WorldWideScience

Sample records for monoxide electronic resource

  1. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    Science.gov (United States)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  2. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias

    2013-09-15

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  3. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    International Nuclear Information System (INIS)

    Stollenwerk, Tobias

    2013-09-01

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  4. The Range of 1-3 keV Electrons in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Oehlenschlæger, M.; Andersen, H.H.; Schou, Jørgen

    1985-01-01

    The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than that in n......The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than...

  5. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Community Outreach Resource Center Toy Recall Statistics CO Poster Contest Pool Safely Business & Manufacturing Business & Manufacturing Business ... Featured Resources CPSC announces winners of carbon monoxide poster contest Video View the blog Clues You Can ...

  6. In situ disordering of monoclinic titanium monoxide Ti5O5 studied by transmission electron microscope TEM.

    Science.gov (United States)

    Rempel, А А; Van Renterghem, W; Valeeva, А А; Verwerft, M; Van den Berghe, S

    2017-09-07

    The superlattice and domain structures exhibited by ordered titanium monoxide Ti 5 O 5 are disrupted by low energy electron beam irradiation. The effect is attributed to the disordering of the oxygen and titanium sublattices. This disordering is caused by the displacement of both oxygen and titanium atoms by the incident electrons and results in a phase transformation of the monoclinic phase Ti 5 O 5 into cubic B1 titanium monoxide. In order to determine the energies required for the displacement of titanium or oxygen atoms, i.e. threshold displacement energies, a systematic study of the disappearance of superstructure reflections with increasing electron energy and electron bombardment dose has been performed in situ in a transmission electron microscope (TEM). An incident electron energy threshold between 120 and 140 keV has been observed. This threshold can be ascribed to the displacements of titanium atoms with 4 as well as with 5 oxygen atoms as nearest neighbors. The displacement threshold energy of titanium atoms in Ti 5 O 5 corresponding with the observed incident electron threshold energy lies between 6.0 and 7.5 eV. This surprisingly low value can be explained by the presence of either one or two vacant oxygen lattice sites in the nearest neighbors of all titanium atoms.

  7. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide ... Related Links Recalls Safety Education Regulations, Laws & Standards Research & Statistics Business & Manufacturing Small Business Resources OnSafety Blogs ...

  8. Metallic and insulating 3d transition-element monoxides and their stability

    International Nuclear Information System (INIS)

    Johansson, H.B.

    1977-01-01

    The binding properties of the 3d monoxides are studied in detail, and it is shown that the metallic character of TiO and VO is directly reflected in their heat of formation. The same holds true for NbO. From a stability analysis of the 3d monoxides versus decomposition, it is found that TiO, VO, and FeO are close to an instability. Further, it can be concluded that both ScO and CrO must be very near existence. The general occurrence of transition-metal monoxides is shown to be directly correlated with ionic properties of the transition elements. An investigation of the absorption edge in the 3d monoxides is also undertaken. The importance of the crystal-field splitting is noticed, and it is shown that the heat of formation of the monoxides can be used to derive the crystal-field parameter Δ. The change from a delocalized to a localized behavior of the d electrons in the 3d monoxides is compared with a similar change of the f electrons in the actinides. Some similarities between these two series of materials are pointed out

  9. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  10. On the composition of nonstoichiometric europium monoxide

    International Nuclear Information System (INIS)

    Ignat'eva, N.I.

    1990-01-01

    Consideration is given to results of of investigation into chemical composition, homogeneity region, type of disordering of nonstoichiometric europium monoxide. Precision methods of X-ray diffraction, electron-microscopic, atomic-absorption chemical analysis were used. It is shown that lattice volume reduces with increase of oxygen content in the oxide. For monocrystal of EuO 1.01 composition a=5.146 A. All samples of europium monoxide are characterized by low conductivity. Conductivity value changes by two orders (from 10 -8 to 10 -6 Θ -1 ·cm -1 ) when passing from the sample of stoichiometric composition to maximally disordered one. The disordering is considered according to the type of charged cation vacancies, leading to occurrence of equivalent number of electron defects of positive holes. 4 refs.; 1 tab

  11. Development of an enzymatic sensor for carbon monoxide

    International Nuclear Information System (INIS)

    Hurtado, Clara; Gomez, Diana; Larmat, Fernando; Torres, Walter; Cuervo, Raul; Bravo, Enrique; Benitez, Neyla

    2003-01-01

    The detection and the pursuit of gases that contribute in the increase of the atmospheric contamination are a necessity, for what the electrochemical sensors have potential industrial applications for the control of the quality of the air. The development of amperometric sensor based on enzymes offers advantages, since the use of the biological component provides him high selectivity due to the great specificity of the substrate of the enzyme. The monoxide of carbon (CO) it is a polluting, poisonous gas, taken place during the incomplete combustion of organic materials (natural gas, petroleum, gasoline, coal and vegetable material). The determination of monoxide of carbon (CO) it can be reached by electrochemical mediums using the methylene blue like the electronic mediator for the enzyme monoxide of carbon oxidase (COx)

  12. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Safety Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as CO, is called the " ...

  13. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    Science.gov (United States)

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  14. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Science.gov (United States)

    Kaminaga, Kenichi; Sei, Ryosuke; Hayashi, Kouichi; Happo, Naohisa; Tajiri, Hiroo; Oka, Daichi; Fukumura, Tomoteru; Hasegawa, Tetsuya

    Rare earth sesquioxides like Y2O3 are known as widegap insulators with the highly stable closed shell trivalent rare earth ions. On the other hand, rare earth monoxides such as YO have been recognized as gaseous phase, and only EuO and YbO were thermodynamically stable solid-phase rock salt monoxides. In this study, solid-phase rock salt yttrium monoxide, YO, was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO possesses unusual valence of Y2+ ([Kr] 4d1) . In contrast with Y2O3, YO was narrow gap semiconductor with dark-brown color. The electrical conductivity was tunable from 10-1 to 103 Ω-1 cm-1 by introducing oxygen vacancies as electron donor. Weak antilocalization behavior was observed indicating significant spin-orbit coupling owing to 4 d electron carrier. The absorption spectral shape implies the Mott-Hubbard insulator character of YO. Rare earth monoixdes will be new platform of functional oxides. This work was supported by JST-CREST, the Japan Society for the Promotion of Science (JSPS) with Grant-in-Aid for Scientific Research on Innovative Areas (Nos. 26105002 and 26105006), and Nanotechnology Platform (Project No.12024046) of MEXT, Japan.

  15. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, ... Install one and check its batteries regularly. View Information About CO Alarms Other CO Topics Safety Tips ...

  16. Carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The document identifies the main sources of carbon monoxide (CO) in the general outdoor atmosphere, describes methods of measuring and monitoring its concentration levels in the United Kingdom, and discusses the effects of carbon monoxide on human health. Following its review, the Panel has put forward a recommendation for an air quality standard for carbon monoxide in the United Kingdom of 10 ppm, measured as a running 8-hour average. The document includes tables and graphs of emissions of CO, in total and by emission source, and on the increase in blood levels of carboxyhaemoglobin with continuing exposure to CO. 11 refs., 4 figs., 4 tabs.

  17. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Kamal Mishra

    2016-01-01

    Full Text Available Introduction: Carbon monoxide is known as the silent killer, being colorless, odourless, and tasteless. Initially non-irritating, it is very difficult for people to detect Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply that prevents complete oxidation of carbon to C02. During World War II, Nazis used gas vans to kill an estimated over 700,000 prisoners by carbon monoxide poisoning. This method was also used in the gas chambers ofseveral death camps. The true number of incidents of carbon monoxide poisoning is unknown, since many non-lethal exposures go undetected From the available data, carbon monoxide poisoning is the most common cause of injury and death due to poisoning worldwide. Clinical features and management: The signs of carbon monoxide poisoning vary with concentration and length of exposure. Subtle cardiovascular or neurobehavioural effects occur at low concentration. The onset of chronic poisoning is usually insidious and easily mistaken for viral prodrome, depression, or gastroenteritis in children. The classic sign of carbon monoxide poisoning which is actually more often seen in the dead than the living is appearing red-cheeked and healthy. Cherry pink colour develops in nails, skin and mucosa. In acute poisoning, common abnormalities of posture and tone are cogwheel rigidity, opisthotonus, spasticity or flaccidity and seizures. Retinal haemorrhages and the classic cherry red skin colour are seldom seen. Different people andpopulations may have different carbon monoxide tolerance levels. On average, exposures at 100ppm or greater is dangerous to human health. Treatment and prevention: The mainstay of treatment is 100% oxygen administration until the COHb level is normal When the patient is stable enough to be transported, hyperbaric oxygen (HBOT should be considered This treatment is safe and well tolerated Public education about the danger of carbon monoxide, with

  18. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  19. Carbon Monoxide Safety

    Science.gov (United States)

    ... with the Media Fire Protection Technology Carbon monoxide safety outreach materials Keep your community informed about the ... KB | Spanish PDF 592 KB Handout: carbon monoxide safety Download this handout and add your organization's logo ...

  20. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  1. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... main content Languages 简体中文 English Bahasa Indonesia 한국어 Español ภาษาไทย Tiếng Việt Text Size: Decrease Font Increase ... Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as ...

  2. Carbon monoxide poisoning

    Science.gov (United States)

    ... Animals can also be poisoned by carbon monoxide. People who have pets at home may notice that their animals become ... or unresponsive from carbon monoxide exposure. Often the pets will ... these conditions. This can lead to a delay in getting help.

  3. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  4. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  5. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  6. Electronic and structural properties of micro-and nanometre-sized crystalline copper monoxide ceramics investigated by positron annihilation

    International Nuclear Information System (INIS)

    Druzhkov, A.P.; Gizhevskii, B.A.; Arbuzov, V.L.; Shalnov, K.V.; Naumov, S.V.; Perminov, D.A.; Kozlov, E.A.

    2002-01-01

    Electronic and structural properties of copper monoxide (CuO) sintered as a common ceramic and nanoceramic are studied by positron annihilation spectroscopy. A CuO nanoceramic with crystallite size ranging from 15 to 90 nm was prepared from a common one by shock-wave loading. It is found that the momentum distribution of valence electrons in CuO is shifted, as compared with metallic copper, towards higher momentum values. This result is related to the effect of the Cu 3d-O 2p hybridization in the Cu-O ionic covalent bond formation. It is found that open volumes, identified mainly as small agglomerates of oxygen vacancies, appear at the nanoceramic crystallite interfaces. The degree of the Cu-O bond covalency decreases locally at the crystallite interfaces because of an oxygen deficit. The nanocrystalline state in CuO is shown to be thermally stable up to 700 K. (author)

  7. Electronic and structural properties of micro-and nanometre-sized crystalline copper monoxide ceramics investigated by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Druzhkov, A.P. [Institute of Metal Physics, Ural Branch Russian Academy of Sciences, Ekaterinburg (Russian Federation)]. E-mail: druzhkov@imp.uran.ru; Gizhevskii, B.A.; Arbuzov, V.L.; Shalnov, K.V.; Naumov, S.V.; Perminov, D.A. [Institute of Metal Physics, Ural Branch Russian Academy of Sciences, Ekaterinburg (Russian Federation); Kozlov, E.A. [All-Russian R and D Institute of Technical Physics, Snezhinsk (Russian Federation)

    2002-09-02

    Electronic and structural properties of copper monoxide (CuO) sintered as a common ceramic and nanoceramic are studied by positron annihilation spectroscopy. A CuO nanoceramic with crystallite size ranging from 15 to 90 nm was prepared from a common one by shock-wave loading. It is found that the momentum distribution of valence electrons in CuO is shifted, as compared with metallic copper, towards higher momentum values. This result is related to the effect of the Cu 3d-O 2p hybridization in the Cu-O ionic covalent bond formation. It is found that open volumes, identified mainly as small agglomerates of oxygen vacancies, appear at the nanoceramic crystallite interfaces. The degree of the Cu-O bond covalency decreases locally at the crystallite interfaces because of an oxygen deficit. The nanocrystalline state in CuO is shown to be thermally stable up to 700 K. (author)

  8. Occult carbon monoxide poisoning.

    Science.gov (United States)

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  9. Highly n-Type Titanium Oxide as an Electronically Active Support for Platinum in the Catalytic Oxidation of Carbon Monoxide

    KAUST Repository

    Baker, L. Robert

    2011-08-18

    The role of the oxide-metal interface in determining the activity and selectivity of chemical reactions catalyzed by metal particles on an oxide support is an important topic in science and industry. A proposed mechanism for this strong metal-support interaction is electronic activation of surface adsorbates by charge carriers. Motivated by the goal of using electronic activation to drive nonthermal chemistry, we investigated the ability of the oxide support to mediate charge transfer. We report an approximately 2-fold increase in the turnover rate of catalytic carbon monoxide oxidation on platinum nanoparticles supported on stoichiometric titanium dioxide (TiO2) when the TiO2 is made highly n-type by fluorine (F) doping. However, for nonstoichiometric titanium oxide (TiOX<2) the effect of F on the turnover rate is negligible. Studies of the titanium oxide electronic structure show that the energy of free electrons in the oxide determines the rate of reaction. These results suggest that highly n-type TiO2 electronically activates adsorbed oxygen (O) by electron spillover to form an active O- intermediate. © 2011 American Chemical Society.

  10. Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Alisa Wray

    2016-07-01

    Full Text Available Audience: This oral boards case is appropriate for all emergency medicine learners (residents, interns, and medical students. Introduction: Carbon monoxide (CO is a colorless and odorless gas that typically results from combustion. It binds hemoglobin, dissociating oxygen, causing headache, weakness, confusion and possible seizure or coma. Pulse oxygen levels may be falsely elevated. Practitioners should maintain a high index of suspicion for carbon monoxide poisoning. If caught early CO poisoning is reversible with oxygen or hyperbaric oxygen therapy. Objectives: The learner will assess a patient with altered mental status and weakness, ultimately identifying that the patient has carbon monoxide poisoning. The learner will treat the patient with oxygen and admit/transfer the patient for hyperbaric oxygenation. Method: Oral boards case

  11. 0.1–2000 eV electron impact cross sections for dichlorine monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Goswami, Biplab; Gupta, Dhanoj; Antony, Bobby, E-mail: bka.ism@gmail.com

    2014-03-01

    Highlights: • Quantum mechanical models were used to find TCS for e-Cl{sub 2}O from 0.1 to 2000 eV. • R-matrix method at low energies (<13 eV) and SCOP at high energies (13–2000 eV). • Besides TCS, DCS, excitation cross section and momentum transfer CS also predicted. • R-matrix method identifies resonances with a possibility of DEA formation. • Resonance detected at 1.88 eV is associated with Cl{sub 2}O{sup −} anion formation. - Abstract: Scattering dynamics of dichlorine monoxide (Cl{sub 2}O) molecule by electron impact is investigated as a function of electron energy and scattering angle. Electron impact total cross sections for Cl{sub 2}O over an extensive range of impact energies from 0.1 to 2000 eV are reported in this article. Below the ionization threshold of the target, the ab initio R-matrix method and above this incident energy spherical complex optical potential formalism are used for cross section calculation. The total cross section obtained from both theories merges smoothly at the overlapping energy. The resonances obtained using DZP basis sets are located at 1.883, 3.592, 5.205 and 7.326, 8.206, 8.301, 8.452, 9.369 eV and that with 6-31G* basis sets are identified at 1.944, 3.566, 5.183, 5.261, 5.658, 8.738 and 9.187 eV with the possibility of negative ions formation. This is the first attempt to calculate the differential, and momentum transfer cross sections for Cl{sub 2}O molecule.

  12. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  13. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  14. Inhibition of photosynthesis by carbon monoxide and suspension of the carbon monoxide inhibition by light

    Energy Technology Data Exchange (ETDEWEB)

    Gewitz, H S; Voelker, W

    1963-08-01

    The experimental subject was the autotroph Chlorella pyrenoidosa. It was found that growth conditions determine whether the alga is inhibited by carbon monoxide or not. Respiration and photosynthesis are inhibited by carbon monoxide if the cells have grown rapidly under high light intensities. The inhibition of respiration and photosynthesis found in such cells is completely reversible. The inhibition depends not only on carbon monoxide pressure, but also on the oxygen pressure prevailing at the same time. 5 references, 1 figure, 3 tables.

  15. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  16. Electronic properties of rocksalt copper monoxide: a proxy structure for high temperature superconductivity

    International Nuclear Information System (INIS)

    Grant, Paul M

    2008-01-01

    Cubic rocksalt copper monoxide, in contrast to its lighter transition metal neighbours, does not exist in nature nor has it yet been successfully synthesized. Nonetheless, its numerical study as a structurally much simpler proxy for the layered cuprate perovskites may prove useful in probing the source of high temperature superconductivity in the latter family of compounds. Here we report such a study employing density functional theory (DFT) abetted by the local density approximation including cation on-site Hubbard interactions (LDA+U). Rather surprisingly, we find that unlike oxides of the light transition metals, cubic CuO remains metallic for all physically reasonable values of U and does not result in a Mott- Hubbard induced charge transfer insulator as might be expected, and, in fact, displays a Fermi surface with clearly nesting tendencies. Preliminary calculations of the net dimensionless electron-phonon coupling constant, λ, yield values in the range 0.6 - 0.7 similar to those found for the superconducting fullerenes and magnesium diboride. On the other hand, we do find as we gradually introduce a tetragonal distortion away from pure cubic symmetry that a charge- transfer insulator emerges for values of U ∼ 5 eV and c/a ∼ 1.3 in agreement with recent experimental data on forced-epitaxial growth of 2-4 ML thick films of tetragonal rocksalt CuO. We preliminarily conclude from these computational studies that high temperature superconductivity in the copper oxide compounds is at least initially mediated by Jahn-Teller driven electron-phonon coupling as originally suggested by Bednorz and Mueller.

  17. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  18. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  19. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  20. use of electronic resources by graduate students of the department

    African Journals Online (AJOL)

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  1. Convergence of quasiparticle self-consistent GW calculations of transition metal monoxides

    OpenAIRE

    Das, Suvadip; Coulter, John E.; Manousakis, Efstratios

    2014-01-01

    Finding an accurate ab initio approach for calculating the electronic properties of transition metal oxides has been a problem for several decades. In this paper, we investigate the electronic structure of the transition metal monoxides MnO, CoO, and NiO in their undistorted rock-salt structure within a fully iterated quasiparticle self-consistent GW (QPscGW) scheme. We study the convergence of the QPscGW method, i.e., how the quasiparticle energy eigenvalues and wavefunctions converge as a f...

  2. Occult Carbon Monoxide Poisoning

    OpenAIRE

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms ...

  3. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  4. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  5. Calculated Specific Volumes and Magnetic Moments of the 3d Transition Metal Monoxides

    DEFF Research Database (Denmark)

    Skriver, Hans Lomholt; Andersen, O. K.; Johansson, B.

    1980-01-01

    We have performed self-consistent, spin-polarized band structure calculations as a function of the lattice spacing for the 3d metal monoxides in order to obtain the equilibrium lattice constants. The calculated binding from the 3d electrons and the occurrence of antiferromagnetism account...

  6. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  7. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-01-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem. Images Figure 1 Figure 2 PMID:10379009

  8. An unusual case of carbon monoxide poisoning.

    Science.gov (United States)

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-07-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem.

  9. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  10. First principles description of the insulator-metal transition in europium monoxide

    KAUST Repository

    Wang, Hao

    2012-02-01

    Europium monoxide, EuO, is a ferromagnetic insulator. Its electronic structure under pressure and doping is investigated by means of density functional theory. We employ spin polarized electronic structure calculations including onsite electron-electron interaction for the localized Eu 4f and 5d electrons. Our results show that under pressure the ferromagnetism is stable, both for hydrostatic and uniaxial pressure, while the compound undergoes an insulator-metal transition. The insulator-metal transition in O deficient and Gd doped EuO is reproduced for an impurity concentration of 6.25%. A 10 monolayer thick EuO(1 0 0) thin film is predicted to be an insulator with a narrow band gap of 0.08 eV. © 2011 Elsevier B.V. All rights reserved.

  11. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  12. An operando FTIR spectroscopic and kinetic study of carbon monoxide pressure influence on rhodium-catalyzed olefin hydroformylation.

    Science.gov (United States)

    Kubis, Christoph; Sawall, Mathias; Block, Axel; Neymeyr, Klaus; Ludwig, Ralf; Börner, Armin; Selent, Detlef

    2014-09-08

    The influence of carbon monoxide concentration on the kinetics of the hydroformylation of 3,3-dimethyl-1-butene with a phosphite-modified rhodium catalyst has been studied for the pressure range p(CO)=0.20-3.83 MPa. Highly resolved time-dependent concentration profiles of the organometallic intermediates were derived from IR spectroscopic data collected in situ for the entire olefin-conversion range. The dynamics of the catalyst and organic components are described by enzyme-type kinetics with competitive and uncompetitive inhibition reactions involving carbon monoxide taken into account. Saturation of the alkyl-rhodium intermediates with carbon monoxide as a cosubstrate occurs between 1.5 and 2 MPa of carbon monoxide pressure, which brings about a convergence of aldehyde regioselectivity. Hydrogenolysis of the acyl intermediate is fast at 30 °C and low pressure of p(CO)=0.2 MPa, but is of minus first order with respect to the solution concentration of carbon monoxide. Resting 18-electron hydrido and acyl complexes that correspond to early and late rate-determining states, respectively, coexist as long as the conversion of the substrate is not complete. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be safely...

  14. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Directory of Open Access Journals (Sweden)

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  15. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  16. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Directory of Open Access Journals (Sweden)

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  17. Preservation and conservation of electronic information resources of ...

    African Journals Online (AJOL)

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  18. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  19. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  20. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  1. Thermal Reactions in Mixtures of Micron-sized Silicon Monoxide and Titanium Monoxide - Redox Paths Overcoming Passivation Shells.

    Czech Academy of Sciences Publication Activity Database

    Jandová, Věra; Pokorná, Dana; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, Petra; Pola, Josef

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 R&D Projects: GA TA ČR TA04010169 Institutional support: RVO:67985858 Keywords : silicon monoxide * titanium monoxide * hifh-temperature Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 1.369, year: 2016

  2. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  3. Thermal reactions in mixtures of micron-sized silicon monoxide and titanium monoxide: redox paths overcoming passivation shells

    Czech Academy of Sciences Publication Activity Database

    Jandová, V.; Pokorná, D.; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, P.; Pola, J.

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 Institutional support: RVO:61388980 Keywords : Silicon monoxide * Titanium monoxide * High-temperature * Oxygen-transfer reactions * Titanium suboxides * Titanium silicide * Methylene blue depletion Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.369, year: 2016

  4. Carbon monoxide: The 21st century poison that goes unnoticed

    International Nuclear Information System (INIS)

    Hoskins, J.A.

    1999-01-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described

  5. Carbon monoxide: The 21st century poison that goes unnoticed

    Energy Technology Data Exchange (ETDEWEB)

    Hoskins, J.A. [Reigate, Surrey (United Kingdom)

    1999-07-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described.

  6. Vacancy distribution in nonstoichiometric vanadium monoxide

    International Nuclear Information System (INIS)

    Gusev, A.I.; Davydov, D.A.; Valeeva, A.A.

    2011-01-01

    Graphical abstract: Display Omitted Research highlights: → A certain fraction of vanadium atoms in disordered cubic vanadium monoxide VO y and ordered tetragonal phase V 52 O 64 is located in tetrahedral positions of a basic cubic lattice. → These positions are never occupied by any atoms in other strongly nonstoichiometric carbides, nitrides and oxides. → Both disordered and ordered structures of vanadium monoxide are characterized by the presence of short-range order of displacements in the oxygen sublattice and short-range order of substitution in the metal sublattice. → The short-range order of displacement is caused by the local displacements of O atoms from V (t) atoms occupying tetrahedral positions. The short-range order of substitution appears because V (t) atoms in the tetrahedral positions are always in the environment of four vacancies □ of the vanadium sublattice. - Abstract: Structural vacancy distribution in the crystal lattice of the tetragonal V 52 O 64 superstructure which is formed on the basis of disordered superstoichiometric cubic vanadium monoxide VO y ≡V x O z is experimentally determined and the presence of significant local atomic displacements and large local microstrains in a crystal lattice of real ordered phase is established. It is shown that the relaxation of local microstrains takes place owing to the basic disordered cubic phase grain refinement and a formation of ordered phase domains. The ordered phase domains grow in the direction from the boundaries to the centre of grains of the disordered basic cubic phase. Isothermal evolution at 970 K of the average domain size in ordered VO 1.29 vanadium monoxide is established. It is shown that the short-range order presents in a metal sublattice of disordered cubic VO y vanadium monoxide. The character of the short-range order is such that vanadium atoms occupying tetrahedral positions are in the environment of four vacant sites of the vanadium sublattice. This means that the

  7. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  8. Ferromagnetic semiconductor-metal transition in heterostructures of europium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Stollenwerk, Tobias; Kroha, Johann [Physikalisches Institut der Universitaet Bonn (Germany)

    2012-07-01

    Experiments on thin films of electron doped europium monoxide show a simultaneous ferromagnetic semiconductor-metal transition which goes along with a huge drop in resistivity over several orders of magnitude. Therefore, this material is a very promising candidate for spintronics applications. We have developed a theory which correctly predicts the simultaneous phase transition in thin films of electron doped EuO and the increase of the Curie temperature T{sub C} with doping concentration. The origin of the increased T{sub C} lies in the enhanced RKKY interaction between the localized 4f moments of the Eu atoms. Therefore, the phase transition is controlled by the population of the conduction band. We investigate the influence of film thickness and interface effects on the population of the conduction band and on the magnetic and electronic properties of the EuO film.

  9. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  10. Enzymic oxidation of carbon monoxide. II

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, T

    1959-01-01

    An enzyme which catalyzes the oxidation of carbon monoxide into carbon dioxide was obtained in a cell free state from Desulfovibrio desulfuricans. The enzyme activity was assayed manometrically by measuring the rate of gas uptake under the atmosphere of carbon monoxide in the presence of benzyl-viologen as an oxidant. The optimum pH range was 7 to 8. The activity was slightly suppressed by illumination. The enzyme was more stable than hydrogenase or formate dehydrogenase against the heat treatment, suggesting that it is a different entity from these enzymes. In the absence of an added oxidant, the enzyme preparation produced hydrogen gas under the atmosphere of carbon monoxide. The phenomenon can be explained assuming the reductive decomposition of water. 17 references, 4 figures, 2 tables.

  11. Mixing ratios of carbon monoxide in the troposphere

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Steele, L.P. (Univ. of Colorado, Boulder (United States)); Tans, P.P. (NOAA, Boulder, CO (United States))

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  12. Bacterium oxidizing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kistner, A

    1953-01-01

    Present-day knowledge of the microbiological oxidation of carbon monoxide is based on doubtful observations and imperfect experimental procedures. By making use of shake cultures in contact with gas mixtures containing high concentrations of CO and by employing liquid enrichment media with a low content of organic matter and solid media of the same composition with not more than 1.2% agar, it proved possible to isolate a co-oxidizing bacterium of the genus hydrogenomonas from sewage sludge. For the first time irrefutable proof has been given of the oxidation of carbon monoxide by a pure culture of a bacterium, both in growing cultures and in resting cell suspensions. 12 references.

  13. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008

    International Nuclear Information System (INIS)

    Lefebvre, B.; Chabot, L.; Gratton, J.; Lacoursiere, D.

    2009-01-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  14. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  15. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ...

  16. Search of medical literature for indoor carbon monoxide exposure

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  17. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  18. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kaminaga, Kenichi; Sei, Ryosuke [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan); Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hayashi, Kouichi [Department of Environmental and Materials Engineering, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Happo, Naohisa [School of Information Sciences, Hiroshima City University, Hiroshima 731-3194 (Japan); Tajiri, Hiroo [Japan Synchrotron Radiation Research Institute (JASRI)/SPring-8, Sayo 679-5198 (Japan); Oka, Daichi; Fukumura, Tomoteru, E-mail: tomoteru.fukumura.e4@tohoku.ac.jp [Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hasegawa, Tetsuya [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan)

    2016-03-21

    Rare earth oxides are usually widegap insulators like Y{sub 2}O{sub 3} with closed shell trivalent rare earth ions. In this study, solid phase rock salt structure yttrium monoxide, YO, with unusual valence of Y{sup 2+} (4d{sup 1}) was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO has been recognized as gaseous phase in previous studies. In contrast with Y{sub 2}O{sub 3}, YO was dark-brown colored and narrow gap semiconductor. The tunable electrical conductivity ranging from 10{sup −1} to 10{sup 3} Ω{sup −1 }cm{sup −1} was attributed to the presence of oxygen vacancies serving as electron donor. Weak antilocalization behavior observed in magnetoresistance indicated significant role of spin-orbit coupling as a manifestation of 4d electron carrier.

  19. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  20. Delayed encephalopathy after acute carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet İbrahim Turan

    2014-03-01

    Full Text Available Carbon monoxide poisoning is a major cause of death following attempted suicide and accidental exposures. Although clinical presentation depends on the duration and the intensity of exposure, the assessment of the severity of intoxication is difficult. A small percentage of patients who show complete initial recovery may develop delayed neurological deficits. Delayed encephalopathy after acute carbon monoxide poisoning is a rare and poor prognosis neurologic disorders and there is no specific treatment. We present a case with early onset of delayed encephalopathy after acute carbon monoxide poisoning with typical cranial imaging findings in a child with atypical history and clinical presentation.

  1. First-Principles Investigations on Europium Monoxide

    KAUST Repository

    Wang, Hao

    2011-05-01

    Europium monoxide is both an insulator and a Heisenberg ferromagnet (Tc=69 K). In the present thesis, the author has investigated the electronic structure of different types of EuO by density functional theory. The on-site Coulomb interaction of the localized Eu 4f and 5d electrons, which is wrongly treated in the standard generalized gradient approximation method, is found to be crucial to obtain the correct insulating ground state as observed in experiments. Our results show that the ferromagnetism is stable under pressure, both hydrostatic and uniaxial. For both types of pressure an insulator-metal transition is demonstrated. Moreover, the experimentally observed insulator-metal transition in oxygen deficient and gadolinium-doped EuO is reproduced in our calculations for impurity concentrations of 6.25% and 25%. Furthermore, a 10- layer EuO thin film is theoretically predicted to be an insulator with a narrow band gap of around 0.08 eV, while the Si/EuO interface shows metallic properties with the Si and O 2p as well as Eu 5d bands crossing the Fermi level.

  2. An infrared spectroscopic study of the adsorption of carbon monoxide on silica-supported copper particles

    NARCIS (Netherlands)

    Jong, K.P. de; Geus, John W.; Joziasse, J.

    Infrared spectroscopy is used to study the adsorption of carbon monoxide (20°C; 0.1– 100 Torr) on copper-on-silica catalysts differently prepared and pretreated. As determined by electron microscopy and X-ray line broadening, the catalysts contain copper particles having sizes of 60 to 5000 Å

  3. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  4. Why and How to Measure the Use of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  5. The electric dipole moment of cobalt monoxide, CoO.

    Science.gov (United States)

    Zhuang, Xiujuan; Steimle, Timothy C

    2014-03-28

    A number of low-rotational lines of the E(4)Δ7/2 ← X(4)Δ7/2 (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h7/2, and the electron quadrupole parameter, eQq0, for the E(4)Δ7/2(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ(→)(el), for the X(4)Δ7/2 (υ = 0) and E(4)Δ7/2 (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F' = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F' = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  6. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Import Surveillance International Recall Guidance Civil and Criminal Penalties Federal Court Orders & ... 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 ...

  7. Iron monoxide photodissociation

    Science.gov (United States)

    Chestakov, D. A.; Parker, D. H.; Baklanov, A. V.

    2005-02-01

    The photodissociation of Fe56O was studied by means of the velocity map imaging technique. A molecular beam of iron atoms and iron monoxide molecules was created using an electrical discharge with an iron electrode in a supersonic expansion of molecular oxygen. The ground state iron atom Fe(D45) and FeO concentrations in the molecular beam have been estimated. The dissociation energy of the FeO XΔ5 ground electronic state was found to be D00(FeO )=4.18±0.01eV. The effective absorption cross section of FeO at 252.39nm (vac), leading to the Fe(D45)+O(P3) dissociation channel, is ˜1.2×10-18cm2. A (1+1) resonantly enhanced multiphoton ionization spectrum of Fe56O in the region 39550-39580 cm-1 with rotational structure has been observed, but not assigned. Angular distributions of Fe(D45) and Fe(D35) products for the channel FeO →Fe(D4,35)+O(P3) have been measured at several points in the 210-260nm laser light wavelength region. The anisotropy parameter varies strongly with wavelength for both channels.

  8. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  9. Hydrogenation of carbon monoxide over supported palladium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K.; Hashimoto, H.; Kunugi, T.

    1978-03-01

    An alumina-supported 2% palladium catalyst had higher activity for carbon monoxide hydrogenation than a silica-supported 2% palladium catalyst, at 250/sup 0/-400/sup 0/C and 1 atm. The addition of lanthanum oxide or thorium oxide, but not of potassium oxide, to the silica-supported catalyst increased the conversion at 350/sup 0/C from 1.1% to 81.0% with a selectivity of 56.1% for methane, 1.4% for C/sub 2/ compounds, 0.1% for C/sub 3/ compounds, and 42.5% for carbon dioxide. Temperature-programed desorption of carbon monoxide in a hydrogen stream showed that of two desorption peaks observed for carbon monoxide, the one at higher temperature corresponded to the carbon monoxide species which hydrogenates to methane and that the area of this peak increased with increasing thorium content of the catalyst. Graphs, tables, and 12 references.

  10. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Science.gov (United States)

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  11. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao

    2017-04-12

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  12. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    KAUST Repository

    Wang, Yao; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  13. Carbon Monoxide Nonattainment Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies areas in the U.S. where air pollution levels have not met the National Ambient Air Quality Standards (NAAQS) for Carbon Monoxide and have...

  14. Development a low-cost carbon monoxide sensor using homemade CW-DFB QCL and board-level electronics

    Science.gov (United States)

    Dang, Jingmin; Yu, Haiye; Zheng, Chuantao; Wang, Lijun; Sui, Yuanyuan; Wang, Yiding

    2018-05-01

    A mid-infrared sensor was demonstrated for the detection of carbon monoxide (CO) at trace level. In order to reduce cost, a homemade continuous-wave mode distributed feedback quantum cascade laser (CW-DFB QCL), a mini gas cell with 1.6-m optical length, and some self-development electronic modules were adopted as excitation source, absorption pool, and signal controlling and processing tool, respectively. Wavelength modulation spectroscopy (WMS) and phase sensitive detection (PSD) techniques as well as wavelet filtering software algorithm were used to reduce the influence of light source fluctuation and system noise and to improve measurement precision and sensitivity. Under the selected P(11) absorption line located at 2099.083 cm-1, a limit of detection (LoD) of 26 parts per billion by volume (ppbv) at atmospheric pressure was achieved with a 1-s acquisition time. Allan deviation was used to characterize the long-term performance of the CO sensor, and a measurement precision of ∼3.4 ppbv was observed with an optimal integration time of ∼114 s. As a field measurement, a continuous monitoring on indoor CO concentration for a period of 24 h was conducted, which verified the reliable and robust operation of the developed sensor.

  15. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 Annual Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire ...

  16. Low correlation between household carbon monoxide and particulate matter concentrations from biomass-related pollution in three resource-poor settings

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, Elizabeth M.; Wills, Beatriz [Division of Pulmonary and Critical Care, School of Medicine, Johns Hopkins University, Baltimore (United States); Naithani, Neha [Division of Pulmonary and Critical Care, School of Medicine, Johns Hopkins University, Baltimore (United States); Nepal Nutrition Intervention Project Sarlahi, Kathmandu (Nepal); Gilman, Robert H. [Program in Global Disease Epidemiology and Control, Bloomberg School of Public Health, Johns Hopkins University, Baltimore (United States); Tielsch, James M. [Department of Global Health, School of Public Health and Health Services, George Washington University, Washington DC (United States); Chiang, Marilu [Biomedical Research Unit, A.B. PRISMA, Lima (Peru); Khatry, Subarna [Nepal Nutrition Intervention Project Sarlahi, Kathmandu (Nepal); Breysse, Patrick N. [Department of Environmental Health Sciences, Bloomberg School of Public Health, Johns Hopkins University, Baltimore (United States); Menya, Diana [School of Public Health, Moi University, Eldoret (Kenya); AMPATH (Academic Model Providing Access to Healthcare), Eldoret (Kenya); Apaka, Cosmas [AMPATH (Academic Model Providing Access to Healthcare), Eldoret (Kenya); Carter, E. Jane; Sherman, Charles B. [AMPATH (Academic Model Providing Access to Healthcare), Eldoret (Kenya); Division of Pulmonary Medicine, The Warren Alpert School of Medicine, Brown University, Providence (United States); Miranda, J. Jaime [CRONICAS Center of Excellence in Chronic Diseases, Universidad Peruana Cayetano Heredia, Lima (Peru); Checkley, William, E-mail: wcheckl1@jhmi.edu [Division of Pulmonary and Critical Care, School of Medicine, Johns Hopkins University, Baltimore (United States); Program in Global Disease Epidemiology and Control, Bloomberg School of Public Health, Johns Hopkins University, Baltimore (United States); CRONICAS Center of Excellence in Chronic Diseases, Universidad Peruana Cayetano Heredia, Lima (Peru)

    2015-10-15

    Household air pollution from the burning of biomass fuels is recognized as the third greatest contributor to the global burden of disease. Incomplete combustion of biomass fuels releases a complex mixture of carbon monoxide (CO), particulate matter (PM) and other toxins into the household environment. Some investigators have used indoor CO concentrations as a reliable surrogate of indoor PM concentrations; however, the assumption that indoor CO concentration is a reasonable proxy of indoor PM concentration has been a subject of controversy. We sought to describe the relationship between indoor PM{sub 2.5} and CO concentrations in 128 households across three resource-poor settings in Peru, Nepal, and Kenya. We simultaneously collected minute-to-minute PM{sub 2.5} and CO concentrations within a meter of the open-fire stove for approximately 24 h using the EasyLog-USB-CO data logger (Lascar Electronics, Erie, PA) and the personal DataRAM-1000AN (Thermo Fisher Scientific Inc., Waltham, MA), respectively. We also collected information regarding household construction characteristics, and cooking practices of the primary cook. Average 24 h indoor PM{sub 2.5} and CO concentrations ranged between 615 and 1440 μg/m{sup 3}, and between 9.1 and 35.1 ppm, respectively. Minute-to-minute indoor PM{sub 2.5} concentrations were in a safe range (<25 μg/m{sup 3}) between 17% and 65% of the time, and exceeded 1000 μg/m{sup 3} between 8% and 21% of the time, whereas indoor CO concentrations were in a safe range (<7 ppm) between 46% and 79% of the time and exceeded 50 ppm between 4%, and 20% of the time. Overall correlations between indoor PM{sub 2.5} and CO concentrations were low to moderate (Spearman ρ between 0.59 and 0.83). There was also poor agreement and evidence of proportional bias between observed indoor PM{sub 2.5} concentrations vs. those estimated based on indoor CO concentrations, with greater discordance at lower concentrations. Our analysis does not support the

  17. Low correlation between household carbon monoxide and particulate matter concentrations from biomass-related pollution in three resource-poor settings

    International Nuclear Information System (INIS)

    Klasen, Elizabeth M.; Wills, Beatriz; Naithani, Neha; Gilman, Robert H.; Tielsch, James M.; Chiang, Marilu; Khatry, Subarna; Breysse, Patrick N.; Menya, Diana; Apaka, Cosmas; Carter, E. Jane; Sherman, Charles B.; Miranda, J. Jaime; Checkley, William

    2015-01-01

    Household air pollution from the burning of biomass fuels is recognized as the third greatest contributor to the global burden of disease. Incomplete combustion of biomass fuels releases a complex mixture of carbon monoxide (CO), particulate matter (PM) and other toxins into the household environment. Some investigators have used indoor CO concentrations as a reliable surrogate of indoor PM concentrations; however, the assumption that indoor CO concentration is a reasonable proxy of indoor PM concentration has been a subject of controversy. We sought to describe the relationship between indoor PM 2.5 and CO concentrations in 128 households across three resource-poor settings in Peru, Nepal, and Kenya. We simultaneously collected minute-to-minute PM 2.5 and CO concentrations within a meter of the open-fire stove for approximately 24 h using the EasyLog-USB-CO data logger (Lascar Electronics, Erie, PA) and the personal DataRAM-1000AN (Thermo Fisher Scientific Inc., Waltham, MA), respectively. We also collected information regarding household construction characteristics, and cooking practices of the primary cook. Average 24 h indoor PM 2.5 and CO concentrations ranged between 615 and 1440 μg/m 3 , and between 9.1 and 35.1 ppm, respectively. Minute-to-minute indoor PM 2.5 concentrations were in a safe range (<25 μg/m 3 ) between 17% and 65% of the time, and exceeded 1000 μg/m 3 between 8% and 21% of the time, whereas indoor CO concentrations were in a safe range (<7 ppm) between 46% and 79% of the time and exceeded 50 ppm between 4%, and 20% of the time. Overall correlations between indoor PM 2.5 and CO concentrations were low to moderate (Spearman ρ between 0.59 and 0.83). There was also poor agreement and evidence of proportional bias between observed indoor PM 2.5 concentrations vs. those estimated based on indoor CO concentrations, with greater discordance at lower concentrations. Our analysis does not support the notion that indoor CO concentration is a

  18. Effect of vegetation in reducing carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, J C

    1977-01-01

    Carbon monoxide is a product of incomplete combustion. Because almost all of this gas is produced by motor vehicles, it is considered to have a line rather than a stationary point source. Greatest concentrations of this lethal gas correspond to periods of peak traffic volume and congestion; therefore, there are two daily periods of maxima and minima. Carbon monoxide cannot be detected by sight or smell. For this reason, this gas is especially deadly. During the summer of 1975, a study involving carbon monoxide concentrations at selected sites in Sendai was undertaken in conjunction with an ongoing investigation of urban pollution under the directorship of Professor Toshio Noh of Tohoku University. This study was made possible by a grant from the Japan Society for the Promotion of Science. 5 references, 5 figures, 1 table.

  19. Catalytic hydrogenation of carbon monoxide

    International Nuclear Information System (INIS)

    Wayland, B.B.

    1993-12-01

    Focus of this project is on developing new approaches for hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. The strategies to accomplish CO reduction are based on favorable thermodynamics manifested by rhodium macrocycles for producing a series of intermediates implicated in the catalytic hydrogenation of CO. Metalloformyl complexes from reactions of H 2 and CO, and CO reductive coupling to form metallo α-diketone species provide alternate routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics are promising candidates for future development

  20. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  1. New Class of Hybrid Materials for Detection, Capture, and "On-Demand" Release of Carbon Monoxide.

    Science.gov (United States)

    Pitto-Barry, Anaïs; Lupan, Alexandru; Ellingford, Christopher; Attia, Amr A A; Barry, Nicolas P E

    2018-04-25

    Carbon monoxide (CO) is both a substance hazardous to health and a side product of a number of industrial processes, such as methanol steam reforming and large-scale oxidation reactions. The separation of CO from nitrogen (N 2 ) in industrial processes is considered to be difficult because of the similarities of their electronic structures, sizes, and physicochemical properties (e.g., boiling points). Carbon monoxide is also a major poison in fuel cells because of its adsorption onto the active sites of the catalysts. It is therefore of the utmost economic importance to discover new materials that enable effective CO capture and release under mild conditions. However, methods to specifically absorb and easily release CO in the presence of contaminants, such as water, nitrogen, carbon dioxide, and oxygen, at ambient temperature are not available. Here, we report the simple and versatile fabrication of a new class of hybrid materials that allows capture and release of carbon monoxide under mild conditions. We found that carborane-containing metal complexes encapsulated in networks made of poly(dimethylsiloxane) react with CO, even when immersed in water, leading to dramatic color and infrared signature changes. Furthermore, we found that the CO can be easily released from the materials by simply dipping the networks into an organic solvent for less than 1 min, at ambient temperature and pressure, which not only offers a straightforward recycling method, but also a new method for the "on-demand" release of carbon monoxide. We illustrated the utilization of the on-demand release of CO from the networks by carrying out a carbonylation reaction on an electron-deficient metal complex that led to the formation of the CO-adduct, with concomitant recycling of the gel. We anticipate that our sponge-like materials and scalable methodology will open up new avenues for the storage, transport, and controlled release of CO, the silent killer and a major industrial poison.

  2. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  3. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ... 2011 Annual Estimates View All CO-Related Injury Statistics and Technical Reports Related Links Recalls Safety Education ...

  4. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... CONSUMER PRODUCT SAFETY COMMISSION Search CPSC Search Menu Home Recalls Recall List CPSC Recall API Recall Lawsuits ... and Bans Report an Unsafe Product Consumers Businesses Home Safety Education Safety Education Centers Carbon Monoxide Information ...

  5. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  6. The electric dipole moment of cobalt monoxide, CoO

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Xiujuan, E-mail: zhuangxj@hnu.edu.cn [College of Physics and Microelectronics Science, Key Laboratory for Micro-Nano Physics and Technology of Hunan Province, Hunan University, Changsha 410082 (China); Steimle, Timothy C. [Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287-1604 (United States)

    2014-03-28

    A number of low-rotational lines of the E{sup 4}Δ{sub 7/2} ← X{sup 4}Δ{sub 7/2} (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h{sub 7/2}, and the electron quadrupole parameter, eQq{sub 0}, for the E{sup 4}Δ{sub 7/2}(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ{sup -vector}{sub el}, for the X{sup 4}Δ{sub 7/2} (υ = 0) and E{sup 4}Δ{sub 7/2} (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F′ = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F′ = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  7. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Español The Invisible Killer Carbon monoxide, also known as CO, is called the "Invisible Killer" because it's ... used or incorrectly-vented fuel-burning appliances such as furnaces, stoves, water heaters and fireplaces. Watch This ...

  8. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Investigations Associated with Non-Fire Carbon Monoxide from Engine-Driven Generators and Other Engine-Driven Tools, 2004–2014 JANUARY 08, 2015 Non- ... outside of the Federal Government. CPSC does not control this external site or its privacy policy and ...

  9. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Sevinc, A.; Savli, H.; Atmaca, H. [Gaziantep University, Gaziantep (Turkey). School of Medicine

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  10. Polyketones as alternating copolymers of carbon monoxide

    International Nuclear Information System (INIS)

    Belov, Gennady P; Novikova, Elena V

    2004-01-01

    Characteristic features of the catalytic synthesis of alternating copolymers of carbon monoxide with various olefins, dienes, styrene and its derivatives are considered. The diversity of catalyst systems used for the copolymerisation of carbon monoxide is demonstrated and their influence on the structure and the molecular mass of the resulting copolymers is analysed. The data on the structure and physicochemical and mechanical properties of this new generation of functional copolymers are generalised and described systematically for the first time.

  11. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker...... after an acute exposure to carbon monoxide. This complication was diagnosed by pure-tone audiometry and confirmed by transient evoked otoacoustic emissions. Hearing loss has not improved after 3 months of followup....

  12. Adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Etherton, B.P.

    1980-01-01

    The adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts which were examined by a scanning transmission electron microscope (STEM). The metal particle size and number of particles per area of catalyst increased with increasing metal loading. The particles were approx. 10 A. in diameter, cubo-octahedral shaped, and approx. 80-90% disperse. The STEM electron beam caused negligible damage to the samples. Hydrogen adsorption measurements showed that the hydrogen-iridium atom ratio was 1.2:1-1.3:1 and increased with decreasing metal loading. Temperature-programed desorption showed four types of adsorbed hydrogen desorbing at -90/sup 0/C (I), 15/sup 0/C (IV), 115/sup 0/C (II), and 245/sup 0/C (III). Types II and IV desorb from single atom sites and Types I and III from multiple atom sites. Type I is in rapid equilibrium with the gas phase. All desorption processes appear to be first order. Carbon monoxide adsorbed nondissociatively at 25/sup 0/C with approx. 0.7:1 CO/Ir atom ratio. It adsorbed primarily in linear forms at low coverage, but a bridged form appeared at high coverage.

  13. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Science.gov (United States)

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  14. Carbon monoxide exposure in households in Ciudad Juárez, México.

    Science.gov (United States)

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  15. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  16. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Science.gov (United States)

    2010-07-01

    ... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration. Prior... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  17. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Directory of Open Access Journals (Sweden)

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  18. Occupational medicine effects of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, W.M. [South African Society of Occupational Medicine (South Africa)

    1998-10-01

    Carbon monoxide can affect the body if it is inhaled or if liquid carbon monoxide comes in contact with the eyes or skin. The effects of overexposure are discussed and a brief explanation of the toxicological effects of CO given. Methods of control of CO from common operations (exhaust fumes of internal combustion engines, the chemical industry and foundries, welding, mines or tunnels, fire damp explosions, industrial heating) are by local exhaust ventilation or use of a respiratory protective device. The South African hazardous chemical substance regulation NO. R. 1179 of 25 August 1995 stipulates maximum safe levels of CO concentration. 4 refs., 1 photo.

  19. Carbon monoxide poisoning from waterpipe smoking: a retrospective cohort study.

    Science.gov (United States)

    Eichhorn, Lars; Michaelis, Dirk; Kemmerer, Michael; Jüttner, Björn; Tetzlaff, Kay

    2018-04-01

    Waterpipe smoking may increasingly account for unintentional carbon monoxide poisoning, a serious health hazard with high morbidity and mortality. We aimed at identifying waterpipe smoking as a cause for carbon monoxide poisoning in a large critical care database of a specialty care referral center. This retrospective cohort study included patients with a history of exposure to waterpipe smoking and carbon monoxide blood gas levels >10% or presence of clinical symptoms compatible with CO poisoning admitted between January 2013 and December 2016. Patients' initial symptoms and carbon monoxide blood levels were retrieved from records and neurologic status was assessed before and after hyperbaric oxygen treatment. Sixty-one subjects with carbon monoxide poisoning were included [41 males, 20 females; mean age 23 (SD ± 6) years; range 13-45] with an initial mean carboxyhemoglobin of 26.93% (SD ± 9.72). Most common symptoms included syncope, dizziness, headache, and nausea; 75% had temporary syncope. Symptoms were not closely associated with blood COHb levels. CO poisoning after waterpipe smoking may present in young adults with a wide variability of symptoms from none to unconsciousness. Therefore diagnosis should be suspected even in the absence of symptoms.

  20. Method of removing nitrogen monoxide from a nitrogen monoxide-containing gas using a water-soluble iron ion-dithiocarbamate, xanthate or thioxanthate

    Science.gov (United States)

    Liu, D. Kwok-Keung; Chang, Shih-Ger

    1987-08-25

    The present invention relates to a method of removing of nitrogen monoxide from a nitrogen monoxide-containing gas which method comprises contacting a nitrogen oxide-containing gas with an aqueous solution of water soluble organic compound-iron ion chelate complex. The NO absorption efficiency of ferrous urea-dithiocarbamate and ferrous diethanolamine-xanthate as a function of time, oxygen content and solution ph is presented. 3 figs., 1 tab.

  1. Hydrothermal Synthesis of Pt-, Fe-, and Zn-doped SnO2 Nanospheres and Carbon Monoxide Sensing Properties

    Directory of Open Access Journals (Sweden)

    Weigen Chen

    2013-01-01

    Full Text Available Pure and M-doped (M = Pt, Fe, and Zn SnO2 nanospheres were successfully synthesized via a simple and facile hydrothermal method and characterized by X-ray powder diffraction, field-emission scanning electron microscopy, and energy dispersive spectroscopy. Chemical gas sensors were fabricated based on the as-synthesized nanostructures, and carbon monoxide sensing properties were systematically measured. Compared to pure, Fe-, and Zn-doped SnO2 nanospheres, the Pt-doped SnO2 nanospheres sensor exhibits higher sensitivity, lower operating temperature, more rapid response and recovery, better stability, and excellent selectivity. In addition, a theoretical study based on the first principles calculation was conducted. All results demonstrate the potential of Pt dopant for improving the gas sensing properties of SnO2-based sensors to carbon monoxide.

  2. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  3. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  4. Hydrogen bonding of formamide, urea, urea monoxide and their thio

    Indian Academy of Sciences (India)

    Ab initio and DFT methods have been employed to study the hydrogen bonding ability of formamide, urea, urea monoxide, thioformamide, thiourea and thiourea monoxide with one water molecule and the homodimers of the selected molecules. The stabilization energies associated with themonohydrated adducts and ...

  5. Carbon dioxide elimination and regeneration of resources in a microwave plasma torch

    International Nuclear Information System (INIS)

    Uhm, Han S.; Kwak, Hyoung S.; Hong, Yong C.

    2016-01-01

    Carbon dioxide gas as a working gas produces a stable plasma-torch by making use of 2.45 GHz microwaves. The temperature of the torch flame is measured by making use of optical spectroscopy and a thermocouple device. Two distinctive regions are exhibited, a bright, whitish region of a high-temperature zone and a bluish, dimmer region of a relatively low-temperature zone. The bright, whitish region is a typical torch based on plasma species where an analytical investigation indicates dissociation of a substantial fraction of carbon dioxide molecules, forming carbon monoxides and oxygen atoms. The emission profiles of the oxygen atoms and the carbon monoxide molecules confirm the theoretical predictions of carbon dioxide disintegration in the torch. Various hydrocarbon materials may be introduced into the carbon dioxide torch, regenerating new resources and reducing carbon dioxide concentration in the torch. As an example, coal powders in the carbon dioxide torch are converted into carbon monoxide according to the reaction of CO_2 + C → 2CO, reducing a substantial amount of carbon dioxide concentration in the torch. In this regards, the microwave plasma torch may be one of the best ways of converting the carbon dioxides into useful new materials. - Highlights: • Carbon dioxide gas produces a plasma-torch by making use of 2.45 GHz microwaves. • The temperature measurement of torch flame by optical spectroscopy. • Disintegration of carbon dioxide into carbon monoxide and oxygen atom. • Emission profiles of carbon monoxide confirm disintegration theory. • Conversion of carbon dioxide into carbon monoxide in the plasma torch. - This article presents carbon-dioxide plasma torch operated by microwaves and its applications to regeneration of new resources, eliminating carbon dioxide molecules.

  6. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  7. Carbon monoxide poisoning - Immediate diagnosis and treatment are crucial to avoid complications.

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, L.D. [Case Western Reserve University, Cleveland, OH (United States)

    2006-03-15

    Carbon monoxide is an odorless, colorless, tasteless gas produced by the incomplete combustion of carbon-containing fuels (oil, kerosene, coal, wood) or the inadequate ventilation of natural gas. When carbon monoxide is introduced into the bloodstream, it binds to hemoglobin, reducing the number of binding sites available for oxygen. Carbon monoxide also changes the structure of the hemoglobin molecule, which makes it even more difficult for oxygen that has attached to be released into tissues. The resulting tissue ischemia can lead to organ failure, permanent changes in cognition, or death. Carbon monoxide poisoning is the leading cause of death by poisoning in industrialized countries.

  8. A survey of the use of electronic scientific information resources among medical and dental students

    Directory of Open Access Journals (Sweden)

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  9. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  10. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  11. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  12. Pulmonary edema in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk

    1974-01-01

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis

  13. Pulmonary edema in acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis.

  14. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  15. Carbon monoxide and COHb concentration in blood in various circumstances

    Energy Technology Data Exchange (ETDEWEB)

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  16. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Science.gov (United States)

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  17. Carbon monoxide migratory insertion - A comparison of cationic and neutral palladium(II) complexes

    International Nuclear Information System (INIS)

    Frankcombe, K.; Cavell, K.J.; Yates, B.F.; Knott, R.B.

    1998-01-01

    With the use of ANSTO's resources and expertise and with support from AINSE, we have carried out extensive computer modelling on the mechanism of the palladium catalysed carbonylation reaction, a process which is used industrially in the conversion of carbon monoxide into biodegradable polymers. In this project, experimental and theoretical work has focussed on using Pd(II) complexes containing pyridine carboxylate ligands (NC 5 H 4 COO ) to explore the fundamental mechanistic steps. The results for subsequent steps in the catalytic cycle are presented and their implication for the design of more efficient catalysts are discussed

  18. CO2 Reduction Catalyzed by Nitrogenase: Pathways to Formate, Carbon Monoxide, and Methane

    OpenAIRE

    Khadka, Nimesh; Dean, Dennis R.; Smith, Dayle; Hoffman, Brian M.; Raugei, Simone; Seefeldt, Lance C.

    2016-01-01

    The reduction of N2 to NH3 by Mo-dependent nitrogenase at its active-site metal cluster FeMo-cofactor utilizes reductive elimination (re) of Fe-bound hydrides with obligatory loss of H2 to activate the enzyme for binding/reduction of N2. Earlier work showed that wild type nitrogenase and a nitrogenase having amino acid substitutions in the MoFe protein near FeMo-cofactor can catalytically reduce CO2 by 2 or 8 electrons/protons to carbon monoxide (CO) and methane (CH4) at low rates. Here, it i...

  19. Copolymerization of carbon monoxide and styrene catalyzed by resin-supported palladium polymer

    Directory of Open Access Journals (Sweden)

    2007-02-01

    Full Text Available Polyketone was prepared by the copolymerization of carbon monoxide (CO and styrene (ST catalyzed by o-phenylenediamine resin-supported palladium acetate. Effects of each catalytic system component such as 2,2’-bipyridine, 1,4-quinone and p-toluene-sulphonate on the copolymerization were investigated. The resin-supported catalyst and the copolymerization product were characterized by infrared spectroscopy (IR, differential scanning calorimetry (DSC, thermogravimetry (TG, X-ray photoelectron spectroscopy (XPS, Scanning Electron Microscopy (SEM. Results indicated that the resin-supported catalyst has excellent catalytic property. Furthermore, partial catalytic activity was maintained after the catalyst was used for five times.

  20. Poisoning by carbon monoxide in Morocco from 1991 to 2008.

    Science.gov (United States)

    Aghandous, Rachida; Chaoui, Hanane; Rhalem, Naima; Semllali, Ilham; Badri, Mohamed; Soulaymani, Abdelmajid; Ouammi, Lahcen; Soulaymani-Bencheikh, Rachida

    2012-04-01

    To describe the characteristics relating to the provenance of statements, patients and to evaluate the spatiotemporal evolution of carbon monoxide poisoning reported to Poison Control Center and Pharmacovigilance of Morocco (CAPM). This is a retrospective study over a period of 18 years from 1991 to 2008, for all cases of poisoning by carbon monoxide reported to CAPM. The epidemiological study focused on 12 976 cases of carbon monoxide poisoning reported to CAPM between 1991 and 2008. The average age of patients was 25.5 +/- 15.6 years, sex ratio was 0.5. The poisoning occurred by accident in 98.7% of cases, especially at home (96.7%) and in cold months. The urban population was the most affected (89.0%). The region of Meknes Tafilalt was the most concerned with 16.6% of cases. The symptomatology was characterized by the predominance of gastrointestinal tract diseases (37.1%). Deaths have reached a percentage of 0.9%. These qualitative and quantitative information is useful to highlight warnings and plan a strategy against carbon monoxide poisoning in Morocco.

  1. Carbon monoxide, smoking, and atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Astrup, P

    1973-10-01

    Studies on the effects of carbon monoxide and smoking on atherosclerosis are reviewed. Nonsmokers do not run the risk of getting significantly elevated carboxyhemoglobin levels from automobile exhaust in the streets, however, they do run the risk of getting elevated carboxyhemoglobin levels from exposure to CO in closed areas such as garages and tunnels. Carboxyhemoglobin levels up to 20 percent may also be found in smokers. The central nervous system seems to be influenced by carboxyhemoglobin concentrations up to 20 percent. The myocardium may also be affected. Experimental work with rabbits exposed to carbon monoxide and cholesterol is described which proved that CO has a damaging effect on arterial walls, leading to increased permeability for various plasma components, to the formation of subendothelial edema, and to increased atheromatosis. The results indicate that the much higher risk of smokers of developing arterial disease in comparison to nonsmokers is mainly due to the inhaled CO in the tobacco smoke and not to nicotine. (Air Pollut. Abstr.)

  2. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  3. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  4. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    African Journals Online (AJOL)

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  5. Protect Yourself from Carbon Monoxide Poisoning

    Centers for Disease Control (CDC) Podcasts

    2007-11-20

    Learn about carbon monoxide - a colorless, odorless gas - and how to protect yourself and your family.  Created: 11/20/2007 by CDC National Center for Environmental Health.   Date Released: 12/4/2007.

  6. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Science.gov (United States)

    2010-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  7. [Protective effects of endogenous carbon monoxide against myocardial ischemia-reperfusion injury in rats].

    Science.gov (United States)

    Zhou, Zhen; Ma, Shuang; Liu, Jie; Ji, Qiao-Rong; Cao, Cheng-Zhu; Li, Xiao-Na; Tang, Feng; Zhang, Wei

    2018-04-25

    The present study is aimed to explore the effects of endogenous carbon monoxide on the ischemia-reperfusion in rats. Wistar rats were intraperitoneally injected with protoporphyrin cobalt chloride (CoPP, an endogenous carbon monoxide agonist, 5 mg/kg), zinc protoporphyrin (ZnPP, an endogenous carbon monoxide inhibitor, 5 mg/kg) or saline. Twenty-four hours after injection, the myocardial ischemia-reperfusion model was made by Langendorff isolated cardiac perfusion system, and cardiac function parameters were collected. Myocardial cGMP content was measured by ELISA, and the endogenous carbon monoxide in plasma and myocardial enzymes in perfusate at 10 min after reperfusion were measured by colorimetry. The results showed that before ischemia the cardiac functions of CoPP, ZnPP and control groups were stable, and there were no significant differences. After reperfusion, cardiac functions had significant differences among the three groups (P endogenous carbon monoxide can maintain cardiac function, shorten the time of cardiac function recovery, and play a protective role in cardiac ischemia-reperfusion.

  8. Carbon monoxide and carbon dioxide interaction with tantalum

    International Nuclear Information System (INIS)

    Belov, V.D.; Ustinov, Yu.K.; Komar, A.P.

    1978-01-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (α and β' 1 ) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the β' 1 state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10 12 sec -1 , and γ = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively. (Auth.)

  9. Carbon monoxide and carbon dioxide interaction with tantalum

    Energy Technology Data Exchange (ETDEWEB)

    Belov, V D; USTINOV, YU K; KOMAR, A P [AN SSSR, LENINGRAD. FIZIKO-TEKHNICHESKIJ INST.

    1978-03-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (..cap alpha.. and ..beta..'/sub 1/) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the ..beta..'/sub 1/ state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10/sup 12/ sec/sup -1/, and ..gamma.. = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively.

  10. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  11. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  12. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    Science.gov (United States)

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  13. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Science.gov (United States)

    Wu, Martin; Ren, Qinghu; Durkin, A Scott; Daugherty, Sean C; Brinkac, Lauren M; Dodson, Robert J; Madupu, Ramana; Sullivan, Steven A; Kolonay, James F; Haft, Daniel H; Nelson, William C; Tallon, Luke J; Jones, Kristine M; Ulrich, Luke E; Gonzalez, Juan M; Zhulin, Igor B; Robb, Frank T; Eisen, Jonathan A

    2005-11-01

    We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO) as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  14. Life in Hot Carbon Monoxide: The Complete Genome Sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  15. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Directory of Open Access Journals (Sweden)

    Martin Wu

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  16. Four deaths due to carbon monoxide poisoning in car washes.

    Science.gov (United States)

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  17. CW-Laser-Induced Solid-State Reactions in Mixed Micron-Sized Particles of Silicon Monoxide and Titanium Monoxide: Nano-Structured Composite with Visible Light Absorption

    Czech Academy of Sciences Publication Activity Database

    Křenek, T.; Tesař, J.; Kupčík, Jaroslav; Netrvalová, M.; Pola, M.; Jandová, Věra; Pokorná, Dana; Cuřínová, Petra; Bezdička, Petr; Pola, Josef

    2017-01-01

    Roč. 27, č. 6 (2017), s. 1640-1648 ISSN 1574-1443 Institutional support: RVO:61388980 ; RVO:67985858 Keywords : Cw CO2 laser heating * IR laser imaging * Silicon monoxide * Solid state redox reactions * Ti/Si/O composite * Titanium monoxide Subject RIV: CA - Inorganic Chemistry; CI - Industrial Chemistry, Chemical Engineering (UCHP-M) OBOR OECD: Inorganic and nuclear chemistry; Chemical process engineering (UCHP-M) Impact factor: 1.577, year: 2016

  18. The Effect of Carbon Monoxide Poisoning on Platelet Volume in Children

    Directory of Open Access Journals (Sweden)

    Halise Akça

    2017-04-01

    Full Text Available Introduction: Carbon monoxide poisoning is one of the most important causes of morbidity and mortality. There is increasing evidence supporting the important role of mean platelet volume (MPV as a marker of hypoxia and inflammation. In this study, we aimed to determine changes in MPV values in pediatric patients with carbon monoxide poisoning. Methods: We retrospectively evaluated children who were diagnosed with carbon monoxide poisoning in our hospital between January 2005 and 2014. Results: We included 228 children with carbon monoxide poisoning (49% male in this retrospective, controlled study. The mean age of the patients was 88±56 months. Control group consisted of 200 age-matched healthy children. There was no statistically significant difference in MPV levels between the study and control groups (8.43±1.1 fL and 8.26±0.7 fL, respectively. No correlation of MPV and platelet count with carboxyhemoglobin (COHb was found. Conclusion: In our study, it was determined that MPV value was not a helpful parameter for predicting the diagnosis of acute carbon monoxide poisoning in childhood. The difference between the MPV values and the lack of significance and the absence of correlation between MPV value and COHb level led to the fact that MPV was not a guide indicating the clinical severity of the condition.

  19. New reduced variant in gadolinium and samarium monoxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Bist, B M.S.; Kumar, J; Srivastava, O N [Banaras Hindu Univ. (India). Dept. of Physics

    1977-01-01

    A new reduced phase has been observed in the thin films of gadolinium and samarium monoxides. This phase results on imparting an annealing treatment to the monoxides and is formed as a result of the creation and ordering of vacancies in the oxygen sublattice. The new phase has been analysed to possess a rhombohedral unit cell with lattice parameters a/sub R/ = a/sub 0/ square root of (3/2) and c/sub R/ = a/sub 0/ square root of 3 (based on hexagonal axes, a/sub 0/ being the lattice parameter of the fundamental zinc blende type unit cell of the monoxide). Based on the proposed structure, the new phase can be assigned the solid state chemical formula RO/sub x/ where R = Gd, Sm and x = 0.66.

  20. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  1. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  2. Carbon monoxide may be an important molecule in migraine and other headaches

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Schytz, Henrik W; Hauge, Mette K

    2014-01-01

    INTRODUCTION: Carbon monoxide was previously considered to just be a toxic gas. A wealth of recent information has, however, shown that it is also an important endogenously produced signalling molecule involved in multiple biological processes. Endogenously produced carbon monoxide may thus play...

  3. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  4. CARBON MONOXIDE AND THE NERVOUS SYSTEM

    Science.gov (United States)

    Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and there...

  5. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Science.gov (United States)

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  6. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  7. Electron Stimulated Molecular Desorption of a NEG St 707 at Room Temperature

    CERN Document Server

    Le Pimpec, F; Laurent, Jean Michel

    2001-01-01

    Electron stimulated molecular desorption (ESD) from a NEG St 707 (SAES GettersTM) sample after conditioning and after saturation with isotopic carbon monoxide2,13C18O, has been studied on a laboratory setup. Measurements were performed using an electron beam of 300 eV kinetic energy, with an average electron intensity of 1.6 1015 electrons s-1. The electrons were impinging on the 15 cm2 target surface at perpendicular incidence. It is found that the desorption yields h (molecules/electron) of the characteristic gases in an UHV system (hydrogen, methane, water, carbon monoxide, carbon dioxide) for a fully activated NEG as well as for a NEG fully saturated with 13C18O are lower than for OFHC copper baked at 120oC. A small fraction only of the gas which is required to saturate the getter surface can be re-desorbed and thus appears to be accessible to ESD.

  8. Optimization of Treatment Policy for Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    R. N. Akalayev

    2012-01-01

    Full Text Available Objective: to evaluate the efficiency of combination use of hyperbaric oxygenation, succinate-containing solutions, and anti-edematous agents in patients with acute carbon monoxide poisoning. Subjects and methods. The results of treatment were analyzed in 32 patients admitted in 2009—2011 for severe acute carbon monoxide poisoning and a Glasgow coma score of 6—8. The patients were divided into 2 groups: 1 patients whose combination therapy involved hyperbaric oxygenation, Succinasol infusions, and L-lysine-aescinate injections; 2 those who received traditional therapy. All the patients underwent complex clinical, laboratory, and neurophysiologic examinations. Results. Just 24 hours after the combination use of Succinasol and L-lysine-aescinate, Group I patients were observed to have substantially reduced lactate, the content of the latter approached the normal value following 48 hours, which was much below the values in the control group. The similar pattern was observed when endogenous intoxication parameters were examined. During the performed therapy, the level of consciousness and that of intellect according to the MMSE and FAB scales were restored more rapidly in the study group patients than in Group 2. Conclusion. The combination use of hyperbaric oxygenation, the succinate-containing solution Succinasol, and the anti-edematous agent L-lysine-aescinate considerably enhances the efficiency of intensive therapy for acute carbon monoxide poisoning. Key words: carbon monoxide, toxic hypoxic encephalopathy, combination therapy, hyperbaric oxygenation, succinic acid, L-lysine-aescinate.

  9. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  10. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  11. Carbon Monoxide Exposure in Youth Ice Hockey.

    Science.gov (United States)

    Macnow, Theodore; Mannix, Rebekah; Meehan, William P

    2017-11-01

    To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.

  12. Catalytic Copolymerization of Ethene and Carbon Monoxide on Nickel Complexes.

    Science.gov (United States)

    Domhöver, Bernd; Kläui, Wolfgang; Kremer-Aach, Andreas; Bell, Ralf; Mootz, Dietrich

    1998-11-16

    Can palladium be replaced by nickel? For the industrial copolymerization of carbon monoxide and ethene a palladium catalyst is used which cannot be recovered-a cheaper procedure would be desirable. The presented complex 1 is the first structurally characterized nickel compound which does not polymerize ethene but a mixture from carbon monoxide and ethene unter mild conditions to give a perfectly alternating polyketone. © 1998 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  13. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Science.gov (United States)

    2010-07-01

    ....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Oxides of nitrogen, carbon monoxide...

  14. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Science.gov (United States)

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  15. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  16. Mechanism of obtaining carbon monoxide and hydrogen during brown coal radiolysis. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rustamov, V R; Kurbanov, M A; Dzantiev, B T; Kerimov, V K; Musaeva, P F

    1982-05-01

    This article analyzes effects of gamma radiation on the yield of products of coal gasification: hydrogen and carbon monoxide. Samples of brown coal from the Kansk-Achins basin were treated by gamma radiation with cobalt 60 radiation source. Analyses show that accumulation of hydrogen and carbon monoxide in brown coal under influence of gamma radiation is characterized by a constant rate. Yields of carbon monoxide and hydrogen amount to 0.16 molecule/100 electro volt and 0.21 molecule/electro volt respectively. Reducing radiation dose from 2.5 to 0.7 millirad/h reduces yields of hydrogen and carbon monoxide. Increasing temperature of vacuum brown coal pyrolysis from 200 to 600 C causes decrease of hydrogen yield. Hydrogen yield decrease during temperature increase is caused by a high content of aromatic nuclei in the samples used in the radiolysis. (5 refs.)

  17. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  18. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    Science.gov (United States)

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  19. Study on the surface oxidation resistance of uranium metal in the atmosphere of carbon monoxide

    International Nuclear Information System (INIS)

    Wang Xiaolin; Fu Yibei; Xie Renshou

    1999-01-01

    The surface reactions of different layers on uranium metal with carbon monoxide at 25, 80 and 200 degree C are studied by X-ray photoelectron spectroscopy (XPS). The experimental results show that the carbon monoxide is adsorbed on the surface oxide layer of uranium and interacted each other. The content of oxygen in the surface oxide and O/U ratio are decreased with increasing the exposure of carbon monoxide to the surface layer. The effect of reduction on the metal surface is more obviously with a higher temperature and increasing of layer thickness. The investigation indicates the uranium metal has resistance to further oxidation in the atmosphere of carbon monoxide

  20. XPS study on the surface reaction of uranium metal with carbon monoxide at 200 degree C

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-12-01

    The surface reaction of uranium metal with carbon monoxide at 200 degree C has been studied by X-ray photoelectron spectroscopy (XPS). The carbon monoxide adsorption on the surface oxide layer resulted in U4f peak shifting to the lower binding energy and the content of oxygen in the oxide is decreased. O/U radio decreases with increasing the exposure of carbon monoxide to the surface layer. The investigation indicated the surface layer of uranium metal was further reduced in the atmosphere of carbon monoxide at high temperature. (3 refs., 5 figs.)

  1. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    Energy Technology Data Exchange (ETDEWEB)

    Inui, Y. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)]. E-mail: inui@eee.tut.ac.jp; Urata, A. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Ito, N. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Nakajima, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Tanaka, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)

    2006-08-15

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide.

  2. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    International Nuclear Information System (INIS)

    Inui, Y.; Urata, A.; Ito, N.; Nakajima, T.; Tanaka, T.

    2006-01-01

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide

  3. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    Science.gov (United States)

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  4. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  5. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Science.gov (United States)

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  6. Chemical production from waste carbon monoxide: its potential for energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Rohrmann, C.A.; Schiefelbein, G.F.; Molton, P.M.; Li, C.T.; Elliott, D.C.; Baker, E.G.

    1977-11-01

    Results of a study of the potential for energy conservation by producing chemicals from by-product or waste carbon monoxide (CO) from industrial sources are summarized. Extensive compilations of both industrial sources and uses for carbon monoxide were developed and included. Reviews of carbon monoxide purification and concentration technology and preliminary economic evaluations of carbon monoxide concentration, pipeline transportation and utilization of CO in the synthesis of ammonia and methanol are included. Preliminary technical and economic feasibility studies were made of producing ammonia and methanol from the by-product CO produced by a typical elemental phosphorus plant. Methanol synthesis appears to be more attractive than ammonia synthesis when using CO feedstock because of reduced water gas shift and carbon dioxide removal requirements. The economic studies indicate that methanol synthesis from CO appears to be competitive with conventional technology when the price of natural gas exceeds $0.82/million Btu, while ammonia synthesis from CO is probably not competitive until the price of natural gas exceeds $1.90/million Btu. It is concluded that there appears to be considerable potential for energy conservation in the chemical industry, by collecting CO rather than flaring it, and using it to make major chemicals such as ammonia and methanol.

  7. Gas-Phase Energetics of Actinide Oxides: An Assessment of Neutral and Cationic Monoxides and Dioxides from Thorium to Curium

    Science.gov (United States)

    Marçalo, Joaquim; Gibson, John K.

    2009-09-01

    An assessment of the gas-phase energetics of neutral and singly and doubly charged cationic actinide monoxides and dioxides of thorium, protactinium, uranium, neptunium, plutonium, americium, and curium is presented. A consistent set of metal-oxygen bond dissociation enthalpies, ionization energies, and enthalpies of formation, including new or revised values, is proposed, mainly based on recent experimental data and on correlations with the electronic energetics of the atoms or cations and with condensed-phase thermochemistry.

  8. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    OpenAIRE

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been o...

  9. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    Science.gov (United States)

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  10. Modeling chemisorption kinetics of carbon monoxide on polycrystalline platinum

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, R.G.; Modell, M.; Baddour, R.F.

    1978-04-01

    Seven distinct desorption surface states of carbon monoxide on polycrystalline platinum were detected by deconvoluting temperature-programed desorption spectra of 4-100% carbon monoxide monolayer coverage. The adstates had fixed activation energies of desorption (22.5-32.6 kcal/mole) over the entire coverage range. Rates of formation and populations were derived. The chemisorption was modeled by a Hinshelwood-type expression which allowed for site creation and suggested that adsorbed molecules are sufficiently mobile during desorption heating to fill ordered states of minimum energy and that chemisorption into these states is noncompetitive and determined by the surface. Spectra, diagrams, graphs, tables, and 49 references.

  11. Enhancement of p-type mobility in tin monoxide by native defects

    KAUST Repository

    Granato, D. B.

    2013-05-31

    Transparent p-type materials with good mobility are needed to build completely transparent p-n junctions. Tin monoxide (SnO) is a promising candidate. A recent study indicates great enhancement of the hole mobility of SnO grown in Sn-rich environment [E. Fortunato et al., Appl. Phys. Lett. 97, 052105 (2010)]. Because such an environment makes the formation of defects very likely, we study defect effects on the electronic structure to explain the increased mobility. We find that Sn interstitials and O vacancies modify the valence band, inducing higher contributions of the delocalized Sn 5p orbitals as compared to the localized O 2p orbitals, thus increasing the mobility. This mechanism of valence band modification paves the way to a systematic improvement of transparent p-type semiconductors.

  12. Influence of carbon monoxide to the surface layer of uranium metal and its oxides

    International Nuclear Information System (INIS)

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-09-01

    The surface structures of uranium metal and triuranium octaoxide (U 3 O 8 ) and the influence of carbon monoxide to the surface layers have been studied by X-ray photoelectron spectroscopy (XPS). After exposure to carbon monoxide, contents of oxygen in the surface oxides of uranium metal and U 3 O 8 are decreased and O/U ratios decrease 7.2%, 8.0% respectively. The investigation indicated the surface layers of uranium metal and its oxides were forbidden to further oxidation in the atmosphere of carbon monoxide. (11 refs., 9 figs., 2 tabs.)

  13. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  14. Carbon Monoxide Hazards from Small Gasoline Powered Engines

    Science.gov (United States)

    ... DHHS (NIOSH) Publication No. 96-118 (1996) Describes health effects and current standards and guidelines relating to carbon monoxide, as well as recommendations for workers, employers, and manufacturers regarding small gasoline powered engine ...

  15. Extending the range of low energy electron diffraction (LEED) surface structure determination: Co-adsorbed molecules, incommensurate overlayers and alloy surface order studied by new video and electron counting LEED techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ogletree, D.F.

    1986-11-01

    LEED multiple scattering theory is briefly summarized, and aspects of electron scattering with particular significance to experimental measurements such as electron beam coherence, instrument response and phonon scattering are analyzed. Diffuse LEED experiments are discussed. New techniques that enhance the power of LEED are described, including a real-time video image digitizer applied to LEED intensity measurements, along with computer programs to generate I-V curves. The first electron counting LEED detector using a ''wedge and strip'' position sensitive anode and digital electronics is described. This instrument uses picoampere incident beam currents, and its sensitivity is limited only by statistics and counting times. Structural results on new classes of surface systems are presented. The structure of the c(4 x 2) phase of carbon monoxide adsorbed on Pt(111) has been determined, showing that carbon monoxide molecules adsorb in both top and bridge sites, 1.85 +- 0.10 A and 1.55 +- 0.10 A above the metal surface, respectively. The structure of an incommensurate graphite overlayer on Pt(111) is analyzed. The graphite layer is 3.70 +- 0.05 A above the metal surface, with intercalated carbon atoms located 1.25 +- 0.10 A above hollow sites supporting it. The (2..sqrt..3 x 4)-rectangular phase of benzene and carbon monoxide coadsorbed on Pt(111) is analyzed. Benzene molecules adsorb in bridge sites parallel to and 2.10 +- 0.10 A above the surface. The carbon ring is expanded, with an average C-C bond length of 1.72 +- 0.15 A. The carbon monoxide molecules also adsorb in bridge sites. The structure of the (..sqrt..3 x ..sqrt..3) reconstruction on the (111) face of the ..cap alpha..-CuAl alloy has been determined.

  16. Extending the range of low energy electron diffraction (LEED) surface structure determination: Co-adsorbed molecules, incommensurate overlayers and alloy surface order studied by new video and electron counting LEED techniques

    International Nuclear Information System (INIS)

    Ogletree, D.F.

    1986-11-01

    LEED multiple scattering theory is briefly summarized, and aspects of electron scattering with particular significance to experimental measurements such as electron beam coherence, instrument response and phonon scattering are analyzed. Diffuse LEED experiments are discussed. New techniques that enhance the power of LEED are described, including a real-time video image digitizer applied to LEED intensity measurements, along with computer programs to generate I-V curves. The first electron counting LEED detector using a ''wedge and strip'' position sensitive anode and digital electronics is described. This instrument uses picoampere incident beam currents, and its sensitivity is limited only by statistics and counting times. Structural results on new classes of surface systems are presented. The structure of the c(4 x 2) phase of carbon monoxide adsorbed on Pt(111) has been determined, showing that carbon monoxide molecules adsorb in both top and bridge sites, 1.85 +- 0.10 A and 1.55 +- 0.10 A above the metal surface, respectively. The structure of an incommensurate graphite overlayer on Pt(111) is analyzed. The graphite layer is 3.70 +- 0.05 A above the metal surface, with intercalated carbon atoms located 1.25 +- 0.10 A above hollow sites supporting it. The (2√3 x 4)-rectangular phase of benzene and carbon monoxide coadsorbed on Pt(111) is analyzed. Benzene molecules adsorb in bridge sites parallel to and 2.10 +- 0.10 A above the surface. The carbon ring is expanded, with an average C-C bond length of 1.72 +- 0.15 A. The carbon monoxide molecules also adsorb in bridge sites. The structure of the (√3 x √3) reconstruction on the (111) face of the α-CuAl alloy has been determined

  17. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  18. Transparent Oxide Semiconductors for Emerging Electronics

    KAUST Repository

    Caraveo-Frescas, Jesus Alfonso

    2013-11-01

    Transparent oxide electronics have emerged as promising materials to shape the future of electronics. While several n-type oxides have been already studied and demonstrated feasibility to be used as active materials in thin film transistors, high performance p-type oxides have remained elusive. This dissertation is devoted to the study of transparent p-type oxide semiconductor tin monoxide and its use in the fabrication of field effect devices. A complete study on the deposition of tin monoxide thin films by direct current reactive magnetron sputtering is performed. Carrier density, carrier mobility and conductivity are studied over a set of deposition conditions where p-type conduction is observed. Density functional theory simulations are performed in order to elucidate the effect of native defects on carrier mobility. The findings on the electrical properties of SnO thin films are then translated to the fabrication of thin films transistors. The low processing temperature of tin monoxide thin films below 200 oC is shown advantageous for the fabrication of fully transparent and flexible thin film transistors. After careful device engineering, including post deposition annealing temperature, gate dielectric material, semiconductor thickness and source and drain electrodes material, thin film transistors with record device performance are demonstrated, achieving a field effect mobility >6.7 cm2V-1s-1. Device performance is further improved to reach a field effect mobility of 10.8 cm2V-1s-1 in SnO nanowire field effect transistors fabricated from the sputtered SnO thin films and patterned by electron beam lithography. Downscaling device dimension to nano scale is shown beneficial for SnO field effect devices not only by achieving a higher hole mobility but enhancing the overall device performance including better threshold voltage, subthreshold swing and lower number of interfacial defects. Use of p-type semiconductors in nonvolatile memory applications is then

  19. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    Science.gov (United States)

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-11-01

    Small-size (carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction.

  20. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  1. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker a...

  2. The electronic structure of VO in its ground and electronically excited states: A combined matrix isolation and quantum chemical (MRCI) study

    International Nuclear Information System (INIS)

    Hübner, Olaf; Hornung, Julius; Himmel, Hans-Jörg

    2015-01-01

    The electronic ground and excited states of the vanadium monoxide (VO) molecule were studied in detail. Electronic absorption spectra for the molecule isolated in Ne matrices complement the previous gas-phase spectra. A thorough quantum chemical (multi-reference configuration interaction) study essentially confirms the assignment and characterization of the electronic excitations observed for VO in the gas-phase and in Ne matrices and allows the clarification of open issues. It provides a complete overview over the electronically excited states up to about 3 eV of this archetypical compound

  3. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    OpenAIRE

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  4. CT and clinical patterns in suicidal carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-12-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications.

  5. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Science.gov (United States)

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  6. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Science.gov (United States)

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  7. Kinetics of heterogeneous catalysis oxidation of carbon monoxide

    International Nuclear Information System (INIS)

    Khawaja, Y.; Sadiq, A.

    1987-10-01

    An irreversible kinetic surface-reaction model, based upon the reaction of carbon monoxide nd oxygen on a catalyst surface is investigated by means of Monte Carlo simulation. The adsorbed molecules/atoms on the surface undergo both first and second order kinetic phase transitions. The first order transition is found to occur at x/sub/co=x/sub/2=0.5255 with an error bar of 0.0003, where x/sub/co is the concentration of carbon monoxide in the gas phase. The time evolution of this catalytic reaction is studied both analytically and by computer simulation. Slightly above x/sub/2, the oxygen coverage relaxation time for the oxygen is found to diverage as the inverse of 3.54 times the absolute of the difference of x/sub/2 and x/sub/co. (orig./A.B.)

  8. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Science.gov (United States)

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  9. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Science.gov (United States)

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  10. Vaporization study on vanadium monoxide and two-phase mixture of vanadium and vanadium monoxide by mass-spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over single phase vanadium monoxide VO 1.022 (s) and the two-phase mixture of vanadium metal (β phase) and vanadium monoxide were measured by mass-spectrometric method in the temperature range of 1,803 ∼ 1,990 and 1,703 ∼ 1,884 K, respectively. The main gas species over both systems were found to be VO(g) and V(g). The vapor pressure of VO(g) over the two-phase mixture of V(s) and VO(s) was a little lower than that over single phase VO(s). The vapor pressure of V(g) over the two-phase mixture was nearly equal to that over single phase. From the vapor pressure data, the enthalpies of vaporization, the enthalpies of formation for VO(g) and V(g) and the dissociation energy of VO(g) were determined. The oxygen partial pressure was calculated as a function of temperature from the vapor pressures of VO(g) and V(g), from which the partial molar enthalpies and entropies of oxygen in both systems were obtained. (author)

  11. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    Science.gov (United States)

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  12. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  13. CT and clinical patterns in suicidal carbon monoxide

    International Nuclear Information System (INIS)

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-01-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications. (orig.) [de

  14. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Science.gov (United States)

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  15. Density function theory study of the adsorption and dissociation of carbon monoxide on tungsten nanoparticles.

    Science.gov (United States)

    Weng, Meng-Hsiung; Ju, Shin-Pon; Chen, Hsin-Tsung; Chen, Hui-Lung; Lu, Jian-Ming; Lin, Ken-Huang; Lin, Jenn-Sen; Hsieh, Jin-Yuan; Yang, Hsi-Wen

    2013-02-01

    The adsorption and dissociation properties of carbon monoxide (CO) molecule on tungsten W(n) (n = 10-15) nanoparticles have been investigated by density-functional theory (DFT) calculations. The lowest-energy structures for W(n) (n = 10-15) nanoparticles are found by the basin-hopping method and big-bang method with the modified tight-binding many-body potential. We calculated the corresponding adsorption energies, C-O bond lengths and dissociation barriers for adsorption of CO on nanoparticles. The electronic properties of CO on nanoparticles are studied by the analysis of density of state and charge density. The characteristic of CO on W(n) nanoparticles are also compared with that of W bulk.

  16. Environmental tobacco smoke exposure among non-smoking waiters: measurement of expired carbon monoxide levels

    Directory of Open Access Journals (Sweden)

    Ronaldo Laranjeira

    2000-07-01

    Full Text Available CONTEXT: Exposure to environmental tobacco smoke is a health risk that is of concern to patrons and of particular concern to employees of restaurants and bars. OBJECTIVE: To assess environmental tobacco smoke exposure (using expired carbon monoxide levels in non-smoking waiters before and after a normal day's shift and to compare pre-exposure levels with non-smoking medical students. DESIGN: An observational study. SETTING: Restaurants with more than 50 tables or 100 places in São Paulo. SUBJECTS: 100 non-smoking restaurant waiters and 100 non-smoking medical students in São Paulo, Brazil. MAIN MEASUREMENTS: Levels of expired carbon monoxide, measured with a Smokerlyser (Bedfont EC 50 Scientific, before and after a normal day's work. RESULTS: Waiters' pre-exposure expired carbon monoxide levels were similar to those of medical students, but after a mean of 9 hours exposure in the workplace, median levels more than doubled (2.0 ppm vs. 5.0 ppm, P <0.001. Post-exposure carbon monoxide levels were correlated with the number of tables available for smokers (Kendall's tau = 0.2, P <0.0001. CONCLUSIONS: Exposure to environmental tobacco smoke is the most likely explanation for the increase in carbon monoxide levels among these non-smoking waiters. These findings can be used to inform the ongoing public health debate on passive smoking.

  17. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Science.gov (United States)

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  18. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  19. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    OpenAIRE

    Metin Uysalol; Ezgi Paslı Uysalol; Gamze Varol Saraçoğlu; Semra Kayaoğlu

    2011-01-01

    Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female) who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide into...

  20. Assessment of exposure to carbon monoxide group of firefighters from fire fighting and rescue units

    Directory of Open Access Journals (Sweden)

    Jadwiga Lembas-Bogaczyk

    2011-03-01

    Full Text Available Firemen threat during fire burning of chemical substances indicated presence of carbon monoxide (CO in all cases. Carbon monoxide causes death of fire. Inhaled through respiratory system, links with hemoglobin, thus blocking transport and distribution of oxygen in the body. This leads to tissue anoxia, which is a direct threat to firefighters’ life. The purpose of this study was to assess the exposure to carbon monoxide of participating firefighters extinguishing fire. Estimation of carbon monoxide quantity absorbed by firefighters was isolated in a group of 40 firefighters from Fire Extinguishing and Rescue Unit of State Fire in Nysa. The study was conducted by measuring carbon monoxide in exhaled air. For measurement of carbon monoxide concentration in exhaled air Micro CO meter was used. Results were demonstrated separately for nonsmokers (n425 and smokers (n415. Mean COHb[%] levels in nonsmokers, measured prior the rescue action was 0,3950,3% and increased statistically significant after the action to 0,6150,34%, while in the group smokers, this level was 2,1750,64% before the action and increased insignificantly after the action to 2,3350,63%. The average COHb level in the same groups before and after exercise, was respectively: for nonsmokers prior to exercise was 0,4850,28% and after exercise decreased statistically significant to 0,3050,27%. In the group of smokers before exercise was 2,2350,61% and decreased statistically significant up to 1,5450,71%. It was no difference between the group of age and time of employment.

  1. Study on the influence of carbon monoxide to the surface oxide layer of uranium metal

    International Nuclear Information System (INIS)

    Wang Xiaolin; Duan Rongliang; Fu Yibei; Xie Renshou; Zuo Changming; Zhao Chunpei; Chen Hong

    1997-01-01

    The influence of carbon monoxide to the surface oxide layer of uranium metal has been studied by X-ray photoelectron spectroscopy (XPS) and gas chromatography (GC). Carbon monoxide adsorption on the oxide layer resulted in U4f peak shifting to the lower binding energy. The content of oxygen in the oxide is decreased and the atomic ratio (O/U) is decreased by 7.2%. The amount of carbon dioxide in the atmosphere after the surface reaction is increased by 11.0%. The investigation indicates that the surface layer can prevent the further oxidation uranium metal in the atmosphere of carbon monoxide

  2. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  3. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  4. Cell for studying electron-adsorbed gas interactions; Cellule d'etudes des interactions electron-gaz adsorbe

    Energy Technology Data Exchange (ETDEWEB)

    Golowacz, H; Degras, D A [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires, Deptartement de Physique des Plasmas et de la Fusion Controlee, Service de Physique Appliquee, Service de Physique des Interractions Electroniques, Section d' Etude des Interactions Gaz-Solides

    1967-07-01

    The geometry and the technology of a cell used for investigations on electron-adsorbed gas interactions are described. The resonance frequencies of the surface ions which are created by the electron impact on the adsorbed gas are predicted by simplified calculations. The experimental data relative to carbon monoxide and neon are in good agreement with these predictions. (authors) [French] Les caracteristiques geometriques et technologiques generales d'une cellule d'etude des interactions entre un faisceau d'electrons et un gaz adsorbe sont donnees. Un calcul simplifie permet de prevoir les frequences de resonance des ions de surface crees par l'impact des electrons sur le gaz adsorbe. Les donnees experimentales sur l'oxyde de carbone et le neon confirment les previsions du calcul. (auteurs)

  5. Production of Ethylene and Carbon Monoxide by Microorganisms

    Science.gov (United States)

    T. H. Filer; L. R. Brown; S. Brown-Sarobot; S. Martin

    1984-01-01

    Various quantities of ethylene and carbon monoxide were produced on PDA by Fusicladium effusum, Pestilotia nucicola, Alternaria tenuis, and Fusarium oxysporum subcultured from diseased pecan shucks. Repeated subculturing of these fungi on potato dextrose broth supplemented with iron powder produced ethylene. The production of...

  6. Ambient carbon monoxide and cardiovascular mortality: a nationwide time-series analysis in 272 cities in China.

    Science.gov (United States)

    Liu, Cong; Yin, Peng; Chen, Renjie; Meng, Xia; Wang, Lijun; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Kan, Haidong; Zhou, Maigeng

    2018-01-01

    Evidence of the acute health effects of ambient carbon monoxide air pollution in developing countries is scarce and mixed. We aimed to evaluate short-term associations between carbon monoxide and daily cardiovascular disease mortality in China. We did a nationwide time-series analysis in 272 major cities in China from January, 2013, to December, 2015. We extracted daily cardiovascular disease mortality data from China's Disease Surveillance Points system. Data on daily carbon monoxide concentrations for each city were obtained from the National Urban Air Quality Real-time Publishing Platform. City-specific associations between carbon monoxide concentrations and daily mortality from cardiovascular disease, coronary heart disease, and stroke were estimated with over-dispersed generalised linear models. Bayesian hierarchical models were used to obtain national and regional average associations. Exposure-response association curves and potential effect modifiers were evaluated. Two-pollutant models were fit to evaluate the robustness of the effects of carbon monoxide on cardiovascular mortality. The average annual mean carbon monoxide concentration in these cities from 2013 to 2015 was 1·20 mg/m 3 , ranging from 0·43 mg/m 3 to 2·45 mg/m 3 . For a 1 mg/m 3 increase in average carbon monoxide concentrations on the present day and previous day (lag 0-1), we observed significant increments in mortality of 1·12% (95% posterior interval [PI] 0·42-1·83) from cardiovascular disease, 1·75% (0·85-2·66) from coronary heart disease, and 0·88% (0·07-1·69) from stroke. These associations did not vary substantially by city, region, and demographic characteristics (age, sex, and level of education), and the associations for cardiovascular disease and coronary heart disease were robust to the adjustment of criteria co-pollutants. We did not find a threshold below which carbon monoxide exposure had no effect on cardiovascular disease mortality. This analysis is, to our

  7. Optimization of mass flow rate in RGTT200K coolant purification for Carbon Monoxide conversion process

    International Nuclear Information System (INIS)

    Sumijanto; Sriyono

    2016-01-01

    Carbon monoxide is a species that is difficult to be separated from the reactor coolant helium because it has a relatively small molecular size. So it needs a process of conversion from carbon monoxide to carbondioxide. The rate of conversion of carbon monoxide in the purification system is influenced by several parameters including concentration, temperature and mass flow rate. In this research, optimization of the mass flow rate in coolant purification of RGTT200K for carbon monoxide conversion process was done. Optimization is carried out by using software Super Pro Designer. The rate of reduction of reactant species, the growth rate between the species and the species products in the conversion reactions equilibrium were analyzed to derive the mass flow rate optimization of purification for carbon monoxide conversion process. The purpose of this study is to find the mass flow rate of purification for the preparation of the basic design of the RGTT200K coolant helium purification system. The analysis showed that the helium mass flow rate of 0.6 kg/second resulted in an un optimal conversion process. The optimal conversion process was reached at a mass flow rate of 1.2 kg/second. A flow rate of 3.6 kg/second – 12 kg/second resulted in an ineffective process. For supporting the basic design of the RGTT200K helium purification system, the mass flow rate for carbon monoxide conversion process is suggested to be 1.2 kg/second. (author)

  8. Cardiological aspects of carbon monoxide poisoning.

    Science.gov (United States)

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  9. Effect of N-Acetylcysteine in Protecting from Simultaneous Noise and Carbon Monoxide Induced Hair Cell Loss

    Directory of Open Access Journals (Sweden)

    Akram Pourbakht

    2011-06-01

    Full Text Available Background and Aim: N-acetylcysteine, a glutathione precursor and reactive oxygen species scavenger, is reported to be effective in reducing noise-induced hearing loss. Many workers in industry are exposed simultaneously to noise and chemical pollutants such as carbon monoxide. We investigated effectiveness of N-acetylcysteine in protecting the cochlea from simultaneous noise and carbon monoxide damages.Methods: Twelve rabbits were exposed simeltaneously to 100 dB sound pressure level of broad band noise and carbon monoxide 8 hours a day for 5 days. One hour before exposure, experimental group received 325 mg/kg of N-acetylcysteine while normal saline was administered for the control group. The protective effect of N-acetylcysteine was evaluated 3 weeks after exposure by histological assessment of the hair cells.Results: Simultaneous exposure to noise and carbon monoxide resulted in a considerable damage to the outer hair cells; however, the inner hair cells and the pillar cells remained intact. Use of N-acetylcysteine in the experimental group significantly reduced the extent of outer hair cell loss.Conclusion: N-acetylcysteine attenuates simultaneous noise and carbon monoxide induced hair cell damage in rabbits.

  10. Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial.

    Science.gov (United States)

    Ocak, Tarik; Tekin, Erdal; Basturk, Mustafa; Duran, Arif; Serinken, Mustafa; Emet, Mucahit

    2016-11-01

    There is a lack of specificity of the analgesic agents used to treat headache and underlying acute carbon monoxide poisoning. To compare effectiveness of "oxygen alone" vs "metoclopramide plus oxygen" vs "metamizole plus oxygen" therapy in treating carbon monoxide-induced headache. A prospective, multicenter, double-blind, controlled trial. Three emergency departments in Turkey. Adult carbon monoxide poisoning patients with headache. A total of 117 carbon monoxide-intoxicated patients with headache were randomized into 3 groups and assessed at baseline, 30 minutes, 90 minutes, and 4 hours. The primary outcome was patient-reported improvement rates for headache. Secondary end points included nausea, need for rescue medication during treatment, and reduction in carboxyhemoglobin levels. During observation, there was no statistical difference between drug type and visual analog scale score change at 30 minutes, 90 minutes, or 4 hours, for either headache or nausea. No rescue medication was needed during the study period. The reduction in carboxyhemoglobin levels did not differ among the 3 groups. The use of "oxygen alone" is as efficacious as "oxygen plus metoclopramide" or "oxygen plus metamizole sodium" in the treatment of carbon monoxide-induced headache. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  12. Exhaled carbon monoxide: a non-invasive biomarker of short-term exposure to outdoor air pollution

    Directory of Open Access Journals (Sweden)

    Herve Lawin

    2017-04-01

    Full Text Available Abstract Background In urban settings of Africa with rapidly increasing population, traffic-related air pollution is a major contributor to outdoor air pollution (OAP. Although OAP has been identified as a leading cause of global morbidity and mortality, there is however, lack of a simple biomarker to assess levels of exposure to OAP in resource-poor settings. This study evaluated the role of exhaled carbon monoxide (exhCO as a potential biomarker of exposure to ambient carbon monoxide (ambCO from OAP. Methods This was a descriptive study conducted among male commercial motorcycle riders in Cotonou – the economic capital of Benin. The participants’ AmbCO was measured using a portable carbon monoxide (CO data logger for 8 h during the period of their shift. ExhCO was measured just before and immediately after their shift (8-h Participants were asked not to cook or to smoke during the day of the measurements. Linear regression analysis was used to assess the association between ambCO and exhCO for the last 2, 4 and 6 h of their shift. Results Of 170 participants who completed the study, their mean ± SD age was 42.2 ± 8.4 years, and their mean ± SD daily income was 7.3 ± 2.7$. Also, 95% of the participants’ used solid fuels for cooking and only 2% had ever smoked. Average exhCO increased by 5.1 ppm at the end of the shift (p = 0.004. Post-shift exhCO was significantly associated to ambCO, this association was strongest for the last 2 h of OAP exposure before exhCO measurement (β = 0.34, p < 0.001. Conclusion ExhCO level was associated with recent exposure to ambCO from OAP with measurable increase after 8 h of exposure. These findings suggest that ExhCO may be a potential biomarker of short-term exposure to OAP.

  13. Cyclic process for producing methane from carbon monoxide with heat removal

    Science.gov (United States)

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  14. Digit and letter alexia in carbon monoxide poisoning

    Institute of Scientific and Technical Information of China (English)

    Qingyu Shen; Xiaoming Rong; Rui Pan; Ying Peng; Wei Peng; Yamei Tang

    2012-01-01

    This study examined a 24-year-old patient with delayed encephalopathy, who was admitted to hospital with complaints of headache and visual impairment 1 week after acute carbon monoxide poisoning. The results of a visual field assessment, electroencephalography and head magnetic resonance imaging indicated damage to the cerebral cortex. After a 2-week treatment period, the patient had recovered from the visual impairment, but exhibited digit- and letter-reading difficulty. The Chinese aphasia battery and the number and letter battery supplement were conducted. The results revealed that the patient exhibited digit and letter alexia, while the ability to read Chinese characters was preserved. In contrast, the patient exhibited a deficit in Chinese character writing, while number and letter writing remained intact. Following treatment, reading and writing ability was improved and electroencephalographic abnormalities were ameliorated. Overall, our experimental findings demonstrated that delayed encephalopathy following acute carbon monoxide poisoning was characterized by digit and letter alexia.

  15. Electron stimulated molecular desorption of a non-evaporable Zr-V-Fe alloy getter at room temperature

    CERN Document Server

    Le Pimpec, Frederic; Laurent, Jean Michel

    2002-01-01

    Electron stimulated molecular desorption (ESD) from a non-evaporable getters (NEG) St 707 registered trademark (SAES Getters trademark ) sample after conditioning and after saturation with isotopic carbon monoxide (cf. nomenclature in Handbook of Chemistry and Physics, CRC Press, 1994), **1**3C**1**8O, has been studied on a laboratory setup. Measurements were performed using an electron beam of 300 eV kinetic energy, with an average electron intensity of 1.6 multiplied by 10**1**5 electrons s**-**1. The electrons were impinging on the 15 cm **2 target surface at perpendicular incidence. It is found that the desorption yields eta (molecules/electron) of the characteristic gases in an UHV system (hydrogen, methane, water, carbon monoxide, carbon dioxide) for a fully activated NEG as well as for a NEG fully saturated with **1**3C**1**8O are lower than for OFHC copper baked at 120 degree C. A small fraction only of the gas which is required to saturate the getter surface can be re-desorbed and thus appears to be ...

  16. The indigenous Sea Gypsy divers of Thailand's west coast: measurement of carbon monoxide in the breathing air.

    Science.gov (United States)

    Gold, D; Geater, A; Aiyarak, S; Juengpraert, W

    1999-07-01

    Approximately 400 indigenous divers live and work on Thailand's west coast. They dive with surface supplied air from primitive compressor units mounted on open boats which measure from seven to 11 meters in length. It was suspected that carbon monoxide was present in the breathing air of at least the gasoline-driven compressor units. To determine the presence of carbon monoxide gas in the breathing air, compressed air from the compressor was pumped through the diver air supply hose through a plenum (monitoring) chamber established on the boat. After a compressor warm-up of 15 minutes, the diving air was measured with the boat at eight different bearings to the wind, each 45 degrees apart at intervals of five minutes. Three of the four gasoline-driven compressor units tested showed presence of carbon monoxide in the breathing air. One diesel-driven unit showed a very low concentration of carbon monoxide (3-4 ppm) and six diesel-driven units showed no detectable carbon monoxide. Although not tested, diesel exhaust emissions could also enter the breathing air by the same route. A locally made modification to the compressor air intake was designed and successfully tested on one gasoline-driven compressor unit. An information sheet on the hazards of carbon monoxide as well as on the modification has been developed for distribution among the villages.

  17. Ethylene and Carbon Monoxide Production by Septoria musiva

    Science.gov (United States)

    S. Brown-Skrobot; L. R. Brown; T. H. Filer

    1984-01-01

    An investigation into the mechanism by which Septoria musiva causes the premature defoliation of cottonwood trees was undertaken. Gas-chromatograpic analysis of the atmosphere overlying the original culture indicated that this fungus produced significant quantities of ethylene and carbon monoxide. Subcultures failed to produce either gas on a variety...

  18. Pathways and bioenergetics of anaerobic carbon monoxide fermentation

    NARCIS (Netherlands)

    Diender, Martijn; Stams, Fons; Machado de Sousa, Diana

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the

  19. Interactions of carbon monoxide and hemoglobin at high altitude

    Energy Technology Data Exchange (ETDEWEB)

    Collier, C.R. (Univ. of Southern California Medical Center, Los Angeles); Goldsmith, J.R.

    1983-01-01

    The health risks to U.S. populations who are exposed to ambient carbon monoxide and live at altitudes (such as Denver, Salt Lake City, and Albuquerque) were evaluated using a set of mathematical models. The assumption that a given increase in carboxyhemoglobin would require a more stringent volumetric air quality standard was tested. The results using the model predict that the 8-h or 1-h standards adopted for sea level condition need not be altered to protect individuals against health risks at altitude, if the standards are in volumetric terms. They would need to be reduced if the standards are left in gravimetric terms. If the guideline is to be based on a given decrement of oxygen tension, many other variables must be specified, but expected differences in ambient carbon monoxide have a small impact compared to the effect of altitude itself.

  20. One-electron theory of metals

    International Nuclear Information System (INIS)

    Skriver, H.L.

    1984-12-01

    The work described in the report and the 16 accompanying publications is based upon a one-electron theory obtained within the local approximation to density-functional theory, and deals with the ground state of metals as obtained from self-consistent electronic-structure calculations performed by means of the Linear Muffin-Tin Orbital (LMTO) method. It has been the goal of the work to establish how well this one-electron approach describes physical properties such as the crystal structures of the transition metals, the structural phase transitions in the alkali, alkaline earth, and rare earth metals, and the localization of 3d, 4f, and 5f electrons in the 3d metal monoxides, the light lanthanides, and the actinides, respectively, as well as the cohesive properties of metals in general. (orig.)

  1. Accidental carbon monoxide poisoning during yagya for faith healing--a case report.

    Science.gov (United States)

    Behera, C; Millo, T M; Jaiswal, A; Dogra, T D

    2013-03-01

    A 20-year-old female and a 45-year-old male were found lying dead on the floor with frothand vomitus stain present over mouth, nose and face in a closed room. An earthen bowl with incomplete burnt woods, flowers, food materials, agarbati, etc, was also found lying near the body of the two deceased. The cause of death, established by autopsy and toxicological examination was carbon monoxide poisoning in both victims. The source of carbon monoxide was incomplete burnt woods used for yagya during puja (a faith healing practice) for bearing children.

  2. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Science.gov (United States)

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  3. Model of e-learning with electronic educational resources of new generation

    OpenAIRE

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  4. [Carbon monoxide poisoning by a heating system].

    Science.gov (United States)

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  5. Absorption of nicotine and carbon monoxide from passive smoking under natural conditions of exposure.

    Science.gov (United States)

    Jarvis, M J; Russell, M A; Feyerabend, C

    1983-01-01

    Seven non-smokers were exposed to tobacco smoke under natural conditions for two hours in a public house. Measures of nicotine and cotinine in plasma, saliva, and urine and expired air carbon monoxide all showed reliable increases. The concentrations of carbon monoxide and nicotine after exposure averaged 15.7% and 7.5% respectively of the values found in heavy smokers. Although the increase in expired air carbon monoxide of 5.9 ppm was similar to increases in smokers after a single cigarette, the amount of nicotine absorbed was between a tenth and a third of the amount taken in from one cigarette. Since this represented a relatively extreme acute natural exposure, any health risks of passive smoking probably depend less on quantitative factors than on qualitative differences between sidestream and mainstream smoke. PMID:6648864

  6. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  7. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  8. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    Science.gov (United States)

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  9. A comparison of hydrogen-bonded and van der Waals isomers of phenolṡṡnitrogen and phenolṡṡcarbon monoxide: An ab initio study

    Science.gov (United States)

    Chapman, Darren M.; Müller-Dethlefs, Klaus; Peel, J. Barrie

    1999-08-01

    The hydrogen-bonded and van der Waals isomers of phenolṡṡnitrogen and phenolṡṡcarbon monoxide in their neutral electronic (S0) and cation ground state (D0) were studied using ab initio HF/6-31G*, MP2/6-31G*, and B3LYP/6-31G* methods. The hydrogen-bonded isomers have the ligand bound via the hydroxyl group of the phenol ring, while the van der Waals isomers studied have the ligand located above the aromatic ring. For both complexes, the hydrogen-bonded isomer was found to be the most stable form for both the S0 and the D0 states. For phenolṡṡcarbon monoxide, twice as many isomers as compared to phenolṡṡnitrogen were found. The hydrogen-bonded isomer with the carbon end bonded to the hydroxyl group was the most stable structure for both the S0 and the D0 states.

  10. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  11. Acute wood or coal exposure with carbon monoxide intoxication induces sister chromatid exchange

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, S.; Vatansever, S.; Cefle, K.; Palanduz, S.; Guler, K.; Erten, N.; Erk, O.; Karan, M.A.; Tascioglu, C. [University of Istanbul, Istanbul (Turkey). Istanbul Faculty of Medicine

    2002-07-01

    The object of this study was to investigate the genotoxic effect of acute overexposure to combustion products originating from coal or wood stoves in patients presenting with acute carbon monoxide intoxication. The authors analyzed the frequency of sister chromatid exchange and the carboxyhemoglobin concentration in 20 consecutive patients without a history of smoking or drug use who had been treated in the Emergency Care Unit of Istanbul Medical Faculty due to acute carbon monoxide intoxication. All of these cases were domestic accidents due to dysfunctioning coal or wood stoves. The results were compared with a control group of 20 nonsmoking, nondrug-using healthy individuals matched for age, sex, and absence of other chemical exposure. It was concluded that acute exposure to combustion products of wood or coal is genotoxic to DNA. Potential causes of genotoxicity include known mutagenic compounds present in coal or wood smoke and ash, oxygen radicals formed during combustion, as well as hypoxic and reperfusion injury mechanisms initiated by carbon monoxide intoxication.

  12. Monoxides of small terbium clusters: A density functional theory investigation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, G. L.; Yuan, H. K., E-mail: yhk10@swu.edu.cn; Chen, H.; Kuang, A. L.; Li, Y.; Wang, J. Z.; Chen, J. [School of Physical Science and Technology, Southwest University, Chongqing 400715 (China)

    2014-12-28

    To investigate the effect of oxygen atom on the geometrical structures, electronic, and magnetic properties of small terbium clusters, we carried out the first-principles calculations on Tb{sub n}O (n = 1-14) clusters. The capping of an oxygen atom on one trigonal-facet of Tb{sub n} structures is always favored energetically, which can significantly improve the structural stability. The far-infrared vibrational spectroscopies are found to be different from those of corresponding bare clusters, providing a distinct signal to detect the characteristic structures of Tb{sub n}O clusters. The primary effect of oxygen atom on magnetic properties is to change the magnetic orderings among Tb atoms and to reduce small of local magnetic moments of the O-coordinated Tb atoms, both of which serve as the key reasons for the experimental magnetic evolution of an oscillating behavior. These calculations are consistent with, and help to account for, the experimentally observed magnetic properties of monoxide Tb{sub n}O clusters [C. N. Van Dijk et al., J. Appl. Phys. 107, 09B526 (2010)].

  13. Influence of cation size and surface coverage upon the infrared spectrum of carbon monoxide

    OpenAIRE

    Huang, Jimin

    1991-01-01

    Adsorbed carbon monoxide is utilized as a double layer probe molecule because of its strong absorption in infrared region and because of the high sensitivity of the carbon-oxygen bond to changes in the environment local to the electrode surface. Potential Difference Infrared Spectroscopy was used to investigate the structural behavior of CO adsorbed on a platinum electrode. Carbon monoxide was found to be exclusively linear-bonded on platinum electrode in the presence of tetran...

  14. Catalytic hydrogenation of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Wayland, B.B.

    1992-12-01

    This project is focused on developing strategies to accomplish the reduction and hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. Our approaches to this issue are based on the recognition that rhodium macrocycles have unusually favorable thermodynamic values for producing a series of intermediate implicated in the catalytic hydrogenation of CO. Observations of metalloformyl complexes produced by reactions of H{sub 2} and CO, and reductive coupling of CO to form metallo {alpha}-diketone species have suggested a multiplicity of routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in constructing energy profiles for a variety of potential pathways, and these schemes are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Variation of the electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Emerging knowledge of the factors that contribute to M-H, M-C and M-O bond enthalpies is directing the search for ligand arrays that will expand the range of metal species that have favorable thermodynamic parameters to produce the primary intermediates for CO hydrogenation. Studies of rhodium complexes are being extended to non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics. Multifunctional catalyst systems designed to couple the ability of rhodium complexes to produce formyl and diketone intermediates with a second catalyst that hydrogenates these imtermediates are promising approaches to accomplish CO hydrogenation at mild conditions.

  15. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  16. Characteristics of exogenous carbon monoxide deliveries

    Directory of Open Access Journals (Sweden)

    Hui-jun Hu

    2016-01-01

    Full Text Available Carbon monoxide (CO has long been considered an environmental pollutant and a poison. Exogenous exposure to amounts of CO beyond the physiologic level of the body can result in a protective or adaptive response. However, as a gasotransmitter, endogenous CO is important for multiple physiologic functions. To date, at least seven distinct methods of delivering CO have been utilized in animal and clinical studies. In this mini-review, we summarize the exogenous CO delivery methods and compare their advantages and disadvantages.

  17. Carbon monoxide oxidation using Zn-Cu-Ti hydrotalcite-derived ...

    Indian Academy of Sciences (India)

    Multioxide catalysts of zinc, copper and titanium with different ratios obtained from layered double hydroxide (LDH) precursors were used in the oxidation of carbon monoxide. The catalysts were characterized by energy-dispersive X-ray spectrometry, X-ray diffraction, thermal analyses (TG, DTG and DTA) and scanning ...

  18. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  19. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    Science.gov (United States)

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  20. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008; Campagne de prevention des intoxications au monoxyde de carbone : automne-hiver 2007-2008

    Energy Technology Data Exchange (ETDEWEB)

    Lefebvre, B.; Chabot, L.; Gratton, J. [Direction de sante publique de Montreal, Montreal, PQ (Canada); Lacoursiere, D. [Quebec Ministere de la Sante et des Services sociaux du Quebec, Quebec, PQ (Canada)

    2009-07-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  1. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Directory of Open Access Journals (Sweden)

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  2. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  3. Sensorineural Hearing Loss following Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Joseph P. Pillion

    2012-01-01

    Full Text Available A case study is presented of a 17-year-old male who sustained an anoxic brain injury and sensorineural hearing loss secondary to carbon monoxide poisoning. Audiological data is presented showing a slightly asymmetrical hearing loss of sensorineural origin and mild-to-severe degree for both ears. Word recognition performance was fair to poor bilaterally for speech presented at normal conversational levels in quiet. Management considerations of the hearing loss are discussed.

  4. Photodissociation of the carbon monoxide dication in the {sup 3}Σ{sup −} manifold: Quantum control simulation towards the C{sup 2+} + O channel

    Energy Technology Data Exchange (ETDEWEB)

    Vranckx, S. [Service de Chimie Quantique et Photophysique, Université Libre de Bruxelles (ULB), CP 160/09, B-1050 Brussels (Belgium); Laboratoire de Chimie Physique (UMR 8000), Université Paris-Sud, Orsay 91405 (France); Loreau, J.; Vaeck, N. [Service de Chimie Quantique et Photophysique, Université Libre de Bruxelles (ULB), CP 160/09, B-1050 Brussels (Belgium); Meier, C. [Laboratoire Collisions Agrégats Réactivité, UMR 5589, IRSAMC, Université Toulouse III Paul Sabatier, Bât. 3R1b4, Toulouse (France); Desouter-Lecomte, M., E-mail: michele.desouter-lecomte@u-psud.fr [Laboratoire de Chimie Physique (UMR 8000), Univ. Paris Sud, Université Paris-Saclay, Orsay 91405 (France); Département de Chimie, B6c Université de Liège, Sart Tilman, 4000 Liège (Belgium)

    2015-10-28

    The photodissociation and laser assisted dissociation of the carbon monoxide dication X{sup 3}Π CO{sup 2+} into the {sup 3}Σ{sup −} states are investigated. Ab initio electronic structure calculations of the adiabatic potential energy curves, radial nonadiabatic couplings, and dipole moments for the X {sup 3}Π state are performed for 13 excited {sup 3}Σ{sup −} states of CO{sup 2+}. The photodissociation cross section, calculated by time-dependent methods, shows that the C{sup +} + O{sup +} channels dominate the process in the studied energy range. The carbon monoxide dication CO{sup 2+} is an interesting candidate for control because it can be produced in a single, long lived, v = 0 vibrational state due to the instability of all the other excited vibrational states of the ground {sup 3}Π electronic state. In a spectral range of about 25 eV, perpendicular transition dipoles couple this {sup 3}Π state to a manifold of {sup 3}Σ{sup −} excited states leading to numerous C{sup +} + O{sup +} channels and a single C{sup 2+} + O channel. This unique channel is used as target for control calculations using local control theory. We illustrate the efficiency of this method in order to find a tailored electric field driving the photodissociation in a manifold of strongly interacting electronic states. The selected local pulses are then concatenated in a sequence inspired by the “laser distillation” strategy. Finally, the local pulse is compared with optimal control theory.

  5. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Science.gov (United States)

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  6. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Electron Capture in Proton Collisions with CO.

    Science.gov (United States)

    Stancil, P. C.; Schultz, D. R.; Kimura, M.; Gu, J.-P.; Hirsch, G.; Buenker, R. J.; Li, Y.

    1999-10-01

    Electron capture by protons following collisions with carbon monoxide is studied with a variety of theoretical approaches including quantal and semiclassical molecular-orbital close-coupling (MOCC) and classical trajectory Monte Carlo (CTMC) techniques. The MOCC treatments utilize potential surfaces and couplings computed for a range of H^+-CO orientation angles and C-O separations. Results including integral, differential, electronic state-selective, and vibrational state-selective cross sections will be presented for low- to intermediate-energies. Comparison with experiment will be made where possible and the relevance of the reaction in astrophysics and atmospheric physics will be discussed.

  8. Cumulative exposure to carbon monoxide during the day

    Energy Technology Data Exchange (ETDEWEB)

    Joumard, R. (INRETS, 69 - Bron (FR))

    The carbon monoxide, CO, has the advantage of being very easily and accurately measured under various conditions. In addition, it allows the translation of CO concentrations into their biological effects. The cumulative CO exposure should be considered according to current environment conditions during a given period of life, e.g. the day. In addition, the translation of concentrations and exposure times of CO fixed on blood haemoglobine (carboxyhaemoglobine) depends on physiological factors such as age, size, sex, or physical activity. This paper gives some examples of CO exposure translated into curves of carboxyhaemoglobine: case of 92 persons whose schedule was studied in details, of customs officers whose exposure was measured during one week, or other theoretical cases. In all the cases studied, smoking is by far the first factor of pollution by carbon monoxide. If not considering this case, the CO contents observed are preoccupying for sensitive subjects (in particular children) only in very rare cases. Furthermore, this approach allows the assessment of maximal allowable concentrations during specific exposures (work, e.g. in a tunnel) by integrating them into normal life conditions and population current exposure.

  9. LETTER TO THE EDITOR: Observation of photo-double ionization of carbon monoxide below the adiabatic double-ionization potential by threshold-photoelectron - photoelectron coincidence spectroscopy

    Science.gov (United States)

    Thompson, David B.; Dawber, Grant; Gulley, Nicola; MacDonald, Michael A.; King, George C.

    1997-03-01

    The production of 0953-4075/30/5/004/img8 and 0953-4075/30/5/004/img9 ion pairs in carbon monoxide at photon energies below the adiabatic double-ionization threshold of 41.25 eV has been probed in a threshold-photoelectron - photoelectron coincidence (TPEPECO) experiment using tunable VUV radiation and a sensitive electron spectrometer. The TPEPECO spectra provide evidence of 0953-4075/30/5/004/img10 production that does not involve creation and dissociation of a molecular dication, but instead results from complete dissociation of a molecular cation followed by autoionization of the atomic oxygen fragment. Furthermore, an electron - electron coincidence signal has been detected at photon energies as low as 36.5 eV, well below the previously measured onset for 0953-4075/30/5/004/img10 production.

  10. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  11. Carbon monoxide - hydrogen combustion characteristics in severe accident containment conditions. Final report

    International Nuclear Information System (INIS)

    2000-03-01

    Carbon monoxide can be produced in severe accidents from interaction of ex-vessel molten core with concrete. Depending on the particular core-melt scenario, the type of concrete and geometric factors affecting the interaction, the quantities of carbon monoxide produced can vary widely, up to several volume percent in the containment. Carbon monoxide is a combustible gas. The carbon monoxide thus produced is in addition to the hydrogen produced by metal-water reactions and by radiolysis, and represents a possibly significant contribution to the combustible gas inventory in the containment. Assessment of possible accident loads to containment thus requires knowledge of the combustion properties of both CO and H 2 in the containment atmosphere. Extensive studies have been carried out and are still continuing in the nuclear industry to assess the threat of hydrogen in a severe reactor accident. However the contribution of carbon monoxide to the combustion threat has received less attention. Assessment of scenarios involving ex-vessel interactions require additional attention to the potential contribution of carbon monoxide to combustion loads in containment, as well as the effectiveness of mitigation measures designed for hydrogen to effectively deal with particular aspects of carbon monoxide. The topic of core-concrete interactions has been extensively studied; for more complete background on the issue and on the physical/thermal-hydraulics phenomena involved, the reader is referred to Proceedings of CSNI Specialists Meetings (Ritzman, 1987; Alsmeyer, 1992) and a State-of-Art Report (European Commission, 1995). The exact amount of carbon monoxide present in a reactor pit or in various compartments (or rooms) in a containment building is specific to the type of concrete and the accident scenario considered. Generally, concrete containing limestone and sand have a high percentage of CaCO 3 . Appendix A provides an example of results of estimates of CO and CO 2

  12. Pathology of carbon monoxide poisoning in two cats.

    Science.gov (United States)

    Sobhakumari, Arya; Poppenga, Robert H; Pesavento, J Brad; Uzal, Francisco A

    2018-03-05

    Carbon monoxide (CO), a common cause of poisoning in human beings has also been implicated in the death of animals. Though there are multiple studies on CO poisoning and relevant lethal blood COHb concentrations in humans, there are no reliable reports of diagnostic lethal carboxyhemoglobin percentage of saturation (COHb%) in cats. Additionally, due to shared housing environments, exposures to companion animals can be a surrogate for lethal exposures in human beings and provide valuable information in concurrent forensic investigations. Two adult Singapura brown ticked cats were submitted to the California Animal Health and Food Safety Laboratory (CAHFS) for necropsy and diagnostic work-up. These animals were found dead along with their two deceased owners. Similar lesions were observed in both cats. At necropsy, gross lesions consisted of multifocal, large, irregular, bright red spots on the skin of the abdomen and the inner surface of ear pinnae, bright red muscles and blood. The carcasses, and tissues fixed in formalin retained the bright red discoloration for up to two weeks. Microscopic lesions included diffuse pulmonary congestion and edema, and multifocal intense basophilia of cardiomyocytes mostly affecting whole fibers or occasionally a portion of the fiber. Based on the clinical history,gross and microscopic changes, cyanide or carbon monoxide poisoning was suspected. Blood samples analyzed for carbon monoxide showed 57 and 41% carboxyhemoglobin COHb%. Muscle samples were negative for cyanide. There are no established reference values for lethal COHb concentration in cats. The COHb % values detected in this case which fell within the lethal range reported for other species, along with the gross lesions and unique histological findings in the heart suggest a helpful criteria for diagnosis of CO intoxication associated death in cats. This case demonstrates that since pets share the same environment as human beings and often are a part of their activities

  13. Characteristic and Prediction of Carbon Monoxide Concentration using Time Series Analysis in Selected Urban Area in Malaysia

    Directory of Open Access Journals (Sweden)

    Abdul Hamid Hazrul

    2017-01-01

    Full Text Available Carbon monoxide (CO is a poisonous, colorless, odourless and tasteless gas. The main source of carbon monoxide is from motor vehicles and carbon monoxide levels in residential areas closely reflect the traffic density. Prediction of carbon monoxide is important to give an early warning to sufferer of respiratory problems and also can help the related authorities to be more prepared to prevent and take suitable action to overcome the problem. This research was carried out using secondary data from Department of Environment Malaysia from 2013 to 2014. The main objectives of this research is to understand the characteristic of CO concentration and also to find the most suitable time series model to predict the CO concentration in Bachang, Melaka and Kuala Terengganu. Based on the lowest AIC value and several error measure, the results show that ARMA (1,1 is the most appropriate model to predict CO concentration level in Bachang, Melaka while ARMA (1,2 is the most suitable model with smallest error to predict the CO concentration level for residential area in Kuala Terengganu.

  14. Carbon dioxide elimination and regeneration of resources in a microwave plasma torch.

    Science.gov (United States)

    Uhm, Han S; Kwak, Hyoung S; Hong, Yong C

    2016-04-01

    Carbon dioxide gas as a working gas produces a stable plasma-torch by making use of 2.45 GHz microwaves. The temperature of the torch flame is measured by making use of optical spectroscopy and a thermocouple device. Two distinctive regions are exhibited, a bright, whitish region of a high-temperature zone and a bluish, dimmer region of a relatively low-temperature zone. The bright, whitish region is a typical torch based on plasma species where an analytical investigation indicates dissociation of a substantial fraction of carbon dioxide molecules, forming carbon monoxides and oxygen atoms. The emission profiles of the oxygen atoms and the carbon monoxide molecules confirm the theoretical predictions of carbon dioxide disintegration in the torch. Various hydrocarbon materials may be introduced into the carbon dioxide torch, regenerating new resources and reducing carbon dioxide concentration in the torch. As an example, coal powders in the carbon dioxide torch are converted into carbon monoxide according to the reaction of CO2 + C → 2CO, reducing a substantial amount of carbon dioxide concentration in the torch. In this regards, the microwave plasma torch may be one of the best ways of converting the carbon dioxides into useful new materials. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  16. Synthesis of ZnMn2O4 Nanoparticles by a Microwave-Assisted Colloidal Method and their Evaluation as a Gas Sensor of Propane and Carbon Monoxide

    Directory of Open Access Journals (Sweden)

    Juan Pablo Morán-Lázaro

    2018-02-01

    Full Text Available Spinel-type ZnMn2O4 nanoparticles were synthesized via a simple and inexpensive microwave-assisted colloidal route. Structural studies by X-ray diffraction showed that a spinel crystal phase of ZnMn2O4 was obtained at a calcination temperature of 500 °C, which was confirmed by Raman and UV-vis characterizations. Spinel-type ZnMn2O4 nanoparticles with a size of 41 nm were identified by transmission electron microscopy. Pellet-type sensors were fabricated using ZnMn2O4 nanoparticles as sensing material. Sensing measurements were performed by exposing the sensor to different concentrations of propane or carbon monoxide at temperatures in the range from 100 to 300 °C. Measurements performed at an operating temperature of 300 °C revealed a good response to 500 ppm of propane and 300 ppm of carbon monoxide. Hence, ZnMn2O4 nanoparticles possess a promising potential in the gas sensors field.

  17. Carbon monoxide toxicity. January 1978-March 1989 (Citations from the Life Sciences Collection data base). Report for January 1978-March 1989

    Energy Technology Data Exchange (ETDEWEB)

    1989-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 221 citations, 19 of which are new entries to the previous edition.)

  18. Carbon monoxide gas sensing using zinc oxide deposited by successive ionic layer adhesion and reaction

    Science.gov (United States)

    Florido, E. A.; Dagaas, N. A. C.

    2017-05-01

    This study was aimed to determine the carbon monoxide (CO) gas sensing capability of zinc oxide (ZnO) film fabricated by successive ionic layer adsorption and reaction (SILAR) on glass substrate. Films consisting of a mixture of flower-like clusters of ZnO nanorods and nanowires were observed using scanning electron microscopy (SEM). Current-voltage characterization of the samples showed an average resistivity of 13.0 Ω-m. Carbon monoxide gas was synthesized by mixing the required amount of formic acid and excess sulfuric acid to produce CO gas concentrations of 100, 200, 300, 400, and 500 parts per million (ppm) v/v with five trials for each concentration. Two sets of data were obtained. One set consisted of the voltage response of the single film sensor while the other set were obtained from the double film sensor. The voltage response for the single film sensor and the double film sensor showed an average sensitivity of 0.0038 volts per ppm and 0.0024 volts per ppm, respectively. The concentration the single film can detect with a 2V output is 526 ppm while the double film sensor can detect up to 833 ppm with a 2V output. This shows that using the double film sensor is advantageous compared to single film sensor, because of its higher concentration range due to the larger surface area for the gas to interact. Moreover, the measured average resistance for the single film sensor was 10 MΩ while for the double film sensor the average resistance was 5 MΩ.

  19. Spectroscopic investigations of high-power laser-induced dielectric breakdown in gas mixtures containing carbon monoxide.

    Science.gov (United States)

    Civis, Svatopluk; Babánková, Dagmar; Cihelka, Jaroslav; Sazama, Petr; Juha, Libor

    2008-08-07

    Large-scale plasma was created in gas mixtures containing carbon monoxide by high-power laser-induced dielectric breakdown (LIDB). The composition of the mixtures used corresponded to a cometary and/or meteoritic impact into the Earth's early atmosphere. A multiple-centimeter-sized fireball was created by focusing a single 85 J, 450 ps near-infrared laser pulse into the center of a 15 L gas cell. The excited reaction intermediates that formed in various stages of the LIDB plasma chemical evolution were investigated by optical emission spectroscopy (OES) with temporal resolution. Special attention was paid to any OES signs of molecular ions. However, carbon monoxide cations were registered only if their production was enhanced by Penning ionization, i.e., excess He was added to the CO. The chemical consequences of laser-produced plasma generation in a CO-N 2-H 2O mixture were investigated using high resolution Fourier-transform infrared absorption spectroscopy (FTIR) and gas chromatography (GC). Several simple inorganic and organic compounds were identified in the reaction mixture exposed to ten laser sparks. H 2 (18)O was used to avoid possible contamination. The large laser spark triggered more complex reactivity originating in carbon monoxide than expected, when taking into account the strong triple bond of carbon monoxide causing typically inefficient dissociation of this molecule in electrical discharges.

  20. Carbon Monoxide Poisoning: Death on Mount McKinley,

    Science.gov (United States)

    1987-05-08

    Additionally, studies by Astrup(5) and Thomas(6) have reported decreased erythrocytic 2, 3- diphosphoglycerate (2, 3-DPG) concentrations with acute...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia .(9...Astrup P: Intraerythrocytic 2,3- diphosphoglycerate and carbon monoxide exposure. Ann NY Acad Sci 1970;174:252-254. 6. Thomas MF, Penny DG: Hematologic

  1. Natural clinoptilolite exchanged with iron: characterization and catalytic activity in nitrogen monoxide reduction

    Directory of Open Access Journals (Sweden)

    Daria Tito-Ferro

    2016-12-01

    Full Text Available The aim of this work was to characterize the natural clinoptilolite from Tasajeras deposit, Cuba, modified by hydrothermal ion-exchange with solutions of iron (II sulfate and iron (III nitrate in acid medium. Besides this, its catalytic activity to reduce nitrogen monoxide with carbon monoxide/propene in the presence of oxygen was evaluated. The characterization was performed by Mössbauer and UV-Vis diffuse reflectance spectroscopies and adsorption measurements. The obtained results lead to conclude that in exchanged samples, incorporated divalent and trivalent irons are found in octahedral coordination. Both irons should be mainly in cationic extra-framework positions inside clinoptilolite channels as charge compensating cations, and also as iron oxy-hydroxides resulting from limited hydrolysis of these cations. The iron (III exchanged samples has a larger amount of iron oxy-hydroxides agglomerates. The iron (II exchanged samples have additionally iron (II sulfate adsorbed. The catalytic activity in the nitrogen monoxide reduction is higher in the exchanged zeolites than starting. Among all samples, those exchanged of iron (II has the higher catalytic activity. This lead to outline that, main catalytically active centers are associated with divalent iron.

  2. Carbon Monoxide Poisoning in a Child: A Case Report | Asani ...

    African Journals Online (AJOL)

    The exact incidence of carbon monoxide (CO) poisoning in Nigeria is unknown. Globally, CO poisoning is frequently unrecognized and under-reported since the clinical presentation is relatively non-specific. The circumstances usually involve an unsuspected increase of CO in an enclosed environment. We present the ...

  3. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  4. Theoretical studies on the catalytic oxidation of carbon monoxide on nickel clusters

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, A.K.; Kojima, I.; Miyazaki, E.

    1986-01-01

    Complete neglect of differential overlap (CNDO) molecular orbital calculations using the method of Anno and Sakai for the evaluation of the valence orbital ionization potential (VOIP) were performed with the aim of studying the oxidation of carbon monoxide on nickel clusters. A cluster surface was assumed to be preadsorbed with oxygen and the variation of various bond energies with the approach of a carbon monoxide molecule was studied for different models. Various possibilities for the reaction path are discussed in the light of the theoretical findings and it is suggested that at a low coverage of oxygen the reaction may follow a Langmuir-Hinshelwood path, whereas at a high coverage, an Eley-Rideal path might be more probable. 55 references, 13 figures.

  5. Hydrogen Oxidation on Gas Diffusion Electrodes for Phosphoric Acid Fuel Cells in the Presence of Carbon Monoxide and Oxygen

    DEFF Research Database (Denmark)

    Gang, Xiao; Li, Qingfeng; Hjuler, Hans Aage

    1995-01-01

    Hydrogen oxidation has been studied on a carbon-supported platinum gas diffusion electrode in a phosphoric acidelectrolyte in the presence of carbon monoxide and oxygen in the feed gas. The poisoning effect of carbon monoxide presentin the feed gas was measured in the temperature range from 80...... to 150°C. It was found that throughout the temperaturerange, the potential loss due to the CO poisoning can be reduced to a great extent by the injection of small amounts ofgaseous oxygen into the hydrogen gas containing carbon monoxide. By adding 5 volume percent (v/o) oxygen, an almost...

  6. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  7. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    International Nuclear Information System (INIS)

    Tong, Liping; Yu, K.N.; Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi; Han, Wei

    2014-01-01

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy

  8. Low concentration of exogenous carbon monoxide protects mammalian cells against proliferation induced by radiation-induced bystander effect

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Liping [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Yu, K.N. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong (Hong Kong); Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Bao, Lingzhi; Wu, Wenqing; Wang, Hongzhi [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Han, Wei, E-mail: hanw@hfcas.cn [Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China)

    2014-01-15

    Highlights: • We show the possibility of modulate proliferation induced by radiation-induced bystander effect with low concentration carbon monoxide. • Carbon monoxide inhibited proliferation via modulating the transforming growth factor β1 (TGF-β1)/nitric oxide (NO) signaling pathway. • Exogenous carbon monoxide has potential application in clinical radiotherapy. - Abstract: Radiation-induced bystander effect (RIBE) has been proposed to have tight relationship with the irradiation-caused secondary cancers beyond the irradiation-treated area after radiotherapy. Our previous studies demonstrated a protective effect of low concentration carbon monoxide (CO) on the genotoxicity of RIBE after α-particle irradiation. In the present work, a significant inhibitory effect of low-dose exogenous CO, generated by tricarbonyldichlororuthenium (II) dimer [CO-releasing molecule (CORM-2)], on both RIBE-induced proliferation and chromosome aberration was observed. Further studies on the mechanism revealed that the transforming growth factor β1/nitric oxide (NO) signaling pathway, which mediated RIBE signaling transduction, could be modulated by CO involved in the protective effects. Considering the potential of exogenous CO in clinical applications and its protective effect on RIBE, the present work aims to provide a foundation for potential application of CO in radiotherapy.

  9. Acute Compartment Syndrome Which Causes Rhabdomyolysis by Carbon Monoxide Poisoning and Sciatic Nerve Injury Associated with It: A Case Report.

    Science.gov (United States)

    Ji, Jung-Woo

    2017-09-01

    Rhabdomyolysis is most frequently caused by soft tissue injury with trauma to the extremities. Non-traumatic rhabdomyolysis may be caused by alcohol or drug abuse, infection, collagen disease, or intensive exercise, but incidence is low. In particular, rhabdomyolysis resulting from carbon monoxide poisoning is especially rare. If caught before death, carbon monoxide poisoning has been shown to cause severe muscle necrosis and severe muscle damage leading to acute renal failure. In cases of carbon-monoxide-induced rhabdomyolsis leading to acute compartment syndrome in the buttocks and sciatic nerve injury are rare. We have experience treating patients with acute compartment syndrome due to rhabdomyolysis following carbon monoxide poisoning. We report the characteristic features of muscle necrosis observed during a decompression operation and magnetic resonance imaging findings with a one-year follow-up in addition to a review of the literature.

  10. Measurements on high temperature fuel cells with carbon monoxide-containing fuel gases; Messungen an Hochtemperatur-Brennstoffzellen mit kohlenmonoxidhaltigen Brenngasen

    Energy Technology Data Exchange (ETDEWEB)

    Apfel, Holger

    2012-10-10

    In the present work the different power density of anode-supported high-temperature solid oxide fuel cells (ASC-SOFCs) were examined for carbon monoxide-containing fuels. In addition to wet hydrogen / carbon monoxide mixtures the cells were run with synthetic gas mixtures resembling the products of an autothermal reformer, and actual reformate generated by a 2 kW autothermal reformer. It was found that the power-voltage characteristics of an ASC depends primarily on the open circuit voltages of different gas mixtures, but is nearly independent of the hydrogen concentration of the fuel, although the reaction rates of other potential fuels within the gas mixture, namely carbon monoxide and methane, are much lower that the hydrogen reaction rate. The probable reason is that the main fuel for the electrochemical oxidation within the cell is hydrogen, while the nickel in the base layer of the anode acts as a reformer which replenishes the hydrogen by water reduction via carbon monoxide and methane oxidation.

  11. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    OpenAIRE

    Martijn eDiender; Alfons J.M. Stams; Alfons J.M. Stams; Diana Z. Sousa

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, ...

  12. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Directory of Open Access Journals (Sweden)

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  13. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    International Nuclear Information System (INIS)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  14. Carbon monoxide toxicity. April 1978-November 1989 (A Bibliography from the Life Sciences Collection data base). Report for April 1978-November 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (This updated bibliography contains 237 citations, 16 of which are new entries to the previous edition.)

  15. Influence of surface vacancy defects on the carburisation of Fe 110 surface by carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Chakrabarty, Aurab, E-mail: aurab.chakrabarty@qatar.tamu.edu; Bouhali, Othmane [Texas A& M University at Qatar, P.O. Box 23874, Doha (Qatar); Mousseau, Normand [Département de Physique and RQMP, Université de Montréal, Case Postale 6128, Succursale Centre-Ville, Montréal (QC) H3C 3J7 (Canada); Becquart, Charlotte S. [UMET, UMR CNRS 8207, ENSCL, Université Lille I, 59655 Villeneuve d’Ascq cédex (France); El-Mellouhi, Fedwa, E-mail: felmellouhi@qf.org.qa [Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University, P.O. Box 5825 Doha (Qatar)

    2016-07-28

    Adsorption and dissociation of gaseous carbon monoxide (CO) on metal surfaces is one of the most frequently occurring processes of carburisation, known as primary initiator of metal dusting corrosion. Among the various factors that can significantly influence the carburisation process are the intrinsic surface defects such as single surface vacancies occurring at high concentrations due to their low formation energy. Intuitively, adsorption and dissociation barriers of CO are expected to be lowered in the vicinity of a surface vacancy, due to the strong attractive interaction between the vacancy and the C atom. Here the adsorption energies and dissociation pathways of CO on clean and defective Fe 110 surface are explored by means of density functional theory. Interestingly, we find that the O adatom, resulting from the CO dissociation, is unstable in the electron-deficit neighbourhood of the vacancy due to its large electron affinity, and raises the barrier of the carburisation pathway. Still, a full comparative study between the clean surface and the vacancy-defected surface reveals that the complete process of carburisation, starting from adsorption to subsurface diffusion of C, is more favourable in the vicinity of a vacancy defect.

  16. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  17. 40 CFR Table 5 to Subpart Jjj of... - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units 5 Table 5 to Subpart JJJ of Part 62 Protection of... of Part 62—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units...

  18. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Directory of Open Access Journals (Sweden)

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  19. Systemic Administration of Carbon Monoxide-Releasing Molecule-3 Protects the Skeletal Muscle in Porcine Model of Compartment Syndrome.

    Science.gov (United States)

    Bihari, Aurelia; Cepinskas, Gediminas; Sanders, David; Lawendy, Abdel-Rahman

    2018-05-01

    Acute limb compartment syndrome, a complication of musculoskeletal trauma, results in muscle necrosis and cell death. Carbon monoxide, liberated from the carbon monoxide-releasing molecule-3, has been shown protective in a rat model of compartment syndrome. The purpose of this study was to test the effect of carbon monoxide-releasing molecule-3 in a preclinical large animal model of compartment syndrome, with the ultimate goal of developing a pharmacologic adjunct treatment for compartment syndrome. Animal research study. Basic research laboratory in a hospital setting. Male Yorkshire-Landrace pigs (50-60 kg). Pigs underwent 6 hours of intracompartmental pressure elevation by infusing fluid into the anterior compartment of the right hind limb. Carbon monoxide-releasing molecule-3 was administered systemically (2 mg/kg, IV) at fasciotomy, followed by 3-hour reperfusion. Muscle perfusion, inflammation, injury, and apoptosis were assessed in the skeletal muscle. Systemic leukocyte activation was assessed during compartment syndrome and reperfusion. Elevation of hind limb intracompartmental pressure resulted in significant microvascular perfusion deficits (44% ± 1% continuously perfused capillaries in compartment syndrome vs 76% ± 4% in sham; p molecule-3 at fasciotomy increased the number of continuously perfused capillaries (68% ± 3%; p molecule-3 at fasciotomy offered protection against compartment syndrome-induced microvascular perfusion deficit, tissue injury, and systemic leukocyte activation. The data suggest the potential therapeutic application of carbon monoxide-releasing molecule-3 to patients at risk of developing compartment syndrome.

  20. Range measurements of keV hydrogen ions in solid oxygen and carbon monoxide

    International Nuclear Information System (INIS)

    Schou, J.; Soerensen, H.; Andersen, H.H.; Nielsen, M.; Rune, J.

    1984-01-01

    Ranges of 1.3-3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen. The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees with that previously found for solid nitrogen. (orig.)

  1. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  2. Silicon Monoxide at 1 atm and Elevated Pressures: Crystalline or Amorphous?

    KAUST Repository

    AlKaabi, Khalid

    2014-03-05

    The absence of a crystalline SiO phase under ordinary conditions is an anomaly in the sequence of group 14 monoxides. We explore theoretically ordered ground-state and amorphous structures for SiO at P = 1 atm, and crystalline phases also at pressures up to 200 GPa. Several competitive ground-state P = 1 atm structures are found, perforce with Si-Si bonds, and possessing Si-O-Si bridges similar to those in silica (SiO2) polymorphs. The most stable of these static structures is enthalpically just a little more stable than a calculated random bond model of amorphous SiO. In that model we find no segregation into regions of amorphous Si and amorphous SiO2. The P = 1 atm structures are all semiconducting. As the pressure is increased, intriguing new crystalline structures evolve, incorporating Si triangular nets or strips and stishovite-like regions. A heat of formation of crystalline SiO is computed; it is found to be the most negative of all the group 14 monoxides. Yet, given the stability of SiO2, the disproportionation 2SiO (s) → Si(s)+SiO2(s) is exothermic, falling right into the series of group 14 monoxides, and ranging from a highly negative ΔH of disproportionation for CO to highly positive for PbO. There is no major change in the heat of disproportionation with pressure, i.e., no range of stability of SiO with respect to SiO2. The high-pressure SiO phases are metallic. © 2014 American Chemical Society.

  3. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    Directory of Open Access Journals (Sweden)

    Metin Uysalol

    2011-09-01

    Full Text Available Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide intoxication was heaters, waterheaters and fi re in 82.1%, 7.1% and 6% of cases, respectively. There was a statistically signifi cant difference between the carboxyhemoglobin levels of the patients according to the clinical classifi cation (p<0.05. The intoxication caused by heaters was observed signifi cantly in November, December and January (p<0.001, between 16:00-24:00 hours (p<0.001 and among more than one member of a family (p<0.001. A medium level correlation was detected between the treatment approach and clinical classifi cation (r=0.50, p<0.001. Conclusion: Carbon monoxide intoxication, in the presented series, was found to develop accidentally; mostly in the Winter season; during night hours when the family members gathered together. The carboxyhemoglobin levels were appropriate with the developing clinical findings. Carboxyhemoglobin level solely was not enough for achieving the diagnosis and planning the treatment.

  4. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  5. 40 CFR Table 2 to Subpart Aaaa of... - Carbon Monoxide Emission Limits for New Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for New... Pt. 60, Subpt. AAAA, Table 2 Table 2 to Subpart AAAA of Part 60—Carbon Monoxide Emission Limits for.... Compliance is determined by continuous emission monitoring systems. b Block averages, arithmetic mean. See...

  6. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  7. Titanium monoxide spectroscopy following laser-induced optical breakdown

    International Nuclear Information System (INIS)

    Parigger, Christian G.; Woods, Alexander C.; Keszler, Anna; Nemes, László; Hornkohl, James O.

    2012-01-01

    This work investigates Titanium Monoxide (TiO) in ablation-plasma by employing laser-induced breakdown spectroscopy (LIBS) with 1 to 10 TW/cm 2 irradiance, pulsed, 13 nanosecond, Q-switched Nd:YAG laser radiation at the fundamental wavelength of 1064 nm. The analysis of TiO is based on our first accurate determination of transition line strengths for selected TiO A-X, B-X, and E-X transitions, particularly TiO A-X γ and B-X γ′ bands. Electric dipole line strengths for the A 3 Φ-X 3 δ and B 3 Π-X 3 δ bands of TiO are computed. The molecular TiO spectra are observed subsequent to laser-induced breakdown (LIB). We discuss analysis of diatomic molecular spectra that may occur simultaneously with spectra originating from atomic species. Gated detection is applied to investigate the development in time of the emission spectra following LIB. Collected emission spectra allow one to infer micro-plasma parameters such as temperature and electron density. Insight into the state of the micro-plasma is gained by comparing measurements with predictions of atomic and molecular spectra. Nonlinear fitting of recorded and computed diatomic spectra provides the basis for molecular diagnostics, while atomic species may overlap and are simultaneously identified. Molecular diagnostic approaches similar to TiO have been performed for diatomic molecules such as AlO, C 2 , CN, CH, N 2 , NH, NO and OH.

  8. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  9. Fetal brain damage following maternal carbon monoxide intoxication: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Ginsberg, M D; Myers, R E

    1974-01-01

    Techniques of fetal monitoring, including fetal blood sampling in utero, were employed to study the physiological effects of acute maternal carbon monoxide intoxication on nine term-pregnant female rhesus monkeys exposed to 0.1 to 0.3% inspired carbon monoxide over 1 to 3 hr. The mothers tolerated carboxyhemoglobin levels exceeding 60% without clinical sequelae, whereas the fetuses promptly developed profound hypoxia upon exposure of the mothers to CO. The fetal COHb levels rose only gradually over 1 to 3 hr, and thus contributed only slightly to the development of early fetal hypoxia. The fetal hypoxia was associated with bradycardia, hypotension, and metabolic and respiratory acidosis. Severity of intrauterine hypoxia was closely correlated with the appearance of brain damage. Brain swelling associated with hemorrhagic necrosis of the cerebral hemispheres (severe brain damage) appeared only in fetuses whose arterial oxygen content was reduced below 1.0 ml/100 ml for at least 45 min during the maternal CO intoxication.

  10. Conversion of no-carrier-added [11C]carbon dioxide to [11C]carbon monoxide on molybdenum for the synthesis of 11C-labelled aromatic ketones

    International Nuclear Information System (INIS)

    Zeisler, S.K.; Nader, M.; Theobald, A.; Oberdorfer, F.

    1997-01-01

    A new method for the efficient conversion of no-carrier-added [ 11 C]carbon dioxide into [ 11 C]carbon monoxide is described. [ 11 C]Carbon dioxide produced by proton bombardment of ultra high purity nitrogen is pre-concentrated in a cryo trap and then passed through a quartz tube filled with a mesh of thin molybdenum wire heated to 850 o C. [ 11 C]Carbon dioxide readily reacts with molybdenum to form [ 11 C]carbon monoxide and molybdenum(IV) oxide. The latter also reduces carbon dioxide to carbon monoxide and helps improve the performance of the converter. [ 11 C]Carbon monoxide is purified from remaining [ 11 C]carbon dioxide and collected in a small silica trap from which it is eluted into a reaction mixture for the palladium-mediated synthesis of a 11 C-labelled aromatic ketone. Radiochemical yields of up to 81% (decay-corrected) for [ 11 C]carbon monoxide were obtained. Radiochemical purity and specific radioactivity of both [ 11 C]carbon monoxide and the 11 C-labelled ketone are sufficient for nuclear medical studies with PET. (Author)

  11. Iodine monoxide in the north subtropical free troposphere

    OpenAIRE

    O. Puentedura; M. Gil; A. Saiz-Lopez; T. Hay; M. Navarro-Comas; A. Gómez-Pelaez; E. Cuevas; J. Iglesias; L. Gomez

    2012-01-01

    Iodine monoxide (IO) differential slant column densities (DSCD) have been retrieved from a new multi-axis differential optical absorption spectroscopy (MAX-DOAS) instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and hence is representative of the free troposphere. We r...

  12. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  13. Electron beam interactions with CO on W[100] studied by Auger electron spectroscopy

    International Nuclear Information System (INIS)

    Housley, M.; King, D.A.

    1977-01-01

    The interaction of 2500 eV electrons with carbon monoxide chemisorbed on tungsten [100] was investigated by rapid-scan Auger electron spectroscopy. When no α state was present the O and C signals from the β state of CO were invariant during electron bombardment, giving an upper limit estimate for the electron stimulated desorption cross section, Qsub(β), of 2 x 10 -21 cm 2 . With the crystal at room temperature and saturated with CO, however, electron-beam induced accumulation of carbon was observed and characterised, the rate of the process being independent of CO pressure at pressures above 2 x 10 -8 Torr. At 450 K the rate was found to be pressure dependent up to at least 6 x 10 -7 Torr. A model is proposed for the accumulation process, which is based on electron beam dissociation of α 2 -CO to form adsorbed carbon and gaseous O and the creation of new sites for further α 2 -CO adsorption; it is in quantitative agreement with the results and yields a cross section for ESD of α 2 -CO (Qsub(α 2 )=1.55 X 10 -18 cm 2 ) in clo 2 e agreement with direct measurements. (Auth.)

  14. A Density Functional Theory Study of Doped Tin Monoxide as a Transparent p-type Semiconductor

    KAUST Repository

    Bianchi Granato, Danilo

    2012-05-01

    In the pursuit of enhancing the electronic properties of transparent p-type semiconductors, this work uses density functional theory to study the effects of doping tin monoxide with nitrogen, antimony, yttrium and lanthanum. An overview of the theoretical concepts and a detailed description of the methods employed are given, including a discussion about the correction scheme for charged defects proposed by Freysoldt and others [Freysoldt 2009]. Analysis of the formation energies of the defects points out that nitrogen substitutes an oxygen atom and does not provide charge carriers. On the other hand, antimony, yttrium, and lanthanum substitute a tin atom and donate n-type carriers. Study of the band structure and density of states indicates that yttrium and lanthanum improves the hole mobility. Present results are in good agreement with available experimental works and help to improve the understanding on how to engineer transparent p-type materials with higher hole mobilities.

  15. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  16. Carbon monoxide poisoning in Nigeria - it is time to pay attention ...

    African Journals Online (AJOL)

    Background: Carbon monoxide (CO) is a colourless, odourless gas and a cause of thousands of deaths across the world annually but its lethal consequences often go unrecognized, especially in developing countries. Aim: To discuss the subject of CO poisoning using local examples. Methods: Information was drawn from ...

  17. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    Science.gov (United States)

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  18. Library resources on the Internet

    Science.gov (United States)

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  19. A first principles study of the mechanical, electronic, and vibrational properties of lead oxide

    Science.gov (United States)

    Zhuravlev, Yu. N.; Korabel'nikov, D. V.

    2017-11-01

    The first principles study of the crystal structure, chemical bonds, elastic and mechanical properties, electron energy band structure and density, and normal long-wave vibrations of nine phases of lead monoxide, dioxide, and tetraoxide has been performed under normal and external pressure within the framework of density functional theory (DFT) with the Perdew-Becke-Ernzerhof (PBE) gradient exchange-correlation functional and its hybrid version with a 25-% Hartree-Fock (HF) exchange contribution in the basis of localized atom orbitals. The behavior of physical parameters has been studied using the cold four- and threeparameter equations of state. The parameters of the crystal structures are in satisfactory agreement with experimental data, and elastic constants indicate their mechanical stability and anisotropy in the elastic properties. The elasticity, shear, and Young moduli, hardness, acoustic velocities, and Debye temperature of dioxide on the one hand and monoxide and tetraoxide on the other hand appreciably differ from each other. The difference between electron properties may be explained by the character of hybridization in the upper filled and lower empty energy bands as evident from the density of states. In monoxide, the indirect band gap width decreases with increasing pressure at a rate of 0.16 eV/GPa, and the direct band gap width increases at a rate of 0.13 eV/GPa. To identify crystalline phases, the frequencies and intensities of long-wave modes active in IR and Raman spectra have been calculated.

  20. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  1. [Cerebellar Infarction After Carbon Monoxide Poisoning and Hyperbaric Oxygen Therapy].

    Science.gov (United States)

    Wick, Matthias; Schneiker, André; Bele, Sylvia; Pawlik, Michael; Meyringer, Helmut; Graf, Bernhard; Wendl, Christina; Kieninger, Martin

    2017-06-01

    We report on a patient who developed a space-occupying cerebellar infarction with occlusive hydrocephalus after a poisoning with carbon monoxide with the intention to commit suicide. A neurosurgical and intensive care therapy were needed. The patient's survival without severe neurological deficits could be secured due to the early detection of the intracerebral lesions. Georg Thieme Verlag KG Stuttgart · New York.

  2. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  3. Selection and Evaluation of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  4. 40 CFR Table 5 to Subpart Bbbb of... - Model Rule-Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Carbon Monoxide Emission... BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste... PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...

  5. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  6. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  7. Carbon monoxide is not responsible for the cigarette smokeinduced changes in the pulmonary metabolism of arachidonic acid and prostaglandin E2

    International Nuclear Information System (INIS)

    Maennistoe, J.; Puustinen, T.; Uotila, P.

    1985-01-01

    Cigarette smoke is known to interfere with the pulmonary metabolism of arachidomic acid and prostaglandin E 2 (PGE 2 ). We investigated the possible role of carbon monoxide in these cigarette smoke-infuced alterations. 4 C-Arachidonic acid (50 nmol) was indused into the pulmonary circulation of isolated perfused hamster lungs and the radioactive metabolites in the perfusion effluent, as well as the distribution of incorporated radioactive arachidonic acid within the lung lipids, were analysed. Carbon monoxide, added into the ventilatory air, had no effect on the oxidative metabolism of arachidonic acid or on the distribution of radioactive arachidonic acid within the lung. In addition, carbon monoxide had no effect on the metabolism of PGE 2 following infusion of 100 nmol of 14 C-PGE 2 into the rat pulmonary circulation. The present study suggests that carbon monoxide is not responsible for the cigarette smoke-induced changes in the pulmonary metabolism of arachidonic acid and PGE 2 . (author)

  8. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Directory of Open Access Journals (Sweden)

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  9. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Science.gov (United States)

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  10. The Future of Carbon Monoxide Measurements from Space

    Science.gov (United States)

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  11. Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.

    Science.gov (United States)

    Towers, Craig V; Corcoran, Vincent A

    2009-03-01

    The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.

  12. Effects of acetylene and carbon monoxide on long-term hydrogen production by Mastigocladus laminosus, a thermophilic blue-green alga

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Yokoyama, H; Takahara, K; Miyamoto, K

    1982-01-01

    Long-term H/sub 2/ production by a thermophilic and heterocystous blue-green alga (cyanobacterium) Mastigocladus laminosus was studied under the conditions when acetylene and carbon monoxide were supplemented to the gas phase of the culture vessel. The addition of both gases enhanced H/sub 2/ evolution by nitrogen-starved cells. The concentrations of acetylene and carbon monoxide in the gas phase of argon/CO/sub 2/ (97.5/2.5) were 10% and 0.2 to 1%, respectively, for the maximum H/sub 2/ production. Renewals of the gas phase, in addition to the addition of acetylene and carbon monoxide, were necessary for durable H/sub 2/ production. Since the concentrations of both H/sub 2/ and O/sub 2/ accumulated in the gas phase were minimized after the renewals, the H/sub 2/ uptake activity, which was not completely inhibited by acetylene and carbon monoxide, was reduced and thereby H/sub 2/ evolution was restored. Under such conditions, H/sub 2/ production for up to 20 days was observed under argon and N/sub 2/ atmospheres with average rats of 3.9 and 3.3..mu..l/mg dry wt/h, respectively. H/sub 2/ evolution for 15 days was observed even under an air atmosphere containing acetylene and carbon monoxide. It was thus shown that prolonged production of H/sub 2/ was possible by the use of a blue-green alga which exhibits a high activity of H/sub 2/ uptake under nitrogen-starved conditions.

  13. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  14. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  15. MODELLING OF CARBON MONOXIDE AIR POLLUTION IN LARG CITIES BY EVALUETION OF SPECTRAL LANDSAT8 IMAGES

    Directory of Open Access Journals (Sweden)

    M. Hamzelo

    2015-12-01

    Full Text Available Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS , spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  16. Geostatistical modelling of carbon monoxide levels in Khartoum State (Sudan) - GIS pilot based study

    Energy Technology Data Exchange (ETDEWEB)

    Alhuseen, A [Comenius University in Bratislava, Faculty of Natural Sciences, Dept. of Landscape Ecology, 84215 Bratislava (Slovakia); Madani, M [Ministry of Environment and Physical Development, 1111 Khartoum (Sudan)

    2012-04-25

    The objective of this study is to develop a digital GIS model; that can evaluate, predict and visualize carbon monoxide (CO) levels in Khartoum state. To achieve this aim, sample data had been collected, processed and managed to generate a dynamic GIS model of carbon monoxide levels in the study area. Parametric data collected from the field and analysis carried throughout this study show that (CO) emissions were lower than the allowable ambient air quality standards released by National Environment Protection Council (NEPC-USA) for 1998. However, this pilot study has found emissions of (CO) in Omdurman city were the highest. This pilot study shows that GIS and geostatistical modeling can be used as a powerful tool to produce maps of exposure. (authors)

  17. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad; Farooq, Aamir

    2018-01-01

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm

  18. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    Science.gov (United States)

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  19. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    Science.gov (United States)

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  20. Health effects of carbon monoxide environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    Carbon monoxide's (CO) chronic effects on man, its sources, and measuring methods are reviewed, and guidelines to determine health criteria are considered. The European data exchange included CO measuring methods in air and blood and their use in survey and experimental work, atmospheric CO pollution and sampling methods in urban thoroughfares and road tunnels in the European countries, a population survey of carboxyhemoglobin levels from cigarette smoking and atmospheric exposure, and physiological kinetics (uptake, distribution, and elimination) of CO inhalation. Additional topics are CO and the central nervous system, effects of moderate CO exposure on the cardiovascular system and on fetal development, and the current views on existing air quality criteria for CO.

  1. Multimodel simulations of carbon monoxide: comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Krol, M.C.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-ofthe- art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  2. Using mobile electronic devices to deliver educational resources in developing countries.

    Science.gov (United States)

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  3. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Analysis of patients presenting to the emergency department with carbon monoxide intoxication

    Directory of Open Access Journals (Sweden)

    Selim Yurtseven

    2015-12-01

    Full Text Available Objectives: Carbon monoxide is a potentially fatal form of poisoning. The exact incidence is unclear, due to cases being undiagnosed or reported as fewer than the real number. Hyperbaric oxygen therapy (HBOT is of proven efficacy in the treatment of CO intoxication.The purpose of this study was to describe the general characteristics of carbon monoxide (CO intoxications presenting to the emergency department and to investigate troponin I values and the effectiveness of hyperbaric oxygen therapy (HBOT in these patients. Material and methods: Patients presenting to the emergency department with CO intoxication over one year and patients with such intoxications receiving HBOT were examined retrospectively. Results: One hundred seventy-one patients were included; 140 (81.9% were poisoned by stoves, 18 (10.5% by hot water boilers and 10 in (5.8% by fires. COHb levels were normal in 49 of the 163 patients whose values were investigated, and were elevated in 114 patients. Mean COHb value was 16.6. Troponin I values were investigated in 112 patients. These were normal in 86 patients and elevated in 26. Mean troponin I value was 0.38 ng/ml. One hundred twenty-three of the 171 patients in the study were discharged in a healthy condition after receiving normobaric oxygen therapy, while 48 patients received HBOT. Forty-two (87.5% of the patients receiving HBOT were discharged in a healthy condition while sequelae persisted in five (10.4%. One patient died after 15 session of HBOT. Conclusion: Although elevated carboxyhemoglobin confirms diagnosis of CO intoxication, normal levels do not exclude it. Troponin I levels may rise in CO intoxication. No significant relation was observed between carboxyhemoglobin and receipt of HBOT. A significant correlation was seen, however, between troponin I levels and receipt of HBOT. Keywords: Carbon monoxide intoxication, Hyperbaric oxygen, Troponin I, Echocardiography

  5. Multimodel simulations of carbon monoxide: Comparison with observations and projected near-future changes

    NARCIS (Netherlands)

    Shindell, D.T.; Faluvegi, G.; Stevenson, D.S.; Krol, M.C.; Emmons, L.K.; Lamarque, J.F.; Petron, G.; Dentener, F.J.; Ellingsen, K.; Schultz, M.G.; Wild, O.; Amann, M.; Atherton, C.S.; Bergmann, D.J.; Bey, I.; Butler, T.; Cofala, J.; Collins, W.J.; Derwent, R.G.; Doherty, R.M.; Drevet, J.; Eskes, H.J.; Fiore, A.M.; Gauss, M.; Hauglustaine, D.A.; Horowitz, L.W.; Isaksen, I.S.A.; Lawrence, M.G.; Montanaro, V.; Muller, J.F.; Pitari, G.; Prather, M.J.; Pyle, J.A.; Rast, S.; Rodriguez, J.M.; Sanderson, M.G.; Savage, N.H.; Strahan, S.E.; Sudo, K.; Szopa, S.; Unger, N.; Noije, van T.P.C.; Zeng, G.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-of-the-art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  6. CO2 Reduction Catalyzed by Nitrogenase: Pathways to Formate, Carbon Monoxide, and Methane.

    Science.gov (United States)

    Khadka, Nimesh; Dean, Dennis R; Smith, Dayle; Hoffman, Brian M; Raugei, Simone; Seefeldt, Lance C

    2016-09-06

    The reduction of N2 to NH3 by Mo-dependent nitrogenase at its active-site metal cluster FeMo-cofactor utilizes reductive elimination of Fe-bound hydrides with obligatory loss of H2 to activate the enzyme for binding/reduction of N2. Earlier work showed that wild-type nitrogenase and a nitrogenase with amino acid substitutions in the MoFe protein near FeMo-cofactor can catalytically reduce CO2 by two or eight electrons/protons to carbon monoxide (CO) and methane (CH4) at low rates. Here, it is demonstrated that nitrogenase preferentially reduces CO2 by two electrons/protons to formate (HCOO(-)) at rates >10 times higher than rates of CO2 reduction to CO and CH4. Quantum mechanical calculations on the doubly reduced FeMo-cofactor with a Fe-bound hydride and S-bound proton (E2(2H) state) favor a direct reaction of CO2 with the hydride ("direct hydride transfer" reaction pathway), with facile hydride transfer to CO2 yielding formate. In contrast, a significant barrier is observed for reaction of Fe-bound CO2 with the hydride ("associative" reaction pathway), which leads to CO and CH4. Remarkably, in the direct hydride transfer pathway, the Fe-H behaves as a hydridic hydrogen, whereas in the associative pathway it acts as a protic hydrogen. MoFe proteins with amino acid substitutions near FeMo-cofactor (α-70(Val→Ala), α-195(His→Gln)) are found to significantly alter the distribution of products between formate and CO/CH4.

  7. Imaging quasiperiodic electronic states in a synthetic Penrose tiling

    Science.gov (United States)

    Collins, Laura C.; Witte, Thomas G.; Silverman, Rochelle; Green, David B.; Gomes, Kenjiro K.

    2017-06-01

    Quasicrystals possess long-range order but lack the translational symmetry of crystalline solids. In solid state physics, periodicity is one of the fundamental properties that prescribes the electronic band structure in crystals. In the absence of periodicity and the presence of quasicrystalline order, the ways that electronic states change remain a mystery. Scanning tunnelling microscopy and atomic manipulation can be used to assemble a two-dimensional quasicrystalline structure mapped upon the Penrose tiling. Here, carbon monoxide molecules are arranged on the surface of Cu(111) one at a time to form the potential landscape that mimics the ionic potential of atoms in natural materials by constraining the electrons in the two-dimensional surface state of Cu(111). The real-space images reveal the presence of the quasiperiodic order in the electronic wave functions and the Fourier analysis of our results links the energy of the resonant states to the local vertex structure of the quasicrystal.

  8. Toxicological Investigation of Acute Carbon Monoxide Poisoning in Four Occupants of a Fuming Sport Utility Vehicle

    Directory of Open Access Journals (Sweden)

    Martin Nnoli

    2014-11-01

    Full Text Available Background: This toxicological investigation involves a report on the death of four occupants of a sport utility vehicle on one of the major busy Federal roads of Nigeria where they were held for up to three hours in a traffic jam while the car was steaming. Methods: Autopsy was executed using the standard procedure and toxicological analysis was done using simple spectrophotometric method to establish the level of carboxyhaemoglobin (HbCO in peripheral blood in the four occupants. Results: The autopsy report indicated generalized cyanosis, sub-conjuctival hemorrhages, marked laryngo-trachea edema with severe hyperemia with frothy fluid discharges characteristic of carbon monoxide poisoning. Toxicological report of the level of HbCO in part per million (ppm in the peripheral blood of the four occupants was A= 650 ppm; B= 500 ppm; C= 480 ppm, and D= 495 ppm against the maximum permissible level of 50 ppm. Conclusion: The sudden death of the four occupants was due to excessive inhalation of the carbon monoxide gas from the exhaust fumes leaking into the cabin of the car. The poor road network, numerous potholes, and traffic jam in most of roads in Nigeria could have exacerbated a leaky exhaust of the smoky second hand SUV car leading to the acute carbon monoxide poisoning.

  9. Carbon monoxide and respiratory symptoms in young adult passive smokers: A pilot study comparing waterpipe to cigarette

    Directory of Open Access Journals (Sweden)

    Rouba Zeidan

    2014-08-01

    Full Text Available Objectives: Studies have correlated second hand smoke (SHS with many diseases, especially respiratory effects. The goal of this study was to measure the impact of SHS on the respiratory symptoms and exhaled carbon monoxide. Material and Methods: The study population consisted of 50 young workers in restaurants serving waterpipes, 48 university students who sit frequently in the university cafeteria where cigarette smoking is allowed and 49 university students spending time in places where smoking is not allowed. Subjects completed questionnaires on socio-demographic characteristics, respiratory symptoms and exposure to SHS. Exhaled carbon monoxide levels were measured. ANOVA and Chi-square tests were used when applicable as well as linear and logistic regression analysis. Results: Exposure to cigarette smoke in university (adjusted odds ratio (ORa = 6.06 and occupational exposure to waterpipe smoke (ORa = 7.08 were predictors of chronic cough. Being married (ORa = 6.40, living near a heavy traffic road (ORa = 9.49 or near a local power generator (ORa = 7.54 appeared responsible for chronic sputum production. Moreover, predictors of chronic allergies were: being male (ORa = 7.81, living near a local power generator (ORa = 5.52 and having a family history of chronic respiratory diseases (ORa = 17.01. Carbon monoxide levels were augmented by the number of weekly hours of occupational exposure to waterpipe smoke (β = 1.46 and the number of daily hours of exposure to cigarette smoke (β = 1.14. Conclusions: In summary, young non-smoker subjects demonstrated more chronic cough and elevated carbon monoxide levels when exposed to SHS while the effect of waterpipe was even more evident.

  10. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Directory of Open Access Journals (Sweden)

    Martijn eDiender

    2015-11-01

    Full Text Available Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  11. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    Science.gov (United States)

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  12. Selected constituents in the smokes of U. S. commercial cigaretts: tar, nicotine, carbon monoxide and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    One hundred twenty-one brands of United States commercial cigarettes were analyzed for their deliveries of tar, nicotine, carbon monoxide, and carbon dioxide under standard analytical smoking conditions. The sample included both filter and nonfilter cigarettes. Comparisons of carbon monoxide deliveries over the range of observed tar deliveries indicated a very high correlation between CO and tar for filter cigarettes, but nonfilter cigarettes tended to produce much less CO than would have been predicted from their tar deliveries. Comparison of ORNL nicotine values for specific brands with those determined by the Federal Trade Commission yield no statistically significant differences between laboratories. 4 figures, 6 tables.

  13. A Novel Gas Sensor Based on MgSb2O6 Nanorods to Indicate Variations in Carbon Monoxide and Propane Concentrations

    Science.gov (United States)

    Guillén-Bonilla, Héctor; Flores-Martínez, Martín; Rodríguez-Betancourtt, Verónica-María; Guillen-Bonilla, Alex; Reyes-Gómez, Juan; Gildo-Ortiz, Lorenzo; de la Luz Olvera Amador, María; Santoyo-Salazar, Jaime

    2016-01-01

    Bystromite (MgSb2O6) nanorods were prepared using a colloidal method in the presence of ethylenediamine, after a calcination step at 800 °C in static air. From X-ray powder diffraction analyses, a trirutile-type structure with lattice parameters a = 4.64 Å and c = 9.25 Å and space group P42/mnm was identified. Using scanning electron microscopy (SEM), microrods with sizes from 0.2 to 1.6 μm were observed. Transmission electron microscopy (TEM) analyses revealed that the nanorods had a length of ~86 nm and a diameter ~23.8 nm. The gas-sensing properties of these nanostructures were tested using pellets elaborated with powders of the MgSb2O6 oxide (calcined at 800 °C) at temperatures 23, 150, 200, 250 and 300 °C. The pellets were exposed to different concentrations of carbon monoxide (CO) and propane (C3H8) at these temperatures. The results showed that the MgSb2O6 nanorods possess excellent stability and high sensitivity in these atmospheres. PMID:26840318

  14. A Novel Gas Sensor Based on MgSb2O6 Nanorods to Indicate Variations in Carbon Monoxide and Propane Concentrations

    Directory of Open Access Journals (Sweden)

    Héctor Guillén-Bonilla

    2016-01-01

    Full Text Available Bystromite (MgSb2O6 nanorods were prepared using a colloidal method in the presence of ethylenediamine, after a calcination step at 800 °C in static air. From X-ray powder diffraction analyses, a trirutile-type structure with lattice parameters a = 4.64 Å and c = 9.25 Å and space group P42/mnm was identified. Using scanning electron microscopy (SEM, microrods with sizes from 0.2 to 1.6 μm were observed. Transmission electron microscopy (TEM analyses revealed that the nanorods had a length of ~86 nm and a diameter ~23.8 nm. The gas-sensing properties of these nanostructures were tested using pellets elaborated with powders of the MgSb2O6 oxide (calcined at 800 °C at temperatures 23, 150, 200, 250 and 300 °C. The pellets were exposed to different concentrations of carbon monoxide (CO and propane (C3H8 at these temperatures. The results showed that the MgSb2O6 nanorods possess excellent stability and high sensitivity in these atmospheres.

  15. High Resolution Spectra of Carbon Monoxide, Propane and Ammonia for Atmospheric Remote Sensing

    Science.gov (United States)

    Beale, Christopher Andrew

    Spectroscopy is a critical tool for analyzing atmospheric data. Identification of atmospheric parameters such as temperature, pressure and the existence and concentrations of constituent gases via remote sensing techniques are only possible with spectroscopic data. These form the basis of model atmospheres which may be compared to observations to determine such parameters. To this end, this dissertation explores the spectroscopy of three molecules: ammonia, propane and carbon monoxide. Infrared spectra have been recorded for ammonia in the region 2400-9000 cm-1. These spectra were recorded at elevated temperatures (from 293-973 K) using a Fourier Transform Spectrometer (FTS). Comparison between the spectra recorded at different temperatures yielded experimental lower state energies. These spectra resulted in the measurement of roughly 30000 lines and about 3000 quantum assignments. In addition spectra of propane were recorded at elevated temperatures (296-700 K) using an FTS. Atmospheres with high temperatures require molecular data at appropriate conditions. This dissertation describes collection of such data and the potential application to atmospheres in our solar system, such as auroral regions in Jupiter, to those of planets orbiting around other stars and cool sub-stellar objects known as brown dwarfs. The spectra of propane and ammonia provide the highest resolution and most complete experimental study of these gases in their respective spectral regions at elevated temperatures. Detection of ammonia in an exoplanet or detection of propane in the atmosphere of Jupiter will most likely rely on the work presented here. The best laboratory that we have to study atmospheres is our own planet. The same techniques that are applied to these alien atmospheres originated on Earth. As such it is appropriate to discuss remote sensing of our own atmosphere. This idea is explored through analysis of spectroscopic data recorded by an FTS on the Atmospheric Chemistry

  16. Forensic aspects of carbon monoxide poisoning by charcoal burning in Denmark, 2008-2012

    DEFF Research Database (Denmark)

    Nielsen, Pia Rude; Gheorghe, Alexandra; Lynnerup, Niels

    2014-01-01

    Carbon monoxide (CO) inhalation is a well-known method of committing suicide. There has been a drastic increase in suicide by inhalation of CO, produced from burning charcoal, in some parts of Asia, and a few studies have reported an increased number of these deaths in Europe. CO-related deaths c...

  17. A Rare Cause of Chronic Headache that May Be Misdiagnosed as Migraine: Chronic Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet Kenan KANBUROGLU

    2014-09-01

    Full Text Available SUMMARY: Differential diagnosis of primary headache disorders can be challenging for physicians. Although the association of headache with acute carbon monoxide intoxication is very well-defined, in refractory nonspecific headaches associated with chronic low dose exposure to carbon monoxide, CO intoxication is usually overlooked, mostly due to vague symptoms. Herein we present a 15-year-old female patient with chronic carbon monoxide poisoning who was undergoing two years of follow-up care for migraines. Chronic carbon monoxide intoxication may mimic the episodic nature and familial predisposition of migraine attacks. Normal carboxyhemoglobin levels do not exclude the diagnosis, and smoking is a confounding factor. In emergency rooms, patients presenting with headaches had higher levels of carboxyhemoglobin, but, as far as we know, there have been no studies investigating carboxyhemoglobin levels in migraine patients. Chronic carbon monoxide poisoning should be suspected in migraine patients, especially if the attacks occur during winter months. ÖZET: Primer baş ağrısında ayırıcı tanının yapılması bazen doktorlar açısından zor olabilmektedir. Literatürde karbon monoksit ile baş ağrısı arasındaki ilişki çok iyi ortaya konulmuş olmasına karşın, dirençli ve nonspesifik başağrısı nedenlerinden biri olan kronik düşük doz karbon monoksit maruziyeti kendine özgü bulgusu olmadığından sıklıkla atlanmaktadır. Bu yazıda, iki yıl migren tanısı ile takip ve tedavi edilen kronik karbon monoksit zehirlenmesi olan bir olgu sunuldu. Kronik karbon monoksit zehirlenmesi epizodik paterni ve aile fertlerinde benzer şikayetlerin olması nedeniyle migren ataklarını andırabilmektedir. Karboksihemoglobin konsantrasyonlarının normal saptanması tanıyı ekarte ettirmemekte, ayrıca sigara kullanımı da karıştırıcı bir faktör olabilmektedir. Acil servislerine baş ağrısı ile başvuran hastalar

  18. Gas-phase studies of AunOm+ interacting with carbon monoxide

    Science.gov (United States)

    Kimble, M. L.; Castleman, A. W.

    2004-04-01

    The results of reactions between preformed cationic gold oxide clusters and carbon monoxide have been investigated utilizing a fast-flow reactor mass spectrometer. From these studies, it was found that all AunOm+ produced in the cluster source disappeared with CO addition at the reactant gas inlet. Furthermore, with CO addition, intermediate peaks of the form AunOm(CO)x+ (n=1-2, m=0-3, x=0-2) were produced, with some of the species continuing to react at higher CO flows.

  19. Characterization of Carbon Monoxide Exposure During Hurricane Sandy and Subsequent Nor'easter.

    Science.gov (United States)

    Schnall, Amy; Law, Royal; Heinzerling, Amy; Sircar, Kanta; Damon, Scott; Yip, Fuyuen; Schier, Josh; Bayleyegn, Tesfaye; Wolkin, Amy

    2017-10-01

    Carbon monoxide (CO) is an odorless, colorless gas produced by fossil fuel combustion. On October 29, 2012, Hurricane Sandy moved ashore near Atlantic City, New Jersey, causing widespread morbidity and mortality, $30 to $50 billion in economic damage, and 8.5 million households to be without power. The combination of power outages and unusually low temperatures led people to use alternate power sources, placing many at risk for CO exposure. We examined Hurricane Sandy-related CO exposures from multiple perspectives to help identify risk factors and develop strategies to prevent future exposures. This report combined data from 3 separate sources (health departments, poison centers via the National Poison Data System, and state and local public information officers). Results indicated that the number of CO exposures in the wake of Hurricane Sandy was significantly greater than in previous years. The persons affected were mostly females and those in younger age categories and, despite messaging, most CO exposures occurred from improper generator use. Our findings emphasize the continued importance of CO-related communication and ongoing surveillance of CO exposures to support public health response and prevention during and after disasters. Additionally, regional poison centers can be a critical resource for potential on-site management, public health promotion, and disaster-related CO exposure surveillance. (Disaster Med Public Health Preparedness. 2017;11:562-567).

  20. Study of photoionization and dissociative photoionization of carbon monoxide from ionization threshold to 38 eV by using synchrotron radiation

    International Nuclear Information System (INIS)

    Zhao, Yujie; Cao, Maoqi; Li, Yuquan; Shan, Xiaobin; Liu, Fuyi; Sheng, Liusi; Li, Li; Liu, Wanfang

    2014-01-01

    Highlights: • The high resolution photoionization spectrum of carbon monoxide has been investigated using tunable synchrotron radiation. • This work has investigated comprehensively almost all kinds of photo excitation processes of CO in wide photon region. • The mechanisms of photoionization and dissociative photoionization of CO have been researched in detail. - Abstract: The vacuum-ultraviolet photoionization and dissociative photoionization of carbon monoxide in a region 14–38 eV have been investigated with time-of-flight (TOF) photoionization mass spectrometry (PIMS) using tunable synchrotron radiation (SR). The adiabatic ionization energy (IE) of carbon monoxide and appearance energies (AE) for its fragment ions in different states are determined by measurements of photoionization efficiency spectra (PIES). Ab initio calculations have been performed to investigate the reaction mechanism of dissociative photoionization of carbon monoxide. On the basis of experimental and predicted theoretical results, the mechanisms of photoionization and dissociative photoionization of molecular CO are discussed, and sixteen dissociative photoionization processes are proposed. The equilibrium geometries and harmonic vibrational frequencies of CO molecule, and its parent cation were calculated by using MP2 (full) method. The differences of configurations between them are also discussed on the basis of theoretical calculations. According to our results, the experimental IE of CO molecule, and dissociation energies (E d ) of possible dissociative channels are in reasonable agreement with the calculated values of the proposed photodissociation channels

  1. Ratio of carbon monoxide to molecular hydrogen in interstellar dark clouds

    International Nuclear Information System (INIS)

    Dickman, R.L.; Rensselaer Polytechnic Institute; and The Ivan A. Getting Laboratories, The Aerospace Corporation)

    1978-01-01

    Carbon monoxide and molecular hydrogen column densities are compared at various locations within 38 interstellar dark clouds. CO column densities were obtained from radio observations of the J=1→0 transitions of the 12 C 16 O and 13 C 16 O isotopic species of the molecule. Corresponding H 2 column densities were inferred by means of visual extinctions derived from star counts, since it is argued that the standard gas-to-extinction ratio can be expected to remain valid in the clouds studied. For locations in the sources possessing line-of-sight visual extinctions in the approximate range 1.5 -2 ) = (5.0 +- 2.5) x 10 5 N 13 between molecular hydrogen and 13 CO LTE column densities. The carbon monoxide molecule can therefore be used as a quantitative ''tracer'' for the (directly unobservable) H 2 content of dark clouds. The above relationship implies that at least approx.12% of the gas-phase carbon in the clouds studied is in the form of CO, provided that the clouds are assumed to be chemically homogeneous. Langer's ion-molecule chemistry for dark clouds appears to agree well with the present work if the fractionation channel of Watson, Anicich, and Huntress is included

  2. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Directory of Open Access Journals (Sweden)

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  3. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  4. Non-intentional motor vehicle-related carbon monoxide deaths-revisited

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, A.R.

    1986-01-01

    A study of non-intentional, motor vehicle-related, carbon monoxide-related deaths was performed on the case files of the Office of the Medical Examiner of Metropolitan Dade Country in Miami, FL (USA) during the years 1980-1984. A total of 15 cases were collected during that time period. These are presented in some detail. A discussion ensues that compares the similar circumstances of these cases, notably running the engine of an automobile in an enclosed space, with older reports in the literature which emphasized defective vehicle exhaust systems as the leading etiology for these deaths.

  5. Iodine monoxide in the north subtropical free troposphere [Discussion paper

    OpenAIRE

    Puentedura, Olga; Gil-Ojeda, Manuel; Saiz-Lopez, Alfonso; Hay, Tim; Navarro Comas, Mónica; Gómez Peláez, Ángel Jesús; Cuevas Agulló, Emilio; Iglesias, J.

    2011-01-01

    Iodine monoxide (IO) was retrieved using a new multi-axis DOAS instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and is hence representative of the free troposphere. We report daily observations from May to August 2010 at different viewing angles. During this period, t...

  6. Status epilepticus and cardiopulmonary arrest in a patient with carbon monoxide poisoning with full recovery after using a neuroprotective strategy: a case report

    Directory of Open Access Journals (Sweden)

    Abdulaziz Salman

    2012-12-01

    Full Text Available Abstract Introduction Carbon monoxide poisoning can be associated with life-threatening complications, including significant and disabling cardiovascular and neurological sequelae. Case presentation We report a case of carbon monoxide poisoning in a 25-year-old Saudi woman who presented to our facility with status epilepticus and cardiopulmonary arrest. Her carboxyhemoglobin level was 21.4 percent. She made a full recovery after we utilized a neuroprotective strategy and normobaric oxygen therapy, with no delayed neurological sequelae. Conclusions Brain protective modalities are very important for the treatment of complicated cases of carbon monoxide poisoning when they present with neurological toxicities or cardiac arrest. They can be adjunctive to normobaric oxygen therapy when the use of hyperbaric oxygen is not feasible.

  7. Serum bilirubin value predicts hospital admission in carbon monoxide-poisoned patients. Active player or simple bystander?

    Directory of Open Access Journals (Sweden)

    Gianfranco Cervellin

    Full Text Available OBJECTIVES: Although carbon monoxide poisoning is a major medical emergency, the armamentarium of recognized prognostic biomarkers displays unsatisfactory diagnostic performance for predicting cumulative endpoints. METHODS: We performed a retrospective and observational study to identify all patients admitted for carbon monoxide poisoning during a 2-year period. Complete demographical and clinical information, along with the laboratory data regarding arterial carboxyhemoglobin, hemoglobin, blood lactate and total serum bilirubin, was retrieved. RESULTS: The study population consisted of 38 poisoned patients (23 females and 15 males; mean age 39±21 years. Compared with discharged subjects, hospitalized patients displayed significantly higher values for blood lactate and total serum bilirubin, whereas arterial carboxyhemoglobin and hemoglobin did not differ. In a univariate analysis, hospitalization was significantly associated with blood lactate and total serum bilirubin, but not with age, sex, hemoglobin or carboxyhemoglobin. The diagnostic performance obtained after combining the blood lactate and total serum bilirubin results (area under the curve, 0.90; 95% CI, 0.81-0.99; p<0.001 was better than that obtained for either parameter alone. CONCLUSION: Although it remains unclear whether total serum bilirubin acts as an active player or a bystander, we conclude that the systematic assessment of bilirubin may, alongside lactate levels, provide useful information for clinical decision making regarding carbon monoxide poisoning.

  8. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  9. Recent changes in atmospheric carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Masarie, K.A. (Univ. of Colorado, Boulder, CO (United States)); Tans, P.P.; Lang, P.M. (National Oceanic and Atmospheric Administration, Boulder, CO (United States))

    1994-03-18

    Measurements of carbon monoxide (CO) in air samples collected from 27 locations between 71[degrees]N and 41[degrees]S show that atmospheric levels of this gas have decreased worldwide over the past 2 to 5 years. During this period, CO decreased at nearly a constant rate in the high northern latitudes. In contrast, in the tropics an abrupt decrease occurred beginning at the end of 1991. In the Northern Hemisphere, CO decreased at a spatially and temporally averaged rate of 7.3 ([+-]0.9) parts per billion per year (6.1 percent per year) from June 1990 to June 1993, whereas in the Southern Hemisphere, CO decreased 4.2 ([+-]0.5) parts per billion per year (7.0 percent per year). This recent change is opposite a long-term trend of a 1 to 2 percent per year increase inferred from measurements made in the Northern Hemisphere during the past 30 years.

  10. Vibrationally Excited Carbon Monoxide Produced via a Chemical Reaction Between Carbon Vapor and Oxygen

    Science.gov (United States)

    Jans, Elijah R.; Eckert, Zakari; Frederickson, Kraig; Rich, Bill; Adamovich, Igor V.

    2017-06-01

    Measurements of the vibrational distribution function of carbon monoxide produced via a reaction between carbon vapor and molecular oxygen has shown a total population inversion on vibrational levels 4-7. Carbon vapor, produced using an arc discharge to sublimate graphite, is mixed with an argon oxygen flow. The excited carbon monoxide is vibrationally populated up to level v=14, at low temperatures, T=400-450 K, in a collision-dominated environment, 15-20 Torr, with total population inversions between v=4-7. The average vibrational energy per CO molecule formed by the reaction is 0.6-1.2 eV/molecule, which corresponds to 10-20% of the reaction enthalpy. Kinetic modeling of the flow reactor, including state specific vibrational processes, was performed to infer the vibrational distribution of the products of the reaction. The results show viability of developing of a new chemical CO laser from the reaction of carbon vapor and oxygen.

  11. Computed tomography of delayed encephalopathy of acute carbon monoxide poisoning - correlation with clinical findings -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Chung, Sung Hoon; Choo, In Wook; Chang, Kee Hyun

    1986-01-01

    Cerebral computed tomography (CT) findings were described in twenty-six cases with the late sequelae of acute carbon monoxide poisoning and were computed with the neurological symptoms and signs. The CT findings include symmetrical periventricular white matter low density in five cases, globes pallidus low density in six cases, ventricular dilatation in seven cases, ventricular dilatation and sulci widening in three cases, and normal findings in ten cases. Only one case showed low densities in both periventricular white matter and globes pallidus. Late sequelae of the interval from of carbon monoxide poisoning were clinically categorized as cortical dysfunction, parkinsonian feature, and cerebella dysfunction. The severity of the clinical symptoms and signs of neurological sequelae is generally correlated with presence and multiplicity of abnormal brain CT findings. But of fourteen cases showing the parkinsonian feature, only five cases had low density of globes pallidus in brain CT. Another case showing small unilateral low density of globes pallidus had no parkinsonian feature but showed mild cortical dysfunction.

  12. The chest X-ray in pulmonary capillary haemorrhage: correlation with carbon monoxide uptake

    International Nuclear Information System (INIS)

    Bowley, N.B.; Hughes, J.M.B.; Steiner, R.E.

    1979-01-01

    Serial changes in carbon monoxide uptake (Ksub(CO) or Dsub(L)CO/VA) were used to monitor episodes of pulmonary capillary haemorrhage in Goodpasture's syndrome (13 cases), immune complex nephritis (three cases) and idiopathic haemosiderosis (one case). Air-space shadowing on the chest X-ray (on a scoring system 0 to 12) was assessed in the light of the changes of Ksub(CO). In 14 out of 27 episodes of bleeding, the rise and fall of Ksub(CO) was matched in time by the appearance and disappearance of air-space shadowing on the chest X-ray. In six episodes the chest X-ray remained normal despite a rise of Ksub(CO). In two cases air-space shadowing appeared up to 48 h after the rise of Ksub(CO). On five occasions chest X-ray abnormalities preceded the rise of Ksub(CO) but chest infection or fluid overload accounted for three of these. In cases with suspected pulmonary capillary haemorrhage, measurements of carbon monoxide uptake will provide additional information and will assist in the interpretation of the chest X-ray. (author)

  13. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  14. Density functional theory study of interactions between carbon monoxide and iron tetraaza macrocyclic complexes, FeTXTAA (X = -Cl, -OH, -OCH3, -NH2, and -NO2).

    Science.gov (United States)

    de Matos Mourão Neto, Isaias; Silva, Adilson Luís Pereira; Tanaka, Auro Atsushi; de Jesus Gomes Varela, Jaldyr

    2017-02-01

    This work describes a DFT level theoretical quantum study using the B3LYP functional with the Lanl2TZ(f)/6-31G* basis set to calculate parameters including the bond distances and angles, electronic configurations, interaction energies, and vibrational frequencies of FeTClTAA (iron-tetrachloro-tetraaza[14]annulene), FeTOHTAA (iron-tetrahydroxy-tetraaza[14]annulene), FeTOCH 3 TAA (iron- tetramethoxy-tetraaza[14]annulene), FeTNH 2 TAA (iron-tetraamino-tetraaza[14]annulene), and FeTNO 2 TAA (iron-tetranitro-tetraaza[14]annulene) complexes, as well as their different spin multiplicities. The calculations showed that the complexes were most stable in the triplet spin state (S = 1), while, after interaction with carbon monoxide, the singlet state was most stable. The reactivity of the complexes was evaluated using HOMO-LUMO gap calculations. Parameter correlations were performed in order to identify the best complex for back bonding (3d xz Fe → 2p x C and 3d yz Fe → 2p z C) with carbon monoxide, and the degree of back bonding increased in the order: FeTNO 2 TAA < FeTClTAA < FeTOHTAA < FeTOCH 3 TAA < FeTNH 2 TAA.

  15. Acute carbon monoxide intoxication : the relation between MR findings and clinical outcome

    International Nuclear Information System (INIS)

    Chang, Jin Bae; Jeong, Hae Woong; Kim, Ki Nam; Kim, Dong Wook; Kim, Chang Soo

    1999-01-01

    To analyse MR findings of various involving sites and the relation between such findings and clinical outcome, the authors retrospectively reviewed MR images of acute carbon monoxide intoxication. In 12 patients, MR images obtained from several hours to 12 days after acute carbon monoxide intoxication were reviewed. The images were analysed with regard to involved sites, symmetricity, signal intensity, and the presence or absence of hemorrhage, and the relationship between MR findings and clinical outcome; the presence of delayed encephalopathy was then determined. The globus pallidus(n=9), white matter(n=3), [centrum semiovale(n=2), periventricular white matter(n=1)] and gyrus(n=6) [inferior temporal gyrus(n=2), cingulate gyrus(n=1), precentral gyrus(n=1), hippocampal gyrus(n=1), parahippocampal gyrus(n=1)] were typically involved, and there was also involvenent of the corpus callosum(n=3), thalamus(n=2) and midbrain(n=2). All lesions of the globus pallidus, thalamus, midbrain and temporal lobe were bilaterally symmetric. In all these cases, subtle or prominent low signal intensity was seen on spin-echo T1WI, and high signal intensity on PDWI and T2WI. Some lesions of the globus pallidus(n=1), thalamus(n=1) and midbrain(n=1) were associated with hemorrhage, which occurred during the early subacute stage and was seen on high/low signal intensity T1/T2WI images. Acute cerebral(n=1) and cerebellar(n=1) infarctions were also seen. Cerebral white matter involvement correlated with poor clinical outcome, and in two cases, delayed encephalopathy developed. In these cases of acute carbon monoxide intoxication, the globus pallidus, white matter, cortex and hippocampus were frequently involved, and there was also involvement of various sites such as the corpus callosum, thalamus and midbrain. Lesions of the temporal lobe, thalamus and midbrain were bilaterally symmetric. The involvement of cerebral white matter and the presence of delayed encephalopathy can influence

  16. Zinc-oxide nanorod / copper-oxide thin-film heterojunction for a nitrogen-monoxide gas sensor

    International Nuclear Information System (INIS)

    Yoo, Hwansu; Kim, Hyojin; Kim, Dojin

    2014-01-01

    A novel p - n oxide heterojunction structure was fabricated by employing n-type zinc-oxide (ZnO) nanorods grown on an indium-tin-oxide-coated glass substrate by using the hydrothermal method and a p-type copper-oxide (CuO) thin film deposited onto the ZnO nanorod array by using the sputtering method. The crystallinities and microstructures of the heterojunction materials were examined by using X-ray diffraction and scanning electron microscopy. The observed current - voltage characteristics of the p - n oxide heterojunction showed a nonlinear diode-like rectifying behavior. The effects of an oxidizing or electron acceptor gas, such as nitrogen monoxide (NO), on the ZnO nanorod/CuO thin-film heterojunction were investigated to determine the potential applications of the fabricated material for use in gas sensors. The forward current of the p - n heterojunction was remarkably reduced when NO gas was introduced into dry air at temperatures from 100 to 250 .deg. C. The NO gas response of the oxide heterojunction reached a maximum value at an operating temperature of 180 .deg. C and linearly increased as the NO gas concentration was increased from 5 to 30 ppm. The sensitivity value was observed to be as high as 170% at 180 .deg. C when biased at 2 V in the presence of 20-ppm NO. The ZnO nanorod/CuO thin-film heterojunction also exhibited a stable and repeatable response to NO gas. The experimental results suggest that the ZnO nanorod/CuO thin-film heterojunction structure may be a novel candidate for gas sensors.

  17. Zinc-oxide nanorod / copper-oxide thin-film heterojunction for a nitrogen-monoxide gas sensor

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hwansu; Kim, Hyojin; Kim, Dojin [Chungnam National University, Daejeon (Korea, Republic of)

    2014-11-15

    A novel p - n oxide heterojunction structure was fabricated by employing n-type zinc-oxide (ZnO) nanorods grown on an indium-tin-oxide-coated glass substrate by using the hydrothermal method and a p-type copper-oxide (CuO) thin film deposited onto the ZnO nanorod array by using the sputtering method. The crystallinities and microstructures of the heterojunction materials were examined by using X-ray diffraction and scanning electron microscopy. The observed current - voltage characteristics of the p - n oxide heterojunction showed a nonlinear diode-like rectifying behavior. The effects of an oxidizing or electron acceptor gas, such as nitrogen monoxide (NO), on the ZnO nanorod/CuO thin-film heterojunction were investigated to determine the potential applications of the fabricated material for use in gas sensors. The forward current of the p - n heterojunction was remarkably reduced when NO gas was introduced into dry air at temperatures from 100 to 250 .deg. C. The NO gas response of the oxide heterojunction reached a maximum value at an operating temperature of 180 .deg. C and linearly increased as the NO gas concentration was increased from 5 to 30 ppm. The sensitivity value was observed to be as high as 170% at 180 .deg. C when biased at 2 V in the presence of 20-ppm NO. The ZnO nanorod/CuO thin-film heterojunction also exhibited a stable and repeatable response to NO gas. The experimental results suggest that the ZnO nanorod/CuO thin-film heterojunction structure may be a novel candidate for gas sensors.

  18. Room-temperature cold-welding of gold nanoparticles for enhancing the electrooxidation of carbon monoxide.

    Science.gov (United States)

    Liu, Cai; Li, Yong-Jun; Sun, Shi-Gang; Yeung, Edward S

    2011-04-21

    A cold-welding strategy is proposed to rapidly join together Au nanoparticles (AuNPs) into two-dimensional continuous structures for enhancing the electrooxidation of carbon monoxide by injecting a mixture of ethanol and tolulene into the bottom of a AuNP solution. © The Royal Society of Chemistry 2011

  19. [Evaluation of changes in hemodynamic parameters after the use of electronic nicotine delivery systems among regular cigarette smokers].

    Science.gov (United States)

    Czogała, Jan; Cholewiński, Mateusz; Kutek, Agnieszka; Zielińska-Danch, Wioleta

    2012-01-01

    A relatively new device, described by producers as a device to help smokers quit, nicotine inhaler is an electronic (e-cigarette). Its mission is to provide the body with small doses of nicotine behavior "ceremonial" burning product is not tested for efficacy and toxicity The aim of this study was to compare the effects of nicotine absorbed from cigarette conventional and electronic changes in systolic and diastolic blood pressure and heart rate. Because of the potential interaction of carbon monoxide contained in cigarette smoke and nicotine conventional to changes on the parameters is also going to examine changes in the concentration of carboxyhemoglobin after smoking cigarettes and using e-cigarettes. study group consisted of 42 people, including 21 women and 21 men aged from 18 to 62 years who declared daily cigarette smoking. In this study it was found that as a result of cigarette smoking are increasing all the analyzed conventional hemodynamic parameters, these increases probably normally associated with nicotine absorbed by the smoker with the smoke. It was also a clear increase in carboxyhemoglobin, which is associated with a high concentration of carbon monoxide in cigarette smoke. If you use the e-cigarettes tested were observed increases in diastolic blood pressure and pulse, but none of the parameters did not change significantly, indicating that either the use of e-cigarette by the respondents did not supply the body with absorbable nicotine or for the increase in haemodynamic parameters studied did not correspond only nicotine but also other smoke constituents that interact with nicotine to the smoker body as carbon monoxide.

  20. Experimental study on surface wrinkling of silicon monoxide film on compliant substrate under thermally induced loads

    Science.gov (United States)

    Li, Chuanwei; Kong, Yingxiao; Jiang, Wenchong; Wang, Zhiyong; Li, Linan; Wang, Shibin

    2017-06-01

    The wrinkling of a silicon monoxide thin film on a compliant poly(dimethylsiloxane) (PDMS) substrate structure was experimentally investigated in this study. The self-expansion effect of PDMS during film deposition was utilized to impose a pretensile strain on the structure through a specially made fixture. A laser scanning confocal microscope (LSCM) system with an in situ heating stage was employed for the real-time measurement. The Young’s modulus of the silicon monoxide thin film as well as the PDMS substrate was measured on the basis of the elasticity theory. Moreover, the effects of temperature variations on geometric parameters in the postbuckling state, such as wavelength and amplitude, were analyzed. It was proved that wavelength is relatively immune to thermal loads, while amplitude is much more sensitive.

  1. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  2. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  3. Thermal Degradation of Lead Monoxide Filled Polymer Composite Radiation Shields

    International Nuclear Information System (INIS)

    Harish, V.; Nagaiah, N.

    2011-01-01

    Lead monoxide filled Isophthalate resin particulate polymer composites were prepared with different filler concentrations and investigated for physical, thermal, mechanical and gamma radiation shielding characteristics. This paper discusses about the thermo gravimetric analysis of the composites done to understand their thermal properties especially the effect of filler concentration on the thermal stability and degradation rate of composites. Pristine polymer exhibits single stage degradation whereas filled composites exhibit two stage degradation processes. Further, the IDT values as well as degradation rates decrease with the increased filler content in the composite.

  4. Chlorination of niobium oxide in the presence of carbon monoxide

    International Nuclear Information System (INIS)

    Freitas, L.R. de

    1984-01-01

    The chlorination kinetics of niobium pentoxide in the presence of carbon monoxide between 500-800 0 C of temperature is studied. The following variable that influences on the reaction rate are analysed: gas flow, geometry and volume of the Nb 2 O 5 samples, reaction temperature and composition of the chlorinated mixture. At the same time, two other materials were studied: the CaO.Nb 2 O 5 (synthetized in laboratory) and pyrochlorine concentrates. The three materials are compared for the chlorination method used. (M.A.C.) [pt

  5. Microbial fuel cell-based biosensor for toxic carbon monoxide monitoring

    DEFF Research Database (Denmark)

    Zhou, Shaofeng; Huang, Shaobin; Li, Yi

    2018-01-01

    This study presents an innovative microbial fuel cell-based biosensor for carbon monoxide (CO) monitoring. The hypothesis for the function of the biosensor is that CO inhibits bacterial activity in the anode and thereby reduces electricity production. A mature electrochemically active biofilm...... increasing CO concentration over 70%. Besides, the response time of the biosensor was 1 h. The compact design and simple operation of the biosensor makes it easy to be integrated in existing CO-based industrial facilities either as a forewarning sensor for CO toxicity or even as an individual on...

  6. Evidence for long-range transport of carbon monoxide in the Southern Hemisphere from SCIAMACHY observations

    NARCIS (Netherlands)

    Gloudemans, A.M.S.; Krol, M.C.; Meirink, J.F.; de Laat, A.T.J.; van der Werf, G.R.; Schrijver, H.; van den Broek, M.M.P.; Aben, I.

    2006-01-01

    The SCIAMACHY satellite instrument shows enhanced carbon monoxide (CO) columns in the Southern Hemisphere during the local Spring. Chemistry-transport model simulations using the new GFEDv2 biomass-burning emission database show a similar temporal and spatial CO distribution, indicating that the

  7. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    Science.gov (United States)

    2012-02-14

    ... a SIP means that transportation activities will not produce new air quality violations, worsen... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY... Transportation & Public Facilities, and the U.S. Department of Transportation will be required to use [[Page 8253...

  8. Exposure to carbon monoxide, respirable suspended particulates, and volatile organic compounds while commuting by bicycle

    International Nuclear Information System (INIS)

    Bevan, M.A.J.; Proctor, C.J.; Baker-Rogers, J.; Warren, N.D.

    1991-01-01

    A portable air sampling system has been used to assess exposures to various substances while commuting by bicycle in an urban area. The major source of pollutants in this situation is motor vehicle exhaust emissions. Carbon monoxide, measured by electrochemical detection, was found at peak concentrations in excess of 62 ppm, with mean values over 16 individual 35-mm journeys being 10.5 ppm. Respirable suspended particulates, averaged over each journey period, were found at higher concentrations (mean 130 μg m -3 ) than would be expected in indoor situations. Mean exposure to benzene (at 56 μg m -3 ) and other aromatic volatile organic compounds was also relatively high. The influence of wind conditions on exposure was found to be significant. Commuting exposures to carbon monoxide, respirable suspended particulates, and aromatic VOCs were found to be higher than exposures in a busy high street and on common parkland

  9. Nonfatal, unintentional, non--fire-related carbon monoxide exposures--United States, 2004-2006.

    Science.gov (United States)

    2008-08-22

    Carbon monoxide (CO) is a colorless, odorless, nonirritating gas that is produced through the incomplete combustion of hydrocarbons. Sources of CO include combustion devices (e.g., boilers and furnaces), motor-vehicle exhaust, generators and other gasoline or diesel-powered engines, gas space heaters, woodstoves, gas stoves, fireplaces, tobacco smoke, and various occupational sources. CO poisoning is a leading cause of unintentional poisoning deaths in the United States; it was responsible for approximately 450 deaths each year during 1999-2004 and an estimated 15,200 emergency department (ED) visits each year during 2001-2003. Health effects of CO exposure can range from viral-like symptoms (e.g., fatigue, dizziness, headache, confusion, and nausea) to more severe conditions (e.g., disorientation, unconsciousness, long-term neurologic disabilities, coma, cardiorespiratory failure, and death). CO poisoning often is misdiagnosed and underdetected because of the nonspecific nature of symptoms. To update a previously published report and provide national estimates of CO-related ED visits during 2004-2006, CDC analyzed data from the National Electronic Injury Surveillance System--All Injury Program (NEISS-AIP) database. During 2004-2006, an estimated average of 20,636 ED visits for nonfatal, unintentional, non-fire-related CO exposures occurred each year. Approximately 73% of these exposures occurred in homes, and 41% occurred during winter months (December-February). Prevention efforts targeting residential and seasonal CO exposures can substantially reduce CO-related morbidity.

  10. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Directory of Open Access Journals (Sweden)

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  11. UV-induced carbon monoxide emission from living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2013-01-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop...... to either an ecosystem chamber or a plant-leaf scale chamber. Leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation as well as the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature......, indicating an abiotic process. The emission of CO in response to the UV-component of natural solar radiation was also evident at the ecosystem scale....

  12. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    KAUST Repository

    Nasir, Ehson Fawad

    2018-05-07

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm at combustion relevant conditions. Off-axis alignment and rapid intra-pulse down-chirp resulted in effective suppression of cavity noise.

  13. Catalytic Reduction of Nitrous Oxide with Carbon Monoxide over Calcined Co–Mn–Al Hydrotalcite

    Czech Academy of Sciences Publication Activity Database

    Pacultová, K.; Obalová, L.; Kovanda, F.; Jirátová, Květa

    2008-01-01

    Roč. 137, 2-4 (2008), s. 358-389 ISSN 0920-5861 R&D Projects: GA ČR(CZ) GA106/05/0366 Institutional research plan: CEZ:AV0Z40720504 Keywords : nitrous oxide * carbon monoxide * mixed oxide catalysts Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.004, year: 2008

  14. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  15. Evidence for CO formation in irradiated methanol and acetone: contribution of low-energy electron-energy-loss spectroscopy to γ-radiolysis

    International Nuclear Information System (INIS)

    Jay-Gerin, J.-P.; Fraser, M.-J.; Michaud, M.; Sanche, L.; Swiderek, P.; Ferradini, C.

    1997-01-01

    Energy-loss spectra for low-energy electrons incident on acetone condensed on a multilayer film of argon, and on a methanol film deposited on a metallic substrate, are reported. In both cases, the formation of carbon monoxide has been detected. These results are directly related to those obtained in the liquid-phase γ-radiolysis of the two compounds. (author)

  16. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  17. Determining the diagnostic value of endogenous carbon monoxide in Chronic Obstructive Pulmonary Disease exacerbations

    International Nuclear Information System (INIS)

    Dogan, N. O.; Corbacioglu, S. K.; Bildik, F.; Kilicaslan, I.; Hakoglu, O.; Gunaydin, G. P.; Cevik, Y.; Ulker, V.; Gokcen, E.

    2014-01-01

    Objective: To determine whether endogenous carbon monoxide levels in exacerbations of Chronic Obstructive Pulmonary Disease patients were higher compared to healthy individuals and to investigate alteration of carbon monoxide levels across the three different severity stages of Global Initiative for Chronic Obstructive Lung Disease criteria related to Chronic Obstructive Pulmonary Disease exacerbations. Methods: The prospective study was conducted from January to March 2011 at two medical institutions in Ankara, Turkey, and comprised patients of acute Chronic Obstructive Pulmonary Disease exacerbations. The severity of the exacerbations was based on the Global Initiative for Chronic Obstructive Lung Disease criteria. Patients with active tobacco smoking, suspicious carbon monoxide poisoning and uncertain diagnosis were excluded. healthy control subjects who did not have any comorbid diseases and smoking habitus were also enrolled to compare the differences between carboxyhaemoglobin levels A two-tailed Mann-Whitney U test with Bonferroni correction was done following a Kruskal-Wallis test for statistical purposes. Results: There were 90 patients and 81 controls in the study. Carboxyhaemoglobin levels were higher in the patients than the controls (p<0.001). As for the three severity stages, Group 1 had a median carboxyhaemoglobin of 1.6 (0.95-2.00). The corresponding levels in Group 2 (1.8 (1.38-2.20)) and Group 3 (1.9 (1.5-3.0)) were higher than the controls (p<0.001 and p<0.005 respectively). No statistically significant difference between Group 1 and the controls (1.30 (1.10-1.55)) was observed (p<0.434). Conclusion: Carboxyhaemoglobin levels were significantly higher in exacerbations compared with the normal population. Also, in more serious exacerbations, carboxyhaemoglobin levels were significantly increased compared with healthy individuals and mild exacerbations. (author)

  18. Variations of time-to-incapacitation and carboxyhemoglobin values in rats exposed to two carbon monoxide concentrations.

    Science.gov (United States)

    1993-05-01

    It has been suggested that passenger protective breathing equipment protect aircraft passengers from smoke for 5 min during an evacuation phase and for 35 min during an in-flight-plus-evacuation phase. Carbon monoxide (CO) is one of the most abundant...

  19. Carbon monoxide budget in the northern hemisphere

    Energy Technology Data Exchange (ETDEWEB)

    Bakwin, P.S.; Tans, P.P. (Climate Monitoring and Diagnostics Lab., Boulder, CO (United States)); Novelli, P.C. (Univ. of Colorado, Boulder, CO (United States))

    1994-03-15

    To improve urban air quality the major industrialized nations of the West took steps during the 1970s and 1980s to reduce carbon monoxide (CO) emissions from automobiles and other industrial sources. Overall, CO/CO[sub 2] emission ratios from the mix of fossil fuel combustion sources have been reduced by about half during 1976-1990. Also, the tropospheric abundance of hydroxyl radical (OH), which is the main sink for CO, is proposed to have increased globally by about 1.0 [+-] 0.8% yr[sup [minus]1]. The authors use a simple two-box model to examine the impact of shrinking emissions and increasing OH on the global abundance of CO. They find that these factors contribute about equally in reducing CO levels in the Northern Hemisphere troposphere by about 1.8 [+-] 0.8 ppb yr[sup [minus]1] on average. 19 refs., 1 fig.

  20. Coupling of carbon monoxide molecules over oxygen-defected UO2(111) single crystal and thin film surfaces.

    Science.gov (United States)

    Senanayake, S D; Waterhouse, G I N; Idriss, H; Madey, Theodore E

    2005-11-22

    While coupling reactions of carbon-containing compounds are numerous in organometallic chemistry, they are very rare on well-defined solid surfaces. In this work we show that the reductive coupling of two molecules of carbon monoxide to C2 compounds (acetylene and ethylene) could be achieved on oxygen-defected UO2(111) single crystal and thin film surfaces. This result allows in situ electron spectroscopic investigation of a typical organometallic reaction such as carbon coupling and extends it to heterogeneous catalysis and solids. By using high-resolution photoelectron spectroscopy (HRXPS) it was possible to track the changes in surface states of the U and O atoms as well as identify the intermediate of the reaction. Upon CO adsorption U cations in low oxidation states are oxidized to U4+ ions; this was accompanied by an increase of the O-to-U surface ratios. The HRXPS C 1s lines show the presence of adsorbed species assigned to diolate species (-OCH=CHO-) that are most likely the reaction intermediate in the coupling of two CO molecules to acetylene and ethylene.

  1. Coupling of Carbon Monoxide Molecules over Oxygen Defected UO2 (111) Single Crystal and Thin Film Surfaces

    International Nuclear Information System (INIS)

    Senanayake, S.; Waterhouse, G.; Idriss, H.; Madey, T.

    2005-01-01

    While coupling reactions of carbon-containing compounds are numerous in organometallic chemistry, they are very rare on well-defined solid surfaces. In this work we show that the reductive coupling of two molecules of carbon monoxide to C 2 compounds (acetylene and ethylene) could be achieved on oxygen-defected UO 2 (111) single crystal and thin film surfaces. This result allows in situ electron spectroscopic investigation of a typical organometallic reaction such as carbon coupling and extends it to heterogeneous catalysis and solids. By using high-resolution photoelectron spectroscopy (HRXPS) it was possible to track the changes in surface states of the U and O atoms as well as identify the intermediate of the reaction. Upon CO adsorption U cations in low oxidation states are oxidized to U 4+ ions; this was accompanied by an increase of the O-to-U surface ratios. The HRXPS C 1s lines show the presence of adsorbed species assigned to diolate species (-OCH=CHO-) that are most likely the reaction intermediate in the coupling of two CO molecules to acetylene and ethylene

  2. Effect of Carbon Monoxide on Active Oxygen Metabolism of Postharvest Jujube

    OpenAIRE

    Shaoying Zhang; Qin Li; Yulan Mao

    2014-01-01

    To prolong the shelf life postharvest jujube, the effect of carbon monoxide (CO) on senescence of postharvest jujube in relation to active oxygen metabolism was investigated. Jujubes were fumigated with CO gas at 5, 10, 20 or 40μmol/L for 1 h, and then stored for 30 days at room temperature. Changes in membrane permeability, malonaldehyde (MDA), H2O2, O2•− content, and activities of active oxygen metabolism associated enzymes including superoxide dismutase (SOD), catalase (CAT) and peroxidase...

  3. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  4. Shaping the Electronic Library--The UW-Madison Approach.

    Science.gov (United States)

    Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David

    1998-01-01

    This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…

  5. A Southern Hemisphere atmospheric history of carbon monoxide from South Pole firn air

    Science.gov (United States)

    Verhulst, K. R.; Aydin, M.; Novelli, P. C.; Holmes, C. D.; Prather, M. J.; Saltzman, E. S.

    2013-12-01

    Carbon monoxide (CO) is a reactive trace gas and is important to tropospheric photochemistry as a major sink of hydroxyl radicals (OH). Major sources of CO are fossil fuel combustion, linked mostly to automotive emissions, biomass burning, and oxidation of atmospheric methane. Understanding changes in carbon monoxide over the past century will improve our understanding of man's influence on the reactivity of the atmosphere. Little observational information is available about CO levels and emissions prior to the 1990s, particularly for the Southern Hemisphere. The NOAA global flask network provides the most complete instrumental record of CO, extending back to 1988. Annually averaged surface flask measurements suggest atmospheric CO levels at South Pole were relatively stable from 2004-2009 at about 51 nmol mol-1 [Novelli and Masarie, 2013]. In this study, a 20th century atmospheric history of CO is reconstructed from South Pole firn air measurements, using a 1-D firn air diffusion model. Firn air samples were collected in glass flasks from two adjacent holes drilled from the surface to 118 m at South Pole, Antarctica during the 2008/2009 field season and CO analysis was carried out by NOAA/CCG. Carbon monoxide levels increase from about 45 nmol mol-1 in the deepest firn sample at 116 m to 52 nmol mol-1 at 107 m, and remain constant at about 51-52 nmol mol-1 at shallower depths. Atmospheric histories based on the firn air reconstructions suggest that CO levels over Antarctica increased by roughly 40% (from about 36 to 50 nmol mol-1) between 1930-1990, at a rate of about 0.18 nmol mol-1 yr-1. Firn air and surface air results suggest the rate of CO increase at South Pole slowed considerably after 1990. The firn air-based atmospheric history is used to infer changes in Southern Hemisphere CO emissions over the 20th century.

  6. Impact of carbon monoxide partial pressures on methanogenesis and medium chain fatty acids production during ethanol fermentation.

    Science.gov (United States)

    Esquivel-Elizondo, Sofia; Miceli, Joseph; Torres, Cesar I; Krajmalnik-Brown, Rosa

    2018-02-01

    Medium-chain fatty acids (MCFA) are important biofuel precursors. Carbon monoxide (CO) is a sustainable electron and carbon donor for fatty acid elongation, since it is metabolized to MCFA precursors, it is toxic to most methanogens, and it is a waste product generated in the gasification of waste biomass. The main objective of this work was to determine if the inhibition of methanogenesis through the continuous addition of CO would lead to increased acetate or MCFA production during fermentation of ethanol. The effects of CO partial pressures (P CO ; 0.08-0.3 atm) on methanogenesis, fatty acids production, and the associated microbial communities were studied in batch cultures fed with CO and ethanol. Methanogenesis was partially inhibited at P CO  ≥ 0.11 atm. This inhibition led to increased acetate production during the first phase of fermentation (0-19 days). However, a second addition of ethanol (day 19) triggered MCFA production only at P CO  ≥ 0.11 atm, which probably occurred through the elongation of acetate with CO-derived ethanol and H 2 :CO 2 . Accordingly, during the second phase of fermentation (days 20-36), the distribution of electrons to acetate decreased at higher P CO , while electrons channeled to MCFA increased. Most probably, Acetobacterium, Clostridium, Pleomorphomonas, Oscillospira, and Blautia metabolized CO to H 2 :CO 2 , ethanol and/or fatty acids, while Peptostreptococcaceae, Lachnospiraceae, and other Clostridiales utilized these metabolites, along with the provided ethanol, for MCFA production. These results are important for biotechnological systems where fatty acids production are preferred over methanogenesis, such as in chain elongation systems and microbial fuel cells. © 2017 Wiley Periodicals, Inc.

  7. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  8. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Science.gov (United States)

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  9. Carbon monoxide (CO) intoxication: Computerized tomography and magnetic resonance

    International Nuclear Information System (INIS)

    Benitez Gomez, S.; Aguilera Navarro, J.M.; Gonzalez Garcia, A.; Gonzalez Marcos, J.R.; Fernandez Cruz, J.

    1993-01-01

    We present a case of acute carbon monoxide (CO) intoxication in a previously healthy 13-year-old girl, who was found in the bathroom, unconscious and with the gas-burning hot water thank operating. The neuroradiological study showed bilateral, symmetrical cortical and subcortical parietooccipital and temporal lesions as well as damage to the basal lymph nodes. These lesions were related to the anoxic situation induced by this type of intoxication. Clinicoradiological follow-up included CT and MR sequences over a period of 10 months. In this cases, we stress the greater sensitivity of MR in the early detection of the characteristic lesions in this situation and we analyze the evolution of the process. (Author)

  10. Electrocatalytic oxidation of carbon monoxide

    Directory of Open Access Journals (Sweden)

    Manuel de Jesus Santiago Farias

    2009-01-01

    Full Text Available Este trabalho discute alguns aspectos importantes relacionados à reação de eletrooxidação do monóxido de carbono sobre monocristais de platina, em meio ácido. Aspectos mecanísticos são discutidos em termos da formação das estruturas compactas que o CO forma quando este é adsorvido. As principais idéias aqui apresentadas, levam em consideração as existências dessas estruturas. Os clássicos mecanismos Lagmuir-Hinshelwood e Eley-Rideal são aqui discutidos, especialmente o primeiro considerando a mobilidade do CO e também a nucleação e crescimento de ilhas formadas por espécies adsorvidas contendo oxigênio.////////// This work discusses some important aspects related to the carbon monoxide electrooxidation reaction on Pt single crystal electrodes in acidic media. The mechanistic aspects are discussed in terms of the formation of compact structures developed when CO is adsorbed. The main ideas presented here are focused on the mechanistic aspects that take into account the existence of such structures. The classical kinetic mechanisms of Lagmuir-Hinshelwood and Eley-Rideal are discussed considering the superficial mobility of CO or nucleation-growing of islands formed by oxygen-containing adsorbates.

  11. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Directory of Open Access Journals (Sweden)

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  12. Synthesis of one-dimensional metal-containing insulated molecular wire with versatile properties directed toward molecular electronics materials.

    Science.gov (United States)

    Masai, Hiroshi; Terao, Jun; Seki, Shu; Nakashima, Shigeto; Kiguchi, Manabu; Okoshi, Kento; Fujihara, Tetsuaki; Tsuji, Yasushi

    2014-02-05

    We report, herein, the design, synthesis, and properties of new materials directed toward molecular electronics. A transition metal-containing insulated molecular wire was synthesized through the coordination polymerization of a Ru(II) porphyrin with an insulated bridging ligand of well-defined structure. The wire displayed not only high linearity and rigidity, but also high intramolecular charge mobility. Owing to the unique properties of the coordination bond, the interconversion between the monomer and polymer states was realized under a carbon monoxide atmosphere or UV irradiation. The results demonstrated a high potential of the metal-containing insulated molecular wire for applications in molecular electronics.

  13. Electronic resources access and usage among the postgraduates of ...

    African Journals Online (AJOL)

    ... and usage among the postgraduates of a Nigerian University of Technology. ... faced by postgraduates in using e-resources include takes too much time to find, ... Resources, Access, Use, Postgraduat, Students, University, Technology, Nigeria ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  14. [Estimation of carbon monoxide poisonings frequency, based on carboxyhemoglobin determinations performed in Toxicology Laboratory in Krakow in years 2002-2010].

    Science.gov (United States)

    Gomółka, Ewa; Gawlikowski, Tomasz

    2011-01-01

    Carboxyhemoglobin is a specific biomarker of carbon monoxide (CO) exposition. The source of CO indoors are most often gas, oil or carbon furnaces and stoves or bathroom gas heaters. CO intoxication during fire or exposition to car fumes are sporadic. The aim of the study was: to present the frequency of CO intoxications diagnosed in Laboratory of Analytical Toxicology UJ Collegium Medicum in years 2002 - 2010, to present the season trends of CO intoxications, show sex and age structure of CO intoxicated patients. Material were Laboratory of Analytical Toxicology and Drug Monitoring data records from years 2002 - 2010. CO intoxication was confirmed and recognized when COHb blood concentration was higher than 10%. Annual number of CO poisonings was stable in the period of time, varied from 209 to 296 (mean 256,2 CO poisonings per year). Sex structure of CO poisoned patients showed little female dominance (54.6%). Carbon monoxide poisonings distribution was seasonal. The season of intensified CO intoxications lasted from October to March, the highest intensity was in December and January. The CO poisoning problem is still actual. Society education about security, recognition, diagnosis and practice in carbon monoxide exposition is still needful.

  15. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  16. Ambient carbon monoxide associated with alleviated respiratory inflammation in healthy young adults

    International Nuclear Information System (INIS)

    Zhao, Zhuohui; Chen, Renjie; Lin, Zhijing; Cai, Jing; Yang, Yingying; Yang, Dandan; Norback, Dan; Kan, Haidong

    2016-01-01

    There is increasing controversy on whether acute exposure to ambient carbon monoxide (CO) is hazardous on respiratory health. We therefore performed a longitudinal panel study to evaluate the acute effects of ambient CO on fractional exhaled nitric oxide (FeNO), a well-established biomarker of airway inflammation. We completed 4–6 rounds of health examinations among 75 healthy young adults during April to June in 2013 in Shanghai, China. We applied the linear mixed-effect model to investigate the short-term associations between CO and FeNO. CO exposure during 2–72 h preceding health tests was significantly associated with decreased FeNO levels. For example, an interquartile range increase (0.3 mg/m"3) of 2-h CO exposure corresponded to 10.6% decrease in FeNO. This association remained when controlling for the concomitant exposure to co-pollutants. This study provided support that short-term exposure to ambient CO might be related with reduced levels of FeNO, a biomarker of lower airway inflammation. - Highlights: • We completed 4–6 rounds of health examinations among 75 healthy young adults. • Short-term CO exposure was significantly associated with decreased FeNO levels. • The inverse association between CO and FeNO was robust controlling for co-pollutants. - Short-term exposure to ambient carbon monoxide may alleviate the respiratory inflammation.

  17. IR Laser Ablation of Silicon Monoxide in Gaseous Methanol and Hydrocarbons: Deposition of Polyoxocarbosilane

    Czech Academy of Sciences Publication Activity Database

    Dřínek, Vladislav; Bastl, Zdeněk; Šubrt, Jan; Pola, Josef

    2004-01-01

    Roč. 71, č. 2 (2004), s. 431-444 ISSN 0165-2370 R&D Projects: GA ČR GA203/00/1288 Institutional research plan: CEZ:AV0Z4072921; CEZ:AV0Z4032918; CEZ:AV0Z4040901 Keywords : silicon monoxide * reactive laser ablation * polyoxocarbosilane coatings Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 1.352, year: 2004

  18. EFFECTIVE ELECTRONIC TUTORIAL

    Directory of Open Access Journals (Sweden)

    Andrei A. Fedoseev

    2014-01-01

    Full Text Available The article analyzes effective electronic tutorials creation and application based on the theory of pedagogy. Herewith the issues of necessary electronic tutorial functional, ways of the educational process organization with the use of information and communication technologies and the logistics of electronic educational resources are touched upon. 

  19. Carbon monoxide inhibits omega-oxidation of leukotriene B4 by human polymorphonuclear leukocytes: evidence that catabolism of leukotriene B4 is mediated by a cytochrome P-450 enzyme.

    Science.gov (United States)

    Shak, S; Goldstein, I M

    1984-09-17

    Carbon monoxide significantly inhibits omega-oxidation of exogenous leukotriene B4 to 20-OH-leukotriene B4 and 20-COOH-leukotriene B4 by unstimulated polymorphonuclear leukocytes as well as omega-oxidation of leukotriene B4 that is generated when cells are stimulated with the calcium ionophore, A23187. Inhibition of omega-oxidation by carbon monoxide is concentration-dependent, completely reversible, and specific. Carbon monoxide does not affect synthesis of leukotriene B4 by stimulated polymorphonuclear leukocytes or other cell functions (i.e., degranulation, superoxide anion generation). These findings suggest that a cytochrome P-450 enzyme in human polymorphonuclear leukocytes is responsible for catabolizing leukotriene B4 by omega-oxidation.

  20. Content of carbon monoxide in the tissues of rats intoxicated with carbon monoxide in various conditions of acute exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sokal, J.A.; Majka, J.; Palus, J.

    1984-12-01

    Tissue carbon monoxide (CO) content was investigated in rats severely intoxicated with CO under various exposure conditions: 1% CO for 4 min, 0.4% CO for 40 min and 0.12% CO for 12 h. Extravascular CO was determined in the heart and skeletal muscles immediately after termination of exposure, and carboxymyoglobin (MbCO) percent saturation was calculated. Total brain CO was estimated immediately after termination of exposure and after the time periods of restitution. After the same exposure conditions, MbCO percent saturation was higher in the heart than in skeletal muscle. In both types of muscle, saturation on myoglobin (Mb) with CO depended on blood carboxyhemoglobin (HbCO) level and not on the duration of exposure. The time course of CO elimination was the same for blood and brain, irrespective of CO exposure conditions. The results obtained showed that acute CO intoxication induced by long duration exposures did not involve CO accumulation in the tissues.

  1. Thermodynamic properties of liquid mixtures of carbon monoxide and methane

    Energy Technology Data Exchange (ETDEWEB)

    Calado, J.C.G.; Guedes, H.J.R.; Nunes da Ponte, M.; Streett, W.B.

    1984-04-01

    Researchers conducted pressure-volume-temperature measurements of liquid methane at -230/sup 0/F and of six liquid mixtures of carbon monoxide and methane at -250/sup 0/, -240/sup 0/, and -230/sup 0/F from just above the saturation vapor pressure to the freezing pressure of methane. The excess volume proved to be large and negative at low pressures but less negative as the pressure increased, being almost zero at the highest pressure. Of the thermodynamic functions, excess enthalpy and excess entropy were much more sensitive to pressure than excess Gibbs energy. Conformal solution theory in the van der Waals one-fluid form reproduced the experimental results very successfully.

  2. Analysis of carbon monoxide production in multihundred-watt heat sources

    International Nuclear Information System (INIS)

    Peterson, D.E.; Mulford, R.N.R.

    1976-05-01

    The production of carbon monoxide observed within Multihundred Watt heat sources placed under storage conditions was analyzed. Results of compositional and isotopic analyses of gas taps performed on eight heat sources are summarized and interpreted. Several proposed CO generation mechanisms are examined theoretically and assessed by applying thermodynamic principles. Outgassing of the heat source graphite followed by oxygen isotopic exchange through the vent assemblies appears to explain the CO production at storage temperatures. Reduction of the plutonia fuel sphere by the CO is examined as a function of temperature and stoichiometry. Experiments that could be performed to investigate possible CO generation mechanisms are discussed

  3. Characteristics of autoignited laminar lifted flames in heated coflow jets of carbon monoxide/hydrogen mixtures

    KAUST Repository

    Choi, Byungchul

    2012-06-01

    The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process. © 2012 The Korean Society of Mechanical Engineers.

  4. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 1 (SRL1) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  5. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide Second by Second data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  6. Renewable energy resources

    DEFF Research Database (Denmark)

    Ellabban, Omar S.; Abu-Rub, Haitham A.; Blaabjerg, Frede

    2014-01-01

    Electric energy security is essential, yet the high cost and limited sources of fossil fuels, in addition to the need to reduce greenhouse gasses emission, have made renewable resources attractive in world energy-based economies. The potential for renewable energy resources is enormous because...... they can, in principle, exponentially exceed the world's energy demand; therefore, these types of resources will have a significant share in the future global energy portfolio, much of which is now concentrating on advancing their pool of renewable energy resources. Accordingly, this paper presents how...... renewable energy resources are currently being used, scientific developments to improve their use, their future prospects, and their deployment. Additionally, the paper represents the impact of power electronics and smart grid technologies that can enable the proportionate share of renewable energy...

  7. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Directory of Open Access Journals (Sweden)

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  8. Selective and efficient reduction of carbon dioxide to carbon monoxide on oxide-derived nanostructured silver electrocatalysts

    NARCIS (Netherlands)

    Ma, Ming; Trześniewski, Bartek J.; Xie, Jie; Smith, Wilson A.

    2016-01-01

    In this work, the selective electrocatalytic reduction of carbon dioxide to carbon monoxide on oxide-derived silver electrocatalysts is presented. By a simple synthesis technique, the overall high faradaic efficiency for CO production on the oxide-derived Ag was shifted by more than 400 mV towards a

  9. Toxicity of carbon monoxide hydrogen cyanide gas mixtures : exposure concentration, time to incapacitation, carboxyhemoglobin and blood cyanide parameters.

    Science.gov (United States)

    1994-04-01

    During aircraft interior fires, carbon monoxide (CO) and hydrogen cyanide (HCN) are produced in sufficient amounts to cause incapacitation and death. Time-to-incapacitation (ti) is a practical parameter for estimating escape time in fire environments...

  10. Carbon monoxide and coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Scheidemandel, V

    1974-01-01

    Studies on the relationship between increased carboxyhemoglobin levels in the blood and coronary heart disease in smokers and city dwellers are reviewed. The evidence of myocardial infarction is significantly higher in smokers than in nonsmokers which is due, apart from nicotine which promotes coronary arteriosclerosis, to inhaled carbon monoxide which leads to increased carboxyhemoglobin levels and most likely plays a role in the risk of arteriosclerosis and the coronary heart disease. Apart from combining with hemoglobin, CO increases the circulation rate and the coronary blood flow, and reduces the coronary arteriovenous oxygen difference, which is indicative of a reduced rate of oxygen extraction by the myocardium against an increased myocardial oxygen demand. The reduction of the oxygen extraction correlates with the increased COHb level. Inhaled CO lowers the threshold of angina pectoris due to the reduced myocardial oxygen tension. Also, considerable reduction of the oxygen diffusion from the capillaries toward the mitochondria due to the combination of CO with myoglobin is observed. Chronically increased CO levels in the blood and tissues not only accelerate the development of arteriosclerosis, but also induce a process directly injurious to the myocardial metabolism. (Air Pollut. Abstr.)

  11. Carbon Monoxide: An Essential Signalling Molecule

    Science.gov (United States)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  12. Regional and hemispheric influences on temporal variability in baseline carbon monoxide and ozone over the Northeast US

    Science.gov (United States)

    Interannual variability in baseline carbon monoxide (CO) and ozone (O3), defined as mixing ratios under minimal influence of recent and local emissions, was studied for seven rural sites in the Northeast US over 2001–2010. Annual baseline CO exhibited statistically signific...

  13. Satellite observations of tropospheric ammonia and carbon monoxide: Global distributions, regional correlations and comparisons to model simulations

    Science.gov (United States)

    Ammonia (NH3) and carbon monoxide (CO) are primary pollutants emitted to the Earth's atmosphere from common as well as distinct sources associated with anthropogenic and natural activities. The seasonal and global distributions and correlations of NH3 and CO from the Tropospheric...

  14. Atomic hydrogen and diatomic titanium-monoxide molecular spectroscopy in laser-induced plasma

    Science.gov (United States)

    Parigger, Christian G.; Woods, Alexander C.

    2017-03-01

    This article gives a brief review of experimental studies of hydrogen Balmer series emission spectra. Ongoing research aims to evaluate early plasma evolution following optical breakdown in laboratory air. Of interest is as well laser ablation of metallic titanium and characterization of plasma evolution. Emission of titanium monoxide is discussed together with modeling of diatomic spectra to infer temperature. The behavior of titanium particles in plasma draws research interests ranging from the modeling of stellar atmospheres to the enhancement of thin film production via pulsed laser deposition.

  15. Zatrucie tlenkiem węgla – drogi narażenia, obraz kliniczny, metody leczenia = Carbon monoxide poisoning, routes of exposure, clinical manifestation, treatment

    Directory of Open Access Journals (Sweden)

    Magdalena Sowa

    2015-04-01

    owa kluczowe: tlenek węgla, zatrucie, hipoksja.   Abstract   Introduction: Carbon monoxide (CO is a colorless, odorless, non-irritating and toxic gas, undetectable by the sense organs. CO is a product of incomplete combustion of substances containing hydrocarbon products (industrial gas, coal, wood. Carbon monoxide is one of the most common causes of poisoning inhalation in the world. Aim of the study: The aim of this study was to analyze the routes of exposure, clinical manifestation and treatment of carbon monoxide poisoning. Brief overview of the state of knowledge: The toxicity of carbon monoxide is strongly associated with its high affinity for hemoglobin (approximately 200 times greater than the oxygen. The heart and central nervous system (CNS are the most vulnerable to CO. Pathomechanism of action involves binding of carbon monoxide with iron atom in the heme molecule to form a compound called carboxyhemoglobin (COHb. Inhaling carbon monoxide-rich air may cause anoxia. The oxidative metabolic processes are inhibited. Accumulation of acidic metabolites cause the enlargement of the cerebral arteries and consequently hyperemia of the brain. Summary: The amount of carbon monoxide poisoning in Poland is higher than in other European countries. Significant decrease mortality for carbon monoxide poisoning has observed over the last few years. Thousands of patients who lose their health and  their lives, should cause the attention to the effectiveness of preventive measures.   Keywords: carbon monoxide, poisoning, hypoxia.

  16. Metal cluster cation reactions: Carbon monoxide association to Cu + n ions

    Science.gov (United States)

    Leuchtner, R. E.; Harms, A. C.; Castleman, A. W., Jr.

    1990-06-01

    Copper cluster cations (Cu+n,n=1-14) were produced in a laser vaporization/flow tube apparatus and equilibrated to room temperature. The association rate constants of carbon monoxide onto these ions were measured; low-pressure, termolecular behavior was observed for the smaller species while for clusters greater than Cu+7, the longer lifetimes due to the increased number of degrees of freedom leads to pressure independence (>0.3 Torr) of the effective bimolecular rates. Unimolecular decay theory (RRKM) is used to explain the overall trend and when intrinsic surface site reactivity is taken into account, excellent agreement with measured reactivity is obtained.

  17. Gas Sensing Properties of NiSb2O6 Micro- and Nanoparticles in Propane and Carbon Monoxide Atmospheres

    Directory of Open Access Journals (Sweden)

    Verónica-M. Rodríguez-Betancourtt

    2017-01-01

    Full Text Available Micro- and nanoparticles of NiSb2O6 were synthesized by the microwave-assisted colloidal method. Nickel nitrate, antimony chloride, ethylenediamine, and ethyl alcohol were used. The oxide was obtained at 600°C and was analyzed by X-ray diffraction (XRD and Raman spectroscopy, showing a trirutile-type structure with cell parameters a = 4.641 Å, c = 9.223 Å, and a space group P42/mnm (136. Average crystal size was estimated at ~31.19 nm, according to the XRD-peaks. The microstructure was scrutinized by scanning electron microscopy (SEM, observing microrods measuring ~3.32 μm long and ~2.71 μm wide, and microspheres with an average diameter of ~8 μm; the size of the particles shaping the microspheres was measured in the range of ~0.22 to 1.8 μm. Transmission electron microscopy (TEM revealed that nanoparticles were obtained with sizes in the range of 2 to 20 nm (~10.7 nm on average. Pellets made of oxide’s powders were tested in propane (C3H8 and carbon monoxide (CO atmospheres at different concentrations and temperatures. The response of the material increased significantly as the temperature and the concentration of the test gases rose. These results show that NiSb2O6 may be a good candidate for gas sensing applications.

  18. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.

  19. Lethal carbon monoxide toxicity in a concrete shower unit.

    Science.gov (United States)

    Heath, Karen; Byard, Roger W

    2018-05-23

    A 47-year-old previously-well woman was found dead on the floor of a shower cubicle on a property in rural South Australia. The impression of the attending doctor and police was of collapse due to natural disease. Although there was significant stenosing coronary artery atherosclerosis found at autopsy, cherry pink discoloration of tissues prompted measurement of the blood carboxyhemoglobin level which was found to be 55%. The source of the gas was a poorly-maintained hot water heater that was mounted on the inside wall of the shower. Construction of the shower using an impermeable concrete rain water tank had caused gas accumulation when the water heater malfunctioned. Had lethal carbon monoxide exposure not been identified others using the same shower unit would also have been at risk.

  20. Electronic resources of the rare books and valuable editions department of the Central Scientific Library of the V.N. Karazin Kharkiv National University: open access for research

    Directory of Open Access Journals (Sweden)

    І. К. Журавльова

    2014-12-01

    Full Text Available The article describes tasks that electronic collections of rare books fulfill: broad access for readers to rare and valuable editions providing, preservation of ensuring of the original. On the example of the electronic collection of the Central Scientific Library of the V.N. Karazin Kharkiv National University – «eScriptorium: electronic archive of rare books and manuscripts for research and education» the possibility of the full-text resources of the valuable editions using is shown. The principles of creation, structure, chronological frameworks, directions of adding the documents to the archive are represented. The perspectives of the project development are outlined as well as examples of the digital libraries of the European countries and Ukraine are provided, the actual task of preserving the originals of the rare books of the country is raised, the innovative approaches to serving users with electronic resources are considered. The evidences of cooperation of the Central Scientific Library of the V.N. Karazin Kharkiv National University with the largest world digital libraries: World Digital Library and Europeana are provided.

  1. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  2. Electronic tracking of human resource skills and knowledge, just in time training, manageable due diligence

    Energy Technology Data Exchange (ETDEWEB)

    Kolodziej, M.A. [Quick Test International Inc., (Canada). Canadian Technology Human Resource Board; Baker, O. [KeySpan Energy Canada, Calgary, AB (Canada)

    2001-06-01

    KeySpan Energy Canada is in the process of obtaining recognition of various occupational profiles including pipeline operators, inspectors, and field and plant operators from various certifying organizations. The process of allowing individuals to obtain certification is recognized by Canadian Technology Human Resources Board as a step towards national standards for technologists and technicians. Proven competency is a must for workers in todays oil industry in response to increasingly stringent government safety regulations, environmental concerns and high public scrutiny. Quick Test international Inc. has developed a management tool in collaboration with end users at KeySpan Energy Canada. It is an electronic, Internet based competency tool for tracking personal competencies and maintaining continued competency. Response to the tool has been favourable. 2 refs., 4 figs.

  3. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    Science.gov (United States)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    Science.gov (United States)

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  5. Electrocardiographic Findings and Serum Troponin I in Carbon Monoxide Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Scott Reza Jafarian Kerman

    2012-03-01

    Full Text Available Carbon monoxide (CO poisoning, though with different sources, is one of the most deadly emergencies in all countries. CO can threaten men's life by several paths especially cardiac complications, which can mimic other cardiac problems such as myocardial infarction. The objective of this study was to determine ECG findings and serum troponin I levels in CO poisoned patients. In this analytical cross-sectional study, 63 CO poisoning patients were consecutively included from hospital's emergency departments. CO content was measured by a CO-oximeter and an electrocardiography was taken first thing on admission. Arterial blood gas (ABG, troponin I and other data was collected afterwards. Data were divided by age groups (adults and children and gender. CO content was significantly higher only in subjects with normal T wave compared to patients with inverted T wave in their initial ECG (P=0.016. No other significant difference was noticed. None of the ABG findings correlated significantly with CO content. Also no significant correlation was found with CO content after stratification by gender and age groups, but pH in children (r=-0.484, P=0.026. CO content was significantly higher in adults (P=0.023, but other ABG data were not significantly different. Only 3 patients had elevated troponin I. Receiver operating characteristic (ROC analysis showed no significant cutoff points in CO content for ECG changes. No significant specific change in electrocardiograms (ECG could contribute carboxyhemoglobin content in carbon monoxide poisoned patients. In addition, no specific difference was found between adults and pediatric subjects' ECGs. All other findings seemed to be accidental.

  6. Development of CuxFe/Al2O3 catalysts for the hydrogenation of carbon monoxide guided by magnetic methods, Moessbauer and infrared spectroscopy

    International Nuclear Information System (INIS)

    Boellaard, E.; Geus, J.W.; Bruggen, J.M. van; Kraan, A.M. van der

    1993-01-01

    A copper-iron catalyst for the hydrogenation of carbon monoxide has been prepared using a supported stoichiometric cyanide complex. Conversion of the cyanide precursor to a metallic catalyst appeared to be a precious process. Copper and iron in the bimetallic particles easily separate by thermal treatment and upon exposure to carbon monoxide, as revealed from Moessbauer and infrared spectroscopy. During Fischer-Tropsch reaction the catalyst exhibits a rapid decline of activity. Magnetisation measurements on spent catalysts indicate that the deactivation is caused by a fast conversion of metallic iron to initially unstable carbides which transform ultimately to more stable carbides. (orig.)

  7. The Biomedical Resource Ontology (BRO) to enable resource discovery in clinical and translational research.

    Science.gov (United States)

    Tenenbaum, Jessica D; Whetzel, Patricia L; Anderson, Kent; Borromeo, Charles D; Dinov, Ivo D; Gabriel, Davera; Kirschner, Beth; Mirel, Barbara; Morris, Tim; Noy, Natasha; Nyulas, Csongor; Rubenson, David; Saxman, Paul R; Singh, Harpreet; Whelan, Nancy; Wright, Zach; Athey, Brian D; Becich, Michael J; Ginsburg, Geoffrey S; Musen, Mark A; Smith, Kevin A; Tarantal, Alice F; Rubin, Daniel L; Lyster, Peter

    2011-02-01

    The biomedical research community relies on a diverse set of resources, both within their own institutions and at other research centers. In addition, an increasing number of shared electronic resources have been developed. Without effective means to locate and query these resources, it is challenging, if not impossible, for investigators to be aware of the myriad resources available, or to effectively perform resource discovery when the need arises. In this paper, we describe the development and use of the Biomedical Resource Ontology (BRO) to enable semantic annotation and discovery of biomedical resources. We also describe the Resource Discovery System (RDS) which is a federated, inter-institutional pilot project that uses the BRO to facilitate resource discovery on the Internet. Through the RDS framework and its associated Biositemaps infrastructure, the BRO facilitates semantic search and discovery of biomedical resources, breaking down barriers and streamlining scientific research that will improve human health. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. Electronic Recruitment at CERN

    CERN Multimedia

    2004-01-01

    The Human Resources Department switches to electronic recruitment. From now on whenever you are involved in a recruitment action you will receive an e-mail giving you access to a Web folder. Inside you will find a shortlist of applications drawn up by the Human Resources Department. This will allow you to consult the folder, at the same time as everyone else involved in the recruitment process, for the vacancy you are interested in. This new electronic recruitment system, known as e-RT, will be introduced in a presentation given at 10 a.m. on 11 February in the Main Auditorium. Implemented by AIS (Administrative Information Services) and the Human Resources Department, e-RT will cover vacancies open in all of CERN's recruitment programmes. The electronic application system was initially made available to technical students in July 2003. By December it was extended to summer students, fellows, associates and Local Staff. Geraldine Ballet from the Recruitment Service prefers e-RT to mountains of paper! The Hu...

  9. Carbon Monoxide Hydrogenation on Ice Surfaces.

    Science.gov (United States)

    Kuwahata, Kazuaki; Ohno, Kaoru

    2018-03-14

    We have performed density functional calculations to investigate the carbon monoxide hydrogenation reaction (H+CO→HCO), which is important in interstellar clouds. We found that the activation energy of the reaction on amorphous ice is lower than that on crystalline ice. In the course of this study, we demonstrated that it is roughly possible to use the excitation energy of the reactant molecule (CO) in place of the activation energy. This relationship holds also for small water clusters at the CCSD level of calculation and the two-layer-level ONIOM (CCSD : X3LYP) calculation. Generally, since it is computationally demanding to estimate activation energies of chemical reactions in a circumstance of many water molecules, this relationship enables one to determine the activation energy of this reaction on ice surfaces from the knowledge of the excitation energy of CO only. Incorporating quantum-tunneling effects, we discuss the reaction rate on ice surfaces. Our estimate that the reaction rate on amorphous ice is almost twice as large as that on crystalline ice is qualitatively consistent with the experimental evidence reported by Hidaka et al. [Chem. Phys. Lett., 2008, 456, 36.]. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Influence of solvent on the infared spectrum of carbon monoxide adsorbed on platinum electrodes

    OpenAIRE

    Feltovich, Susanne D.

    1993-01-01

    The behavior of adsorbed carbon monoxide on platinum was studied using potential difference infrared spectroscopy. Three solvents and three electrolytes were chosen, and data gathered at both high and low adsorbate coverages. The rate of change of IR peak position with applied potential, the Stark tuning rate, was used as an indicator of the local electric field strength at the interface. It was determined that neither solvated cation size nor bulk dielectric constant accoun...

  11. Subclinical carbon monoxide poisoning in our health area

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, I.G.; Testa, A.F.; Sangrador, C.O.; Garcia, M.T.A.; Berrocal, J.L.S.; Pastor, N.R.; Martin, J.M.; Garcia, L.S.; Garcia, M.C.F.; Maire-Richard, E.G. [Hospital of Virgen Concha, Zamora (Spain)

    2003-08-01

    We present an observation study on the relationship between high levels of carboxyhemoglobin (COHB) and subclinical poisoning by carbon monoxide (CO) in our health area. The study was carried out in February and March 2000 in 228 over 18-year-old patients of both sexes who went to the Emergency Room for various reasons. After an informed consent was conceded, a venous blood sample was obtained in order to determine the level of COHB; later, we collected the anthropometric data, the data relative to the tobacco use, and the data of the type of heating at home. The values limit of the COHB obtained were the following: in non smokers, 1.9%; in 1-10 cigarettes/day smokers, 5.2%; in 11-20 cigarettes/day smokers, 6.9%; in {gt}20 cigarettes/day smokers, 9.6%. A COHB high level was observed in 25% of the patients regardless of the smoking habits, being the coal-dust slack brazier the source of most frequent exposure to CO.

  12. Detection of the J = 6→5 transition of carbon monoxide

    International Nuclear Information System (INIS)

    Goldsmith, P.F.; Erickson, N.R.; Fetterman, H.R.; Clifton, B.J.; Peck, D.D.; Tannenwald, P.E.; Koepf, G.A.; Buhl, D.; McAvoy, N.

    1981-01-01

    The J = 6→5 rotational transition of carbon monoxide has been detected in emission from the KL ''plateau source'' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km s -1 . These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. Our data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approx.180 K

  13. Plastics disassembly versus bulk recycling: engineering design for end-of-life electronics resource recovery.

    Science.gov (United States)

    Rios, Pedro; Stuart, Julie Ann; Grant, Ed

    2003-12-01

    Annual plastic flows through the business and consumer electronics manufacturing supply chain include nearly 3 billion lb of high-value engineering plastics derived from petroleum. The recovery of resource value from this stream presents critical challenges in areas of materials identification and recycling process design that demand new green engineering technologies applied together with life cycle assessment and ecological supply chain analysis to create viable plastics-to-plastics supply cycles. The sustainable recovery of potentially high-value engineering plastics streams requires that recyclers either avoid mixing plastic parts or purify later by separating smaller plastic pieces created in volume reduction (shredding) steps. Identification and separation constitute significant barriers in the plastics-to-plastics recycling value proposition. In the present work, we develop a model that accepts randomly arriving electronic products to study scenarios by which a recycler might identify and separate high-value engineering plastics as well as metals. Using discrete eventsimulation,we compare current mixed plastics recovery with spectrochemical plastic resin identification and subsequent sorting. Our results show that limited disassembly with whole-part identification can produce substantial yields in separated streams of recovered engineering thermoplastics. We find that disassembly with identification does not constitute a bottleneck, but rather, with relatively few workers, can be configured to pull the process and thus decrease maximum staging space requirements.

  14. Poisoning by carbon monoxide in the hydrogen exchange reaction between deuterium gas and water preadsorbed on a platinum--alumina catalyst

    International Nuclear Information System (INIS)

    Iida, I.; Tamaru, K.

    1979-01-01

    Poisoning by carbon monoxide in the exchange reaction between deuterium and the water preadsorbed on a platinum--alumina catalyst was studied, by measuring not only the rate of reaction but also its kinetic behavior and the adsorption of reactants on the catalyst surface. The shape of the poisoning curve is closely associated with the kinetic behavior and exhibited an abrupt change on freezing the adsorbed water below 273 0 K. When the rate is proportional to deuterium pressure and independent of the amount of water adsorbed, the exchange rate dropped sharply by carbon monoxide adsorbed of a few percent coverage without any marked changes in the amount and the rate of hydrogen adsorption on the platinum surface. However, at temperatures lower than 273 0 K and at higher deuterium pressures, the rate depends not on the deuterium pressure but on the amount of water adsorbed. The migration of hydrogen in or through the adsorbed water is seemingly sufficiently suppressed by freezing to control the overall reaction rate. In this case, a small amount of adsorption of carbon monoxide did not show any toxicity, but then a steep poisoning started accompanying a change in the kinetic behavior. It was accordingly demonstrated that the mechanism of the reaction may be better understood by studying poisoning and measuring adsorption, overall rate, and kinetic behavior

  15. Study on radiation degradation of hydroxylamine derivatives. Pt.3: Qualitative and quantitative analyses of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine

    International Nuclear Information System (INIS)

    Wang Jinhua; Bao Borong; Wu Minghong; Sun Xilian

    2004-01-01

    The qualitative and quantitative analysis of hydrogen and carbon monoxide produced by radiation degradation of N,N-diethyl hydroxylamine is performed on a 2 m column packed with 5 Angstrom molecular sieve and equipped with a thermal conductivity detector. The analysis of hydrogen employs argon as a carrier gas, the column temperature is 85 degree C and the detector temperature is 110 degree C; the analysis of carbon monoxide employs hydrogen as a carrier gas, the column temperature is 50 degree C and the detector temperature is 80 degree C. The results show that the volume fraction of hydrogen is increased with the increase of dose, but has little relationship with the concentration of N,N-diethyl hydroxylamine. Carbon monoxide is only produced when the absorption dose is very high and the volume fraction is very low

  16. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    Science.gov (United States)

    At some level, carboxyhemoglobin (RbCO) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in normal and ischemic heart patients. At high RbCO levels in normal subjects, brain function is also affected and behavioral performance is impaired. These are fin...

  17. Computation of diatomic molecular spectra for selected transitions of aluminum monoxide, cyanide, diatomic carbon, and titanium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Parigger, Christian G., E-mail: cparigge@tennessee.edu [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Woods, Alexander C.; Surmick, David M.; Gautam, Ghaneshwar; Witte, Michael J. [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Hornkohl, James O. [Hornkohl Consulting, Tullahoma, TN 37388 (United States)

    2015-05-01

    Laser ablation studies with laser-induced breakdown spectroscopy (LIBS) typically emphasize atomic species yet fingerprints from molecular species can occur subsequently or concurrently. In this work, selected molecular transitions of aluminum monixide (AlO), diatomic carbon (C{sub 2}), cyanide (CN), and titanium monoxide (TiO) are accurately computed. Line strength tables are used to describe the radiative transitions of diatomic molecules primarily in the visible, optical region. Details are elaborated of the computational procedure that allows one to utilize diatomic spectra as a predictive and as a diagnostic tool. In order to create a computed spectrum, the procedure requires information regarding the temperature of the diatomic transitions along with other input such as the spectral resolution. When combined with a fitting algorithm to optimize such parameters, this procedure is used to infer information from an experimentally obtained spectrum. Furthermore, the programs and data files are provided for LIBS investigations that also reveal AlO, C{sub 2}, CN, and TiO diatomic spectra. - Highlights: • We present a program for fitting of molecular spectra. • This includes data base for AlO, C{sub 2}, CN, and TiO. • We discuss the details of the program including fitting. • We show computed examples and reference current work.

  18. Merge of terminological resources

    DEFF Research Database (Denmark)

    Henriksen, Lina; Braasch, Anna

    2012-01-01

    In our globalized world, the amount of cross-national communication increases rapidly, which also calls for easy access to multi-lingual high quality terminological resources. Sharing of terminology resources is currently becoming common practice, and efficient strategies for integration...... – or merging – of terminology resources are strongly needed. This paper discusses prerequisites for successful merging with the focus on identification of candidate duplicates of a subject domain found in the resources to be merged, and it describes automatic merging strategies to be applied to such duplicates...... in electronic terminology resources. Further, some perspectives of manual, supplementary assessment methods supporting the automatic procedures are sketched. Our considerations are primarily based on experience gained in the IATE and EuroTermBank projects, as merging was a much discussed issue in both projects....

  19. 1H MR spectroscopy of gray and white matter in carbon monoxide poisoning

    DEFF Research Database (Denmark)

    Kondziella, D.; Danielsen, E.R.; Hansen, K.

    2009-01-01

    Carbon monoxide (CO) intoxication leads to acute and chronic neurological deficits, but little is known about the specific noxious mechanisms. (1)H magnetic resonance spectroscopy (MRS) may allow insight into the pathophysiology of CO poisoning by monitoring neurochemical disturbances, yet only......, magnetic resonance imaging (MRI) and neuropsychological testing. Five patients suffered from acute high-dose CO intoxication and were in coma for 1-6 days. In these patients, MRI revealed hyperintensities of the white matter and globus pallidus and also showed increased choline (Cho) and decreased N...

  20. Ion Back-Bombardment of GaAs Photocathodes Inside DC High Voltage Electron Guns

    CERN Document Server

    Grames, Joseph M; Brittian, Joshua; Charles, Daniel; Clark, Jim; Hansknecht, John; Lynn Stutzman, Marcy; Poelker, Matthew; Surles-Law, Kenneth E

    2005-01-01

    The primary limitation for sustained high quantum efficiency operation of GaAs photocathodes inside DC high voltage electron guns is ion back-bombardment of the photocathode. This process results from ionization of residual gas within the cathode/anode gap by the extracted electron beam, which is subsequently accelerated backwards to the photocathode. The damage mechanism is believed to be either destruction of the negative electron affinity condition at the surface of the photocathode or damage to the crystal structure by implantation of the bombarding ions. This work characterizes ion formation within the anode/cathode gap for gas species typical of UHV vacuum chambers (i.e., hydrogen, carbon monoxide and methane). Calculations and simulations are performed to determine the ion trajectories and stopping distance within the photocathode material. The results of the simulations are compared with test results obtained using a 100 keV DC high voltage GaAs photoemission gun and beamline at currents up to 10 mA D...

  1. Unintentional carbon monoxide poisoning hospitalization and emergency department counts and rates by county, year, and fire-relatedness among California residents,2000-2007

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of unintentional carbon monoxide poisoning (CO) inpatient hospitalizations and emergency...

  2. Complete electronics self-teaching guide with projects

    CERN Document Server

    Boysen, Earl

    2012-01-01

    An all-in-one resource on everything electronics-related! For almost 30 years, this book has been a classic text for electronics enthusiasts. Now completely updated for today's technology, this latest version combines concepts, self-tests, and hands-on projects to offer you a completely repackaged and revised resource. This unique self-teaching guide features easy-to-understand explanations that are presented in a user-friendly format to help you learn the essentials you need to work with electronic circuits. All you need is a general understanding of electronics concepts such as Oh

  3. Investigation of four carbon monoxide isotopomers in natural abundance by laser-induced fluorescence in a supersonic jet

    CSIR Research Space (South Africa)

    Du Plessis, A

    2007-01-01

    Full Text Available The four carbon monoxide (CO) isotopomers 12C16O, 13C16O, 12C18O and 12C17O have been detected simultaneously in a CO gas sample of natural isotopic abundance by measuring rovibronic excitation spectra of six vibronic bands in the Fourth Positive...

  4. Control of chemical reactions with electron beams; Kontrolle chemischer Reaktionen mit Elektronenstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Boehler, Esther

    2014-03-18

    Interaction between low-energy electrons and molecules can lead to dissociative electron attachment (DEA) or dissociative ionization (DI). In condensed matter, the resulting reactive fragments can attack adjacent molecules to yield larger products. In this thesis, reactions initiated by DEA to acetonitrile in condensed phase have been compared to the known gas phase fragmentation channels. Also, gas phase DEA experiments have been performed on chlorosilanes to study the effect of a variation of the organic ligands on the energy of their molecular orbitals and reactivity in DEA processes. Furthermore, hydroamination reactions induced by DI for different alkenes and amines have been investigated. A similar reaction of ammonia and carbon monoxide was shown to produce formamide (HCONH2), which is the smallest molecule to contain a peptide bond and thus represents an important building block of biologically relevant substances.

  5. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    Science.gov (United States)

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  6. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide 5 degree by 5 degree data

    Data.gov (United States)

    National Aeronautics and Space Administration — MAPS OverviewThe MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights on...

  7. Oscillator clustering in a resource distribution chain

    DEFF Research Database (Denmark)

    Postnov, D.; Sosnovtseva, Olga; Mosekilde, Erik

    2005-01-01

    separate the inherent dynamics of the individual oscillator from the properties of the coupling network. Illustrated by examples from microbiological population dynamics, renal physiology, and electronic oscillator theory, we show how competition for primary resources in a resource distribution chain leads...

  8. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    International Nuclear Information System (INIS)

    Mu, Jiali; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-01-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl 2 catalyst and PdCl 2 catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl 2 catalyst) was more thermally stable than PK (PdCl 2 catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by 1 H NMR, 13 C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E k ) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E k values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol −1 . Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK

  9. Thermal degradation kinetics of polyketone based on styrene and carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Jiali, E-mail: jiaqm411@163.com; Fan, Wenjun; Shan, Shaoyun; Su, Hongying; Wu, Shuisheng; Jia, Qingming

    2014-03-01

    Highlights: • The PK were synthesized from carbon monoxide and styrene in the presence of PANI-PdCl{sub 2} catalyst and PdCl{sub 2} catalyst. • The structures and thermal behaviors of PK prepared by homogenous and the supported catalyst were investigated. • The microstructures of PK were changed in the supported catalyst system. • The alternating PK copolymer (PANI-PdCl{sub 2} catalyst) was more thermally stable than PK (PdCl{sub 2} catalyst). • The degradation activation energy values were estimated by Flynn–Wall–Ozawa method and Kissinger method. - Abstract: Copolymerization of styrene with carbon monoxide to give polyketones (PK) was carried out under homogeneous palladium catalyst and polyaniline (PANI) supported palladium(II) catalyst, respectively. The copolymers were characterized by {sup 1}H NMR, {sup 13}C NMR and GPC. The results indicated that the PK catalyzed by the supported catalyst has narrow molecular weight distribution (PDI = 1.18). For comparison purpose of thermal behaviors of PK prepared by the homogeneous and the supported catalyst, thermogravimetric (TG) analysis and derivative thermogravimetric (DTG) were conducted at different heating rates. The peak temperatures (396–402 °C) for PK prepared by the supported catalyst are higher than those (387–395 °C) of PK prepared by the homogeneous catalyst. The degradation activation energy (E{sub k}) values were estimated by Flynn–Wall–Ozawa method and Kissinger method, respectively. The E{sub k} values, as determined by two methods, were found to be in the range 270.72 ± 0.03–297.55 ± 0.10 kJ mol{sup −1}. Structures analysis and thermal degradation analysis revealed that the supported catalyst changed the microstructures of PK, resulting in improving thermal stability of PK.

  10. Carbon monoxide measurements at Mace Head, Ireland

    Science.gov (United States)

    Doddridge, Bruce G.; Dickerson, Russell R.; Spain, T. Gerard; Oltmans, Samuel J.; Novelli, Paul C.

    1994-01-01

    The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

  11. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  12. Far-ultraviolet fluorescence of carbon monoxide in the red giant Arcturus

    International Nuclear Information System (INIS)

    Ayres, T.R.; Moos, H.W.; Linsky, J.L.

    1981-01-01

    We present evidence that many of the weak features observed with the International Ultraviolet Explorer (IUE) in the far-ultraviolet (1150--2000 A) spectrum of the archetype red giant Arcturus (K2 III) are A--X fourth positive bands of carbon monoxide excited by chromospheric emissions of O I, C I, and H I. The appearance of fluorescent CO bands near the wavelengths of commonly used indicators of high-temperature (T>2 x 10 4 K) plasma, such as C II lambda1335 and C IV lambda1548, introduces a serious ambiguity in diagnosing the presence of hot material in the outer atmospheres of the cool giants by means of low-dispersion IUE spectra

  13. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  14. Recent changes in carbon dioxide, carbon monoxide and methane and the implications for global climate change

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Conway, T.J.; Dlugokencky, E.J.; Tans, P.P. [National Oceanic and Atmospheric Administration, Boulder, CO (United States). Climate Monitoring and Diagnostics Lab.

    1995-01-01

    The article reviews figures for published data on recent changes of atmospheric levels of carbon dioxide, carbon monoxide and methane in terms of their sources and sinks. The largest source of CO{sub 2} is the combustion of fossil fuels, followed by emissions from deforestation and the oxidation of CO to CO{sub 2}. Carbon monoxide has an indirect influence on the earth`s radiative balance, as if levels of CO increase, levels of OH radicals decline which affects removal of other gases oxidised by this radical, notably CH{sub 4}. Major sources of CO are fossil fuel combustion, emissions from biomass, and oxidation of atmospheric CH{sub 4} and other non-methane hydrocarbons. The latest measurements suggest the depressed growth rates of CO{sub 2}, CO and CH{sub 4} have began to recover. Reasons for this are suggested. Future monitoring of atmospheric species in laboratories around the world, coupled with information on the isotopic signature of the trace gases, will improve our understanding of possible causes for trends in these gases. This will be invaluable in making policy decisions regarding future climate change. 34 refs., 4 figs.

  15. Retinal venous blood carbon monoxide response to bright light in male pigs: A preliminary study.

    Science.gov (United States)

    Oren, Dan A; Duda, Magdalena; Kozioł, Katarzyna; Romerowicz-Misielak, Maria; Koziorowska, Anna; Sołek, Przemysław; Nowak, Sławomir; Kulpa, Magdalena; Koziorowski, Marek

    2017-03-01

    The physical mechanism by which light is absorbed in the eye and has antidepressant and energizing effects in Seasonal Affective Disorder and other forms of psychiatric major depression is of scientific interest. This study was designed to explore one specific aspect of a proposed humoral phototransduction mechanism, namely that carbon monoxide (CO) levels increase in retinal venous blood in response to bright light. Eleven mature male pigs approximately six months of age were kept for 7days in darkness and fasted for 12h prior to surgery. Following mild sedation, anesthesia was induced. Silastic catheters were inserted into the dorsal nasal vein through the angular vein of the eye to reach the ophthalmic sinus, from which venous blood outflowing from the eye area was collected. The animals were exposed to 5000lx of fluorescent-generated white light. CO levels in the blood were analyzed by gas chromatography before and after 80min of light exposure. At baseline, mean CO levels in the retinal venous blood were 0.43±0.05(SE)nmol/ml. After bright light, mean CO levels increased to 0.54±0.06nmol/ml (two-tailed t-test plight exposure raises carbon monoxide levels in ophthalmic venous blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Adlayer structure dependent ultrafast desorption dynamics in carbon monoxide adsorbed on Pd (111)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung-Young; Camillone, Nina R.; Camillone, Nicholas, E-mail: nicholas@bnl.gov [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Xu, Pan [Department of Chemistry, Stony Brook University, Stony Brook, New York 11794 (United States); White, Michael G. [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Department of Chemistry, Stony Brook University, Stony Brook, New York 11794 (United States)

    2016-07-07

    We report our ultrafast photoinduced desorption investigation of the coverage dependence of substrate–adsorbate energy transfer in carbon monoxide adlayers on the (111) surface of palladium. As the CO coverage is increased, the adsorption site population shifts from all threefold hollows (up to 0.33 ML), to bridge and near bridge (>0.5 to 0.6 ML) and finally to mixed threefold hollow plus top site (at saturation at 0.75 ML). We show that between 0.24 and 0.75 ML this progression of binding site motifs is accompanied by two remarkable features in the ultrafast photoinduced desorption of the adsorbates: (i) the desorption probability increases roughly two orders magnitude, and (ii) the adsorbate–substrate energy transfer rate observed in two-pulse correlation experiments varies nonmonotonically, having a minimum at intermediate coverages. Simulations using a phenomenological model to describe the adsorbate–substrate energy transfer in terms of frictional coupling indicate that these features are consistent with an adsorption-site dependent electron-mediated energy coupling strength, η{sub el}, that decreases with binding site in the order: three-fold hollow > bridge and near bridge > top site. This weakening of η{sub el} largely counterbalances the decrease in the desorption activation energy that accompanies this progression of adsorption site motifs, moderating what would otherwise be a rise of several orders of magnitude in the desorption probability. Within this framework, the observed energy transfer rate enhancement at saturation coverage is due to interadsorbate energy transfer from the copopulation of molecules bound in three-fold hollows to their top-site neighbors.

  17. On the interactions between carbon monoxide and transition metals; Contribution a l'etude des interractions de l'oxyde de carbone et des metaux de transition

    Energy Technology Data Exchange (ETDEWEB)

    Degras, D E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-12-01

    The sticking of carbon monoxide on surface atoms of transition metals is a collective phenomenon: according to the adsorption process period which is considered, this phenomenon may be formally described either by the Elovich equation or essentially from a steric point of view. The process rate depends upon the nature of the metal, the carbon monoxide pressure the temperature and the population densities of the induced and fundamental energy levels of the gas-solid bond. At least one of these induced levels tends to disappear with increasing time. For a localised adsorption and taking into account the surface Rayleigh waves, the analysis of the surface entropy yields the so-called iso-kinetic temperature for thermal desorption. This temperature is correlated with the cohesive energy of the metal surface atoms. Finally, it is shown that the interactions of a low energy electron bean with adsorbed molecules - reflection and energy exchange, desorption, ionization or dissociative ionization are strongly dependent on the energy levels of the gas-solid bond and the relative populations of these levels. (author) [French] La capture des molecules d'oxyde de carbone par les atomes de surface des metaux de transition est un phenomene collectif: il peut etre decrit formellernent soit par l'equation d'Elovich, soit a partir de considerations purement steriques suivant la periode envisagee dans l'evolution du processus d'adsorption. Cette evolution est determinee par la nature du metal, la pression d'oxyde de carbone, la temperature et la densite des populations des niveaux fondamental et induits de la liaison. L'un au moins de ceux-ci tend a disparaitre avec le temps. L' etude de l'entropie du complexe de surface a partir des ondes de Rayleigh en adsorption localisee permet de retrouver theoriquernent la temperature dite isocinetique dans la dissociation thermique de ce complexe. Cette temperature depend de la cohesion des atomes rnetalliques de surface. Enfin l'interaction d

  18. [Etiology of combined inhalational hydrocyanic acid and carbon monoxide poisoning].

    Science.gov (United States)

    Sigrist, T; Dirnhofer, R

    1979-01-01

    A young man was found dead in a kitchen, that was partly burnt. Autopsy revealed, as cause of death, a combined intoxication following inhalation of carbon monoxide and hydrocyanic acid. Own investigations on the pyrolysis of pieces of furniture found in the kitchen (plastic plates containing melamine and plates containing formaldehyde) showed, that hydrocyanic acid was liberated through combustion of such substances and inhaled by the victim. The poisoning picture is discussed, and discussion includes especially considerations on the peculiar sensitivity of the brain toward the action of hydrocyanic acid and the relative insensitivity of the heart muscle. It is thought that the cause of such sensitivity difference lies in the physiological differences of the intracellular energy production. Finally the dangers of combustion gases developing from burning plastic materials are reemphasized.

  19. Fuelling regulation with Electronic fuel injection for small spark ignition engine using Fuzzy Logic

    International Nuclear Information System (INIS)

    Shah, S.R.; Sahir, M.H.

    2004-01-01

    The use of Electronic Control systems in automotive applications gives the design engineer greater control over various processes compared with mechanical methods Examples of such electronic control systems are Electronic Fuel Injection (EFI), Traction Control Systems (TCS) and Anti-lock Braking Systems (ABS). In addition, the development of inexpensive and fast microcontrollers has remarkably improve, performance of passive and active safety systems of automobiles, without causing excessive increase in prices of vehicles -a favourable factor from the consumer's perspective. This paper deals with a possible electronic aid for the improvement of power control in a motorcycle. Controlling the speed and power of a motorcycle is difficult; especially on bumpy and uneven terrain. In this paper, the development of an EPI system is discussed, incorporating artificial intelligence to regulate the fuel supplied to the engine. It would minimize wheel slippage and jerky and sudden acceleration which potentially dangerous. It would also reduce production of large quantities of pollutant like hydrocarbons and carbon monoxide. Fuel consumption would also improve during stop-and-go traffic. (author)

  20. Review: hemodynamic response to carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Penney, D.G.

    1988-04-01

    Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. Augmented cardiac output usually observed with moderate COHb may be compromised in more sever poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.

  1. Kinetics of Carbon Monoxide Electro-Oxidation in Solid-Oxide Fuel Cells from Ni-YSZ Patterned-Anode Measurements

    KAUST Repository

    Hanna, J.; Lee, W. Y.; Ghoniem, A. F.

    2013-01-01

    A mathematical model is developed around the framework of a reduced mechanism describing electrochemical oxidation of carbon monoxide on Ni-YSZ patterned anodes. The electro-oxidation mechanism involves three reactions, one describing adsorption/ desorption of COonNi, and two single-electron charge-transfer steps inwhich the surface adsorbate CO(Ni) participates directly. These steps are coupled with surface transport in a reaction-diffusion model for which analytic equilibrium and steady-state solutions are derived. As much as possible, we make use of existing, independent, published information about heterogeneous chemistry, surface transport, and other model parameters. The only unknowns in our model are taken to be the kinetic rate constants of the electrochemical reactions, which we evaluate by fitting the model predictions to previously published patterned-anode experiments [B. Habibzadeh, Ph.D. Thesis, University of Maryland, College Park, MD, USA (2007)]. The results show that diffusion of CO on the Ni surface to the three-phase boundary is the rate-controlling process for CO electro-oxidation. Moreover, from a reaction standpoint, the charge-transfer process is dominated by a slow step involving CO(Ni). These findings collectively demonstrate the critical dependence of the electro-oxidation process to the direct participation of CO. © 2013 The Electrochemical Society. All rights reserved.

  2. Kinetics of Carbon Monoxide Electro-Oxidation in Solid-Oxide Fuel Cells from Ni-YSZ Patterned-Anode Measurements

    KAUST Repository

    Hanna, J.

    2013-04-17

    A mathematical model is developed around the framework of a reduced mechanism describing electrochemical oxidation of carbon monoxide on Ni-YSZ patterned anodes. The electro-oxidation mechanism involves three reactions, one describing adsorption/ desorption of COonNi, and two single-electron charge-transfer steps inwhich the surface adsorbate CO(Ni) participates directly. These steps are coupled with surface transport in a reaction-diffusion model for which analytic equilibrium and steady-state solutions are derived. As much as possible, we make use of existing, independent, published information about heterogeneous chemistry, surface transport, and other model parameters. The only unknowns in our model are taken to be the kinetic rate constants of the electrochemical reactions, which we evaluate by fitting the model predictions to previously published patterned-anode experiments [B. Habibzadeh, Ph.D. Thesis, University of Maryland, College Park, MD, USA (2007)]. The results show that diffusion of CO on the Ni surface to the three-phase boundary is the rate-controlling process for CO electro-oxidation. Moreover, from a reaction standpoint, the charge-transfer process is dominated by a slow step involving CO(Ni). These findings collectively demonstrate the critical dependence of the electro-oxidation process to the direct participation of CO. © 2013 The Electrochemical Society. All rights reserved.

  3. The effect of modified atmosphere packaging with carbon monoxide on the storage quality of master-packaged fresh pork

    NARCIS (Netherlands)

    Wilkinson, B.H.P.; Janz, J.A.M.; Morel, P.C.H.; Purchas, R.W.; Hendriks, W.H.

    2006-01-01

    Modified atmosphere packaging with carbon dioxide is effective for prolonging shelf-life of fresh meat. Addition of carbon monoxide to the system provides the advantage of enhancing meat colour. The study objective was to determine the effect of CO2-MAP + 0.4% CO, vs. 100% CO2-MAP, on the

  4. Multiple Victims of Carbon Monoxide Poisoning in the Aftermath of a Wildfire: A Case Series

    Directory of Open Access Journals (Sweden)

    Luís Ramos dos Santos

    2018-03-01

    Conclusion: Use of hyperbaric oxygen appears to have reduced the incidence of the syndrome. This seems to be the first Portuguese series reporting use of hyperbaric oxygen in carbon monoxide poisoning due to wildfires. The authors intend to alert to the importance of referral of these patients because the indications and benefits of this treatment are well documented. This is especially important given the ever-growing issue of wildfires in Portugal.

  5. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases

    Directory of Open Access Journals (Sweden)

    A. Mishra

    2011-05-01

    Full Text Available In this review, recent works on the preferential oxidation of carbon monoxide in hydrogen rich gases for fuel cell applications are summarized. H2 is used as a fuel for polymer-electrolyte membrane fuel cell (PEMFC. It is produced by reforming of natural gas or liquid fuels followed by water gas shift reaction. The produced gas consists of H2, CO, and CO2. In which CO content is around 1%, which is highly poisonous for the Pt anode of the PEMFC so that further removal of CO is needed. Catalytic preferential oxidation of CO (CO-PROX is one of the most suitable methods of purification of H2 because of high CO conversion rate at low temperature range, which is preferable for PEMFC operating conditions. Catalysts used for COPROX are mainly noble metal based; gold based and base metal oxide catalysts among them Copper-Ceria based catalysts are the most appropriate due to its low cost, easy availability and result obtained by these catalysts are comparable with the conventional noble metal catalysts. Copyright © 2011 BCREC UNDIP. All rights reserved(Received: 22nd October 2010, Revised: 12nd January 2011, Accepted: 19th January 2011[How to Cite: A. Mishra, R. Prasad. (2011. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases. Bulletin of Chemical Reaction Engineering & Catalysis, 6 (1: 1-14. doi:10.9767/bcrec.6.1.191.1-14][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.1.191.1-14 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/191] | View in 

  6. Carbon Monoxide Distribution over Peninsular Malaysia from the Atmospheric Infrared Sounder (AIRS)

    Science.gov (United States)

    Rajab, Jaso M.; MatJafri, M. Z.; Lim, H. S.; Abdullah, K.

    2009-07-01

    The Atmospheric Infrared Sounder (AIRS) onboard NASA's Aqua satellite. It daily coverage of ˜70% of the planet represents a significant evolutionary advance in satellite traces gas remote sensing. AIRS, the part of a large international investment to upgrade the operational meteorological satellite systems, is first of the new generation of meteorological advanced sounders for operational and research use, Providing New Insights into Weather and Climate for the 21st Century. Carbon monoxide (CO) is a ubiquitous, an indoor and outdoor air pollutant, is not a significant greenhouse gas as it absorbs little infrared radiation from the Earth. However, it does have an influence on oxidization in the atmosphere through interaction with hydroxyl radicals (OH), which also react with methane, halocarbons and tropospheric ozone. It produced by the incomplete combustion of fossil fuels and biomass burning, and that it has a role as a smog. The aim of this investigation is to study the (CO) carbon monoxide distribution over Peninsular Malaysia. The land use map of the Peninsular Malaysia was conducted by using CO total column amount, obtained from AIRS data, the map & data was processed and analyzed by using Photoshop & SigmaPlot 11.0 programs and compared for timing of various (day time) (28 August 2005 & 29 August 2007) for both direct comparison and the comparison using the same a priori profile, the CO concentrations in 28/8/2005 higher. The CO maps were generated using Kriging Interpolation technique. This interpolation technique produced high correlation coefficient, R2 and low root mean square error, RMS for CO. This study provided useful information for influence change of CO concentration on varies temperature.

  7. Deteriorations of pulmonary function, elevated carbon monoxide levels and increased oxidative stress amongst water-pipe smokers

    Directory of Open Access Journals (Sweden)

    Funda Karaduman Yalcin

    2017-10-01

    Full Text Available Objectives: A water pipe (hookah is a tobacco smoking tool which is thought to be more harmless than a cigarette, and there are no adequate studies about its hazards to health. Water-pipe smoking is threatening health of the youth in the world today. The objective of this study has been to investigate the carbon monoxide (CO levels in breath, examine the changes in pulmonary function tests (PFT and to assess the change of the oxidative stress parameters in blood after smoking a water pipe. Material and Methods: This study is a cross-sectional analytical study that has included 50 volunteers who smoke a water pipe and the control group of 50 volunteers who smoke neither a cigarette nor a water pipe. Carbon monoxide levels were measured in the breath and pulmonary function tests (PFTs were performed before and after smoking a water pipe. Blood samples were taken from either the volunteer control group or water-pipe smokers group after smoking a water pipe for the purpose of evaluation of the parameters of oxidative stress. Results: Carbon monoxide values were measured to be 8.08±7.4 ppm and 28.08±16.5 ppm before and after smoking a water pipe, respectively. This increment was found statistically significant. There were also significant reductions in PFTs after smoking a water pipe. Total oxidative status (TOS, total antioxidant status (TAS and oxidative stress index (OSI were found prominently higher after smoking a water pipe for the group of water-pipe smokers than for the control group. Conclusions: This study has shown that water-pipe smoking leads to deterioration in pulmonary function and increases oxidative stress. To the best of our knowledge this study is the only one that has shown the effect of water-pipe smoking on oxidative stress. More studies must be planned to show the side effects of water-pipe habit and protective policies should be planned especially for young people in Europe. Int J Occup Med Environ Health 2017;30(5:731

  8. Structure and electronic properties of AlCrO{sub x}N{sub 1−x} thin films deposited by reactive magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Najafi, H.; Karimi, A. [Institute of Condensed Matter Physics (ICMP), Swiss Federal Institute of Technology Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Oveisi, E. [Electron Spectrometry and Microscopy Laboratory (LSME-ICMP), Swiss Federal Institute of Technology in Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Morstein, M. [PLATIT AG, Advanced Coating Systems, CH-2545 Selzach (Switzerland)

    2014-12-01

    In this study, the main attempt is devoted to investigating the microstructure and electronic properties of AlCrO{sub x}N{sub 1−x} films in a wide range of oxygen concentrations from 0 to 1. These oxynitride films were deposited by pulsed DC magnetron sputtering from Al{sub 55}Cr{sub 45} targets. Our results showed that films with x = O/(O + N) < 0.6, exhibit a cubic (B1) lattice with a well-developed columnar structure. The incorporation of oxygen into the films without any oxide segregation results in the formation of a substitutional AlCrO{sub x}N{sub 1−x} solid solution and material system behaves like nitrides electronically. In the range of oxygen contents from 0.6 ≤ O/(O + N) < 0.97, coatings with fine columns, diffuse boundaries and high values of metal vacancies were formed. However, the B1 lattice survived despite the large proportion of oxygen. According to the structural and electronic properties of the corresponding layers, we assign this region to the formation of an amorphous phase and metastable monoxides with a B1 structure. Coatings with O/(O + N) ≥ 0.97 are electronically assigned to a solid solution of α-(Al,Cr){sub 2}(O{sub 0.97},N{sub 0.03}){sub 3} with corundum lattice and finer columnar structure. - Highlights: • AlCr(O{sub x}N{sub 1−x}) layers with variable oxygen content 0 < x < 1 were grown. • The layers with the lowest oxygen content, x < 0.6, electronically behave like nitrides. • Coatings with 0.6 ≤ x < 0.97 are assigned to metastable monoxides. • The oxide region consisted of a solid solution of α-phase with a corundum structure.

  9. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    Science.gov (United States)

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  10. The immunomodulatory role of carbon monoxide during transplantation

    Directory of Open Access Journals (Sweden)

    Amano Mariane

    2013-01-01

    Full Text Available Abstract The number of organ and tissue transplants has increased worldwide in recent decades. However, graft rejection, infections due to the use of immunosuppressive drugs and a shortage of graft donors remain major concerns. Carbon monoxide (CO had long been regarded solely as a poisonous gas. Ultimately, physiological studies unveiled the endogenous production of CO, particularly by the heme oxygenase (HO-1 enzyme, recognizing CO as a beneficial gas when used at therapeutic doses. The protective properties of CO led researchers to develop uses for it, resulting in devices and molecules that can deliver CO in vitro and in vivo. The resulting interest in clinical investigations was immediate. Studies regarding the CO/HO-1 modulation of immune responses and their effects on various immune disorders gave rise to transplantation research, where CO was shown to be essential in the protection against organ rejection in animal models. This review provides a perspective of how CO modulates the immune system to improve transplantation and suggests its use as a therapy in the field.

  11. Brain CT scan in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    We, En-Huei

    1986-01-01

    The brain CT findings in 19 patients with acute carbon monoxide poisoning was analysed and the emphasis was placed on the relationship between CT findings and prognosis. Five had a normal manifestation in CT ; eight had the findings of ovoid or patchy low density area in globus pallidus, bilateral or unlateral, during the second day to fifth week after poisoning, and the low density areas were decreasing and blurring in edge in follow up and at last disappeared during 3 - 14 weeks in three cases of them ; nine showed the appearance of diffuse low density of white matter and of globus pallidus in some of them ; two had an appearance of brain atrophy. The pathology of CT findings mentioned above may be brain edema, necrosis, malacia and degeneration in gray matter and globus pallidus. The result suggested the cases with normal CT manifestation, cerebral edema and decreasing and disappearing low density area had a good prognosis, in contrary, the cases with persistant low density in globus pallidus had a poorer prognosis. (author)

  12. General circulation model study of atmospheric carbon monoxide

    International Nuclear Information System (INIS)

    Pinto, J.P.; Yung, Y.L.; Rind, D.; Russell, G.L.; Lerner, J.A.; Hansen, J.E.; Hameed, S.

    1983-01-01

    The carbon monoxide cycle is studied by incorporating the known and hypothetical sources and sinks in a tracer model that uses the winds generated by a general circulation model. Photochemical production and loss terms, which depend on OH radical concentrations, are calculated in an interactive fashion. The computed global distribution and seasonal variations of CO are compared with observations to obtain constraints on the distribution and magnitude of the sources and sinks of CO, and on the tropospheric abundance of OH. The simplest model that accounts for available observations requires a low latitude plant source of about 1.3 x 10 15 g yr -1 , in addition to sources from incomplete combustion of fossil fuels and oxidation of methane. The globally averaged OH concentration calculated in the model is 7 x 10 5 cm -3 . Models that calculate globally averaged OH concentrations much lower than our nominal value are not consistent with the observed variability of CO. Such models are also inconsistent with measurements of CO isotopic abundances, which imply the existence of plant sources

  13. Nitric oxide and carbon monoxide diffusing capacity after a 1-h oxygen dive to 9 m of sea water

    NARCIS (Netherlands)

    van Ooij, P. J. A. M.; van Hulst, R. A.; Houtkooper, A.; Sterk, P. J.

    2014-01-01

    To prevent extensive pulmonary lesions in submerged oxygen divers lung function like the forced vital capacity (FVC) or the diffusing capacity for carbon monoxide (DL,co) are used to monitor pulmonary oxygen toxicity (POT). As the diffusing capacity for nitric oxide (DL,no) measures more accurately

  14. Highly n-Type Titanium Oxide as an Electronically Active Support for Platinum in the Catalytic Oxidation of Carbon Monoxide

    KAUST Repository

    Baker, L. Robert; Hervier, Antoine; Seo, Hyungtak; Kennedy, Griffin; Komvopoulos, Kyriakos; Somorjai, Gabor A.

    2011-01-01

    -support interaction is electronic activation of surface adsorbates by charge carriers. Motivated by the goal of using electronic activation to drive nonthermal chemistry, we investigated the ability of the oxide support to mediate charge transfer. We report

  15. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Pool Safely Business & Manufacturing Business & Manufacturing Business Education Small Business Resources Testing & Certification Import Surveillance International Recall Guidance ...

  16. Electronic conferencing for continuing medical education: a resource survey.

    Science.gov (United States)

    Sternberg, R J

    1986-10-01

    The use of electronic technologies to link participants for education conferences is an option for providers of Continuing Medical Education. In order to profile the kinds of electronic networks currently offering audio- or videoteleconferences for physician audiences, a survey was done during late 1985. The information collected included range of services, fees, and geographic areas served. The results show a broad diversity of providers providing both interactive and didactic programming to both physicians and other health care professionals.

  17. Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production

    Directory of Open Access Journals (Sweden)

    Perez Roberto SGM

    2005-06-01

    Full Text Available Abstract Background Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all. The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime. Methods A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams was used in this system. A low flow anesthesia (500 ml/min was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container. Results Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively. It was lower with isoflurane (2512 ppm. We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions. Conclusion All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.

  18. Interaction of low energy electrons with surface lattice vibrations. Final report

    International Nuclear Information System (INIS)

    Tong, S.Y.

    1984-01-01

    In carrying out the DOE contract, we have succeeded in constructing a new microscopic theory, with multiple scattering, for the inelastic scattering of electrons by surface vibrations. We have applied the theory to detailed studies of angle and energy variations of the inelastic cross-section for two important systems in surface physics: carbon monoxide molecules adsorbed on the (100) surface of a nickel crystal, and hydrogen atoms adsorbed on a reconstructed tungsten (100) surface. These calculations have outlined general trends that we expect to apply to a wide variety of systems. Also, we have discovered a series of new selection rules that apply to off-specular scattering. Particularly interesting are pseudo-selection rules which are not group theoretical in origin, but approximate statements that hold well when the electron scattering amplitude exhibits a slow energy variation. We have found and defined conditions for which these selection rules would hold and break down

  19. The effect of carbon monoxide on planetary haze formation

    Energy Technology Data Exchange (ETDEWEB)

    Hörst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  20. Bio-Inspired Carbon Monoxide Sensors with Voltage-Activated Sensitivity

    KAUST Repository

    Savagatrup, Suchol

    2017-09-27

    Carbon monoxide (CO) outcompetes oxygen when binding to the iron center of hemeproteins, leading to a reduction in blood oxygen level and acute poisoning. Harvesting the strong specific interaction between CO and the iron porphyrin provides a highly selective and customizable sensor. We report the development of chemiresistive sensors with voltage-activated sensitivity for the detection of CO comprising iron porphyrin and functionalized single-walled carbon nanotubes (F-SWCNTs). Modulation of the gate voltage offers a predicted extra dimension for sensing. Specifically, the sensors show a significant increase in sensitivity toward CO when negative gate voltage is applied. The dosimetric sensors are selective to ppm levels of CO and functional in air. UV/Vis spectroscopy, differential pulse voltammetry, and density functional theory reveal that the in situ reduction of FeIII to FeII enhances the interaction between the F-SWCNTs and CO. Our results illustrate a new mode of sensors wherein redox active recognition units are voltage-activated to give enhanced and highly specific responses.