  1. Angular vibrations of cryogenically cooled double-crystal monochromators.

    Science.gov (United States)

    Sergueev, I; Döhrmann, R; Horbach, J; Heuer, J

    2016-09-01

    The effect of angular vibrations of the crystals in cryogenically cooled monochromators on the beam performance has been studied theoretically and experimentally. A simple relation between amplitude of the vibrations and size of the focused beam is developed. It is shown that the double-crystal monochromator vibrations affect not only the image size but also the image position along the optical axis. Several methods to measure vibrations with the X-ray beam are explained and analyzed. The methods have been applied to systematically study angular crystal vibrations at monochromators installed at the PETRA III light source. Characteristic values of the amplitudes of angular vibrations for different monochromators are presented.

  2. Thermal and structural finite element analysis of water cooled silicon monochromator for synchrotron radiation comparison of two different cooling schemes

    CERN Document Server

    Artemiev, A I; Busetto, E; Hrdy, J; Mrazek, D; Plesek, I; Savoia, A

    2001-01-01

    The article describes the results of Finite Element Analysis (FEA) of the first Si monochromator crystal distortions due to Synchrotron Radiation (SR) heat load and consequent analysis of the influence of the distortions on a double crystal monochromator performance. Efficiencies of two different cooling schemes are compared. A thin plate of Si crystal is lying on copper cooling support in both cases. There are microchannels inside the cooling support. In the first model the direction of the microchannels is parallel to the diffraction plane. In the second model the direction of the microchannels is perpendicular to the diffraction plane or in other words, it is a conventional cooling scheme. It is shown that the temperature field along the crystal volume is more uniform and more symmetrical in the first model than in the second (conventional) one.

  3. A high-precision cryogenically-cooled crystal monochromator for the APS diagnostics beamline

    Energy Technology Data Exchange (ETDEWEB)

    Rotela, E.; Yang, B.; Sharma, s.; Barcikowski, A.

    2000-07-24

    A high-precision cryogenically-cooled crystal monochromator has been developed for the APS diagnostics beamline. The design permits simultaneous measurements of the particle beam size and divergence. It provides for a large rotation angle, {minus}15{degree} to 180{degree}, with a resolution of 0.0005{degree}. The roll angle of the crystal can be adjusted by up to {+-}3{degree} with a resolution of 0.0001{degree}. A vertical translational stage, with a stroke of {+-}25 mm and resolution of 8 {micro}m, is provided to enable using different parts of the same crystal or to retract the crystal from the beam path. The modular design will allow optimization of cooling schemes to minimize thermal distortions of the crystal under high heat loads.

  4. A water-cooled x-ray monochromator for using off-axis undulator beam.

    Energy Technology Data Exchange (ETDEWEB)

    Khounsary, A.; Maser, J.

    2000-12-11

    Undulator beamlines at third-generation synchrotrons x-ray sources are designed to use the high-brilliance radiation that is contained in the central cone of the generated x-ray beams. The rest of the x-ray beam is often unused. Moreover, in some cases, such as in the zone-plate-based microfocusing beamlines, only a small part of the central radiation cone around the optical axis is used. In this paper, a side-station branch line at the Advanced Photon Source that takes advantage of some of the unused off-axis photons in a microfocusing x-ray beamline is described. Detailed information on the design and analysis of a high-heat-load water-cooled monochromator developed for this beamline is provided.

  5. The performance of a cryogenically cooled monochromator for an in-vacuum undulator beamline.

    Science.gov (United States)

    Zhang, Lin; Lee, Wah Keat; Wulff, Michael; Eybert, Laurent

    2003-07-01

    The channel-cut silicon monochromator on beamline ID09 at the European Synchrotron Radiation Facility is indirectly cooled from the sides by liquid nitrogen. The thermal slope error of the diffracting surface is calculated by finite-element analysis and the results are compared with experiments. The slope error is studied as a function of cooling coefficients, beam size, position of the footprint and power distribution. It is found that the slope error versus power curve can be divided into three regions: (i). The linear region: the thermal slope error is linearly proportional to the power. (ii). The transition region: the temperature of the Si crystal is close to 125 K; the thermal slope error is below the straight line extrapolated from the linear curve described above. (iii). The non-linear region: the temperature of the Si crystal is higher than 125 K and the thermal slope error increases much faster than the power. Heat-load tests were also performed and the measured rocking-curve widths are compared with those calculated by finite-element modeling. When the broadening from the intrinsic rocking-curve width and mounting strain are included, the calculated rocking-curve width versus heat load is in excellent agreement with experiment.

  6. International Ventilation Cooling Application Database

    DEFF Research Database (Denmark)

    Holzer, Peter; Psomas, Theofanis Ch.; OSullivan, Paul

    2016-01-01

    The currently running International Energy Agency, Energy and Conservation in Buildings, Annex 62 Ventilative Cooling (VC) project, is coordinating research towards extended use of VC. Within this Annex 62 the joint research activity of International VC Application Database has been carried out, ...

  7. Cryogenically cooled bent double-Laue monochromator for high-energy undulator X-rays (50-200 keV).

    Science.gov (United States)

    Shastri, S D; Fezzaa, K; Mashayekhi, A; Lee, W K; Fernandez, P B; Lee, P L

    2002-09-01

    A liquid-nitrogen-cooled monochromator for high-energy X-rays consisting of two bent Si(111) Laue crystals adjusted to sequential Rowland conditions has been in operation for over two years at the SRI-CAT sector 1 undulator beamline of the Advanced Photon Source (APS). It delivers over ten times more flux than a flat-crystal monochromator does at high energies, without any increase in energy width (DeltaE/E approximately 10(-3)). Cryogenic cooling permits optimal flux, avoiding a sacrifice from the often employed alternative technique of filtration - a technique less effective at sources like the 7 GeV APS, where considerable heat loads can be deposited by high-energy photons, especially at closed undulator gaps. The fixed-offset geometry provides a fully tunable in-line monochromatic beam. In addition to presenting the optics performance, unique crystal design and stable bending mechanism for a cryogenically cooled crystal under high heat load, the bending radii adjustment procedures are described.

  8. International Ventilation Cooling Application Database

    DEFF Research Database (Denmark)

    Holzer, Peter; Psomas, Theofanis Ch.; OSullivan, Paul

    2016-01-01

    The currently running International Energy Agency, Energy and Conservation in Buildings, Annex 62 Ventilative Cooling (VC) project, is coordinating research towards extended use of VC. Within this Annex 62 the joint research activity of International VC Application Database has been carried out...... European and international Low Energy buildings. Still it’s not really widespread. Obstacles are challenges as regards noise, dust, weather and burglary, proving the research efforts of the Annex being necessary. The VC database forms a worthwhile basis for both dissemination and further research targets......., systematically investigating the distribution of technologies and strategies within VC. The database is structured as both a ticking-list-like building-spreadsheet and a collection of building-datasheets. The content of both closely follows Annex 62 State-Of-The- Art-Report. The database has been filled, based...

  9. Mirror monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Mankos, Marian [Electron Optica, Inc., Palo Alto, CA (United States); Shadman, Khashayar [Electron Optica, Inc., Palo Alto, CA (United States)

    2014-12-02

    In this SBIR project, Electron Optica, Inc. (EOI) is developing a mirror electron monochromator (MirrorChrom) attachment to new and retrofitted electron microscopes (EMs) for improving the energy resolution of the EM from the characteristic range of 0.2-0.5 eV to the range of 10-50 meV. This improvement will enhance the characterization of materials by imaging and spectroscopy. In particular, the monochromator will refine the energy spectra characterizing materials, as obtained from transmission EMs [TEMs] fitted with electron spectrometers, and it will increase the spatial resolution of the images of materials taken with scanning EMs (SEMs) operated at low voltages. EOI’s MirrorChrom technology utilizes a magnetic prism to simultaneously deflect the electron beam off the axis of the microscope column by 90° and disperse the electrons in proportional to their energies into a module with an electron mirror and a knife-edge. The knife-edge cuts off the tails of the energy distribution to reduce the energy spread of the electrons that are reflected, and subsequently deflected, back into the microscope column. The knife-edge is less prone to contamination, and thereby charging, than the conventional slits used in existing monochromators, which improves the reliability and stability of the module. The overall design of the MirrorChrom exploits the symmetry inherent in reversing the electron trajectory in order to maintain the beam brightness – a parameter that impacts how well the electron beam can be focused downstream onto a sample. During phase I, EOI drafted a set of candidate monochromator architectures and evaluated the trade-offs between energy resolution and beam current to achieve the optimum design for three particular applications with market potential: increasing the spatial resolution of low voltage SEMs, increasing the energy resolution of low voltage TEMs (beam energy of 5-20 keV), and increasing the energy resolution of conventional TEMs (beam

  10. APS high heat load monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach.

  11. for an Internal Cooling Air System

    Directory of Open Access Journals (Sweden)

    Tadaharu Kishibe

    2000-01-01

    Full Text Available The swirling flow field in an internal cooling air system in which the fluid passes through an inducer, a hollow turbine shaft, and a cavity between two disks (referred to as a wheel space is solved using computational fluid dynamics and the pressure fluctuations on the hollow shaft wall surface are measured.

  12. HIRDLS monochromator calibration equipment

    Science.gov (United States)

    Hepplewhite, Christopher L.; Barnett, John J.; Djotni, Karim; Whitney, John G.; Bracken, Justain N.; Wolfenden, Roger; Row, Frederick; Palmer, Christopher W. P.; Watkins, Robert E. J.; Knight, Rodney J.; Gray, Peter F.; Hammond, Geoffory

    2003-11-01

    A specially designed and built monochromator was developed for the spectral calibration of the HIRDLS instrument. The High Resolution Dynamics Limb Sounder (HIRDLS) is a precision infra-red remote sensing instrument with very tight requirements on the knowledge of the response to received radiation. A high performance, vacuum compatible monochromator, was developed with a wavelength range from 4 to 20 microns to encompass that of the HIRDLS instrument. The monochromator is integrated into a collimating system which is shared with a set of tiny broad band sources used for independent spatial response measurements (reported elsewhere). This paper describes the design and implementation of the monochromator and the performance obtained during the period of calibration of the HIRDLS instrument at Oxford University in 2002.

  13. Large monochromator systems at PETRA III

    Energy Technology Data Exchange (ETDEWEB)

    Horbach, J., E-mail: Jan.Horbach@desy.de [Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany); Degenhardt, M.; Hahn, U.; Heuer, J.; Peters, H.B.; Schulte-Schrepping, H. [Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany); Donat, A.; Luedecke, H. [Deutsches Elektronen-Synchrotron Zeuthen, Platanenallee 6, 15738 Zeuthen (Germany)

    2011-09-01

    For the beamlines of the new synchrotron radiation source PETRA III, fixed exit double crystal monochromators with specific features were developed. To achieve a compact arrangement of the canted undulator beamlines at Sectors 2 and 6, it is necessary to shift one of the two beamlines in vertical direction. This is done by Large Offset Monochromators (LOM). One of these monochromators (LOM500, installed at beamline P03) is cooled with liquid nitrogen as it accepts the white beam. LOM1250 (installed at beamline P08) accepts a monochromatic beam and therefore needs no cooling system. The challenge with this monochromator is its large beam offset by 1.25 m. The energy range in combination with this large vertical beam offset demands for a relative crystal movement of roughly 3 m along the beam direction. This is solved by translating each crystal by up to 1.5 m. LOM1250 is equipped with a laser-based stabilisation, which allows compensating the thermal drift of the mechanical components involved in the positioning of the crystals. This is done by piezo actors below the crystals using the laser beam position after passing each crystal as feedback. With this approach we provide a closed loop system without attenuation of the X-ray beam by position monitors. The third monochromator at beamline P06 shifts the beam only by 21 mm upwards but has a linear travel of one crystal by 3.9 m. This is due to its large energy range of 4.4-90 keV using multilayer crystals. The technical design and mechanical engineering issues of the three Large Monochromator Systems at beamlines P03, P06 and P08 are highlighted in this article.

  14. High-heat-load monochromator options for the RIXS beamline at the APS with the MBA lattice

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zunping, E-mail: zpliu@anl.gov; Gog, Thomas, E-mail: gog@aps.anl.gov; Stoupin, Stanislav A.; Upton, Mary H.; Ding, Yang; Kim, Jung-Ho; Casa, Diego M.; Said, Ayman H.; Carter, Jason A.; Navrotski, Gary [Advanced Photon Source, Argonne National Laboratory, 9700 S. Cass Ave, Lemont, IL 60439 (United States)

    2016-07-27

    With the MBA lattice for APS-Upgrade, tuning curves of 2.6 cm period undulators meet the source requirements for the RIXS beamline. The high-heat-load monochromator (HHLM) is the first optical white beam component. There are four options for the HHLM such as diamond monochromators with refrigerant of either water or liquid nitrogen (LN{sub 2}), and silicon monochromators of either direct or indirect cooling system. Their performances are evaluated at energy 11.215 keV (Ir L-III edge). The cryo-cooled diamond monochromator has similar performance as the water-cooled diamond monochromator because GaIn of the Cu-GaIn-diamond interface becomes solid. The cryo-cooled silicon monochromators perform better, not only in terms of surface slope error due to thermal deformation, but also in terms of thermal capacity.

  15. International Energy Agency Solar Heating and Cooling Program

    Science.gov (United States)

    Brooks, A. J.

    This trip was undertaken to participate in and represent the United States Industry at the International Energy Agency (IEA) Solar Heating and Cooling Program (SHCP) Task 14 Workshop. The meeting took place at the A1 Bani Hotel in Rome Italy.

  16. Bent Crystal Monochromator with Constant Crystal Center Position and 2-theta Arm for a Dispersive Beamline

    Science.gov (United States)

    Neuenschwander, Regis T.; Tolentino, Hélio C. N.

    2004-05-01

    For the new LNLS dispersive beam line it was designed a single-crystal monochromator and a 2-theta arm. The monochromator uses a new bender design assembled on the top of an in-vacuum HUBER goniometer. This bender is able to apply independent torque on each extremity of the crystal in a way that changes in the curvature radius do not affect the position of the center of the crystal. It also has a twist mechanism, based on eccentric bearings and elastic components. The crystal extremities are clamped to the bender using two water-cooled copper blocks, for thermal stabilization. All the bender's movements are done with vacuum compatible stepping-motors. The vacuum chamber was built with enough space to allow future installation of another bender for crystals with different Bragg planes. The internal mechanics is isolated from the vacuum chamber and can move up and down with three high precision jacks. The design of the 2-theta arm is based on two linear translation stages and some special bearings. The two stages are equipped with linear encoders, ball screws end linear bearings. With a proper alignment procedure, it is possible to find the equations that controls each translation stage in order to get a virtual rotation referenced to the monochromator center. The main arm is composed of a steel frame, a 3m long granite block, a central aluminum optical rail and two auxiliary side rails.

  17. Phase space density as a measure of cooling performance for the international muon ionization cooling experiment

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    The International Muon Ionization Cooling Experiment (MICE) is an experiment to demonstrate ionization cooling of a muon beam in a beamline that shares characteristics with one that might be used for a muon collider or neutrino factory. I describe a way to quantify cooling performance by examining the phase space density of muons, and determining how much that density increases. This contrasts with the more common methods that rely on the covariance matrix and compute emittances from that. I discuss why a direct measure of phase space density might be preferable to a covariance matrix method. I apply this technique to an early proposal for the MICE final step beamline. I discuss how matching impacts the measured performance.

  18. Keeping your cool: possible mechanisms for enhanced exercise performance in the heat with internal cooling methods.

    Science.gov (United States)

    Siegel, Rodney; Laursen, Paul B

    2012-02-01

    Exercising in hot environments results in a rise in core body temperature; an effect associated with impaired performance over a variety of exercise modes and durations. Precooling has become a popular strategy to combat this impairment, as evidence has shown it to be an effective method for lowering pre-exercise core temperature, increasing heat storage capacity and improving exercise performance in the heat. To date, the majority of precooling manoeuvres have been achieved via external means, such as cold water immersion and the application of cooling garments. However, these methods have been criticized for their lack of practicality for use in major sporting competitions. Recent evidence has shown that internal or endogenous cooling methods, such as drinking cold fluids or ice slurries, are able to lower core temperature and enhance endurance performance in the heat. These methods may be more advantageous than current forms of precooling, as ingesting cold fluids or ice slurries can be easily implemented in the field and provide the additional benefit of hydrating athletes. While the precise mechanisms responsible for these performance enhancements are yet to be fully explained, the effect of ice ingestion on brain temperature, internal thermoreception and sensory responses may be involved. This article addresses the evidence supporting the use of endogenous cooling methods for improving endurance performance in the heat, as well as discussing the potential mechanisms behind the improvements observed and providing practical recommendations to optimize their success.

  19. Heat transfer in two-component internal mist cooling

    Energy Technology Data Exchange (ETDEWEB)

    Novak, V.; Sadowski, D.L.; Schoonover, K.G.; Abdel-Khalik, S.I. [G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332-0405 (United States); Ghiaasiaan, S.M. [G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332-0405 (United States)], E-mail: mghiaasiaan@gatech.edu

    2008-09-15

    An experimental investigation was conducted to examine steady, internal, nozzle-generated, gas/liquid mist cooling in vertical channels. The ideal primary cooling mechanism in this situation is surface evaporation of an ultra-thin, subcooled liquid film that forms on the heated surface. The aim was to quantify the effects of various operating and design parameters on the cooling effectiveness. Parameters tested included the liquid atomization nozzle design, inlet flow condition (liquid mass fraction; carrier gas velocity, temperature and humidity; liquid temperature; liquid droplet size distribution; and gas/liquid combination), channel characteristics (cross-section geometry, length and surface wettability), and flow direction. Interest in this research has been motivated by the need for a highly efficient cooling mechanism in high-power lasers for inertial fusion reactor applications. A fully instrumented experimental test facility that included three cylindrical and two rectangular electrically heated test sections with different cross-sections and unheated entry lengths was used. The channel hydraulic diameters covered the range 16-26.7 mm, and the heated length-to-hydraulic-diameter ratio varied in the range from 23.3 to 51. Water was used as the mist liquid, with air or helium as the carrier gas. Three types of mist generating nozzles with significantly different spray characteristics were used. Local heat transfer coefficients, defined based on the temperature difference between the heated surface and the bulk gas, were obtained along the channels for a wide range of operating conditions. The data indicate that mist cooling can increase the heat transfer coefficient by more than an order of magnitude compared to forced convection using only the carrier gas.

  20. Practical aspects of monochromators developed for transmission electron microscopy

    Science.gov (United States)

    Kimoto, Koji

    2014-01-01

    A few practical aspects of monochromators recently developed for transmission electron microscopy are briefly reviewed. The basic structures and properties of four monochromators, a single Wien filter monochromator, a double Wien filter monochromator, an omega-shaped electrostatic monochromator and an alpha-shaped magnetic monochromator, are outlined. The advantages and side effects of these monochromators in spectroscopy and imaging are pointed out. A few properties of the monochromators in imaging, such as spatial or angular chromaticity, are also discussed. PMID:25125333

  1. Internally-cooled centrifugal compressor with cooling jacket formed in the diaphragm

    Science.gov (United States)

    Moore, James J.; Lerche, Andrew H.; Moreland, Brian S.

    2014-08-26

    An internally-cooled centrifugal compressor having a shaped casing and a diaphragm disposed within the shaped casing having a gas side and a coolant side so that heat from a gas flowing though the gas side is extracted via the coolant side. An impeller disposed within the diaphragm has a stage inlet on one side and a stage outlet for delivering a pressurized gas to a downstream connection. The coolant side of the diaphragm includes at least one passageway for directing a coolant in a substantially counter-flow direction from the flow of gas through the gas side.

  2. Realisation of a novel crystal bender for a fast double crystal monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Zaeper, R.; Richwin, M. E-mail: richwin@uni-wuppertal.de; Wollmann, R.; Luetzenkirchen-Hecht, D.; Frahm, R

    2001-07-21

    A novel crystal bender for an X-ray undulator beamline as part of a fast double crystal monochromator development for full EXAFS energy range was characterized. Rocking curves of the monochromator crystal system were recorded under different heat loads and bending forces of the indirectly cooled first Si(1 1 1) crystal. The monochromator development implements new piezo-driven tilt tables with wide angular range to adjust the crystals' Bragg angles and a high pressure actuated bender mechanism for the first crystal.

  3. Realisation of a novel crystal bender for a fast double crystal monochromator

    CERN Document Server

    Zaeper, R; Wollmann, R; Luetzenkirchen-Hecht, D; Frahm, R

    2001-01-01

    A novel crystal bender for an X-ray undulator beamline as part of a fast double crystal monochromator development for full EXAFS energy range was characterized. Rocking curves of the monochromator crystal system were recorded under different heat loads and bending forces of the indirectly cooled first Si(1 1 1) crystal. The monochromator development implements new piezo-driven tilt tables with wide angular range to adjust the crystals' Bragg angles and a high pressure actuated bender mechanism for the first crystal.

  4. Turbine airfoil with laterally extending snubber having internal cooling system

    Science.gov (United States)

    Scribner, Carmen Andrew; Messmann, Stephen John; Marsh, Jan H.

    2016-09-06

    A turbine airfoil usable in a turbine engine and having at least one snubber with a snubber cooling system positioned therein and in communication with an airfoil cooling system is disclosed. The snubber may extend from the outer housing of the airfoil toward an adjacent turbine airfoil positioned within a row of airfoils. The snubber cooling system may include an inner cooling channel separated from an outer cooling channel by an inner wall. The inner wall may include a plurality of impingement cooling orifices that direct impingement fluid against an outer wall defining the outer cooling channel. In one embodiment, the cooling fluids may be exhausted from the snubber, and in another embodiment, the cooling fluids may be returned to the airfoil cooling system. Flow guides may be positioned in the outer cooling channel, which may reduce cross-flow by the impingement orifices, thereby increasing effectiveness.

  5. Dimensional accuracy of internal cooling channel made by selective laser melting (SLM And direct metal laser sintering (DMLS processes in fabrication of internally cooled cutting tools

    Directory of Open Access Journals (Sweden)

    Ghani S. A. C.

    2017-01-01

    Full Text Available Selective laser melting(SLM and direct metal laser sintering(DMLS are preferred additive manufacturing processes in producing complex physical products directly from CAD computer data, nowadays. The advancement of additive manufacturing promotes the design of internally cooled cutting tool for effectively used in removing generated heat in metal machining. Despite the utilisation of SLM and DMLS in a fabrication of internally cooled cutting tool, the level of accuracy of the parts produced remains uncertain. This paper aims at comparing the dimensional accuracy of SLM and DMLS in machining internally cooled cutting tool with a special focus on geometrical dimensions such as hole diameter. The surface roughness produced by the two processes are measured with contact perthometer. To achieve the objectives, geometrical dimensions of identical tool holders for internally cooled cutting tools fabricated by SLM and DMLS have been determined by using digital vernier calliper and various magnification of a portable microscope. In the current study, comparing internally cooled cutting tools made of SLM and DMLS showed that generally the higher degree of accuracy could be obtained with DMLS process. However, the observed differences in surface roughness between SLM and DMLS in this study were not significant. The most obvious finding to emerge from this study is that the additive manufacturing processes selected for fabricating the tool holders for internally cooled cutting tool in this research are capable of producing the desired internal channel shape of internally cooled cutting tool.

  6. Internal target effects in ion storage rings with beam cooling

    Energy Technology Data Exchange (ETDEWEB)

    Gostishchev, Vitaly

    2008-06-15

    The accurate description of internal target effects is important for the prediction of operation conditions which are required for experiments in the planned storage rings of the FAIR facility. The BETACOOL code developed by the Dubna group has been used to evaluate beam dynamics in ion storage rings, where electron cooling in combination with an internal target is applied. Systematic benchmarking experiments of this code were carried out at the ESR storage ring at GSI. A mode with vanishing dispersion in the target position was applied to evaluate the influence of the dispersion function on the parameters when the target is heating the beam. The influence of the internal target on the beam parameters is demonstrated in the present work. A comparison of experimental results with simple models describing the energy loss of the beam particles in the target as well as with more sophisticated simulations with the BETACOOL code is given. In order to study the conditions which can be achieved in the proposed experiments the simulation results were quantitatively compared with experimental results and simulations for the ESR. The results of this comparison are discussed in the present thesis. BETACOOL simulations of target effects were performed for the NESR and the HESR of the future FAIR facility in order to predict the beam parameters for the planned experiments. (orig.)

  7. Double-crystal monochromator as the first optical element in BESSRC-CAT beamlines (abstract)

    Science.gov (United States)

    Beno, Mark A.; Ramanathan, Mohan

    1996-09-01

    The first optical element in the BESSRC-CAT beamlines at the Advanced Photon Source will be a monochromator, so that a standard design for this critical component is advantageous. The monochromator we have designed is a double-crystal, fixed-exit scheme with a constant offset designed for UHV operation, thereby allowing windowless operation of the beamlines. The crystals are mounted on a turntable with the first crystal at the center of rotation. A mechanical linkage is used to correctly position the second crystal and maintain a constant offset. The main drive for the rotary motion is provided by a vacuum-compatible Huber goniometer isolated from the main vacuum chamber. Rotary motion of the primary monochromator stage is accomplished by using two adjacent vacuum chambers connected only by the small annular opening around a hollow stainless steel shaft, which connects the Huber goniometer to the turntable on which the crystals are mounted. The design of the monochromator is such that it can accommodate both water and liquid nitrogen cooling for the crystal optics. The basic design for the monochromator linkage mechanism will be presented along with details of the monochromator chamber. The results of initial optical tests of the monochromator system using tilt sensors and a precision autocollimator will also be given.

  8. Optimization of operating parameters of internally cooled superconducting cables; Optimale Betriebsparameter fuer intern gekuehlte Supraleiterkabel

    Energy Technology Data Exchange (ETDEWEB)

    Katheder, H. [Max-Planck-Inst. fuer Plasmaphysik, Garching (Germany). NET Team

    1995-12-31

    Large superconducting coils such as are used for fusion experiments (Tokamak or Stellarator confiurations) are best equipped with internally cooled superconducting cables. These cables, which are cooled with helium at 4 Kcooled with minimum mass flow. The present paper deals with the thermodynamic behaviour of flowing helium in conduits and with the thermal load which may occur in a cable. It describes a mehtod of optimising the operating paramters and gives a numerical calculation using typical cable data. (orig.) [Deutsch] Bei grossen supraleitenden Spulen z.B. fuer Fusionsexperimente (Tokamak- oder Stellarator Anordnungen) werden mit Vorteil intern gekuehlte Supraleiterkabel eingesetzt. Seit einigen Jahren werden solche Kabel, gekuehlt mit Helium bei 4

  9. Air cooled turbine component having an internal filtration system

    Science.gov (United States)

    Beeck, Alexander R [Orlando, FL

    2012-05-15

    A centrifugal particle separator is provided for removing particles such as microscopic dirt or dust particles from the compressed cooling air prior to reaching and cooling the turbine blades or turbine vanes of a turbine engine. The centrifugal particle separator structure has a substantially cylindrical body with an inlet arranged on a periphery of the substantially cylindrical body. Cooling air enters centrifugal particle separator through the separator inlet port having a linear velocity. When the cooling air impinges the substantially cylindrical body, the linear velocity is transformed into a rotational velocity, separating microscopic particles from the cooling air. Microscopic dust particles exit the centrifugal particle separator through a conical outlet and returned to a working medium.

  10. Cooling system in a rotary piston internal combustion engine. Kuehlsystem einer Rotationskolbenbrennkraftmaschine

    Energy Technology Data Exchange (ETDEWEB)

    Eiermann, D.; Nuber, R.

    1991-05-23

    Cooling system of a trochoid-type rotary piston internal combustion engine with a liquid-cooled casing. First the coolant is conducted isochronically and in parallel through cooling chambers of the jacket and a side part of the casing from where it is transported by a cooling pump through the cooling chambers of the other side part, on past a thermostat and into a cooler positioned on this other side part. The cooler consists of a parallel connected pipe bundle whose finned pipes follow the radial outer contours of the casing of the machine. From the cooler the coolant is conducted back into the cooling chambers of the first side part and the jacket. A blower fitted on the eccentric shaft of the internal combustion engine inside the cooler takes in fresh air axially and discharges it radially through the finned pipes.

  11. Cooling water pump of a rotary piston internal combustion engine. Kuehlwasserpumpe einer Rotationskolbenbrennkraftmaschine

    Energy Technology Data Exchange (ETDEWEB)

    Eiermann, D.; Nuber, R.

    1991-05-23

    Spatial arrangement of a cooling pump of a trochoid-type rotary piston internal combustion engine with a liquid-cooled casing. First the coolant is conducted isochronically and in parallel through cooling chambers of the jacket and a side part into a common hollow space from where it is transported by the cooling pump into the other side part, on past a thermostat to a cooler located in the other side part and back into the cooling loop in the casing. The cooling pump is located in the jacket and its impeller is positioned in a cooling chamber of the other side part. Its shaft can be fitted with a speed controller for the fresh air supply and a lubricating pump.

  12. International working group on gas-cooled reactors. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-15

    The purpose of the meeting was to provide a forum for exchange of information on safety and licensing aspects for gas-cooled reactors in order to provide comprehensive review of the present status and of directions for future applications and development. Contributions were made concerning the operating experience of the Fort St. Vrain (FSV) HTGR Power Plant in the United States of America, the experimental power station Arbeitsgemeinschaft Versuchsreaktor (AVR) in the Federal Republic of Germany, and the CO/sub 2/-cooled reactors in the United Kingdom such as Hunterson B and Hinkley Point B. The experience gained at each of these reactors has proved the high safety potential of Gas-cooled Reactor Power Plants.

  13. Characteristics of Vacuum Freeze Drying with Utilization of Internal Cooling and Condenser Waste Heat for Sublimation

    Directory of Open Access Journals (Sweden)

    Muhammad Alhamid

    2013-09-01

    Full Text Available Vacuum freeze drying is an excellent drying method, but it is very energy-intensive because a relatively long drying time is required. This research investigates the utilization of condenser waste heat for sublimation as a way of accelerating the drying rate. In addition, it also investigates the effect of internal cooling combined with vacuum cooling in the pressure reduction process. Jelly fish tentacles were used as the specimen, with different configurations for condenser heat waste and internal cooling valve opening. The results show that heating with condenser heat waste can accelerate the drying rate up to 0.0035 kg/m2.s. In addition, pre-freezing by internal cooling prevents evaporation until the mass of the specimen is 0.47 g and promotes transition of the specimen into the solid phase.

  14. Laser cooling of internal degrees of freedom of molecules

    Science.gov (United States)

    Horchani, R.

    2016-08-01

    Optical pumping techniques using laser fields combined with photo-association of ultracold atoms leads to control of the vibrational and/or rotational population of molecules. In this study, we review the basic concepts and main steps that should be followed, including the excitation schemes and detection techniques used to achieve ro-vibrational cooling of Cs2 molecules. We also discuss the extension of this technique to other molecules. In addition, we present a theoretical model used to support the experiment. These simulations can be widely used for the preparation of various experiments because they allow the optimization of several important experimental parameters.

  15. On the influence of monochromator thermal deformations on X-ray focusing

    Science.gov (United States)

    Antimonov, M. A.; Khounsary, A. M.; Sandy, A. R.; Narayanan, S.; Navrotski, G.

    2016-06-01

    A cooled double crystal monochromator system is used on many high heat load X-ray synchrotron radiation beamlines in order to select, by diffraction, a narrow spectrum of the beam. Thermal deformation of the first crystal monochromator - and the potential loss of beam brightness - is often a concern. However, if downstream beam focusing is planned, the lensing effect of the monochromator must be considered even if thermal deformations are small. In this paper we report on recent experiments at an Advanced Photon Source (APS) beamline that focuses the X-ray beam using compound refractive lenses downstream of an X-ray monochromator system. Increasing the X-ray beam power by increasing the storage ring current from 100 mA to 130 mA resulted in an effective doubling of the focal distance. We show quantitatively that this is due to a lensing effect of the distorted monochromator that results in the creation of a virtual source downstream of the actual source. An analysis of the defocusing and options to mitigate this effect are explored.

  16. On the influence of monochromator thermal deformations on X-ray focusing

    Energy Technology Data Exchange (ETDEWEB)

    Antimonov, M.A. [Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607 (United States); X-ray Science Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Peter the Great St. Petersburg Polytechnic University, Saint Petersburg 195251 (Russian Federation); Khounsary, A.M., E-mail: amk@iit.edu [Department of Physics, Illinois Institute of Technology, Chicago, IL 60616 (United States); Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607 (United States); Sandy, A.R.; Narayanan, S.; Navrotski, G. [X-ray Science Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-06-01

    A cooled double crystal monochromator system is used on many high heat load X-ray synchrotron radiation beamlines in order to select, by diffraction, a narrow spectrum of the beam. Thermal deformation of the first crystal monochromator – and the potential loss of beam brightness – is often a concern. However, if downstream beam focusing is planned, the lensing effect of the monochromator must be considered even if thermal deformations are small. In this paper we report on recent experiments at an Advanced Photon Source (APS) beamline that focuses the X-ray beam using compound refractive lenses downstream of an X-ray monochromator system. Increasing the X-ray beam power by increasing the storage ring current from 100 mA to 130 mA resulted in an effective doubling of the focal distance. We show quantitatively that this is due to a lensing effect of the distorted monochromator that results in the creation of a virtual source downstream of the actual source. An analysis of the defocusing and options to mitigate this effect are explored.

  17. Internal coating of air cooled gas turbine blades

    Science.gov (United States)

    Ahuja, P. L.

    1979-01-01

    Six coating systems were evaluated for internal coating of decent stage (DS) eutectic high pressure turbine blades. Sequential deposition of electroless Ni by the hydrazine process, slurry Cr, and slurry Al, followed by heat treatment provided the coating composition and thickness for internal coating of DS eutectic turbine blades. Both NiCr and NiCrAl coating compositions were evaluated for strain capability and ductile to brittle transition temperature.

  18. Frequency stabilization of internal-mirror He-Ne lasers by air cooling.

    Science.gov (United States)

    Qian, Jin; Liu, Zhongyou; Shi, Chunying; Liu, Xiuying; Wang, Jianbo; Yin, Cong; Cai, Shan

    2012-09-01

    Instead of the traditional heating method, the cavity length of an internal-mirror He-Ne laser is controlled by air cooling which is implemented by a mini cooling fan. The responsive property of the cooling fan and the thermal expansion of the internal-mirror laser tube are investigated. According to these investigations, a controlling system is designed to drive the cooling fan controlling the cavity length of the laser. Then the frequency is stabilized by comparing the light intensities of two operating longitudinal modes. The results of beating with an iodine stabilized He-Ne laser show that a relative uncertainty (Δf/f-) of 4.3×10(-9) in 5 months, a frequency fluctuation of <1.4 MHz, and an Allan deviation of 6×10(-11) (τ=10,000 s) in 20 h are obtained.

  19. Thermo-Elastic Analysis of Internally Cooled Structures Using a Higher Order Theory

    Science.gov (United States)

    Arnold, Steven M.; Bednarcyk, Brett A.; Aboudi, Jacob

    2001-01-01

    This paper presents the results of a study on the thermomechanical behavior of internally cooled silicon nitride structures. Silicon nitride is under consideration for elevated temperature aerospace engine applications. and techniques for lowering the operating temperature of structures composed of this material are under development. Lowering the operating temperature provides a large payoff in terms of fatigue life and may be accomplished through the use of thermal barrier coatings (TBC's) and the novel concept of included cooling channels. Herein, an in-depth study is performed on the behavior of a flame-impinged silicon nitride plate with a TBC and internal channels cooled by forced air. The analysis is performed using the higher order theory for functionally graded materials (HOTFGM), which has been developed through NASA Glenn Research Center funding over the past several years. HOTFGM was chosen over the traditional finite element approach as a prelude to an examination of functionally graded silicon nitride structures for which HOTFGM is ideally suited. To accommodate the analysis requirement% of the internally cooled plate problem, two crucial enhancements were made to the two-dimensional Cartesian-based version of HOTFGM. namely, incorporation of internal boundary capabilities and incorporation of convective boundary conditions. Results indicate the viability and large benefits of cooling the plate via forced air through cooling channels. Furthermore, cooling can positively impact the stress and displacement fields present in the plate, yielding an additional payoff in terms of fatigue life. Finally, a spin-off capability resulted from inclusion of internal boundaries within HOTFGM; the ability to simulate the thermo-elastic response of structures with curved surfaces. This new capability is demonstrated, and through comparison with an analytical solution, shown to be viable and accurate.

  20. Fuel Economy Opportunities for Internal COmbustion Engines by Means of Oil—Cooling

    Institute of Scientific and Technical Information of China (English)

    C.F.Ma; J.C.Li; 等

    1997-01-01

    Comparative experiments of oil and water -cooling were performed on a 4-cylinder automotive gasoline engine and a single-cylinder direct injction Diesel engine.Measurements were made to investigate the variation of fuel consumption,combustor wall temperature and engine emissions(HC,CO,NOx and smoke)with two cooling media at steady-state conditions.Significant improvement of fuel econmy was found mainly at partial load conditions with oil-cooling in comparison with the baseline water-cooling both for the two engines.The experimental results also showed general trend of reduction in engine emissions using oil as the coolant,Measurements of wall temperature demonstrated that oil-cooling resulted in considerable increase of the combustor wall temperature and reduce of warm-up period in starting process.For automotive gasoline engine,road tests indicated the same trend of fuel economy improvement with oil-cooling.The performance of the automotive oil-cooled engine was further improved by internal cooling with water or methanol injection.

  1. Fuel economy opportunities for internal combustion engines by means of oil-cooling

    Science.gov (United States)

    Ma, C. F.; Li, J. C.; Qin, W. X.; Wei, Z. Y.; Chen, J.

    1997-06-01

    Comparative experiments of oil and water-cooling were performed on a 4-cylinder automotive gasoline engine and a single-cylinder direct injection Diesel engine. Measurements were made to investigate the variation of fuel consumption, combustor wall temperature and engine emissions (HC, CO, NOx and smoke) with two cooling media at steady-state conditions. Significant improvement of fuel economy was found mainly at partial load conditions with oil-cooling in comparison with the baseline water-cooling both for the two engines. The experimental results also showed general trend of reduction in engine emissions using oil as the coolant. Measurements of wall temperature demonstrated that oil-cooling resulted in considerable increase of the combustor wall temperature and reduce of warm-up period in starting process. For automotive gasoline engine, road tests indicated the same trend of fuel economy improvement with oil-cooling. The performance of the automotive oil-cooled engine was further improved by internal cooling with water or methanol injection.

  2. Analysis of Internal Cooling Geometry Variations in Gas Turbine Blades

    Institute of Scientific and Technical Information of China (English)

    M. Eifel; V. Caspary; H. H(o)nen; P. Jeschke

    2009-01-01

    The present investigation analyzes the effects of major geometrical modifications to the interior of a convection cooled gas turbine rotor blade. The main focus lies on the flow of the leading edge channels and the impact on the heat transfer. An experimental approach is performed with flow visualization via paint injection into water. Also numerical calculations are carried out in two sets, on the one hand water calculations accompanying the experi-ments and on the other hand conjugate heat transfer calculations under realistic engine conditions. The latter cal-culations are still ongoing delivering preliminary results. Five geometry configurations are investigated, three of them with differing turbulator arrangements in the leading edge channels. The operating point of the base configuration is set to Re = 50,000 at the inlet while for the modi-fied geometries the pressure ratio is held constant compared to the base. Among several investigated configurations one could be identified that leads to a heat transfer enhancement in one leading edge channel 7 % larger compared to the base.

  3. Vibrational stability of a cryocooled horizontal double-crystal monochromator

    Science.gov (United States)

    Kristiansen, Paw; Johansson, Ulf; Ursby, Thomas; Jensen, Brian Norsk

    2016-01-01

    The vibrational stability of a horizontally deflecting double-crystal monochromator (HDCM) is investigated. Inherently a HDCM will preserve the vertical beam stability better than a ‘normal’ vertical double-crystal monochromator as the vibrations of a HDCM will almost exclusively affect the horizontal stability. Here both the relative pitch vibration between the first and second crystal and the absolute pitch vibration of the second crystal are measured. All reported measurements are obtained under active cooling by means of flowing liquid nitrogen (LN2). It is found that it is favorable to circulate the LN2 at high pressures and low flow rates (up to 5.9 bar and down to 3 l min−1 is tested) to attain low vibrations. An absolute pitch stability of the second crystal of 18 nrad RMS, 2–2500 Hz, and a relative pitch stability between the two crystals of 25 nrad RMS, 1–2500 Hz, is obtained under cryocooling conditions that allow for 1516 W to be adsorbed by the LN2 before it vaporizes. PMID:27577758

  4. Monochromator design for the HADAS reflectometer in Jülich

    Science.gov (United States)

    Rücker, U.; Alefeld, B.; Kentzinger, E.; Brückel, Th

    2000-06-01

    A reflectometer with polarization analysis is being built on the basis of the HADAS spectrometer in the neutron guide hall at the research reactor FRJ-2 (DIDO) in Jülich. For obtaining the optimal flux at the sample position, the performances of several monochromator designs have been calculated, e.g. focusing mirrors, mosaic monochromator crystals and bent perfect crystal monochromators. Under the given geometrical limitations a double monochromator with bent perfect Si crystals and vertical focusing has the best performance.

  5. Effective temperature and exergy of monochromic blackbody radiation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A new parameter named monochromic effective temperature Tλ is proposed, which represents the thermodynamic quality of monochromic blackbody radiation. The exergy of the monochromic blackbody radiation is expressed by Tλ. The monochromic effective temperature equation is developed, which shows that the produci of Tλ and the wavelength is constant, which equals 5.33016×10-3 tion in photosynthesis can be explained by the results of this work.

  6. Computer-automated multi-disciplinary analysis and design optimization of internally cooled turbine blades

    Science.gov (United States)

    Martin, Thomas Joseph

    This dissertation presents the theoretical methodology, organizational strategy, conceptual demonstration and validation of a fully automated computer program for the multi-disciplinary analysis, inverse design and optimization of convectively cooled axial gas turbine blades and vanes. Parametric computer models of the three-dimensional cooled turbine blades and vanes were developed, including the automatic generation of discretized computational grids. Several new analysis programs were written and incorporated with existing computational tools to provide computer models of the engine cycle, aero-thermodynamics, heat conduction and thermofluid physics of the internally cooled turbine blades and vanes. A generalized information transfer protocol was developed to provide the automatic mapping of geometric and boundary condition data between the parametric design tool and the numerical analysis programs. A constrained hybrid optimization algorithm controlled the overall operation of the system and guided the multi-disciplinary internal turbine cooling design process towards the objectives and constraints of engine cycle performance, aerodynamic efficiency, cooling effectiveness and turbine blade and vane durability. Several boundary element computer programs were written to solve the steady-state non-linear heat conduction equation inside the internally cooled and thermal barrier-coated turbine blades and vanes. The boundary element method (BEM) did not require grid generation inside the internally cooled turbine blades and vanes, so the parametric model was very robust. Implicit differentiations of the BEM thermal and thereto-elastic analyses were done to compute design sensitivity derivatives faster and more accurately than via explicit finite differencing. A factor of three savings of computer processing time was realized for two-dimensional thermal optimization problems, and a factor of twenty was obtained for three-dimensional thermal optimization problems

  7. PREFACE: 7th International Conference on Cooling & Heating Technologies (ICCHT 2014)

    Science.gov (United States)

    2015-09-01

    The Kyoto protocol has initiated a pledge from almost all developing and developed countries to be committed to reducing CO2 emissions. Development of new renewable energy technologies are also of interest in this conference. Greenhouse gases have contributed to global warming and other man-made disasters. Cooling and Heating communities also have responsibilities towards the commitment of reducing the greenhouse gas emissions. In addition, depleting natural resources also act as a threat to the Cooling and Heating industries, causing them to develop highly efficient equipment and innovative technologies. The 1st International Conference on Cooling & Heating Technologies was held in Hanoi Vietnam (Jan. 2005). Whereas the 2nd, 3rd, 4th and 5th ICCHT conferences were held in Dalian, China (Jul. 2006), Tokyo, Japan (Jul. 2007), Jinhae, Korea (Oct. 2008) and Bandung, Indonesia (Dec. 2010) respectively. The 6th International Conference on Cooling & Heating Technologies (ICCTH2012) was held in Xi'an in China on November 9-12, 2012. It is our pleasure to welcome you to the 7th International Conference on Cooling & Heating Technologies (ICCTH2014) on 4th - 6th November 2014 at the Grand Dorsett Subang Hotel, Subang Jaya, Selangor Darul Ehsan, Malaysia The Theme of the Conference is ''Sustainability and Innovation in Heating & Cooling Technologies''. The sub-themes are:- • CO2 Reduction and Low Carbon Technologies • HVAC System and Natural Ventilation • Energy & Alternative Energy • Computational Fluid Dynamics • Low Temperature & Refrigeration Engineering In conjunction with the Conference, an Exhibition will be organized as an integral part of the Conference. Project experiences, product solutions, new applications and state-of-the art information will be highlighted.

  8. Thermal performance demonstration of a prototype internally cooled nose tip/forebody/window assembly

    Science.gov (United States)

    Wojciechowski, Carl J.; Brooks, Lori C.; Teal, Gene; Karu, Zain; Kalin, David A.; Jones, Gregory W.; Romero, Harold

    1996-11-01

    Internally liquid cooled apertures (windows) installed in a full size forebody have been characterized under high heat flux conditions representative of endoatmospheric flight. Analysis and test data obtained in the laboratory and at arc heater test facilities at Arnold Engineering Development Center and NASA Ames are presented in this paper. Data for several types of laboratory bench tests are presented: transmission interferometry and imaging, coolant pressurization effects on optical quality, and coolant flow rate calibrations for both the window and other internally cooled components. Initially, using heat transfer calibration models identical in shape to the flight test articles, arc heater facility thermal test environments were obtained at several conditions representative of full flight thermal environments. Subsequent runs tested the full-up flight article including nosetip, forebody and aperture for full flight duplication of surface heating rates and exposure ties. Pretest analyses compared will to test measurements. These data demonstrate a very efficient internal liquid cooling design which can be applied to other applications such as cooled mirrors for high heat flux applications.

  9. Frequency stabilization of internal-mirror He-Ne lasers by air cooling

    Science.gov (United States)

    Qian, Jin; Liu, Zhongyou; Shi, Chunying; Liu, Xiuying; Wang, Jianbo; Yin, Cong; Cai, Shan

    2013-01-01

    Instead of traditional heating method, the cavity length of an internal-mirror He-Ne laser is controlled by air cooling which is generated by a mini cooling fan. A PID servo controlling system is designed to drive the cooling fan tuning the frequency of the laser. The frequency is stabilized by balancing the power of two operating longitudinal modes. Beating with an iodine stabilized He-Ne laser, a relative uncertainty(Δf / ̅f ) of 4.3×10-9 in 5 months, a frequency fluctuation of less than 2.6 MHz and an Allan deviation of 3×10-11 (τ=100 s) in 75 h are obtained.

  10. Solar Multi-stage Refrigeration Systems on the Basis of Absorber with the Internal Evaporative Cooling

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2015-08-01

    Full Text Available In the article, the developed schematics are presented for the alternative refrigeration systems and air-conditioning systems, based on the use of absorbing cycle and solar energy for the regeneration of absorbent solution. Multi-stage principle of construction of drying and cool contours of solar systems is used with growth of concentration of absorbent on the stages of cooler. An absorber with internal evaporative cooling, allowing to remove the separate evaporated cooler, usually included after the absorber of the proper stage, is developed. Heat-mass-transfer apparatus of film-type, entering in the complement of drying and cool contours compatible and executed on the basis of multichannel compositions from polymeric materials. The preliminary comparative analysis of possibilities of the solar refrigeration systems and air-conditioning systems is executed.

  11. Heat transfer technology for internal passages of air-cooled blades for heavy-duty gas turbines.

    Science.gov (United States)

    Weigand, B; Semmler, K; von Wolfersdorf, J

    2001-05-01

    The present review paper, although far from being complete, aims to give an overview about the present state of the art in the field of heat transfer technology for internal cooling of gas turbine blades. After showing some typical modern cooled blades, the different methods to enhance heat transfer in the internal passages of air-cooled blades are discussed. The complicated flows occurring in bends are described in detail, because of their increasing importance for modern cooling designs. A short review about testing of cooling design elements is given, showing the interaction of the different cooling features as well. The special focus of the present review has been put on the cooling of blades for heavy-duty gas turbines, which show several differences compared to aero-engine blades.

  12. New method for spectrofluorometer monochromator wavelength calibration.

    Science.gov (United States)

    Paladini, A A; Erijman, L

    1988-09-01

    A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment.

  13. Analysis of flavor and perfume using an internally cooled coated fiber device.

    Science.gov (United States)

    Chen, Yong; Begnaud, Frédéric; Chaintreau, Alain; Pawliszyn, Janusz

    2007-05-01

    A miniaturized internally cooled coated fiber device was applied for the analysis of flavors and fragrances from various matrices. Its integration with a CTC CombiPAL autosampler enabled high throughput for the analysis of analytes in complex matrices that required simultaneous heating of the matrices and cooling of the fiber coating to achieve high extraction efficiency. It was found that up to ten times increase of extraction efficiencies was observed when the device was used to extract flavor compounds in water, even when limited sample temperatures were used to preserve the integrity of target compounds. The extraction of the flavor compounds in water with the device was reproducible, with RSD not larger than 15%. The lower limits of the linear ranges were in the low ppb range, which was about one order of magnitude smaller than those obtained with the commercialized 100 microm PDMS fibers. Exhaustive extraction of some perfume ingredients from a complex matrix (shampoo) was realized. All achieved recoveries were not less than 80%. The repeatability of the extraction of the perfume compounds from shampoo was better than 10%. The linear ranges were about 1-3000 microg/g, and the LOD was about 0.2-1 microg/g. The automated internally cooled coated fiber device was demonstrated to be a powerful sample preparation tool in flavor and fragrance analysis.

  14. Conjugate Heat Transfer of an Internally Air-Cooled Nozzle Guide Vane and Shrouds

    Directory of Open Access Journals (Sweden)

    Leiyong Jiang

    2014-04-01

    Full Text Available In order to assess the life of gas turbine critical components, it is essential to adequately specify their aerothermodynamic working environments. Steady-state analyses of the flow field and conjugate heat transfer of an internally air-cooled nozzle guide vane (NGV and shrouds of a gas turbine engine at baseline operating conditions are numerically investigated. A high-fidelity CFD model is generated and the simulations are carried out with properly defined boundary conditions. The features of the complicated flow and temperature fields are revealed. In general, the Mach number is lower and the temperature is higher on the NGV pressure side than those on the suction side. There are two high temperature regions on the pressure side, and the temperature across the middle section is relatively low. These findings are closely related to the locations of the holes and outlets of the cooling flow passage, and consistent with the field observations of damaged NGVs. As a technology demonstration, the results provide required information for the life analysis of the NGV/shrouds assembly and improvement of the cooling flow arrangement.

  15. High heat flux x-ray monochromators: What are the limits?

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, C.S.

    1997-06-01

    First optical elements at third-generation, hard x-ray synchrotrons, such as the Advanced Photon Source (APS), are subjected to immense heat fluxes. The optical elements include crystal monochromators, multilayers and mirrors. This paper presents a mathematical model of the thermal strain of a three-layer (faceplate, heat exchanger, and baseplate), cylindrical optic subjected to narrow beam of uniform heat flux. This model is used to calculate the strain gradient of a liquid-gallium-cooled x-ray monochromator previously tested on an undulator at the Cornell High Energy Synchrotron Source (CHESS). The resulting thermally broadened rocking curves are calculated and compared to experimental data. The calculated rocking curve widths agree to within a few percent of the measured values over the entire current range tested (0 to 60 mA). The thermal strain gradient under the beam footprint varies linearly with the heat flux and the ratio of the thermal expansion coefficient to the thermal conductivity. The strain gradient is insensitive to the heat exchanger properties and the optic geometry. This formulation provides direct insight into the governing parameters, greatly reduces the analysis time, and provides a measure of the ultimate performance of a given monochromator.

  16. A soft X-ray plane-grating monochromator optimized for elliptical dipole radiation from modern sources

    Energy Technology Data Exchange (ETDEWEB)

    Kachel, Torsten, E-mail: torsten.kachel@helmholtz-berlin.de; Eggenstein, Frank [Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Follath, Rolf [Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-07-14

    The utilization of elliptical dipole radiation in a collimated plane-grating monochromator at BESSY II is described. A new but yet well proven way of making elliptically polarized dipole radiation from the BESSY II storage ring applicable to the SX700-type collimated plane-grating monochromator PM3 is described. It is shown that due to the limited vertical acceptance of the grating a simple use of vertical apertures is not possible in this case. Rather, deflecting the beam upwards or downwards by rotating the vertically collimating toroidal mirror M1 around the light axis leads to excellent performance. The resulting detuning of the photon energy can be taken into account by a readjustment of the monochromator internal plane mirror M2. The energy resolution of the beamline is not affected by the non-zero ‘roll’ of the collimating mirror.

  17. Using internally cooled cutting tools in the machining of difficult-to-cut materials based on Waspaloy

    Directory of Open Access Journals (Sweden)

    Yahya Isik

    2016-05-01

    Full Text Available Nickel-based superalloys such as Waspaloy are used for engine components and in the nuclear industry, where considerable strength and corrosion resistance at high operating temperatures are called for. These characteristics of such alloys cause increases in cutting temperature and resultant tool damage, even at low cutting speeds and low feed rates. Thus, they are classified as difficult-to-cut materials. This article presents a cooling method to be used in metal cutting based on a tool holder with a closed internal cooling system with cooling fluid circulating inside. Hence, a green cooling method that does not harm the environment and is efficient in removing heat from the cutting zone was developed. A series of cutting experiments were conducted to investigate the practicality and effectiveness of the internally cooled tool model. The developed system achieved up to 13% better surface quality than with dry machining, and tool life was extended by 12%. The results clearly showed that with the reduced cutting temperature of the internal cooling, it was possible to control the temperature and thus prevent reaching the critical cutting temperature during the turning process, which is vitally important in extending tool life during the processing of Waspaloy.

  18. 1-40-keV fixed-exit monochromator for a wafer mapping TXRF facility

    Science.gov (United States)

    Comin, Fabio; Apostolo, G.; Freund, Andreas K.; Mangiagalli, P.; Navizet, M.; Troxel, C. L.

    1998-12-01

    An industrial facility for the mapping of trace impurities on the surface of 300 mm Silicon wafers will be commissioned at the end of 1998. The elements to be detected range from Na to Hg with a target routine detection limit of 108 atoms/cm2. The monochromator of the facility plays a central role and fulfills the following requirements: ease of operations and fast tuning (one single motor); extended energy range (1 - 40 KeV covered by a fixed exit Si(111) channel cut and multilayer pair); smooth and reliable running (water cooling even in the powerful ESRF undulator beams at high energies). The mechanical structure of the monochromator is based on well-established concepts: an external goniometer transfers the main rotation to the in-vacuum plateau via a hollow differentially pumped feed-through. The optical arrangement shows some novelties: the plateau can be cooled either by water or liquid nitrogen and it holds the convex- concave machined Si(111) channel-cut for fixed exit performances. The shape of the machined surfaces of the crystal helps also on to spread the power density of the beam on the silicon surface. A set of two identical multilayers are also mounted on the plateau and the transition from the Si(111) crystal to the multilayer operation is performed by rotating the wafer main axis by about 180 degrees. The whole facility is centered around the three main components: the monochromator, the wafer handling robots and the two linear arrays of solid state fluorescence detectors.

  19. Effect of internal coolant crossflow orientation on the discharge coefficient of shaped film-cooling holes

    Energy Technology Data Exchange (ETDEWEB)

    Gritsch, M.; Saumweber, C.; Schulz, A.; Wittig, S.; Sharp, E.

    2000-01-01

    Discharge coefficients of three film-cooling hole geometries are presented over a wide range of engine like conditions. The hole geometries comprise a cylindrical hole and two holes with a diffuser-shaped exit portion (a fanshaped and a laidback fanshaped hole). For all three hole geometries the hole axis was inclined 30 deg with respect to the direction of the external (hot gas) flow. The flow conditions considered were the hot gas crossflow Mach number (up to 0.6), the coolant crossflow Mach number (up to 0.6) and the pressure ratio across the hole (up to 2). The effect of internal crossflow approach direction, perpendicular or parallel to the main flow direction, is particularly addressed in the present study. Comparison is made of the results for a parallel and perpendicular orientation, showing that the coolant crossflow orientation has a strong impact on the discharge behavior of the different hole geometries. The discharge coefficients were found to strongly depend on both hole geometry and crossflow conditions. Furthermore, the effects of internal and external crossflow on the discharge coefficients were described by means of correlations used to derive a predicting scheme for discharge coefficients. A comparison between predictions and measurements reveals the capability of the method proposed.

  20. Monochromator-Based Absolute Calibration of a Standard Radiation Thermometer

    Science.gov (United States)

    Mantilla, J. M.; Hernanz, M. L.; Campos, J.; Martín, M. J.; Pons, A.; del Campo, D.

    2014-04-01

    Centro Español de Metrología (CEM) is disseminating the International Temperature Scale (ITS-90), at high temperatures, by using the fixed points of Ag and Cu and a standard radiation thermometer. However, the future mise-en-pratique for the definition of the kelvin ( MeP-K) will include the dissemination of the kelvin by primary methods and by indirect approximations capable of exceptionally low uncertainties or increased reliability. Primary radiometry is, at present, able to achieve uncertainties competitive with the ITS-90 above the silver point with one of the possible techniques the calibration for radiance responsivity of an imaging radiometer (radiance method). In order to carry out this calibration, IO-CSIC (Spanish Designated Institute for luminous intensity and luminous flux) has collaborated with CEM, allowing traceability to its cryogenic radiometer. A monochromator integrating sphere-based spectral comparator facility has been used to calibrate one of the CEM standard radiation thermometers. The absolute calibrated standard radiation thermometer has been used to determine the temperatures of the fixed points of Cu, Co-C, Pt-C, and Re-C. The results obtained are 1357.80 K, 1597.10 K, 2011.66 K, and 2747.64 K, respectively, with uncertainties ranging from 0.4 K to 1.1 K.

  1. Multipurpose monochromator for the Basic Energy Science Synchrotron Radiation Center Collaborative Access Team beamlines at the Advanced Photon Source x-ray facility

    Science.gov (United States)

    Ramanathan, M.; Beno, M. A.; Knapp, G. S.; Jennings, G.; Cowan, P. L.; Montano, P. A.

    1995-02-01

    The Basic Energy Science Synchrotron Radiation Center (BESSRC) Collaborative Access Team (CAT) will construct x-ray beamlines at two sectors of the Advanced Photon Source facility. In most of the beamlines the first optical element will be a monochromator, so that a standard design for this critical component is advantageous. The monochromator is a double-crystal, fixed exit scheme with a constant offset designed for ultrahigh vacuum windowless operation. In this design, the crystals are mounted on a turntable with the first crystal at the center of rotation. Mechanical linkages are used to correctly position the second crystal and maintain a constant offset. The main drive for the rotary motion is provided by a vacuum compatible Huber goniometer isolated from the main vacuum chamber. The design of the monochromator is such that it can accommodate water, gallium, or liquid-nitrogen cooling for the crystal optics.

  2. Post-recombination early Universe cooling by translation-internal inter-conversion: The role of minor constituents.

    Science.gov (United States)

    McCaffery, Anthony J

    2015-09-14

    Little is known of the mechanism by which H and H2, the principal constituents of the post-re-combination early Universe, cooled sufficiently to permit cluster formation, nucleosynthesis, and, eventually, the formation of structured objects. Radiative decay primarily cools the internal modes of H2, as Δj = - 2 jumps accompany quadrupolar emission. This, however, would be a self-limiting mechanism. In this work, a translational energy cooling mechanism based on collision-induced, translation-to-internal mode conversion, is extended, following an earlier study [A. J. McCaffery and R. J. Marsh, J. Chem. Phys. 139, 234310 (2013)] of ensembles comprising H2 in a H atom bath gas. Here, the possible influence of minor species, such as HD, on this cooling mechanism is investigated. Results suggest that the influence of HD is small but not insignificant. Conversion is very rapid and an overall translation-to-internal energy conversion efficiency of some 5% could be expected. This finding may be of use in the further development of models of this complex phase of early Universe evolution. An unexpected finding in this study was that H2 + HD ensembles are capable of very rapid translation-to-internal conversion with efficiencies of >40% and relaxation rates that appear to be relatively slow. This may have potential as an energy storage mechanism.

  3. Post-recombination early Universe cooling by translation–internal inter-conversion: The role of minor constituents

    Energy Technology Data Exchange (ETDEWEB)

    McCaffery, Anthony J., E-mail: A.J.McCaffery@sussex.ac.uk [Department of Chemistry, University of Sussex, Brighton, BN1 9QJ Sussex (United Kingdom)

    2015-09-14

    Little is known of the mechanism by which H and H{sub 2}, the principal constituents of the post-re-combination early Universe, cooled sufficiently to permit cluster formation, nucleosynthesis, and, eventually, the formation of structured objects. Radiative decay primarily cools the internal modes of H{sub 2}, as Δj = − 2 jumps accompany quadrupolar emission. This, however, would be a self-limiting mechanism. In this work, a translational energy cooling mechanism based on collision-induced, translation-to-internal mode conversion, is extended, following an earlier study [A. J. McCaffery and R. J. Marsh, J. Chem. Phys. 139, 234310 (2013)] of ensembles comprising H{sub 2} in a H atom bath gas. Here, the possible influence of minor species, such as HD, on this cooling mechanism is investigated. Results suggest that the influence of HD is small but not insignificant. Conversion is very rapid and an overall translation-to-internal energy conversion efficiency of some 5% could be expected. This finding may be of use in the further development of models of this complex phase of early Universe evolution. An unexpected finding in this study was that H{sub 2} + HD ensembles are capable of very rapid translation-to-internal conversion with efficiencies of >40% and relaxation rates that appear to be relatively slow. This may have potential as an energy storage mechanism.

  4. Design and analysis of a high heat load pin-post monochromator crystal with an integral water manifold

    Energy Technology Data Exchange (ETDEWEB)

    Schildkamp, W. [Consortium for Advanced Radiation Sources, University of Chicago, 5640 S. Ellis Ave., Chicago, IL 60637 (United States); Tonnessen, T. [Rocketdyne Albuquerque Operations, 2511 C. Broadbent Parkway, N.E., Albuquerque, NM 87107 (United States)

    1996-09-01

    Conventional minichannel water cooling geometry will not perform satisfactorily for x-radiation from a wiggler source at the Advanced Photon Source. For closed-gap wiggler operation, cryogenic silicon appears to be the only option for crystals in Bragg-Bragg geometry. For operation of the wiggler at more modest critical energies ({lt}17 keV), the first crystal can be cooled by a pin-post cooling scheme, using water at room temperature as a coolant. In order to limit the water consumption to 4 gpm and hence the risk of introducing vibrations to the crystal, the intensely cooled area of the crystal was matched to the footprint of the beam, leaving a less cooled area of the crystal subject to survival in a missteered beam but not to perform as a monochromator. The manifold design avoids large areas of high water pressure that would bow the crystal. We present here the design of a pin-post monochromator consisting of a four-layer silicon manifold system and an integrally bonded 39{percent} nickel-iron alloy base plate. A transparent prototype of the design will be exhibited. Fabrication techniques and design advantages will be discussed. {copyright} {ital 1996 American Institute of Physics.}

  5. Thermal investigation of an internally cooled strut injector for scramjet application at moderate and hot gas conditions

    Science.gov (United States)

    Dröske, Nils C.; Förster, Felix J.; Weigand, Bernhard; von Wolfersdorf, Jens

    2017-03-01

    In this paper, we present a combined experimental and numerical approach to assess the thermal loads and the cooling mechanism of an internally cooled strut injector for a supersonic combustion ramjet. Infrared measurements of the injector surface are conducted at a moderate external flow temperature. In addition, the main flow field is investigated with the LITA technique. Main features of the cooling mechanism are identified based on experimental data. However, a full evaluation can only be obtained using a complex, conjugate CFD simulation, which couples the external and internal flow fields to the heat conduction inside the injector body. Furthermore, numerical simulations are also presented for hot gas conditions corresponding to combustion experiments. Both hydrogen, which would be used as fuel for flight tests, and air are considered as coolants. While the main features of the cooling mechanism will be shown to remain unchanged, the combustor wall temperature is found to have a significant influence on the cooling. This emphasizes the importance and the usefulness of such complex conjugate numerical simulations.

  6. Design, Build & Test of a Double Crystal Monochromator for Beamlines I09 & I23 at the Diamond Light Source

    Science.gov (United States)

    Kelly, J.; Lee, T.; Alcock, S.; Patel, H.

    2013-03-01

    A high stability Double Crystal Monochromator has been developed at The Diamond Light Source for beamlines I09 and I23. The design specification was a cryogenic, fixed exit, energy scanning monochromator, operating over an energy range of 2.1 - 25 keV using a Si(111) crystal set. The novel design concepts are the direct drive, air bearing Bragg axis, low strain crystal mounts and the cooling scheme. The instrument exhibited superb stability and repeatability on the B16 Test Beamline. A 20 keV Si(555), 1.4 μrad rocking curve was demonstrated. The DCM showed good stability without any evidence of vibration or Bragg angle nonlinearity.

  7. BACK CHIP TEMPERATURE IN ENVIRONMENTALLY CONSCIOUS TURNING WITH CONVENTIONAL AND INTERNALLY COOLED CUTTING TOOLS

    Directory of Open Access Journals (Sweden)

    Saiful Anwar Che Ghani

    2013-06-01

    Full Text Available Central to machining processes is the interaction between the tool insert and the chip of material removed from the blank. Chip-insert interaction occurs when the chip slides on the rake face of the insert. Heat is generated by the friction inherent to this sliding process. The temperature in the cutting zone of both the insert and the chip rises, usually facilitating adhesion, diffusion, and more complex chemical and physical phenomena between the insert and the chip. These effects accelerate the insert wear, ultimately undermining the tool life. Thus, a number of methods have been developed to control heat generation. Most typically, metal working fluids are conveyed onto the rake face in the cutting zone. However, this solution may be not ideal from the point of view of cost, the environment, and contamination of the part, which may be unacceptable, for example, in healthcare and optical applications. In this study, microfluidic structures internal to the insert are examined as a means of controlling the heat generation.Conventional and internallycooled tools were compared in dry turning of AA6082-T6 aluminum alloy in two 3  3 factorial experiments of different machining conditions. Statistical analyses support the conclusion that chip temperature depends only on the depth of cut,and not on the feed rate or cutting speed. They also show that the benefit of cooling the insert internally increases as the depth of cut increases. Therefore, internallycooled tools can be particularly advantageous in roughing operations.

  8. Effect of Internal Heat Recovery in Ammonia-Water Absorption Cooling Cycles: Exergy and Structural Analysis

    Directory of Open Access Journals (Sweden)

    Miquel Nogués

    2009-03-01

    Full Text Available First and second law analysis have been conducted for three low temperature driven ammonia-water absorption cooling cycles with increasing internal heat recovery. Based on the results of exergy analysis the structural analysis has been achieved. The obtained Coefficients of Structural Bonds (CSB consider how the irreversibility of the whole cycle is affected by a change in the irreversibility related to an efficiency improvement of a single component. Trends for the different configurations are similar, while quantitative differences among the main heat exchangers are considerable. The highest values of the CSB are found for the refrigerant heat exchanger. Also the evaporator, the condenser, the generator and the absorber show values higher than unity. The lowest CSB’s are obtained in the solution heat exchanger. In general, CSB’s decrease with increasing efficiency. That means that for very efficient heat exchangers, a further improvement looks less attractive. The dephlegmator is an exception as it shows a singularity of the CSB value due to its complex interactions with the other components. Once the CSB’s are obtained for the main components, they can be used in the structural method of the thermoeconomic optimisation. This method enables us to find the optimum design of a component in a straightforward calculation.

  9. Develop and test an Internally Cooled, Cabled Superconductor (ICCS) for large scale MHD magnets

    Science.gov (United States)

    Marston, P. G.; Hale, J. R.; Dawson, A. M.

    1990-04-01

    The work included four principal tasks: (1) development of a design requirements definition for a retrofit MHD magnet system; (2) analysis of an internally cooled, cabled superconductor (ICCS) to use in that design; (3) design of an experiment to test a subscale version of that conductor, which is a NbTi, copper stabilized superconductor; and (4) proof-of-concept testing of the conductor. The program was carried forth through the third task with very successful development and test of a conventional ICCS conductor with 27 multifilamentary copper-superconductor composite strands and a new concept conductor in which, in each triplet, two strands were pure copper and the third strand was a multifilamentary composite. In reviewing the magnet design and the premises for the conductor design it became obvious that an extra barrier might be highly effective in enhancing magnet stability and protection. This concept was developed and a sample conductor manufactured and tested in comparison with an identical conductor lacking such an additional barrier. Results of these conductor tests confirm the potential value of such a barrier. Since the work of tasks 1 through 3 has been reported in detail in quarterly and semiannual reports, as well as in special reports prepared throughout the course of this project, this report reviews early work briefly and then discusses this last phase in great detail.

  10. Impact of Decoherence on Internal State Cooling using Optical Frequency Combs

    CERN Document Server

    Malinovskaya, S A

    2012-01-01

    We discuss femtosecond Raman type techniques to control molecular vibrations, which can be implemented for internal state cooling from Feshbach states with the use of optical frequency combs with and without modulation. The technique makes use of multiple two-photon resonances induced by optical frequencies present in the comb. It provides us with a useful tool to study the details of molecular dynamics at ultracold temperatures. In our theoretical model we take into account decoherence in the form of spontaneous emission and collisional dephasing in order to ascertain an accurate model of the population transfer in the three-level system. We analyze the effects of odd and even chirps of the optical frequency comb in the form of sine and cosine functions on the population transfer. We compare the effects of these chirps to the results attained with the standard optical frequency comb to see if they increase the population transfer to the final deeply bound state in the presence of decoherence. We also analyze...

  11. Study of a scattering shield in a high heat load monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Rong, E-mail: rh66@cornell.edu [IMCA-CAT, Hauptman-Woodward Institute (United States); Meron, Mati [CARS, The University of Chicago (United States)

    2013-07-11

    The techniques for the cooling of the first crystal of a monochromator are by now mature and are used routinely to deal with the heat loads resulting from the intense beams generated by third generation synchrotron insertion device sources. However, the thermal stability of said monochromators, which crucially depends on proper shielding of X-ray scattering off the first crystal, remains a serious consideration. This will become even more so in the near future, as many synchrotron facilities are upgrading to higher beam currents and energies. During a recent upgrade of the 17-ID beamline at the APS it was recognized that accurate simulation of the spatial distribution of the power scattered off the first crystal was essential for the understanding and remediation of the observed large temperature increase of the first crystal's scattering shield. The calculation is complex, due to the broad energy spectrum of the undulator and the prevalence of multiple X-ray scattering events within the bulk of the crystal, thus the Monte Carlo method is the natural tool for such a task. A successful simulation was developed, for the purpose of the 17-ID upgrade, and used to significantly improve the design of the first crystal's scattering shield. -- Highlights: • We use the Monte Carlo method to simulate X-ray scattering from monochromator crystals. • Scattered X-ray power on each surface of the scattering shield has been calculated. • Overheating on the original shield is well explained with simulated scattering power. • The thermal stability of the modified scattering shield is satisfactory.

  12. COGENERATION OPPORTUNITIES TO IMPROVE THE EFFICIENCY OF MICRO HEAT POWER PLANTS BASED ON AIR COOLED INTERNAL COMBUSTION ENGINES

    Directory of Open Access Journals (Sweden)

    P. A. Shchinnikov

    2017-01-01

    Full Text Available The possibilities of operation of electric generators based on internal combustion engines with air cooling under conditions of cogeneration, when, along with the electricity, heat release in different embodiments is provided. Such facilities are usually realized on the basis of gasoline internal combustion engines (i.e. gasoline is used as a fuel. They can be used in the household, by professional builders, geologists, the military and rescuers in the area of emergencies and in areas with a lack of infrastructure. The basis of the facility is the gasoline generator Hitachi-2400 with an air-cooled power of 2.4 kW. The basic methodology for the study of microthermal power plants based on an air-cooled internal combustion engine which is based on balance equations is presented. The facility operation ensures the measurement of all temperatures and expenses of operating environments for determining heat flow in accordance with the proposed methodology. The specifications of heat exchangers for utilizing the heat of exhaust flue gases are presented. The energy diagram illustrating the useful effect of the application of various heat exchangers are plotted. Cogeneration possibilities of the facility are provided, firstly, by the release of heat with the air that cools a cylinder of the internal combustion engine, and, secondly, by the release of heat of hot water heated by utilizing the heat of the leaving flue gases, and, thirdly, in the calculated version, by the release of heat with air that is sequentially heated due to the cooling of the cylinder head and then by utilizing the heat of exhaust gases. It is demonstrated that the fuel heat utilization factor can be increased from 0.22 to 0.50–0.60, depending on the adopted technical solutions.

  13. Monochromator development at 4W1B beamline of BSRF

    Science.gov (United States)

    Xie, Yaning; Yan, Y.; Hu, T. D.; Liu, T.; Xian, D. C.

    2001-07-01

    The 4W1B is a X-ray monochromator beamline for XAFS at BSRF. During the upgrading phase, we have redesigned the monochromator to improve the performance of the beamline. It is a goniometer based, fixed exit double crystal monochromator. A mechanical linkage is employed to adjust the distance between the surfaces of the two crystals as the Bragg angle is changed to keep the outgoing beam direction constant. The whole mechanism is driven by only one stepping motor. The testing result shows that over the scanning range of 5-30°, the shift of outgoing beam position is less then 70 μm in the vertical direction. The basic principle, the mechanical realization, and the error analysis are discussed in detail. The performance and the testing results are also presented in this paper.

  14. Monochromator development at 4W1B beamiline of BSRF

    Institute of Scientific and Technical Information of China (English)

    YaningXie; Y.Yan; T.D.Hu; T.Liu; D.C.Xian

    2001-01-01

    The 4W1B is a X-ary monochromator beamline for XAFS at BSRF.During the upgrading phase,we have redsigned the monochromator to improve the performnce of beamline.It is a goniometer based,fixed exit double crystal monochromator.A mechanical linkage is employed to adjust the distance between the surfaces of the two crystals as the Bragg angle is changed to keep the outgoing beam direction constant.The whole mechanism is driven by only one stepping motor.The testing result shows that over the scanning range of 5-30°,the shift of outgoing beam position is less then 70μm in the vertical direction.The basic principle,the mechanical realization,and the error analysis are discussed in detail.The performance and the testing results are also presented in this paper.2001 Elsevier Science B.V.All rights reserved.

  15. A hard X-ray laboratory for monochromator characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamelin, B. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    Since their installation at ILL during the 1970`s the ILL {gamma}-ray diffractometers have been intensively used in the development of neutron monochromators. However, the ageing of the sources and new developments in hard X-ray diffractometry lead to a decision at the end of 1995 to replace the existing {gamma}-ray laboratory with a hard X-ray laboratory, based on a 420 keV generator, making available in the long term several beam-lines for rapid characterisation of monochromator crystals. The facility is now installed and its characteristics and advantages are outlined. (author). 2 refs.

  16. Develop and test an internally cooled, cabled superconductor (ICCS) for large scale MHD magnets

    Energy Technology Data Exchange (ETDEWEB)

    Marston, P.G.; Hale, J.R.; Dawson, A.M.

    1990-04-30

    The work conducted under DOE/PETC Contract DE-AC22-84PC70512 has included four principal tasks, (1) development of a Design Requirements Definition for a retrofit MHD magnet system, (2) analysis of an internally cooled, cabled superconductor (ICCS) to use in that design, (3) design of an experiment to test a subscale version of that conductor, which is a NbTi, copper stabilized superconductor, and (4) proof-of-concept testing of the conductor. The program was carried forth through the third task with very successful development and test of a conventional ICCS conductor with 27 multifilamentary copper-superconductor composite strands and a new concept conductor in which, in each triplet, two strands were pure copper and the third strand was a multifilamentary composite. In reviewing the magnet design and the premises for the conductor design it became obvious that, since the principal source of perturbation in MHD magnets derives from slippage between coils, or between turns in a coil, thereby producing frictional heat which must flow through the conductor sheath and the helium to the superconductor strands, an extra barrier might be highly effective in enhancing magnet stability and protection. This concept was developed and a sample conductor manufactured and tested in comparison with an identical conductor lacking such an additional barrier. Results of these conductor tests confirm the potential value of such a barrier. As the work of tasks 1 through 3 has been reported in detail in quarterly and semiannual reports, as well as in special reports prepared throughout the course of this project, this report reviews early work briefly and then discusses this last phase in great detail. 8 refs., 36 figs.

  17. Cooling of a Diesel Reformate Fuelled Solid Oxide Fuel Cell by Internal Reforming of Methane: A Modelling Study

    Institute of Scientific and Technical Information of China (English)

    HUANG Xiaowei; Alexander Kromp

    2013-01-01

    In this paper a system combining a diesel reformer using catalytic partial oxidation (CPOX) with the Solid Oxide Fuel Cell (SOFC) for Auxiliary Power Unit (APU) applications is modeled with respect to the cooling effect provided by internal reforming of methane in anode gas channel.A model mixture consisting of 80% n-hexadecane and 20% 1-methylnaphthalin is used to simulate the commercial diesel.The modelling consists of several steps.First,equilibrium gas composition at the exit of CPOX reformer is modelled in terms oxygen to carbon (O/C) ratio,fuel utilization ratio and anode gas recirculation.Second,product composition,especially methane content,is determined for the methanation process at the operating temperatures ranging from 500 ℃ to 520 ℃.Finally,the cooling power provided by internal reforming of methane in SOFC fuel channel is calculated for two concepts to increase the methane content of the diesel reformate.The results show that the first concept,operating the diesel reformer at low O/C ratio and/or recirculation ratio,is not realizable due to high probability of coke formation,whereas the second concept,combining a methanation process with CPOX,can provide a significant cooling effect in addition to the conventional cooling concept which needs higher levels of excess air.

  18. Numerical simulation on internal and external flow field of a SCAL indirect air cooling tower

    Institute of Scientific and Technical Information of China (English)

    TIAN Songfeng; CHAI Yanqin; XIANG Tongqiong; ZHOU Guangsha

    2014-01-01

    According to the actual size of cooling tube bundle and the arrangement of cooling triangle of a surface condenser aluminum exchangers (SCAL)natural draft cooling tower,the geometric model of heat transfer elements at the tower bottom was established.On the basis of the RNG k-εturbulence model and porous medium model,three-dimensional numerical simulation was carried out for the inner and external flow field of the air cooling tower,to investigate the influence of environmental conditions on the tower's operation performance.The results show that,with an increase in ambient wind speed,the inlet air speed at windward side of the tower increases gradually,while that at crosswind side and lee side decreases and tends to be obvious;the tower ventilation rate and outlet air speed increases at first and then decreases,and their maximum values appear when the wind speed is 2 m/s.

  19. Influence of the cooling degree upon performances of internal combustion engine

    Science.gov (United States)

    Grǎdinariu, Andrei Cristian; Mihai, Ioan

    2016-12-01

    Up to present, air cooling systems still raise several unsolved problems due to conditions imposed by the environment in terms of temperature and pollution levels. The present paper investigates the impact of the engine cooling degree upon its performances, as important specific power is desired for as low as possible fuel consumption. A technical solution advanced by the authors[1], consists of constructing a bi-flux compressor, which can enhance the engine's performances. The bi-flux axial compressor accomplishes two major functions, that is it cools down the engine and it also turbocharges it. The present paper investigates the temperature changes corresponding to the fresh load, during the use of a bi-flux axial compressor. This compressor is economically simple, compact, and offers an optimal response at low rotational speeds of the engine, when two compression steps are used. The influence of the relative coefficient of air temperature drop upon working agent temperature at the intercooler exit is also investigated in the present work. The variation of the thermal load coefficient by report to the working agent temperature is also investigated during engine cooling. The variation of the average combustion temperature is analyzed in correlation to the thermal load coefficient and the temperatures of the working fluid at its exit from the cooling system. An exergetic analysis was conducted upon the influence of the cooling degree on the motor fluid and the gases resulted from the combustion process.

  20. Composite germanium monochromators - results for the TriCS

    Energy Technology Data Exchange (ETDEWEB)

    Schefer, J.; Fischer, S.; Boehm, M.; Keller, L.; Horisberger, M.; Medarde, M.; Fischer, P. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Composite germanium monochromators are in the beginning of their application in neutron diffraction. We show here the importance of the permanent quality control with neutrons on the example of the 311 wafers which will be used on the single crystal diffractometer TriCS at SINQ. (author) 2 figs., 3 refs.

  1. Monochromator on a synchrotron undulator source for liquid surface studies

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Freund, A.K.

    1992-01-01

    a monochromator made of a beryllium mosaic crystal using the (002) reflection in Laue geometry placed in undulator beams of DORIS III at the Hamburger Synchrotronstrahlungslabor and of the European Synchrotron Radiation Facility. An analysis of the diffraction properties in terms of mosaic spread, heat load...

  2. Effect of the Cool System on Internal Stress of CaO-Al2O3-SiO2 Glass-ceramic System

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The samples were attained through altering the cooling system of producing glass-ceramics.The X-ray diffraction was used to test the stress value of different samples. The relation of the cooling system and internal stress were also investigated. The experimental results show that the stress of glass-ceramic had a close relation with starting cool temperature. Above 800 C, glass-ceramic could be accelerated cooling and did not bring stress. Temperature between 500 C and 800℃ was an important temperature range of the formation of stress in glass-ceramic, in which the glass-ceramic stress would change obviously. Cool system was the key on how to control and eliminate internal stress in order to reduce the destroy of materials crated by internal stress. In addition, glass particles size increase, glass-ceramic stress increase in consequent.

  3. Flow structure and heat exchange analysis in internal cooling channel of gas turbine blade

    Science.gov (United States)

    Szwaba, Ryszard; Kaczynski, Piotr; Doerffer, Piotr; Telega, Janusz

    2016-08-01

    This paper presents the study of the flow structure and heat transfer, and also their correlations on the four walls of a radial cooling passage model of a gas turbine blade. The investigations focus on heat transfer and aerodynamic measurements in the channel, which is an accurate representation of the configuration used in aeroengines. Correlations for the heat transfer coefficient and the pressure drop used in the design of radial cooling passages are often developed from simplified models. It is important to note that real engine passages do not have perfect rectangular cross sections, but include corner fillet, ribs with fillet radii and special orientation. Therefore, this work provides detailed fluid flow and heat transfer data for a model of radial cooling geometry which possesses very realistic features.

  4. Experimental and numerical study of near bleed hole heat transfer enhancement in internal turbine blade cooling channels

    CSIR Research Space (South Africa)

    Scheepers, G

    2006-01-01

    Full Text Available Conference on Computational and Applied Mechanics SACAM06 Cape Town, 16-18 January 2006 SACAM EXPERIMENTAL AND NUMERICAL STUDY OF NEAR BLEED HOLE HEAT TRANSFER ENHANCEMENT IN INTERNAL TURBINE BLADE COOLING CHANNELS Scheepers G*, Morris RM, Visser JA....5×104, while the hole suction ratio in terms of Reynolds number was varied from 0 to 5. 1. Introduction With the ever increasing demand for higher thermal efficiency, modern jet turbine blades are exposed to temperatures which comprehensively exceed...

  5. A vacuum ultraviolet filtering monochromator for synchrotron-based spectroscopy

    Science.gov (United States)

    Janik, Ireneusz; Marin, Timothy W.

    2013-01-01

    We describe the design, characterization, and implementation of a vacuum ultraviolet (VUV) monochromator for use in filtering stray and scattered light from the principal monochromator output of the Stainless Steel Seya VUV synchrotron beam line at the Synchrotron Radiation Center, University of Wisconsin-Madison. We demonstrate a reduction of three orders of magnitude of stray and scattered light over the wavelength range 1400-2000 Å with minimal loss of light intensity, allowing for over six orders of magnitude of dynamic range in light detection. We suggest that a similar filtering scheme can be utilized in any variety of spectroscopic applications where a large dynamic range and low amount of background signal are of import, such as in transmittance experiments with very high optical density.

  6. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, A. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Durschlag, H. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Elliott, D. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Hartsough, J. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Shukla, N. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Kosny, J. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States)

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  7. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, A. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Duraschlag, H. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Elliott, D. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Hartsough, J. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Shukla, N. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Kosny, J. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States)

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulk insulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosed reflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  8. Design and analysis of the internally cooled silicon mirrors and benders for wiggler sources at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Schildkamp, W.; Jaski, Y. [Consortium for Advanced Radiation Sources, University of Chicago, 5640 S. Ellis Ave., Chicago, IL 60637 (United States); Tonnessen, T.; Douglas, G. [Rocketdyne Albuquerque Operations, 2511 C. Broadbent Parkway, N.E., Albuquerque, NM 87107 (United States)

    1996-09-01

    When silicon single crystal mirrors are bent to cylindrical figures of typically 6 km bending radius, the moments needed are very small and easy to disturb by cooling attachments to the sides of the mirror. Hence, we decided to abandon the conventional concept of cooling plates attached to the sides of the mirrors and instead have chosen to use internal water channels. We present here the design of mirrors with cooling channels near the neutral axis of the silicon beam that have a rather thick {open_quote}{open_quote}hot wall.{close_quote}{close_quote} The results of this analytical work are nonintuitive, regarding the stresses produced by wiggler heating. The design path chosen minimizes figure errors due to coolant pressure variations and residual stresses from machining and bonding of multiple layers of silicon. The geometry of the water channels avoids water-to-vacuum seals and uses the mirror bender as the coolant manifold. Engineering efforts, which reduce the bending stresses at bender-to-silicon interface by a factor of five, will be presented. The complete mirror bender and motion control mechanics will be shown. {copyright} {ital 1996 American Institute of Physics.}

  9. Design and performance of the ALS double-crystal monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Jones, G.; Ryce, S.; Perera, R.C.C. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    A new {open_quotes}Cowan type{close_quotes} double-crystal monochromator, based on the boomerang design used at NSLS beamline X-24A, has been developed for beamline 9.3.1 at the ALS, a windowless UHV beamline covering the 1-6 keV photon-energy range. Beamline 9.3.1 is designed to simultaneously achieve the goals of high energy resolution, high flux, and high brightness at the sample. The mechanical design has been simplified, and recent developments in technology have been included. Measured mechanical precision of the monochromator shows significant improvement over existing designs. In tests with x-rays at NSLS beamline X-23 A2, maximum deviations in the intensity of monochromatic light were just 7% during scans of several hundred eV in the vicinity of the Cr K edge (6 keV) with the monochromator operating without intensity feedback. Such precision is essential because of the high brightness of the ALS radiation and the overall length of beamline 9.3.1 (26 m).

  10. Measurements and computational analysis of heat transfer and flow in a simulated turbine blade internal cooling passage

    Science.gov (United States)

    Russell, Louis M.; Thurman, Douglas R.; Simonyi, Patricia S.; Hippensteele, Steven A.; Poinsatte, Philip E.

    1993-01-01

    Visual and quantitative information was obtained on heat transfer and flow in a branched-duct test section that had several significant features of an internal cooling passage of a turbine blade. The objective of this study was to generate a set of experimental data that could be used to validate computer codes for internal cooling systems. Surface heat transfer coefficients and entrance flow conditions were measured at entrance Reynolds numbers of 45,000, 335,000, and 726,000. The heat transfer data were obtained using an Inconel heater sheet attached to the surface and coated with liquid crystals. Visual and quantitative flow field results using particle image velocimetry were also obtained for a plane at mid channel height for a Reynolds number of 45,000. The flow was seeded with polystyrene particles and illuminated by a laser light sheet. Computational results were determined for the same configurations and at matching Reynolds numbers; these surface heat transfer coefficients and flow velocities were computed with a commercially available code. The experimental and computational results were compared. Although some general trends did agree, there were inconsistencies in the temperature patterns as well as in the numerical results. These inconsistencies strongly suggest the need for further computational studies on complicated geometries such as the one studied.

  11. Theoretical modeling of RF ablation with internally cooled electrodes: comparative study of different thermal boundary conditions at the electrode-tissue interface.

    Science.gov (United States)

    Rivera, María J; Molina, Juan A López; Trujillo, Macarena; Berjano, Enrique J

    2009-07-01

    Previous studies on computer modeling of RF ablation with cooled electrodes modeled the internal cooling circuit by setting surface temperature at the coolant temperature (i.e., Dirichlet condition, DC). Our objective was to compare the temperature profiles computed from different thermal boundary conditions at the electrode-tissue interface. We built an analytical one-dimensional model based on a spherical electrode. Four cases were considered: A) DC with uniform initial condition, B) DC with pre-cooling period, C) Boundary condition based on Newton's cooling law (NC) with uniform initial condition, and D) NC with a pre-cooling period. The results showed that for a long time (120 s), the profiles obtained with (Cases B and D) and without (Cases A and C) considering pre-cooling are very similar. However, for shorter times ( 30 s), Cases A and C overestimated the temperature at points away from the electrode-tissue interface. In the NC cases, this overestimation was more evident for higher values of the convective heat transfer coefficient (h). Finally, with NC, when h was increased the temperature profiles became more similar to those with DC. The results suggest that theoretical modeling of RF ablation with cooled electrodes should consider: 1) the modeling of a pre-cooling period, especially if one is interested in the thermal profiles registered at the beginning of RF application; and 2) NC rather than DC, especially for low flow in the internal circuit.

  12. Porous nuclear fuel element with internal skeleton for high-temperature gas-cooled nuclear reactors

    Science.gov (United States)

    Youchison, Dennis L.; Williams, Brian E.; Benander, Robert E.

    2013-09-03

    Porous nuclear fuel elements for use in advanced high temperature gas-cooled nuclear reactors (HTGR's), and to processes for fabricating them. Advanced uranium bi-carbide, uranium tri-carbide and uranium carbonitride nuclear fuels can be used. These fuels have high melting temperatures, high thermal conductivity, and high resistance to erosion by hot hydrogen gas. Tri-carbide fuels, such as (U,Zr,Nb)C, can be fabricated using chemical vapor infiltration (CVI) to simultaneously deposit each of the three separate carbides, e.g., UC, ZrC, and NbC in a single CVI step. By using CVI, the nuclear fuel may be deposited inside of a highly porous skeletal structure made of, for example, reticulated vitreous carbon foam.

  13. Backscattering analyzer geometry as a straightforward and precise method for monochromator characterization at third-generation synchrotron-radiation sources (abstract)

    Science.gov (United States)

    Snigirev, A. A.; Lequien, S.; Suvorov, A. Yu.

    1995-02-01

    With the assessment of the third generation of synchrotron-radiation sources, insertion devices (ID) are going to become extensively used. The choice of the ID field configuration allows the optimization of the photon flux at the desired energy. This attractive situation results in a much higher flux on optical elements, mainly on monochromators for which new cooling schemes have to be developed. These latter must be characterized under operating conditions and generally, the figure of merit for monochromators is the rocking curve (RC) measurement. By varying the ID field, the monochromator may be fully characterized with regard to the heat load. To achieve this aim, we have proposed and tested a double-crystal setup where a Si analyzer crystal installed in backscattering geometry (BSG) is coupled with a silicon p-i-n photodiode as the detection system (Fig. 1). The analyzer was a standard Si wafer (111) orientation, from which we used the following Bragg reflections: 333, 444, 555, 777, 888, 999, ... to measure the RCs of monochromators keeping the analyzer fixed. We were then able to probe the formers at the respective energies 5.9, 7.9, 9.9, 13.8, 15.8, 17.8 keV, etc. Setting the analyzer crystal in BSG, we get several-fold benefits from the method: (1) A very good angular resolution (˜10-6 rad) when one combines the BSG analyzer with narrow slits (˜100 μm). (2) A high-energy resolution yielding to a calibration of the monochromator with an accuracy better than 1 eV. (3) The analyzer crystal attenuates the reflected intensity which avoids the use of any scatterer foil to count the number of photons. We directly used photodiodes which are well known to respond linearly to radiation intensities and to have a high dynamic range (more than 6 decades). (4) No fine mechanics is needed for the analyzer, just a simple manual turntable can be used to set the analyzer in BSG through the utilization of a laser beam. Results on different tests for operating liquid-N2

  14. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification.

    Science.gov (United States)

    Niu, Xiaofeng; Xu, Qing; Zhang, Yi; Zhang, Yue; Yan, Yufeng; Liu, Tao

    2017-04-29

    Micro-nanoencapsulated phase change materials (M-NEPCMs) are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate):Tween80 (polyoxyethylene sorbitan monooleate):Span80 (sorbitan monooleate) = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  15. Characterisation of a Sr-90 based electron monochromator

    CERN Document Server

    Arfaoui, S; CERN; Casella, C; ETH Zurich

    2015-01-01

    This note describes the characterisation of an energy filtered Sr-90 source to be used in laboratory studies that require Minimum Ionising Particles (MIP) with a kinetic energy of up to approx. 2 MeV. The energy calibration was performed with a LYSO scintillation crystal read out by a digital Silicon Photomultiplier (dSiPM). The LYSO/dSiPM set-up was pre-calibrated using a Na-22 source. After introducing the motivation behind the usage of such a device, this note presents the principle and design of the electron monochromator as well as its energy and momentum characterisation.

  16. Cooling of an internal-heated debris bed with fine particles

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z.L.; Sehgal, B.R. [Royal Institute of Technology, Div. of Nuclear Power Safety, Stockholm (Sweden)

    2001-07-01

    In this paper, an analytical model on dryout heat flux of ex-vessel debris beds with fines particles under top flooding conditions has been developed. The parametric study is performed on the effect of the stratification of the debris beds on the dryout heat flux. The calculated results show that the stratification configuration of the debris beds with smaller particles and lower porosity layer resting on the top of another layer of the beds has profound effect on the dryout heat flux for the debris beds both with and without a downcomer. The enhancement of the dryout heat flux by the downcomer is significant. The efficiency of the single downcomer on the enhancement of the dryout heat flux is also analyzed. This, in general, agrees well with experimental data. The model is also employed to perform the assessment on the coolability of the ex-vessel debris bed under representative accidental conditions. One conservative case is chosen, and it is found that the downcomer could be efficient measure to cool the debris bed and hence terminate the severe accident. (authors)

  17. Technical Consultation of the International Space Station (ISS) Internal Active Thermal Control System (IATCS) Cooling Water Chemistry

    Science.gov (United States)

    Gentz, Steven J.; Rotter, Hank A.; Easton, Myriam; Lince, Jeffrey; Park, Woonsup; Stewart, Thomas; Speckman, Donna; Dexter, Stephen; Kelly, Robert

    2005-01-01

    The Internal Active Thermal Control System (IATCS) coolant exhibited unexpected chemical changes during the first year of on-orbit operation following the launch and activation in February 2001. The coolant pH dropped from 9.3 to below the minimum specification limit of 9.0, and re-equilibrated between 8.3 and 8.5. This drop in coolant pH was shown to be the result of permeation of CO2 from the cabin into the coolant via Teflon flexible hoses which created carbonic acid in the fluid. This unexpected diffusion was the result of having a cabin CO2 partial pressure higher than the ground partial pressure (average 4.0 mmHg vs. less than 0.2 mmHg). This drop in pH was followed by a concurrent increasing coolant nickel concentration. No other metal ions were observed in the coolant and based on previous tests, the source of nickel ion was thought to be the boron nickel (BNi) braze intermetallics used in the construction of HXs and cold plates. Specifically, BNi2 braze alloy was used for the IATCS IFHX and BNi3 braze alloy was used for the IATCS Airlock Servicing and Performance Checkout Unit (SPCU) HX and cold plates. Given the failure criticality of the HXs, a Corrosion Team was established by the IATCS CWG to determine the impact of the nickel corrosion on hardware performance life.

  18. Effects of cooling and internal wave motions on gas transfer coefficients in a boreal lake

    Directory of Open Access Journals (Sweden)

    Jouni J. Heiskanen

    2014-05-01

    Full Text Available Lakes and other inland waters contribute significantly to regional and global carbon budgets. Emissions from lakes are often computed as the product of a gas transfer coefficient, k 600 , and the difference in concentration across the diffusive boundary layer at the air–water interface. Eddy covariance (EC techniques are increasingly being used in lacustrine gas flux studies and tend to report higher values for derived k 600 than other approaches. Using results from an EC study of a small, boreal lake, we modelled k 600 using a boundary-layer approach that included wind shear and cooling. During stratification, fluxes estimated by EC occasionally were higher than those obtained by our models. The high fluxes co-occurred with winds strong enough to induce deflections of the thermocline. We attribute the higher measured fluxes to upwelling-induced spatial variability in surface concentrations of CO2 within the EC footprint. We modelled the increased gas concentrations due to the upwelling and corrected our k 600 values using these higher CO2 concentrations. This approach led to greater congruence between measured and modelled k values during the stratified period. k 600 has a well-resolved and ~cubic relationship with wind speed when the water column is unstratified and the dissolved gases well mixed. During stratification and using the corrected k 600 , the same pattern is evident at higher winds, but k 600 has a median value of ~7 cm h−1 when winds are less than 6 m s−1, similar to observations in recent oceanographic studies. Our models for k 600 provide estimates of gas evasion at least 200% higher than earlier wind-based models. Our improved k 600 estimates emphasize the need for integrating within lake physics into models of greenhouse gas evasion.

  19. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

    DEFF Research Database (Denmark)

    Zhu, Diling; Feng, Yiping; Stoupin, Stanislav

    2014-01-01

    A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressu...

  20. Microcontroller-based servo for two-crystal X-ray monochromators.

    Science.gov (United States)

    Siddons, D P

    1998-05-01

    Microcontrollers have become increasingly easy to incorporate into instruments as the architectures and support tools have developed. The PIC series is particularly easy to use, and this paper describes a controller used to stabilize the output of a two-crystal X-ray monochromator at a given offset from its peak intensity position, as such monochromators are generally used.

  1. Structural Analysis of Helios Filament-Wound Tanks Subjected to Internal Pressure and Cooling

    Science.gov (United States)

    Ko, William L

    2005-01-01

    A finite-element stress analysis is performed on Helios filament-wound hydrogen tanks to examine the stress field and effect of end dome geometry on the stress field. Each tank is composed of a central circular cylindrical section with either geodesic or hemispherical end domes, which have metallic polar bosses. The tanks are subjected to combined and separate internal pressure and temperature loading conditions, and the stress contributions of each loading component are examined. The tank-wall-polar-boss interfacial meridional tensile stress in the hemispherical dome is found to be approximately 27 percent lower than that in the geodesic dome. The effects of both material anisotropy and the aluminum lining on the intensities of tensile meridional stress at the tank-wall-polar-boss bonding interface are examined.

  2. RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?

    Directory of Open Access Journals (Sweden)

    Cruz Ignacio

    2007-07-01

    Full Text Available Abstract Background Radiofrequency ablation (RFA of tumors by means of internally cooled electrodes (ICE combined with interstitial infusion of saline may improve clinical results. To date, infusion has been conducted through outlets placed on the surface of the cooled electrode. However, the effect of infusion at a distance from the electrode surface is unknown. Our aim was to assess the effect of perfusion distance (PD on the coagulation geometry and deposited power during RFA using ICE. Methods Experiments were performed on excised bovine livers. Perfusion distance (PD was defined as the shortest distance between the infusion outlet and the surface of the ICE. We considered three values of PD: 0, 2 and 4 mm. Two sets of experiments were considered: 1 15 ablations of 10 minutes (n ≥ 4 for each PD, in order to evaluate the effect of PD on volume and diameters of coagulation; and 2 20 additional ablations of 20 minutes. The effect of PD on deposited power and relative frequency of uncontrolled impedance rises (roll-off was evaluated using the results from the two sets of experiments (n ≥ 7 for each PD. Comparisons between PD were performed by analysis of variance or Kruskal-Wallis test. Additionally, non-linear regression models were performed to elucidate the best PD in terms of coagulation volume and diameter, and the occurrence of uncontrolled impedance rises. Results The best-fit least square functions were always obtained with quadratic curves where volume and diameters of coagulation were maximum for a PD of 2 mm. A thirty per cent increase in volume coagulation was observed for this PD value compared to other values (P Conclusion Saline perfusion at around 2 mm from the electrode surface while using an ICE in RFA improves deposition of energy and enlarges coagulation volume.

  3. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification

    Directory of Open Access Journals (Sweden)

    Xiaofeng Niu

    2017-04-01

    Full Text Available Micro-nanoencapsulated phase change materials (M-NEPCMs are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate:Tween80 (polyoxyethylene sorbitan monooleate:Span80 (sorbitan monooleate = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  4. Homogenization of the internal structures of a reactor with the cooling fluid

    Energy Technology Data Exchange (ETDEWEB)

    Robbe, M.F. [CEA Saclay, SEMT, 91 - Gif sur Yvette (France); Bliard, F. [Socotec Industrie, Service AME, 78 - Montigny le Bretonneux (France)

    2001-07-01

    To take into account the influence of a structure net among a fluid flow, without modelling exactly the structure shape, a concept of ''equivalent porosity method'' was developed. The structures are considered as solid pores inside the fluid. The structure presence is represented by three parameters: a porosity, a shape coefficient and a pressure loss coefficient. The method was studied for an Hypothetical Core Disruptive Accident in a Liquid Metal Fast Breeder Reactor, but it can be applied to any problem involving fluid flow getting through a solid net. The model was implemented in the computer code CASTEM-PLEXUS and validated on an analytical shock tube test, simulating an horizontal slice of a schematic LMFBR in case of a HCDA (bubble at high pressure, liquid sodium and internal structures of the reactor). A short parametric study shows the influence of the porosity and the structure shape on the pressure wave impacting the shock tube bottom. These results were used to simulate numerically the HCDA mechanical effects in a small scale reactor mock-up. (author)

  5. VARIAN加速器内循环水冷维修%Maintenance of Internal Circulation Water Cooling System of VARIAN Accelerator

    Institute of Scientific and Technical Information of China (English)

    逄宏义

    2012-01-01

    介绍了VARIAN(瓦里安)加速器内循环水冷系统的原理及故障维修。%Introduce the working principles and trouble shooting of the internal circulation water cooling system of VARIAN Accelerator.

  6. Double-crystal monochromator for a PF 60-period soft x-ray undulator (abstract)

    Science.gov (United States)

    Ishikawa, T.; Maezawa, H.; Nomura, M.; Ando, M.

    1989-07-01

    Since undulator light is sharply collimated itself, it can be effectively monochromatized by a perfect crystal. An x-ray double-crystal monochromator with a fixed exit has been designed and built for the use of undulator light from a 60-period undulator at Photon Factory (beamline 2A). Available Bragg angle ranges from 7° to 80°. Angle scan is made by means of a goniometer outside the vacuum chamber, with the finest step of 0.1 arcsec. Magnetic fluid is used as the vacuum seal of the feedthrough. The fixed exit beam position is kept by translating the second crystal along the two mechanical guides: one for normal and the other for parallel to the crystal surface. Adjustment of the parallelity of two crystals is made manually with flexible wires. Since a total power in the central coherent portion which is limited by a 1×1-mm2 slit is not so much, a stable operation is possible without cooling the crystal. Currently, InSb (111) reflection is used. The diffracting planes of the first cyrstal is 1° off from the surface and the second is the symmetric reflection. At its fifth harmonics, brilliant undulator light of approximately 1012 photons/s mm2 with 1-eV energy resolution is available (E=2 keV).

  7. MACS low-background doubly focusing neutron monochromator

    CERN Document Server

    Smee, S A; Scharfstein, G A; Qiu, Y; Brand, P C; Anand, D K; Broholm, C L

    2002-01-01

    A novel doubly focusing neutron monochromator has been developed as part of the Multi-Analyzer Crystal Spectrometer (MACS) at the NIST Center for Neutron Research. The instrument utilizes a unique vertical focusing element that enables active vertical and horizontal focusing with a large, 357-crystal (1428 cm sup 2), array. The design significantly reduces the amount of structural material in the beam path as compared to similar instruments. Optical measurements verify the excellent focal performance of the device. Analytical and Monte Carlo simulations predict that, when mounted at the NIST cold-neutron source, the device should produce a monochromatic beam (DELTA E=0.2 meV) with flux phi>10 sup 8 n/cm sup 2 s. (orig.)

  8. SUMS: synchronous undulator-monochromator scans at Synchrotron Soleil.

    Science.gov (United States)

    Izquierdo, Manuel; Hardion, Vincent; Renaud, Guillaume; Chapuis, Lilian; Millet, Raphael; Langlois, Florent; Marteau, Fabrice; Chauvet, Christian

    2012-07-01

    A strategy for performing synchronous undulator-monochromator scans (SUMS) compatible with the control system of Synchrotron Soleil has been developed. The implementation of the acquisition scheme has required the development of an electronic interface between the undulator and the beamline. The characterization of delays and jitters in the synchronous movement of various motor axes has motivated the development of a new electronic synchronization scheme among various axes, including the case when one of the axes is electronically accessible in `read-only' mode. A software prototype has been developed to allow the existing hard continuous software to work in user units. The complete strategy has been implemented and successfully tested at the TEMPO beamline.

  9. Monochromator-Based Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Hartmann, J.

    2011-08-01

    A monochromator integrating-sphere-based spectral comparator facility has been developed to calibrate standard radiation thermometers in terms of the absolute spectral radiance responsivity, traceable to the PTB cryogenic radiometer. The absolute responsivity calibration has been improved using a 75 W xenon lamp with a reflective mirror and imaging optics to a relative standard uncertainty at the peak wavelength of approximately 0.17 % ( k = 1). Via a relative measurement of the out-of-band responsivity, the spectral responsivity of radiation thermometers can be fully characterized. To verify the calibration accuracy, the absolutely calibrated radiation thermometer is used to measure Au and Cu freezing-point temperatures and then to compare the obtained results with the values obtained by absolute methods, resulting in T - T 90 values of +52 mK and -50 mK for the gold and copper fixed points, respectively.

  10. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  11. The development of a 200 kV monochromated field emission electron source

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Masaki, E-mail: mmukai@jeol.co.jp [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Kim, Judy S. [University of Oxford, Department of Materials, Parks Road, Oxford, OX1 3PH (United Kingdom); Omoto, Kazuya; Sawada, Hidetaka; Kimura, Atsushi; Ikeda, Akihiro; Zhou, Jun; Kaneyama, Toshikatsu [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Young, Neil P.; Warner, Jamie H.; Nellist, Peter D.; Kirkland, Angus I. [University of Oxford, Department of Materials, Parks Road, Oxford, OX1 3PH (United Kingdom)

    2014-05-01

    We report the development of a monochromator for an intermediate-voltage aberration-corrected electron microscope suitable for operation in both STEM and TEM imaging modes. The monochromator consists of two Wien filters with a variable energy selecting slit located between them and is located prior to the accelerator. The second filter cancels the energy dispersion produced by the first filter and after energy selection forms a round monochromated, achromatic probe at the specimen plane. The ultimate achievable energy resolution has been measured as 36 meV at 200 kV and 26 meV at 80 kV. High-resolution Annular Dark Field STEM images recorded using a monochromated probe resolve Si–Si spacings of 135.8 pm using energy spreads of 218 meV at 200 kV and 217 meV at 80 kV respectively. In TEM mode an improvement in non-linear spatial resolution to 64 pm due to the reduction in the effects of partial temporal coherence has been demonstrated using broad beam illumination with an energy spread of 134 meV at 200 kV. - Highlights: • Monochromator for 200 kV aberration corrected TEM and STEM was developed. • Monochromator produces monochromated and achromatic probe at specimen plane. • Ultimate energy resolution was measured to be 36 meV at 200 kV and 26 meV at 80 kV. • Atomic resolution STEM images were recorded using monochromated electron probe. • Improvements of TEM resolution were confirmed using monochromated illumination.

  12. Optimization of Monochromated TEM for Ultimate Resolution Imaging and Ultrahigh Resolution Electron Energy Loss Spectroscopy

    KAUST Repository

    Lopatin, Sergei

    2017-09-01

    The performance of a monochromated transmission electron microscope with Wien type monochromator is optimized to achieve an extremely narrow energy spread of electron beam and an ultrahigh energy resolution with spectroscopy. The energy spread in the beam is improved by almost an order of magnitude as compared to specified values. The optimization involves both the monochromator and the electron energy loss detection system. We demonstrate boosted capability of optimized systems with respect to ultra-low loss EELS and sub-angstrom resolution imaging (in a combination with spherical aberration correction).

  13. Thermal study of the structure of an internal combustion engine and assessment of cooling system efficiency by a numerical tridimensional simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lagasse, J.P.; Rossi, F.N. (Regie Nationale des Usines Renault 92 - Boulogne (FR))

    1989-01-01

    This paper proposes a calculation tool to evaluate the thermal field of the structure of an internal combustion engine. For this purpose a calculation procedure has been devised to take into account the thermal exchanges with the cooling fluid, the gases taking part to the combustion, the exchanges with the environment under the hood, the lubrificating liquid. The particularity of our study is to model with precision the action of the cooling fluid by solving the tridimensional thermo-hydraulic problem. This enables to evaluate quantitatively the efficiency of the cooling system and the influence of some geometrical modifications. We discuss the case of the housing of a car diesel-engine in using simultaneously an industrial thermo-hydraulic finite elements software (developed by C.E.A.) and a combustion specific one-dimensional software.

  14. The Effect of Using a Modified A/C System on the Cooling System Temperature of an Internal Combustion Engine

    Directory of Open Access Journals (Sweden)

    Mukhtar M.A. Morad

    2017-05-01

    Full Text Available This study investigates the effect of using A/C refrigerant to reduce the temperature of the coolant in a vehicle cooling system. An increase in coolant temperature due to harsh working conditions increases fuel consumption and leads to a reduction in engine power. Modifying vehicle air-conditioning by passing the suction line of the A/C system through the heat exchanger located in the lower part of the radiator (down flow type can significantly improve the performance of the engine cooling system. The results show a reduction in the temperature of coolant within the cooling system, thus maintaining a controlled working temperature within the allowable limits

  15. Aberration corrected and monochromated environmental transmission electron microscopy: challenges and prospects for materials science

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal; Dunin-Borkowski, Rafal E.

    2010-01-01

    The latest generation of environmental transmission electron microscopes incorporates aberration correctors and monochromators, allowing studies of chemical reactions and growth processes with improved spatial resolution and spectral sensitivity. Here, we describe the performance of such an instr......The latest generation of environmental transmission electron microscopes incorporates aberration correctors and monochromators, allowing studies of chemical reactions and growth processes with improved spatial resolution and spectral sensitivity. Here, we describe the performance...

  16. IMCA-CAT BM first monochromator crystal optimization

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, I.N.; Cimpoes, S.; Chrzas, J. [CSRRI, Illinois Institute of Technology, 3301 S. Dearborn Street, Chicago, Il 60616 (United States)

    1996-09-01

    The high heat load at the surfaces of the first x-ray optical elements at the APS requires special measures to be taken to more completely utilize the beam. A conceptually new design for such an element, proposed, realized, and tested by M. Hart and conveniently called {open_quote}{open_quote}matchbox,{close_quote}{close_quote} is to be implemented at the IMCA-CAT BM beamline as the first monochromator crystal. The requirements of the IMCA-CAT companies for the BM beamline dictate that an optimization of the design is made for a given x-ray energy range E=13 keV {plus_minus}1 keV. A modification of the original design to improve the vacuum compatibility of the device was made in collaboration with M. Hart. A FEA optimization of the geometry is made using the ALGOR and ABAQUS programs. Determination of the resulting slopes and the useful crystal surface after the best compensation of the thermal distortions are also made. The surface profile obtained by the FEA study was used to perform a ray-tracing analysis of the IMCA-CAT BM beamline. The results of the ray-tracing study will be presented. {copyright} {ital 1996 American Institute of Physics.}

  17. Moessbauer-Fresnel zone plate as nuclear monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Mooney, T.M.; Alp, E.E.; Yun, W.B.

    1992-06-01

    Zone plates currently used in x-ray optics derive their focusing power from (a spatial variation of) the electronic refractive index -- that is, from the collective effect of electronic x-ray-scattering amplitudes. Nuclei also scatter x rays, and resonant nuclear-scattering amplitudes, particularly those associated with Moessbauer fluorescence, can dominate the refractive index for x-rays whose energies are very near the nuclear-resonance energy. A zone plate whose Fresnel zones are filled alternately with {sup 57}Fe and {sup 56}Fe ({sup 57}Fe has a nuclear resonance of natural width {Gamma} = 4.8 nano-eV at 14.413 keV; {sup 56}Fe has no such resonance) has a resonant focusing efficiency; it focuses only those x-rays whose energies are within several {Gamma} of resonance. When followed by an absorbing screen with a small pinhole, such a zone plate can function as a synchrotron-radiation monochromator with an energy resolution of a few parts in 10{sup 12}. The energy-dependent focusing efficiency and the resulting time-dependent response of a resonant zone plate are discussed.

  18. Liquid-crystal displays for medical imaging: a discussion of monochrome versus color

    Science.gov (United States)

    Wright, Steven L.; Samei, Ehsan

    2004-05-01

    A common view is that color displays cannot match the performance of monochrome displays, normally used for diagnostic x-ray imaging. This view is based largely on historical experience with cathode-ray tube (CRT) displays, and does not apply in the same way to liquid-crystal displays (LCDs). Recent advances in color LCD technology have considerably narrowed performance differences with monochrome LCDs for medical applications. The most significant performance advantage of monochrome LCDs is higher luminance, a concern for use under bright ambient conditions. LCD luminance is limited primarily by backlight design, yet to be optimized for color LCDs for medical applications. Monochrome LCDs have inherently higher contrast than color LCDs, but this is not a major advantage under most conditions. There is no practical difference in luminance precision between color and monochrome LCDs, with a slight theoretical advantage for color. Color LCDs can provide visualization and productivity enhancement for medical applications, using digital drive from standard commercial graphics cards. The desktop computer market for color LCDs far exceeds the medical monitor market, with an economy of scale. The performance-to-price ratio for color LCDs is much higher than monochrome, and warrants re-evaluation for medical applications.

  19. The cryogenic cooling program in high-heat-load optics at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, C.S.

    1993-07-01

    This paper describes some of the aspects of the cryogenic optics program at the Advanced Photon Source (APS). A liquid-nitrogen-cooled, high-vacuum, double crystal monochromator is being fabricated at Argonne National Laboratory (ANL). A pumping system capable of delivering a variable flow rate of up to 10 gallons per minute of pressurized liquid nitrogen and removing 5 kilowatts of x-ray power is also being constructed. This specialized pumping system and monochromator will be used to test the viability of cryogenically cooled, high-heat-load synchrotron optics. It has been determined that heat transfer enhancement will be required for optics used with APS insertion devices. An analysis of a porous-matrix-enhanced monochromator crystal is presented. For the particular case investigated, a heat transfer enhancement factor of 5 to 6 was calculated.

  20. Reuse of Treated Internal or External Wastewaters in the Cooling Systems of Coal-Based Thermoelectric Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Radisav Vidic; David Dzombak; Ming-Kai Hsieh; Heng Li; Shih-Hsiang Chien; Yinghua Feng; Indranil Chowdhury; Jason Monnell

    2009-06-30

    This study evaluated the feasibility of using three impaired waters - secondary treated municipal wastewater, passively treated abandoned mine drainage (AMD), and effluent from ash sedimentation ponds at power plants - for use as makeup water in recirculating cooling water systems at thermoelectric power plants. The evaluation included assessment of water availability based on proximity and relevant regulations as well as feasibility of managing cooling water quality with traditional chemical management schemes. Options for chemical treatment to prevent corrosion, scaling, and biofouling were identified through review of current practices, and were tested at bench and pilot-scale. Secondary treated wastewater is the most widely available impaired water that can serve as a reliable source of cooling water makeup. There are no federal regulations specifically related to impaired water reuse but a number of states have introduced regulations with primary focus on water aerosol 'drift' emitted from cooling towers, which has the potential to contain elevated concentrations of chemicals and microorganisms and may pose health risk to the public. It was determined that corrosion, scaling, and biofouling can be controlled adequately in cooling systems using secondary treated municipal wastewater at 4-6 cycles of concentration. The high concentration of dissolved solids in treated AMD rendered difficulties in scaling inhibition and requires more comprehensive pretreatment and scaling controls. Addition of appropriate chemicals can adequately control corrosion, scaling and biological growth in ash transport water, which typically has the best water quality among the three waters evaluated in this study. The high TDS in the blowdown from pilot-scale testing units with both passively treated mine drainage and secondary treated municipal wastewater and the high sulfate concentration in the mine drainage blowdown water were identified as the main challenges for blowdown

  1. Double crystal monochromator controlled by integrated computing on BL07A in New SUBARU, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Okui, Masato, E-mail: okui@kohzu.co.jp [Kohzu Precision Co., Ltd., 2-6-15, Kurigi, Asao-ku, Kawasaki-shi, Kanagawa 215-8521 (Japan); Laboratory of Advanced Science and Technology for Industry, University of Hyogo (Japan); Yato, Naoki; Watanabe, Akinobu; Lin, Baiming; Murayama, Norio [Kohzu Precision Co., Ltd., 2-6-15, Kurigi, Asao-ku, Kawasaki-shi, Kanagawa 215-8521 (Japan); Fukushima, Sei, E-mail: FUKUSHIMA.Sei@nims.go.jp [Laboratory of Advanced Science and Technology for Industry, University of Hyogo (Japan); National Institute for Material Sciences (Japan); Kanda, Kazuhiro [Laboratory of Advanced Science and Technology for Industry, University of Hyogo (Japan)

    2016-07-27

    The BL07A beamline in New SUBARU, University of Hyogo, has been used for many studies of new materials. A new double crystal monochromator controlled by integrated computing was designed and installed in the beamline in 2014. In this report we will discuss the unique features of this new monochromator, MKZ-7NS. This monochromator was not designed exclusively for use in BL07A; on the contrary, it was designed to be installed at low cost in various beamlines to facilitate the industrial applications of medium-scale synchrotron radiation facilities. Thus, the design of the monochromator utilized common packages that can satisfy the wide variety of specifications required at different synchrotron radiation facilities. This monochromator can be easily optimized for any beamline due to the fact that a few control parameters can be suitably customized. The beam offset can be fixed precisely even if one of the two slave axes is omitted. This design reduces the convolution of mechanical errors. Moreover, the monochromator’s control mechanism is very compact, making it possible to reduce the size of the vacuum chamber can be made smaller.

  2. Cascade self-seeding scheme with wake monochromator for narrow-bandwidth X-ray FELs

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni

    2010-01-01

    Three different approaches have been proposed so far for production of highly monochromatic X-rays from a baseline XFEL undulator: (i) single-bunch self-seeding scheme with a four crystal monochromator in Bragg reflection geometry; (ii) double-bunch self-seeding scheme with a four-crystal monochromator in Bragg reflection geometry; (iii) single-bunch self-seeding scheme with a wake monochromator. A unique element of the X-ray optical design of the last scheme is the monochromatization of X-rays using a single crystal in Bragg-transmission geometry. A great advantage of this method is that the monochromator introduces no path delay of X-rays. This fact eliminates the need for a long electron beam bypass, or for the creation of two precisely separated, identical electron bunches, as required in the other two self-seeding schemes. In its simplest configuration, the self-seeded XFEL consists of an input undulator and an output undulator separated by a monochromator. In some experimental situations this simplest t...

  3. The residual stress instrument with optimized Si(220) monochromator and position-sensitive detector at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang-Hee [Korea Atomic Energy Research Institute, Yusung, Daejon 305-600 (Korea, Republic of); Moon, Myung-Kook [Korea Atomic Energy Research Institute, Yusung, Daejon 305-600 (Korea, Republic of)]. E-mail: moonmk@kaeri.re.kr; Em, Vyacheslav T. [Korea Atomic Energy Research Institute, Yusung, Daejon 305-600 (Korea, Republic of); Choi, Young-Hyun [Korea Atomic Energy Research Institute, Yusung, Daejon 305-600 (Korea, Republic of); Cheon, Jong-Kyu [Korea Atomic Energy Research Institute, Yusung, Daejon 305-600 (Korea, Republic of); Nam, Uk-Won [Korea Astronomy Observatory, Yusung, Daejon 305-348 (Korea, Republic of); Kong, Kyung-Nam [Korea Astronomy Observatory, Yusung, Daejon 305-348 (Korea, Republic of)

    2005-06-11

    An upgraded residual stress instrument at the HANARO reactor of the KAERI is described. A horizontally focusing bent perfect crystal Si(220) monochromator (instead of a mosaic vertical focusing Ge monochromator) is installed in a drum with a tunable (2{theta}{sub M}=0-60{sup o}) take-off angle/wavelength. A specially designed position-sensitive detector (60% efficiency for {lambda}=1.8A) with 200mm (instead of 100mm) high-active area is used. There are no Soller type collimators in the instrument. The minimum possible monochromator to sample distance, L{sub MS}=2m, and sample to detector distance, L{sub SD}=1.2m, were found to be optimal. The new PSD and bent Si(220) monochromator combined with the possibility of selecting an appropriate wavelength resulted in about a ten-fold gain in data collection rate. The optimal reflections of austenitic and ferritic steels, aluminum and nickel for stress measurements with a Si(220) monochromator were chosen experimentally. The ability of the instrument to make strain measurements deep inside the austenitic and ferritic steels has been tested. For the chosen reflections and wavelengths, no shift of peak position (apparent strain) was observed up to 56mm length of path.

  4. A double multilayer monochromator for the B16 Test beamline at the Diamond Light Source

    Science.gov (United States)

    Sawhney, K. J. S.; Dolbnya, I. P.; Scott, S. M.; Tiwari, M. K.; Preece, G. M.; Alcock, S. G.; Malandain, A. W.

    2011-09-01

    The B16 Test beamline at the Diamond Light Source is in user operation. It has been recently upgraded with the addition of a double multilayer monochromator (DMM), which provides further functionality and versatility to the beamline. The multilayer monochromator is equipped with two pairs of multilayer optics (Ni/B4C and Ru/B4C) to cover the wide photon energy range of 2 - 20 keV, with good efficiency. The DMM provides a broad bandpass / high flux operational mode for the beamline and, when used in tandem with the Si (111) double crystal monochromator, it gives a very high higher-order harmonics suppression. The design details of the DMM and the first commissioning results obtained using the DMM are presented.

  5. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

    OpenAIRE

    Zhu, Diling; Feng, Yiping; Stoupin, Stanislav; Terentyev, Sergey A.; Lemke, Henrik T.; Fritz, David M.; Chollet, Matthieu; Glownia, J. M.; Alonso-Mori, Roberto; Sikorski, Marcin; Song, Sanghoon; Brandt van Driel, Tim; Williams, Garth J; Messerschmidt, Marc; Boutet, Sébastien

    2014-01-01

    A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transm...

  6. Comparison of Color LCD and Medical-grade Monochrome LCD Displays in Diagnostic Radiology

    OpenAIRE

    2007-01-01

    In diagnostic radiology, medical-grade monochrome displays are usually recommended because of their higher luminance. Standard color displays can be used as a less expensive alternative, but have a lower luminance. The aim of the present study was to compare image quality for these two types of displays. Images of a CDRAD contrast-detail phantom were read by four radiologists using a 2-megapixel (MP) color display (143 cd/m2 maximum luminance) as well as 2-MP (295 cd/m2) and 3-MP monochrome d...

  7. A diffracted-beam monochromator for long linear detectors in X-ray diffractometers with Bragg-Brentano parafocusing geometry

    NARCIS (Netherlands)

    Van der Pers, N.M.; Hendrikx, R.W.A.; Delhez, R.; Böttger, A.J.

    2013-01-01

    A new diffracted-beam monochromator has been developed for Bragg-Brentano X-ray diffractometers equipped with a linear detector. The monochromator consists of a cone-shaped graphite highly oriented pyrolytic graphite crystal oriented out of the equatorial plane such that the parafocusing geometry is

  8. Microtextured Surfaces for Turbine Blade Impingement Cooling

    Science.gov (United States)

    Fryer, Jack

    2014-01-01

    Gas turbine engine technology is constantly challenged to operate at higher combustor outlet temperatures. In a modern gas turbine engine, these temperatures can exceed the blade and disk material limits by 600 F or more, necessitating both internal and film cooling schemes in addition to the use of thermal barrier coatings. Internal convective cooling is inadequate in many blade locations, and both internal and film cooling approaches can lead to significant performance penalties in the engine. Micro Cooling Concepts, Inc., has developed a turbine blade cooling concept that provides enhanced internal impingement cooling effectiveness via the use of microstructured impingement surfaces. These surfaces significantly increase the cooling capability of the impinging flow, as compared to a conventional untextured surface. This approach can be combined with microchannel cooling and external film cooling to tailor the cooling capability per the external heating profile. The cooling system then can be optimized to minimize impact on engine performance.

  9. Nanoscale mapping of optical band gaps using monochromated electron energy loss spectroscopy

    Science.gov (United States)

    Zhan, W.; Granerød, C. S.; Venkatachalapathy, V.; Johansen, K. M. H.; Jensen, I. J. T.; Kuznetsov, A. Yu; Prytz, Ø.

    2017-03-01

    Using monochromated electron energy loss spectroscopy in a probe-corrected scanning transmission electron microscope we demonstrate band gap mapping in ZnO/ZnCdO thin films with a spatial resolution below 10 nm and spectral precision of 20 meV.

  10. Measurement & Minimization of Mount Induced Strain on Double Crystal Monochromator Crystals

    Science.gov (United States)

    Kelly, J.; Alcock, S. G.

    2013-03-01

    Opto-mechanical mounts can cause significant distortions to monochromator crystals and mirrors if not designed or implemented carefully. A slope measuring profiler, the Diamond-NOM [1], was used to measure the change in tangential slope as a function of crystal clamping configuration and load. A three point mount was found to exhibit the lowest surface distortion (Diamond Light Source.

  11. Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology.

    Science.gov (United States)

    Geijer, Håkan; Geijer, Mats; Forsberg, Lillemor; Kheddache, Susanne; Sund, Patrik

    2007-06-01

    In diagnostic radiology, medical-grade monochrome displays are usually recommended because of their higher luminance. Standard color displays can be used as a less expensive alternative, but have a lower luminance. The aim of the present study was to compare image quality for these two types of displays. Images of a CDRAD contrast-detail phantom were read by four radiologists using a 2-megapixel (MP) color display (143 cd/m(2) maximum luminance) as well as 2-MP (295 cd/m(2)) and 3-MP monochrome displays. Thirty lumbar spine radiographs were also read by four radiologists using the color and the 2-MP monochrome display in a visual grading analysis (VGA). Very small differences were found between the displays when reading the CDRAD images. The VGA scores were -0.28 for the color and -0.25 for the monochrome display (p = 0.24; NS). It thus seems possible to use color displays in diagnostic radiology provided that grayscale adjustment is used.

  12. Electron cooling

    Science.gov (United States)

    Meshkov, I.; Sidorin, A.

    2004-10-01

    The brief review of the most significant and interesting achievements in electron cooling method, which took place during last two years, is presented. The description of the electron cooling facilities-storage rings and traps being in operation or under development-is given. The applications of the electron cooling method are considered. The following modern fields of the method development are discussed: crystalline beam formation, expansion into middle and high energy electron cooling (the Fermilab Recycler Electron Cooler, the BNL cooler-recuperator, cooling with circulating electron beam, the GSI project), electron cooling in traps, antihydrogen generation, electron cooling of positrons (the LEPTA project).

  13. Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M.

    2011-01-01

    Stochastic Cooling was invented by Simon van der Meer and was demonstrated at the CERN ISR and ICE (Initial Cooling Experiment). Operational systems were developed at Fermilab and CERN. A complete theory of cooling of unbunched beams was developed, and was applied at CERN and Fermilab. Several new and existing rings employ coasting beam cooling. Bunched beam cooling was demonstrated in ICE and has been observed in several rings designed for coasting beam cooling. High energy bunched beams have proven more difficult. Signal suppression was achieved in the Tevatron, though operational cooling was not pursued at Fermilab. Longitudinal cooling was achieved in the RHIC collider. More recently a vertical cooling system in RHIC cooled both transverse dimensions via betatron coupling.

  14. Self-seeding scheme with gas monochromator for narrow-bandwidth soft X-ray FELs

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-03-15

    Self-seeding schemes, consisting of two undulators with a monochromator in between, aim at reducing the bandwidth of SASE X-ray FELs. We recently proposed to use a new method of monochromatization exploiting a single crystal in Bragg transmission geometry for self-seeding in the hard X-ray range. Here we consider a possible extension of this method to the soft X-ray range using a cell filled with resonantly absorbing gas as monochromator. The transmittance spectrum in the gas exhibits an absorbing resonance with narrow bandwidth. Then, similarly to the hard X-ray case, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. In fact, the FEL pulse forces the gas atoms to oscillate in a way consistent with a forward-propagating, monochromatic radiation beam. The radiation power within this wake is much larger than the equivalent shot noise power in the electron bunch. Further on, the monochromatic wake of the radiation pulse is combined with the delayed electron bunch and amplified in the second undulator. The proposed setup is extremely simple, and composed of as few as two simple elements. These are the gas cell, to be filled with noble gas, and a short magnetic chicane. The installation of the magnetic chicane does not perturb the undulator focusing system and does not interfere with the baseline mode of operation. In this paper we assess the features of gas monochromator based on the use of He and Ne.We analyze the processes in the monochromator gas cell and outside it, touching upon the performance of the differential pumping system as well. We study the feasibility of using the proposed self-seeding technique to generate narrow bandwidth soft X-ray radiation in the LCLS-II soft X-ray beam line. We present conceptual design, technical implementation and expected performances of the gas monochromator self-seeding scheme. (orig.)

  15. Three dimensional simulation of nucleate boiling heat and mass transfer in cooling passages of internal combustion engines

    Science.gov (United States)

    Mehdipour, R.; Baniamerian, Z.; Delauré, Y.

    2016-05-01

    An accurate knowledge of heat transfer and temperature distribution in vehicle engines is essential to have a good management of heat transfer performance in combustion engines. This may be achieved by numerical simulation of flow through the engine cooling passages; but the task becomes particularly challenging when boiling occurs. Neglecting two phase flow processes in the simulation would however result in significant inaccuracy in the predictions. In this study a three dimensional numerical model is proposed using Fluent 6.3 to simulate heat transfer of fluid flowing through channels of conventional size. Results of the present theoretical and numerical model are then compared with some empirical results. For high fluid flow velocities, departure between experimental and numerical results is about 9 %, while for lower velocity conditions, the model inaccuracy increases to 18 %. One of the outstanding capabilities of the present model, beside its ability to simulate two phase fluid flow and heat transfer in three dimensions, is the prediction of the location of bubble formation and condensation which can be a key issue in the evaluation of the engine performance and thermal stresses.

  16. Effects of Rotation at Different Channel Orientations on the Flow Field inside a Trailing Edge Internal Cooling Channel

    Directory of Open Access Journals (Sweden)

    Matteo Pascotto

    2013-01-01

    Full Text Available The flow field inside a cooling channel for the trailing edge of gas turbine blades has been numerically investigated with the aim to highlight the effects of channel rotation and orientation. A commercial 3D RANS solver including a SST turbulence model has been used to compute the isothermal steady air flow inside both static and rotating passages. Simulations were performed at a Reynolds number equal to 20000, a rotation number (Ro of 0, 0.23, and 0.46, and channel orientations of γ=0∘, 22.5°, and 45°, extending previous results towards new engine-like working conditions. The numerical results have been carefully validated against experimental data obtained by the same authors for conditions γ=0∘ and Ro = 0, 0.23. Rotation effects are shown to alter significantly the flow field inside both inlet and trailing edge regions. These effects are attenuated by an increase of the channel orientation from γ=0∘ to 45°.

  17. Design and optimization of the grating monochromator for soft X-ray self-seeding FELs

    Energy Technology Data Exchange (ETDEWEB)

    Serkez, Svitozar

    2015-10-15

    The emergence of Free Electron Lasers (FEL) as a fourth generation of light sources is a breakthrough. FELs operating in the X-ray range (XFEL) allow one to carry out completely new experiments that probably most of the natural sciences would benefit. Self-amplified spontaneous emission (SASE) is the baseline FEL operation mode: the radiation pulse starts as a spontaneous emission from the electron bunch and is being amplified during an FEL process until it reaches saturation. The SASE FEL radiation usually has poor properties in terms of a spectral bandwidth or, on the other side, longitudinal coherence. Self-seeding is a promising approach to narrow the SASE bandwidth of XFELs significantly in order to produce nearly transformlimited pulses. It is achieved by the radiation pulse monochromatization in the middle of an FEL amplification process. Following the successful demonstration of the self-seeding setup in the hard X-ray range at the LCLS, there is a need for a self-seeding extension into the soft X-ray range. Here a numerical method to simulate the soft X-ray self seeding (SXRSS) monochromator performance is presented. It allows one to perform start-to-end self-seeded FEL simulations along with (in our case) GENESIS simulation code. Based on this method, the performance of the LCLS self-seeded operation was simulated showing a good agreement with an experiment. Also the SXRSS monochromator design developed in SLAC was adapted for the SASE3 type undulator beamline at the European XFEL. The optical system was studied using Gaussian beam optics, wave optics propagation method and ray tracing to evaluate the performance of the monochromator itself. Wave optics analysis takes into account the actual beam wavefront of the radiation from the coherent FEL source, third order aberrations and height errors from each optical element. The monochromator design is based on a toroidal VLS grating working at a fixed incidence angle mounting without both entrance and exit

  18. Incomplete cooling down of Saturn's A ring at solar equinox: Implication for seasonal thermal inertia and internal structure of ring particles

    CERN Document Server

    Morishima, Ryuji; Brooks, Shawn; Deau, Estelle; Pilorz, Stu

    2015-01-01

    At the solar equinox in August 2009, the Composite Infrared Spectrometer (CIRS) onboard Cassini showed the lowest Saturn's ring temperatures ever observed. Detailed radiative transfer models show that the observed equinox temperatures of Saturn's A ring are much higher than model predictions as long as only the flux from Saturn is taken into account. This indicates that the A ring was not completely cooled down at the equinox. We develop a simple seasonal model for ring temperatures and first assume that the internal density and the thermal inertia of a ring particle are uniform with depth. The particle size is estimated to be 1-2 m. The seasonal thermal inertia is found to be 30-50 Jm$^{-2}$K$^{-1}$s$^{-1/2}$ in the middle A ring whereas it is $\\sim$ 10 Jm$^{-2}$K$^{-1}$s$^{-1/2}$ or as low as the diurnal thermal inertia in the inner and outermost regions of the A ring. An additional internal structure model, in which a particle has a high density core surrounded by a fluffy regolith mantle, shows that the c...

  19. A magnetically adsorbed fine adjustment mechanism of the second crystal in a double-crystal monochromator

    Institute of Scientific and Technical Information of China (English)

    CAO Chong-Zhen; GAO Xue-Guan; MA Pei-Sun; WANG Feng-Qin; HE Dong-Qing; HUANG Yu-Ying; LIU Peng

    2005-01-01

    In a fine adjustment mechanism of the second crystal in a double-crystal monochromator, a compression spring is usually used as a return force element, but it often produces permanent deform after some time. A novel fine adjustment mechanism is put forward, which utilizes permanent-magnet as the return force element instead of a compression spring. Its principle and advantages of adjusting the pitch angle and the roll angle are analyzed, and the structure parameters of the permanent-magnet, which is the key pa rt of the fine adjustment mechanism, are optimized. The magnetically adsorbed fine adjustment mechanism has been testified and applied successfully in the double-crystal monochromator of 4W1B beam line in Beijing Synchrotron Radiation Facility (BSRF).

  20. Stress mitigation of x-ray beamline monochromators using topography test unit.

    Energy Technology Data Exchange (ETDEWEB)

    Maj, J.; Waldschmidt, G.; Baldo, P.; Macrander, A.; Koshelev, I.; Huang, R.; Maj, L.; Maj, A.; Univ. of Chicago; Northeastern Ohio Univ. Coll. of Medicine; Rosalind Franklin Univ. of Medicine and Science

    2007-01-01

    Silicon and diamond monochromators (crystals), often used in the Advanced Photon Source X-ray beamlines, require a good quality surface finish and stress-free installation to ensure optimal performance. The device used to mount the crystal has been shown to be ajor contributing source of stress. In this case, an adjustable mounting device is an effective method of reducing stresses and improve the rocking curve to levels much closer to ideal. Analysis by a topography test unit has been used to determine the distribution of stresses and to measure the rocking curve, as well as create CCD images of the crystal. This paper describes the process of measuring these stresses and manipulating the mounting device and crystal to create a substantially improved monochromator.

  1. Alignment and characterization of the two-stage time delay compensating XUV monochromator

    CERN Document Server

    Eckstein, Martin; Kubin, Markus; Yang, Chung-Hsin; Frassetto, Fabio; Poletto, Luca; Vrakking, Marc J J; Kornilov, Oleg

    2016-01-01

    We present the design, implementation and alignment procedure for a two-stage time delay compensating monochromator. The setup spectrally filters the radiation of a high-order harmonic generation source providing wavelength-selected XUV pulses with a bandwidth of 300 to 600~meV in the photon energy range of 3 to 50~eV. XUV pulses as short as $12\\pm3$~fs are demonstrated. Transmission of the 400~nm (3.1~eV) light facilitates precise alignment of the monochromator. This alignment strategy together with the stable mechanical design of the motorized beamline components enables us to automatically scan the XUV photon energ in pump-probe experiments that require XUV beam pointing stability. The performance of the beamline is demonstrated by the generation of IR-assisted sidebands in XUV photoionization of argon atoms.

  2. Grating monochromator for soft X-ray self-seeding the European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Serkez, Svitozar; Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany)

    2013-02-15

    Self-seeding is a promising approach to significantly narrow the SASE bandwidth of XFELs to produce nearly transform-limited pulses. The implementation of this method in the soft X-ray wavelength range necessarily involves gratings as dispersive elements. We study a very compact self-seeding scheme with a grating monochromator originally designed at SLAC, which can be straightforwardly installed in the SASE3 type undulator beamline at the European XFEL. The monochromator design is based on a toroidal VLS grating working at a fixed incidence angle mounting without entrance slit. It covers the spectral range from 300 eV to 1000 eV. The optical system was studied using wave optics method (in comparison with ray tracing) to evaluate the performance of the self-seeding scheme. Our wave optics analysis takes into account the actual beam wavefront of the radiation from the coherent FEL source, third order aberrations, and errors from each optical element. Wave optics is the only method available, in combination with FEL simulations, for the design of a self-seeding monochromator without exit slit. We show that, without exit slit, the self-seeding scheme is distinguished by the much needed experimental simplicity, and can practically give the same resolving power (about 7000) as with an exit slit. Wave optics is also naturally applicable to calculations of the self-seeding scheme efficiency, which include the monochromator transmittance and the effect of the mismatching between seed beam and electron beam. Simulations show that the FEL power reaches 1 TW and that the spectral density for a TW pulse is about two orders of magnitude higher than that for the SASE pulse at saturation.

  3. Fast continuous energy scan with dynamic coupling of the monochromator and undulator at the DEIMOS beamline.

    Science.gov (United States)

    Joly, L; Otero, E; Choueikani, F; Marteau, F; Chapuis, L; Ohresser, P

    2014-05-01

    In order to improve the efficiency of X-ray absorption data recording, a fast scan method, the Turboscan, has been developed on the DEIMOS beamline at Synchrotron SOLEIL, consisting of a software-synchronized continuous motion of the monochromator and undulator motors. This process suppresses the time loss when waiting for the motors to reach their target positions, as well as software dead-time, while preserving excellent beam characteristics.

  4. Focusing characteristics of diamond crystal x-ray monochromators. An experimental and theoretical comparison

    DEFF Research Database (Denmark)

    Rio, M.S. del; Grübel, G.; Als-Nielsen, J.

    1995-01-01

    Perfect crystals in transmission (Laue) geometry can be used effectively for x-ray monochromators, and moreover, perfect Laue crystals show an interesting focusing effect when the incident beam is white and divergent. This focusing is directly dependent on the incident beam divergence and on the ...... from a diamond crystal in Lane geometry, and we analyze and explain the results by comparison with ray-tracing simulations. (C) 1995 American Institute of Physics....

  5. FEA analysis of diamond as IMCA{close_quote}s monochromator crystal

    Energy Technology Data Exchange (ETDEWEB)

    Chrzas, J.; Cimpoes, S.; Ivanov, I.N. [CSRRI, Illinois Institute of Technology, 3301 S. Dearborn Street, Chicago, IL 60616 (United States)

    1996-09-01

    A great deal of effort has been make in recent years in the field of undulator high heat load optics, and currently there are several tractable options [Rev. Sci. Instrum. {bold 69}, 2792 (1994); Nucl. Instrum. Methods A {bold 266}, 517 (1988); Nucl. Instrum. Methods A {bold 239}, 555 (1993)]. Diamond crystals offer some attractive options{endash}water as the coolant, the use of established monochromator mechanisms, simpler monochromator design as compared to the use of liquid nitrogen or gallium. The use of diamond crystals as the optical elements in a double-crystal monochromator for the IMCA-CAT and MR-CAT ID beamlines has been studied. A first crystal mounting scheme using an indium-gallium eutectic as the heat transfer medium developed in collaboration with DND-CAT and M. Hart will be presented. A FEA analysis of the IMCA-CAT ID beamline arrangement using the APS undulator A as the radiaiton source will be presented. {copyright} {ital 1996 American Institute of Physics.}

  6. Optimization of the polyplanar optical display electronics for a monochrome B-52 display

    Energy Technology Data Exchange (ETDEWEB)

    DeSanto, L.

    1998-04-01

    The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. The prototype ten-inch display is two inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. In order to achieve a long lifetime, the new display uses a new 200 mW green solid-state laser (10,000 hr. life) at 532 nm as its light source. To produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments (TI). In order to use the solid-state laser as the light source and also fit within the constraints of the B-52 display, the Digital Micromirror Device (DMD{trademark}) chip is operated remotely from the Texas Instruments circuit board. In order to achieve increased brightness a monochrome digitizing interface was investigated. The operation of the DMD{trademark} divorced from the light engine and the interfacing of the DMD{trademark} board with the RS-170 video format specific to the B-52 aircraft will be discussed, including the increased brightness of the monochrome digitizing interface. A brief description of the electronics required to drive the new 200 mW laser is also presented.

  7. Milli-electronvolt monochromatization of hard X-rays with a sapphire backscattering monochromator

    Science.gov (United States)

    Sergueev, I.; Wille, H.-C.; Hermann, R. P.; Bessas, D.; Shvyd’ko, Yu. V.; Zając, M.; Rüffer, R.

    2011-01-01

    A sapphire backscattering monochromator with 1.1 (1) meV bandwidth for hard X-rays (20–40 keV) is reported. The optical quality of several sapphire crystals has been studied and the best crystal was chosen to work as the monochromator. The small energy bandwidth has been obtained by decreasing the crystal volume impinged upon by the beam and by choosing the crystal part with the best quality. The monochromator was tested at the energies of the nuclear resonances of 121Sb at 37.13 keV, 125Te at 35.49 keV, 119Sn at 23.88 keV, 149Sm at 22.50 keV and 151Eu at 21.54 keV. For each energy, specific reflections with sapphire temperatures in the 150–300 K region were chosen. Applications to nuclear inelastic scattering with these isotopes are demonstrated. PMID:21862862

  8. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  9. Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Shigeyuki; Mukai, Masaki; Sawada, Hidetaka [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Suenaga, Kazutomo [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565 (Japan)

    2016-01-04

    Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

  10. Frequency stabilization of ambience-isolated internal-mirror He-Ne lasers by thermoelectric-cooling thermal compensation

    Science.gov (United States)

    Shirvani-Mahdavi, Hamidreza; Narges, Yaghoubi

    2016-12-01

    An approach for frequency stabilization of an ambience-isolated internal-mirror He-Ne laser (632.8 nm) utilizing temperature control of the laser tube with Peltier thermoelectric coolers is demonstrated. Measurements indicate that there are an optimal temperature (23 °C) and an optimal discharge current (5.5 mA) of laser tube for which the laser light power is separately maximized. To prevent the effect of fluctuation of discharge current on the laser stability, an adjustable current source is designed and fabricated so that the current is set to be optimal (5.50 ± 0.01 mA). To isolate the laser tube from the environment, the laser metallic box connected to two Peltier thermoelectric coolers is surrounded by two thermal and acoustic insulator shells. The laser has two longitudinal modes very often. Any change in the frequency of longitudinal modes at the optimal temperature is monitored by sampling the difference of longitudinal modes' intensities. Therefore, using a feedback mechanism, the current of thermoelectric coolers is so controlled that the frequency of modes stays constant on the gain profile of the laser. The frequency stability is measured equal to 1.17 × 10-9 (˜2700×) for less than 1 min and 2.57 × 10-9 (˜1200×) for more than 1 h.

  11. Frequency stabilization of ambience-isolated internal-mirror He-Ne lasers by thermoelectric-cooling thermal compensation

    Science.gov (United States)

    Saha, Asit; Pal, Nikhil; Saha, Tapash; Ghorui, M. K.; Chatterjee, Prasanta

    2016-08-01

    An approach for frequency stabilization of an ambience-isolated internal-mirror He-Ne laser (632.8 nm) utilizing temperature control of the laser tube with Peltier thermoelectric coolers is demonstrated. Measurements indicate that there are an optimal temperature (23 °C) and an optimal discharge current (5.5 mA) of laser tube for which the laser light power is separately maximized. To prevent the effect of fluctuation of discharge current on the laser stability, an adjustable current source is designed and fabricated so that the current is set to be optimal (5.50 ± 0.01 mA). To isolate the laser tube from the environment, the laser metallic box connected to two Peltier thermoelectric coolers is surrounded by two thermal and acoustic insulator shells. The laser has two longitudinal modes very often. Any change in the frequency of longitudinal modes at the optimal temperature is monitored by sampling the difference of longitudinal modes' intensities. Therefore, using a feedback mechanism, the current of thermoelectric coolers is so controlled that the frequency of modes stays constant on the gain profile of the laser. The frequency stability is measured equal to 1.17 × 10-9 (˜2700×) for less than 1 min and 2.57 × 10-9 (˜1200×) for more than 1 h.

  12. Danish Cool

    DEFF Research Database (Denmark)

    Toft, Anne Elisabeth

    2016-01-01

    Danish Cool. Keld Helmer-Petersen, Photography and the Photobook Handout exhibition text in English and Chinese by Anne Elisabeth Toft, Curator The exhibition Danish Cool. Keld Helmer-Petersen, Photography and the Photobook presents the ground-breaking work of late Danish photographer Keld Helmer...

  13. Comparison of the commercial color LCD and the medical monochrome LCD using randomized object test patterns.

    Directory of Open Access Journals (Sweden)

    Jay Wu

    Full Text Available Workstations and electronic display devices in a picture archiving and communication system (PACS provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265 and OT (p = 0.07. The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration.

  14. Comparison of the commercial color LCD and the medical monochrome LCD using randomized object test patterns.

    Science.gov (United States)

    Wu, Jay; Wu, Tung H; Han, Rou P; Chang, Shu J; Shih, Cheng T; Sun, Jing Y; Hsu, Shih M

    2012-01-01

    Workstations and electronic display devices in a picture archiving and communication system (PACS) provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs) consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP) commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC) analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC) for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT) was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265) and OT (p = 0.07). The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration.

  15. A New Flexible Monochromator Setup for Quick Scanning X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stotzel, J.; Lutzenkirchen-Hecht, D; Frahm, R

    2010-01-01

    A new monochromator setup for quick scanning x-ray absorption spectroscopy in the subsecond time regime is presented. Novel driving mechanics allow changing the energy range of the acquired spectra by remote control during data acquisition for the first time, thus dramatically increasing the flexibility and convenience of this method. Completely new experiments are feasible due to the fact that time resolution, edge energy, and energy range of the acquired spectra can be changed continuously within seconds without breaking the vacuum of the monochromator vessel and even without interrupting the measurements. The advanced mechanics are explained in detail and the performance is characterized with x-ray absorption spectra of pure metal foils. The energy scale was determined by a fast and accurate angular encoder system measuring the Bragg angle of the monochromator crystal with subarcsecond resolution. The Bragg angle range covered by the oscillating crystal can currently be changed from 0{sup o} to 3.0{sup o} within 20 s, while the mechanics are capable to move with frequencies of up to ca. 35 Hz, leading to ca. 14 ms/spectrum time resolution. A new software package allows performing programmed scan sequences, which enable the user to measure stepwise with alternating parameters in predefined time segments. Thus, e.g., switching between edges scanned with the same energy range is possible within one in situ experiment, while also the time resolution can be varied simultaneously. This progress makes the new system extremely user friendly and efficient to use for time resolved x-ray absorption spectroscopy at synchrotron radiation beamlines.

  16. A new flexible monochromator setup for quick scanning x-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stoetzel, J.; Luetzenkirchen-Hecht, D.; Frahm, R. [Fachbereich C, Physik, Bergische Universitaet Wuppertal, Gaussstr. 20, 42097 Wuppertal (Germany)

    2010-07-15

    A new monochromator setup for quick scanning x-ray absorption spectroscopy in the subsecond time regime is presented. Novel driving mechanics allow changing the energy range of the acquired spectra by remote control during data acquisition for the first time, thus dramatically increasing the flexibility and convenience of this method. Completely new experiments are feasible due to the fact that time resolution, edge energy, and energy range of the acquired spectra can be changed continuously within seconds without breaking the vacuum of the monochromator vessel and even without interrupting the measurements. The advanced mechanics are explained in detail and the performance is characterized with x-ray absorption spectra of pure metal foils. The energy scale was determined by a fast and accurate angular encoder system measuring the Bragg angle of the monochromator crystal with subarcsecond resolution. The Bragg angle range covered by the oscillating crystal can currently be changed from 0 deg. to 3.0 deg. within 20 s, while the mechanics are capable to move with frequencies of up to ca. 35 Hz, leading to ca. 14 ms/spectrum time resolution. A new software package allows performing programmed scan sequences, which enable the user to measure stepwise with alternating parameters in predefined time segments. Thus, e.g., switching between edges scanned with the same energy range is possible within one in situ experiment, while also the time resolution can be varied simultaneously. This progress makes the new system extremely user friendly and efficient to use for time resolved x-ray absorption spectroscopy at synchrotron radiation beamlines.

  17. A new gradient monochromator for the IN13 back-scattering spectrometer

    Science.gov (United States)

    Ciampolini, L.; Bove, L. E.; Mondelli, C.; Alianelli, L.; Labbe-Lavigne, S.; Natali, F.; Bée, M.; Deriu, A.

    2005-06-01

    We present new McStas simulations of the back-scattering thermal neutron spectrometer IN13 to evaluate the advantages of a new temperature gradient monochromator relative to a conventional one. The simulations show that a flux gain up to a factor 7 can be obtained with just a 10% loss in energy resolution and a 20% increase in beam spot size at the sample. The results also indicate that a moderate applied temperature gradient (ΔT≃16 K) is sufficient to obtain this significant flux gain.

  18. A new gradient monochromator for the IN13 back-scattering spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ciampolini, L. [Istituto Nazionale per la Fisica della Materia, Unita di Parma (Italy)]. E-mail: ciampolinil@ieee.org; Bove, L.E. [Istituto Nazionale per la Fisica della Materia, OGG, ILL Grenoble (France); Mondelli, C. [Istituto Nazionale per la Fisica della Materia, OGG, ILL Grenoble (France); Alianelli, L. [Istituto Nazionale per la Fisica della Materia, OGG, ILL Grenoble (France); Institut Laue Langevin, Grenoble (France); Labbe-Lavigne, S. [CNRS, Grenoble (France); Natali, F. [Istituto Nazionale per la Fisica della Materia, OGG, ILL Grenoble (France); Bee, M. [Universite Joseph Fourier, Grenoble (France); Deriu, A. [Istituto Nazionale per la Fisica della Materia, Unita di Parma (Italy); Dipartimento di Fisica, Universita di Parma (Italy)

    2005-06-01

    We present new McStas simulations of the back-scattering thermal neutron spectrometer IN13 to evaluate the advantages of a new temperature gradient monochromator relative to a conventional one. The simulations show that a flux gain up to a factor 7 can be obtained with just a 10% loss in energy resolution and a 20% increase in beam spot size at the sample. The results also indicate that a moderate applied temperature gradient ({delta}T{approx}16K) is sufficient to obtain this significant flux gain. n.

  19. Synchronous scanning of undulator gap and monochromator for XAFS measurements in soft x-ray region.

    Science.gov (United States)

    Tanaka, T; Matsubayashi, N; Imamura, M; Shimada, H

    2001-03-01

    Synchronous scanning of the undulator gap and a monochromator was done to obtain smooth profiles of incident x-rays that are suitable for XAFS measurements. By changing the gap from 150 mm(B=0.12 T) to 140 mm (B=0.15 T) with the use of the 3rd to 11th harmonic peaks, soft x-rays with energy from 200 eV to 1200 eV were obtained. The smooth profile of the incident x-rays provided high-quality measurement of XANES and EXAFS spectra in the soft x-ray region. Issues that would improve the synchronous scanning system are discussed.

  20. Ultra high energy resolution focusing monochromator for inelastic X-ray scattering spectrometer

    CERN Document Server

    Suvorov, A; Chubar, O; Cai, Y Q

    2015-01-01

    A further development of a focusing monochromator concept for X-ray energy resolution of 0.1 meV and below is presented. Theoretical analysis of several optical layouts based on this concept was supported by numerical simulations performed in the "Synchrotron Radiation Workshop" software package using the physical-optics approach and careful modeling of partially-coherent synchrotron (undulator) radiation. Along with the energy resolution, the spectral shape of the energy resolution function was investigated. It was shown that under certain conditions the decay of the resolution function tails can be faster than that of the Gaussian function.

  1. Reuso de efluentes em torres de resfriamento - estudo conceitual: Aeroporto Internacional do Rio de Janeiro = Water reuse for cooling towers – conceptual study: Rio de Janeiro International Airport

    Directory of Open Access Journals (Sweden)

    Denize Dias de Carvalho

    2010-07-01

    Full Text Available O reuso de água é ferramenta valiosa na gestão da água, que promove a otimização da utilização do recurso desta, que reduz e, muitas vezes, até elimina os impactos no meio ambiente. Neste trabalho foi investigada a composição do efluente secundário da estação de tratamento de efluentes (ETE APOIO do Aeroporto Internacional do Rio de Janeiro, com o objetivo de propor o processo adequado à reutilização deste efluente como água de reposição nas torres de resfriamento desse Aeroporto. Com base nas análises de cátions, ânions, DBO e DQO, verificou-se o parâmetro SDT - Cl- como crítico para processamento do efluente. Foi proposta uma sequência para reutilização do efluente que continha o tratamento de osmose inversa, o custo do m3 produzido por essa sequência foi estimado em R$ 2,90 m-3. Water reuse is an important tool in water management; it is a conceptthat promotes optimization of the water resource, reducing and often even eliminating environmental impacts. In this work, the composition of a secondary effluent (from the effluent treatment station (ETE APOIO at Rio de Janeiro International Airport was analyzed, with theaim of determining an adequate process for the reutilization of this effluent as replacement cooling water. Chemical analyses such as cation and anion analysis, BOD and COD were performed. Based on these analyses, it was found that TDS - Cl- was the critical parameter foreffluent processing. A treatment system was proposed for effluent reuse including reverse osmosis; the cost estimate per m3 produced by this system was R$ 2.90 m-3.

  2. Optimisation and fabrication of a composite pyrolytic graphite monochromator for the Pelican instrument at the ANSTO OPAL reactor

    Science.gov (United States)

    Freund, A. K.; Yu, D. H.

    2011-04-01

    The triple monochromator for the TOF neutron spectrometer Pelican at ANSTO has been fully optimised in terms of overall performance, including the determination of the thickness of the pyrolytic graphite crystals. A total of 24 composite crystals were designed and fabricated. The calculated optimum thickness of 1.3 mm and the length of 15 cm of the monochromator crystals, that are not available commercially, were obtained by cleaving and soldering with indium. An extensive characterisation of the crystals using X-ray and neutron diffraction was conducted before and after the cleaving and bonding processes. The results proved that no damage was introduced during fabrication and showed that the design goals were fully met. The measured peak reflectivity and rocking curve widths were indeed in an excellent agreement with theory. In addition to the superior efficiency of the triple monochromator achieved by this novel approach, the amount of the crystal material required could be reduced by 1/3.

  3. Self-seeding scheme with gas monochromator for narrow-bandwidth soft X-ray FELs

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni

    2011-01-01

    Self-seeding schemes, consisting of two undulators with a monochromator in between, aim at reducing the bandwidth of SASE X-ray FELs. We recently proposed to use a new method of monochromatization exploiting a single crystal in Bragg-transmission geometry for self-seeding in the hard X-ray range. Here we consider a possible extension of this method to the soft X-ray range using a cell filled with resonantly absorbing gas as monochromator. The transmittance spectrum in the gas exhibits an absorbing resonance with narrow bandwidth. Then, similarly to the hard X-ray case, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. In fact, the FEL pulse forces the gas atoms to oscillate in a way consistent with a forward-propagating, monochromatic radiation beam. The radiation power within this wake is much larger than the equivalent shot noise power in the electron bunch. Further on, the monochromatic wake of the radiation pulse is combined with the delayed electron b...

  4. $YB_{66} a new soft X-ray monochromator for synchrotron radiation

    CERN Document Server

    Wong, J; Rowen, M; Schäfers, F; Müller, B R; Rek, Z U

    1999-01-01

    For pt.I see Nucl. Instrum. Methods Phys. Res., vol.A291, p.243-8, 1990. YB/sub 66/, a complex boron-rich man-made crystal, has been singled out as a potential monochromator material to disperse synchrotron soft X-rays in the 1-2 keV region. Results of a series of systematic property characterizations pertinent for this application are presented in this paper. These include Laue diffraction patterns and high-precision lattice-constant determination, etch rate, stoichiometry, thermal expansion, soft X-ray reflectivity and rocking-curve measurements, thermal load effects on monochromator performance, nature of intrinsic positive glitches and their reduction. The 004 reflection of YB/sub 66/ has a reflectance of ~3 in this spectral region. The width of the rocking curve varies from 0.25 eV at 1.1 keV to 1.0 eV at 2 keV, which is a factor of two better than that of beryl(1010) in the same energy range, and enables measurements of high-resolution XANES spectra at the Mg, Al and Si K- edges. The thermal bump on the...

  5. An independent survey of monochrome and color low light level TV cameras

    Science.gov (United States)

    Preece, Bradley L.; Tomkinson, David M.; Reynolds, Joseph P.

    2015-05-01

    Using the latest models from the U.S. Army Night Vision Electronic Sensors Directorate (NVESD), a survey of monochrome and color imaging systems at daylight and low light levels is conducted. Each camera system is evaluated and compared under several different assumptions, such as equivalent field of view with equal and variable f/#, common lens focal length and aperture, with high dynamic range comparisons and over several light levels. The modeling is done by use of the Targeting Task Performance (TTP) metric using the latest version of the Night Vision Integrated Performance Model (NV⁸IPM). The comparison is performed over the V parameter, the main output of the TTP metric. Probability of identification (PID) versus range predictions are a direct non-linear mapping of the V parameter as a function of range. Finally, a comparison between the performance of a Bayer-filtered color camera, the Bayer-filtered color camera with the IR block filter removed, and a monochrome version of the same camera is also conducted.

  6. Grating monochromator for soft X-ray self-seeding the European XFEL

    CERN Document Server

    Serkez, Svitozar; Kocharyan, Vitali; Saldin, Evgeni

    2013-01-01

    Self-seeding is a promising approach to significantly narrow the SASE bandwidth of XFELs to produce nearly transform-limited pulses. The implementation of this method in the soft X-ray wavelength range necessarily involves gratings as dispersive elements. We study a very compact self-seeding scheme with a grating monochromator originally designed at SLAC, which can be straightforwardly installed in the SASE3 type undulator beamline at the European XFEL. The monochromator design is based on a toroidal VLS grating working at a fixed incidence angle mounting without entrance slit. It covers the spectral range from 300 eV to 1000 eV. The optical system was studied using wave optics method (in comparison with ray tracing) to evaluate the performance of the self-seeding scheme. Our wave optics analysis takes into account the actual beam wavefront of the radiation from the coherent FEL source, third order aberrations, and errors from each optical element. Wave optics is the only method available, in combination with...

  7. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Energy Technology Data Exchange (ETDEWEB)

    Kristiansen, Paw, E-mail: paw.kristiansen@fmb-oxford.com [FMB Oxford Ltd, Unit 1 Ferry Mills, Oxford OX2 0ES (United Kingdom); Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim [DESY, Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany)

    2015-05-09

    Vibration measurements of a cryocooled double-crystal monochromator are presented. The origins of the vibrations are identified. The minimum achieved vibration of the relative pitch between the two crystals is 48 nrad RMS and the minimum achieved absolute vibration of the second crystal is 82 nrad RMS. The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged.

  8. Italian panoramic monochromator for the THEMIS telescope: the first results and instrument evaluation

    Science.gov (United States)

    Cavallini, Fabio; Berrilli, Francesco; Caccin, Bruno; Cantarano, Sergio; Ceppatelli, Guido; Egidi, Alberto; Righini, Alberto

    1998-07-01

    We briefly describe the design and the characteristics of the Italian Panoramic Monochromator installed at the focal plane of the THEMIS telescope built in Izana by a joint venture of the French and Italian National Research Councils. The Panoramic Monochromator substantially is a narrow band filter (approximately equals 22 mAngstrom bandwidth) tunable on the visible spectrum for quasi simultaneous bidimensional spectrometry of the solar atmosphere. The narrow bandwidth is obtained by using a non standard birefringent filter and a Fabry Perot interferometer mounted in series. This assembly has the advantage of the spectral purity of one channel of the Fabry Perot interferometer and a very large free spectral range. Moreover the spectral stability depends on the interferometer, the environment of which may be carefully controlled. The design of this instrument is not really new, but, only now it has been possible to build it thanks to the development of servo controlled Fabry Perot interferometers, which are stable in time and may easily be tuned. The system seems to perform well. It is stable in wavelength and the spectral pass band and stray light are within the expected values, as it may be deduced by very preliminary tests performed at the THEMIS Telescope and in Arcetri (Firenze) at the 'G. B. Donati' solar tower.

  9. Design and fabrication of an active polynomial grating for soft-X-ray monochromators and spectrometers

    CERN Document Server

    Chen, S J; Perng, S Y; Kuan, C K; Tseng, T C; Wang, D J

    2001-01-01

    An active polynomial grating has been designed for use in synchrotron radiation soft-X-ray monochromators and spectrometers. The grating can be dynamically adjusted to obtain the third-order-polynomial surface needed to eliminate the defocus and coma aberrations at any photon energy. Ray-tracing results confirm that a monochromator or spectrometer based on this active grating has nearly no aberration limit to the overall spectral resolution in the entire soft-X-ray region. The grating substrate is made of a precisely milled 17-4 PH stainless steel parallel plate, which is joined to a flexure-hinge bender shaped by wire electrical discharge machining. The substrate is grounded into a concave cylindrical shape with a nominal radius and then polished to achieve a roughness of 0.45 nm and a slope error of 1.2 mu rad rms. The long trace profiler measurements show that the active grating can reach the desired third-order polynomial with a high degree of figure accuracy.

  10. Design and fabrication of an active polynomial grating for soft-X-ray monochromators and spectrometers

    Science.gov (United States)

    Chen, S.-J.; Chen, C. T.; Perng, S. Y.; Kuan, C. K.; Tseng, T. C.; Wang, D. J.

    2001-07-01

    An active polynomial grating has been designed for use in synchrotron radiation soft-X-ray monochromators and spectrometers. The grating can be dynamically adjusted to obtain the third-order-polynomial surface needed to eliminate the defocus and coma aberrations at any photon energy. Ray-tracing results confirm that a monochromator or spectrometer based on this active grating has nearly no aberration limit to the overall spectral resolution in the entire soft-X-ray region. The grating substrate is made of a precisely milled 17-4 PH stainless steel parallel plate, which is joined to a flexure-hinge bender shaped by wire electrical discharge machining. The substrate is grounded into a concave cylindrical shape with a nominal radius and then polished to achieve a roughness of 0.45 nm and a slope error of 1.2 μrad rms. The long trace profiler measurements show that the active grating can reach the desired third-order polynomial with a high degree of figure accuracy.

  11. High-resolution monochromator for iron nuclear resonance vibrational spectroscopy of biological samples

    Science.gov (United States)

    Yoda, Yoshitaka; Okada, Kyoko; Wang, Hongxin; Cramer, Stephen P.; Seto, Makoto

    2016-12-01

    A new high-resolution monochromator for 14.4-keV X-rays has been designed and developed for the Fe nuclear resonance vibrational spectroscopy of biological samples. In addition to high resolution, higher flux and stability are especially important for measuring biological samples, because of the very weak signals produced due to the low concentrations of Fe-57. A 24% increase in flux while maintaining a high resolution better than 0.9 meV is achieved in the calculation by adopting an asymmetric reflection of Ge, which is used as the first crystal of the three-bounce high-resolution monochromator. A 20% increase of the exit beam size is acceptable to our biological applications. The higher throughput of the new design has been experimentally verified. A fine rotation mechanics that combines a weak-link hinge with a piezoelectric actuator was used for controlling the photon energy of the monochromatic beam. The resulting stability is sufficient to preserve the intrinsic resolution.

  12. A coded structured light system based on primary color stripe projection and monochrome imaging.

    Science.gov (United States)

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2013-10-14

    Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy.

  13. A Coded Structured Light System Based on Primary Color Stripe Projection and Monochrome Imaging

    Directory of Open Access Journals (Sweden)

    Armando Viviano Razionale

    2013-10-01

    Full Text Available Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy.

  14. Optimization of a constrained linear monochromator design for neutral atom beams.

    Science.gov (United States)

    Kaltenbacher, Thomas

    2016-04-01

    A focused ground state, neutral atom beam, exploiting its de Broglie wavelength by means of atom optics, is used for neutral atom microscopy imaging. Employing Fresnel zone plates as a lens for these beams is a well established microscopy technique. To date, even for favorable beam source conditions a minimal focus spot size of slightly below 1μm was reached. This limitation is essentially given by the intrinsic spectral purity of the beam in combination with the chromatic aberration of the diffraction based zone plate. Therefore, it is important to enhance the monochromaticity of the beam, enabling a higher spatial resolution, preferably below 100nm. We propose to increase the monochromaticity of a neutral atom beam by means of a so-called linear monochromator set-up - a Fresnel zone plate in combination with a pinhole aperture - in order to gain more than one order of magnitude in spatial resolution. This configuration is known in X-ray microscopy and has proven to be useful, but has not been applied to neutral atom beams. The main result of this work is optimal design parameters based on models for this linear monochromator set-up followed by a second zone plate for focusing. The optimization was performed for minimizing the focal spot size and maximizing the centre line intensity at the detector position for an atom beam simultaneously. The results presented in this work are for, but not limited to, a neutral helium atom beam.

  15. Inductively coupled plasma-atomic emission spectroscopy: a computer controlled, scanning monochromator system for the rapid determination of the elements

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, M.A.

    1980-03-01

    A computer controlled, scanning monochromator system specifically designed for the rapid, sequential determination of the elements is described. The monochromator is combined with an inductively coupled plasma excitation source so that elements at major, minor, trace, and ultratrace levels may be determined, in sequence, without changing experimental parameters other than the spectral line observed. A number of distinctive features not found in previously described versions are incorporated into the system here described. Performance characteristics of the entire system and several analytical applications are discussed.

  16. A diffracted-beam monochromator for long linear detectors in X-ray diffractometers with Bragg-Brentano parafocusing geometry.

    Science.gov (United States)

    van der Pers, N M; Hendrikx, R W A; Delhez, R; Böttger, A J

    2013-04-01

    A new diffracted-beam monochromator has been developed for Bragg-Brentano X-ray diffractometers equipped with a linear detector. The monochromator consists of a cone-shaped graphite highly oriented pyrolytic graphite crystal oriented out of the equatorial plane such that the parafocusing geometry is preserved over the whole opening angle of the linear detector. In our standard setup a maximum wavelength discrimination of 3% is achieved with an overall efficiency of 20% and a small decrease in angular resolution of only 0.02 °2θ. In principle, an energy resolution as low as 1.5% can be achieved.

  17. Theoretical analysis of the performance of different cooling strategies with the concept of cool exergy

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    The whole chains of exergy flows for different cooling systems were compared. The effects of cooling demand (internal vs. external solar shading), space cooling method (floor cooling vs. air cooling with ventilation system), and the availability of a nearby natural heat sink (intake air for the v......The whole chains of exergy flows for different cooling systems were compared. The effects of cooling demand (internal vs. external solar shading), space cooling method (floor cooling vs. air cooling with ventilation system), and the availability of a nearby natural heat sink (intake air......-water, etc.) and indoor terminal units, only with a minimized demand. The water-based floor cooling system performed better than the air-based cooling system; when an air-to-water heat pump was used as the cooling source, the required exergy input was 28% smaller for the floor cooling system. The auxiliary...... exergy input of air-based systems was significantly larger than the water-based systems. The use of available cool exergy in the crawl-space resulted in 54% and 29% smaller exergy input to the power plant for the air-based and water-based cooling systems, respectively. For floor cooling, the exergy input...

  18. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state...

  19. Cool snacks

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Brock, Steen; Brunsø, Karen

    2016-01-01

    such a product requires an interdisciplinary effort where researchers with backgrounds in psychology, anthropology, media science, philosophy, sensory science and food science join forces. We present the COOL SNACKS project, where such a blend of competences was used first to obtain thorough insight into young...

  20. Stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Bisognano, J.; Leemann, C.

    1982-03-01

    Stochastic cooling is the damping of betatron oscillations and momentum spread of a particle beam by a feedback system. In its simplest form, a pickup electrode detects the transverse positions or momenta of particles in a storage ring, and the signal produced is amplified and applied downstream to a kicker. The time delay of the cable and electronics is designed to match the transit time of particles along the arc of the storage ring between the pickup and kicker so that an individual particle receives the amplified version of the signal it produced at the pick-up. If there were only a single particle in the ring, it is obvious that betatron oscillations and momentum offset could be damped. However, in addition to its own signal, a particle receives signals from other beam particles. In the limit of an infinite number of particles, no damping could be achieved; we have Liouville's theorem with constant density of the phase space fluid. For a finite, albeit large number of particles, there remains a residue of the single particle damping which is of practical use in accumulating low phase space density beams of particles such as antiprotons. It was the realization of this fact that led to the invention of stochastic cooling by S. van der Meer in 1968. Since its conception, stochastic cooling has been the subject of much theoretical and experimental work. The earliest experiments were performed at the ISR in 1974, with the subsequent ICE studies firmly establishing the stochastic cooling technique. This work directly led to the design and construction of the Antiproton Accumulator at CERN and the beginnings of p anti p colliding beam physics at the SPS. Experiments in stochastic cooling have been performed at Fermilab in collaboration with LBL, and a design is currently under development for a anti p accumulator for the Tevatron.

  1. Multispectral integral imaging acquisition and processing using a monochrome camera and a liquid crystal tunable filter.

    Science.gov (United States)

    Latorre-Carmona, Pedro; Sánchez-Ortiga, Emilio; Xiao, Xiao; Pla, Filiberto; Martínez-Corral, Manuel; Navarro, Héctor; Saavedra, Genaro; Javidi, Bahram

    2012-11-01

    This paper presents an acquisition system and a procedure to capture 3D scenes in different spectral bands. The acquisition system is formed by a monochrome camera, and a Liquid Crystal Tunable Filter (LCTF) that allows to acquire images at different spectral bands in the [480, 680]nm wavelength interval. The Synthetic Aperture Integral Imaging acquisition technique is used to obtain the elemental images for each wavelength. These elemental images are used to computationally obtain the reconstruction planes of the 3D scene at different depth planes. The 3D profile of the acquired scene is also obtained using a minimization of the variance of the contribution of the elemental images at each image pixel. Experimental results show the viability to recover the 3D multispectral information of the scene. Integration of 3D and multispectral information could have important benefits in different areas, including skin cancer detection, remote sensing and pattern recognition, among others.

  2. The sapphire backscattering monochromator at the Dynamics beamline P01 of PETRA III

    Science.gov (United States)

    Alexeev, P.; Asadchikov, V.; Bessas, D.; Butashin, A.; Deryabin, A.; Dill, F.-U.; Ehnes, A.; Herlitschke, M.; Hermann, R. P.; Jafari, A.; Prokhorov, I.; Roshchin, B.; Röhlsberger, R.; Schlage, K.; Sergueev, I.; Siemens, A.; Wille, H.-C.

    2016-12-01

    We report on a high resolution sapphire backscattering monochromator installed at the Dynamics beamline P01 of PETRA III. The device enables nuclear resonance scattering experiments on Mössbauer isotopes with transition energies between 20 and 60 keV with sub-meV to meV resolution. In a first performance test with 119Sn nuclear resonance at a X-ray energy of 23.88 keV an energy resolution of 1.34 meV was achieved. The device extends the field of nuclear resonance scattering at the PETRA III synchrotron light source to many further isotopes like 151Eu, 149Sm, 161Dy, 125Te and 121Sb.

  3. Flux-enhanced monochromator by ultrasound excitation of annealed Czochralski-grown silicon crystals

    CERN Document Server

    Koehler, S; Seitz, C; Magerl, A; Mashkina, E; Demin, A

    2003-01-01

    The neutron flux from monochromator crystals can be increased by ultrasound excitation or by strain fields. Rocking curves of both a perfect float-zone silicon crystal and an annealed Czochralski silicon crystal with oxygen precipitates were measured at various levels of ultrasound excitation on a cold-neutron backscattering spectrometer. We find that the effects of the dynamic strain field from the ultrasound and the static strain field from the defects are not additive. Rocking curves were also taken at different ultrasound frequencies near resonance of the crystal/ultrasound-transducer system with a time resolution of 1 min. Pronounced effects of crystal heating are observed, which render the conditions for maximum neutron reflectivity delicate. (orig.)

  4. Measuring the criticality of the `magic condition' for a beam-expanding monochromator.

    Science.gov (United States)

    Martinson, Mercedes; Chapman, Dean

    2016-11-01

    It has been established that for cylindrically bent crystals the optimal beam characteristics occur when the geometric and single-ray foci are matched. In the beam-expanding monochromator developed for the BioMedical Imaging and Therapy beamlines at the Canadian Light Source, it was unclear how critical this `magic condition' was for preserving the transverse coherence of the beam. A study was conducted to determine whether misalignments away from the ideal conditions would severely affect the transverse coherence of the beam, thereby limiting phase-based imaging techniques. The results were that the magic condition has enough flexibility to accommodate deviations of about ±1° or ±5 keV.

  5. Adaptive silicon monochromators for high-power wigglers; design, finite-element analysis and laboratory tests.

    Science.gov (United States)

    Quintana, J P; Hart, M

    1995-05-01

    Multipole wigglers in storage rings already produce X-ray power in the range up to a few kilowatts and planned devices at third-generation facilities promise up to 30 kW. Although the power density at the monochromator position is an order of magnitude lower than that from undulators, the thermal strain field in the beam footprint can still cause severe loss of performance in X-ray optical systems. For an optimized adaptive design, the results of finite-element analysis are compared with double-crystal rocking curves obtained with a laboratory X-ray source and, in a second paper [Quintana, Hart, Bilderback, Henderson, Richter, Setterson, White, Hausermann, Krumrey & Schulte-Schrepping (1995). J. Synchotron Rad. 2, 1-5], successful tests at wiggler sources at CHESS and ESRF and in an undulator source at HASYLAB are reported.

  6. A methodology for visually lossless JPEG2000 compression of monochrome stereo images.

    Science.gov (United States)

    Feng, Hsin-Chang; Marcellin, Michael W; Bilgin, Ali

    2015-02-01

    A methodology for visually lossless compression of monochrome stereoscopic 3D images is proposed. Visibility thresholds are measured for quantization distortion in JPEG2000. These thresholds are found to be functions of not only spatial frequency, but also of wavelet coefficient variance, as well as the gray level in both the left and right images. To avoid a daunting number of measurements during subjective experiments, a model for visibility thresholds is developed. The left image and right image of a stereo pair are then compressed jointly using the visibility thresholds obtained from the proposed model to ensure that quantization errors in each image are imperceptible to both eyes. This methodology is then demonstrated via a particular 3D stereoscopic display system with an associated viewing condition. The resulting images are visually lossless when displayed individually as 2D images, and also when displayed in stereoscopic 3D mode.

  7. Image-quality assessment of monochrome monitors for medical soft copy display

    Science.gov (United States)

    Weibrecht, Martin; Spekowius, Gerhard; Quadflieg, Peter; Blume, Hartwig R.

    1997-05-01

    Soft-copy presentation of medical images is becoming part of the medical routine as more and more health care facilities are converted to digital filmless hospital and radiological information management. To provide optimal image quality, display systems must be incorporated when assessing the overall system image quality. We developed a method to accomplish this. The proper working of the method is demonstrated with the analysis of four different monochrome monitors. We determined display functions and veiling glare with a high-performance photometer. Structure mottle of the CRT screens, point spread functions and images of stochastic structures were acquired by a scientific CCD camera. The images were analyzed with respect to signal transfer characteristics and noise power spectra. We determined the influence of the monitors on the detective quantum efficiency of a simulated digital x-ray imaging system. The method follows a physical approach; nevertheless, the results of the analysis are in good agreement with the subjective impression of human observers.

  8. A Drabkin-type spin resonator as tunable neutron beam monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Piegsa, F.M., E-mail: florian.piegsa@phys.ethz.ch [ETH Zürich, Institute for Particle Physics, CH-8093 Zürich (Switzerland); Ries, D. [ETH Zürich, Institute for Particle Physics, CH-8093 Zürich (Switzerland); Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Filges, U.; Hautle, P. [Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2015-09-11

    A Drabkin-type spin resonator was designed and successfully implemented at the multi-purpose beam line BOA at the spallation neutron source SINQ at the Paul Scherrer Institute. The device selectively acts on the magnetic moment of neutrons within an adjustable velocity band and hence can be utilized as a tunable neutron beam monochromator. Several neutron time-of-flight (TOF) spectra have been recorded employing various settings in order to characterize its performance. In a first test application the velocity dependent transmission of a beryllium filter was determined. In addition, we demonstrate that using an exponential current distribution in the spin resonator coil the side-maxima in the TOF spectra usually associated with a Drabkin setup can be strongly suppressed.

  9. Diffraction imaging for in-situ characterization of double-crystal x-ray monochromators

    CERN Document Server

    Stoupin, Stanislav; Heald, Steve M; Brewe, Dale; Meron, Mati

    2015-01-01

    Imaging of the Bragg reflected x-ray beam is proposed and validated as an in-situ method for characterization of performance of double-crystal monochromators under the heat load of intense synchrotron radiation. A sequence of images is collected at different angular positions on the reflectivity curve of the second crystal and analyzed. The method provides rapid evaluation of the wavefront of the exit beam, which relates to local misorientation of the crystal planes along the beam footprint on the thermally distorted first crystal. The measured misorientation can be directly compared to results of finite element analysis. The imaging method offers an additional insight on the local intrinsic crystal quality over the footprint of the incident x-ray beam.

  10. Bragg prism monochromator and analyser for super ultra-small angle neutron scattering studies

    Indian Academy of Sciences (India)

    Apoorva G Wagh; Sohrab Abbas; Markus Strobl; Wolfgang Treimer

    2008-11-01

    We have designed, fabricated and operated a novel Bragg prism monochromator–analyser combination. With a judicious choice of the Bragg reflection, its asymmetry and the apex angle of the silicon single crystal prism, the monochromator has produced a neutron beam with sub-arcsec collimation. A Bragg prism analyser with the opposite asymmetry has been tailored to accept a still sharper angular profile. With this optimized monochromator–analyser pair, we have attained the narrowest and sharpest neutron angular profile to date. At this facility, we have recorded the first SUSANS spectra spanning wave vector transfers ∼ 10−6 Å-1 to characterize samples containing agglomerates up to tens of micrometres in size.

  11. On the sagittal focusing of synchrotron radiation with a double crystal monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Kushnir, V.I.; Quintana, J.P.; Georgopoulos, P. (DUNU Synchrotron Research Center, Robert R. McCormick School of Engineering and Applied Science, Northwestern Univ., Evanston, IL (United States))

    1993-05-01

    A method to avoid the anticlastic bending of the second crystal in a two-crystal monochromator for synchrotron radiation is proposed. It is analytically shown that the anticlastic curvature is zero at the center of the crystal for a simply supported isotropic crystal loaded with a constant moment provided that the crystal's aspect ratio is equal to a 'golden value' dependent on the Poisson coefficient [nu]. For [nu]=0.262 (equal to [nu] in the Si(111) plane) this ratio is 2.360. Finite element results are presented on the case of the clamped crystal and show that there is a similar 'golden value' approximately equal to 1.42 for [nu]=0.262. (orig.).

  12. High-aperture monochromator-reflectometer and its usefulness for CCD calibration

    Science.gov (United States)

    Vishnyakov, Eugene A.; Shcherbakov, Alexander V.; Pertsov, Andrei A.; Polkovnikov, Vladimir N.; Pestov, Alexey E.; Pariev, Dmitry E.; Chkhalo, Nikolai I.

    2017-05-01

    We present a laboratory high-aperture monochromator-reflectometer employing laser-plasma radiation source and three replaceable Schwarzschild objectives for a certain range of applications in the soft X-ray spectral waveband. Three sets of X-ray multilayer mirrors for the Schwarzschild objectives enable operation of the reflectometer at the wavelengths of 135, 171 and 304 Å, while a goniometer with three degrees of freedom allows different measurement modes. We have used the facility for a laboratory CCD calibration at the wavelengths specified. Combined with the results of the CCD sensitivity measurements conducted in the VUV spectral waveband, the total outcome provides a more comprehensive understanding of the CCD effectivity in a wide spectral range.

  13. High-resolution monochromated electron energy-loss spectroscopy of organic photovoltaic materials.

    Science.gov (United States)

    Alexander, Jessica A; Scheltens, Frank J; Drummy, Lawrence F; Durstock, Michael F; Hage, Fredrik S; Ramasse, Quentin M; McComb, David W

    2017-09-01

    Advances in electron monochromator technology are providing opportunities for high energy resolution (10 - 200meV) electron energy-loss spectroscopy (EELS) to be performed in the scanning transmission electron microscope (STEM). The energy-loss near-edge structure in core-loss spectroscopy is often limited by core-hole lifetimes rather than the energy spread of the incident illumination. However, in the valence-loss region, the reduced width of the zero loss peak makes it possible to resolve clearly and unambiguously spectral features at very low energy-losses (photovoltaics (OPVs): poly(3-hexlythiophene) (P3HT), [6,6] phenyl-C61 butyric acid methyl ester (PCBM), copper phthalocyanine (CuPc), and fullerene (C60). Data was collected on two different monochromated instruments - a Nion UltraSTEM 100 MC 'HERMES' and a FEI Titan(3) 60-300 Image-Corrected S/TEM - using energy resolutions (as defined by the zero loss peak full-width at half-maximum) of 35meV and 175meV, respectively. The data was acquired to allow deconvolution of plural scattering, and Kramers-Kronig analysis was utilized to extract the complex dielectric functions. The real and imaginary parts of the complex dielectric functions obtained from the two instruments were compared to evaluate if the enhanced resolution in the Nion provides new opto-electronic information for these organic materials. The differences between the spectra are discussed, and the implications for STEM-EELS studies of advanced materials are considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Rotation of X-ray polarization in the glitches of a silicon crystal monochromator.

    Science.gov (United States)

    Sutter, John P; Boada, Roberto; Bowron, Daniel T; Stepanov, Sergey A; Díaz-Moreno, Sofía

    2016-08-01

    EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the 'glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO3)2. The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

  15. Cooling circuit for a gas turbine bucket and tip shroud

    Energy Technology Data Exchange (ETDEWEB)

    Willett, Fred Thomas (25 Long Creek Dr., Burnt Hills, NY 12027); Itzel, Gary Michael (12 Cider Mill Dr., Clifton Park, NY 12065); Stathopoulos, Dimitrios (11 Wyngate Rd., Glenmont, NY 12077); Plemmons, Larry Wayne (late of Hamilton, OH); Plemmons, Helen M. (2900 Long Ridge Trails, Hamilton, OH 45014); Lewis, Doyle C. (444 River Way, Greer, SC 29651)

    2002-01-01

    An open cooling circuit for a gas turbine bucket wherein the bucket has an airfoil portion, and a tip shroud, the cooling circuit including a plurality of radial cooling holes extending through the airfoil portion and communicating with an enlarged internal area within the tip shroud before exiting the tip shroud such that a cooling medium used to cool the airfoil portion is subsequently used to cool the tip shroud.

  16. A very cool cooling system

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The NA62 Gigatracker is a jewel of technology: its sensor, which delivers the time of the crossing particles with a precision of less than 200 picoseconds (better than similar LHC detectors), has a cooling system that might become the precursor to a completely new detector technique.   The 115 metre long vacuum tank of the NA62 experiment. The NA62 Gigatracker (GTK) is composed of a set of three innovative silicon pixel detectors, whose job is to measure the arrival time and the position of the incoming beam particles. Installed in the heart of the NA62 detector, the silicon sensors are cooled down (to about -20 degrees Celsius) by a microfluidic silicon device. “The cooling system is needed to remove the heat produced by the readout chips the silicon sensor is bonded to,” explains Alessandro Mapelli, microsystems engineer working in the Physics department. “For the NA62 Gigatracker we have designed a cooling plate on top of which both the silicon sensor and the...

  17. Cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, Todd R; Vyas, Brijesh; Kota, Krishna; Simon, Elina

    2017-01-31

    An apparatus and a method are provided. Use is made of a wick structure configured to receive a liquid and generate vapor in when such wick structure is heated by heat transferred from heat sources to be cooled off. A vapor channel is provided configured to receive the vapor generated and direct said vapor away from the wick structure. In some embodiments, heat conductors are used to transfer the heat from the heat sources to the liquid in the wick structure.

  18. Turbine Blade Cooling System Optimization

    OpenAIRE

    GIRARDEAU, Julian; PAILHES, Jérôme; SEBASTIAN, Patrick; PARDO, Frédéric; Nadeau, Jean-Pierre

    2013-01-01

    The authors wish to thank turbine designers from TURBOMECA SAFRAN Group.; International audience; Designing high performance cooling systems suitable for preserving the service lifetime of nozzle guide vanes of turboshaft engines leads to significant aerodynamic losses. These losses jeopardize the performance of the whole engine. In the same time, a low efficiency cooling system may affect the costs of maintenance repair and overhaul of the engine as component life decreases. Consequently, de...

  19. Cooling of Neutron Stars

    Directory of Open Access Journals (Sweden)

    Grigorian H.

    2010-10-01

    Full Text Available We introduce the theoretical basis for modeling the cooling evolution of compact stars starting from Boltzmann equations in curved space-time. We open a discussion on observational verification of different neutron star models by consistent statistics. Particular interest has the question of existence of quark matter deep inside of compact object, which has to have a specific influence on the cooling history of the star. Besides of consideration of several constraints and features of cooling evolution, which are susceptible of being critical for internal structure of hot compact stars we have introduced a method of extraction of the mass distribution of the neutron stars from temperature and age data. The resulting mass distribution has been compared with the one suggested by supernove simulations. This method can be considered as an additional checking tool for the consistency of theoretical modeling of neutron stars. We conclude that the cooling data allowed existence of neutron stars with quark cores even with one-flavor quark matter.

  20. Computational fluid dynamics model for predicting flow of viscous fluids in a large fermentor with hydrofoil flow impellers and internal cooling coils

    Science.gov (United States)

    Kelly; Humphrey

    1998-03-01

    Considerable debate has occurred over the use of hydrofoil impellers in large-scale fermentors to improve mixing and mass transfer in highly viscous non-Newtonian systems. Using a computational fluid dynamics software package (Fluent, version 4.30) extensive calculations were performed to study the effect of impeller speed (70-130 rpm), broth rheology (value of power law flow behavior index from 0.2 to 0.6), and distance between the cooling coil bank and the fermentor wall (6-18 in.) on flow near the perimeter of a large (75-m3) fermentor equipped with A315 impellers. A quadratic model utilizing the data was developed in an attempt to correlate the effect of A315 impeller speed, power law flow behavior index, and distance between the cooling coil bank and the fermentor wall on the average axial velocity in the coil bank-wall region. The results suggest that there is a potential for slow or stagnant flow in the coil bank-wall region which could result in poor oxygen and heat transfer for highly viscous fermentations. The results also indicate that there is the potential for slow or stagnant flow in the region between the top impeller and the gas headspace when flow through the coil bank-wall region is slow. Finally, a simple guideline was developed to allow fermentor design engineers to predict the degree of flow behind a bank of helical cooling coils in a large fermentor with hydrofoil flow impellers.

  1. 极高分辨变包含角平面光栅单色器关键技术及检测方法研究%Key technologies and the performance measuring methods in variable included angle plane grating monochromator

    Institute of Scientific and Technical Information of China (English)

    卢启鹏; 宋源; 龚学鹏; 马磊

    2016-01-01

    变包含角平面光栅单色器具有分辨率高和光通量高等优点,被广泛应用于各科研领域,并且随着相关领域研究的不断深入,迫切需要提高其光谱分辨率,以满足使用需求。为研究探索极高分辨率变包含角平面光栅单色器,结合上海同步辐射光源光束线,重点研究影响单色器分辨率的关键因素;对单色器光学元件表面热负载进行分析,设计冷却系统,降低热负载产生的影响;研究变包含角平面光栅单色器转角精度等检测方法。结果表明,根据推导出的变包含角平面光栅单色器光学放大倍数与单色器分辨率的关系式,达到优选极高分辨率工作模式的目的;加入冷却系统后,单色器前置平面镜因受热负载影响而产生的最大斜率误差由8.1μrad降到3.1μrad;设计可应用于变包含角光栅单色器分辨率达5×104的转角精度检测方法,检测精度可达0.026″。该研究将为第三代同步辐射光源中建造极高分辨变包含角单色器提供帮助。%The variable-included-angle plane grating monochromator is broadly used in high performance soft X-ray due to its superior performance,such as high throughput and high resolution.With the development of Science,improving and optimizing the resolution of variables-included-angle plane grating monochromator is necessary and urgently.In order to study and explore the ultra-high resolution of variables-included-angle plane grating monochromator in synchrotron radiation,some issues were researched in this work.Firstly,the relationship between working modes of variables-included-angle plane grating monochromator with different cf is emphatically researched.According to the relationship,the high resolution working modes of the mono-chromator can be selected.Secondly,we studied the effects of high heat load on the optical system by using the simulation software and designed an appropriate cooling system in

  2. ATLAS - Liquid Cooling Systems

    CERN Multimedia

    Bonneau, P.

    1998-01-01

    Photo 1 - Cooling Unit - Side View Photo 2 - Cooling Unit - Detail Manifolds Photo 3 - Cooling Unit - Rear View Photo 4 - Cooling Unit - Detail Pump, Heater and Exchanger Photo 5 - Cooling Unit - Detail Pump and Fridge Photo 6 - Cooling Unit - Front View

  3. Optimization of bent perfect Si(220)-crystal monochromator for residual strain/stress instrument-Part II

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Myung-Kook [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of)]. E-mail: moonmk@kaeri.re.kr; Em, Vyacheslav T. [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Lee, Chang-Hee [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Mikula, Pavol [Nuclear Physics Institute and Research Centre Rez Ltd., 250 68 Rez (Czech Republic); Hong, Kwang-Pyo [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Choi, Young-Hyun [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Cheon, Jong-Kyu [Neutron Beam Application, Korea Atomic Energy Research Institute, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Nam, Uk-Won [Nuclear Physics Institute and Research Centre Rez Ltd., 250 68 Rez (Czech Republic); Kong, Kyung-Nam [Nuclear Physics Institute and Research Centre Rez Ltd., 250 68 Rez (Czech Republic); Korea Astronomy Observatory, Yusung, Daejeon 305-348 (Korea, Republic of); Jin, Kyung-Chan [Korea Institute of Industrial Technology, 35-3 Hongchon-Ri, Ipchang-Myun, Chonan-Si, Chungnam, 330-825 (Korea, Republic of)

    2005-11-01

    Optimized diffractometer arrangements for residual strain measurements employing curved crystal monochromators provide good luminosity and a high {delta}d/d resolution in the vicinity of usually used scattering angle 2{theta}{sub S}{approx}+/-90{sup o}. Due to a variety of designs of the diffractometers which could be installed at a constant or different take-off angles, except a few attempts, there is a lack of experimental evidence providing a help in a choice of parameters for an optimum performance. In addition to our earlier investigations with curved Si(311) monochromator employed in different diffraction geometries (see paper I [M.K. Moon et al., Physica B, submitted [1

  4. All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

    CERN Document Server

    Stoupin, S; Blank, V D; Shvyd'ko, Yu V; Goetze, K; Assoufid, L; Polyakov, S N; Kuznetsov, M S; Kornilov, N V; Katsoudas, J; Alonso-Mori, R; Chollet, M; Feng, Y; Glownia, J M; Lemke, H; Robert, A; Song, S; Sikorski, M; Zhu, D

    2014-01-01

    A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fabrication, and X-ray characterization of the first and second (300-um-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 X 2 mm2 with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 X 2 mm2 working regions of the crystals.

  5. Quick scanning monochromator for millisecond in situ and in operando X-ray absorption spectroscopy

    Science.gov (United States)

    Müller, O.; Lützenkirchen-Hecht, D.; Frahm, R.

    2015-09-01

    The design and capabilities of a novel Quick scanning Extended X-ray Absorption Fine Structure (QEXAFS) monochromator are presented. The oscillatory movement of the crystal stage is realized by means of a unique open-loop driving scheme operating a direct drive torque motor. The entire drive mechanics are installed inside of a goniometer located on the atmospheric side of the vacuum chamber. This design allows remote adjustment of the oscillation frequency and spectral range, giving complete control of QEXAFS measurements. It also features a real step-scanning mode, which operates without a control loop to prevent induced vibrations. Equipped with Si(111) and Si(311) crystals on a single stage, it facilitates an energy range from 4.0 keV to 43 keV. Extended X-ray absorption fine structure spectra up to k = 14.4 Å-1 have been acquired within 17 ms and X-ray absorption near edge structure spectra covering more than 200 eV within 10 ms. The achieved data quality is excellent as shown by the presented measurements.

  6. Design, Fabrication and Measurement of Ni/Ti Multilayer Used for Neutron Monochromator

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhong; WANG Zhan-Shan; ZHU Jing-Tao; WU Yong-Rong; MU Bao-Zhong; WANG Feng-Li; QIN Shu-Ji; CHEN Ling-Yan

    2007-01-01

    Ni/Ti multilayers.which can be used for neutron monochromators,are designed,fabricated and measured.Firstly,their reflectivities are simulated based on the Nevot-Croce model.Reflectivities of two Ni/Ti multilayer mirrors with periods d=10.3nm(M1)and d=7.8nm(M2) are calculated.In the calculation,the reflectivity of the Ni/Ti multilayer is taken as a function of the gazing angle with different roughness factors δ=1.0nm and δ=1.5nm.Secondly,these two multilayers are fabricated by the direct current magnetron sputtering technology.Thirdly their structures are characterized by small-angle x-ray diffraction.The roughness factors are fitted to be O.68nm and 1.16nm for M1 and M2.respectively.Finally their reflective performances are measured on the V14 neutron beam line at the Bedin Neutron Scattering Centre(BENSC),Germany.The experimental data show that the grazing angle of the reflected neutron intensity peak increases,but the reflected neutron intensity decreases.with the decreasing periods of the multilayers.

  7. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Science.gov (United States)

    Kristiansen, Paw; Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim

    2015-01-01

    The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged. PMID:26134790

  8. Mechanical design aspects of a soft X-ray plane grating monochromator

    CERN Document Server

    Vasina, R; Dolezel, P; Mynar, M; Vondracek, M; Chab, V; Slezak, J A; Comicioli, C; Prince, K C

    2001-01-01

    A plane grating monochromator based on the SX-700 concept has been constructed for the Materials Science Beamline, Elettra, which is attached to a bending magnet. The tuning range is from 35 to 800 eV with calculated spectral resolving power epsilon/DELTA epsilon better than 4000 in the whole range. The optical elements consist of a toroidal prefocusing mirror, polarization aperture, entrance slit, plane pre-mirror, single plane grating (blazed), spherical mirror, exit slit and toroidal refocusing mirror. The plane grating is operated in the fixed focus mode with C sub f sub f =2.4. Energy scanning is performed by rotation of the plane grating and simultaneous translation and rotation of the plane pre-mirror. A novel solution is applied for the motion of the plane pre-mirror, namely by a translation and mechanically coupling the rotation by a cam. The slits have no moving parts in vacuum to reduce cost and increase ruggedness, and can be fully closed without risk of damage. In the first tests, a resolving pow...

  9. Cool visitors

    CERN Multimedia

    2006-01-01

    Pictured, from left to right: Tim Izo (saxophone, flute, guitar), Bobby Grant (tour manager), George Pajon (guitar). What do the LHC and a world-famous hip-hop group have in common? They are cool! On Saturday, 1st July, before their appearance at the Montreux Jazz Festival, three members of the 'Black Eyed Peas' came on a surprise visit to CERN, inspired by Dan Brown's Angels and Demons. At short notice, Connie Potter (Head of the ATLAS secretariat) organized a guided tour of ATLAS and the AD 'antimatter factory'. Still curious, lead vocalist Will.I.Am met CERN physicist Rolf Landua after the concert to ask many more questions on particles, CERN, and the origin of the Universe.

  10. 变包含角平面光栅单色器及其关键技术%The variable included angle plane grating monochromator and the key technology

    Institute of Scientific and Technical Information of China (English)

    陈家华; 薛松; 卢启鹏; 彭忠琦; 邰仁忠; 王勇; 陈明; 吴坤

    2011-01-01

    This article discusses the design of a variable included angle plane grating monochromator (VAPGM) on the soft X-ray spectromicroscopy beam-line at Shanghai Synchrotron Radiation Facility (SSRF).The precision scanning system of sin-bar meets the requirements through resolving the high precision repeatability of mechanical transmission system; the inner path water cooling structure of the plane mirror controls the thermal deformation of the mirror surface; the huge dimension and quadrate flange chamber ensures the ultra high vacuum (UHV) which the VAPGM requires.Finally, the main capabilities of the monochromator, including the energy range, energy resolution and energy repeatability, reach the design requirements completely.%分析设计并研制了上海光源软X射线谱学显微光束线站的变包含角平面光栅单色器,经过精密加工调试,保证了扫描系统的转角重复精度;采用多孔腔内部通道水冷方法,控制了镜子表面热变形;完成真空箱体大尺寸方法兰加工与密封,达到了单色器工作所需的超高真空.通过上述关键部件的精确掌控,确保了单色器主要性能--光子能量范围、能量分辨率和能量重复性,均优于设计指标.

  11. The impact of the weather conditions on the cooling performance of the heat pump driven by an internal natural gas combustion engine

    Directory of Open Access Journals (Sweden)

    Janovcová Martina

    2015-01-01

    Full Text Available Market with sources of heat and cold offers unlimited choice of different power these devices, design technology, efficiency and price categories. New progressive technologies are constantly discovering, about which is still little information, which include heat pumps powered by a combustion engine running on natural gas. A few pieces of these installations are in Slovakia, but no studies about their work and effectiveness under real conditions. This article deals with experimental measurements of gas heat pump efficiency in cooling mode. Since the gas heat pump works only in system air – water, air is the primary low – energy source, it is necessary to monitor the impact of the climate conditions for the gas heat pump performance.

  12. Turbulence and cooling in cluster cores

    CERN Document Server

    Banerjee, Nilanjan

    2014-01-01

    We study the interplay between turbulent heating, mixing, and radiative cooling in an idealized model of cool cluster cores. Active galactic nuclei (AGN) jets are expected to drive turbulence and heat cluster cores. Cooling of the intracluster medium (ICM) and stirring by AGN jets are tightly coupled in a feedback loop. We impose the feedback loop by balancing radiative cooling with turbulent heating. In addition to heating the plasma, turbulence also mixes it, suppressing the formation of cold gas at small scales. In this regard, the effect of turbulence is analogous to thermal conduction. For uniform plasma in thermal balance (turbulent heating balancing radiative cooling), cold gas condenses only if the cooling time is shorter than the mixing time. This condition requires the turbulent kinetic energy to be $\\gtrsim$ the plasma internal energy; such high velocities in cool cores are ruled out by observations. The results with realistic magnetic fields and thermal conduction are qualitatively similar to the ...

  13. Beryllium, zinc and lead single crystals as a thermal neutron monochromators

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Habib, N. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Bashter, I.I. [Physics Department, Faculty of Science, Zagazig University (Egypt); Morcos, H.N.; El-Mesiry, M.S. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Mansy, M.S., E-mail: drmohamedmansy88@hotmail.com [Physics Department, Faculty of Science, Zagazig University (Egypt)

    2015-03-15

    Highlights: •Monochromatic features of Be, Zn and Pb single crystals. •Calculations of neutron reflectivity using a computer program MONO. •Optimum mosaic spread, thickness and cutting plane of single crystals. -- Abstract: The monochromatic features of Be, Zn and Pb single crystals are discussed in terms of orientation, mosaic spread, and thickness within the wavelength band from 0.04 up to 0.5 nm. A computer program MONO written in “FORTRAN-77”, has been adapted to carry out the required calculations. Calculations show that a 5 mm thick of beryllium (HCP structure) single crystal cut along its (0 0 2) plane having 0.6° FWHM are the optimum parameters when it is used as a monochromator with high reflected neutron intensity from a thermal neutron flux. Furthermore, at wavelengths shorter than 0.16 nm it is free from the accompanying higher order ones. Zinc (HCP structure) has the same parameters, with intensity much less than the latter. The same features are seen with lead (FCC structure) cut along its (3 1 1) plane with less reflectivity than the former. However, Pb (3 1 1) is more preferable than others at neutron wavelengths ⩽ 0.1 nm, since the glancing angle (θ ∼ 20°) is more suitable to carry out diffraction experiments. For a cold neutron flux, the first-order neutrons reflected from beryllium is free from the higher orders up to 0.36 nm. While for Zn single crystal is up to 0.5 nm.

  14. New high-brightness monochrome monitor based on color CRT technology

    Science.gov (United States)

    Spekowius, Gerhard; Weibrecht, Martin; D'Adda, Carlo; Antonini, Antonio; Casale, Carlo; Blume, Hartwig R.

    1997-05-01

    With increasing availability of medical image communication infrastructures, medical images are more and more displayed as soft-copies rather than as hard-copies. Often however, the image viewing environment is characterized by high ambient light, such as in surgery rooms or offices illuminated by daylight. We are describing a very-high- brightness cathode-ray-tube (CRT) monitor which accommodates these viewing conditions without the typical deterioration in resolution due to electron focal spot blooming. The three guns of a standard color CRT are used to create a high brightness monochrome monitor. The CRT has no shadow-mask, and a homogeneous P45 phosphor layer has been deposited instead of the structured red-green-blue color phosphor screen. The electron spots of the three guns are dynamically matched by applying appropriate waveforms to four additional multiple magnetic fields around the gun assembly. We evaluated the image quality of the triple-gun CRT monitor concerning parameters which are especially relevant for medical imaging applications. We have measured characteristic curves, dynamic range, veiling glare, resolution, spot profiles, and screen noise. The monitor can provide a high luminance of more than 200 fL. Due to nearly perfect matching of the three spots, the resolution is mainly determined by the beam profile of a single gun and is remarkably high even at these high luminance values. The P45 phosphor shows very little structure noise, which is an advantage for medical desktop applications. Since all relevant monitor parameters are digitally controlled, the status of the monitor can be fully characterized at any time. This feature particularly facilitates the reproduction of brightness and contrast values and hence allows easy implementation of a display function standard or to return to a desired display function that has been found useful for a given application in the past.

  15. Soil-Structure Interaction Analysis of Jack-up Platforms Subjected to Monochrome and Irregular Waves

    Institute of Scientific and Technical Information of China (English)

    Maziar Gholami KORZANI; Ali Akbar AGHAKOUCHAK

    2015-01-01

    As jack-up platforms have recently been used in deeper and harsher waters, there has been an increasing demand to understand their behaviour more accurately to develop more sophisticated analysis techniques. One of the areas of significant development has been the modelling of spudcan performance, where the load-displacement behaviour of the foundation is required to be included in any numerical model of the structure. In this study, beam on nonlinear winkler foundation (BNWF) modeling—which is based on using nonlinear springs and dampers instead of a continuum soil media—is employed for this purpose. A regular monochrome design wave and an irregular wave representing a design sea state are applied to the platform as lateral loading. By using the BNWF model and assuming a granular soil under spudcans, properties such as soil nonlinear behaviour near the structure, contact phenomena at the interface of soil and spudcan (such as uplifting and rocking), and geometrical nonlinear behaviour of the structure are studied. Results of this study show that inelastic behaviour of the soil causes an increase in the lateral displacement at the hull elevation and permanent unequal settlement in soil below the spudcans, which are increased by decreasing the friction angle of the sandy soil. In fact, spudcans and the underlying soil cause a relative fixity at the platform support, which changes the dynamic response of the structure compared with the case where the structure is assumed to have a fixed support or pinned support. For simulating this behaviour without explicit modelling of soil-structure interaction (SSI), moment-rotation curves at the end of platform legs, which are dependent on foundation dimensions and soil characteristics, are obtained. These curves can be used in a simplified model of the platform for considering the relative fixity at the soil-foundation interface.

  16. Conceptual design description for the tritium recovery system for the US ITER (International Thermonuclear Experimental Reactor) Li sub 2 O/Be water cooled blanket

    Energy Technology Data Exchange (ETDEWEB)

    Finn, P.A.; Sze, D.K. (Argonne National Lab., IL (USA). Fusion Power Program); Clemmer, R.G. (Pacific Northwest Lab., Richland, WA (USA))

    1990-11-01

    The tritium recovery system for the US ITER Li{sub 2}O/Be water cooled blanket processes two separate helium purge streams to recover tritium from the Li{sub 2}O zones and the Be zones of the blanket, to process the waste products, and to recirculate the helium back to the blanket. The components are selected to minimize the tritium inventory of the recovery system, and to minimize waste products. The system is robust to either an increase in the tritium release rate or to an in-leak of water in the purge system. Three major components were used to process these streams, first, 5A molecular sieves at {minus}196{degree}C separate hydrogen from the helium, second, a solid oxide electrolysis unit is used to reduce all molecular water, and third, a palladium/silver diffuser is used to ensure that only hydrogen (H{sub 2}, HT) species reach the cryogenic distillation unit. Other units are present to recover tritium from waste products but the three major components are the basis of the blanket tritium recovery system. 32 refs.

  17. Experimental and numerical investigations of internal heat transfer in an innovative trailing edge blade cooling system: stationary and rotation effects, part 1—experimental results

    Science.gov (United States)

    Beniaiche, Ahmed; Ghenaiet, Adel; Facchini, Bruno

    2017-02-01

    The aero-thermal behavior of the flow field inside 30:1 scaled model reproducing an innovative smooth trailing edge of shaped wedge discharge duct with one row of enlarged pedestals have been investigated in order to determine the effect of rotation, inlet velocity and blowing conditions effects, for Re = 20,000 and 40,000 and Ro = 0-0.23. Two configurations are presented: with and without open tip configurations. Thermo-chromic liquid crystals technique is used to ensure a local measurement of the heat transfer coefficient on the blade suction side under stationary and rotation conditions. Results are reported in terms of detailed 2D HTC maps on the suction side surface as well as the averaged Nusselt number inside the pedestal ducts. Two correlations are proposed, for both closed and open tip configurations, based on the Re, Pr, Ro and a new non-dimensional parameter based on the position along the radial distance, to assess a reliable estimation of the averaged Nusselt number at the inter-pedestal region. A good agreement is found between prediction and experimental data with about ±10 to ±12 % of uncertainty, for the simple form correlation, and about ±16 % using a complex form. The obtained results help to predict the flow field visualization and the evaluation of the aero-thermal performance of the studied blade cooling system during the design step.

  18. Experimental and numerical investigations of internal heat transfer in an innovative trailing edge blade cooling system: stationary and rotation effects, part 2: numerical results

    Science.gov (United States)

    Beniaiche, Ahmed; Ghenaiet, Adel; Carcasci, Carlo; Facchini, Bruno

    2017-02-01

    This paper presents a numerical validation of the aero-thermal study of a 30:1 scaled model reproducing an innovative trailing edge with one row of enlarged pedestals under stationary and rotating conditions. A CFD analysis was performed by means of commercial ANSYS-Fluent modeling the isothermal air flow and using k- ω SST turbulence model and an isothermal air flow for both static and rotating conditions (Ro up to 0.23). The used numerical model is validated first by comparing the numerical velocity profiles distribution results to those obtained experimentally by means of PIV technique for Re = 20,000 and Ro = 0-0.23. The second validation is based on the comparison of the numerical results of the 2D HTC maps over the heated plate to those of TLC experimental data, for a smooth surface for a Reynolds number = 20,000 and 40,000 and Ro = 0-0.23. Two-tip conditions were considered: open tip and closed tip conditions. Results of the average Nusselt number inside the pedestal ducts region are presented too. The obtained results help to predict the flow field visualization and the evaluation of the aero-thermal performance of the studied blade cooling system during the design step.

  19. Performance of synchrotron X-ray monochromators under heat load Part 1 finite element modeling

    CERN Document Server

    Zhang, L; Migliore, J S; Mocella, V; Ferrero, C; Freund, A K

    2001-01-01

    In this paper we present the details of the finite element modeling (FEM) procedure used to calculate the thermal deformation generated by the X-ray power absorbed in silicon crystals. Different parameters were varied systematically such as the beam footprint on the crystal, the reflection order and the white beam slit settings. Moreover, the influence of various cooling parameters such as the cooling coefficient and the temperature of the coolant were studied. The finite element meshing was carefully optimized to generate a deformation output that could be easily read by a diffraction simulation code. Comparison with the experiments shows that the peak-to-valley slope error calculated by the FEM is an excellent approximation of the rocking curve width for a liquid nitrogen cooled silicon (3 3 3) crystal, and a quite good approximation for significantly deformed silicon (1 1 1) crystals.

  20. A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

    Energy Technology Data Exchange (ETDEWEB)

    Tokurei, Shogo, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan and Department of Radiology, Yamaguchi University Hospital, 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Morishita, Junji, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582 (Japan)

    2015-08-15

    Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors

  1. Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Martinson, Mercedes, E-mail: mercedes.m@usask.ca [University of Saskatchewan, 116 Science Place, Room 163, Saskatoon, Saskatchewan (Canada); Samadi, Nazanin [University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan (Canada); Belev, George [Canadian Light Source, 44 Innovation Boulevard, Saskatoon, Saskatchewan (Canada); Bassey, Bassey [University of Saskatchewan, 116 Science Place, Room 163, Saskatoon, Saskatchewan (Canada); Lewis, Rob [University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan (Canada); Monash University, Clayton, Victoria 3800 (Australia); Aulakh, Gurpreet [University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan (Canada); Chapman, Dean [University of Saskatchewan, 116 Science Place, Room 163, Saskatoon, Saskatchewan (Canada); University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan (Canada)

    2014-03-13

    A bent Laue beam-expanding double-crystal monochromator was developed and tested at the Biomedical Imaging and Therapy beamline at the Canadian Light Source. The expander will reduce scanning time for micro-computed tomography and allow dynamic imaging that has not previously been possible at this beamline. The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vertical beam is desirable. It was cost-prohibitive to build a longer beamline that would have produced a large vertical beam. Instead, it was proposed to develop a beam expander that would create a beam appearing to originate at a source much farther away. This was accomplished using a bent Laue double-crystal monochromator in a non-dispersive divergent geometry. The design and implementation of this beam expander is presented along with results from the micro-CT and dynamic imaging tests conducted with this beam. Flux (photons per unit area per unit time) has been measured and found to be comparable with the existing flat Bragg double-crystal monochromator in use at BMIT. This increase in overall photon count is due to the enhanced bandwidth of the bent Laue configuration. Whilst the expanded beam quality is suitable for dynamic imaging and micro-CT, further work is required to improve its phase and coherence properties.

  2. Characterization of InGaN/GaN quantum well growth using monochromated valence electron energy loss spectroscopy

    OpenAIRE

    Palisaitis, J.; Lundskog, A.; Forsberg, U.; Janzén, E.; Birch, J.; Hultman, L.; Persson, P. O. Å.

    2014-01-01

    The early stages of InGaN/GaN quantum wells growth for In reduced conditions have been investigated for varying thickness and composition of the wells. The structures were studied by monochromated STEM–VEELS spectrum imaging at high spatial resolution. It is found that beyond a critical well thickness and composition, quantum dots (>20 nm) are formed inside the well. These are buried by compositionally graded InGaN, which is formed as GaN is grown while residual In is incorporated into the...

  3. Replacement of monochromator and proportional gas counter by mercuric iodide detector in X-ray powder diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Nissenbaum, J.; Levi, A.; Burger, A.; Schieber, M. (Hebrew Univ., Jerusalem (Israel). School of Applied Science and Technology)

    1983-02-01

    Low resolution and therefore low-cost mercuric iodide detectors have successfully been applied to replace the combination of a graphite monochromator and a proportional gas radiation counter used in X-ray diffractometers. The mercuric iodide detector requires a lower DC bias of only 200 V rather than the 1500 V bias needed for the proportional gas counter. The much better stopping power of HgI/sub 2/ allows higher counting efficiency and therefore a better signal-to-noise ratio. Results are shown for X-ray powder diffractions of polycrystalline cubic silicon and tetragonal HgI/sub 2/.

  4. Holographically recorded ion-etched varied line spacing grating for a monochromator at the Photon Factory BL19B

    CERN Document Server

    Fujisawa, M; Shin, S

    2001-01-01

    Holographically recorded, ion etched ruled gratings can be obtained for the varied line spacing plane grating (VPG) monochromator at the Photon Factory BL19B. A new holographic recording method makes it possible to manufacture VPGs with large varied line coefficients for reducing the aberration terms in the optical path function. The efficiency at higher photon energies and the quantity of stray light are improved in comparison with mechanically ruled gratings. The calculation shows that the much lower efficiency at higher photon energies is not intrinsic for saw-tooth type gratings. It seems to be caused instead by carbon contamination, radiation damage, deformation at manufacturing and so on.

  5. Low pressure cooling seal system for a gas turbine engine

    Science.gov (United States)

    Marra, John J

    2014-04-01

    A low pressure cooling system for a turbine engine for directing cooling fluids at low pressure, such as at ambient pressure, through at least one cooling fluid supply channel and into a cooling fluid mixing chamber positioned immediately downstream from a row of turbine blades extending radially outward from a rotor assembly to prevent ingestion of hot gases into internal aspects of the rotor assembly. The low pressure cooling system may also include at least one bleed channel that may extend through the rotor assembly and exhaust cooling fluids into the cooling fluid mixing chamber to seal a gap between rotational turbine blades and a downstream, stationary turbine component. Use of ambient pressure cooling fluids by the low pressure cooling system results in tremendous efficiencies by eliminating the need for pressurized cooling fluids for sealing this gap.

  6. Broadband optical cooling of molecular rotors

    CERN Document Server

    Lien, Chien-Yu; Odom, Brian C

    2014-01-01

    Contrary to intuition, resonant laser excitation of bound electrons can decrease the temperature of a system, with electronic relaxation times as fast as nanoseconds allowing for rapid cooling to far below ambient temperature. Although laser cooling of atoms is routine owing to their relatively simple internal structure, laser cooling of molecular translational speeds, vibrations, or rotations is challenging because a different laser frequency is required to electronically excite each populated vibrational and rotational state. Here, we show that molecules with decoupled vibrational and electronic modes can be rotationally cooled using a single spectrally filtered broadband laser to simultaneously address many rotational states. We optically cool AlH$^+$ ions held in a room-temperature radiofrequency Paul trap to collect 96% of the population in the ground quantum state, corresponding to a rotational temperature of 4 K. In our current implementation, parity-preserving electronic cycling cools to the two lowes...

  7. The MICE Demonstration of Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Pasternak, J.; Blackmore, V.; Hunt, C.; Lagrange, J-B.; Long, K.; Collomb, N.; Snopok, P.

    2015-05-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions at energies of up to several TeV at the Muon Collider. The International Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization cooling channel, the muon beam passes through a material (the absorber) in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised project plan, which has received the formal endorsement of the international MICE Project Board and the international MICE Funding Agency Committee, will deliver a demonstration of ionization cooling by September 2017. In the revised configuration a central lithium-hydride absorber provides the cooling effect. The magnetic lattice is provided by the two superconducting focus coils and acceleration is provided by two 201 MHz single-cavity modules. The phase space of the muons entering and leaving the cooling cell will be measured by two solenoidal spectrometers. All the superconducting magnets for the ionization cooling demonstration are available at the Rutherford Appleton Laboratory and the first single-cavity prototype is under test in the MuCool Test Area at Fermilab. The design of the cooling demonstration experiment will be described together with a summary of the performance of each of its components. The cooling performance of the revised configuration will also be presented.

  8. Enhancing the efectiveness of film cooling

    Institute of Scientific and Technical Information of China (English)

    Tom I-P.Shih; Sangkwon Na

    2007-01-01

    Advanced gas turbine stages are designed to operate at increasingly higher inlet temperatures to increase thermal efficiency and specific power output.To maintain durability and reasonable life,film cooling is needed in addition to internal cooling,especially for the first stage.Film cooling lowers material temperature by forced convection inside film-cooling holes and by forming a layer of coolant about component surfaces to insulate them from the hot gases.Unfortunately,each cooling jet forms a pair of counter-rotating vortices that entrains hot gas and causes the film-cooling jet to lift off from the surface that it is intended to protect.This paper gives an overview of efforts to enhance the effectiveness of film-cooling.This paper also describes two new design concepts.One design concept seeks to minimize the entrainment of hot gases underneath of film-cooling jets by using flow-aligned blockers.The other design concept shifts the interaction between the approaching hot gas and the cooling jet to occur further above the surface by using an upstream ramp.For both design concepts,computational fluid dynamics results are presented to examine their usefulness in enhancing film-cooling effectiveness.

  9. Optimization of the bent perfect Si(311)-crystal monochromator for a residual strain/stress instrument at the HANARO reactor-Part I

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Myung-Kook [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of)]. E-mail: moonmk@kaeri.re.kr; Lee, Chang-Hee [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Em, Vyacheslav T. [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Mikula, Pavol [Nuclear Physics Institute and Research Centre Rez, Ltd., 250 68 Rez (Czech Republic); Hong, Kwang-Pyo [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Choi, Young-Hyun [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Cheon, Jong-Kyu [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Choi, Young-Nam [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Kim, Shin-Ae [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Kim, Sung-Kyu [Korea Atomic Energy Research Institute, Neutron Beam Application, 150 Duckjin-Dong, Yusung, Daejon 305-600 (Korea, Republic of); Jin, Kyung-Chan [Korea Institute of Industrial Technology 35-3 Hongchon-Ri, Ipchang-Myun, Chonan-Si, Chungnam 330-825 (Korea, Republic of)

    2005-12-01

    Reflectivity and resolution properties of a variety of optimized focusing monochromator performances based on cylindrically bent perfect Si-crystals were tested with the aim of evaluating their possible use in a strain/stress diffractometer. It has been found that the optimized monochromator performances of the curved Si(311) crystals (for the take-off angle 2{theta}{sub M}=60 deg.) provide a good luminosity and a sufficiently high resolution (full width at half maximum (FWHM) of the instrumental {delta}d/d-profile can be about 2x10{sup -3} in the vicinity of the lattice spacing d=0.117nm for 2{theta}{sub S}{approx}90 deg.) of the strain/stress diffractometer with the figure of merit more than one order of magnitude larger than that related to the conventional flat mosaic Ge(220) monochromator of {eta}=15{sup '}.

  10. The future of CO2 cooling in particle physics detectors

    NARCIS (Netherlands)

    B. Verlaat; A.P. Colijn; H. Postema

    2011-01-01

    Evaporative CO2 cooling has attracted a lot of interest as cooling fluid for particle physics detectors. Two detectors (the AMS on the International Space Station and the LHCb at the Large Hadron Collider at CERN) have been equipped with CO2 cooling; many more particle detectors are considering it f

  11. Hybrid radiator cooling system

    Science.gov (United States)

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  12. Wake monochromator in asymmetric and symmetric Bragg and Laue geometry for self-seeding the European X-ray FEL

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni; Serkez, Svitozar; Tolkiehn, Martin

    2013-01-01

    We discuss the use of self-seeding schemes with wake monochromators to produce TW power, fully coherent pulses for applications at the dedicated bio-imaging bealine at the European X-ray FEL, a concept for an upgrade of the facility beyond the baseline previously proposed by the authors. We exploit the asymmetric and symmetric Bragg and Laue reflections (sigma polarization) in diamond crystal. Optimization of the bio-imaging beamline is performed with extensive start-to-end simulations, which also take into account effects such as the spatio-temporal coupling caused by the wake monochromator. The spatial shift is maximal in the range for small Bragg angles. A geometry with Bragg angles close to pi/2 would be a more advantageous option from this viewpoint, albeit with decrease of the spectral tunability. We show that it will be possible to cover the photon energy range from 3 keV to 13 keV by using four different planes of the same crystal with one rotational degree of freedom.

  13. Wake monochromator in asymmetric and symmetric Bragg and Laue geometry for self-seeding the European X-ray FEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni; Serkez, Svitozar; Tolkiehn, Martin [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2013-01-15

    We discuss the use of self-seeding schemes with wake monochromators to produce TW power, fully coherent pulses for applications at the dedicated bio-imaging beamline at the European X-ray FEL, a concept for an upgrade of the facility beyond the baseline previously proposed by the authors. We exploit the asymmetric and symmetric Bragg and Laue reflections (sigma polarization) in diamond crystal. Optimization of the bio-imaging beamline is performed with extensive start-to-end simulations, which also take into account effects such as the spatio-temporal coupling caused by the wake monochromator. The spatial shift is maximal in the range for small Bragg angles. A geometry with Bragg angles close to {pi}/2 would be a more advantageous option from this viewpoint, albeit with decrease of the spectral tunability. We show that it will be possible to cover the photon energy range from 3 keV to 13 keV by using four different planes of the same crystal with one rotational degree of freedom.

  14. Mesh sensitivity in the thermal analysis of a gas turbine a blade with internal cooling; Sensibilidad de malla en el analisis termico de un alabe de turbina de gas con enfriamiento interno

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro Ayala, Jorge Arturo; Gallegos Munoz, Armando [Facultad de Ingenieria Mecanica, Electrica y Electronica (FIMEE), Universidad de Guanajuato (Mexico); Campos Amezcua, Alfonso [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-11-15

    This article presents the methodology to generate the mesh model of the computer model of a blade by means of commands in the software of CFD Fluent, mainly in the fluid zone, since a mesh sensitivity analysis becomes too expensive in terms of human and computer resources. When geometry is too irregular, modifications are required in the mesh to avoid problems such as the divergence, instability in the solution and the dependency on the results of temperature, pressure, velocity, etc. Such is the case of a blade with internal cooling of the first stage of a gas turbine. The results are included of the generated mesh as well as of the thermal analysis of the blade. Additionally the results of temperature, pressure and velocity of the combustion gases and of the cooling air are shown. [Spanish] Este articulo presenta la metodologia para generar el mallado del modelo computacional de un alabe por medio de comandos en el software de CFD Fluent, principalmente en la zona del fluido, ya que un analisis de sensibilidad de malla se vuelve demasiado costoso en terminos de recursos humanos y computacionales. Cuando la geometria es demasiado irregular, se requiere de modificaciones en la malla para evitar problemas como son la divergencia, inestabilidad en la solucion y la dependencia de los resultados de temperatura, presion, velocidad, etc. Tal es el caso de un alabe con enfriamiento interno de la primera etapa de una turbina de gas. Se incluyen los resultados tanto de la malla generada como del analisis termico del alabe. Adicionalmente se muestran los resultados de temperatura, presion y velocidad de los gases de la combustion y del aire de enfriamiento.

  15. A medium-resolution monochromator for 73 keV x-rays - Nuclear resonant scattering of synchrotron radiation from 193-Ir

    CERN Document Server

    Alexeev, Pavel; Wille, Hans-Christian; Sergeev, Ilya; Herlitschke, Marcus; Leupold, Olaf; McMorrow, Desmond F; Röhlsberger, Ralf

    2016-01-01

    We report on the development and characterization of a medium resolution monochromator for synchrotron-based hyperfine spectroscopy at the 73 keV nuclear resonance of 193-Ir. The device provides high throughput of 6*10^8 ph/s in an energy bandwidth of 300(20) meV. We excited the nuclear resonance in 193-Ir at 73.04 keV and observed nuclear fluorescence of 193-Ir in Iridium metal. The monochromator allows for Nuclear Forward Scattering spectroscopy on Ir and its compounds.

  16. Grackle: Chemistry and radiative cooling library for astrophysical simulations

    Science.gov (United States)

    Smith, Britton D.; Bryan, Greg L.; Glover, Simon C. O.; Goldbaum, Nathan J.; Turk, Matthew J.; Regan, John; Wise, John H.; Schive, Hsi-Yu; Abel, Tom; Emerick, Andrew; O'Shea, Brian W.; Anninos, Peter; Hummels, Cameron B.; Khochfar, Sadegh

    2016-12-01

    The chemistry and radiative cooling library Grackle provides options for primordial chemistry and cooling, photo-heating and photo-ionization from UV backgrounds, and support for user-provided arrays of volumetric and specific heating rates for astrophysical simulations and models. The library provides functions to update chemistry species; solve radiative cooling and update internal energy; and calculate cooling time, temperature, pressure, and ratio of specific heats (gamma), and has interfaces for C, C++, Fortran, and Python codes.

  17. Inelastic analysis of the deformation behaviour of internally cooled IN 738 LC turbine blades using the microstructural dependent constitutive equations; Inelastische Analyse des Verformungsverhaltens einer innengekuehlten Gasturbinenschaufel aus dem Werkstoff IN 738 LC unter Verwendung des strukturabhaengigen Werkstoffmodells

    Energy Technology Data Exchange (ETDEWEB)

    Beckmoeller, S.; Schubert, F.; Penkalla, H.J.; Nickel, H.; Breitbach, G.

    1994-06-01

    To enhance the high temperature potential of Superalloys for applications in stationary gas turbines a new concept is required for the prediction of the service life of the blades with an improved method for inelastic analysis. The applicability of the microstructural dependent constitutive equations, which has been developed at the IWE of the KFA, are discussed for a structural analysis of an internally cooled IN 738 LC turbine blade. For the multiaxial confirmation of the model tension-torsion experiments and experiments with precision casted internally cooled model turbine blades were carried out. The blades were exposed to temperature transients and tension stresses to simulate the centrifugal forces. For the mathematical analysis the constitutive equations were implemented into the Finite Elemente Code ABAQUS. A two dimensional mesh was used. At first, the temperature distribution in the blade was calculated based on the temperatures measured at certain points during the experiments. After the temperature distribution was known, it was possible to calculate the stresses and inelastic strains at every point of the model structure. The comparison of the experiments with the calculations, using the constitutive equations of Penkalla, showed a good conformity. For the life time prediction by experiments with short holding times, an elastic analysis could be used. But for experiments with long holding times creep is more dominant and has to be considered. (orig.) [Deutsch] Fuer die optimale Nutzung der Eigenschaften neuer hochwarmfester Superlegierungen reicht die herkoemmliche Auslegung dann nicht mehr aus, wenn ein Bauteil komplizierten Temperatur- und Belastungszyklen ausgesetzt ist. Die Beurteilung des Betriebsverhaltens und der Lebensdauer solcher Bauteile bedarf neuer Konzepte. Ein solches Bauteil ist die innengekuehlte Turbinenschaufel einer modernen stationaeren Gasturbine. Im Rahmen dieser Arbeit wurde die Anwendbarkeit des strukturabhaengigen

  18. Recent Development in Turbine Blade Film Cooling

    Directory of Open Access Journals (Sweden)

    Je-Chin Han

    2001-01-01

    Full Text Available Gas turbines are extensively used for aircraft propulsion, land-based power generation, and industrial applications. Thermal efficiency and power output of gas turbines increase with increasing turbine rotor inlet temperature (RIT. The current RIT level in advanced gas turbines is far above the .melting point of the blade material. Therefore, along with high temperature material development, a sophisticated cooling scheme must be developed for continuous safe operation of gas turbines with high performance. Gas turbine blades are cooled internally and externally. This paper focuses on external blade cooling or so-called film cooling. In film cooling, relatively cool air is injected from the inside of the blade to the outside surface which forms a protective layer between the blade surface and hot gas streams. Performance of film cooling primarily depends on the coolant to mainstream pressure ratio, temperature ratio, and film hole location and geometry under representative engine flow conditions. In the past number of years there has been considerable progress in turbine film cooling research and this paper is limited to review a few selected publications to reflect recent development in turbine blade film cooling.

  19. Fuel Cell Thermal Management Through Conductive Cooling Plates

    Science.gov (United States)

    Colozza, Anthony J.; Burke, Kenneth A.

    2008-01-01

    An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

  20. Liquid-Cooled Garment

    Science.gov (United States)

    1977-01-01

    A liquid-cooled bra, offshoot of Apollo moon suit technology, aids the cancer-detection technique known as infrared thermography. Water flowing through tubes in the bra cools the skin surface to improve resolution of thermograph image.

  1. Data center cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun

    2015-03-17

    A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.

  2. Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD.

    Science.gov (United States)

    Takahashi, Keita; Morishita, Junji; Hiwasa, Takeshi; Hatanaka, Shiro; Sakai, Shuji; Hashimoto, Noriyuki; Nakamura, Yasuhiko; Toyofuku, Fukai; Higashida, Yoshiharu; Ohki, Masafumi

    2010-07-01

    The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m(2)) was compared with the detectability of a monochrome LCD (500 cd/m(2)). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m(2) color LCD, 500 cd/m(2) monochrome LCD, and 170 cd/m(2) color LCD were 0.937 +/- 0.040, 0.924 +/- 0.056, and 0.915 +/- 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m(2) color LCD was significantly shorter than that for the 500 cd/m(2) color and monochrome LCDs (p LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.

  3. First experimental test of a new monochromated and aberration-corrected 200 kV field-emission scanning transmission electron microscope.

    Science.gov (United States)

    Walther, T; Quandt, E; Stegmann, H; Thesen, A; Benner, G

    2006-01-01

    The first 200 kV scanning transmission electron microscope (STEM) with an imaging energy filter, a monochromator and a corrector for the spherical aberration (Cs-corrector) of the illumination system has been built and tested. The STEM/TEM concept with Koehler illumination allows to switch easily between STEM mode for analytical and TEM mode for high-resolution or in situ studies. The Cs-corrector allows the use of large illumination angles for retaining a sufficiently high beam current despite the intensity loss in the monochromator. With the monochromator on and a 3 microm slit in the dispersion plane that gives 0.26 eV full-width at half-maximum (FWHM) energy resolution we have obtained so far an electron beam smaller than 0.20 nm in diameter (FWHM as measured by scanning the spot quickly over the CCD) which contains 7 pA current and, according to simulations, should be around 0.12 nm in true size. A high-angle annular dark field (ADF) image with isotropic resolution better than 0.28 nm has been recorded with the monochromator in the above configuration and the Cs-corrector on. The beam current is still somewhat low for electron energy-loss spectroscopy (EELS) but is expected to increase substantially by optimising the condenser set-up and using a somewhat larger condenser aperture.

  4. First experimental test of a new monochromated and aberration-corrected 200 kV field-emission scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Walther, T. [Center of Advanced European Studies and Research (caesar), Ludwig-Erhard-Allee 2, D-53175 Bonn (Germany)]. E-mail: walther@caesar.de; Quandt, E. [Center of Advanced European Studies and Research (caesar), Ludwig-Erhard-Allee 2, D-53175 Bonn (Germany); Stegmann, H. [Carl Zeiss Nano Technology Systems GmbH, Carl-Zeiss-Str. 56, D-73447 Oberkochen (Germany); Thesen, A. [Carl Zeiss Nano Technology Systems GmbH, Carl-Zeiss-Str. 56, D-73447 Oberkochen (Germany); Benner, G. [Carl Zeiss Nano Technology Systems GmbH, Carl-Zeiss-Str. 56, D-73447 Oberkochen (Germany)

    2006-10-15

    The first 200 kV scanning transmission electron microscope (STEM) with an imaging energy filter, a monochromator and a corrector for the spherical aberration (C {sub s}-corrector) of the illumination system has been built and tested. The STEM/TEM concept with Koehler illumination allows to switch easily between STEM mode for analytical and TEM mode for high-resolution or in situ studies. The C{sub s}-corrector allows the use of large illumination angles for retaining a sufficiently high beam current despite the intensity loss in the monochromator. With the monochromator on and a 3 {mu}m slit in the dispersion plane that gives 0.26 eV full-width at half-maximum (FWHM) energy resolution we have obtained so far an electron beam smaller than 0.20 nm in diameter (FWHM as measured by scanning the spot quickly over the CCD) which contains 7 pA current and, according to simulations, should be around 0.12 nm in true size. A high-angle annular dark field (ADF) image with isotropic resolution better than 0.28 nm has been recorded with the monochromator in the above configuration and the C {sub s}-corrector on. The beam current is still somewhat low for electron energy-loss spectroscopy (EELS) but is expected to increase substantially by optimising the condenser set-up and using a somewhat larger condenser aperture.

  5. Simulated Measurements of Cooling in Muon Ionization Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mohayai, Tanaz [IIT, Chicago; Rogers, Chris [Rutherford; Snopok, Pavel [Fermilab

    2016-06-01

    Cooled muon beams set the basis for the exploration of physics of flavour at a Neutrino Factory and for multi-TeV collisions at a Muon Collider. The international Muon Ionization Cooling Experiment (MICE) measures beam emittance before and after an ionization cooling cell and aims to demonstrate emittance reduction in muon beams. In the current MICE Step IV configuration, the MICE muon beam passes through low-Z absorber material for reducing its transverse emittance through ionization energy loss. Two scintillating fiber tracking detectors, housed in spectrometer solenoid modules upstream and downstream of the absorber are used for reconstructing position and momentum of individual muons for calculating transverse emittance reduction. However, due to existence of non-linear effects in beam optics, transverse emittance growth can be observed. Therefore, it is crucial to develop algorithms that are insensitive to this apparent emittance growth. We describe a different figure of merit for measuring muon cooling which is the direct measurement of the phase space density.

  6. Stochastic cooling in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Brennan,J.M.; Blaskiewicz, M. M.; Severino, F.

    2009-05-04

    After the success of longitudinal stochastic cooling of bunched heavy ion beam in RHIC, transverse stochastic cooling in the vertical plane of Yellow ring was installed and is being commissioned with proton beam. This report presents the status of the effort and gives an estimate, based on simulation, of the RHIC luminosity with stochastic cooling in all planes.

  7. Computational investigation of film cooling from cylindrical and row trenched cooling holes near the combustor endwall

    Directory of Open Access Journals (Sweden)

    Ehsan Kianpour

    2014-11-01

    Full Text Available This study was performed to investigate the effects of cylindrical and row trenched cooling holes with alignment angles of 0° and 90° at blowing ratio of 3.18 on the film cooling performance adjacent to the endwall surface of a combustor simulator. In this research a three-dimensional representation of Pratt and Whitney gas turbine engine was simulated and analyzed with a commercial finite volume package FLUENT 6.2. The analysis has been carried out with Reynolds-Averaged Navier–Stokes turbulence model (RANS on internal cooling passages. This combustor simulator was combined with the interaction of two rows of dilution jets, which were staggered in the streamwise direction and aligned in the spanwise direction. Film cooling was placed along the combustor liner walls. In comparison with the baseline case of cooling holes, the application of a row trenched hole near the endwall surface doubled the performance of film cooling effectiveness.

  8. Interface of the transport systems research vehicle monochrome display system to the digital autonomous terminal access communication data bus

    Science.gov (United States)

    Easley, W. C.; Tanguy, J. S.

    1986-01-01

    An upgrade of the transport systems research vehicle (TSRV) experimental flight system retained the original monochrome display system. The original host computer was replaced with a Norden 11/70, a new digital autonomous terminal access communication (DATAC) data bus was installed for data transfer between display system and host, while a new data interface method was required. The new display data interface uses four split phase bipolar (SPBP) serial busses. The DATAC bus uses a shared interface ram (SIR) for intermediate storage of its data transfer. A display interface unit (DIU) was designed and configured to read from and write to the SIR to properly convert the data from parallel to SPBP serial and vice versa. It is found that separation of data for use by each SPBP bus and synchronization of data tranfer throughout the entire experimental flight system are major problems which require solution in DIU design. The techniques used to accomplish these new data interface requirements are described.

  9. Vibratory response of a precision double-multi-layer monochromator positioning system using a generic modeling program with experimental verification.

    Energy Technology Data Exchange (ETDEWEB)

    Barraza, J.

    1998-07-29

    A generic vibratory response-modeling program has been developed as a tool for designing high-precision optical positioning systems. The systems are modeled as rigid-body structures connected by linear non-rigid elements such as complex actuators and bearings. The full dynamic properties of each non-rigid element are determined experimentally or theoretically, then integrated into the program as inertial and stiffness matrices. Thus, it is possible to have a suite of standardize structural elements for modeling many different positioning systems that use standardized components. This paper will present the application of this program to a double-multi-layer monochromator positioning system that utilizes standardized components. Calculated results are compared to experimental modal analysis results.

  10. Measurement of vibrational spectrum of liquid using monochromated scanning transmission electron microscopy-electron energy loss spectroscopy.

    Science.gov (United States)

    Miyata, Tomohiro; Fukuyama, Mao; Hibara, Akihide; Okunishi, Eiji; Mukai, Masaki; Mizoguchi, Teruyasu

    2014-10-01

    Investigations on the dynamic behavior of molecules in liquids at high spatial resolution are greatly desired because localized regions, such as solid-liquid interfaces or sites of reacting molecules, have assumed increasing importance with respect to improving material performance. In application to liquids, electron energy loss spectroscopy (EELS) observed with transmission electron microscopy (TEM) is a promising analytical technique with the appropriate resolutions. In this study, we obtained EELS spectra from an ionic liquid, 1-ethyl-3-methylimidazolium bis (trifluoromethyl-sulfonyl) imide (C2mim-TFSI), chosen as the sampled liquid, using monochromated scanning TEM (STEM). The molecular vibrational spectrum and the highest occupied molecular orbital (HOMO)-lowest unoccupied molecular orbital (LUMO) gap of the liquid were investigated. The HOMO-LUMO gap measurement coincided with that obtained from the ultraviolet-visible spectrum. A shoulder in the spectrum observed ∼0.4 eV is believed to originate from the molecular vibration. From a separately performed infrared observation and first-principles calculations, we found that this shoulder coincided with the vibrational peak attributed to the C-H stretching vibration of the [C2mim(+)] cation. This study demonstrates that a vibrational peak for a liquid can be observed using monochromated STEM-EELS, and leads one to expect observations of chemical reactions or aids in the analysis of the dynamic behavior of molecules in liquid. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. In-situ metrology for the optimization of bent crystals used in hard-X-ray monochromators: Comparison between measurement and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Thomasset, Muriel, E-mail: muriel.thomasset@synchrotron-soleil.f [Synchrotron SOLEIL, L' orme des Merisiers, BP 48, 91192 Gif sur Yvette (France); Moreno, Thierry; Capitanio, Blandine; Idir, Mourad [Synchrotron SOLEIL, L' orme des Merisiers, BP 48, 91192 Gif sur Yvette (France); Bucourt, Samuel [Imagine Optic, 18 rue Charles de Gaulle, Orsay 91400 (France)

    2010-05-01

    Crystal sagittal focusing is known as one of the most efficient way of focusing synchrotron X-ray radiation from bending magnet sources, thus delivering increases photon flux at the sample position. To optimize the performance of a sagittaly bent crystal inside a monochromator, it is necessary to have knowledge of its radius of curvature. However, this measurement is not very easy to obtain. Even though the use of the X-ray beam is the ultimate source for optimizing the system, it is still necessary to have a prior knowledge of the radius of curvature as a function of the motor bender positions to avoid any catastrophic failure. In this paper, we describe a simple, efficient and accurate method of measuring the radius of curvature of sagitally bent monochromator crystals at several bending magnet beamlines at synchrotron SOLEIL. To optimize the crystal bending inside these monochromators, we used a Shack-Hartmann sensor (HP 26) developed by the Imagine Optic Company (Orsay/France). This high accuracy two-dimensional metrology tool was originally designed to be installed on a Long Trace Profiler translation stage to measure the mirrors profiles. During a period where the SOLEIL synchrotron was in shutdown, this instrument was directly mounted inside the monochromator so that the radius of curvature could be measured in-situ. This method allows us to optimize the curvature and eliminate twist before bending strongly the crystal below radii of curvature of less than 2 m. The second step in the optimization process was to use the X-ray beam for the final adjustments of the bending system, where X-ray images are then used to analyse the residual defaults of the system. Using SpotX, a ray-tracing simulation tool, these errors can be fully analysed and a fully optimized system can then be obtained. Overall, five beamlines at synchrotron SOLEIL have used in this method to optimize their monochromators.

  12. Direct Liquid Cooling for Electronic Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry; Greenberg, Steve

    2014-03-01

    This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used

  13. Laser cooling of solids

    OpenAIRE

    Nemova, Galina

    2009-01-01

    Parallel to advances in laser cooling of atoms and ions in dilute gas phase, which has progressed immensely, resulting in physics Nobel prizes in 1997 and 2001, major progress has recently been made in laser cooling of solids. I compare the physical nature of the laser cooling of atoms and ions with that of the laser cooling of solids. I point out all advantages of this new and very promising area of laser physics. Laser cooling of solids (optical refrigeration) at the present time can be lar...

  14. The MICE Demonstration of Muon Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, Jean-Baptiste [Imperial Coll., London; Hunt, Christopher [Imperial Coll., London; Palladino, Vittorio [INFN, Naples; Pasternak, Jaroslaw [Imperial Coll., London

    2016-06-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions up to several TeV at the Muon Collider. The international Muon Ionization Cooling Experiment (MICE) will demonstrate muon ionization cooling, the technique proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam traverses a material (the absorber) loosing energy, which is replaced using RF cavities. The combined effect is to reduce the transverse emittance of the beam (transverse cooling). The configuration of MICE required to deliver the demonstration of ionization cooling is being prepared in parallel to the execution of a programme designed to measure the cooling properties of liquid-hydrogen and lithium hydride. The design of the cooling-demonstration experiment will be presented together with a summary of the performance of each of its components and the cooling performance of the experiment.

  15. Stochastic cooling in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Brennan J. M.; Blaskiewicz, M.; Mernick, K.

    2012-05-20

    The full 6-dimensional [x,x'; y,y'; z,z'] stochastic cooling system for RHIC was completed and operational for the FY12 Uranium-Uranium collider run. Cooling enhances the integrated luminosity of the Uranium collisions by a factor of 5, primarily by reducing the transverse emittances but also by cooling in the longitudinal plane to preserve the bunch length. The components have been deployed incrementally over the past several runs, beginning with longitudinal cooling, then cooling in the vertical planes but multiplexed between the Yellow and Blue rings, next cooling both rings simultaneously in vertical (the horizontal plane was cooled by betatron coupling), and now simultaneous horizontal cooling has been commissioned. The system operated between 5 and 9 GHz and with 3 x 10{sup 8} Uranium ions per bunch and produces a cooling half-time of approximately 20 minutes. The ultimate emittance is determined by the balance between cooling and emittance growth from Intra-Beam Scattering. Specific details of the apparatus and mathematical techniques for calculating its performance have been published elsewhere. Here we report on: the method of operation, results with beam, and comparison of results to simulations.

  16. Status of cool roof standards in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen

    2007-06-01

    Since 1999, several widely used building energy efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool roof credits or requirements. We review the technical development of cool roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discuss the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool roof provisions can be used as models to address cool roofs in building energy standards worldwide.

  17. Cooling by Thermodynamic Induction

    Science.gov (United States)

    Patitsas, S. N.

    2017-03-01

    A method is described for cooling conductive channels to below ambient temperature. The thermodynamic induction principle dictates that the electrically biased channel will cool if the electrical conductance decreases with temperature. The extent of this cooling is calculated in detail for both cases of ballistic and conventional transport with specific calculations for carbon nanotubes and conventional metals, followed by discussions for semiconductors, graphene, and metal-insulator transition systems. A theorem is established for ballistic transport stating that net cooling is not possible. For conventional transport, net cooling is possible over a broad temperature range, with the range being size-dependent. A temperature clamping scheme for establishing a metastable nonequilibrium stationary state is detailed and followed with discussion of possible applications to on-chip thermoelectric cooling in integrated circuitry and quantum computer systems.

  18. Cooling by Thermodynamic Induction

    Science.gov (United States)

    Patitsas, S. N.

    2016-11-01

    A method is described for cooling conductive channels to below ambient temperature. The thermodynamic induction principle dictates that the electrically biased channel will cool if the electrical conductance decreases with temperature. The extent of this cooling is calculated in detail for both cases of ballistic and conventional transport with specific calculations for carbon nanotubes and conventional metals, followed by discussions for semiconductors, graphene, and metal-insulator transition systems. A theorem is established for ballistic transport stating that net cooling is not possible. For conventional transport, net cooling is possible over a broad temperature range, with the range being size-dependent. A temperature clamping scheme for establishing a metastable nonequilibrium stationary state is detailed and followed with discussion of possible applications to on-chip thermoelectric cooling in integrated circuitry and quantum computer systems.

  19. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  20. Initial Cooling Experiment (ICE)

    CERN Multimedia

    Photographic Service

    1978-01-01

    In 1977, in a record-time of 9 months, the magnets of the g-2 experiment were modified and used to build a proton/antiproton storage ring: the "Initial Cooling Experiment" (ICE). It served for the verification of the cooling methods to be used for the "Antiproton Project". Stochastic cooling was proven the same year, electron cooling followed later. Also, with ICE the experimental lower limit for the antiproton lifetime was raised by 9 orders of magnitude: from 2 microseconds to 32 hours. For its previous life as g-2 storage ring, see 7405430. More on ICE: 7711282, 7809081, 7908242.

  1. High energy electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Parkhomchuk, V. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation)

    1997-09-01

    High energy electron cooling requires a very cold electron beam. The questions of using electron cooling with and without a magnetic field are presented for discussion at this workshop. The electron cooling method was suggested by G. Budker in the middle sixties. The original idea of the electron cooling was published in 1966. The design activities for the NAP-M project was started in November 1971 and the first run using a proton beam occurred in September 1973. The first experiment with both electron and proton beams was started in May 1974. In this experiment good result was achieved very close to theoretical prediction for a usual two component plasma heat exchange.

  2. Power electronics cooling apparatus

    Science.gov (United States)

    Sanger, Philip Albert; Lindberg, Frank A.; Garcen, Walter

    2000-01-01

    A semiconductor cooling arrangement wherein a semiconductor is affixed to a thermally and electrically conducting carrier such as by brazing. The coefficient of thermal expansion of the semiconductor and carrier are closely matched to one another so that during operation they will not be overstressed mechanically due to thermal cycling. Electrical connection is made to the semiconductor and carrier, and a porous metal heat exchanger is thermally connected to the carrier. The heat exchanger is positioned within an electrically insulating cooling assembly having cooling oil flowing therethrough. The arrangement is particularly well adapted for the cooling of high power switching elements in a power bridge.

  3. Evolution of cool-roof standards in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Akbari, Hashem; Levinson, Ronnen

    2008-07-11

    Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

  4. Sympathetic cooling of molecules with laser-cooled atoms

    Science.gov (United States)

    Hudson, Eric

    2014-05-01

    Cooling molecules through collisions with laser-cooled atoms is an attractive route to ultracold, ground state molecules. The technique is simple, applicable to a wide class of molecules, and does not require molecule specific laser systems. Particularly suited to this technique are charged molecules, which can be trapped indefinitely, even at room temperature, and undergo strong, short-ranged collisions with ultracold atoms. In this talk, I will focus on recent efforts to use the combination of a magneto-optical trap (MOT) and an ion trap, dubbed the MOTion trap, to produce cold, ground state diatomic charged molecules. The low-energy internal structure of these diatomic molecules, e.g. the electric dipole moment and vibrational, rotational, and Ω-doublet levels, presents a host of opportunities for advances in quantum simulation, precision measurement, cold chemistry, and quantum information. Excitingly, recent proof-of-principle experiments have demonstrated that the MOTion trap is extremely efficient at cooling the vibrational motion of molecular ions. Supported by the ARO and NSF.

  5. Cooling off with physics

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Chris [Unilever R and D (United Kingdom)

    2003-08-01

    You might think of ice cream as a delicious treat to be enjoyed on a sunny summer's day. However, to the ice-cream scientists who recently gathered in Thessaloniki in Greece for the 2nd International Ice Cream Symposium, it is a complex composite material. Ice cream consists of three dispersed phases: ice crystals, which have a mean size of 50 microns, air bubbles with a diameter of about 70 microns, and fat droplets with a size of 1 micron. These phases are held together by what is called the matrix - not a sci-fi film, but a viscous solution of sugars, milk proteins and polysaccharides. The microstructure, and hence the texture that you experience when you eat ice cream, is created in a freezing process that has remained fundamentally unchanged since the first ice-cream maker was patented in the 1840s. The ingredients - water, milk protein, fat, sugar, emulsifiers, stabilizers, flavours and a lot of air - are mixed together before being pasteurized and homogenized. They are then pumped into a cylinder that is cooled from the outside with a refrigerant. As the mixture touches the cylinder wall it freezes and forms ice crystals, which are quickly scraped off by a rotating blade. The blade is attached to a beater that disperses the ice crystals into the mixture. At the same time, air is injected and broken down into small bubbles by the shear that the beater generates. As the mixture passes along the cylinder, the number of ice crystals increases and its temperature drops. As a result, the viscosity of the mixture increases, so that more energy input is needed to rotate the beater. This energy is dissipated as heat, and when the ice cream reaches about -6 deg. C the energy input through the beater equals the energy removed as heat by the refrigerant. The process therefore becomes self-limiting and it is not possible to cool the ice cream any further. However, at -6 deg. C the microstructure is unstable. The ice cream therefore has to be removed from the freezer

  6. Statistics Analysis Measures Painting of Cooling Tower

    Directory of Open Access Journals (Sweden)

    A. Zacharopoulou

    2013-01-01

    Full Text Available This study refers to the cooling tower of Megalopolis (construction 1975 and protection from corrosive environment. The maintenance of the cooling tower took place in 2008. The cooling tower was badly damaged from corrosion of reinforcement. The parabolic cooling towers (factory of electrical power are a typical example of construction, which has a special aggressive environment. The protection of cooling towers is usually achieved through organic coatings. Because of the different environmental impacts on the internal and external side of the cooling tower, a different system of paint application is required. The present study refers to the damages caused by corrosion process. The corrosive environments, the application of this painting, the quality control process, the measures and statistics analysis, and the results were discussed in this study. In the process of quality control the following measurements were taken into consideration: (1 examination of the adhesion with the cross-cut test, (2 examination of the film thickness, and (3 controlling of the pull-off resistance for concrete substrates and paintings. Finally, this study refers to the correlations of measurements, analysis of failures in relation to the quality of repair, and rehabilitation of the cooling tower. Also this study made a first attempt to apply the specific corrosion inhibitors in such a large structure.

  7. Cooling Load Distribution of Large Space Building

    Institute of Scientific and Technical Information of China (English)

    CHEN Hong-bing(陈红兵); TU Guang-bei(涂光备); YANG Jie(杨洁); Chan K T

    2003-01-01

    The cooling and heating load distribution of large area air-conditioned room such as "open" offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is not the case in reality, and a low efficient air conditioning system results from this assumption. A simulation and analysis of the cooling load distribution of an office building in Hong Kong with TRANSYS software is provided in this paper. A typical office is divided into 13 zones for simulation, including external zone, medial zone and internal zone in the north, the south, the east and the west respectively and a central zone, instead of 4 directional zone. The result shows there is much cooling load difference between each zone, and more attention should be paid to uneven indoor cooling and heating load distribution to further guide the design.

  8. Application of inductively coupled plasma atomic emission spectroscopy analysis with a polychromator/monochromator combination the byproducts of coal-fired power stations

    Science.gov (United States)

    Weers, C. A.

    The by-products of coal-fired power plants may be hazardous for the environment. Good analysis methods are therefore required in order to establish either a possible usage of the by-products or their possible storage. Preliminary experiments performed with inductively coupled plasma atomic emission spectroscopy have proven very successful. Moreover, the method is cost-effective. A short description is given of the optimized system for routine analysis. The system consists of a 2- and a 15-channel polychromator in combination with a monochromator. The opportunities is provides are also described. Use of the monochromator to analyze coal and run-off water from the flue-gases desulphurization, and of the polychromators to analyze coal fly-ash is described separately.

  9. A possibility of parallel and anti-parallel diffraction measurements on neutron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition

    Indian Academy of Sciences (India)

    Yong Nam Choi; Shin Ae Kim; Sung Kyu Kim; Sung Baek Kim; Chang-Hee Lee; Pivel Mikula

    2004-07-01

    In a conventional diffractometer having single monochromator, only one position, parallel position, is used for the diffraction experiment (i.e. detection) because the resolution property of the other one, anti-parallel position, is very poor. However, a bent perfect crystal (BPC) monochromator at monochromatic focusing condition can provide a quite flat and equal resolution property at both parallel and anti-parallel positions and thus one can have a chance to use both sides for the diffraction experiment. From the data of the FWHM and the / measured on three diffraction geometries (symmetric, asymmetric compression and asymmetric expansion), we can conclude that the simultaneous diffraction measurement in both parallel and anti-parallel positions can be achieved.

  10. Elastocaloric cooling: Stretch to actively cool

    Science.gov (United States)

    Ossmer, Hinnerk; Kohl, Manfred

    2016-10-01

    The elastocaloric effect can be exploited in solid-state cooling technologies as an alternative to conventional vapour compression. Now, an elastocaloric device based on the concept of active regeneration achieves a temperature lift of 15.3 K and efficiencies competitive with other caloric-based approaches.

  11. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  12. The final cool down

    CERN Multimedia

    Thursday 29th May, the cool-down of the final sector (sector 4-5) of LHC has begun, one week after the start of the cool-down of sector 1-2. It will take five weeks for the sectors to be cooled from room temperature to 5 K and a further two weeks to complete the cool down to 1.9 K and the commissioning of cryogenic instrumentation, as well as to fine tune the cryogenic plants and the cooling loops of cryostats.Nearly a year and half has passed since sector 7-8 was cooled for the first time in January 2007. For Laurent Tavian, AT/CRG Group Leader, reaching the final phase of the cool down is an important milestone, confirming the basic design of the cryogenic system and the ability to operate complete sectors. “All the sectors have to operate at the same time otherwise we cannot inject the beam into the machine. The stability and reliability of the cryogenic system and its utilities are now very important. That will be the new challenge for the coming months,” he explains. The status of the cool down of ...

  13. Solar absorption cooling

    NARCIS (Netherlands)

    Kim, D.-S.

    2007-01-01

    As the world concerns more and more on global climate changes and depleting energy resources, solar cooling technology receives increasing interests from the public as an environment-friendly and sustainable alternative. However, making a competitive solar cooling machine for the market still

  14. Passive evaporative cooling

    NARCIS (Netherlands)

    Tzoulis, A.

    2011-01-01

    This "designers' manual" is made during the TIDO-course AR0531 Smart & Bioclimatic Design. Passive techniques for cooling are a great way to cope with the energy problem of the present day. This manual introduces passive cooling by evaporation. These methods have been used for many years in traditi

  15. Data center cooling method

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Dang, Hien P.; Parida, Pritish R.; Schultz, Mark D.; Sharma, Arun

    2015-08-11

    A method aspect for removing heat from a data center may use liquid coolant cooled without vapor compression refrigeration on a liquid cooled information technology equipment rack. The method may also include regulating liquid coolant flow to the data center through a range of liquid coolant flow values with a controller-apparatus based upon information technology equipment temperature threshold of the data center.

  16. Liquid Cooled Garments

    Science.gov (United States)

    1979-01-01

    Astronauts working on the surface of the moon had to wear liquid-cooled garments under their space suits as protection from lunar temperatures which sometimes reach 250 degrees Fahrenheit. In community service projects conducted by NASA's Ames Research Center, the technology developed for astronaut needs has been adapted to portable cooling systems which will permit two youngsters to lead more normal lives.

  17. Solar absorption cooling

    NARCIS (Netherlands)

    Kim, D.-S.

    2007-01-01

    As the world concerns more and more on global climate changes and depleting energy resources, solar cooling technology receives increasing interests from the public as an environment-friendly and sustainable alternative. However, making a competitive solar cooling machine for the market still remain

  18. Coherent electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko,V.

    2009-05-04

    Cooling intense high-energy hadron beams remains a major challenge in modern accelerator physics. Synchrotron radiation is still too feeble, while the efficiency of two other cooling methods, stochastic and electron, falls rapidly either at high bunch intensities (i.e. stochastic of protons) or at high energies (e-cooling). In this talk a specific scheme of a unique cooling technique, Coherent Electron Cooling, will be discussed. The idea of coherent electron cooling using electron beam instabilities was suggested by Derbenev in the early 1980s, but the scheme presented in this talk, with cooling times under an hour for 7 TeV protons in the LHC, would be possible only with present-day accelerator technology. This talk will discuss the principles and the main limitations of the Coherent Electron Cooling process. The talk will describe the main system components, based on a high-gain free electron laser driven by an energy recovery linac, and will present some numerical examples for ions and protons in RHIC and the LHC and for electron-hadron options for these colliders. BNL plans a demonstration of the idea in the near future.

  19. Modeling gasodynamic vortex cooling

    Science.gov (United States)

    Allahverdyan, A. E.; Fauve, S.

    2017-08-01

    We aim at studying gasodynamic vortex cooling in an analytically solvable, thermodynamically consistent model that can explain limitations on the cooling efficiency. To this end, we study an angular plus radial flow between two (coaxial) rotating permeable cylinders. Full account is taken of compressibility, viscosity, and heat conductivity. For a weak inward radial flow the model qualitatively describes the vortex cooling effect, in terms of both temperature and the decrease of the stagnation enthalpy, seen in short uniflow vortex (Ranque) tubes. The cooling does not result from external work and its efficiency is defined as the ratio of the lowest temperature reached adiabatically (for the given pressure gradient) to the lowest temperature actually reached. We show that for the vortex cooling the efficiency is strictly smaller than 1, but in another configuration with an outward radial flow, we find that the efficiency can be larger than 1. This is related to both the geometry and the finite heat conductivity.

  20. Hydronic rooftop cooling systems

    Science.gov (United States)

    Bourne, Richard C.; Lee, Brian Eric; Berman, Mark J.

    2008-01-29

    A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

  1. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1979-01-01

    ICE was built in 1977, using the modified bending magnets of the g-2 muon storage ring (see 7405430). Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project. Stochastic cooling proved a resounding success early in 1978 and the antiproton project could go ahead, now entirely based on stochastic cooling. Electron cooling was experimented with in 1979. The 26 kV equipment is housed in the cage to the left of the picture, adjacent to the "e-cooler" located in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7809081.

  2. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1978-01-01

    ICE was built in 1977, in a record time of 9 months, using the modified bending magnets of the g-2 muon storage ring. Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project, to be launched in 1978. Already early in 1978, stochastic cooling proved a resounding success, such that the antiproton (p-pbar)project was entirely based on it. Tests of electron cooling followed later: protons of 46 MeV kinetic energy were cooled with an electron beam of 26 kV and 1.3 A. The cage seen prominently in the foreground houses the HV equipment, adjacent to the "cooler" installed in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7908242.

  3. Rotational cooling of trapped polyatomic molecules

    CERN Document Server

    Glöckner, Rosa; Englert, Barbara G U; Rempe, Gerhard; Zeppenfeld, Martin

    2015-01-01

    Controlling the internal degrees of freedom is a key challenge for applications of cold and ultracold molecules. Here, we demonstrate rotational-state cooling of trapped methyl fluoride molecules (CH3F) by optically pumping the population of 16 M-sublevels in the rotational states J=3,4,5, and 6 into a single level. By combining rotational-state cooling with motional cooling, we increase the relative number of molecules in the state J=4, K=3, M=4 from a few percent to over 70%, thereby generating a translationally cold (~30mK) and nearly pure state ensemble of about 10^6 molecules. Our scheme is extendable to larger sets of initial states, other final states and a variety of molecule species, thus paving the way for internal-state control of ever larger molecules.

  4. Global Cooling: Policies to Cool the World and Offset Global Warming from CO2 Using Reflective Roofs and Pavements

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Rosenfeld, Arthur; Elliot, Matthew

    2009-08-28

    Increasing the solar reflectance of the urban surface reduce its solar heat gain, lowers its temperatures, and decreases its outflow of thermal infrared radiation into the atmosphere. This process of 'negative radiative forcing' can help counter the effects of global warming. In addition, cool roofs reduce cooling-energy use in air conditioned buildings and increase comfort in unconditioned buildings; and cool roofs and cool pavements mitigate summer urban heat islands, improving outdoor air quality and comfort. Installing cool roofs and cool pavements in cities worldwide is a compelling win-win-win activity that can be undertaken immediately, outside of international negotiations to cap CO{sub 2} emissions. We propose an international campaign to use solar reflective materials when roofs and pavements are built or resurfaced in temperate and tropical regions.

  5. 中子单色器模拟分析研究%Simulation and Analysis of Spectrum Selection Affected by Neutron Monochromator's Parameters

    Institute of Scientific and Technical Information of China (English)

    霍合勇; 唐科; 唐彬; 刘斌; 曹超

    2014-01-01

    为研究单色器对中子能谱的选择规律,本文利用MCSTAS程序模拟分析了机械速度选择器与晶体单色器几个特征参数对中子能量选择影响。分析结果显示经机械速度选择器单色选择中子注量率要下降1~2个量级,而晶体单色器要下降2~3个量级。因此,对于单色化要求比较高选用晶体单色器,对于实验时间要求较高的选用机械速度选择器。%To comprehend the selective rule of monochromator for neutron spectrum , the paper analyzes the effects of several characteristic parameters on neutron energy selection .The simulated results indicate that ve-locity selector could get high neutron flux , whose energy width -broadening becomes larger along with selected neutron peak wavelength , and crystal monochromator could get high energy resolution , whose energy width -broadening becomes narrower along with selected neutron peak wavelength .So it is suggested that crystal mono-chromator can be selected if high energy resolution is required , and mechanical velocity selector can be used if high neutron flux is required .

  6. Radiant Heating and Cooling Systems. Part two

    DEFF Research Database (Denmark)

    Kim, Kwan Woo; Olesen, Bjarne W.

    2015-01-01

    Control of the heating and cooling system needs to be able to maintain the indoor temperatures within the comfort range under the varying internal loads and external climates. To maintain a stable thermal environment, the control system needs to maintain the balance between the heat gain...

  7. Second sector cool down

    CERN Multimedia

    2007-01-01

    At the beginning of July, cool-down is starting in the second LHC sector, sector 4-5. The cool down of sector 4-5 may occasionally generate mist at Point 4, like that produced last January (photo) during the cool-down of sector 7-8.Things are getting colder in the LHC. Sector 7-8 has been kept at 1.9 K for three weeks with excellent stability (see Bulletin No. 16-17 of 16 April 2007). The electrical tests in this sector have got opt to a successful start. At the beginning of July the cryogenic teams started to cool a second sector, sector 4-5. At Point 4 in Echenevex, where one of the LHC’s cryogenic plants is located, preparations for the first phase of the cool-down are underway. During this phase, the sector will first be cooled to 80 K (-193°C), the temperature of liquid nitrogen. As for the first sector, 1200 tonnes of liquid nitrogen will be used for the cool-down. In fact, the nitrogen circulates only at the surface in the ...

  8. Measuring the coolness of interactive products: the COOL questionnaire

    DEFF Research Database (Denmark)

    Bruun, Anders; Raptis, Dimitrios; Kjeldskov, Jesper;

    2016-01-01

    is the COOL questionnaire. We based the creation of the questionnaire on literature suggesting that perceived coolness is decomposed to outer cool (the style of a product) and inner cool (the personality characteristics assigned to it). In this paper, we focused on inner cool, and we identified 11 inner cool......, rebelliousness and usability. These factors and their underlying 16 question items comprise the COOL questionnaire. The whole process of creating the questionnaire is presented in detail in this paper and we conclude by discussing our work against related work on coolness and HCI....

  9. Cool WISPs for stellar cooling excesses

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, Maurizio [Barry Univ., Miami Shores, FL (United States). Physical Sciences; Irastorza, Igor [Zaragoza Univ. (Spain). Dept. de Fisica Teorica; Redondo, Javier [Zaragoza Univ. (Spain). Dept. de Fisica Teorica; Max-Planck-Institut fuer Physik, Muenchen (Germany); Ringwald, Andreas [DESY Hamburg (Germany). Theory Group

    2015-12-15

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a preference for a mild non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP represents the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO.

  10. Cool WISPs for stellar cooling excesses

    CERN Document Server

    Giannotti, Maurizio; Redondo, Javier; Ringwald, Andreas

    2015-01-01

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a preference for a mild non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP represents the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO.

  11. Water-cooled electronics

    CERN Document Server

    Dumont, G; Righini, B

    2000-01-01

    LHC experiments demand on cooling of electronic instrumentation will be extremely high. A large number of racks will be located in underground caverns and counting rooms, where cooling by conventional climatisation would be prohibitively expensive. A series of tests on the direct water cooling of VMEbus units and of their standard power supplies is reported. A maximum dissipation of 60 W for each module and more than 1000 W delivered by the power supply to the crate have been reached. These values comply with the VMEbus specifications. (3 refs).

  12. Broadband Optical Cooling of Molecular Rotors

    Science.gov (United States)

    Lien, Chien-Yu

    Laser cooling of atoms is a widely utilized technique in scientific research, and has been developed over more than three decades. Recently, optically controlling and manipulating the external and internal degrees of freedom of molecules has aroused wide interest in the physics and chemistry communities. However, owing to the more complicated internal structure of molecules, laser cooling of molecules is still underdeveloped. Here we demonstrate cooling the rotation of trapped molecular ions from room temperature to 4 K. The molecule of interest, AlH+, is co-trapped and sympathetically cooled with Ba+ to milliKelvin temperatures in its translational degree of freedom. The nearly diagonal Franck-Condon-Factors between the electronic X and A states of AlH+ create semi-closed cycling transitions between the vibrational ground states of X and A states. A spectrally filtered femtosecond laser is used to optically pump the population to the two lowest rotational levels, with opposite parities, in as little as 100 mus by driving the A-X transition. In addition, a cooling scheme including vibrational relaxation brings the population to the N=0positive-parity level on the order of 100 ms. The population distribution among the rotational levels is detected by resonance-enhanced multiphoton dissociation (REMPD) and time-of-flight mass-spectrometry (TOFMS). This technique opens new avenues to many further studies such as high-precision molecular quantum logic spectroscopy (mQLS) and fundamental constant measurements.

  13. Cooling Devices in Laser therapy.

    Science.gov (United States)

    Das, Anupam; Sarda, Aarti; De, Abhishek

    2016-01-01

    Cooling devices and methods are now integrated into most laser systems, with a view to protecting the epidermis, reducing pain and erythema and improving the efficacy of laser. On the basis of method employed, it can be divided into contact cooling and non-contact cooling. With respect to timing of irradiation of laser, the nomenclatures include pre-cooling, parallel cooling and post-cooling. The choice of the cooling device is dictated by the laser device, the physician's personal choice with respect to user-friendliness, comfort of the patient, the price and maintenance costs of the device. We hereby briefly review the various techniques of cooling, employed in laser practice.

  14. Efficient sympathetic motional ground-state cooling of a molecular ion

    CERN Document Server

    Wan, Yong; Wolf, Fabian; Schmidt, Piet O

    2015-01-01

    Cold molecular ions are promising candidates in various fields ranging from precision spectroscopy and test of fundamental physics to ultra-cold chemistry. Control of internal and external degrees of freedom is a prerequisite for many of these applications. Motional ground state cooling represents the starting point for quantum logic-assisted internal state preparation, detection, and spectroscopy protocols. Robust and fast cooling is crucial to maximize the fraction of time available for the actual experiment. We optimize the cooling rate of ground state cooling schemes for single $^{25}\\mathrm{Mg}^{+}$ ions and sympathetic ground state cooling of $^{24}\\mathrm{MgH}^{+}$. In particular, we show that robust cooling is achieved by combining pulsed Raman sideband cooling with continuous quench cooling. Furthermore, we experimentally demonstrate an efficient strategy for ground state cooling outside the Lamb-Dicke regime.

  15. LHC cooling gains ground

    CERN Multimedia

    Huillet-Miraton Catherine

    The nominal cryogenic conditions of 1.9 K have been achieved in sectors 5-6 and 7-8. This means that a quarter of the machine has reached the nominal conditions for LHC operation, having attained a temperature of below 2 K (-271°C), which is colder than interstellar space! Elsewhere, the cryogenic system in Sector 8-1 has been filled with liquid helium and cooled to 2K and will soon be available for magnet testing. Sectors 6-7 and 2-3 are being cooled down and cool-down operations have started in Sector 3-4. Finally, preparations are in hand for the cool-down of Sector 1-2 in May and of Sector 4-5, which is currently being consolidated. The LHC should be completely cold for the summer. For more information: http://lhc.web.cern.ch/lhc/Cooldown_status.htm.

  16. Why Exercise Is Cool

    Science.gov (United States)

    ... to Know About Puberty Train Your Temper Why Exercise Is Cool KidsHealth > For Kids > Why Exercise Is ... day and your body will thank you later! Exercise Makes Your Heart Happy You may know that ...

  17. Waveguide cooling system

    Science.gov (United States)

    Chen, B. C. J.; Hartop, R. W.

    1981-04-01

    An improved system is described for cooling high power waveguides by the use of cooling ducts extending along the waveguide, which minimizes hot spots at the flanges where waveguide sections are connected together. The cooling duct extends along substantially the full length of the waveguide section, and each flange at the end of the section has a through hole with an inner end connected to the duct and an opposite end that can be aligned with a flange hole in another waveguide section. Earth flange is formed with a drainage groove in its face, between the through hole and the waveguide conduit to prevent leakage of cooling fluid into the waveguide. The ducts have narrowed sections immediately adjacent to the flanges to provide room for the installation of fasteners closely around the waveguide channel.

  18. Warm and Cool Dinosaurs.

    Science.gov (United States)

    Mannlein, Sally

    2001-01-01

    Presents an art activity in which first grade students draw dinosaurs in order to learn about the concept of warm and cool colors. Explains how the activity also helped the students learn about the concept of distance when drawing. (CMK)

  19. Cooling of wood briquettes

    Directory of Open Access Journals (Sweden)

    Adžić Miroljub M.

    2013-01-01

    Full Text Available This paper is concerned with the experimental research of surface temperature of wood briquettes during cooling phase along the cooling line. The cooling phase is an important part of the briquette production technology. It should be performed with care, otherwise the quality of briquettes could deteriorate and possible changes of combustion characteristics of briquettes could happen. The briquette surface temperature was measured with an IR camera and a surface temperature probe at 42 sections. It was found that the temperature of briquette surface dropped from 68 to 34°C after 7 minutes spent at the cooling line. The temperature at the center of briquette, during the 6 hour storage, decreased to 38°C.

  20. Stacking with stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Caspers, Fritz E-mail: Fritz.Caspers@cern.ch; Moehl, Dieter

    2004-10-11

    Accumulation of large stacks of antiprotons or ions with the aid of stochastic cooling is more delicate than cooling a constant intensity beam. Basically the difficulty stems from the fact that the optimized gain and the cooling rate are inversely proportional to the number of particles 'seen' by the cooling system. Therefore, to maintain fast stacking, the newly injected batch has to be strongly 'protected' from the Schottky noise of the stack. Vice versa the stack has to be efficiently 'shielded' against the high gain cooling system for the injected beam. In the antiproton accumulators with stacking ratios up to 10{sup 5} the problem is solved by radial separation of the injection and the stack orbits in a region of large dispersion. An array of several tapered cooling systems with a matched gain profile provides a continuous particle flux towards the high-density stack core. Shielding of the different systems from each other is obtained both through the spatial separation and via the revolution frequencies (filters). In the 'old AA', where the antiproton collection and stacking was done in one single ring, the injected beam was further shielded during cooling by means of a movable shutter. The complexity of these systems is very high. For more modest stacking ratios, one might use azimuthal rather than radial separation of stack and injected beam. Schematically half of the circumference would be used to accept and cool new beam and the remainder to house the stack. Fast gating is then required between the high gain cooling of the injected beam and the low gain stack cooling. RF-gymnastics are used to merge the pre-cooled batch with the stack, to re-create free space for the next injection, and to capture the new batch. This scheme is less demanding for the storage ring lattice, but at the expense of some reduction in stacking rate. The talk reviews the 'radial' separation schemes and also gives some

  1. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...... is considered as extruded profiles are inadequate for compact designs. An optimal pin fin shape and configuration is sought also taking manufacturing costs into consideration. Standard methods for geometrical modeling and thermal analysis are applied....

  2. Anomalous law of cooling

    OpenAIRE

    Lapas, Luciano C.; Ferreira, Rogelma M. S.; Oliveira, Fernando A.; Rubí, J. Miguel

    2014-01-01

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergo a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature ma...

  3. Cooling tower waste reduction

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, S.J.; Celeste, J.; Chine, R.; Scott, C.

    1998-05-01

    At Lawrence Livermore National Laboratory (LLNL), the two main cooling tower systems (central and northwest) were upgraded during the summer of 1997 to reduce the generation of hazardous waste. In 1996, these two tower systems generated approximately 135,400 lbs (61,400 kg) of hazardous sludge, which is more than 90 percent of the hazardous waste for the site annually. At both, wet decks (cascade reservoirs) were covered to block sunlight. Covering the cascade reservoirs reduced the amount of chemical conditioners (e.g. algaecide and biocide), required and in turn the amount of waste generated was reduced. Additionally, at the northwest cooling tower system, a sand filtration system was installed to allow cyclical filtering and backflushing, and new pumps, piping, and spray nozzles were installed to increase agitation. the appurtenance upgrade increased the efficiency of the cooling towers. The sand filtration system at the northwest cooling tower system enables operators to continuously maintain the cooling tower water quality without taking the towers out of service. Operational costs (including waste handling and disposal) and maintenance activities are compared for the cooling towers before and after upgrades. Additionally, the effectiveness of the sand filter system in conjunction with the wet deck covers (northwest cooling tower system), versus the cascade reservoir covers alone (south cooling tower south) is discussed. the overall expected return on investment is calculated to be in excess of 250 percent. this upgrade has been incorporated into the 1998 DOE complex-wide water conservation project being led by Sandia National Laboratory/Albuquerque.

  4. Cooling with Superfluid Helium

    CERN Document Server

    Lebrun, P

    2014-01-01

    The technical properties of helium II (‘superfluid’ helium) are presented in view of its applications to the cooling of superconducting devices, particularly in particle accelerators. Cooling schemes are discussed in terms of heat transfer performance and limitations. Large-capacity refrigeration techniques below 2 K are reviewed, with regard to thermodynamic cycles as well as process machinery. Examples drawn from existing or planned projects illustrate the presentation. Keywords: superfluid helium, cryogenics

  5. Laser cooling of solids

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, Richard I [Los Alamos National Laboratory; Sheik-bahae, Mansoor [UNM

    2008-01-01

    We present an overview of solid-state optical refrigeration also known as laser cooling in solids by fluorescence upconversion. The idea of cooling a solid-state optical material by simply shining a laser beam onto it may sound counter intuitive but is rapidly becoming a promising technology for future cryocooler. We chart the evolution of this science in rare-earth doped solids and semiconductors.

  6. Stacking with Stochastic Cooling

    CERN Document Server

    Caspers, Friedhelm

    2004-01-01

    Accumulation of large stacks of antiprotons or ions with the aid of stochastic cooling is more delicate than cooling a constant intensity beam. Basically the difficulty stems from the fact that the optimized gain and the cooling rate are inversely proportional to the number of particles seen by the cooling system. Therefore, to maintain fast stacking, the newly injected batch has to be strongly protected from the Schottky noise of the stack. Vice versa the stack has to be efficiently shielded against the high gain cooling system for the injected beam. In the antiproton accumulators with stacking ratios up to 105, the problem is solved by radial separation of the injection and the stack orbits in a region of large dispersion. An array of several tapered cooling systems with a matched gain profile provides a continuous particle flux towards the high-density stack core. Shielding of the different systems from each other is obtained both through the spatial separation and via the revolution frequencies (filters)....

  7. Alternative Room Cooling System

    Directory of Open Access Journals (Sweden)

    Md. Fazle Rabbi

    2015-06-01

    Full Text Available The rapidly growing population results in an increasing demand for much more residential and commercial buildings, which leads to vertical growth of the buildings and needs proper ventilation of those buildings. Natural air ventilation system is not sufficient for conventional building structures. Hence fans and air-conditioners are must to meet the requirement of proper ventilation as well as space conditioning. Globally building sector consumes largest energy in heating, cooling, ventilation and space conditioning. This load can be minimized by the application of solar chimney and modification in building structure for heating, cooling, ventilation and space conditioning. Passive solar cooling is a subject of interest to provide cooling by using the sun, a powerful energy source. This is done for ensuring human comfort in hot climates. ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers defines Comfort as ‘that state of mind which expresses satisfaction with the thermal environment.’ The present paper describes the development of a solar passive cooling system, which can provide thermal cooling throughout the summer season in hot and humid climates. The constructed passive system works on natural convection mode of air. Such system reduces the inside temperature of up to 5°C from the atmospheric temperature. Temperature can further be reduced by the judicious use of night ventilation.

  8. Noite e dia e alguns monocromos psíquicos Night and day - and some psychical monochromes

    Directory of Open Access Journals (Sweden)

    Edson Luiz André de Sousa

    2006-06-01

    Full Text Available O artigo apresenta uma leitura do conto de Jack London "A sombra e o brilho" mostrando o funcionamento do princípio da mímesis no processo de identificação. Propõe-se a expressão monocromos psíquicos para esses espaços mentais de indiferenciação entre o eu e o Outro. Adota-se a tese de Caillois, que afirma que o eu é permeável ao espaço. Nessa perspectiva, o tema do duplo, amplamente desenvolvido por Freud, é fundamental. Partindo-se de notas sobre o trabalho do fotógrafo cego Bavcar, procura-se mostrar alguns traços da estrutura do olhar. O artigo finaliza mostrando as conexões possíveis dessas reflexões para a prática psicanalítica.The paper presents a reading of Jack London's tale "The Shadow and the brightness", showing how the principle of mimesis works in the process of the identification. We propose to call psychical monochromes the spaces of mental indifference between the self and the other. We follow the thesis of Roger Caillois: "the self is permeable in the space". In this perspective, the subject of the double, developped by Freud is essential. We try to show the dialectic of the structure of the look based in some notes about the work of the blind photographer Bavcar. The article finish with showing the possibles connections of all these points with the clinical work.

  9. Comparing Social Stories™ to Cool versus Not Cool

    Science.gov (United States)

    Leaf, Justin B.; Mitchell, Erin; Townley-Cochran, Donna; McEachin, John; Taubman, Mitchell; Leaf, Ronald

    2016-01-01

    In this study we compared the cool versus not cool procedure to Social Stories™ for teaching various social behaviors to one individual diagnosed with autism spectrum disorder. The researchers randomly assigned three social skills to the cool versus not cool procedure and three social skills to the Social Stories™ procedure. Naturalistic probes…

  10. Measuring the coolness of interactive products: the COOL questionnaire

    DEFF Research Database (Denmark)

    Bruun, Anders; Raptis, Dimitrios; Kjeldskov, Jesper

    2016-01-01

    characteristics. These were used to create an initial pool of question items and 2236 participants were asked to assess 16 mobile devices. By performing exploratory and confirmatory factor analyses, we identified three factors that can measure the perceived inner coolness of interactive products: desirability...... is the COOL questionnaire. We based the creation of the questionnaire on literature suggesting that perceived coolness is decomposed to outer cool (the style of a product) and inner cool (the personality characteristics assigned to it). In this paper, we focused on inner cool, and we identified 11 inner cool...

  11. Lattice design and expected performance of the Muon Ionization Cooling Experiment demonstration of ionization cooling

    Directory of Open Access Journals (Sweden)

    2017-06-01

    Full Text Available Muon beams of low emittance provide the basis for the intense, well-characterized neutrino beams necessary to elucidate the physics of flavor at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using rf cavities. The combined effect of energy loss and reacceleration is to reduce the transverse emittance of the beam (transverse cooling. A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.

  12. Passive Cooling of buildings by night-time ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, Heinrich; Heiselberg, Per

    Due to an overall trend towards an increasing cooling energy demand in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising concept. However, because of uncertainties in thermal comfort predictions, architects and engineers...... are still hesitant to apply passive cooling techniques. As night-time ventilation is highly dependent on climatic conditions, a method for quantifying the climatic cooling potential was developed and the impact of climate warming was investigated. Although a clear decrease was found, significant potential...... will remain, especially if night-time ventilation is applied in combination with other cooling methods. Building energy simulations showed that the performance of night-time ventilation is also affected by the heat transfer at internal room surfaces, as the cooling effect is very limited for heat transfer...

  13. Liquid Cooling/Warming Garment

    Science.gov (United States)

    Koscheyev, Victor S.; Leon, Gloria R.; Dancisak, Michael J.

    2010-01-01

    The NASA liquid cooling/ventilating garment (LCVG) currently in use was developed over 40 years ago. With the commencement of a greater number of extra-vehicular activity (EVA) procedures with the construction of the International Space Station, problems of astronaut comfort, as well as the reduction of the consumption of energy, became more salient. A shortened liquid cooling/warming garment (SLCWG) has been developed based on physiological principles comparing the efficacy of heat transfer of different body zones; the capability of blood to deliver heat; individual muscle and fat body composition as a basis for individual thermal profiles to customize the zonal sections of the garment; and the development of shunts to minimize or redirect the cooling/warming loop for different environmental conditions, physical activity levels, and emergency situations. The SLCWG has been designed and completed, based on extensive testing in rest, exercise, and antiorthostatic conditions. It is more energy efficient than the LCVG currently used by NASA. The total length of tubing in the SLCWG is approximately 35 percent less and the weight decreased by 20 percent compared to the LCVG. The novel features of the innovation are: 1. The efficiency of the SLCWG to maintain thermal status under extreme changes in body surface temperatures while using significantly less tubing than the LCVG. 2. The construction of the garment based on physiological principles of heat transfer. 3. The identification of the body areas that are most efficient in heat transfer. 4. The inclusion of a hood as part of the garment. 5. The lesser consumption of energy.

  14. The definition of cool

    Energy Technology Data Exchange (ETDEWEB)

    Nichiporuk, A.

    2005-05-01

    A new air cooling system at Agnico-Eagle's LaRonde mine, located in the Abitibi Region of Quebec is described. The new system serves a mine operating at 7,250 plus feet level. The system is installed at the surface; it utilizes ammonia to cool water, which cools the air. The system consists of four compressors which lower the temperature of the ammonia to minus 2 degrees C. Water, which at this temperature is 14 degrees, and ammonia pass through a plate heat exchanger simultaneously, however, without coming into contact with each other. The heat transfer that occurs causes the water's temperature to drop to 2 degrees C. The total volume of water cooled is 220 litres per second. The system is capable of reducing 636,000 cfm of air from 30 degrees C to 6 degrees C, to which 214,000 cfm of non-cooled air is added. This mixture, which is maintained at approximately 8 degrees C throughout the summer season, is sent underground to the deepest parts of the mine. The system runs from June to September, depending on the weather. In the evenings, when the temperature dips to around four to five degrees C, the water is shut down and side doors are opened to prevent the water from freezing.

  15. Laser cooling of a diatomic molecule

    CERN Document Server

    Shuman, E S; DeMille, D

    2011-01-01

    It has been roughly three decades since laser cooling techniques produced ultracold atoms, leading to rapid advances in a vast array of fields. Unfortunately laser cooling has not yet been extended to molecules because of their complex internal structure. However, this complexity makes molecules potentially useful for many applications. For example, heteronuclear molecules possess permanent electric dipole moments which lead to long-range, tunable, anisotropic dipole-dipole interactions. The combination of the dipole-dipole interaction and the precise control over molecular degrees of freedom possible at ultracold temperatures make ultracold molecules attractive candidates for use in quantum simulation of condensed matter systems and quantum computation. Also ultracold molecules may provide unique opportunities for studying chemical dynamics and for tests of fundamental symmetries. Here we experimentally demonstrate laser cooling of the molecule strontium monofluoride (SrF). Using an optical cycling scheme re...

  16. Analysis of Turbine Blade Relative Cooling Flow Factor Used in the Subroutine Coolit Based on Film Cooling Correlations

    Science.gov (United States)

    Schneider, Steven J.

    2015-01-01

    Heat transfer correlations of data on flat plates are used to explore the parameters in the Coolit program used for calculating the quantity of cooling air for controlling turbine blade temperature. Correlations for both convection and film cooling are explored for their relevance to predicting blade temperature as a function of a total cooling flow which is split between external film and internal convection flows. Similar trends to those in Coolit are predicted as a function of the percent of the total cooling flow that is in the film. The exceptions are that no film or 100 percent convection is predicted to not be able to control blade temperature, while leaving less than 25 percent of the cooling flow in the convection path results in nearing a limit on convection cooling as predicted by a thermal effectiveness parameter not presently used in Coolit.

  17. Study on the utilization of the energy produced by the exhaust gases and the cooling water of a internal combustion engine; Estudo do aproveitamento da energia obtida pelos gases de escapamento e pela agua de resfriamento de um motor de combustao interna

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Andre Luiz dos; Arroyo, Narciso Angel Ramos [Santa Catarina Univ., Florianopolis (Brazil). Dept. de Engenharia Mecanica. Lab. de Combustao e Motores Termicos]. E-mail: als2000@tutopia.com.br; arroyo@sinmec.ufsc.br

    2000-07-01

    This work is about heat balance of an automotive internal combustion engine of 4 cylinders, using ethylic alcohol, and utilize the energy obtained in the exhaust gas and the water cooling system. This paper show an theoretical - experimental model for use this energy in an absorption refrigeration system using the work fluid water and Li Br. In this paper are analyzed engines charges of 30%, 50% and 100%. The results shows that for this charges and for any speed of the engines, the energy obtained in the evaporator are significant. (author)

  18. Aspects of Household Cooling Technology

    OpenAIRE

    Mrzyglod, Matthias; Holzer, Stefan

    2014-01-01

    Actually available household cooling appliances in the highest efficiency class may consume less then 10W average electrical power. To achieve such power consumptions special challenges for the cooling system had to overcome. The related cooling system design has to consider several effects, which arise from the corresponding low cooling capacity demand, start/stop cycles and additional power consumptions by control accessories. The lecture provides symptomatic aspects of cooling technology, ...

  19. Heating and Cooling Protostellar Disks

    CERN Document Server

    Hirose, S

    2011-01-01

    We examine heating and cooling in protostellar disks using 3-D radiation-MHD calculations of a patch of the Solar nebula at 1 AU, employing the shearing-box and flux-limited radiation diffusion approximations. The disk atmosphere is ionized by stellar X-rays, well-coupled to magnetic fields, and sustains a turbulent accretion flow driven by magneto-rotational instability, while the interior is resistive and magnetically dead. The turbulent layers heat by absorbing the light from the central star and by dissipating the magnetic fields. They are optically-thin to their own radiation and cool inefficiently. The optically-thick interior in contrast is heated only weakly, by re-emission from the atmosphere. The interior is colder than a classical viscous model, and isothermal. The magnetic fields support an extended atmosphere that absorbs the starlight 1.5 times higher than the hydrostatic viscous model. The disk thickness thus measures not the internal temperature, but the magnetic field strength. Fluctuations i...

  20. Heat pipe turbine vane cooling

    Energy Technology Data Exchange (ETDEWEB)

    Langston, L.; Faghri, A. [Univ. of Connecticut, Storrs, CT (United States)

    1995-10-01

    The applicability of using heat pipe principles to cool gas turbine vanes is addressed in this beginning program. This innovative concept involves fitting out the vane interior as a heat pipe and extending the vane into an adjacent heat sink, thus transferring the vane incident heat transfer through the heat pipe to heat sink. This design provides an extremely high heat transfer rate and an uniform temperature along the vane due to the internal change of phase of the heat pipe working fluid. Furthermore, this technology can also eliminate hot spots at the vane leading and trailing edges and increase the vane life by preventing thermal fatigue cracking. There is also the possibility of requiring no bleed air from the compressor, and therefore eliminating engine performance losses resulting from the diversion of compressor discharge air. Significant improvement in gas turbine performance can be achieved by using heat pipe technology in place of conventional air cooled vanes. A detailed numerical analysis of a heat pipe vane will be made and an experimental model will be designed in the first year of this new program.

  1. Doppler cooling a microsphere

    CERN Document Server

    Barker, P F

    2010-01-01

    Doppler cooling the center-of-mass motion of an optically levitated microsphere via the velocity dependent scattering force from narrow whispering gallery mode (WGM) resonances is described. Light that is red detuned from the WGM resonance can be used to damp the center-of-mass motion in a process analogous to the Doppler cooling of atoms. Leakage of photons out of the microsphere when the incident field is near resonant with the narrow WGM resonance acts to damp the motion of the sphere. The scattering force is not limited by saturation, but can be controlled by the incident power. Cooling times on the order of seconds are calculated for a 20 micron diameter silica microsphere trapped within optical tweezers, with a Doppler temperature limit in the microKelvin regime.

  2. Natural radiative cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.

    1979-01-01

    Natural radiative cooling at night was measured based on the surface-radiation spectrum after the heat balance of the surface exposed to the sun had been reradiated. A concept equivalent to the sky temperature and a concept useful for obtaining the net heat flux are discussed. The highest possible equilibrium temperature of the selective surface can be lowered; however, how to apply this practically is not yet known. A simple radiator, completely enclosed by a transparent screen, can produce a significant and inexpensive cooling effect. The results of experiments carried out in an area such as Padua, Italy, where the climate is not suitable for cooling purposes can still be predicted theoretically. The possibility of using the collector for heat collection during the day and as a radiator at night is indicated.

  3. Clean cooling; Saubere Kuehlung

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-07-01

    The round hybrid cooling towers which Balcke-Duerr GmbH is currently building for the 550-MW-IGCC-power-station of a refinery project on Sardinia have to meet particularly stringent requirements as seawater is used for cooling. The advantages are: Avoidance of visible plume with minimal energy consumption, optimal plume exit velocity and discharge, greatest possible stability of the plume column, avoidance of interference and recirculation, high operating reliability of the cooling tower. (orig.) [Deutsch] Derzeit werden die Kuehltuerme fuer ein 550-MW-IGCC-Kraftwerk einer Raffinierie auf Sardinien errichtet. Die Anforderungen an die Technik sind hoch, denn gekuehlt wird mit Seewasser. Zum Einsatz kommen Hybridrundkuehltuerme der Balcke-Duerr GmbH, Ratingen. Damit setzt das Unternehmen diesen Typ erstmals ausserhalb von Deutschland ein. (orig.)

  4. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  5. Research on Cooling Effectiveness in Stepped Slot Film Cooling Vane

    Institute of Scientific and Technical Information of China (English)

    LI Yulong; WU Hong; ZHOU Feng; RONG Chengjun

    2016-01-01

    As one of the most important developments in air cooling technology for hot parts of the aero-engine,film cooling technology has been widely used.Film cooling hole structure exists mainly in areas that have high temperature,uneven cooling effectiveness issues when in actual use.The first stage turbine vanes of the aero-engine consume the largest portion of cooling air,thereby the research on reducing the amount of cooling air has the greatest potential.A new stepped slot film cooling vane with a high cooling effectiveness and a high cooling uniformity was researched initially.Through numerical methods,the affecting factors of the cooling effectiveness of a vane with the stepped slot film cooling structure were researched.This paper focuses on the cooling effectiveness and the pressure loss in different blowing ratio conditions,then the most reasonable and scientific structure parameter can be obtained by analyzing the results.The results show that 1.0 mm is the optimum slot width and 10.0 is the most reasonable blowing ratio.Under this condition,the vane achieved the best cooling result and the highest cooling effectiveness,and also retained a low pressure loss.

  6. A belief-propagation-based decoding method for two-dimensional barcodes with monochrome auxiliary lines robust against non-uniform geometric distortion

    Science.gov (United States)

    Kamizuru, Kohei; Nakamura, Kazuya; Kawasaki, Hiroshi; Ono, Satoshi

    2017-03-01

    Two-dimensional (2D) codes are widely used for various fields such as production, logistics, and marketing thanks to their larger capacity than one-dimensional barcodes. However, they are subject to distortion when printed on non-rigid materials, such as papers and clothes. Although general 2D code decoders correct uniform distortion such as perspective distortion, it is difficult to correct non-uniform and irregular distortion of the 2D code itself. This paper proposes a decoding method for the 2D code, which models monochrome auxiliary line recognition as Markov random field, and solves it using belief propagation.

  7. Anomalous law of cooling.

    Science.gov (United States)

    Lapas, Luciano C; Ferreira, Rogelma M S; Rubí, J Miguel; Oliveira, Fernando A

    2015-03-14

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergoes a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature may oscillate. Despite this anomalous behavior, we show that the variation of entropy remains always positive in accordance with the second law of thermodynamics.

  8. Anomalous law of cooling

    Science.gov (United States)

    Lapas, Luciano C.; Ferreira, Rogelma M. S.; Rubí, J. Miguel; Oliveira, Fernando A.

    2015-03-01

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergoes a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature may oscillate. Despite this anomalous behavior, we show that the variation of entropy remains always positive in accordance with the second law of thermodynamics.

  9. Superconductor rotor cooling system

    Science.gov (United States)

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  10. A Cool Emperor Penguin

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    哇,这只帝企鹅的胸前居然有个心形!It’s cool!(乐天:没错,它的胸前少了这幺撮毛,应该会感觉挺凉快的)cool在这里可不是“凉快”的意思,而是“酷.帅气”的意思。我们《英语大王》的英文名字就叫English Cool Kids哦!(乐天拿出一副墨镜戴上:

  11. Rapid cooled lens cell

    Science.gov (United States)

    Stubbs, David M.; Hsu, Ike C.

    1991-12-01

    This paper describes the optomechanical design, thermal analysis, fabrication, and test evaluation processes followed in developing a rapid cooled, infrared lens cell. Thermal analysis was the key engineering discipline exercised in the design phase. The effect of thermal stress on the lens, induced by rapid cooling of the lens cell, was investigated. Features of this lens cell that minimized the thermal stress will be discussed in a dedicated section. The results of thermal analysis on the selected lens cell design and the selection of the flow channel design in the heat exchanger will be discussed. Throughout the paper engineering drawings, illustrations, analytical results, and photographs of actual hardware are presented.

  12. Gas cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1972-06-01

    Although most of the development work on fast breeder reactors has been devoted to the use of liquid metal cooling, interest has been expressed for a number of years in alternative breeder concepts using other coolants. One of a number of concepts in which interest has been retained is the Gas-Cooled Fast Reactor (GCFR). As presently envisioned, it would operate on the uranium-plutonium mixed oxide fuel cycle, similar to that used in the Liquid Metal Fast Breeder Reactor (LMFBR), and would use helium gas as the coolant.

  13. Quantum thermodynamic cooling cycle

    CERN Document Server

    Palao, J P; Gordon, J M; Palao, Jose P.; Kosloff, Ronnie; Gordon, Jeffrey M.

    2001-01-01

    The quantum-mechanical and thermodynamic properties of a 3-level molecular cooling cycle are derived. An inadequacy of earlier models is rectified in accounting for the spontaneous emission and absorption associated with the coupling to the coherent driving field via an environmental reservoir. This additional coupling need not be dissipative, and can provide a thermal driving force - the quantum analog of classical absorption chillers. The dependence of the maximum attainable cooling rate on temperature, at ultra-low temperatures, is determined and shown to respect the recently-established fundamental bound based on the second and third laws of thermodynamics.

  14. Cooling of neutron stars with diffusive envelopes

    CERN Document Server

    Beznogov, M V; Haensel, P; Yakovlev, D G; Zdunik, J L

    2016-01-01

    We study the effects of heat blanketing envelopes of neutron stars on their cooling. To this aim, we perform cooling simulations using newly constructed models of the envelopes composed of binary ion mixtures (H--He, He--C, C--Fe) varying the mass of lighter ions (H, He or C) in the envelope. The results are compared with those calculated using the standard models of the envelopes which contain the layers of lighter (accreted) elements (H, He and C) on top of the Fe layer, varying the mass of accreted elements. The main effect is that the chemical composition of the envelopes influences their thermal conductivity and, hence, thermal insulation of the star. For illustration, we apply these results to estimate the internal temperature of the Vela pulsar and to study the cooling of neutron stars of ages of 0.1 - 1 Myr at the photon cooling stage. The uncertainties of the cooling models associated with our poor knowledge of chemical composition of the heat insulating envelopes strongly complicate theoretical reco...

  15. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), David, CA (United States)

    2012-04-01

    The purpose of this measure guideline is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  16. Elementary stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Tollestrup, A.V.; Dugan, G

    1983-12-01

    Major headings in this review include: proton sources; antiproton production; antiproton sources and Liouville, the role of the Debuncher; transverse stochastic cooling, time domain; the accumulator; frequency domain; pickups and kickers; Fokker-Planck equation; calculation of constants in the Fokker-Planck equation; and beam feedback. (GHT)

  17. ELECTRON COOLING FOR RHIC.

    Energy Technology Data Exchange (ETDEWEB)

    BEN-ZVI,I.

    2001-05-13

    The Accelerator Collider Department (CAD) at Brookhaven National Laboratory is operating the Relativistic Heavy Ion Collider (RHIC), which includes the dual-ring, 3.834 km circumference superconducting collider and the venerable AGS as the last part of the RHIC injection chain. CAD is planning on a luminosity upgrade of the machine under the designation RHIC II. One important component of the RHIC II upgrade is electron cooling of RHIC gold ion beams. For this purpose, BNL and the Budker Institute of Nuclear Physics in Novosibirsk entered into a collaboration aimed initially at the development of the electron cooling conceptual design, resolution of technical issues, and finally extend the collaboration towards the construction and commissioning of the cooler. Many of the results presented in this paper are derived from the Electron Cooling for RHIC Design Report [1], produced by the, BINP team within the framework of this collaboration. BNL is also collaborating with Fermi National Laboratory, Thomas Jefferson National Accelerator Facility and the University of Indiana on various aspects of electron cooling.

  18. Thermo-fluid simulation of a rotating disc with radial cooling passages / Francois Holtzhausen

    OpenAIRE

    Holtzhausen, Francois

    2003-01-01

    Turbine blade cooling via internal cooling channels is a very important aspect in modern-day gas turbine cycles. The need for blade cooling stems from the fact that higher cycle efficiencies requires higher maximum temperatures and therefore also higher turbine inlet temperatures. In order to evaluate the effects of these cooling flows on the cycle as a whole under various load conditions, it is necessary to simulate the compressible flow with heat transfer within the channe...

  19. Numerical simulation on internal and external flow field of a SCAL indirect air cooling tower%SCAL型间接空冷塔内外流场数值模拟

    Institute of Scientific and Technical Information of China (English)

    田松峰; 柴艳琴; 向同琼; 周广沙

    2014-01-01

    根据某SCAL型自然通风空气冷却塔(空冷塔)散热管束的实际尺寸和冷却三角的布置方式,对塔底换热单元建立了几何模型,并基于 RNG k-ε紊流模型和多孔介质模型,对塔内外流场进行了三维数值模拟,探究了环境条件对其运行特性的影响。研究结果表明:随着环境风速的增加,空冷塔迎风面进口风速逐渐增加,而侧风面和背风面的进口风速则呈下降趋势,且该趋势随温度的上升愈加明显;空冷塔的通风量和塔出口速度随环境风速的增加先增大后减小,且在风速为2m/s 时,其通风量和出口速度最大。%According to the actual size of cooling tube bundle and the arrangement of cooling trian-gle of a surface condenser aluminum exchangers (SCAL)natural draft cooling tower,the geomet-ric model of heat transfer elements at the tower bottom was established.On the basis of the RNG k-εturbulence model and porous medium model,three-dimensional numerical simulation was car-ried out for the inner and external flow field of the air cooling tower,to investigate the influence of environmental conditions on the tower's operation performance.The results show that,with an increase in ambient wind speed,the inlet air speed at windward side of the tower increases gradu-ally,while that at crosswind side and lee side decreases and tends to be obvious;the tower ventila-tion rate and outlet air speed increases at first and then decreases,and their maximum values ap-pear when the wind speed is 2 m/s.

  20. Synchrotron X-ray adaptative monochromator: study and realization of a prototype; Monochromateur adaptatif pour rayonnement X synchrotron: etude et realisation d`un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Dezoret, D.

    1995-12-12

    This work presents a study of a prototype of a synchrotron X-ray monochromator. The spectral qualities of this optic are sensitive to the heat loads which are particularly important on third synchrotron generation like ESRF. Indeed, powers generated by synchrotron beams can reach few kilowatts and power densities about a few tens watts per square millimeters. The mechanical deformations of the optical elements of the beamlines issue issue of the heat load can damage their spectral efficiencies. In order to compensate the deformations, wa have been studying the transposition of the adaptive astronomical optics technology to the x-ray field. First, we have considered the modifications of the spectral characteristics of a crystal induced by x-rays. We have established the specifications required to a technological realisation. Then, thermomechanical and technological studies have been required to transpose the astronomical technology to an x-ray technology. After these studies, we have begun the realisation of a prototype. This monochromator is composed by a crystal of silicon (111) bonded on a piezo-electric structure. The mechanical control is a loop system composed by a infrared light, a Shack-Hartmann CDD and wave front analyser. This system has to compensate the deformations of the crystal in the 5 kcV to 60 kcV energy range with a power density of 1 watt per square millimeters. (authors).

  1. A spherical grating monochromator and beamline optimised for the provision of polarised synchrotron radiation in the photon energy range 20-200 eV

    Energy Technology Data Exchange (ETDEWEB)

    Finetti, P.; Holland, D.M.P. E-mail: d.m.p.holland@dl.ac.uk; Latimer, C.J.; Binns, C.; Quinn, F.M.; Bowler, M.A.; Grant, A.F.; Mythen, C.S

    2001-12-01

    The design and performance of a spherical grating monochromator and beamline optimised for experiments requiring polarised radiation are described. The beamline is mounted on a bending magnet source at the Synchrotron Radiation Source at Daresbury Laboratory, and the monochromator incorporates three gratings to cover the photon energy range 20-200 eV. The relative first- and higher-order grating efficiencies have been measured by means of photoelectron spectroscopy and have been compared to theoretical predictions. A movable aperture, placed in the optical path between the source and the first mirror, defines the photon emission directions of the beam entering the beamline. The polarisation of the radiation leaving the beamline is determined both by the vertical position of this aperture and by the modifications introduced by the beamline geometry and the optical components. The modification to the polarisation is difficult to calculate analytically, and a satisfactory quantitative assessment can only be accomplished through a combination of reflectivity and ray-tracing analysis. A reflection polarimeter has been used to obtain a full characterisation of the polarisation in the energy range 20-40 eV. These measurements have enabled the Stokes parameters to be deduced. The degree of linear polarisation has also been investigated through angle resolved photoelectron spectroscopy measurements.

  2. Calculations and surface quality measurements of high-asymmetry angle x-ray crystal monochromators for advanced x-ray imaging and metrological applications

    Science.gov (United States)

    Zápražný, Zdenko; Korytár, Dušan; Jergel, Matej; Šiffalovič, Peter; Dobročka, Edmund; Vagovič, Patrik; Ferrari, Claudio; Mikulík, Petr; Demydenko, Maksym; Mikloška, Marek

    2015-03-01

    We present the numerical optimization and the technological development progress of x-ray optics based on asymmetric germanium crystals. We show the results of several basic calculations of diffraction properties of germanium x-ray crystal monochromators and of an analyzer-based imaging method for various asymmetry factors using an x-ray energy range from 8 to 20 keV. The important parameter of highly asymmetric monochromators as image magnifiers or compressors is the crystal surface quality. We have applied several crystal surface finishing methods, including advanced nanomachining using single-point diamond turning (SPDT), conventional mechanical lapping, chemical polishing, and chemomechanical polishing, and we have evaluated these methods by means of atomic force microscopy, diffractometry, reciprocal space mapping, and others. Our goal is to exclude the chemical etching methods as the final processing technique because it causes surface undulations. The aim is to implement very precise deterministic methods with a control of surface roughness down to 0.1 nm. The smallest roughness (˜0.3 nm), best planarity, and absence of the subsurface damage were observed for the sample which was machined using an SPDT with a feed rate of 1 mm/min and was consequently polished using a fine polishing 15-min process with a solution containing SiO2 nanoparticles (20 nm).

  3. A point-focusing small angle x-ray scattering camera using a doubly curved monochromator of a W/Si multilayer

    Science.gov (United States)

    Sasanuma, Yuji; Law, Robert V.; Kobayashi, Yuji

    1996-03-01

    A point-focusing small angle x-ray scattering (SAXS) camera using a doubly curved monochromator of a W/Si multilayer has been designed, constructed, and tested. The two radii of curvature of the monochromator are 20 400 and 7.6 mm. The reflectivity of its first-order Bragg reflection for CuKα radiation was calculated to be 0.82, being comparable to that (0.81) of its total reflection. By only 10 s x-ray exposure, scattering from a high-density polyethylene film was detected on an imaging plate (IP). A rotating-anode x-ray generator operated at 40 kV and 30 mA was used. Diffraction from rat-tail collagen has shown that the optical arrangement gives the Bragg spacing up to, at least, 30 nm for CuKα radiation. Combined with IPs, the camera may permit us to carry out time-resolved SAXS measurements for phase behaviors of liquid crystals, lipids, polymer alloys, etc., on conventional x-ray generators available in laboratories.

  4. Sorption cooling: a valid extension to passive cooling

    NARCIS (Netherlands)

    Doornink, D.J.; Burger, J.F.; Brake, ter H.J.M.

    2008-01-01

    Passive cooling has shown to be a very dependable cryogenic cooling method for space missions. Several missions employ passive radiators to cool down their delicate sensor systems for many years, without consuming power, without exporting vibrations or producing electromagnetic interference. So for

  5. Comments on Ionization Cooling Channel Characteristics

    CERN Document Server

    Neuffer, David

    2013-01-01

    Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the ionization cooling theory developed previously. In this paper we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.

  6. Comments on Ionization Cooling Channel Characteristics

    OpenAIRE

    Neuffer, David

    2013-01-01

    Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the ionization cooling theory developed previously. In this paper we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.

  7. STOCHASTIC COOLING FOR BUNCHED BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    BLASKIEWICZ, M.

    2005-05-16

    Problems associated with bunched beam stochastic cooling are reviewed. A longitudinal stochastic cooling system for RHIC is under construction and has been partially commissioned. The state of the system and future plans are discussed.

  8. ALP hints from cooling anomalies

    CERN Document Server

    Giannotti, Maurizio

    2015-01-01

    We review the current status of the anomalies in stellar cooling and argue that, among the new physics candidates, an axion-like particle would represent the best option to account for the hinted additional cooling.

  9. Cooling devices in laser therapy

    Directory of Open Access Journals (Sweden)

    Anupam Das

    2016-01-01

    Full Text Available Cooling devices and methods are now integrated into most laser systems, with a view to protecting the epidermis, reducing pain and erythema and improving the efficacy of laser. On the basis of method employed, it can be divided into contact cooling and non-contact cooling. With respect to timing of irradiation of laser, the nomenclatures include pre-cooling, parallel cooling and post-cooling. The choice of the cooling device is dictated by the laser device, the physician′s personal choice with respect to user-friendliness, comfort of the patient, the price and maintenance costs of the device. We hereby briefly review the various techniques of cooling, employed in laser practice.

  10. Laser cooling of a diatomic molecule.

    Science.gov (United States)

    Shuman, E S; Barry, J F; Demille, D

    2010-10-14

    It has been roughly three decades since laser cooling techniques produced ultracold atoms, leading to rapid advances in a wide array of fields. Laser cooling has not yet been extended to molecules because of their complex internal structure. However, this complexity makes molecules potentially useful for a wide range of applications. For example, heteronuclear molecules possess permanent electric dipole moments that lead to long-range, tunable, anisotropic dipole-dipole interactions. The combination of the dipole-dipole interaction and the precise control over molecular degrees of freedom possible at ultracold temperatures makes ultracold molecules attractive candidates for use in quantum simulations of condensed-matter systems and in quantum computation. Also, ultracold molecules could provide unique opportunities for studying chemical dynamics and for tests of fundamental symmetries. Here we experimentally demonstrate laser cooling of the polar molecule strontium monofluoride (SrF). Using an optical cycling scheme requiring only three lasers, we have observed both Sisyphus and Doppler cooling forces that reduce the transverse temperature of a SrF molecular beam substantially, to a few millikelvin or less. At present, the only technique for producing ultracold molecules is to bind together ultracold alkali atoms through Feshbach resonance or photoassociation. However, proposed applications for ultracold molecules require a variety of molecular energy-level structures (for example unpaired electronic spin, Omega doublets and so on). Our method provides an alternative route to ultracold molecules. In particular, it bridges the gap between ultracold (submillikelvin) temperatures and the ∼1-K temperatures attainable with directly cooled molecules (for example with cryogenic buffer-gas cooling or decelerated supersonic beams). Ultimately, our technique should allow the production of large samples of molecules at ultracold temperatures for species that are chemically

  11. New Technology in Hydrogen Absorbers for Muon Cooling Channels

    CERN Document Server

    Cummings, M A C

    2005-01-01

    Ionization cooling is the only technique fast enough to cool and focus muons for neutrino factories and muon colliders, and hydrogen is the optimal material for maximum cooling and minimal multiple scattering. Liquid hydrogen absorber R&D for the Muon Collaboration has proceeded on parallel and complementary fronts. The continuing LH2 absorber engineering and technical developments by the MuCool group conducted by ICAR* institutions (NIU, IIT and UIUC), the University of Mississippi and Oxford University, in cooperation with Fermilab, will be summarized, including results from the first hydrogen absorber tests at the newly constructed FNAL Mucool Test Area (MTA). The program includes designs for the high-powered test of an absorber prototype (external heat exchange) at the MTA which are nearing completion to be installed by summer 2005, an alternative absorber design (internal heat exchange) being finalized for the approved cooling experiment (MICE) at Rutherford-Appleton Laboratory, and a novel idea for ...

  12. Rotational Laser Cooling of Vibrationally and Translationally Cold Molecular Ions

    DEFF Research Database (Denmark)

    Drewsen, Michael

    2011-01-01

    by sympathetic cooling with Doppler laser cooled Mg+ ions. Giving the time for the molecules to equilibrate internally to the room temperature blackbody radiation, the vibrational degree of freedom will freeze out, leaving only the rotational degree of freedom to be cooled. We report here on the implementation...... of a new technique for laser-induced rotational ground-state cooling of vibrationally and translationally cold MgH+ ions [10]. The scheme is based on excitation of a single rovibrational transition [11], and it should be generalizable to any diatomic polar molecular ion, given appropriate mid......-infrared laser sources such as a quantum cascade laser are available. In recent experiments, a nearly 15-fold increase in the rotational ground-state population was obtained, with the resulting ground-state population of 36,7±1,2 %, equivalent to that of a thermal distribution at about 20 K. The obtained cooling...

  13. Self pumping magnetic cooling

    Science.gov (United States)

    Chaudhary, V.; Wang, Z.; Ray, A.; Sridhar, I.; Ramanujan, R. V.

    2017-01-01

    Efficient thermal management and heat recovery devices are of high technological significance for innovative energy conservation solutions. We describe a study of a self-pumping magnetic cooling device, which does not require external energy input, employing Mn-Zn ferrite nanoparticles suspended in water. The device performance depends strongly on magnetic field strength, nanoparticle content in the fluid and heat load temperature. Cooling (ΔT) by ~20 °C and ~28 °C was achieved by the application of 0.3 T magnetic field when the initial temperature of the heat load was 64 °C and 87 °C, respectively. These experiments results were in good agreement with simulations performed with COMSOL Multiphysics. Our system is a self-regulating device; as the heat load increases, the magnetization of the ferrofluid decreases; leading to an increase in the fluid velocity and consequently, faster heat transfer from the heat source to the heat sink.

  14. Cooled particle accelerator target

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2005-06-14

    A novel particle beam target comprising: a rotating target disc mounted on a retainer and thermally coupled to a first array of spaced-apart parallel plate fins that extend radially inwardly from the retainer and mesh without physical contact with a second array of spaced-apart parallel plate fins that extend radially outwardly from and are thermally coupled to a cooling mechanism capable of removing heat from said second array of spaced-apart fins and located within the first array of spaced-apart parallel fins. Radiant thermal exchange between the two arrays of parallel plate fins provides removal of heat from the rotating disc. A method of cooling the rotating target is also described.

  15. Water Cooled Mirror Design

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pulliam, Elias Noel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-30

    This design is intended to replace the current mirror setup being used for the NorthStar Moly 99 project in order to monitor the target coupon. The existing setup has limited movement for camera alignment and is difficult to align properly. This proposed conceptual design for a water cooled mirror will allow for greater thermal transfer between the mirror and the water block. It will also improve positioning of the mirror by using flexible vacuum hosing and a ball head joint capable of a wide range of motion. Incorporating this design into the target monitoring system will provide more efficient cooling of the mirror which will improve the amount of diffraction caused by the heating of the mirror. The process of aligning the mirror for accurate position will be greatly improved by increasing the range of motion by offering six degrees of freedom.

  16. Magnetic entropy and cooling

    DEFF Research Database (Denmark)

    Hansen, Britt Rosendahl; Kuhn, Luise Theil; Bahl, Christian Robert Haffenden

    2010-01-01

    Some manifestations of magnetism are well-known and utilized on an everyday basis, e.g. using a refrigerator magnet for hanging that important note on the refrigerator door. Others are, so far, more exotic, such as cooling by making use of the magnetocaloric eect. This eect can cause a change...... or nitrogen liquefaction or for room-temperature cooling. The magnetocaloric eect can further be used to determine phase transition boundaries, if a change in the magnetic state occurs at the boundary.In this talk, I will introduce the magnetocaloric eect (MCE) and the two equations, which characterize...... in the temperature of a magnetic material when a magnetic eld is applied or removed. For many years, experimentalists have made use of dilute paramagnetic materials to achieve milliKelvin temperatures by use of the magnetocaloric eect. Also, research is done on materials, which might be used for hydrogen, helium...

  17. Cooling Floor AC Systems

    Science.gov (United States)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  18. Heating, ventilation and cooling

    CSIR Research Space (South Africa)

    Osburn, L

    2009-02-01

    Full Text Available content and is evaporated by the air stream with less moisture. Enthalpy wheels are more effective at transferring energy between the air streams as both sensible and latent heat is transferred. Ground-Coupled Heat Exchanger Ground-coupled heat... with high diurnal temperature variations. Evaporative Coolers Evaporative coolers work on the concept that the evaporation of water has a cooling effect on its immediate environment due to the latent heat that it absorbs in order to evaporate...

  19. Cooled Ion Frequency Standard.

    Science.gov (United States)

    2014-09-26

    when the cooling laser is turned off, the ions are heated by: (1) background gas collisions and (2) a plasma heating process which may be " resonant ...causes heating in our Penning traps. One way resonant particle transport is mediated is by misalignm.nt between the trap’s magnetic and electric axis...using computer solutions. The trap of Fig. 1 is noteworthy because although the inner surfaces of the trap are machined with simple conical cuts, the

  20. 隔爆型水冷变频器内部结露机理及其试验研究%Internal Condensation Mechanism of Explosion-proof Water-cooling Frequency Converter and Its Experimental Research

    Institute of Scientific and Technical Information of China (English)

    高贵军; 寇子明; 张俊; 吴怀亮

    2012-01-01

    Damp atmosphere in explosion-proof enclosure of explosion-proof water-cooling frequency converter could lead to condensation during hot and cold variation, worse still, the condensed water may cause short circuit and destroy the converter. The condensation mechanism was qualitatively analyzed, and the relationship model was established about air temperature, air humidity and dew-point temperature, which was applied to determine whether there was condensation in the cavity. The correctness of the relationship model was verified by simulation test. The influence of flow and temperature of cooling water on condensation was analyzed, and a conclusion was gotten that the bigger difference between atmosphere temperature and dew-point temperature, the more serious condensation. It was pointed out that condensation in the explosion-proof enclosure can be controlled by means of cooling or heating.%针对隔爆型水冷变频器隔爆腔体内部的高湿度空气在冷热变化过程中会出现结露现象甚至产生冷凝水而导致电路短路的问题,对隔爆腔体内部结露机理进行了定性分析,提出了箱体内空气温度、空气湿度与露点温度的关系模型,并以此作为判断箱体内是否结露的依据;利用模拟试验方法验证了该关系模型的正确性,并分析了隔爆型水冷变频器的冷却水流量与温度对结露的影响情况,得出空气温度与露点温度的差值越大则结露越严重的结论,指出通过冷却或加热手段即可有效避免隔爆腔体内部出现结露现象.

  1. Cooling of Electric Motors Used for Propulsion on SCEPTOR

    Science.gov (United States)

    Christie, Robert J.; Dubois, Arthur; Derlaga, Joseph M.

    2017-01-01

    NASA is developing a suite of hybrid-electric propulsion technologies for aircraft. These technologies have the benefit of lower emissions, diminished noise, increased efficiency, and reduced fuel burn. These will provide lower operating costs for aircraft operators. Replacing internal combustion engines with distributed electric propulsion is a keystone of this technology suite, but presents many new problems to aircraft system designers. One of the problems is how to cool these electric motors without adding significant aerodynamic drag, cooling system weight or fan power. This paper discusses the options evaluated for cooling the motors on SCEPTOR (Scalable Convergent Electric Propulsion Technology and Operations Research): a project that will demonstrate Distributed Electric Propulsion technology in flight. Options for external and internal cooling, inlet and exhaust locations, ducting and adjustable cowling, and axial and centrifugal fans were evaluated. The final design was based on a trade between effectiveness, simplicity, robustness, mass and performance over a range of ground and flight operation environments.

  2. Electron Cooling of RHIC

    CERN Document Server

    Ben-Zvi, Ilan; Barton, Donald; Beavis, Dana; Blaskiewicz, Michael; Bluem, Hans; Brennan, Joseph M; Bruhwiler, David L; Burger, Al; Burov, Alexey; Burrill, Andrew; Calaga, Rama; Cameron, Peter; Chang, Xiangyun; Cole, Michael; Connolly, Roger; Delayen, Jean R; Derbenev, Yaroslav S; Eidelman, Yury I; Favale, Anthony; Fedotov, Alexei V; Fischer, Wolfram; Funk, L W; Gassner, David M; Hahn, Harald; Harrison, Michael; Hershcovitch, Ady; Holmes, Douglas; Hseuh Hsiao Chaun; Johnson, Peter; Kayran, Dmitry; Kewisch, Jorg; Kneisel, Peter; Koop, Ivan; Lambiase, Robert; Litvinenko, Vladimir N; MacKay, William W; Mahler, George; Malitsky, Nikolay; McIntyre, Gary; Meng, Wuzheng; Merminga, Lia; Meshkov, Igor; Mirabella, Kerry; Montag, Christoph; Nagaitsev, Sergei; Nehring, Thomas; Nicoletti, Tony; Oerter, Brian; Parkhomchuk, Vasily; Parzen, George; Pate, David; Phillips, Larry; Preble, Joseph P; Rank, Jim; Rao, Triveni; Rathke, John; Roser, Thomas; Russo, Thomas; Scaduto, Joseph; Schultheiss, Tom; Sekutowicz, Jacek; Shatunov, Yuri; Sidorin, Anatoly O; Skrinsky, Aleksander Nikolayevich; Smirnov, Alexander V; Smith, Kevin T; Todd, Alan M M; Trbojevic, Dejan; Troubnikov, Grigory; Wang, Gang; Wei, Jie; Williams, Neville; Wu, Kuo-Chen; Yakimenko, Vitaly; Zaltsman, Alex; Zhao, Yongxiang; ain, Animesh K

    2005-01-01

    We report progress on the R&D program for electron-cooling of the Relativistic Heavy Ion Collider (RHIC). This electron cooler is designed to cool 100 GeV/nucleon at storage energy using 54 MeV electrons. The electron source will be a superconducting RF photocathode gun. The accelerator will be a superconducting energy recovery linac. The frequency of the accelerator is set at 703.75 MHz. The maximum electron bunch frequency is 9.38 MHz, with bunch charge of 20 nC. The R&D program has the following components: The photoinjector and its photocathode, the superconducting linac cavity, start-to-end beam dynamics with magnetized electrons, electron cooling calculations including benchmarking experiments and development of a large superconducting solenoid. The photoinjector and linac cavity are being incorporated into an energy recovery linac aimed at demonstrating ampere class current at about 20 MeV. A Zeroth Order Design Report is in an advanced draft state, and can be found on the web at http://www.ags...

  3. Low mass integrated cooling

    CERN Document Server

    Mapelli, Alessandro

    2014-01-01

    Low mass on - detec tor cooling systems are being developed and stud ied by the Detector Technology group (PH - DT) in the CERN Physics Department in close collaboration with LHC and non - LHC experiments . Two approaches are currently being investigated. The first approach, for barrel configurations, consists in integrating the cooli ng apparatus in light mechanical structures support ing the detectors. In this case , the thermal management can be achieved either with light cooling pipes and thin plates or with a network of microchannels embedded in thin strips of silicon or polyimide . Both configuratio ns are being investigated in the context of the 2018 upgrade program of the ALICE Inner Tracking System (ITS). Moreover, it is also possible to use a s ilicon microchannel cooling device itself as structural support for the detectors and electronics. Such a configur ation has been adopted by the NA62 collaboration for the ir GigaTracKer (GTK) as well as by the LHCb collaboration for the 2018 major upgrade of...

  4. Simulation of Desiccant Cooling

    Directory of Open Access Journals (Sweden)

    Kamaruddin A.

    2017-06-01

    Full Text Available Desiccant cooling system has been an attractive topic for study lately, due to its environmentally friendly nature. It also consume less electricity and capable to be operated without refrigerant. A simulation study was conducted using 1.5 m long ducting equipped with one desiccant wheel, one sensible heat exchanger wheel, one evaporative cooling chamber and two blowers and one electric heater. The simulation study used 8.16 m/s primary air, the drying coefficient from desiccant wheel, k1=2.1 (1/s, mass transfer coefficient in evaporative cooling, k2=1.2 kg vapor/s, heat transfer coefficient in desiccant wheel, h1=4.5 W/m2 oC, and heat transfer coefficient in sensible heat exchanger wheel h2= 4.5 W/m2 oC. The simulation results show that the final temperature before entering into the air conditioning room was 25 oC and RH of 65 %, were in accordance with the Indonesian comfort index.

  5. Ultraefficient Cooling of Resonators: Beating Sideband Cooling with Quantum Control

    Science.gov (United States)

    Wang, Xiaoting; Vinjanampathy, Sai; Strauch, Frederick; Jacobs, Kurt

    2012-02-01

    There is presently a great deal of interest in cooling high-frequency micro- and nano-mechanical oscillators to their ground states. The present state of the art in cooling mechanical resonators is a version of sideband cooling, which was originally developed in the context of cooling trapped ions. Here we present a method based on quantum control that uses the same configuration as sideband cooling--coupling the resonator to be cooled to a second microwave (or optical) auxiliary resonator--but will cool significantly colder. This is achieved by applying optimal control and varying the strength of the coupling between the two resonators over a time on the order of the period of the mechanical resonator. As part of our analysis, we also obtain a method for fast, high-fidelity quantum information transfer between resonators.

  6. Cooling lubricants; Kuehlschmierstoffe

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, W. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Breuer, D. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Blome, H. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Deininger, C. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Hahn, J.U. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Kleine, H. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Nies, E. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Pflaumbaum, W. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Stockmann, R. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Willert, G. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Sonnenschein, G. [Maschinenbau- und Metall-Berufsgenossenschaft, Duesseldorf (Germany)

    1996-08-01

    As a rule, the base substances used are certain liquid hydrocarbons from mineral oils as well as from native and synthetic oils. Through the addition of further substances the cooling lubricant takes on the particular qualities required for the use in question. Employees working with cooling lubricants are exposed to various hazards. The assessment of the concentrations at the work station is carried out on the basis of existing technical rules for contact with hazardous substances. However, the application/implementation of compulsory investigation and supervision in accordance with these rules is made difficult by the fact that cooling lubricants are, as a rule, made up of complicated compound mixtures. In addition to protecting employees from exposure to mists and vapours from the cooling lubricants, protection for the skin is also of particular importance. Cooling lubricants should not, if at all possible, be brought into contact with the skin. Cleansing the skin and skin care is just as important as changing working clothes regularly, and hygiene and cleanliness at the workplace. Unavoidable emissions are to be immediately collected at the point where they arise or are released and safely disposed of. This means taking into account all sources of emissions. The programme presented in this report therefore gives a very detailed account of the individual protective measures and provides recommendations for the design of technical protection facilities. (orig./MG) [Deutsch] Als Basisstoffe dienen in der Regel bestimmte fluessige Kohlenwasserstoffverbindungen aus Mineraloelen sowie aus nativen oder synthetischen Oelen. Durch die Zugabe von weiteren Stoffen erlangt der Kuehlschmierstoff seine fuer den jeweiligen Anwendungsabfall geforderten Eigenschaften. Beschaeftigte, die mit Kuehlschmierstoffen umgehen, sind unterschiedliche Gefahren ausgesetzt. Die Beurteilung der Kuehlschmierstoffkonzentrationen in der Luft am Arbeitsplatz erfolgt auf der Grundlage bestehender

  7. MHD-, ships-, jet engine unit consisting of electrochemical cells producing hydrogen, magneto-caloric hydrogen liquefier, liquid hydrogen-cooled high temperature superconductor-, MHD-, jet engine, liquid hydrogen internal combustion engine as high temperature-, superconductor-, generator-drive. High temperature superconductor coil and permanent magnet superconductor hollow cylinder as battery. MHD-Schiffs-Strahltriebwerks-Aggregat bestehend aus Wasserstoff-produzierenden elektrochemischen Solarzellen, magnetokalorischem Wasserstoffverfluessiger, Fluessigwasserstoff gekuehltem Hochtemperatur-Supraleiter-MHD-Strahltriebwerk, Fluessigwasserstoff-Verbrennungsmotor als Hochtemperatur-Supraleiter-Generator-Antrieb, Hochtemperatur-Supraleiter-Spule und permanentmagnetischem Supraleiter-Hohlzylinder als Akku

    Energy Technology Data Exchange (ETDEWEB)

    Berling, E.

    1991-05-02

    MHD-, ships-, jet engine-unit consisting of electrochemical cells producing hydrogen, magneto-caloric hydrogen liquifier, liquid hydrogen-cooled high temperature superconductor-, MHD-, jet engine, liquid hydrogen internal combustion engine as high temperature-, superconductor-, generator-drive. High temperature superconductor coil and permanent magnet superconductor hollow cylinder as battery. Ships water jet engines with magneto hydrodynamic (MHD) low temperature superconductor drive are known. The invention of the ceramic high temperature superconductor MHD drive, which is cooled with liquid hydrogen. The hydrogen is obtained electro-chemically directly from seawater, and is liquified magneto-calorically. The high temperature superconductor elements of the engine, liquifier, generator, storage coil, permanent magnet hollow cylinder store are coupled by a common liquid hydrogen cooling circuit. The internal combustion engine driving the generator is fuelled by the same liquid hydrogen by which the high temperature superconductor elements are cooled.

  8. Weighing Ultra-Cool Stars

    Science.gov (United States)

    2004-05-01

    Large Ground-Based Telescopes and Hubble Team-Up to Perform First Direct Brown Dwarf Mass Measurement [1] Summary Using ESO's Very Large Telescope at Paranal and a suite of ground- and space-based telescopes in a four-year long study, an international team of astronomers has measured for the first time the mass of an ultra-cool star and its companion brown dwarf. The two stars form a binary system and orbit each other in about 10 years. The team obtained high-resolution near-infrared images; on the ground, they defeated the blurring effect of the terrestrial atmosphere by means of adaptive optics techniques. By precisely determining the orbit projected on the sky, the astronomers were able to measure the total mass of the stars. Additional data and comparison with stellar models then yield the mass of each of the components. The heavier of the two stars has a mass around 8.5% of the mass of the Sun and its brown dwarf companion is even lighter, only 6% of the solar mass. Both objects are relatively young with an age of about 500-1,000 million years. These observations represent a decisive step towards the still missing calibration of stellar evolution models for very-low mass stars. PR Photo 19a/04: Orbit of the ultra-cool stars in 2MASSW J0746425+2000321. PR Photo 19b/04: Animated Gif of the orbital motion. Telephone number star Even though astronomers have found several hundreds of very low mass stars and brown dwarfs, the fundamental properties of these extreme objects, such as masses and surface temperatures, are still not well known. Within the cosmic zoo, these ultra-cool stars represent a class of "intermediate" objects between giant planets - like Jupiter - and "normal" stars less massive than our Sun, and to understand them well is therefore crucial to the field of stellar astrophysics. The problem with these ultra-cool stars is that contrary to normal stars that burn hydrogen in their central core, no unique relation exists between the luminosity of the

  9. Integrated numerical methods for hypersonic aircraft cooling systems analysis

    Science.gov (United States)

    Petley, Dennis H.; Jones, Stuart C.; Dziedzic, William M.

    1992-01-01

    Numerical methods have been developed for the analysis of hypersonic aircraft cooling systems. A general purpose finite difference thermal analysis code is used to determine areas which must be cooled. Complex cooling networks of series and parallel flow can be analyzed using a finite difference computer program. Both internal fluid flow and heat transfer are analyzed, because increased heat flow causes a decrease in the flow of the coolant. The steady state solution is a successive point iterative method. The transient analysis uses implicit forward-backward differencing. Several examples of the use of the program in studies of hypersonic aircraft and rockets are provided.

  10. Laser Cooling of Molecular Anions

    CERN Document Server

    Yzombard, Pauline; Gerber, Sebastian; Doser, Michael; Comparat, Daniel

    2015-01-01

    We propose a scheme for laser cooling of negatively charged molecules. We briefly summarise the requirements for such laser cooling and we identify a number of potential candidates. A detailed computation study with C$\\_2^-$, the most studied molecular anion, is carried out. Simulations of 3D laser cooling in a gas phase show that this molecule could be cooled down to below 1 mK in only a few tens of milliseconds, using standard lasers. Sisyphus cooling, where no photo-detachment process is present, as well as Doppler laser cooling of trapped C$\\_2^-$, are also simulated. This cooling scheme has an impact on the study of cold molecules, molecular anions, charged particle sources and antimatter physics.

  11. Laser cooling of molecular anions.

    Science.gov (United States)

    Yzombard, Pauline; Hamamda, Mehdi; Gerber, Sebastian; Doser, Michael; Comparat, Daniel

    2015-05-29

    We propose a scheme for laser cooling of negatively charged molecules. We briefly summarize the requirements for such laser cooling and we identify a number of potential candidates. A detailed computation study with C_{2}^{-}, the most studied molecular anion, is carried out. Simulations of 3D laser cooling in a gas phase show that this molecule could be cooled down to below 1 mK in only a few tens of milliseconds, using standard lasers. Sisyphus cooling, where no photodetachment process is present, as well as Doppler laser cooling of trapped C_{2}^{-}, are also simulated. This cooling scheme has an impact on the study of cold molecules, molecular anions, charged particle sources, and antimatter physics.

  12. Conjugate heat transfer investigation on the cooling performance of air cooled turbine blade with thermal barrier coating

    Science.gov (United States)

    Ji, Yongbin; Ma, Chao; Ge, Bing; Zang, Shusheng

    2016-08-01

    A hot wind tunnel of annular cascade test rig is established for measuring temperature distribution on a real gas turbine blade surface with infrared camera. Besides, conjugate heat transfer numerical simulation is performed to obtain cooling efficiency distribution on both blade substrate surface and coating surface for comparison. The effect of thermal barrier coating on the overall cooling performance for blades is compared under varied mass flow rate of coolant, and spatial difference is also discussed. Results indicate that the cooling efficiency in the leading edge and trailing edge areas of the blade is the lowest. The cooling performance is not only influenced by the internal cooling structures layout inside the blade but also by the flow condition of the mainstream in the external cascade path. Thermal barrier effects of the coating vary at different regions of the blade surface, where higher internal cooling performance exists, more effective the thermal barrier will be, which means the thermal protection effect of coatings is remarkable in these regions. At the designed mass flow ratio condition, the cooling efficiency on the pressure side varies by 0.13 for the coating surface and substrate surface, while this value is 0.09 on the suction side.

  13. Process integration: Cooling water systems design

    CSIR Research Space (South Africa)

    Gololo, KV

    2010-10-01

    Full Text Available This paper presents a technique for grassroot design of cooling water system for wastewater minimization which incorporates the performances of the cooling towers involved. The study focuses mainly on cooling systems consisting of multiple cooling...

  14. Cooling water systems design using process integration

    CSIR Research Space (South Africa)

    Gololo, KV

    2010-09-01

    Full Text Available Cooling water systems are generally designed with a set of heat exchangers arranged in parallel. This arrangement results in higher cooling water flowrate and low cooling water return temperature thus reducing cooling tower efficiency. Previous...

  15. Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air

    Science.gov (United States)

    Milman, O. O.; Ptakhin, A. V.; Kondratev, A. V.; Shifrin, B. A.; Yankov, G. G.

    2016-05-01

    The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed.

  16. Solar heating and cooling.

    Science.gov (United States)

    Duffie, J A; Beckman, W A

    1976-01-16

    We have adequate theory and engineering capability to design, install, and use equipment for solar space and water heating. Energy can be delivered at costs that are competitive now with such high-cost energy sources as much fuel-generated, electrical resistance heating. The technology of heating is being improved through collector developments, improved materials, and studies of new ways to carry out the heating processes. Solar cooling is still in the experimental stage. Relatively few experiments have yielded information on solar operation of absorption coolers, on use of night sky radiation in locations with clear skies, on the combination of a solar-operated Rankine engine and a compression cooler, and on open cycle, humidification-dehumidification systems. Many more possibilities for exploration exist. Solar cooling may benefit from collector developments that permit energy delivery at higher temperatures and thus solar operation of additional kinds of cycles. Improved solar cooling capability can open up new applications of solar energy, particularly for larger buildings, and can result in markets for retrofitting existing buildings. Solar energy for buildings can, in the next decade, make a significant contribution to the national energy economy and to the pocketbooks of many individual users. very large-aggregate enterprises in manufacture, sale, and installation of solar energy equipment can result, which can involve a spectrum of large and small businesses. In our view, the technology is here or will soon be at hand; thus the basic decisions as to whether the United States uses this resource will be political in nature.

  17. Design,Simulation and Test for Double Focusing Si Monochromator of Neutron Residual Stress Diff ractometer%中子应力谱仪双聚焦 Si 单色器设计、模拟与测试

    Institute of Scientific and Technical Information of China (English)

    胡瑞; 刘蕴韬; 王玮; 刘中孝; 李峻宏; 高建波; 王洪立; 陈东风

    2015-01-01

    The double focusing Si monochromator was designed ,simulated and tested for the neutron residual stress diffractometer on China Advanced Research Reactor .T he optimal vertical curvature and the optimal thickness of Si wafers were obtained by SIMRES simulation program .In addition ,the figure of merit in dependence on the scattering angle ,monochromator horizontal curvature and wavelength was also deter‐mined by this program . The neutron beam test results indicate that the intensity of neutron increases by 15 times by using double focusing Si monochromator in comparison with Cu monochromator .%本文对中国先进研究堆中子应力谱仪使用的双聚焦 Si单色器进行了设计、模拟和测试。采用SIM RES模拟程序确定了单色器垂直曲率及Si片厚度的最优值,并得到品质因数与散射角、单色器水平曲率和波长的依赖关系。实际测试结果表明,与平板Cu单色器相比,使用双聚焦Si单色器样品处中子强度提高了15倍。

  18. Laser Cooling of Solids

    Science.gov (United States)

    2009-01-01

    observed in a range of glasses and crystals doped with Yb3+ (ZBLANP [19–22], ZBLAN [23,24], CNBZn [9,25] BIG [25, 26], KGd(WO4)2 [9], KY(WO4)2 [9], YAG [27...Yb3+-doped fluorozirconate glass ZBLAN , Phys. Rev. B 75, 144302 (2007). [40] C. W. Hoyt, Laser Cooling in Thulium-doped Solids, Ph. D. Thesis...date, optical refrigeration research has been confined to glasses and crystals doped with rare- earth elements and direct-band semiconductors such as

  19. High-Pressure-Hydrogen-Induced Spin Reconfiguration in GdFe2 Observed by 57Fe-Polarized Synchrotron Radiation Mössbauer Spectroscopy with Nuclear Bragg Monochromator

    Science.gov (United States)

    Mitsui, Takaya; Imai, Yasuhiko; Hirao, Naohisa; Matsuoka, Takahiro; Nakamura, Yumiko; Sakaki, Kouji; Enoki, Hirotoshi; Ishimatsu, Naoki; Masuda, Ryo; Seto, Makoto

    2016-12-01

    57Fe-polarized synchrotron radiation Mössbauer spectroscopy (PSRMS) with an X-ray phase plate and a nuclear Bragg monochromator was used to study ferrimagnetic GdFe2 in high-pressure hydrogen. The pressure-dependent spectra clearly showed a two-step magnetic transition of GdFe2. 57Fe-PSRMS with circular polarization gave direct evidence that the Fe moment was directed parallel to the net magnetization of the GdFe2 hydride at 20 GPa. This spin configuration was opposite to that of the initial GdFe2, suggesting an extreme weakening of the antiferromagnetic interaction between Fe and Gd. 57Fe-PSRMS enables the characterization of the nonuniform properties of iron-based polycrystalline powder alloys. The excellent applicability of 57Fe-PSRMS covers a wide range of scientific fields.

  20. A table-top monochromator for tunable femtosecond XUV pulses generated in a semi-infinite gas cell: Experiment and simulations.

    Science.gov (United States)

    von Conta, A; Huppert, M; Wörner, H J

    2016-07-01

    We present a new design of a time-preserving extreme-ultraviolet (XUV) monochromator using a semi-infinite gas cell as a source. The performance of this beamline in the photon-energy range of 20 eV-42 eV has been characterized. We have measured the order-dependent XUV pulse durations as well as the flux and the spectral contrast. XUV pulse durations of ≤40 fs using 32 fs, 800 nm driving pulses were measured on the target. The spectral contrast was better than 100 over the entire energy range. A simple model based on the strong-field approximation is presented to estimate different contributions to the measured XUV pulse duration. On-axis phase-matching calculations are used to rationalize the variation of the photon flux with pressure and intensity.

  1. A compact low cost “master–slave” double crystal monochromator for x-ray cameras calibration of the Laser MégaJoule Facility

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr; Prévot, V.

    2014-12-21

    The Alternative Energies and Atomic Energy Commission (CEA-CESTA, France) built a specific double crystal monochromator (DCM) to perform calibration of x-ray cameras (CCD, streak and gated cameras) by means of a multiple anode diode type x-ray source for the MégaJoule Laser Facility. This DCM, based on pantograph geometry, was specifically modeled to respond to relevant engineering constraints and requirements. The major benefits are mechanical drive of the second crystal on the first one, through a single drive motor, as well as compactness of the entire device. Designed for flat beryl or Ge crystals, this DCM covers the 0.9–10 keV range of our High Energy X-ray Source. In this paper we present the mechanical design of the DCM, its features quantitatively measured and its calibration to finally provide monochromatized spectra displaying spectral purities better than 98%.

  2. Cooling load across glazed building surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Aydinli, S.; Krochmann, J. (Technische Univ. Berlin (Germany, F.R.). Inst. fuer Lichttechnik)

    1980-05-01

    It is only possible to build favourably with regard to costs and energy requirements, if the windows which are required for the direct visual contact between the inner and outer space are favourably selected with regard to the thermal loading of the internal space during the summer months and the heat losses during the cold season of the year. To achieve this an exact calculation of the partial cooling load is required, which is caused by the solar radiation entering into the inner space through the glazed building surfaces. Described are the items for the calculation of the magnitude of the radiation which defines this part of the cooling load on to any inclined surface and the influence of the properties of the glazing.

  3. THE COOLING OF CORONAL PLASMAS. IV. CATASTROPHIC COOLING OF LOOPS

    Energy Technology Data Exchange (ETDEWEB)

    Cargill, P. J. [Space and Atmospheric Physics, The Blackett Laboratory, Imperial College, London SW7 2BW (United Kingdom); Bradshaw, S. J., E-mail: p.cargill@imperial.ac.uk [Department of Physics and Astronomy, Rice University, Houston, TX 77005 (United States)

    2013-07-20

    We examine the radiative cooling of coronal loops and demonstrate that the recently identified catastrophic cooling is due to the inability of a loop to sustain radiative/enthalpy cooling below a critical temperature, which can be >1 MK in flares, 0.5-1 MK in active regions, and 0.1 MK in long tenuous loops. Catastrophic cooling is characterized by a rapid fall in coronal temperature, while the coronal density changes by a small amount. Analytic expressions for the critical temperature are derived and show good agreement with numerical results. This effect considerably limits the lifetime of coronal plasmas below the critical temperature.

  4. Cooling Performance of an Impingement Cooling Device Combined with Pins

    Institute of Scientific and Technical Information of China (English)

    Dongliang QUAN; Songling LIU; Jianghai LI; Gaowen LIU

    2005-01-01

    Experimental study and one dimensional model analysis were conducted to investigate cooling performance of an integrated impingement and pin fin cooling device. A typical configuration specimen was made and tested in a large scale low speed closed-looped wind tunnel. Detailed two-dimensional contour maps of the temperature and cooling effectiveness were obtained for different pressure ratios and therefore different coolant flow-rates through the tested specimen. The experimental results showed that very high cooling effectiveness can be achieved by this cooling device with relatively small amount of coolant flow. Based on the theory of transpiration cooling in porous material, a one dimensional heat transfer model was established to analyze the effect of various parameters on cooling effectiveness. It was found from this model that the variation of heat transfer on the gas side, including heat transfer coefficient and film cooling effectiveness, of the specimen created much more effect on its cooling effectiveness than that of the coolant side. The predictions of the one-dimensional mode were compared and agreed well with the experimental data.

  5. Cooling load optimization of an irreversible refrigerator with combined heat transfer

    Directory of Open Access Journals (Sweden)

    M. El Haj Assad

    2013-01-01

    Full Text Available In this work a mathematical model to study the performance of an irreversible refrigerator has been presented with the consideration of heat exchange by combined convection and radiation. The external irreversibility effects due to finite rate heat transfer as well as the effects of internal dissipations have been considered in the analysis. The relation between the cooling load and the coefficient of performance of the refrigerator has been derived. Furthermore an expression for the maximum cooling rate has been derived. The parameters that affect the cooling load have been investigated. The cooling load has been discussed and the effect of internal irreversibility has been investigated.

  6. Fluid Atmospheres of Cool White Dwarfs

    Science.gov (United States)

    Kowalski, P.

    2004-05-01

    We investigate quantitatively for the first time the dense fluid effects in the surface layers of very cool white dwarf stars. In general, the gas is so tenuous in stellar atmospheres that non-ideal gas effects are negligible. One important exception are the atmospheres of cool white dwarfs, especially those rich in helium, where temperature varies from 1000K to 10000K, the densities reach values as large as 2 \\ g/cm3, and pressure is as high as 1 \\ Mbar. Under such conditions, the atmosphere is no longer an ideal gas, but must be treated as a dense fluid. New physical effects occur. Helium atoms become strongly correlated and refraction effects are present. Opacity sources, such as He- free-free absorption, require different treatment from diluted gases. The refractive index departs from unity and can be as large as 1.35. We present the first solution of the radiative transfer in refractive atmospheres of cool white dwarfs. The importance of total internal reflection is discussed. We find that through the constraint of the radiative equilibrium, the total internal reflection warms the white dwarf atmosphere in optically thin surface regions. Strong curvature of rays results in a much weakened limb darkening effect. This preliminary result suggests that dense fluid effects may have a significant impact on studies of very cool white dwarf stars. This research was supported by NSF grant AST97-31438, NASA grant NAG5-8906, and by the United States Department of Energy under contract W-7405-ENG-36.

  7. Emerging Two-Phase Cooling Technologies for Power Electronic Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, J.S.

    2005-08-17

    In order to meet the Department of Energy's (DOE's) FreedomCAR and Vehicle Technologies (FVCT) goals for volume, weight, efficiency, reliability, and cost, the cooling of the power electronic devices, traction motors, and generators is critical. Currently the power electronic devices, traction motors, and generators in a hybrid electric vehicle (HEV) are primarily cooled by water-ethylene glycol (WEG) mixture. The cooling fluid operates as a single-phase coolant as the liquid phase of the WEG does not change to its vapor phase during the cooling process. In these single-phase systems, two cooling loops of WEG produce a low temperature (around 70 C) cooling loop for the power electronics and motor/generator, and higher temperature loop (around 105 C) for the internal combustion engine. There is another coolant option currently available in automobiles. It is possible to use the transmission oil as a coolant. The oil temperature exists at approximately 85 C which can be utilized to cool the power electronic and electrical devices. Because heat flux is proportional to the temperature difference between the device's hot surface and the coolant, a device that can tolerate higher temperatures enables the device to be smaller while dissipating the same amount of heat. Presently, new silicon carbide (SiC) devices and high temperature direct current (dc)-link capacitors, such as Teflon capacitors, are available but at significantly higher costs. Higher junction temperature (175 C) silicon (Si) dies are gradually emerging in the market, which will eventually help to lower hardware costs for cooling. The development of high-temperature devices is not the only way to reduce device size. Two-phase cooling that utilizes the vaporization of the liquid to dissipate heat is expected to be a very effective cooling method. Among two-phase cooling methods, different technologies such as spray, jet impingement, pool boiling and submersion, etc. are being developed. The

  8. Electronic cooling using thermoelectric devices

    Energy Technology Data Exchange (ETDEWEB)

    Zebarjadi, M., E-mail: m.zebarjadi@rutgers.edu [Department of Mechanical and Aerospace Engineering, Rutgers University, Piscataway, New Jersey 08854 (United States); Institute of Advanced Materials, Devices, and Nanotechnology, Rutgers University, Piscataway, New Jersey 08854 (United States)

    2015-05-18

    Thermoelectric coolers or Peltier coolers are used to pump heat in the opposite direction of the natural heat flux. These coolers have also been proposed for electronic cooling, wherein the aim is to pump heat in the natural heat flux direction and from hot spots to the colder ambient temperature. In this manuscript, we show that for such applications, one needs to use thermoelectric materials with large thermal conductivity and large power factor, instead of the traditionally used high ZT thermoelectric materials. We further show that with the known thermoelectric materials, the active cooling cannot compete with passive cooling, and one needs to explore a new set of materials to provide a cooling solution better than a regular copper heat sink. We propose a set of materials and directions for exploring possible materials candidates suitable for electronic cooling. Finally, to achieve maximum cooling, we propose to use thermoelectric elements as fins attached to copper blocks.

  9. Optical stochastic cooling in Tevatron

    CERN Document Server

    Lebedev, V

    2012-01-01

    Intrabeam scattering is the major mechanism resulting in a growth of beam emittances and fast luminosity degradation in the Tevatron. As a result in the case of optimal collider operation only about 40% of antiprotons are used to the store end and the rest are discarded. Beam cooling is the only effective remedy to increase the particle burn rate and, consequently, the luminosity. Unfortunately neither electron nor stochastic cooling can be effective at the Tevatron energy and bunch density. Thus the optical stochastic cooling (OSC) is the only promising technology capable to cool the Tevatron beam. Possible ways of such cooling implementation in the Tevatron and advances in the OSC cooling theory are discussed in this paper. The technique looks promising and potentially can double the average Tevatron luminosity without increasing its peak value and the antiproton production.

  10. Electron Cooling Experiments in CSR

    CERN Document Server

    Xiaodong, Yang

    2011-01-01

    The six species heavy ion beam was accumulated with the help of electron cooling in the main ring of Cooler Storage Ring of Heavy Ion Research Facility in Lanzhou(HIRFL-CSR), the ion beam accumulation dependence on the parameters of cooler was investigated experimentally. The 400MeV/u 12C6+ and 200MeV/u 129Xe54+ was stored and cooled in the experimental ring CSRe, the cooling force was measured in different condition.

  11. Radiative cooling for thermophotovoltaic systems

    Science.gov (United States)

    Zhou, Zhiguang; Sun, Xingshu; Bermel, Peter

    2016-09-01

    Radiative cooling has recently garnered a great deal of attention for its potential as an alternative method for photovoltaic thermal management. Here, we will consider the limits of radiative cooling for thermal management of electronics broadly, as well as a specific application to thermal power generation. We show that radiative cooling power can increase rapidly with temperature, and is particularly beneficial in systems lacking standard convective cooling. This finding indicates that systems previously operating at elevated temperatures (e.g., 80°C) can be passively cooled close to ambient under appropriate conditions with a reasonable cooling area. To examine these general principles for a previously unexplored application, we consider the problem of thermophotovoltaic (TPV) conversion of heat to electricity via thermal radiation illuminating a photovoltaic diode. Since TPV systems generally operate in vacuum, convective cooling is sharply limited, but radiative cooling can be implemented with proper choice of materials and structures. In this work, realistic simulations of system performance are performed using the rigorous coupled wave analysis (RCWA) techniques to capture thermal emitter radiation, PV diode absorption, and radiative cooling. We subsequently optimize the structural geometry within realistic design constraints to find the best configurations to minimize operating temperature. It is found that low-iron soda-lime glass can potentially cool the PV diode by a substantial amount, even to below ambient temperatures. The cooling effect can be further improved by adding 2D-periodic photonic crystal structures. We find that the improvement of efficiency can be as much as an 18% relative increase, relative to the non-radiatively cooled baseline, as well as a potentially significant improvement in PV diode lifetime.

  12. To Be Cool or Uncool?

    Institute of Scientific and Technical Information of China (English)

    袁会珍

    2007-01-01

    The western world has always been divided into two types of people-the cool and the uncool. It is a division that __1__ in school. The cool kids are good at __2__. They are __3__ with the opposite sex. They are good-looking and people want to __4__ their style. They can do their homework but they don't make a big effort. That would __5__ be cool.

  13. Electron cooling experiments in CSR

    Institute of Scientific and Technical Information of China (English)

    PARKHOMCHUK; Vasily; REVA; Vladimir

    2011-01-01

    The six species heavy ion beam was accumulated with the help of electron cooling in the main ring of Cooler Storage Ring of Heavy Ion Research Facility in Lanzhou (HIRFL-CSR). The ion beam accumulation dependence on the parameters of cooler was investigated experimentally. The 400 MeV/u 12C6+ and 200 MeV/u 129Xe54+ were stored and cooled in the experimental ring CSRe, and the cooling force was measured in different conditions.

  14. Workshop 4 Converter cooling & recuperation

    Science.gov (United States)

    Iles, Peter; Hindman, Don

    1995-01-01

    Cooling the PV converter increases the overall TPV system efficiency, and more than offsets the losses incurred in providing cooling systems. Convective air flow methods may be sufficient, and several standard water cooling systems, including thermo-syphon radiators, capillary pumps or microchannel plates, are available. Recuperation is used to increase system efficiency, rather than to increase the emitter temperature. Recuperators operating at comparable high temperatures, such as in high temperature turbines have worked effectively.

  15. Stochastic cooling technology at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Pasquinelli, R.J. E-mail: pasquin@fnal.gov

    2004-10-11

    The first antiproton cooling systems were installed and commissioned at Fermilab in 1984-1985. In the interim period, there have been several major upgrades, system improvements, and complete reincarnation of cooling systems. This paper will present some of the technology that was pioneered at Fermilab to implement stochastic cooling systems in both the Antiproton Source and Recycler accelerators. Current performance data will also be presented.

  16. Direct cooled power electronics substrate

    Science.gov (United States)

    Wiles, Randy H [Powell, TN; Wereszczak, Andrew A [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Lowe, Kirk T [Knoxville, TN

    2010-09-14

    The disclosure describes directly cooling a three-dimensional, direct metallization (DM) layer in a power electronics device. To enable sufficient cooling, coolant flow channels are formed within the ceramic substrate. The direct metallization layer (typically copper) may be bonded to the ceramic substrate, and semiconductor chips (such as IGBT and diodes) may be soldered or sintered onto the direct metallization layer to form a power electronics module. Multiple modules may be attached to cooling headers that provide in-flow and out-flow of coolant through the channels in the ceramic substrate. The modules and cooling header assembly are preferably sized to fit inside the core of a toroidal shaped capacitor.

  17. Cooling clothing utilizing water evaporation

    DEFF Research Database (Denmark)

    Sakoi, Tomonori; Tominaga, Naoto; Melikov, Arsen Krikor

    2014-01-01

    We developed cooling clothing that utilizes water evaporation to cool the human body and has a mechanism to control the cooling intensity. Clean water was supplied to the outer surface of the T-shirt of the cooling clothing, and a small fan was used to enhance evaporation on this outer surface...... temperature ranging from 27.4 to 30.7 °C to establish a suitable water supply control method. A water supply control method that prevents water accumulation in the T-shirt and water dribbling was validated; this method is established based on the concept of the water evaporation capacity under the applied...

  18. Regeneratively Cooled Porous Media Jacket

    Science.gov (United States)

    Mungas, Greg (Inventor); Fisher, David J. (Inventor); London, Adam Pollok (Inventor); Fryer, Jack Merrill (Inventor)

    2013-01-01

    The fluid and heat transfer theory for regenerative cooling of a rocket combustion chamber with a porous media coolant jacket is presented. This model is used to design a regeneratively cooled rocket or other high temperature engine cooling jacket. Cooling jackets comprising impermeable inner and outer walls, and porous media channels are disclosed. Also disclosed are porous media coolant jackets with additional structures designed to transfer heat directly from the inner wall to the outer wall, and structures designed to direct movement of the coolant fluid from the inner wall to the outer wall. Methods of making such jackets are also disclosed.

  19. Cooling Load Estimation in the Building Based On Heat Sources

    Science.gov (United States)

    Chairani; Sulistyo, S.; Widyawan

    2017-05-01

    Heating, ventilation and air conditioning (HVAC) is the largest source of energy consumption. In this research, we discuss cooling load in the room by considering the different heat source and the number of occupancy. Energy cooling load is affected by external and internal heat sources. External cooling load in this discussion include convection outdoor/exterior using the DOE-2 algorithm, calculation of heat using Thermal Analysis Research Program (TARP), and Conduction Transfer Function (CTF). The internal cooling load is calculated based on the activity of the occupants in the office, a number of occupants, heat gain from lighting, and heat gain from electrics equipment. Weather data used is Surakarta weather and design day used is Jakarta design day. We use the ASHRAE standard for building materials and the metabolic of occupants while on the activity. The results show that the number of occupancies have an influence of cooling load. A large number of occupancy will cause the cooling load is great as well.

  20. Fluid cooled electrical assembly

    Science.gov (United States)

    Rinehart, Lawrence E.; Romero, Guillermo L.

    2007-02-06

    A heat producing, fluid cooled assembly that includes a housing made of liquid-impermeable material, which defines a fluid inlet and a fluid outlet and an opening. Also included is an electrical package having a set of semiconductor electrical devices supported on a substrate and the second major surface is a heat sink adapted to express heat generated from the electrical apparatus and wherein the second major surface defines a rim that is fit to the opening. Further, the housing is constructed so that as fluid travels from the fluid inlet to the fluid outlet it is constrained to flow past the opening thereby placing the fluid in contact with the heat sink.

  1. ATLAS' major cooling project

    CERN Multimedia

    2005-01-01

    In 2005, a considerable effort has been put into commissioning the various units of ATLAS' complex cryogenic system. This is in preparation for the imminent cooling of some of the largest components of the detector in their final underground configuration. The liquid helium and nitrogen ATLAS refrigerators in USA 15. Cryogenics plays a vital role in operating massive detectors such as ATLAS. In many ways the liquefied argon, nitrogen and helium are the life-blood of the detector. ATLAS could not function without cryogens that will be constantly pumped via proximity systems to the superconducting magnets and subdetectors. In recent weeks compressors at the surface and underground refrigerators, dewars, pumps, linkages and all manner of other components related to the cryogenic system have been tested and commissioned. Fifty metres underground The helium and nitrogen refrigerators, installed inside the service cavern, are an important part of the ATLAS cryogenic system. Two independent helium refrigerators ...

  2. Air cooled absorption chillers for solar cooling applications

    Science.gov (United States)

    Biermann, W. J.; Reimann, R. C.

    1982-03-01

    The chemical composition of a 'best' absorption refrigerant system is identified, and those properties of the system necessary to design hot water operated, air cooled chilling equipment are determined. Air cooled chillers from single family residential sizes into the commercial rooftop size range are designed and operated.

  3. Sub-Doppler Laser Cooling using Electromagnetically Induced Transparency

    CERN Document Server

    He, Peiru; Anderson, Dana Z; Rey, Ana Maria; Holland, Murray

    2016-01-01

    We propose a sub-Doppler laser cooling mechanism that takes advantage of the unique spectral features and extreme dispersion generated by the phenomenon of electromagnetically induced transparency (EIT). EIT is a destructive quantum interference phenomenon experienced by atoms with multiple internal quantum states when illuminated by laser fields with appropriate frequencies. By detuning the lasers slightly from the "dark resonance", we observe that, within the transparency window, atoms can be subject to a strong viscous force, while being only slightly heated by the diffusion caused by spontaneous photon scattering. In contrast to other laser cooling schemes, such as polarization gradient cooling or EIT-sideband cooling, no external magnetic field or strong external confining potential is required. Using a semiclassical approximation, we derive analytically quantitative expressions for the steady-state temperature, which is confirmed by full quantum mechanical numerical simulations. We find that the lowest ...

  4. Solar heating cooling. Preparation of possible participation in IEA, Solar Heating Cooling Task 25; Solvarmedrevet koeling. Forberedelse af evt. deltagelse i IEA, Solar Heating Cooling Task 25

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the Danish solar heating industries it is interesting to discuss the domestic market possibilities and the export possibilities for solar heating cooling systems. The Danish solar heating sector also wants to participate in the international collaboration within IEA Solar Heating and Cooling Task 25 'Solar Assisted Air Conditioning of Buildings'. The Danish Energy Agency therefore has granted means for this project to discuss: The price of cooling for 3 different solar cooling methods (absorption cooling, desiccant cooling and ejector cooling); Market possibilities in Denmark and abroad; The advantages by Danish participation in IEA Task 25. The task has been solved through literature studies to establish status for the 3 technologies. It turned out that ejector cooling by low temperatures (85 deg. C from the solar collector) exists as pilot plants in relation to district heating, but is still not commercial accessible. Desiccant cooling, where the supplied heat has temperatures down to 55 deg. C is a well-developed technology. However only a handful of pilot plants with solar heating exists, and thus optimization relating to operation strategy and economy is on the experimental stage. Absorption cooling plants driven by solar heating are found in a large number in Japan and are also demonstrated in several other countries. The combination of absorption heating pump and solar heating is considered to be commercial accessible. Solar heating is interesting as heat source of to the exent that it can replace other sources of heat without the economy being depreciated. This can be the case in South Europe if: 1) oil or natural gas is used for heating; 2) a solar heating system already exists, e.g. for domestic water supply, and is installed so that the marginal costs by solar heating supply of the ventilation plant is reduced. All in all the above conditions mean that the market for solar heating for cooling is very limited in Europe, where almost

  5. National solar heating and cooling programs

    Energy Technology Data Exchange (ETDEWEB)

    Blum, S; Allen, J [eds.

    1979-08-01

    This document is a compilation of status reports on the national solar heating and cooling programs of seventeen countries participating in the Committee on the Challenges of Modern Society's Solar Energy Pilot Study. These reports were presented in two special sessions of the 25th Congress of the International Solar Energy Society held in May 1979, in Atlanta, Georgia, USA. This information exchange activity was part of the two-year follow up (1978-1980) of the Solar Energy Pilot Study, which ended in October 1978.

  6. AGN effect on cooling flow dynamics

    CERN Document Server

    Bibi, F Alouani; Blundell, K; Omma, H

    2007-01-01

    We analyzed the feedback of AGN jets on cooling flow clusters using three-dimensional AMR hydrodynamic simulations. We studied the interaction of the jet with the intracluster medium and creation of low X-ray emission cavities (Bubbles) in cluster plasma. The distribution of energy input by the jet into the system was quantified in its different forms, i.e. internal, kinetic and potential. We find that the energy associated with the bubbles, (pV + gamma pV/(gamma-1)), accounts for less than 10 percent of the jet energy.

  7. Focus issue introduction: optical cooling and trapping.

    Science.gov (United States)

    Neves, Antonio A R; Jones, Philip H; Luo, Le; Maragò, Onofrio M

    2015-04-20

    The year 2015 is an auspicious year for optical science, as it is being celebrated as the International Year of Light and Light-Based Technologies. This Focus Issue of the journals Optics Express and Journal of the Optical Society of America B has been organized by the OSA Technical Group on Optical Cooling and Trapping to mark this occasion, and to highlight the most recent and exciting developments in the topics covered by the group. Together this joint Focus Issue features 32 papers, including both experimental and theoretical works, which span this wide range of activities.

  8. Effects of Thermal Barrier Coatings on Approaches to Turbine Blade Cooling

    Science.gov (United States)

    Boyle, Robert J.

    2007-01-01

    Reliance on Thermal Barrier Coatings (TBC) to reduce the amount of air used for turbine vane cooling is beneficial both from the standpoint of reduced NOx production, and as a means of improving cycle efficiency through improved component efficiency. It is shown that reducing vane cooling from 10 to 5 percent of mainstream air can lead to NOx reductions of nearly 25 percent while maintaining the same rotor inlet temperature. An analysis is given which shows that, when a TBC is relied upon in the vane thermal design process, significantly less coolant is required using internal cooling alone compared to film cooling. This is especially true for small turbines where internal cooling without film cooling permits the surface boundary layer to remain laminar over a significant fraction of the vane surface.

  9. Feasibility assessment of vacuum cooling followed by immersion vacuum cooling on water-cooked pork.

    Science.gov (United States)

    Dong, Xiaoguang; Chen, Hui; Liu, Yi; Dai, Ruitong; Li, Xingmin

    2012-01-01

    Vacuum cooling followed by immersion vacuum cooling was designed to cool water-cooked pork (1.5±0.05 kg) compared with air blast cooling (4±0.5°C, 2 m/s), vacuum cooling (10 mbar) and immersion vacuum cooling. This combined cooling method was: vacuum cooling to an intermediate temperature of 25°C and then immersion vacuum cooling with water of 10°C to the final temperature of 10°C. It was found that the cooling loss of this combined cooling method was significantly lower (Pvacuum cooling. This combined cooling was faster (Pvacuum cooling in terms of cooling rate. Moreover, the pork cooled by combined cooling method had significant differences (P<0.05) in water content, color and shear force. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Proceedings of the NEACRP/IAEA Specialists meeting on the international comparison calculation of a large sodium-cooled fast breeder reactor at Argonne National Laboratory on February 7-9, 1978

    Energy Technology Data Exchange (ETDEWEB)

    LeSage, L.G.; McKnight, R.D.; Wade, D.C.; Freese, K.E.; Collins, P.J.

    1980-08-01

    The results of an international comparison calculation of a large (1250 MWe) LMFBR benchmark model are presented and discussed. Eight reactor configurations were calculated. Parameters included with the comparison were: eigenvalue, k/sub infinity/, neutron balance data, breeding reaction rate ratios, reactivity worths, central control rod worth, regional sodium void reactivity, core Doppler and effective delayed neutron fraction. Ten countries participated in the comparison, and sixteen solutions were contributed. The discussion focuses on the variation in parameter values, the degree of consistency among the various parameters and solutions, and the identification of unexpected results. The results are displayed and discussed both by individual participants and by groupings of participants (e.g., results from adjusted data sets versus non-adjusted data sets).

  11. Newton's Law of Cooling Revisited

    Science.gov (United States)

    Vollmer, M.

    2009-01-01

    The cooling of objects is often described by a law, attributed to Newton, which states that the temperature difference of a cooling body with respect to the surroundings decreases exponentially with time. Such behaviour has been observed for many laboratory experiments, which led to a wide acceptance of this approach. However, the heat transfer…

  12. Dialogues in the COOL Project

    NARCIS (Netherlands)

    Stalpers, S.I.P.; Kroeze, C.

    2013-01-01

    The Climate Options for the Long-term (COOL) Project is a participatory integrated assessment (PIA) comprising extensive dialogues at three levels: national, European and global. The objective of the COOL Project was to ‘develop strategic notions on how to achieve drastic reductions of greenhouse ga

  13. Be Cool, Man! / Jevgeni Levik

    Index Scriptorium Estoniae

    Levik, Jevgeni

    2005-01-01

    Järg 1995. aasta kriminaalkomöödiale "Tooge jupats" ("Get Shorty") : mängufilm "Be Cool, Chili Palmer on tagasi!" ("Be Cool") : režissöör F. Gary Gray, peaosades J. Travolta ja U. Thurman : USA 2005. Lisatud J. Travolta ja U. Thurmani lühiintervjuud

  14. Temperature initiated passive cooling system

    Science.gov (United States)

    Forsberg, Charles W.

    1994-01-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  15. Be Cool, Man! / Jevgeni Levik

    Index Scriptorium Estoniae

    Levik, Jevgeni

    2005-01-01

    Järg 1995. aasta kriminaalkomöödiale "Tooge jupats" ("Get Shorty") : mängufilm "Be Cool, Chili Palmer on tagasi!" ("Be Cool") : režissöör F. Gary Gray, peaosades J. Travolta ja U. Thurman : USA 2005. Lisatud J. Travolta ja U. Thurmani lühiintervjuud

  16. Dew Point Evaporative Comfort Cooling

    Science.gov (United States)

    2012-11-01

    220 Figure 140. Water-cooled chilled water plant with primary/secondary...enough to buffer the space by carrying away solar loads in unoccupied volumes, such as ceiling plenums. For rooftop installations, where ceiling...and are significant for the three-month period and generally exceed 68%. Larger chilled water plants with water-cooled condensers can operate with

  17. Triatomic molecules laser-cooled

    Science.gov (United States)

    2017-06-01

    Molecules containing three atoms have been laser-cooled to ultracold temperatures for the first time. John Doyle and colleagues at Harvard University in the US used a technique called Sisyphus cooling to chill an ensemble of about a million strontium-monohydroxide molecules to 750 μK.

  18. (International Collaboration on Advanced Neutron Sources)

    Energy Technology Data Exchange (ETDEWEB)

    Hayter, J.B.

    1990-11-08

    The International Collaboration on Advanced Neutron Sources was started about a decade ago with the purpose of sharing information throughout the global neutron community. The collaboration has been extremely successful in optimizing the use of resources, and the discussions are open and detailed, with reasons for failure shared as well as reasons for success. Although the meetings have become increasingly oriented toward pulsed neutron sources, many of the neutron instrumentation techniques, such as the development of better monochromators, fast response detectors and various data analysis methods, are highly relevant to the Advanced Neutron Source (ANS). I presented one paper on the ANS, and another on the neutron optical polarizer design work which won a 1989 R D-100 Award. I also gained some valuable design ideas, in particular for the ANS hot source, in discussions with individual researchers from Canada, Western Europe, and Japan.

  19. (International Collaboration on Advanced Neutron Sources)

    Energy Technology Data Exchange (ETDEWEB)

    Hayter, J.B.

    1990-11-08

    The International Collaboration on Advanced Neutron Sources was started about a decade ago with the purpose of sharing information throughout the global neutron community. The collaboration has been extremely successful in optimizing the use of resources, and the discussions are open and detailed, with reasons for failure shared as well as reasons for success. Although the meetings have become increasingly oriented toward pulsed neutron sources, many of the neutron instrumentation techniques, such as the development of better monochromators, fast response detectors and various data analysis methods, are highly relevant to the Advanced Neutron Source (ANS). I presented one paper on the ANS, and another on the neutron optical polarizer design work which won a 1989 R D-100 Award. I also gained some valuable design ideas, in particular for the ANS hot source, in discussions with individual researchers from Canada, Western Europe, and Japan.

  20. Heat-stop structure design with high cooling efficiency for large ground-based solar telescope.

    Science.gov (United States)

    Liu, Yangyi; Gu, Naiting; Rao, Changhui; Li, Cheng

    2015-07-20

    A heat-stop is one of the most important thermal control devices for a large ground-based solar telescope. For controlling the internal seeing effect, the temperature difference between the heat-stop and the ambient environment needs to be reduced, and a heat-stop with high cooling efficiency is required. In this paper, a novel design concept for the heat-stop, in which a multichannel loop cooling system is utilized to obtain higher cooling efficiency, is proposed. To validate the design, we analyze and compare the cooling efficiency for the multichannel and existing single-channel loop cooling system under the same conditions. Comparative results show that the new design obviously enhances the cooling efficiency of the heat-stop, and the novel design based on the multichannel loop cooling system is obviously better than the existing design by increasing the thermal transfer coefficient.

  1. A novel electronic cooling concept

    Science.gov (United States)

    Ponnappan, R.; Beam, J. E.

    Advanced electrical power conditioning systems for the More Electric Aircraft Initiative involve high currents and high voltages with the attendant waste heat generation and cooling problems. The use of solid state switching devices such as MCTs for these systems will result in power dissipation of several hundred Watts per square centimeter. Conventional forced air or low velocity single phase fluid cooling is inadequate to handle the waste heat dissipation of these high power devices. More advanced and innovative methods of cooling which can use fluids available in the aircraft and also easy to package are sought. A new approach called 'venturi flow cooling concept' is described. It is shown that localized cooling up to 200 W/sq cm is possible at the venturi throat region where the MCTs can be mounted. PAO coolant with Pr = 56 at 40 C can be conveniently used in aircraft.

  2. Laser cooling to quantum degeneracy.

    Science.gov (United States)

    Stellmer, Simon; Pasquiou, Benjamin; Grimm, Rudolf; Schreck, Florian

    2013-06-28

    We report on Bose-Einstein condensation in a gas of strontium atoms, using laser cooling as the only cooling mechanism. The condensate is formed within a sample that is continuously Doppler cooled to below 1  μK on a narrow-linewidth transition. The critical phase-space density for condensation is reached in a central region of the sample, in which atoms are rendered transparent for laser cooling photons. The density in this region is enhanced by an additional dipole trap potential. Thermal equilibrium between the gas in this central region and the surrounding laser cooled part of the cloud is established by elastic collisions. Condensates of up to 10(5) atoms can be repeatedly formed on a time scale of 100 ms, with prospects for the generation of a continuous atom laser.

  3. Clock Technology Development for the Laser Cooling and Atomic Physics (LCAP) Program

    Science.gov (United States)

    Klipstein, W. M.; Thompson, R. J.; Seidel, D. J.; Kohel, J.; Maleki, L.

    1998-01-01

    The Time and Frequency Sciences and Technology Group at Jet Propulsion Laboratory (JPL) has developed a laser cooling capability for flight and has been selected by NASA to support the Laser-Cooling and Atomic Physics (LCAP) program. Current work in the group includes design and development for tee two laser-cooled atomic clock experiments which have been selected for flight on the International Space Station.

  4. Simulating the Cooling Flow of Cool-Core Clusters

    CERN Document Server

    Li, Yuan

    2011-01-01

    We carry out high-resolution adaptive mesh refinement simulations of a cool core cluster, resolving the flow from Mpc scales down to pc scales. We do not (yet) include any AGN heating, focusing instead on cooling in order to understand how gas gets to the supermassive black hole (SMBH) at the center of the cluster. We find that, as the gas cools, the cluster develops a very flat temperature profile, undergoing a cooling catastrophe only in the central 10-100 pc of the cluster. Outside of this region, the flow is smooth, with no local cooling instabilities, and naturally produces very little low-temperature gas (below a few keV), in agreement with observations. The gas cooling in the center of the cluster rapidly forms a thin accretion disk. The amount of cold gas produced at the very center grows rapidly until a reasonable estimate of the resulting AGN heating rate (assuming even a moderate accretion efficiency) would overwhelm cooling. We argue that this naturally produces a thermostat which links the coolin...

  5. 46 CFR 153.432 - Cooling systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a manual...

  6. Convective cooling of photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Hodge, E.; Gibbons, C. [Energy Engineering Group, Mechanical Engineering Department, Cork Institute of Technology, Bishopstown, Cork (Ireland)

    2004-07-01

    Most solar cells presently on the market are based on silicon wafers, the so-called first generation technology. As this technology has matured costs have become increasingly dominated by material costs. In the last ten years, continuous work has brought the efficiency of standard cells to the 25% region. A switch to second generation or thin film technology cells now seems imminent. Thin film technology eliminates the silicon wafer and offer the prospect of reducing material and manufacturing costs, but they exhibit lower efficiencies of around 10% for a commercial device. Third generation or tandem cells are currently at a 'proof of concept' research level, with a theoretical conversion rate of 86.8% being asserted Whatever the material construction and manufacturing method of cells, the thermal effect of overheating will prevail in the semiconductor and it is accepted that a lowered temperature will bring about an increase in conversion efficiency. The aim of this project is to improve the efficiency of PV electrical output, by convectively cooling the cells through perforations in them. As the cells heat up they lose efficiency. As the panel heats up a loss in efficiency of 0.5% per C increase in temperature has been recorded. (orig.)

  7. Central cooling: absorptive chillers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-08-01

    This technology evaluation covers commercially available single-effect, lithium-bromide absorption chillers ranging in nominal cooling capacities of 3 to 1,660 tons and double-effect lithium-bromide chillers from 385 to 1,060 tons. The nominal COP measured at operating conditions of 12 psig input steam for the single-effect machine, 85/sup 0/ entering condenser water, and 44/sup 0/F exiting chilled-water, ranges from 0.6 to 0.65. The nominal COP for the double-effect machine varies from 1.0 to 1.15 with 144 psig entering steam. Data are provided to estimate absorption-chiller performance at off-nominal operating conditions. The part-load performance curves along with cost estimating functions help the system design engineer select absorption equipment for a particular application based on life-cycle costs. Several suggestions are offered which may be useful for interfacing an absorption chiller with the remaining Integrated Community Energy System. The ammonia-water absorption chillers are not considered to be readily available technology for ICES application; therefore, performance and cost data on them are not included in this evaluation.

  8. Biospheric Cooling and the Emergence of Intelligence

    Science.gov (United States)

    Schwartzman, David; Middendorf, George

    The long-term cooling history of the Earth's biosphere implies a temperature constraint on the timing of major events in biologic evolution, e.g., emergence of cyanobacteria, eucaryotes and Metazoa apparently occurred at times when temperatures were near their upper growth limits. Could biospheric cooling also have been a necessary condition for the emergence of veterbrates and their encephalization? The upper temperature limit for vertebrate growth is about 10 degrees below the limit for Metazoa (50 degrees C). Heterothermy followed by full homeothermy was likely a necessary condition for greater encephalization because of the energy requirement of larger brains. The temperature differential between an animal and a cooler environment, all other factors equal, will increase the efficiency of heat loss from the brain, but too large a differential will shift metabolic energy away from the brain to the procurement of food. Encephalization has also entailed the evolution of internal cooling mechanisms to avoid overheating the brain. The two periods of pronounced Phanerozoic cooling, the PermoCarboniferous and late Cenozoic, corresponded to the emergence of mammal-like reptiles and hominids respectively, with a variety of explanations offered for the apparent link. The origin of highly encephalized whales, dolphins and porpoises occurred with the drop in ocean temperatures 25-30 mya. Of course, other possible paths to encephalization are conceivable, with radically different solutions to the problem of heat dissipation. But the intrinsic requirements for information processing capacity necessary for intelligence suggest our terrestrial pattern may resemble those of alien biospheres given similar histories.

  9. Performance of Air-cooled Engine Cylinders Using Blower Cooling

    Science.gov (United States)

    Schey, Oscar W; Ellerbrock, Herman H , Jr

    1936-01-01

    An investigation was made to obtain information on the minimum quantity of air and power required to cool conventional air cooled cylinders at various operating conditions when using a blower. The results of these tests show that the minimum power required for satisfactory cooling with an overall blower efficiency of 100 percent varied from 2 to 6 percent of the engine power depending on the operating conditions. The shape of the jacket had a large effect on the cylinder temperatures. Increasing the air speed over the front of the cylinder by keeping the greater part of the circumference of the cylinder covered by the jacket reduced the temperatures over the entire cylinder.

  10. performance evaluation of a composite-padded evaporative cooling ...

    African Journals Online (AJOL)

    user

    4DEPARTMENT OF MECHANICAL ENGINEERING, UNIVERSITY OF NIGERIA NSUKKA, ENUGU STATE. ... agriculture, especially in places with poor or no electric power supply. ... principle of evaporative cooling. ... their study on application of evaporative cooler to .... International Journal of Emerging Technology and ...

  11. Retrofitting the Southeast: The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

    2013-02-01

    The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  12. Cooling atomic motion with quantum interference

    CERN Document Server

    Morigi, G

    2002-01-01

    We theoretically investigate the quantum dynamics of the center of mass of trapped atoms, whose internal degrees of freedom are driven in a $\\Lambda$-shaped configuration with the lasers tuned at two-photon resonance. In the Lamb-Dicke regime, when the motional wave packet is well localized over the laser wavelenght, transient coherent population trapping occurs, cancelling transitions at the laser frequency. In this limit the motion can be efficiently cooled to the ground state of the trapping potential. We derive an equation for the center-of-mass motion by adiabatically eliminating the internal degrees of freedom. This treatment provides the theoretical background of the scheme presented in [G. Morigi {\\it et al}, Phys. Rev. Lett. {\\bf 85}, 4458 (2000)] and implemented in [C.F. Roos {\\it et al}, Phys. Rev. Lett. {\\bf 85}, 5547 (2000)]. We discuss the physical mechanisms determining the dynamics and identify new parameters regimes, where cooling is efficient. We discuss implementations of the scheme to case...

  13. Cooling arrangement for a tapered turbine blade

    Science.gov (United States)

    Liang, George

    2010-07-27

    A cooling arrangement (11) for a highly tapered gas turbine blade (10). The cooling arrangement (11) includes a pair of parallel triple-pass serpentine cooling circuits (80,82) formed in an inner radial portion (50) of the blade, and a respective pair of single radial channel cooling circuits (84,86) formed in an outer radial portion (52) of the blade (10), with each single radial channel receiving the cooling fluid discharged from a respective one of the triple-pass serpentine cooling circuit. The cooling arrangement advantageously provides a higher degree of cooling to the most highly stressed radially inner portion of the blade, while providing a lower degree of cooling to the less highly stressed radially outer portion of the blade. The cooling arrangement can be implemented with known casting techniques, thereby facilitating its use on highly tapered, highly twisted Row 4 industrial gas turbine blades that could not be cooled with prior art cooling arrangements.

  14. New Approaches to Final Cooling

    CERN Document Server

    Neuffer, David

    2015-01-01

    A high-energy muon collider scenario requires a "final cooling" system that reduces transverse emittance by a factor of ~10 while allowing longitudinal emittance increase. The baseline approach has low-energy transverse cooling within high-field solenoids, with strong longitudinal heating. This approach and its recent simulation are discussed. Alternative approaches which more explicitly include emittance exchange are also presented. Round-to-flat beam transform, transverse slicing, and longitudinal bunch coalescence are possible components of the alternative approach. A more explicit understanding of solenoidal cooling beam dynamics is introduced.

  15. Cooling towers principles and practice

    CERN Document Server

    Hill, G B; Osborn, Peter D

    1990-01-01

    Cooling Towers: Principles and Practice, Third Edition, aims to provide the reader with a better understanding of the theory and practice, so that installations are correctly designed and operated. As with all branches of engineering, new technology calls for a level of technical knowledge which becomes progressively higher; this new edition seeks to ensure that the principles and practice of cooling towers are set against a background of up-to-date technology. The book is organized into three sections. Section A on cooling tower practice covers topics such as the design and operation of c

  16. CLIC inner detectors cooling simulations

    CERN Document Server

    Duarte Ramos, F.; Villarejo Bermudez, M.

    2014-01-01

    The strict requirements in terms of material budget for the inner region of the CLIC detector concepts require the use of a dry gas for the cooling of the respective sen- sors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system that is able to fulfil the required detec- tor specifications. This note introduces a detector cooling strategy using dry air as a coolant and shows the results of computational fluid dynamics simulations used to validate the proposed strategy.

  17. Passive low energy cooling of buildings

    CERN Document Server

    Givoni, Baruch

    1994-01-01

    A practical sourcebook for building designers, providing comprehensive discussion of the impact of basic architectural choices on cooling efficiency, including the layout and orientation of the structure, window size and shading, exterior color, and even the use of plantings around the site. All major varieties of passive cooling systems are presented, with extensive analysis of performance in different types of buildings and in different climates: ventilation; radiant cooling; evaporative cooling; soil cooling; and cooling of outdoor spaces.

  18. Compressor bleed cooling fluid feed system

    Science.gov (United States)

    Donahoo, Eric E; Ross, Christopher W

    2014-11-25

    A compressor bleed cooling fluid feed system for a turbine engine for directing cooling fluids from a compressor to a turbine airfoil cooling system to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The compressor bleed cooling fluid feed system may enable cooling fluids to be exhausted from a compressor exhaust plenum through a downstream compressor bleed collection chamber and into the turbine airfoil cooling system. As such, the suction created in the compressor exhaust plenum mitigates boundary layer growth along the inner surface while providing flow of cooling fluids to the turbine airfoils.

  19. Cooling Technology for Electronic Computers

    Science.gov (United States)

    Nakayama, Wataru

    The rapid growth of data processing speed in computers has been sustained by the advances in cooling technology. This article first presents a review of the published data of heat loads in recent Japanese large-scale computers. The survey indicates that, since around 1980, the high-level integration of microelectronic circuits has brought about almost four fold increase in the power dissipation from logic chips. The integration also has invited the evolutions of multichip modules and new schemes of electronic interconnections. Forced convection air-cooling and liquid cooling coupled with thermal connectors are discussed with reference to the designs employed in actual computers. More advanced cooling schemes are also discussed. Finally, the importance of thermal environmental control of computer rooms is emphasized.

  20. Cooled Ceramic Turbine Vane Project

    Data.gov (United States)

    National Aeronautics and Space Administration — N&R Engineering will investigate the feasibility of cooled ceramics, such as ceramic matrix composite (CMC) turbine blade concepts that can decrease specific...

  1. Surface-induced evaporative cooling

    Institute of Scientific and Technical Information of China (English)

    Ke Min; Yan Bo; Cheng Feng; Wang Yu-Zhu

    2009-01-01

    The effects of surface-induced evaporative cooling on an atom chip are investigated. The evolutions of temperature, number and phase-space density of the atom cloud are measured when the atom cloud is brought close to the surface. Rapid decrease of the temperature and number of the atoms is found when the atom-surface distance is < 100 μm. A gain of about a factor of five on the phase-space density is obtained. It is found that the efficiency of the surface-induced evaporative cooling depends on the atom-surface distance and the shape of the evaporative trap. When the atoms are moved very close to the surface, severe heating is observed, which dominates when the holding time is > 8 ms. It is important that the surface-induced evaporative cooling offers novel possibilities for the realization of a continuous condensation, where a spatially varying evaporative cooling is required.

  2. Method for characterization of a spherically bent crystal for K.alpha. X-ray imaging of laser plasmas using a focusing monochromator geometry

    Science.gov (United States)

    Kugland, Nathan; Doeppner, Tilo; Glenzer, Siegfried; Constantin, Carmen; Niemann, Chris; Neumayer, Paul

    2015-04-07

    A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.

  3. DETERMINATION OF RADIATOR COOLING SURFACE

    Directory of Open Access Journals (Sweden)

    A. I. Yakubovich

    2009-01-01

    Full Text Available The paper proposes a methodology for calculation of a radiator cooling surface with due account of heat transfer non-uniformity on depth of its core. Calculation of radiator cooling surfaces of «Belarus-1221» and «Belarus-3022» tractors has been carried out in the paper. The paper also advances standard size series of radiators for powerful «Belarus» tractor type.

  4. Quantum limit of photothermal cooling

    CERN Document Server

    De Liberato, Simone; Nori, Franco

    2010-01-01

    We study the problem of cooling a mechanical oscillator using the photothermal (bolometric) force. Contrary to previous attempts to model this system, we take into account the noise effects due to the granular nature of photon absorption. This allows us to tackle the cooling problem down to the noise dominated regime and to find reasonable estimates for the lowest achievable phonon occupation in the cantilever.

  5. Cooling Shelf For Electronic Equipment

    Science.gov (United States)

    Tanzer, Herbert J.

    1989-01-01

    Heat-pipe action cools and maintains electronics at nearly constant temperature. System designed to control temperatures of spacecraft shelves or baseplates by combining honeycomb sandwich panel with reservoir of noncondensable gas and processing resulting device as variable-conductance heat pipe. Device provides flat surface for mounting heat-dissipating electronics that is effectively cooled and maintained at nearly constant temperature. Potentially useful in freeze drying, refrigeration, and air conditioning.

  6. Energy Efficient Electronics Cooling Project

    Energy Technology Data Exchange (ETDEWEB)

    Steve O' Shaughnessey; Tim Louvar; Mike Trumbower; Jessica Hunnicutt; Neil Myers

    2012-02-17

    Parker Precision Cooling Business Unit was awarded a Department of Energy grant (DE-EE0000412) to support the DOE-ITP goal of reducing industrial energy intensity and GHG emissions. The project proposed by Precision Cooling was to accelerate the development of a cooling technology for high heat generating electronics components. These components are specifically related to power electronics found in power drives focused on the inverter, converter and transformer modules. The proposed cooling system was expected to simultaneously remove heat from all three of the major modules listed above, while remaining dielectric under all operating conditions. Development of the cooling system to meet specific customer's requirements and constraints not only required a robust system design, but also new components to support long system functionality. Components requiring further development and testing during this project included pumps, fluid couplings, cold plates and condensers. All four of these major categories of components are required in every Precision Cooling system. Not only was design a key area of focus, but the process for manufacturing these components had to be determined and proven through the system development.

  7. Cryogenic cooling system for HTS cable

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru [Taiyo Nippon Sanso, Tsukuba (Japan)

    2017-06-15

    Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

  8. Floor cooling and air-cooling, the effects on thermal comfort or different cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Sijpheer, N.C.; Bakker, E.J.; Ligthart, F.A.T.M.; Opstelten, I.J. [ECN Energie in de Gebouwde Omgeving en Netten, Petten (Netherlands)

    2007-09-15

    One of the research areas of the Energy research Centre of the Netherlands (ECN) concerns the built environment. Several facilities to conduct research activities are at ECN's disposal. One of these facilities, are five research dwellings located on the premises of ECN. Measured data from these facilities together with weather data and computer models are used to evaluate innovative energy concepts and components in energy systems. Experiments with different cooling systems in ECN's research dwellings are executed to evaluate their effective influence on both energy use and thermal comfort. Influence of inhabitants' behaviour is taken into account in these experiments. The thermal comfort is indicated by the Predicted Mean Vote (PMV) as defined by P.O. Fanger. For this paper, the results of measurements with a floor cooling and air cooling system are assessed. Effects on the PMV measured during experiments with the two different cooling systems will be presented.

  9. Design Evaluation Using Finite Element Analysis of Cooled Silicon Nitride Plates for a Turbine Blade Application

    Science.gov (United States)

    Abdul-Aziz, Ali; Baaklini, George Y.; Bhatt, Ramakrishna T.

    2001-01-01

    Two- and three-dimensional finite element analyses were performed on uncoated and thermal barrier coated (TBC) silicon nitride plates with and without internal cooling by air. Steady-state heat-transfer analyses were done to optimize the size and the geometry of the cooling channels to reduce thermal stresses, and to evaluate the thermal environment experienced by the plate during burner rig testing. The limited experimental data available were used to model the thermal profile exerted by the flame on the plate. Thermal stress analyses were performed to assess the stress response due to thermal loading. Contours for the temperature and the representative stresses for the plates were generated and presented for different cooling hole sizes and shapes. Analysis indicates that the TBC experienced higher stresses, and the temperature gradient was much reduced when the plate was internally cooled by air. The advantages and disadvantages of several cooling channel layouts were evaluated.

  10. International Cryocooler Conference

    CERN Document Server

    Cryocoolers 13

    2005-01-01

    This is the 13th volume in the conference series. Over the years the International Cryocoolers Conference has become the preeminent worldwide conference for the presentation of the latest developments and test experiences with cryocoolers. The typical applications of this technology include cooling space and terrestrial infrared focal plane arrays, space x-ray detectors, medical applications, and a growing number of high-temperature super-capacitor applications.

  11. Bunched Beam Cooling in the Fermilab Recycler

    CERN Document Server

    Neuffer, David V; Burov, Alexey; Nagaitsev, Sergei

    2005-01-01

    Stochastic cooling with bunched beam in a linear bucket has been obtained and implemented operationally in the fermilab recycler. In this implementation the particle bunch length is much greater than the cooling system wavelengths. The simultaneous longitudinal bunching enables cooling to much smaller longitudinal emittances than the coasting beam or barrier bucket system. Characteristics and limitations of bunched beam stochastic cooling are discussed.

  12. A new Newton's law of cooling?

    Science.gov (United States)

    Kleiber, M

    1972-12-22

    Several physiologists confuse Fourier's law of animal heat flow with Newton's law of cooling. A critique of this error in 1932 remained ineffective. In 1969 Molnar tested Newton's cooling law. In 1971 Strunk found Newtonian cooling unrealistic for animals. Unfortunately, he called the Fourier formulation of animal heat flow, requiring post-Newtonian observations, a "contemporary Newtonian law of cooling."

  13. 14 CFR 25.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 25.1043 Section 25.1043... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Cooling § 25.1043 Cooling tests. (a) General. Compliance... during the cooling tests must be the minimum grade approved for the engines, and the mixture...

  14. 14 CFR 27.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 27.1043 Section 27.1043... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Cooling § 27.1043 Cooling tests. (a) General. For the tests... during the cooling tests must be of the minimum grade approved for the engines, and the mixture...

  15. 14 CFR 29.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 29.1043 Section 29.1043... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Cooling § 29.1043 Cooling tests. (a) General. For the... (a)(1) of this section may exceed established limits. (3) The fuel used during the cooling tests...

  16. 14 CFR 29.908 - Cooling fans.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling fans. 29.908 Section 29.908... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant General § 29.908 Cooling fans. For cooling fans that are a part of a powerplant installation the following apply: (a) Category A. For cooling fans...

  17. 14 CFR 23.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 23.1043 Section 23.1043... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Cooling § 23.1043 Cooling... established limits. (3) The fuel used during the cooling tests must be of the minimum grade approved for...

  18. Impingement jet cooling in gas turbines

    CERN Document Server

    Amano, R S

    2014-01-01

    Due to the requirement for enhanced cooling technologies on modern gas turbine engines, advanced research and development has had to take place in field of thermal engineering. Impingement jet cooling is one of the most effective in terms of cooling, manufacturability and cost. This is the first to book to focus on impingement cooling alone.

  19. New cooling regulation technology of secondary cooling station in DCS

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xuan; Yan, Jun-wei; Zhu, Dong-sheng; Liu, Fei-long; Lei, Jun-xi [The Key Lab of Enhanced Heat Transfer and Energy Conservation of Ministry of Education, School of Chemical and Energy Engineering, South China University of Technology, Guangzhou 510641 (China); Liang, Lie-quan [The Key Lab of E-Commerce Market Application Technology of Guangdong Province, Guangdong University of Business Studies, Guangzhou 510320 (China)

    2008-07-01

    In this paper, a kind of new control technology of secondary cooling station (constant flow rate/variable temperature difference) in district cooling system (DCS) is proposed in view of serial consequences including low efficiency and high operating cost caused by low temperature of supply water in DCS. This technology has been applied in DCS of Guangzhou University City. The result has already indicated that such technology can increase the supply and return temperatures of buildings, return water temperature of primary side in the plate heat exchanger unit, moreover, the efficiency of both the chiller and the whole system are improved significantly. (author)

  20. Cooling Efficiency of Laminar Cooling System for Plate Mill

    Institute of Scientific and Technical Information of China (English)

    ZHANG Dian-hua; WANG Bing-xing; ZHOU Na; YU Ming; WANG Jun

    2008-01-01

    Heat transfer was researched from a perspective of the industry application.On the basis of the first law of thermodynamics,the cooling efficiency was deduced from the change of enthalpy inside hot plate.The relationship between the cooling efficiency and its influencing parameters was regressed from plenty of data collected from the worksite and discussed in detail.The temperature profiles resulting from the online model and the model modified by regressed formulas were presented and compared.The results indicated that the control accuracy of the modified model was increased obviously.

  1. Personal cooling apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Siman-Tov, Moshe (Knoxville, TN); Crabtree, Jerry Allen (Knoxville, TN)

    2001-01-01

    A portable lightweight cooling apparatus for cooling a human body is disclosed, having a channeled sheet which absorbs sweat and/or evaporative liquid, a layer of highly conductive fibers adjacent the channeled sheet; and, an air-moving device for moving air through the channeled sheet, wherein the layer of fibers redistributes heat uniformly across the object being cooled, while the air moving within the channeled sheet evaporates sweat and/or other evaporative liquid, absorbs evaporated moisture and the uniformly distributed heat generated by the human body, and discharges them into the environment. Also disclosed is a method for removing heat generated by the human body, comprising the steps of providing a garment to be placed in thermal communication with the body; placing a layer of highly conductive fibers within the garment adjacent the body for uniformly distributing the heat generated by the body; attaching an air-moving device in communication with the garment for forcing air into the garment; removably positioning an exchangeable heat sink in communication with the air-moving device for cooling the air prior to the air entering the garment; and, equipping the garment with a channeled sheet in communication with the air-moving device so that air can be directed into the channeled sheet and adjacent the layer of fibers to expell heat and moisture from the body by the air being directed out of the channeled sheet and into the environment. The cooling system may be configured to operate in both sealed and unsealed garments.

  2. Oxygen Absorption in Cooling Flows.

    Science.gov (United States)

    Buote

    2000-04-01

    The inhomogeneous cooling flow scenario predicts the existence of large quantities of gas in massive elliptical galaxies, groups, and clusters that have cooled and dropped out of the flow. Using spatially resolved, deprojected X-ray spectra from the ROSAT PSPC, we have detected strong absorption over energies approximately 0.4-0.8 keV intrinsic to the central approximately 1&arcmin; of the galaxy NGC 1399, the group NGC 5044, and the cluster A1795. These systems have among the largest nearby cooling flows in their respective classes and low Galactic columns. Since no excess absorption is indicated for energies below approximately 0.4 keV, the most reasonable model for the absorber is warm, collisionally ionized gas with T=105-106 K in which ionized states of oxygen provide most of the absorption. Attributing the absorption only to ionized gas reconciles the large columns of cold H and He inferred from Einstein and ASCA with the lack of such columns inferred from ROSAT and also is consistent with the negligible atomic and molecular H inferred from H i and CO observations of cooling flows. The prediction of warm ionized gas as the product of mass dropout in these and other cooling flows can be verified by Chandra and X-Ray Multimirror Mission.

  3. Axion Cooling of Neutron Stars

    CERN Document Server

    Sedrakian, Armen

    2015-01-01

    Cooling simulations of neutron stars and their comparison with the data from thermally emitting X-ray sources puts constraints on the properties of axions, and by extension of any light pseudo-scalar dark matter particles, whose existence has been postulated to solve the strong-CP problem of QCD. We incorporate the axion emission by pair-breaking and formation processes by $S$- and $P$-wave nucleonic condensates in a benchmark code for cooling simulations as well as provide fit formulae for the rates of these processes. Axion cooling of neutron stars has been simulated for 24 models covering the mass range 1 to 1.8 solar masses, featuring non-accreted iron and accreted light element envelopes, and a range of nucleon-axion coupling. The models are based on an equation state predicting conservative physics of superdense nuclear matter that does not allow for onset of fast cooling processes induced by phase transitions to non-nucleonic forms of matter or high proton concentration. The cooling tracks in the tempe...

  4. LCG Persistency Framework (POOL, CORAL, COOL) - Status and Outlook

    CERN Document Server

    CERN. Geneva

    2012-01-01

    The LCG Persistency Framework consists of three software packages (POOL, CORAL and COOL) that address the data access requirements of the LHC experiments in several different areas. The project is the result of the collaboration between the CERN IT Department and the three experiments (ATLAS, CMS and LHCb) that are using some or all of the Persistency Framework components to access their data. The POOL package is a hybrid technology store for C++ objects, using a mixture of streaming and relational technologies to implement both object persistency and object metadata catalogs and collections. POOL provides generic components that can be used by the experiments to store both their event data and their conditions data. The CORAL package is an abstraction layer with an SQL-free API for accessing data stored using relational database technologies. It is used directly by experiment-specific applications and internally by both COOL and POOL. The COOL package provides specific software components and tools for the h...

  5. Design Concepts for Cooled Ceramic Matrix Composite Turbine Vanes

    Science.gov (United States)

    Boyle, Robert

    2014-01-01

    This project demonstrated that higher temperature capabilities of ceramic matrix composites (CMCs) can be used to reduce emissions and improve fuel consumption in gas turbine engines. The work involved closely coupling aerothermal and structural analyses for the first-stage vane of a high-pressure turbine (HPT). These vanes are actively cooled, typically using film cooling. Ceramic materials have structural and thermal properties different from conventional metals used for the first-stage HPT vane. This project identified vane configurations that satisfy CMC structural strength and life constraints while maintaining vane aerodynamic efficiency and reducing vane cooling to improve engine performance and reduce emissions. The project examined modifications to vane internal configurations to achieve the desired objectives. Thermal and pressure stresses are equally important, and both were analyzed using an ANSYS® structural analysis. Three-dimensional fluid and heat transfer analyses were used to determine vane aerodynamic performance and heat load distributions.

  6. Heating and cooling of magnetars with accreted envelopes

    CERN Document Server

    Kaminker, A D; Yakovlev, D G; Chabrier, G

    2009-01-01

    We study the thermal structure and evolution of magnetars as cooling neutron stars with a phenomenological heat source in an internal layer. We focus on the effect of magnetized (B > 10^{14} G) non-accreted and accreted outermost envelopes composed of different elements, from iron to hydrogen or helium. We discuss a combined effect of thermal conduction and neutrino emission in the outer neutron star crust and calculate the cooling of magnetars with a dipole magnetic field for various locations of the heat layer, heat rates and magnetic field strengths. Combined effects of strong magnetic fields and light-element composition simplify the interpretation of magnetars in our model: these effects allow one to interpret observations assuming less extreme (therefore, more realistic) heating. Massive magnetars, with fast neutrino cooling in their cores, can have higher thermal surface luminosity.

  7. Evaluation of Cooling Solutions for Outdoor Electronics

    CERN Document Server

    Wankhede, Mahendra; Goswami, A; Mahajan, S D

    2008-01-01

    The thermal management of an outdoor electronic enclosure can be quite challenging due to the additional thermal load from the sun and the requirement of having an air-sealed enclosure. It is essential to consider the effect of solar heating loads in the design process; otherwise, it can shorten the life expectancy of the electronic product or lead to catastrophic failure. In this paper we analyze and compare the effectiveness of different cooling techniques used for outdoor electronics. Various cooling techniques were compared like special coatings and paints on the outer surface, radiation shields, double-walled vented enclosures, fans for internal air circulation and air-to-air heat exchangers. A highly simplified, typical outdoor system was selected for this study measuring approximately 300x300x400 mm (WxLxH). Solar radiation was incident on 3 sides of the enclosure. There were 8 equally spaced PCBs inside the enclosure dissipating 12.5W each uniformly (100 watts total). A computational fluid dynamics (C...

  8. Investigation of the steam-cooled blade in a steam turbine cascade

    Institute of Scientific and Technical Information of China (English)

    Dieter Bohn; Jing Ren; Karsten Kusterer

    2007-01-01

    With the increasing demand for electricity,an efficiency improvement and thereby reduced CO2 emissions of the coal-fired plants are expected in order to reach the goals set in the Kyoto protocol.It can be achieved by a rise of the process parameters.Currently,live steam pressures and temperatures up to 300 bars and 923 K are planned as the next step.Closed circuit steam cooling of blades and vanes in modern steam turbines is a promising technology in order to establish elevated live steam temperatures in future steam turbine cycles.In this paper,a steam-cooled test vane in a cascade with external hot steam flow is analyzed numerically with the in-house code CHTflow.A parametric analysis aiming to improve the cooling effectiveness is carried out by varying the cooling mass flow ratio.The results from two investigated cases show that the steam cooling technique has a good application potential in the steam turbine.The internal part of the vane is cooled homogeneously in both cases.With the increased cooling mass flow rate,there is a significant improvement of cooling efficiency at the leading edge.The results show that the increased cooling mass flow ratio can enhance the cooling effectiveness at the leading edge.With respect to trailing edge,there is no observable improvement of cooling effectiveness with the increased cooling mass flow.This implies that due to the limited dimension at the trailing edge,the thermal stress cannot be decreased by increasing the cooling mass flow rate.Therefore,impingement-cooling configuration at the trailing edge might be a solution to overcome the critical thermal stress there.It is also observed that the performance of the cooling effective differs on pressure side and suction side.It implicates that the equilibrium of the cooling effectiveness on two sides are influenced by a coupled relationship between cooling mass flow ratio and hole geometry.In future work,optimizing the hole geometry and cooling steam supply conditions might

  9. Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.4). Development of passive cooling mechanism fit for high-temperature high-humidity region; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.4). Koon tashitsu chiiki tekigogata passive reikyaku kiko no kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Efforts are made in cooperation with Vietnam to develop a heat insulating material for buildings, to be used for passive cooling mechanisms symbiotic with the environment and capable of energy conservation. Vegetables are planted on the surface of this building material. Activities are conducted in the three domains of (1) the development of energy conservation-conscious basic materials, (2) selection of vegetables, and (3) the simulation of the effect of the developed materials on temperature. The basic type of the newly developed building material is an asbestos-free vegetable fiber-reinforced cement slate which is covered by such vegetables as members of the Passifloraceae, Vitaceae, and Araliaceae. Conducted in domain (1) are surveys of the actual state of basic material manufacturing in Vietnam and studies of the basic properties of vegetable fiber, properties displayed by vegetable fiber under various chemical environments, selection of vegetable fiber as the basic aggregate, mineral fiber, and the basic material manufacturing conditions. The result of heat load calculation carried out using SMASH for Windows ver.2, which is a program developed for thermal load calculation for houses, shows that the new material lowers the temperature by approximately 3 degrees C. (NEDO)

  10. Optimization of Internal Cooling Fins for Metal Hydride Reactors

    Directory of Open Access Journals (Sweden)

    Vamsi Krishna Kukkapalli

    2016-06-01

    Full Text Available Metal hydride alloys are considered as a promising alternative to conventional hydrogen storage cylinders and mechanical hydrogen compressors. Compared to storing in a classic gas tank, metal hydride alloys can store hydrogen at nearly room pressure and use less volume to store the same amount of hydrogen. However, this hydrogen storage method necessitates an effective way to reject the heat released from the exothermic hydriding reaction. In this paper, a finned conductive insert is adopted to improve the heat transfer in the cylindrical reactor. The fins collect the heat that is volumetrically generated in LaNi5 metal hydride alloys and deliver it to the channel located in the center, through which a refrigerant flows. A multiple-physics modeling is performed to analyze the transient heat and mass transfer during the hydrogen absorption process. Fin design is made to identify the optimum shape of the finned insert for the best heat rejection. For the shape optimization, use of a predefined transient heat generation function is proposed. Simulations show that there exists an optimal length for the fin geometry.

  11. Cool Stars and Space Weather

    CERN Document Server

    Vidotto, A A; Cameron, A C; Morin, J; Villadsen, J; Saar, S; Alvarado, J; Cohen, O; Holzwarth, V; Poppenhaeger, K; Reville, V

    2014-01-01

    Stellar flares, winds and coronal mass ejections form the space weather. They are signatures of the magnetic activity of cool stars and, since activity varies with age, mass and rotation, the space weather that extra-solar planets experience can be very different from the one encountered by the solar system planets. How do stellar activity and magnetism influence the space weather of exoplanets orbiting main-sequence stars? How do the environments surrounding exoplanets differ from those around the planets in our own solar system? How can the detailed knowledge acquired by the solar system community be applied in exoplanetary systems? How does space weather affect habitability? These were questions that were addressed in the splinter session "Cool stars and Space Weather", that took place on 9 Jun 2014, during the Cool Stars 18 meeting. In this paper, we present a summary of the contributions made to this session.

  12. Quench cooling under reduced gravity

    CERN Document Server

    Chatain, D; Nikolayev, V S; Beysens, D

    2013-01-01

    We report the quench cooling experiments performed with liquid O2 under different levels of gravity simulated with the magnetic gravity compensation. A copper disk is quenched from 270K to 90K. It is found that the cooling time in microgravity is very long in comparison with any other gravity level. This phenomenon is explained by the isolation effect of the gas surrounding the disk. The liquid subcooling is shown to drastically improuve the heat exchange thus reducing the cooling time (about 20 times). The effect of subcooling on the heat transfer is analyzed at different gravity levels. It is shown that such type of experiments cannot be used for the analysis of the critical heat flux (CHF) of the boiling crisis. The minimum heat flux (MHF) of boiling is analyzed instead.

  13. Improving Durability of Turbine Components Through Trenched Film Cooling and Contoured Endwalls

    Energy Technology Data Exchange (ETDEWEB)

    Bogard, David G. [Univ. of Texas, Austin, TX (United States); Thole, Karen A. [Pennsylvania State Univ., State College, PA (United States)

    2014-09-30

    The experimental and computational studies of the turbine endwall and vane models completed in this research program have provided a comprehensive understanding of turbine cooling with combined film cooling and TBC. To correctly simulate the cooling effects of TBC requires the use of matched Biot number models, a technique developed in our laboratories. This technique allows for the measurement of the overall cooling effectiveness which is a measure of the combined internal and external cooling for a turbine component. The overall cooling effectiveness provides an indication of the actual metal temperature that would occur at engine conditions, and is hence a more powerful performance indicator than the film effectiveness parameter that is commonly used for film cooling studies. Furthermore these studies include the effects of contaminant depositions which are expected to occur when gas turbines are operated with syngas fuels. Results from the endwall studies performed at Penn State University and the vane model studies performed at the University of Texas are the first direct measurements of the combined effects of film cooling and TBC. These results show that TBC has a dominating effect on the overall cooling effectiveness, which enhances the importance of the internal cooling mechanisms, and downplays the importance of the film cooling of the external surface. The TBC was found to increase overall cooling effectiveness by a factor of two to four. When combined with TBC, the primary cooling from film cooling holes was found to be due to the convective cooling within the holes, not from the film effectiveness on the surface of the TBC. Simulations of the deposition of contaminants on the endwall and vane surfaces showed that these depositions caused a large increase in surface roughness and significant degradation of film effectiveness. However, despite these negative factors, the depositions caused only a slight decrease in the overall cooling effectiveness on

  14. The effect of pre-cooling intensity on cooling efficiency and exercise performance

    NARCIS (Netherlands)

    Bogerd, N.; Perret, C.; Bogerd, C.P.; Rossi, R.M.; Daanen, H.A.M.

    2010-01-01

    Although pre-cooling is known to enhance exercise performance, the optimal cooling intensity is unknown. We hypothesized that mild cooling opposed to strong cooling circumvents skin vasoconstriction and thermogenesis, and thus improves cooling efficiency reflected in improved time to exhaustion. Eig

  15. Retrofitting the Southeast. The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W. [Steven Winter Associates, Inc., Norwalk, CT (United States); Shapiro, C. [Steven Winter Associates, Inc., Norwalk, CT (United States); Vijayakumar, G. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-02-01

    The Consortium for Advanced Residential Buildings research team has provided the technical engineering and building science support for a highly visible demonstration home that was unveiled at the National Association of Home Builders' International Builders Show on Feb. 9, 2012, in Orlando, FL. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This report describes the deep energy retrofit of the Cool Energy House (CEH), which began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  16. Cooling and Heating Solid Quark Stars

    CERN Document Server

    Yu, Meng

    2009-01-01

    We present here a phenomenological solid quark star pulsar model to interpret the observed thermal X-ray emission of isolated pulsars. The heat capacity for solid quark stars was found to be quite small, so that the residual internal stellar heat gained at the birth of the star could be dissipated in an extremely short timescale. However, the bombardment induced by backflowing plasma at the poles of solid quark stars would get the stars be reheated, so that long term soft X-ray emission can be sustained. Such a scenario could be used for those X-ray pulsars with significant magnetospheric activities, and their cooling processes would thus be established. Dim X-ray isolated neutron stars (XDINs) as well as compact central objects (CCOs) have been observed with dominant soft X-ray radiation combined with little magnetospheric manifestations. Such sources could be solid quark stars accreting in the propeller regime.

  17. New Approaches to Final Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, David [Fermilab

    2014-11-10

    A high-energy muon collider scenario require a “final cooling” system that reduces transverse emittances by a factor of ~10 while allowing longitudinal emittance increase. The baseline approach has low-energy transverse cooling within high-field solenoids, with strong longitudinal heating. This approach and its recent simulation are discussed. Alternative approaches which more explicitly include emittance exchange are also presented. Round-to-flat beam transform, transverse slicing, and longitudinal bunch coalescence are possible components of the alternative approach. A more explicit understanding of solenoidal cooling beam dynamics is introduced.

  18. Beam Dynamics With Electron Cooling

    CERN Document Server

    Uesugi, T; Noda, K; Shibuya, S; Syresin, E M

    2004-01-01

    Electron cooling experiments have been carried out at HIMAC in order to develop new technologies in heavy-ion therapy and related researches. The cool-stacking method, in particular, has been studied to increase the intensity of heavy-ions. The maximum stack intensity was 2 mA, above which a fast ion losses occurred simulatneously with the vertical coherent oscillations. The instability depends on the working point, the stacked ion-density and the electron-beam density. The instability was suppressed by reducing the peak ion-density with RF-knockout heating.

  19. On-chip magnetic cooling of a nanoelectronic device

    Science.gov (United States)

    Bradley, D. I.; Guénault, A. M.; Gunnarsson, D.; Haley, R. P.; Holt, S.; Jones, A. T.; Pashkin, Yu. A.; Penttilä, J.; Prance, J. R.; Prunnila, M.; Roschier, L.

    2017-04-01

    We demonstrate significant cooling of electrons in a nanostructure below 10 mK by demagnetisation of thin-film copper on a silicon chip. Our approach overcomes the typical bottleneck of weak electron-phonon scattering by coupling the electrons directly to a bath of refrigerated nuclei, rather than cooling via phonons in the host lattice. Consequently, weak electron-phonon scattering becomes an advant- age. It allows the electrons to be cooled for an experimentally useful period of time to temperatures colder than the dilution refrigerator platform, the incoming electrical connections, and the host lattice. There are efforts worldwide to reach sub-millikelvin electron temperatures in nanostructures to study coherent electronic phenomena and improve the operation of nanoelectronic devices. On-chip magnetic cooling is a promising approach to meet this challenge. The method can be used to reach low, local electron temperatures in other nanostructures, obviating the need to adapt traditional, large demagnetisation stages. We demonstrate the technique by applying it to a nanoelectronic primary thermometer that measures its internal electron temperature. Using an optimised demagnetisation process, we demonstrate cooling of the on-chip electrons from 9 mK to below 5 mK for over 1000 seconds.

  20. Beyond Newton's law of cooling - estimation of time since death

    Science.gov (United States)

    Leinbach, Carl

    2011-09-01

    The estimate of the time since death and, thus, the time of death is strictly that, an estimate. However, the time of death can be an important piece of information in some coroner's cases, especially those that involve criminal or insurance investigations. It has been known almost from the beginning of time that bodies cool after the internal mechanisms such as circulation of the blood stop. A first attempt to link this phenomenon to the determination of the time of death used a crude linear relationship. Towards the end of the nineteenth century, Newton's law of cooling using body temperature data obtained by the coroner was used to make a more accurate estimate. While based on scientific principles and resulting in a better estimate, Newton's law does not really describe the cooling of a non-homogeneous human body. This article will discuss a more accurate model of the cooling process based on the theoretical work of Marshall and Hoare and the laboratory-based statistical work of Claus Henssge. Using DERIVE®6.10 and the statistical work of Henssge, the double exponential cooling formula developed by Marshall and Hoare will be explored. The end result is a tool that can be used in the field by coroner's scene investigators to determine a 95% confidence interval for the time since death and, thus, the time of death.

  1. Influence of intranasal and carotid cooling on cerebral temperature balance and oxygenation

    Directory of Open Access Journals (Sweden)

    Lars eNybo

    2014-02-01

    Full Text Available The present study evaluated the influence of intranasal cooling with balloon catheters, increased nasal ventilation, or percutaneous cooling of the carotid arteries on cerebral temperature balance and oxygenation in six healthy male subjects. Aortic arch and internal jugular venous blood temperatures were measured to assess the cerebral heat balance and corresponding paired blood samples were obtained to evaluate cerebral metabolism and oxygenation at rest, following 60 min of intranasal cooling, 5 min of nasal ventilation, and 15 min with carotid cooling. Intranasal cooling induced a parallel drop in jugular venous and arterial blood temperatures by 0.30 ± 0.08 ºC (mean ± SD, whereas nasal ventilation and carotid cooling failed to lower the jugular venous blood temperature. The magnitude of the arterio-venous temperature difference across the brain remained unchanged at - 0.33 ± 0.05 ºC following intranasal and carotid cooling, but increased to - 0.44 ± 0.11 ºC (P< 0.05 following nasal ventilation. Calculated cerebral capillary oxygen tension was 43 ± 3 mmHg at rest and remained unchanged during intranasal and carotid cooling, but decreased to 38 ± 2 mmHg (P< 0.05 following increased nasal ventilation. In conclusion, percutaneous cooling of the carotid arteries and intranasal cooling with balloon catheters are insufficient to influence cerebral oxygenation in normothermic subjects as the cooling rate is only 0.3 ºC per hour and neither intranasal nor carotid cooling is capable of inducing selective brain cooling.

  2. Increased output of blown film extrusion lines by using a cooling sleeve

    Science.gov (United States)

    Hopmann, Christian; Windeck, Christian; Hennigs, Marco

    2014-05-01

    Production efficiency is one of the most important demands in blown film production. In many cases, the cooling power is the limiting factor for an increased output. A possible solution for a better cooling is the use of a cooling sleeve right after the outlet of the die in addition to the conventional air rings and internal bubble cooling (IBC). At the Institute of Plastics Processing (IKV), first tests were conducted to investigate the advantages of the use of a cooling sleeve. Therefore, the influence of several geometries of the cooling sleeve surface and different cooling sleeve temperatures on the process stability and the mechanical and optical film properties is investigated. The cooling sleeve surfaces differ in the tapping between inlet and outlet diameter from 0 % (cylindric) to 10 % (conical). The tests show that a high amount of tapping as well as too high resp. low cooling sleeve temperatures cause process instabilities and an uneven thickness profile of the film. While the mechanical film properties (E-modulus, elongation at break, tensile strength) of the films produced by the use of a cooling sleeve (cs-films) do not significantly differ from the values of the reference films, the haze of the cs-films was higher and therefore worse. A measurement of the bubble temperatures above the air ring shows that the use of a cooling sleeve can significant lower the bubble temperature at this point. Because of this and because of the results of the mechanical tests, the principle of a contact cooling is generally applicable. Further research and development on the geometry of the cooling sleeve surface has to be done to improve the process stability and the haze for a possible industrial application.

  3. GOTHIC Simulation of Passive Containment Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Huiun; Kim, Hangon [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2013-05-15

    The performance of this system depends on the condensation of steam moving downward inside externally cooled vertical tubes. AES-2006: During a DBA, heat is removed by internally cooled vertical tubes, which are located in containment. We are currently developing the conceptual design of Innovative PWR, which is will be equipped with various passive safety features, including PCCS. We have plan to use internal heat exchanger (HX) type PCCS with concrete containment. In this case, the elevation of HXs is important to ensure the heat removal during accidents. In general, steam is lighter than air mixture in containment. So, steam may be collected at the upper side of containment. It means that higher elevation of HXs, larger heat removal efficiency of those. So, the aim of the present paper is to give preliminary study on variation of heat removal performance according to elevation of HXs. With reference to the design specification of the current reactors including APR+, we had determined conceptual design of PCCS. Using it, we developed a GOTHIC model of the APR1400 containment was adopted PCCS. This calculation model is described herein and representative results of calculation are presented. APR 1400 GOTHIC model was developed for PCCS performance calculation and sensitivity test according to installation elevation of PCCXs. Calculation results confirm that PCCS is working properly. It is found that the difference due to the installation elevation of PCCXs is insignificant at this preliminary analysis, however, further studies should be performed to confirm final performance of PCCS according to the installation elevation. These insights are important for developing the PCCS of Innovative PWR.

  4. Electromechanically cooled germanium radiation detector system

    Science.gov (United States)

    Lavietes, Anthony D.; Joseph Mauger, G.; Anderson, Eric H.

    1999-02-01

    We have successfully developed and fielded an electromechanically cooled germanium radiation detector (EMC-HPGe) at Lawrence Livermore National Laboratory (LLNL). This detector system was designed to provide optimum energy resolution, long lifetime, and extremely reliable operation for unattended and portable applications. For most analytical applications, high purity germanium (HPGe) detectors are the standard detectors of choice, providing an unsurpassed combination of high energy resolution performance and exceptional detection efficiency. Logistical difficulties associated with providing the required liquid nitrogen (LN) for cooling is the primary reason that these systems are found mainly in laboratories. The EMC-HPGe detector system described in this paper successfully provides HPGe detector performance in a portable instrument that allows for isotopic analysis in the field. It incorporates a unique active vibration control system that allows the use of a Sunpower Stirling cycle cryocooler unit without significant spectral degradation from microphonics. All standard isotopic analysis codes, including MGA and MGA++ [1], GAMANL [2], GRPANL [3]and MGAU [4], typically used with HPGe detectors can be used with this system with excellent results. Several national and international Safeguards organisations including the International Atomic Energy Agency (IAEA) and U.S. Department of Energy (DOE) have expressed interest in this system. The detector was combined with custom software and demonstrated as a rapid Field Radiometric Identification System (FRIS) for the U.S. Customs Service [5]. The European Communities' Safeguards Directorate (EURATOM) is field-testing the first Safeguards prototype in their applications. The EMC-HPGe detector system design, recent applications, and results will be highlighted.

  5. A comparative study on showerhead cooling performance

    Energy Technology Data Exchange (ETDEWEB)

    Falcoz, C.; Ott, P. [Ecole Polytechnique Federale de Lausanne (EPFL), Laboratoire de Thermique Appliquee et de Turbomachines (LTT), 1015 Lausanne (Switzerland); Weigand, B. [Institut fuer Thermodynamik der Luft- und Raumfahrt (ITLR), Stuttgart University, Pfaffenwaldring 31, 70569 Stuttgart (Germany)

    2006-04-15

    In modern gas turbines, the turbine airfoil leading edge is currently protected from the hot gas by specific film cooling schemes, so called showerhead cooling. The present paper shows a numerical study of different showerhead cooling geometries. The 3D finite element program ABAQUS as well as a 2D finite element program have been employed to predict the showerhead cooling performance. In the numerical calculations, the different cooling effects and their contribution to the total showerhead cooling performance have been investigated separately. From the numerical calculations a simple method has been derived which enables the prediction of the performance of a 3D showerhead cooling scheme by simple 2D computations. Experimental investigations on showerhead cooling have been presented in a companion paper [C. Falcoz, B. Weigand, P. Ott, Experimental investigations on showerhead cooling on a blunt body. Int. J. Heat Mass Transfer, in press. r publication]. (author)

  6. The Proposed Heating and Cooling System in the CH2 Building and Its Impact on Occupant Productivity

    Directory of Open Access Journals (Sweden)

    Lu Aye

    2012-11-01

    Full Text Available Melbourne's climatic conditions demand that its buildings require both heating and cooling systems. In a multi-storey office building , however, cooling requirements will dominate. How the internal space is cooled and ventilation air is delivered will significantly impact on occupant comfort. This paper discusses the heating and cooling systems proposed for the CH2building. The paper critiques the proposed systems against previous experience, both internationally and in Australia. While the heating system employs proven technologies, less established techniques are proposed for the cooling system. Air movement in the shower towers, for example, is to be naturally induced and this has not always been successful elsewhere. Phase change material for storage of "coolth" does not appear to have been demonstrated previously in a commercial building, so the effectiveness of the proposed system is uncertain. A conventional absorption chiller backs up the untried elements of the cooling system, so that ultimately occupant comfort should not be compromised .

  7. Ionization Cooling for Muon Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Alexahin, Y. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Neuffer, D. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Prebys, E. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2014-09-18

    Possible application for muon experiments such as mu2e is discussed of the initial part of the ionization cooling channel originally developed for muon collider. It is shown that with the FNAL Booster as the proton driver the mu2e sensitivity can be increased by two orders of magnitude compared to the presently considered experiment.

  8. Ionization Cooling for Muon Experiments

    OpenAIRE

    Alexahin, Y.; D. Neuffer; Prebys, E.

    2014-01-01

    Possible application for muon experiments such as mu2e is discussed of the initial part of the ionization cooling channel originally developed for muon collider. It is shown that with the FNAL Booster as the proton driver the mu2e sensitivity can be increased by two orders of magnitude compared to the presently considered experiment.

  9. Inductive cooling in quantum magnetomechanics

    Science.gov (United States)

    Romero-Sanchez, Erick; Twamley, Jason; Bowen, Warwick P.; Vanner, Michael R.

    Coupling to light or microwave fields allows quantum control of the motion of a mechanical oscillator, and offers prospects for precision sensing, quantum information systems, and tests of fundamental physics. In cavity electromechanics ground state cooling has been achieved using resolved sideband cooling. Here we present an alternative approach based on a magnetomechanical system that inductively couples an LC resonator to a mechanical oscillator. The experimental setup consists of a micro cantilever with a pyramidal magnetic tip attached at the end of the beam. The sharp end of the magnetic tip is positioned close to the planar microfabricated inductor of the LC resonator. The displacement in the position of the end of the cantilever generates a change in flux through the coil inducing an electromotive force in the circuit. The current in the LC resonator generates a magnetic field, and then a force between the tip and the coil. When they are strongly coupled and the mechanical resonance frequency ωm exceeds the electrical decay rate of the resonator γe, resolved sideband cooling can be used to cool the mechanics. We present estimations for the coupling rates and the experimental parameters required for these experiments. E. Romero acknowledges to CONACyT.

  10. Cool Runnings For String 2

    CERN Multimedia

    2001-01-01

    String 2 is a series of superconducting magnets that are prototypes of those which will be installed in the LHC. It was cooled down to 1.9 Kelvin on September 14th. On Thursday last week, the dipoles of String 2 were successfully taken to nominal current, 11850 A.

  11. System for cooling a cabinet

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a cooling system comprising an active magnetic regenerator having a cold side and a hot side, a hot side heat exchanger connected to the hot side of the magnetic regenerator, one or more cold side heat exchangers, and a cold store reservoir comprising a volume...

  12. Garment Would Provide Variable Cooling

    Science.gov (United States)

    Buckley, Theresa M.

    1991-01-01

    Conceptual protective garment includes tubes containing pumped cooling slurry. Overall coefficient for transfer of heat from wearer to slurry depends on tube-to-skin, through-the-wall-of-the-tube, and tube-to-slurry coefficients. Concept applicable to suits worn when cleaning up spilled chemicals or fighting fires.

  13. Passive Cooling of Body Armor

    Science.gov (United States)

    Holtz, Ronald; Matic, Peter; Mott, David

    2013-03-01

    Warfighter performance can be adversely affected by heat load and weight of equipment. Current tactical vest designs are good insulators and lack ventilation, thus do not provide effective management of metabolic heat generated. NRL has undertaken a systematic study of tactical vest thermal management, leading to physics-based strategies that provide improved cooling without undesirable consequences such as added weight, added electrical power requirements, or compromised protection. The approach is based on evaporative cooling of sweat produced by the wearer of the vest, in an air flow provided by ambient wind or ambulatory motion of the wearer. Using an approach including thermodynamic analysis, computational fluid dynamics modeling, air flow measurements of model ventilated vest architectures, and studies of the influence of fabric aerodynamic drag characteristics, materials and geometry were identified that optimize passive cooling of tactical vests. Specific architectural features of the vest design allow for optimal ventilation patterns, and selection of fabrics for vest construction optimize evaporation rates while reducing air flow resistance. Cooling rates consistent with the theoretical and modeling predictions were verified experimentally for 3D mockups.

  14. Solar-powered cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, Joseph C

    2013-12-24

    A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.

  15. A cool present for LEIR

    CERN Multimedia

    2005-01-01

    LEIR (Low Energy Ion Ring), which will supply lead ions to the LHC experiments, has taken delivery of one of its key components, its electron cooling system. From left to right, Gérard Tranquille, Virginia Prieto and Roland Sautier, in charge of the electron cooling system for LEIR at CERN, and Christian Lacroix, in charge of installation for the LEIR machine. On 16 December, the day before CERN's annual closure, the LEIR teams received a rather impressive Christmas present. The "parcel" from Russia, measuring 7 metres in length and 4 metres in height, weighed no less than 20 tonnes! The component will, in fact, be one of the key elements of the future LEIR, namely its electron cooling system. LEIR is one of the links in the injector chain that will supply lead ions to the LHC experiments, in particular ALICE (see Bulletin No. 28/2004 of 5 July 2004), within the framework of the I-LHC Project. The electron cooling system is designed to reduce and standardise transverse ion velocity. This focuses the bea...

  16. Second law evaluation of a lightweight cooling unit

    Directory of Open Access Journals (Sweden)

    Guilherme B. Ribeiro

    2016-03-01

    Full Text Available The analysis based on the second law of thermodynamics of a lightweight vapor compression refrigeration system is presented. A small-scale linear compressor was applied in a DC-powered portable cooler for vehicles and for the medical field, using finned-tube heat exchangers and R600-a (Isobutane as the working fluid. The cooler was tested in an environmental chamber (with controlled temperature and humidity under three different ambient temperatures (21, 25 and 32 °C in order to measure key parameters of the system, such as cooling capacity, power consumption and internal air temperature. For the comparison of thermodynamic irreversibilities, a conventional vapor compression refrigerating system was also tested under the same ambient conditions. Results indicated that the system with the proposed lightweight system kept the lowest internal air temperature with higher coefficients of performance, showing how a lightweight cooling unit can enlarge the use of refrigerating systems due to its attributes.

  17. Evaluation Tool of Climate Potential for Ventilative Cooling

    DEFF Research Database (Denmark)

    Belleri, Annamaria; Psomas, Theofanis Ch.; Heiselberg, Per Kvols

    2015-01-01

    designers with useful information about the level of ventilation rates needed to offset given rates of internal heat gain. The paper also presents several analysis performed on a reference room in a case study (Aarhus town hall office in Denmark) in order to validate the analysis method development......The new initiatives and regulations towards nearly zero energy buildings forces designers to exploit the cooling potential of the climate to reduce the overheating occurrence and to improve thermal comfort indoors. Climate analysis is particularly useful at early design stages to support decision....... Within IEA Annex 62 project, national experts are working on the development of a climate evaluation tool, which aims at assessing the potential of ventilative cooling by taking into account also building envelope thermal properties, internal gains and ventilation needs. The analysis is based on a single...

  18. An Experimental Investigation on Transpiration Cooling Part II: Comparison of Cooling Methods and Media

    OpenAIRE

    Wang J; Messner J.; Stetter H.

    2004-01-01

    This article attempts to provide a cooling performance comparison of various mass transfer cooling methods and different cooling media through two experiments. In the first experiment, pressurized air was used as a cooling medium and two different circular tubes were used as specimens. One is made of impermeable solid material with four rows of discrete holes to simulate film cooling, and the other consists of sintered porous material to create a porous transpiration cooling effect. The...

  19. Gas turbine heat transfer and cooling technology

    CERN Document Server

    Han, Je-Chin; Ekkad, Srinath

    2012-01-01

    FundamentalsNeed for Turbine Blade CoolingTurbine-Cooling TechnologyTurbine Heat Transfer and Cooling IssuesStructure of the BookReview Articles and Book Chapters on Turbine Cooling and Heat TransferNew Information from 2000 to 2010ReferencesTurbine Heat TransferIntroductionTurbine-Stage Heat TransferCascade Vane Heat-Transfer ExperimentsCascade Blade Heat TransferAirfoil Endwall Heat TransferTurbine Rotor Blade Tip Heat TransferLeading-Edge Region Heat TransferFlat-Surface Heat TransferNew Information from 2000 to 20102.10 ClosureReferencesTurbine Film CoolingIntroductionFilm Cooling on Rotat

  20. Multi-pass cooling for turbine airfoils

    Science.gov (United States)

    Liang, George

    2011-06-28

    An airfoil for a turbine vane of a gas turbine engine. The airfoil includes an outer wall having pressure and suction sides, and a radially extending cooling cavity located between the pressure and suction sides. A plurality of partitions extend radially through the cooling cavity to define a plurality of interconnected cooling channels located at successive chordal locations through the cooling cavity. The cooling channels define a serpentine flow path extending in the chordal direction. Further, the cooling channels include a plurality of interconnected chambers and the chambers define a serpentine path extending in the radial direction within the serpentine path extending in the chordal direction.