WorldWideScience

Sample records for monitoring system included

  1. Specifications and design criteria for innovative corrosion monitoring and (downhole) sensor systems, including sensitivity analysis

    NARCIS (Netherlands)

    Zhang, X.; Kermen. E.

    2013-01-01

    This report focuses on the corrosion monitoring and corrosion sensor systems, for use in CO2 storage wells, including a sensitivity analysis. The feasibility for using new sensors to measure well integrity based on electrochemical principles is investigated. The use of corrosion sensors in CO2 stora

  2. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  3. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  4. Monitoring Regional Forest Disturbances across the US with Near Real Time MODIS NDVI Products included in the ForWarn Forest Threat Early Warning System

    Science.gov (United States)

    Spruce, Joseph; Hargrove, William W.; Gasser, Gerald; Norman, Steve

    2013-01-01

    U.S. forests occupy approx.1/3 of total land area (approx. 304 million ha). Since 2000, a growing number of regionally evident forest disturbances have occurred due to abiotic and biotic agents. Regional forest disturbances can threaten human life and property, bio-diversity and water supplies. Timely regional forest disturbance monitoring products are needed to aid forest health management work. Near Real Time (NRT) twice daily MODIS NDVI data provide a means to monitor U.S. regional forest disturbances every 8 days. Since 2010, these NRT forest change products have been produced and posted on the US Forest Service ForWarn Early Warning System for Forest Threats.

  5. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  6. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  7. Flight Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I project will develop the Flight System Monitor which will use non-intrusive electrical monitoring (NEMO). The electronic system health of...

  8. OpenSM Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    2015-04-17

    The OpenSM Monitoring System includes a collection of diagnostic and monitoring tools for use on Infiniband networks. The information this system gathers is obtained from a service, which in turn is obtained directly from the OpenSM subnet manager.

  9. CERN Safety System Monitoring - SSM

    CERN Document Server

    Hakulinen, T; Valentini, F; Gonzalez, J; Salatko-Petryszcze, C

    2011-01-01

    CERN SSM (Safety System Monitoring) [1] is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs, servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix [2], on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from handheld devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems.

  10. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  11. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  12. Earth System Monitoring, Introduction

    Science.gov (United States)

    Orcutt, John

    This section provides sensing and data collection methodologies, as well as an understanding of Earth's climate parameters and natural and man-made phenomena, to support a scientific assessment of the Earth system as a whole, and its response to natural and human-induced changes. The coverage ranges from climate change factors and extreme weather and fires to oil spill tracking and volcanic eruptions. This serves as a basis to enable improved prediction and response to climate change, weather, and natural hazards as well as dissemination of the data and conclusions. The data collection systems include satellite remote sensing, aerial surveys, and land- and ocean-based monitoring stations. Our objective in this treatise is to provide a significant portion of the scientific and engineering basis of Earth system monitoring and to provide this in 17 detailed articles or chapters written at a level for use by university students through practicing professionals. The reader is also directed to the closely related sections on Ecological Systems, Introduction and also Climate Change Modeling Methodology, Introduction as well as Climate Change Remediation, Introduction to. For ease of use by students, each article begins with a glossary of terms, while at an average length of 25 print pages each, sufficient detail is presented for use by professionals in government, universities, and industries. The chapters are individually summarized below.

  13. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  14. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I STTR project will demonstrate the Aerospace System Monitor (ASM). This technology transforms the power distribution network in a spacecraft or aircraft...

  15. Engineering monitoring expert system's developer

    Science.gov (United States)

    Lo, Ching F.

    1991-01-01

    This research project is designed to apply artificial intelligence technology including expert systems, dynamic interface of neural networks, and hypertext to construct an expert system developer. The developer environment is specifically suited to building expert systems which monitor the performance of ground support equipment for propulsion systems and testing facilities. The expert system developer, through the use of a graphics interface and a rule network, will be transparent to the user during rule constructing and data scanning of the knowledge base. The project will result in a software system that allows its user to build specific monitoring type expert systems which monitor various equipments used for propulsion systems or ground testing facilities and accrues system performance information in a dynamic knowledge base.

  16. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  17. Analysis of polymer molecules including reaction monitoring and control

    NARCIS (Netherlands)

    Schoenmakers, P.; van Herk, A.M.

    2013-01-01

    To monitor, control, and optimize emulsion polymerisations, there is a need to perform a variety of different measurements. The monomer conversion is a key parameter to monitor and control the reaction. A rapid response is required for real-time reaction monitoring. This chapter considers on-line an

  18. Nekton Interaction Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-15

    The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonar devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).

  19. Wearable Health Monitoring Systems

    Science.gov (United States)

    Bell, John

    2015-01-01

    The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

  20. Vehicle chassis monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pisu, P.; Soliman, A.; Rizzoni, G. [Ohio State Univ., Columbus (United States). Center for Automotive Research

    2001-07-01

    Fault detection and isolation is becoming one of the most important aspects in vehicle control system design. In order to achieve this FDI schemes, particular vehicle subsystems integrated with a controller have been proposed. This paper introduces a new model-based fault detection and fault diagnosis method for monitoring the vehicle chassis performance. (orig.)

  1. Inductive System Monitors Tasks

    Science.gov (United States)

    2008-01-01

    The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of

  2. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  3. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  4. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  5. Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor)

    2017-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to control communication of data, via the bus, with each of the plurality of data acquisition modules.

  6. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  7. Article Including Environmental Barrier Coating System

    Science.gov (United States)

    Lee, Kang N. (Inventor)

    2015-01-01

    An enhanced environmental barrier coating for a silicon containing substrate. The enhanced barrier coating may include a bond coat doped with at least one of an alkali metal oxide and an alkali earth metal oxide. The enhanced barrier coating may include a composite mullite bond coat including BSAS and another distinct second phase oxide applied over said surface.

  8. Tools for Distributed Systems Monitoring

    Directory of Open Access Journals (Sweden)

    Kufel Łukasz

    2016-11-01

    Full Text Available The management of distributed systems infrastructure requires dedicated set of tools. The one tool that helps visualize current operational state of all systems and notify when failure occurs is available within monitoring solution. This paper provides an overview of monitoring approaches for gathering data from distributed systems and what are the major factors to consider when choosing a monitoring solution. Finally we discuss the tools currently available on the market.

  9. Design and Development of Patient Monitoring System

    Science.gov (United States)

    Hazwanie Azizulkarim, Azra; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    Patient monitoring system allows continuous monitoring of patient vital signs, support decision making among medical personnel and help enhance patient care. This system can consist of devices that measure, display and record human’s vital signs, including body temperature, heart rate, blood pressure and other health-related criteria. This paper proposes a system to monitor the patient’s conditions by monitoring the body temperature and pulse rate. The system consists of a pulse rate monitoring software and a wearable device that can measure a subject’s temperature and pulse rate only by using a fingertip. The device is able to record the measurement data and interface to PC via Arduino microcontroller. The recorded data can be viewed as a historical file or can be archived for further analysis. This work also describes the preliminary experimental results of the selected sensors to show the usefulness of the sensors for the proposed patient monitoring system.

  10. Coastwide Reference Monitoring System (CRMS)

    Science.gov (United States)

    2010-01-01

    In 1990, the U.S. Congress enacted the Coastal Wetlands Planning, Protection and Restoration Act (CWPPRA) in response to growing awareness of a land loss crisis in Louisiana. Projects funded by CWPPRA require monitoring and evaluation of project effectiveness, and there is also a need to assess the cumulative effects of all projects to achieve a sustainable coastal environment. In 2003, the Louisiana Office of Coastal Protection and Restoration (OCPR) and the U.S. Geological Survey (USGS) received approval from the CWPPRA Task Force to implement the Coastwide Reference Monitoring System (CRMS) as a mechanism to monitor and evaluate the effectiveness of CWPPRA projects at the project, region, and coastwide levels. The CRMS design implements a multiple reference approach by using aspects of hydrogeomorphic functional assessments and probabilistic sampling. The CRMS program is as dynamic as the coastal habitats it monitors. The program is currently funded through CWPPRA and provides data for a variety of user groups, including resource managers, academics, landowners, and researchers.

  11. Intelligent monitoring system for intensive care units.

    Science.gov (United States)

    Nouira, Kaouther; Trabelsi, Abdelwahed

    2012-08-01

    We address in the present paper a medical monitoring system designed as a multi-agent based approach. Our system includes mainly numerous agents that act as correlated multi-agent sub-systems at the three layers of the whole monitoring infrastructure, to avoid non informative alarms and send effective alarms at time. The intelligence in the proposed monitoring system is provided by the use of time series technology. In fact, the capability of continuous learning of time series from the physiological variables allows the design of a system that monitors patients in real-time. Such system is a contrast to the classical threshold-based monitoring system actually present in the Intensive Care Units (ICUs) which causes a huge number of irrelevant alarms.

  12. Storage monitoring systems for the year 2000

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C.; Pollock, R.

    1997-12-31

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000.

  13. Electrochemical system including lamella settler crystallizer

    Science.gov (United States)

    Maimoni, Arturo

    1988-01-01

    A crystallizer which incorporates a lamella settler and which is particularly applicable for use in batteries and power cells for electric vehicles or stationary applications. The lamella settler can be utilized for coarse particle separation or for agglomeration, and is particularly applicable to aluminum-air batteries or power cells for solving the hydrargillite (aluminum-hydroxide) removal problems from such batteries. This invention provides the advantages of very low energy consumption, turbulence, shear, cost and maintenance. Thus, due to the low shear and low turbulence of this invention, it is particularly effective in the control of aluminum hydroxide particle size distribution in the various sections of an aluminum-air system, as will as in other elecrochemical systems requiring separation for phases of different densities.

  14. Designing monitoring programs for chemicals of emerging concern in potable reuse ⋯ What to include and what not to include?

    KAUST Repository

    Drewes, Jorg

    2012-11-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than \\'1\\' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound. © IWA Publishing 2013.

  15. Monitoring Systems for Hydropower Plants

    Directory of Open Access Journals (Sweden)

    Damaschin Pepa

    2015-07-01

    Full Text Available One of the most important issue in hydro power industry is to determine the necessary degree of automation in order to improve the operation security. Depending upon the complexity of the system (the power plant equipment the automation specialist will build a philosophy of control following some general principals of security and operation. Helped by the modern digital equipment, today is relative easy to design a complete monitoring and supervising system including all the subparts of a hydro aggregate. A series of sensors and transducers specific for each auxiliary installation of the turbine and generator will be provided, together with a PLC or an industrial PC that will run an application software for implementing the security and control algorithms. The purpose of this paper is to offer a general view of these issues, providing a view of designing an automation & control and security system for hydro power plants of small, medium and big power.

  16. Ecological Monitoring Information System (EMIS).

    Science.gov (United States)

    Fiene, Richard John; And Others

    A system for evaluating and monitoring child development projects, with possible computerization capabilities, was developed for the State of Pennsylvania in connection with 26 child development projects funded by the Appalachian Regional Commission. The Ecological Monitoring Information System (EMIS), provides a series of ecological measurement…

  17. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  18. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  19. Automatic respiration monitoring system; Shushin jotai no jido monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This is a system to recognize automatically status of a person in sleep including respiration stop, toss about in bed, and departure from the bed by performing animated image processing on images of the person in sleep as photographed by a camera, and by obtaining respiration waveforms from changes in the images of the breast. The system has been developed jointly by the Medical Department of Ehime University and Toshiba Engineering Company when commissioned from the Silver Service Promotion Association as a two-year project. The system requires no operation by an operator, can monitor the respiration during sleep on a real time basis from a completely non-restraint condition, and can be utilized for early discovery of crib death and/or apneic syndrome of aged persons and infants. Its effectiveness was verified by the field tests at a special facility for physically and mentally handicapped aged persons. The system was awarded with the first grand prize for an image recognition system from the Japan Automatic Recognition System Association. (translated by NEDO)

  20. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  1. Unattended Monitoring System Design Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-07-08

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations.

  2. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  3. Monitored Geologic Repository Operations Monitoring and Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    E.F. Loros

    2000-06-29

    The Monitored Geologic Repository Operations Monitoring and Control System provides supervisory control, monitoring, and selected remote control of primary and secondary repository operations. Primary repository operations consist of both surface and subsurface activities relating to high-level waste receipt, preparation, and emplacement. Secondary repository operations consist of support operations for waste handling and treatment, utilities, subsurface construction, and other selected ancillary activities. Remote control of the subsurface emplacement operations, as well as, repository performance confirmation operations are the direct responsibility of the system. In addition, the system monitors parameters such as radiological data, air quality data, fire detection status, meteorological conditions, unauthorized access, and abnormal operating conditions, to ensure a safe workplace for personnel. Parameters are displayed in a real-time manner to human operators regarding surface and subsurface conditions. The system performs supervisory monitoring and control for both important to safety and non-safety systems. The system provides repository operational information, alarm capability, and human operator response messages during emergency response situations. The system also includes logic control to place equipment, systems, and utilities in a safe operational mode or complete shutdown during emergency response situations. The system initiates alarms and provides operational data to enable appropriate actions at the local level in support of emergency response, radiological protection response, evacuation, and underground rescue. The system provides data communications, data processing, managerial reports, data storage, and data analysis. This system's primary surface and subsurface operator consoles, for both supervisory and remote control activities, will be located in a Central Control Center (CCC) inside one of the surface facility buildings. The system

  4. Study on communication and management system including status monitoring of NC machine based on DNC%利用DNC的数控通信管理及状态监测系统的研究

    Institute of Scientific and Technical Information of China (English)

    王荣; 陈进

    2012-01-01

    An integrated DNC system was designed by using multithreading, DNC networking,network communication and data acquisition technology. The system achieves NC program two-way transmission and remote call between DNC server and CNC machines. It monitors and collects the information about processing status of machines,and figure out their utilization. The system also manages many kinds of information about NC machine and production.%综合利用多线程、DNC联网技术、网络通信技术和数据采集技术设计了一种集成DNC系统,实现DNC服务器与数控机床之间NC程序的双向传输和远程调用,对机床的加工状态进行实时监测采集,统计机床的利用率,对各类数控信息和生产信息进行妥善管理.

  5. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  6. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  7. 75 FR 64411 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Science.gov (United States)

    2010-10-19

    ... the CMDPSU or CPDM and the sampled work shift is less than 8 hours, the value of t used for... Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors; Proposed Rule #0;#0;Federal Register... to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors AGENCY: Mine Safety and...

  8. Wearable Health Monitoring Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  9. Wearable Health Monitoring Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  10. Solar Power Systems Web Monitoring

    CERN Document Server

    Kumar, Bimal Aklesh

    2011-01-01

    All over the world the peak demand load is increasing and the load factor is decreasing year-by-year. The fossil fuel is considered insufficient thus solar energy systems are becoming more and more useful, not only in terms of installation but monitoring of these systems is very crucial. Monitoring becomes very important when there are a large number of solar panels. Monitoring would allow early detection if the output falls below required level or one of the solar panel out of 1000 goes down. In this study the target is to monitor and control a developed solar panel by using available internet foundation. This web-enabled software will provide more flexibility over the system such as transmitting data from panel to the host computer and disseminating information to relevant stake holders barring any geographical barrier. The software would be built around web server with dynamic HTML and JAVA, this paper presents the preliminary design of the proposed system.

  11. 76 FR 6826 - Certain Display Devices Including Digital Televisions and Monitors; Notice of Commission...

    Science.gov (United States)

    2011-02-08

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Display Devices Including Digital Televisions and Monitors; Notice of Commission... within the United States after importation of certain digital display devices including digital...

  12. Electric drive systems including smoothing capacitor cooling devices and systems

    Energy Technology Data Exchange (ETDEWEB)

    Dede, Ercan Mehmet; Zhou, Feng

    2017-02-28

    An electric drive system includes a smoothing capacitor including at least one terminal, a bus bar electrically coupled to the at least one terminal, a thermoelectric device including a first side and a second side positioned opposite the first side, where the first side is thermally coupled to at least one of the at least one terminal and the bus bar, and a cooling element thermally coupled to the second side of the thermoelectric device, where the cooling element dissipates heat from the thermoelectric device.

  13. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2006-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  14. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2007-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  15. A grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin; /Fermilab; Nowack, Andreas; /Aachen, Tech. Hochsch.; Padhi, Sanjay; /UC, San Diego; Sarkar, Subir; /INFN, Pisa /Pisa, Scuola Normale Superiore

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  16. NOAA Atmospheric, Marine and Arctic Monitoring Using UASs (including Rapid Response)

    Science.gov (United States)

    Coffey, J. J.; Jacobs, T.

    2015-12-01

    Unmanned systems have the potential to efficiently, effectively, economically, and safely bridge critical observation requirements in an environmentally friendly manner. As the United States' Atmospheric, Marine and Arctic areas of interest expand and include hard-to-reach regions of the Earth (such as the Arctic and remote oceanic areas) optimizing unmanned capabilities will be needed to advance the United States' science, technology and security efforts. Through increased multi-mission and multi-agency operations using improved inter-operable and autonomous unmanned systems, the research and operations communities will better collect environmental intelligence and better protect our Country against hazardous weather, environmental, marine and polar hazards. This presentation will examine NOAA's Atmospheric, Marine and Arctic Monitoring Unmanned Aircraft System (UAS) strategies which includes developing a coordinated effort to maximize the efficiency and capabilities of unmanned systems across the federal government and research partners. Numerous intra- and inter-agency operational demonstrations and assessments have been made to verify and validated these strategies. This includes the introduction of the Targeted Autonomous Insitu Sensing and Rapid Response (TAISRR) with UAS concept of operations. The presentation will also discuss the requisite UAS capabilities and our experience in using them.

  17. Operational Linescan System (OLS) - Derived Products (including posters and slides)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Visible and infrared imagery from DMSP Operational Linescan System (OLS) instruments are used to monitor the global distribution of clouds and cloud top temperatures...

  18. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  19. Interim performance criteria for photovoltaic energy systems. [Glossary included

    Energy Technology Data Exchange (ETDEWEB)

    DeBlasio, R.; Forman, S.; Hogan, S.; Nuss, G.; Post, H.; Ross, R.; Schafft, H.

    1980-12-01

    This document is a response to the Photovoltaic Research, Development, and Demonstration Act of 1978 (P.L. 95-590) which required the generation of performance criteria for photovoltaic energy systems. Since the document is evolutionary and will be updated, the term interim is used. More than 50 experts in the photovoltaic field have contributed in the writing and review of the 179 performance criteria listed in this document. The performance criteria address characteristics of present-day photovoltaic systems that are of interest to manufacturers, government agencies, purchasers, and all others interested in various aspects of photovoltaic system performance and safety. The performance criteria apply to the system as a whole and to its possible subsystems: array, power conditioning, monitor and control, storage, cabling, and power distribution. They are further categorized according to the following performance attributes: electrical, thermal, mechanical/structural, safety, durability/reliability, installation/operation/maintenance, and building/site. Each criterion contains a statement of expected performance (nonprescriptive), a method of evaluation, and a commentary with further information or justification. Over 50 references for background information are also given. A glossary with definitions relevant to photovoltaic systems and a section on test methods are presented in the appendices. Twenty test methods are included to measure performance characteristics of the subsystem elements. These test methods and other parts of the document will be expanded or revised as future experience and needs dictate.

  20. System Reliability Analysis of Redundant Condition Monitoring Systems

    Institute of Scientific and Technical Information of China (English)

    YI Pengxing; HU Youming; YANG Shuzi; WU Bo; CUI Feng

    2006-01-01

    The development and application of new reliability models and methods are presented to analyze the system reliability of complex condition monitoring systems. The methods include a method analyzing failure modes of a type of redundant condition monitoring systems (RCMS) by invoking failure tree model, Markov modeling techniques for analyzing system reliability of RCMS, and methods for estimating Markov model parameters. Furthermore, a computing case is investigated and many conclusions upon this case are summarized. Results show that the method proposed here is practical and valuable for designing condition monitoring systems and their maintenance.

  1. BES Monitoring & Displaying System

    Institute of Scientific and Technical Information of China (English)

    MengWANG; BingyunZHANG; 等

    2001-01-01

    BES1 Monitoring & Displaying System(BESMDS)is projected to monitor and display the running status of DAQ and Slow Control systems of BES through the Web for worldwide accessing.It provides a real-time remote means of monitoring as well as an approach to study the environmental influence upon physical data taking.The system collects real-time data separately from BES online subsystems by network sockets and stores the data into a database.People can access the system through its web site.which retrieves data on request from the database and can display results in dynamically created images.Its web address in http:// besmds,ihep.ac.cn/

  2. A Research on Distributed Emergency Monitoring System

    Institute of Scientific and Technical Information of China (English)

    WANG; Kai; LI; Hang; YANG; Hong-wei; LIU; Yang; ZHANG; Liang; CHEN; Ling; XIONG; Wen-jun

    2013-01-01

    1 Introduction The distributed emergency monitoring system(DEMS),which has distributed measurement,centralized information processing features,including integrated radiation detectors,wireless transmission evaluation and presentation software module.The system uses a GM counter and NaI(Tl)spectrometer to quickly get the information of the radiation field,and transmits the information to the on-site information

  3. 77 FR 3793 - Certain Liquid Crystal Display Devices, Including Monitors, Televisions, and Modules, and...

    Science.gov (United States)

    2012-01-25

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Liquid Crystal Display Devices, Including Monitors, Televisions, and Modules, and Components Thereof; Request for Statements on the Public Interest AGENCY: U.S. International Trade Commission...

  4. 77 FR 45375 - Certain Liquid Crystal Display Devices, Including Monitors, Televisions, Modules, and Components...

    Science.gov (United States)

    2012-07-31

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Liquid Crystal Display Devices, Including Monitors, Televisions, Modules, and Components Thereof; Commission Determination Not To Review an Initial Determination Terminating the Investigation as...

  5. Research and Construction the Net Monitor System

    OpenAIRE

    Ruining Huang; Lei Li; Yunjiang Lou

    2012-01-01

    A Net Monitor system is presented in this paper. The system is based on STMicroelectronics board FLTK3D, which provides hardware platform for TV functions--3D film, IPTV, 3D game, cable television and so on. The whole system includes the Linux Operating System (OS), embedded web browser, Media player, clouding applications, video conference and 3D game. It utilizes the reference model of the CLFS (Cross Linux From Scratches) principle to construct the embedded Linux OS. Cloud applications are...

  6. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-01-28

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. The redesign and upgrade of the laboratory prototype was completed on schedule and it was assembled during the last period. Testing was begin during the first week of October. Initial results indicated that the dynamic range of the damping was less than predicted and that the maximum damping was also less than required. A number of possible explanations for these results were posited, and test equipment was acquired to evaluate the various hypotheses. Testing was just underway at the end of this period.

  7. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-10-29

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Phase II began on June 1, and the first month's effort were reported in the seventh quarterly report on the project.1 The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. The redesign and upgrade of the laboratory prototype was completed on schedule during this period, and assembly was complete at the end of this period. Testing will begin during the first week of October. This aspect of the project is thus approximately six weeks behind schedule. Design of the field prototype is progressing per schedule.

  8. Monitoring the CMS data acquisition system

    Science.gov (United States)

    Bauer, G.; Behrens, U.; Biery, K.; Branson, J.; Cano, E.; Cheung, H.; Ciganek, M.; Cittolin, S.; Coarasa, J. A.; Deldicque, C.; Dusinberre, E.; Erhan, S.; Fortes Rodrigues, F.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Gutleber, J.; Hatton, D.; Laurens, J. F.; Lopez Perez, J. A.; Meijers, F.; Meschi, E.; Meyer, A.; Mommsen, R.; Moser, R.; O'Dell, V.; Oh, A.; Orsini, L. B.; Patras, V.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Sakulin, H.; Sani, M.; Schieferdecker, P.; Schwick, C.; Shpakov, D.; Simon, S.; Sumorok, K.; Zanetti, M.

    2010-04-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of collections. An implementation following this scheme is deployed as the monitoring infrastructure of the CMS experiment at the Large Hadron Collider. All services in this distributed data acquisition system are providing standard web service interfaces via XML, SOAP and HTTP [15,22]. Continuing on this path we adopted WS-* standards implementing a monitoring system layered on top of the W3C standards stack. We designed a load-balanced publisher/subscriber system with the ability to include high-speed protocols [10,12] for efficient data transmission [11,13,14] and serving data in multiple data formats.

  9. Acoustic Flow Monitor System - User Manual

    Science.gov (United States)

    LaHusen, Richard

    2005-01-01

    INTRODUCTION The Acoustic Flow Monitor (AFM) is a portable system that was designed by the U.S. Geological Survey Cascades Volcano Observatory to detect and monitor debris flows associated with volcanoes. It has been successfully used internationally as part of real-time warning systems in valleys threatened by such flows (Brantley, 1990; Marcial and others, 1996; Lavigne and others, 2000). The AFM system has also been proven to be an effective tool for monitoring some non-volcanic debris flows. This manual is intended to serve as a basic guide for the installation, testing, and maintenance of AFM systems. An overview of how the system works, as well as instructions for installation and guidelines for testing, is included. Interpretation of data is not covered in this manual; rather, the user should refer to the references provided for published examples of AFM data.

  10. Power Transformer Intelligence Monitor System

    Institute of Scientific and Technical Information of China (English)

    Sun Jianshe; Shi Lei

    2006-01-01

    An auto-monitoring system has been created that could monitor the main parameter of power transformers. It reads data of V&I by precision rectifier circuit and amplifier, and converted electric energy into pulse signal by means of sensor technique and pulse converter circuit, it is sent into microcomputer to process, completed monitoring to power transformer parameters and running state by software system. It can register all kinds of key data, and provide all kinds of virtual technical data for managing sections and can auto-form all kinds of electric annual reports and monthly reports analysis graphs such as managing graphs. It notably improves the safety and reliability of transformer, with strong anti-jamming technique and unique function, it can be used on the transformers in railway' s self-closing lines and all kinds of transformer stations.

  11. Phonocardiograph system monitors heart sounds

    Science.gov (United States)

    1966-01-01

    Phonocardiograph system monitors the mechanical activity of the heart in extreme environments. It uses a piezoelectric-crystal microphone with an integral preamplifier, and a signal conditioner having special frequency characteristics. The output signals can be recorded on tape, presented aurally, or transmitted telemetrically to a remote station.

  12. Energy Monitoring System Berbasis Web

    Directory of Open Access Journals (Sweden)

    Novan Zulkarnain

    2013-12-01

    Full Text Available Government through the Ministry of Energy and Mineral Resources (ESDM encourages the energy savings at whole buildings in Indonesia. Energy Monitoring System (EMS is a web-based solution to monitor energy usage in a building. The research methods used are the analysis, prototype design and testing. EMSconsists of hardware which consists of electrical sensors, temperature-humidity sensor, and a computer. Data on EMS are designed using Modbus protocol, stored in MySQL database application, and displayed on charts through Dashboard on LED TV using PHP programming.

  13. Methods, apparatus, and systems for monitoring transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Polk, Robert E; Svoboda, John M.; West, Phillip B.; Heath, Gail L.; Scott, Clark L.

    2016-07-19

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  14. Diabetes Monitoring System Using Mobile Computing Technologies

    Directory of Open Access Journals (Sweden)

    Mashael Saud Bin-Sabbar

    2013-03-01

    Full Text Available Diabetes is a chronic disease that needs to regularly be monitored to keep the blood sugar levels within normal ranges. This monitoring depends on the diabetic treatment plan that is periodically reviewed by the endocrinologist. The frequent visit to the main hospital seems to be tiring and time consuming for both endocrinologist and diabetes patients. The patient may have to travel to the main city, paying a ticket and reserving a place to stay. Those expenses can be reduced by remotely monitoring the diabetes patients with the help of mobile devices. In this paper, we introduce our implementation of an integrated monitoring tool for the diabetes patients. The designed system provides a daily monitoring and monthly services. The daily monitoring includes recording the result of daily analysis and activates to be transmitted from a patient’s mobile device to a central database. The monthly services require the patient to visit a nearby care center in the patient home town to do the medical examination and checkups. The result of this visit entered into the system and then synchronized with the central database. Finally, the endocrinologist can remotely monitor the patient record and adjust the treatment plan and the insulin doses if need.

  15. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-04-27

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. As a result of the lower than expected performance of the MR damper noted last quarter, several additional tests were conducted. These dealt with possible causes of the lack of dynamic range observed in the testing: additional damping from the oil in the Belleville springs; changes in properties of the MR fluid; and, residual magnetization of the valve components. Of these, only the last was found to be significant. By using a laboratory demagnetization apparatus between runs, a dynamic range of 10:1 was achieved for the damper, more than adequate to produce the needed improvements in drilling. Additional modeling was also performed to identify a method of increasing the magnetic field in the damper. As a result of the above, several changes were made in the design. Additional circuitry was added to demagnetize the valve as the field is lowered. The valve was located to above the Belleville springs to reduce the load placed upon it and offer a greater range of materials for its construction. In addition, to further increase the field strength, the coils were relocated from the mandrel to the outer housing. At the end of the quarter, the redesign was complete and new parts were on order. The project is approximately three months behind schedule at this time.

  16. Remote Monitoring System for Communication Base Based on Short Message

    Directory of Open Access Journals (Sweden)

    Han Yu Fu

    2013-07-01

    Full Text Available This paper presents design and development of an automatic monitoring system of communication base which is an important means to realize modernization of mobile communication base station management. Firstly, this paper proposes the architecture of the monitoring system. The proposed system consists of mocrocontrollers, sensors, GSM module and MFRC500 etc. The value of parameters is measured in the system including terminal is studied and designed, including hardware design based on embedded system and software design. Finally, communication module is discussed. The monitoring system which is designed  based on GSM SMS(short message service can improve the integrity, reliability, flexibility and intellectuality of monitoring system.

  17. DOPA, a Digital Observatory for Protected Areas including Monitoring and Forecasting Services

    Science.gov (United States)

    Dubois, Gregoire; Hartley, Andrew; Peedell, Stephen; de Jesus, Jorge; Ó Tuama, Éamonn; Cottam, Andrew; May, Ian; Fisher, Ian; Nativi, Stefano; Bertrand, Francis

    2010-05-01

    The Digital Observatory for Protected Areas (DOPA) is a biodiversity information system currently developed as an interoperable web service at the Joint Research Centre of the European Commission in collaboration with other international organizations, including GBIF, UNEP-WCMC, Birdlife International and RSPB. DOPA is designed to assess the state and pressure of Protected Areas (PAs) and to prioritize them accordingly, in order to support decision making and fund allocation processes. To become an operational web service allowing the automatic monitoring of protected areas, DOPA needs to be able to capture the dynamics of spatio-temporal changes in habitats and anthropogenic pressure on PAs as well as the changes in the species distributions. Because some of the most valuable natural ecosystems and species on the planet cover large areas making field monitoring methods very difficult for a large scale assessment, the automatic collection and processing of remote sensing data are processes at the heart of the problem. To further be able to forecast changes due to climate change, DOPA has to rely on an architecture that enables it to communicate with the appropriate modeling web services. The purpose of this presentation is to present the architecture of the DOPA with special attention to e-Habitat, its web processing service designed for assessing the irreplaceability of habitats as well as for the modeling of habitats under different climate change scenarios. The use of open standards for spatial data and of open source programming languages for the development of the core functionalities of the system are expected to encourage the participation of the scientific community beyond the current partnerships and to favour the sharing of such an observatory which could be installed at any other location. Acknowledgement: Part of this work is funded under the 7th Framework Programme by the EuroGEOSS (www.eurogeoss.eu) project of the European Commission. The views

  18. 29 CFR 1954.2 - Monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System....

  19. Software Oriented Data Monitoring System

    CERN Document Server

    K, Phani Nandan

    2010-01-01

    This project "Software Oriented Data Monitoring System" deals with real time monitoring of patients' parameters like body temperature, heart rate etc. The parameters are checked at regular intervals and Short Messaging Service (SMS) is sent to concerned doctor regarding the measured values. If the obtained parameters are above or below critical values, an alert SMS is also sent to the concerned doctor. This system is very much useful in hospitals, which saves the valuable time of the doctor who otherwise will have to monitor the patients throughout the day. Here the analog data from the sensors is first converted into digital form and is fed to the parallel port of the computer. This data obtained is converted into useful parameters, which is monitored and checked for safe limits. Appropriate SMS is sent to the doctor depending on whether the request is from an alert or routine signal. This is possible by interfacing a mobile phone (Siemens c35i) to the serial port of the computer. The SMS is sent from the co...

  20. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  1. Slow Monitoring Systems for CUORE

    Science.gov (United States)

    Dutta, Suryabrata; Cuore Collaboration

    2016-09-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale neutrinoless double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS). The experiment is comprised of 988 TeO2 bolometric crystals arranged into 19 towers and operated at a temperature of 10 mK. We have developed slow monitoring systems to monitor the cryostat during detector installation, commissioning, data taking, and other crucial phases of the experiment. Our systems use responsive LabVIEW virtual instruments and video streams of the cryostat. We built a website using the Angular, Bootstrap, and MongoDB frameworks to display this data in real-time. The website can also display archival data and send alarms. I will present how we constructed these slow monitoring systems to be robust, accurate, and secure, while maintaining reliable access for the entire collaboration from any platform in order to ensure efficient communications and fast diagnoses of all CUORE systems.

  2. Hypoxia, Monitoring, and Mitigation System

    Science.gov (United States)

    2015-08-01

    When compared to max VO2 as derived from a person’s two-mile run an indication of personalized capacity state can be generated which can also be...Monitoring, Alert and Mitigation System HR Heart Rate HRC Heart Rate Complexity HW Hardware IDR Initial Design Review K Thousand m Meters max Maximum... reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of

  3. 77 FR 37067 - Certain Liquid Crystal Display Devices, Including Monitors, Televisions, Modules, and Components...

    Science.gov (United States)

    2012-06-20

    ... [Federal Register Volume 77, Number 119 (Wednesday, June 20, 2012)] [Notices] [Pages 37067-37068] [FR Doc No: 2012-15005] INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-741/749] Certain Liquid Crystal Display Devices, Including Monitors, Televisions, Modules, and Components Thereof; Final...

  4. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G; Salapura, Valentina

    2014-12-02

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  5. Replaceable Sensor System for Bioreactor Monitoring

    Science.gov (United States)

    Mayo, Mike; Savoy, Steve; Bruno, John

    2006-01-01

    A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

  6. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based quest

  7. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based quest

  8. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  9. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  10. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  11. Inherently safe passive gas monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Cordaro, Joseph V.; Bellamy, John Stephen; Shuler, James M.; Shull, Davis J.; Leduc, Daniel R.

    2016-09-06

    Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.

  12. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  13. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons......A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... will be tested. Laboratory studies as well as on-line measurements in district heating systems using probes in a specially designed sidestream unit are included in the practical part of the project....

  14. Integrated monitoring and surveillance system demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Aumeier, S.E.; Walters, G. [Argonne National Lab., Idaho Falls, ID (United States); Kotter, D.; Walrath, W.M.; Zamecnik, R.J. [Lockheed-Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-07-01

    We present a summary of efforts associated with the installation of an integrated system for the surveillance and monitoring of stabilized plutonium metals and oxides in long-term storage. The product of this effort will include a Pu storage requirements document, baseline integrated monitoring and surveillance system (IMSS) prototype and test bed that will be installed in the Fuel Manufacturing Facility (FMF) nuclear material vault at Argonne National Laboratory - West (ANL-W), and a Pu tracking database including data analysis capabilities. The prototype will be based on a minimal set of vault and package monitoring requirements as derived from applicable DOE documentation and guidelines, detailed in the requirements document, including DOE-STD-3013-96. The use of standardized requirements will aid individual sites in the selection of sensors that best suit their needs while the prototype IMSS, located at ANL-W, will be used as a test bed to compare and contrast sensor performance against a baseline integrated system (the IMSS), demonstrate system capabilities, evaluate potential technology gaps, and test new hardware and software designs using various storage configurations. With efforts currently underway to repackage and store a substantial quantity of plutonium and plutonium-bearing material within the DOE complex, this is an opportune time to undertake such a project. 4 refs.

  15. Intrusion Detection System: Security Monitoring System

    Directory of Open Access Journals (Sweden)

    ShabnamNoorani,

    2015-10-01

    Full Text Available An intrusion detection system (IDS is an ad hoc security solution to protect flawed computer systems. It works like a burglar alarm that goes off if someone tampers with or manages to get past other security mechanisms such as authentication mechanisms and firewalls. An Intrusion Detection System (IDS is a device or a software application that monitors network or system activities for malicious activities or policy violations and produces reports to a management station.Intrusion Detection System (IDS has been used as a vital instrument in defending the network from this malicious or abnormal activity..In this paper we are comparing host based and network based IDS and various types of attacks possible on IDS.

  16. A Resilient Condition Assessment Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Humberto Garcia; Wen-Chiao Lin; Semyon M. Meerkov

    2012-08-01

    An architecture and supporting methods are presented for the implementation of a resilient condition assessment monitoring system that can adaptively accommodate both cyber and physical anomalies to a monitored system under observation. In particular, the architecture includes three layers: information, assessment, and sensor selection. The information layer estimates probability distributions of process variables based on sensor measurements and assessments of the quality of sensor data. Based on these estimates, the assessment layer then employs probabilistic reasoning methods to assess the plant health. The sensor selection layer selects sensors so that assessments of the plant condition can be made within desired time periods. Resilient features of the developed system are then illustrated by simulations of a simplified power plant model, where a large portion of the sensors are under attack.

  17. Productivity Enhancement through Production Monitoring System

    OpenAIRE

    Prasad, Shiva H C; Rao, Potti Srinivasa; Gopalkrishna, B; Ahluwalia, Aakash

    2017-01-01

    A production monitoring system uses the real-time data while production is online. The real-time production monitoring systems are designed as means of auto data to the collection and monitoring the data via display boards. This study focuses on analysing the real-time production monitoring systems through trend analysis in production and over consumption of raw material controlling the over consumptions in a pen manufacturing industry. The methodology followed is through process flow diagram...

  18. Evolutionary Autonomous Health Monitoring System (EAHMS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For supporting NASA's Robotics, Tele-Robotics and Autonomous Systems Roadmap, we are proposing the "Evolutionary Autonomous Health Monitoring System" (EAHMS) for...

  19. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  20. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  1. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  2. Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

    Science.gov (United States)

    Iverson, David L. (Inventor)

    2008-01-01

    The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

  3. Standard hydrogen monitoring system equipment installation instructions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1996-09-27

    This document provides the technical specifications for the equipment fabrication, installation, and sitework construction for the Standard Hydrogen Monitoring System. The Standard Hydrogen Monitoring System is designed to remove gases from waste tank vapor space and exhaust headers for continual monitoring and remote sample analysis.

  4. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-01-09

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program entails modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. The project continues to advance, but is behind the revised (14-month) schedule. Tasks 1-3 (Modeling, Specification and Design) are all essentially complete. The test bench for the Test and Evaluation (Tasks 4 & 5) has been designed and constructed. The design of the full-scale laboratory prototype and associated test equipment is complete and the components are out for manufacture. Barring any unforeseen difficulties, laboratory testing should be complete by the end of March, as currently scheduled. We anticipate the expenses through March to be approximately equal to those budgeted for Phase I.

  5. The ingestible thermal monitoring system

    Science.gov (United States)

    Cutchis, Protagoras N.; Hogrefe, Arthur F.; Lesho, Jeffery C.

    1988-01-01

    A thermal monitoring system for measuring body core temperatures was developed that contains an ingestible pill which is both commandable and rechargeable, and which uses magnetic induction for command and telemetry as well as for recharging. The pill electronics consist of a battery power source, a crystal-controlled oscillator that drives a small air coil, and a command detection circuit. The resulting 262-kHz magnetilc field can be easily detected from a distance of 1 m. The pill oscillator functions at voltages less than 1 V, supplied by a single Ni-Cd battery, which must be recharged after 72 h of continuous transmission. The pill can be recalibrated periodically to compensate for long-term drift.

  6. 48 CFR 1552.239-103 - Acquisition of Energy Star Compliant Microcomputers, Including Personal Computers, Monitors and...

    Science.gov (United States)

    2010-10-01

    ... Compliant Microcomputers, Including Personal Computers, Monitors and Printers. 1552.239-103 Section 1552.239... Star Compliant Microcomputers, Including Personal Computers, Monitors and Printers. As prescribed in... Personal Computers, Monitors, and Printers (APR 1996) (a) The Contractor shall provide computer products...

  7. 75 FR 16817 - 2010 Scientific Meeting of the National Antimicrobial Resistance Monitoring System; Public...

    Science.gov (United States)

    2010-04-02

    ... announcing a public meeting entitled ``2010 Scientific Meeting of the National Antimicrobial Resistance Monitoring System.'' The topic to be discussed is the results from the National Antimicrobial Resistance Monitoring System (NARMS) and related antimicrobial resistance monitoring and research, including activities...

  8. Global integrated drought monitoring and prediction system.

    Science.gov (United States)

    Hao, Zengchao; AghaKouchak, Amir; Nakhjiri, Navid; Farahmand, Alireza

    2014-01-01

    Drought is by far the most costly natural disaster that can lead to widespread impacts, including water and food crises. Here we present data sets available from the Global Integrated Drought Monitoring and Prediction System (GIDMaPS), which provides drought information based on multiple drought indicators. The system provides meteorological and agricultural drought information based on multiple satellite-, and model-based precipitation and soil moisture data sets. GIDMaPS includes a near real-time monitoring component and a seasonal probabilistic prediction module. The data sets include historical drought severity data from the monitoring component, and probabilistic seasonal forecasts from the prediction module. The probabilistic forecasts provide essential information for early warning, taking preventive measures, and planning mitigation strategies. GIDMaPS data sets are a significant extension to current capabilities and data sets for global drought assessment and early warning. The presented data sets would be instrumental in reducing drought impacts especially in developing countries. Our results indicate that GIDMaPS data sets reliably captured several major droughts from across the globe.

  9. Low temperature monitoring system for subsurface barriers

    Science.gov (United States)

    Vinegar, Harold J.; McKinzie, II. Billy John

    2009-08-18

    A system for monitoring temperature of a subsurface low temperature zone is described. The system includes a plurality of freeze wells configured to form the low temperature zone, one or more lasers, and a fiber optic cable coupled to at least one laser. A portion of the fiber optic cable is positioned in at least one freeze well. At least one laser is configured to transmit light pulses into a first end of the fiber optic cable. An analyzer is coupled to the fiber optic cable. The analyzer is configured to receive return signals from the light pulses.

  10. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  11. Valve-"Health"-Monitoring System

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  12. FarMon:An Extensible,Efficient Cluster Monitoring System

    Institute of Scientific and Technical Information of China (English)

    YongFAN; MeiMA; 等

    2001-01-01

    This paper presents the design and implementation of FarMon-a flexible event monitoring system for computing cluster,Using several techniques including DCL (Dynamic Class Loading)technique,module publish/subacribe/unsubscribe protocol and directory service,we create a high efficient,high extensible and high portable cluster monitoring system.

  13. Honey Bee Colonies Remote Monitoring System

    Science.gov (United States)

    Gil-Lebrero, Sergio; Quiles-Latorre, Francisco Javier; Ortiz-López, Manuel; Sánchez-Ruiz, Víctor; Gámiz-López, Victoria; Luna-Rodríguez, Juan Jesús

    2016-01-01

    Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD). The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee) based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time. PMID:28036061

  14. Honey Bee Colonies Remote Monitoring System

    Directory of Open Access Journals (Sweden)

    Sergio Gil-Lebrero

    2016-12-01

    Full Text Available Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD. The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time.

  15. [Portable Epileptic Seizure Monitoring Intelligent System Based on Android System].

    Science.gov (United States)

    Liang, Zhenhu; Wu, Shufeng; Yang, Chunlin; Jiang, Zhenzhou; Yu, Tao; Lu, Chengbiao; Li, Xiaoli

    2016-02-01

    The clinical electroencephalogram (EEG) monitoring systems based on personal computer system can not meet the requirements of portability and home usage. The epilepsy patients have to be monitored in hospital for an extended period of time, which imposes a heavy burden on hospitals. In the present study, we designed a portable 16-lead networked monitoring system based on the Android smart phone. The system uses some technologies including the active electrode, the WiFi wireless transmission, the multi-scale permutation entropy (MPE) algorithm, the back-propagation (BP) neural network algorithm, etc. Moreover, the software of Android mobile application can realize the processing and analysis of EEG data, the display of EEG waveform and the alarm of epileptic seizure. The system has been tested on the mobile phones with Android 2. 3 operating system or higher version and the results showed that this software ran accurately and steadily in the detection of epileptic seizure. In conclusion, this paper provides a portable and reliable solution for epileptic seizure monitoring in clinical and home applications.

  16. Computer Jet-Engine-Monitoring System

    Science.gov (United States)

    Disbrow, James D.; Duke, Eugene L.; Ray, Ronald J.

    1992-01-01

    "Intelligent Computer Assistant for Engine Monitoring" (ICAEM), computer-based monitoring system intended to distill and display data on conditions of operation of two turbofan engines of F-18, is in preliminary state of development. System reduces burden on propulsion engineer by providing single display of summary information on statuses of engines and alerting engineer to anomalous conditions. Effective use of prior engine-monitoring system requires continuous attention to multiple displays.

  17. Computer Jet-Engine-Monitoring System

    Science.gov (United States)

    Disbrow, James D.; Duke, Eugene L.; Ray, Ronald J.

    1992-01-01

    "Intelligent Computer Assistant for Engine Monitoring" (ICAEM), computer-based monitoring system intended to distill and display data on conditions of operation of two turbofan engines of F-18, is in preliminary state of development. System reduces burden on propulsion engineer by providing single display of summary information on statuses of engines and alerting engineer to anomalous conditions. Effective use of prior engine-monitoring system requires continuous attention to multiple displays.

  18. Digital Solution to Mining Image Monitor System

    Institute of Scientific and Technical Information of China (English)

    刘越男; 孙继平; 苏辉; 那景芳

    2001-01-01

    The thesis describes an advanced digital solution to mining digital image monitor system, which makes up the shortage of the traditional mining analog image monitor. It illustrates the system components and how to choose the encoder bandwidth of the system. The problem of image multicast and its solution in LAN are also discussed.

  19. Software For Monitoring VAX Computer Systems

    Science.gov (United States)

    Farkas, Les; Don, Ken; Lavery, David; Baron, Amy

    1994-01-01

    VAX Continuous Monitoring System (VAXCMS) computer program developed at NASA Headquarters to aid system managers in monitoring performances of VAX computer systems through generation of graphic images summarizing trends in performance metrics over time. VAXCMS written in DCL and VAX FORTRAN for use with DEC VAX-series computers running VMS 5.1 or later.

  20. 76 FR 13432 - In the Matter of Certain Display Devices, Including Digital Televisions and Monitors II; Notice...

    Science.gov (United States)

    2011-03-11

    ... COMMISSION In the Matter of Certain Display Devices, Including Digital Televisions and Monitors II; Notice of... United States after importation of certain display devices, including digital televisions and monitors by... importation, or the sale within the United States after importation of certain display devices, including...

  1. Monitoring by holographic radar systems

    Science.gov (United States)

    Catapano, Ilaria; Crocco, Lorenzo; Affinito, Antonio; Gennarelli, Gianluca; Soldovieri, Francesco

    2013-04-01

    Nowadays, radar technology represents a significant opportunity to collect useful information for the monitoring and conservation of critical infrastructures. Radar systems exploit the non-invasive interaction between the matter and the electromagnetic waves at microwave frequencies. Such an interaction allows obtaining images of the region under test from which one can infer the presence of potential anomalies such as deformations, cracks, water infiltrations, etc. This information turns out to be of primary importance in practical scenarios where the probed structure is in a poor state of preservation and renovation works must be planned. In this framework, the aim of this contribution is to describe the potentialities of the holographic radar Rascan 4/4000, a holographic radar developed by Remote Sensing Laboratory of Bauman Moscow State Technical University, as a non-destructive diagnostic tool capable to provide, in real-time, high resolution subsurface images of the sounded structure [1]. This radar provides holograms of hidden anomalies from the amplitude of the interference signal arising between the backscattered signal and a reference signal. The performance of the holographic radar is appraised by means of several experiments. Preliminary tests concerning the imaging below the floor and inside wood structures are carried out in controlled conditions at the Electromagnetic Diagnostic Laboratory of IREA-CNR. After, with reference to bridge monitoring for security aim, the results of a measurement campaign performed on the Musmeci bridge are presented [2]. Acknowledgments This research has been performed in the framework of the "Active and Passive Microwaves for Security and Subsurface imaging (AMISS)" EU 7th Framework Marie Curie Actions IRSES project (PIRSES-GA-2010-269157). REFERENCES [1] S. Ivashov, V. Razevig, I. Vasilyev, A. Zhuravlev, T. Bechtel, L. Capineri, The holographic principle in subsurface radar technology, International Symposium to

  2. 78 FR 68861 - Certain Navigation Products, Including GPS Devices, Navigation and Display Systems, Radar Systems...

    Science.gov (United States)

    2013-11-15

    ... COMMISSION Certain Navigation Products, Including GPS Devices, Navigation and Display Systems, Radar Systems... the United States after importation of certain navigation products, including GPS devices, navigation... products, including GPS devices, navigation and display systems, radar systems, navigational aids,...

  3. Distributed Monitoring System Based on ICINGA

    CERN Document Server

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  4. Wireless monitoring of structural components of wind turbines including tower and foundations

    Science.gov (United States)

    Wondra, B.; Botz, M.; Grosse, C. U.

    2016-09-01

    Only few large wind turbines contain an extensive structural health monitoring (SHM) system. Such SHM systems could provide deeper insight into the real load history of a wind turbine along its standard lifetime of 20 years and support a justified extension of operation beyond the original intended period. This paper presents a new concept of a wireless SHM system based on acceleration measurement sensor nodes to permanently record acceleration of the tower structure at different heights. Exploitation of acceleration data and its referring position on the turbine tower enables calculation of vibration frequencies, their amplitudes and subsequently eigenmodes. Tower heights of 100 m and more are within the transmission range of wireless nodes, enabling a complete surveillance of the tower in three dimensions without the need for long cabling or electric signal amplification. Mounting of the sensor nodes on the tower is not limited to a few positions by the presence of an electric cable anymore. Still a comparison between data recorded by wireless sensors and data recorded by high-resolution wire-based sensors shows that the present resolution of the wireless sensors has to be improved to record accelerations more accurately and thus analyze vibration frequencies more precisely.

  5. Modernizing the monitoring of Mass Storage systems

    CERN Document Server

    Terrien, Alexandre

    2016-01-01

    The monitoring of a system is essential to ensure its efficiency. On a computer system, this monitoring is partly done via the analysis of log messages. The monitoring of CASTOR, a mass-storage system responsible for the storage of 150Pb of scientific data at CERN, was being done with tools developed by the IT-ST-FDO section. Those tools recently encountered some performance limitations due to the increase in the quantity of data produced by CERN's experiments. In this paper, I will describe how I managed to modernize CASTOR's monitoring tools by leveraging services centrally managed by CERN's IT department.

  6. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  7. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming;

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  8. Downhole Vibration Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2007-09-30

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. The key feature of this system is its use of a magnetorheological fluid (MRF) to allow the damping coefficient to be changed extensively, rapidly and reversibly without the use of mechanical valves, but only by the application of a current. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Much of the effort was devoted to the design and testing of the MRF damper, itself. The principal objectives of Phase II were: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in a drilling laboratory. Phase II concluded on January 31, 2006, and a final report was issued. Work on Phase III of the project began during the first quarter, 2006, with the objectives of building precommercial prototypes, testing them in a drilling laboratory and the field; developing and implementing a commercialization plan. All of these have been accomplished. The Downhole Vibration Monitoring & Control System (DVMCS) prototypes have been successfully proven in testing at the TerraTek drilling facility and at the Rocky Mountain Oilfield Test Center (RMOTC.) Based on the results of these tests, we have signed a definitive development and distribution agreement with Smith, and commercial deployment is underway. This current version of the DVMCS monitors and controls axial vibrations. Due to time and budget constraints of this program, it was not possible to complete a system that would also deal with lateral and torsional (stick-slip) vibrations as originally planned; however, this effort is continuing without DOE

  9. Project Design Concept for Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    MCGREW, D.L.

    2000-10-02

    This Project Design Concept represents operational requirements established for use in design the tank farm Monitoring and Control System. These upgrades are included within the scope of Project W-314, Tank Farm Restoration and Safe Operations.

  10. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    , and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program......A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface...

  11. Remote computer monitors corrosion protection system

    Energy Technology Data Exchange (ETDEWEB)

    Kendrick, A.

    Effective corrosion protection with electrochemical methods requires some method of routine monitoring that provides reliable data that is free of human error. A test installation of a remote computer control monitoring system for electrochemical corrosion protection is described. The unit can handle up to six channel inputs. Each channel comprises 3 analog signals and 1 digital. The operation of the system is discussed.

  12. Applied Data Analysis in Energy Monitoring System

    Directory of Open Access Journals (Sweden)

    Kychkin А.V.

    2016-08-01

    Full Text Available Software and hardware system organization is presented as an example for building energy monitoring of multi-sectional lighting and climate control / conditioning needs. System key feature is applied office energy data analysis that allows to provide each type of hardware localized work mode recognition. It is based on general energy consumption profile with following energy consumption and workload evaluation. Applied data analysis includes primary data processing block, smoothing filter, time stamp identification block, clusterization and classification blocks, state change detection block, statistical data calculation block. Time slot consumed energy value and slot time stamp are taken as work mode classification main parameters. Energy data applied analysis with HIL and OpenJEVis visualization system usage experimental research results for chosen time period has been provided. Energy consumption, workload calculation and eight different states identification has been executed for two lighting sections and one climate control / conditioning emulating system by integral energy consumption profile. Research has been supported by university internal grant №2016/PI-2 «Methodology development of monitoring and heat flow utilization as low potential company energy sources».

  13. Research and Construction the Net Monitor System

    Directory of Open Access Journals (Sweden)

    Ruining Huang

    2012-07-01

    Full Text Available A Net Monitor system is presented in this paper. The system is based on STMicroelectronics board FLTK3D, which provides hardware platform for TV functions--3D film, IPTV, 3D game, cable television and so on. The whole system includes the Linux Operating System (OS, embedded web browser, Media player, clouding applications, video conference and 3D game. It utilizes the reference model of the CLFS (Cross Linux From Scratches principle to construct the embedded Linux OS. Cloud applications are focused on remote control and access to the cloud data center. The ESX/view client provides this function for its secure access to the data center and maintainability. With the development of IPTV technology, light cross-platform web browser, media player and video conference are implemented. The Net Monitor can integrate cloud applications, web browser, media player, video conference and so on in just one platform with lower cost than other platforms on buying extra hardware and software, so it will brings convenient and benefit to people.

  14. Developing a system for AMB Monitoring

    CERN Document Server

    Hancock, Thomas

    2015-01-01

    A monitoring system for the Associative Memory Boards (AMBs) of the Fast Tracker (FTK) is developed and tested. This system is able to read out status register values from AMBs and publish them to the Information Service (IS). The system is designed so as to be easily extensible to other boards of FTK, and this is demonstrated through an extension of the systems to be able to monitor FTK Auxiliary cards. Future work will involve extensions to other FTK boards and providing a system to read from IS and present the user with the monitoring data.

  15. A remote condition monitoring system for wind-turbine based DG systems

    Science.gov (United States)

    Ma, X.; Wang, G.; Cross, P.; Zhang, X.

    2012-05-01

    In this paper, a remote condition monitoring system is proposed, which fundamentally consists of real-time monitoring modules on the plant side, a remote support centre and the communications between them. The paper addresses some of the key issues related on the monitoring system, including i) the implementation and configuration of a VPN connection, ii) an effective database system to be able to handle huge amount of monitoring data, and iii) efficient data mining techniques to convert raw data into useful information for plant assessment. The preliminary results have demonstrated that the proposed system is practically feasible and can be deployed to monitor the emerging new energy generation systems.

  16. Structural health monitoring using genetic fuzzy systems

    CERN Document Server

    Pawar, Prashant M

    2014-01-01

    The high profile of structural health monitoring (SHM) will add urgency to this detailed treatment of intelligent SHM development and implementation via the evolutionary system, which uses a genetic algorithm to automate the development of the fuzzy system.

  17. Sport monitoring with smart wearable system.

    Science.gov (United States)

    Perego, Paolo; Moltani, Alessia; Andreoni, Giuseppe

    2012-01-01

    This work presents a new system for sport monitoring. The system was composed of a t-shirt with two textile electrodes and two devices for the acquisition, storage, processing and visualization of the signals. The systems allows monitoring both ECG signal (raw and processed heart-rate) and 3 axial acceleration (raw and step counter). The systems were tested in different conditions during some races; we report the results on three subjects during a skyrunning race.

  18. Forest dynamics, SILVI-STAR : a comprehensive monitoring system

    NARCIS (Netherlands)

    Koop, H.

    1989-01-01

    To learn about the interactions between individual trees and between trees and other forest organisms, long-term monitoring of spontaneous forest development is necessary. A complete monitoring system has been developed including a computer package for analysis of long-term forest dynamics

  19. Forest dynamics. Silvi-star: a comprehensive monitoring system.

    NARCIS (Netherlands)

    Koop, H.

    1989-01-01

    To learn about the interactions between individual trees and between trees and other forest organisms, long-term monitoring of spontaneous forest development is necessary. A complete monitoring system has been developed including a computer package for analysis of long-term forest dynamics observati

  20. The design of remote temperature monitoring system

    Science.gov (United States)

    Li, Biqing; Li, Zhao; Wei, Liuren

    2017-08-01

    This design is made on the basis of the single-chip microcomputer remote temperature monitoring system. STC89C51RC is the main core part, this design use the sensor DHT11 of temperature or humidity and wireless transceiver NRF24L01 the temperature of the test site for long-range wireless measurement and monitoring. The design contains the main system and the small system, of which the main system can show the actual test site temperature and humidity values, voice broadcast, out of control and receive data alarm function; The small system has the function of temperature and humidity, temperature monitoring and sending data. After debugging, the user customizable alarm upper and lower temperature, when the temperature exceeds limit value, the main system of buzzer alarm immediately. The system has simple structure, complete functions and can alarm in time, it can be widely used remote temperature acquisition and monitoring of the site.

  1. Parabasal theory for plane-symmetric systems including freeform surfaces

    Science.gov (United States)

    Abd El-Maksoud, Rania H.; Hillenbrand, Matthias; Sinzinger, Stefan

    2014-03-01

    An extension of paraxial theory to systems with a single plane of symmetry is provided. This parabasal model is based on the evaluation of a differential region around the reference ray that is defined by the center of the object and the center of the stop. To include freeform surfaces in this model, the local curvatures at the intersection point of the reference ray and the surface are evaluated. As an application, a generalized Scheimpflug principle is presented. The validity of the derived formulas is tested for highly tilted surfaces and is in good agreement with the exact ray tracing results. The analytical expressions are used to provide a first-order layout design of a planar imaging system.

  2. The CERN GSM monitoring system

    CERN Document Server

    Ghabrous, C

    2010-01-01

    This paper presents the way CERN has approached the problem of monitoring its own GSM infrastructure, especially in the Large Hadron Collider (LHC) accelerator tunnel and other underground facilities, where a leaky feeder cable carries mobile phone signals, and where this technology is the only means for inter-personnel communications

  3. How to include farmers in the emission trading system?

    DEFF Research Database (Denmark)

    Svendsen, Gert Tinggaard

    2011-01-01

    The EU has committed itself to an ambitious 20 % reduction of greenhouse gases (GHG) by 2020 compared to the 1990 emissions level. Moreover, the EU goal beyond 2012 is to strengthen, expand and improve climate change initiatives. Therefore, there is a strong need to consider more carefully how to...... to integrate as many sectors as possible in these efforts. Farmers, however, do not trade GHG under the Kyoto agreement. The idea of including farmers in a national emission trading system has been launched in Australia but it has not yet been applied to the EU....

  4. How to include farmers in the emission trading system?

    DEFF Research Database (Denmark)

    Svendsen, Gert Tinggaard

    2011-01-01

    The EU has committed itself to an ambitious 20 % reduction of greenhouse gases (GHG) by 2020 compared to the 1990 emissions level. Moreover, the EU goal beyond 2012 is to strengthen, expand and improve climate change initiatives. Therefore, there is a strong need to consider more carefully how to...... to integrate as many sectors as possible in these efforts. Farmers, however, do not trade GHG under the Kyoto agreement. The idea of including farmers in a national emission trading system has been launched in Australia but it has not yet been applied to the EU....

  5. Monitoring of distributed systems using historical debuggers

    Science.gov (United States)

    Komorowski, Michał

    2016-09-01

    Historical debuggers are tools that give insight into the history of program execution. This functionality is usually achieved by recording logs (execution traces). There are many tools of this kind but only limited number of them is capable of monitoring of distributed systems. It is a serious problem as the majority of contemporary information systems has distributed nature. This paper shows how to monitor and trace distributed systems using historical debuggers that were designed to work locally. The proposed concept consists of an approach for the correlation of execution traces that were recorded on different nodes of a distributed system that was monitored.

  6. Embedded multiparametric system for volcano monitoring

    Science.gov (United States)

    Moure, David; Torres, Pedro A.; Meletlidis, Stavros; Lopez, Carmen; José Blanco, María

    2014-05-01

    A low cost and low power consumption multiparametric system designed for volcano monitoring is presented. Once tested with various sensors, at present it is installed in two locations in Tenerife, Canary Islands, acquiring and transmitting data in real time. The system is based on a commercial board (Raspberry Pi®, RPi®) that uses an embedded ARMTM processor with a Debian (Wheezy-Raspbian) Linux Operating System. This configuration permits different standard communication systems between devices as USB and ETHERNET, and also communication with integrated circuits is possible. The whole system includes this platform and self-developed hardware and software. Analog signals are acquired at an expansion board with an ADC converter with three 16 bits channels. This board, which is powered directly from the RPi®, provides timing to the sampling data using a Real Time Clock (RTC). Two serial protocols (I2C and SPI) are responsible for communications. Due to the influence of atmospheric phenomena on the volcano monitoring data, the system is complemented by a self-developed meteorological station based on ArduinoCC and low cost commercial sensors (atmospheric pressure, humidity and rainfall). It is powered with the RPi® and it uses a serial protocol for communications. Self-developed software run under Linux OS and handles configuration, signal acquisition, data storage (USB storage or SD card) and data transmission (FTP, web server). Remote configuration, data plotting and downloading is available through a web interface tool. Nowadays, the system is used for gravimetric and oceanic tides data acquisition in Tenerife and soon it will be applied for clinometric data.

  7. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  8. Developing Automatic System Monitoring Solution for Accanto Systems Customer Care

    OpenAIRE

    Mikkola, Markku

    2015-01-01

    The goal of the development work was to document the requirements, to develop and deploy an automatic system monitoring solution for Accanto Systems Customer Care. This final report describes Icinga Core as the backbone of the monitoring solution and presents the actual use case that was implemented for Accanto Systems. The client for this work was Accanto Systems Customer Care department which had been suffering a long time with high work load due to increased basic system monitoring tas...

  9. Remote monitoring of LED lighting system performance

    Science.gov (United States)

    Thotagamuwa, Dinusha R.; Perera, Indika U.; Narendran, Nadarajah

    2016-09-01

    The concept of connected lighting systems using LED lighting for the creation of intelligent buildings is becoming attractive to building owners and managers. In this application, the two most important parameters include power demand and the remaining useful life of the LED fixtures. The first enables energy-efficient buildings and the second helps building managers schedule maintenance services. The failure of an LED lighting system can be parametric (such as lumen depreciation) or catastrophic (such as complete cessation of light). Catastrophic failures in LED lighting systems can create serious consequences in safety critical and emergency applications. Therefore, both failure mechanisms must be considered and the shorter of the two must be used as the failure time. Furthermore, because of significant variation between the useful lives of similar products, it is difficult to accurately predict the life of LED systems. Real-time data gathering and analysis of key operating parameters of LED systems can enable the accurate estimation of the useful life of a lighting system. This paper demonstrates the use of a data-driven method (Euclidean distance) to monitor the performance of an LED lighting system and predict its time to failure.

  10. Persistence of Free Plasmid DNA in Soil Monitored by Various Methods, Including a Transformation Assay

    Science.gov (United States)

    Romanowski, Gerd; Lorenz, Michael G.; Sayler, Gary; Wackernagel, Wilfried

    1992-01-01

    The persistence and stability of free plasmid pUC8-ISP DNA introduced into 10-g samples of various soils and kept at 23°C were monitored over a period of 60 days. The soils were sampled at a plant science farm and included a loamy sand soil (no. 1), a clay soil (no. 2), and a silty clay soil (no. 3). Four different methods allowed monitoring of (i) the production of acid-soluble radioactive material from [3H]thymidine-labeled plasmid DNA, (ii) the decrease of hybridizing nucleotide sequences in slot blot analysis, (iii) the loss of plasmid integrity measured by Southern hybridization, and (iv) the decay of the biological activity as determined by transformation of Ca2+-treated Escherichia coli cells with the DNA extracted from soil. Acid-soluble material was not produced within the first 24 h but then increased to 45% (soil no. 1), 27% (soil no. 2), and 77% (soil no. 3) until the end of incubation. A quite parallel loss of material giving a slot blot hybridization signal was observed. Southern hybridization indicated that after 1 h in the soils, plasmid DNA was mostly in the form of circular and full-length linear molecules but that, depending on the soil type, after 2 to 5 days full-length plasmid molecules were hardly detectable. The transforming activity of plasmid DNA reextracted from the soils followed inactivation curves over 2 to 4 orders of magnitude and dropped below the detection limit after 10 days. The inactivation was slower in soil no. 2 (28.2-h half-life time of the transforming activity of a plasmid molecule) than in soils no. 3 (15.1 h) and no. 1 (9.1 h). The studies provide data on the persistence of free DNA molecules in natural bacterial soil habitats. The data suggest that plasmid DNA may persist long enough to be available for uptake by competent recipient cells in situ. Images PMID:16348772

  11. EM Monitoring of Crustal Processes Including the Use of the Network-MT Observations

    Science.gov (United States)

    Uyeshima, Makoto

    2007-05-01

    There are several kinds of coupling mechanisms which can convert mechanical, chemical or thermal energies due to seismic or volcanic activities into electromagnetic energies. As a result of concentrated efforts in laboratory and theoretical research, the basic relationship between the intensity of electromagnetic sources and changes in mechanical, chemical and thermal state is becoming established. Also with the progress of the electromagnetic simulation techniques, it has been possible to evaluate in situ sensitivity. Based on this progress and also due to extensive improvement in measuring techniques, many field experiments have been performed to elucidate subsurface geophysical processes underlying the preparation stage, onset, and subsequent healing stage of earthquakes and volcanic eruptions. In volcanic studies, many studies have reported the measurement of electromagnetic signals which were successfully interpreted in terms of various driving mechanisms. Although there have been numerous reports about the existence of precursory electromagnetic signals in seismic studies, only a few of them could be successfully explained by the proposed mechanisms, whereas coseismic phenomena are often consistent with those mechanisms including the absence of detectable signals. In many cases, one or two orders of higher sensitivity were required, especially for precursory signals. Generally, electromagnetic methods are more sensitive to near-surface phenomena. It will be necessary to discriminate electromagnetic signals due to these near-surface sources, which often possess no relationship with the crustal activities. Further efforts to enhance in situ sensitivity through improvements in observation techniques and in data processing techniques are recommended. At the same time, multi-disciplinary confirmation against the validity of electromagnetic phenomena will inevitably be necessary. A Network-MT observation technique has been developed to determine large-scale deep

  12. Automated wind-icing monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Horokhov, Y.; Nekrasov, Y.; Turbin, S. [Donbas National Academy of Civil Engineering and Architecture, Makeyevka, Donetsk (Ukraine); Grimud, G. [NEC Ukrenergo, Kiev (Ukraine)

    2005-07-01

    The development of automated wind-icing monitoring systems (AWIMS) has increased the operational reliability of existing overhead lines through a more accurate prediction of icing events in the Ukraine. The systems are capable of operating without the presence of personnel, and allow operators to immediately obtain information about icing processes. The systems provide statistically significant sets of data for determining and predicting loading conditions, as well as combining measurements of icing mass, wind speed and direction, temperature and humidity. An outline of the principles of AWIMS was presented in paper, as well as a description of the system's architecture and operating principles. The monitoring system consists of an ice mass measuring device; a strain gauge sensor; a photoelectric pickup to determine perpendicular mean wind direction; and a wire simulator. The measuring devices are installed 10 meters above ground. Data is transmitted every 30 minutes to a central information office, where information is processed and stored. Details of the ultrasonic anemometer for wind measurements as well as the devices used for humidity and temperature measurement were presented. The AWIMS computer software measures 6 climatic parameters: wind speed; wind direction; air temperature; humidity; icing mass; and wind pressure on ice-covered wires. Results of a series of tests were presented which included a weather station data analysis and a comparison of the AWIMS with standard climatic loads. An analysis of overhead line failure statistical data was also conducted. Spatial icing distributions were used to calculate the threshold sensitivity for the AWIMS. As estimation of overhead lines density per square kilometer showed was made to determine placement of the systems. It was concluded that 8 more AWIMS will be installed in the following year. 3 refs., 10 figs.

  13. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  14. Advanced methodology for generation expansion planning including interconnected systems

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, M.; Yokoyama, R.; Yasuda, K. [Tokyo Metropolitan Univ. (Japan); Sasaki, H. [Hiroshima Univ. (Japan); Ogimoto, K. [Electric Power Development Co. Ltd., Tokyo (Japan)

    1994-12-31

    This paper reviews advanced methodology for generation expansion planning including interconnected systems developed in Japan, putting focus on flexibility and efficiency in a practical application. First, criteria for evaluating flexibility of generation planning considering uncertainties are introduced. Secondly, the flexible generation mix problem is formulated as a multi-objective optimization with more than two objective functions. The multi-objective optimization problem is then transformed into a single objective problem by using the weighting method, to obtain the Pareto optimal solution, and solved by a dynamics programming technique. Thirdly, a new approach for electric generation expansion planning of interconnected systems is presented, based on the Benders Decomposition technique. That is, large scale generation problem constituted by the general economic load dispatch problem, and several sub problems which are composed of smaller scale isolated system generation expansion plans. Finally, the generation expansion plan solved by an artificial neural network is presented. In conclusion, the advantages and disadvantages of this method from the viewpoint of flexibility and applicability to practical generation expansion planning are presented. (author) 29 refs., 10 figs., 4 tabs.

  15. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  16. A conceptual framework for intelligent monitoring systems

    Science.gov (United States)

    Juliano, Thomas; Meegoda, Jay; Niver, Edip; Watts, Daniel; Wadhawan, Sameer; Finlayson, Richard

    2005-05-01

    This paper discusses the conceptual development of a continuously monitored intelligent system for underground infrastructure. The proposed sensors are based on advanced coupling and refinement of several technologies: electrically conducting composite pipe (ECCP), electrochemical impedance spectroscopy (EIS) and time domain reflectometry (TDR). A significant benefit gleaned from the combination of these technologies is that the resulting system may be used on non-metallic, as well as, metallic pipes. In addition, the synergism of the technologies obtains the maximum information regarding defect location and characterization. The monitoring signal, waveguides, and damage sensor are also discussed, as well as, the data fusion, dynamic modeling and simulation requirements for the intelligent monitoring system.

  17. Research on monitoring system for slope deformation

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-sheng; ZHANG Xue-zhuang; WANG Ai-gong

    2007-01-01

    The monitoring system for slope deformation which bases on Leica (TCA series)was researched and developed. This system consists of electronic total stations, high precision thermometer, digital barometer, photoelectric frequency adjustor and other related instruments and data collection and processing software. The system can monitor a series of targets automatically to obtain accurate data of distance at predetermined time, besides,it can timely display targets' coordinates and deformation value, velocity, etc. in graph as well. To compare of the results of different monitoring time, we can find the problems of mine slope deformation rapidly and accurately.

  18. Test Results of a Phi Monitoring System

    CERN Document Server

    Figueroa, Carlos; Burgos, C; Ferrrando, A; Matorras, Francisco; Molinero, Antonio; Rodriguo, T; Shvachkin, V

    1997-01-01

    The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).

  19. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing...

  20. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  1. Data processing for water monitoring system

    Science.gov (United States)

    Monford, L.; Linton, A. T.

    1978-01-01

    Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

  2. Economic analysis of condition monitoring systems for offshore wind turbine sub-systems

    DEFF Research Database (Denmark)

    May, Allan; MacMillan, David; Thöns, Sebastian

    2015-01-01

    The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...

  3. Kalaeloa Energy System Redevelopment Options Including Advanced Microgrids.

    Energy Technology Data Exchange (ETDEWEB)

    Hightower, Marion Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Baca, Michael J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); VanderMey, Carissa [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    In June 2016, the Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) in collaboration with the Renewable Energy Branch for the Hawaii State Energy Office (HSEO), the Hawaii Community Development Authority (HCDA), the United States Navy (Navy), and Sandia National Laboratories (Sandia) established a project to 1) assess the current functionality of the energy infrastructure at the Kalaeloa Community Development District, and 2) evaluate options to use both existing and new distributed and renewable energy generation and storage resources within advanced microgrid frameworks to cost-effectively enhance energy security and reliability for critical stakeholder needs during both short-term and extended electric power outages. This report discusses the results of a stakeholder workshop and associated site visits conducted by Sandia in October 2016 to identify major Kalaeloa stakeholder and tenant energy issues, concerns, and priorities. The report also documents information on the performance and cost benefits of a range of possible energy system improvement options including traditional electric grid upgrade approaches, advanced microgrid upgrades, and combined grid/microgrid improvements. The costs and benefits of the different improvement options are presented, comparing options to see how well they address the energy system reliability, sustainability, and resiliency priorities identified by the Kalaeloa stakeholders.

  4. A plasma process monitor/control system

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J.O.; Ward, P.P.; Smith, M.L. [Sandia National Labs., Albuquerque, NM (United States); Markle, R.J. [Advanced Micro Devices, Inc., Austin, TX (United States)

    1997-08-01

    Sandia National Laboratories has developed a system to monitor plasma processes for control of industrial applications. The system is designed to act as a fully automated, sand-alone process monitor during printed wiring board and semiconductor production runs. The monitor routinely performs data collection, analysis, process identification, and error detection/correction without the need for human intervention. The monitor can also be used in research mode to allow process engineers to gather additional information about plasma processes. The plasma monitor can perform real-time control of support systems known to influence plasma behavior. The monitor can also signal personnel to modify plasma parameters when the system is operating outside of desired specifications and requires human assistance. A notification protocol can be selected for conditions detected in the plasma process. The Plasma Process Monitor/Control System consists of a computer running software developed by Sandia National Laboratories, a commercially available spectrophotometer equipped with a charge-coupled device camera, an input/output device, and a fiber optic cable.

  5. Advanced Systems for Monitoring Underwater Sounds

    Science.gov (United States)

    Lane, Michael; Van Meter, Steven; Gilmore, Richard Grant; Sommer, Keith

    2007-01-01

    The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity

  6. Systems and method for lagrangian monitoring of flooding conditions

    KAUST Repository

    Claudel, Christian G.

    2015-12-17

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  7. System And Method For Monitoring Traffic While Preserving Personal Privacy

    KAUST Repository

    Canepa, Edward

    2015-08-06

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  8. A System for Monitoring Affective Objectives.

    Science.gov (United States)

    Hughes, Abby L.; Frommer, Karen

    1982-01-01

    Based on the belief that affective education cannot be left to an informal process of "warm fuzzies," the system described here is a structured instructional program with specific affective objectives and a scale for monitoring achievement. (Author/JM)

  9. Automatic calorimetry system monitors RF power

    Science.gov (United States)

    Harness, B. W.; Heiberger, E. C.

    1969-01-01

    Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

  10. Modular biowaste monitoring system conceptual design

    Science.gov (United States)

    Fogal, G. L.

    1974-01-01

    The objective of the study was to define requirements and generate a conceptual design for a Modular Biowaste Monitoring System for specifically supporting shuttle life science experimental and diagnostic programs.

  11. Class 3 Tracking and Monitoring System Report

    Energy Technology Data Exchange (ETDEWEB)

    Safely, Eugene; Salamy, S. Phillip

    1999-11-29

    The objective of Class 3 tracking system are to assist DOE in tracking and performance and progress of these projects and to capture the technical and financial information collected during the projects' monitoring phase. The captured information was used by DOE project managers and BDM-Oklahoma staff for project monitoring and evaluation, and technology transfer activities. The proposed tracking system used the Class Evaluation Executive Report (CLEVER), a relation database for storing and disseminating class project data; GeoGraphix, a geological and technical analysis and mapping software system; the Tertiary Oil Recovery Information System (TORIS) database; and MS-Project, a project management software system.

  12. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  13. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    OpenAIRE

    Inna Pivovarova

    2016-01-01

    The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monito...

  14. Augmentation of the In Vivo Elastic Properties Measurement System to Include Bulk Properties

    Science.gov (United States)

    2015-09-30

    vivo shear and bulk properties of cetacean soft tissues, including jaw fats and brain. The ultimate goal is to field a prototype system for...pattern. A second ultrasonic transducer monitors the tissue displacement along the ultrasound beam axis, and supports an enhanced embodiment of an...Figure 1. CFE concept. Color contour plots illustrate soft tissue displacements parallel to the transducer beam axes. (A) The annular force generation

  15. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  16. Operations Monitoring Assistant System Design

    Science.gov (United States)

    1986-07-01

    subsections address these system , tesi ~n issues in tiirn. 3.1 OMA SYSTEM OVERVIEW Figure 3-1 presents the concept in Figure 2-1 in more detail, from an OMA...issues---a local agent cannot realistically Tell -he centralized planner everything about its current situation. and must instead ,t- cide what relevant

  17. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  18. Heart monitoring systems--a review.

    Science.gov (United States)

    Jain, Puneet Kumar; Tiwari, Anil Kumar

    2014-11-01

    To diagnose health status of the heart, heart monitoring systems use heart signals produced during each cardiac cycle. Many types of signals are acquired to analyze heart functionality and hence several heart monitoring systems such as phonocardiography, electrocardiography, photoplethysmography and seismocardiography are used in practice. Recently, focus on the at-home monitoring of the heart is increasing for long term monitoring, which minimizes risks associated with the patients diagnosed with cardiovascular diseases. It leads to increasing research interest in portable systems having features such as signal transmission capability, unobtrusiveness, and low power consumption. In this paper we intend to provide a detailed review of recent advancements of such heart monitoring systems. We introduce the heart monitoring system in five modules: (1) body sensors, (2) signal conditioning, (3) analog to digital converter (ADC) and compression, (4) wireless transmission, and (5) analysis and classification. In each module, we provide a brief introduction about the function of the module, recent developments, and their limitation and challenges.

  19. Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion monitoring

    NARCIS (Netherlands)

    Serov, Alexander N.; Nieland, Janharm; Oosterbaan, Sjoerd; Mul, de Frits F.M.; Kranenburg, van Herma; Bekman, Herman H.P.Th.; Steenbergen, Wiendelt

    2006-01-01

    An integrated optoelectronic probe with small dimensions, for direct-contact laser Doppler blood flow monitoring has been realized. A vertical cavity surface emitting laser (VCSEL), and a chip with photodetectors and all necessary electronics are integrated in a miniature probe head connected to a l

  20. Integrated Optoelectronic Probe Including a Vertical Cavity Surface Emitting Laser for Laser Doppler Perfusion Monitoring

    NARCIS (Netherlands)

    Serov, A.N.; Nieland, J.; Oosterbaan, S.; Steenbergen, W.; Bekman, H.H.P.T.; Mul, F.F.M. de; Kranenburg, H. van

    2006-01-01

    An integrated optoelectronic probe with small dimensions, for direct-contact laser Doppler blood flow monitoring has been realized. A vertical cavity surface emitting laser (VCSEL), and a chip with photodetectors and all necessary electronics are integrated in a miniature probe head connected to a l

  1. An Expert System Applied in Construction Water Quality Monitoring

    Directory of Open Access Journals (Sweden)

    Leila Ooshaksaraie

    2011-01-01

    Full Text Available Problem statement: An untoward environmental impact of urban growth in Malaysia has been deterioration in a number of watercourses due to severe siltation and other pollutants from the construction site. Water quality monitoring is a plan for decision makers to take into account the adverse impacts of construction activities on the receiving water bodies. It is also a process for collecting the construction water quality monitoring, baseline data and standard level. Approach: In recent years, expert systems have been used extensively in different applications areas including environmental studies. In this study, expert system software -CWQM- developed by using Microsoft Visual Basic was introduced. CWQM to be used for water quality monitoring during construction activities was designed based on the legal process in Malaysia. Results: According to the water quality monitoring regulation enacted in Malaysia, construction activities require mandatory water quality monitoring plans duly approved by Department of Environment before staring activities. CWQM primarily aims to provide educational and support system for water quality monitoring engineers and decision-makers during construction activities. It displays water quality monitoring plan in report form, water sampling location in GIS format and water quality monitoring data in graph. Conclusion: When the use of CWQM in construction water quality monitoring becomes widespread, it is highly possible that it will be benefited in terms of having more accurate and objective decisions on construction projects which are mainly focused on reducing the stormwater pollution.

  2. Monitoring drug markets in the Internet age and the evolution of drug monitoring systems in Australia.

    Science.gov (United States)

    Burns, Lucy; Roxburgh, Amanda; Bruno, Raimondo; Van Buskirk, Joe

    2014-01-01

    In Australia, drug monitoring systems have been in place for more than a decade allowing for the measurement of ongoing trends in drug use and the detection of new drugs. The Drug Trends Unit at the National Drug and Alcohol Research Centre monitors drugs through four separate systems. The Illicit Drug Reporting System (IDRS) measures the price, purity, and availability of drugs that are primarily injected. The Ecstasy and Related Drugs Reporting System (EDRS) monitors psychostimulants that are used recreationally. The National Illicit Drugs Indicator Project (NIDIP) analyzes indicator data including drug-related hospitalizations and deaths. Finally, the Drugs and Emerging Technologies Project (DNeT) analyzes the role of the Internet in the procurement and use of novel psychoactive substances. This paper provides an overview of each component of the system, demonstrating how the system has evolved over time.

  3. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  4. Monitoring a petabyte scale storage system

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, Jon; Berman, Eileen; Huang, Chih-Hao; Moibenko, Alexander; Petravick, Don; Zalokar, Michael; /Fermilab

    2004-12-01

    Fermilab operates a petabyte scale storage system, Enstore, which is the primary data store for experiments' large data sets. The Enstore system regularly transfers greater than 15 Terabytes of data each day. It is designed using a client-server architecture providing sufficient modularity to allow easy addition and replacement of hardware and software components. Monitoring of this system is essential to insure the integrity of the data that is stored in it and to maintain the high volume access that this system supports. The monitoring of this distributed system is accomplished using a variety of tools and techniques that present information for use by a variety of roles (operator, storage system administrator, storage software developer, user). Essential elements of the system are monitored: performance, hardware, firmware, software, network, data integrity. We will present details of the deployed monitoring tools with an emphasis on the different techniques that have proved useful to each role. Experience with the monitoring tools and techniques, what worked and what did not will be presented.

  5. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  6. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  7. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, Gary L.; Meikrantz, David H.; Ely, Walter E.; Tuggle, Dale G.; Grafwallner, Ervin G.; Wickham, Keith L.; Maltrud, Herman R.; Baker, John D.

    1992-01-01

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter.

  8. Operations of cleanrooms during a forest fire including protocols and monitoring results

    Science.gov (United States)

    Matheson, Bruce A.; Egges, Joanne; Pirkey, Michael S.; Lobmeyer, Lynette D.

    2012-10-01

    Contamination-sensitive space flight hardware is typically built in cleanroom facilities in order to protect the hardware from particle contamination. Forest wildfires near the facilities greatly increase the number of particles and amount of vapors in the ambient outside air. Reasonable questions arise as to whether typical cleanroom facilities can adequately protect the hardware from these adverse environmental conditions. On Monday September 6, 2010 (Labor Day Holiday), a large wildfire ignited near the Boulder, Colorado Campus of Ball Aerospace. The fire was approximately 6 miles from the Boulder City limits. Smoke levels from the fire stayed very high in Boulder for the majority of the week after the fire began. Cleanroom operations were halted temporarily on contamination sensitive hardware, until particulate and non-volatile residue (NVR) sampling could be performed. Immediate monitoring showed little, if any effect on the cleanroom facilities, so programs were allowed to resume work while monitoring continued for several days and beyond in some cases. Little, if any, effect was ever noticed in the monitoring performed.

  9. Amplified OTDR systems for multipoint corrosion monitoring.

    Science.gov (United States)

    Nascimento, Jehan F; Silva, Marcionilo J; Coêlho, Isnaldo J S; Cipriano, Eliel; Martins-Filho, Joaquim F

    2012-01-01

    We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR) technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations.

  10. Amplified OTDR Systems for Multipoint Corrosion Monitoring

    Directory of Open Access Journals (Sweden)

    Joaquim F. Martins-Filho

    2012-03-01

    Full Text Available We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations.

  11. Scientific Opportunities for Monitoring at Environmental Remediation Sites (SOMERS): Integrated Systems-Based Approaches to Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Amoret L.; Wellman, Dawn M.; Deeb, Rula A.; Hawley, Elizabeth L.; Truex, Michael J.; Peterson, Mark; Freshley, Mark D.; Pierce, Eric M.; McCord, John; Young, Michael H.; Gilmore, Tyler J.; Miller, Rick; Miracle, Ann L.; Kaback, Dawn; Eddy-Dilek, Carol; Rossabi, Joe; Lee, Michelle H.; Bush, Richard P.; Beam , Paul; Chamberlain, G. M.; Marble, Justin; Whitehurst, Latrincy; Gerdes, Kurt D.; Collazo, Yvette

    2012-05-15

    Through an inter-disciplinary effort, DOE is addressing a need to advance monitoring approaches from sole reliance on cost- and labor-intensive point-source monitoring to integrated systems-based approaches such as flux-based approaches and the use of early indicator parameters. Key objectives include identifying current scientific, technical and implementation opportunities and challenges, prioritizing science and technology strategies to meet current needs within the DOE complex for the most challenging environments, and developing an integrated and risk-informed monitoring framework.

  12. Well Monitoring System For EGS

    Energy Technology Data Exchange (ETDEWEB)

    Normann, Randy [Perma Works LLC, Pattonville, TX (United States); Glowka, Dave [Perma Works LLC, Pattonville, TX (United States); Normann, Charles [Perma Works LLC, Pattonville, TX (United States); Parker, James [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Josip [Electrochemical Systems Inc, Knoxville, TN (United States); Dustan, Don [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Mario [Electrochemical Systems Inc, Knoxville, TN (United States); Sariri, Kouros [Frequency Management Int. Inc., Huntington Beach, CA (United States); Beal, Craig [MajiQ Technologies Inc., Somerville, MA (United States)

    2017-02-26

    This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

  13. The Combat-Wireless Health Monitoring System

    Science.gov (United States)

    2009-12-01

    not monitor concussions sustained by casualties. This article proposes the develop- ment of a new C-WHMS as an alterna- tive to the WPSM. The C-WHMS...monitoring system embedded within the Advanced Combat Helmet (ACH), which measures concussions sustained during the execution of combat operations. The...component of the C-WHMS, as embedded in the ACH. Concussions sus- tained by soldiers are a major concern of military leadership. The goal is to quickly

  14. An automated neutron monitor maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-09-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector`s functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  15. Monitoring and Technical Assistance Review System Notebook

    Science.gov (United States)

    Administration for Children & Families, 2008

    2008-01-01

    This notebook provides guidance on the Monitoring and Technical Assistance Review System (MTARS). The manual is intended for use by Administration on Developmental Disabilities (ADD) staff who manage MTARS and by MTARS reviewers who conduct site visit activities. The notebook is also designed to help Councils, Protection and Advocacy Systems, and…

  16. Psychometric aspects of pupil monitoring systems

    NARCIS (Netherlands)

    Glas, Cees A.W.; Geerlings, Hanneke

    2009-01-01

    Pupil monitoring systems support the teacher in tailoring teaching to the individual level of a student and in comparing the progress and results of teaching with national standards. The systems are based on the availability of an item bank calibrated using item response theory. The assessment of th

  17. Active system monitoring applied on wind turbines

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad; Parbo, Henrik

    2009-01-01

    A concept for active system monitoring (ASM) applied on wind turbines is presented in this paper. The concept is based on an injection of a small periodic auxiliary signal in the system. An investigation of the signature from the auxiliary input in residual (error) signals can then be applied...

  18. Remote container monitoring and surveillance systems

    Energy Technology Data Exchange (ETDEWEB)

    Resnik, W.M.; Kadner, S.P. [Aquila Technologies Group, Inc., Albuquerque, NM (United States)

    1995-12-31

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila`s Gemini All-Digital Surveillance System and on Aquila`s AssetLAN{trademark} asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN{trademark} technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed.

  19. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  20. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  1. Monitoring system of arch bridge for safety network management

    Science.gov (United States)

    Joo, Bong Chul; Yoo, Young Jun; Lee, Chin Hyung; Park, Ki Tae; Hwang, Yoon Koog

    2010-03-01

    Korea has constructed the safety management network monitoring test systems for the civil infrastructure since 2006 which includes airport structure, irrigation structure, railroad structure, road structure, and underground structure. Bridges among the road structure include the various superstructure types which are Steel box girder bridge, suspension bridge, PSC-box-girder bridge, and arch bridge. This paper shows the process of constructing the real-time monitoring system for the arch bridge and the measured result by the system. The arch type among various superstructure types has not only the structural efficiency but the visual beauty, because the arch type superstructure makes full use of the feature of curve. The main measuring points of arch bridges composited by curved members make a difference to compare with the system of girder bridges composited by straight members. This paper also shows the method to construct the monitoring system that considers the characteristic of the arch bridge. The system now includes strain gauges and thermometers, and it will include various sensor types such as CCTV, accelerometers and so on additionally. For the long term and accuracy monitoring, the latest optical sensors and equipments are applied to the system.

  2. A computational procedure for multibody systems including flexible beam dynamics

    Science.gov (United States)

    Downer, J. D.; Park, K. C.; Chiou, J. C.

    1990-01-01

    A computational procedure suitable for the solution of equations of motions for flexible multibody systems has been developed. The flexible beams are modeled using a fully nonlinear theory which accounts for both finite rotations and large deformations. The present formulation incorporates physical measures of conjugate Cauchy stress and covariant strain increments. As a consequence, the beam model can easily be interfaced with real-time strain measurements and feedback control systems. A distinct feature of the present work is the computational preservation of total energy for undamped systems; this is obtained via an objective strain increment/stress update procedure combined with an energy-conserving time integration algorithm which contains an accurate update of angular orientations. The procedure is demonstrated via several example problems.

  3. Monitoring SLAC High Performance UNIX Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lettsome, Annette K.; /Bethune-Cookman Coll. /SLAC

    2005-12-15

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface.

  4. Smart Sensor Network System For Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Javed Ali Baloch

    2012-07-01

    Full Text Available SSN (Smart Sensor Network systems could be used to monitor buildings with modern infrastructure, plant sites with chemical pollution, horticulture, natural habitat, wastewater management and modern transport system. To sense attributes of phenomena and make decisions on the basis of the sensed value is the primary goal of such systems. In this paper a Smart Spatially aware sensor system is presented. A smart system, which could continuously monitor the network to observe the functionality and trigger, alerts to the base station if a change in the system occurs and provide feedback periodically, on demand or even continuously depending on the nature of the application. The results of the simulation trials presented in this paper exhibit the performance of a Smart Spatially Aware Sensor Networks.

  5. International Remote Monitoring Project Embalse Nuclear Power Station, Argentina Embalse Remote Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Sigfried L.; Glidewell, Donnie D.; Bonino, Anibal; Bosler, Gene; Mercer, David; Maxey, Curt; Vones, Jaromir; Martelle, Guy; Busse, James; Kadner, Steve; White, Mike; Rovere, Luis

    1999-07-21

    The Autoridad Regulatoria Nuclear of Argentina (ARN), the International Atomic Energy Agency (IAEA), ABACC, the US Department of Energy, and the US Support Program POTAS, cooperated in the development of a Remote Monitoring System for nuclear nonproliferation efforts. This system was installed at the Embalse Nuclear Power Station last year to evaluate the feasibility of using radiation sensors in monitoring the transfer of spent fuel from the spent fuel pond to dry storage. The key element in this process is to maintain continuity of knowledge throughout the entire transfer process. This project evaluated the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguard efficiency. New technology has been developed to enhance the design of the system to include storage capability on board sensor platforms. This evaluation has led to design enhancements that will assure that no data loss will occur during loss of RF transmission of the sensors.

  6. Continuous Glucose Monitoring Systems: A Review

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2013-10-01

    Full Text Available There have been continuous advances in the field of glucose monitoring during the last four decades, which have led to the development of highly evolved blood glucose meters, non-invasive glucose monitoring (NGM devices and continuous glucose monitoring systems (CGMS. Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complications. CGMS have led to tremendous improvements in diabetic management, as shown by the significant lowering of glycated hemoglobin (HbA1c in adults with type I diabetes. Most of the CGMS have been minimally-invasive, although the more recent ones are based on NGM techniques. This manuscript reviews the advances in CGMS for diabetes management along with the future prospects and the challenges involved.

  7. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  8. Top 10 Threats to Computer Systems Include Professors and Students

    Science.gov (United States)

    Young, Jeffrey R.

    2008-01-01

    User awareness is growing in importance when it comes to computer security. Not long ago, keeping college networks safe from cyberattackers mainly involved making sure computers around campus had the latest software patches. New computer worms or viruses would pop up, taking advantage of some digital hole in the Windows operating system or in…

  9. Top 10 Threats to Computer Systems Include Professors and Students

    Science.gov (United States)

    Young, Jeffrey R.

    2008-01-01

    User awareness is growing in importance when it comes to computer security. Not long ago, keeping college networks safe from cyberattackers mainly involved making sure computers around campus had the latest software patches. New computer worms or viruses would pop up, taking advantage of some digital hole in the Windows operating system or in…

  10. Design of Wind Turbine Vibration Monitoring System

    Directory of Open Access Journals (Sweden)

    Shoubin Wang

    2013-04-01

    Full Text Available In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed. In this paper, it analyses the enlargement of all the parts of the structure and the working mechanism, the research method of wind turbine operation vibration is introduced, with the focus being the use of the sensor principle. Finally the hardware design and software of this system is introduced and the main function of this system is described, which realizes condition monitoring of the work state of wind turbines.

  11. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  12. Method and apparatus for smart battery charging including a plurality of controllers each monitoring input variables

    Science.gov (United States)

    Hammerstrom, Donald J.

    2013-10-15

    A method for managing the charging and discharging of batteries wherein at least one battery is connected to a battery charger, the battery charger is connected to a power supply. A plurality of controllers in communication with one and another are provided, each of the controllers monitoring a subset of input variables. A set of charging constraints may then generated for each controller as a function of the subset of input variables. A set of objectives for each controller may also be generated. A preferred charge rate for each controller is generated as a function of either the set of objectives, the charging constraints, or both, using an algorithm that accounts for each of the preferred charge rates for each of the controllers and/or that does not violate any of the charging constraints. A current flow between the battery and the battery charger is then provided at the actual charge rate.

  13. 76 FR 12648 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Science.gov (United States)

    2011-03-08

    .... (2) Electronic mail: zzMSHA-comments@dol.gov . Include ``RIN 1219- AB64'' in the subject line of the message. (3) Facsimile: 202-693-9441. Include ``RIN 1219-AB64'' in the subject line of the message. (4... on appropriate timeframes to switch out sampling devices, Coal Mine Dust Personal Sampler...

  14. Biofilms from a Brazilian water distribution system include filamentous fungi.

    Science.gov (United States)

    Siqueira, V M; Oliveira, H M B; Santos, C; Paterson, R R M; Gusmão, N B; Lima, N

    2013-03-01

    Filamentous fungi in drinking water can block water pipes, can cause organoleptic biodeterioration, and are a source of pathogens. There are increasing reports of the involvement of the organisms in biofilms. This present study describes a sampling device that can be inserted directly into pipes within water distribution systems, allowing biofilm formation in situ. Calcofluor White M2R staining and fluorescent in situ hybridization with morphological analyses using epifluorescent microscopy were used to analyse biofilms for filamentous fungi, permitting direct observation of the fungi. DAPI (4',6-diamidino-2-phenylindole) was applied to detect bacteria. Filamentous fungi were detected in biofilms after 6 months on coupons exposed to raw water, decanted water and at the entrance of the water distribution system. Algae, yeast, and bacteria were also observed. The role of filamentous fungi requires further investigations.

  15. Two stage sorption type cryogenic refrigerator including heat regeneration system

    Science.gov (United States)

    Jones, Jack A.; Wen, Liang-Chi; Bard, Steven

    1989-01-01

    A lower stage chemisorption refrigeration system physically and functionally coupled to an upper stage physical adsorption refrigeration system is disclosed. Waste heat generated by the lower stage cycle is regenerated to fuel the upper stage cycle thereby greatly improving the energy efficiency of a two-stage sorption refrigerator. The two stages are joined by disposing a first pressurization chamber providing a high pressure flow of a first refrigerant for the lower stage refrigeration cycle within a second pressurization chamber providing a high pressure flow of a second refrigerant for the upper stage refrigeration cycle. The first pressurization chamber is separated from the second pressurization chamber by a gas-gap thermal switch which at times is filled with a thermoconductive fluid to allow conduction of heat from the first pressurization chamber to the second pressurization chamber.

  16. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  17. Wireless remote monitoring system for sleep apnea

    Science.gov (United States)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2011-04-01

    Sleep plays the important role of rejuvenating the body, especially the central nervous system. However, more than thirty million people suffer from sleep disorders and sleep deprivation. That can cause serious health consequences by increasing the risk of hypertension, diabetes, heart attack and so on. Apart from the physical health risk, sleep disorders can lead to social problems when sleep disorders are not diagnosed and treated. Currently, sleep disorders are diagnosed through sleep study in a sleep laboratory overnight. This involves large expenses in addition to the inconvenience of overnight hospitalization and disruption of daily life activities. Although some systems provide home based diagnosis, most of systems record the sleep data in a memory card, the patient has to face the inconvenience of sending the memory card to a doctor for diagnosis. To solve the problem, we propose a wireless sensor system for sleep apnea, which enables remote monitoring while the patient is at home. The system has 5 channels to measure ECG, Nasal airflow, body position, abdominal/chest efforts and oxygen saturation. A wireless transmitter unit transmits signals with Zigbee and a receiver unit which has two RF modules, Zigbee and Wi-Fi, receives signals from the transmitter unit and retransmits signals to the remote monitoring system with Zigbee and Wi-Fi, respectively. By using both Zigbee and Wi-Fi, the wireless sensor system can achieve a low power consumption and wide range coverage. The system's features are presented, as well as continuous monitoring results of vital signals.

  18. Advanced 3D Sensing and Visualization System for Unattended Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, J.J.; Little, C.Q.; Nelson, C.L.

    1999-01-01

    The purpose of this project was to create a reliable, 3D sensing and visualization system for unattended monitoring. The system provides benefits for several of Sandia's initiatives including nonproliferation, treaty verification, national security and critical infrastructure surety. The robust qualities of the system make it suitable for both interior and exterior monitoring applications. The 3D sensing system combines two existing sensor technologies in a new way to continuously maintain accurate 3D models of both static and dynamic components of monitored areas (e.g., portions of buildings, roads, and secured perimeters in addition to real-time estimates of the shape, location, and motion of humans and moving objects). A key strength of this system is the ability to monitor simultaneous activities on a continuous basis, such as several humans working independently within a controlled workspace, while also detecting unauthorized entry into the workspace. Data from the sensing system is used to identi~ activities or conditions that can signi~ potential surety (safety, security, and reliability) threats. The system could alert a security operator of potential threats or could be used to cue other detection, inspection or warning systems. An interactive, Web-based, 3D visualization capability was also developed using the Virtual Reality Modeling Language (VRML). The intex%ace allows remote, interactive inspection of a monitored area (via the Internet or Satellite Links) using a 3D computer model of the area that is rendered from actual sensor data.

  19. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. (Institute for Energy Technology (IFE) (Norway))

    2009-07-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  20. Monitoring of the Crab Nebula with Chandra and Other Observatories Including HST

    Science.gov (United States)

    Weisskopf, Martin C.

    2014-01-01

    Subsequent to the detections AGILE and Fermi/LAT of the gamma-ray flares from the Crab Nebula in the fall of 2010, this team has been monitoring the X-Ray emission from the Crab on a regular basis. X-Ray observations have taken place typically once per month when viewing constraints allow and more recently four times per year. There have been notable exceptions, e.g. in April of 2011 and March 2013 when we initiated a set of Chandra Target of opportunity observations in conjunction with bright gamma-ray flares. For much of the time regular HST observations were made in conjunction with the Chandra observations. The aim of this program to further characterize, in depth, the X-Ray and optical variations that take place in the nebula, and by so doing determine the regions which contribute to the harder X-ray variations and, if possible, determine the precise location within the Nebula of the origin of the gamma-ray flares. As part of this project members of the team have developed Singular Value Decomposition techniques to sequences of images in order to more accurately characterize features. The current status of the project will be presented highlighting studies of the inner knot and possible correlations with the flares.

  1. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  2. Design Optimization of Structural Health Monitoring Systems

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, Eric B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-03-06

    Sensor networks drive decisions. Approach: Design networks to minimize the expected total cost (in a statistical sense, i.e. Bayes Risk) associated with making wrong decisions and with installing maintaining and running the sensor network itself. Search for optimal solutions using Monte-Carlo-Sampling-Adapted Genetic Algorithm. Applications include structural health monitoring and surveillance.

  3. Harassment Monitoring System Using Android Smartphone

    Directory of Open Access Journals (Sweden)

    Shivu Gururaj, Dr. Raj Shekhar M Pati

    2013-09-01

    Full Text Available In this paper we propose a system for monitoring harassment. It is essentially software installed on phone which informs the security (e.g. police and dear ones (e.g. parents with location details and seeking for help message. It posts the same details on server to notify public for help.

  4. DIADEM: a system for collaborative environmental monitoring

    NARCIS (Netherlands)

    Winterboer, A.; Martens, M.A.; Pavlin, G.; Groen, F.C.A.; Evers, V.

    2011-01-01

    Environmental monitoring and emergency response projects in urban-industrial areas increasingly rely on efficient collaboration between experts in control rooms and at incident locations, and citizens who live or work in the area. In the video accompanying this abstract we present a system that uses

  5. A hand-hygiene behaviour monitoring system

    NARCIS (Netherlands)

    Van Schie, M.; Wiesman, R.F.F.

    2008-01-01

    The invention relates to a hand-hygiene behaviour monitoring system, comprising: means for detecting the occurrence of an event specified in a hand-hygiene rule, wherein the event involves a person; means for updating behaviour data that is related to acts according to the hand-hygiene rule, wherein

  6. Energy monitoring and control Systems - which one

    Energy Technology Data Exchange (ETDEWEB)

    Agase, H.D.

    1980-01-01

    Considering the high cost and general limitations of energy supplies, there is no better source of energy than simple conservation. It is the cheapest, the safest and the most productive alternative available today. This overview of Energy Monitoring and Control System types, and what to consider in their selection, will relate to conservation and significant dollar savings potential to the user.

  7. Mobile Patient Monitoring: The Mobihealth System

    NARCIS (Netherlands)

    Halteren, van Aart; Bults, Richard; Wac, Katarzyna; Konstantas, Dimitri; Widya, Ing; Dokovski, Nikolay; Koprinkov, George; Jones, Val; Herzog, Rainer

    2004-01-01

    The forthcoming wide availability of high bandwidth public wireless networks will give rise to new mobile healthcare services. To this end, the MobiHealth project has developed and trialed a highly customisable vital signs monitoring system based on a body area network (BAN) and a mobile-health (m-h

  8. Locomotive monitoring system using wireless sensor networks

    CSIR Research Space (South Africa)

    Croucamp, PL

    2014-07-01

    Full Text Available Theft of cables used for powering a locomotive not only stops the train from functioning but also paralyzes the signalling and monitoring system. This means that information on certain locomotive's cannot be passed onto other locomotives which may...

  9. 21 CFR 876.1725 - Gastrointestinal motility monitoring system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and...

  10. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Cortes-Gonzalez, Arely; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two photomultiplier in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator based readout system. Combined information from all systems allows to monitor and equalise the calorimeter r...

  11. Universal chitosan-assisted synthesis of Ag-including heterostructured nanocrystals for label-free in situ SERS monitoring.

    Science.gov (United States)

    Cai, Kai; Xiao, Xiaoyan; Zhang, Huan; Lu, Zhicheng; Liu, Jiawei; Li, Qin; Liu, Chen; Foda, Mohamed F; Han, Heyou

    2015-12-07

    A universal chitosan-assisted method was developed to synthesize various Ag-including heterostructured nanocrystals, in which chelation probably plays a vital role. The as-prepared Ag/Pd heterostructured nanocrystals show outstanding properties when used as bifunctional nanocomposites in label-free in situ SERS monitoring of Pd-catalyzed reaction.

  12. Condition Indicators for Gearbox Condition Monitoring Systems

    OpenAIRE

    P. Večeř; M. Kreidl; R. Šmíd

    2005-01-01

    Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs) are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical ge...

  13. Condition Indicators for Gearbox Condition Monitoring Systems

    Directory of Open Access Journals (Sweden)

    P. Večeř

    2005-01-01

    Full Text Available Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical gears. 

  14. IMPLEMENTATION PAPER ON REAL ESTATE MONITORING SYSTEM

    OpenAIRE

    Sunidhi Kabra*, Vivek Mishra, Kshitiz Kesharwani, Shivaanshu Nagarkar

    2016-01-01

    With the enhancements in the Internet and computer technology, we are now able to do most of our work automatically, for example, e-wallet, online payments, etc. As a whole, Internet has made our lives simpler. Making use of modern day Internet and computer technologies, we have come up with an online system useful in the field of construction. Our concept, Real Estate Monitoring System, enables any individual constructor to automate the manual logs maintained at a construction site. By this ...

  15. Optical monitoring system for a turbine engine

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, Dennis H; Smed, Jan P; Williams, James P; Jonnalagadda, Vinay

    2013-05-14

    The monitoring system for a gas turbine engine including a viewing tube assembly having an inner end and an outer end. The inner end is located adjacent to a hot gas flow path within the gas turbine engine and the outer end is located adjacent to an outer casing of the gas turbine engine. An aperture wall is located at the inner end of the viewing tube assembly and an optical element is located within the viewing tube assembly adjacent to the inner end and is spaced from the aperture wall to define a cooling and purge chamber therebetween. An aperture is defined in the aperture wall for passage of light from the hot gas flow path to the optical element. Swirl passages are defined in the viewing tube assembly between the aperture wall and the optical element for passage of cooling air from a location outside the viewing tube assembly into the chamber, wherein swirl passages effect a swirling movement of air in a circumferential direction within the chamber.

  16. Advanced Risk Management and Monitoring System, ARMMS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kil Yoo; Han, Sang Hoon; Lim, Ho Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Many risk informed regulation and applications (RIR and A) are approved and used for the nuclear power plants(NPPs), and more RIR and A will be actively applied in Korea. Also, since Korean NPPs are recently exported to other country such as UAE, RIR and A would be applied to the exported NPPs. Thus, a tool which will help the user apply RIR and A is required. KAERI is being developing a tool, called ARMMS (Advanced Risk Management and Monitoring System), for this purpose. The design plan of ARMMS was introduced in the Ref, and in this paper, the actual implementation of ARMMS is introduced, and the performance monitoring module is introduced

  17. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  18. Web based remote monitoring and controlling system for vulnerable environments

    Science.gov (United States)

    Thomas, Aparna; George, Minu

    2016-03-01

    The two major areas of concern in industrial establishments are monitoring and security. The remote monitoring and controlling can be established with the help of Web technology. Managers can monitor and control the equipment in the remote area through a web browser. The targeted area includes all type of susceptible environment like gas filling station, research and development laboratories. The environmental parameters like temperature, light intensity, gas etc. can be monitored. Security is a very important factor in an industrial setup. So motion detection feature is added to the system to ensure the security. The remote monitoring and controlling system makes use of the latest, less power consumptive and fast working microcontroller like S3C2440. This system is based on ARM9 and Linux operating system. The ARM9 will collect the sensor data and establish real time video monitoring along with motion detection feature. These captured video data as well as environmental data is transmitted over internet using embedded web server which is integrated within the ARM9 board.

  19. Embedded programmable blood pressure monitoring system

    Science.gov (United States)

    Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk

    2010-02-01

    A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.

  20. Model-based health monitoring of hybrid systems

    CERN Document Server

    Wang, Danwei; Low, Chang Boon; Arogeti, Shai

    2013-01-01

    Offers in-depth comprehensive study on health monitoring for hybrid systems Includes new concepts, such as GARR, mode tracking and multiple failure prognosis Contains many examples, making the developed techniques easily understandable and accessible Introduces state-of-the-art algorithms and methodologies from experienced researchers

  1. System for monitoring microclimate conditions in greenhouse

    Directory of Open Access Journals (Sweden)

    Marković Dušan B.

    2014-01-01

    Full Text Available Monitoring microclimate parameters in different kind of environments has significant contribution to many areas of human activity and production processes. One of them is vegetable production in greenhouses where measurement of its microclimate parameters may influence the decision on taking appropriate action and protect crops. It is also important to preserve optimal condition in greenhouses to facilitate the process of transpiration, plant mineral nutrition and prevent of a variety physiological damage caused by a deficit of some specific nutrients. Systems for monitoring have wide application in the last years thanks to development of modern computer technology. In this paper model of the monitoring system based on smart transducer concept was introduced. Within the system components are based on MSP430 ultra low power micro controllers. They are using wireless communication to exchange data within the system that was structured according to smart transducer concept. User applications from the network could access to system interface using HTTP protocol where web server could be running on the computer or it could be an embedded web server running on micro controller based device.

  2. Integrity monitoring in WLAN positioning systems

    Science.gov (United States)

    Yerubandi, Sri Phani; Kalgikar, Bhargav; Gunturu, Maheedhar; Akopian, David; Chen, Philip

    2009-05-01

    Indoor Positioning Systems using WLANs have become very popular in recent years. These systems are spawning a new class of applications like activity recognition, surveillance, context aware computing and location based services. While Global Positioning System (GPS) is the natural choice for providing navigation in outdoor environment, the urban environment places a significant challenge for positioning using GPS. The GPS signals can be significantly attenuated, and often completely blocked, inside buildings or in urban canyons. As the performance of GPS in indoor environments is not satisfactory, indoor positioning systems based on location fingerprinting of WLANs is being suggested as a viable alternative. The Indoor WLAN Positioning Systems suffer from several phenomena. One of the problems is the continual availability of access points, which directly affects the positioning accuracy. Integrity monitoring of WLAN localization, which computes WLAN positioning with different sets of access points is proposed as a solution for this problem. The positioning accuracy will be adequate for the sets which do not contain faulty or the access points which are offline, while the sets with such access points will fail and they will report random and inaccurate results. The proposed method identifies proper sets and identifies the rogue access points using prediction trajectories. The combination of prediction and correct access point set selection provides a more accurate result. This paper discusses about integrity monitoring method for WLAN devices and followed by how it monitors and developing the application on mobile platforms.

  3. A design methodology for unattended monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    SMITH,JAMES D.; DELAND,SHARON M.

    2000-03-01

    The authors presented a high-level methodology for the design of unattended monitoring systems, focusing on a system to detect diversion of nuclear materials from a storage facility. The methodology is composed of seven, interrelated analyses: Facility Analysis, Vulnerability Analysis, Threat Assessment, Scenario Assessment, Design Analysis, Conceptual Design, and Performance Assessment. The design of the monitoring system is iteratively improved until it meets a set of pre-established performance criteria. The methodology presented here is based on other, well-established system analysis methodologies and hence they believe it can be adapted to other verification or compliance applications. In order to make this approach more generic, however, there needs to be more work on techniques for establishing evaluation criteria and associated performance metrics. They found that defining general-purpose evaluation criteria for verifying compliance with international agreements was a significant undertaking in itself. They finally focused on diversion of nuclear material in order to simplify the problem so that they could work out an overall approach for the design methodology. However, general guidelines for the development of evaluation criteria are critical for a general-purpose methodology. A poor choice in evaluation criteria could result in a monitoring system design that solves the wrong problem.

  4. The environmental radiation monitoring system in Spain

    Directory of Open Access Journals (Sweden)

    Rosario Salas Collantes

    2010-12-01

    Full Text Available The system of environmental radiation monitoring established in Spain is composed of several networks with different objectives, a monitoring network in the vicinity of the facilities and several national networks financed and managed by public agencies. The operators of the facilities are responsible for the conduct of its Environmental Radiological Surveillance Program as directed by the CSN. Moreover, the Directorate General of Civil Defense and Emergencies has a Radioactivity Warning Network (RAR consisting of over 900 automatic stations measuring dose rate distributed nationwide. The Environmental Radioactivity Monitoring Network (Revira, managed by the CSN, is a nationwide network, consists of a Network of Sampling Stations (REM and a Network of Automatic Stations for continuous monitoring (REA. The autonomous communities of Valencia, Catalonia, Extremadura and the Basque Country have their own automated networks similar to that of the CSN. Revira provides information on the radioactivity in the air, soil, water (drinking, inland and sea and of food. The sampling and analysis programs are tailored to radiological recommendations laid down in the European Union Commission. The REM has the collaboration of laboratories in universities and the Centre for Energy, Environmental and Technological Research (CIEMAT for execution. The monitoring of inland and coastal waters is undertaken by the Centre for Studies and Experimentation of Public Works, Ministry of Public Works (CEDEX.

  5. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  6. Deploying Server-side File System Monitoring at NERSC

    Energy Technology Data Exchange (ETDEWEB)

    Uselton, Andrew

    2009-05-01

    The Franklin Cray XT4 at the NERSC center was equipped with the server-side I/O monitoring infrastructure Cerebro/LMT, which is described here in detail. Insights gained from the data produced include a better understanding of instantaneous data rates during file system testing, file system behavior during regular production time, and long-term average behaviors. Information and insights gleaned from this monitoring support efforts to proactively manage the I/O infrastructure on Franklin. A simple model for I/O transactions is introduced and compared with the 250 million observations sent to the LMT database from August 2008 to February 2009.

  7. 40 CFR 265.91 - Ground-water monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  8. Launch Pad 39 Hail Monitor Array System

    Science.gov (United States)

    2008-01-01

    Weather conditions at Kennedy Space Center are extremely dynamic, and they greatly affect the safety of the Space Shuttles sitting on the launch pads. For example, on May 13, 1999, the foam on the External Tank (ET) of STS-96 was significantly damaged by hail at the launch pad, requiring rollback to the Vehicle Assembly Building. The loss of ET foam on STS-114 in 2005 intensified interest in monitoring and measuring damage to ET foam, especially from hail. But hail can be difficult to detect and monitor because it is often localized and obscured by heavy rain. Furthermore, the hot Florida climate usually melts the hail even before the rainfall subsides. In response, the hail monitor array (HMA) system, a joint effort of the Applied Physics Laboratory operated by NASA and ASRC Aerospace at KSC, was deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow (CoCoRaHS) network, in conjunction with Colorado State University, continue to test duplicate hail monitor systems deployed in the high plains of Colorado.

  9. Fermilab accelerator control system: Analog monitoring facilities

    Energy Technology Data Exchange (ETDEWEB)

    Seino, K.; Anderson, L.; Smedinghoff, J.

    1987-10-01

    Thousands of analog signals are monitored in different areas of the Fermilab accelerator complex. For general purposes, analog signals are sent over coaxial or twinaxial cables with varying lengths, collected at fan-in boxes and digitized with 12 bit multiplexed ADCs. For higher resolution requirements, analog signals are digitized at sources and are serially sent to the control system. This paper surveys ADC subsystems that are used with the accelerator control systems and discusses practical problems and solutions, and it describes how analog data are presented on the console system.

  10. Wearable system for vital signs monitoring.

    Science.gov (United States)

    Paradiso, Rita; Loriga, Gianni; Taccini, Nicola

    2004-01-01

    A new concept in healthcare, aimed at providing continuous remote monitoring of user's vital signs, is emerging. An innovative system named WEALTHY is presented, where conducting and piezoresistive materials in the form of fiber and yarn are integrated and used as sensor and electrode elements. The simultaneous recording of vital signs allows parameter extrapolation and inter-signal elaboration that contribute to producing alert messages and synoptic patient tables. Cardiac patients in the rehabilitation phase can be continuously monitored during selected time intervals, such as during physical activity or occurrence of symptoms, to discover potential threats and generate appropriate alerts to the patient and/or to an emergency center. The core of the system sensing is a textile interface, in which the sensing components are elements of the fabric: the sensorized garment is comfortable like a common article of clothing and is made with knitting machines; furthermore, the position of the electrodes and sensors is fixed and the elasticity of the fabric allows a good fitting to the body. The system is provided with a portable electronic unit, where signals are acquired, elaborated and transmitted. A monitoring system allows extrapolation of a new physiological index and data flow coordination as well as alarm management and database creation.

  11. Valve Health Monitoring System Utilizing Smart Instrumentation

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  12. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  13. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  14. Production monitoring system for understanding product robustness

    DEFF Research Database (Denmark)

    Boorla, Srinivasa Murthy; Howard, Thomas J.

    2016-01-01

    In the current quality paradigm, the performance of a product is kept within specification by ensuring that its parts are within specification. Product performance is then validated after final assembly. However, this does not control how robust the product performance is, i.e. how much...... it will vary between the specification limits. In this paper, a model for predicting product performance is proposed, taking into account design, assembly and process parameters live from production. This empowers production to maintain final product performance, instead of part quality. The PRECI‐IN case...... study is used to demonstrate how the monitoring system can be used to efficiently guide corrective action to improve product performance. It is claimed that the monitoring system can be used to dramatically cut the time taken to identify, planand execute corrective action related to typical quality...

  15. A remote drip infusion monitoring system employing Bluetooth.

    Science.gov (United States)

    Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton

    2012-01-01

    We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.

  16. Wireless system for seismic activity monitoring

    OpenAIRE

    Безвесільна, Олена Миколаївна; Козько, Констянтин Сергійович

    2014-01-01

    The article examines the concepts and principles of sensor networks operations, especially the one that is used to monitor seismic activity and potential natural disasters. It also describes the operating principle of the geographically distributed wireless system, represented by block diagrams of typical sensor nodes and base station, as well as constructive electrical circuit sensor node and the frequency generator radio transmissions the base station and sensor nodes, we formulate to calcu...

  17. 30 CFR 77.312 - Fail safe monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related...

  18. Design of multi-function Hanford tank corrosion monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    EDGEMON, G.L.

    1999-04-01

    A multi-fiction corrosion monitoring system has been designed for installation into DST 241-AN-105 at the Hanford Site in fiscal year 1999. The 241-AN-105 system is the third-generation corrosion monitoring system described by TTP RLO-8-WT-21. Improvements and upgrades from the second-generation system (installed in 241-AN-102) that have been incorporated into the third-generation system include: Gasket seating surfaces utilize O-rings instead of a washer type gasket for improved seal; Probe design contains an equally spaced array of 22 thermocouples; Probe design contains an adjustable verification thermocouple; Probe design contains three ports for pressure/gas sampling; Probe design contains one set of strain gauges to monitor probe flexure if flexure occurs; Probe utilizes an adjustable collar to allow depth adjustment of probe during installation; System is capable of periodically conducting LPR scans; System is housed in a climate controlled enclosure adjacent to the riser containing the probe; System uses wireless Ethernet links to send data to Hanford Local Area Network; System uses commercial remote access software to allow remote command and control; and Above ground wiring uses driven shields to reduce external electrostatic noise in the data. These new design features have transformed what was primarily a second-generation corrosion monitoring system into a multi-function tank monitoring system that adds a great deal of functionality to the probe, provides for a better understanding of the relationship between corrosion and other tank operating parameters, and optimizes the use of the riser that houses the probe in the tank.

  19. An optically remote powered subsea video monitoring system

    Science.gov (United States)

    Lau, Fat Kit; Stewart, Brian; McStay, Danny

    2012-06-01

    The drive for Ocean pollution prevention requires a significant increase in the extent and type of monitoring of subsea hydrocarbon production equipment. Sensors, instrumentation, control electronics, data logging and transmission units comprising such monitoring systems will all require to be powered. Conventionally electrical powering is supplied by standard subsea electrical cabling. The ability to visualise the assets being monitored and any changes or faults in the equipment is advantageous to an overall monitoring system. However the effective use of video cameras, particularly if the transmission of real time high resolution video is desired, requires a high data rate and low loss communication capability. This can be challenging for heavy and costly electrical cables over extended distances. For this reason optical fibre is often adopted as the communication channel. Using optical fibre cables for both communications and power delivery can also reduce the cost of cabling. In this paper we report a prototype optically remote powered subsea video monitoring system that provides an alternative approach to powering subsea video cameras. The source power is transmitted to the subsea module through optical fibre with an optical-to-electrical converter located in the module. To facilitate intelligent power management in the subsea module, a supercapacitor based intermediate energy storage is installed. Feasibility of the system will be demonstrated. This will include energy charging and camera operation times.

  20. Muscular condition monitoring system using fiber bragg grating sensors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heon Young; Lee, Jin Hyuk; Kim, Dae Hyun [Seoul National University of Technology, Seoul (Korea, Republic of)

    2014-10-15

    Fiber optic sensors (FOS) have advantages such as electromagnetic interference (EMI) immunity, corrosion resistance and multiplexing capability. For these reasons, they are widely used in various condition monitoring systems (CMS). This study investigated a muscular condition monitoring system using fiber optic sensors (FOS). Generally, sensors for monitoring the condition of the human body are based on electro-magnetic devices. However, such an electrical system has several weaknesses, including the potential for electro-magnetic interference and distortion. Fiber Bragg grating (FBG) sensors overcome these weaknesses, along with simplifying the devices and increasing user convenience. To measure the level of muscle contraction and relaxation, which indicates the muscle condition, a belt-shaped FBG sensor module that makes it possible to monitor the movement of muscles in the radial and circumferential directions was fabricated in this study. In addition, a uniaxial tensile test was carried out in order to evaluate the applicability of this FBG sensor module. Based on the experimental results, a relationship was observed between the tensile stress and Bragg wavelength of the FBG sensors, which revealed the possibility of fabricating a muscular condition monitoring system based on FBG sensors.

  1. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  2. Tank monitor and control system (TMACS) software configuration management plan

    Energy Technology Data Exchange (ETDEWEB)

    GLASSCOCK, J.A.

    1999-05-13

    This Software Configuration Management Plan (SCMP) describes the methodology for control of computer software developed and supported by the Systems Development and Integration (SD and I) organization of Lockheed Martin Services, Inc. (LMSI) for the Tank Monitor and Control System (TMACS). This plan controls changes to the software and configuration files used by TMACS. The controlled software includes the Gensym software package, Gensym knowledge base files developed for TMACS, C-language programs used by TMACS, the operating system on the production machine, language compilers, and all Windows NT commands and functions which affect the operating environment. The configuration files controlled include the files downloaded to the Acromag and Westronic field instruments.

  3. Master Console System Monitoring and Control Development

    Science.gov (United States)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the summer of 2013 involved the development of firing room displays and support applications at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I created control scripts using the Application Control Language (ACL) to analyze the health and status of Kennedy Ground Control System (KGCS) programmable logic controllers (PLCs). This application provides a system health and status display I created with summarized data for use by Master Console Operators (MCO) to monitor and verify the integrity of KGCS subsystems.

  4. Research of PD on-line Monitoring System for DC Cable

    Directory of Open Access Journals (Sweden)

    Duan Da-Peng

    2014-01-01

    Full Text Available In order to monitor the insulation of XLPE cable of rail system, an On-line Partial Discharge (PD Monitoring System applied for 1500V DC cables of Shanghai Traction Substation is described, including its hardware and software structure. After installed, this system successfully detected one PD signal. The results demonstrated that this system worked stably and reliably.

  5. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR......), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible......Traditionally corrosion monitoring in district heating systems has been performed offline via weight loss coupons. These measurements give information about the past and not the present situation and require long exposure time (weeks or months). The good quality of district heating medium makes...

  6. A Dynamic and Interactive Monitoring System of Data Center Resources

    Directory of Open Access Journals (Sweden)

    Yu Ling-Fei

    2016-01-01

    Full Text Available To maximize the utilization and effectiveness of resources, it is very necessary to have a well suited management system for modern data centers. Traditional approaches to resource provisioning and service requests have proven to be ill suited for virtualization and cloud computing. The manual handoffs between technology teams were also highly inefficient and poorly documented. In this paper, a dynamic and interactive monitoring system for data center resources, ResourceView, is presented. By consolidating all data center management functionality into a single interface, ResourceView shares a common view of the timeline metric status, while providing comprehensive, centralized monitoring of data center physical and virtual IT assets including power, cooling, physical space and VMs, so that to improve availability and efficiency. In addition, servers and VMs can be monitored from several viewpoints such as clusters, racks and projects, which is very convenient for users.

  7. Run Control and Monitor System for the CMS Experiment

    CERN Document Server

    Bellato, M; Brigljevic, V; Bruno, G; Cano, E; Cittolin, Sergio; Csilling, Akos; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutleber, J; Jacobs, C; Kozlovszky, Miklos; Larsen, H; Magrans de Abril, Ildefons; Maron, G; Meijers, F; Meschi, E; Murray, S; Oh, A; Orsini, L; Pollet, L; Rácz, A; Rorato, G; Samyn, D; Scharff-Hansen, P; Schwick, C; Sphicas, Paris; Toniolo, N; Ventura, Sandro; Zangrando, L

    2003-01-01

    The Run Control and Monitor System (RCMS) of the CMS experiment is the set of hardware and software components responsible for controlling and monitoring the experiment during data-taking. It provides users with a "virtual counting room", enabling them to operate the experiment and to monitor detector status and data quality from any point in the world. This paper describes the architecture of the RCMS with particular emphasis on its scalability through a distributed collection of nodes arranged in a tree-based hierarchy. The current implementation of the architecture in a prototype RCMS used in test beam setups, detector validations and DAQ demonstrators is documented. A discussion of the key technologies used, including Web Services, and the results of tests performed with a 128-node system are presented.

  8. Monitoring and Reporting Tools of the International Data Centre and International Monitoring System

    Science.gov (United States)

    Lastowka, L.; Anichenko, A.; Galindo, M.; Villagran Herrera, M.; Mori, S.; Malakhova, M.; Daly, T.; Otsuka, R.; Stangel, H.

    2007-05-01

    The Comprehensive Test-Ban Treaty (CTBT) which prohibits all nuclear explosions was opened for signature in 1996. Since then, the Preparatory Commission for the CTBT Organization has been working towards the establishment of a global verification regime to monitor compliance with the ban on nuclear testing. The International Monitoring System (IMS) comprises facilities for seismic, hydroacoustic, infrasound and radionuclide monitoring, and the means of communication. This system is supported by the International Data Centre (IDC), which provides objective products and services necessary for effective global monitoring. Upon completion of the IMS, 321 stations will be contributing to both near real-time and reviewed data products. Currently there are 194 facilities in IDC operations. This number is expected to increase by about 40% over the next few years, necessitating methods and tools to effectively handle the expansion. The requirements of high data availability as well as operational transparency are fundamental principals of IMS network operations, therefore, a suite of tools for monitoring and reporting have been developed. These include applications for monitoring Global Communication Infrastructure (GCI) links, detecting outages in continuous and segmented data, monitoring the status of data processing and forwarding to member states, and for systematic electronic communication and problem ticketing. The operation of the IMS network requires the help of local specialists whose cooperation is in some cases ensured by contracts or other agreements. The PTS (Provisional Technical Secretariat) strives to make the monitoring of the IMS as standardized and efficient as possible, and has therefore created the Operations Centre in which the use of most the tools are centralized. Recently the tasks of operations across all technologies, including the GCI, have been centralized within a single section of the organization. To harmonize the operations, an ongoing State

  9. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  10. SEMS: System for Environmental Monitoring and Sustainability

    Science.gov (United States)

    Arvidson, Raymond E.

    1998-01-01

    The goal of this project was to establish a computational and data management system, SEMS, building on our existing system and MTPE-related research. We proposed that the new system would help support Washington University's efforts in environmental sustainability through use in: (a) Problem-based environmental curriculum for freshmen and sophomores funded by the Hewlett Foundation that integrates scientific, cultural, and policy perspectives to understand the dynamics of wetland degradation, deforestation, and desertification and that will develop policies for sustainable environments and economies; (b) Higher-level undergraduate and graduate courses focused on monitoring the environment and developing policies that will lead to sustainable environmental and economic conditions; and (c) Interdisciplinary research focused on the dynamics of the Missouri River system and development of policies that lead to sustainable environmental and economic floodplain conditions.

  11. Radiation portal monitor system and method

    Science.gov (United States)

    Morris, Christopher; Borozdin, Konstantin N.; Green, J. Andrew; Hogan, Gary E.; Makela, Mark F.; Priedhorsky, William C.; Saunders, Alexander; Schultz, Larry J.; Sossong, Michael J.

    2009-12-15

    A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  12. A novel electric power quality monitoring system for transient analysis

    OpenAIRE

    2014-01-01

    Electricity is vital for our daily life in modern cites. In order to ensure its reliability and supply, an electric power monitoring system is indispensable in an electric power system. Currently, most electric power monitoring systems are designed for steady-state monitoring only. They may not be able to monitor instantaneous power disturbances, such as voltage surge, happened in electric power systems. In fact, instantaneous power disturbances are frequently found in electric power systems,...

  13. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, Tjeerd; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with deve

  14. FREQUENCY OPTIMIZATION FOR SECURITY MONITORING OF COMPUTER SYSTEMS

    Directory of Open Access Journals (Sweden)

    Вogatyrev V.A.

    2015-03-01

    Full Text Available The subject areas of the proposed research are monitoring facilities for protection of computer systems exposed to destructive attacks of accidental and malicious nature. The interval optimization model of test monitoring for the detection of hazardous states of security breach caused by destructive attacks is proposed. Optimization function is to maximize profit in case of requests servicing in conditions of uncertainty, and intensity variance of the destructive attacks including penalties when servicing of requests is in dangerous conditions. The vector task of system availability maximization and minimization of probabilities for its downtime and dangerous conditions is proposed to be reduced to the scalar optimization problem based on the criterion of profit maximization from information services (service of requests that integrates these private criteria. Optimization variants are considered with the definition of the averaged periodic activities of monitoring and adapting of these periods to the changes in the intensity of destructive attacks. Adaptation efficiency of the monitoring frequency to changes in the activity of the destructive attacks is shown. The proposed solutions can find their application for optimization of test monitoring intervals to detect hazardous conditions of security breach that makes it possible to increase the system effectiveness, and specifically, to maximize the expected profit from information services.

  15. Mobile monitoring and embedded control system for factory environment.

    Science.gov (United States)

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  16. Mobile Monitoring and Embedded Control System for Factory Environment

    Directory of Open Access Journals (Sweden)

    Kuang-Yow Lian

    2013-12-01

    Full Text Available This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC technology is used to carry out the actual electricity load experiments using smart phones.

  17. Process monitoring using ultrasonic sensor systems.

    Science.gov (United States)

    Henning, Bernd; Rautenberg, Jens

    2006-12-22

    Continuous in-line measurement of substance concentration in liquid mixtures is valuable in improving industrial processes in terms of material properties, energy efficiency and process safety. Ultrasonic sensor systems meet the practical requirements of a chemical sensor quite well. Currently ultrasonic sensor systems are widely used as acoustic chemical sensors to measure concentration of selected substances or to monitor the course of polymerisation, crystallisation or fermentation processes. Useable acoustic properties for the characterisation of liquid mixtures are sound velocity, sound absorption and acoustic impedance. This contribution will give a short overview of the state of the art and several trends for the use of ultrasonic sensor systems in process applications. Novel investigations show the very promising possibility to analyse liquid multi-phase mixtures like suspensions, emulsions and dispersions.

  18. Smart Garbage Monitoring System for Waste Management

    Directory of Open Access Journals (Sweden)

    Mohd Yusof Norfadzlia

    2017-01-01

    Full Text Available Piles of rubbish are one of the major problems faced by most people in Malaysia, especially those who live in flats, as the number of bins is limited and shared among all residents. It may cause pollutions, which may lead to sanitary issues and diseases. This project presents the development of a smart garbage monitoring system in order to measure waste level in the garbage bin in real-time and to alert the municipality, in particular cases, via SMS. The proposed system is consisted by the ultrasonic sensor to measure the waste level, the GSM module to send the SMS, and an Arduino Uno which controls the system operation. It supposes to generate and send the warning messages to the municipality via SMS when the waste bin is full or almost full, so the garbage can be collected immediately. Furthermore, it is expected to contribute to improving the efficiency of the solid waste disposal management.

  19. Automatic outdoor monitoring system for photovoltaic panels

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  20. Monitoring the LHCb data quality system

    CERN Multimedia

    Baranov, Alexander

    2016-01-01

    Monitoring the quality of the data, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the apparatus during the data taking. DQM at LHCb is carried out in two phase. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs with some delay. For the Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator's task, Monet is also equipped with an automated, fully configurable, alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation.

  1. Automatic outdoor monitoring system for photovoltaic panels.

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  2. Prometheus: a next-generation monitoring system

    CERN Document Server

    CERN. Geneva

    2017-01-01

    Prometheus is an open eco-system that provides an end-to-end approach to infrastructure and application monitoring. It covers all levels beginning with easy instrumentation based on a flexible, multi-dimensional data model. The Prometheus server itself collects and stores time series while trying to maintain operational simplicity while being adaptable to varying scales and layouts of infrastructure. By integrating with a wide range of service discovery systems, it always stays in sync with the world it is monitoring. The powerful query language allows us to ask complex questions and can be applied seamlessly between ad-hoc investigation and static dashboarding. It is also directly applied in the eco-system's alerting layer, which favors a time-series based over and event driven approach. In this talk we will look at all aspects of Prometheus from the high-level philosophy behind its design to its practical concerns of implementation and operation. About the speaker Fabian Reinartz is a software eng...

  3. Automatic outdoor monitoring system for photovoltaic panels

    Energy Technology Data Exchange (ETDEWEB)

    Stefancich, Marco [Consiglio Nazionale delle Ricerce, Istituto dei Materiali per l’Elettronica ed il Magnetismo (CNR-IMEM), Parco Area delle Scienze 37/A, 43124 Parma, Italy; Simpson, Lin [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA; Chiesa, Matteo [Masdar Institute of Science and Technology, P.O. Box 54224, Masdar City, Abu Dhabi, United Arab Emirates

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  4. Mobile health-monitoring system through visible light communication.

    Science.gov (United States)

    Tan, Yee-Yong; Chung, Wan-Young

    2014-01-01

    Promising development in the light emitting diode (LED) technology has spurred the interest to adapt LED for both illumination and data transmission. This has fostered the growth of interest in visible light communication (VLC), with on-going research to utilize VLC in various applications. This paper presents a mobile-health monitoring system, where healthcare information such as biomedical signals and patient information are transmitted via the LED lighting. A small and portable receiver module is designed and developed to be attached to the mobile device, providing a seamless monitoring environment. Three different healthcare information including ECG, PPG signals and HL7 text information is transmitted simultaneously, using a single channel VLC. This allows for a more precise and accurate monitoring and diagnosis. The data packet size is carefully designed, to transmit information in a minimal packet error rate. A comprehensive monitoring application is designed and developed through the use of a tablet computer in our study. Monitoring and evaluation such as heart rate and arterial blood pressure measurement can be performed concurrently. Real-time monitoring is demonstrated through experiment, where non-hazardous transmission method can be implemented alongside a portable device for better and safer healthcare service.

  5. 30 CFR 27.21 - Methane-monitoring system.

    Science.gov (United States)

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane...-monitoring system are functioning normally. (b) A methane-monitoring system shall be rugged in construction so that its operation will not be affected by vibration or physical shock, such as normally...

  6. A Wireless Distributed Condition Monitoring System Based on Bluetooth Technology

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Based on the discussion of bluetooth and network technology, this paper proposed an entire framework of a wireless distributed monitoring system by combining the characteristics of industry application. The feasibility of putting this kind of system in practice is discussed. The wireless distributed monitoring system can enhance the performance of condition monitoring more than the traditional one used now.

  7. Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    Energy Technology Data Exchange (ETDEWEB)

    Fehlau, P.E.; Coop, K.; Garcia, C. Jr.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium. 6 references, 9 figures, 2 tables.

  8. Real-time expert system monitors complex air regs

    Energy Technology Data Exchange (ETDEWEB)

    Hasbach, A.

    1995-07-01

    The South Coast Air Quality Management District (SCAQMD) in southern California monitors NO{sub x} emissions in real time from a total of 60 boilers at the area`s five electric utilities. SCAQMD accomplishes this with an application developed using G2, an expert system from Gensym Corp., Cambridge, Mass., interfaced to monitoring equipment at each remote facility. In 1991, the SCAQMD board passed Rule 1135 requiring monitoring of nitrogen oxide (NO{sub x}) emissions from electric-power generating systems. The rule requires utilities to transmit boiler emissions data in near real-time to SCAQMD. Each utility had to install a continuous emission monitoring system (CEMS) to measure emissions from each boiler and a remote terminal unit (RTU) to telecommunicate emissions data to SCAQMD. The CEMS acquires data from sensing devices for each boiler. The RTU collects the data, performs calculations, and transmits formatted information to the Central Station Compliance Advisory Expert System at SCAQMD. This information includes NO{sub x} emissions, power generation, fuel usage, stack gas flow and equipment status.

  9. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  10. Systems and Sensors for Debris-flow Monitoring and Warning.

    Science.gov (United States)

    Arattano, Massimo; Marchi, Lorenzo

    2008-04-04

    Debris flows are a type of mass movement that occurs in mountain torrents. They consist of a high concentration of solid material in water that flows as a wave with a steep front. Debris flows can be considered a phenomenon intermediate between landslides and water floods. They are amongst the most hazardous natural processes in mountainous regions and may occur under different climatic conditions. Their destructiveness is due to different factors: their capability of transporting and depositing huge amounts of solid materials, which may also reach large sizes (boulders of several cubic meters are commonly transported by debris flows), their steep fronts, which may reach several meters of height and also their high velocities. The implementation of both structural and nonstructural control measures is often required when debris flows endanger routes, urban areas and other infrastructures. Sensor networks for debris-flow monitoring and warning play an important role amongst non-structural measures intended to reduce debris-flow risk. In particular, debris flow warning systems can be subdivided into two main classes: advance warning and event warning systems. These two classes employ different types of sensors. Advance warning systems are based on monitoring causative hydrometeorological processes (typically rainfall) and aim to issue a warning before a possible debris flow is triggered. Event warning systems are based on detecting debris flows when these processes are in progress. They have a much smaller lead time than advance warning ones but are also less prone to false alarms. Advance warning for debris flows employs sensors and techniques typical of meteorology and hydrology, including measuring rainfall by means of rain gauges and weather radar and monitoring water discharge in headwater streams. Event warning systems use different types of sensors, encompassing ultrasonic or radar gauges, ground vibration sensors, videocameras, avalanche pendulums, photocells

  11. Systems and Sensors for Debris-flow Monitoring and Warning

    Directory of Open Access Journals (Sweden)

    Lorenzo Marchi

    2008-04-01

    Full Text Available Debris flows are a type of mass movement that occurs in mountain torrents. They consist of a high concentration of solid material in water that flows as a wave with a steep front. Debris flows can be considered a phenomenon intermediate between landslides and water floods. They are amongst the most hazardous natural processes in mountainous regions and may occur under different climatic conditions. Their destructiveness is due to different factors: their capability of transporting and depositing huge amounts of solid materials, which may also reach large sizes (boulders of several cubic meters are commonly transported by debris flows, their steep fronts, which may reach several meters of height and also their high velocities. The implementation of both structural and nonstructural control measures is often required when debris flows endanger routes, urban areas and other infrastructures. Sensor networks for debris-flow monitoring and warning play an important role amongst non-structural measures intended to reduce debris-flow risk. In particular, debris flow warning systems can be subdivided into two main classes: advance warning and event warning systems. These two classes employ different types of sensors. Advance warning systems are based on monitoring causative hydrometeorological processes (typically rainfall and aim to issue a warning before a possible debris flow is triggered. Event warning systems are based on detecting debris flows when these processes are in progress. They have a much smaller lead time than advance warning ones but are also less prone to false alarms. Advance warning for debris flows employs sensors and techniques typical of meteorology and hydrology, including measuring rainfall by means of rain gauges and weather radar and monitoring water discharge in headwater streams. Event warning systems use different types of sensors, encompassing ultrasonic or radar gauges, ground vibration sensors, videocameras, avalanche

  12. A Spouted Bed Reactor Monitoring System for Particulate Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    D. S. Wendt; R. L. Bewley; W. E. Windes

    2007-06-01

    Conversion and coating of particle nuclear fuel is performed in spouted (fluidized) bed reactors. The reactor must be capable of operating at temperatures up to 2000°C in inert, flammable, and coating gas environments. The spouted bed reactor geometry is defined by a graphite retort with a 2.5 inch inside diameter, conical section with a 60° included angle, and a 4 mm gas inlet orifice diameter through which particles are removed from the reactor at the completion of each run. The particles may range from 200 µm to 2 mm in diameter. Maintaining optimal gas flow rates slightly above the minimum spouting velocity throughout the duration of each run is complicated by the variation of particle size and density as conversion and/or coating reactions proceed in addition to gas composition and temperature variations. In order to achieve uniform particle coating, prevent agglomeration of the particle bed, and monitor the reaction progress, a spouted bed monitoring system was developed. The monitoring system includes a high-sensitivity, low-response time differential pressure transducer paired with a signal processing, data acquisition, and process control unit which allows for real-time monitoring and control of the spouted bed reactor. The pressure transducer is mounted upstream of the spouted bed reactor gas inlet. The gas flow into the reactor induces motion of the particles in the bed and prevents the particles from draining from the reactor due to gravitational forces. Pressure fluctuations in the gas inlet stream are generated as the particles in the bed interact with the entering gas stream. The pressure fluctuations are produced by bulk movement of the bed, generation and movement of gas bubbles through the bed, and the individual motion of particles and particle subsets in the bed. The pressure fluctuations propagate upstream to the pressure transducer where they can be monitored. Pressure fluctuation, mean differential pressure, gas flow rate, reactor

  13. Requirements of CLIC Beam Loss Monitoring System

    CERN Document Server

    Sapinski, M; Holzer, EB; Jonker, M; Mallows, S; Otto, T; Welsch, C

    2010-01-01

    The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

  14. Using simulation to evaluate warhead monitoring system effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, Casey J.; Brigantic, Robert T.; Keating, Douglas H.; Liles, Karina R.; Meyer, Nicholas J.; Oster, Matthew R.; Waterworth, Angela M.

    2015-07-12

    There is a need to develop and demonstrate technical approaches for verifying potential future agreements to limit and reduce total warhead stockpiles. To facilitate this aim, warhead monitoring systems employ both concepts of operations (CONOPS) and technologies. A systems evaluation approach can be used to assess the relative performance of CONOPS and technologies in their ability to achieve monitoring system objectives which include: 1) confidence that a treaty accountable item (TAI) initialized by the monitoring system is as declared; 2) confidence that there is no undetected diversion from the monitoring system; and 3) confidence that a TAI is dismantled as declared. Although there are many quantitative methods that can be used to assess system performance for the above objectives, this paper focuses on a simulation perspective primarily for the ability to support analysis of the probabilities that are used to define operating characteristics of CONOPS and technologies. This paper describes a discrete event simulation (DES) model, comprised of three major sub-models: including TAI lifecycle flow, monitoring activities, and declaration behavior. The DES model seeks to capture all processes and decision points associated with the progressions of virtual TAIs, with notional characteristics, through the monitoring system from initialization through dismantlement. The simulation updates TAI progression (i.e., whether the generated test objects are accepted and rejected at the appropriate points) all the way through dismantlement. Evaluation of TAI lifecycles primarily serves to assess how the order, frequency, and combination of functions in the CONOPS affect system performance as a whole. It is important, however, to note that discrete event simulation is also capable (at a basic level) of addressing vulnerabilities in the CONOPS and interdependencies between individual functions as well. This approach is beneficial because it does not rely on complex mathematical

  15. Integrated active sensor system for real time vibration monitoring.

    Science.gov (United States)

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-11-05

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.

  16. Molecular Imaging System for Monitoring Tumor Angiogenesis

    Science.gov (United States)

    Aytac, Esra; Burcin Unlu, Mehmet

    2012-02-01

    In cancer, non-invasive imaging techniques that monitor molecular processes associated with the tumor angiogenesis could have a central role in the evaluation of novel antiangiogenic and proangiogenic therapies as well as early detection of the disease. Matrix metalloproteinases (MMP) can serve as specific biological targets for imaging of angiogenesis since expression of MMPs is required for angiogenesis and has been found to be upregulated in every type of human cancer and correlates with stage, invasive, metastatic properties and poor prognosis. However, for most cancers it is still unknown when, where and how MMPs are involved in the tumor angiogenesis [1]. Development of high-resolution, high sensitivity imaging techniques in parallel with the tumor models could prove invaluable for assessing the physical location and the time frame of MMP enzymatic acitivity. The goal of this study is to understand where, when and how MMPs are involved in the tumor angiogenesis. We will accomplish this goal by following two objectives: to develop a high sensitivity, high resolution molecular imaging system, to develop a virtual tumor simulator that can predict the physical location and the time frame of the MMP activity. In order to achieve our objectives, we will first develop a PAM system and develop a mathematical tumor model in which the quantitative data obtained from the PAM can be integrated. So, this work will develop a virtual tumor simulator and a molecular imaging system for monitoring tumor angiogenesis. 1.Kessenbrock, K., V. Plaks, and Z. Werb, MMP:regulators of the tumor microenvironment. Cell, 2010. 141(1)

  17. Performance Assessment and Active System Monitoring for Refrigeration Systems

    DEFF Research Database (Denmark)

    Green, Torben

    for algorithms that ensures or improves the performance of the system. A supermarket refrigeration system is usually a complex and distributed control system, and it can therefore be difficult to assess the performance without a formal method. The main interest for a supermarket, with respect...... of the refrigeration system has been addressed in the project. The proposed methods for improvement relies on a minimum of detailed knowledge about the refrigeration system. In addition, since a refrigeration system often operates in steady state an active system monitoring setup has been proposed, to enable...... a method for assessing the operational performance at a plan-wide level and is therefore providing a tool for improving the plant-wide performance. The performance function has been used in dierent setups to improve the performance of the refrigeration system. Static and the dynamic performance...

  18. Wireless Remote Monitoring System for Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Allan HUYNH

    2010-07-01

    Full Text Available Existing systems to collect temperature and relative humidity data at cultural heritage buildings require technical knowledge by people who are working with it, which is very seldom that they do have. The systems available today also require manual downloading of the collected data from the sensor to a computer for central storage and for further analysis. In this paper a wireless remote sensor network based on the ZigBee technology together with a simplified data collection system is presented. The system does not require any knowledge by the building administrator after the network is deployed. The wireless sensor device will automatically join available network when the user wants to expand the network. The collected data will be automatically and periodically synchronized to a remote main server via an Internet connection. The data can be used for centralized monitoring and other purpose. The power consumption of the sensor module is also minimized and the battery lifetime is estimated up to 10 years.

  19. Automated Monitoring System for Waste Disposal Sites and Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    S. E. Rawlinson

    2003-03-01

    A proposal submitted to the U.S. Department of Energy (DOE), Office of Science and Technology, Accelerated Site Technology Deployment (ASTD) program to deploy an automated monitoring system for waste disposal sites and groundwater, herein referred to as the ''Automated Monitoring System,'' was funded in fiscal year (FY) 2002. This two-year project included three parts: (1) deployment of cellular telephone modems on existing dataloggers, (2) development of a data management system, and (3) development of Internet accessibility. The proposed concept was initially (in FY 2002) to deploy cellular telephone modems on existing dataloggers and partially develop the data management system at the Nevada Test Site (NTS). This initial effort included both Bechtel Nevada (BN) and the Desert Research Institute (DRI). The following year (FY 2003), cellular modems were to be similarly deployed at Sandia National Laboratories (SNL) and Los Alamos National Laboratory (LANL), and the early data management system developed at the NTS was to be brought to those locations for site-specific development and use. Also in FY 2003, additional site-specific development of the complete system was to be conducted at the NTS. To complete the project, certain data, depending on site-specific conditions or restrictions involving distribution of data, were to made available through the Internet via the DRI/Western Region Climate Center (WRCC) WEABASE platform. If the complete project had been implemented, the system schematic would have looked like the figure on the following page.

  20. Standard-D hydrogen monitoring system, system design description

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1996-09-26

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS.

  1. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2740 Perinatal monitoring system and accessories. (a) Identification. A...

  2. Database Performance Monitoring for the Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    The Database Performance Monitoring (DPM) software (copyright in processes) is being developed at Sandia National Laboratories to perform quality control analysis on time series data. The software loads time indexed databases (currently csv format), performs a series of quality control tests defined by the user, and creates reports which include summary statistics, tables, and graphics. DPM can be setup to run on an automated schedule defined by the user. For example, the software can be run once per day to analyze data collected on the previous day. HTML formatted reports can be sent via email or hosted on a website. To compare performance of several databases, summary statistics and graphics can be gathered in a dashboard view which links to detailed reporting information for each database. The software can be customized for specific applications.

  3. The Error Monitoring and Processing System in Alcohol Use

    Directory of Open Access Journals (Sweden)

    Menizibeya O. Welcome

    2010-10-01

    Full Text Available Background: Current data suggest that alcohol might play significant role in error commission. Error commission is related to the functions of the Error Monitoring and Processing System (EMPS located in the substantia nigra of the midbrain, basal ganglia and cortex of the forebrain. The main components of the EMPS are the dopaminergic system and anterior cingulate cortex. Although, recent data show that alcohol disrupts the EMPS, the ways in which alcohol affects this system are poorly understood.Aims & Objectives: We reviewed recent data that suggest the indirect effect of alcohol use on error commission.Methods / Study Design: Databases were searched for relevant literatures using the following keywords combination – Alcohol AND Error Commission (OR Processing, Monitoring, Correction, Detection. Literatures were searched in scientific databases (Medline, DOAJ, Embase from 1940 to August 2010, journal website (Psychophysiology, Neuroscience and Trends in Neuroscience. Manual book search, including library information were included in the data collection process. Other additional information was searched through Google.Results / Findings: Blood and brain glucose levels play a vital role in error commission, and are related to error commission, monitoring and processing through the modulation of the activity of the dopaminergic system. To summarize the results of our findings, here we suggest a hypothesis of Alcohol-Related Glucose-Dependent System of Error Monitoring and Processing (ARGD-EMPS hypothesis, which holds that the disruption of the EMPS is related to the competency of glucose homeostasis regulation, which in turn may determine the dopamine level as a major component of the EMPS. The ARGD-EMPS hypothesis explains the general processes and mechanism of alcohol related disruption of the EMPS.Conclusion: Alcohol may indirectly disrupt the EMPS by affecting dopamine level through disorders in blood glucose homeostasis regulation. The

  4. Linear Temporal Logic (LTL) Based Monitoring of Smart Manufacturing Systems

    Science.gov (United States)

    Heddy, Gerald; Huzaifa, Umer; Beling, Peter; Haimes, Yacov; Marvel, Jeremy; Weiss, Brian; LaViers, Amy

    2017-01-01

    The vision of Smart Manufacturing Systems (SMS) includes collaborative robots that can adapt to a range of scenarios. This vision requires a classification of multiple system behaviors, or sequences of movement, that can achieve the same high-level tasks. Likewise, this vision presents unique challenges regarding the management of environmental variables in concert with discrete, logic-based programming. Overcoming these challenges requires targeted performance and health monitoring of both the logical controller and the physical components of the robotic system. Prognostics and health management (PHM) defines a field of techniques and methods that enable condition-monitoring, diagnostics, and prognostics of physical elements, functional processes, overall systems, etc. PHM is warranted in this effort given that the controller is vulnerable to program changes, which propagate in unexpected ways, logical runtime exceptions, sensor failure, and even bit rot. The physical component’s health is affected by the wear and tear experienced by machines constantly in motion. The controller’s source of faults is inherently discrete, while the latter occurs in a manner that builds up continuously over time. Such a disconnect poses unique challenges for PHM. This paper presents a robotic monitoring system that captures and resolves this disconnect. This effort leverages supervisory robotic control and model checking with linear temporal logic (LTL), presenting them as a novel monitoring system for PHM. This methodology has been demonstrated in a MATLAB-based simulator for an industry inspired use-case in the context of PHM. Future work will use the methodology to develop adaptive, intelligent control strategies to evenly distribute wear on the joints of the robotic arms, maximizing the life of the system. PMID:28730154

  5. Network-Oriented Radiation Monitoring System (NORMS)

    Energy Technology Data Exchange (ETDEWEB)

    Rahmat Aryaeinejad; David F. Spencer

    2007-10-01

    We have developed a multi-functional pocket radiation monitoring system capable of detecting and storing gamma ray and neutron data and then sending the data through a wireless connection to a remote central facility upon request. The device has programmable alarm trigger levels that can be modified for specific applications. The device could be used as a stand-alone device or in conjunction with an array to cover a small or large area. The data is stored with a date/time stamp. The device may be remotely configured. Data can be transferred and viewed on a PDA via direct connection or wirelessly. Functional/bench tests have been completed successfully. The device detects low-level neutron and gamma sources within a shielded container in a radiation field of 10 uR/hr above the ambient background level.

  6. Computer system for monitoring power boiler operation

    Energy Technology Data Exchange (ETDEWEB)

    Taler, J.; Weglowski, B.; Zima, W.; Duda, P.; Gradziel, S.; Sobota, T.; Cebula, A.; Taler, D. [Cracow University of Technology, Krakow (Poland). Inst. for Process & Power Engineering

    2008-02-15

    The computer-based boiler performance monitoring system was developed to perform thermal-hydraulic computations of the boiler working parameters in an on-line mode. Measurements of temperatures, heat flux, pressures, mass flowrates, and gas analysis data were used to perform the heat transfer analysis in the evaporator, furnace, and convection pass. A new construction technique of heat flux tubes for determining heat flux absorbed by membrane water-walls is also presented. The current paper presents the results of heat flux measurement in coal-fired steam boilers. During changes of the boiler load, the necessary natural water circulation cannot be exceeded. A rapid increase of pressure may cause fading of the boiling process in water-wall tubes, whereas a rapid decrease of pressure leads to water boiling in all elements of the boiler's evaporator - water-wall tubes and downcomers. Both cases can cause flow stagnation in the water circulation leading to pipe cracking. Two flowmeters were assembled on central downcomers, and an investigation of natural water circulation in an OP-210 boiler was carried out. On the basis of these measurements, the maximum rates of pressure change in the boiler evaporator were determined. The on-line computation of the conditions in the combustion chamber allows for real-time determination of the heat flowrate transferred to the power boiler evaporator. Furthermore, with a quantitative indication of surface cleanliness, selective sootblowing can be directed at specific problem areas. A boiler monitoring system is also incorporated to provide details of changes in boiler efficiency and operating conditions following sootblowing, so that the effects of a particular sootblowing sequence can be analysed and optimized at a later stage.

  7. [The research and expectation on wearable health monitoring system].

    Science.gov (United States)

    Chang, Feiba; Yin, Jun; Zhang, Hehua; Yan, Lexian; Li, Shuying; Zhou, Deqiang

    2015-01-01

    Wearable health monitoring systems that use wearable biosensors capturing human motion and physiological parameters, to achieve the wearer's movement and health management needs. Wearable health monitoring system is a noninvasive continuous detection of human physiological information, data wireless transmission and real-time processing capabilities of integrated system, can satisfy physiological condition monitoring under the condition of low physiological and psychological load. This paper first describes the wearable health monitoring system structure and the relevant technology applied to wearable health monitoring system, and focuses on the current research work what we have done associated with wearable monitoring that wearable respiration and ECG acquisition and construction of electric multi-parameter body area network. Finally, the wearable monitoring system for the future development direction is put forward a simple expectation.

  8. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  9. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  10. Monitoring System with Two Central Facilities Protocol

    Directory of Open Access Journals (Sweden)

    Caesar Firdaus

    2017-03-01

    Full Text Available The security of data and information on government’s information system required proper way of defending against threat. Security aspect can be achieved by using cryptography algorithm, applying information hiding concept, and implementing security protocol. In this research, two central facilities protocol was implemented on Research and Development Center of Mineral and Coal Technology’s Cooperation Contract Monitoring System by utilizing AES and whitespace manipulation algorithm. Adjustment on the protocol by creating several rule of validation ID’s generation and checking processes could fulfill two of four cryptography objectives, consist of authentication and non-repudiation. The solid collaboration between central legitimization agency (CLA, central tabulating facility (CTF, and client is the main idea in two central facilities protocol. The utilization of AES algorithm could defend the data on transmission from man in the middle attack scenario. On the other hand, whitespace manipulation algorithm provided data integrity aspect of the document that is uploaded to the system itself. Both of the algorithm fulfill confidentiality, data integrity, and authentication.

  11. Integrated online condition monitoring system for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, Hashem M. [Analysis and Measurement Services Corporation, Knoxville, TN (United States). AMS Technology Center

    2010-09-15

    Online condition monitoring or online monitoring (OLM) uses data acquired while a nuclear power is operating to continuously assess the health of the plant's sensors, processes, and equipment; to measure the dynamic performance of the plant's process instrumentation; to verify in-situ the calibration of the process instrumentation; to detect blockages, voids, and leaks in the pressure sensing lines; to identify core flow anomalies; to extend the life of neutron detectors and other sensors; and to measure the vibration of reactor internals. Both the steady-state or DC output of plant sensors and their AC signal or noise output can be used to assess sensor health, depending on whether the application is monitoring a rapidly changing (e.g., core barrel motion) or a slowly changing (e.g., sensor calibration) process. The author has designed, developed, installed, and tested OLM systems (comprised of software/hardware-based data acquisition and data processing modules) that integrate low-frequency (1 mHz to 1 Hz) techniques such as RTD cross-calibration, pressure transmitter calibration monitoring, and equipment condition monitoring and high-frequency (1 Hz to 1 kHz) techniques such as the noise analysis technique. The author has demonstrated the noise analysis technique's effectiveness for measuring the dynamic response-time of pressure transmitters and their sensing lines; for performing predictive maintenance on reactor internals; for detecting core flow anomalies; and for extending neutron detector life. Integrated online condition monitoring systems can combine AC and DC data acquisition and signal processing techniques, can use data from existing process sensors during all modes of plant operation, including startup, normal operation, and shutdown; can be retrofitted into existing PWRs, BWRs, and other reactor types and will be integrated into next-generation plants. (orig.)

  12. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  13. Data Acquisition for Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  14. Application of Risk Management for Control and Monitoring Systems

    CERN Document Server

    Grau, S; Balda, F; Chouvelon, A

    2001-01-01

    This paper presents an application of the state of the art and new trends for risk management of safety-related control and monitoring systems, currently applied in the industry. These techniques not only enable to manage safety and reliability issues but they also help in the control of quality and economic factors affected by the availability and maintenance of the system. The method includes an unambiguous definition of the system in terms of functions and a systematic analysis of hazardous situations, undesired events and possible malfunctions. It also includes the identification and quantification of the risk associated to the system. The required risk reduction is specified in terms of safety integrity levels. The safety integrity level results in requirements, preventive measures, possible improvements and recommendations to assure the satisfactory management of the risk.

  15. Developing GP monitoring systems guided by a soft systems approach.

    Science.gov (United States)

    Hindle, T

    1995-11-01

    This paper describes a selected aspect of a research project concerned with 'contracts and competition' in the recently reformed National Health Service. The particular feature highlighted in this paper is the central role played by the general practitioners in the health service as principal sources of the demands made on provider units (particularly hospitals) and, hence, critical determinants of volumes and costs in contracting. A practical outcome of the research has been the development of GP monitoring systems to be used by provider units particularly in the context of marketing-led referral expectations. The approach used to highlight areas of potential GP contract management and monitoring improvements has been a development of soft systems methodology.

  16. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  17. Design of CMS Beam Halo Monitor system

    CERN Document Server

    AUTHOR|(CDS)2078842

    2015-01-01

    A fast and directional monitoring system for the CMS experiment is designed to provide an online, bunch-by-bunch measurement of beam background induced by beam halo interactions, separately for each beam. The background detection is based on Cherenkov radiation produced in synthetic fused silica read out by a fast, UV sensitive photomultiplier tube. Twenty detector units per end will be azimuthally distributed around the rotating shielding of CMS, covering ~408 cm2 at 20.6m from the interaction point, at a radius of ~180 cm. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. A robust multi-layered shielding will enclose each detector unit to protect the photomultiplier tube from the magnetic field and to eliminate the occupancy from low energy particles. The design of the front-end units is validated by experimental results. An overview of the new sy...

  18. Survey of remote data monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Logee, T.L.; Kendall, P.W.; Pollock, E.O.; Raymond, M.G.; Knapp, R.C. Jr.

    1984-09-01

    A self-contained data-logger device called an SDAS (Site Data Acquisition Subsystem) was built for the National Solar Data Network (NSDN) which could collect analog data from 96 channels, store the data for up to three days, and then transmit the stored data on request to a central facility by voice-grade telephone lines. This system has worked fairly well for the eight years that it has been in service. However, the design and components are getting old and newer dataloggers may be more reliable and accurate and less expensive. This report discusses the results of an extensive search for an SDAS replacement. The survey covered 62 models from 36 manufacturers. These numbers are not indicative of all the dataloggers or manufacturers available, but only those which appeared to have some qualifications for the NSDN datalogger replacement. This report views the datalogger as a system which is made up of sensors, a data acquisition and storage unit, a telecommunications subsystem, and a data processing subsystem. Therefore, there is a section on sensors used in the NSDN, telecommunications technology, and data processing requirements. These four components or subsystems are all necessary in order to have an integrated, successful remote data monitoring network.

  19. Enhanced FBG sensor-based system performance assessment for monitoring strain along a prestressed CFRP rod in structural monitoring

    DEFF Research Database (Denmark)

    Kerrouche, A.; Boyle, W.J.O.; Sun, T.

    2009-01-01

    Fiber Bragg grating (FBG) sensor-based systems have been widely used for many engineering applications including most recently a number of applications in structural health monitoring. It is well known that strain and temperature both affect the FBG spectrum which in the interrogation system...... of the existing FBG-based system and the evaluation of the software developed to be compatible with a resolution reaching as high as +/- 0.15 mu epsilon is presented. The system has been tested under particular conditions where a prestressed CFRP (carbon fiber reinforced polymer) rod to which a FBG sensor...... will be converted to a conventional electronic signal. This procedure provides the means for the FBG-based sensor system to be used for several monitoring applications. The aim of this research is to improve an existing monitoring system which has been used for several Held test inspections. A brief description...

  20. ChemAND - a system health monitor for plant chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Turner, C.W.; Mitchel, G.R.; Tosello, G.; Balakrishnan, P.V.; McKay, G.; Thompson, M. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Dundar, Y.; Bergeron, M.; Laporte, R. [Hydro-Quebec, Groupe Chimie, Centrale Nucleaire Gentilly-2, Gentilly, Quebec (Canada)

    2001-03-01

    Effective management of plant systems throughout their lifetime requires much more than data acquisition and display - it requires that the plant's system health be continually monitored and managed. AECL has developed a System Health Monitor called ChemAND for CANDU plant chemistry. ChemAND, a Chemistry ANalysis and Diagnostic system, monitors key chemistry parameters in the heat transport system, moderator-cover gas, annulus gas, and the steam cycle during full-power operation. These parameters can be used as inputs to models that calculate the effect of current plant operating conditions on the present and future health of the system. Chemistry data from each of the systems are extracted on a regular basis from the plant's Historical Data Server and are sorted according to function, e.g., indicators for condenser in-leakage, air in-leakage, heavy water leakage into the annulus gas, fuel failure, etc. Each parameter is conveniently displayed and is trended along with its alarm limits. ChemAND currently includes two analytical models developed for the balance-of-plant. The first model, ChemSolv, calculates crevice chemistry conditions in the steam generator (SG) from either the SG blowdown chemistry conditions or from a simulated condenser leak. This information can be used by plant staff to evaluate the susceptibility of the SG tubes to crevice corrosion. ChemSolv also calculates chemistry conditions throughout the steam-cycle system as determined by the transport of volatile species such as ammonia, hydrazine, morpholine, and oxygen. The second model, SLUDGE, calculates the deposit loading and distribution in the SG as a function of time, based on concentrations of corrosion product in the final feedwater for both normal and start-up conditions. Operations personnel can use this information to predict where to inspect and when to clean. (author)

  1. Electronic Health Monitoring for Space Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Prognostic monitoring capabilities for space exploration aircrafts are crucial to enable safety and reliability in these platforms. Nokomis proposes to develop and...

  2. STRUCTURAL HEALTH MONITORING SYSTEM – AN EMBEDDED SENSOR APPROACH

    Directory of Open Access Journals (Sweden)

    Dhivya. A

    2013-02-01

    Full Text Available Structural Health monitoring system is the implementation of improving the maintenance of any structures like buildings and bridges. It encompasses damage detection, identification and prevention of structures from natural disasters like earth quake and rain. This paper is mainly proposed for three modules. First module constitutes recognizing and alerting of abnormal vibration of the building due to an earth quake. This consists of two types of sensor to predict the abnormal vibration induced by an earth quake. Second module portrays the prediction of damage in the buildings after an earth quake or heavy rain. Damage detection includes identification of crack and the moisture content in wall bricks in real time buildings. Third module presents the smart auditorium which is used to reduce the power consumption. Depending on the number of audience inside the auditorium it can control the electric appliances like fans, lights and speakers. In any real time structural health monitoring system the main issue is the time synchronization. This paper also proposes to overcome the general issue arises in structural health monitoring system. ZigBee based reliable communication is used among the client node and server node. For the secured wireless communication between the nodes ZigBee is used.

  3. Autonomous Monitoring Aerial Robot System for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji H.; Gu, Beom W; Thai, Van X.; Rim, C. T. [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, autonomous monitoring aerial robot system (AMARS), which includes omnidirectional wireless charging platform, aerial robot, landing coils and a battery management board, is proposed to guarantee automatic monitoring of NPPs. The prototype of the system is fabricated, and omnidirectional charging of the system is experimentally validated with 1 C charging state. AR(Aerial Robots)s are essential for NPP accident management because human cannot access to the accident site due to the risks of unexpected explosions, collapses, and high level of radioactive contaminants. Moreover, ARs can support operators to manage normal operation of NPPs built in harsh environment of high temperature and humidity such as UAE Barakah NPP. Because these ARs usually have very low energy capacity, however, the operation time of ARs is less than 30 minutes and should be recharged regularly by human powers, which makes it impossible to monitor NPPs by ARs automatically. In this paper, the concept of AMARS has been proposed and its performance was successfully verified with a fabricated prototype. The charging state of the on board battery in AR was measured as 0.5 C with the induced voltage of 18.6 V, which is well matched to the designed induced voltage when the AR was placed on the edge of the wireless charging platform.

  4. Data Quality Assurance Techniques for a Monitoring and Diagnosis System

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By researching the data quality problem in the monitoring and diagnosis system (MDS),the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.

  5. Exploring No-SQL alternatives for ALMA monitoring system

    Science.gov (United States)

    Shen, Tzu-Chiang; Soto, Ruben; Merino, Patricio; Peña, Leonel; Bartsch, Marcelo; Aguirre, Alvaro; Ibsen, Jorge

    2014-07-01

    The Atacama Large Millimeter /submillimeter Array (ALMA) will be a unique research instrument composed of at least 66 reconfigurable high-precision antennas, located at the Chajnantor plain in the Chilean Andes at an elevation of 5000 m. This paper describes the experience gained after several years working with the monitoring system, which has a strong requirement of collecting and storing up to 150K variables with a highest sampling rate of 20.8 kHz. The original design was built on top of a cluster of relational database server and network attached storage with fiber channel interface. As the number of monitoring points increases with the number of antennas included in the array, the current monitoring system demonstrated to be able to handle the increased data rate in the collection and storage area (only one month of data), but the data query interface showed serious performance degradation. A solution based on no-SQL platform was explored as an alternative to the current long-term storage system. Among several alternatives, mongoDB has been selected. In the data flow, intermediate cache servers based on Redis were introduced to allow faster streaming of the most recently acquired data to web based charts and applications for online data analysis.

  6. A Wearable Sensor System for Monitoring Cigarette Smoking

    Science.gov (United States)

    Sazonov, Edward; Lopez-Meyer, Paulo; Tiffany, Stephen

    2013-01-01

    Objective: Available methods of smoking assessment (e.g., self-report, portable puff-topography instruments) do not permit the collection of accurate measures of smoking behavior while minimizing reactivity to the assessment procedure. This article suggests a new method for monitoring cigarette smoking based on a wearable sensor system (Personal Automatic Cigarette Tracker [PACT]) that is completely transparent to the end user and does not require any conscious effort to achieve reliable monitoring of smoking in free-living individuals. Method: The proposed sensor system consists of a respiratory inductance plethysmograph for monitoring of breathing and a hand gesture sensor for detecting a cigarette at the mouth. The wearable sensor system was tested in a laboratory study of 20 individuals who performed 12 different activities including cigarette smoking. Signal processing was applied to evaluate the uniqueness of breathing patterns and their correlation with hand gestures. Results: The results indicate that smoking manifests unique breathing patterns that are highly correlated with hand-to-mouth cigarette gestures and suggest that these signals can potentially be used to identify and characterize individual smoke inhalations. Conclusions: With the future development of signal processing and pattern-recognition methods, PACT can be used to automatically assess the frequency of smoking and inhalation patterns (such as depth of inhalation and smoke holding) throughout the day and provide an objective method of assessing the effectiveness of behavioral and pharmacological smoking interventions. PMID:24172124

  7. 40 CFR 257.22 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... operator. When physical obstacles preclude installation of ground-water monitoring wells at the relevant... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water......

  8. 40 CFR 258.51 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... preclude installation of ground-water monitoring wells at the relevant point of compliance at existing... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51...

  9. Reactivity Monitoring of Accelerator-Driven Nuclear Reactor Systems

    NARCIS (Netherlands)

    Uyttenhove, W.

    2016-01-01

    This thesis provides a methodology and set-up of a reactivity monitoring tool for Accelerator-Driven Systems (ADS). The reactivity monitoring tool should guarantee the operation of an ADS at a safe margin from criticality. Robustness is assured in different aspects of the monitoring tool: the choice

  10. Reactivity Monitoring of Accelerator-Driven Nuclear Reactor Systems

    NARCIS (Netherlands)

    Uyttenhove, W.

    2016-01-01

    This thesis provides a methodology and set-up of a reactivity monitoring tool for Accelerator-Driven Systems (ADS). The reactivity monitoring tool should guarantee the operation of an ADS at a safe margin from criticality. Robustness is assured in different aspects of the monitoring tool: the choice

  11. Transfer Function Control for Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodinsky, Carlos M. (Inventor)

    2015-01-01

    A modular apparatus for acquiring biometric data may include circuitry operative to receive an input signal indicative of a biometric condition, the circuitry being configured to process the input signal according to a transfer function thereof and to provide a corresponding processed input signal. A controller is configured to provide at least one control signal to the circuitry to programmatically modify the transfer function of the modular system to facilitate acquisition of the biometric data.

  12. Review on Environment Monitoring System and Energy Efficiency

    Directory of Open Access Journals (Sweden)

    Nikita Gaikwad

    2015-07-01

    Full Text Available The Environment monitoring is one of the applications of wireless sensor network. The most serious environment pollution is air pollution because different air pollutant causes damage to human health and causes global warming. To avoid such effect on human health and climate change Environment monitoring systems are used. This paper provides the short overview of different environmental air pollution monitoring systems and Energy efficiency in WSN to reduced the power consumption of system.

  13. Hydrological Monitoring System Design and Implementation Based on IOT

    Science.gov (United States)

    Han, Kun; Zhang, Dacheng; Bo, Jingyi; Zhang, Zhiguang

    In this article, an embedded system development platform based on GSM communication is proposed. Through its application in hydrology monitoring management, the author makes discussion about communication reliability and lightning protection, suggests detail solutions, and also analyzes design and realization of upper computer software. Finally, communication program is given. Hydrology monitoring system from wireless communication network is a typical practical application of embedded system, which has realized intelligence, modernization, high-efficiency and networking of hydrology monitoring management.

  14. Beam Position and Phase Monitor - Wire Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Heath A [Los Alamos National Laboratory; Shurter, Robert B. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory

    2012-04-10

    The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

  15. Design Scheme of Remote Monitoring System Based on Qt

    Directory of Open Access Journals (Sweden)

    Xu Dawei

    2015-01-01

    Full Text Available This paper introduces a design scheme of remote monitoring system based on Qt, the scheme of remote monitoring system based on S3C2410 and Qt, with the aid of cross platform development tools Qt and powerful ARM platform design and implementation. The development of remote video surveillance system based on embedded terminal has practical significance and value.

  16. 78 FR 11090 - Steel Import Monitoring and Analysis System

    Science.gov (United States)

    2013-02-15

    ... International Trade Administration 19 CFR Part 360 RIN 0625-AA93 Steel Import Monitoring and Analysis System... to extend the Steel Import Monitoring and Analysis (SIMA) system until March 21, 2017. The purpose of the SIMA system is to provide the public statistical data on steel imports entering the United...

  17. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be...

  18. An advanced condition monitoring system for turbopumps

    Science.gov (United States)

    Cross, George S.; Barkhoudarian, Sarkis

    1991-01-01

    Advanced condition monitoring (ACM) technologies developed for in situ turbomachinery applications are reviewed. The ACM concepts are based on direct in situ hardware monitoring and between-flight inspections, using novel real-time, automated, noncontacting, and nonintrusive sensor and associated electronic technologies.

  19. Challenges for Life Support Systems in Space Environments, Including Food Production

    Science.gov (United States)

    Wheeler, Raymond M.

    2012-01-01

    Environmental Control and Life Support Systems (ECLSS) refer to the technologies needed to sustain human life in space environments. Histor ically these technologies have focused on providing a breathable atmo sphere, clean water, food, managing wastes, and the associated monitoring capabilities. Depending on the space agency or program, ELCSS has sometimes expanded to include other aspects of managing space enviro nments, such as thermal control, radiation protection, fire detection I suppression, and habitat design. Other times, testing and providing these latter technologies have been associated with the vehicle engi neering. The choice of ECLSS technologies is typically driven by the mission profile and their associated costs and reliabilities. These co sts are largely defined by the mass, volume, power, and crew time req uirements. For missions close to Earth, e.g., low-Earth orbit flights, stowage and resupply of food, some 0 2, and some water are often the most cost effective option. But as missions venture further into spa ce, e.g., transit missions to Mars or asteroids, or surface missions to Moon or Mars, the supply line economics change and the need to clos e the loop on life support consumables increases. These are often ref erred to as closed loop or regenerative life support systems. Regardless of the technologies, the systems must be capable of operating in a space environment, which could include micro to fractional g setting s, high radiation levels, and tightly closed atmospheres, including perhaps reduced cabin pressures. Food production using photosynthetic o rganisms such as plants by nature also provides atmospheric regenerat ion (e.g., CO2 removal and reduction, and 0 2 production), yet to date such "bioregenerative" technologies have not been used due largely t o the high power requirements for lighting. A likely first step in te sting bioregenerative capabilities will involve production of small a mounts of fresh foods to supplement to crew

  20. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. Here, I present the detector...

  1. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly Marie

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to supress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will descri...

  2. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  3. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  4. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  5. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  6. Application of a microseismic monitoring system in deep mining

    Institute of Scientific and Technical Information of China (English)

    Chengxiang Yang; Zhouquan Luo; Guobin Hu; Xiaoming Liu

    2007-01-01

    A microseismic monitoring system was used in the Donggua Shan underground copper mine,and its application was introduced.The spacial distribution of the seismic event was monitored effectively during mining with this system.The distribution of the seismic intensity in different time periods and in the different mining districts was obtained via the clustering analysis of the monitored results,and the different intensity concentration districts of seismicity were compartmentalized.The various characteristics and waveforms of different vibrations in the underground mine were revealed with the help of the micro-seismic monitoring system.It was proved that the construction and application of the micro-seismic monitoring system in the mine not only realized the continuous monitoring of seismicity in the deep mine,but also settled an important foundation for further studies on hazard prediction,based on this system.

  7. Online Monitor Framework for Network Distributed Data Acquisition Systems

    Science.gov (United States)

    Konno, Tomoyuki; Cabrera, Anatael; Ishitsuka, Masaki; Kuze, Masahiro; Sakamoto, Yasunobu; the Double Chooz Collaboration

    Data acquisition (DAQ) systems for recent high energy physics experiments consist of lots of subsystems distributed in the local area network. Therefore, scalability for the number of connections from subsystems and availability of access via the Internet are required. "Online monitor framework" is a general software framework for online data monitoring, which provides a way to collect monitoring information distributed in the network and pass them though the firewalls. The framework consists of two subsystems; "Monitor Sever" and "Monitor Viewer". Monitor Server is a core system of the framework. The server collects monitoring information from the DAQ subsystems to provide them to Monitor Viewer. Monitor Viewer is a graphical user interface of the monitor framework, which displays plots in itself. We adapted two types of technologies; Java and HTML5 with Google Web Toolkit, which are independent of operating systems or plugin-libraries like ROOT and contain some functionalities of communicating via the Internet and drawing graphics. The monitoring framework was developed for the Double Chooz reactor neutrino oscillation experiment but is general enough for other experiments. This document reports the structure of the online monitor framework with some examples from the adaption to the Double Chooz experiment.

  8. Implementation of a Portable Personal EKG Signal Monitoring System

    Science.gov (United States)

    Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng

    This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.

  9. Mekong Regional Land Cover Monitoring System Reference Methods

    Science.gov (United States)

    Saah, D.; Aekakkararungroj, A.; Phongsapan, K.; Towashiraporn, P.; Triepke, J.; Maus, P.; Tenneson, K.; Anderson, E.; Cutter, P. G.; Ganz, D.; Ate, P.; Markert, K. N.

    2016-12-01

    In 2015, SERVIR-Mekong conducted a geospatial needs assessment for the Lower Mekong countries which included individual country consultations. The assessment revealed that many countries were dependent on land cover and land use maps for land resource planning, quantifying ecosystem services including resilience to climate change, biodiversity conservation, and other critical social issues. Many of the Lower Mekong countries have developed national scale land cover maps derived in part from remote sensing products and geospatial technologies. However, updates are infrequent and classification systems and accuracy assessment do not always meet the needs of key user groups. In addition, data products stop at political boundaries and are often not accessible. Many of the Lower Mekong countries rely on global land cover products to fill the gaps of their national efforts, compromising consistency between data and policies. These gaps in national efforts can be filled by a flexible regional land cover monitoring system that is co-developed by regional partners with the specific intention of meeting national transboundary needs, for example including consistent forest definitions in transboundary watersheds. During this assessment, regional stakeholders identified a need for a land cover monitoring system that will produce frequent, high quality land cover maps using a consistent regional classification scheme that is compatible with national country needs. This system is dependent on a sustainable source of field data that insures data quality and improves potential impact. Based on this need a collaborative workshop was held to create a robust regional reference data system that integrates results from field data, national inventories and high resolution imagery. The results presented here highlights the value of collaboratively developed systems that use data convergence to improve land cover mapping results for multiple end users.

  10. Extended Darknet: Multi-Dimensional Internet Threat Monitoring System

    Science.gov (United States)

    Shimoda, Akihiro; Mori, Tatsuya; Goto, Shigeki

    Internet threats caused by botnets/worms are one of the most important security issues to be addressed. Darknet, also called a dark IP address space, is one of the best solutions for monitoring anomalous packets sent by malicious software. However, since darknet is deployed only on an inactive IP address space, it is an inefficient way for monitoring a working network that has a considerable number of active IP addresses. The present paper addresses this problem. We propose a scalable, light-weight malicious packet monitoring system based on a multi-dimensional IP/port analysis. Our system significantly extends the monitoring scope of darknet. In order to extend the capacity of darknet, our approach leverages the active IP address space without affecting legitimate traffic. Multi-dimensional monitoring enables the monitoring of TCP ports with firewalls enabled on each of the IP addresses. We focus on delays of TCP syn/ack responses in the traffic. We locate syn/ack delayed packets and forward them to sensors or honeypots for further analysis. We also propose a policy-based flow classification and forwarding mechanism and develop a prototype of a monitoring system that implements our proposed architecture. We deploy our system on a campus network and perform several experiments for the evaluation of our system. We verify that our system can cover 89% of the IP addresses while darknet-based monitoring only covers 46%. On our campus network, our system monitors twice as many IP addresses as darknet.

  11. Geographic information system planning and monitoring best ...

    African Journals Online (AJOL)

    emeje

    Key words: GIS, Urban Planning, Urban Monitoring, West Africa, Best Practices, Pollution, flooding .... infrastructure and space, evident in cities such as Lagos,. Kano ... earmarked as green belts are being taken over by corner shops, roads ...

  12. Design of Wind Turbine Vibration Monitoring System

    National Research Council Canada - National Science Library

    Shoubin Wang; Wei Gong; Gang Su; Hongyue Sun

    2013-01-01

    In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed...

  13. Monitored Retrievable Storage System Requirements Document. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    This Monitored Retrievable Storage System Requirements Document (MRS-SRD) describes the functions to be performed and technical requirements for a Monitored Retrievable Storage (MRS) facility subelement and the On-Site Transfer and Storage (OSTS) subelement. The MRS facility subelement provides for temporary storage, at a Civilian Radioactive Waste Management System (CRWMS) operated site, of spent nuclear fuel (SNF) contained in an NRC-approved Multi-Purpose Canister (MPC) storage mode, or other NRC-approved storage modes. The OSTS subelement provides for transfer and storage, at Purchaser sites, of spent nuclear fuel (SNF) contained in MPCs. Both the MRS facility subelement and the OSTS subelement are in support of the CRWMS. The purpose of the MRS-SRD is to define the top-level requirements for the development of the MRS facility and the OSTS. These requirements include design, operation, and decommissioning requirements to the extent they impact on the physical development of the MRS facility and the OSTS. The document also presents an overall description of the MRS facility and the OSTS, their functions (derived by extending the functional analysis documented by the Physical System Requirements (PSR) Store Waste Document), their segments, and the requirements allocated to the segments. In addition, the top-level interface requirements of the MRS facility and the OSTS are included. As such, the MRS-SRD provides the technical baseline for the MRS Safety Analysis Report (SAR) design and the OSTS Safety Analysis Report design.

  14. Autonomous underwater pipeline monitoring navigation system

    Science.gov (United States)

    Mitchell, Byrel; Mahmoudian, Nina; Meadows, Guy

    2014-06-01

    This paper details the development of an autonomous motion-control and navigation algorithm for an underwater autonomous vehicle, the Ocean Server IVER3, to track long linear features such as underwater pipelines. As part of this work, the Nonlinear and Autonomous Systems Laboratory (NAS Lab) developed an algorithm that utilizes inputs from the vehicles state of the art sensor package, which includes digital imaging, digital 3-D Sidescan Sonar, and Acoustic Doppler Current Profilers. The resulting algorithms should tolerate real-world waterway with episodic strong currents, low visibility, high sediment content, and a variety of small and large vessel traffic.

  15. Pier scour monitoring system by bed-level image tracking

    Institute of Scientific and Technical Information of China (English)

    Wen-Yi CHANG; Jihn-Sung LAI; Teng-Yi YU; Franco LIN; Lung-Cheng LEE; Whey-Fone TSAI; Chin-Hsiung LOH

    2014-01-01

    A scour monitoring system with a micro camera tracking the bed-level images is proposed in this study. Two image recognition algorithms have been developed to support the bed-level image tracking approach. Through the laboratory experiments of pier scour, this study demonstrates that the proposed system is able to accurately monitor the scour-depth evolution in real time. In addition, five commonly-used temporal scour models are employed to simulate scour-depth evolution and their results are compared with monitoring data. In general, the results indicate that the proposed scour monitoring system has the potential for further applications in the field.

  16. A Microprocessor-Based System for Monitoring Gas Turbines

    Directory of Open Access Journals (Sweden)

    P. K.S. Shrivastava

    1989-04-01

    Full Text Available The development and testing of hardware and software for a microprocessor-based monitoring system for gas turbines is described in this paper. The operators of gas turbines can be trained to monitor running hours, slip between high and low pressure compressor spools and torque on the reduction gear-box under various conditions ofoperation. The system will replace the traditional method of monitoring these parameters which are more time consuming and error prone.

  17. Review on Environment Monitoring System and Energy Efficiency

    OpenAIRE

    Nikita Gaikwad; Yogita Mistry

    2015-01-01

    The Environment monitoring is one of the applications of wireless sensor network. The most serious environment pollution is air pollution because different air pollutant causes damage to human health and causes global warming. To avoid such effect on human health and climate change Environment monitoring systems are used. This paper provides the short overview of different environmental air pollution monitoring systems and Energy efficiency in WSN to reduced the power consumption ...

  18. Development of environmental monitoring satellite systems in China

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    With the increase in global environmental problems,the necessity and urgency of remote sensing technology being applied to environmental monitoring has been widely recognized around the world.China has launched the environment and disaster monitoring and forecasting small satellite constellation HJ-1A/B and the FY3 atmosphere and environmental satellite,but they still cannot fully satisfy requirements for environmental monitoring.This paper summarizes the current status of satellite environmental monitoring in China and the existing problems of inadequate load design and low data utilization efficiency,and discusses the demand for environmental monitoring satellites.Based on the development of foreign satellite systems for environmental monitoring,the future development and key tasks of the environmental monitoring satellite system in China is discussed,as are some related initiatives.

  19. An intelligent health monitoring system using radio-frequency identification technology.

    Science.gov (United States)

    Lai, Yeong-Lin; Chen, Chin-Ling; Chang, Ching-Hisang; Hsu, Chih-Yu; Lai, Yeong-Kang; Tseng, Kuo-Kun; Chen, Chih-Cheng; Zheng, Chun-Yi

    2015-01-01

    Long-term care (LTC) for the elderly has become extremely important in recent years. It is necessary for the different physiological monitoring systems to be integrated on the same interface to help oversee and manage the elderly's needs. This paper presents a novel health monitoring system for LTC services using radio-frequency identification (RFID) technology. Dual-band RFID protocols were included in the system, in which the high-frequency (HF) band of 13.56 MHz was used to identify individuals and the microwave band of 2.45 GHz was used to monitor physiological information. Distinct physiological data, including oxyhemoglobin saturation by pulse oximetry (SpO2), blood pressure, blood sugar, electrocardiogram (ECG) readings, body temperature, and respiration rate, were monitored by various biosensors. The intelligent RFID health monitoring system provided the features of the real-time acquisition of biomedical signals and the identification of personal information pertaining to the elderly and patients in nursing homes.

  20. Engineering Runtime Requirements-Monitoring Systems Using MDA Technologies

    Science.gov (United States)

    Skene, James; Emmerich, Wolfgang

    The Model-Driven Architecture (MDA) technology toolset includes a language for describing the structure of meta-data, the MOF, and a language for describing consistency properties that data must exhibit, the OCL. Off-the-shelf tools can generate meta-data repositories and perform consistency checking over the data they contain. In this paper we describe how these tools can be used to implement runtime requirements monitoring of systems by modelling the required behaviour of the system, implementing a meta-data repository to collect system data, and consistency checking the repository to discover violations. We evaluate the approach by implementing a contract checker for the SLAng service-level agreement language, a language defined using a MOF meta-model, and integrating the checker into an Enterprise JavaBeans application. We discuss scalability issues resulting from immaturities in the applied technologies, leading to recommendations for their future development.

  1. Integrated monitoring and surveillance system demonstration project: Phase I accomplishments

    Energy Technology Data Exchange (ETDEWEB)

    Aumeier, S.E.; Walters, B.G.; Crawford, D.C. [and others

    1997-01-15

    The authors present the results of the Integrated Monitoring and Surveillance System (IMSS) demonstration project Phase I efforts. The rationale behind IMSS development is reviewed and progress in each of the 5 basic tasks is detailed. Significant results include decisions to use Echelon LonWorks networking protocol and Microsoft Access for the data system needs, a preliminary design for the plutonium canning system glovebox, identification of facilities and materials available for the demonstration, determination of possibly affected facility documentation, and a preliminary list of available sensor technologies. Recently imposed changes in the overall project schedule and scope are also discussed and budgetary requirements for competition of Phase II presented. The results show that the IMSS demonstration project team has met and in many cases exceeded the commitments made for Phase I deliverables.

  2. 47 CFR 76.614 - Cable television system regular monitoring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system regular monitoring. 76.614 Section 76.614 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.614 Cable television system regular monitoring. Cable television...

  3. Seismic monitoring: a unified system for research and verifications

    Energy Technology Data Exchange (ETDEWEB)

    Thigpen, L.

    1979-02-06

    A system for characterizing either a seismic source or geologic media from observational data was developed. This resulted from an examination of the forward and inverse problems of seismology. The system integrates many seismic monitoring research efforts into a single computational capability. Its main advantage is that it unifies computational and research efforts in seismic monitoring. 173 references, 9 figures, 3 tables.

  4. 50 CFR 660.312 - Vessel Monitoring System (VMS) requirements.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel Monitoring System (VMS... West Coast Groundfish Fisheries § 660.312 Vessel Monitoring System (VMS) requirements. (a) What is a VMS? A VMS consists of a NMFS OLE type-approved mobile transceiver unit that automatically...

  5. ATLAS Pixel Radiation Monitoring with HVPP4 System

    CERN Document Server

    Gorelov, Igor; Seidel, Sally; Toms, Konstantin

    2009-01-01

    In this talk we present the basis for the protocol for radiation monitoring of the ATLAS Pixel Sensors. The monitoring is based on a current measurement system, HVPP4. The status on the ATLAS HVPP4 system development is also presented.

  6. 77 FR 67593 - Steel Import Monitoring and Analysis System

    Science.gov (United States)

    2012-11-13

    ... International Trade Administration 19 CFR Part 360 RIN 0625-AA93 Steel Import Monitoring and Analysis System... modifications to the regulations for the Steel Import Monitoring and Analysis (SIMA) System that would extend... as possible certain steel mill imports into the United States and make the import data...

  7. [A wireless mobile monitoring system based on bluetooth technology].

    Science.gov (United States)

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  8. Fault Detection for Shipboard Monitoring and Decision Support Systems

    DEFF Research Database (Denmark)

    Lajic, Zoran; Nielsen, Ulrik Dam

    2009-01-01

    In this paper a basic idea of a fault-tolerant monitoring and decision support system will be explained. Fault detection is an important part of the fault-tolerant design for in-service monitoring and decision support systems for ships. In the paper, a virtual example of fault detection will be p...

  9. Modular Integrated Monitoring System (MIMS) field test installations

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, R.L.; Waymire, D.R. [Sandia National Labs., Albuquerque, NM (United States); Fuess, D.A. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-07-01

    The MIMS program is funded by the Department of Energy under the Office of Nonproliferation and National Security. The program objective is to develop cost effective, modular, multi-sensor monitoring systems. Both in-plant and ground based sensors are envisioned. It is also desirable to develop sensors/systems that can be fielded/deployed in a rapid fashion. A MIMS architecture was selected to allow modular integration of sensors and systems and is based on LonWorks technology, commercially developed by Echelon Corporation. The first MIMS fieldable hardware was demonstrated at Lawrence Livermore National Laboratory. The field test, known within the DOE as the Item Tracking and Transparency (IT&I) demonstration, involved the collaboration and cooperation of five DOE laboratories (Sandia (SNL), Lawrence Livermore (LLNL), Pacific Northwest (PNL), Los Alamos (LANL), and Oak Ridge (ORNL)). The IT&T demonstration involved the monitoring of special nuclear material as it was transported around the facility utilizing sensors from the participating labs. The scenario was programmed to ignore normal activity in the facility until entry into the room where the material was stored. A second demonstration, which involved three separate scenarios, was conducted at Idaho National Engineering Laboratory (INEL). The participants included representatives from SNL, LLNL, PNL, and INEL. DOE has selected INEL as the long term testbed for MIMS developed sensors, systems, and scenarios. This paper will describe the installation, intended purpose, and results of the field demonstrations at LLNL and INEL under the MIMS program.

  10. Polymerization monitoring in plasma etching systems

    Science.gov (United States)

    Kim, Jinsoo

    1999-11-01

    -suppressing nature of the oxide etch. A new sensor for monitoring polymer buildup in plasma etching systems was designed, fabricated, and tested as part of this work. The device is mounted flush in the chamber wall and uses an electrothermal oscillator to measure the thermal mass change of a micromachined dielectric window as polymer deposits on it. The variation in the oscillation pulse width (cooling time) is used as the sensor output. The device operates with a typical cooling time of 2.7msec and has a thickness resolution of modified to add the needed micromachining steps, and photoresist masking was explored for the first time to protect the devices from silicon etchant (tetramethyl ammonium hydroxide: TMAH) attack. A chevron-based support structure is used on the back side of the wafer to hold the devices in wafer form after micromachining to allow testing, high-yield die separation, and non-lithographic post-TMAH processing. The device metallization, package, and O-ring-based placement structure have been designed to ensure compatibility with the plasma etching environment.

  11. Automatic vehicle counting system for traffic monitoring

    Science.gov (United States)

    Crouzil, Alain; Khoudour, Louahdi; Valiere, Paul; Truong Cong, Dung Nghy

    2016-09-01

    The article is dedicated to the presentation of a vision-based system for road vehicle counting and classification. The system is able to achieve counting with a very good accuracy even in difficult scenarios linked to occlusions and/or presence of shadows. The principle of the system is to use already installed cameras in road networks without any additional calibration procedure. We propose a robust segmentation algorithm that detects foreground pixels corresponding to moving vehicles. First, the approach models each pixel of the background with an adaptive Gaussian distribution. This model is coupled with a motion detection procedure, which allows correctly location of moving vehicles in space and time. The nature of trials carried out, including peak periods and various vehicle types, leads to an increase of occlusions between cars and between cars and trucks. A specific method for severe occlusion detection, based on the notion of solidity, has been carried out and tested. Furthermore, the method developed in this work is capable of managing shadows with high resolution. The related algorithm has been tested and compared to a classical method. Experimental results based on four large datasets show that our method can count and classify vehicles in real time with a high level of performance (>98%) under different environmental situations, thus performing better than the conventional inductive loop detectors.

  12. 40 CFR Table 31 to Subpart Uuu of... - Continuous Monitoring Systems for HAP Emissions From Sulfur Recovery Units

    Science.gov (United States)

    2010-07-01

    ... stack; this monitor must include an oxygen monitor for correcting the data for excess oxygen; or ii... hourly average concentration of SO2 (dry basis) at zero percent excess air for each exhaust stack. This system must include an oxygen monitor for correcting the data for excess air. b. 300 ppmv of...

  13. A Graphical User Interface in WLAN Monitoring and Management System

    Directory of Open Access Journals (Sweden)

    Jiantao Gu

    2012-04-01

    Full Text Available This paper aims at providing a graphical user interface for WLAN monitoring and management system “WLAN Inspector”, which gives network operators the software and performance management tools necessary to monitor and manage network availability, achieve real-time monitoring (7 × 24 hours and intelligent management, report on IP networks performance, and troubleshoot issues through a single Web-based graphical user interface. The overall framework design of graphical interface, brief description of each module, and the detailed design in the basic information interface are discussed in this paper. The WLAN monitoring and management system has multiple functions: real-time network monitoring, real-time protocol analysis, information, statistics, safety testing and network performance monitoring, etc. This system can give Video Frame Capture for Mac, analyze the WLAN traffic characteristics, detect possible security vulnerabilities, and give the appropriate solution.

  14. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The on-ground and Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) provides a system architecture and software tools for performing diagnostics...

  15. Efficient Network Monitoring for Large Data Acquisition Systems

    CERN Document Server

    Savu, DO; The ATLAS collaboration; Al-Shabibi, A; Sjoen, R; Batraneanu, SM; Stancu, SN

    2011-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed real-time data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and...

  16. Development and prospects of the fire space monitoring system in Kazakhstan

    Institute of Scientific and Technical Information of China (English)

    Lev SPIVAK; Oleg ARKHIPKIN; Gulshat SAGATDINOVA

    2012-01-01

    This article provides a brief description of the fire space monitoring system in Kazakhstan,including the GIS-technology incorporated in its structure.The system performs operative space monitoring of fire areas and burnt areas,mapping of large fire areas,analysis of seasonal and long-term dynamics of burnt areas,and estimation of fire risk zones.Examples of output information obtained from space monitoring of fires are given.Possible directions of development of fire space monitoring in Kazakhstan are specified.

  17. [Implementation of ECG Monitoring System Based on Internet of Things].

    Science.gov (United States)

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  18. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  19. Flood and Traffic Wireless Monitoring System for Smart Cities

    KAUST Repository

    Moussa, Mustafa

    2016-10-01

    The convergence of computation, communication and sensing has led to the emergence of Wireless Sensor Networks (WSNs), which allow distributed monitoring of physical phenomena over extended areas. In this thesis, we focus on a dual flood and traffic flow WSN applicable to urban environments. This fixed sensing system is based on the combination of ultrasonic range-finding with remote temperature sensing, and can sense both phenomena with a high degree of accuracy. This enables the monitoring of urban areas to lessen the impact of catastrophic flood events, by monitoring flood parameters and traffic flow to enable public evacuation and early warning, allocate the resources efficiently or control the traffic to make cities more productive and smarter. We present an implementation of the device, and illustrate its performance in water level estimation and rain detection using a novel combination of L1 regularized reconstruction and machine learning algorithms on a 6-month dataset involving four different sensors. Our results show that water level can be estimated with an uncertainty of 1 cm using a combination of thermal sensing and ultrasonic distance measurements. The demonstration of the performance included the detection of an actual flash flood event using two sensors located in Umm Al Qura University (Mecca). Finally, we show that Lagrangian (mobile) sensors can be used to inexpensively increase the performance of the system with respect to traffic sensing. These sensors are based on Inertial Measurement Units (IMUs), which have never been investigated in the context of traffic ow monitoring before. We investigate the divergence of the speed estimation process, the lack of the calibration parameters of the system, and the problem of reconstructing vehicle trajectories evolving in a given transportation network. To address these problems, we propose an automatic calibration algorithm applicable to IMU-equipped ground vehicles, and an L1 regularized least squares

  20. Standard-B Hydrogen Monitoring System, system design description

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1995-01-16

    During most of the year, it is assumed that the vapor in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gases to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gases from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. This document describes the design of the Standard-B Hydrogen Monitoring System, (SHMS) and its components as it differs from the original SHMS. The differences are derived from changes made to improve the system performance but not implemented in all the installed enclosures.

  1. Smart Structures and Intelligent Systems for Health Monitoring and Diagnostics

    Directory of Open Access Journals (Sweden)

    M. A. El-Sherif

    2005-01-01

    Full Text Available “Smart and intelligent” structures are defined as structures capable of monitoring their own “health” condition and structural behavior, such structures are capable of sensing external environmental conditions, making decisions, and sending the information to other locations. Available conventional devices and systems are not technologically mature for such applications. New classes of miniature devices and networking systems are urgently needed for such applications. In this paper, two examples of the successful work achieved so far, in biomedical application of smart structures, are presented. The first one is based on the development of a smart bone fixation device for rehabilitation and treatment. This device includes a smart composite bar that can sense physical stress applied to the fractured bones, and send the information to the patient's physician remotely. The second is on the development of smart fabrics for many applications including health monitoring and diagnostics. Successful development of such smart fabrics with embedded fiber optic sensors and networks is mainly dependent on the development of the proper miniature sensor technology, and on the integration of these sensors into textile structures. The developed smart structures will be discussed and samples of the results will be presented.

  2. Development of mobile air pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  3. Monitoring of PON System Using Compound Surveillance Technique

    Institute of Scientific and Technical Information of China (English)

    Sun-Chien Ko; Hsiu-Jung Chuang; Si-Chong Chen; Chih-Yih Wang; Sheng-Fwu Lin

    2015-01-01

    A passive optical network (PON) monitoring system combined light pulse and frequency sweep techniques is proposed and verified in a field test. The light pulse surveys over the all whole network and the frequency sweep are used to investigate any fault in the link. The field test is performed with 4 PONs. Each PON is monitored at 4 ports, one is the splitter port and the other three are arbitrary chosen multiple optical units(ONUs). All the tested PONs are monitored in turns once per hour. Faults at the feeder and branch fiber have been observed in this field test and have been analyzed with the monitoring system.

  4. Development of mobile air pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  5. Large-Scale Wireless Temperature Monitoring System for Liquefied Petroleum Gas Storage Tanks

    Directory of Open Access Journals (Sweden)

    Guangwen Fan

    2015-09-01

    Full Text Available Temperature distribution is a critical indicator of the health condition for Liquefied Petroleum Gas (LPG storage tanks. In this paper, we present a large-scale wireless temperature monitoring system to evaluate the safety of LPG storage tanks. The system includes wireless sensors networks, high temperature fiber-optic sensors, and monitoring software. Finally, a case study on real-world LPG storage tanks proves the feasibility of the system. The unique features of wireless transmission, automatic data acquisition and management, local and remote access make the developed system a good alternative for temperature monitoring of LPG storage tanks in practical applications.

  6. Remote real-time monitoring soil water potential system based on GSM

    Institute of Scientific and Technical Information of China (English)

    Yongming Zhao; Xin Lu; Haijiang Wang

    2008-01-01

    Aiming at the limitation of traditional measuring soil water potential, the paper presents an information system based GSM to real-time monitor data coming from multiple data sources. The monitoring system, which consisted of monitoring center, GSM transmission channel and data detection terminal, was given. The detection terminal included the measuring station and TS-2 negative pressure meter, which was applied to measure soil water potential. Nowadays the system has been successfully applied to drip irrigation in the cotton field on farm in Xinjiang region. The system provides a feasible technology frame-work for collecting and processing wide geographical distribution data in farmland.

  7. A New Architecture of a Ubiquitous Health Monitoring System: A Prototype Of Cloud Mobile Health Monitoring System

    CERN Document Server

    Bourouis, Abderrahim; Bouchachia, Abdelhamid

    2012-01-01

    Wireless Body Area Sensor Networks (WBASN) is an emerging technology which uses wireless sensors to implement real-time wearable health monitoring of patients to enhance independent living. In this paper we propose a prototype of cloud mobile health monitoring system. The system uses WBASN and Smartphone application that uses cloud computing, location data and a neural network to determine the state of patients.

  8. An Update on ConSys Including a New LabVIEW FPGA Based LLRF System

    DEFF Research Database (Denmark)

    Worm, Torben; Nielsen, Jørgen S.

    . This system use a National Instruments NI-PCIe7852R DAQ card, which includes an on-board FPGA and are hosted in a standard PC. The fast (50 kHz) amplitude loop has been implemented on the FPGA, whereas the slower tuning and phase loops are implemented in the real-time system. An operator interface including...

  9. Intelligent Monitoring of Rocket Test Systems

    Science.gov (United States)

    Duran, Esteban; Rocha, Stephanie; Figueroa, Fernando

    2016-01-01

    Stephanie Rocha is an undergraduate student pursuing a degree in Mechanical Engineering. Esteban Duran is pursuing a degree in Computer Science. Our mentor is Fernando Figueroa. Our project involved developing Intelligent Health Monitoring at the High Pressure Gas Facility (HPGF) utilizing the software GensymG2.

  10. Information Fusion of Online Oil Monitoring System Using Multiple Sensors

    Institute of Scientific and Technical Information of China (English)

    高慧良; 周新聪; 程海明; 赵春华; 严新平

    2004-01-01

    Machine lubrication contains abundant information on the equipment operation.Nowadays, most measuring methods are based on offline sampling or on online measuring with a single sensor.An online oil monitoring system with multiple sensors was designed.The measurement data was processed with a fuzzy intelligence system.Information from integrated sensors in an oil online monitoring system was evaluated using fuzzy logic.The analyses show that the multiple sensors evaluation results are more reliable than online monitoring systems with single sensors.

  11. Wireless sensor systems and methods, and methods of monitoring structures

    Science.gov (United States)

    Kunerth, Dennis C.; Svoboda, John M.; Johnson, James T.; Harding, L. Dean; Klingler, Kerry M.

    2007-02-20

    A wireless sensor system includes a passive sensor apparatus configured to be embedded within a concrete structure to monitor infiltration of contaminants into the structure. The sensor apparatus includes charging circuitry and a plurality of sensors respectively configured to measure environmental parameters of the structure which include information related to the infiltration of contaminants into the structure. A reader apparatus is communicatively coupled to the sensor apparatus, the reader apparatus being configured to provide power to the charging circuitry during measurements of the environmental parameters by the sensors. The reader apparatus is configured to independently interrogate individual ones of the sensors to obtain information measured by the individual sensors. The reader apparatus is configured to generate an induction field to energize the sensor apparatus. Information measured by the sensor apparatus is transmitted to the reader apparatus via a response signal that is superimposed on a return induction field generated by the sensor apparatus. Methods of monitoring structural integrity of the structure are also provided.

  12. A wireless portable system with microsensors for monitoring respiratory diseases.

    Science.gov (United States)

    Cao, Zhe; Zhu, Rong; Que, Rui-Yi

    2012-11-01

    A wireless portable monitoring system for respiratory diseases using microsensors is proposed. The monitoring system consists of two sensor nodes integrating with Bluetooth transmitters that measure user's respiratory airflow, blood oxygen saturation, and body posture. The utility of micro-hot-film flow sensor makes the monitor can acquire comprehensive respiration parameters which are useful for diagnoses of obstructive sleep apnea, chronic obstructive pulmonary disease, and asthma. The system can serve as both sleep recorder and spirometer. Additionally, a mobile phone or a PC connected to the Internet serving as a monitoring and transfer terminal makes telemedicine achievable. Several experiments were conducted to verify the feasibility and effectiveness of the proposed system for monitoring and diagnosing OSA, COPD, and asthma.

  13. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  14. New problems and opportunities of oil spill monitoring systems

    Directory of Open Access Journals (Sweden)

    G. M. Barenboim

    2015-04-01

    Full Text Available Emergency oil and oil products spills represent a great danger to the environment, including ecosystems, and to the population. New problems of such dangerous spills and methods of early detection are discussed in this paper. It is proposed to conduct assessment of biological hazards of such spills on the basis of data on the distribution of individual oil hydrocarbons within the column of the water body and computer predictions of their toxicity. Oil radioactivity, which is associated with uranium and thorium, is seen as the important aspect of the oil spill danger, especially in watercourses. The need for an automated monitoring system for the early detection of oil spills in water bodies is analysed. The proposed system consists of three subsystems. The first remote sensing subsystem is based on powerful fluorescent lidars; experimental results on lidar registration of oil pollution of water are reported. The second subsystem uses a network of automatic monitoring stations with contact detectors. The third subsystem is the combined sensor system based on remote and contact technologies.

  15. Urgent problems of improving background air pollution monitoring systems.

    Science.gov (United States)

    Berlyand, M E; Volberg, N S; Lavrinenko, R F; Rusina, E N

    1988-01-01

    For more than 12 years, systematic observations of background air pollution have been carried out in accordance with the WMO Programme using the network of USSR stations located in sparsely populated settlements and in a number of neighbouring cities. The parameters involved include spectral radiation measurements, determination of chemical composition of precipitation and the concentrations of a number of atmospheric pollutants. Analysis of the data obtained allows conclusions to be drawn on the capabilities of the current system and to evaluate methods of improving it.In order to further improve the monitoring system, it is recommended that the system should perform the same observations on air pollution and precipitation as carried out by other international and national programs, and also to create centralized laboratories to deal with the analysis of samples from these monitoring stations. Additionally, solid sorbents are emerging as an effective means of sampling certain air pollutants. They may be sent by post, they increase the accuracy of measurements and allow air sampling intervals of up to 7-10 days, thus synchronizing this period with the interval of precipitation sampling.

  16. Principles in wireless building health monitoring systems.

    Science.gov (United States)

    Pentaris, F. P.; Makris, J. P.; Stonham, J.; Vallianatos, F.

    2012-04-01

    Monitoring the structural state of a building is essential for the safety of the people who work, live, visit or just use it as well as for the civil protection of urban areas. Many factors can affect the state of the health of a structure, namely man made, like mistakes in the construction, traffic, heavy loads on the structures, explosions, environmental impacts like wind loads, humidity, chemical reactions, temperature changes and saltiness, and natural hazards like earthquakes and landslides. Monitoring the health of a structure provides the ability to anticipate structural failures and secure the safe use of buildings especially those of public services. This work reviews the state of the art and the challenges of a wireless Structural Health Monitoring (WiSHM). Literature review reveals that although there is significant evolution in wireless structural health monitoring, in many cases, monitoring by itself is not enough to predict when a structure becomes inappropriate and/or unsafe for use, and the damage or low durability of a structure cannot be revealed (Chintalapudi, et al., 2006; Ramos, Aguilar, & Lourenço, 2011). Several features and specifications of WiSHM like wireless sensor networking, reliability and autonomy of sensors, algorithms of data transmission and analysis should still be evolved and improved in order to increase the predictive effectiveness of the SHM (Jinping Ou & Hui Li, 2010; Lu & Loh, 2010) . Acknowledgments This work was supported in part by the ARCHEMEDES III Program of the Ministry of Education of Greece and the European Union in the framework of the project entitled «Interdisciplinary Multi-Scale Research of Earthquake Physics and Seismotectonics at the front of the Hellenic Arc (IMPACT-ARC) ».

  17. Taking the Pulse: Monitoring the Quality and Progress of Internationalization, Including Tracking Measures. CBIE Research Millennium Series No. 2

    Science.gov (United States)

    Knight, Jane

    2000-01-01

    Internalization of higher education will be remembered as one of the major challenges and accomplishments of the last two decades. This paper introduces the concept of qualitative and quantitative tracking measures to enable a monitoring of progress and quality toward specified objects or targets. The purpose of this paper is: (1) to emphasize the…

  18. Integrated system of structural health monitoring and intelligent management for a cable-stayed bridge.

    Science.gov (United States)

    Chen, Bin; Wang, Xu; Sun, Dezhang; Xie, Xu

    2014-01-01

    It is essential to construct structural health monitoring systems for large important bridges. Zhijiang Bridge is a cable-stayed bridge that was built recently over the Hangzhou Qiantang River (the largest river in Zhejiang Province). The length of Zhijiang Bridge is 478 m, which comprises an arched twin-tower space and a twin-cable plane structure. As an example, the present study describes the integrated system of structural health monitoring and intelligent management for Zhijiang Bridge, which comprises an information acquisition system, data management system, evaluation and decision-making system, and application service system. The monitoring components include the working environment of the bridge and various factors that affect bridge safety, such as the stress and strain of the main bridge structure, vibration, cable force, temperature, and wind speed. In addition, the integrated system includes a forecasting and decision-making module for real-time online evaluation, which provides warnings and makes decisions based on the monitoring information. From this, the monitoring information, evaluation results, maintenance decisions, and warning information can be input simultaneously into the bridge monitoring center and traffic emergency center to share the monitoring data, thereby facilitating evaluations and decision making using the system.

  19. 32 CFR 37.710 - What standards do I include for purchasing systems of nonprofit organizations?

    Science.gov (United States)

    2010-07-01

    ... systems of nonprofit organizations? 37.710 Section 37.710 National Defense Department of Defense OFFICE OF... standards do I include for purchasing systems of nonprofit organizations? (a) So as not to force system... governmental organization. (2) 32 CFR 32.40 through 32.49 if the participant is a nonprofit organization...

  20. Structural health monitoring system/method using electroactive polymer fibers

    Science.gov (United States)

    Scott-Carnell, Lisa A. (Inventor); Siochi, Emilie J. (Inventor)

    2013-01-01

    A method for monitoring the structural health of a structure of interest by coupling one or more electroactive polymer fibers to the structure and monitoring the electroactive responses of the polymer fiber(s). Load changes that are experienced by the structure cause changes in the baseline responses of the polymer fiber(s). A system for monitoring the structural health of the structure is also provided.

  1. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    Science.gov (United States)

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  2. Contraceptive efficacy of the personal hormone monitoring system Persona.

    Science.gov (United States)

    Trussell, J

    1999-07-01

    This is a commentary on the contraceptive effectiveness of the personal hormone-monitoring system Persona; it points out the various errors committed in computing method pregnancy rates. The modifications presented by Bonnar et al. on the incorrect procedure for computing method pregnancy rates are criticized as erroneous because the denominator includes cycles in which there is no risk of a method pregnancy according to the authors' algorithm for classifying pregnancy in an imperfect-use cycle. It is also claimed that the new exercise is a more complicated and less accurate way of computing for pregnancy rates by comparison with the simpler alternative. Since this new algorithm, used in the Persona system, is based on flawed logic, the annual risk of pregnancy is actually higher than the estimated 6% among women using Persona and having intercourse in each cycle except on red days.

  3. IEEE 802.11 ECG monitoring system.

    Science.gov (United States)

    Tejero-Calado, Juan; Lopez-Casado, Carmen; Bernal-Martin, Antonio; Lopez-Gomez, Miguel; Romero-Romero, Marco; Quesada, Guillermo; Lorca, Julio; Rivas, Ramon

    2005-01-01

    New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. This kind of devices favours at-home hospitalization, reducing the affluence to sanitary assistance centers to make routine controls. This fact causes a really favourable social impact, especially for elder people, rural-zone inhabitant, chronic patients and handicapped people. Furthermore, it offers new functionalities to physicians and will reduce the sanitary cost. Among these functionalities, biomedical signals can be sent to other devices (screen, PDA, PC...) or processing centers, without restricting the patients' mobility. The aim of this project is the development and implementation of a reduced size multi-channel electrocardiograph based on IEEE 802.11, which allows wireless monitoring of patients, and the insertion of the information into the TCP/IP Hospital network.

  4. Optimization of remediation strategies using vadose zone monitoring systems

    Science.gov (United States)

    Dahan, Ofer

    2016-04-01

    In-situ bio-remediation of the vadose zone depends mainly on the ability to change the subsurface hydrological, physical and chemical conditions in order to enable development of specific, indigenous, pollutants degrading bacteria. As such the remediation efficiency is much dependent on the ability to implement optimal hydraulic and chemical conditions in deep sections of the vadose zone. These conditions are usually determined in laboratory experiments where parameters such as the chemical composition of the soil water solution, redox potential and water content of the sediment are fully controlled. Usually, implementation of desired optimal degradation conditions in deep vadose zone at full scale field setups is achieved through infiltration of water enriched with chemical additives on the land surface. It is assumed that deep percolation into the vadose zone would create chemical conditions that promote biodegradation of specific compounds. However, application of water with specific chemical conditions near land surface dose not necessarily results in promoting of desired chemical and hydraulic conditions in deep sections of the vadose zone. A vadose-zone monitoring system (VMS) that was recently developed allows continuous monitoring of the hydrological and chemical properties of deep sections of the unsaturated zone. The VMS includes flexible time-domain reflectometry (FTDR) probes which allow continuous monitoring of the temporal variation of the vadose zone water content, and vadose-zone sampling ports (VSPs) which are designed to allow frequent sampling of the sediment pore-water and gas at multiple depths. Implementation of the vadose zone monitoring system in sites that undergoes active remediation provides real time information on the actual chemical and hydrological conditions in the vadose zone as the remediation process progresses. Up-to-date the system has been successfully implemented in several studies on water flow and contaminant transport in

  5. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    Science.gov (United States)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  6. Including natural systems into the system engineering process: benefits to spaceflight and beyond

    Science.gov (United States)

    Studor, George

    2014-03-01

    How did we get to the point where we don't have time to be inspired by the wonders of Nature? Our office walls, homes and city streets are so plain that even when we do escape to a retreat with nature all around us, we may be blind to its magnificence. Yet there are many who have applied what can be known of natural systems (NS) to create practical solutions, but often definite applications for them are lacking. Mimicry of natural systems is not only more possible than ever before, but the education and research programs in many major universities are churning out graduates with a real appreciation for Nature's complex integrated systems. What if these skills and perspectives were employed in the teams of systems engineers and the technology developers that support them to help the teams think "outside-the-box" of manmade inventions? If systems engineers (SE) and technology developers regularly asked the question, "what can we learn from Nature that will help us?" as a part of their processes, they would discover another set of potential solutions. Biomimicry and knowledge of natural systems is exploding. What does this mean for systems engineering and technology? Some disciplines such as robotics and medical devices must consider nature constantly. Perhaps it's time for all technology developers and systems engineers to perceive natural systems experts as potential providers of the technologies they need.

  7. Test of GBAS Integrity Monitoring System Using GPS Simulator

    Institute of Scientific and Technical Information of China (English)

    Yun Young-sun; Park Sung-min; Kee Chang-don

    2003-01-01

    In recent years, many countries are developing aircraft navigation systems using GNSS(Global Navigation Satellite System),because GNSS has many technical and economic benefits. International organizations as ICAO(International Civil Aviation Organization) and RTCA(Radio Technical Commission for Aeronautics) set up international standards of GBAS(Ground Based Augmentation System)using GNSS and recommend countries to develop GBAS that is based on the standards. To go with the international stream, Korea Airport Cooperation has also developed GBAS. For evaluating the system,KAC and Seoul National University have performed flight tests of the developed GBAS several times and have concluded that the system has good accuracy enough to be used in aircrafts. At that time, the purpose of tests was focused on accuracy of GBAS. But integrity of the system which is important for safety of aircrafts was not tested sufficiently,because it is impossible to make erroneous situations of real GPS signals. So, at this time, we used GPS simulator which can generate GPS signals with satellite failure scenarios. The GPS simulator used in this test generates GPS signals by the scenarios organized in advance.The scenarios can include pseudorange and carrier phase error, parity error and etc. So we organized several scenarios which can includes potential errors of GPS signals and many possible cases for testing the system effectively and accurately. And we tested integrity function of the GBAS system by using GPS signals generated by the simulator.This paper introduces the implemented integrity monitoring system and algorithms used in the tests. And it describes the scenarios of satellite failure. Finally, this paper shows the results of tests.

  8. The measurement procedure in the SEMONT monitoring system.

    Science.gov (United States)

    Djuric, Nikola; Kljajic, Dragan; Kasas-Lazetic, Karolina; Bajovic, Vera

    2014-03-01

    The measurement procedure of the open area in situ electric field strength is presented, acquiring the real field data for testing of the Serbian electromagnetic field monitoring network (SEMONT) and its Internet portal. The SEMONT monitoring system introduces an advanced approach of wireless sensor network utilization for the continuous supervision of overall and cumulative level of electromagnetic field over the observed area. The aim of the SEMONT system is to become a useful tool for the national and municipal agencies for the environmental protection, regarding the electromagnetic pollution monitoring and the exposure assessment of the general population. Considering the public concern on the potentially harmful effects of the long-term exposure to electromagnetic radiation, as well as the public transparency principle that is incorporated into the Serbian law on non-ionizing radiation protection, the SEMONT monitoring system is designed for the long-term continuous monitoring, presenting real-time measurement results, and corresponding exposure assessment over the public Internet network.

  9. A Wireless Monitoring System for Cracks on the Surface of Reactor Containment Buildings.

    Science.gov (United States)

    Zhou, Jianguo; Xu, Yaming; Zhang, Tao

    2016-06-14

    Structural health monitoring with wireless sensor networks has been increasingly popular in recent years because of the convenience. In this paper, a real-time monitoring system for cracks on the surface of reactor containment buildings is presented. Customized wireless sensor networks platforms are designed and implemented with sensors especially for crack monitoring, which include crackmeters and temperature detectors. Software protocols like route discovery, time synchronization and data transfer are developed to satisfy the requirements of the monitoring system and stay simple at the same time. Simulation tests have been made to evaluate the performance of the system before full scale deployment. The real-life deployment of the crack monitoring system is carried out on the surface of reactor containment building in Daya Bay Nuclear Power Station during the in-service pressure test with 30 wireless sensor nodes.

  10. A guidebook for the operation and maintenance of HANARO seismic monitoring analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, Doo Byung; Kim, Hyung Kyoo

    2003-09-01

    Systems and structures related to HANARO safety are classified as seismic category I. Since 1995, the seismic monitoring system has been utilized for monitoring an earthquake at the HANARO site. The existing seismic monitoring system consists of field sensors and monitoring panel. The analog-type monitoring system with magnetic tape recorder is out-of-date model. In addition, the disadvantage of the existing system is that it does not include signal-analyzing equipment. Therefore, we have improved the analog seismic monitoring system into a new digital Seismic Monitoring Analysis System(SMAS) that can offer precise and detail information of the earthquake signals. This newly developed SMAS is operating at the HANARO instrument room to acquire and analyze the signal of an earthquake. This document is a guidebook for the operation and maintenance of the SMAS. The first chapter gives an outline of the SMAS. The second chapter describes functional capability and specification of the hardware. Chapters 3 and 4 describe starting procedure of the SMAS and how to operate the seismic monitoring program, respectively. Chapter 5 illustrates the seismic analysis algorithm used in the SMAS. The way of operating the seismic analysis program is described in chapter 6. Chapter 7 illustrates the calibration procedure for data acquisition module. Chapter 8 describes the symptoms of common malfunctions and its countermeasure suited to the occasions.

  11. Crab: A Dashboard System for Monitoring Archiving Tasks

    Science.gov (United States)

    Bell, G.; Jenness, T.; Agarwal, A.

    2013-10-01

    In order to make the large number of cron jobs required to perform data archiving tasks at the Joint Astronomy Centre more manageable, we have designed and implemented a dashboard system for monitoring their progress. The status of all of the tasks can be monitored on the dashboard's web interface, and via consolidated notification emails.

  12. [Fetal ECG monitoring system based on MCU processing].

    Science.gov (United States)

    Hu, Gang; Chen, Wei; Xie, Xicheng; Zhang, Hao

    2004-12-01

    In order to monitor the fetus in labor, the signal characteristic from fetal scalp electrode is researched, An adaptation algorithm and a peak to peak detecting technology are adopted in signal processing, and an adaptation gain control method is used to eliminate disturber from base-line shift. A fetal ECG monitoring system is designed on the basis of C8051F020 MCU.

  13. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  14. B190 computer controlled radiation monitoring and safety interlock system

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, D L; Fields, W F; Gittins, D E; Roberts, M L

    1998-08-01

    The Center for Accelerator Mass Spectrometry (CAMS) in the Earth and Environmental Sciences Directorate at Lawrence Livermore National Laboratory (LLNL) operates two accelerators and is in the process of installing two new additional accelerators in support of a variety of basic and applied measurement programs. To monitor the radiation environment in the facility in which these accelerators are located and to terminate accelerator operations if predetermined radiation levels are exceeded, an updated computer controlled radiation monitoring system has been installed. This new system also monitors various machine safety interlocks and again terminates accelerator operations if machine interlocks are broken. This new system replaces an older system that was originally installed in 1988. This paper describes the updated B190 computer controlled radiation monitoring and safety interlock system.

  15. The participatory design of a performance oriented monitoring and evaluation system in an international development environment.

    Science.gov (United States)

    Guerra-López, Ingrid; Hicks, Karen

    2015-02-01

    This article illustrates the application of the impact monitoring and evaluation process for the design and development of a performance monitoring and evaluation framework in the context of human and institutional capacity development. This participative process facilitated stakeholder ownership in several areas including the design, development, and use of a new monitoring and evaluation system, as well their targeted results and accomplishments through the use of timely performance data gathered through ongoing monitoring and evaluation. The process produced a performance indicator map, a comprehensive monitoring and evaluation framework, and data collection templates to promote the development, implementation, and sustainability of the monitoring and evaluation system of a farmer's trade union in an African country. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Improved Stochastic Subspace System Identification for Structural Health Monitoring

    Science.gov (United States)

    Chang, Chia-Ming; Loh, Chin-Hsiung

    2015-07-01

    Structural health monitoring acquires structural information through numerous sensor measurements. Vibrational measurement data render the dynamic characteristics of structures to be extracted, in particular of the modal properties such as natural frequencies, damping, and mode shapes. The stochastic subspace system identification has been recognized as a power tool which can present a structure in the modal coordinates. To obtain qualitative identified data, this tool needs to spend computational expense on a large set of measurements. In study, a stochastic system identification framework is proposed to improve the efficiency and quality of the conventional stochastic subspace system identification. This framework includes 1) measured signal processing, 2) efficient space projection, 3) system order selection, and 4) modal property derivation. The measured signal processing employs the singular spectrum analysis algorithm to lower the noise components as well as to present a data set in a reduced dimension. The subspace is subsequently derived from the data set presented in a delayed coordinate. With the proposed order selection criteria, the number of structural modes is determined, resulting in the modal properties. This system identification framework is applied to a real-world bridge for exploring the feasibility in real-time applications. The results show that this improved system identification method significantly decreases computational time, while qualitative modal parameters are still attained.

  17. Coal mine gas monitoring system based on wireless sensor network

    Institute of Scientific and Technical Information of China (English)

    WANG Jian; WANG Ru-lin; WANG Xue-min; SHEN Chuan-he

    2007-01-01

    Based on the nowadays'condition.it is urgent that the gas detection cable communication system must be replaced by the wireless communication systems.The wireless sensors distributed in the environment can achieve the intelligent gas monitoring system.Apply with multilayer data fuse to design working tactics,and import the artificial neural networks to analyze detecting result.The wireless sensors system communicates with the controI center through the optical fiber cable.All the gas sensor nodes distributed in coal mine are combined into an intelligent,flexible structure wireless network system.forming coal mine gas monitoring system based on wireless sensor network.

  18. A Development of Empirical Models for Equipment Condition Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Song Kyu; Baik, Se Jin [KEPCO Engineering and Construction Company, Daejeon (Korea, Republic of); An, Sang Ha [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2010-10-15

    A great deal of effort is recently put into on-line monitoring (OLM), specially using empirical model to detect earlier the fault of components or the calibration reduction/extension of instrument. The empirical model is constructed with historical data obtained during operation and it mainly relies on regression techniques. Various models are used in OLM and the role of models is to describe the relation among signals that have been collected. Ultimate goal of empirical models is to best estimate parameter as soon as possible close to actual value. Typically some of the historical data are used for model training, and some data are used for verification and assessment of model performance. Several different models for OLM of nuclear power systems are currently being used. Examples include the ANL Multivariate State Estimation Techniques (MSET) used in EPI center of SmartSignal, the expert state estimation engine (ESEE) used in SureSense software of Expert Microsystems, Process Evaluation and Analysis by Neural Operators (PEANO) OECD of Halden Reactor Project and linear regression model used in RCP seal integrity monitoring system (SIMON) of KEPCO E and C

  19. Intelligent monitoring-based safety system of massage robot

    Institute of Scientific and Technical Information of China (English)

    胡宁; 李长胜; 王利峰; 胡磊; 徐晓军; 邹雲鹏; 胡玥; 沈晨

    2016-01-01

    As an important attribute of robots, safety is involved in each link of the full life cycle of robots, including the design, manufacturing, operation and maintenance. The present study on robot safety is a systematic project. Traditionally, robot safety is defined as follows: robots should not collide with humans, or robots should not harm humans when they collide. Based on this definition of robot safety, researchers have proposed ex ante and ex post safety standards and safety strategies and used the risk index and risk level as the evaluation indexes for safety methods. A massage robot realizes its massage therapy function through applying a rhythmic force on the massage object. Therefore, the traditional definition of safety, safety strategies, and safety realization methods cannot satisfy the function and safety requirements of massage robots. Based on the descriptions of the environment of massage robots and the tasks of massage robots, the present study analyzes the safety requirements of massage robots; analyzes the potential safety dangers of massage robots using the fault tree tool; proposes an error monitoring-based intelligent safety system for massage robots through monitoring and evaluating potential safety danger states, as well as decision making based on potential safety danger states; and verifies the feasibility of the intelligent safety system through an experiment.

  20. An Integrated Health Monitoring System for Fission Surface Power

    Science.gov (United States)

    Hashemian, H. M.; Shumaker, B. D.; McCulley, J. R.; Morton, G. W.

    Based on such criteria as safety and mission success, programmatic risk, affordability, and extensibility/flexibility, the National Aeronautics and Space Administration (NASA) has chosen fission surface power (FSP) as the primary energy source for building a sustained human presence on the Moon, exploring Mars, and extremely long-duration space missions. The current benchmark FSP system has a mission life of at least 8 years during which time there is no opportunity for repair, sensor calibrations, or periodic maintenance tasks that are normally performed on terrestrial-based nuclear power plants during scheduled outages. Current technology relies heavily on real-time human interaction, monitoring and control. However; due to the long communication times between the Earth and Moon, or Mars, real-time human control is not possible, resulting in a critical need to develop autonomous health monitoring technology for FSP systems.This paper describes the design and development of an autonomous health monitoring system that will (1) provide on-line calibration monitoring, (2) reduce uncertainties in sensor measurements, and (3) provide sensor validation and fault detection capabilities for the control systems of various FSP subsystems. The health monitoring system design integrates a number of signal processing algorithms and techniques such as cross-calibration, empirical modeling using neural networks, and physical modeling under a modular signal processing platform that will enable robust sensor and system monitoring without the need for human interaction. Prototypes of the health monitoring system have been tested and validated on data acquired from preliminary subsystem testing of NASA's FSP Technology Demonstration Unit (TDU) as well as simulated laboratory data. Results from this testing have demonstrated the utility and benefits that such autonomous health monitoring systems can provide to FSP subsystems and other potential applications within NASA such as launch

  1. Real-time health monitoring of civil infrastructure systems in Colombia

    Science.gov (United States)

    Thomson, Peter; Marulanda Casas, Johannio; Marulanda Arbelaez, Johannio; Caicedo, Juan

    2001-08-01

    Colombia's topography, climatic conditions, intense seismic activity and acute social problems place high demands on the nations deteriorating civil infrastructure. Resources that are available for maintenance of the road and railway networks are often misdirected and actual inspection methods are limited to a visual examination. New techniques for inspection and evaluation of safety and serviceability of civil infrastructure, especially bridges, must be developed. Two cases of civil structures with health monitoring systems in Colombia are presented in this paper. Construction of the Pereria-Dos Quebradas Viaduct was completed in 1997 with a total cost of 58 million dollars, including 1.5 million dollars in health monitoring instrumentation provided and installed by foreign companies. This health monitoring system is not yet fully operational due to the lack of training of national personnel in system operation and extremely limited technical documentation. In contrast to the Pereria-Dos Quebradas Viaduct monitoring system, the authors have proposed a relatively low cost health monitoring system via telemetry. This system has been implemented for real-time monitoring of accelerations of El Hormiguero Bridge spanning the Cauca River using the Colombian Southwest Earthquake Observatory telemetry systems. This two span metallic bridge, located along a critical road between the cities of Puerto Tejada and Cali in the Cauca Valley, was constructed approximately 50 years ago. Experiences with this system demonstrate how effective low cost systems can be used to remotely monitor the structural integrity of deteriorating structures that are continuously subject to high loading conditions.

  2. Generic effluent monitoring system certification for AP-40 exhauster stack

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, J.A.; Davis, W.E.; Bussell, J.H.; Maughan, A.D.

    1997-09-01

    Tests were conducted to verify that the Generic Effluent Monitoring System (GEMS), as applied to the AP-40 exhauster stack, meets all applicable regulatory performance criteria for air sampling systems at nuclear facilities. These performance criteria address both the suitability of the air sampling probe location and the transport of the sample to the collection devices. The criteria covering air sampling probe location ensure that the contaminants in the stack are well mixed with the airflow at the probe location such that the extracted sample represents the whole. The sample transport criteria ensure that the sampled contaminants are quantitatively delivered to the collection device. The specific performance criteria are described in detail in the report. The tests demonstrated that the GEMS/AP-40 system meets all applicable performance criteria. The contaminant mixing tests were conducted by Pacific Northwest National Laboratory (PNNL) at the wind tunnel facility, 331-H Building, using a mockup of the actual stack. The particle sample transport tests were conducted by PNNL at the Numatec Hanford Company`s 305 Building. The AP-40 stack is typical of several 10-in. diameter stacks that discharge the filtered ventilation air from tank farms at the U.S. Department of Energy`s Hanford Site in Richland, Washington. The GEMS design features a probe with a single shrouded sampling nozzle, a sample delivery line, and sample collection system. The collection system includes a filter holder to collect the sample of record and an in-line detector head and filter for monitoring beta radiation-emitting particles. Unrelated to the performance criteria, it was found that the record sample filter holder exhibited symptoms of sample bypass around the particle collection filter. This filter holder should either be modified or replaced with a different type. 10 refs., 8 figs., 6 tabs.

  3. The development of remote wireless radiation dose monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin-woo [KAERI - Korea Atomic Energy Research Institute, Jeongup-si (Korea, Republic of); Chonbuk National University, Jeonjoo-Si (Korea, Republic of); Jeong, Kyu-hwan [KINS - Korea Institute of Nuclear Safety, Daejeon-Si (Korea, Republic of); Kim, Jong-il [Chonbuk National University, Jeonjoo-Si (Korea, Republic of); Im, Chae-wan [REMTECH, Seoul-Si (Korea, Republic of)

    2015-07-01

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

  4. Operation of International Monitoring System Network

    Science.gov (United States)

    Nikolova, Svetlana; Araujo, Fernando; Aktas, Kadircan; Malakhova, Marina; Otsuka, Riyo; Han, Dongmei; Assef, Thierry; Nava, Elisabetta; Mickevicius, Sigitas; Agrebi, Abdelouaheb

    2015-04-01

    The IMS is a globally distributed network of monitoring facilities using sensors from four technologies: seismic, hydroacoustic, infrasound and radionuclide. It is designed to detect the seismic and acoustic waves produced by nuclear test explosions and the subsequently released radioactive isotopes. Monitoring stations transmit their data to the IDC in Vienna, Austria, over a global private network known as the GCI. Since 2013, the data availability (DA) requirements for IMS stations account for quality of the data, meaning that in calculation of data availability data should be exclude if: - there is no input from sensor (SHI technology); - the signal consists of constant values (SHI technology); Even more strict are requirements for the DA of the radionuclide (particulate and noble gas) stations - received data have to be analyzed, reviewed and categorized by IDC analysts. In order to satisfy the strict data and network availability requirements of the IMS Network, the operation of the facilities and the GCI are managed by IDC Operations. Operations has following main functions: - to ensure proper operation and functioning of the stations; - to ensure proper operation and functioning of the GCI; - to ensure efficient management of the stations in IDC; - to provide network oversight and incident management. At the core of the IMS Network operations are a series of tools for: monitoring the stations' state of health and data quality, troubleshooting incidents, communicating with internal and external stakeholders, and reporting. The new requirements for data availability increased the importance of the raw data quality monitoring. This task is addressed by development of additional tools for easy and fast identifying problems in data acquisition, regular activities to check compliance of the station parameters with acquired data by scheduled calibration of the seismic network, review of the samples by certified radionuclide laboratories. The DA for the networks of

  5. Engineering considerations for corrosion monitoring of gas gathering pipeline systems

    Energy Technology Data Exchange (ETDEWEB)

    Braga, T.G.; Asperger, R.G.

    1987-01-01

    Proper corrosion monitoring of gas gathering pipelines requires a system review to determine the appropriate monitor locations and types of monitoring techniques. This paper develops and discusses a classification of conditions such as flow regime and gas composition. Also discussed are junction categories which, for corrosion monitoring, need to be considered from two points of view. The first is related to fluid flow in the line and the second is related corrosion inhibitor movement along the pipeline. The appropriate application of the various monitoring techniques such as coupons, hydrogen detectors, electrical resistance probe and linear polarization probes are discussed in relation to flow regime and gas composition. Problems caused by semi-conduction from iron sulfide are considered. Advantages and disadvantages of fluid gathering methods such as pots and flow-through drips are discussed in relation to their reliability as on-line monitoring locations.

  6. Reduced Toxicity Fuel Satellite Propulsion System Including Catalytic Decomposing Element with Hydrogen Peroxide

    Science.gov (United States)

    Schneider, Steven J. (Inventor)

    2002-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster, whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  7. 75 FR 448 - In the Matter of: Certain Authentication Systems, Including Software and Handheld Electronic...

    Science.gov (United States)

    2010-01-05

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION In the Matter of: Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION: Institution...

  8. Design of smart neonatal health monitoring system using SMCC.

    Science.gov (United States)

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  9. US8,994,532 "Data Center Equipment Location and Monitoring System"

    DEFF Research Database (Denmark)

    2014-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...

  10. Wireless data management system for environmental monitoring in livestock buildings

    Directory of Open Access Journals (Sweden)

    James Gray

    2017-03-01

    Full Text Available The impact of air quality on the health, welfare and productivity of livestock needs to be considered, especially when livestock are kept in enclosed buildings. The monitoring of such environmental factors allows for the development of appropriate strategies to reduce detrimental effects of sub-optimal air quality on the respiratory health of both livestock and farmers. In 2009, an environmental monitoring system was designed, developed and tested that allowed for the monitoring of a number of airborne pollutants. One limitation of the system was the manual collection of logged data from each unit. This paper identifies limitations of the current environmental monitoring system and suggests a range of networking technologies that can be used to increase usability. Consideration is taken for the networking of environmental monitoring units, as well as the collection of recorded data. Furthermore, the design and development of a software system that is used to collate and store recorded environmental data from multiple farms is explored. In order to design such a system, simplified software engineering processes and methodologies have been utilised. The main steps taken in order to complete the project were requirements elicitation with clients, requirements analysis, system design, implementation and finally testing. The outcome of the project provided a potential prototype for improving the environmental monitoring system and analysis informing the benefit of the implementation.

  11. Vulnerability analysis for design of bridge health monitoring system

    Science.gov (United States)

    Sun, L. M.; Yu, G.

    2010-03-01

    The recent engineering implementation of health monitoring system for long span bridges show difficulties for precisely assessing structural physical condition as well as for accurately alarming on structural damages, although hundreds of sensors were installed on a structure and a great amount of data were collected from the monitoring system. The allocation of sensors and the alarming algorithm are still two of the most important tasks to be considered when designing the structural health monitoring system. Vulnerability, in its original meaning, is the system susceptibility to local damage. For a structural system, the vulnerability can thus be regarded as structural performance susceptibility to local damage of structure. The purpose of this study is to propose concepts and methods of structural vulnerability for determining monitoring components which are more vulnerable than others and the corresponding warning threshold once the damages occur. The structural vulnerability performances to various damage scenarios depend upon structural geometrical topology, loading pattern on the structure and the degradation of component performance. A two-parameters structural vulnerability evaluation method is proposed in this paper. The parameters are the damage consequence and the relative magnitude of the damage scenarios to the structural system, respectively. Structural vulnerability to various damage scenarios can be regarded as the tradeoff between the two parameters. Based on the results of structural vulnerability analysis, the limited structural information from health monitoring can be utilized efficiently. The approach of the design of bridge health monitoring system is illustrated for a cable-stayed bridge.

  12. Project W-420 Stack Monitoring system upgrades conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    TUCK, J.A.

    1998-11-06

    This document describes the scope, justification, conceptual design, and performance of Project W-420 stack monitoring system upgrades on six NESHAP-designated, Hanford Tank Farms ventilation exhaust stacks.

  13. Feed the Future Monitoring System Aggregate Data 2011-2014

    Data.gov (United States)

    US Agency for International Development — The Feed the Future Monitoring System (FTFMS) is part of an interagency effort to consolidate U.S. Government (USG) reporting on Feed the Future activities. FTFMS...

  14. Novel Real-Time Flight Envelope Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an aircraft flight envelope monitoring system that will provide real-time in-cockpit estimations of aircraft flight envelope boundaries,...

  15. Novel Real-Time Flight Envelope Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an aircraft flight envelope monitoring system that will provide real-time in-cockpit estimations of aircraft flight envelope boundaries....

  16. A Framework for Systematic Benchmarking of Monitoring and Diagnostic Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — In this paper, we present an architecture and a formal framework to be used for systematic benchmarking of monitoring and diagnostic systems and for producing...

  17. Dealing with distributed intelligence in monitoring and control systems

    CERN Document Server

    McLaren, R A

    1981-01-01

    The European Hybrid Spectrometer is built up of many individual detectors, each having widely varying monitoring and control requirements. With the advent of cheap microprocessor systems a shift from the concept of a single monitoring and control computer to that of distributed intelligent controllers has been economically feasible. A detector designer can now thoroughly test and debug a complete monitoring and control system on a local, dedicated micro-computer, while during operation, the central computer can be relieved of many simple repetitive tasks. Rapidly, however, it has become obvious that the designers of these systems have to take into account the final operational environment and build into both the hardware and software, features allowing easy integration into a central monitoring and control chain. In addition, the problems of maintenance and eventual modification have to be taken into consideration early in the development. Examples of currently operational systems will be briefly described to...

  18. Novel Non-Intrusive Vibration Monitoring System for Turbopumps Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ASRI proposes to develop an advanced and commercially viable Non-Intrusive Vibration Monitoring System (NI-VMS) which can provide effective on-line/off-line engine...

  19. Passive Wireless Sensor System for Structural Health Monitoring Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Albido proposes to develop a Passive Wireless Sensor System for Structural Health Monitoring capable of measuring high-bandwidth temperature and strain of space and...

  20. Research of Embedded Tower Crane Monitoring System Based on FCS

    Directory of Open Access Journals (Sweden)

    Xijian Zheng

    2013-09-01

    Full Text Available To compensate for the lack of traditional safety limit device of tower crane, a design scheme of embedded tower crane intelligent monitoring system based on Fieldbus Control System was proposed. By this, online collection and transmission of tower crane real-time conditions were achieved, which could effectively improve the reliability and anti-interference of the system. Embedded development technology was used to build ARM-based master control platform. Embedded Linux cross-compiler environment was also built. Combining with embedded programming software, human-computer interaction interface of tower crane intelligent monitoring system was built, storage and display of tower crane’s online parameters were also realized. The use of the technology has opened up a new field of tower crane condition monitoring application. The research of this paper may provide reference for tower crane safety monitoring and fault diagnosing.

  1. Cascade Controller Including Back-stepping for Hydraulic-Mechanical Systems

    DEFF Research Database (Denmark)

    Choux, Martin; Hovland, Geir; Blanke, Mogens

    2012-01-01

    Development of a cascade controller structure including adaptive backstepping for a nonlinear hydraulic-mechanical system is considered in this paper where a dynamic friction (LuGre) model is included to obtain the necessary accuracy. The paper compares the performance of two variants of an adapt...

  2. High resolution monitoring system for IRE stack releases.

    Science.gov (United States)

    Deconninck, B; De Lellis, C

    2013-11-01

    The main activity of IRE (Institute for Radio-Element) is radioisotope production of bulk (99)Mo and (131)I for medical application (diagnosis and therapy). Those isotopes are chemically extracted from HEU (High Enriched Uranium) targets activated in reactors. During this process, fission products are released from the targets, including noble gases isotopes (Xe and Kr). Like any nuclear plant, IRE has release limits which are given by the Belgium authority and moreover IRE is in the process of continuously reducing the level of its releases. To achieve this mission, the need of an accurate tool is necessary and IRE has developed a specific monitoring system using a high resolution detector in order to identify and accurately estimate its gaseous releases. This system has a continuous air sampling system in the plant main stack. The sampled gases cross charcoal cartridges where they are slowed down and concentrated for higher detection efficiency. In front of those cartridges is installed an HPGe detector with a detection chain connected to a specific analysis system allowing on-line spectrum analysis. Each isotope can be separately followed without interferences, especially during the production process where high activity can be released. Due to its conception, the system also allows to measure iodine isotopes by integration on the charcoal cartridges. This device is of great help for accurately estimate IRE releases and to help for understanding specific releases and their origin in the production or maintenance process.

  3. IPTV-RM: A Resources Monitoring Architecture for P2P IPTV Systems

    OpenAIRE

    2012-01-01

    Resources monitoring is an important problem of the overall efficient usage and control of P2P IPTV systems. The resources of IPTV can include all distributing servers, programs and peers. Several researches have tried to address this issue, but most of them illuminated P2P traffic characterization, identification and user behavior. The main contributions of this paper are twofold. Firstly, a resources monitoring architecture for P2P IPTV systems, IPTV-RM, was presented based on previous work...

  4. Method for pulse control in a laser including a stimulated brillouin scattering mirror system

    Science.gov (United States)

    Dane, C. Brent; Hackel, Lloyd; Harris, Fritz B.

    2007-10-23

    A laser system, such as a master oscillator/power amplifier system, comprises a gain medium and a stimulated Brillouin scattering SBS mirror system. The SBS mirror system includes an in situ filtered SBS medium that comprises a compound having a small negative non-linear index of refraction, such as a perfluoro compound. An SBS relay telescope having a telescope focal point includes a baffle at the telescope focal point which blocks off angle beams. A beam splitter is placed between the SBS mirror system and the SBS relay telescope, directing a fraction of the beam to an alternate beam path for an alignment fiducial. The SBS mirror system has a collimated SBS cell and a focused SBS cell. An adjustable attenuator is placed between the collimated SBS cell and the focused SBS cell, by which pulse width of the reflected beam can be adjusted.

  5. Radiation Monitoring System of 30 MeV Cyclotron

    Science.gov (United States)

    Lee, Jin-Woo; Hur, Min-Goo; Jeong, Gyosung; Kim, Jongil

    2017-09-01

    A state-of-the-art radiation monitoring system was implemented at KAERI for a 30-MeV cyclotron. This system consists of several types of radiation measuring systems for ambient dose equivalent rate measurements of outside photon and neutron areas as well as inside the cyclotron, and monitors the alpha and beta particulates released from a stack, as well as the results of worker contamination at the portal of the cyclotron. In addition, an automatic alarm system is also mounted if there are alarms in the measuring systems.

  6. Systems and Methods for Fabricating Objects Including Amorphous Metal Using Techniques Akin to Additive Manufacturing

    Science.gov (United States)

    Hofmann, Douglas (Inventor)

    2017-01-01

    Systems and methods in accordance with embodiments of the invention fabricate objects including amorphous metals using techniques akin to additive manufacturing. In one embodiment, a method of fabricating an object that includes an amorphous metal includes: applying a first layer of molten metallic alloy to a surface; cooling the first layer of molten metallic alloy such that it solidifies and thereby forms a first layer including amorphous metal; subsequently applying at least one layer of molten metallic alloy onto a layer including amorphous metal; cooling each subsequently applied layer of molten metallic alloy such that it solidifies and thereby forms a layer including amorphous metal prior to the application of any adjacent layer of molten metallic alloy; where the aggregate of the solidified layers including amorphous metal forms a desired shape in the object to be fabricated; and removing at least the first layer including amorphous metal from the surface.

  7. Integrated electronic system for ultrasonic structural health monitoring

    OpenAIRE

    Ruiz González, Mariano; Monje, Pedro María; Casado, Luciano; Aranguren, Gerardo; Cokonaj, Valerijan; Barrera Lopez de Turiso, Eduardo

    2012-01-01

    A fully integrated on-board electronic system that can perform in-situ structural health monitoring (SHM) of aircraft?s structures using specifically designed equipment for SHM based on guided wave ultrasonic method or Lamb waves? method is introduced. This equipment is called Phased Array Monitoring for Enhanced Life Assessment (PAMELA III) and is an essential part of overall PAMELA SHM? system. PAMELA III can generate any kind of excitation signals, acquire the response signals that propaga...

  8. A Remote Real-Time Monitoring System for Power Quality

    Institute of Scientific and Technical Information of China (English)

    黄治清; 贺建闽

    2003-01-01

    An introduction is made to the composition, design method and engineering application of a remote real-time monitoring system of power quality in substations based on internet. With virtual instrument and network technique adopted, this system is characterized by good real-time property, high reliability, plentiful functions, and so on. It also can be used to monitor the load of a substation, such as electric locomotives.

  9. Dedicated monitoring and machinery protection systems on reciprocating compressors

    Energy Technology Data Exchange (ETDEWEB)

    Grande, Alvaro; Wenisch, Markus [Hoerbiger Ventilwerke GmbH and Co KG, Wien (Austria); Jacobs, Denis [HOERBIGER do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    Growing demands on reciprocating compressors (recips) in the process gas industry require particular solutions for machinery protection and performance monitoring systems. Compared to rotating equipment, monitoring systems for recips have to consider the special mechanical and physical characteristics, such as oscillating masses, variable vibration behaviour and varying operating conditions. Furthermore, they provide valuable information about the performance of cylinder related components allowing the operator the optimization of efficiency and availability, and therefore increase production. (author)

  10. Low-cost control of discontinuous systems including impacts and friction

    OpenAIRE

    Svahn, Fredrik

    2007-01-01

    For a successful design of an engineering system it is essential to pay careful attention to its dynamic response. This is particularly true, in the case of nonlinear systems, since they can exhibit very complex dynamic behaviour, including multiple co-existing stable solutions and chaotic motions, characterized by large sensitivity to initial conditions. In some systems nonlinear characteristics are desired and designed for, but in other cases they are unwanted and can cause fatigue and fail...

  11. Monitoring devices and systems for monitoring frequency hopping wireless communications, and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Derr, Kurt W.; Richardson, John G.

    2017-05-02

    Monitoring devices and systems comprise a plurality of data channel modules coupled to processing circuitry. Each data channel module of the plurality of data channel modules is configured to capture wireless communications for a selected frequency channel. The processing circuitry is configured to receive captured wireless communications from the plurality of data channel modules and to organize received wireless communications according to at least one parameter. Related methods of monitoring wireless communications are also disclosed.

  12. Advanced Pulse Oximetry System for Remote Monitoring and Management

    Directory of Open Access Journals (Sweden)

    Ju Geon Pak

    2012-01-01

    Full Text Available Pulse oximetry data such as saturation of peripheral oxygen (SpO2 and pulse rate are vital signals for early diagnosis of heart disease. Therefore, various pulse oximeters have been developed continuously. However, some of the existing pulse oximeters are not equipped with communication capabilities, and consequently, the continuous monitoring of patient health is restricted. Moreover, even though certain oximeters have been built as network models, they focus on exchanging only pulse oximetry data, and they do not provide sufficient device management functions. In this paper, we propose an advanced pulse oximetry system for remote monitoring and management. The system consists of a networked pulse oximeter and a personal monitoring server. The proposed pulse oximeter measures a patient’s pulse oximetry data and transmits the data to the personal monitoring server. The personal monitoring server then analyzes the received data and displays the results to the patient. Furthermore, for device management purposes, operational errors that occur in the pulse oximeter are reported to the personal monitoring server, and the system configurations of the pulse oximeter, such as thresholds and measurement targets, are modified by the server. We verify that the proposed pulse oximetry system operates efficiently and that it is appropriate for monitoring and managing a pulse oximeter in real time.

  13. CISN ShakeAlert Earthquake Early Warning System Monitoring Tools

    Science.gov (United States)

    Henson, I. H.; Allen, R. M.; Neuhauser, D. S.

    2015-12-01

    CISN ShakeAlert is a prototype earthquake early warning system being developed and tested by the California Integrated Seismic Network. The system has recently been expanded to support redundant data processing and communications. It now runs on six machines at three locations with ten Apache ActiveMQ message brokers linking together 18 waveform processors, 12 event association processes and 4 Decision Module alert processes. The system ingests waveform data from about 500 stations and generates many thousands of triggers per day, from which a small portion produce earthquake alerts. We have developed interactive web browser system-monitoring tools that display near real time state-of-health and performance information. This includes station availability, trigger statistics, communication and alert latencies. Connections to regional earthquake catalogs provide a rapid assessment of the Decision Module hypocenter accuracy. Historical performance can be evaluated, including statistics for hypocenter and origin time accuracy and alert time latencies for different time periods, magnitude ranges and geographic regions. For the ElarmS event associator, individual earthquake processing histories can be examined, including details of the transmission and processing latencies associated with individual P-wave triggers. Individual station trigger and latency statistics are available. Detailed information about the ElarmS trigger association process for both alerted events and rejected events is also available. The Google Web Toolkit and Map API have been used to develop interactive web pages that link tabular and geographic information. Statistical analysis is provided by the R-Statistics System linked to a PostgreSQL database.

  14. Jet engine nozzle exit configurations, including projections oriented relative to pylons, and associated systems and methods

    Science.gov (United States)

    Mengle, Vinod G. (Inventor); Thomas, Russell H. (Inventor)

    2012-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter. Projections near a support pylon and/or associated heat shield can have particular configurations, including greater flow immersion than other projections.

  15. Evaluating the Handling Qualities of Flight Control Systems Including Nonlinear Aircraft and System Dynamics

    Science.gov (United States)

    Lin, Raymond Chao

    The handling qualities evaluation of nonlinear aircraft systems is an area of concern in loss-of-control (LOC) prevention. The Get Transfer Function (GetTF) method was demonstrated for evaluating the handling qualities of flight control systems and aircraft containing nonlinearities. NASA's Generic Transport Model (GTM), a nonlinear model of a civilian jet transport aircraft, was evaluated. Using classical techniques, the stability, control, and augmentation (SCAS) systems were designed to control pitch rate, roll rate, and airspeed. Hess's structural pilot model was used to model pilot dynamics in pitch and roll-attitude tracking. The simulated task was simultaneous tracking of, both, pitch and roll attitudes. Eight cases were evaluated: 1) gain increase of pitch-attitude command signal, 2) gain increase of roll-attitude command signal, 3) gain reduction of elevator command signal, 4) backlash in elevator actuator, 5) combination 3 and 4 in elevator actuator, 6) gain reduction of aileron command signal, 7) backlash in aileron actuator, and 8) combination of 6 and 7 in aileron actuator. The GetTF method was used to estimate the transfer function approximating a linear relationship between the proprioceptive signal of the pilot model and the command input. The transfer function was then used to predict the handling qualities ratings (HQR) and pilot-induced oscillation ratings (PIOR). The HQR is based on the Cooper-Harper rating scale. In pitch-attitude tracking, the nominal aircraft is predicted to have Level 2* HQRpitch and 2 control and aircraft systems. A limited human-in-the-loop pitch tracking exercise was also conducted to validate the structural pilot model.

  16. Monitoring and control systems for low voltage networks; Sistemas de monitoramento e controle para circuitos reticulados de BT

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Douglas Alexandre de Andrade; Silva, Humberto A.P.; Grimoni, Jose Aquiles Baesso [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia; Pereira, Sergio Luiz [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Engenharia de Energia e Automacao Eletricas (PEA); Araujo Filho, Edival Demetrio de [Companhia Energetica de Brasilia (CEB), DF (Brazil)

    2005-09-15

    This paper approaches a solution presented to CEB (Companhia Energetica de Brasilia), oriented to the economic viability of a monitoring system to the CEB low voltage distribution network through the use of a joint platform network protector/monitoring. The project include the reliability and safety standards, making available monitoring data of the transformers and/or feeders and energy quality.

  17. Implementation of alarm system for vibration monitoring of KOMAC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub [KOMAC, Gyeongju (Korea, Republic of)

    2015-05-15

    For operating 100 MeV linac, Devices have to be operated in certain order. Thus malfunction of a device cause damage to linac and related devices. To protect linac, machine protect system (MPS) has been developed. The MPS protects the components by monitoring hardwired signals. When values of operating parameters go beyond or below limit, alarm will be generated and interlock system which stops related devices in certain sequence will run. Other factor, giving damage to linac is disaster. A strong vibration such as earthquake causes malfunction of devices and damage to linac. Against disaster, the monitoring system based on Experimental Physics and Industrial Control System (EPICS) was implemented. Configuration and Implementation of the monitoring system are presented and some preliminary results are reported. KOMAC implemented alarm system for a strong vibration and fire. Alarm is generated in unusual situation. Coping rapidly with situation, damages for Linac and related devices can be reduced.

  18. Promoting Social Network Awareness: A Social Network Monitoring System

    Science.gov (United States)

    Cadima, Rita; Ferreira, Carlos; Monguet, Josep; Ojeda, Jordi; Fernandez, Joaquin

    2010-01-01

    To increase communication and collaboration opportunities, members of a community must be aware of the social networks that exist within that community. This paper describes a social network monitoring system--the KIWI system--that enables users to register their interactions and visualize their social networks. The system was implemented in a…

  19. 47 CFR 73.1400 - Transmission system monitoring and control.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmission system monitoring and control. 73... be accomplished by either: (i) Direct supervision and control of transmission system parameters by a person at the transmitter site; or (ii) Remote control of the transmission system by a person at the main...

  20. Promoting Social Network Awareness: A Social Network Monitoring System

    Science.gov (United States)

    Cadima, Rita; Ferreira, Carlos; Monguet, Josep; Ojeda, Jordi; Fernandez, Joaquin

    2010-01-01

    To increase communication and collaboration opportunities, members of a community must be aware of the social networks that exist within that community. This paper describes a social network monitoring system--the KIWI system--that enables users to register their interactions and visualize their social networks. The system was implemented in a…

  1. A Miniaturized Video System for Monitoring Drosophila Behavior

    Science.gov (United States)

    Bhattacharya, Sharmila; Inan, Omer; Kovacs, Gregory; Etemadi, Mozziyar; Sanchez, Max; Marcu, Oana

    2011-01-01

    Long-term spaceflight may induce a variety of harmful effects in astronauts, resulting in altered motor and cognitive behavior. The stresses experienced by humans in space - most significantly weightlessness (microgravity) and cosmic radiation - are difficult to accurately simulate on Earth. In fact, prolonged and concomitant exposure to microgravity and cosmic radiation can only be studied in space. Behavioral studies in space have focused on model organisms, including Drosophila melanogaster. Drosophila is often used due to its short life span and generational cycle, small size, and ease of maintenance. Additionally, the well-characterized genetics of Drosophila behavior on Earth can be applied to the analysis of results from spaceflights, provided that the behavior in space is accurately recorded. In 2001, the BioExplorer project introduced a low-cost option for researchers: the small satellite. While this approach enabled multiple inexpensive launches of biological experiments, it also imposed stringent restrictions on the monitoring systems in terms of size, mass, data bandwidth, and power consumption. Suggested parameters for size are on the order of 100 mm3 and 1 kg mass for the entire payload. For Drosophila behavioral studies, these engineering requirements are not met by commercially available systems. One system that does meet many requirements for behavioral studies in space is the actimeter. Actimeters use infrared light gates to track the number of times a fly crosses a boundary within a small container (3x3x40 mm). Unfortunately, the apparatus needed to monitor several flies at once would be larger than the capacity of the small satellite. A system is presented, which expands on the actimeter approach to achieve a highly compact, low-power, ultra-low bandwidth solution for simultaneous monitoring of the behavior of multiple flies in space. This also provides a simple, inexpensive alternative to the current systems for monitoring Drosophila

  2. Use of satellite images for the monitoring of water systems

    Science.gov (United States)

    Hillebrand, Gudrun; Winterscheid, Axel; Baschek, Björn; Wolf, Thomas

    2015-04-01

    Federal State of Baden-Wuerttemberg; BOWIS - information system for the Lake Constance) the maps will be made accessible to the public. The aim of the project is to implement a service that automatically recognizes new satellite images covering the area of selected water systems (lake, river or estuary) and therefore is able to continually update the data base. Furthermore, the service includes a procedure to analyse newly available data with the highest possible degree of automatization. It is planned to add new maps of SPM and Chl-a distributions to the data base within a couple of days after the satellite image was taken. A high degree of automatization is the essential condition to process a large number of satellite images each year at reasonable costs. It could be demonstrated by the Freshmon Project that there are simplified but robust algorithms and procedures existing. For the successful implementation of the service, it is important to further validate the results obtained by the service line as well as the used procedure and algorithms. Therefore, several test cases will be set up. Each case is going to include an analysis of the uncertainties to describe the expected deviation between values derived from earth observation data and the in-situ data obtained from the BfG and LUBW monitoring networks. Furthermore, it will include a description of possible sources of error and the boundary conditions which are most sensitive to the analysis. Test cases are planned to be made public with all necessary data. The scientific community is invited to use the data as a benchmark test case to develop their own algorithms and procedures.

  3. Monitoring Distributed Systems: A Relational Approach.

    Science.gov (United States)

    1982-12-01

    Feldman&Rovner 69]. Recently, several graphics systems employing a relational data base have been implemented [ Becerril et al. 79, Williams 74, Herot 80...Intelligent Gateway: System Overview. IEEE Transactions on Software Engineering SE-2(4), December, 1976. [ Becerril et al. 79] J. Becerril , R

  4. The Intelligent Door Monitoring System on Internet

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The hardware structure and software function of intelligence doormonitoring control systems on Internet is expounded. The remote managing function, database function, and the realization of dialing users are introduced. The reset card is installed to improve reliability. The design of the system is reasonable and reliable. Results showed that 10 percent of the line investment have been cut off.

  5. OVERSEER: An Expert System Monitor for the Psychiatric Hospital

    Science.gov (United States)

    Bronzino, Joseph D.; Morelli, Ralph A.; Goethe, John W.

    1988-01-01

    In order to improve patient care, comply with regulatory guidelines and decrease potential liability, psychiatric hospitals and clinics have been searching for computer systems to monitor the management and treatment of patients. This paper describes OVERSEER: a knowledge based system that monitors the treatment of psychiatric patients in real time. Based on procedures and protocols developed in the psychiatric setting, OVERSEER monitors the clinical database and issues alerts when standard clinical practices are not followed or when laboratory results or other clinical indicators are abnormal. Written in PROLOG, OVERSEER is designed to interface directly with the hospital's database, and, thereby utilizes all available pharmacy and laboratory data. Moreover, unlike the interactive expert systems developed for the psychiatric clinic, OVERSEER does not require extensive data entry by the clinician. Consequently, the chief benefit of OVERSEER's monitoring approach is the unobtrusive manner in which it evaluates treatment and patient responses and provides information regarding patient management.

  6. Design and Implementation of Food Monitoring System Based on WSN

    Directory of Open Access Journals (Sweden)

    Kong Xiangsheng

    2014-11-01

    Full Text Available This study describes a design and implementation of the Internet of things technology, aiming to design and realize an intelligent food monitoring system based on a wireless communication technology. A remote wireless monitoring system is proposed for food supply network based on Zigbee and RFID which are mainly used to detect and gather food supply information and upload information to monitoring center and download orders to coordinators. In this study, we propose a low-complexity, low-cost, low-data-rate and low-power-consumption design principles and food data clustering approach for WSN. Further, we propose several key issues that affect the practical deployment of gathering techniques in intelligent food monitoring system.

  7. Economic/Environmental power dispatch for power systems including wind farms

    Directory of Open Access Journals (Sweden)

    Imen BEN JAOUED

    2015-05-01

    Full Text Available This paper presents the problem of the Economic/Environmental power Dispatching (EED of hybrid power system including wind energies. The power flow model for a stall regulated fixed speed wind generator (SR-FSWG system is discussed to assess the steady-state condition of power systems with wind farms. Modified Newton-Raphson algorithm including SR-FSWG is used to solve the load flow equations in which the state variables of the wind generators are combined with the nodal voltage magnitudes and angles of the entire network. The EED problem is a nonlinear constrained multi-objective optimization problem, two competing fuel cost and pollutant emission objectives should be minimized simultaneously while satisfying certain system constraints. In this paper, the resolution is done by the algorithm multi-objective particle swarm optimization (MOPSO. The effectiveness of the proposed method has been verified on IEEE 6-generator 30-bus test system and using MATLAB software package.

  8. Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Ultrasonic Welding

    Science.gov (United States)

    Hofmann, Douglas C. (Inventor); Roberts, Scott N. (Inventor)

    2017-01-01

    Systems and methods in accordance with embodiments of the invention fabricate objects including metallic glass-based materials using ultrasonic welding. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: ultrasonically welding at least one ribbon to a surface; where at least one ribbon that is ultrasonically welded to a surface has a thickness of less than approximately 150.mu.m; and where at least one ribbon that is ultrasonically welded to a surface includes a metallic glass-based material.

  9. Monitoring and information management system at the Underground Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, G.S.; Chernis, P.J.; Bushman, A.T.; Spinney, M.H.; Backer, R.J. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada)

    1996-07-01

    Atomic Energy of Canada Limited (AECL) has developed a customer oriented monitoring and information management system at the Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba. The system is used to monitor instruments and manage, process, and distribute data. It consists of signal conditioners and remote loggers, central schedule and control systems, computer aided design and drafting work centres, and the communications linking them. The monitoring and communications elements are designed to meet the harsh demands of underground conditions while providing accurate monitoring of sensitive instruments to rigorous quality assured specifications. These instruments are used for testing of the concept for the deep geological disposal of nuclear fuel waste as part of the Canadian Nuclear Fuel Waste Management Program. Many of the tests are done in situ and at full-scale. The monitoring and information management system services engineering, research, and support staff working to design, develop, and demonstrate and present the concept. Experience gained during development of the monitoring and information management system at the URL, can be directly applied at the final disposal site. (author)

  10. Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Ashraf A. Tahat

    2009-01-01

    Full Text Available A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  11. Mobile messaging services-based personal electrocardiogram monitoring system.

    Science.gov (United States)

    Tahat, Ashraf A

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  12. Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System

    Science.gov (United States)

    Tahat, Ashraf A.

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services. PMID:19707531

  13. A transient energy function for power systems including the induction motor model

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A construction method for power system transient energy function is studied in the paper, which is simple and universal, and can unify the forms of some current energy functions. A transient energy function including the induction motor model is derived using the method. The unintegrable term is dealt with to get an approximate energy function. Simulations in a 3-bus system and in the WSCC 4-generator system verify the validity of the proposed energy function. The function can be applied to direct transient stability analysis of multi-machine large power systems and provides a tool for analysis of the interaction between the generator angle stability and the load voltage stability.

  14. Integrated system for remotely monitoring critical physiological parameters

    Science.gov (United States)

    Alexakis, S.; Karalis, S.; Asvestas, P.

    2015-09-01

    Monitoring several human parameters (temperature, heart rate, blood pressure etc.) is an essential task in health care in hospitals as well as in home care. This paper presents the design and implementation of an integrated, embedded system that includes an electrocardiograph of nine leads and two channels, a digital thermometer for measuring the body temperature and a power supply. The system provides networking capabilities (wired or wireless) and is accessible by means of a web interface that allows the user to select the leads, as well as to review the values of heart rate (beats per minute) and body temperature. Furthermore, there is the option of saving all the data in a Micro SD memory card or in a Google Spreadsheet. The necessary analog circuits for signal conditioning (amplification and filtering) were manufactured on printed circuit boards (PCB). The system was built around Arduino Yun, which is a platform that contains a microcontroller and a microprocessor running a special LINUX distribution. Furthermore, the Arduino Yun provides the necessary network connectivity capabilities by means of the integrated Wi-Fi and Ethernet interfaces. The web interface was developed using HTML pages with JavaScript support. The system was tested on simulated data as well as real data, providing satisfactory accuracy regarding the measurement of the heart rate (±3 bpm error) and the temperature (±0.3°C error).

  15. Monitoring the degree of implementation of an integrated delivery system

    Directory of Open Access Journals (Sweden)

    Réjean Hébert

    2004-09-01

    Full Text Available Introduction: The aim of the study was to develop a method to measure the implementation of specific components of an Integrated Service Delivery system for the frail elderly. The system includes six mechanisms and tools: (1 coordination of all organizations involved in delivering health and social services, (2 a single entry point, (3 case management, (4 a single assessment tool with a case-mix classification system, (5 an individualized service plan, and (6 a computerized clinical chart. Method: Focus groups of researchers, clinicians, managers and policy-makers identified quantitative indicators for each component. The six components were weighted according to their relative importance in order to generate a total score. Data were collected every six months over 30 months to establish the implementation degree in the three experimental areas: Sherbrooke, Granit and Coaticook in the Province of Quebec, Canada. Results: After 30 months, coordination is the most developed component in the three experimental areas. Overall, in July 2003, the Integrated Service Delivery system was implemented at the rate of 73%, 71% and 70% in Sherbrooke, Granit and Coaticook, respectively. Discussion: This type of quantitative assessment provides data for managers and researchers to monitor the implementation. Moreover, when there is an outcome study, the results of the outcome study can be correlated with the degree of implementation, thus allowing for dose-response analyzes and helping to decrease the “black box” effect.

  16. Travel Monitoring Analysis System (TMAS) (National)

    Data.gov (United States)

    Department of Transportation — The data included in the GIS Traffic Stations Version database have been collected by the FHWA from the State DOTs (NTAD 2015). Location referencing information was...

  17. Wide-area monitoring of interconnected power systems

    CERN Document Server

    Messina, Arturo Román

    2015-01-01

    This book provides a compact yet comprehensive treatment of advanced data-driven signal processing techniques for the analysis and characterization of both ambient power system data and transient oscillations resulting from major disturbances. Inspired by recent developments in multi-sensor data fusion, multi-temporal data assimilation techniques for power system monitoring are proposed and tested in the context of modern wide-area monitoring system architectures. Recent advances in understanding and modeling nonlinear, time-varying power system processes are reviewed and factors affecting the

  18. Remote monitoring: An implementation on the Gemini System

    Energy Technology Data Exchange (ETDEWEB)

    Sheridan, R.; Ondrik, M.; Kadner, S.; Resnik, W. [Aquila Technologies Group, Inc., Albuquerque, NM (United States); Chitumbo, K. [International Atomic Energy Agency, Vienna (Austria); Corbell, B. [Sandia National Labs., Albuquerque, NM (United States)

    1996-12-31

    The Gemini System consists of a sophisticated, digital surveillance unit and a high performance review system. Due to the open architectural design of the Gemini System, it provides an excellent hardware and software platform to support remote monitoring. The present Gemini System provides the user with the following Remote Monitoring features, via a modem interface and powerful support software: state-of-health reporting, alarm reporting, and remote user interface. Future enhancements will contribute significantly to the Gemini`s ability to provide a broader spectrum of network interfaces and remote review.

  19. Past Quantum States of a Monitored System

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Julsgaard, Brian; Mølmer, Klaus

    2013-01-01

    A density matrix ρ(t) yields probabilistic information about the outcome of measurements on a quantum system. We introduce here the past quantum state, which, at time T, accounts for the state of a quantum system at earlier times tstate Ξ(t) is composed of two objects, ρ......(t) and E(t), conditioned on the dynamics and the probing of the system until t and in the time interval [t, T], respectively. The past quantum state is characterized by its ability to make better predictions for the unknown outcome of any measurement at t than the conventional quantum state at that time....... On the one hand, our formalism shows how smoothing procedures for estimation of past classical signals by a quantum probe [M. Tsang, Phys. Rev. Lett. 102 250403 (2009)] apply also to describe the past state of the quantum system itself. On the other hand, it generalizes theories of pre- and postselected...

  20. Thermal Insulation System for Non-Vacuum Applications Including a Multilayer Composite

    Science.gov (United States)

    Fesmire, James E. (Inventor)

    2017-01-01

    The thermal insulation system of the present invention is for non-vacuum applications and is specifically tailored to the ambient pressure environment with any level of humidity or moisture. The thermal insulation system includes a multilayered composite including i) at least one thermal insulation layer and at least one compressible barrier layer provided as alternating, successive layers, and ii) at least one reflective film provided on at least one surface of the thermal insulation layer and/or said compressible barrier layer. The different layers and materials and their combinations are designed to provide low effective thermal conductivity for the system by managing all modes of heat transfer. The thermal insulation system includes an optional outer casing surrounding the multilayered composite. The thermal insulation system is particularly suited for use in any sub-ambient temperature environment where moisture or its adverse effects are a concern. The thermal insulation system provides physical resilience against damaging mechanical effects including compression, flexure, impact, vibration, and thermal expansion/contraction.

  1. Toward a Continuous Intravascular Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Pedro Irazoqui

    2010-12-01

    Full Text Available Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. The impedance across the hydrogel depended solely on the thickness and had an average increase of 47 W/mm. The hydrogels exposed to a hyperglycemic solution were more porous than the hydrogels exposed to a normal glycemic solution. The diffusivity of 390 Da MW fluorescein isothiocyanate in hydrogels exposed to normal and hyperglycemic solutions was examined using fluorescence recovery after photobleaching and was found to be 9.3 × 10−14 and 41.4 × 10−14 m2/s, respectively, compared to 6.2 × 10−10 m2/s in glucose solution. There was no significant difference between the permeability of hydrogels in normal and hyperglycemic glucose solutions with averages being 5.26 × 10−17 m2 and 5.80 × 10−17 m2, respectively, which resembles 2–4% agarose gels. A prototype design is presented for continuous intravascular glucose monitoring by attaching a glucose sensor to an FDA-approved stent.

  2. Hydrogen and Oxygen Gas Monitoring System Design and Operation

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader; Kevin G. DeWall; J. Stephen Herring

    2007-06-01

    This paper describes pertinent design practices of selecting types of monitors, monitor unit placement, setpoint selection, and maintenance considerations for gas monitors. While hydrogen gas monitors and enriched oxygen atmosphere monitors as they would be needed for hydrogen production experiments are the primary focus of this paper, monitors for carbon monoxide and carbon dioxide are also discussed. The experiences of designing, installing, and calibrating gas monitors for a laboratory where experiments in support of the DOE Nuclear Hydrogen Initiative (NHI) are described along with codes, standards, and regulations for these monitors. Information from the literature about best operating practices is also presented. The NHI program has two types of activities. The first, near-term activity is laboratory and pilot-plant experimentation with different processes in the kilogram per day scale to select the most promising types of processes for future applications of hydrogen production. Prudent design calls for indoor gas monitors to sense any hydrogen leaks within these laboratory rooms. The second, longer-term activity is the prototype, or large-scale plants to produce tons of hydrogen per day. These large, outdoor production plants will require area (or “fencepost”) monitoring of hydrogen gas leaks. Some processes will have oxygen production with hydrogen production, and any oxygen releases are also safety concerns since oxygen gas is the strongest oxidizer. Monitoring of these gases is important for personnel safety of both indoor and outdoor experiments. There is some guidance available about proper placement of monitors. The fixed point, stationary monitor can only function if the intruding gas contacts the monitor. Therefore, monitor placement is vital to proper monitoring of the room or area. Factors in sensor location selection include: indoor or outdoor site, the location and nature of potential vapor/gas sources, chemical and physical data of the

  3. BWR online monitoring system based on noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz-Villafuerte, Javier [Departamento de Sistemas Nucleares, Instituto Nacional de Investigaciones Nucleares, Carr. Mexico-Toluca S/N, Ocoyoacac, Edo. de Mexico, 52750 (Mexico)]. E-mail: jov@nuclear.inin.mx; Castillo-Duran, Rogelio [Departamento de Sistemas Nucleares, Instituto Nacional de Investigaciones Nucleares, Carr. Mexico-Toluca S/N, Ocoyoacac, Edo. de Mexico, 52750 (Mexico)]. E-mail: rcd@nuclear.inin.mx; Alonso, Gustavo [Departamento de Sistemas Nucleares, Instituto Nacional de Investigaciones Nucleares, Carr. Mexico-Toluca S/N, Ocoyoacac, Edo. de Mexico, 52750 (Mexico)]. E-mail: galonso@nuclear.inin.mx; Calleros-Micheland, Gabriel [Central Nuclear de Laguna Verde, Comision Federal de Electricidad, Carr. Cardel-Nautla, km. 42.5, Alto Lucero, Veracruz (Mexico)]. E-mail: gcm9acpp@cfe.gob.mx

    2006-11-15

    A monitoring system for during operation early detection of an anomaly and/or faulty behavior of equipment and systems related to the dynamics of a boiling water reactor (BWR) has been developed. The monitoring system is based on the analysis of the 'noise' or fluctuations of a signal from a sensor or measurement device. An efficient prime factor algorithm to compute the fast Fourier transform allows the continuous, real-time comparison of the normalized power spectrum density function of the signal against previously stored reference patterns in a continuously evolving matrix. The monitoring system has been successfully tested offline. Four examples of the application of the monitoring system to the detection and diagnostic of faulty equipment behavior are presented in this work: the detection of two different events of partial blockage at the jet pump inlet nozzle, miss-calibration of a recirculation mass flow sensor, and detection of a faulty data acquisition card. The events occurred at the two BWR Units of the Laguna Verde Nuclear Power Plant. The monitoring system and its possible coupling to the data and processing information system of the Laguna Verde Nuclear Power Plant are described. The signal processing methodology is presented along with the introduction of the application of the evolutionary matrix concept for determining the base signature of reactor equipment or component and the detection of off normal operation conditions.

  4. Health Monitoring System Technology Assessments: Cost Benefits Analysis

    Science.gov (United States)

    Kent, Renee M.; Murphy, Dennis A.

    2000-01-01

    The subject of sensor-based structural health monitoring is very diverse and encompasses a wide range of activities including initiatives and innovations involving the development of advanced sensor, signal processing, data analysis, and actuation and control technologies. In addition, it embraces the consideration of the availability of low-cost, high-quality contributing technologies, computational utilities, and hardware and software resources that enable the operational realization of robust health monitoring technologies. This report presents a detailed analysis of the cost benefit and other logistics and operational considerations associated with the implementation and utilization of sensor-based technologies for use in aerospace structure health monitoring. The scope of this volume is to assess the economic impact, from an end-user perspective, implementation health monitoring technologies on three structures. It specifically focuses on evaluating the impact on maintaining and supporting these structures with and without health monitoring capability.

  5. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.

    Science.gov (United States)

    Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk

    2016-03-11

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.

  6. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Sungjun Kwon

    2016-03-01

    Full Text Available In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR and heart rate variability (HRV, to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1 upgrading the sensor device; (2 improving the feature extraction process; and (3 evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use.

  7. Research and implementation of road monitoring GIS system

    Science.gov (United States)

    Yu, Jia; Wu, Jianping; Yi, Min

    2007-06-01

    Based on the analysis of the shortcomings of the traditional video monitoring system, the paper presents an efficient road monitoring system based on GIS technology, named Road Monitoring GIS (RMGIS) System. The basic framework of the system modules is set out. The key technology and implementation of the special function are highlighted put forward. The paper takes a new interpretation of the buffer zone, topological network, geocoding and explains the construct method of some mathematical model. Advanced functions such as road topological network, moving object database and adaptive image recognition are also explored and studied in a certain extent. Now the system has been successfully applied to the road management in Shanghai urban area, some intelligent function will be implemented in the follow-up project.

  8. Development of Core Monitoring System for Nuclear Power Plants (I)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.H.; Kim, Y.B.; Park, M.G; Lee, E.K.; Shin, H.C.; Lee, D.J. [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    1997-12-31

    1.Object and Necessity of the Study -The main objectives of this study are (1)conversion of APOLLO version BEACON system to HP-UX version core monitoring system, (2)provision of the technical bases to enhance the in-house capability of developing more advanced core monitoring system. 2.Results of the Study - In this study, the revolutionary core monitoring technologies such as; nodal analysis and isotope depletion calculation method, advanced schemes for power distribution control, and treatment of nuclear databank were established. The verification and validation work has been successfully performed by comparing the results with those of the design code and measurement data. The advanced graphic user interface and plant interface method have been implemented to ensure the future upgrade capability. The Unix shell scripts and system dependent software are also improved to support administrative functions of the system. (author). 14 refs., 112 figs., 52 tabs.

  9. Scientific Comparison of Different Online Heart Rate Monitoring Systems

    Directory of Open Access Journals (Sweden)

    Martin Schönfelder

    2011-01-01

    Full Text Available Recent technical development focused on real-time heart rate monitoring instead of postexercise evaluation of recorded data. There are several systems on the market that allow direct and real-time monitoring of several individuals at the same time. The present study compared the systems of Polar, Acentas, Activio, and Suunto in a field test with twelve subjects regarding failure quota, operating distance, and ECG validity. Moreover, the installation and use of software and hardware were evaluated with a quality rating system. Chest belts were evaluated with a questionnaire, too. Overall the system of Acentas reached the best mark of all systems, but detailed results showed that every system has its advantages and disadvantages depending on using purpose, location, and weather. So this evaluation cannot recommend a single system but rather shows strength and weakness of all systems and additionally can be used for further system improvements.

  10. DISTRIBUTED MONITORING SYSTEM RELIABILITY ESTIMATION WITH CONSIDERATION OF STATISTICAL UNCERTAINTY

    Institute of Scientific and Technical Information of China (English)

    Yi Pengxing; Yang Shuzi; Du Runsheng; Wu Bo; Liu Shiyuan

    2005-01-01

    Taking into account the whole system structure and the component reliability estimation uncertainty, a system reliability estimation method based on probability and statistical theory for distributed monitoring systems is presented. The variance and confidence intervals of the system reliability estimation are obtained by expressing system reliability as a linear sum of products of higher order moments of component reliability estimates when the number of component or system survivals obeys binomial distribution. The eigenfunction of binomial distribution is used to determine the moments of component reliability estimates, and a symbolic matrix which can facilitate the search of explicit system reliability estimates is proposed. Furthermore, a case of application is used to illustrate the procedure, and with the help of this example, various issues such as the applicability of this estimation model, and measures to improve system reliability of monitoring systems are discussed.

  11. Middle infrared optoelectronic absorption systems for monitoring physiological glucose solutions

    Science.gov (United States)

    Martin, W. Blake

    Tight monitoring of the glucose levels for diabetic individuals is essential to control long-term complications. A definitive diabetes management system has yet to be developed for the diabetic. This research investigates the application of middle infrared absorption frequencies for monitoring glucose levels in biological solutions. Three frequencies were identified using a Fourier transform infrared spectrometer and correlated to changes in glucose concentrations. The 1035 +/- 1 cm-1 frequency was determined to be the best representative frequency. Other biological molecules contributed no significant interference to monitoring glucose absorption. A second frequency at 1193 cm-1 was suggested as a representative background absorption frequency, which could be used for more accurate glucose absorption values. Next, a quantum cascade laser optoelectronic absorption system was designed and developed to monitor glucose. After careful alignment and design, the system was used to monitor physiological glucose concentrations. Correlation at 1036 cm-1 with glucose changes was comparable to the previous results. The use of the background absorption frequency was verified. This frequency essentially acts as a calibrating frequency to adjust in real-time to any changes in the background absorption that may alter the accuracy of the predicted glucose value. An evanescent wave cavity ring-down spectroscopy technique was explored to monitor molecules in a biological solution. Visible light at 425 nm was used to monitor hemoglobin in control urine samples. An adsorption isotherm for hemoglobin was detectable to limit of 5.8 nM. Evanescent wave cavity ring-down spectroscopy would be useful for a glucose solution. Given an equivalent system designed for the middle infrared, the molar extinction coefficient of glucose allows for a detectable limit of 45 mg/dl for a free-floating glucose solution, which is below normal physiological concentrations. The future use of a hydrophobic

  12. Biomedical performance monitoring and assessment of astronauts by means of an ocular vestibular monitoring system

    Science.gov (United States)

    Souvestre, Philippe A.; Landrock, Clinton

    2007-02-01

    The paper focuses on the strong correlation between unmitigated symptoms exhibited by post Space flight astronauts, and symptoms associated with postural deficiency syndrome (PDS) that can be correctly assessed, identified, and monitored via a neurophysiological ocular-vestibular monitoring system (OVMS). From examining clinical data taken over a 10-year period from patients experiencing PDS related acute and chronic post-traumatic medical conditions, the authors show the potential for current assessment and monitoring techniques to examine better the impacts on astronaut neurophysiology. The data presented provide strong evidence that this biomedical monitoring and assessment methodology along with appropriate technology can lead to a better understanding of astronaut post-flight neurophysiology, which is necessary if human exploration in Space is to continue on a successful path.

  13. 76 FR 4120 - The National Antimicrobial Resistance Monitoring System Strategic Plan 2011-2015; Request for...

    Science.gov (United States)

    2011-01-24

    ... HUMAN SERVICES Food and Drug Administration The National Antimicrobial Resistance Monitoring System... public comment of a document for The National Antimicrobial Resistance Monitoring System (NARMS) entitled... systems monitoring antimicrobial resistance in other countries. Foodborne diseases are an important cause...

  14. Monitoring aquatic environments with autonomous systems

    DEFF Research Database (Denmark)

    Christensen, Jesper Philip Aagaard

    High frequency measurements from autonomous sensors have become a widely used tool among aquatic scientists. This report focus primarily on the use of ecosystem metabolism based on high frequency oxygen measurements and relates the calculations to spatial variation, biomass of the primary producers...... and in shallow systems the macrophytes can completely dominate primary production. This was despite the fact that the plants in the studied system were light-saturated most of the light hours and occasionally carbon limited. It was also shown that the GPP and the total phytoplankton biomass in a nutrient...

  15. Stochastic self-monitoring of autonomous systems

    OpenAIRE

    2012-01-01

    A probabilistic method is presented for high level task planning of autonomous, mobile systems under partial observability of states and partial knowledge of transition laws. Partial state observability is addressed by directed Markov fields which support the detection of relationships between pairs of observed variables in competition to other such pairs.

  16. HUMS - Health And Usage Monitoring System

    Directory of Open Access Journals (Sweden)

    Boris Popović

    2012-10-01

    Full Text Available The article presents a principle layout of a modem HUMSalong with the basic system operating procedures. The articlealso deals with the impact of HUMS Oil aircraft maintenanceprocedures and economy, the impact on maintenance systemarchitecture and the implementation of cost-saving measures.The improvement of flight-safety as a consequence of HUMSapplication is also discussed.

  17. G-Cloud Monitor: A Cloud Monitoring System for Factory Automation for Sustainable Green Computing

    Directory of Open Access Journals (Sweden)

    Hwa-Young Jeong

    2014-11-01

    Full Text Available Green and cloud computing (G-cloud are new trends in all areas of computing. The G-cloud provides an efficient function, which enables users to access their programs, systems and platforms at anytime and anyplace. Green computing can also yield greener technology by reducing power consumption for sustainable environments. Furthermore, in order to apply user needs to the system development, the user characteristics are regarded as some of the most important factors to be considered in product industries. In this paper, we propose a cloud monitoring system to observe and manage the manufacturing system/factory automation for sustainable green computing. For monitoring systems, we utilized the resources in the G-cloud environments, and hence, it can reduce the amount of system resources and devices, such as system power and processes. In addition, we propose adding a user profile to the monitoring system in order to provide a user-friendly function. That is, this function allows system configurations to be automatically matched to the individual’s requirements, thus increasing efficiency.

  18. Development of Dual-light Path Monitoring System of Optical Thin-film Thickness

    Institute of Scientific and Technical Information of China (English)

    XU Shi-jun

    2005-01-01

    The accurate monitoring of optical thin-film thickness is a key technique for depositing optical thin-film. For existing coating equipments, which are low precision and automation level on monitoring thin-film thickness, a new photoelectric control and analysis system has been developed. In the new system, main techniques include a photoelectric system with dual-light path, a dual-lock-phase circuit system and a comprehensive digital processing-control-analysis system.The test results of new system show that the static and dynamic stabilities and the control precision of thin-film thickness are extremely increased. The standard deviation of thin-film thickness, which indicates the duplication of thin-film thickness monitoring, is equal to or less than 0.72%. The display resolution limit on reflectivity is 0.02 %. In the system, the linearity of drift is very high, and the static drift ratio approaches zero.

  19. Systems Health Monitoring — From Ground to Air — The Aerospace Challenges

    Science.gov (United States)

    Austin, Mary

    2007-03-01

    The aerospace industry and the government are significantly investing in jet engine systems health monitoring. Government organizations such as the Air Force, Navy, Army, National Labs and NASA are investing in the development of state aware sensing for health monitoring of jet engines such as the Joint Strike Fighter, F119 and F100's. This paper will discuss on-going work in systems health monitoring for jet engines. Topics will include a general discussion of the approaches to engine structural health monitoring and the prognosis of engine component life. Real-world implementation challenges on the ground and in the air will be reviewed. The talk will conclude with a prediction of where engine health monitoring will be in twenty years.

  20. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.