires on socio-demographic characteristics, respiratory symptoms and exposure to SHS. Exhaled carbon monoxide levels were measured. ANOVA and Chi-square tests were used when applicable as well as linear and logistic regression analysis. Results: Exposure to cigarette smoke in university (adjusted odds ratio (ORa = 6.06 and occupational exposure to waterpipe smoke (ORa = 7.08 were predictors of chronic cough. Being married (ORa = 6.40, living near a heavy traffic road (ORa = 9.49 or near a local power generator (ORa = 7.54 appeared responsible for chronic sputum production. Moreover, predictors of chronic allergies were: being male (ORa = 7.81, living near a local power generator (ORa = 5.52 and having a family history of chronic respiratory diseases (ORa = 17.01. Carbon monoxide levels were augmented by the number of weekly hours of occupational exposure to waterpipe smoke (β = 1.46 and the number of daily hours of exposure to cigarette smoke (β = 1.14. Conclusions: In summary, young non-smoker subjects demonstrated more chronic cough and elevated carbon monoxide levels when exposed to SHS while the effect of waterpipe was even more evident.

  1. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Directory of Open Access Journals (Sweden)

    Martijn eDiender

    2015-11-01

    Full Text Available Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  2. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    Science.gov (United States)

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  3. New Class of Hybrid Materials for Detection, Capture, and "On-Demand" Release of Carbon Monoxide.

    Science.gov (United States)

    Pitto-Barry, Anaïs; Lupan, Alexandru; Ellingford, Christopher; Attia, Amr A A; Barry, Nicolas P E

    2018-04-25

    Carbon monoxide (CO) is both a substance hazardous to health and a side product of a number of industrial processes, such as methanol steam reforming and large-scale oxidation reactions. The separation of CO from nitrogen (N 2 ) in industrial processes is considered to be difficult because of the similarities of their electronic structures, sizes, and physicochemical properties (e.g., boiling points). Carbon monoxide is also a major poison in fuel cells because of its adsorption onto the active sites of the catalysts. It is therefore of the utmost economic importance to discover new materials that enable effective CO capture and release under mild conditions. However, methods to specifically absorb and easily release CO in the presence of contaminants, such as water, nitrogen, carbon dioxide, and oxygen, at ambient temperature are not available. Here, we report the simple and versatile fabrication of a new class of hybrid materials that allows capture and release of carbon monoxide under mild conditions. We found that carborane-containing metal complexes encapsulated in networks made of poly(dimethylsiloxane) react with CO, even when immersed in water, leading to dramatic color and infrared signature changes. Furthermore, we found that the CO can be easily released from the materials by simply dipping the networks into an organic solvent for less than 1 min, at ambient temperature and pressure, which not only offers a straightforward recycling method, but also a new method for the "on-demand" release of carbon monoxide. We illustrated the utilization of the on-demand release of CO from the networks by carrying out a carbonylation reaction on an electron-deficient metal complex that led to the formation of the CO-adduct, with concomitant recycling of the gel. We anticipate that our sponge-like materials and scalable methodology will open up new avenues for the storage, transport, and controlled release of CO, the silent killer and a major industrial poison.

  4. The Texas Ten Percent Plan's Impact on College Enrollment

    Science.gov (United States)

    Daugherty, Lindsay; Martorell, Paco; McFarlin, Isaac, Jr.

    2014-01-01

    The Texas Ten Percent Plan (TTP) provides students in the top 10 percent of their high-school class with automatic admission to any public university in the state, including the two flagship schools, the University of Texas at Austin and Texas A&M. Texas created the policy in 1997 after a federal appellate court ruled that the state's previous…

  5. High Resolution Spectra of Carbon Monoxide, Propane and Ammonia for Atmospheric Remote Sensing

    Science.gov (United States)

    Beale, Christopher Andrew

    Spectroscopy is a critical tool for analyzing atmospheric data. Identification of atmospheric parameters such as temperature, pressure and the existence and concentrations of constituent gases via remote sensing techniques are only possible with spectroscopic data. These form the basis of model atmospheres which may be compared to observations to determine such parameters. To this end, this dissertation explores the spectroscopy of three molecules: ammonia, propane and carbon monoxide. Infrared spectra have been recorded for ammonia in the region 2400-9000 cm-1. These spectra were recorded at elevated temperatures (from 293-973 K) using a Fourier Transform Spectrometer (FTS). Comparison between the spectra recorded at different temperatures yielded experimental lower state energies. These spectra resulted in the measurement of roughly 30000 lines and about 3000 quantum assignments. In addition spectra of propane were recorded at elevated temperatures (296-700 K) using an FTS. Atmospheres with high temperatures require molecular data at appropriate conditions. This dissertation describes collection of such data and the potential application to atmospheres in our solar system, such as auroral regions in Jupiter, to those of planets orbiting around other stars and cool sub-stellar objects known as brown dwarfs. The spectra of propane and ammonia provide the highest resolution and most complete experimental study of these gases in their respective spectral regions at elevated temperatures. Detection of ammonia in an exoplanet or detection of propane in the atmosphere of Jupiter will most likely rely on the work presented here. The best laboratory that we have to study atmospheres is our own planet. The same techniques that are applied to these alien atmospheres originated on Earth. As such it is appropriate to discuss remote sensing of our own atmosphere. This idea is explored through analysis of spectroscopic data recorded by an FTS on the Atmospheric Chemistry

  6. Forensic aspects of carbon monoxide poisoning by charcoal burning in Denmark, 2008-2012

    DEFF Research Database (Denmark)

    Nielsen, Pia Rude; Gheorghe, Alexandra; Lynnerup, Niels

    2014-01-01

    Carbon monoxide (CO) inhalation is a well-known method of committing suicide. There has been a drastic increase in suicide by inhalation of CO, produced from burning charcoal, in some parts of Asia, and a few studies have reported an increased number of these deaths in Europe. CO-related deaths c...

  7. A Rare Cause of Chronic Headache that May Be Misdiagnosed as Migraine: Chronic Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet Kenan KANBUROGLU

    2014-09-01

    Full Text Available SUMMARY: Differential diagnosis of primary headache disorders can be challenging for physicians. Although the association of headache with acute carbon monoxide intoxication is very well-defined, in refractory nonspecific headaches associated with chronic low dose exposure to carbon monoxide, CO intoxication is usually overlooked, mostly due to vague symptoms. Herein we present a 15-year-old female patient with chronic carbon monoxide poisoning who was undergoing two years of follow-up care for migraines. Chronic carbon monoxide intoxication may mimic the episodic nature and familial predisposition of migraine attacks. Normal carboxyhemoglobin levels do not exclude the diagnosis, and smoking is a confounding factor. In emergency rooms, patients presenting with headaches had higher levels of carboxyhemoglobin, but, as far as we know, there have been no studies investigating carboxyhemoglobin levels in migraine patients. Chronic carbon monoxide poisoning should be suspected in migraine patients, especially if the attacks occur during winter months. ÖZET: Primer baş ağrısında ayırıcı tanının yapılması bazen doktorlar açısından zor olabilmektedir. Literatürde karbon monoksit ile baş ağrısı arasındaki ilişki çok iyi ortaya konulmuş olmasına karşın, dirençli ve nonspesifik başağrısı nedenlerinden biri olan kronik düşük doz karbon monoksit maruziyeti kendine özgü bulgusu olmadığından sıklıkla atlanmaktadır. Bu yazıda, iki yıl migren tanısı ile takip ve tedavi edilen kronik karbon monoksit zehirlenmesi olan bir olgu sunuldu. Kronik karbon monoksit zehirlenmesi epizodik paterni ve aile fertlerinde benzer şikayetlerin olması nedeniyle migren ataklarını andırabilmektedir. Karboksihemoglobin konsantrasyonlarının normal saptanması tanıyı ekarte ettirmemekte, ayrıca sigara kullanımı da karıştırıcı bir faktör olabilmektedir. Acil servislerine baş ağrısı ile başvuran hastalar

  8. Gas-phase studies of AunOm+ interacting with carbon monoxide

    Science.gov (United States)

    Kimble, M. L.; Castleman, A. W.

    2004-04-01

    The results of reactions between preformed cationic gold oxide clusters and carbon monoxide have been investigated utilizing a fast-flow reactor mass spectrometer. From these studies, it was found that all AunOm+ produced in the cluster source disappeared with CO addition at the reactant gas inlet. Furthermore, with CO addition, intermediate peaks of the form AunOm(CO)x+ (n=1-2, m=0-3, x=0-2) were produced, with some of the species continuing to react at higher CO flows.

  9. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Science.gov (United States)

    Wu, Martin; Ren, Qinghu; Durkin, A Scott; Daugherty, Sean C; Brinkac, Lauren M; Dodson, Robert J; Madupu, Ramana; Sullivan, Steven A; Kolonay, James F; Haft, Daniel H; Nelson, William C; Tallon, Luke J; Jones, Kristine M; Ulrich, Luke E; Gonzalez, Juan M; Zhulin, Igor B; Robb, Frank T; Eisen, Jonathan A

    2005-11-01

    We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO) as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  10. Life in Hot Carbon Monoxide: The Complete Genome Sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  11. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    Martin Wu

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  12. Analysis association of milk fat and protein percent in quantitative ...

    African Journals Online (AJOL)

    Analysis association of milk fat and protein percent in quantitative trait locus ... African Journal of Biotechnology ... Protein and fat percent as content of milk are high-priority criteria for financial aims and selection of programs in dairy cattle.

  13. Impacts of Process and Prediction Uncertainties on Projected Hanford Waste Glass Amount

    Energy Technology Data Exchange (ETDEWEB)

    Gervasio, V.; Kim, D. S.; Vienna, J. D.; Kruger, A. A.

    2018-03-08

    Analyses were performed to evaluate the impacts of using the advanced glass models, constraints (Vienna et al. 2016), and uncertainty descriptions on projected Hanford glass mass. The maximum allowable waste oxide loading (WOL) was estimated for waste compositions while simultaneously satisfying all applicable glass property and composition constraints with sufficient confidence. Different components of prediction and composition/process uncertainties were systematically included in the calculations to evaluate their impacts on glass mass. The analyses estimated the production of 23,360 MT of immobilized high-level waste (IHLW) glass when no uncertainties were taken into account. Accounting for prediction and composition/process uncertainties resulted in 5.01 relative percent increase in estimated glass mass of 24,531 MT. Roughly equal impacts were found for prediction uncertainties (2.58 RPD) and composition/process uncertainties (2.43 RPD). The immobilized low-activity waste (ILAW) mass was predicted to be 282,350 MT without uncertainty and with waste loading “line” rules in place. Accounting for prediction and composition/process uncertainties resulted in only 0.08 relative percent increase in estimated glass mass of 282,562 MT. Without application of line rules the glass mass decreases by 10.6 relative percent (252,490 MT) for the case with no uncertainties. Addition of prediction uncertainties increases glass mass by 1.32 relative percent and the addition of composition/process uncertainties increase glass mass by an additional 7.73 relative percent (9.06 relative percent increase combined). The glass mass estimate without line rules (275,359 MT) was 2.55 relative percent lower than that with the line rules (282,562 MT), after accounting for all applicable uncertainties.

  14. Ratio of carbon monoxide to molecular hydrogen in interstellar dark clouds

    International Nuclear Information System (INIS)

    Dickman, R.L.; Rensselaer Polytechnic Institute; and The Ivan A. Getting Laboratories, The Aerospace Corporation)

    1978-01-01

    Carbon monoxide and molecular hydrogen column densities are compared at various locations within 38 interstellar dark clouds. CO column densities were obtained from radio observations of the J=1→0 transitions of the 12 C 16 O and 13 C 16 O isotopic species of the molecule. Corresponding H 2 column densities were inferred by means of visual extinctions derived from star counts, since it is argued that the standard gas-to-extinction ratio can be expected to remain valid in the clouds studied. For locations in the sources possessing line-of-sight visual extinctions in the approximate range 1.5 -2 ) = (5.0 +- 2.5) x 10 5 N 13 between molecular hydrogen and 13 CO LTE column densities. The carbon monoxide molecule can therefore be used as a quantitative ''tracer'' for the (directly unobservable) H 2 content of dark clouds. The above relationship implies that at least approx.12% of the gas-phase carbon in the clouds studied is in the form of CO, provided that the clouds are assumed to be chemically homogeneous. Langer's ion-molecule chemistry for dark clouds appears to agree well with the present work if the fractionation channel of Watson, Anicich, and Huntress is included

  15. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Science.gov (United States)

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  16. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  17. Serum Predictors of Percent Lean Mass in Young Adults.

    Science.gov (United States)

    Lustgarten, Michael S; Price, Lori L; Phillips, Edward M; Kirn, Dylan R; Mills, John; Fielding, Roger A

    2016-08-01

    Lustgarten, MS, Price, LL, Phillips, EM, Kirn, DR, Mills, J, and Fielding, RA. Serum predictors of percent lean mass in young adults. J Strength Cond Res 30(8): 2194-2201, 2016-Elevated lean (skeletal muscle) mass is associated with increased muscle strength and anaerobic exercise performance, whereas low levels of lean mass are associated with insulin resistance and sarcopenia. Therefore, studies aimed at obtaining an improved understanding of mechanisms related to the quantity of lean mass are of interest. Percent lean mass (total lean mass/body weight × 100) in 77 young subjects (18-35 years) was measured with dual-energy x-ray absorptiometry. Twenty analytes and 296 metabolites were evaluated with the use of the standard chemistry screen and mass spectrometry-based metabolomic profiling, respectively. Sex-adjusted multivariable linear regression was used to determine serum analytes and metabolites significantly (p ≤ 0.05 and q ≤ 0.30) associated with the percent lean mass. Two enzymes (alkaline phosphatase and serum glutamate oxaloacetate aminotransferase) and 29 metabolites were found to be significantly associated with the percent lean mass, including metabolites related to microbial metabolism, uremia, inflammation, oxidative stress, branched-chain amino acid metabolism, insulin sensitivity, glycerolipid metabolism, and xenobiotics. Use of sex-adjusted stepwise regression to obtain a final covariate predictor model identified the combination of 5 analytes and metabolites as overall predictors of the percent lean mass (model R = 82.5%). Collectively, these data suggest that a complex interplay of various metabolic processes underlies the maintenance of lean mass in young healthy adults.

  18. Non-intentional motor vehicle-related carbon monoxide deaths-revisited

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, A.R.

    1986-01-01

    A study of non-intentional, motor vehicle-related, carbon monoxide-related deaths was performed on the case files of the Office of the Medical Examiner of Metropolitan Dade Country in Miami, FL (USA) during the years 1980-1984. A total of 15 cases were collected during that time period. These are presented in some detail. A discussion ensues that compares the similar circumstances of these cases, notably running the engine of an automobile in an enclosed space, with older reports in the literature which emphasized defective vehicle exhaust systems as the leading etiology for these deaths.

  19. Measurements of Carbon Dioxide, Carbon Monoxide, and Other Related Tracers at High Spatial and Temporal Resolution in an Urban Environment

    Science.gov (United States)

    Rella, C.; Jacobson, G.

    2012-04-01

    The ability to quantify the sources and sinks of carbon dioxide on the urban scale is essential for understanding the atmospheric drivers to global climate change. In the 'top-down' approach, overall carbon fluxes are determined by combining remote measurements of carbon dioxide concentrations with complex atmospheric transport models, and these emissions measurements are compared to "bottoms-up" predictions based on detailed inventories of the sources and sinks of carbon, both anthropogenic and biogenic in nature. This approach, which has been proven to be effective at continental scales, becomes challenging to implement at the urban scale, due to poorly understood micrometeorological atmospheric transport models and high variability of the emissions sources in space (e.g., factories, highways, residences) and time (rush hours, factory shifts and shutdowns, residential energy usage variability during the day and over the year). New measurement and analysis techniques are required to make sense of the carbon dioxide signal in cities. Here we present detailed, high spatial- and temporal-resolution greenhouse gas measurements in Silicon Valley in California. The synthesis of two experimental campaigns is presented: real-time measurements from two ten-meter urban 'towers,' and ground-based mobile mapping measurements. Real-time carbon dioxide data from a nine-month period are combined with real-time carbon monoxide, methane, acetylene, and carbon 13 measurements to partition the observed CO2 concentrations between different anthropogenic sectors (e.g., transport, residential) and biogenic sources. The carbon monoxide to carbon dioxide ratio is shown to vary over more than a factor of two from season to season or even from day to night, indicating rapid and frequent shifts in the balance between different carbon dioxide sources. Clear differences are seen between the two urban sites, which are separated by 7 km. Further information is given by the carbon 13 signature

  20. Iodine monoxide in the north subtropical free troposphere [Discussion paper

    OpenAIRE

    Puentedura, Olga; Gil-Ojeda, Manuel; Saiz-Lopez, Alfonso; Hay, Tim; Navarro Comas, Mónica; Gómez Peláez, Ángel Jesús; Cuevas Agulló, Emilio; Iglesias, J.

    2011-01-01

    Iodine monoxide (IO) was retrieved using a new multi-axis DOAS instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and is hence representative of the free troposphere. We report daily observations from May to August 2010 at different viewing angles. During this period, t...

  1. Vibrationally Excited Carbon Monoxide Produced via a Chemical Reaction Between Carbon Vapor and Oxygen

    Science.gov (United States)

    Jans, Elijah R.; Eckert, Zakari; Frederickson, Kraig; Rich, Bill; Adamovich, Igor V.

    2017-06-01

    Measurements of the vibrational distribution function of carbon monoxide produced via a reaction between carbon vapor and molecular oxygen has shown a total population inversion on vibrational levels 4-7. Carbon vapor, produced using an arc discharge to sublimate graphite, is mixed with an argon oxygen flow. The excited carbon monoxide is vibrationally populated up to level v=14, at low temperatures, T=400-450 K, in a collision-dominated environment, 15-20 Torr, with total population inversions between v=4-7. The average vibrational energy per CO molecule formed by the reaction is 0.6-1.2 eV/molecule, which corresponds to 10-20% of the reaction enthalpy. Kinetic modeling of the flow reactor, including state specific vibrational processes, was performed to infer the vibrational distribution of the products of the reaction. The results show viability of developing of a new chemical CO laser from the reaction of carbon vapor and oxygen.

  2. Computed tomography of delayed encephalopathy of acute carbon monoxide poisoning - correlation with clinical findings -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Chung, Sung Hoon; Choo, In Wook; Chang, Kee Hyun

    1986-01-01

    Cerebral computed tomography (CT) findings were described in twenty-six cases with the late sequelae of acute carbon monoxide poisoning and were computed with the neurological symptoms and signs. The CT findings include symmetrical periventricular white matter low density in five cases, globes pallidus low density in six cases, ventricular dilatation in seven cases, ventricular dilatation and sulci widening in three cases, and normal findings in ten cases. Only one case showed low densities in both periventricular white matter and globes pallidus. Late sequelae of the interval from of carbon monoxide poisoning were clinically categorized as cortical dysfunction, parkinsonian feature, and cerebella dysfunction. The severity of the clinical symptoms and signs of neurological sequelae is generally correlated with presence and multiplicity of abnormal brain CT findings. But of fourteen cases showing the parkinsonian feature, only five cases had low density of globes pallidus in brain CT. Another case showing small unilateral low density of globes pallidus had no parkinsonian feature but showed mild cortical dysfunction.

  3. The chest X-ray in pulmonary capillary haemorrhage: correlation with carbon monoxide uptake

    International Nuclear Information System (INIS)

    Bowley, N.B.; Hughes, J.M.B.; Steiner, R.E.

    1979-01-01

    Serial changes in carbon monoxide uptake (Ksub(CO) or Dsub(L)CO/VA) were used to monitor episodes of pulmonary capillary haemorrhage in Goodpasture's syndrome (13 cases), immune complex nephritis (three cases) and idiopathic haemosiderosis (one case). Air-space shadowing on the chest X-ray (on a scoring system 0 to 12) was assessed in the light of the changes of Ksub(CO). In 14 out of 27 episodes of bleeding, the rise and fall of Ksub(CO) was matched in time by the appearance and disappearance of air-space shadowing on the chest X-ray. In six episodes the chest X-ray remained normal despite a rise of Ksub(CO). In two cases air-space shadowing appeared up to 48 h after the rise of Ksub(CO). On five occasions chest X-ray abnormalities preceded the rise of Ksub(CO) but chest infection or fluid overload accounted for three of these. In cases with suspected pulmonary capillary haemorrhage, measurements of carbon monoxide uptake will provide additional information and will assist in the interpretation of the chest X-ray. (author)

  4. Acute carbon monoxide intoxication : the relation between MR findings and clinical outcome

    International Nuclear Information System (INIS)

    Chang, Jin Bae; Jeong, Hae Woong; Kim, Ki Nam; Kim, Dong Wook; Kim, Chang Soo

    1999-01-01

    To analyse MR findings of various involving sites and the relation between such findings and clinical outcome, the authors retrospectively reviewed MR images of acute carbon monoxide intoxication. In 12 patients, MR images obtained from several hours to 12 days after acute carbon monoxide intoxication were reviewed. The images were analysed with regard to involved sites, symmetricity, signal intensity, and the presence or absence of hemorrhage, and the relationship between MR findings and clinical outcome; the presence of delayed encephalopathy was then determined. The globus pallidus(n=9), white matter(n=3), [centrum semiovale(n=2), periventricular white matter(n=1)] and gyrus(n=6) [inferior temporal gyrus(n=2), cingulate gyrus(n=1), precentral gyrus(n=1), hippocampal gyrus(n=1), parahippocampal gyrus(n=1)] were typically involved, and there was also involvenent of the corpus callosum(n=3), thalamus(n=2) and midbrain(n=2). All lesions of the globus pallidus, thalamus, midbrain and temporal lobe were bilaterally symmetric. In all these cases, subtle or prominent low signal intensity was seen on spin-echo T1WI, and high signal intensity on PDWI and T2WI. Some lesions of the globus pallidus(n=1), thalamus(n=1) and midbrain(n=1) were associated with hemorrhage, which occurred during the early subacute stage and was seen on high/low signal intensity T1/T2WI images. Acute cerebral(n=1) and cerebellar(n=1) infarctions were also seen. Cerebral white matter involvement correlated with poor clinical outcome, and in two cases, delayed encephalopathy developed. In these cases of acute carbon monoxide intoxication, the globus pallidus, white matter, cortex and hippocampus were frequently involved, and there was also involvement of various sites such as the corpus callosum, thalamus and midbrain. Lesions of the temporal lobe, thalamus and midbrain were bilaterally symmetric. The involvement of cerebral white matter and the presence of delayed encephalopathy can influence

  5. Room-temperature cold-welding of gold nanoparticles for enhancing the electrooxidation of carbon monoxide.

    Science.gov (United States)

    Liu, Cai; Li, Yong-Jun; Sun, Shi-Gang; Yeung, Edward S

    2011-04-21

    A cold-welding strategy is proposed to rapidly join together Au nanoparticles (AuNPs) into two-dimensional continuous structures for enhancing the electrooxidation of carbon monoxide by injecting a mixture of ethanol and tolulene into the bottom of a AuNP solution. © The Royal Society of Chemistry 2011

  6. Experimental study on surface wrinkling of silicon monoxide film on compliant substrate under thermally induced loads

    Science.gov (United States)

    Li, Chuanwei; Kong, Yingxiao; Jiang, Wenchong; Wang, Zhiyong; Li, Linan; Wang, Shibin

    2017-06-01

    The wrinkling of a silicon monoxide thin film on a compliant poly(dimethylsiloxane) (PDMS) substrate structure was experimentally investigated in this study. The self-expansion effect of PDMS during film deposition was utilized to impose a pretensile strain on the structure through a specially made fixture. A laser scanning confocal microscope (LSCM) system with an in situ heating stage was employed for the real-time measurement. The Young’s modulus of the silicon monoxide thin film as well as the PDMS substrate was measured on the basis of the elasticity theory. Moreover, the effects of temperature variations on geometric parameters in the postbuckling state, such as wavelength and amplitude, were analyzed. It was proved that wavelength is relatively immune to thermal loads, while amplitude is much more sensitive.

  7. Catalyst for Carbon Monoxide Oxidation

    Science.gov (United States)

    Davis, Patricia; Brown, Kenneth; VanNorman, John; Brown, David; Upchurch, Billy; Schryer, David; Miller, Irvin

    2010-01-01

    In many applications, it is highly desirable to operate a CO2 laser in a sealed condition, for in an open system the laser requires a continuous flow of laser gas to remove the dissociation products that occur in the discharge zone of the laser, in order to maintain a stable power output. This adds to the operating cost of the laser, and in airborne or space applications, it also adds to the weight penalty of the laser. In a sealed CO2 laser, a small amount of CO2 gas is decomposed in the electrical discharge zone into corresponding quantities of CO and O2. As the laser continues to operate, the concentration of CO2 decreases, while the concentrations of CO and O2 correspondingly increase. The increasing concentration of O2 reduces laser power, because O2 scavenges electrons in the electrical discharge, thereby causing arcing in the electric discharge and a loss of the energetic electrons required to boost CO2 molecules to lasing energy levels. As a result, laser power decreases rapidly. The primary object of this invention is to provide a catalyst that, by composition of matter alone, contains chemisorbed water within and upon its structure. Such bound moisture renders the catalyst highly active and very long-lived, such that only a small quantity of it needs to be used with a CO2 laser under ambient operating conditions. This object is achieved by a catalyst that consists essentially of about 1 to 40 percent by weight of one or more platinum group metals (Pt, Pd, Rh, Ir, Ru, Os, Pt being preferred); about 1 to 90 percent by weight of one or more oxides of reducible metals having multiple valence states (such as Sn, Ti, Mn, Cu, and Ce, with SnO2 being preferred); and about 1 to 90 percent by weight of a compound that can bind water to its structure (such as silica gel, calcium chloride, magnesium sulfate, hydrated alumina, and magnesium perchlorate, with silica gel being preferred). Especially beneficial results are obtained when platinum is present in the

  8. Analysis of carbon monoxide (CO) with Delhi Finite Line Source (DFLS) in MT Haryono Street, Medan City

    Science.gov (United States)

    Turmuzi, M.; Suryati, I.; Mashaly, E. T.; Batubara, F.

    2018-02-01

    One source to decrease urban air ambient quality is transportation sector. Important pollutants are released by gas emissions from vehicles are carbon monoxide (CO), hydrocarbons (HC), nitrogen dioxide (NO2), particulate matter and others. The presence of CO pollutants in the ambient air can be predicted by modeling air quality. This study aims to estimate CO concentration resulting from transportation activities using Delhi Finite Line Source (DFLS) model, comparing CO prediction using a DFLS model with CO observation in the field, and determine the suitability of the DFLS model application on the MT Haryono street in Medan City. Research was conducted for 3 days at two sample points with frequency twice daily. Based on research results, the range of CO concentration from observation between 22.903 μg/m3 - 27.484 μg/m3. CO observation is still below the ambient air quality standard. According to the DFLS calculations, the range of CO concentration between 1.499 μg/m3- 2.051 μg/m3. The calculation index of agreement (IOA) validation test obtained value of d = 0.22. The DFLS model is not suitable to be applied on MT Haryono street because many factors affected such as wind direction and wind velocity, ambient air temperature and humidity

  9. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao

    2017-04-12

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  10. Thermal Degradation of Lead Monoxide Filled Polymer Composite Radiation Shields

    International Nuclear Information System (INIS)

    Harish, V.; Nagaiah, N.

    2011-01-01

    Lead monoxide filled Isophthalate resin particulate polymer composites were prepared with different filler concentrations and investigated for physical, thermal, mechanical and gamma radiation shielding characteristics. This paper discusses about the thermo gravimetric analysis of the composites done to understand their thermal properties especially the effect of filler concentration on the thermal stability and degradation rate of composites. Pristine polymer exhibits single stage degradation whereas filled composites exhibit two stage degradation processes. Further, the IDT values as well as degradation rates decrease with the increased filler content in the composite.

  11. Chlorination of niobium oxide in the presence of carbon monoxide

    International Nuclear Information System (INIS)

    Freitas, L.R. de

    1984-01-01

    The chlorination kinetics of niobium pentoxide in the presence of carbon monoxide between 500-800 0 C of temperature is studied. The following variable that influences on the reaction rate are analysed: gas flow, geometry and volume of the Nb 2 O 5 samples, reaction temperature and composition of the chlorinated mixture. At the same time, two other materials were studied: the CaO.Nb 2 O 5 (synthetized in laboratory) and pyrochlorine concentrates. The three materials are compared for the chlorination method used. (M.A.C.) [pt

  12. Microbial fuel cell-based biosensor for toxic carbon monoxide monitoring

    DEFF Research Database (Denmark)

    Zhou, Shaofeng; Huang, Shaobin; Li, Yi

    2018-01-01

    This study presents an innovative microbial fuel cell-based biosensor for carbon monoxide (CO) monitoring. The hypothesis for the function of the biosensor is that CO inhibits bacterial activity in the anode and thereby reduces electricity production. A mature electrochemically active biofilm...... increasing CO concentration over 70%. Besides, the response time of the biosensor was 1 h. The compact design and simple operation of the biosensor makes it easy to be integrated in existing CO-based industrial facilities either as a forewarning sensor for CO toxicity or even as an individual on...

  13. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  14. 12 CFR 741.4 - Insurance premium and one percent deposit.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Insurance premium and one percent deposit. 741... Insurance premium and one percent deposit. (a) Scope. This section implements the requirements of Section... payment of an insurance premium. (b) Definitions. For purposes of this section: (1) Available assets ratio...

  15. Evidence for long-range transport of carbon monoxide in the Southern Hemisphere from SCIAMACHY observations

    NARCIS (Netherlands)

    Gloudemans, A.M.S.; Krol, M.C.; Meirink, J.F.; de Laat, A.T.J.; van der Werf, G.R.; Schrijver, H.; van den Broek, M.M.P.; Aben, I.

    2006-01-01

    The SCIAMACHY satellite instrument shows enhanced carbon monoxide (CO) columns in the Southern Hemisphere during the local Spring. Chemistry-transport model simulations using the new GFEDv2 biomass-burning emission database show a similar temporal and spatial CO distribution, indicating that the

  16. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    Science.gov (United States)

    2012-02-14

    ... a SIP means that transportation activities will not produce new air quality violations, worsen... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY... Transportation & Public Facilities, and the U.S. Department of Transportation will be required to use [[Page 8253...

  17. Exposure to carbon monoxide, respirable suspended particulates, and volatile organic compounds while commuting by bicycle

    International Nuclear Information System (INIS)

    Bevan, M.A.J.; Proctor, C.J.; Baker-Rogers, J.; Warren, N.D.

    1991-01-01

    A portable air sampling system has been used to assess exposures to various substances while commuting by bicycle in an urban area. The major source of pollutants in this situation is motor vehicle exhaust emissions. Carbon monoxide, measured by electrochemical detection, was found at peak concentrations in excess of 62 ppm, with mean values over 16 individual 35-mm journeys being 10.5 ppm. Respirable suspended particulates, averaged over each journey period, were found at higher concentrations (mean 130 μg m -3 ) than would be expected in indoor situations. Mean exposure to benzene (at 56 μg m -3 ) and other aromatic volatile organic compounds was also relatively high. The influence of wind conditions on exposure was found to be significant. Commuting exposures to carbon monoxide, respirable suspended particulates, and aromatic VOCs were found to be higher than exposures in a busy high street and on common parkland

  18. Effects of body position on the carbon monoxide diffusing capacity in patients with chronic heart failure: relation to hemodynamic changes.

    Science.gov (United States)

    Faggiano, P; D'Aloia, A; Simoni, P; Gualeni, A; Foglio, K; Ambrosino, N; Giordano, A

    1998-01-01

    Pulmonary diffusion has been found to be reduced in patients with congestive heart failure. The effects of postural changes on the diffusing capacity had been evaluated in healthy subjects, but not in patients with heart failure. The aim of this study was to evaluate the posture-induced changes in diffusing capacity in patients with chronic heart failure and their relation to the hemodynamic profile. The pulmonary carbon monoxide diffusing capacity (DLCO) was measured in the supine position, with 20 degrees passive head elevation, and in the sitting position, both postures maintained for 10 min, in a group of 32 male patients with mild to moderate chronic heart failure due to left ventricular systolic dysfunction (ejection fraction differ in the two positions (20.3 +/- 5.7 vs. 19.4 +/- 5.6 ml/min/mm Hg, 77 +/- 23 vs. 75 +/- 20% of predicted, respectively). The patients were then subdivided according to changes in DLCO from the supine to the sitting position: DLCO increased (+23%) in 9 patients (28%, group 1), decreased (-17.5%) in 17 patients (53%, group 2), and remained within the coefficient of reproducibility ( +/- 5 %) in 6 patients (group 3). As compared with group 2, group 1 patients showed a significant increase in mean pulmonary artery pressure (+7 vs. -15%, p pressure (+8 vs. -22%, p position, while the cardiac index showed a smaller - but not significant - decrease in group 1 (-5 vs. -12%). The percent changes in DLCO significantly correlated with changes in pulmonary capillary wedge (r = 0.54, p pressures. In chronic heart failure postural changes may induce different responses in diffusing capacity. To a greater extent than in healthy subjects, the most common response is a decrease in DLCO in the sitting as compared with the supine position. The DLCO changes correlate with variations in pulmonary circulation pressure, probably due to changes in pulmonary vascular recruitment and pulmonary capillary blood volume.

  19. Matter power spectrum and the challenge of percent accuracy

    International Nuclear Information System (INIS)

    Schneider, Aurel; Teyssier, Romain; Potter, Doug; Stadel, Joachim; Reed, Darren S.; Onions, Julian; Pearce, Frazer R.; Smith, Robert E.; Springel, Volker; Scoccimarro, Roman

    2016-01-01

    Future galaxy surveys require one percent precision in the theoretical knowledge of the power spectrum over a large range including very nonlinear scales. While this level of accuracy is easily obtained in the linear regime with perturbation theory, it represents a serious challenge for small scales where numerical simulations are required. In this paper we quantify the precision of present-day N -body methods, identifying main potential error sources from the set-up of initial conditions to the measurement of the final power spectrum. We directly compare three widely used N -body codes, Ramses, Pkdgrav3, and Gadget3 which represent three main discretisation techniques: the particle-mesh method, the tree method, and a hybrid combination of the two. For standard run parameters, the codes agree to within one percent at k ≤1 h Mpc −1 and to within three percent at k ≤10 h Mpc −1 . We also consider the bispectrum and show that the reduced bispectra agree at the sub-percent level for k ≤ 2 h Mpc −1 . In a second step, we quantify potential errors due to initial conditions, box size, and resolution using an extended suite of simulations performed with our fastest code Pkdgrav3. We demonstrate that the simulation box size should not be smaller than L =0.5 h −1 Gpc to avoid systematic finite-volume effects (while much larger boxes are required to beat down the statistical sample variance). Furthermore, a maximum particle mass of M p =10 9 h −1 M ⊙ is required to conservatively obtain one percent precision of the matter power spectrum. As a consequence, numerical simulations covering large survey volumes of upcoming missions such as DES, LSST, and Euclid will need more than a trillion particles to reproduce clustering properties at the targeted accuracy.

  20. UV-induced carbon monoxide emission from living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2013-01-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop...... to either an ecosystem chamber or a plant-leaf scale chamber. Leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation as well as the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature......, indicating an abiotic process. The emission of CO in response to the UV-component of natural solar radiation was also evident at the ecosystem scale....

  1. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more...

  2. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad

    2018-05-07

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm at combustion relevant conditions. Off-axis alignment and rapid intra-pulse down-chirp resulted in effective suppression of cavity noise.

  3. Catalytic Reduction of Nitrous Oxide with Carbon Monoxide over Calcined Co–Mn–Al Hydrotalcite

    Czech Academy of Sciences Publication Activity Database

    Pacultová, K.; Obalová, L.; Kovanda, F.; Jirátová, Květa

    2008-01-01

    Roč. 137, 2-4 (2008), s. 358-389 ISSN 0920-5861 R&D Projects: GA ČR(CZ) GA106/05/0366 Institutional research plan: CEZ:AV0Z40720504 Keywords : nitrous oxide * carbon monoxide * mixed oxide catalysts Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.004, year: 2008

  4. Convergence of quasiparticle self-consistent GW calculations of transition metal monoxides

    OpenAIRE

    Das, Suvadip; Coulter, John E.; Manousakis, Efstratios

    2014-01-01

    Finding an accurate ab initio approach for calculating the electronic properties of transition metal oxides has been a problem for several decades. In this paper, we investigate the electronic structure of the transition metal monoxides MnO, CoO, and NiO in their undistorted rock-salt structure within a fully iterated quasiparticle self-consistent GW (QPscGW) scheme. We study the convergence of the QPscGW method, i.e., how the quasiparticle energy eigenvalues and wavefunctions converge as a f...

  5. Residual volume on land and when immersed in water: effect on percent body fat.

    Science.gov (United States)

    Demura, Shinichi; Yamaji, Shunsuke; Kitabayashi, Tamotsu

    2006-08-01

    There is a large residual volume (RV) error when assessing percent body fat by means of hydrostatic weighing. It has generally been measured before hydrostatic weighing. However, an individual's maximal exhalations on land and in the water may not be identical. The aims of this study were to compare residual volumes and vital capacities on land and when immersed to the neck in water, and to examine the influence of the measurement error on percent body fat. The participants were 20 healthy Japanese males and 20 healthy Japanese females. To assess the influence of the RV error on percent body fat in both conditions and to evaluate the cross-validity of the prediction equation, another 20 males and 20 females were measured using hydrostatic weighing. Residual volume was measured on land and in the water using a nitrogen wash-out technique based on an open-circuit approach. In water, residual volume was measured with the participant sitting on a chair while the whole body, except the head, was submerged . The trial-to-trial reliabilities of residual volume in both conditions were very good (intraclass correlation coefficient > 0.98). Although residual volume measured under the two conditions did not agree completely, they showed a high correlation (males: 0.880; females: 0.853; P body fat computed using residual volume measured in both conditions was very good for both sexes (males: r = 0.902; females: r = 0.869, P body fat: -3.4 to 2.2% for males; -6.3 to 4.4% for females). We conclude that if these errors are of no importance, residual volume measured on land can be used when assessing body composition.

  6. Determining the diagnostic value of endogenous carbon monoxide in Chronic Obstructive Pulmonary Disease exacerbations

    International Nuclear Information System (INIS)

    Dogan, N. O.; Corbacioglu, S. K.; Bildik, F.; Kilicaslan, I.; Hakoglu, O.; Gunaydin, G. P.; Cevik, Y.; Ulker, V.; Gokcen, E.

    2014-01-01

    Objective: To determine whether endogenous carbon monoxide levels in exacerbations of Chronic Obstructive Pulmonary Disease patients were higher compared to healthy individuals and to investigate alteration of carbon monoxide levels across the three different severity stages of Global Initiative for Chronic Obstructive Lung Disease criteria related to Chronic Obstructive Pulmonary Disease exacerbations. Methods: The prospective study was conducted from January to March 2011 at two medical institutions in Ankara, Turkey, and comprised patients of acute Chronic Obstructive Pulmonary Disease exacerbations. The severity of the exacerbations was based on the Global Initiative for Chronic Obstructive Lung Disease criteria. Patients with active tobacco smoking, suspicious carbon monoxide poisoning and uncertain diagnosis were excluded. healthy control subjects who did not have any comorbid diseases and smoking habitus were also enrolled to compare the differences between carboxyhaemoglobin levels A two-tailed Mann-Whitney U test with Bonferroni correction was done following a Kruskal-Wallis test for statistical purposes. Results: There were 90 patients and 81 controls in the study. Carboxyhaemoglobin levels were higher in the patients than the controls (p<0.001). As for the three severity stages, Group 1 had a median carboxyhaemoglobin of 1.6 (0.95-2.00). The corresponding levels in Group 2 (1.8 (1.38-2.20)) and Group 3 (1.9 (1.5-3.0)) were higher than the controls (p<0.001 and p<0.005 respectively). No statistically significant difference between Group 1 and the controls (1.30 (1.10-1.55)) was observed (p<0.434). Conclusion: Carboxyhaemoglobin levels were significantly higher in exacerbations compared with the normal population. Also, in more serious exacerbations, carboxyhaemoglobin levels were significantly increased compared with healthy individuals and mild exacerbations. (author)

  7. Variations of time-to-incapacitation and carboxyhemoglobin values in rats exposed to two carbon monoxide concentrations.

    Science.gov (United States)

    1993-05-01

    It has been suggested that passenger protective breathing equipment protect aircraft passengers from smoke for 5 min during an evacuation phase and for 35 min during an in-flight-plus-evacuation phase. Carbon monoxide (CO) is one of the most abundant...

  8. Carbon monoxide budget in the northern hemisphere

    Energy Technology Data Exchange (ETDEWEB)

    Bakwin, P.S.; Tans, P.P. (Climate Monitoring and Diagnostics Lab., Boulder, CO (United States)); Novelli, P.C. (Univ. of Colorado, Boulder, CO (United States))

    1994-03-15

    To improve urban air quality the major industrialized nations of the West took steps during the 1970s and 1980s to reduce carbon monoxide (CO) emissions from automobiles and other industrial sources. Overall, CO/CO[sub 2] emission ratios from the mix of fossil fuel combustion sources have been reduced by about half during 1976-1990. Also, the tropospheric abundance of hydroxyl radical (OH), which is the main sink for CO, is proposed to have increased globally by about 1.0 [+-] 0.8% yr[sup [minus]1]. The authors use a simple two-box model to examine the impact of shrinking emissions and increasing OH on the global abundance of CO. They find that these factors contribute about equally in reducing CO levels in the Northern Hemisphere troposphere by about 1.8 [+-] 0.8 ppb yr[sup [minus]1] on average. 19 refs., 1 fig.

  9. Hydrothermal Synthesis of Pt-, Fe-, and Zn-doped SnO2 Nanospheres and Carbon Monoxide Sensing Properties

    Directory of Open Access Journals (Sweden)

    Weigen Chen

    2013-01-01

    Full Text Available Pure and M-doped (M = Pt, Fe, and Zn SnO2 nanospheres were successfully synthesized via a simple and facile hydrothermal method and characterized by X-ray powder diffraction, field-emission scanning electron microscopy, and energy dispersive spectroscopy. Chemical gas sensors were fabricated based on the as-synthesized nanostructures, and carbon monoxide sensing properties were systematically measured. Compared to pure, Fe-, and Zn-doped SnO2 nanospheres, the Pt-doped SnO2 nanospheres sensor exhibits higher sensitivity, lower operating temperature, more rapid response and recovery, better stability, and excellent selectivity. In addition, a theoretical study based on the first principles calculation was conducted. All results demonstrate the potential of Pt dopant for improving the gas sensing properties of SnO2-based sensors to carbon monoxide.

  10. Determination of volumetric gas-liquid mass transfer coefficient of carbon monoxide in a batch cultivation system using kinetic simulations.

    Science.gov (United States)

    Jang, Nulee; Yasin, Muhammad; Park, Shinyoung; Lovitt, Robert W; Chang, In Seop

    2017-09-01

    A mathematical model of microbial kinetics was introduced to predict the overall volumetric gas-liquid mass transfer coefficient (k L a) of carbon monoxide (CO) in a batch cultivation system. The cell concentration (X), acetate concentration (C ace ), headspace gas (N co and [Formula: see text] ), dissolved CO concentration in the fermentation medium (C co ), and mass transfer rate (R) were simulated using a variety of k L a values. The simulated results showed excellent agreement with the experimental data for a k L a of 13/hr. The C co values decreased with increase in cultivation times, whereas the maximum mass transfer rate was achieved at the mid-log phase due to vigorous microbial CO consumption rate higher than R. The model suggested in this study may be applied to a variety of microbial systems involving gaseous substrates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Effect of Carbon Monoxide on Active Oxygen Metabolism of Postharvest Jujube

    OpenAIRE

    Shaoying Zhang; Qin Li; Yulan Mao

    2014-01-01

    To prolong the shelf life postharvest jujube, the effect of carbon monoxide (CO) on senescence of postharvest jujube in relation to active oxygen metabolism was investigated. Jujubes were fumigated with CO gas at 5, 10, 20 or 40μmol/L for 1 h, and then stored for 30 days at room temperature. Changes in membrane permeability, malonaldehyde (MDA), H2O2, O2•− content, and activities of active oxygen metabolism associated enzymes including superoxide dismutase (SOD), catalase (CAT) and peroxidase...

  12. Predicting Persistence and Withdrawal of Open Admissions Students at Virginia State University.

    Science.gov (United States)

    Tambe, Joseph T.

    1984-01-01

    A study of persistence/dropout among open admissions college students found: (1) accurate predictions cannot be made for individual students at the time of matriculation; and (2) it is possible to predict that about 80 percent of future groups will fall in the persist category after two semesters, 51 percent after four semesters. (CMG)

  13. A Southern Hemisphere atmospheric history of carbon monoxide from South Pole firn air

    Science.gov (United States)

    Verhulst, K. R.; Aydin, M.; Novelli, P. C.; Holmes, C. D.; Prather, M. J.; Saltzman, E. S.

    2013-12-01

    Carbon monoxide (CO) is a reactive trace gas and is important to tropospheric photochemistry as a major sink of hydroxyl radicals (OH). Major sources of CO are fossil fuel combustion, linked mostly to automotive emissions, biomass burning, and oxidation of atmospheric methane. Understanding changes in carbon monoxide over the past century will improve our understanding of man's influence on the reactivity of the atmosphere. Little observational information is available about CO levels and emissions prior to the 1990s, particularly for the Southern Hemisphere. The NOAA global flask network provides the most complete instrumental record of CO, extending back to 1988. Annually averaged surface flask measurements suggest atmospheric CO levels at South Pole were relatively stable from 2004-2009 at about 51 nmol mol-1 [Novelli and Masarie, 2013]. In this study, a 20th century atmospheric history of CO is reconstructed from South Pole firn air measurements, using a 1-D firn air diffusion model. Firn air samples were collected in glass flasks from two adjacent holes drilled from the surface to 118 m at South Pole, Antarctica during the 2008/2009 field season and CO analysis was carried out by NOAA/CCG. Carbon monoxide levels increase from about 45 nmol mol-1 in the deepest firn sample at 116 m to 52 nmol mol-1 at 107 m, and remain constant at about 51-52 nmol mol-1 at shallower depths. Atmospheric histories based on the firn air reconstructions suggest that CO levels over Antarctica increased by roughly 40% (from about 36 to 50 nmol mol-1) between 1930-1990, at a rate of about 0.18 nmol mol-1 yr-1. Firn air and surface air results suggest the rate of CO increase at South Pole slowed considerably after 1990. The firn air-based atmospheric history is used to infer changes in Southern Hemisphere CO emissions over the 20th century.

  14. Matter power spectrum and the challenge of percent accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Aurel; Teyssier, Romain; Potter, Doug; Stadel, Joachim; Reed, Darren S. [Institute for Computational Science, University of Zurich, Winterthurerstrasse 190, 8057 Zurich (Switzerland); Onions, Julian; Pearce, Frazer R. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Smith, Robert E. [Department of Physics and Astronomy, University of Sussex, Brighton, BN1 9QH (United Kingdom); Springel, Volker [Heidelberger Institut für Theoretische Studien, 69118 Heidelberg (Germany); Scoccimarro, Roman, E-mail: aurel@physik.uzh.ch, E-mail: teyssier@physik.uzh.ch, E-mail: dpotter@physik.uzh.ch, E-mail: stadel@physik.uzh.ch, E-mail: julian.onions@nottingham.ac.uk, E-mail: reed@physik.uzh.ch, E-mail: r.e.smith@sussex.ac.uk, E-mail: volker.springel@h-its.org, E-mail: Frazer.Pearce@nottingham.ac.uk, E-mail: rs123@nyu.edu [Center for Cosmology and Particle Physics, Department of Physics, New York University, NY 10003, New York (United States)

    2016-04-01

    Future galaxy surveys require one percent precision in the theoretical knowledge of the power spectrum over a large range including very nonlinear scales. While this level of accuracy is easily obtained in the linear regime with perturbation theory, it represents a serious challenge for small scales where numerical simulations are required. In this paper we quantify the precision of present-day N -body methods, identifying main potential error sources from the set-up of initial conditions to the measurement of the final power spectrum. We directly compare three widely used N -body codes, Ramses, Pkdgrav3, and Gadget3 which represent three main discretisation techniques: the particle-mesh method, the tree method, and a hybrid combination of the two. For standard run parameters, the codes agree to within one percent at k ≤1 h Mpc{sup −1} and to within three percent at k ≤10 h Mpc{sup −1}. We also consider the bispectrum and show that the reduced bispectra agree at the sub-percent level for k ≤ 2 h Mpc{sup −1}. In a second step, we quantify potential errors due to initial conditions, box size, and resolution using an extended suite of simulations performed with our fastest code Pkdgrav3. We demonstrate that the simulation box size should not be smaller than L =0.5 h {sup −1}Gpc to avoid systematic finite-volume effects (while much larger boxes are required to beat down the statistical sample variance). Furthermore, a maximum particle mass of M {sub p}=10{sup 9} h {sup −1}M{sub ⊙} is required to conservatively obtain one percent precision of the matter power spectrum. As a consequence, numerical simulations covering large survey volumes of upcoming missions such as DES, LSST, and Euclid will need more than a trillion particles to reproduce clustering properties at the targeted accuracy.

  15. United States home births increase 20 percent from 2004 to 2008.

    Science.gov (United States)

    MacDorman, Marian F; Declercq, Eugene; Mathews, T J

    2011-09-01

    After a gradual decline from 1990 to 2004, the percentage of births occurring at home increased from 2004 to 2008 in the United States. The objective of this report was to examine the recent increase in home births and the factors associated with this increase from 2004 to 2008. United States birth certificate data on home births were analyzed by maternal demographic and medical characteristics. In 2008, there were 28,357 home births in the United States. From 2004 to 2008, the percentage of births occurring at home increased by 20 percent from 0.56 percent to 0.67 percent of United States births. This rise was largely driven by a 28 percent increase in the percentage of home births for non-Hispanic white women, for whom more than 1 percent of births occur at home. At the same time, the risk profile for home births has been lowered, with substantial drops in the percentage of home births of infants who are born preterm or at low birthweight, and declines in the percentage of home births that occur to teen and unmarried mothers. Twenty-seven states had statistically significant increases in the percentage of home births from 2004 to 2008; only four states had declines. The 20 percent increase in United States home births from 2004 to 2008 is a notable development that will be of interest to practitioners and policymakers. (BIRTH 38:3 September 2011). © 2011, Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc.

  16. Carbon monoxide (CO) intoxication: Computerized tomography and magnetic resonance

    International Nuclear Information System (INIS)

    Benitez Gomez, S.; Aguilera Navarro, J.M.; Gonzalez Garcia, A.; Gonzalez Marcos, J.R.; Fernandez Cruz, J.

    1993-01-01

    We present a case of acute carbon monoxide (CO) intoxication in a previously healthy 13-year-old girl, who was found in the bathroom, unconscious and with the gas-burning hot water thank operating. The neuroradiological study showed bilateral, symmetrical cortical and subcortical parietooccipital and temporal lesions as well as damage to the basal lymph nodes. These lesions were related to the anoxic situation induced by this type of intoxication. Clinicoradiological follow-up included CT and MR sequences over a period of 10 months. In this cases, we stress the greater sensitivity of MR in the early detection of the characteristic lesions in this situation and we analyze the evolution of the process. (Author)

  17. Electrocatalytic oxidation of carbon monoxide

    Directory of Open Access Journals (Sweden)

    Manuel de Jesus Santiago Farias

    2009-01-01

    Full Text Available Este trabalho discute alguns aspectos importantes relacionados à reação de eletrooxidação do monóxido de carbono sobre monocristais de platina, em meio ácido. Aspectos mecanísticos são discutidos em termos da formação das estruturas compactas que o CO forma quando este é adsorvido. As principais idéias aqui apresentadas, levam em consideração as existências dessas estruturas. Os clássicos mecanismos Lagmuir-Hinshelwood e Eley-Rideal são aqui discutidos, especialmente o primeiro considerando a mobilidade do CO e também a nucleação e crescimento de ilhas formadas por espécies adsorvidas contendo oxigênio.////////// This work discusses some important aspects related to the carbon monoxide electrooxidation reaction on Pt single crystal electrodes in acidic media. The mechanistic aspects are discussed in terms of the formation of compact structures developed when CO is adsorbed. The main ideas presented here are focused on the mechanistic aspects that take into account the existence of such structures. The classical kinetic mechanisms of Lagmuir-Hinshelwood and Eley-Rideal are discussed considering the superficial mobility of CO or nucleation-growing of islands formed by oxygen-containing adsorbates.

  18. Cheatgrass percent cover change: Comparing recent estimates to climate change − Driven predictions in the Northern Great Basin

    Science.gov (United States)

    Boyte, Stephen P.; Wylie, Bruce K.; Major, Donald J.

    2016-01-01

    Cheatgrass (Bromus tectorum L.) is a highly invasive species in the Northern Great Basin that helps decrease fire return intervals. Fire fragments the shrub steppe and reduces its capacity to provide forage for livestock and wildlife and habitat critical to sagebrush obligates. Of particular interest is the greater sage grouse (Centrocercus urophasianus), an obligate whose populations have declined so severely due, in part, to increases in cheatgrass and fires that it was considered for inclusion as an endangered species. Remote sensing technologies and satellite archives help scientists monitor terrestrial vegetation globally, including cheatgrass in the Northern Great Basin. Along with geospatial analysis and advanced spatial modeling, these data and technologies can identify areas susceptible to increased cheatgrass cover and compare these with greater sage grouse priority areas for conservation (PAC). Future climate models forecast a warmer and wetter climate for the Northern Great Basin, which likely will force changing cheatgrass dynamics. Therefore, we examine potential climate-caused changes to cheatgrass. Our results indicate that future cheatgrass percent cover will remain stable over more than 80% of the study area when compared with recent estimates, and higher overall cheatgrass cover will occur with slightly more spatial variability. The land area projected to increase or decrease in cheatgrass cover equals 18% and 1%, respectively, making an increase in fire disturbances in greater sage grouse habitat likely. Relative susceptibility measures, created by integrating cheatgrass percent cover and temporal standard deviation datasets, show that potential increases in future cheatgrass cover match future projections. This discovery indicates that some greater sage grouse PACs for conservation could be at heightened risk of fire disturbance. Multiple factors will affect future cheatgrass cover including changes in precipitation timing and totals and

  19. An infrared spectroscopic study of the adsorption of carbon monoxide on silica-supported copper particles

    NARCIS (Netherlands)

    Jong, K.P. de; Geus, John W.; Joziasse, J.

    Infrared spectroscopy is used to study the adsorption of carbon monoxide (20°C; 0.1– 100 Torr) on copper-on-silica catalysts differently prepared and pretreated. As determined by electron microscopy and X-ray line broadening, the catalysts contain copper particles having sizes of 60 to 5000 Å

  20. Angiotensin-Converting Inhibitors and Angiotensin II Receptor Blockers and Longitudinal Change in Percent Emphysema on Computed Tomography. The Multi-Ethnic Study of Atherosclerosis Lung Study

    Science.gov (United States)

    Parikh, Megha A.; Aaron, Carrie P.; Hoffman, Eric A.; Schwartz, Joseph E.; Madrigano, Jaime; Austin, John H. M.; Lovasi, Gina; Watson, Karol; Stukovsky, Karen Hinckley

    2017-01-01

    Rationale: Although emphysema on computed tomography (CT) is associated with increased morbidity and mortality in patients with and without spirometrically defined chronic obstructive pulmonary disease, no available medications target emphysema outside of alpha-1 antitrypsin deficiency. Transforming growth factor-β and endothelial dysfunction are implicated in emphysema pathogenesis, and angiotensin II receptor blockers (ARBs) inhibit transforming growth factor-β, improve endothelial function, and restore airspace architecture in murine models. Evidence in humans is, however, lacking. Objectives: To determine whether angiotensin-converting enzyme (ACE) inhibitor and ARB dose is associated with slowed progression of percent emphysema by CT. Methods: The Multi-Ethnic Study of Atherosclerosis researchers recruited participants ages 45–84 years from the general population from 2000 to 2002. Medication use was assessed by medication inventory. Percent emphysema was defined as the percentage of lung regions less than −950 Hounsfield units on CTs. Mixed-effects regression models were used to adjust for confounders. Results: Among 4,472 participants, 12% used an ACE inhibitor and 6% used an ARB at baseline. The median percent emphysema was 3.0% at baseline, and the rate of progression was 0.64 percentage points over a median of 9.3 years. Higher doses of ACE or ARB were independently associated with a slower change in percent emphysema (P = 0.03). Over 10 years, in contrast to a predicted mean increase in percent emphysema of 0.66 percentage points in those who did not take ARBs or ACE inhibitors, the predicted mean increase in participants who used maximum doses of ARBs or ACE inhibitors was 0.06 percentage points (P = 0.01). The findings were of greatest magnitude among former smokers (P emphysema. There was no evidence that ACE inhibitor or ARB dose was associated with decline in lung function. Conclusions: In a large population-based study, ACE

  1. [Estimation of carbon monoxide poisonings frequency, based on carboxyhemoglobin determinations performed in Toxicology Laboratory in Krakow in years 2002-2010].

    Science.gov (United States)

    Gomółka, Ewa; Gawlikowski, Tomasz

    2011-01-01

    Carboxyhemoglobin is a specific biomarker of carbon monoxide (CO) exposition. The source of CO indoors are most often gas, oil or carbon furnaces and stoves or bathroom gas heaters. CO intoxication during fire or exposition to car fumes are sporadic. The aim of the study was: to present the frequency of CO intoxications diagnosed in Laboratory of Analytical Toxicology UJ Collegium Medicum in years 2002 - 2010, to present the season trends of CO intoxications, show sex and age structure of CO intoxicated patients. Material were Laboratory of Analytical Toxicology and Drug Monitoring data records from years 2002 - 2010. CO intoxication was confirmed and recognized when COHb blood concentration was higher than 10%. Annual number of CO poisonings was stable in the period of time, varied from 209 to 296 (mean 256,2 CO poisonings per year). Sex structure of CO poisoned patients showed little female dominance (54.6%). Carbon monoxide poisonings distribution was seasonal. The season of intensified CO intoxications lasted from October to March, the highest intensity was in December and January. The CO poisoning problem is still actual. Society education about security, recognition, diagnosis and practice in carbon monoxide exposition is still needful.

  2. How I Love My 80 Percenters

    Science.gov (United States)

    Maturo, Anthony J.

    2002-01-01

    Don't ever take your support staff for granted. By support staff, I mean the people in personnel, logistics, and finance; the ones who can make things happen with a phone call or a signature, or by the same token frustrate you to no end by their inaction; these are people you must depend on. I've spent a lot of time thinking about how to cultivate relationships with my support staff that work to the advantage of both of us. The most important thing that have learned working with people, any people--and I will tell you how I learned this in a minute--is there are some folks you just can't motivate, so forget it, don't try; others you certainly can with a little psychology and some effort; and the best of the bunch, what I call the 80 percenters, you don't need to motivate because they're already on the team and performing beautifully. The ones you can't change are rocks. Face up to it, and just kick them out of your way. I have a reputation with the people who don't want to perform or be part of the team. They don't come near me. If someone's a rock, I pick up on it right away, and I will walk around him or her to find someone better. The ones who can be motivated I take time to nurture. I consider them my projects. A lot of times these wannabes are people who want to help but don't know how. Listen, you can work with them. Lots of people in organizations have the mindset that all that matters are the regulations. God forbid if you ever work outside those regulations. They've got one foot on that regulation and they're holding it tight like a baby holds a blanket. What you're looking for is that first sign that their minds are opening. Usually you hear it in their vocabulary. What used to sound like "We can't do that ... the regulations won't allow it ... we have never done this before," well, suddenly that changes to "We have options ... let's take a look at the options ... let me research this and get back to you." The 80 percenters you want to nurture too, but

  3. Predicting big bang deuterium

    Energy Technology Data Exchange (ETDEWEB)

    Hata, N.; Scherrer, R.J.; Steigman, G.; Thomas, D.; Walker, T.P. [Department of Physics, Ohio State University, Columbus, Ohio 43210 (United States)

    1996-02-01

    We present new upper and lower bounds to the primordial abundances of deuterium and {sup 3}He based on observational data from the solar system and the interstellar medium. Independent of any model for the primordial production of the elements we find (at the 95{percent} C.L.): 1.5{times}10{sup {minus}5}{le}(D/H){sub {ital P}}{le}10.0{times}10{sup {minus}5} and ({sup 3}He/H){sub {ital P}}{le}2.6{times}10{sup {minus}5}. When combined with the predictions of standard big bang nucleosynthesis, these constraints lead to a 95{percent} C.L. bound on the primordial abundance deuterium: (D/H){sub best}=(3.5{sup +2.7}{sub {minus}1.8}){times}10{sup {minus}5}. Measurements of deuterium absorption in the spectra of high-redshift QSOs will directly test this prediction. The implications of this prediction for the primordial abundances of {sup 4}He and {sup 7}Li are discussed, as well as those for the universal density of baryons. {copyright} {ital 1996 The American Astronomical Society.}

  4. Ambient carbon monoxide associated with alleviated respiratory inflammation in healthy young adults

    International Nuclear Information System (INIS)

    Zhao, Zhuohui; Chen, Renjie; Lin, Zhijing; Cai, Jing; Yang, Yingying; Yang, Dandan; Norback, Dan; Kan, Haidong

    2016-01-01

    There is increasing controversy on whether acute exposure to ambient carbon monoxide (CO) is hazardous on respiratory health. We therefore performed a longitudinal panel study to evaluate the acute effects of ambient CO on fractional exhaled nitric oxide (FeNO), a well-established biomarker of airway inflammation. We completed 4–6 rounds of health examinations among 75 healthy young adults during April to June in 2013 in Shanghai, China. We applied the linear mixed-effect model to investigate the short-term associations between CO and FeNO. CO exposure during 2–72 h preceding health tests was significantly associated with decreased FeNO levels. For example, an interquartile range increase (0.3 mg/m"3) of 2-h CO exposure corresponded to 10.6% decrease in FeNO. This association remained when controlling for the concomitant exposure to co-pollutants. This study provided support that short-term exposure to ambient CO might be related with reduced levels of FeNO, a biomarker of lower airway inflammation. - Highlights: • We completed 4–6 rounds of health examinations among 75 healthy young adults. • Short-term CO exposure was significantly associated with decreased FeNO levels. • The inverse association between CO and FeNO was robust controlling for co-pollutants. - Short-term exposure to ambient carbon monoxide may alleviate the respiratory inflammation.

  5. IR Laser Ablation of Silicon Monoxide in Gaseous Methanol and Hydrocarbons: Deposition of Polyoxocarbosilane

    Czech Academy of Sciences Publication Activity Database

    Dřínek, Vladislav; Bastl, Zdeněk; Šubrt, Jan; Pola, Josef

    2004-01-01

    Roč. 71, č. 2 (2004), s. 431-444 ISSN 0165-2370 R&D Projects: GA ČR GA203/00/1288 Institutional research plan: CEZ:AV0Z4072921; CEZ:AV0Z4032918; CEZ:AV0Z4040901 Keywords : silicon monoxide * reactive laser ablation * polyoxocarbosilane coatings Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 1.352, year: 2004

  6. Carbon monoxide inhibits omega-oxidation of leukotriene B4 by human polymorphonuclear leukocytes: evidence that catabolism of leukotriene B4 is mediated by a cytochrome P-450 enzyme.

    Science.gov (United States)

    Shak, S; Goldstein, I M

    1984-09-17

    Carbon monoxide significantly inhibits omega-oxidation of exogenous leukotriene B4 to 20-OH-leukotriene B4 and 20-COOH-leukotriene B4 by unstimulated polymorphonuclear leukocytes as well as omega-oxidation of leukotriene B4 that is generated when cells are stimulated with the calcium ionophore, A23187. Inhibition of omega-oxidation by carbon monoxide is concentration-dependent, completely reversible, and specific. Carbon monoxide does not affect synthesis of leukotriene B4 by stimulated polymorphonuclear leukocytes or other cell functions (i.e., degranulation, superoxide anion generation). These findings suggest that a cytochrome P-450 enzyme in human polymorphonuclear leukocytes is responsible for catabolizing leukotriene B4 by omega-oxidation.

  7. Thermodynamic properties of liquid mixtures of carbon monoxide and methane

    Energy Technology Data Exchange (ETDEWEB)

    Calado, J.C.G.; Guedes, H.J.R.; Nunes da Ponte, M.; Streett, W.B.

    1984-04-01

    Researchers conducted pressure-volume-temperature measurements of liquid methane at -230/sup 0/F and of six liquid mixtures of carbon monoxide and methane at -250/sup 0/, -240/sup 0/, and -230/sup 0/F from just above the saturation vapor pressure to the freezing pressure of methane. The excess volume proved to be large and negative at low pressures but less negative as the pressure increased, being almost zero at the highest pressure. Of the thermodynamic functions, excess enthalpy and excess entropy were much more sensitive to pressure than excess Gibbs energy. Conformal solution theory in the van der Waals one-fluid form reproduced the experimental results very successfully.

  8. Analysis of carbon monoxide production in multihundred-watt heat sources

    International Nuclear Information System (INIS)

    Peterson, D.E.; Mulford, R.N.R.

    1976-05-01

    The production of carbon monoxide observed within Multihundred Watt heat sources placed under storage conditions was analyzed. Results of compositional and isotopic analyses of gas taps performed on eight heat sources are summarized and interpreted. Several proposed CO generation mechanisms are examined theoretically and assessed by applying thermodynamic principles. Outgassing of the heat source graphite followed by oxygen isotopic exchange through the vent assemblies appears to explain the CO production at storage temperatures. Reduction of the plutonia fuel sphere by the CO is examined as a function of temperature and stoichiometry. Experiments that could be performed to investigate possible CO generation mechanisms are discussed

  9. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kaminaga, Kenichi; Sei, Ryosuke [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan); Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hayashi, Kouichi [Department of Environmental and Materials Engineering, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Happo, Naohisa [School of Information Sciences, Hiroshima City University, Hiroshima 731-3194 (Japan); Tajiri, Hiroo [Japan Synchrotron Radiation Research Institute (JASRI)/SPring-8, Sayo 679-5198 (Japan); Oka, Daichi; Fukumura, Tomoteru, E-mail: tomoteru.fukumura.e4@tohoku.ac.jp [Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hasegawa, Tetsuya [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan)

    2016-03-21

    Rare earth oxides are usually widegap insulators like Y{sub 2}O{sub 3} with closed shell trivalent rare earth ions. In this study, solid phase rock salt structure yttrium monoxide, YO, with unusual valence of Y{sup 2+} (4d{sup 1}) was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO has been recognized as gaseous phase in previous studies. In contrast with Y{sub 2}O{sub 3}, YO was dark-brown colored and narrow gap semiconductor. The tunable electrical conductivity ranging from 10{sup −1} to 10{sup 3} Ω{sup −1 }cm{sup −1} was attributed to the presence of oxygen vacancies serving as electron donor. Weak antilocalization behavior observed in magnetoresistance indicated significant role of spin-orbit coupling as a manifestation of 4d electron carrier.

  10. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  11. Characteristics of autoignited laminar lifted flames in heated coflow jets of carbon monoxide/hydrogen mixtures

    KAUST Repository

    Choi, Byungchul

    2012-06-01

    The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process. © 2012 The Korean Society of Mechanical Engineers.

  12. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 1 (SRL1) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  13. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  14. Initial blood lactate correlates with carboxyhemoglobin and clinical severity in carbon monoxide poisoned patients.

    Science.gov (United States)

    Cervellin, Gianfranco; Comelli, Ivan; Rastelli, Gianni; Picanza, Alessandra; Lippi, Giuseppe

    2014-12-01

    The aim of this study was to assess the role of blood lactate levels at admission in carbon monoxide (CO)-poisoned patients for establishing severity of poisoning and short term prognosis. All cases of CO poisoning visited in the emergency department during the years 2012 and 2013 were retrieved from the hospital database. The concentration of COHb and lactate was assessed in arterial blood in all patients with suspected CO poisoning, along with the plasma concentration of troponin I (TnI). The control population for TnI results consisted in 125 blood donors. Twenty three (61%) out of 38 CO-poisoned patients underwent hyperbaric oxygen (HBO) treatment, and 10 (26%) were admitted to a hospital ward. A significant correlation was found between lactate and COHb (r=0.54; p99th percentile compared to 2% controls (p=0.003). The odds ratio for detectable TnI and TnI >99th percentile in CO-poisoned patients were 13.1 (p<0.001) and 7.6 (p=0.006), respectively. Initial blood lactate level may be useful for risk stratification of CO-poisoned patients, especially for predicting hospitalization. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Percent free prostate-specific antigen is effective to predict prostate biopsy outcome in Chinese men with prostate-specific antigen between 10.1 and 20.0 ng ml−1

    Science.gov (United States)

    Chen, Rui; Zhou, Li-Qun; Cai, Xiao-Bing; Xie, Li-Ping; Huang, Yi-Ran; He, Da-Lin; Gao, Xu; Xu, Chuan-Liang; Ding, Qiang; Wei, Qiang; Yin, Chang-Jun; Ren, Shan-Cheng; Wang, Fu-Bo; Tian, Ye; Sun, Zhong-Quan; Fu, Qiang; Ma, Lu-Lin; Zheng, Jun-Hua; Ye, Zhang-Qun; Ye, Ding-Wei; Xu, Dan-Feng; Hou, Jian-Quan; Xu, Ke-Xin; Yuan, Jian-Lin; Gao, Xin; Liu, Chun-Xiao; Pan, Tie-Jun; Sun, Ying-Hao

    2015-01-01

    Percent free prostatic-specific antigen (%fPSA) has been introduced as a tool to avoid unnecessary biopsies in patients with a serum PSA level of 4.0–10.0 ng ml−1, however, it remains controversial whether %fPSA is effective in PSA range of 10.1–20.0 ng ml−1 in both Chinese and Western population. In this study, the diagnostic performance of %fPSA and serum PSA in predicting prostate cancer (PCa) and high-grade PCa (HGPCa) was analyzed in a multi-center biopsy cohort of 5915 consecutive Chinese patients who underwent prostate biopsy in 22 hospitals across China from January 1, 2010 to December 31, 2013. The indication for biopsy was PSA>4.0 ng ml−1 or/and suspicious digital rectal examination. Total and free serum PSA determinations were performed by three types of electrochemiluminescence immunoassays with recalibration to the World Health Organization standards. The diagnostics accuracy of PSA, %fPSA and %fPSA in combination with PSA (%fPSA + PSA) was determined by the area under the receivers operating characteristic curve (AUC). %fPSA was more effective than PSA in men aged ≥60 years old. The AUC was 0.584 and 0.635 in men aged ≥60 years old with a PSA of 4.0–10.0 ng ml−1 and 10.1–20.0 ng ml−1, respectively. The AUC of %fPSA was superior to that of PSA in predicting HGPCa in patients ≥60 years old in these two PSA range. Our results indicated that %fPSA is both statistically effective and clinical applicable to predict prostate biopsy outcome in Chinese patients aged ≥60 years old with a PSA of 4.0–10.0 ng ml−1 and 10.1–20.0 ng ml−1. PMID:25926603

  16. Percent free prostate-specific antigen is effective to predict prostate biopsy outcome in Chinese men with prostate-specific antigen between 10.1 and 20.0 ng ml(-1).

    Science.gov (United States)

    Chen, Rui; Zhou, Li-Qun; Cai, Xiao-Bing; Xie, Li-Ping; Huang, Yi-Ran; He, Da-Lin; Gao, Xu; Xu, Chuan-Liang; Ding, Qiang; Wei, Qiang; Yin, Chang-Jun; Ren, Shan-Cheng; Wang, Fu-Bo; Tian, Ye; Sun, Zhong-Quan; Fu, Qiang; Ma, Lu-Lin; Zheng, Jun-Hua; Ye, Zhang-Qun; Ye, Ding-Wei; Xu, Dan-Feng; Hou, Jian-Quan; Xu, Ke-Xin; Yuan, Jian-Lin; Gao, Xin; Liu, Chun-Xiao; Pan, Tie-Jun; Sun, Ying-Hao

    2015-01-01

    Percent free prostatic-specific antigen (%fPSA) has been introduced as a tool to avoid unnecessary biopsies in patients with a serum PSA level of 4.0-10.0 ng ml-1 , however, it remains controversial whether %fPSA is effective in PSA range of 10.1-20.0 ng ml-1 in both Chinese and Western population. In this study, the diagnostic performance of %fPSA and serum PSA in predicting prostate cancer (PCa) and high-grade PCa (HGPCa) was analyzed in a multi-center biopsy cohort of 5915 consecutive Chinese patients who underwent prostate biopsy in 22 hospitals across China from January 1, 2010 to December 31, 2013. The indication for biopsy was PSA>4.0 ng ml-1 or/and suspicious digital rectal examination. Total and free serum PSA determinations were performed by three types of electrochemiluminescence immunoassays with recalibration to the World Health Organization standards. The diagnostics accuracy of PSA, %fPSA and %fPSA in combination with PSA (%fPSA + PSA) was determined by the area under the receivers operating characteristic curve (AUC). %fPSA was more effective than PSA in men aged ≥60 years old. The AUC was 0.584 and 0.635 in men aged ≥60 years old with a PSA of 4.0-10.0 ng ml-1 and 10.1-20.0 ng ml-1 , respectively. The AUC of %fPSA was superior to that of PSA in predicting HGPCa in patients ≥60 years old in these two PSA range. Our results indicated that %fPSA is both statistically effective and clinical applicable to predict prostate biopsy outcome in Chinese patients aged ≥60 years old with a PSA of 4.0-10.0 ng ml-1 and 10.1-20.0 ng ml-1 .

  17. Selective and efficient reduction of carbon dioxide to carbon monoxide on oxide-derived nanostructured silver electrocatalysts

    NARCIS (Netherlands)

    Ma, Ming; Trześniewski, Bartek J.; Xie, Jie; Smith, Wilson A.

    2016-01-01

    In this work, the selective electrocatalytic reduction of carbon dioxide to carbon monoxide on oxide-derived silver electrocatalysts is presented. By a simple synthesis technique, the overall high faradaic efficiency for CO production on the oxide-derived Ag was shifted by more than 400 mV towards a

  18. Toxicity of carbon monoxide hydrogen cyanide gas mixtures : exposure concentration, time to incapacitation, carboxyhemoglobin and blood cyanide parameters.

    Science.gov (United States)

    1994-04-01

    During aircraft interior fires, carbon monoxide (CO) and hydrogen cyanide (HCN) are produced in sufficient amounts to cause incapacitation and death. Time-to-incapacitation (ti) is a practical parameter for estimating escape time in fire environments...

  19. Carbon monoxide and coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Scheidemandel, V

    1974-01-01

    Studies on the relationship between increased carboxyhemoglobin levels in the blood and coronary heart disease in smokers and city dwellers are reviewed. The evidence of myocardial infarction is significantly higher in smokers than in nonsmokers which is due, apart from nicotine which promotes coronary arteriosclerosis, to inhaled carbon monoxide which leads to increased carboxyhemoglobin levels and most likely plays a role in the risk of arteriosclerosis and the coronary heart disease. Apart from combining with hemoglobin, CO increases the circulation rate and the coronary blood flow, and reduces the coronary arteriovenous oxygen difference, which is indicative of a reduced rate of oxygen extraction by the myocardium against an increased myocardial oxygen demand. The reduction of the oxygen extraction correlates with the increased COHb level. Inhaled CO lowers the threshold of angina pectoris due to the reduced myocardial oxygen tension. Also, considerable reduction of the oxygen diffusion from the capillaries toward the mitochondria due to the combination of CO with myoglobin is observed. Chronically increased CO levels in the blood and tissues not only accelerate the development of arteriosclerosis, but also induce a process directly injurious to the myocardial metabolism. (Air Pollut. Abstr.)

  20. Carbon Monoxide: An Essential Signalling Molecule

    Science.gov (United States)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  1. Regional and hemispheric influences on temporal variability in baseline carbon monoxide and ozone over the Northeast US

    Science.gov (United States)

    Interannual variability in baseline carbon monoxide (CO) and ozone (O3), defined as mixing ratios under minimal influence of recent and local emissions, was studied for seven rural sites in the Northeast US over 2001–2010. Annual baseline CO exhibited statistically signific...

  2. Satellite observations of tropospheric ammonia and carbon monoxide: Global distributions, regional correlations and comparisons to model simulations

    Science.gov (United States)

    Ammonia (NH3) and carbon monoxide (CO) are primary pollutants emitted to the Earth's atmosphere from common as well as distinct sources associated with anthropogenic and natural activities. The seasonal and global distributions and correlations of NH3 and CO from the Tropospheric...

  3. Atomic hydrogen and diatomic titanium-monoxide molecular spectroscopy in laser-induced plasma

    Science.gov (United States)

    Parigger, Christian G.; Woods, Alexander C.

    2017-03-01

    This article gives a brief review of experimental studies of hydrogen Balmer series emission spectra. Ongoing research aims to evaluate early plasma evolution following optical breakdown in laboratory air. Of interest is as well laser ablation of metallic titanium and characterization of plasma evolution. Emission of titanium monoxide is discussed together with modeling of diatomic spectra to infer temperature. The behavior of titanium particles in plasma draws research interests ranging from the modeling of stellar atmospheres to the enhancement of thin film production via pulsed laser deposition.

  4. Zatrucie tlenkiem węgla – drogi narażenia, obraz kliniczny, metody leczenia = Carbon monoxide poisoning, routes of exposure, clinical manifestation, treatment

    Directory of Open Access Journals (Sweden)

    Magdalena Sowa

    2015-04-01

    owa kluczowe: tlenek węgla, zatrucie, hipoksja.   Abstract   Introduction: Carbon monoxide (CO is a colorless, odorless, non-irritating and toxic gas, undetectable by the sense organs. CO is a product of incomplete combustion of substances containing hydrocarbon products (industrial gas, coal, wood. Carbon monoxide is one of the most common causes of poisoning inhalation in the world. Aim of the study: The aim of this study was to analyze the routes of exposure, clinical manifestation and treatment of carbon monoxide poisoning. Brief overview of the state of knowledge: The toxicity of carbon monoxide is strongly associated with its high affinity for hemoglobin (approximately 200 times greater than the oxygen. The heart and central nervous system (CNS are the most vulnerable to CO. Pathomechanism of action involves binding of carbon monoxide with iron atom in the heme molecule to form a compound called carboxyhemoglobin (COHb. Inhaling carbon monoxide-rich air may cause anoxia. The oxidative metabolic processes are inhibited. Accumulation of acidic metabolites cause the enlargement of the cerebral arteries and consequently hyperemia of the brain. Summary: The amount of carbon monoxide poisoning in Poland is higher than in other European countries. Significant decrease mortality for carbon monoxide poisoning has observed over the last few years. Thousands of patients who lose their health and  their lives, should cause the attention to the effectiveness of preventive measures.   Keywords: carbon monoxide, poisoning, hypoxia.

  5. Phased Acoustic Array Measurements of a 5.75 Percent Hybrid Wing Body Aircraft

    Science.gov (United States)

    Burnside, Nathan J.; Horne, William C.; Elmer, Kevin R.; Cheng, Rui; Brusniak, Leon

    2016-01-01

    Detailed acoustic measurements of the noise from the leading-edge Krueger flap of a 5.75 percent Hybrid Wing Body (HWB) aircraft model were recently acquired with a traversing phased microphone array in the AEDC NFAC (Arnold Engineering Development Complex, National Full Scale Aerodynamics Complex) 40- by 80-Foot Wind Tunnel at NASA Ames Research Center. The spatial resolution of the array was sufficient to distinguish between individual support brackets over the full-scale frequency range of 100 to 2875 Hertz. For conditions representative of landing and take-off configuration, the noise from the brackets dominated other sources near the leading edge. Inclusion of flight-like brackets for select conditions highlights the importance of including the correct number of leading-edge high-lift device brackets with sufficient scale and fidelity. These measurements will support the development of new predictive models.

  6. Metal cluster cation reactions: Carbon monoxide association to Cu + n ions

    Science.gov (United States)

    Leuchtner, R. E.; Harms, A. C.; Castleman, A. W., Jr.

    1990-06-01

    Copper cluster cations (Cu+n,n=1-14) were produced in a laser vaporization/flow tube apparatus and equilibrated to room temperature. The association rate constants of carbon monoxide onto these ions were measured; low-pressure, termolecular behavior was observed for the smaller species while for clusters greater than Cu+7, the longer lifetimes due to the increased number of degrees of freedom leads to pressure independence (>0.3 Torr) of the effective bimolecular rates. Unimolecular decay theory (RRKM) is used to explain the overall trend and when intrinsic surface site reactivity is taken into account, excellent agreement with measured reactivity is obtained.

  7. Is there any chlorine monoxide in the stratosphere?

    Science.gov (United States)

    Mumma, M. J.; Rogers, J. D.; Kostiuk, T.; Deming, D.; Hillman, J. J.; Zipoy, D.

    1983-01-01

    A ground-based search for stratospheric 35-ClO was carried out using an infrared heterodyne spectrometer in the solar absorption mode. Lines due to stratospheric HNO3 and tropospheric OCS were detected at about 0.2 percent absorptance levels, but the expected 0.1 percent lines of ClO in this same region were not seen. We find that stratospheric ClO is at least a factor of seven less abundant than is indicated by in situ measurements, and we set an upper limit of 2.3 x 10 to the 13th molecules/sq cm at the 95 percent confidence level for the integrated vertical column density of ClO. Our results imply that the release of chlorofluorocarbons may be significantly less important for the destruction of stratospheric ozone (O3) than is currently thought. Previously announced in STAR as N83-27518

  8. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  9. Experience with high percent step load decrease from full power in NPP Krsko

    International Nuclear Information System (INIS)

    Vukovic, V.

    2000-01-01

    The control system of NPP Kriko, is designed to automatically control the reactor in the power range between 15 and 100 percent of rated power for the following designed transients; - 10 percent step change in load; 5 percent per minute loading and unloading; step full load decrease with the aid of automatically initiated and controlled steam dump. Because station operation below 15 percent of rated power is designed for a period of time during startup or standby conditions, automatic control below 15 percent is not provided. The steam dump accomplishes the following functional tasks: it permits the nuclear plants to accept a sudden 95 percent loss of load without incurring reactor trip; it removes stored energy and residual heat following a reactor trip and brings the plant to equilibrium no-load conditions without actuation of the steam generator safety valves; it permits control of the steam generator pressure at no-load conditions and permits a manually controlled cooldown of the plant. The first two functional tasks are controlled by Tavg. The third is controlled by steam pressure. Interlocks minimise any possibility of an inadvertent actuation of steam dump system. This paper discusses relationships between designed (described) characteristics of plant and the data which are obtained during startup and/or first ten years of operation. (author)

  10. Lethal carbon monoxide toxicity in a concrete shower unit.

    Science.gov (United States)

    Heath, Karen; Byard, Roger W

    2018-05-23

    A 47-year-old previously-well woman was found dead on the floor of a shower cubicle on a property in rural South Australia. The impression of the attending doctor and police was of collapse due to natural disease. Although there was significant stenosing coronary artery atherosclerosis found at autopsy, cherry pink discoloration of tissues prompted measurement of the blood carboxyhemoglobin level which was found to be 55%. The source of the gas was a poorly-maintained hot water heater that was mounted on the inside wall of the shower. Construction of the shower using an impermeable concrete rain water tank had caused gas accumulation when the water heater malfunctioned. Had lethal carbon monoxide exposure not been identified others using the same shower unit would also have been at risk.

  11. Predicting Variations in Math Performancein Four Countries Using TIMSS

    Directory of Open Access Journals (Sweden)

    Daniel Koretz

    2001-09-01

    Full Text Available Although international comparisons of average student performance are a staple of U.S. educational debate, little attention has been paid to cross-national differences in the variability of performance. It is often assumed that the performance of U.S. students is unusually variable or that the distribution of U.S. scores is left-skewed – that is, that it has an unusually long ‘tail' of low-scoring students – but data from international studies are rarely brought to bear on these questions. This study used data from the Third International Mathematics and Science Study (TIMSS to compare the variability of performance in the U.S., Australia, France, Germany, Hong Kong, Korea, and Japan; investigate how this performance variation is distributed within and between classrooms; and explore how well background variables predict performance at both levels. TIMSS shows that the U.S. is not anomalous in terms of the amount, distribution, or prediction of performance variation. Nonetheless, some striking differences appear between countries that are potentially important for both research and policy. In the U.S., Germany, Hong Kong, and Australia, between 42 and 47 percent of score variance was between classrooms. At the other extreme, Japan and Korea both had less than 10 percent of score variance between classrooms. Two-level models (student and classroom were used to explore the prediction of performance by social background variables in four of these countries (the U.S., Hong Kong, France, and Korea. The final models included only a few variables; TIMSS lacked some important background variables, such as income, and other variables were dropped either because of problems revealed by exploratory data analysis or because of a lack of significance in the models. In all four countries, these sparse models predicted most of the between-classroom score variance (from 59 to 94 percent but very little of the within-classroom variance. Korea was the only

  12. School Designed To Use 80 Percent Less Energy

    Science.gov (United States)

    American School and University, 1975

    1975-01-01

    The new Terraset Elementary School in Reston, Virginia, uses earth as a cover for the roof area and for about 80 percent of the wall area. A heat recovery system will be used with solar collectors playing a primary role in heating and cooling. (Author/MLF)

  13. A Deep Learning Network Approach to ab initio Protein Secondary Structure Prediction.

    Science.gov (United States)

    Spencer, Matt; Eickholt, Jesse; Jianlin Cheng

    2015-01-01

    Ab initio protein secondary structure (SS) predictions are utilized to generate tertiary structure predictions, which are increasingly demanded due to the rapid discovery of proteins. Although recent developments have slightly exceeded previous methods of SS prediction, accuracy has stagnated around 80 percent and many wonder if prediction cannot be advanced beyond this ceiling. Disciplines that have traditionally employed neural networks are experimenting with novel deep learning techniques in attempts to stimulate progress. Since neural networks have historically played an important role in SS prediction, we wanted to determine whether deep learning could contribute to the advancement of this field as well. We developed an SS predictor that makes use of the position-specific scoring matrix generated by PSI-BLAST and deep learning network architectures, which we call DNSS. Graphical processing units and CUDA software optimize the deep network architecture and efficiently train the deep networks. Optimal parameters for the training process were determined, and a workflow comprising three separately trained deep networks was constructed in order to make refined predictions. This deep learning network approach was used to predict SS for a fully independent test dataset of 198 proteins, achieving a Q3 accuracy of 80.7 percent and a Sov accuracy of 74.2 percent.

  14. Vibration response imaging in idiopathic pulmonary fibrosis: a pilot study.

    Science.gov (United States)

    Liu, Qing-Xia; Guan, Wei-Jie; Xie, Yan-Qing; An, Jia-Ying; Jiang, Mei; Zhu, Zheng; Guo, E; Yu, Xin-Xin; Liu, Wen-Ting; Gao, Yi; Zheng, Jin-Ping

    2014-07-01

    Vibration response imaging (VRI) is a novel imaging technique and little is known about its characteristics and diagnostic value in idiopathic pulmonary fibrosis (IPF). The aim of this study was to investigate the features of VRI in subjects with IPF. We enrolled 23 subjects with IPF (42-74 y old) and 28 healthy subjects (42-72 y old). Subjects with IPF were diagnosed by lung biopsy and underwent VRI, spirometry, lung diffusion testing, and chest x-ray or computed tomography, which entailed assessment of the value of VRI indices. The total VRI score correlated statistically with single-breath carbon monoxide diffusing capacity percent predicted (r = -0.30, P = .04), but not with FVC percent predicted, FEV1 percent predicted, and FEV1/FVC (r = -0.27, -0.22, and 0.19; all P > .05). Compared with healthy subjects (17.9%), 20 subjects with IPF (86.96%, P .05), except for the upper right and lower left lobes (P diagnostic value (sensitivity, 1.00; specificity, 0.82), followed by presence of abundant crackles (sensitivity, 0.70; specificity, 0.96). Total VRI score was not a sensitive indicator of IPF, owing to low assay sensitivity (0.70) and specificity (0.64). VRI may be helpful to discriminate between IPF subjects and healthy individuals. Maximum energy frame and abundant crackles might serve as a diagnostic tool for IPF. Copyright © 2014 by Daedalus Enterprises.

  15. A PREDICTIVE STUDY: CARBON MONOXIDE EMISSION MODELING AT A SIGNALIZED INTERSECTION

    Directory of Open Access Journals (Sweden)

    FREDDY WEE LIANG KHO

    2014-02-01

    Full Text Available CAL3QHC dispersion model was used to predict the present and future carbonmonoxide (CO levels at a busy signalized intersection. This study attempted to identify CO “hot-spots” at nearby areas of the intersection during typical A.M. and P.M. peak hours. The CO concentration “hot-spots” had been identified at 101 Commercial Park and the simulated maximum 1-hour Time-Weighted Average (1-h TWA ground level CO concentrations of 18.3 ppm and 18.6 ppm had been observed during A.M. and P.M. peaks, respectively in year 2006. This study shows that there would be no significant increment in CO level for year 2014 although a substantial increase in the number of vehicles is assumed to affect CO levels. It was also found that CO levels would be well below the Malaysian Ambient Air Quality Guideline of 30 ppm (1-h TWA. Comparisons between the measured and simulated CO levels using quantitative data analysis technique and statistical methods indicated that CAL3QHC dispersion model correlated well with measured data.

  16. National Land Cover Database (NLCD) Percent Developed Imperviousness Collection

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The National Land Cover Database (NLCD) Percent Developed Imperviousness Collection is produced through a cooperative project conducted by the Multi-Resolution Land...

  17. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  18. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    Science.gov (United States)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Etherton, B.P.

    1980-01-01

    The adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts which were examined by a scanning transmission electron microscope (STEM). The metal particle size and number of particles per area of catalyst increased with increasing metal loading. The particles were approx. 10 A. in diameter, cubo-octahedral shaped, and approx. 80-90% disperse. The STEM electron beam caused negligible damage to the samples. Hydrogen adsorption measurements showed that the hydrogen-iridium atom ratio was 1.2:1-1.3:1 and increased with decreasing metal loading. Temperature-programed desorption showed four types of adsorbed hydrogen desorbing at -90/sup 0/C (I), 15/sup 0/C (IV), 115/sup 0/C (II), and 245/sup 0/C (III). Types II and IV desorb from single atom sites and Types I and III from multiple atom sites. Type I is in rapid equilibrium with the gas phase. All desorption processes appear to be first order. Carbon monoxide adsorbed nondissociatively at 25/sup 0/C with approx. 0.7:1 CO/Ir atom ratio. It adsorbed primarily in linear forms at low coverage, but a bridged form appeared at high coverage.

  20. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    Science.gov (United States)

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  1. Electrocardiographic Findings and Serum Troponin I in Carbon Monoxide Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Scott Reza Jafarian Kerman

    2012-03-01

    Full Text Available Carbon monoxide (CO poisoning, though with different sources, is one of the most deadly emergencies in all countries. CO can threaten men's life by several paths especially cardiac complications, which can mimic other cardiac problems such as myocardial infarction. The objective of this study was to determine ECG findings and serum troponin I levels in CO poisoned patients. In this analytical cross-sectional study, 63 CO poisoning patients were consecutively included from hospital's emergency departments. CO content was measured by a CO-oximeter and an electrocardiography was taken first thing on admission. Arterial blood gas (ABG, troponin I and other data was collected afterwards. Data were divided by age groups (adults and children and gender. CO content was significantly higher only in subjects with normal T wave compared to patients with inverted T wave in their initial ECG (P=0.016. No other significant difference was noticed. None of the ABG findings correlated significantly with CO content. Also no significant correlation was found with CO content after stratification by gender and age groups, but pH in children (r=-0.484, P=0.026. CO content was significantly higher in adults (P=0.023, but other ABG data were not significantly different. Only 3 patients had elevated troponin I. Receiver operating characteristic (ROC analysis showed no significant cutoff points in CO content for ECG changes. No significant specific change in electrocardiograms (ECG could contribute carboxyhemoglobin content in carbon monoxide poisoned patients. In addition, no specific difference was found between adults and pediatric subjects' ECGs. All other findings seemed to be accidental.

  2. Running speed during training and percent body fat predict race time in recreational male marathoners

    OpenAIRE

    Knechtle, Beat; Barandun,; Knechtle,Patrizia; Klipstein,; Rüst,Christoph Alexander; Rosemann,Thomas; Lepers,Romuald

    2012-01-01

     Background: Recent studies have shown that personal best marathon time is a strong predictor of race time in male ultramarathoners. We aimed to determine variables predictive of marathon race time in recreational male marathoners by using the same characteristics of anthropometry and training as used for ultramarathoners.Methods: Anthropometric and training characteristics of 126 recreational male marathoners were bivariately and multivariately related to marathon race times.Results...

  3. Development of CuxFe/Al2O3 catalysts for the hydrogenation of carbon monoxide guided by magnetic methods, Moessbauer and infrared spectroscopy

    International Nuclear Information System (INIS)

    Boellaard, E.; Geus, J.W.; Bruggen, J.M. van; Kraan, A.M. van der

    1993-01-01

    A copper-iron catalyst for the hydrogenation of carbon monoxide has been prepared using a supported stoichiometric cyanide complex. Conversion of the cyanide precursor to a metallic catalyst appeared to be a precious process. Copper and iron in the bimetallic particles easily separate by thermal treatment and upon exposure to carbon monoxide, as revealed from Moessbauer and infrared spectroscopy. During Fischer-Tropsch reaction the catalyst exhibits a rapid decline of activity. Magnetisation measurements on spent catalysts indicate that the deactivation is caused by a fast conversion of metallic iron to initially unstable carbides which transform ultimately to more stable carbides. (orig.)

  4. Predicting Tissue-Specific Enhancers in the Human Genome

    Energy Technology Data Exchange (ETDEWEB)

    Pennacchio, Len A.; Loots, Gabriela G.; Nobrega, Marcelo A.; Ovcharenko, Ivan

    2006-07-01

    Determining how transcriptional regulatory signals areencoded in vertebrate genomes is essential for understanding the originsof multi-cellular complexity; yet the genetic code of vertebrate generegulation remains poorly understood. In an attempt to elucidate thiscode, we synergistically combined genome-wide gene expression profiling,vertebrate genome comparisons, and transcription factor binding siteanalysis to define sequence signatures characteristic of candidatetissue-specific enhancers in the human genome. We applied this strategyto microarray-based gene expression profiles from 79 human tissues andidentified 7,187 candidate enhancers that defined their flanking geneexpression, the majority of which were located outside of knownpromoters. We cross-validated this method for its ability to de novopredict tissue-specific gene expression and confirmed its reliability in57 of the 79 available human tissues, with an average precision inenhancer recognition ranging from 32 percent to 63 percent, and asensitivity of 47 percent. We used the sequence signatures identified bythis approach to assign tissue-specific predictions to ~;328,000human-mouse conserved noncoding elements in the human genome. Byoverlapping these genome-wide predictions with a large in vivo dataset ofenhancers validated in transgenic mice, we confirmed our results with a28 percent sensitivity and 50 percent precision. These results indicatethe power of combining complementary genomic datasets as an initialcomputational foray into the global view of tissue-specific generegulation in vertebrates.

  5. On the feasibility of monitoring carbon monoxide in the lower troposphere from a constellation of Northern Hemisphere geostationary satellites. (Part 1)

    Science.gov (United States)

    Barré, Jérôme; Edwards, David; Worden, Helen; Da Silva, Arlindo; Lahoz, William

    2015-07-01

    By the end of the current decade, there are plans to deploy several geostationary Earth orbit (GEO) satellite missions for atmospheric composition over North America, East Asia and Europe with additional missions proposed. Together, these present the possibility of a constellation of geostationary platforms to achieve continuous time-resolved high-density observations over continental domains for mapping pollutant sources and variability at diurnal and local scales. In this paper, we use a novel approach to sample a very high global resolution model (GEOS-5 at 7 km horizontal resolution) to produce a dataset of synthetic carbon monoxide pollution observations representative of those potentially obtainable from a GEO satellite constellation with predicted measurement sensitivities based on current remote sensing capabilities. Part 1 of this study focuses on the production of simulated synthetic measurements for air quality OSSEs (Observing System Simulation Experiments). We simulate carbon monoxide nadir retrievals using a technique that provides realistic measurements with very low computational cost. We discuss the sampling methodology: the projection of footprints and areas of regard for geostationary geometries over each of the North America, East Asia and Europe regions; the regression method to simulate measurement sensitivity; and the measurement error simulation. A detailed analysis of the simulated observation sensitivity is performed, and limitations of the method are discussed. We also describe impacts from clouds, showing that the efficiency of an instrument making atmospheric composition measurements on a geostationary platform is dependent on the dominant weather regime over a given region and the pixel size resolution. These results demonstrate the viability of the ;instrument simulator; step for an OSSE to assess the performance of a constellation of geostationary satellites for air quality measurements. We describe the OSSE results in a follow up

  6. Carbon Monoxide Hydrogenation on Ice Surfaces.

    Science.gov (United States)

    Kuwahata, Kazuaki; Ohno, Kaoru

    2018-03-14

    We have performed density functional calculations to investigate the carbon monoxide hydrogenation reaction (H+CO→HCO), which is important in interstellar clouds. We found that the activation energy of the reaction on amorphous ice is lower than that on crystalline ice. In the course of this study, we demonstrated that it is roughly possible to use the excitation energy of the reactant molecule (CO) in place of the activation energy. This relationship holds also for small water clusters at the CCSD level of calculation and the two-layer-level ONIOM (CCSD : X3LYP) calculation. Generally, since it is computationally demanding to estimate activation energies of chemical reactions in a circumstance of many water molecules, this relationship enables one to determine the activation energy of this reaction on ice surfaces from the knowledge of the excitation energy of CO only. Incorporating quantum-tunneling effects, we discuss the reaction rate on ice surfaces. Our estimate that the reaction rate on amorphous ice is almost twice as large as that on crystalline ice is qualitatively consistent with the experimental evidence reported by Hidaka et al. [Chem. Phys. Lett., 2008, 456, 36.]. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Influence of solvent on the infared spectrum of carbon monoxide adsorbed on platinum electrodes

    OpenAIRE

    Feltovich, Susanne D.

    1993-01-01

    The behavior of adsorbed carbon monoxide on platinum was studied using potential difference infrared spectroscopy. Three solvents and three electrolytes were chosen, and data gathered at both high and low adsorbate coverages. The rate of change of IR peak position with applied potential, the Stark tuning rate, was used as an indicator of the local electric field strength at the interface. It was determined that neither solvated cation size nor bulk dielectric constant accoun...

  8. Subclinical carbon monoxide poisoning in our health area

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, I.G.; Testa, A.F.; Sangrador, C.O.; Garcia, M.T.A.; Berrocal, J.L.S.; Pastor, N.R.; Martin, J.M.; Garcia, L.S.; Garcia, M.C.F.; Maire-Richard, E.G. [Hospital of Virgen Concha, Zamora (Spain)

    2003-08-01

    We present an observation study on the relationship between high levels of carboxyhemoglobin (COHB) and subclinical poisoning by carbon monoxide (CO) in our health area. The study was carried out in February and March 2000 in 228 over 18-year-old patients of both sexes who went to the Emergency Room for various reasons. After an informed consent was conceded, a venous blood sample was obtained in order to determine the level of COHB; later, we collected the anthropometric data, the data relative to the tobacco use, and the data of the type of heating at home. The values limit of the COHB obtained were the following: in non smokers, 1.9%; in 1-10 cigarettes/day smokers, 5.2%; in 11-20 cigarettes/day smokers, 6.9%; in {gt}20 cigarettes/day smokers, 9.6%. A COHB high level was observed in 25% of the patients regardless of the smoking habits, being the coal-dust slack brazier the source of most frequent exposure to CO.

  9. Detection of the J = 6→5 transition of carbon monoxide

    International Nuclear Information System (INIS)

    Goldsmith, P.F.; Erickson, N.R.; Fetterman, H.R.; Clifton, B.J.; Peck, D.D.; Tannenwald, P.E.; Koepf, G.A.; Buhl, D.; McAvoy, N.

    1981-01-01

    The J = 6→5 rotational transition of carbon monoxide has been detected in emission from the KL ''plateau source'' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km s -1 . These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. Our data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approx.180 K

  10. Study on radiation degradation of hydroxylamine derivatives. Pt.3: Qualitative and quantitative analyses of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine

    International Nuclear Information System (INIS)

    Wang Jinhua; Bao Borong; Wu Minghong; Sun Xilian

    2004-01-01

    The qualitative and quantitative analysis of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine is performed on a 2 m column packed with 5 Angstrom molecular sieve and equipped with a thermal conductivity detector. The analysis of hydrogen employs argon as a carrier gas, the column temperature is 85 degree C and the detector temperature is 110 degree C; the analysis of carbon monoxide employs hydrogen as a carrier gas, the column temperature is 50 degree C and the detector temperature is 80 degree C. The results show that the volume fraction of hydrogen is increased with the increase of dose, but has little relationship with the concentration of N,N-diethyl hydroxylamine. Carbon monoxide is only produced when the absorption dose is very high and the volume fraction is very low

  11. Exhaled carbon monoxide: a non-invasive biomarker of short-term exposure to outdoor air pollution

    Directory of Open Access Journals (Sweden)

    Herve Lawin

    2017-04-01

    Full Text Available Abstract Background In urban settings of Africa with rapidly increasing population, traffic-related air pollution is a major contributor to outdoor air pollution (OAP. Although OAP has been identified as a leading cause of global morbidity and mortality, there is however, lack of a simple biomarker to assess levels of exposure to OAP in resource-poor settings. This study evaluated the role of exhaled carbon monoxide (exhCO as a potential biomarker of exposure to ambient carbon monoxide (ambCO from OAP. Methods This was a descriptive study conducted among male commercial motorcycle riders in Cotonou – the economic capital of Benin. The participants’ AmbCO was measured using a portable carbon monoxide (CO data logger for 8 h during the period of their shift. ExhCO was measured just before and immediately after their shift (8-h Participants were asked not to cook or to smoke during the day of the measurements. Linear regression analysis was used to assess the association between ambCO and exhCO for the last 2, 4 and 6 h of their shift. Results Of 170 participants who completed the study, their mean ± SD age was 42.2 ± 8.4 years, and their mean ± SD daily income was 7.3 ± 2.7$. Also, 95% of the participants’ used solid fuels for cooking and only 2% had ever smoked. Average exhCO increased by 5.1 ppm at the end of the shift (p = 0.004. Post-shift exhCO was significantly associated to ambCO, this association was strongest for the last 2 h of OAP exposure before exhCO measurement (β = 0.34, p < 0.001. Conclusion ExhCO level was associated with recent exposure to ambCO from OAP with measurable increase after 8 h of exposure. These findings suggest that ExhCO may be a potential biomarker of short-term exposure to OAP.

  12. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    Science.gov (United States)

    At some level, carboxyhemoglobin (RbCO) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in normal and ischemic heart patients. At high RbCO levels in normal subjects, brain function is also affected and behavioral performance is impaired. These are fin...

  13. Using built environment characteristics to predict walking for exercise

    Directory of Open Access Journals (Sweden)

    Siscovick David S

    2008-02-01

    Full Text Available Abstract Background Environments conducive to walking may help people avoid sedentary lifestyles and associated diseases. Recent studies developed walkability models combining several built environment characteristics to optimally predict walking. Developing and testing such models with the same data could lead to overestimating one's ability to predict walking in an independent sample of the population. More accurate estimates of model fit can be obtained by splitting a single study population into training and validation sets (holdout approach or through developing and evaluating models in different populations. We used these two approaches to test whether built environment characteristics near the home predict walking for exercise. Study participants lived in western Washington State and were adult members of a health maintenance organization. The physical activity data used in this study were collected by telephone interview and were selected for their relevance to cardiovascular disease. In order to limit confounding by prior health conditions, the sample was restricted to participants in good self-reported health and without a documented history of cardiovascular disease. Results For 1,608 participants meeting the inclusion criteria, the mean age was 64 years, 90 percent were white, 37 percent had a college degree, and 62 percent of participants reported that they walked for exercise. Single built environment characteristics, such as residential density or connectivity, did not significantly predict walking for exercise. Regression models using multiple built environment characteristics to predict walking were not successful at predicting walking for exercise in an independent population sample. In the validation set, none of the logistic models had a C-statistic confidence interval excluding the null value of 0.5, and none of the linear models explained more than one percent of the variance in time spent walking for exercise. We did not

  14. Four deaths due to carbon monoxide poisoning in car washes.

    Science.gov (United States)

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  15. National Land Cover Database (NLCD) Percent Tree Canopy Collection

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The National Land Cover Database (NLCD) Percent Tree Canopy Collection is a product of the U.S. Forest Service (USFS), and is produced through a cooperative project...

  16. 1H MR spectroscopy of gray and white matter in carbon monoxide poisoning

    DEFF Research Database (Denmark)

    Kondziella, D.; Danielsen, E.R.; Hansen, K.

    2009-01-01

    Carbon monoxide (CO) intoxication leads to acute and chronic neurological deficits, but little is known about the specific noxious mechanisms. (1)H magnetic resonance spectroscopy (MRS) may allow insight into the pathophysiology of CO poisoning by monitoring neurochemical disturbances, yet only......, magnetic resonance imaging (MRI) and neuropsychological testing. Five patients suffered from acute high-dose CO intoxication and were in coma for 1-6 days. In these patients, MRI revealed hyperintensities of the white matter and globus pallidus and also showed increased choline (Cho) and decreased N...

  17. Unintentional carbon monoxide poisoning hospitalization and emergency department counts and rates by county, year, and fire-relatedness among California residents,2000-2007

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of unintentional carbon monoxide poisoning (CO) inpatient hospitalizations and emergency...

  18. Environmental pollution by automotive source. II. Local inhabitants's reaction to environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, R; Hirara, K; Izumi, T; Mori, S

    1975-04-01

    The reaction of inhabitants to auto exhaust, noise, and vibration was surveyed in commercial and residential quarters by inquiries and measurement of the carbon monoxide in expired air of the inhabitants. About 65 percent of the inhabitants of busy quarters complained of severe reactions to auto exhaust, noise, and vibration; physical effects included headache, absentmindedness, loss of appetite, prickling of eyes, pain in the throat, and frequent colds. The concentration of carbon monoxide in the expired air of inhabitants of residential quarters was about 5 ppM, and in the busy quarter with much motor traffic the concentration was about 10 ppM. The concentration of carboxyhemoglobin in blood of the latter averaged 2.5 to 2.6 percent, and the former was 1.5 percent. The data were taken among non-smokers, and there were socio-economic differences among inhabitants of both quarters.

  19. Environmental pollution by automotive source. II. Local inhabitants's reaction to environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, R.; Hirara, K.; Izumi, T.; Mori, S.

    1975-04-01

    The reaction of inhabitants to auto exhaust, noise, and vibration was surveyed in commercial and residential quarters by inquiries and measurement of the carbon monoxide in expired air of the inhabitants. About 65 percent of the inhabitants of busy quarters complained of severe reactions to auto exhaust, noise, and vibration; physical effects included headache, absentmindedness, loss of appetite, prickling of eyes, pain in the throat, and frequent colds. The concentration of carbon monoxide in the expired air of inhabitants of residential quarters was about 5 ppM, and in the busy quarter with much motor traffic the concentration was about 10 ppM. The concentration of carboxyhemoglobin in blood of the latter averaged 2.5 to 2.6 percent, and the former was 1.5 percent. The data were taken among non-smokers, and there were socio-economic differences among inhabitants of both quarters.

  20. Effects of carbonyl bond, metal cluster dissociation, and evaporation rates on predictions of nanotube production in high-pressure carbon monoxide

    Science.gov (United States)

    Scott, Carl D.; Smalley, Richard E.

    2003-01-01

    The high-pressure carbon monoxide (HiPco) process for producing single-wall carbon nanotubes (SWNTs) uses iron pentacarbonyl as the source of iron for catalyzing the Boudouard reaction. Attempts using nickel tetracarbonyl led to no production of SWNTs. This paper discusses simulations at a constant condition of 1300 K and 30 atm in which the chemical rate equations are solved for different reaction schemes. A lumped cluster model is developed to limit the number of species in the models, yet it includes fairly large clusters. Reaction rate coefficients in these schemes are based on bond energies of iron and nickel species and on estimates of chemical rates for formation of SWNTs. SWNT growth is measured by the conformation of CO2. It is shown that the production of CO2 is significantly greater for FeCO because of its lower bond energy as compared with that of NiCO. It is also shown that the dissociation and evaporation rates of atoms from small metal clusters have a significant effect on CO2 production. A high rate of evaporation leads to a smaller number of metal clusters available to catalyze the Boudouard reaction. This suggests that if CO reacts with metal clusters and removes atoms from them by forming MeCO, this has the effect of enhancing the evaporation rate and reducing SWNT production. The study also investigates some other reactions in the model that have a less dramatic influence.

  1. Investigation of four carbon monoxide isotopomers in natural abundance by laser-induced fluorescence in a supersonic jet

    CSIR Research Space (South Africa)

    Du Plessis, A

    2007-01-01

    Full Text Available The four carbon monoxide (CO) isotopomers 12C16O, 13C16O, 12C18O and 12C17O have been detected simultaneously in a CO gas sample of natural isotopic abundance by measuring rovibronic excitation spectra of six vibronic bands in the Fourth Positive...

  2. Copolymerization of carbon monoxide and styrene catalyzed by resin-supported palladium polymer

    Directory of Open Access Journals (Sweden)

    2007-02-01

    Full Text Available Polyketone was prepared by the copolymerization of carbon monoxide (CO and styrene (ST catalyzed by o-phenylenediamine resin-supported palladium acetate. Effects of each catalytic system component such as 2,2’-bipyridine, 1,4-quinone and p-toluene-sulphonate on the copolymerization were investigated. The resin-supported catalyst and the copolymerization product were characterized by infrared spectroscopy (IR, differential scanning calorimetry (DSC, thermogravimetry (TG, X-ray photoelectron spectroscopy (XPS, Scanning Electron Microscopy (SEM. Results indicated that the resin-supported catalyst has excellent catalytic property. Furthermore, partial catalytic activity was maintained after the catalyst was used for five times.

  3. Exposure of commuters to carbon monoxide in Mexico City II. Comparison of in-vehicle and fixed-site concentrations.

    Science.gov (United States)

    Fernandez-Bremauntz, A A; Ashmore, M R

    1995-01-01

    The objective of this paper is to compare measurements of carbon monoxide taken concurrently inside vehicles and at fixed-site monitoring stations (FSMs), in order to assess if the FSM stations can be used to estimate commuters' exposure to this pollutant. During the study period ambient CO concentrations were very high. Five selected stations reported concentrations in excess of the Mexican (13 ppm) and United States (9 ppm) 8-hour standards for CO. Since, for all modes of transportation, the in-vehicle concentrations were always larger than the concurrent ambient concentrations, the differences between them were always positive and the ratios were always greater than one. Average, in-vehicle/ambient ratios for each mode of transportation were: automobile, 5.2; minivan, 5.2; minibus, 4.3; bus, 3.1; trolleybus 3.0; and metro, 2.2. A series of simple regression models with a moderate predictive power (R2 = 0.47 to 0.71) were developed for metro, bus, minibus, and automobile commuters. The models include the FSM measurements and also, depending on the mode of transportation, other variables, such as vehicular speed, the route of travel, and the wind speed. In the future, the models should be validated in two ways to determine their predictive power. First, they should be verified against additional samples taken under similar conditions; and second, their applications under different conditions should be explored through sampling during a different season of the year or on other commuting routes.

  4. Modeling percent tree canopy cover: a pilot study

    Science.gov (United States)

    John W. Coulston; Gretchen G. Moisen; Barry T. Wilson; Mark V. Finco; Warren B. Cohen; C. Kenneth Brewer

    2012-01-01

    Tree canopy cover is a fundamental component of the landscape, and the amount of cover influences fire behavior, air pollution mitigation, and carbon storage. As such, efforts to empirically model percent tree canopy cover across the United States are a critical area of research. The 2001 national-scale canopy cover modeling and mapping effort was completed in 2006,...

  5. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    Science.gov (United States)

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  6. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide 5 degree by 5 degree data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS OverviewThe MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights on...

  7. The BDGP gene disruption project: Single transposon insertions associated with 40 percent of Drosophila genes

    Energy Technology Data Exchange (ETDEWEB)

    Bellen, Hugo J.; Levis, Robert W.; Liao, Guochun; He, Yuchun; Carlson, Joseph W.; Tsang, Garson; Evans-Holm, Martha; Hiesinger, P. Robin; Schulze, Karen L.; Rubin, Gerald M.; Hoskins, Roger A.; Spradling, Allan C.

    2004-01-13

    The Berkeley Drosophila Genome Project (BDGP) strives to disrupt each Drosophila gene by the insertion of a single transposable element. As part of this effort, transposons in more than 30,000 fly strains were localized and analyzed relative to predicted Drosophila gene structures. Approximately 6,300 lines that maximize genomic coverage were selected to be sent to the Bloomington Stock Center for public distribution, bringing the size of the BDGP gene disruption collection to 7,140 lines. It now includes individual lines predicted to disrupt 5,362 of the 13,666 currently annotated Drosophila genes (39 percent). Other lines contain an insertion at least 2 kb from others in the collection and likely mutate additional incompletely annotated or uncharacterized genes and chromosomal regulatory elements. The remaining strains contain insertions likely to disrupt alternative gene promoters or to allow gene mis-expression. The expanded BDGP gene disruption collection provides a public resource that will facilitate the application of Drosophila genetics to diverse biological problems. Finally, the project reveals new insight into how transposons interact with a eukaryotic genome and helps define optimal strategies for using insertional mutagenesis as a genomic tool.

  8. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    International Nuclear Information System (INIS)

    Mu, Jiali; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-01-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl 2 catalyst and PdCl 2 catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl 2 catalyst) was more thermally stable than PK (PdCl 2 catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by 1 H NMR, 13 C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E k ) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E k values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol −1 . Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK

  9. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Jiali, E-mail: jiaqm411@163.com; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-03-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl{sub 2} catalyst and PdCl{sub 2} catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl{sub 2} catalyst) was more thermally stable than PK (PdCl{sub 2} catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by {sup 1}H NMR, {sup 13}C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E{sub k}) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E{sub k} values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol{sup −1}. Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK.

  10. CRED Cumulative Map of Percent Scleractinian Coral Cover at Sarigan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  11. CRED Cumulative Map of Percent Scleractinian Coral Cover at Saipan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  12. CRED Cumulative Map of Percent Scleractinian Coral Cover at Tutuila

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  13. CRED Cumulative Map of Percent Scleractinian Coral Cover at Anatahan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  14. CRED Cumulative Map of Percent Scleractinian Coral Cover at Alamagan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  15. CRED Cumulative Map of Percent Scleractinian Coral Cover at Agrihan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  16. CRED Cumulative Map of Percent Scleractinian Coral Cover at Pagan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  17. CRED Cumulative Map of Percent Scleractinian Coral Cover at Asuncion

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  18. CRED Cumulative Map of Percent Scleractinian Coral Cover at Aguijan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  19. Neurological Effects of Acute Carbon Monoxide Poisoning in Children

    Directory of Open Access Journals (Sweden)

    Coskun YARAR

    2009-11-01

    Full Text Available Carbon monoxide poisoning (COP is one of the most common causes of mortality and morbidity due to poisoning in all over the world. Although the incidence of COP has not been known exactly in the childhood, almost one-third of CO exposures occurred in children. The data regarding COP in children are inconclusive. Children may be more vulnerable to CO exposure than adults as a result of their high respiration and metabolic rates, high oxygen metabolism, and immature central nervous system. Recent researches proposed new theories about neurological effects of CO toxicity. The clinical presentations associated acute COP may be various and nonspecific. Unrecognized CO exposure may lead to significant morbidity and mortality. CO exposed children often become symptomatic earlier, and recover more rapidly, than similarly CO exposed adults. Mild clinical signs and symptoms associated with COP are headache, dizziness, weakness, lethargy, and myalgia; however, severe signs and symptoms such as blurred vision, syncope, convulsion, coma, cardiopulmonary arrest and death can also accompany with COP. Neurologic manifestations can include altered mental status at different degrees, neck stiffness, tremor, ataxia, and positive Babinski's sign. Delayed neurologic sequels (DNS of COP might be seen in children like adults. DNS symptoms and signs in children include memory problems, mental retardation, mutism, fecal and urinary incontinence, motor deficits, facial palsy, psychosis, chronic headache, seizures, and epilepsy. After CO exposure children must be cared to detect and treat DNS. Although hyperbaric oxygen therapy (HBOT is reported to prevent development of DNS, its indications, application duration and procedures are controversial in both of the children and adults. Although their predictive values are limited, exposing to CO more than eight hours and suffering from CO-induced coma, cardiac arrest, lactic acidosis, high COHb levels, and pathologic findings

  20. Completion of the first approach to critical for the seven percent critical experiment

    International Nuclear Information System (INIS)

    Barber, A. D.; Harms, G. A.

    2009-01-01

    The first approach-to-critical experiment in the Seven Percent Critical Experiment series was recently completed at Sandia. This experiment is part of the Seven Percent Critical Experiment which will provide new critical and reactor physics benchmarks for fuel enrichments greater than five weight percent. The inverse multiplication method was used to determine the state of the system during the course of the experiment. Using the inverse multiplication method, it was determined that the critical experiment went slightly supercritical with 1148 fuel elements in the fuel array. The experiment is described and the results of the experiment are presented. (authors)

  1. Carbon monoxide measurements at Mace Head, Ireland

    Science.gov (United States)

    Doddridge, Bruce G.; Dickerson, Russell R.; Spain, T. Gerard; Oltmans, Samuel J.; Novelli, Paul C.

    1994-01-01

    The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

  2. CO2 Reduction Catalyzed by Nitrogenase: Pathways to Formate, Carbon Monoxide, and Methane

    OpenAIRE

    Khadka, Nimesh; Dean, Dennis R.; Smith, Dayle; Hoffman, Brian M.; Raugei, Simone; Seefeldt, Lance C.

    2016-01-01

    The reduction of N2 to NH3 by Mo-dependent nitrogenase at its active-site metal cluster FeMo-cofactor utilizes reductive elimination (re) of Fe-bound hydrides with obligatory loss of H2 to activate the enzyme for binding/reduction of N2. Earlier work showed that wild type nitrogenase and a nitrogenase having amino acid substitutions in the MoFe protein near FeMo-cofactor can catalytically reduce CO2 by 2 or 8 electrons/protons to carbon monoxide (CO) and methane (CH4) at low rates. Here, it i...

  3. WHK Student Internship Enrollment, Mentor Participation Up More than 50 Percent | Poster

    Science.gov (United States)

    By Nancy Parrish, Staff Writer The Werner H. Kirsten Student Internship Program (WHK SIP) has enrolled the largest class ever for the 2013–2014 academic year, with 66 students and 50 mentors. This enrollment reflects a 53 percent increase in students and a 56 percent increase in mentors, compared to 2012–2013 (43 students and 32 mentors), according to Julie Hartman, WHK SIP

  4. Far-ultraviolet fluorescence of carbon monoxide in the red giant Arcturus

    International Nuclear Information System (INIS)

    Ayres, T.R.; Moos, H.W.; Linsky, J.L.

    1981-01-01

    We present evidence that many of the weak features observed with the International Ultraviolet Explorer (IUE) in the far-ultraviolet (1150--2000 A) spectrum of the archetype red giant Arcturus (K2 III) are A--X fourth positive bands of carbon monoxide excited by chromospheric emissions of O I, C I, and H I. The appearance of fluorescent CO bands near the wavelengths of commonly used indicators of high-temperature (T>2 x 10 4 K) plasma, such as C II lambda1335 and C IV lambda1548, introduces a serious ambiguity in diagnosing the presence of hot material in the outer atmospheres of the cool giants by means of low-dispersion IUE spectra

  5. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  6. Recent changes in carbon dioxide, carbon monoxide and methane and the implications for global climate change

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Conway, T.J.; Dlugokencky, E.J.; Tans, P.P. [National Oceanic and Atmospheric Administration, Boulder, CO (United States). Climate Monitoring and Diagnostics Lab.

    1995-01-01

    The article reviews figures for published data on recent changes of atmospheric levels of carbon dioxide, carbon monoxide and methane in terms of their sources and sinks. The largest source of CO{sub 2} is the combustion of fossil fuels, followed by emissions from deforestation and the oxidation of CO to CO{sub 2}. Carbon monoxide has an indirect influence on the earth`s radiative balance, as if levels of CO increase, levels of OH radicals decline which affects removal of other gases oxidised by this radical, notably CH{sub 4}. Major sources of CO are fossil fuel combustion, emissions from biomass, and oxidation of atmospheric CH{sub 4} and other non-methane hydrocarbons. The latest measurements suggest the depressed growth rates of CO{sub 2}, CO and CH{sub 4} have began to recover. Reasons for this are suggested. Future monitoring of atmospheric species in laboratories around the world, coupled with information on the isotopic signature of the trace gases, will improve our understanding of possible causes for trends in these gases. This will be invaluable in making policy decisions regarding future climate change. 34 refs., 4 figs.

  7. Retinal venous blood carbon monoxide response to bright light in male pigs: A preliminary study.

    Science.gov (United States)

    Oren, Dan A; Duda, Magdalena; Kozioł, Katarzyna; Romerowicz-Misielak, Maria; Koziorowska, Anna; Sołek, Przemysław; Nowak, Sławomir; Kulpa, Magdalena; Koziorowski, Marek

    2017-03-01

    The physical mechanism by which light is absorbed in the eye and has antidepressant and energizing effects in Seasonal Affective Disorder and other forms of psychiatric major depression is of scientific interest. This study was designed to explore one specific aspect of a proposed humoral phototransduction mechanism, namely that carbon monoxide (CO) levels increase in retinal venous blood in response to bright light. Eleven mature male pigs approximately six months of age were kept for 7days in darkness and fasted for 12h prior to surgery. Following mild sedation, anesthesia was induced. Silastic catheters were inserted into the dorsal nasal vein through the angular vein of the eye to reach the ophthalmic sinus, from which venous blood outflowing from the eye area was collected. The animals were exposed to 5000lx of fluorescent-generated white light. CO levels in the blood were analyzed by gas chromatography before and after 80min of light exposure. At baseline, mean CO levels in the retinal venous blood were 0.43±0.05(SE)nmol/ml. After bright light, mean CO levels increased to 0.54±0.06nmol/ml (two-tailed t-test plight exposure raises carbon monoxide levels in ophthalmic venous blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Solubility of carbon monoxide in bio-oil compounds

    International Nuclear Information System (INIS)

    Qureshi, Muhammad Saad; Le Nedelec, Tom; Guerrero-Amaya, Hernando; Uusi-Kyyny, Petri; Richon, Dominique; Alopaeus, Ville

    2017-01-01

    Highlights: • CO solubility was measured in four bio-oil compounds using static-analytic VLE equipment. • A comparison on the performance of different EoS (PC-SAFT, SRK and PR) was made. • Modelling of polar compounds with Polar PC-SAFT was tested. • Polar PC-SAFT is not needed for weakly polar compounds (μ < 1.0 D). - Abstract: The solubility of carbon monoxide is measured in four different bio-oil compounds (furan, diacetyl, 2-methylfuran, and trans-crotonaldehyde) at temperatures (273.15, 283.15, 298.15, and 323.15 K) and pressures up to 8 MPa using a static-analytical VLE measurement method. The equipment was validated by measuring the solubility of CO 2 in methanol at 298.15 K and pressures (P = 2.9–5.7 MPa). The results were compared with the abundantly available literature values. PC-SAFT, Polar PC-SAFT (PPC-SAFT), and Cubic (SRK, PR) EoS, part of commercial process simulator Aspen Plus V. 8.6, are used here for modelling purpose. The pure component parameters needed for PC-SAFT and PPC-SAFT EoS models, are regressed using the experimental liquid density and vapour pressure data of the pure components. It was observed that furan, 2-methylfuran and diacetyl, having weak dipole moments (μ < 1.0 D), could be modelled reasonably well without the addition of polar contribution using conventional PC-SAFT, while it is recommended to use PPC-SAFT for the description of a polar compound like trans-crotonaldehyde (μ ∼ 3.67 D). It was observed that SRK and PR EoS have similar predictive ability in comparison to PC-SAFT for a mixture of CO with weakly polar compounds in this study. A comparison between the performances of EoS models was made in two ways: first by setting the binary interaction parameter k ij to zero, and second by adjusting a temperature-dependent binary interaction parameter (k ij ). All the models perform with comparable accuracy with adjusted binary interaction parameters. However, due to the large differences between the chemical and

  9. [Etiology of combined inhalational hydrocyanic acid and carbon monoxide poisoning].

    Science.gov (United States)

    Sigrist, T; Dirnhofer, R

    1979-01-01

    A young man was found dead in a kitchen, that was partly burnt. Autopsy revealed, as cause of death, a combined intoxication following inhalation of carbon monoxide and hydrocyanic acid. Own investigations on the pyrolysis of pieces of furniture found in the kitchen (plastic plates containing melamine and plates containing formaldehyde) showed, that hydrocyanic acid was liberated through combustion of such substances and inhaled by the victim. The poisoning picture is discussed, and discussion includes especially considerations on the peculiar sensitivity of the brain toward the action of hydrocyanic acid and the relative insensitivity of the heart muscle. It is thought that the cause of such sensitivity difference lies in the physiological differences of the intracellular energy production. Finally the dangers of combustion gases developing from burning plastic materials are reemphasized.

  10. Review: hemodynamic response to carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Penney, D.G.

    1988-04-01

    Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. Augmented cardiac output usually observed with moderate COHb may be compromised in more sever poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.

  11. Prediction of half-marathon race time in recreational female and male runners.

    Science.gov (United States)

    Knechtle, Beat; Barandun, Ursula; Knechtle, Patrizia; Zingg, Matthias A; Rosemann, Thomas; Rüst, Christoph A

    2014-01-01

    Half-marathon running is of high popularity. Recent studies tried to find predictor variables for half-marathon race time for recreational female and male runners and to present equations to predict race time. The actual equations included running speed during training for both women and men as training variable but midaxillary skinfold for women and body mass index for men as anthropometric variable. An actual study found that percent body fat and running speed during training sessions were the best predictor variables for half-marathon race times in both women and men. The aim of the present study was to improve the existing equations to predict half-marathon race time in a larger sample of male and female half-marathoners by using percent body fat and running speed during training sessions as predictor variables. In a sample of 147 men and 83 women, multiple linear regression analysis including percent body fat and running speed during training units as independent variables and race time as dependent variable were performed and an equation was evolved to predict half-marathon race time. For men, half-marathon race time might be predicted by the equation (r(2) = 0.42, adjusted r(2) = 0.41, SE = 13.3) half-marathon race time (min) = 142.7 + 1.158 × percent body fat (%) - 5.223 × running speed during training (km/h). The predicted race time correlated highly significantly (r = 0.71, p marathon race time might be predicted by the equation (r(2) = 0.68, adjusted r(2) = 0.68, SE = 9.8) race time (min) = 168.7 + 1.077 × percent body fat (%) - 7.556 × running speed during training (km/h). The predicted race time correlated highly significantly (r = 0.89, p < 0.0001) to the achieved race time. The coefficients of determination of the models were slightly higher than for the existing equations. Future studies might include physiological variables to increase the coefficients of determination of the

  12. The effect of modified atmosphere packaging with carbon monoxide on the storage quality of master-packaged fresh pork

    NARCIS (Netherlands)

    Wilkinson, B.H.P.; Janz, J.A.M.; Morel, P.C.H.; Purchas, R.W.; Hendriks, W.H.

    2006-01-01

    Modified atmosphere packaging with carbon dioxide is effective for prolonging shelf-life of fresh meat. Addition of carbon monoxide to the system provides the advantage of enhancing meat colour. The study objective was to determine the effect of CO2-MAP + 0.4% CO, vs. 100% CO2-MAP, on the

  13. Multiple Victims of Carbon Monoxide Poisoning in the Aftermath of a Wildfire: A Case Series

    Directory of Open Access Journals (Sweden)

    Luís Ramos dos Santos

    2018-03-01

    Conclusion: Use of hyperbaric oxygen appears to have reduced the incidence of the syndrome. This seems to be the first Portuguese series reporting use of hyperbaric oxygen in carbon monoxide poisoning due to wildfires. The authors intend to alert to the importance of referral of these patients because the indications and benefits of this treatment are well documented. This is especially important given the ever-growing issue of wildfires in Portugal.

  14. A comparison of methods of determining the 100 percent survival of preserved red cells

    International Nuclear Information System (INIS)

    Valeri, C.R.; Pivacek, L.E.; Ouellet, R.; Gray, A.

    1984-01-01

    Studies were done to compare three methods to determine the 100 percent survival value from which to estimate the 24-hour posttransfusion survival of preserved red cells. The following methods using small aliquots of 51 Cr-labeled autologous preserved red cells were evaluated: First, the 125 I-albumin method, which is an indirect measurement of the recipient's red cell volume derived from the plasma volume measured using 125 I-labeled albumin and the total body hematocrit. Second, the body surface area method (BSA) in which the recipient's red cell volume is derived from a body surface area nomogram. Third, an extrapolation method, which extrapolates to zero time the radioactivity associated with the red cells in the recipient's circulation from 10 to 20 or 15 to 30 minutes after transfusion. The three methods gave similar results in all studies in which less than 20 percent of the transfused red cells were nonviable (24-hour posttransfusion survival values of between 80-100%), but not when more than 20 percent of the red cells were nonviable. When 21 to 35 percent of the transfused red cells were nonviable (24-hour posttransfusion survivals of 65 to 79%), values with the 125 I-albumin method and the body surface area method were about 5 percent lower (p less than 0.001) than values with the extrapolation method. When greater than 35 percent of the red cells were nonviable (24-hour posttransfusion survival values of less than 65%), values with the 125 I-albumin method and the body surface area method were about 10 percent lower (p less than 0.001) than those obtained by the extrapolation method

  15. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases

    Directory of Open Access Journals (Sweden)

    A. Mishra

    2011-05-01

    Full Text Available In this review, recent works on the preferential oxidation of carbon monoxide in hydrogen rich gases for fuel cell applications are summarized. H2 is used as a fuel for polymer-electrolyte membrane fuel cell (PEMFC. It is produced by reforming of natural gas or liquid fuels followed by water gas shift reaction. The produced gas consists of H2, CO, and CO2. In which CO content is around 1%, which is highly poisonous for the Pt anode of the PEMFC so that further removal of CO is needed. Catalytic preferential oxidation of CO (CO-PROX is one of the most suitable methods of purification of H2 because of high CO conversion rate at low temperature range, which is preferable for PEMFC operating conditions. Catalysts used for COPROX are mainly noble metal based; gold based and base metal oxide catalysts among them Copper-Ceria based catalysts are the most appropriate due to its low cost, easy availability and result obtained by these catalysts are comparable with the conventional noble metal catalysts. Copyright © 2011 BCREC UNDIP. All rights reserved(Received: 22nd October 2010, Revised: 12nd January 2011, Accepted: 19th January 2011[How to Cite: A. Mishra, R. Prasad. (2011. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases. Bulletin of Chemical Reaction Engineering & Catalysis, 6 (1: 1-14. doi:10.9767/bcrec.6.1.191.1-14][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.1.191.1-14 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/191] | View in 

  16. Carbon Monoxide Distribution over Peninsular Malaysia from the Atmospheric Infrared Sounder (AIRS)

    Science.gov (United States)

    Rajab, Jaso M.; MatJafri, M. Z.; Lim, H. S.; Abdullah, K.

    2009-07-01

    The Atmospheric Infrared Sounder (AIRS) onboard NASA's Aqua satellite. It daily coverage of ˜70% of the planet represents a significant evolutionary advance in satellite traces gas remote sensing. AIRS, the part of a large international investment to upgrade the operational meteorological satellite systems, is first of the new generation of meteorological advanced sounders for operational and research use, Providing New Insights into Weather and Climate for the 21st Century. Carbon monoxide (CO) is a ubiquitous, an indoor and outdoor air pollutant, is not a significant greenhouse gas as it absorbs little infrared radiation from the Earth. However, it does have an influence on oxidization in the atmosphere through interaction with hydroxyl radicals (OH), which also react with methane, halocarbons and tropospheric ozone. It produced by the incomplete combustion of fossil fuels and biomass burning, and that it has a role as a smog. The aim of this investigation is to study the (CO) carbon monoxide distribution over Peninsular Malaysia. The land use map of the Peninsular Malaysia was conducted by using CO total column amount, obtained from AIRS data, the map & data was processed and analyzed by using Photoshop & SigmaPlot 11.0 programs and compared for timing of various (day time) (28 August 2005 & 29 August 2007) for both direct comparison and the comparison using the same a priori profile, the CO concentrations in 28/8/2005 higher. The CO maps were generated using Kriging Interpolation technique. This interpolation technique produced high correlation coefficient, R2 and low root mean square error, RMS for CO. This study provided useful information for influence change of CO concentration on varies temperature.

  17. Deteriorations of pulmonary function, elevated carbon monoxide levels and increased oxidative stress amongst water-pipe smokers

    Directory of Open Access Journals (Sweden)

    Funda Karaduman Yalcin

    2017-10-01

    Full Text Available Objectives: A water pipe (hookah is a tobacco smoking tool which is thought to be more harmless than a cigarette, and there are no adequate studies about its hazards to health. Water-pipe smoking is threatening health of the youth in the world today. The objective of this study has been to investigate the carbon monoxide (CO levels in breath, examine the changes in pulmonary function tests (PFT and to assess the change of the oxidative stress parameters in blood after smoking a water pipe. Material and Methods: This study is a cross-sectional analytical study that has included 50 volunteers who smoke a water pipe and the control group of 50 volunteers who smoke neither a cigarette nor a water pipe. Carbon monoxide levels were measured in the breath and pulmonary function tests (PFTs were performed before and after smoking a water pipe. Blood samples were taken from either the volunteer control group or water-pipe smokers group after smoking a water pipe for the purpose of evaluation of the parameters of oxidative stress. Results: Carbon monoxide values were measured to be 8.08±7.4 ppm and 28.08±16.5 ppm before and after smoking a water pipe, respectively. This increment was found statistically significant. There were also significant reductions in PFTs after smoking a water pipe. Total oxidative status (TOS, total antioxidant status (TAS and oxidative stress index (OSI were found prominently higher after smoking a water pipe for the group of water-pipe smokers than for the control group. Conclusions: This study has shown that water-pipe smoking leads to deterioration in pulmonary function and increases oxidative stress. To the best of our knowledge this study is the only one that has shown the effect of water-pipe smoking on oxidative stress. More studies must be planned to show the side effects of water-pipe habit and protective policies should be planned especially for young people in Europe. Int J Occup Med Environ Health 2017;30(5:731

  18. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    Science.gov (United States)

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  19. The immunomodulatory role of carbon monoxide during transplantation

    Directory of Open Access Journals (Sweden)

    Amano Mariane

    2013-01-01

    Full Text Available Abstract The number of organ and tissue transplants has increased worldwide in recent decades. However, graft rejection, infections due to the use of immunosuppressive drugs and a shortage of graft donors remain major concerns. Carbon monoxide (CO had long been regarded solely as a poisonous gas. Ultimately, physiological studies unveiled the endogenous production of CO, particularly by the heme oxygenase (HO-1 enzyme, recognizing CO as a beneficial gas when used at therapeutic doses. The protective properties of CO led researchers to develop uses for it, resulting in devices and molecules that can deliver CO in vitro and in vivo. The resulting interest in clinical investigations was immediate. Studies regarding the CO/HO-1 modulation of immune responses and their effects on various immune disorders gave rise to transplantation research, where CO was shown to be essential in the protection against organ rejection in animal models. This review provides a perspective of how CO modulates the immune system to improve transplantation and suggests its use as a therapy in the field.

  20. Brain CT scan in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    We, En-Huei

    1986-01-01

    The brain CT findings in 19 patients with acute carbon monoxide poisoning was analysed and the emphasis was placed on the relationship between CT findings and prognosis. Five had a normal manifestation in CT ; eight had the findings of ovoid or patchy low density area in globus pallidus, bilateral or unlateral, during the second day to fifth week after poisoning, and the low density areas were decreasing and blurring in edge in follow up and at last disappeared during 3 - 14 weeks in three cases of them ; nine showed the appearance of diffuse low density of white matter and of globus pallidus in some of them ; two had an appearance of brain atrophy. The pathology of CT findings mentioned above may be brain edema, necrosis, malacia and degeneration in gray matter and globus pallidus. The result suggested the cases with normal CT manifestation, cerebral edema and decreasing and disappearing low density area had a good prognosis, in contrary, the cases with persistant low density in globus pallidus had a poorer prognosis. (author)

  1. General circulation model study of atmospheric carbon monoxide

    International Nuclear Information System (INIS)

    Pinto, J.P.; Yung, Y.L.; Rind, D.; Russell, G.L.; Lerner, J.A.; Hansen, J.E.; Hameed, S.

    1983-01-01

    The carbon monoxide cycle is studied by incorporating the known and hypothetical sources and sinks in a tracer model that uses the winds generated by a general circulation model. Photochemical production and loss terms, which depend on OH radical concentrations, are calculated in an interactive fashion. The computed global distribution and seasonal variations of CO are compared with observations to obtain constraints on the distribution and magnitude of the sources and sinks of CO, and on the tropospheric abundance of OH. The simplest model that accounts for available observations requires a low latitude plant source of about 1.3 x 10 15 g yr -1 , in addition to sources from incomplete combustion of fossil fuels and oxidation of methane. The globally averaged OH concentration calculated in the model is 7 x 10 5 cm -3 . Models that calculate globally averaged OH concentrations much lower than our nominal value are not consistent with the observed variability of CO. Such models are also inconsistent with measurements of CO isotopic abundances, which imply the existence of plant sources

  2. An open-terrain line source model coupled with street-canyon effects to forecast carbon monoxide at traffic roundabout.

    Science.gov (United States)

    Pandian, Suresh; Gokhale, Sharad; Ghoshal, Aloke Kumar

    2011-02-15

    A double-lane four-arm roundabout, where traffic movement is continuous in opposite directions and at different speeds, produces a zone responsible for recirculation of emissions within a road section creating canyon-type effect. In this zone, an effect of thermally induced turbulence together with vehicle wake dominates over wind driven turbulence causing pollutant emission to flow within, resulting into more or less equal amount of pollutants upwind and downwind particularly during low winds. Beyond this region, however, the effect of winds becomes stronger, causing downwind movement of pollutants. Pollutant dispersion caused by such phenomenon cannot be described accurately by open-terrain line source model alone. This is demonstrated by estimating one-minute average carbon monoxide concentration by coupling an open-terrain line source model with a street canyon model which captures the combine effect to describe the dispersion at non-signalized roundabout. The results of the modeling matched well with the measurements compared with the line source model alone and the prediction error reduced by about 50%. The study further demonstrated this with traffic emissions calculated by field and semi-empirical methods. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Nitric oxide and carbon monoxide diffusing capacity after a 1-h oxygen dive to 9 m of sea water

    NARCIS (Netherlands)

    van Ooij, P. J. A. M.; van Hulst, R. A.; Houtkooper, A.; Sterk, P. J.

    2014-01-01

    To prevent extensive pulmonary lesions in submerged oxygen divers lung function like the forced vital capacity (FVC) or the diffusing capacity for carbon monoxide (DL,co) are used to monitor pulmonary oxygen toxicity (POT). As the diffusing capacity for nitric oxide (DL,no) measures more accurately

  4. Predicting acute aquatic toxicity of structurally diverse chemicals in fish using artificial intelligence approaches.

    Science.gov (United States)

    Singh, Kunwar P; Gupta, Shikha; Rai, Premanjali

    2013-09-01

    The research aims to develop global modeling tools capable of categorizing structurally diverse chemicals in various toxicity classes according to the EEC and European Community directives, and to predict their acute toxicity in fathead minnow using set of selected molecular descriptors. Accordingly, artificial intelligence approach based classification and regression models, such as probabilistic neural networks (PNN), generalized regression neural networks (GRNN), multilayer perceptron neural network (MLPN), radial basis function neural network (RBFN), support vector machines (SVM), gene expression programming (GEP), and decision tree (DT) were constructed using the experimental toxicity data. Diversity and non-linearity in the chemicals' data were tested using the Tanimoto similarity index and Brock-Dechert-Scheinkman statistics. Predictive and generalization abilities of various models constructed here were compared using several statistical parameters. PNN and GRNN models performed relatively better than MLPN, RBFN, SVM, GEP, and DT. Both in two and four category classifications, PNN yielded a considerably high accuracy of classification in training (95.85 percent and 90.07 percent) and validation data (91.30 percent and 86.96 percent), respectively. GRNN rendered a high correlation between the measured and model predicted -log LC50 values both for the training (0.929) and validation (0.910) data and low prediction errors (RMSE) of 0.52 and 0.49 for two sets. Efficiency of the selected PNN and GRNN models in predicting acute toxicity of new chemicals was adequately validated using external datasets of different fish species (fathead minnow, bluegill, trout, and guppy). The PNN and GRNN models showed good predictive and generalization abilities and can be used as tools for predicting toxicities of structurally diverse chemical compounds. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Factors Predictive of Alcohol Consumption among Elderly People in a Rural Community: A Case Study in Phayao Province Thailand

    International Nuclear Information System (INIS)

    Hongthong, D.; Wongchaiya, P.; Somrongthong, R.; Kumar, R.

    2016-01-01

    Background: Alcohol consumption is recognized as a public health issue. Study objectives were to identify factors predictive of alcohol consumption among elderly people in Phayao province Thailand, where there was high prevalence of alcohol consumption. Methods: This was a cross-sectional study. Four hundred elderly people participated in a survey. Data was collected by face-to-face interviews. Chi-square and multivariate logistic regression were used to determine the factors predictive of alcohol consumption among the study subjects. Results: One thirds of elderly (31.7 percent) had consumed alcohol in their lifetime, and (15.7 percent) of them were current drinkers. Following univariate analysis, seven factors included gender, working, sickness, smoking, quality of life (QOL), daily activities and economic recession were identified as being significantly associated with drinking (p<0.05). Multivariate analysis revealed four factors to be predictive of alcohol among elderly people: gender (OR=6.02, 95 percent CI=3.58-10.13), smoking (OR=4.34, 95 percent CI=2.57-7.34), economic recession (OR=2.79, 95 percent, CI=1.66-4.71), and QOL (OR=1.86, 95 percent, CI=1.09-3.16). Conclusion: Gender (male) and smoking were strongly predictive factors of elderly alcohol consumption. Hence, an effort to reduce alcohol consumption should be placed on male elderly and those who smoke. (author)

  6. Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production

    Directory of Open Access Journals (Sweden)

    Perez Roberto SGM

    2005-06-01

    Full Text Available Abstract Background Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all. The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime. Methods A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams was used in this system. A low flow anesthesia (500 ml/min was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container. Results Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively. It was lower with isoflurane (2512 ppm. We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions. Conclusion All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.

  7.  Running speed during training and percent body fat predict race time in recreational male marathoners

    OpenAIRE

    Barandun U; Knechtle B; Knechtle P; Klipstein A; Rust CA; Rosemann T; Lepers R

    2012-01-01

     Background: Recent studies have shown that personal best marathon time is a strong predictor of race time in male ultramarathoners. We aimed to determine variables predictive of marathon race time in recreational male marathoners by using the same characteristics of anthropometry and training as used for ultramarathoners.Methods: Anthropometric and training characteristics of 126 recreational male marathoners were bivariately and multivariately related to marathon race times.Results...

  8. The effect of carbon monoxide on planetary haze formation

    Energy Technology Data Exchange (ETDEWEB)

    Hörst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  9. Use of pulse co-oximetry as a screening and monitoring tool in mass carbon monoxide poisoning.

    Science.gov (United States)

    Bledsoe, Bryan E; Nowicki, Kevin; Creel, James H; Carrison, Dale; Severance, Harry W

    2010-01-01

    Carbon monoxide (CO) poisoning remains a common cause of poisoning in the United States. We describe a case where responding fire department personnel encountered a sick employee with a headache at an automotive brake manufacturing plant. Using both atmospheric CO monitoring and pulse CO-oximetry technology, fire department personnel were able to diagnose the cause of the patient's illness and later identify the source of CO in the plant.

  10. Role of carboxydobacteria in consumption of atmospheric carbon monoxide by soil

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, R. (Max-Planck-Institut fuer Chemie, Mainz, Germany); Meyer, O.; Seiler, W.

    1981-08-01

    The carbon monoxide consumption rates of the carboxydobacteria Pseudomonas (Seliberia) carboxydohydrogena, P. carboxydovorans, and P. carboxydoflava were measured at high (50%) and low (0.5 ..mu..l liter/sup -1/) mixing ratios of CO in air. CO was only consumed when the bacteria had been grown under CO-autotrophic conditions. At low cell densities the CO comsumption rates measured at low CO mixing ratios were similar in cell suspensions and in mixtures of bacteria in soil. CO consumption observed in natural soil (loess, eolian sand, chernozem) as well as in suspensions or soil mixtures of carboxydobacteria showed Michaelis-Menten kinetics. Considering the difference of the K/sub m/, values and the observed V/sub max/ values, carboxydobacteria cannot contribute significantly to the consumption of atmospheric CO.

  11. Evaluation of carbon monoxide in blood samples from the second health and nutrition survey. Progress report No. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radford, E.P.

    1976-01-01

    This is a study of carbon monoxide (CO) in the blood of human subjects participating in the Second National Health and Nutrition Survey (HANES II), a detailed study of health indicators in sample populations of many communities throughout the U.S. The purpose of this aspect of the survey is to evaluate the levels of blood carboxyhemoglobin in normal individuals of all ages in typical U.S. communities, from whom accurate histories and clinical studies are available. This report gives results of the first of three years of analyses. A careful calibration of the analytical method has been completed, and more than 3000 blood samples have been analyzed. Although smoking histories are not yet available to permit evaluation of carboxyhemoglobin in non-smokers, in children under 12 years of age, blood COHb has been found to be consistently low, with less than 3% greater than 1.5% COHb. These preliminary results suggest that urban exposure to carbon monoxide among the general population is not now significant in the U.S., at least during the period of these early examinations.

  12. Carbon monoxide migratory insertion - A comparison of cationic and neutral palladium(II) complexes

    International Nuclear Information System (INIS)

    Frankcombe, K.; Cavell, K.J.; Yates, B.F.; Knott, R.B.

    1998-01-01

    With the use of ANSTO's resources and expertise and with support from AINSE, we have carried out extensive computer modelling on the mechanism of the palladium catalysed carbonylation reaction, a process which is used industrially in the conversion of carbon monoxide into biodegradable polymers. In this project, experimental and theoretical work has focussed on using Pd(II) complexes containing pyridine carboxylate ligands (NC 5 H 4 COO ) to explore the fundamental mechanistic steps. The results for subsequent steps in the catalytic cycle are presented and their implication for the design of more efficient catalysts are discussed

  13. The relation between carbon monoxide emission and visual extinction in cloud L134

    International Nuclear Information System (INIS)

    Tucker, K.D.; Dickman, R.L.; Encrenaz, P.J.; Kutner, M.L.

    1976-01-01

    Emission from the J=1→0 transition of carbon monoxide has been mapped over an area of 40' x 55' in cloud L134, and visual extinctions over the entire cloud have been obtained by means of star counts. Line intensities of > or =2 K are observable down to an extinction level of about one magnitude. From observations of the J=1→0 transition of the 13 CO isotopic species at 18 locations in the cloud, we have found a linear correlation between the local thermodynamic equilibrium (LTE) column densities of 13 CO and magnitudes of visual extinction

  14. Catalytic hydrogenation of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Wayland, B.B.

    1992-12-01

    This project is focused on developing strategies to accomplish the reduction and hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. Our approaches to this issue are based on the recognition that rhodium macrocycles have unusually favorable thermodynamic values for producing a series of intermediate implicated in the catalytic hydrogenation of CO. Observations of metalloformyl complexes produced by reactions of H{sub 2} and CO, and reductive coupling of CO to form metallo {alpha}-diketone species have suggested a multiplicity of routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in constructing energy profiles for a variety of potential pathways, and these schemes are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Variation of the electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Emerging knowledge of the factors that contribute to M-H, M-C and M-O bond enthalpies is directing the search for ligand arrays that will expand the range of metal species that have favorable thermodynamic parameters to produce the primary intermediates for CO hydrogenation. Studies of rhodium complexes are being extended to non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics. Multifunctional catalyst systems designed to couple the ability of rhodium complexes to produce formyl and diketone intermediates with a second catalyst that hydrogenates these imtermediates are promising approaches to accomplish CO hydrogenation at mild conditions.

  15. Age-specific association between percent body fat and pulmonary ...

    African Journals Online (AJOL)

    This study describes the association between percent body fat and pulmonary function among apparently normal twenty male children tidal volume aged 4 years and twenty male children aged 10 years in Ogbomoso. The mean functional residual capacity of the lung in male children aged 10 years was significantly higher ...

  16. Reactivity of niobium cluster anions with nitrogen and carbon monoxide

    Science.gov (United States)

    Mwakapumba, Joseph; Ervin, Kent M.

    1997-02-01

    Reactions of small niobium cluster anions, Nbn-(n = 2-7), with CO and N2 are investigated using a flow tube reactor (flowing afterglow) apparatus. Carbon monoxide chemisorption on niobium cluster anions occurs with faster reaction rates than nitrogen chemisorption on corresponding cluster sizes. N2 addition to niobium cluster anions is much more size-selective than is CO addition. These general trends follow those reported in the literature for reactions of neutral and cationic niobium clusters with CO and N2. Extensive fragmentation of the clusters is observed upon chemisorption. A small fraction of the larger clusters survive and sequentially add multiple CO or N2 units without fragmentation. However, chemisorption saturation is not reached at the experimentally accessible pressure and reagent concentration ranges. The thermochemistry of the adsorption processes and the nature of the adsorbed species, molecular or dissociated, are discussed.

  17. Identification of a novel percent mammographic density locus at 12q24.

    Science.gov (United States)

    Stevens, Kristen N; Lindstrom, Sara; Scott, Christopher G; Thompson, Deborah; Sellers, Thomas A; Wang, Xianshu; Wang, Alice; Atkinson, Elizabeth; Rider, David N; Eckel-Passow, Jeanette E; Varghese, Jajini S; Audley, Tina; Brown, Judith; Leyland, Jean; Luben, Robert N; Warren, Ruth M L; Loos, Ruth J F; Wareham, Nicholas J; Li, Jingmei; Hall, Per; Liu, Jianjun; Eriksson, Louise; Czene, Kamila; Olson, Janet E; Pankratz, V Shane; Fredericksen, Zachary; Diasio, Robert B; Lee, Adam M; Heit, John A; DeAndrade, Mariza; Goode, Ellen L; Vierkant, Robert A; Cunningham, Julie M; Armasu, Sebastian M; Weinshilboum, Richard; Fridley, Brooke L; Batzler, Anthony; Ingle, James N; Boyd, Norman F; Paterson, Andrew D; Rommens, Johanna; Martin, Lisa J; Hopper, John L; Southey, Melissa C; Stone, Jennifer; Apicella, Carmel; Kraft, Peter; Hankinson, Susan E; Hazra, Aditi; Hunter, David J; Easton, Douglas F; Couch, Fergus J; Tamimi, Rulla M; Vachon, Celine M

    2012-07-15

    Percent mammographic density adjusted for age and body mass index (BMI) is one of the strongest risk factors for breast cancer and has a heritable component that remains largely unidentified. We performed a three-stage genome-wide association study (GWAS) of percent mammographic density to identify novel genetic loci associated with this trait. In stage 1, we combined three GWASs of percent density comprised of 1241 women from studies at the Mayo Clinic and identified the top 48 loci (99 single nucleotide polymorphisms). We attempted replication of these loci in 7018 women from seven additional studies (stage 2). The meta-analysis of stage 1 and 2 data identified a novel locus, rs1265507 on 12q24, associated with percent density, adjusting for age and BMI (P = 4.43 × 10(-8)). We refined the 12q24 locus with 459 additional variants (stage 3) in a combined analysis of all three stages (n = 10 377) and confirmed that rs1265507 has the strongest association in the 12q24 region (P = 1.03 × 10(-8)). Rs1265507 is located between the genes TBX5 and TBX3, which are members of the phylogenetically conserved T-box gene family and encode transcription factors involved in developmental regulation. Understanding the mechanism underlying this association will provide insight into the genetics of breast tissue composition.

  18. Extension of the code COCOSYS to a dispersion code for smoke and carbon monoxide

    International Nuclear Information System (INIS)

    Sdouz, Gert; Mayrhofer, Robert

    2009-01-01

    The code COCOSYS (Containment Code SYStem) was developed by GRS in Germany to simulate processes and nuclear plant states during severe accidents in the containments of light water reactors. It contains several physical models, especially a module for aerosol behaviour. The goal of this work was to extend COCOSYS for applications in more general geometries mainly for complex public buildings. For the application in public buildings models for air condition systems and different boundary conditions according to different environments were developed. The principal application of the extended code COCOSYS is in the area of emergency situations especially in the simulation for carbon monoxide and smoke dispersion. After developing and implementing the new models several test calculations were performed to evaluate the functionality of the extended code. The comparison of the results with those of the original COCOSYS code showed no discrepancies. For the first realistic application several fire emergency scenarios in the Vienna General Hospital (AKH) were selected in agreement with the fire department of the hospital. One of the scenarios addresses the danger of carbon monoxide (CO) and smoke leaking into a fire protection section through a damaged fire protection flap. As a result of the dispersion simulation the CO-concentration in all of the rooms is obtained. Together with additional results as deposition and smoke dispersion the outcome of the simulation can be used for training. Among the next steps are the validation of the new models and the selection of critical scenarios. (author)

  19. SERIAL PERCENT-FREE PSA IN COMBINATION WITH PSA FOR POPULATION-BASED EARLY DETECTION OF PROSTATE CANCER

    Science.gov (United States)

    Ankerst, Donna Pauler; Gelfond, Jonathan; Goros, Martin; Herrera, Jesus; Strobl, Andreas; Thompson, Ian M.; Hernandez, Javier; Leach, Robin J.

    2016-01-01

    PURPOSE To characterize the diagnostic properties of serial percent-free prostate-specific antigen (PSA) in relation to PSA in a multi-ethnic, multi-racial cohort of healthy men. MATERIALS AND METHODS 6,982 percent-free PSA and PSA measures were obtained from participants in a 12 year+ Texas screening study comprising 1625 men who never underwent biopsy, 497 who underwent one or more biopsies negative for prostate cancer, and 61 diagnosed with prostate cancer. Area underneath the receiver-operating-characteristic-curve (AUC) for percent-free PSA, and the proportion of patients with fluctuating values across multiple visits were determined according to two thresholds (under 15% versus 25%) were evaluated. The proportion of cancer cases where percent-free PSA indicated a positive test before PSA > 4 ng/mL did and the number of negative biopsies that would have been spared by percent-free PSA testing negative were computed. RESULTS Percent-free PSA fluctuated around its threshold of PSA tested positive earlier than PSA in 71.4% (34.2%) of cancer cases, and among men with multiple negative biopsies and a PSA > 4 ng/mL, percent-free PSA would have tested negative in 31.6% (65.8%) instances. CONCLUSIONS Percent-free PSA should accompany PSA testing in order to potentially spare unnecessary biopsies or detect cancer earlier. When near the threshold, both tests should be repeated due to commonly observed fluctuation. PMID:26979652

  20. Evaluation of chemical transport model predictions of primary organic aerosol for air masses classified by particle-component-based factor analysis

    OpenAIRE

    C. A. Stroud; M. D. Moran; P. A. Makar; S. Gong; W. Gong; J. Zhang; J. G. Slowik; J. P. D. Abbatt; G. Lu; J. R. Brook; C. Mihele; Q. Li; D. Sills; K. B. Strawbridge; M. L. McGuire

    2012-01-01

    Observations from the 2007 Border Air Quality and Meteorology Study (BAQS-Met 2007) in Southern Ontario, Canada, were used to evaluate predictions of primary organic aerosol (POA) and two other carbonaceous species, black carbon (BC) and carbon monoxide (CO), made for this summertime period by Environment Canada's AURAMS regional chemical transport model. Particle component-based factor analysis was applied to aerosol mass spectrometer measurements made at one urban site (Windsor, ON) and two...

  1. Oxygen permeation flux through La1-ySryFeO3 limited by the carbon monoxide oxidation rate

    NARCIS (Netherlands)

    van Hassel, B.A.; van Hassel, B.A.; ten Elshof, Johan E.; Bouwmeester, Henricus J.M.

    1995-01-01

    The oxygen permeation flux through La1-ySryFeO3-δ (y = 0.1, 0.2) in a large oxygen partial pressure gradient (air/CO, CO2 mixture) was found to be limited by the carbon monoxide oxidation rate at the low oxygen partial pressure side of the membrane. The oxygen permeation flux through the membrane

  2. Kinetics of Carbon Monoxide Electro-Oxidation in Solid-Oxide Fuel Cells from Ni-YSZ Patterned-Anode Measurements

    KAUST Repository

    Hanna, J.; Lee, W. Y.; Ghoniem, A. F.

    2013-01-01

    A mathematical model is developed around the framework of a reduced mechanism describing electrochemical oxidation of carbon monoxide on Ni-YSZ patterned anodes. The electro-oxidation mechanism involves three reactions, one describing adsorption/ desorption of COonNi, and two single-electron charge-transfer steps inwhich the surface adsorbate CO(Ni) participates directly. These steps are coupled with surface transport in a reaction-diffusion model for which analytic equilibrium and steady-state solutions are derived. As much as possible, we make use of existing, independent, published information about heterogeneous chemistry, surface transport, and other model parameters. The only unknowns in our model are taken to be the kinetic rate constants of the electrochemical reactions, which we evaluate by fitting the model predictions to previously published patterned-anode experiments [B. Habibzadeh, Ph.D. Thesis, University of Maryland, College Park, MD, USA (2007)]. The results show that diffusion of CO on the Ni surface to the three-phase boundary is the rate-controlling process for CO electro-oxidation. Moreover, from a reaction standpoint, the charge-transfer process is dominated by a slow step involving CO(Ni). These findings collectively demonstrate the critical dependence of the electro-oxidation process to the direct participation of CO. © 2013 The Electrochemical Society. All rights reserved.

  3. Kinetics of Carbon Monoxide Electro-Oxidation in Solid-Oxide Fuel Cells from Ni-YSZ Patterned-Anode Measurements

    KAUST Repository

    Hanna, J.

    2013-04-17

    A mathematical model is developed around the framework of a reduced mechanism describing electrochemical oxidation of carbon monoxide on Ni-YSZ patterned anodes. The electro-oxidation mechanism involves three reactions, one describing adsorption/ desorption of COonNi, and two single-electron charge-transfer steps inwhich the surface adsorbate CO(Ni) participates directly. These steps are coupled with surface transport in a reaction-diffusion model for which analytic equilibrium and steady-state solutions are derived. As much as possible, we make use of existing, independent, published information about heterogeneous chemistry, surface transport, and other model parameters. The only unknowns in our model are taken to be the kinetic rate constants of the electrochemical reactions, which we evaluate by fitting the model predictions to previously published patterned-anode experiments [B. Habibzadeh, Ph.D. Thesis, University of Maryland, College Park, MD, USA (2007)]. The results show that diffusion of CO on the Ni surface to the three-phase boundary is the rate-controlling process for CO electro-oxidation. Moreover, from a reaction standpoint, the charge-transfer process is dominated by a slow step involving CO(Ni). These findings collectively demonstrate the critical dependence of the electro-oxidation process to the direct participation of CO. © 2013 The Electrochemical Society. All rights reserved.

  4. SOLUBILITY PREDICTION OF SULFONAMIDES AT VARIOUS TEMPERATURES USING A SINGLE DETERMINATION

    Directory of Open Access Journals (Sweden)

    JALAL HANAEE

    2005-04-01

    Full Text Available Solubility of sulphamethoxazole, sulphisoxazole and sulphasalazine in six solvents namely water,methanol, ethanol, 1-propanol, acetone and chloroform were determined at 15, 25, 37 and 45 °C. Two models derived from the Hildebrand solubility approach are proposed for solubility prediction at different temperatures using a single determination. The experimental data of the present work as well as data gathered from the literature have been employed to investigate the accuracy and prediction capability of the proposed models. The overall percent deviations between the predicted and experimental values were 10.78 and 14.63% which were comparable to those of the classical two and three parameter models. The proposed models were much superior to the two pure predictive models i.e., the ones which do not require experimental solubility determination, as the overall percent deviations produced by the latter models were 150.09 and 161.00%.

  5. Clinical and neuropathological findings of acute carbon monoxide toxicity in chihuahuas following smoke inhalation.

    Science.gov (United States)

    Kent, Marc; Creevy, Kate E; Delahunta, Alexander

    2010-01-01

    Three adult Chihuahuas were presented for evaluation after smoke inhalation during a house fire. All three dogs received supportive care and supplemental oxygen. After initial improvement, the dogs developed seizures. Despite anticonvulsant therapy and supportive care, the dogs died. The brains of two dogs were examined. Lesions were identified that were compatible with acute carbon monoxide (CO) toxicity. Lesions were confined to the caudate nucleus, the globus pallidus, and the substantia nigra bilaterally, as well as the cerebellum, cerebral cortex, and dorsal thalamus. This case report describes the clinicopathological sequelae in acute CO toxicity.

  6. Deep Conversion of Carbon Monoxide to Hydrogen and Formation of Acetate by the Anaerobic Thermophile Carboxydothermus hydrogenoformans

    OpenAIRE

    Henstra, Anne M.; Stams, Alfons J. M.

    2011-01-01

    Carboxydothermus hydrogenoformans is a thermophilic strictly anaerobic bacterium that catalyses the water gas shift reaction, the conversion of carbon monoxide with water to molecular hydrogen and carbon dioxide. The thermodynamically favorable growth temperature, compared to existing industrial catalytic processes, makes this organism an interesting alternative for production of cheap hydrogen gas suitable to fuel CO-sensitive fuel cells in a future hydrogen economy, provided sufficiently lo...

  7. Diatomic infrared gas-dynamic laser

    International Nuclear Information System (INIS)

    Mckenzie, R.L.

    1971-01-01

    A laser is provided which utilizes the infrared vibration rotation transitions of a diatomic gas such as carbon monoxide. The laser action is produced by an active diatomic gas such as carbon monoxide mixed with a vibrationally resonant pumping gas such as nitrogen. In addition, a noble gas such as argon may be employed as a third gas in the mixture. The gas mixture contains from 1 to 80 vol percent of the active gas based on the pumping gas, and the third gas, if used, can constitute up to 90 percent of the total gas volume. A number of significantly different wavelengths can be produced by the laser. A single laser may contain several optical resonators at different locations, so that the desired wave length can be selected at will

  8. CRED Cumulative Map of Percent Scleractinian Coral Cover at Kauai, 2005

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  9. CRED Cumulative Map of Percent Scleractinian Coral Cover at Niihau, 2005

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  10. CRED Cumulative Map of Percent Scleractinian Coral Cover at Stingray Shoals

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  11. CRED Cumulative Map of Percent Scleractinian Coral Cover at Molokai, 2005

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  12. CRED Cumulative Map of Percent Scleractinian Coral Cover at Ofu & Olosega

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  13. CRED Cumulative Map of Percent Scleractinian Coral Cover at Ta'u

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  14. CRED Cumulative Map of Percent Scleractinian Coral Cover at Guam, 2003

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This map displays optical validation observation locations and percent coverage of scleractinian coral overlaid on bathymetry.

  15. External validation of multivariable prediction models: a systematic review of methodological conduct and reporting

    Science.gov (United States)

    2014-01-01

    Background Before considering whether to use a multivariable (diagnostic or prognostic) prediction model, it is essential that its performance be evaluated in data that were not used to develop the model (referred to as external validation). We critically appraised the methodological conduct and reporting of external validation studies of multivariable prediction models. Methods We conducted a systematic review of articles describing some form of external validation of one or more multivariable prediction models indexed in PubMed core clinical journals published in 2010. Study data were extracted in duplicate on design, sample size, handling of missing data, reference to the original study developing the prediction models and predictive performance measures. Results 11,826 articles were identified and 78 were included for full review, which described the evaluation of 120 prediction models. in participant data that were not used to develop the model. Thirty-three articles described both the development of a prediction model and an evaluation of its performance on a separate dataset, and 45 articles described only the evaluation of an existing published prediction model on another dataset. Fifty-seven percent of the prediction models were presented and evaluated as simplified scoring systems. Sixteen percent of articles failed to report the number of outcome events in the validation datasets. Fifty-four percent of studies made no explicit mention of missing data. Sixty-seven percent did not report evaluating model calibration whilst most studies evaluated model discrimination. It was often unclear whether the reported performance measures were for the full regression model or for the simplified models. Conclusions The vast majority of studies describing some form of external validation of a multivariable prediction model were poorly reported with key details frequently not presented. The validation studies were characterised by poor design, inappropriate handling

  16. Analysis association of milk fat and protein percent in quantitative ...

    African Journals Online (AJOL)

    SAM

    2014-05-14

    May 14, 2014 ... African Journal of Biotechnology. Full Length ... quantitative trait locus (QTLs) on chromosomes 1, 6, 7 and 20 in ... Protein and fat percent as content of milk are high-priority criteria for financial aims and selection of programs ...

  17. Enhancement of p-type mobility in tin monoxide by native defects

    KAUST Repository

    Granato, D. B.

    2013-05-31

    Transparent p-type materials with good mobility are needed to build completely transparent p-n junctions. Tin monoxide (SnO) is a promising candidate. A recent study indicates great enhancement of the hole mobility of SnO grown in Sn-rich environment [E. Fortunato et al., Appl. Phys. Lett. 97, 052105 (2010)]. Because such an environment makes the formation of defects very likely, we study defect effects on the electronic structure to explain the increased mobility. We find that Sn interstitials and O vacancies modify the valence band, inducing higher contributions of the delocalized Sn 5p orbitals as compared to the localized O 2p orbitals, thus increasing the mobility. This mechanism of valence band modification paves the way to a systematic improvement of transparent p-type semiconductors.

  18. Carbon monoxide exposure and information processing during perceptual-motor performance

    Energy Technology Data Exchange (ETDEWEB)

    Mihevic, P.M.; Gliner, J.A.; Horvath, S.M.

    1983-01-01

    This study examined the influence of exposure to ambient carbon monoxide resulting in final carboxyhemoglobin (COHb) levels of approximately 5.0% on the ability to process information during motor performance. Subjects (n . 16) performed a primary reciprocal tapping task and a secondary digit manipulation task singly and/or concurrently during 2.5 h exposure to room air (0 ppm CO) or 100 ppm CO. Five levels of tapping difficulty and two levels of digit manipulation were employed. Tapping performance was unaffected when COHb levels were as high as 5%. However, at this level of COHb it was noted that CO exposure interacted with task difficulty of both tasks to influence reaction time on the digit manipulation task. It was concluded that motor performance was not influenced by exposure to CO leading to COHb concentrations of 5%. Task difficulty was a significant factor mediating behavioral effects of CO exposure.

  19. Carbon monoxide exposure and information processing during perceptual-motor performance

    Energy Technology Data Exchange (ETDEWEB)

    Mihevic, P.M.; Gliner, J.A.; Horvath, S.M.

    1983-04-01

    This study examined the influence of exposure to ambient carbon monoxide resulting in final carboxyhemoglobin (COHb) levels of approximately 5.0% on the ability to process information during motor performance. Subjects (n = 16) performed a primary reciprocal tapping task and a secondary digit manipulation task singly and/or concurrently during 2.5 h exposure to room air (0 ppm CO) or 100 ppm CO. Five levels of tapping difficulty and two levels of digit manipulation were employed. Tapping performance was unaffected when COHb levels were as high as 5%. However, at this level of COHb it was noted that CO exposure interacted with task difficulty of both tasks to influence reaction time on the digit manipulation task. It was concluded that motor performance was not influenced by exposure to CO leading to COHb concentrations of 5%. Task difficulty was a significant factor mediating behavioral effects of CO exposure.

  20. Dispersive oxidation of rhodium clusters in Na-Y by the combined action of zeolite protons and carbon monoxide

    International Nuclear Information System (INIS)

    Wong, T.T.T.; Sachtler, W.M.H.; Stakheev, A.Yu.

    1992-01-01

    This paper uses x-ray photoelectron spectroscopy, fourier transform infrared spectroscopy and temperature programmed mass-spectrometric analysis to study the interaction of Na-Y supported rhodium with hydrogen, carbon monoxide, and zeolite protons. This report attempts to clarify the mechanism of dispersive oxidation of reduced Rh particles in the presence of CO, leading to the formation of Rh + (CO) 2 cations

  1. DNA pooling base genome-wide association study identifies variants at NRXN3 associated with delayed encephalopathy after acute carbon monoxide poisoning.

    Directory of Open Access Journals (Sweden)

    Wenqiang Li

    Full Text Available Delayed encephalopathy after acute carbon monoxide poisoning (DEACMP is more characteristic of anoxic encephalopathy than of other types of anoxia. Those who have the same poisoning degree and are of similar age and gender have a greater risk of getting DEACMP. This has made it clear that there are obvious personal differences. Genetic factors may play a very important role. The authors performed a genome-wide association study involving pooling of DNA obtained from 175 patients and 244 matched acute carbon monoxide poisoning without delayed encephalopathy controls. The Illumina HumanHap 660 Chip array was used for DNA pools. Allele frequencies of all SNPs were compared between delayed encephalopathy after acute carbon monoxide poisoning and control groups and ranked. A total of 123 SNPs gave an OR >1.4. Of these, 46 mapped in or close to known genes. Forty-eight SNPs located in 19 genes were associated with DEACMP after correction for 5% FDR in the genome-wide association of pooled DNA. Two SNPs (rs11845632 and rs2196447 locate in the Neurexin 3 gene were selected for individual genotyping in all samples and another cohort consisted of 234 and 271 controls. There were significant differences in the genotype and allele frequencies of rs11845632 and rs2196447 between the DEACMP group and controls group (all P-values <0.05. This study describes a positive association between Neurexin 3 and controls in the Han Chinese population, and provides genetic evidence to support the susceptibility of DEACMP, which may be the resulting interaction of environmental and genetic factors.

  2. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    International Nuclear Information System (INIS)

    Geballe, T.R.; Lacy, J.H.; Beck, S.C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is proabably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial

  3. The 8 micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Science.gov (United States)

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1979-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (about 600 K) layers of a circumstellar cloud at a distance of approximately 0.15 arcsec from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  4. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Science.gov (United States)

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  5. Study of extraterrestrial disposal of radioactive wastes. Part 3: Preliminary feasibility screening study of space disposal of the actinide radioactive wastes with 1 percent and 0.1 percent fission product contamination

    Science.gov (United States)

    Hyland, R. E.; Wohl, M. L.; Finnegan, P. M.

    1973-01-01

    A preliminary study was conducted of the feasibility of space disposal of the actinide class of radioactive waste material. This waste was assumed to contain 1 and 0.1 percent residual fission products, since it may not be feasible to completely separate the actinides. The actinides are a small fraction of the total waste but they remain radioactive much longer than the other wastes and must be isolated from human encounter for tens of thousands of years. Results indicate that space disposal is promising but more study is required, particularly in the area of safety. The minimum cost of space transportation would increase the consumer electric utility bill by the order of 1 percent for earth escape and 3 percent for solar escape. The waste package in this phase of the study was designed for normal operating conditions only; the design of next phase of the study will include provisions for accident safety. The number of shuttle launches per year required to dispose of all U.S. generated actinide waste with 0.1 percent residual fission products varies between 3 and 15 in 1985 and between 25 and 110 by 2000. The lower values assume earth escape (solar orbit) and the higher values are for escape from the solar system.

  6. Predictive Models of the Hydrological Regime of Unregulated Streams in Arizona

    Science.gov (United States)

    Anning, David W.; Parker, John T.C.

    2009-01-01

    Three statistical models were developed by the U.S. Geological Survey in cooperation with the Arizona Department of Environmental Quality to improve the predictability of flow occurrence in unregulated streams throughout Arizona. The models can be used to predict the probabilities of the hydrological regime being one of four categories developed by this investigation: perennial, which has streamflow year-round; nearly perennial, which has streamflow 90 to 99.9 percent of the year; weakly perennial, which has streamflow 80 to 90 percent of the year; or nonperennial, which has streamflow less than 80 percent of the year. The models were developed to assist the Arizona Department of Environmental Quality in selecting sites for participation in the U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program. One model was developed for each of the three hydrologic provinces in Arizona - the Plateau Uplands, the Central Highlands, and the Basin and Range Lowlands. The models for predicting the hydrological regime were calibrated using statistical methods and explanatory variables of discharge, drainage-area, altitude, and location data for selected U.S. Geological Survey streamflow-gaging stations and a climate index derived from annual precipitation data. Models were calibrated on the basis of streamflow data from 46 stations for the Plateau Uplands province, 82 stations for the Central Highlands province, and 90 stations for the Basin and Range Lowlands province. The models were developed using classification trees that facilitated the analysis of mixed numeric and factor variables. In all three models, a threshold stream discharge was the initial variable to be considered within the classification tree and was the single most important explanatory variable. If a stream discharge value at a station was below the threshold, then the station record was determined as being nonperennial. If, however, the stream discharge was above the threshold

  7. Demographic Prediction of Juvenile Delinquency across and within Delinquency Levels.

    Science.gov (United States)

    Fink, Michael D.; Truckenmiller, James L.

    Demographic prediction of juvenile delinquency has been hampered by the heterogeniety of youth samples. In an attempt to correct for sampling bias in predicting juvenile delinquency, 1,689 male and female youths(aged 12 to 19, drawn from a 6 percent systematic, census tract, random sample of Pennsylvania school youths) completed the Youth Needs…

  8. 46 CFR 42.20-7 - Flooding standard: Type “B” vessel, 60 percent reduction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Flooding standard: Type âBâ vessel, 60 percent reduction... DOMESTIC AND FOREIGN VOYAGES BY SEA Freeboards § 42.20-7 Flooding standard: Type “B” vessel, 60 percent... applied to the following flooding standards: (1) If the vessel is 225 meters (738 feet) or less in length...

  9. Residential carbon monoxide poisoning from motor vehicles.

    Science.gov (United States)

    Hampson, Neil B

    2011-01-01

    Although morbidity and mortality from accidental carbon monoxide (CO) poisoning are high in the United States, identification of common but poorly recognized sources should help prevention efforts. The study aimed to describe CO poisoning of home occupants due to a vehicle left running in an attached garage. News stories reporting incidents of US CO poisoning were collected daily from March 2007 to September 2009 via a news.Google.com search and data extracted. Patients were individuals reported in the media to have been poisoned with CO in their home by a vehicle running in the attached garage. Main outcome measures were frequency of occurrence, geographic distribution, patient demographics, and mortality. Of 837 CO poisoning incidents reported in US news media over 2 and a half years, 59 (8%) were the result of a vehicle left running in the garage. The elderly were disproportionately affected, with incidents most common in states with larger elderly populations and 29% of cases with age specified occurring in individuals older than 80 years. Among those older than 80 years, 15 of 17 were found dead at the scene. Residential CO poisoning from a vehicle running in the garage is common, disproportionately affects the elderly, has a high mortality rate, and should be preventable with a residential CO alarm. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. A multigene assay to predict recurrence of tamoxifen-treated, node-negative breast cancer.

    Science.gov (United States)

    Paik, Soonmyung; Shak, Steven; Tang, Gong; Kim, Chungyeul; Baker, Joffre; Cronin, Maureen; Baehner, Frederick L; Walker, Michael G; Watson, Drew; Park, Taesung; Hiller, William; Fisher, Edwin R; Wickerham, D Lawrence; Bryant, John; Wolmark, Norman

    2004-12-30

    The likelihood of distant recurrence in patients with breast cancer who have no involved lymph nodes and estrogen-receptor-positive tumors is poorly defined by clinical and histopathological measures. We tested whether the results of a reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay of 21 prospectively selected genes in paraffin-embedded tumor tissue would correlate with the likelihood of distant recurrence in patients with node-negative, tamoxifen-treated breast cancer who were enrolled in the National Surgical Adjuvant Breast and Bowel Project clinical trial B-14. The levels of expression of 16 cancer-related genes and 5 reference genes were used in a prospectively defined algorithm to calculate a recurrence score and to determine a risk group (low, intermediate, or high) for each patient. Adequate RT-PCR profiles were obtained in 668 of 675 tumor blocks. The proportions of patients categorized as having a low, intermediate, or high risk by the RT-PCR assay were 51, 22, and 27 percent, respectively. The Kaplan-Meier estimates of the rates of distant recurrence at 10 years in the low-risk, intermediate-risk, and high-risk groups were 6.8 percent (95 percent confidence interval, 4.0 to 9.6), 14.3 percent (95 percent confidence interval, 8.3 to 20.3), and 30.5 percent (95 percent confidence interval, 23.6 to 37.4). The rate in the low-risk group was significantly lower than that in the high-risk group (P<0.001). In a multivariate Cox model, the recurrence score provided significant predictive power that was independent of age and tumor size (P<0.001). The recurrence score was also predictive of overall survival (P<0.001) and could be used as a continuous function to predict distant recurrence in individual patients. The recurrence score has been validated as quantifying the likelihood of distant recurrence in tamoxifen-treated patients with node-negative, estrogen-receptor-positive breast cancer. Copyright 2004 Massachusetts Medical Society.

  11. In situ disordering of monoclinic titanium monoxide Ti5O5 studied by transmission electron microscope TEM.

    Science.gov (United States)

    Rempel, А А; Van Renterghem, W; Valeeva, А А; Verwerft, M; Van den Berghe, S

    2017-09-07

    The superlattice and domain structures exhibited by ordered titanium monoxide Ti 5 O 5 are disrupted by low energy electron beam irradiation. The effect is attributed to the disordering of the oxygen and titanium sublattices. This disordering is caused by the displacement of both oxygen and titanium atoms by the incident electrons and results in a phase transformation of the monoclinic phase Ti 5 O 5 into cubic B1 titanium monoxide. In order to determine the energies required for the displacement of titanium or oxygen atoms, i.e. threshold displacement energies, a systematic study of the disappearance of superstructure reflections with increasing electron energy and electron bombardment dose has been performed in situ in a transmission electron microscope (TEM). An incident electron energy threshold between 120 and 140 keV has been observed. This threshold can be ascribed to the displacements of titanium atoms with 4 as well as with 5 oxygen atoms as nearest neighbors. The displacement threshold energy of titanium atoms in Ti 5 O 5 corresponding with the observed incident electron threshold energy lies between 6.0 and 7.5 eV. This surprisingly low value can be explained by the presence of either one or two vacant oxygen lattice sites in the nearest neighbors of all titanium atoms.

  12. 0.1–2000 eV electron impact cross sections for dichlorine monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Goswami, Biplab; Gupta, Dhanoj; Antony, Bobby, E-mail: bka.ism@gmail.com

    2014-03-01

    Highlights: • Quantum mechanical models were used to find TCS for e-Cl{sub 2}O from 0.1 to 2000 eV. • R-matrix method at low energies (<13 eV) and SCOP at high energies (13–2000 eV). • Besides TCS, DCS, excitation cross section and momentum transfer CS also predicted. • R-matrix method identifies resonances with a possibility of DEA formation. • Resonance detected at 1.88 eV is associated with Cl{sub 2}O{sup −} anion formation. - Abstract: Scattering dynamics of dichlorine monoxide (Cl{sub 2}O) molecule by electron impact is investigated as a function of electron energy and scattering angle. Electron impact total cross sections for Cl{sub 2}O over an extensive range of impact energies from 0.1 to 2000 eV are reported in this article. Below the ionization threshold of the target, the ab initio R-matrix method and above this incident energy spherical complex optical potential formalism are used for cross section calculation. The total cross section obtained from both theories merges smoothly at the overlapping energy. The resonances obtained using DZP basis sets are located at 1.883, 3.592, 5.205 and 7.326, 8.206, 8.301, 8.452, 9.369 eV and that with 6-31G* basis sets are identified at 1.944, 3.566, 5.183, 5.261, 5.658, 8.738 and 9.187 eV with the possibility of negative ions formation. This is the first attempt to calculate the differential, and momentum transfer cross sections for Cl{sub 2}O molecule.

  13. Effect of hyperbaric oxygen therapy on whole blood cyanide concentrations in carbon monoxide intoxicated patients from fire accidents

    DEFF Research Database (Denmark)

    Lawson-Smith, Pia; Jansen, Erik C; Hilsted, Linda

    2010-01-01

    Hydrogen cyanide (HCN) and carbon monoxide (CO) may be important components of smoke from fire accidents. Accordingly, patients admitted to hospital from fire accidents may have been exposed to both HCN and CO. Cyanide (CN) intoxication results in cytotoxic hypoxia leading to organ dysfunction...... and animal experiments have shown that in rats exposed to CN intoxication, HBO can increase the concentration of CN in whole blood....

  14. Foucault, surveillance, and carbon monoxide testing within stop-smoking services.

    Science.gov (United States)

    Grant, Aimee; Ashton, Kathryn; Phillips, Rhiannon

    2015-07-01

    Health professionals have adopted proactive testing for early evidence of disease. Researchers have identified that this leads to enumerated understandings and shapes behavior in productive ways. Smoking-cessation advisors regularly test clients for carbon monoxide (CO), but client views of this had not previously been explored. We interviewed 23 clients of a United Kingdom-based stop-smoking service regarding their experiences of CO testing. The majority of participants were successful quitters. We used ATLAS.ti 7 as a data-management tool during structured qualitative analysis. Our findings reveal that clients believed the results of their CO tests. Many became enumerated in their understanding, and thus placed themselves in a hierarchy with other members of their group. Almost all clients found that knowing their CO test score was motivating. We conclude that additional research is needed to understand the experiences of CO testing among clients who do not quit. © The Author(s) 2014.

  15. UV-induced carbon monoxide emission from sand and living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2012-01-01

    The global burden of carbon monoxide, CO, is rather uncertain. In this paper we address the potential of UV-induced CO emission by terrestrial surfaces. Real-time measurements of [CO] were made with a cavity enhanced laser connected in closed loop to either an ecosystem chamber or a leaf scale...... chamber. Sand and leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation and the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature, indicating an abiotic process. The emission of CO...... in response to the UV-component of natural solar radiation was also evident at the ecosystem scale. When scaled to the global level, the UV-induced emission of CO by the major types of terrestrial surfaces, living leaves and soil (here represented by sand), amounts up to 28 Tg yr−1. This source has...

  16. An Unusual Cause of Supraventricular Tachycardia: Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Suat Zengin

    2014-03-01

    Full Text Available      Carbon monoxide (CO is a toxic gas produced by the incomplete combustion of carbon-containing compounds. Exposure to high concentrations of CO can be letha and is the most common cause of death from poisoning worldwide. Cardiac manifestations after exposure to CO, including myocardial ischemia, heart failure, and arrhythmias, have been reported. A 28-year-old a patient was admitted to our emergency department with altered consciousness as a consequence of acute domestic exposure to CO from a stove. His carboxyhemoglobin level was 39%. The oxygen treatment was started promptly, and therapeutic red cell exchange was performed. An electrocardiogram revealed supraventricular tachycardia (SVT, and an echocardiographic examination demonstrated normal cardiac functions. To the best of our knowledge, this study is the second to report a case of SVT attack due to acute CO intoxication. This paper discusses the management of this complication in patients poisoned with CO.

  17. Liquefaction of lignohemicellulosic waste by processing with carbon monoxide and water

    Energy Technology Data Exchange (ETDEWEB)

    El-Saied, H

    1977-09-01

    The liquefaction of lignohemicellulosic waste by processing with carbon monoxide and water for 10 minutes at 250/sup 0/-440/sup 0/C and 40 to 70 atm initial pressure in a rocking autoclave produced benzene-soluble heavy oil in yields up to 80%. High conversion and yields were favored by high thermal stress, short reaction times, and sufficient hydrogen to prevent radical recombination in the critical liquefaction stages. The addition of sodium or calcium hydroxide, sodium carbonate, iron oxide, etc. in small amounts gave good oil yields under less severe conditions. Lignins from rice straw, bagasse, and other grasses gave higher yields than the woody lignin obtained from cotton stalks. In products obtained by liquefying black liquor lignohemicellulose from an Eyptian rice straw pulping plant, the hydrogen-carbon atomic ratio was 1.0 to 1.3:1.

  18. TEHRAN AIR POLLUTANTS PREDICTION BASED ON RANDOM FOREST FEATURE SELECTION METHOD

    Directory of Open Access Journals (Sweden)

    A. Shamsoddini

    2017-09-01

    Full Text Available Air pollution as one of the most serious forms of environmental pollutions poses huge threat to human life. Air pollution leads to environmental instability, and has harmful and undesirable effects on the environment. Modern prediction methods of the pollutant concentration are able to improve decision making and provide appropriate solutions. This study examines the performance of the Random Forest feature selection in combination with multiple-linear regression and Multilayer Perceptron Artificial Neural Networks methods, in order to achieve an efficient model to estimate carbon monoxide and nitrogen dioxide, sulfur dioxide and PM2.5 contents in the air. The results indicated that Artificial Neural Networks fed by the attributes selected by Random Forest feature selection method performed more accurate than other models for the modeling of all pollutants. The estimation accuracy of sulfur dioxide emissions was lower than the other air contaminants whereas the nitrogen dioxide was predicted more accurate than the other pollutants.

  19. Tehran Air Pollutants Prediction Based on Random Forest Feature Selection Method

    Science.gov (United States)

    Shamsoddini, A.; Aboodi, M. R.; Karami, J.

    2017-09-01

    Air pollution as one of the most serious forms of environmental pollutions poses huge threat to human life. Air pollution leads to environmental instability, and has harmful and undesirable effects on the environment. Modern prediction methods of the pollutant concentration are able to improve decision making and provide appropriate solutions. This study examines the performance of the Random Forest feature selection in combination with multiple-linear regression and Multilayer Perceptron Artificial Neural Networks methods, in order to achieve an efficient model to estimate carbon monoxide and nitrogen dioxide, sulfur dioxide and PM2.5 contents in the air. The results indicated that Artificial Neural Networks fed by the attributes selected by Random Forest feature selection method performed more accurate than other models for the modeling of all pollutants. The estimation accuracy of sulfur dioxide emissions was lower than the other air contaminants whereas the nitrogen dioxide was predicted more accurate than the other pollutants.

  20. Carbon monoxide poisoning: a five year review at Tan Tock Seng Hospital, Singapore.

    Science.gov (United States)

    Handa, P K; Tai, D Y H

    2005-11-01

    Carbon monoxide poisoning (COP) is one of the leading causes of death from poisoning worldwide. There is no published study of COP in Singapore so far. All patients admitted with the diagnosis of COP to Tan Tock Seng Hospital (TTSH) over 5 years from 1999 to 2003 were retrospectively reviewed. The diagnosis was based on a history of potential exposure to carbon monoxide (CO) and elevated levels of carboxyhaemoglobin (COHb). The causes, demographic data, clinical presentations, management and complications were analysed. There were 12 patients with COP. Their average age was 38.9 (+/-11.8) years, with a male-to-female ratio of 3:1. Accidental COP (58.3%) was more common than intentional COP (41.7%). The most common cause of accidental COP was smoke inhalation from a faulty vehicle. Gas stove was the most preferred source for intentional poisoning. Presenting features were headache (83.3%), confusion (83.3%), coma (12.7%) and agitation (8.3%). The mean COHb level on admission was 35.9% (+/-13.6). All were treated with 100% oxygen. All the patients achieved normal levels of COHb within 24 hours of admission. Two (16.7%) required intubation for airway protection as they were comatose on arrival, of which 1 presented with very high level of COHb (48.1%) and was the only patient to be treated with hyperbaric oxygen. Acute complications were globus pallidus infarction (16.6%), acute respiratory distress syndrome (8.3%) and myocardial ischaemia (8.3%). Most of the patients (91.7%) were discharged well from the hospital. One patient developed parkinsonism after a follow-up of 2 years. There were no deaths. COP is relatively uncommon in Singapore. It has a low rate of short- and long-term complications.

  1. Evaluation of Predicted and Observed Data on Biotransformation of Twenty-Nine Trace Organic Chemicals

    KAUST Repository

    Bertolini, Maria

    2011-07-01

    Trace organic chemicals present in household products, pesticides, pharmaceuticals and personal care products may have adverse ecotoxicological effects once they are released to the environment. These chemicals are usually transported with the sewage to wastewater treatment facilities, where they might be attenuated depending on the degree of treatment applied prior to discharge to receiving streams. This study evaluates the removal performance of 29 trace organic compounds during two different activated sludge treatment systems. Predominant attenuation processes such as biotransformation and sorption for the target compounds were identified. Biotransformation rate constants determined in this study were used to assess removal of compounds from other treatment plants with similar operational conditions, using data gathered from the literature. The commercial software Catalogic was applied to predict environmental fate of chemicals. The software program consisted of four models able to simulate molecular transformations and to generate degradation trees. In order to assess the accuracy of this program in predicting biotransformation, one biodegradation model is used to contrast predicted degradation pathway with metabolic pathways reported in the literature. The predicted outcome was correct for more than 40 percent of the 29 targeted substances, while 38 percent of the chemicals exhibited some degree of lower agreement between predicted and observed pathways. Percent removal data determined for the two treatment facilities was compared with transformation probability output from Catalogic. About 80 percent of the 29 compounds exhibited a good correlation between probability of transformation of the parent compound and percent removal data from the two treatment plants (R2 = 0.82 and 0.9). Based upon findings for 29 trace organic chemicals regarding removal during activated sludge treatment, attacked fragments present in their structures, predicted data from

  2. Sensor Data Fusion for Accurate Cloud Presence Prediction Using Dempster-Shafer Evidence Theory

    Directory of Open Access Journals (Sweden)

    Jesse S. Jin

    2010-10-01

    Full Text Available Sensor data fusion technology can be used to best extract useful information from multiple sensor observations. It has been widely applied in various applications such as target tracking, surveillance, robot navigation, signal and image processing. This paper introduces a novel data fusion approach in a multiple radiation sensor environment using Dempster-Shafer evidence theory. The methodology is used to predict cloud presence based on the inputs of radiation sensors. Different radiation data have been used for the cloud prediction. The potential application areas of the algorithm include renewable power for virtual power station where the prediction of cloud presence is the most challenging issue for its photovoltaic output. The algorithm is validated by comparing the predicted cloud presence with the corresponding sunshine occurrence data that were recorded as the benchmark. Our experiments have indicated that comparing to the approaches using individual sensors, the proposed data fusion approach can increase correct rate of cloud prediction by ten percent, and decrease unknown rate of cloud prediction by twenty three percent.

  3. EnviroAtlas - Cleveland, OH - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  4. EnviroAtlas - Austin, TX - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  5. EnviroAtlas - Portland, ME - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  6. EnviroAtlas - Woodbine, IA - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  7. EnviroAtlas - Milwaukee, WI - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  8. EnviroAtlas - Tampa, FL - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  9. EnviroAtlas - Pittsburgh, PA - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  10. EnviroAtlas - Phoenix, AZ - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  11. EnviroAtlas - Durham, NC - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  12. EnviroAtlas - Portland, OR - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  13. EnviroAtlas - Paterson, NJ - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  14. EnviroAtlas - Memphis, TN - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  15. EnviroAtlas - Fresno, CA - Estimated Percent Tree Cover Along Walkable Roads

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  16. EnviroAtlas Estimated Percent Tree Cover Along Walkable Roads Web Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates tree cover along walkable roads. The road width is estimated for each road and percent tree cover is calculated in a 8.5 meter...

  17. Amazing 7-day, super-simple, scripted guide to teaching or learning percents

    CERN Document Server

    Hernandez, Lisa

    2014-01-01

    Welcome to The Amazing 7-Day, Super-Simple, Scripted Guide to Teaching or Learning Percents. I have attempted to do just what the title says: make learning percents super simple. I have also attempted to make it fun and even ear-catching. The reason for this is not that I am a frustrated stand-up comic, but because in my fourteen years of teaching the subject, I have come to realize that my jokes, even the bad ones, have a crazy way of sticking in my students' heads. And should I use a joke (even a bad one) repetitively, the associations become embedded in their brains, many times to their cha

  18. Emphysema predicts hospitalisation and incident airflow obstruction among older smokers: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    David A McAllister

    Full Text Available Emphysema on CT is common in older smokers. We hypothesised that emphysema on CT predicts acute episodes of care for chronic lower respiratory disease among older smokers.Participants in a lung cancer screening study age ≥ 60 years were recruited into a prospective cohort study in 2001-02. Two radiologists independently visually assessed the severity of emphysema as absent, mild, moderate or severe. Percent emphysema was defined as the proportion of voxels ≤ -910 Hounsfield Units. Participants completed a median of 5 visits over a median of 6 years of follow-up. The primary outcome was hospitalization, emergency room or urgent office visit for chronic lower respiratory disease. Spirometry was performed following ATS/ERS guidelines. Airflow obstruction was defined as FEV1/FVC ratio <0.70 and FEV1<80% predicted.Of 521 participants, 4% had moderate or severe emphysema, which was associated with acute episodes of care (rate ratio 1.89; 95% CI: 1.01-3.52 adjusting for age, sex and race/ethnicity, as was percent emphysema, with similar associations for hospitalisation. Emphysema on visual assessment also predicted incident airflow obstruction (HR 5.14; 95% CI 2.19-21.1.Visually assessed emphysema and percent emphysema on CT predicted acute episodes of care for chronic lower respiratory disease, with the former predicting incident airflow obstruction among older smokers.

  19. Effect of serum testosterone and percent tumor volume on extra-prostatic extension and biochemical recurrence after laparoscopic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Eu Chang Hwang

    2016-01-01

    Full Text Available Several studies have revealed that the preoperative serum testosterone and percent tumor volume (PTV predict extra-prostatic extension (EPE and biochemical recurrence (BCR after radical prostatectomy. This study investigated the prognostic significance of serum testosterone and PTV in relation to EPE and BCR after laparoscopic radical prostatectomy (LRP. We reviewed 520 patients who underwent LRP between 2004 and 2012. PTV was determined as the sum of all visually estimated tumor foci in every section. BCR was defined as two consecutive increases in the postoperative prostate-specific antigen (PSA >0.2 ng ml−1 . The threshold for serum total testosterone was 3.0 ng ml−1 . Multivariate logistic regression was used to define the effect of variables on the risk of EPE and BCR. A low serum testosterone (<3.0 ng ml−1 was associated with a high serum PSA, Gleason score, positive core percentage of the prostate biopsy, PTV, and all pathological variables. On multivariate analysis, similar to previous studies, the serum PSA, biopsy positive core percentage, Gleason score, and pathological variables predicted EPE and BCR. In addition, low serum testosterone (<3.0 ng ml−1 , adjusted OR, 8.52; 95% CI, 5.04-14.4, P= 0.001 predicted EPE and PTV (adjusted OR, 1.02; 95% CI, 1.01-1.05, P= 0.046 predicted BCR. In addition to previous predictors of EPE and BCR, low serum testosterone and PTV are valuable predictors of EPE and BCR after LRP.

  20. Cull sow knife-separable lean content evaluation at harvest and lean mass content prediction equation development.

    Science.gov (United States)

    Abell, Caitlyn E; Stalder, Kenneth J; Hendricks, Haven B; Fitzgerald, Robert F

    2012-07-01

    The objectives of this study were to develop a prediction equation for carcass knife-separable lean within and across USDA cull sow market weight classes (MWC) and to determine carcass and individual primal cut knife separable lean content from cull sows. There were significant percent lean and fat differences in the primal cuts across USDA MWC. The two lighter USDA MWC had a greater percent carcass lean and lower percent fat compared to the two heavier MWC. In general, hot carcass weight explained the majority of carcass lean variation. Additionally, backfat was a significant variation source when predicting cull sow carcass lean. The findings support using a single lean prediction equation across MWC to assist processors when making cull sow purchasing decisions and determine the mix of animals from various USDA MWC that will meet their needs when making pork products with defined lean:fat content. Copyright © 2012 Elsevier Ltd. All rights reserved.