WorldWideScience

Sample records for monitoring protocol deviations

  1. Phase-I monitoring of standard deviations in multistage linear profiles

    Science.gov (United States)

    Kalaei, Mahdiyeh; Soleimani, Paria; Niaki, Seyed Taghi Akhavan; Atashgar, Karim

    2018-03-01

    In most modern manufacturing systems, products are often the output of some multistage processes. In these processes, the stages are dependent on each other, where the output quality of each stage depends also on the output quality of the previous stages. This property is called the cascade property. Although there are many studies in multistage process monitoring, there are fewer works on profile monitoring in multistage processes, especially on the variability monitoring of a multistage profile in Phase-I for which no research is found in the literature. In this paper, a new methodology is proposed to monitor the standard deviation involved in a simple linear profile designed in Phase I to monitor multistage processes with the cascade property. To this aim, an autoregressive correlation model between the stages is considered first. Then, the effect of the cascade property on the performances of three types of T 2 control charts in Phase I with shifts in standard deviation is investigated. As we show that this effect is significant, a U statistic is next used to remove the cascade effect, based on which the investigated control charts are modified. Simulation studies reveal good performances of the modified control charts.

  2. Investigation of the Study Characteristics Affecting Clinical Trial Quality Using the Protocol Deviations Leading to Exclusion of Subjects From the Per Protocol Set Data in Studies for New Drug Application: A Retrospective Analysis.

    Science.gov (United States)

    Kohara, Norihito; Kaneko, Masayuki; Narukawa, Mamoru

    2018-01-01

    The concept of the risk-based approach has been introduced as an effort to secure the quality of clinical trials. In the risk-based approach, identification and evaluation of risk in advance are considered important. For recently completed clinical trials, we investigated the relationship between study characteristics and protocol deviations leading to the exclusion of subjects from Per Protocol Set (PPS) efficacy analysis. New drugs approved in Japan in the fiscal year 2014-2015 were targeted in the research. The reasons for excluding subjects from the PPS efficacy analysis were described in 102 trials out of 492 in the summary of new drug application documents, which was publicly disclosed after the drug's regulatory approval. The author extracted these reasons along with the numbers of the cases and the study characteristics of each clinical trial. Then, the direct comparison, univariate regression analysis, and multivariate regression analysis was carried out based on the exclusion rate. The study characteristics for which exclusion of subjects from the PPS efficacy analysis were frequently observed was multiregional clinical trials in study region; inhalant and external use in administration route; Anti-infective for systemic use; Respiratory system, Dermatologicals, and Nervous system in therapeutic drug under the Anatomical Therapeutic Chemical Classification. In the multivariate regression analysis, the clinical trial variables of inhalant, Respiratory system, or Dermatologicals were selected as study characteristics leading to a higher exclusion rate. The characteristics of the clinical trial that is likely to cause protocol deviations that will affect efficacy analysis were suggested. These studies should be considered for specific attention and priority observation in the trial protocol or its monitoring plan and execution, such as a clear description of inclusion/exclusion criteria in the protocol, development of training materials to site staff, and

  3. Attacks exploiting deviation of mean photon number in quantum key distribution and coin tossing

    Science.gov (United States)

    Sajeed, Shihan; Radchenko, Igor; Kaiser, Sarah; Bourgoin, Jean-Philippe; Pappa, Anna; Monat, Laurent; Legré, Matthieu; Makarov, Vadim

    2015-03-01

    The security of quantum communication using a weak coherent source requires an accurate knowledge of the source's mean photon number. Finite calibration precision or an active manipulation by an attacker may cause the actual emitted photon number to deviate from the known value. We model effects of this deviation on the security of three quantum communication protocols: the Bennett-Brassard 1984 (BB84) quantum key distribution (QKD) protocol without decoy states, Scarani-Acín-Ribordy-Gisin 2004 (SARG04) QKD protocol, and a coin-tossing protocol. For QKD we model both a strong attack using technology possible in principle and a realistic attack bounded by today's technology. To maintain the mean photon number in two-way systems, such as plug-and-play and relativistic quantum cryptography schemes, bright pulse energy incoming from the communication channel must be monitored. Implementation of a monitoring detector has largely been ignored so far, except for ID Quantique's commercial QKD system Clavis2. We scrutinize this implementation for security problems and show that designing a hack-proof pulse-energy-measuring detector is far from trivial. Indeed, the first implementation has three serious flaws confirmed experimentally, each of which may be exploited in a cleverly constructed Trojan-horse attack. We discuss requirements for a loophole-free implementation of the monitoring detector.

  4. National protocol framework for the inventory and monitoring of bees

    Science.gov (United States)

    Droege, Sam; Engler, Joseph D.; Sellers, Elizabeth A.; Lee O'Brien,

    2016-01-01

    This national protocol framework is a standardized tool for the inventory and monitoring of the approximately 4,200 species of native and non-native bee species that may be found within the National Wildlife Refuge System (NWRS) administered by the U.S. Fish and Wildlife Service (USFWS). However, this protocol framework may also be used by other organizations and individuals to monitor bees in any given habitat or location. Our goal is to provide USFWS stations within the NWRS (NWRS stations are land units managed by the USFWS such as national wildlife refuges, national fish hatcheries, wetland management districts, conservation areas, leased lands, etc.) with techniques for developing an initial baseline inventory of what bee species are present on their lands and to provide an inexpensive, simple technique for monitoring bees continuously and for monitoring and evaluating long-term population trends and management impacts. The latter long-term monitoring technique requires a minimal time burden for the individual station, yet can provide a good statistical sample of changing populations that can be investigated at the station, regional, and national levels within the USFWS’ jurisdiction, and compared to other sites within the United States and Canada. This protocol framework was developed in cooperation with the United States Geological Survey (USGS), the USFWS, and a worldwide network of bee researchers who have investigated the techniques and methods for capturing bees and tracking population changes. The protocol framework evolved from field and lab-based investigations at the USGS Bee Inventory and Monitoring Laboratory at the Patuxent Wildlife Research Center in Beltsville, Maryland starting in 2002 and was refined by a large number of USFWS, academic, and state groups. It includes a Protocol Introduction and a set of 8 Standard Operating Procedures or SOPs and adheres to national standards of protocol content and organization. The Protocol Narrative

  5. Updating the U.S. SMART dispersant efficacy monitoring protocol

    International Nuclear Information System (INIS)

    Trudel, K.; Belore, R.; VanHaverbeke, M.; Mullin, J.

    2009-01-01

    The Special Monitoring of Applied Response Technologies (SMART) is a written dispersant effectiveness monitoring protocol developed in the United States in the mid 1990s. It has been the subject of considerable review and research since its development. This paper reported on the 2007-2008 review of the SMART dispersant effectiveness monitoring protocol which involved the following 3 tasks: (1) stakeholders reviewed their experience with SMART and identified the key deficiencies in the current protocol, (2) the SMART monitoring experience gathered during dispersant effectiveness testing at the Ohmsett National Oil Spill Response Test Facility was reviewed to evaluate the usefulness of existing SMART decision criteria, (3) available commercial off-the-shelf instruments (COTS) were surveyed to identify the instruments that might be more effective or simpler to use than those presently in use. The review concluded that the three-tiered approach in SMART was appropriate, but better guidance was needed for users. In addition, the fluorometer historically used for monitoring of dispersed oil was found to have several operating challenges and should be replaced with more modern equipment. It was recommended that all U.S. government sponsored monitoring teams work with identical instruments and operating protocols. The COTS survey identified 6 potentially suitable submersible and field-portable fluorometers and three particle-size analyzers. 26 refs., 5 tabs., 1 fig

  6. Protocol Monitoring Energy Conservation; Protocol Monitoring Energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Beleidsstudies, Petten (Netherlands); Mannaerts, H. [Centraal Planburea CPB, Den Haag (Netherlands); Tinbergen, W. [Centraal Bureau voor de Statistiek CBS, Den Haag (Netherlands); Vreuls, H.H.J. [Nederlandse onderneming voor energie en milieu Novem, Utrecht (Netherlands); Wesselink, B. [Rijksinstituut voor Volksgezondheid en Milieuhygiene RIVM, Bilthoven (Netherlands)

    2001-12-01

    On request of the Dutch ministry of Economic Affairs five institutes have collaborated to create a 'Protocol Monitoring Energy Conservation', a common method and database to calculate the amount of energy savings realised in past years. The institutes concerned are the Central Bureau of Statistics (CBS), the Netherlands Bureau for Economic Policy Analysis (CPB), the Energy research Centre of the Netherlands (ECN), the National Agency for Energy and Environment (Novem) and the Netherlands Institute of Public Health and the Environment (RIVM). The institutes have agreed upon a clear definition of energy use and energy savings. The demarcation with renewable energy, the saving effects of substitution between energy carriers and the role of import and export of energy have been elaborated. A decomposition method is used to split up the observed change in energy use in a number of effects, on a national and sectoral level. This method includes an analysis of growth effects, effects of structural changes in production and consumption activities and savings on end use or with more efficient conversion processes. To calculate these effects the total energy use is desegregated as much as possible. For each segment a reference energy use is calculated according to the trend in a variable which is supposed to be representative for the use without savings. The difference with the actual energy use is taken as the savings realised. Results are given for the sectors households, industry, agriculture, services and government, transportation and the energy sector; as well as a national figure. A special feature of the protocol method is the application of primary energy use figures in the determination of savings for end users. This means that the use of each energy carrier is increased with a certain amount, according to the conversion losses caused elsewhere in the energy system. The losses concern the base year energy sector and losses abroad for imports of secondary

  7. Protocols of radiocontaminant air monitoring for inhalation exposure estimates

    International Nuclear Information System (INIS)

    Shinn, J.H.

    1995-09-01

    Monitoring the plutonium and americium particle emissions from soils contaminated during atmospheric nuclear testing or due to accidental releases is important for several reasons. First, it is important to quantify the extent of potential human exposure from inhalation of alpha-emitting particles, which is the major exposure pathway from transuranic radionuclides. Second, the information provided by resuspension monitoring is the basis of criteria that determine the target soil concentrations for management and cleanup of contaminated soil sites. There are other radioactive aerosols, such as the fission products (cesium and strontium) and neutron-activation products (europium isotopes), which may be resuspended and therefore necessary to monitor as well. This Standard Protocol (SP) provides the method used for radiocontaminant air monitoring by the Health and Ecological Assessment Division (formerly Environmental Sciences Division), Lawrence Livermore National Laboratory, as developed and tested at Nevada Test Site (NTS) and in the Marshall Islands. The objective of this SP is to document the applications and methods of monitoring of all the relevant variables. This protocol deals only with measuring air concentrations of radionuclides and total suspended particulates (TSP, or open-quotes dustclose quotes). A separate protocol presents the more difficult measurements required to determine transuranic aerosol emission rates, or open-quotes resuspension rateclose quotes

  8. Field Monitoring Protocol. Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maguire, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  9. Field Monitoring Protocol: Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  10. A field protocol to monitor cavity-nesting birds

    Science.gov (United States)

    J. Dudley; V. Saab

    2003-01-01

    We developed a field protocol to monitor populations of cavity-nesting birds in burned and unburned coniferous forests of western North America. Standardized field methods are described for implementing long-term monitoring strategies and for conducting field research to evaluate the effects of habitat change on cavity-nesting birds. Key references (but not...

  11. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    International Nuclear Information System (INIS)

    2016-01-01

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  12. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  13. Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin

    2011-02-01

    Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.

  14. An Audit of Protocol Deviations Submitted to an Institutional Ethics Committee of a Tertiary Care Hospital.

    Directory of Open Access Journals (Sweden)

    Sharmila V Jalgaonkar

    Full Text Available Protocol deviations (PDs may jeopardize safety, rights, and welfare of subjects and data integrity. There is scarce literature and no guidelines for Institutional Ethics Committees (IECs to process PD reports. The PD reports submitted to IECs from Jan 2011 to August 2014 were analyzed retrospectively. Types of studies reporting PDs, category and type of PDs, PD rate per participant, time of reporting PD since its occurrence and corrective actions stated by principal investigator (PI for major deviations were noted. Out of 447 PDs from 73/1387 total studies received during study period, 402 were from 126 pharma studies. Investigator initiated studies and dissertations reported negligible PDs. Median number of PDs was 4 per protocol. Out of 447 PDs, 304 were related to study procedure, 87, 47 and 9 were from safety, informed consent document (ICD and eligibility category respectively. The most common reason for PDs was incomplete ICD (22/47. Maximum study procedure related PDs were due to patient visiting outside window period (126/304. Thirty five of 87 PDs were due to missed safety assessment. The overall PD reporting rate per participant was 0.08. In 90% of reports, date of occurrence of PD was not specified. The median delay for reporting PDs after occurrence was 94 days. PDs classified as Major were 73% (323/447. The most common corrective actions stated by PI were participant counseling (85/323 and caution in future (70/323. The study findings emphasize the need for GCP training at regular interval of study team members. IEC have to be vigilant and visit sites frequently, take initiative and formulate guidelines regarding PD reporting.

  15. Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Mervyn D. [Indiana University School of Medicine, Department of Radiology, Riley Children' s Hospital, Indianapolis, IN (United States); Riley Hospital for Children, Department of Radiology, Indianapolis, IN (United States); Cooper, Matt L.; Piersall, Kelly [Indiana University School of Medicine, Department of Radiology, Riley Children' s Hospital, Indianapolis, IN (United States); Apgar, Bruce K. [Agfa HealthCare Corporation, Greenville, SC (United States)

    2011-05-15

    Many methods are used to track patient exposure during acquisition of plain film radiographs. A uniform international standard would aid this process. To evaluate and describe a new, simple quality-assurance method for monitoring patient exposure. This method uses the ''exposure index'' and the ''deviation index,'' recently developed by the International Electrotechnical Commission (IEC) and American Association of Physicists in Medicine (AAPM). The deviation index measures variation from an ideal target exposure index value. Our objective was to determine whether the exposure index and the deviation index can be used to monitor and control exposure drift over time. Our Agfa workstation automatically keeps a record of the exposure index for every patient. The exposure index and deviation index were calculated on 1,884 consecutive neonatal chest images. Exposure of a neonatal chest phantom was performed as a control. Acquisition of the exposure index and calculation of the deviation index was easily achieved. The weekly mean exposure index of the phantom and the patients was stable and showed <10% change during the study, indicating no exposure drift during the study period. The exposure index is an excellent tool to monitor the consistency of patient exposures. It does not indicate the exposure value used, but is an index to track compliance with a pre-determined target exposure. (orig.)

  16. Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates

    International Nuclear Information System (INIS)

    Cohen, Mervyn D.; Cooper, Matt L.; Piersall, Kelly; Apgar, Bruce K.

    2011-01-01

    Many methods are used to track patient exposure during acquisition of plain film radiographs. A uniform international standard would aid this process. To evaluate and describe a new, simple quality-assurance method for monitoring patient exposure. This method uses the ''exposure index'' and the ''deviation index,'' recently developed by the International Electrotechnical Commission (IEC) and American Association of Physicists in Medicine (AAPM). The deviation index measures variation from an ideal target exposure index value. Our objective was to determine whether the exposure index and the deviation index can be used to monitor and control exposure drift over time. Our Agfa workstation automatically keeps a record of the exposure index for every patient. The exposure index and deviation index were calculated on 1,884 consecutive neonatal chest images. Exposure of a neonatal chest phantom was performed as a control. Acquisition of the exposure index and calculation of the deviation index was easily achieved. The weekly mean exposure index of the phantom and the patients was stable and showed <10% change during the study, indicating no exposure drift during the study period. The exposure index is an excellent tool to monitor the consistency of patient exposures. It does not indicate the exposure value used, but is an index to track compliance with a pre-determined target exposure. (orig.)

  17. Monitoring System with Two Central Facilities Protocol

    Directory of Open Access Journals (Sweden)

    Caesar Firdaus

    2017-03-01

    Full Text Available The security of data and information on government’s information system required proper way of defending against threat. Security aspect can be achieved by using cryptography algorithm, applying information hiding concept, and implementing security protocol. In this research, two central facilities protocol was implemented on Research and Development Center of Mineral and Coal Technology’s Cooperation Contract Monitoring System by utilizing AES and whitespace manipulation algorithm. Adjustment on the protocol by creating several rule of validation ID’s generation and checking processes could fulfill two of four cryptography objectives, consist of authentication and non-repudiation. The solid collaboration between central legitimization agency (CLA, central tabulating facility (CTF, and client is the main idea in two central facilities protocol. The utilization of AES algorithm could defend the data on transmission from man in the middle attack scenario. On the other hand, whitespace manipulation algorithm provided data integrity aspect of the document that is uploaded to the system itself. Both of the algorithm fulfill confidentiality, data integrity, and authentication.

  18. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the International Protocol

    Directory of Open Access Journals (Sweden)

    Li Li

    2008-10-01

    Full Text Available Li Li1, XinYu Zhang1, ChunHong Yan1, QingXiang Liang21Biomedical Engineering Lab, Faculty of Information Engineering, ShenZhen University, ShenZhen, China; 2Bao An People’s Hospital, ShenZhen, ChinaObjective: Extensive marketing of devices for self-measurement of blood pressure has created a need for purchasers to be able to satisfy themselves that such devices have been evaluated according to agreed criteria. The Oregon Scientific BPU 330 blood pressure monitor is an electronic device for upper arm measurement. This study assessed the accuracy of the Oregon Scientific BPU 330 blood pressure monitor according to the International Protocol by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension for validation of blood pressure measuring devices.Method: 52 participants over 30 years of age were studied in the validation. Nine blood pressure measurements were taken alternately with a mercury sphygmomanometer by two observers, and by the supervisor, using the BPU 330 device. A total of 33 participants were selected for the analysis. The validation was divided into two phases. Phase 1 included 15 participants. If the device passed phase 1, 18 more participants were included. The 99 pairs of measurements were compared according to the International Protocol. The device was given a pass/fail recommendation based on its accuracy compared with the mercury standard (within 5, 10, and 15 mmHg, as well as the number met in the ranges specified by the International Protocol.Results: The mean and standard deviation of the difference between the mean of the observers and the BPU 330 device were 1.7 ± 4.7 mmHg and 2.8 ± 3.9 mmHg for systolic blood pressure (SBP and diastolic blood pressure (DBP, respectively. In phase 1, the device passed with a total of 33, 43, and 44 SBP readings; 38, 44, and 45 DBP readings were within 5, 10, and 15 mmHg, respectively. In phase 2.1, 81, 95, and 96 for SBP, and 83, 95, and 98 for DBP

  19. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    International Nuclear Information System (INIS)

    MacDougall, R.

    2016-01-01

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  20. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    Energy Technology Data Exchange (ETDEWEB)

    MacDougall, R. [Boston Children’s Hospital (United States)

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  1. Improvement of burn pain management through routine pain monitoring and pain management protocol.

    Science.gov (United States)

    Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook

    2013-06-01

    Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  2. Applying IPFIX Protocol for Detection of Distributed Denial of Service Attacks against Cloud Infrastructure

    Directory of Open Access Journals (Sweden)

    M. R. Mukhtarov

    2011-12-01

    Full Text Available The way of monitoring deviations in network traffic behavior inside “Cloud Infrastructure” using IPFIX protocol is suggested in the paper. The proposed algorithm is applied for registration of “Distributed Denial of Service” attacks against “Cloud Infrastructure”.

  3. Development of protocols to inventory or monitor wildlife, fish, or rare plants

    Science.gov (United States)

    David Vesely; Brenda C. McComb; Christina D. Vojta; Lowell H. Suring; Jurai Halaj; Richard S. Holthausen; Benjamin Zuckerberg; Patricia M. Manley

    2006-01-01

    The purpose of this technical guide (hereafter referred to as the Species Protocol Technical Guide) is to provide guidelines for developing inventory and monitoring (I&M) protocols for wildlife, fish, and rare plants (WFRP) using the U.S. Department of Agriculture (USDA) Forest Service technical guide format.

  4. Two-Layer Hierarchy Optimization Model for Communication Protocol in Railway Wireless Monitoring Networks

    Directory of Open Access Journals (Sweden)

    Xiaoping Ma

    2018-01-01

    Full Text Available The wireless monitoring system is always destroyed by the insufficient energy of the sensors in railway. Hence, how to optimize the communication protocol and extend the system lifetime is crucial to ensure the stability of system. However, the existing studies focused primarily on cluster-based or multihop protocols individually, which are ineffective in coping with the complex communication scenarios in the railway wireless monitoring system (RWMS. This study proposes a hybrid protocol which combines the cluster-based and multihop protocols (CMCP to minimize and balance the energy consumption in different sections of the RWMS. In the first hierarchy, the total energy consumption is minimized by optimizing the cluster quantities in the cluster-based protocol and the number of hops and the corresponding hop distances in the multihop protocol. In the second hierarchy, the energy consumption is balanced through rotating the cluster head (CH in the subnetworks and further optimizing the hops and the corresponding hop distances in the backbone network. On this basis, the system lifetime is maximized with the minimum and balance energy consumption among the sensors. Furthermore, the hybrid particle swarm optimization and genetic algorithm (PSO-GA are adopted to optimize the energy consumption from the two-layer hierarchy. Finally, the effectiveness of the proposed CMCP is verified in the simulation. The performances of the proposed CMCP in system lifetime, residual energy, and the corresponding variance are all superior to the LEACH protocol widely applied in the previous research. The effective protocol proposed in this study can facilitate the application of the wireless monitoring network in the railway system and enhance safety operation of the railway.

  5. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    Science.gov (United States)

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  6. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    Science.gov (United States)

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  7. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    Science.gov (United States)

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  8. Protocol for Monitoring Fish Assemblages in Pacific Northwest National Parks

    Science.gov (United States)

    Brenkman, Samuel J.; Connolly, Patrick J.

    2008-01-01

    Rivers and streams that drain from Olympic, Mount Rainier, and North Cascades National Parks are among the most protected corridors in the lower 48 States, and represent some of the largest tracts of contiguous, undisturbed habitat throughout the range of several key fish species of the Pacific Northwest. These watersheds are of high regional importance as freshwater habitat sanctuaries for native fish, where habitat conditions are characterized as having little to no disturbance from development, channelization, impervious surfaces, roads, diversions, or hydroelectric projects. Fishery resources are of high ecological and cultural importance in Pacific Northwest National Parks, and significantly contribute to economically important recreational, commercial, and tribal fisheries. This protocol describes procedures to monitor trends in fish assemblages, fish abundance, and water temperature in eight rivers and five wadeable streams in Olympic National Park during summer months, and is based on 4 years of field testing. Fish assemblages link freshwater, marine, and terrestrial ecosystems. They also serve as focal resources of national parks and are excellent indicators of ecological conditions of rivers and streams. Despite the vital importance of native anadromous and resident fish populations, there is no existing monitoring program for fish assemblages in the North Coast and Cascades Network. Specific monitoring objectives of this protocol are to determine seasonal and annual trends in: (1) fish species composition, (2) timing of migration of adult fish, (3) relative abundance, (4) age and size structure, (5) extent of non-native and hatchery fish, and (6) water temperature. To detect seasonal and annual trends in fish assemblages in reference sites, we rely on repeated and consistent annual sampling at each monitoring site. The general rationale for the repeated sampling of reference sites is to ensure that we account for the high interannual variability in fish

  9. Protocol to monitor trade agreement food-related aspects: the Fiji case study.

    Science.gov (United States)

    Ravuvu, Amerita; Friel, Sharon; Thow, Anne Marie; Snowdon, Wendy; Wate, Jillian

    2017-04-26

    Despite the growing rates of obesity and diet-related non-communicable diseases, globally, public health attention has only relatively recently turned to the links between trade agreements and the nutritional risks associated with it. Specific trade agreements appear to have played an influential role in the volume and types of foods entering different countries, yet there is currently no systematic and objective monitoring of trade agreements for their impacts on food environments. Recently, INFORMAS was set up to monitor and benchmark food environments, government policies and private sector actions within countries and globally. One of its projects/modules focuses on trade policy and in particular the food-related aspects of trade agreements. This paper describes the INFORMAS trade protocol, an approach to collecting food-related information about four domains of trade: trade in goods; trade in services and foreign direct investment; domestic supports, and policy space. Specifically, the protocol is tested in Fiji. The development and testing of this protocol in Fiji represents the first effort to set out a framework and process for objectively monitoring trade agreements and their impacts on national food supply and the wider food environment. It has shown that entry into WTO trade agreements contributed to the nutrition transition in Fiji through the increased availability of imported foods with varying nutritional quality. We observed an increase in imports of both healthy and less healthy foods. The application of the monitoring protocol also highlights challenges for data collection associated with each trade domain that should be considered for future data collection and analysis in other low and middle income countries. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. A global protocol for monitoring of coral bleaching

    OpenAIRE

    Oliver, J.; Setiasih, N.; Marshall, P.; Hansen, L.

    2004-01-01

    Coral bleaching and subsequent mortality represent a major threat to the future health and productivity of coral reefs. However a lack of reliable data on occurrence, severity and other characteristics of bleaching events hampers research on the causes and consequences of this important phenomenon. This article describes a global protocol for monitoring coral bleaching events, which addresses this problem and can be used by people with different levels of expertise and resources.

  11. Investigating Long-Term Monitoring Protocols in support of Quivira NWR Habitat Objectives

    Data.gov (United States)

    Department of the Interior — The project purpose is to investigate long-term monitoring protocols in support of Quivira NWR habitat objectives as described in the Refuge’s recently approved CCP...

  12. ST-segment deviation during 24-hour ambulatory electrocardiographic monitoring and exercise stress test in healthy male subjects 51 to 75 years of age: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Sørum, C

    1999-01-01

    or descending ST-segment depression of >/=0.15 mV during Holter monitoring or at the exercise test, respectively. Furthermore, the specificity was 0.95 when a horizontal or downsloping ST-segment depression of 0.1 mV was displayed in both the Holter and exercise electrocardiographic recording system......BACKGROUND: Although ST-segment deviation has been evaluated and used during many years both on continuous electrocardiographic Holter monitoring and during exercise stress testing, considerable controversy still remains concerning the prevalence and diagnostic significance of fortuitously...... discovered ST-segment deviation in asymptomatic healthy persons. METHODS AND RESULTS: The occurrence of ST-segment deviation was studied in a population of 63 clinically healthy male subjects 51 to 75 years of age, with the use of 24-hour Holter monitoring and exercise stress testing. The subjects were...

  13. Indicators and protocols for monitoring impacts of formal and informal trails in protected areas

    Science.gov (United States)

    Marion, Jeffrey L.; Leung, Yu-Fai

    2011-01-01

    Trails are a common recreation infrastructure in protected areas and their conditions affect the quality of natural resources and visitor experiences. Various trail impact indicators and assessment protocols have been developed in support of monitoring programs, which are often used for management decision-making or as part of visitor capacity management frameworks. This paper reviews common indicators and assessment protocols for three types of trails, surfaced formal trails, unsurfaced formal trails, and informal (visitor-created) trails. Monitoring methods and selected data from three U.S. National Park Service units are presented to illustrate some common trail impact indicators and assessment options.

  14. Protocol Monitoring Passive Solar Energy

    International Nuclear Information System (INIS)

    Van den Ham, E.R.; Bosselaar, L.

    1998-01-01

    A method has been developed by means of which the contribution of passive solar energy to the Dutch energy balance can be quantified univocally. The contribution was 57 PJ in 1990 and also 57 PJ in 1995. The efficiency of passive solar energy systems increased from -31.5% to -28.1% in the period 1990-1995, mainly as a result of the use of extra insulating glazing. As a result of the reduction of energy consumption for heating in houses it is expected that the extra contribution of 2 PJ will not be realized in the year 2010. It is suggested that the method to determine the absolute contribution of passive solar energy to the energy demand of dwellings is to be included in the protocol monitoring renewable energy. For the method to be included in the energy statistics of Statistics Netherlands (CBS) it can be considered only to take into account the difference compared to 1990. 11 refs

  15. A reliable transmission protocol for ZigBee-based wireless patient monitoring.

    Science.gov (United States)

    Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung

    2012-01-01

    Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

  16. An Ad-Hoc Opportunistic Dissemination Protocol for Smartphone-based Participatory Traffic Monitoring

    NARCIS (Netherlands)

    Türkes, Okan; Seraj, Fatjon; Scholten, Johan; Meratnia, Nirvana; Havinga, Paul J.M.

    2015-01-01

    This study introduces an ad-hoc opportunistic data dissemination protocol, called VADISS, that facilitates participatory traffic monitoring applications with smartphones. As a ubiquitous alternative to existing vehicular networking methods, VADISS uses the default WiFi interfaces universally adopted

  17. Improvement in QA protocol for TLD based personnel monitoring laboratory in last five year

    International Nuclear Information System (INIS)

    Rakesh, R.B.

    2018-01-01

    The Quality Assurance (QA) in Personnel monitoring (PM) is a tool to assess the performance of PM laboratories and reliability of dose estimation with respect to standards laid down by international agencies such as IAEA (ISO trumpet curve), IEC, ANSI etc. Reliable personal dose estimation is a basic requirement for radiation protection planning as well as decision making continuous improvement in radiation protection is inherent in radiation protection practices which is highly dependent on accuracy and reliability of the monitoring data. Experience based evolution of Quality control (QC) measures as well as Quality assurance (QA) protocol are two important aspects towards continuous improvement in accuracy and reliability of personnel monitoring results. The paper describes improvement in QC measures and QA protocols initiated during the last five years which led to improvement in the quality of PM services

  18. The radiological monitoring protocol for metallic products and cleared scrap management

    International Nuclear Information System (INIS)

    Gil Lopez, E.

    2003-01-01

    Event though the use of nuclear and radiological techniques is subject to strict controls in most countries, the presence of radioactive material in batches of metallic scrap has been detected with relative frequency in the last few years. This circumstance has motivated the implementation of a series of national and international initiatives aimed at detecting and preventing this type of events, whether they be intentional or involuntary. The Spanish iron and steel industry is one of the country's most important industrial sectors, and to a great extent it depends on the importation of a very significant amount of metallic scrap that it uses as raw material. Experience has shown that countries that import large amounts of scrap, apart from supporting the mentioned international initiatives, should complement them with other national initiatives to reduce the risks resulting from the presence of radioactive material in scrap. In this context, the Spanish authorities, together with trade unions and entrepreneurial associations in the metal reclamations and smelting sectors and ENRESA, have signed a voluntary Protocol that defines and implements a national radiological monitoring and control system for scrap materials and their byproducts. The Protocol defines the obligations and rights of the signatories, and it describes the monitoring and control system and its legal bases, the operation of both specific and other general-purpose radiological monitoring equipment that existed prior to this initiative, the development of radiological training and dissemination plans for professionals in the metal reclamation and smelting sectors, the establishment of effective systems for the safe management of any radioactive materials detected, and the general improvement of the national response system in the event of radiological emergencies. Since the Protocol took effect in November 1999, more than 100 enterprises from the metallurgical (steel, copper, lead and aluminum

  19. Phase Transition in Protocols Minimizing Work Fluctuations

    Science.gov (United States)

    Solon, Alexandre P.; Horowitz, Jordan M.

    2018-05-01

    For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.

  20. Protocol of specific health monitoring: ionizing radiation, 11 years later

    International Nuclear Information System (INIS)

    Castillejo Puertas, F. M.

    2016-01-01

    Since the approval on November 11 t h 2003 of the Protocol of Specific Health Monitoring for Workers Exposed to Ionizing Radiation a study has been carried out to discover its effectiveness. These areas were examined: the daily practice od accupational medicine and, in particular, its specific task in the application of the different clinical/labour criteria for workers exposed to ionizing radiation or at risk of radioactive contamination; the degree of its uses as well as the updates and improvements. For that purpose, a descriptive bibliographic revision has been used for the last 11 years. The results revealed the lack of updates of the Protocol as well as the few usable objective criteria, when the clinical/labour aptitudes are reflected upon. (Author)

  1. EMS Adherence to a Pre-hospital Cervical Spine Clearance Protocol

    Directory of Open Access Journals (Sweden)

    Johnson, David

    2001-10-01

    Full Text Available Purpose: To determine the degree of adherence to a cervical spine (c-spine clearance protocol by pre-hospital Emergency Medical Services (EMS personnel by both self-assessment and receiving hospital assessment, to describe deviations from the protocol, and to determine if the rate of compliance by paramedic self-assessment differed from receiving hospital assessment. Methods: A retrospective sample of pre-hospital (consecutive series and receiving hospital (convenience sample assessments of the compliance with and appropriateness of c-spine immobilization. The c-spine clearance protocol was implemented for Orange County EMS just prior to the April-November 1999 data collection period. Results: We collected 396 pre-hospital and 162 receiving hospital data forms. From the pre-hospital data sheet. the percentage deviation from the protocol was 4.096 (16/396. Only one out of 16 cases that did not comply with the protocol was due to over immobilization (0.2%. The remaining 15 cases were under immobilized, according to protocol. Nine of the under immobilized cases (66% that should have been placed in c-spine precautions met physical assessment criteria in the protocol, while the other five cases met mechanism of injury criteria. The rate of deviations from protocol did not differ over time. The receiving hospital identified 8.0% (13/162; 6/16 over immobilized, 7/16 under immobilized of patients with deviations from the protocol; none was determined to have actual c-spine injury. Conclusion: The implementation of a pre-hospital c-spine clearance protocol in Orange County was associated with a moderate overall adherence rate (96% from the pre-hospital perspective, and 92% from the hospital perspective, p=.08 for the two evaluation methods. Most patients who deviated from protocol were under immobilized, but no c-spine injuries were missed. The rate of over immobilization was better than previously reported, implying a saving of resources.

  2. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study.

    Science.gov (United States)

    Lauzier, F; Adhikari, N K; Seely, A; Koo, K K Y; Belley-Côté, E P; Burns, K E A; Cook, D J; D'Aragon, F; Rochwerg, B; Kho, M E; Oczkowksi, S J W; Duan, E H; Meade, M O; Day, A G; Lamontagne, F

    2017-07-17

    The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75-80 mmHg) versus lower (60-65 mmHg) mean arterial pressure (MAP) targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated with between-arm separation, if it can be measured.

  3. A Novel Smart Routing Protocol for Remote Health Monitoring in Medical Wireless Networks

    Directory of Open Access Journals (Sweden)

    T. V. P. Sundararajan

    2014-01-01

    Full Text Available In a Medical Wireless Network (MWN, sensors constantly monitor patient's physiological condition and movement. Inter-MWN communications are set up between the Patient Server and one or more Centralized Coordinators. However, MWNs require protocols with little energy consumption and the self-organizing attribute perceived in ad-hoc networks. The proposed Smart Routing Protocol (SRP selects only the nodes with a higher residual energy and lower traffic density for routing. This approach enhances cooperation among the nodes of a Mobile Ad Hoc Network. Consequently, SRP produces better results than the existing protocols, namely Conditional Min-Max Battery Cost Routing, Min-Max Battery Cost Routing and AdHoc On-demand Distance Vector in terms of network parameters. The performance of the erstwhile schemes for routing protocols is evaluated using the network simulator Qualnet v 4.5.

  4. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study

    Directory of Open Access Journals (Sweden)

    F. Lauzier

    2017-07-01

    Full Text Available Abstract Background The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Discussion Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75–80 mmHg versus lower (60–65 mmHg mean arterial pressure (MAP targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. Conclusions In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated

  5. Realization of Intelligent Household Appliance Wireless Monitoring Network Based on LEACH Protocol

    Directory of Open Access Journals (Sweden)

    Weilong ZHOU

    2014-06-01

    Full Text Available The intelligent household appliance wireless monitoring network can real-time monitor the apparent power and power factor of various household appliances in different indoor regions, and can realize the real-time monitoring on the household appliance working status and performance. The household appliance wireless monitoring network based on LEACH protocol is designed in the paper. Firstly, the basic idea of LEACH routing algorithm is proposed. Aiming at the node-distribution feature of intelligent home, the selection of cluster head in the routing algorithm and the data transmission method at the stable communication phase is modified. Moreover, the hardware circuit of power acquisition and power factor measurement is designed. The realization of wireless monitoring network based on CC2530 is described, each module and the whole system were conducted the on-line debugging. Finally, the system is proved to meet the practical requirement through the networking test.

  6. Protocols for Monitoring Habitat Restoration Projects in the Lower Columbia River and Estuary

    Energy Technology Data Exchange (ETDEWEB)

    Roegner, G. Curtis; Diefenderfer, Heida L.; Borde, Amy B.; Thom, Ronald M.; Dawley, Earl M.; Whiting, Allan H.; Zimmerman, Shon A.; Johnson, Gary E.

    2008-04-25

    Protocols for monitoring salmon habitat restoration projects are essential for the U.S. Army Corps of Engineers' environmental efforts in the Columbia River estuary. This manual provides state-of-the science data collection and analysis methods for landscape features, water quality, and fish species composition, among others.

  7. Channel Deviation-Based Power Control in Body Area Networks.

    Science.gov (United States)

    Van, Son Dinh; Cotton, Simon L; Smith, David B

    2018-05-01

    Internet enabled body area networks (BANs) will form a core part of future remote health monitoring and ambient assisted living technology. In BAN applications, due to the dynamic nature of human activity, the off-body BAN channel can be prone to deep fading caused by body shadowing and multipath fading. Using this knowledge, we present some novel practical adaptive power control protocols based on the channel deviation to simultaneously prolong the lifetime of wearable devices and reduce outage probability. The proposed schemes are both flexible and relatively simple to implement on hardware platforms with constrained resources making them inherently suitable for BAN applications. We present the key algorithm parameters used to dynamically respond to the channel variation. This allows the algorithms to achieve a better energy efficiency and signal reliability in everyday usage scenarios such as those in which a person undertakes many different activities (e.g., sitting, walking, standing, etc.). We also profile their performance against traditional, optimal, and other existing schemes for which it is demonstrated that not only does the outage probability reduce significantly, but the proposed algorithms also save up to average transmit power compared to the competing schemes.

  8. PMT Dark Noise Monitoring System for Neutrino Detector Borexino Based on the Devicenet Protocol and WEB-Access

    International Nuclear Information System (INIS)

    Chepurnov, A.S.; Orekhov, D.I.; Maimistov, D.A.; Sabelnikov, A.A.; Etenko, A.V.

    2006-01-01

    Monitoring of PMT dark noise in a neutrino detector BOREXINO is a procedure that indicates condition of the detector. Based on CAN industrial network, top level DeviceNet protocol and WEB visualization, the dark noise monitoring system having 256 channels for the internal detector and for the external muon veto was created. The system is composed as a set of controllers, converting the PMT signals to frequency and transmitting them over Can network. The software is the stack of the DeviceNet protocols, providing the data collecting and transporting. Server-side scripts build web pages of user interface and graphical visualization of data

  9. Large deviations

    CERN Document Server

    Varadhan, S R S

    2016-01-01

    The theory of large deviations deals with rates at which probabilities of certain events decay as a natural parameter in the problem varies. This book, which is based on a graduate course on large deviations at the Courant Institute, focuses on three concrete sets of examples: (i) diffusions with small noise and the exit problem, (ii) large time behavior of Markov processes and their connection to the Feynman-Kac formula and the related large deviation behavior of the number of distinct sites visited by a random walk, and (iii) interacting particle systems, their scaling limits, and large deviations from their expected limits. For the most part the examples are worked out in detail, and in the process the subject of large deviations is developed. The book will give the reader a flavor of how large deviation theory can help in problems that are not posed directly in terms of large deviations. The reader is assumed to have some familiarity with probability, Markov processes, and interacting particle systems.

  10. The relationship between ST segment deviation projected to the front of the chest during exercise and simultaneous Holter monitoring

    DEFF Research Database (Denmark)

    Egstrup, K

    1988-01-01

    were placed to correspond to CM5 and an aVF-like lead. In 36 patients, ST segment changes were found with both Holter and the 12-lead precordial electrocardiogram, while in 12 patients no ischaemic changes were detected by either method. Thus the results of the two methods concurred in 48 of 50 patient...... (96%). The magnitude of the ischaemic change was similar in 24 of 36 patients (67%), while the Holter system underestimated the ischaemic change by 0.5-2.0 mm in 12 patients. When the maximal ST segment deviation in V5 was compared with CM5, the deviations with both systems were identical in all...... but one patient in whom a difference of 0.5 mm was found. The use of a Holter lead resembling a VF identified maximal ST segment change on only one occasion, and in only four patients was an ST segment change of 1 mm noted. In conclusion, ambulatory monitoring utilizing only CM5 seems to detect most...

  11. Voice deviation, dysphonia risk screening and quality of life in individuals with various laryngeal diagnoses

    Science.gov (United States)

    Nemr, Katia; Cota, Ariane; Tsuji, Domingos; Simões-Zenari, Marcia

    2018-01-01

    OBJECTIVES: To characterize the voice quality of individuals with dysphonia and to investigate possible correlations between the degree of voice deviation (D) and scores on the Dysphonia Risk Screening Protocol-General (DRSP), the Voice-Related Quality of Life (V-RQOL) measure and the Voice Handicap Index, short version (VHI-10). METHODS: The sample included 200 individuals with dysphonia. Following laryngoscopy, the participants completed the DRSP, the V-RQOL measure, and the VHI-10; subsequently, voice samples were recorded for auditory-perceptual and acoustic analyses. The correlation between the score for each questionnaire and the overall degree of vocal deviation was analyzed, as was the correlation among the scores for the three questionnaires. RESULTS: Most of the participants (62%) were female, and the mean age of the sample was 49 years. The most common laryngeal diagnosis was organic dysphonia (79.5%). The mean D was 59.54, and the predominance of roughness had a mean of 54.74. All the participants exhibited at least one abnormal acoustic aspect. The mean questionnaire scores were DRSP, 44.7; V-RQOL, 57.1; and VHI-10, 16. An inverse correlation was found between the V-RQOL score and D; however, a positive correlation was found between both the VHI-10 and DRSP scores and D. CONCLUSION: A predominance of adult women, organic dysphonia, moderate voice deviation, high dysphonia risk, and low to moderate quality of life impact characterized our sample. There were correlations between the scores of each of the three questionnaires and the degree of voice deviation. It should be noted that the DRSP monitored the degree of dysphonia severity, which reinforces its applicability for patients with different laryngeal diagnoses. PMID:29538494

  12. Design and analysis of control charts for standard deviation with estimated parameters

    NARCIS (Netherlands)

    Schoonhoven, M.; Riaz, M.; Does, R.J.M.M.

    2011-01-01

    This paper concerns the design and analysis of the standard deviation control chart with estimated limits. We consider an extensive range of statistics to estimate the in-control standard deviation (Phase I) and design the control chart for real-time process monitoring (Phase II) by determining the

  13. Prairie Monitoring Protocol Development: North Coast and Cascades Network

    Science.gov (United States)

    McCoy, Allen; Dalby, Craig

    2009-01-01

    The purpose of the project was to conduct research that will guide development of a standard approach to monitoring several components of prairies within the North Coast and Cascades Network (NCCN) parks. Prairies are an important element of the natural environment at many parks, including San Juan Island National Historical Park (NHP) and Ebey's Landing National Historical Reserve (NHR). Forests have been encroaching on these prairies for many years, and so monitoring of the prairies is an important resource issue. This project specifically focused on San Juan Island NHP. Prairies at Ebey's Landing NHR will be monitored in the future, but that park was not mapped as part of this prototype project. In the interest of efficiency, the Network decided to investigate two main issues before launching a full protocol development effort: (1) the imagery requirements for monitoring prairie components, and (2) the effectiveness of software to assist in extracting features from the imagery. Several components of prairie monitoring were initially identified as being easily tracked using aerial imagery. These components included prairie/forest edge, broad prairie composition (for example, shrubs, scattered trees), and internal exclusions (for example, shrubs, bare ground). In addition, we believed that it might be possible to distinguish different grasses in the prairies if the imagery were of high enough resolution. Although the areas in question at San Juan Island NHP are small enough that mapping on the ground with GPS (Global Positioning System) would be feasible, other applications could benefit from aerial image acquisition on a regular, recurring basis and thereby make the investment in aerial imagery worthwhile. The additional expense of orthorectifying the imagery also was determined to be cost-effective.

  14. Rivers rapid assessment protocols and insertion of society in monitoring of water resources

    Directory of Open Access Journals (Sweden)

    Guilherme Malafaia

    2008-12-01

    Full Text Available The degradation of water resources has been detected and changes both institutional and in the legislation have been demanded. The careless use of rivers has ecological changes as direct consequence, causing serious modifications in the landscape and fluvial regime, besides altering the availability of habitats and the trophic composition of the aquatic environment. Pressed by this scenario, scientists have been developing assessment methods that are efficient both for the evaluation itself and for supporting decision taking in the environmental management processes. In this perspective, the objective of this study is to present the Rapid River Assessment Protocols (RAPs and to emphasize how these protocols can promote the community participation in water resources monitoring. The RAPs can used to evaluate in an integrated form the characteristics of a river section according to the conservation or degradation condition of the fluvial environment and it is characterized by its economic viability and easy applicability. In regions with poor financial resources and serious problems of water quality, the RAPs can be used in environmental management programs. By using these protocols, the integration of the community in water resources monitoring generates data which represent the quality of fluvial ecosystems throughout time, without requesting high costs or specialized professionals. The RAPs in a simplified but not simplistic tool, which can be used in activities that aim at promoting a quick and reliable assessment of the “health” of a river.

  15. A Group Neighborhood Average Clock Synchronization Protocol for Wireless Sensor Networks

    Science.gov (United States)

    Lin, Lin; Ma, Shiwei; Ma, Maode

    2014-01-01

    Clock synchronization is a very important issue for the applications of wireless sensor networks. The sensors need to keep a strict clock so that users can know exactly what happens in the monitoring area at the same time. This paper proposes a novel internal distributed clock synchronization solution using group neighborhood average. Each sensor node collects the offset and skew rate of the neighbors. Group averaging of offset and skew rate value are calculated instead of conventional point-to-point averaging method. The sensor node then returns compensated value back to the neighbors. The propagation delay is considered and compensated. The analytical analysis of offset and skew compensation is presented. Simulation results validate the effectiveness of the protocol and reveal that the protocol allows sensor networks to quickly establish a consensus clock and maintain a small deviation from the consensus clock. PMID:25120163

  16. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy

    International Nuclear Information System (INIS)

    Higashigaito, K.; Becker, A.S.; Sprengel, K.; Simmen, H.-P.; Wanner, G.; Alkadhi, H.

    2016-01-01

    Aim: To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). Materials and methods: In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current–time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current–time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Results: Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDI_v_o_l; p=0.62), dose–length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both −38%, p<0.017). Compared to cohort 1, CTDI_v_o_l, DLP, and ED in cohort 3 were significantly lower (all −25%, p<0.017), similar to the noise in the chest (–32%) and abdomen (–27%, both p<0.017). Compared to cohort 2, CTDI_v_o_l (–28%), DLP, and ED (both –26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Conclusion: Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. - Highlights: • Automatic dose monitoring software can be

  17. Ecological thresholds in the savanna landscape: developing a protocol for monitoring the change in composition and utilisation of large trees.

    Directory of Open Access Journals (Sweden)

    Dave J Druce

    Full Text Available BACKGROUND: Acquiring greater understanding of the factors causing changes in vegetation structure -- particularly with the potential to cause regime shifts -- is important in adaptively managed conservation areas. Large trees (> or =5 m in height play an important ecosystem function, and are associated with a stable ecological state in the African savanna. There is concern that large tree densities are declining in a number of protected areas, including the Kruger National Park, South Africa. In this paper the results of a field study designed to monitor change in a savanna system are presented and discussed. METHODOLOGY/PRINCIPAL FINDINGS: Developing the first phase of a monitoring protocol to measure the change in tree species composition, density and size distribution, whilst also identifying factors driving change. A central issue is the discrete spatial distribution of large trees in the landscape, making point sampling approaches relatively ineffective. Accordingly, fourteen 10 m wide transects were aligned perpendicular to large rivers (3.0-6.6 km in length and eight transects were located at fixed-point photographic locations (1.0-1.6 km in length. Using accumulation curves, we established that the majority of tree species were sampled within 3 km. Furthermore, the key ecological drivers (e.g. fire, herbivory, drought and disease which influence large tree use and impact were also recorded within 3 km. CONCLUSIONS/SIGNIFICANCE: The technique presented provides an effective method for monitoring changes in large tree abundance, size distribution and use by the main ecological drivers across the savanna landscape. However, the monitoring of rare tree species would require individual marking approaches due to their low densities and specific habitat requirements. Repeat sampling intervals would vary depending on the factor of concern and proposed management mitigation. Once a monitoring protocol has been identified and evaluated, the next

  18. A Group Neighborhood Average Clock Synchronization Protocol for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Lin Lin

    2014-08-01

    Full Text Available Clock synchronization is a very important issue for the applications of wireless sensor networks. The sensors need to keep a strict clock so that users can know exactly what happens in the monitoring area at the same time. This paper proposes a novel internal distributed clock synchronization solution using group neighborhood average. Each sensor node collects the offset and skew rate of the neighbors. Group averaging of offset and skew rate value are calculated instead of conventional point-to-point averaging method. The sensor node then returns compensated value back to the neighbors. The propagation delay is considered and compensated. The analytical analysis of offset and skew compensation is presented. Simulation results validate the effectiveness of the protocol and reveal that the protocol allows sensor networks to quickly establish a consensus clock and maintain a small deviation from the consensus clock.

  19. PA.NET International Quality Certification Protocol for blood pressure monitors.

    Science.gov (United States)

    Omboni, Stefano; Costantini, Carlo; Pini, Claudio; Bulegato, Roberto; Manfellotto, Dario; Rizzoni, Damiano; Palatini, Paolo; O'brien, Eoin; Parati, Gianfranco

    2008-10-01

    Although standard validation protocols provide assurance of the accuracy of blood pressure monitors (BPMs), there is no guidance for the consumer as to the overall quality of a device. The PA.NET International Quality Certification Protocol, developed by the Association for Research and Development of Biomedical Technologies and for Continuing Medical Education (ARSMED), a nonprofit organization, with the support of the Italian Society of Hypertension-Italian Hypertension League, and the dabl Educational Trust denotes additional criteria of quality for BPMs that fulfilled basic validation criteria, published in full in peer-reviewed medical journals. The certification is characterized by three phases: (i) to determine that the device fulfilled standard validation criteria; (ii) to determine the technical and functional characteristics of the device (e.g. operativity, display dimension, accessory functions, memory availability, etc.) and (iii) to determine the commercial characteristics (e.g. price-quality ratio, after-sale service, guarantee, etc.). At the end of the certification process, ARSMED attributes a quality index to the device, based on a scale ranging from 1 to 100, and a quality seal with four different grades (bronze, silver, gold and diamond) according to the achieved score. The seal is identified by a unique alphanumeric code. The quality seal may be used on the packaging of the appliance or in advertising. A quality certification is released to the manufacturer and published on www.pressionearteriosa.net and www.dableducational.org. The PA.NET International Quality Certification Protocol represents the first attempt to provide health care personnel and consumers with an independent and objective assessment of BPMs based on their quality.

  20. Changes in deviation of absorbed dose to water among users by chamber calibration shift.

    Science.gov (United States)

    Katayose, Tetsurou; Saitoh, Hidetoshi; Igari, Mitsunobu; Chang, Weishan; Hashimoto, Shimpei; Morioka, Mie

    2017-07-01

    The JSMP01 dosimetry protocol had adopted the provisional 60 Co calibration coefficient [Formula: see text], namely, the product of exposure calibration coefficient N C and conversion coefficient k D,X . After that, the absorbed dose to water D w  standard was established, and the JSMP12 protocol adopted the [Formula: see text] calibration. In this study, the influence of the calibration shift on the measurement of D w among users was analyzed. The intercomparison of the D w using an ionization chamber was annually performed by visiting related hospitals. Intercomparison results before and after the calibration shift were analyzed, the deviation of D w among users was re-evaluated, and the cause of deviation was estimated. As a result, the stability of LINAC, calibration of the thermometer and barometer, and collection method of ion recombination were confirmed. The statistical significance of standard deviation of D w was not observed, but that of difference of D w among users was observed between N C and [Formula: see text] calibration. Uncertainty due to chamber-to-chamber variation was reduced by the calibration shift, consequently reducing the uncertainty among users regarding D w . The result also pointed out uncertainty might be reduced by accurate and detailed instructions on the setup of an ionization chamber.

  1. Informal and formal trail monitoring protocols and baseline conditions: Acadia National Park

    Science.gov (United States)

    Marion, Jeffrey L.; Wimpey, Jeremy F.; Park, L.

    2011-01-01

    At Acadia National Park, changing visitor use levels and patterns have contributed to an increasing degree of visitor use impacts to natural and cultural resources. To better understand the extent and severity of these resource impacts and identify effective management techniques, the park sponsored this research to develop monitoring protocols, collect baseline data, and identify suggestions for management strategies. Formal and informal trails were surveyed and their resource conditions were assessed and characterized to support park planning and management decision-making.

  2. ADNP-CSMA Random Multiple Access protocol application with the function of monitoring in Ad Hoc network

    Directory of Open Access Journals (Sweden)

    Zhan Gang

    2016-01-01

    Full Text Available In Ad Hoc networks,the net work of mobile nodes exchange information with their wireless transceiver equipment,the network throughput is in increased,compared to other such multiple hops network.Moreover along with the rapid development of modern information,communication business also will be increase.However,the access and adaptive of previous CSMA protocol are insufficient.According to these properties,this paper presents a kind of adaptive dual clock with monitoring function P-CSMA random multiple access protocol(ADNP-CSMA,and discusses two kinds of P-CSMA.ACK with monitoring function is introduced to maintain the stability of the whole system,and the introduction of dual clock mechanism reduces the channel of idle period.It calculate the system throughput expression through the method of average period,and the simulation results show that the system is constant in the case of high load throughput.

  3. Elk Monitoring Protocol for Lewis and Clark National Historical Park, Version 1.0

    Science.gov (United States)

    Jenkins, Kurt J.; Griffin, Paul C.; Boetsch, John R.; Cole, Carla

    2011-01-01

    Maintaining elk (Cervus elaphus roosevelti) herds that frequent Lewis and Clark National Historical Park (NHP) is central to the park’s purpose of preserving the historic, cultural, scenic, and natural resources. Elk were critical to sustaining the members of the Lewis and Clark expedition by providing food and clothing over the winter of 1805-1806. Today, elk viewing opportunities in the park and surrounding region generate broad appeal with the visiting public, which number over 250,000 per year at the Fort Clatsop visitor center. This protocol describes procedures for monitoring trends in the use of the Fort Clatsop area by Roosevelt elk. Specific objectives of elk monitoring in Lewis and Clark NHP are to measure the relative use and proportion of area used by elk during winter in the Fort Clatsop Unit of the park, and the rate at which elk are sighted from roads in and around the park. Relative use and the proportion of area used by elk are determined from elk fecal pellet surveys conducted every other year in the Fort Clatsop park unit. Pairs of observers visit a systematic array of permanent plots in the fall to clear them of elk fecal pellets, and return to the plots in late winter to count elk fecal pellets that have accumulated during winter. Half of the subplots are counted by two independent observers, which allows for the estimation of relative use and proportion of area occupied by elk with analyses of detection biases that account for unseen elk pellet groups. Standardized road surveys are conducted in and near the Fort Clatsop park unit three or four times monthly during alternate months. Data from road surveys are used to quantify the rate that park visitors would be expected to see elk, when driving the selected set of routes. The monitoring protocol is based on three field seasons of development and testing. The protocol narrative describes the background, rationale, sampling design, field methods, analytical methods, data management, reporting

  4. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  5. The Hawaii protocol for scientific monitoring of coffee berry borer: a model for coffee agroecosystems worldwide

    Science.gov (United States)

    Coffee Berry Borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape...

  6. RadNet: Open network protocol for radiation data

    International Nuclear Information System (INIS)

    Rees, B.; Olson, K.; Beckes-Talcott, J.; Kadner, S.; Wenderlich, T.; Hoy, M.; Doyle, W.; Koskelo, M.

    1998-01-01

    Safeguards instrumentation is increasingly being incorporated into remote monitoring applications. In the past, vendors of radiation monitoring instruments typically provided the tools for uploading the monitoring data to a host. However, the proprietary nature of communication protocols lends itself to increased computer support needs and increased installation expenses. As a result, a working group of suppliers and customers of radiation monitoring instruments defined an open network protocol for transferring packets on a local area network from radiation monitoring equipment to network hosts. The protocol was termed RadNet. While it is now primarily used for health physics instruments, RadNet's flexibility and strength make it ideal for remote monitoring of nuclear materials. The incorporation of standard, open protocols ensures that future work will not render present work obsolete; because RadNet utilizes standard Internet protocols, and is itself a non-proprietary standard. The use of industry standards also simplifies the development and implementation of ancillary services, e.g. E-main generation or even pager systems

  7. A protocol using coho salmon to monitor Tongass National Forest Land and Resource Management Plan standards and guidelines for fish habitat.

    Science.gov (United States)

    M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl

    2008-01-01

    We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...

  8. Importance of borehole deviation surveys for monitoring of hydraulic fracturing treatments

    Czech Academy of Sciences Publication Activity Database

    Bulant, P.; Eisner, L.; Pšenčík, Ivan; Le Calvez, J. H.

    2007-01-01

    Roč. 55, č. 6 (2007), s. 891-899 ISSN 0016-8025 Grant - others:GA ČR(CZ) GA205/07/0032; EC(XE) MTKI-CT-2004-517242 Institutional research plan: CEZ:AV0Z30120515 Source of funding: R - rámcový projekt EK Keywords : hydraulic fracture * borehole deviation * seismic rays Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.731, year: 2007

  9. Data-Based Energy Efficient Clustered Routing Protocol for Wireless Sensors Networks – Tabuk Flood Monitoring System Case Study

    Directory of Open Access Journals (Sweden)

    Ammar Babiker

    2017-10-01

    Full Text Available Energy efficiency has been considered as the most important issue in wireless sensor networks. As in many applications, wireless sensors are scattered in a wide harsh area, where the battery replacement or charging will be quite difficult and it is the most important challenge. Therefore, the design of energy saving mechanism becomes mandatory in most recent research. In this paper, a new energy efficient clustered routing protocol is proposed: the proposed protocol is based on analyzing the data collected from the sensors in a base-station. Based on this analysis the cluster head will be selected as the one with the most useful data. Then, a variable time slot is specified to each sensor to minimize the transmission of repetitive and un-useful data. The proposed protocol Data-Based Energy Efficient Clustered Routing Protocol for Wireless Sensors Networks (DCRP was compared with the famous energy efficient LEACH protocol and also with one of the recent energy efficient routing protocols named Position Responsive Routing Protocol (PRRP. DCRP has been used in monitoring the floods in Tabuk area –Saudi Arabia. It shows comparatively better results.

  10. Pilot study: Assessing the effect of continual position monitoring technology on compliance with patient turning protocols.

    Science.gov (United States)

    Schutt, Suann Cirigliano; Tarver, Christine; Pezzani, Michelle

    2018-01-01

    The study aim was to evaluate if continual patient position monitoring, taking into account self-turns and clinician-assisted turns, would increase the percentage of time a patient's position changed at least every 2 hr. While patient turning has clinical benefits, current models to help staff remember to turn patients, such as "turn clocks" and timers, have not resulted in high compliance with turning protocols. In addition, reminders are based on arbitrary 2-hr windows (such as turning on "even" hours) rather than on individual patient activity, including self-turns. This is a first inpatient, non-randomized, pre-/postintervention study. Data collection occurred from May 2013-February 2014 on a 39-bed medical unit in a community hospital. Baseline patient turning data were recorded by a sensor; however, the patient data were not displayed at the nurses' station to establish compliance with the hospital's turning protocol. Postintervention, patient position information was wirelessly displayed on nurses' station computer monitors in real time. A Student t test was used to compare baseline to postintervention "mean time in compliance." Data from 138 patients ( N  =   7,854 hr of monitoring) were collected. The baseline phase yielded 4,322 hr of position monitoring data and the postintervention phase yielded 3,532 hr of data. Statistically significant improvement was demonstrated in the percentage of time a patient's position changed at least every 2 hr from baseline to postintervention.

  11. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    International Nuclear Information System (INIS)

    Wang, J; Chan, F; Newman, B; Larson, D; Leung, A; Fleischmann, D; Molvin, L; Marsh, D; Zorich, C; Phillips, L

    2014-01-01

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds

  12. Zoonoses action plan Salmonella monitoring programme: an investigation of the sampling protocol.

    Science.gov (United States)

    Snary, E L; Munday, D K; Arnold, M E; Cook, A J C

    2010-03-01

    The Zoonoses Action Plan (ZAP) Salmonella Programme was established by the British Pig Executive to monitor Salmonella prevalence in quality-assured British pigs at slaughter by testing a sample of pigs with a meat juice enzyme-linked immunosorbent assay for antibodies against group B and C(1) Salmonella. Farms were assigned a ZAP level (1 to 3) depending on the monitored prevalence, and ZAP 2 or 3 farms were required to act to reduce the prevalence. The ultimate goal was to reduce the risk of human salmonellosis attributable to British pork. A mathematical model has been developed to describe the ZAP sampling protocol. Results show that the probability of assigning a farm the correct ZAP level was high, except for farms that had a seroprevalence close to the cutoff points between different ZAP levels. Sensitivity analyses identified that the probability of assigning a farm to the correct ZAP level was dependent on the sensitivity and specificity of the test, the number of batches taken to slaughter each quarter, and the number of samples taken per batch. The variability of the predicted seroprevalence was reduced as the number of batches or samples increased and, away from the cutoff points, the probability of being assigned the correct ZAP level increased as the number of batches or samples increased. In summary, the model described here provided invaluable insight into the ZAP sampling protocol. Further work is required to understand the impact of the program for Salmonella infection in British pig farms and therefore on human health.

  13. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  14. Monitoring of high voltage supply using the Controller Area Network protocol

    Energy Technology Data Exchange (ETDEWEB)

    Luz, Igo Amauri dos S.; Farias, Paulo Cesar M.A.; Guedes, Germano P. [Universidade Estadual de Feira de Santana (UEFS), BA (Brazil)

    2011-07-01

    Full text: In recent years, experimental physics has made great progress in the investigation of the phenomenology of neutrinos, with significant contribution from experiments using nuclear reactors as source of particles. In this context, The Neutrinos Angra Project proposes the use of an anti-neutrinos detector with ability to monitor parameters related to the activity of nuclear reactors. One of the tasks defined in the project is the development of a system to control and to monitor the high voltage supply units used by the photomultiplier tubes (PMTs) of the detector. The solution proposed in this work is based on the use of microcontrollers, from Microchip PIC family to adjust the operating point of the high voltage supply units and to acquire the current and output voltage data. Analysis of these data allows the effective control of the gain of the PMTs and to identify anomalous operational conditions. In this work is proposed the study of the Controller Area Network (CAN) protocol and the implementation of a laboratory network to reproduce the typical operations of data acquisition and information transfer between the nodes. The development of this network is divided in two stages. The first part consisted of the setup of a CAN network, using the PIC18F2680 microcontroller, which has the CAN protocol internally implemented. This network serves as a reduced model of the final system, allowing simulation of typical situations of data acquisition and transmission between the nodes and a computer. In the second part of the work, the PIC18F4550 microcontroller was associated with the external CAN controller MCP2515 to develop a CAN/USB converter. This converter provides a new communication channel between network nodes and the computer, in addition to the RS232 interface. (author)

  15. Water quality monitoring protocol for wadeable streams and rivers in the Northern Great Plains Network

    Science.gov (United States)

    Wilson, Marcia H.; Rowe, Barbara L.; Gitzen, Robert A.; Wilson, Stephen K.; Paintner-Green, Kara J.

    2014-01-01

    Preserving the national parks unimpaired for the enjoyment of future generations is a fundamental purpose of the National Park Service (NPS). To address growing concerns regarding the overall physical, chemical, and biological elements and processes of park ecosystems, the NPS implemented science-based management through “Vital Signs” monitoring in 270 national parks (NPS 2007). The Northern Great Plains Network (NGPN) is among the 32 National Park Service Networks participating in this monitoring effort. The NGPN will develop protocols over the next several years to determine the overall health or condition of resources within 13 parks located in Nebraska, North Dakota, South Dakota, and Wyoming.

  16. QoS and energy aware cooperative routing protocol for wildfire monitoring wireless sensor networks.

    Science.gov (United States)

    Maalej, Mohamed; Cherif, Sofiane; Besbes, Hichem

    2013-01-01

    Wireless sensor networks (WSN) are presented as proper solution for wildfire monitoring. However, this application requires a design of WSN taking into account the network lifetime and the shadowing effect generated by the trees in the forest environment. Cooperative communication is a promising solution for WSN which uses, at each hop, the resources of multiple nodes to transmit its data. Thus, by sharing resources between nodes, the transmission quality is enhanced. In this paper, we use the technique of reinforcement learning by opponent modeling, optimizing a cooperative communication protocol based on RSSI and node energy consumption in a competitive context (RSSI/energy-CC), that is, an energy and quality-of-service aware-based cooperative communication routing protocol. Simulation results show that the proposed algorithm performs well in terms of network lifetime, packet delay, and energy consumption.

  17. Delay-tolerant mobile network protocol for rice field monitoring using wireless sensor networks

    Science.gov (United States)

    Guitton, Alexandre; Andres, Frédéric; Cardoso, Jarbas Lopes; Kawtrakul, Asanee; Barbin, Silvio E.

    2015-10-01

    The monitoring of rice fields can improve productivity by helping farmers throughout the rice cultivation cycle, on various issues: when to harvest, when to treat the crops against disease, when to increase the water level, how to share observations and decisions made in a collaborative way, etc. In this paper, we propose an architecture to monitor a rice field by a wireless sensor network. Our architecture is based on static sensor nodes forming a disconnected network, and mobile nodes communicating with the sensor nodes in a delay-tolerant manner. The data collected by the static sensor nodes are transmitted to mobile nodes, which in turn transmit them to a gateway, connected to a database, for further analysis. We focus on the related architecture, as well as on the energy-efficient protocols intended to perform the data collection.

  18. The Distance Standard Deviation

    OpenAIRE

    Edelmann, Dominic; Richards, Donald; Vogel, Daniel

    2017-01-01

    The distance standard deviation, which arises in distance correlation analysis of multivariate data, is studied as a measure of spread. New representations for the distance standard deviation are obtained in terms of Gini's mean difference and in terms of the moments of spacings of order statistics. Inequalities for the distance variance are derived, proving that the distance standard deviation is bounded above by the classical standard deviation and by Gini's mean difference. Further, it is ...

  19. Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes

    The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.

  20. The surface elevation table and marker horizon technique: A protocol for monitoring wetland elevation dynamics

    Science.gov (United States)

    James C. Lynch,; Phillippe Hensel,; Cahoon, Donald R.

    2015-01-01

    The National Park Service, in response to the growing evidence and awareness of the effects of climate change on federal lands, determined that monitoring wetland elevation change is a top priority in North Atlantic Coastal parks (Stevens et al, 2010). As a result, the NPS Northeast Coastal and Barrier Network (NCBN) in collaboration with colleagues from the U.S. Geological Survey (USGS) and The National Oceanic and Atmospheric Administration (NOAA) have developed a protocol for monitoring wetland elevation change and other processes important for determining the viability of wetland communities. Although focused on North Atlantic Coastal parks, this document is applicable to all coastal and inland wetland regions. Wetlands exist within a narrow range of elevation which is influenced by local hydrologic conditions. For coastal wetlands in particular, local hydrologic conditions may be changing as sea levels continue to rise. As sea level rises, coastal wetland systems may respond by building elevation to maintain favorable hydrologic conditions for their survival. This protocol provides the reader with instructions and guidelines on designing a monitoring plan or study to: A) Quantify elevation change in wetlands with the Surface Elevation Table (SET). B) Understand the processes that influence elevation change, including vertical accretion (SET and Marker Horizon methods). C) Survey the wetland surface and SET mark to a common reference datum to allow for comparing sample stations to each other and to local tidal datums. D) Survey the SET mark to monitor its relative stability. This document is divided into two parts; the main body that presents an overview of all aspects of monitoring wetland elevation dynamics, and a collection of Standard Operating Procedures (SOP) that describes in detail how to perform or execute each step of the methodology. Detailed instruction on the installation, data collection, data management and analysis are provided in this report

  1. Renewable Energy Monitoring Protocol. Update 2010. Methodology for the calculation and recording of the amounts of energy produced from renewable sources in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Te Buck, S.; Van Keulen, B.; Bosselaar, L.; Gerlagh, T.; Skelton, T.

    2010-07-15

    This is the fifth, updated edition of the Dutch Renewable Energy Monitoring Protocol. The protocol, compiled on behalf of the Ministry of Economic Affairs, can be considered as a policy document that provides a uniform calculation method for determining the amount of energy produced in the Netherlands in a renewable manner. Because all governments and organisations use the calculation methods described in this protocol, this makes it possible to monitor developments in this field well and consistently. The introduction of this protocol outlines the history and describes its set-up, validity and relationship with other similar documents and agreements. The Dutch Renewable Energy Monitoring Protocol is compiled by NL Agency, and all relevant parties were given the chance to provide input. This has been incorporated as far as is possible. Statistics Netherlands (CBS) uses this protocol to calculate the amount of renewable energy produced in the Netherlands. These data are then used by the Ministry of Economic Affairs to gauge the realisation of policy objectives. In June 2009 the European Directive for energy from renewable sources was published with renewable energy targets for the Netherlands. This directive used a different calculation method - the gross energy end-use method - whilst the Dutch definition is based on the so-called substitution method. NL Agency was asked to add the calculation according to the gross end use method, although this is not clearly defined on a number of points. In describing the method, the unanswered questions become clear, as do, for example, the points the Netherlands should bring up in international discussions.

  2. Flap monitoring after head and neck reconstruction: evaluating an observation protocol.

    Science.gov (United States)

    Devine, J C; Potter, L A; Magennis, P; Brown, J S; Vaughan, E D

    2001-01-01

    This study evaluated the postoperative free-flap monitoring frequency protocol used in a maxillofacial unit for patients receiving free-tissue transfer for reconstruction following orofacial cancer. All free-tissue transfers undertaken in the unit between January 1992 and October 1998 were reviewed retrospectively. Of the 370 patients evaluated, 46 returned to theatre with compromised free flaps. The compromise was purely venous in origin in 37 of these cases, arterial in three and due to a combination of arterial and venous problems in six. Thirty-five of the flaps were successfully salvaged. On average, the clinical manifestation of the problem occurred 25.5 hours postoperatively. However, there was a significant time difference between flaps that were salvaged successfully and those that were not: in the salvaged group the compromise was identified 17.5 hours postsurgery compared with 51 hours for the unsuccessful group. The timing of the return to theatre following the identification of the compromise was a significant factor in the success rate: 71 minutes for those salvaged and 103 minutes for those not salvaged. It is recommended that flaps are monitored hourly for the first 72 postoperative hours and observations recorded on a chart.

  3. Forest bird monitoring protocol for strategic habitat conservation and endangered species management on O'ahu Forest National Wildlife Refuge, Island of O'ahu, Hawai'i

    Science.gov (United States)

    Camp, Richard J.; Gorresen, P. Marcos; Banko, Paul C.

    2011-01-01

    This report describes the results of a pilot forest bird survey and a consequent forest bird monitoring protocol that was developed for the O'ahu Forest National Wildlife Refuge, O'ahu Island, Hawai'i. The pilot survey was conducted to inform aspects of the monitoring protocol and to provide a baseline with which to compare future surveys on the Refuge. The protocol was developed in an adaptive management framework to track bird distribution and abundance and to meet the strategic habitat conservation requirements of the Refuge. Funding for this research was provided through a Science Support Partnership grant sponsored jointly by the U.S. Geological Survey (USGS) and the U.S. Fish and Wildlife Service (USFWS).

  4. Validation of the BPLab® 24-hour blood pressure monitoring system in a pediatric population according to the 1993 British Hypertension Society protocol

    Directory of Open Access Journals (Sweden)

    Ledyaev MY

    2015-02-01

    Full Text Available Mikhail Y Ledyaev, Olga V Stepanova, Anastasia M Ledyaeva Department of Pediatric Disease, Volgograd State Medical University, Volgograd, Russian Federation Background: Automatic 24-hour ambulatory blood pressure (BP monitoring (ABPM is a basic procedure performed in adults with arterial hypertension, but ABPM monitors have become widely used in pediatric practice only recently. The main problem is the lack of common normative data sets for ABPM in children and the small number of appropriate monitors that can be used for analysis of the 24-hour BP profile in this age group. The aim of this study was to validate the BPLab® ABPM monitor according to the 1993 British Hypertension Society (BHS-93 protocol, as well as to work out solutions regarding the feasibility of this device in pediatric practice. Methods: Our study included 30 children of both sexes and aged 5–15 years, ie, “older” children according to the BHS-93 protocol. Before starting the study, we obtained ethical approval from the regional scientific ethics committee. All participants and their parents signed their written consent for participation in the study. The data were simultaneously obtained by three experts, who had completed a noninvasive BP measurement training course. BP values were measured using the Korotkoff auscultatory method (Phase I for systolic BP and Phase V for diastolic BP. Discrepancies in the systolic and diastolic BP measurements (n=180; 90 for each expert were analyzed according to the criteria specified in the BHS-93 protocol. Results: The device was graded “A” for both systolic BP and diastolic BP according to the criteria of the BHS-93 protocol. Conclusion: The BPLab ABPM device may be recommended for extensive pediatric use. Keywords: ambulatory blood pressure monitoring, children, device, validation 

  5. The Impact of Advanced Technologies on Treatment Deviations in Radiation Treatment Delivery

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Light, Kim L.; Hubbs, Jessica L.; Georgas, Debra L.; Jones, Ellen L.; Wright, Melanie C.; Willett, Christopher G.; Yin Fangfang

    2007-01-01

    Purpose: To assess the impact of new technologies on deviation rates in radiation therapy (RT). Methods and Materials: Treatment delivery deviations in RT were prospectively monitored during a time of technology upgrade. In January 2003, our department had three accelerators, none with 'modern' technologies (e.g., without multileaf collimators [MLC]). In 2003 to 2004, we upgraded to five new accelerators, four with MLC, and associated advanced capabilities. The deviation rates among patients treated on 'high-technology' versus 'low-technology' machines (defined as those with vs. without MLC) were compared over time using the two-tailed Fisher's exact test. Results: In 2003, there was no significant difference between the deviation rate in the 'high-technology' versus 'low-technology' groups (0.16% vs. 0.11%, p = 0.45). In 2005 to 2006, the deviation rate for the 'high-technology' groups was lower than the 'low-technology' (0.083% vs. 0.21%, p = 0.009). This difference was caused by a decline in deviations on the 'high-technology' machines over time (p = 0.053), as well as an unexpected trend toward an increase in deviations over time on the 'low-technology' machines (p = 0.15). Conclusions: Advances in RT delivery systems appear to reduce the rate of treatment deviations. Deviation rates on 'high-technology' machines with MLC decline over time, suggesting a learning curve after the introduction of new technologies. Associated with the adoption of 'high-technology' was an unexpected increase in the deviation rate with 'low-technology' approaches, which may reflect an over-reliance on tools inherent to 'high-technology' machines. With the introduction of new technologies, continued diligence is needed to ensure that staff remain proficient with 'low-technology' approaches

  6. Development and validation of a protocol for field validation of passive dosimeters for ethylene oxide excursion limit monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Puskar, M.A.; Szopinski, F.G.; Hecker, L.H. (Corporate Industrial Hygiene Laboratory, Abbott Laboratories, North Chicago, IL (USA))

    1991-04-01

    An exposure and analysis protocol is described for the field validation of passive dosimeters for ethylene oxide (EtO) excursion limit monitoring. The protocol calls for the use of a field exposure chamber with concurrent sampling using Tedlar air-sampling bags. The bags are analyzed immediately after sampling by gas chromatography with flame ionization detection (GC-FID). The chamber design allows all monitors to be exposed for the exact same time in the field. The sampling and analysis procedure not only determines the actual concentration of EtO present during the monitor's exposure but estimates if concentrations of EtO vary from point to point in the monitor array during the exposure. In chamber operation, the accuracy of the standard generator used to calibrate the GC-FID was independently verified in the field by the standard additions method. The sampling bias of the sampling train was determined to be -3.5% in the 2.4 ppm to 14.3 ppm concentration range. To estimate the stability of collected EtO samples in Tedlar bags, the rate of EtO loss in the bags was determined to be 0.011 ppm/hr at 2.57 ppm and 0.066 ppm/hr at 8.07 ppm. Sampling bias of the passive methods by additional EtO exposure of the monitors in the closed chamber after sampling and during purging was determined to be +1.5%. The Tedlar bag sampling method with subsequent GC-FID determination demonstrated a coefficient of variation of 1.8% at 2.43 ppm.

  7. Segmentation Using Symmetry Deviation

    DEFF Research Database (Denmark)

    Hollensen, Christian; Højgaard, L.; Specht, L.

    2011-01-01

    of the CT-scans into a single atlas. Afterwards the standard deviation of anatomical symmetry for the 20 normal patients was evaluated using non-rigid registration and registered onto the atlas to create an atlas for normal anatomical symmetry deviation. The same non-rigid registration was used on the 10...... hypopharyngeal cancer patients to find anatomical symmetry and evaluate it against the standard deviation of the normal patients to locate pathologic volumes. Combining the information with an absolute PET threshold of 3 Standard uptake value (SUV) a volume was automatically delineated. The overlap of automated....... The standard deviation of the anatomical symmetry, seen in figure for one patient along CT and PET, was extracted for normal patients and compared with the deviation from cancer patients giving a new way of determining cancer pathology location. Using the novel method an overlap concordance index...

  8. Application of Allan Deviation to Assessing Uncertainties of Continuous-measurement Instruments, and Optimizing Calibration Schemes

    Science.gov (United States)

    Jacobson, Gloria; Rella, Chris; Farinas, Alejandro

    2014-05-01

    Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits

  9. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    Science.gov (United States)

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and

  10. A monitoring protocol for vegetation change on Irish peatland and heath

    Science.gov (United States)

    O'Connell, J.; Connolly, J.; Holden, N. M.

    2014-09-01

    Amendments to Articles 3.3 and 3.4 of the Kyoto Protocol have meant that detection of vegetation change may now form an interracial part of national soil carbon stocks. In this study multispectral multi-platform satellite data was processed to detect change to the surface vegetation of four peatland sites and one heath in Ireland. Spectral and spatial thresholds were used on difference images between master and slave data in the extraction of temporally invariant targets for multi-platform cross calibration. The Kolmogorov-Smirnov test was used to evaluate any difference in the cumulative probability distributions of the master, slave and calibrated slave data as expressed by the D statistic, with values reduced by an average of 89.7% due to the cross calibration procedure. A change detection model was created which incorporated a spatial threshold of 9 pixels and a standard deviation (SD) spectral threshold. Kappa accuracy values for the five sites ranged from 80 to 97%, showing that 1.5 SD was the optimum spectral threshold for detecting vegetation change. Change detection results showed mean percentage change ranging from 2.11 to 3.28% of total area and cumulative change over the observed time period of between 15.24 and 49.27% of total area.

  11. Large deviations and idempotent probability

    CERN Document Server

    Puhalskii, Anatolii

    2001-01-01

    In the view of many probabilists, author Anatolii Puhalskii''s research results stand among the most significant achievements in the modern theory of large deviations. In fact, his work marked a turning point in the depth of our understanding of the connections between the large deviation principle (LDP) and well-known methods for establishing weak convergence results.Large Deviations and Idempotent Probability expounds upon the recent methodology of building large deviation theory along the lines of weak convergence theory. The author develops an idempotent (or maxitive) probability theory, introduces idempotent analogues of martingales (maxingales), Wiener and Poisson processes, and Ito differential equations, and studies their properties. The large deviation principle for stochastic processes is formulated as a certain type of convergence of stochastic processes to idempotent processes. The author calls this large deviation convergence.The approach to establishing large deviation convergence uses novel com...

  12. Amplification biases: possible differences among deviating gene expressions

    Directory of Open Access Journals (Sweden)

    Piumi Francois

    2008-01-01

    Full Text Available Abstract Background Gene expression profiling has become a tool of choice to study pathological or developmental questions but in most cases the material is scarce and requires sample amplification. Two main procedures have been used: in vitro transcription (IVT and polymerase chain reaction (PCR, the former known as linear and the latter as exponential. Previous reports identified enzymatic pitfalls in PCR and IVT protocols; however the possible differences between the sequences affected by these amplification defaults were only rarely explored. Results Screening a bovine cDNA array dedicated to embryonic stages with embryonic (n = 3 and somatic tissues (n = 2, we proceeded to moderate amplifications starting from 1 μg of total RNA (global PCR or IVT one round. Whatever the tissue, 16% of the probes were involved in deviating gene expressions due to amplification defaults. These distortions were likely due to the molecular features of the affected sequences (position within a gene, GC content, hairpin number but also to the relative abundance of these transcripts within the tissues. These deviating genes mainly encoded housekeeping genes from physiological or cellular processes (70% and constituted 2 subsets which did not overlap (molecular features, signal intensities, gene ID. However, the differential expressions identified between embryonic stages were both reliable (minor intersect with biased expressions and relevant (biologically validated. In addition, the relative expression levels of those genes were biologically similar between amplified and unamplified samples. Conclusion Conversely to the most recent reports which challenged the use of intense amplification procedures on minute amounts of RNA, we chose moderate PCR and IVT amplifications for our gene profiling study. Conclusively, it appeared that systematic biases arose even with moderate amplification procedures, independently of (i the sample used: brain, ovary or embryos, (ii

  13. Wavelength selection method with standard deviation: application to pulse oximetry.

    Science.gov (United States)

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  14. SAMPLE STANDARD DEVIATION(s) CHART UNDER THE ASSUMPTION OF MODERATENESS AND ITS PERFORMANCE ANALYSIS

    OpenAIRE

    Kalpesh S. Tailor

    2017-01-01

    Moderate distribution proposed by Naik V.D and Desai J.M., is a sound alternative of normal distribution, which has mean and mean deviation as pivotal parameters and which has properties similar to normal distribution. Mean deviation (δ) is a very good alternative of standard deviation (σ) as mean deviation is considered to be the most intuitively and rationally defined measure of dispersion. This fact can be very useful in the field of quality control to construct the control limits of the c...

  15. Comparison of IAEA protocols for clinical electron beam dosimetry

    International Nuclear Information System (INIS)

    Novotny, J.; Soukup, M.

    2002-01-01

    In most beam calibration protocols so far used in clinical practice, the method recommended for the determination of absorbed dose to water in high-energy electron beams is based on either an exposure or an air kerma calibration factor of an ionisation chamber in a C0 60 gamma-ray or 2 MV x-ray beam. These protocols are complex and the overall uncertainty in the absorbed dose to water under reference conditions is about 3-4%. The new generation of protocols, namely IAEA TRS 398, are based on absorbed dose-to-water standards in photon beams from Co 60 and accelerator beams. The possible errors in absorbed dose determination in reference conditions in practical clinical dosimetry caused by replacement of TRS 277 and TRS 381 protocols for a new TRS 398 protocol were carefully studied for clinical electron beams in energy range 6-20 MeV. All measurements were performed on Varian CLINAC 2100 C linear accelerator. The electron beam energy ranged from 6 to 20 MeV. Basically three different detectors were used for measurements: PTW Roos plane-parallel ionization chamber, calibrated PTW 30002 Farmer type, ionization, Scanditronix electron diode detector. Measurements of central axis percentage depth doses were made by diode using Wellhoefer WP700 beam scanner in 40 cm x 40 cm x 50 cm water phantom. A reference chamber or semiconductor diode mounted on electron treatment cone was used to correct beam output variations for a chamber or diode measurements during scanning. Absolute dose measurements were carried out with Roos plane-parallel chamber connected to PTW UNIDOS electrometer always for preselected number of monitor units. In a new IAEA dosimetry protocol clinical reference dosimetry for electron beam is performed at depth of d ref = 0.6R 50 - 0.1 [cm] instead of d max as in previous ones. To check the stability of electron beams for energy and to establish d ref and standard deviation for reference depth position, the depth dose curves obtained during the quality

  16. 48 CFR 2001.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2001... Individual deviations. In individual cases, deviations from either the FAR or the NRCAR will be authorized... deviations clearly in the best interest of the Government. Individual deviations must be authorized in...

  17. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  18. 48 CFR 801.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 801... Individual deviations. (a) Authority to authorize individual deviations from the FAR and VAAR is delegated to... nature of the deviation. (d) The DSPE may authorize individual deviations from the FAR and VAAR when an...

  19. Detecting deviating behaviors without models

    NARCIS (Netherlands)

    Lu, X.; Fahland, D.; van den Biggelaar, F.J.H.M.; van der Aalst, W.M.P.; Reichert, M.; Reijers, H.A.

    2016-01-01

    Deviation detection is a set of techniques that identify deviations from normative processes in real process executions. These diagnostics are used to derive recommendations for improving business processes. Existing detection techniques identify deviations either only on the process instance level

  20. Developing a yeast-based assay protocol to monitor total ...

    African Journals Online (AJOL)

    A yeast-based assay protocol developed for detecting oestrogenic activity in activated sludge (AS) supernatant is described. The protocol used Saccharomyces cerevisiae construct RMY/ER-ERE with human oestrogen receptor (ERα) and lacZ reporter genes, and was developed by modifying existing assays for use with AS ...

  1. Estimating maize water stress by standard deviation of canopy temperature in thermal imagery

    Science.gov (United States)

    A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...

  2. 48 CFR 1501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1501.403 Section 1501.403 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY GENERAL GENERAL Deviations 1501.403 Individual deviations. Requests for individual deviations from the FAR and the...

  3. VALIDATION OF THE MECG-DP-NS-01 MONITOR IN OSCILLOMETRY AND AUSCULTATION MODES IN CHILDREN AND ADOLESCENTS, ACCORDING TO ESH-IP2, BHS AND AAMI PROTOCOLS

    Directory of Open Access Journals (Sweden)

    S. I. Fedorova

    2015-01-01

    Full Text Available Background: High blood pressure in childhood and adolescence is associated with a 2 to 3-fold increase of the risk of arterial hypertension. According to the Russian guidelines, only devices that have been tested by international protocols can be used for the main diagnostic method of arterial hypertension in children and adolescents, i.e. ambulatory 24-hour blood pressure monitoring.Aim: To validate the MECG-DP-NS-01 upper arm BP monitor in oscillometry and auscultation modes within the “Soyuz” complex, in children and adolescents aged from 5 to 15 years according to the international protocol of the European Society of Hypertension (ESH from 2010 (ESH-IP2, the protocol of the British Hypertension Society (BHS from 1993 and the standard of the Association for the Advancement of Medical Instrumentation (AAMI.Materials and methods: We recruited 99 children and adolescents (49 male, 50 female aged from 5 to 15 years (33 children, from 5 to 7 years, 33, from 8 to 11 years, 33, from 12 to 15 years. Expert and device blood pressure measurements were performed in each patient according to the protocols.Results: The MECG-DP-NS-01 upper arm blood pressure monitor was validated and its accuracy in blood pressure measurement in children and adolescents according to ESH-IP2, BHS and AAMI protocols confirmed. According to BHS 1993 protocol, its accuracy corresponded to A/A both in the oscillometry and auscultation modes.Conclusion: According to ESH-IP2, BHS and AAMI protocols, MEGC-DP-NS-01 within the “Soyuz” complex could be recommended for 24-hour ambulatory blood pressure monitoring in children and adolescents aged from 5 to 15 years, both in the oscillometry and auscultation modes. According to the Declaration of blood pressure Measuring Device Equivalence signed by the manufacturer for the devices MDP-NS-02s “Voshod” and MEGCDPNS-01, and to the equivalence criteria for blood pressure measuring devices, the results of testing and its

  4. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  5. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  6. 48 CFR 2401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2401... DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Deviations 2401.403 Individual deviations. In individual cases, proposed deviations from the FAR or HUDAR shall be submitted to the Senior Procurement...

  7. Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Kang, Yuan-Yuan; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2013-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor A&D UA-1020 with two different-shaped cuffs for home BP monitoring according to the British Hypertension Society (BHS) Protocol. We recruited individuals for each of the two cuffs (D-ring and cylindrical) until there were 85 eligible participants (255 pairs of comparisons) and their BP could meet the BP distribution requirements specified by the BHS Protocol. For each participant, we sequentially measured the systolic and diastolic BP using a mercury sphygmomanometer (two observers) and the UA-1020 device (one supervisor). For the D-ring cuff, the device achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 87, and 96%, respectively, for systolic BP, and 70, 90, and 99%, respectively, for diastolic BP. The average (±SD) of the device-observer differences was -0.2±7.3 mmHg (P=0.64) and 1.7±5.8 mmHg (P<0.0001) for systolic and diastolic BP, respectively. For the cylindrical cuff, the device also achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 88, and 97%, respectively, for systolic BP and 64, 89, and 98%, respectively, for diastolic BP. The average of the device-observer differences was -0.1±7.0 mmHg (P=0.89) and 2.0±6.3 mmHg (P<0.0001) for systolic and diastolic BP, respectively. The UA-1020 device has passed the requirements of the BHS Protocol with both the D-ring and the cylindrical cuffs, and hence can be recommended for home use in adults.

  8. INDICATIVE MODEL OF DEVIATIONS IN PROJECT

    Directory of Open Access Journals (Sweden)

    Олена Борисівна ДАНЧЕНКО

    2016-02-01

    Full Text Available The article shows the process of constructing the project deviations indicator model. It based on a conceptual model of project deviations integrated management (PDIM. During the project different causes (such as risks, changes, problems, crises, conflicts, stress lead to deviations of integrated project indicators - time, cost, quality, and content. For a more detailed definition of where in the project deviations occur and how they are dangerous for the whole project, it needs to develop an indicative model of project deviations. It allows identifying the most dangerous deviations that require PDIM. As a basis for evaluation of project's success has been taken famous model IPMA Delta. During the evaluation, IPMA Delta estimated project management competence of organization in three modules: I-Module ("Individuals" - a self-assessment personnel, P-module ("Projects" - self-assessment of projects and/or programs, and O-module ("Organization" - used to conduct interviews with selected people during auditing company. In the process of building an indicative model of deviations in the project, the first step is the assessment of project management in the organization by IPMA Delta. In the future, built cognitive map and matrix of system interconnections of the project, which conducted simulations and built a scale of deviations for the selected project. They determined a size and place of deviations. To identify the detailed causes of deviations in the project management has been proposed to use the extended system of indicators, which is based on indicators of project management model Project Excellence. The proposed indicative model of deviations in projects allows to estimate the size of variation and more accurately identify the place of negative deviations in the project and provides the project manager information for operational decision making for the management of deviations in the implementation of the project

  9. 48 CFR 1301.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... DEPARTMENT OF COMMERCE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 1301.403 Individual deviations. The designee authorized to approve individual deviations from the FAR is set forth in CAM 1301.70. ...

  10. 48 CFR 301.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 301... ACQUISITION REGULATION SYSTEM Deviations From the FAR 301.403 Individual deviations. Contracting activities shall prepare requests for individual deviations to either the FAR or HHSAR in accordance with 301.470. ...

  11. 48 CFR 1201.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... FEDERAL ACQUISITION REGULATIONS SYSTEM 70-Deviations From the FAR and TAR 1201.403 Individual deviations... Executive Service (SES) official or that of a Flag Officer, may authorize individual deviations (unless (FAR...

  12. 48 CFR 501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 501... Individual deviations. (a) An individual deviation affects only one contract action. (1) The Head of the Contracting Activity (HCA) must approve an individual deviation to the FAR. The authority to grant an...

  13. 48 CFR 401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 401... AGRICULTURE ACQUISITION REGULATION SYSTEM Deviations From the FAR and AGAR 401.403 Individual deviations. In individual cases, deviations from either the FAR or the AGAR will be authorized only when essential to effect...

  14. 48 CFR 2801.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2801... OF JUSTICE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR and JAR 2801.403 Individual deviations. Individual deviations from the FAR or the JAR shall be approved by the head of the contracting...

  15. Visualizing the Sample Standard Deviation

    Science.gov (United States)

    Sarkar, Jyotirmoy; Rashid, Mamunur

    2017-01-01

    The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…

  16. IoT real time data acquisition using MQTT protocol

    Science.gov (United States)

    Atmoko, R. A.; Riantini, R.; Hasin, M. K.

    2017-05-01

    The Internet of Things (IoT) provides ease to monitor and to gain sensor data through the Internet [1]. The need of high quality data is increasing to the extent that data monitoring and acquisition system in real time is required, such as smart city or telediagnostic in medical areas [2]. Therefore, an appropriate communication protocol is required to resolve these problems. Lately, researchers have developed a lot of communication protocols for IoT, of which each has advantages and disadvantages. This study proposes the utilization of MQTT as a communication protocol, which is one of data communication protocols for IoT. This study used temperature and humidity sensors because the physical parameters are often needed as parameters of environment condition [3]. Data acquisition was done in real-time and stored in MySQL database. This study is also completed by interface web-based and mobile for online monitoring. This result of this study is the enhancement of data quality and reliability using MQTT protocol.

  17. Pilot study: Assessing the effect of continual position monitoring technology on compliance with patient turning protocols

    OpenAIRE

    Schutt, Suann Cirigliano; Tarver, Christine; Pezzani, Michelle

    2017-01-01

    Abstract Aim The study aim was to evaluate if continual patient position monitoring, taking into account self‐turns and clinician‐assisted turns, would increase the percentage of time a patient's position changed at least every 2 hr. Background While patient turning has clinical benefits, current models to help staff remember to turn patients, such as “turn clocks” and timers, have not resulted in high compliance with turning protocols. In addition, reminders are based on arbitrary 2‐hr windo...

  18. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  19. An Adaptive Framework for Selecting Environmental Monitoring Protocols to Support Ocean Renewable Energy Development

    Directory of Open Access Journals (Sweden)

    Emily J. Shumchenia

    2012-01-01

    Full Text Available Offshore renewable energy developments (OREDs are projected to become common in the United States over the next two decades. There are both a need and an opportunity to guide efforts to identify and track impacts to the marine ecosystem resulting from these installations. A monitoring framework and standardized protocols that can be applied to multiple types of ORED would streamline scientific study, management, and permitting at these sites. We propose an adaptive and reactive framework based on indicators of the likely changes to the marine ecosystem due to ORED. We developed decision trees to identify suites of impacts at two scales (demonstration and commercial depending on energy (wind, tidal, and wave, structure (e.g., turbine, and foundation type (e.g., monopile. Impacts were categorized by ecosystem component (benthic habitat and resources, fish and fisheries, avian species, marine mammals, and sea turtles and monitoring objectives were developed for each. We present a case study at a commercial-scale wind farm and develop a monitoring plan for this development that addresses both local and national environmental concerns. In addition, framework has provided a starting point for identifying global research needs and objectives for understanding of the potential effects of ORED on the marine environment.

  20. An adaptive framework for selecting environmental monitoring protocols to support ocean renewable energy development.

    Science.gov (United States)

    Shumchenia, Emily J; Smith, Sarah L; McCann, Jennifer; Carnevale, Michelle; Fugate, Grover; Kenney, Robert D; King, John W; Paton, Peter; Schwartz, Malia; Spaulding, Malcolm; Winiarski, Kristopher J

    2012-01-01

    Offshore renewable energy developments (OREDs) are projected to become common in the United States over the next two decades. There are both a need and an opportunity to guide efforts to identify and track impacts to the marine ecosystem resulting from these installations. A monitoring framework and standardized protocols that can be applied to multiple types of ORED would streamline scientific study, management, and permitting at these sites. We propose an adaptive and reactive framework based on indicators of the likely changes to the marine ecosystem due to ORED. We developed decision trees to identify suites of impacts at two scales (demonstration and commercial) depending on energy (wind, tidal, and wave), structure (e.g., turbine), and foundation type (e.g., monopile). Impacts were categorized by ecosystem component (benthic habitat and resources, fish and fisheries, avian species, marine mammals, and sea turtles) and monitoring objectives were developed for each. We present a case study at a commercial-scale wind farm and develop a monitoring plan for this development that addresses both local and national environmental concerns. In addition, framework has provided a starting point for identifying global research needs and objectives for understanding of the potential effects of ORED on the marine environment.

  1. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  2. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  3. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  4. The reinterpretation of standard deviation concept

    OpenAIRE

    Ye, Xiaoming

    2017-01-01

    Existing mathematical theory interprets the concept of standard deviation as the dispersion degree. Therefore, in measurement theory, both uncertainty concept and precision concept, which are expressed with standard deviation or times standard deviation, are also defined as the dispersion of measurement result, so that the concept logic is tangled. Through comparative analysis of the standard deviation concept and re-interpreting the measurement error evaluation principle, this paper points o...

  5. Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Butner, R. Scott; Reid, Douglas J.; Hoffman, Michael G.; Sullivan, Greg; Blanchard, Jeremy

    2013-07-01

    To evaluate the accuracy of NILM technologies, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

  6. 48 CFR 3401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations. 3401.403 Section 3401.403 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Deviations 3401.403 Individual deviations. An individual...

  7. 48 CFR 1.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...

  8. 48 CFR 2501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2501.403 Section 2501.403 Federal Acquisition Regulations System NATIONAL SCIENCE FOUNDATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 2501.403 Individual deviations. Individual...

  9. Fidelity deviation in quantum teleportation

    OpenAIRE

    Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir

    2018-01-01

    We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel---we here consider the so-called Werner channel. To characterize our resu...

  10. Engagement Strategies for Self-Monitoring Symptoms of Bipolar Disorder With Mobile and Wearable Technology: Protocol for a Randomized Controlled Trial.

    Science.gov (United States)

    Cochran, Amy; Belman-Wells, Livia; McInnis, Melvin

    2018-05-10

    Monitoring signs and symptoms in bipolar disorder (BP) is typically based on regular assessments from patient-clinician interactions. Mobile and wearable technology promises to make monitoring symptoms in BP easier, but little is known about how best to engage individuals with BP in monitoring symptoms. The objective of this study was to provide the rationale and protocol for a randomized controlled trial that investigates engagement strategies for monitoring symptoms of BP, including the strategies of using activity trackers compared with self-reports and reviewing recorded symptoms weekly with an interviewer. A total of 50 individuals with BP will be recruited from the Prechter Longitudinal Study of Bipolar Disorder at the University of Michigan to participate in a 6-week study. Participants will monitor their symptoms through an activity tracker (Fitbit Alta HR) and a mobile phone app designed for this study. In addition to monitoring symptoms, participants have a 50-50 chance of being assigned to an arm that reviews self-reports and activity information weekly. Statistical tests will be performed to test hypotheses that participants adhere to activity tracking significantly more than self-reporting, prefer activity tracking significantly more than self-reporting, and better adhere to both activity tracking and self-reporting when reviewing collected information weekly. Recruitment commenced in November 2017. The first group of participants began the study in January 2018. This study aims to establish strategies to engage individuals with BP in monitoring their symptoms with mobile and wearable technology. Better engagement strategies are expected to aid current efforts in bipolar research and clinical care, from the development of new mobile phone apps to providing the right intervention to the right individual at the right moment. ClinicalTrials.gov NCT03358238; https://clinicaltrials.gov/ct2/show/NCT03358238 (Archived by WebCite at http

  11. 48 CFR 601.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 601.403 Section 601.403 Federal Acquisition Regulations System DEPARTMENT OF STATE GENERAL DEPARTMENT OF STATE ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 601.403 Individual deviations. The...

  12. 48 CFR 201.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Individual deviations. 201.403 Section 201.403 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Individual deviations. (1) Individual deviations, except those described in 201.402(1) and paragraph (2) of...

  13. 48 CFR 3001.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations... from the FAR and HSAR 3001.403 Individual deviations. Unless precluded by law, executive order, or other regulation, the HCA is authorized to approve individual deviation (except with respect to (FAR) 48...

  14. 48 CFR 1901.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1901.403 Section 1901.403 Federal Acquisition Regulations System BROADCASTING BOARD OF GOVERNORS GENERAL... Individual deviations. Deviations from the IAAR or the FAR in individual cases shall be authorized by the...

  15. RCRA groundwater data analysis protocol for the Hanford Site, Washington

    International Nuclear Information System (INIS)

    Chou, C.J.; Jackson, R.L.

    1992-04-01

    The Resource Conservation and Recovery Act of 1976 (RCRA) groundwater monitoring program currently involves site-specific monitoring of 20 facilities on the Hanford Site in southeastern Washington. The RCRA groundwater monitoring program has collected abundant data on groundwater quality. These data are used to assess the impact of a facility on groundwater quality or whether remediation efforts under RCRA corrective action programs are effective. Both evaluations rely on statistical analysis of groundwater monitoring data. The need for information on groundwater quality by regulators and environmental managers makes statistical analysis of monitoring data an important part of RCRA groundwater monitoring programs. The complexity of groundwater monitoring programs and variabilities (spatial, temporal, and analytical) exhibited in groundwater quality variables indicate the need for a data analysis protocol to guide statistical analysis. A data analysis protocol was developed from the perspective of addressing regulatory requirements, data quality, and management information needs. This data analysis protocol contains four elements: data handling methods; graphical evaluation techniques; statistical tests for trend, central tendency, and excursion analysis; and reporting procedures for presenting results to users

  16. Deviating From the Benchmarks

    DEFF Research Database (Denmark)

    Rocha, Vera; Van Praag, Mirjam; Carneiro, Anabela

    This paper studies three related questions: To what extent otherwise similar startups employ different quantities and qualities of human capital at the moment of entry? How persistent are initial human capital choices over time? And how does deviating from human capital benchmarks influence firm......, founders human capital, and the ownership structure of startups (solo entrepreneurs versus entrepreneurial teams). We then study the survival implications of exogenous deviations from these benchmarks, based on spline models for survival data. Our results indicate that (especially negative) deviations from...... the benchmark can be substantial, are persistent over time, and hinder the survival of firms. The implications may, however, vary according to the sector and the ownership structure at entry. Given the stickiness of initial choices, wrong human capital decisions at entry turn out to be a close to irreversible...

  17. Computer generation of random deviates

    International Nuclear Information System (INIS)

    Cormack, John

    1991-01-01

    The need for random deviates arises in many scientific applications. In medical physics, Monte Carlo simulations have been used in radiology, radiation therapy and nuclear medicine. Specific instances include the modelling of x-ray scattering processes and the addition of random noise to images or curves in order to assess the effects of various processing procedures. Reliable sources of random deviates with statistical properties indistinguishable from true random deviates are a fundamental necessity for such tasks. This paper provides a review of computer algorithms which can be used to generate uniform random deviates and other distributions of interest to medical physicists, along with a few caveats relating to various problems and pitfalls which can occur. Source code listings for the generators discussed (in FORTRAN, Turbo-PASCAL and Data General ASSEMBLER) are available on request from the authors. 27 refs., 3 tabs., 5 figs

  18. The University of Western Ontario Pediatric Audiological Monitoring Protocol (UWO PedAMP)

    Science.gov (United States)

    Moodie, Sheila T.; Malandrino, April C.; Richert, Frances M.; Clench, Debbie A.; Scollie, Susan D.

    2011-01-01

    This study proposed and evaluated a guideline for outcome evaluation for infants and children with hearing loss who wear hearing aids. The University of Western Ontario Pediatric Audiological Monitoring Protocol (UWO PedAMP) was developed following a critical review of pediatric outcome evaluation tools and was systematically examined by the Network of Pediatric Audiologists of Canada. It consists of tools to gather clinical process outcomes as well as functional caregiver reports. The UWO PedAMP was administered to a clinical population of infants and children with hearing aids. Sixty-eight children were administered the functional outcome evaluation tools (i.e., caregiver reports) a total of 133 times. Clinical process outcomes of hearing aid verification (e.g., real-ear-to-coupler difference) revealed typical aided audibility (e.g., Speech Intelligibility Index). Results for the LittlEARS® questionnaire revealed that typically developing children with hearing loss who wear hearing aids are meeting auditory development milestones. Children with mild to moderate comorbidities displayed typical auditory development during the 1st year of life after which development began to decline. Children with complex factors related to hearing aid use had lower scores on the LittlEARS, but auditory development was in parallel to norms. Parents’ Evaluation of Aural/Oral Performance (PEACH) results indicated no age effect on scoring for children above 2 years of age; however, the effect of degree of hearing loss was significant. This work provides clinicians with a systematic, evidence-based outcome evaluation protocol to implement as part of a complete pediatric hearing aid fitting. PMID:22194316

  19. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.

    Science.gov (United States)

    Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-01

    An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Surgical Success Rates for Horizontal Concomitant Deviations According to the Type and Degree of Deviation

    Directory of Open Access Journals (Sweden)

    İhsan Çaça

    2004-01-01

    Full Text Available We evaluated the correlation with success rates and deviation type and degree inhorizontal concomitant deviations. 104 horizontal concomitan strabismus cases whowere operated in our clinic between January 1994 – December 2000 were included in thestudy. 56 cases undergone recession-resection procedure in the same eye 19 cases twomuscle recession and one muscle resection, 20 cases two muscle recession, 9 cases onlyone muscle recession. 10 ± prism diopter deviation in postoperative sixth monthexamination was accepted as surgical success.Surgical success rate was 90% and 89.3% in the cases with deviation angle of 15-30and 31-50 prism diopter respectively. Success rate was 78.9% if the angle was more than50 prism diopter. According to strabismus type when surgical success rate examined; inalternan esotropia 88.33%, in alternan exotropia 84.6%, in monocular esotropia 88%and in monocular exotropia 83.3% success was fixed. Statistically significant differencewas not found between strabismus type and surgical success rate. The binocular visiongaining rate was found as 51.8% after the treatment of cases.In strabismus surgery, preoperative deviation angle was found to be an effectivefactor on the success rate.

  1. 14 CFR 21.609 - Approval for deviation.

    Science.gov (United States)

    2010-01-01

    ... deviation. (a) Each manufacturer who requests approval to deviate from any performance standard of a TSO shall show that the standards from which a deviation is requested are compensated for by factors or... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Approval for deviation. 21.609 Section 21...

  2. Direct data access protocols benchmarking on DPM

    Science.gov (United States)

    Furano, Fabrizio; Devresse, Adrien; Keeble, Oliver; Mancinelli, Valentina

    2015-12-01

    The Disk Pool Manager is an example of a multi-protocol, multi-VO system for data access on the Grid that went though a considerable technical evolution in the last years. Among other features, its architecture offers the opportunity of testing its different data access frontends under exactly the same conditions, including hardware and backend software. This characteristic inspired the idea of collecting monitoring information from various testbeds in order to benchmark the behaviour of the HTTP and Xrootd protocols for the use case of data analysis, batch or interactive. A source of information is the set of continuous tests that are run towards the worldwide endpoints belonging to the DPM Collaboration, which accumulated relevant statistics in its first year of activity. On top of that, the DPM releases are based on multiple levels of automated testing that include performance benchmarks of various kinds, executed regularly every day. At the same time, the recent releases of DPM can report monitoring information about any data access protocol to the same monitoring infrastructure that is used to monitor the Xrootd deployments. Our goal is to evaluate under which circumstances the HTTP-based protocols can be good enough for batch or interactive data access. In this contribution we show and discuss the results that our test systems have collected under the circumstances that include ROOT analyses using TTreeCache and stress tests on the metadata performance.

  3. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    Science.gov (United States)

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  4. Development of a Land Use Mapping and Monitoring Protocol for the High Plains Region: A Multitemporal Remote Sensing Application

    Science.gov (United States)

    Price, Kevin P.; Nellis, M. Duane

    1996-01-01

    The purpose of this project was to develop a practical protocol that employs multitemporal remotely sensed imagery, integrated with environmental parameters to model and monitor agricultural and natural resources in the High Plains Region of the United States. The value of this project would be extended throughout the region via workshops targeted at carefully selected audiences and designed to transfer remote sensing technology and the methods and applications developed. Implementation of such a protocol using remotely sensed satellite imagery is critical for addressing many issues of regional importance, including: (1) Prediction of rural land use/land cover (LULC) categories within a region; (2) Use of rural LULC maps for successive years to monitor change; (3) Crop types derived from LULC maps as important inputs to water consumption models; (4) Early prediction of crop yields; (5) Multi-date maps of crop types to monitor patterns related to crop change; (6) Knowledge of crop types to monitor condition and improve prediction of crop yield; (7) More precise models of crop types and conditions to improve agricultural economic forecasts; (8;) Prediction of biomass for estimating vegetation production, soil protection from erosion forces, nonpoint source pollution, wildlife habitat quality and other related factors; (9) Crop type and condition information to more accurately predict production of biogeochemicals such as CO2, CH4, and other greenhouse gases that are inputs to global climate models; (10) Provide information regarding limiting factors (i.e., economic constraints of pumping, fertilizing, etc.) used in conjunction with other factors, such as changes in climate for predicting changes in rural LULC; (11) Accurate prediction of rural LULC used to assess the effectiveness of government programs such as the U.S. Soil Conservation Service (SCS) Conservation Reserve Program; and (12) Prediction of water demand based on rural LULC that can be related to rates of

  5. Entanglement transitions induced by large deviations

    Science.gov (United States)

    Bhosale, Udaysinh T.

    2017-12-01

    The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B , is computed analytically using a Coulomb gas method. It is shown that this probability, for large N , goes as exp[-β N2Φ (ζ ) ] , where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ (ζ ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A , using the properties of the density matrix's partial transpose ρ12Γ. The density of states of ρ12Γ is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ . Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.

  6. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  7. Energy conservation in the Netherlands 1995-2006. Update on the basis of the Protocol Monitoring Energy Conservation; Energiebesparing in Nederland 1995-2006. Update op basis van het Protocol Monitoring Energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M.; Gerdes, J. [ECN Beleidsstudies, Petten (Netherlands); Vreuls, H.H.J. [SenterNovem, Utrecht (Netherlands); Verdonk, M. [Planbureau voor de Leefomgeving PBL, Bilthoven (Netherlands); Pouwels, H. [Centraal bureau voor de Statistiek CBS, Voorburg/Heerlen (Netherlands)

    2008-07-15

    Results are presented of realized energy savings in the Netherlands for the period 1995-2006 for the sectors households, industry, agriculture, services, transport, refineries and electricity, and for the national level. The figures on energy savings are based on the 'Protocol Monitoring Energy Savings', a common methodology and database to calculate the amount of energy savings. A description of the methodology used can be found elsewhere. Results are presented for savings on final energy use, conversion in end-use sectors (co-generation) and conversion in the energy sector. National savings for the period 1995-2006 equal 0.9% per year on average, with a decreasing tendency in recent years. For end-use sectors the highest figure is found for agriculture (2.1%) and the lowest figure for transport (0.4%). An uncertainty analysis reveals that the margin for the national savings figure is {+-} 0.3 percent-point. [Dutch] In dit rapport worden de energiebesparingcijfers gepresenteerd voor de periode 1995-2006, berekend volgens het Protocol Monitoring Energiebesparing (PME). De besparing wordt berekend voor de verbruiksectoren industrie, huishoudens, transport, land- en tuinbouw, diensten en raffinaderijen, de elektriciteitscentrales en het nationale niveau. De nationale besparing in de periode 1995-2006 bedroeg gemiddeld ruim 0,9% per jaar. Als er vanaf 1995 niet zou zijn bespaard, dan zou het energiegebruik in 2006 ongeveer 11% hoger zijn geweest. Per sector varieert de besparing tussen 0,4% voor Transport en 2,1% voor de Land- en tuinbouw (inclusief 0,4% door warmte/kracht). In de figuur wordt het verloop van de gemiddelde jaarlijkse besparing vanaf 1995 gegeven. De nationale besparing blijkt na 2000 geleidelijk af te nemen. Hetzelfde geldt voor de Industrie en, met fluctuaties, Huishoudens en Transport. De besparing door warmte/kracht-productie bij verbruikers is ook afgenomen na 2000. Hetzelfde geldt voor besparing bij centrales, hoewel hier in 2006 een

  8. 22 CFR 226.4 - Deviations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Deviations. 226.4 Section 226.4 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS General § 226.4 Deviations. The Office of Management and Budget (OMB) may grant exceptions for...

  9. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, J.W.E. van

    1998-07-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  10. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van

    1998-01-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  11. Protocol of specific health monitoring: ionizing radiation, 11 years later; Protocolo de vigilancia sanitaria especifica: radiaciones ionizantes, 11 anos despues

    Energy Technology Data Exchange (ETDEWEB)

    Castillejo Puertas, F. M.

    2016-08-01

    Since the approval on November 11{sup t}h 2003 of the Protocol of Specific Health Monitoring for Workers Exposed to Ionizing Radiation a study has been carried out to discover its effectiveness. These areas were examined: the daily practice od accupational medicine and, in particular, its specific task in the application of the different clinical/labour criteria for workers exposed to ionizing radiation or at risk of radioactive contamination; the degree of its uses as well as the updates and improvements. For that purpose, a descriptive bibliographic revision has been used for the last 11 years. The results revealed the lack of updates of the Protocol as well as the few usable objective criteria, when the clinical/labour aptitudes are reflected upon. (Author)

  12. The Standard Deviation of Launch Vehicle Environments

    Science.gov (United States)

    Yunis, Isam

    2005-01-01

    Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.

  13. Deviations from thermal equilibrium in plasmas

    International Nuclear Information System (INIS)

    Burm, K.T.A.L.

    2004-01-01

    A plasma system in local thermal equilibrium can usually be described with only two parameters. To describe deviations from equilibrium two extra parameters are needed. However, it will be shown that deviations from temperature equilibrium and deviations from Saha equilibrium depend on one another. As a result, non-equilibrium plasmas can be described with three parameters. This reduction in parameter space will ease the plasma describing effort enormously

  14. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    Science.gov (United States)

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  15. e-SCP-ECG+ Protocol: An Expansion on SCP-ECG Protocol for Health Telemonitoring—Pilot Implementation

    Directory of Open Access Journals (Sweden)

    George J. Mandellos

    2010-01-01

    Full Text Available Standard Communication Protocol for Computer-assisted Electrocardiography (SCP-ECG provides standardized communication among different ECG devices and medical information systems. This paper extends the use of this protocol in order to be included in health monitoring systems. It introduces new sections into SCP-ECG structure for transferring data for positioning, allergies, and five additional biosignals: noninvasive blood pressure (NiBP, body temperature (Temp, Carbon dioxide (CO2, blood oxygen saturation (SPO2, and pulse rate. It also introduces new tags in existing sections for transferring comprehensive demographic data. The proposed enhanced version is referred to as e-SCP-ECG+ protocol. This paper also considers the pilot implementation of the new protocol as a software component in a Health Telemonitoring System.

  16. Implementation Of The Precision Agriculture Using LEACH Protocol Of Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Than Htike Aung

    2015-08-01

    Full Text Available The evolution of wireless sensor network technology leads to develop advanced systems for real-time monitoring. Wireless sensor network WSN is a major technology that drives the development of precision agriculture.By forming wireless sensor networkagricultural practicescan be made good monitoring systems.Various agricultural parameters like soil moisture temperature and humidity are monitored by monitoring units.The paper explains about how to utilize thesensors in agricultural practices and explains about routing protocols of wireless sensor network. In this paper agricultural parameter of temperature will monitor with the use of LEACH protocol.

  17. DreamTel; Diabetes risk evaluation and management tele-monitoring study protocol.

    Science.gov (United States)

    Tobe, Sheldon W; Wentworth, Joan; Ironstand, Laurie; Hartman, Susan; Hoppe, Jackie; Whiting, Judi; Kennedy, Janice; McAllister, Colin; Kiss, Alex; Perkins, Nancy; Vincent, Lloyd; Pylypchuk, George; Lewanczuk, Richard Z

    2009-05-09

    The rising prevalence of type 2 diabetes underlines the importance of secondary strategies for the prevention of target organ damage. While access to diabetes education centers and diabetes intensification management has been shown to improve blood glucose control, these services are not available to all that require them, particularly in rural and northern areas. The provision of these services through the Home Care team is an advance that can overcome these barriers. Transfer of blood glucose data electronically from the home to the health care provider may improve diabetes management. The study population will consist of patients with type 2 diabetes with uncontrolled A1c levels living on reserve in the Battlefords region of Saskatchewan, Canada. This pilot study will take place over three phases. In the first phase over three months the impact of the introduction of the Bluetooth enabled glucose monitor will be assessed. In the second phase over three months, the development of guidelines based treatment algorithms for diabetes intensification will be completed. In the third phase lasting 18 months, study subjects will have diabetes intensification according to the algorithms developed. The first phase will determine if the use of the Bluetooth enabled blood glucose devices which can transmit results electronically will lead to changes in A1c levels. It will also determine the feasibility of recruiting subjects to use this technology. The rest of the Diabetes Risk Evaluation and Management Tele-monitoring (DreamTel) study will determine if the delivery of a diabetes intensification management program by the Home Care team supported by the Bluetooth enabled glucose meters leads to improvements in diabetes management. Protocol NCT00325624.

  18. SPP: A data base processor data communications protocol

    Science.gov (United States)

    Fishwick, P. A.

    1983-01-01

    The design and implementation of a data communications protocol for the Intel Data Base Processor (DBP) is defined. The protocol is termed SPP (Service Port Protocol) since it enables data transfer between the host computer and the DBP service port. The protocol implementation is extensible in that it is explicitly layered and the protocol functionality is hierarchically organized. Extensive trace and performance capabilities have been supplied with the protocol software to permit optional efficient monitoring of the data transfer between the host and the Intel data base processor. Machine independence was considered to be an important attribute during the design and implementation of SPP. The protocol source is fully commented and is included in Appendix A of this report.

  19. Deviating measurements in radiation protection. Legal assessment of deviations in radiation protection measurements

    International Nuclear Information System (INIS)

    Hoegl, A.

    1996-01-01

    This study investigates how, from a legal point of view, deviations in radiation protection measurements should be treated in comparisons between measured results and limits stipulated by nuclear legislation or goods transport regulations. A case-by-case distinction is proposed which is based on the legal concequences of the respective measurement. Commentaries on nuclear law contain no references to the legal assessment of deviating measurements in radiation protection. The examples quoted in legal commentaries on civil and criminal proceedings of the way in which errors made in measurements for speed control and determinations of the alcohol content in the blood are to be taken into account, and a commentary on ozone legislation, are examined for analogies with radiation protection measurements. Leading cases in the nuclear field are evaluated in the light of the requirements applying in case of deviations in measurements. The final section summarizes the most important findings and conclusions. (orig.) [de

  20. Evaluation of a realtime, remote monitoring telemedicine system using the Bluetooth protocol and a mobile phone network.

    Science.gov (United States)

    Jasemian, Yousef; Arendt-Nielsen, Lars

    2005-01-01

    A generic, realtime wireless telemedicine system has been developed that uses the Bluetooth protocol and the general packet radio service for mobile phones. The system was tested on 10 healthy volunteers, by continuous monitoring of their electrocardiograms (ECGs). Under realistic conditions, the system had 96.5% uptime, a data throughput of 3.3 kbit/s, a mean packet error rate of 8.5x10(-3) packet/s and a mean packet loss rate of 8.2x10(-3) packet/s. During 24 h testing, the total average downtime was 66 min and 90% of the periods of downtime were of only 1-3 min duration. Less than 10% of the ECGs were of unacceptable quality. Thus, the generic telemedicine system showed high reliability and performance, and the design may provide a foundation for realtime monitoring in clinical practice, for example in cardiology.

  1. The FOBIMO (FOraminiferal BIo-MOnitoring) initiative—Towards a standardised protocol for soft-bottom benthic foraminiferal monitoring studies

    Science.gov (United States)

    Schoenfeld, Joachim; Alve, Elisabeth; Geslin, Emmanuelle; Jorissen, Frans; Korsun, Sergei; Spezzaferri, Silva; Abramovich, Sigal; Almogi-Labin, Ahuva; Armynot du Chatelet, Eric; Barras, Christine; Bergamin, Luisa; Bicchi, Erica; Bouchet, Vincent; Cearreta, Alejandro; Di Bella, Letizia; Dijkstra, Noortje; Trevisan Disaro, Sibelle; Ferraro, Luciana; Frontalini, Fabrizio; Gennari, Giordana; Golikova, Elena; Haynert, Kristin; Hess, Silvia; Husum, Katrine; Martins, Virginia; McGann, Mary; Oron, Shai; Romano, Elena; Mello Sousa, Silvia; Tsujimoto, Akira

    2012-01-01

    63-μm screen, and the living benthic foraminiferal fauna of the > 125 μm fraction is to be analysed. Splits are to be picked and counted entirely, and all counted foraminifera from at least one replicate per station have to be stored in micropalaeontological slides. Census data, supplementary laboratory data and microslides have to be archived. Advisory recommendations are to sample in autumn, to have a sample size of 50 cm2 or a tube of 8 cm inner diameter, to use > 70% ethanol as a preservative, rose Bengal at a concentration of 2 grams per litre for staining, and a staining time of at least 14 days. The split size should be defined by a target value of 300 specimens, heavy liquid separation should be avoided, and the 63–125 μm fraction or deeper sediment levels may be considered in some environments. We are convinced that the application of this protocol by a large number of scientists is a necessary first step to a general acceptance of benthic foraminifera as a reliable tool in bio-monitoring studies.

  2. Supportive Mental Health Self-Monitoring among Smartphone Users with Psychological Distress: Protocol for a Fully Mobile Randomized Controlled Trial

    OpenAIRE

    Till Beiwinkel; Stefan Hey; Olaf Bock; Wulf Rössler; Wulf Rössler; Wulf Rössler

    2017-01-01

    Mobile health (mHealth) could be widely used in the population to improve access to psychological treatment. In this paper, we describe the development of a mHealth intervention on the basis of supportive self-monitoring and describe the protocol for a randomized controlled trial to evaluate its effectiveness among smartphone users with psychological distress. Based on power analysis, a representative quota sample of N = 186 smartphone users will be recruited, with an over-sampling of persons...

  3. Real-Time Pretreatment Review Limits Unacceptable Deviations on a Cooperative Group Radiation Therapy Technique Trial: Quality Assurance Results of RTOG 0933

    International Nuclear Information System (INIS)

    Gondi, Vinai; Cui, Yunfeng; Mehta, Minesh P.; Manfredi, Denise; Xiao, Ying; Galvin, James M.; Rowley, Howard; Tome, Wolfgang A.

    2015-01-01

    Purpose: RTOG 0933 was a phase II trial of hippocampal avoidance during whole brain radiation therapy for patients with brain metastases. The results demonstrated improvement in short-term memory decline, as compared with historical control individuals, and preservation of quality of life. Integral to the conduct of this trial were quality assurance processes inclusive of pre-enrollment credentialing and pretreatment centralized review of enrolled patients. Methods and Materials: Before enrolling patients, all treating physicians and sites were required to successfully complete a “dry-run” credentialing test. The treating physicians were credentialed based on accuracy of magnetic resonance imaging–computed tomography image fusion and hippocampal and normal tissue contouring, and the sites were credentialed based on protocol-specified dosimetric criteria. Using the same criteria, pretreatment centralized review of enrolled patients was conducted. Physicians enrolling 3 consecutive patients without unacceptable deviations were permitted to enroll further patients without pretreatment review, although their cases were reviewed after treatment. Results: In all, 113 physicians and 84 sites were credentialed. Eight physicians (6.8%) failed hippocampal contouring on the first attempt; 3 were approved on the second attempt. Eight sites (9.5%) failed intensity modulated radiation therapy planning on the first attempt; all were approved on the second attempt. One hundred thirteen patients were enrolled in RTOG 0933; 100 were analyzable. Eighty-seven cases were reviewed before treatment; 5 (5.7%) violated the eligibility criteria, and 21 (24%) had unacceptable deviations. With feedback, 18 cases were approved on the second attempt and 2 cases on the third attempt. One patient was treated off protocol. Twenty-two cases were reviewed after treatment; 1 (4.5%) violated the eligibility criteria, and 5 (23%) had unacceptable deviations. Conclusions: Although >95% of the

  4. Real-Time Pretreatment Review Limits Unacceptable Deviations on a Cooperative Group Radiation Therapy Technique Trial: Quality Assurance Results of RTOG 0933

    Energy Technology Data Exchange (ETDEWEB)

    Gondi, Vinai, E-mail: vgondi@chicagocancer.org [Cadence Brain Tumor Center and CDH Proton Center, Warrenville, Illinois (United States); University of Wisconsin School of Medicine & Public Health, Madison, Wisconsin (United States); Cui, Yunfeng [Duke University School of Medicine, Durham, North Carolina (United States); Mehta, Minesh P. [University of Maryland School of Medicine, Baltimore, Maryland (United States); Manfredi, Denise [Radiation Therapy Oncology Group—RTQA, Philadelphia, Pennsylvania (United States); Xiao, Ying; Galvin, James M. [Thomas Jefferson University Hospital, Philadelphia, Pennsylvania (United States); Rowley, Howard [University of Wisconsin School of Medicine & Public Health, Madison, Wisconsin (United States); Tome, Wolfgang A. [Montefiore Medical Center and Institute for Onco-Physics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States)

    2015-03-01

    Purpose: RTOG 0933 was a phase II trial of hippocampal avoidance during whole brain radiation therapy for patients with brain metastases. The results demonstrated improvement in short-term memory decline, as compared with historical control individuals, and preservation of quality of life. Integral to the conduct of this trial were quality assurance processes inclusive of pre-enrollment credentialing and pretreatment centralized review of enrolled patients. Methods and Materials: Before enrolling patients, all treating physicians and sites were required to successfully complete a “dry-run” credentialing test. The treating physicians were credentialed based on accuracy of magnetic resonance imaging–computed tomography image fusion and hippocampal and normal tissue contouring, and the sites were credentialed based on protocol-specified dosimetric criteria. Using the same criteria, pretreatment centralized review of enrolled patients was conducted. Physicians enrolling 3 consecutive patients without unacceptable deviations were permitted to enroll further patients without pretreatment review, although their cases were reviewed after treatment. Results: In all, 113 physicians and 84 sites were credentialed. Eight physicians (6.8%) failed hippocampal contouring on the first attempt; 3 were approved on the second attempt. Eight sites (9.5%) failed intensity modulated radiation therapy planning on the first attempt; all were approved on the second attempt. One hundred thirteen patients were enrolled in RTOG 0933; 100 were analyzable. Eighty-seven cases were reviewed before treatment; 5 (5.7%) violated the eligibility criteria, and 21 (24%) had unacceptable deviations. With feedback, 18 cases were approved on the second attempt and 2 cases on the third attempt. One patient was treated off protocol. Twenty-two cases were reviewed after treatment; 1 (4.5%) violated the eligibility criteria, and 5 (23%) had unacceptable deviations. Conclusions: Although >95% of the

  5. 9 CFR 318.308 - Deviations in processing.

    Science.gov (United States)

    2010-01-01

    ...) Deviations in processing (or process deviations) must be handled according to: (1)(i) A HACCP plan for canned...) of this section. (c) [Reserved] (d) Procedures for handling process deviations where the HACCP plan... accordance with the following procedures: (a) Emergency stops. (1) When retort jams or breakdowns occur...

  6. Validation of the Pangao PG-800B26 upper arm blood pressure monitor in the general population according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Chen, Liang; Li, Jiyu; Wen, Jing; Guo, Changfeng; Zhang, Jingying; Yu, Zhen

    2018-02-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Pangao PG-800B26 for home blood pressure monitoring according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. Systolic and diastolic blood pressures were measured sequentially in 33 and 85 adults, respectively, on the basis of the ESH-IP and BHS protocols using a mercury sphygmomanometer (two observers) and the device (one supervisor). The procedures and analysis methods of the protocols were followed precisely. The device fulfilled the criteria of the ESH-IP, with device-observer differences of 1.01±5.16 and -0.58±4.17 mmHg for systolic and diastolic blood pressure, respectively. Furthermore, the A/A grade of the BHS protocol was also achieved for overall grading and for the three pressure levels, with average differences of 0.85±6.35 and -0.15±5.65 mmHg for systolic and diastolic blood pressure, respectively, which also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800B26 fulfilled the criteria of the ESH-IP 2010 and achieved the A/A grade of the BHS protocol, and hence can be recommended for home use in adults.

  7. Costing 'healthy' food baskets in Australia - a systematic review of food price and affordability monitoring tools, protocols and methods.

    Science.gov (United States)

    Lewis, Meron; Lee, Amanda

    2016-11-01

    To undertake a systematic review to determine similarities and differences in metrics and results between recently and/or currently used tools, protocols and methods for monitoring Australian healthy food prices and affordability. Electronic databases of peer-reviewed literature and online grey literature were systematically searched using the PRISMA approach for articles and reports relating to healthy food and diet price assessment tools, protocols, methods and results that utilised retail pricing. National, state, regional and local areas of Australia from 1995 to 2015. Assessment tools, protocols and methods to measure the price of 'healthy' foods and diets. The search identified fifty-nine discrete surveys of 'healthy' food pricing incorporating six major food pricing tools (those used in multiple areas and time periods) and five minor food pricing tools (those used in a single survey area or time period). Analysis demonstrated methodological differences regarding: included foods; reference households; use of availability and/or quality measures; household income sources; store sampling methods; data collection protocols; analysis methods; and results. 'Healthy' food price assessment methods used in Australia lack comparability across all metrics and most do not fully align with a 'healthy' diet as recommended by the current Australian Dietary Guidelines. None have been applied nationally. Assessment of the price, price differential and affordability of healthy (recommended) and current (unhealthy) diets would provide more robust and meaningful data to inform health and fiscal policy in Australia. The INFORMAS 'optimal' approach provides a potential framework for development of these methods.

  8. Lightweight UDP Pervasive Protocol in Smart Home Environment Based on Labview

    Science.gov (United States)

    Kurniawan, Wijaya; Hannats Hanafi Ichsan, Mochammad; Rizqika Akbar, Sabriansyah; Arwani, Issa

    2017-04-01

    TCP (Transmission Control Protocol) technology in a reliable environment was not a problem, but not in an environment where the entire Smart Home network connected locally. Currently employing pervasive protocols using TCP technology, when data transmission is sent, it would be slower because they have to perform handshaking process in advance and could not broadcast the data. On smart home environment, it does not need large size and complex data transmission between monitoring site and monitoring center required in Smart home strain monitoring system. UDP (User Datagram Protocol) technology is quick and simple on data transmission process. UDP can broadcast messages because the UDP did not require handshaking and with more efficient memory usage. LabVIEW is a programming language software for processing and visualization of data in the field of data acquisition. This paper proposes to examine Pervasive UDP protocol implementations in smart home environment based on LabVIEW. UDP coded in LabVIEW and experiments were performed on a PC and can work properly.

  9. DreamTel; Diabetes risk evaluation and management tele-monitoring study protocol

    Directory of Open Access Journals (Sweden)

    Kiss Alex

    2009-05-01

    Full Text Available Abstract Background The rising prevalence of type 2 diabetes underlines the importance of secondary strategies for the prevention of target organ damage. While access to diabetes education centers and diabetes intensification management has been shown to improve blood glucose control, these services are not available to all that require them, particularly in rural and northern areas. The provision of these services through the Home Care team is an advance that can overcome these barriers. Transfer of blood glucose data electronically from the home to the health care provider may improve diabetes management. Methods and design The study population will consist of patients with type 2 diabetes with uncontrolled A1c levels living on reserve in the Battlefords region of Saskatchewan, Canada. This pilot study will take place over three phases. In the first phase over three months the impact of the introduction of the Bluetooth enabled glucose monitor will be assessed. In the second phase over three months, the development of guidelines based treatment algorithms for diabetes intensification will be completed. In the third phase lasting 18 months, study subjects will have diabetes intensification according to the algorithms developed. Discussion The first phase will determine if the use of the Bluetooth enabled blood glucose devices which can transmit results electronically will lead to changes in A1c levels. It will also determine the feasibility of recruiting subjects to use this technology. The rest of the Diabetes Risk Evaluation and Management Tele-monitoring (DreamTel study will determine if the delivery of a diabetes intensification management program by the Home Care team supported by the Bluetooth enabled glucose meters leads to improvements in diabetes management. Trial Registration Protocol NCT00325624

  10. Establishing treatment protocols for clinical mastitis.

    Science.gov (United States)

    Roberson, Jerry R

    2003-03-01

    Each farm has a unique mix of mastitis pathogens and management procedures that have evolved over time. The herd veterinarian should work with the manager/owner to systematically develop treatment protocols that meet the needs and management of the farm. To establish a mastitis treatment protocol, it is necessary to develop a system to routinely identify clinical mastitis cases, develop a herd-specific severity level assessment system, manage the clinical mastitis cases based on severity level and culture result (when available), avoid antibiotic residues, and monitor the success of the system and alter the protocol as necessary.

  11. Adaptive behaviors of experts in following standard protocol in trauma management: implications for developing flexible guidelines.

    Science.gov (United States)

    Vankipuram, Mithra; Ghaemmaghami, Vafa; Patel, Vimla L

    2012-01-01

    Critical care environments are complex and dynamic. To adapt to such environments, clinicians may be required to make alterations to their workflows resulting in deviations from standard procedures. In this work, deviations from standards in trauma critical care are studied. Thirty trauma cases were observed in a Level 1 trauma center. Activities tracked were compared to the Advance Trauma Life Support standard to determine (i) if deviations had occurred, (ii) type of deviations and (iii) whether deviations were initiated by individuals or collaboratively by the team. Results show that expert clinicians deviated to innovate, while deviations of novices result mostly in error. Experts' well developed knowledge allows for flexibility and adaptiveness in dealing with standards, resulting in innovative deviations while minimizing errors made. Providing informatics solution, in such a setting, would mean that standard protocols would have be flexible enough to "learn" from new knowledge, yet provide strong support for the trainees.

  12. Experimental Evaluation of Simulation Abstractions for Wireless Sensor Network MAC Protocols

    Directory of Open Access Journals (Sweden)

    G. P. Halkes

    2010-01-01

    Full Text Available The evaluation of MAC protocols for Wireless Sensor Networks (WSNs is often performed through simulation. These simulations necessarily abstract away from reality in many ways. However, the impact of these abstractions on the results of the simulations has received only limited attention. Moreover, many studies on the accuracy of simulation have studied either the physical layer and per link effects or routing protocol effects. To the best of our knowledge, no other work has focused on the study of the simulation abstractions with respect to MAC protocol performance. In this paper, we present the results of an experimental study of two often used abstractions in the simulation of WSN MAC protocols. We show that a simple SNR-based reception model can provide quite accurate results for metrics commonly used to evaluate MAC protocols. Furthermore, we provide an analysis of what the main sources of deviation are and thereby how the simulations can be improved to provide even better results.

  13. Introducing the Mean Absolute Deviation "Effect" Size

    Science.gov (United States)

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  14. Monitoring fish distributions along electrofishing segments

    Science.gov (United States)

    Miranda, Leandro E.

    2014-01-01

    Electrofishing is widely used to monitor fish species composition and relative abundance in streams and lakes. According to standard protocols, multiple segments are selected in a body of water to monitor population relative abundance as the ratio of total catch to total sampling effort. The standard protocol provides an assessment of fish distribution at a macrohabitat scale among segments, but not within segments. An ancillary protocol was developed for assessing fish distribution at a finer scale within electrofishing segments. The ancillary protocol was used to estimate spacing, dispersion, and association of two species along shore segments in two local reservoirs. The added information provided by the ancillary protocol may be useful for assessing fish distribution relative to fish of the same species, to fish of different species, and to environmental or habitat characteristics.

  15. Validation of A&D TM-2430 upper-arm blood pressure monitor for ambulatory blood pressure monitoring in children and adolescents, according to the British Hypertension Society protocol.

    Science.gov (United States)

    Yip, Gabriel Wai-Kwok; So, Hung-Kwan; Li, Albert Martin; Tomlinson, Brian; Wong, Sik-Nin; Sung, Rita Yn-Tz

    2012-04-01

    The A&D TM-2430 ambulatory blood pressure (BP) monitor has been validated in adults but not in a young population. We sought to validate the device monitoring in children and adolescents, according to the British Hypertension Society (BHS) protocol. The A&D TM-2430 is an automated oscillometric upper-arm device for ambulatory BP monitoring. Nine consecutive measurements were taken in 61 children (mean age, 9.8 years; range, 5-15 years) according to the BHS criteria. Overseen by an independent supervisor, measurements were recorded by two observers blinded from each other's readings and from the device readings. The mean difference ± SD between the observers and device measurements was 0.73 ± 1.64 mmHg for systolic blood pressure (SBP) and -1.23 ± 1.65 mmHg for diastolic blood pressure (DBP), respectively, with an interobserver difference of 4 mmHg. The cumulative percentages of differences within 5, 10, and 15 mmHg were 89, 95, and 98% for SBP and 67, 88, and 98% for DBP. The device achieved a grade A rating for SBP and a B grade for DBP. The A&D TM-2430 upper-arm BP monitor has fulfilled the required BHS standards and can be recommended for measuring ambulatory BP in children and adolescent populations.

  16. Fidelity deviation in quantum teleportation

    Science.gov (United States)

    Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir

    2018-04-01

    We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel—we here consider the so-called Werner channel. To characterize our results, we introduce a 2D space defined by the aforementioned measures, in which the performance of the teleportation is represented as a point with the channel noise parameter. Through further analysis, we specify some regions drawn for different channel conditions, establishing the connection to the dissimilar contributions of the entanglement to the teleportation and the Bell inequality violation.

  17. Large deviations for noninteracting infinite-particle systems

    International Nuclear Information System (INIS)

    Donsker, M.D.; Varadhan, S.R.S.

    1987-01-01

    A large deviation property is established for noninteracting infinite particle systems. Previous large deviation results obtained by the authors involved a single I-function because the cases treated always involved a unique invariant measure for the process. In the context of this paper there is an infinite family of invariant measures and a corresponding infinite family of I-functions governing the large deviations

  18. 48 CFR 1401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 1401.403 Section 1401.403 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL DEPARTMENT OF THE INTERIOR ACQUISITION REGULATION SYSTEM Deviations from the FAR and DIAR 1401.403 Individual...

  19. TERMINOLOGY MANAGEMENT FRAMEWORK DEVIATIONS IN PROJECTS

    Directory of Open Access Journals (Sweden)

    Олена Борисівна ДАНЧЕНКО

    2015-05-01

    Full Text Available The article reviews new approaches to managing projects deviations (risks, changes, problems. By offering integrated control these parameters of the project and by analogy with medical terminological systems building a new system for managing terminological variations in the projects. With an improved method of triads system definitions are analyzed medical terms that make up terminological basis. Using the method of analogy proposed new definitions for managing deviations in projects. By using triad integrity built a new system triad in project management, which will subsequently also analogous to develop a new methodology of deviations in projects.

  20. 41 CFR 115-1.110 - Deviations.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviations. 115-1.110 Section 115-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.110 Deviations...

  1. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong

    2011-08-01

    The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.

  2. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  3. Validation of the Pangao PG-800B11 blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Bing, Sen; Zhang, Cunhai; Wang, Liping; Li, Linyi; Wan, Yi

    2014-12-01

    The study aimed to determine the accuracy of the fully automated oscillometric upper-arm blood pressure (BP) monitor Pangao PG-800B11 according to the European Society of Hypertension-International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocol 1993. Data from 33 participants were initially examined according to the ESH-IP revision 2010. Furthermore, 52 participants were then enrolled to fulfill the BHS protocol requirements. In all participants, sequential left arm measurements were performed by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The protocols' requirements were followed precisely. The device passed all parts of the ESH protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP) and was graded A according to the criteria of the BHS protocol for both SBP and DBP. The A/A grade was achieved in low (160/100 mmHg) BP categories. The mean BP difference between PG-800B11 and observers in the 85 participants was -0.6±5.0 mmHg for SBP and -0.6±4.5 mmHg for DBP; thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation (AAMI). The Pangao PG-800B11 passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol across a wide range of BPs.

  4. 41 CFR 105-1.110 - Deviation.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviation. 105-1.110 Section 105-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) GENERAL SERVICES ADMINISTRATION 1-INTRODUCTION 1.1-Regulations System § 105-1.110 Deviation. (a...

  5. 41 CFR 101-1.110 - Deviation.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Deviation. 101-1.110 Section 101-1.110 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.110 Deviation...

  6. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    Science.gov (United States)

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in

  7. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  8. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    Science.gov (United States)

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  9. Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco

    2015-10-01

    The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.

  10. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  11. Comparing Standard Deviation Effects across Contexts

    Science.gov (United States)

    Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.

    2017-01-01

    Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…

  12. Transport Coefficients from Large Deviation Functions

    Directory of Open Access Journals (Sweden)

    Chloe Ya Gao

    2017-10-01

    Full Text Available We describe a method for computing transport coefficients from the direct evaluation of large deviation functions. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which are scaled cumulant generating functions analogous to the free energies. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green–Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.

  13. Transport Coefficients from Large Deviation Functions

    Science.gov (United States)

    Gao, Chloe; Limmer, David

    2017-10-01

    We describe a method for computing transport coefficients from the direct evaluation of large deviation function. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which is a scaled cumulant generating function analogous to the free energy. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green-Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.

  14. 41 CFR 109-1.110-50 - Deviation procedures.

    Science.gov (United States)

    2010-07-01

    ... best interest of the Government; (3) If applicable, the name of the contractor and identification of... background information which will contribute to a full understanding of the desired deviation. (b)(1... authorized to grant deviations to the DOE-PMR. (d) Requests for deviations from the FPMR will be coordinated...

  15. Background of the implementation of the Protocol the Convention against Torture: Monitoring places of detention and prevention of torture in Uruguay

    Directory of Open Access Journals (Sweden)

    Álvaro Garcé García y Santos

    2014-07-01

    Full Text Available The ratification of the Optional Protocol of the Convention against Torture had for our country, the significance of an ethical and juridical commitment of giving priority to the prevention of abuses for all the people deprived from liberty who are in jails or in other places of detention, as a consequence of a judicial decision or by virtue of an administrative mandate. Among the obligations established by the said Protocol it is found the one of setting up a National Mechanism of Prevention, technically and economically independent, in charge of the systematic monitoring of the detention centers. The creation of the National Institution of Human Rights, together with the legal mandate the same bears to coordinate its duties with the pre-existing Parliamentary Commissioner, finally brings the certain possibility of fulfilling with the obligations arising from the Protocol. At the same time, the original national solution, unparalleled in the region, implies a series of juridical complexities approached in this work. The cooperation between the two State Institutions involved in the matter, so as to avoid a useless overlapping of duties, brings up a promising future in relation to the prevention of torture in Uruguay.

  16. Investigator preparedness for monitoring and audits

    Directory of Open Access Journals (Sweden)

    Renju Ravi

    2018-01-01

    Full Text Available Monitoring and audits are two distinct processes that ensure that the rights and safety of the participants are protected, and data integrity is maintained. The present narrative summates authors' experiences with monitoring and audits by sponsor along with challenges faced by the site. It also offers potential solutions for challenges faced during the process of monitoring and audits. It is important to remember that no monitoring or audit can ever substitute for a well-designed and articulated protocol. In addition, a determined approach by the investigator and his/her team to ensure that all aspects of the protocol are adhered to in totality will go a long way in assuring quality.

  17. Calibration of Community-based Coral Reef Monitoring Protocols ...

    African Journals Online (AJOL)

    Coral reef monitoring (CRM) has been recognised as an important management tool and has consequently been incorporated in Integrated Coastal Area Management (ICAM) programmes in the Western Indian Ocean (WIO). Community-based coral reef monitoring (CB-CRM), which uses simplified procedures suitable for ...

  18. The large deviation approach to statistical mechanics

    International Nuclear Information System (INIS)

    Touchette, Hugo

    2009-01-01

    The theory of large deviations is concerned with the exponential decay of probabilities of large fluctuations in random systems. These probabilities are important in many fields of study, including statistics, finance, and engineering, as they often yield valuable information about the large fluctuations of a random system around its most probable state or trajectory. In the context of equilibrium statistical mechanics, the theory of large deviations provides exponential-order estimates of probabilities that refine and generalize Einstein's theory of fluctuations. This review explores this and other connections between large deviation theory and statistical mechanics, in an effort to show that the mathematical language of statistical mechanics is the language of large deviation theory. The first part of the review presents the basics of large deviation theory, and works out many of its classical applications related to sums of random variables and Markov processes. The second part goes through many problems and results of statistical mechanics, and shows how these can be formulated and derived within the context of large deviation theory. The problems and results treated cover a wide range of physical systems, including equilibrium many-particle systems, noise-perturbed dynamics, nonequilibrium systems, as well as multifractals, disordered systems, and chaotic systems. This review also covers many fundamental aspects of statistical mechanics, such as the derivation of variational principles characterizing equilibrium and nonequilibrium states, the breaking of the Legendre transform for nonconcave entropies, and the characterization of nonequilibrium fluctuations through fluctuation relations.

  19. The large deviation approach to statistical mechanics

    Science.gov (United States)

    Touchette, Hugo

    2009-07-01

    The theory of large deviations is concerned with the exponential decay of probabilities of large fluctuations in random systems. These probabilities are important in many fields of study, including statistics, finance, and engineering, as they often yield valuable information about the large fluctuations of a random system around its most probable state or trajectory. In the context of equilibrium statistical mechanics, the theory of large deviations provides exponential-order estimates of probabilities that refine and generalize Einstein’s theory of fluctuations. This review explores this and other connections between large deviation theory and statistical mechanics, in an effort to show that the mathematical language of statistical mechanics is the language of large deviation theory. The first part of the review presents the basics of large deviation theory, and works out many of its classical applications related to sums of random variables and Markov processes. The second part goes through many problems and results of statistical mechanics, and shows how these can be formulated and derived within the context of large deviation theory. The problems and results treated cover a wide range of physical systems, including equilibrium many-particle systems, noise-perturbed dynamics, nonequilibrium systems, as well as multifractals, disordered systems, and chaotic systems. This review also covers many fundamental aspects of statistical mechanics, such as the derivation of variational principles characterizing equilibrium and nonequilibrium states, the breaking of the Legendre transform for nonconcave entropies, and the characterization of nonequilibrium fluctuations through fluctuation relations.

  20. Transport Coefficients from Large Deviation Functions

    OpenAIRE

    Gao, Chloe Ya; Limmer, David T.

    2017-01-01

    We describe a method for computing transport coefficients from the direct evaluation of large deviation functions. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which are scaled cumulant generating functions analogous to the free energies. A diffusion Monte Carlo algorithm is used to evaluate th...

  1. Dysphonia risk screening protocol

    Science.gov (United States)

    Nemr, Katia; Simões-Zenari, Marcia; da Trindade Duarte, João Marcos; Lobrigate, Karen Elena; Bagatini, Flavia Alves

    2016-01-01

    OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors) divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children), 29.25 (adult women), 22.75 (adult men), and 27.10 (seniors). CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics. PMID:27074171

  2. Dysphonia risk screening protocol

    Directory of Open Access Journals (Sweden)

    Katia Nemr

    2016-03-01

    Full Text Available OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children, 29.25 (adult women, 22.75 (adult men, and 27.10 (seniors. CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics.

  3. Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Tian, Huiyong; Zeng, Sijian; Zhong, Xiaoyan; Gong, Wei; Liu, Wenjun

    2015-10-01

    Transtek blood pressure monitor TMB-1491 is an automatic upper arm device designed for self/home measurement in adult populations. This study aimed to evaluate its accuracy according to the European Society of Hypertension International Protocol revision 2010. The protocol requirements were followed precisely with the recruitment of 33 adult individuals on whom same-left-arm sequential systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements were obtained in this study (three pairs for each of the 33 participants). The device produced 74, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 85, 97, and 99 for DBP, respectively. The mean±SD device-observer difference was -0.6±4.4 mmHg for SBP and -0.6±3.4 mmHg for DBP. The number of participants with two or three device-observer difference within 5 mmHg was 24 for SBP and 29 for DBP. In addition, none of the participants had a device-observer difference within 5 mmHg for SBP, and three of the participants had the same for DBP. Transtek TMB-1491 has passed all phases of European Society of Hypertension International Protocol revision 2010 and can be recommended for self/home measurement in adult populations.

  4. A Simple XML Producer-Consumer Protocol

    Science.gov (United States)

    Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)

    2001-01-01

    performance data. These standard protocols and representations must support tasks such as profiling parallel applications, monitoring the status of computers and networks, and monitoring the performance of services provided by a computational grid. This paper describes a proposed protocol and data representation for the exchange of events in a distributed system. The protocol exchanges messages formatted in XML and it can be layered atop any low-level communication protocol such as TCP or UDP Further, we describe Java and C++ implementations of this protocol and discuss their performance. The next section will provide some further background information. Section 3 describes the main communication patterns of our protocol. Section 4 describes how we represent events and related information using XML. Section 5 describes our protocol and Section 6 discusses the performance of two implementations of the protocol. Finally, an appendix provides the XML Schema definition of our protocol and event information.

  5. Towards a large deviation theory for strongly correlated systems

    International Nuclear Information System (INIS)

    Ruiz, Guiomar; Tsallis, Constantino

    2012-01-01

    A large-deviation connection of statistical mechanics is provided by N independent binary variables, the (N→∞) limit yielding Gaussian distributions. The probability of n≠N/2 out of N throws is governed by e −Nr , r related to the entropy. Large deviations for a strong correlated model characterized by indices (Q,γ) are studied, the (N→∞) limit yielding Q-Gaussians (Q→1 recovers a Gaussian). Its large deviations are governed by e q −Nr q (∝1/N 1/(q−1) , q>1), q=(Q−1)/(γ[3−Q])+1. This illustration opens the door towards a large-deviation foundation of nonextensive statistical mechanics. -- Highlights: ► We introduce the formalism of relative entropy for a single random binary variable and its q-generalization. ► We study a model of N strongly correlated binary random variables and their large-deviation probabilities. ► Large-deviation probability of strongly correlated model exhibits a q-exponential decay whose argument is proportional to N, as extensivity requires. ► Our results point to a q-generalized large deviation theory and suggest a large-deviation foundation of nonextensive statistical mechanics.

  6. FINDING STANDARD DEVIATION OF A FUZZY NUMBER

    OpenAIRE

    Fokrul Alom Mazarbhuiya

    2017-01-01

    Two probability laws can be root of a possibility law. Considering two probability densities over two disjoint ranges, we can define the fuzzy standard deviation of a fuzzy variable with the help of the standard deviation two random variables in two disjoint spaces.

  7. Computed tomography-based lung nodule volumetry - do optimized reconstructions of routine protocols achieve similar accuracy, reproducibility and interobserver variability to that of special volumetry protocols?

    International Nuclear Information System (INIS)

    Bolte, H.; Riedel, C.; Knoess, N.; Hoffmann, B.; Heller, M.; Biederer, J.; Freitag, S.

    2007-01-01

    Purpose: The aim of this in vitro and ex vivo CT study was to investigate whether the use of a routine thorax protocol (RTP) with optimized reconstruction parameters can provide comparable accuracy, reproducibility and interobserver variability of volumetric analyses to that of a special volumetry protocol (SVP). Materials and Methods: To assess accuracy, 3 polyurethane (PU) spheres (35 HU; diameters: 4, 6 and 10 mm) were examined with a recommended SVP using a multislice CT (collimation 16 x 0.75 mm, pitch 1.25, 20 mAs, slice thickness 1 mm, increment 0.7 mm, medium kernel) and an optimized RTP (collimation 16 x 1.5 mm, pitch 1.25, 100 mAs, reconstructed slice thickness 2 mm, increment 0.4 mm, sharp kernel). For the assessment of intrascan and interscan reproducibility and interobserver variability, 20 artificial small pulmonary nodules were placed in a dedicated ex vivo chest phantom and examined with identical scan protocols. The artificial lesions consisted of a fat-wax-Lipiodol registered mixture. Phantoms and ex vivo lesions were examined afterwards using commercial volumetry software. To describe accuracy the relative deviations from the true volumes of the PU phantoms were calculated. For intrascan and interscan reproducibility and interobserver variability, the 95 % normal range (95 % NR) of relative deviations between two measurements was calculated. Results: For the SVP the achieved relative deviations for the 4, 6 and 10 mm PU phantoms were - 14.3 %, - 12.7 % and - 6.8 % and were 4.5 %, - 0.6 % and - 2.6 %, respectively, for the optimized RTP. SVP showed a 95 % NR of 0 - 1.5 % for intrascan and a 95 % NR of - 10.8 - 2.9 % for interscan reproducibility. The 95 % NR for interobserver variability was - 4.3 - 3.3 %. The optimized RTP achieved a 95 % NR of - 3.1 - 4.3 % for intrascan reproducibility and a 95 % NR of - 7.0 - 3.5 % for interscan reproducibility. The 95 % NR for interobserver variability was - 0.4 - 6.8 %. (orig.)

  8. Comparative Analysis of Different Protocols to Manage Large Scale Networks

    OpenAIRE

    Anil Rao Pimplapure; Dr Jayant Dubey; Prashant Sen

    2013-01-01

    In recent year the numbers, complexity and size is increased in Large Scale Network. The best example of Large Scale Network is Internet, and recently once are Data-centers in Cloud Environment. In this process, involvement of several management tasks such as traffic monitoring, security and performance optimization is big task for Network Administrator. This research reports study the different protocols i.e. conventional protocols like Simple Network Management Protocol and newly Gossip bas...

  9. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2017-05-01

    Full Text Available This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks.

  10. The large deviations theorem and ergodicity

    International Nuclear Information System (INIS)

    Gu Rongbao

    2007-01-01

    In this paper, some relationships between stochastic and topological properties of dynamical systems are studied. For a continuous map f from a compact metric space X into itself, we show that if f satisfies the large deviations theorem then it is topologically ergodic. Moreover, we introduce the topologically strong ergodicity, and prove that if f is a topologically strongly ergodic map satisfying the large deviations theorem then it is sensitively dependent on initial conditions

  11. Large deviations

    CERN Document Server

    Deuschel, Jean-Dominique; Deuschel, Jean-Dominique

    2001-01-01

    This is the second printing of the book first published in 1988. The first four chapters of the volume are based on lectures given by Stroock at MIT in 1987. They form an introduction to the basic ideas of the theory of large deviations and make a suitable package on which to base a semester-length course for advanced graduate students with a strong background in analysis and some probability theory. A large selection of exercises presents important material and many applications. The last two chapters present various non-uniform results (Chapter 5) and outline the analytic approach that allow

  12. PoDMan: Policy Deviation Management

    Directory of Open Access Journals (Sweden)

    Aishwarya Bakshi

    2017-07-01

    Full Text Available Whenever an unexpected or exceptional situation occurs, complying with the existing policies may not be possible. The main objective of this work is to assist individuals and organizations to decide in the process of deviating from policies and performing a non-complying action. The paper proposes utilizing software agents as supportive tools to provide the best non-complying action while deviating from policies. The article also introduces a process in which the decision on the choice of non-complying action can be made. The work is motivated by a real scenario observed in a hospital in Norway and demonstrated through the same settings.

  13. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  14. Quantum uncertainty relation based on the mean deviation

    OpenAIRE

    Sharma, Gautam; Mukhopadhyay, Chiranjib; Sazim, Sk; Pati, Arun Kumar

    2018-01-01

    Traditional forms of quantum uncertainty relations are invariably based on the standard deviation. This can be understood in the historical context of simultaneous development of quantum theory and mathematical statistics. Here, we present alternative forms of uncertainty relations, in both state dependent and state independent forms, based on the mean deviation. We illustrate the robustness of this formulation in situations where the standard deviation based uncertainty relation is inapplica...

  15. Exploring Students' Conceptions of the Standard Deviation

    Science.gov (United States)

    delMas, Robert; Liu, Yan

    2005-01-01

    This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…

  16. Routine environmental monitoring schedule, calendar year 1995

    International Nuclear Information System (INIS)

    Schmidt, J.W.; Markes, B.M.; McKinney, S.M.

    1994-12-01

    This document provides Bechtel Hanford, Inc. (BHI) and Westinghouse Hanford Company (WHC) a schedule of monitoring and sampling routines for the Operational Environmental Monitoring (OEM) program during calendar year (CY) 1995. Every attempt will be made to consistently follow this schedule; any deviation from this schedule will be documented by an internal memorandum (DSI) explaining the reason for the deviation. The DSI will be issued by the scheduled performing organization and directed to Near-Field Monitoring. The survey frequencies for particular sites are determined by the technical judgment of Near-Field Monitoring and may depend on the site history, radiological status, use and general conditions. Additional surveys may be requested at irregular frequencies if conditions warrant. All radioactive wastes sites are scheduled to be surveyed at least annually. Any newly discovered wastes sites not documented by this schedule will be included in the revised schedule for CY 1995

  17. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  18. Protocol Monitoring Passive Solar Energy. Background document

    International Nuclear Information System (INIS)

    Van den Ham, E.R.

    1998-01-01

    A method has been developed by means of which the contribution of passive solar energy to the Dutch energy balance can be quantified univocally. The monitoring will be directed at the absolute amount of used solar energy, the relative contribution of passive solar energy to the energy demand in the Netherlands, and the average efficiency of passive solar energy systems. Based on a model of the total building stock the quantities to be monitored can be determined. The most important parameters in the model are: the window surface per orientation, the average U-value (heat transfer coefficient) of windows, the average ZTA-value (incoming solar radiation factor) of windows, and the presence of sun lounges and atriums

  19. Multiplicative surrogate standard deviation: a group metric for the glycemic variability of individual hospitalized patients.

    Science.gov (United States)

    Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey

    2013-09-01

    Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.

  20. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients.

    Science.gov (United States)

    Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan

    2008-04-01

    Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.

  1. Two examples of non strictly convex large deviations

    OpenAIRE

    De Marco, Stefano; Jacquier, Antoine; Roome, Patrick

    2016-01-01

    We present two examples of a large deviations principle where the rate function is not strictly convex. This is motivated by a model used in mathematical finance (the Heston model), and adds a new item to the zoology of non strictly convex large deviations. For one of these examples, we show that the rate function of the Cramer-type of large deviations coincides with that of the Freidlin-Wentzell when contraction principles are applied.

  2. A Visual Model for the Variance and Standard Deviation

    Science.gov (United States)

    Orris, J. B.

    2011-01-01

    This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.

  3. 7 CFR 400.204 - Notification of deviation from standards.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...

  4. Dose deviations caused by positional inaccuracy of multileaf collimator in intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Wang, H.C.; Chui, C.S.; Tsai, H.Y.; Chen, C.H.; Tsai, L.F.

    2008-01-01

    the dose errors. The algorithms generating more segments result more errors. However, the dose error distributions really relate to the irradiated angles. Conclusions: Each department should figure out the dose errors from MLC positional inaccuracy with the treatment machines and the clinical protocols in their institute. To ensure the dose deviations within acceptance level, the criteria setting of MLC accuracy is necessary

  5. Smart Traffic Management Protocol Based on VANET architecture

    Directory of Open Access Journals (Sweden)

    Amilcare Francesco Santamaria

    2014-01-01

    Full Text Available Nowadays one of the hottest theme in wireless environments research is the application of the newest technologies to road safety problems and traffic management exploiting the (VANET architecture. In this work, a novel protocol that aims to achieve a better traffic management is proposed. The overal system is able to reduce traffic level inside the city exploiting inter-communication among vehicles and support infrastructures also known as (V2V and (V2I communications. We design a network protocol called (STMP that takes advantages of IEEE 802.11p standard. On each road several sensors system are placed and they are responsible of monitoring. Gathered data are spread in the network exploiting ad-hoc protocol messages. The increasing knowledge about environment conditions make possible to take preventive actions. Moreover, having a realtime monitoring of the lanes it is possible to reveal roads and city blocks congestions in a shorter time. An external entity to the (VANET is responsible to manage traffic and rearrange traffic along the lanes of the city avoiding huge traffic levels.

  6. Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Lin, Emile N.J.Th. van; Nijenhuis, Edwin; Huizenga, Henk; Vight, Lisette van der; Visser, Andries

    2001-01-01

    Purpose: To investigate set-up improvement caused by applying a couch height-based patient set-up method in combination with a technologist-driven off-line correction protocol in nonimmobilized radiotherapy of prostate patients. Methods and Materials: A three-dimensional shrinking action level correction protocol is applied in two consecutive patient cohorts with different set-up methods: the traditional 'laser set-up' group (n=43) and the 'couch height set-up' group (n=112). For all directions, left-right, ventro-dorsal, and cranio-caudal, random and systematic set-up deviations were measured. Results: The couch height set-up method improves the patient positioning compared to the laser set-up method. Without application of the correction protocol, both systematic and random errors reduced to 2.2-2.4 mm (1 SD) and 1.7-2.2 mm (1 SD), respectively. By using the correction protocol, systematic errors reduced further to 1.3-1.6 mm (1 SD). One-dimensional deviations were within 5 mm for >90% of the measured fractions. The required number of corrections per patient in the off-line correction protocol was reduced significantly during the course of treatment from 1.1 to 0.6 by the couch height set-up method. The treatment time was not prolonged by application of the correction protocol. Conclusions: The couch height set-up method improves the set-up significantly, especially in the ventro-dorsal direction. Combination of this set-up method with an off-line correction strategy, executed by technologists, reduces the number of set-up corrections required

  7. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  8. A Survey on Temperature-Aware Routing Protocols in Wireless Body Sensor Networks

    Directory of Open Access Journals (Sweden)

    Sangman Moh

    2013-08-01

    Full Text Available The rapid growth of the elderly population in the world and the rising cost of healthcare impose big issues for healthcare and medical monitoring. A Wireless Body Sensor Network (WBSN is comprised of small sensor nodes attached inside, on or around a human body, the main purpose of which is to monitor the functions and surroundings of the human body. However, the heat generated by the node’s circuitry and antenna could cause damage to the human tissue. Therefore, in designing a routing protocol for WBSNs, it is important to reduce the heat by incorporating temperature into the routing metric. The main contribution of this paper is to survey existing temperature-aware routing protocols that have been proposed for WBSNs. In this paper, we present a brief overview of WBSNs, review the existing routing protocols comparatively and discuss challenging open issues in the design of routing protocols.

  9. Sensitivity Analysis of Deviation Source for Fast Assembly Precision Optimization

    Directory of Open Access Journals (Sweden)

    Jianjun Tang

    2014-01-01

    Full Text Available Assembly precision optimization of complex product has a huge benefit in improving the quality of our products. Due to the impact of a variety of deviation source coupling phenomena, the goal of assembly precision optimization is difficult to be confirmed accurately. In order to achieve optimization of assembly precision accurately and rapidly, sensitivity analysis of deviation source is proposed. First, deviation source sensitivity is defined as the ratio of assembly dimension variation and deviation source dimension variation. Second, according to assembly constraint relations, assembly sequences and locating, deviation transmission paths are established by locating the joints between the adjacent parts, and establishing each part’s datum reference frame. Third, assembly multidimensional vector loops are created using deviation transmission paths, and the corresponding scalar equations of each dimension are established. Then, assembly deviation source sensitivity is calculated by using a first-order Taylor expansion and matrix transformation method. Finally, taking assembly precision optimization of wing flap rocker as an example, the effectiveness and efficiency of the deviation source sensitivity analysis method are verified.

  10. Development of a monitoring protocol to enhance mentoring in the IRIS REU site

    Science.gov (United States)

    Hubenthal, M.; Brudzinski, M. R.; Colella, H.

    2013-12-01

    Research Experiences for Undergraduate (REU) sites pair interns with scientists expected to oversee and guide an intern's scientific research, and assist in the development of skills, knowledge, and connections that will enhance the intern's professional and personal growth. This aspect of REU sites is generally recognized as a powerful, yet complicated, component that has a strong influence on the overall success of the intern's experience. Evaluations indicate that the quality and consistency of mentoring in REU sites can be highly variable. Traditional strategies to influence mentorship generally include reading lists or short trainings at the beginning of the summer. The efficacy of these approaches is questionable. As a result many REU Site facilitators are deeply interested in the question 'How can REU programs challenge scientists to raise their participation to the level of (truly) mentoring?' The Incorporated Research Institutions for Seismology (IRIS) REU site is developing a 13-item rubric measuring research skills, and a protocol of training and intern-mentor meetings to discuss progress. The goal of the intervention is to both increase the extent to which the mentoring relationship is centered on the intern, and to enable interns and mentors to feel more effective monitoring interns' personal/professional growth. This intervention was piloted in 2011, refined, and fully implemented in 2012. During the initial week of the program, interns assess their skills, complete the rubric independently, and discuss the completed rubric with their mentor. Midway through the summer interns and mentors each review the rubric and assess the intern's skills. The intern-mentor pairs then meet to collaborate and complete the rubric together. Finally, in the last week of the program, interns and mentors independently assess the intern's skills and complete the rubric, and the pairs again meet to discuss and negotiate these independent assessments. Survey data from 2012

  11. Automatic classification of transient ischaemic and transient non-ischaemic heart-rate related ST segment deviation episodes in ambulatory ECG records

    International Nuclear Information System (INIS)

    Faganeli, J; Jager, F

    2010-01-01

    In ambulatory ECG records, besides transient ischaemic ST segment deviation episodes, there are also transient non-ischaemic heart-rate related ST segment deviation episodes present, which appear only due to a change in heart rate and thus complicate automatic detection of true ischaemic episodes. The goal of this work was to automatically classify these two types of episodes. The tested features to classify the ST segment deviation episodes were changes of heart rate, changes of the Mahalanobis distance of the first five Karhunen–Loève transform (KLT) coefficients of the QRS complex, changes of time-domain morphologic parameters of the ST segment and changes of the Legendre orthonormal polynomial coefficients of the ST segment. We chose Legendre basis functions because they best fit typical shapes of the ST segment morphology, thus allowing direct insight into the ST segment morphology changes through the feature space. The classification was performed with the help of decision trees. We tested the classification method using all records of the Long-Term ST Database on all ischaemic and all non-ischaemic heart-rate related deviation episodes according to annotation protocol B. In order to predict the real-world performance of the classification we used second-order aggregate statistics, gross and average statistics, and the bootstrap method. We obtained the best performance when we combined the heart-rate features, the Mahalanobis distance and the Legendre orthonormal polynomial coefficient features, with average sensitivity of 98.1% and average specificity of 85.2%

  12. The Development of Smart Home System for Controlling and Monitoring Energy Consumption using WebSocket Protocol

    Science.gov (United States)

    Witthayawiroj, Niti; Nilaphruek, Pongpon

    2017-03-01

    Energy consumption especially electricity is considered one of the most serious problems in households these days. It is because the amount of electricity consumed is more than the amount that people actually need. This means that there is an overusing which resulted from the inconvenience of moving to the switch to turn off the light or any appliances and it is often that closing the light is forgettable, for instance; in addition, there are no tools for monitoring how much energy that is consumed in residents. From this, it can be easily seen that people are having a problem in energy usage monitor and control. There are two main objectives of this study including 1) creating the communication framework among server, clients and devices, and 2) developing the prototype system that try to solve the mentioned problems which gives the user an opportunity to know the amount of electricity they have used in their houses and also the ability to turn appliances on and off through the Internet on smart devices such as smart phones and tablets that support Android platform or any web browser. Raspberry Pi is used as a microcontroller and the data is transferred to the smart device by WebSocket protocol which is strongly recommended for real-time communication. The example features on the device’s screen are user management, controlling and monitoring of appliances. The result expresses that the system is very effective and not difficult to use from users’ satisfaction. However, current sensors may be used for a more accurate electricity measurement and Wi-Fi module for more appliances to calculate its power in the future.

  13. Surgery versus Active Monitoring in Intermittent Exotropia (SamExo: study protocol for a pilot randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Buck Deborah

    2012-10-01

    Full Text Available Abstract Background Childhood intermittent exotropia [X(T] is a type of strabismus (squint in which one eye deviates outward at times, usually when the child is tired. It may progress to a permanent squint, loss of stereovision and/or amblyopia (reduced vision. Treatment options for X(T include eye patches, glasses, surgery and active monitoring. There is no consensus regarding how this condition should be managed, and even when surgery is the preferred option clinicians disagree as to the optimal timing. Reports on the natural history of X(T are limited, and there is no randomised controlled trial (RCT evidence on the effectiveness or efficiency of surgery compared with active monitoring. The SamExo (Surgery versus Active Monitoring in Intermittent Exotropia pilot study has been designed to test the feasibility of such a trial in the UK. Methods Design: an external pilot patient randomised controlled trial. Setting: four UK secondary ophthalmology care facilities at Newcastle NHS Hospitals Foundation Trust, Sunderland Eye Infirmary, Moorfields Eye Hospital and York NHS Trust. Participants: children aged between 6 months and 16 years referred with suspected and subsequently diagnosed X(T. Recruitment target is a total of 144 children over a 9-month period, with 120 retained by 9-month outcome visit. Randomisation: permuted blocks stratified by collaborating centre, age and severity of X(T. Interventions: initial clinical assessment; randomisation (eye muscle surgery or active monitoring; 3-, 6- and 9-month (primary outcome clinical assessments; participant/proxy completed questionnaire covering time and travel costs, health services use and quality of life (Intermittent Exotropia Questionnaire; qualitative interviews with parents to establish reasons for agreeing or declining participation in the pilot trial. Outcomes: recruitment and retention rates; nature and extent of participation bias; nature and extent of biases arising from crossover or

  14. Perception of midline deviations in smile esthetics by laypersons.

    Science.gov (United States)

    Ferreira, Jamille Barros; Silva, Licínio Esmeraldo da; Caetano, Márcia Tereza de Oliveira; Motta, Andrea Fonseca Jardim da; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson

    2016-01-01

    To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student's t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation.

  15. Monitors display of radiological images: quality control and response of the observer; Monitores de visualizacion de imagenes radiologicas: control de calidad y respuesta del observador

    Energy Technology Data Exchange (ETDEWEB)

    Cesares Magaz, O.; Catalan Acosta, A.; Hernandez Armas, O. C.; Gonzalez Martin, A. E.; Hernandez Armas, J.

    2011-07-01

    This thesis is aimed to determine the possible change experienced by a human reader response to the qualification of a test image on a monitor diagnostic radiographic image when observed before and after calibration of the monitor following the provisions of the AAPM TG18 protocol. It also quantified the change experienced by the monitor as a result of the calibration, by measuring the luminance response as set out in the protocol.

  16. Effect of nasal deviation on quality of life.

    Science.gov (United States)

    de Lima Ramos, Sueli; Hochman, Bernardo; Gomes, Heitor Carvalho; Abla, Luiz Eduardo Felipe; Veiga, Daniela Francescato; Juliano, Yara; Dini, Gal Moreira; Ferreira, Lydia Masako

    2011-07-01

    Nasal deviation is a common complaint in otorhinolaryngology and plastic surgery. This condition not only causes impairment of nasal function but also affects quality of life, leading to psychological distress. The subjective assessment of quality of life, as an important aspect of outcomes research, has received increasing attention in recent decades. Quality of life is measured using standardized questionnaires that have been tested for reliability, validity, and sensitivity. The aim of this study was to evaluate health-related quality of life, self-esteem, and depression in patients with nasal deviation. Sixty patients were selected for the study. Patients with nasal deviation (n = 32) were assigned to the study group, and patients without nasal deviation (n = 28) were assigned to the control group. The diagnosis of nasal deviation was made by digital photogrammetry. Quality of life was assessed using the Medical Outcomes Study 36-Item Short Form Health Survey questionnaire; the Rosenberg Self-Esteem/Federal University of São Paulo, Escola Paulista de Medicina Scale; and the 20-item Self-Report Questionnaire. There were significant differences between groups in the physical functioning and general health subscales of the Medical Outcomes Study 36-Item Short Form Health Survey (p < 0.05). Depression was detected in 11 patients (34.4 percent) in the study group and in two patients in the control group, with a significant difference between groups (p < 0.05). Nasal deviation is an aspect of rhinoplasty of which the surgeon should be aware so that proper psychological diagnosis can be made and suitable treatment can be planned because psychologically the patients with nasal deviation have significantly worse quality of life and are more prone to depression. Risk, II.(Figure is included in full-text article.).

  17. Comparison of the BPLab® sphygmomanometer for ambulatory blood pressure monitoring with mercury sphygmomanometry in pregnant women: validation study according to the British Hypertension Society protocol

    Directory of Open Access Journals (Sweden)

    Dorogova IV

    2015-04-01

    Full Text Available Inna V Dorogova, Elena S Panina Penza Institute of Advanced Training for Physicians, Penza, RussiaAbstract: The purpose of this study was to validate the automated BPLab® sphygmomanometer for ambulatory blood pressure monitoring (ABPM in pregnant women according to Part II of the 1993 British Hypertension Society protocol. Pregnant women attending the antenatal clinic were randomly asked to participate (n=30. The BPLab sphygmomanometer was tested on pregnant women in this study and achieved A/A ratings according to the BHS protocol when compared with the “gold” standard of mercury sphygmomanometry. The device can therefore be recommended for use in pregnancy.Keywords: pregnancy, BPLab, blood pressure measuring

  18. Distributed Network Protocols

    Science.gov (United States)

    1980-07-01

    MONITORING AGENCY NAME & ADDRESS(II different from Controlting Office) IS. SECURITY CLASS. (of this report) S Office of Naval Research Unclassified...All protocols are extended to networks with changing. topology. S80 8 4 246 DD0I iA 1473 EDITION OF INOV 65 IS OBSOLETE 8 0 24 SECURITY CLASSIFICATION...to the netowrk . f) Each node knows its adjacent links, but not necessarily the identity of its neighbors, i.e. the nodes at the other end of the links

  19. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  20. Time-of-flight PET/CT using low-activity protocols: potential implications for cancer therapy monitoring

    International Nuclear Information System (INIS)

    Murray, Iain; Hasan, Syed; Quraishi, Shuaib; Avril, Norbert; Kalemis, Antonis; Glennon, Joe; Beyer, Thomas

    2010-01-01

    Accurate quantification of tumour tracer uptake is essential for therapy monitoring by sequential PET imaging. In this study we investigated to what extent a reduction in administered activity, synonymous with an overall reduction in repeated patient exposure, compromised the accuracy of quantitative measures using time-of-flight PET/CT. We evaluated the effect of reducing the emission count statistics, using a 64-channel GEMINI TF PET/CT system. Experiments were performed with the NEMA IEC body phantom at target-to-background ratios of 4:1 and 10:1. Emission data for 10 s, 30 s, 1 min, 2 min, 5 min and 30 min were acquired. Volumes of interest fitted to the CT outline of the spheres were used to calculate recovery coefficients for each target-to-background ratio and for different reconstruction algorithms. Whole-body time-of-flight PET/CT was performed in 20 patients 62±4 min after injection of 350±40 MBq (range 269-411 MBq) 18 F-FDG. From the acquired 2 min per bed position list mode data, simulated 1-min, 30-s and 15-s PET acquisitions were created. PET images were reconstructed using the TOF-OSEM algorithm and analysed for differences in SUV measurements resulting from the use of lower administered activity as simulated by reduced count statistics. In the phantom studies, overall we identified no significant quantitation bias over a wide range of acquired counts. With acquisition times as short as 10 s, lesions as small as 1 cm in diameter could still be identified. In the patient studies, visual analysis showed that emission scans as short as 15 s per bed position sufficiently identified tumour lesions for quantification. As the acquisition time per bed position decreased, the differences in SUV quantification of tumour lesions increased relative to the 2-min reference protocol. However, SUVs remained within the limits of reproducibility required for therapy monitoring. Measurements of SUVmean within the region of interest were less prone to noise than

  1. Physical activity monitors to enhance the daily amount of physical activity in elderly-a protocol for a systematic review and meta-analysis

    DEFF Research Database (Denmark)

    Larsen, Rasmus Tolstrup; Christensen, Jan; Juhl, Carsten Bogh

    2018-01-01

    To investigate the use of physical activity monitors (PAMs) for the elderly, the scientific literature should be systematically reviewed and the effect quantified, as the evidence seems inconclusive. Randomized controlled trials and randomized crossover trials, with participants with a mean age...... above 65 years, comparing any PAM intervention with other control interventions or no intervention, will be included. This protocol is detailed according to the recommendations of the Cochrane Handbook, and it is reported according to the Preferred Reporting Items for Systematic Reviews and Meta...

  2. Association between septal deviation and sinonasal papilloma.

    Science.gov (United States)

    Nomura, Kazuhiro; Ogawa, Takenori; Sugawara, Mitsuru; Honkura, Yohei; Oshima, Hidetoshi; Arakawa, Kazuya; Oshima, Takeshi; Katori, Yukio

    2013-12-01

    Sinonasal papilloma is a common benign epithelial tumor of the sinonasal tract and accounts for 0.5% to 4% of all nasal tumors. The etiology of sinonasal papilloma remains unclear, although human papilloma virus has been proposed as a major risk factor. Other etiological factors, such as anatomical variations of the nasal cavity, may be related to the pathogenesis of sinonasal papilloma, because deviated nasal septum is seen in patients with chronic rhinosinusitis. We, therefore, investigated the involvement of deviated nasal septum in the development of sinonasal papilloma. Preoperative computed tomography or magnetic resonance imaging findings of 83 patients with sinonasal papilloma were evaluated retrospectively. The side of papilloma and the direction of septal deviation showed a significant correlation. Septum deviated to the intact side in 51 of 83 patients (61.4%) and to the affected side in 18 of 83 patients (21.7%). Straight or S-shaped septum was observed in 14 of 83 patients (16.9%). Even after excluding 27 patients who underwent revision surgery and 15 patients in whom the papilloma touched the concave portion of the nasal septum, the concave side of septal deviation was associated with the development of sinonasal papilloma (p = 0.040). The high incidence of sinonasal papilloma in the concave side may reflect the consequences of the traumatic effects caused by wall shear stress of the high-velocity airflow and the increased chance of inhaling viruses and pollutants. The present study supports the causative role of human papilloma virus and toxic chemicals in the occurrence of sinonasal papilloma.

  3. Absorbed dose to water comparison between NE 2561 and NE 2671 chambers using IAEA, HPA and NACP protocols for gamma ray beam

    International Nuclear Information System (INIS)

    Mohd Taufik Dolah; Noriah Mod Ali; Taiman Kadni

    2002-01-01

    The aim of this study to evaluate the performance of NE 2571 chamber in comparison with NE 2561 chamber in determination of the absorbed dose to water in gamma ray beam. In this study NE 2561 is taking as a reference standard chamber while NE 2571 as a working standard. Irradiation of chamber (alternately) was performed at a reference depth, 5 cm, inside the IAEA water phantom. Both chambers were exposed to 13 difference exposures of gamma rays. The values of absorbed dose to water were then determined using IAEA, HPA and NACP protocols. Deviations of absorbed dose determined by NE 2561 and NE 2571 were calculated for each protocol. result obtained in terms of [protocol, μ (mean deviation) ± σ s e (standard error)] were (IAEA, 1.12 ± 0.04], [HPA, 0.09 ± 0.04], and [NCP, 0.09 ± 0.04]. It can be concluded that NE 2571 shown acceptable performance as it is within acceptable limit ± 3%. (Author)

  4. Hearing protector performance and standard deviation.

    Science.gov (United States)

    Williams, W; Dillon, H

    2005-01-01

    The attenuation performance of a hearing protector is used to estimate the protected exposure level of the user. The aim is to reduce the exposed level to an acceptable value. Users should expect the attenuation to fall within a reasonable range of values around a norm. However, an analysis of extensive test data indicates that there is a negative relationship between attenuation performance and the standard deviation. This result is deduced using a variation in the method of calculating a single number rating of attenuation that is more amenable to drawing statistical inferences. As performance is typically specified as a function of the mean attenuation minus one or two standard deviations from the mean to ensure that greater than 50% of the wearer population are well protected, the implication of increasing standard deviation with decreasing attenuation found in this study means that a significant number of users are, in fact, experiencing over-protection. These users may be disinclined to use their hearing protectors because of an increased feeling of acoustic isolation. This problem is exacerbated in areas with lower noise levels.

  5. Top Yukawa deviation in extra dimension

    International Nuclear Information System (INIS)

    Haba, Naoyuki; Oda, Kin-ya; Takahashi, Ryo

    2009-01-01

    We suggest a simple one-Higgs-doublet model living in the bulk of five-dimensional spacetime compactified on S 1 /Z 2 , in which the top Yukawa coupling can be smaller than the naive standard-model expectation, i.e. the top quark mass divided by the Higgs vacuum expectation value. If we find only single Higgs particle at the LHC and also observe the top Yukawa deviation, our scenario becomes a realistic candidate beyond the standard model. The Yukawa deviation comes from the fact that the wave function profile of the free physical Higgs field can become different from that of the vacuum expectation value, due to the presence of the brane-localized Higgs potentials. In the Brane-Localized Fermion scenario, we find sizable top Yukawa deviation, which could be checked at the LHC experiment, with a dominant Higgs production channel being the WW fusion. We also study the Bulk Fermion scenario with brane-localized Higgs potential, which resembles the Universal Extra Dimension model with a stable dark matter candidate. We show that both scenarios are consistent with the current electroweak precision measurements.

  6. Biopiracy after the Nagoya Protocol: Problem Structure, Regime Design and Implementation Challenges

    Directory of Open Access Journals (Sweden)

    Florian Rabitz

    2015-08-01

    Full Text Available This article assesses the effectiveness of the 2010 Nagoya Protocol to the Convention on Biological Diversity (CBD for addressing "biopiracy" of genetic resources; that is, their biotechnological utilization in violation of either the provider country legislation or mutually agreed contractual obligations. Biopiracy is defined as a problem resulting from a distributive conflict between provider and user countries, the practical difficulties of monitoring the utilization of genetic resources in a transnational context, and the pervasive scientific uncertainty about the nature and extent of the problem. The Nagoya Protocol predominantly focuses on compliance management while lacking the necessary enforcement provisions for deterring non-compliance through effective monitoring and sanctions. Using the example of recent European Union implementing legislation, this article underscores how parties may use the Protocol's legal ambiguities to soften its regulatory impact on domestic industry. As a result, in light of both problem structure and regime design, the Protocol only offers modest improvements over the status quo ante.

  7. Performance evaluation of working standard NE2581 in comparison with reference standard NE2561 in the determination of absorbed dose to water using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols

    International Nuclear Information System (INIS)

    Dolah, M.T.; Supian Samat; Taiman Kadni

    2001-01-01

    The aim of this study was to evaluate the performance of NE 2581 in comparison with NE 2561 in the determination of the absorbed dose to water in a γ-ray beam using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. 13 exposures of the γ-ray beams were used. This number of exposures yielded 26 chamber rate readings for NE 2581 (N=13) and for NE 2561 (N=13). From the 13 NE 2581 readings, 78 absorbed dose to water values were calculated for the IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. Similarly, from the 13 NE 2561 readings, 78 absorbed dose to water values were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. From these 156 (=78 x 2) absorbed dose to water values, 78 percentage deviations between the NE 2581 and NE 2561 results were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. For a single protocol, the mean μ and standard error σ+s+e of the percentage deviations (N=13) were calculated. results obtained in terms of [protocol, μ ± σ se ] were [IAEA,1.55 ± 0.12], [HPA, 0.98 ± 0.12], [NACP, 1.93 ± 0.12], [AAPM, -0.06 ± 0.12], [NCRP, 0.97 ± 0.12], [ICRU, 0.97 ± 0.12]. It can be seen that the range of percentage deviations is from -0.06 to 1.93. As the quoted IAEA acceptable limit of deviation is ± 3.0%, it was concluded that the working standard NE 2581 chamber has shown acceptable performance. In addition, the use of the AAPM protocol has enable NE 2581 to show a performance that is very similar like NE 2561. (Author)

  8. Energy Efficient Clustering Based Network Protocol Stack for 3D Airborne Monitoring System

    Directory of Open Access Journals (Sweden)

    Abhishek Joshi

    2017-01-01

    Full Text Available Wireless Sensor Network consists of large number of nodes densely deployed in ad hoc manner. Usually, most of the application areas of WSNs require two-dimensional (2D topology. Various emerging application areas such as airborne networks and underwater wireless sensor networks are usually deployed using three-dimensional (3D network topology. In this paper, a static 3D cluster-based network topology has been proposed for airborne networks. A network protocol stack consisting of various protocols such as TDMA MAC and dynamic routing along with services such as time synchronization, Cluster Head rotation, and power level management has been proposed for this airborne network. The proposed protocol stack has been implemented on the hardware platform consisting of number of TelosB nodes. This 3D airborne network architecture can be used to measure Air Quality Index (AQI in an area. Various parameters of network such as energy consumption, Cluster Head rotation, time synchronization, and Packet Delivery Ratio (PDR have been analyzed. Detailed description of the implementation of the protocol stack along with results of implementation has been provided in this paper.

  9. Two Phases Authentication Level (TPAL) protocol for nodes ...

    African Journals Online (AJOL)

    ... node may contain sensitive informations such as military data and monitoring data. ... LLN is a kind of Internet of Things (IoT) network with limited power source ... Current authentication Internet protocols cannot be adopted directly into LLN ...

  10. Prosthodontic management of mandibular deviation using palatal ramp appliance

    Directory of Open Access Journals (Sweden)

    Prince Kumar

    2012-08-01

    Full Text Available Segmental resection of the mandible generally results in deviation of the mandible to the defective side. This loss of continuity of the mandible destroys the balance of the lower face and leads to decreased mandibular function by deviation of the residual segment toward the surgical site. Prosthetic methods advocated to reduce or eliminate mandibular deviation include intermaxillary fixation, removable mandibular guide flange, palatal ramp, implant-supported prosthesis and palatal guidance restorations which may be useful in reducing mandibular deviation and improving masticatory performance and efficiency. These methods and restorations would be combined with a well organized mandibular exercise regimen. This clinical report describes the rehabilitation following segmental mandibulectomy using palatal ramp prosthesis.

  11. Scaphoid and lunate movement in different ranges of carpal radioulnar deviation.

    Science.gov (United States)

    Tang, Jin Bo; Xu, Jing; Xie, Ren Guo

    2011-01-01

    We aimed to investigate scaphoid and lunate movement in radial deviation and in slight and moderate ulnar deviation ranges in vivo. We obtained computed tomography scans of the right wrists from 20° radial deviation to 40° ulnar deviation in 20° increments in 6 volunteers. The 3-dimensional bony structures of the wrist, including the distal radius and ulna, were reconstructed with customized software. The changes in position of the scaphoid and lunate along flexion-extension motion (FEM), radioulnar deviation (RUD), and supination-pronation axes in 3 parts--radial deviation and slight and moderate ulnar deviation--of the carpal RUD were calculated and analyzed. During carpal RUD, scaphoid and lunate motion along 3 axes--FEM, RUD, and supination-pronation--were the greatest in the middle third of the measured RUD (from neutral position to 20° ulnar deviation) and the smallest in radial deviation. Scaphoid motion along the FEM, RUD, and supination-pronation axes in the middle third was about half that in the entire motion range. In the middle motion range, lunate movement along the FEM and RUD axes was also the greatest. During carpal RUD, the greatest scaphoid and lunate movement occurs in the middle of the arc--slight ulnar deviation--which the wrist frequently adopts to accomplish major hand actions. At radial deviation, scaphoid and lunate motion is the smallest. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. An absolute deviation approach to assessing correlation.

    OpenAIRE

    Gorard, S.

    2015-01-01

    This paper describes two possible alternatives to the more traditional Pearson’s R correlation coefficient, both based on using the mean absolute deviation, rather than the standard deviation, as a measure of dispersion. Pearson’s R is well-established and has many advantages. However, these newer variants also have several advantages, including greater simplicity and ease of computation, and perhaps greater tolerance of underlying assumptions (such as the need for linearity). The first alter...

  13. 38 CFR 36.4304 - Deviations; changes of identity.

    Science.gov (United States)

    2010-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  14. Moderate deviations principles for the kernel estimator of ...

    African Journals Online (AJOL)

    Abstract. The aim of this paper is to provide pointwise and uniform moderate deviations principles for the kernel estimator of a nonrandom regression function. Moreover, we give an application of these moderate deviations principles to the construction of condence regions for the regression function. Resume. L'objectif de ...

  15. 48 CFR 1352.219-71 - Notification to delay performance (Deviation).

    Science.gov (United States)

    2010-10-01

    ... performance (Deviation). 1352.219-71 Section 1352.219-71 Federal Acquisition Regulations System DEPARTMENT OF....219-71 Notification to delay performance (Deviation). As prescribed in 48 CFR 1319.811-3(b), insert the following clause: Notification To Delay Performance (Deviation) (APR 2010) The contractor shall...

  16. Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Chen, Qi; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2017-04-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor BPUMP BF1112 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010 (ESH-IP2010). Systolic and diastolic BPs were sequentially measured in 33 adult Chinese (13 women, mean age 46.7 years) using a mercury sphygmomanometer (two observers) and the BF1112 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The BPUMP BF1112 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 85/99, 96/99, and 97/99, respectively, for systolic BP, and 83/99, 97/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. A total of 31 and 30 participants for systolic and diastolic BP, respectively, had at least two of the three device-observer differences within 5 mmHg (required≥24mmHg). No participant for systolic or diastolic BP had all the three device-observer comparisons greater than 5 mmHg. The BPUMP BP monitor BF1112 has passed the requirements of the ESH-IP2010, and hence can be recommended for home use in adults.

  17. Ground-based photo monitoring

    Science.gov (United States)

    Frederick C. Hall

    2000-01-01

    Ground-based photo monitoring is repeat photography using ground-based cameras to document change in vegetation or soil. Assume those installing the photo location will not be the ones re-photographing it. This requires a protocol that includes: (1) a map to locate the monitoring area, (2) another map diagramming the photographic layout, (3) type and make of film such...

  18. A survey of an air monitoring program

    International Nuclear Information System (INIS)

    Lee, M.B.

    1997-01-01

    The objective of this report is to compare personal air sampling data to stationary air sampling data and to bioassay data that was taken during the decontamination and decommissioning of sixty-one plutonium glove boxes at Argonne National Laboratory (ANL) in 1995. An air monitoring program administered at Argonne National Laboratory was assessed by comparing personal air sampler (PAS) data, stationary air sampler (SAS) data, and bioassay data. The study revealed that the PAS and SAS techniques were equivalent when averaged over all employees and all workdays, but the standard deviation was large. Also, large deviations were observed in individual samples. The correlation between individual PAS results and bioassay results was low. Personal air samplers and bioassay monitoring played complementary roles in assessing the workplace and estimating intakes. The PAS technique is adequate for detection and evaluation of contaminated atmospheres, whereas bioassay monitoring is better for determining individual intakes

  19. 7 CFR 400.174 - Notification of deviation from financial standards.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...

  20. Direct data access protocols benchmarking on DPM

    CERN Document Server

    Furano, Fabrizio; Keeble, Oliver; Mancinelli, Valentina

    2015-01-01

    The Disk Pool Manager is an example of a multi-protocol, multi-VO system for data access on the Grid that went though a considerable technical evolution in the last years. Among other features, its architecture offers the opportunity of testing its different data access frontends under exactly the same conditions, including hardware and backend software. This characteristic inspired the idea of collecting monitoring information from various testbeds in order to benchmark the behaviour of the HTTP and Xrootd protocols for the use case of data analysis, batch or interactive. A source of information is the set of continuous tests that are run towards the worldwide endpoints belonging to the DPM Collaboration, which accumulated relevant statistics in its first year of activity. On top of that, the DPM releases are based on multiple levels of automated testing that include performance benchmarks of various kinds, executed regularly every day. At the same time, the recent releases of DPM can report monitoring infor...

  1. Resolving issues on terrestrial biospheric sinks in the Kyoto Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Nabuurs, G.J.; Verkaik, E.; Mohren, G.M.J. [DLO Institute for Forestry and Nature Research IBN-DLO, Wageningen (Netherlands); Dolman, A.J.; Kabat, P. [DLO Winand Staring Centre SC-DLO, Wageningen (Netherlands); Whitmore, A.P.; Oenema, O. [DLO Institute for Agrobiology AB-DLO, Wageningen (Netherlands); Daamen, W.P. [Consulatancy Daamen, Schoonderwoerd and De Klein, Kesteren (Netherlands)

    1999-08-01

    In the Kyoto Protocol, all Annex I countries have agreed to reduce their carbon dioxide emissions with a certain percentage in 2008-2012 compared to 1990. To achieve that target, some direct human induced activities initiated in the Land-use Change and Forestry sector since 1990, may be used. However, the wording in the Protocol has caused confusion on what is exactly meant in the Protocol, which activities may be included, whether soils should be included and whether any additional measures may be included in the future. Also, the way of monitoring, verification and reporting is unclear. In this NRP project the implications of a choice for a certain definition, additional compartments of the C cycle, and feasibility of monitoring are assessed for a limited number of countries. This is done by applying those definitions and additional measures to the countries` C budget on the latest data. The forest related matters are handled by the Institute for Forestry and Nature Research (IBN-DLO), the soil related matters are handled by the Research Institute for Agrobiology and Soil fertility (AB-DLO), the monitoring and verification matters are handled by the Winand Staring Centre for Integrated Land, Soil and Water Research (SC-DLO). 120 refs.

  2. Implementing an Oxygen Supplementation and Monitoring Protocol on Inpatient Pediatric Bronchiolitis: An Exercise in Deimplementation

    Directory of Open Access Journals (Sweden)

    Brian LeCleir

    2017-01-01

    Full Text Available Aim. Our goal in this study is to evaluate the effectiveness of our oxygen (O2 protocol to reduce length of stay (LOS for children hospitalized with bronchiolitis. Methods. In this retrospective cohort study, the outcomes of children ≤ 24 months old that were admitted with bronchiolitis and placed on the O2 protocol were compared to historical controls. The primary outcome was hospital length of stay. Secondary outcomes were duration of O2 supplementation, rates of pediatric intensive care unit transfer, and readmission. Results. Groups were not significantly different in age, gender, and rates of respiratory distress score assessment. Significantly more severely ill patients were in the O2 protocol group. There were no significant differences between control and O2 protocol groups with regard to mean LOS, rates of pediatric intensive care unit transfer, or seven-day readmission rates. By multiple regression analysis, the use of the O2 protocol was associated with a nearly 20% significant decrease in the length of hospitalization (p=0.030. Conclusion. Use of O2 supplementation protocol increased LOS in the more ill patients with bronchiolitis but decreased overall LOS by having a profound effect on patients with mild bronchiolitis.

  3. A Selected Reaction Monitoring Mass Spectrometry Protocol for Validation of Proteomic Biomarker Candidates in Studies of Psychiatric Disorders.

    Science.gov (United States)

    Reis-de-Oliveira, Guilherme; Garcia, Sheila; Guest, Paul C; Cassoli, Juliana S; Martins-de-Souza, Daniel

    2017-01-01

    Most biomarker candidates arising from proteomic studies of psychiatric disorders have not progressed for use in clinical studies due to insufficient validation steps. Here we describe a selective reaction monitoring mass spectrometry (SRM-MS) approach that could be used as a follow-up validation tool of proteins identified in blood serum or plasma. This protocol specifically covers the stages of peptide selection and optimization. The increasing application of SRM-MS should enable fast, sensitive, and robust methods with the potential for use in clinical studies involving sampling of serum or plasma. Understanding the molecular mechanisms and identifying potential biomarkers for risk assessment, diagnosis, prognosis, and prediction of drug response goes toward the implementation of translational medicine strategies for improved treatment of patients with psychiatric disorders and other debilitating diseases.

  4. Heterodyne Angle Deviation Interferometry in Vibration and Bubble Measurements

    OpenAIRE

    Ming-Hung Chiu; Jia-Ze Shen; Jian-Ming Huang

    2016-01-01

    We proposed heterodyne angle deviation interferometry (HADI) for angle deviation measurements. The phase shift of an angular sensor (which can be a metal film or a surface plasmon resonance (SPR) prism) is proportional to the deviation angle of the test beam. The method has been demonstrated in bubble and speaker’s vibration measurements in this paper. In the speaker’s vibration measurement, the voltage from the phase channel of a lock-in amplifier includes the vibration level and frequency. ...

  5. Ultra low power signal oriented approach for wireless health monitoring.

    Science.gov (United States)

    Marinkovic, Stevan; Popovici, Emanuel

    2012-01-01

    In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios.

  6. GLRT Based Anomaly Detection for Sensor Network Monitoring

    KAUST Repository

    Harrou, Fouzi

    2015-12-07

    Proper operation of antenna arrays requires continuously monitoring their performances. When a fault occurs in an antenna array, the radiation pattern changes and can significantly deviate from the desired design performance specifications. In this paper, the problem of fault detection in linear antenna arrays is addressed within a statistical framework. Specifically, a statistical fault detection method based on the generalized likelihood ratio (GLR) principle is utilized for detecting potential faults in linear antenna arrays. The proposed method relies on detecting deviations in the radiation pattern of the monitored array with respect to a reference (fault-free) one. To assess the abilities of the GLR based fault detection method, three case studies involving different types of faults have been performed. The simulation results clearly illustrate the effectiveness of the GLR-based fault detection method in monitoring the performance of linear antenna arrays.

  7. GLRT Based Anomaly Detection for Sensor Network Monitoring

    KAUST Repository

    Harrou, Fouzi; Sun, Ying

    2015-01-01

    Proper operation of antenna arrays requires continuously monitoring their performances. When a fault occurs in an antenna array, the radiation pattern changes and can significantly deviate from the desired design performance specifications. In this paper, the problem of fault detection in linear antenna arrays is addressed within a statistical framework. Specifically, a statistical fault detection method based on the generalized likelihood ratio (GLR) principle is utilized for detecting potential faults in linear antenna arrays. The proposed method relies on detecting deviations in the radiation pattern of the monitored array with respect to a reference (fault-free) one. To assess the abilities of the GLR based fault detection method, three case studies involving different types of faults have been performed. The simulation results clearly illustrate the effectiveness of the GLR-based fault detection method in monitoring the performance of linear antenna arrays.

  8. The effect of the introduction of a standard monitoring protocol on ...

    African Journals Online (AJOL)

    2011-03-07

    Mar 7, 2011 ... management protocol had had any effect on the metabolic and nonmetabolic .... Ages were not recorded. ..... of happiness and wealth.14 Three-quarters of the girls associated ... Information on lifestyle and advice to reduce.

  9. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    Energy Technology Data Exchange (ETDEWEB)

    Drzymala, R. E., E-mail: drzymala@wustl.edu [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Alvarez, P. E. [Imaging and Radiation Oncology Core Houston, UT MD Anderson Cancer Center, Houston, Texas 77030 (United States); Bednarz, G. [Radiation Oncology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15232 (United States); Bourland, J. D. [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina 27157 (United States); DeWerd, L. A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Ma, L. [Department of Radiation Oncology, University California San Francisco, San Francisco, California 94143 (United States); Meltsner, S. G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Neyman, G. [Department of Radiation Oncology, The Cleveland Clinic Foundation, Cleveland, Ohio 44195 (United States); Novotny, J. [Medical Physics Department, Hospital Na Homolce, Prague 15030 (Czech Republic); Petti, P. L. [Gamma Knife Center, Washington Hospital Healthcare System, Fremont, California 94538 (United States); Rivard, M. J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Shiu, A. S. [Department of Radiation Oncology, University of Southern California, Los Angeles, California 90033 (United States); Goetsch, S. J. [San Diego Medical Physics, Inc., La Jolla, California 92037 (United States)

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods: Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS

  10. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant.

    Science.gov (United States)

    Moreno-Garcia, Isabel M; Palacios-Garcia, Emilio J; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J; Varo-Martinez, Marta; Real-Calvo, Rafael J

    2016-05-26

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant's components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid.

  11. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant

    Science.gov (United States)

    Moreno-Garcia, Isabel M.; Palacios-Garcia, Emilio J.; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J.; Varo-Martinez, Marta; Real-Calvo, Rafael J.

    2016-01-01

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant’s components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid. PMID:27240365

  12. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant

    Directory of Open Access Journals (Sweden)

    Isabel M. Moreno-Garcia

    2016-05-01

    Full Text Available There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant’s components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid.

  13. EFFECT OF DIFFERENT STRETCHING PROTOCOLS ON VERTICAL JUMP PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Emre Serin

    2018-04-01

    Full Text Available This study aimed to examine the effect of different stretching exercises on vertical jump performance. A total of 14 national male athletes sporting in the elite level took part in the study. The age average of the participants was 20.25±1.03 year, the average height was 1.80±.08 m, the average body weight was 77.14±18.91 kg, average of sporting age was 9.87±3.31 year and the average number of participation in international games was 10.0±3.31. As stretching protocol: Method 1 (5 minutes of jogging and 2 minutes of active rest followed by Method 2 (static stretching for 4 different muscle groups 3 repetitions for 15 seconds of static stretching, rest for 10 seconds between groups and then consecutively, Method 3 (Dynamic stretching exercises with 3 repetitions for 15 seconds and 10 seconds rest between different muscle groups were applied in the study. The vertical jump performance before and after different stretching exercises of the participants was determined by means of the vertical jump test using the smart speed lite system. Before and after the training of all athletes, HR was recorded with a heart rate monitor (RS 800, Polar Vantage NV, Polar Electro Oy, Finland with 5 seconds intervals. Before the study, the chest band of the heartbeat monitor was placed on the chest of the athlete and the HR was recorded from the monitor. SPSS 15.0 statistical package program was used for evaluation and calculation of the data. In this study in addition to descriptive statistics (mean and standard deviation paired samples t-test was used to determine the difference between the vertical jump performance of the participants before and after different stretching exercises. As a result, this study showed that; applying the dynamic and static stretching exercises consecutively affected the vertical jump performance 4.5 cm positively (p<.05. It is suggested that different dynamic and static stretching exercises should be included in the vertical jump.

  14. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  15. [The crooked nose: correction of dorsal and caudal septal deviations].

    Science.gov (United States)

    Foda, H M T

    2010-09-01

    The deviated nose represents a complex cosmetic and functional problem. Septal surgery plays a central role in the successful management of the externally deviated nose. This study included 800 patients seeking rhinoplasty to correct external nasal deviations; 71% of these suffered from variable degrees of nasal obstruction. Septal surgery was necessary in 736 (92%) patients, not only to improve breathing, but also to achieve a straight, symmetric external nose. A graduated surgical approach was adopted to allow correction of the dorsal and caudal deviations of the nasal septum without weakening its structural support to the nasal dorsum or nasal tip. The approach depended on full mobilization of deviated cartilage, followed by straightening of the cartilage and its fixation in the corrected position by using bony splinting grafts through an external rhinoplasty approach.

  16. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  17. Improving metabolic monitoring in patients maintained on antipsychotics in Penang, Malaysia.

    Science.gov (United States)

    Hor, Esther Sl; Subramaniam, Sivasangari; Koay, Jun Min; Bharathy, Arokiamary; Vasudevan, Umadevi; Panickulam, Joseph J; Ng, InnTiong; Arif, Nor Hayati; Russell, Vincent

    2016-02-01

    To evaluate the monitoring of metabolic parameters among outpatients maintained on antipsychotic medications in a general hospital setting in Malaysia and to assess the impact of a local monitoring protocol. By performing a baseline audit of files from a random sample of 300 patients prescribed antipsychotic medications for at least 1 year; we determined the frequency of metabolic monitoring. The findings informed the design of a new local protocol, on which clinical staff was briefed. We re-evaluated metabolic monitoring immediately after implementation, in a small sample of new referrals and current patients. We explored staff perceptions of the initiative with a follow-up focus group, 6 months post-implementation. The baseline audit revealed a sub-optimal frequency of metabolic parameter recording. Re-audit, following implementation of the new protocol, revealed improved monitoring but persisting deficits. Dialogue with the clinical staff led to further protocol modification, clearer definition of staff roles and use of a standard recording template. Focus group findings revealed positive perceptions of the initiative, but persisting implementation barriers, including cultural issues surrounding waist circumference measurement. Responding to challenges in achieving improved routine metabolic monitoring of patients maintained on antipsychotics required on-going dialogue with the clinical staff, in order to address both service pressures and cultural concerns. © The Royal Australian and New Zealand College of Psychiatrists 2015.

  18. Statistical monitoring of linear antenna arrays

    KAUST Repository

    Harrou, Fouzi; Sun, Ying

    2016-01-01

    The paper concerns the problem of monitoring linear antenna arrays using the generalized likelihood ratio (GLR) test. When an abnormal event (fault) affects an array of antenna elements, the radiation pattern changes and significant deviation from

  19. Morphologic changes of the anal sphincter musculature during and after temporary stool deviation.

    Science.gov (United States)

    Sailer, M; Fein, M; Fuchs, K H; Bussen, D; Grun, C; Thiede, A

    2001-04-01

    Temporary stool deviation, using a stoma, is a well-known surgical principle to protect low colorectal or coloanal anastomoses. The purpose of this study was to evaluate any morphologic changes with regard to the anal sphincter muscles during and after temporary ileostomy. Forty-four patients with rectal carcinomas were studied prospectively. All patients underwent low anterior resection. Reconstruction was performed using either a coloanal pouch or a straight end-to-end anastomosis. A protective stoma was fashioned in all 44 patients (ileostomy n=41; colostomy n=3). Stoma closure was carried out after a median of 85 days (41-330 days). Using a standard protocol, anal-sphincter thickness [m. puborectalis, external anal sphincter (EAS) and internal anal (IAS) sphincter] was assessed by means of endoanal ultrasonography preoperatively, at the time of stoma closure, and every 3 months thereafter for 1 year. The diameter of the puborectal muscle decreased from a median preoperative value of 6.3 mm to 5.7 mm at the time of stoma closure (P=0.03). After 3 months, 6.2 mm was measured. This value remained stable for the complete follow-up period. Similar results were recorded for the EAS. The IAS thickness remained stable throughout the study period, measuring between 2.1 mm and 2.4 mm. Temporary stool deviation does lead to morphologic changes of the anal sphincter. While the smooth muscle remains unchanged, the striated counterpart undergoes atrophic transformation. However, after passage reconstruction, i.e., stoma closure, a rapid regeneration of the voluntary muscles is observed.

  20. A software defined RTU multi-protocol automatic adaptation data transmission method

    Science.gov (United States)

    Jin, Huiying; Xu, Xingwu; Wang, Zhanfeng; Ma, Weijun; Li, Sheng; Su, Yong; Pan, Yunpeng

    2018-02-01

    Remote terminal unit (RTU) is the core device of the monitor system in hydrology and water resources. Different devices often have different communication protocols in the application layer, which results in the difficulty in information analysis and communication networking. Therefore, we introduced the idea of software defined hardware, and abstracted the common feature of mainstream communication protocols of RTU application layer, and proposed a uniformed common protocol model. Then, various communication protocol algorithms of application layer are modularized according to the model. The executable codes of these algorithms are labeled by the virtual functions and stored in the flash chips of embedded CPU to form the protocol stack. According to the configuration commands to initialize the RTU communication systems, it is able to achieve dynamic assembling and loading of various application layer communication protocols of RTU and complete the efficient transport of sensor data from RTU to central station when the data acquisition protocol of sensors and various external communication terminals remain unchanged.

  1. Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Hammel, Gertrud; Bramlage, Peter

    2017-05-01

    The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: • Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. • The majority of devices has not been validated in children. What is New: • Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). • The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.

  2. Deviation of a Jet at a T junction at low Reynolds number

    Science.gov (United States)

    Panizza, Pascal; Engl, Wilfried; Ohata, Kouske; Colin, Annie

    2006-03-01

    We study the hydrodynamic behaviour of a laminar jet flowing through a channel when it reaches a junction. We observe the existence of two possible flow regimes, namely the splitting and deviation of a jet in the most simple microfluidic configuration, namely a T junction. The transition between the two regimes is not monitored by the shape of the T junction nor by capillary effects, but can be easily anticipated in terms of the hydrodynamic properties of the flow. We present a simple hydrodynamic model which is in very good agreement with observed experimental jet behaviour. The transition between both regime acts as a flow or viscosity comparator. We show how this effect can be used for the design of digital and integrated microfluidic devices

  3. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  4. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    Science.gov (United States)

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  5. Remote Sensing and the Kyoto Protocol: A Workshop Summary

    Science.gov (United States)

    Rosenqvist, Ake; Imhoff, Marc; Milne, Anthony; Dobson, Craig

    2000-01-01

    The Kyoto Protocol to the United Nations Framework Convention on Climate Change contains quantified, legally binding commitments to limit or reduce greenhouse gas emissions to 1990 levels and allows carbon emissions to be balanced by carbon sinks represented by vegetation. The issue of using vegetation cover as an emission offset raises a debate about the adequacy of current remote sensing systems and data archives to both assess carbon stocks/sinks at 1990 levels, and monitor the current and future global status of those stocks. These concerns and the potential ratification of the Protocol among participating countries is stimulating policy debates and underscoring a need for the exchange of information between the international legal community and the remote sensing community. On October 20-22 1999, two working groups of the International Society for Photogrammetry and Remote Sensing (ISPRS) joined with the University of Michigan (Michigan, USA) to convene discussions on how remote sensing technology could contribute to the information requirements raised by implementation of, and compliance with, the Kyoto Protocol. The meeting originated as a joint effort between the Global Monitoring Working Group and the Radar Applications Working Group in Commission VII of the ISPRS, co-sponsored by the University of Michigan. Tile meeting was attended by representatives from national government agencies and international organizations and academic institutions. Some of the key themes addressed were: (1) legal aspects of transnational remote sensing in the context of the Kyoto Protocol; (2) a review of the current and future and remote sensing technologies that could be applied to the Kyoto Protocol; (3) identification of areas where additional research is needed in order to advance and align remote sensing technology with the requirements and expectations of the Protocol; and 94) the bureaucratic and research management approaches needed to align the remote sensing

  6. Complexity analysis based on generalized deviation for financial markets

    Science.gov (United States)

    Li, Chao; Shang, Pengjian

    2018-03-01

    In this paper, a new modified method is proposed as a measure to investigate the correlation between past price and future volatility for financial time series, known as the complexity analysis based on generalized deviation. In comparison with the former retarded volatility model, the new approach is both simple and computationally efficient. The method based on the generalized deviation function presents us an exhaustive way showing the quantization of the financial market rules. Robustness of this method is verified by numerical experiments with both artificial and financial time series. Results show that the generalized deviation complexity analysis method not only identifies the volatility of financial time series, but provides a comprehensive way distinguishing the different characteristics between stock indices and individual stocks. Exponential functions can be used to successfully fit the volatility curves and quantify the changes of complexity for stock market data. Then we study the influence for negative domain of deviation coefficient and differences during the volatile periods and calm periods. after the data analysis of the experimental model, we found that the generalized deviation model has definite advantages in exploring the relationship between the historical returns and future volatility.

  7. Analysis of Security Protocols for Mobile Healthcare.

    Science.gov (United States)

    Wazid, Mohammad; Zeadally, Sherali; Das, Ashok Kumar; Odelu, Vanga

    2016-11-01

    Mobile Healthcare (mHealth) continues to improve because of significant improvements and the decreasing costs of Information Communication Technologies (ICTs). mHealth is a medical and public health practice, which is supported by mobile devices (for example, smartphones) and, patient monitoring devices (for example, various types of wearable sensors, etc.). An mHealth system enables healthcare experts and professionals to have ubiquitous access to a patient's health data along with providing any ongoing medical treatment at any time, any place, and from any device. It also helps the patient requiring continuous medical monitoring to stay in touch with the appropriate medical staff and healthcare experts remotely. Thus, mHealth has become a major driving force in improving the health of citizens today. First, we discuss the security requirements, issues and threats to the mHealth system. We then present a taxonomy of recently proposed security protocols for mHealth system based on features supported and possible attacks, computation cost and communication cost. Our detailed taxonomy demonstrates the strength and weaknesses of recently proposed security protocols for the mHealth system. Finally, we identify some of the challenges in the area of security protocols for mHealth systems that still need to be addressed in the future to enable cost-effective, secure and robust mHealth systems.

  8. Supportive Mental Health Self-Monitoring among Smartphone Users with Psychological Distress: Protocol for a Fully Mobile Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Till Beiwinkel

    2017-09-01

    Full Text Available Mobile health (mHealth could be widely used in the population to improve access to psychological treatment. In this paper, we describe the development of a mHealth intervention on the basis of supportive self-monitoring and describe the protocol for a randomized controlled trial to evaluate its effectiveness among smartphone users with psychological distress. Based on power analysis, a representative quota sample of N = 186 smartphone users will be recruited, with an over-sampling of persons with moderate to high distress. Over a 4-week period, the intervention will be compared to a self-monitoring without intervention group and a passive control group. Telephone interviews will be conducted at baseline, post-intervention (4 weeks, and 12-week follow-up to assess study outcomes. The primary outcome will be improvement of mental health. Secondary outcomes will include well-being, intentions toward help-seeking and help-seeking behavior, user activation, attitudes toward mental-health services, perceived stigmatization, smartphone app quality, user satisfaction, engagement, and adherence with the intervention. Additionally, data from the user’s daily life as collected during self-monitoring will be used to investigate risk and protective factors of mental health in real-world settings. Therefore, this study will allow us to demonstrate the effectiveness of a smartphone application as a widely accessible and low-cost intervention to improve mental health on a population level. It also allows to identify new assessment approaches in the field of psychiatric epidemiology.

  9. Supportive Mental Health Self-Monitoring among Smartphone Users with Psychological Distress: Protocol for a Fully Mobile Randomized Controlled Trial

    Science.gov (United States)

    Beiwinkel, Till; Hey, Stefan; Bock, Olaf; Rössler, Wulf

    2017-01-01

    Mobile health (mHealth) could be widely used in the population to improve access to psychological treatment. In this paper, we describe the development of a mHealth intervention on the basis of supportive self-monitoring and describe the protocol for a randomized controlled trial to evaluate its effectiveness among smartphone users with psychological distress. Based on power analysis, a representative quota sample of N = 186 smartphone users will be recruited, with an over-sampling of persons with moderate to high distress. Over a 4-week period, the intervention will be compared to a self-monitoring without intervention group and a passive control group. Telephone interviews will be conducted at baseline, post-intervention (4 weeks), and 12-week follow-up to assess study outcomes. The primary outcome will be improvement of mental health. Secondary outcomes will include well-being, intentions toward help-seeking and help-seeking behavior, user activation, attitudes toward mental-health services, perceived stigmatization, smartphone app quality, user satisfaction, engagement, and adherence with the intervention. Additionally, data from the user’s daily life as collected during self-monitoring will be used to investigate risk and protective factors of mental health in real-world settings. Therefore, this study will allow us to demonstrate the effectiveness of a smartphone application as a widely accessible and low-cost intervention to improve mental health on a population level. It also allows to identify new assessment approaches in the field of psychiatric epidemiology. PMID:28983477

  10. Supportive Mental Health Self-Monitoring among Smartphone Users with Psychological Distress: Protocol for a Fully Mobile Randomized Controlled Trial.

    Science.gov (United States)

    Beiwinkel, Till; Hey, Stefan; Bock, Olaf; Rössler, Wulf

    2017-01-01

    Mobile health (mHealth) could be widely used in the population to improve access to psychological treatment. In this paper, we describe the development of a mHealth intervention on the basis of supportive self-monitoring and describe the protocol for a randomized controlled trial to evaluate its effectiveness among smartphone users with psychological distress. Based on power analysis, a representative quota sample of N  = 186 smartphone users will be recruited, with an over-sampling of persons with moderate to high distress. Over a 4-week period, the intervention will be compared to a self-monitoring without intervention group and a passive control group. Telephone interviews will be conducted at baseline, post-intervention (4 weeks), and 12-week follow-up to assess study outcomes. The primary outcome will be improvement of mental health. Secondary outcomes will include well-being, intentions toward help-seeking and help-seeking behavior, user activation, attitudes toward mental-health services, perceived stigmatization, smartphone app quality, user satisfaction, engagement, and adherence with the intervention. Additionally, data from the user's daily life as collected during self-monitoring will be used to investigate risk and protective factors of mental health in real-world settings. Therefore, this study will allow us to demonstrate the effectiveness of a smartphone application as a widely accessible and low-cost intervention to improve mental health on a population level. It also allows to identify new assessment approaches in the field of psychiatric epidemiology.

  11. Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2: 2013 protocols.

    Science.gov (United States)

    Bing, Sen; Chen, Kang; Hou, Hong; Zhang, Weijuan; Li, Linyi; Wei, Jiao; Shu, Chang; Wan, Yi

    2016-04-01

    This study aimed to determine the accuracy of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors according to the European Society of Hypertension International Protocol revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols. The devices were assessed on 33 participants according to the European Society of Hypertension requirements and were then tested on 85 participants according to the ANSI/AAMI/ISO 81060-2:2013 criteria. Procedures and data analysis were carried out following protocol guidelines precisely. The Microlife BP A200 Comfort and W2 Slim devices passed the criteria of the European Society of Hypertension International Protocol revision 2010 for both systolic blood pressure and diastolic blood pressure. The devices also fulfilled the ANSI/AAMI/ISO 81060-2:2013 criteria, with mean differences of SBP and DPB between the devices and observers of 0.38±5.12 and 0.28±4.29 mmHg for the BP A200 Comfort and 1.01±6.80 and 0.34±5.62 mmHg for the W2 Slim, respectively. The Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors fulfilled the European Society of Hypertension revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols, and can be recommended for self-measurement in the general population.

  12. Deviation equation in spaces with affine connection. Pts. 3 and 4

    International Nuclear Information System (INIS)

    Iliev, B.Z.

    1987-01-01

    The concept of a parallel transport is used to define a class of displacement vectors in spaces with affine connection. The nonlocal deviation equation in such spaces is introduced using a definition of the deviation vector based on the displacement vector. It turns out to be a special of the generalized deviation equation, but having an appropriate physical interpretation. The equation of geodesic deviation is presented as an example

  13. Urban Adolescents Readily Comply with a Complicated Asthma Research Protocol

    Directory of Open Access Journals (Sweden)

    Stephanie Lovinsky-Desir

    2014-01-01

    Full Text Available Purpose Adolescents are often cited as having poor rates of compliance with medical regimens and research protocols. We quantified compliance in a cohort of urban adolescents participating in a complex research protocol in which measures were obtained without direct supervision by research personnel. Methods A total of 54 early adolescents ages 10-13 were asked to wear a vest containing a personal air pollutant exposure monitor for two 24-hour periods and to perform daily peak expiratory flow (PEF for six consecutive days. Compliance with wearing the vest was measured by comparing accelerometer data from a device within the vest to one worn continuously on the child's wrist. Daily PEF data were recorded using an electronic meter. Results A priori definition of compliance was met by 85% of the adolescents by wearing the exposure monitoring vest and 72% by performing PEF. Conclusions These findings suggest that early adolescents can be compliant with complex research protocols that are needed to help bridge gaps in pediatric asthma research.

  14. Influence of asymmetrical drawing radius deviation in micro deep drawing

    Science.gov (United States)

    Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.

    2017-09-01

    Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.

  15. Two and three dimensional core power distribution monitor and display

    International Nuclear Information System (INIS)

    Impink, A.J. Jr.; Grobmyer, L.R.

    1988-01-01

    This patent describes a sensor monitoring system for displaying a profile of fractional deviations in relative coolant enthalpy rise over a defined area comprising at least a part of a core of a nuclear reactor, which system comprises: core exit coolant temperature sensors positioned to monitor at least a portion of the defined area; an inlet temperature sensor outside the core which monitors the temperature of core coolant at an inlet to the reactor means, responsive to the outputs from both the core exit temperature sensors and the inlet temperature sensor, for generating corresponding representative values of actual coolant enthalpy rise and corresponding values of relative enthalpy rise at each location in the defined area at which a core exit coolant temperature sensor is available; means, responsive to the generated values of relative enthalpy rise and to reference values of relative enthalpy rise at corresponding locations in the defined area, for generating values of the fractional deviation of the measured values of relative enthalpy rise from the corresponding values; means for interpolating the generated values of fractional deviation in relative enthalpy rise to provide interpolated values of fractional deviation in relative enthalpy rise at locations in the defined area of the core other than those at which core exit coolant temperature sensors are available; and means for multidimensionally displaying the generated and interpolated values

  16. Limiting values of large deviation probabilities of quadratic statistics

    NARCIS (Netherlands)

    Jeurnink, Gerardus A.M.; Kallenberg, W.C.M.

    1990-01-01

    Application of exact Bahadur efficiencies in testing theory or exact inaccuracy rates in estimation theory needs evaluation of large deviation probabilities. Because of the complexity of the expressions, frequently a local limit of the nonlocal measure is considered. Local limits of large deviation

  17. Refraction in Terms of the Deviation of the Light.

    Science.gov (United States)

    Goldberg, Fred M.

    1985-01-01

    Discusses refraction in terms of the deviation of light. Points out that in physics courses where very little mathematics is used, it might be more suitable to describe refraction entirely in terms of the deviation, rather than by introducing Snell's law. (DH)

  18. Survey is based on Synchronized and Asynchronized Approach of MAC Protocols in WSN

    Directory of Open Access Journals (Sweden)

    Soni Chaurasia

    2010-07-01

    Full Text Available A wireless network is made of spatially distributed autonomous devices. These devices are called sensors. The sensor is used for monitoring physical or environmental conditions. The potential application of wireless sensor network is environmental monitoring, healthcare applications and tactical systems. In this paper focus is on the MAC protocol for WSN. Wireless sensor network is deployed for wide range to send and receive data with the help of medium. Here literature survey of MAC protocol based on the synchronized and asynchronized approach is described which is used to meet different objective like access a medium, statistical channel allocation, spectrum utilization

  19. Mean-deviation analysis in the theory of choice.

    Science.gov (United States)

    Grechuk, Bogdan; Molyboha, Anton; Zabarankin, Michael

    2012-08-01

    Mean-deviation analysis, along with the existing theories of coherent risk measures and dual utility, is examined in the context of the theory of choice under uncertainty, which studies rational preference relations for random outcomes based on different sets of axioms such as transitivity, monotonicity, continuity, etc. An axiomatic foundation of the theory of coherent risk measures is obtained as a relaxation of the axioms of the dual utility theory, and a further relaxation of the axioms are shown to lead to the mean-deviation analysis. Paradoxes arising from the sets of axioms corresponding to these theories and their possible resolutions are discussed, and application of the mean-deviation analysis to optimal risk sharing and portfolio selection in the context of rational choice is considered. © 2012 Society for Risk Analysis.

  20. Security of Semi-Device-Independent Random Number Expansion Protocols.

    Science.gov (United States)

    Li, Dan-Dan; Wen, Qiao-Yan; Wang, Yu-Kun; Zhou, Yu-Qian; Gao, Fei

    2015-10-27

    Semi-device-independent random number expansion (SDI-RNE) protocols require some truly random numbers to generate fresh ones, with making no assumptions on the internal working of quantum devices except for the dimension of the Hilbert space. The generated randomness is certified by non-classical correlation in the prepare-and-measure test. Until now, the analytical relations between the amount of the generated randomness and the degree of non-classical correlation, which are crucial for evaluating the security of SDI-RNE protocols, are not clear under both the ideal condition and the practical one. In the paper, first, we give the analytical relation between the above two factors under the ideal condition. As well, we derive the analytical relation under the practical conditions, where devices' behavior is not independent and identical in each round and there exists deviation in estimating the non-classical behavior of devices. Furthermore, we choose a different randomness extractor (i.e., two-universal random function) and give the security proof.

  1. Illusory shadow person causing paradoxical gaze deviations during temporal lobe seizures

    NARCIS (Netherlands)

    Zijlmans, M.; van Eijsden, P.; Ferrier, C. H.; Kho, K. H.; van Rijen, P. C.; Leijten, F. S. S.

    Generally, activation of the frontal eye field during seizures can cause versive (forced) gaze deviation, while non-versive head deviation is hypothesised to result from ictal neglect after inactivation of the ipsilateral temporoparietal area. Almost all non-versive head deviations occurring during

  2. Dose Specification and Quality Assurance of Radiation Therapy Oncology Group Protocol 95-17; a Cooperative Group Study of Iridium-192 Breast Implants as Sole Therapy

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S.; Hanson, W.F.; O'Meara, Elizabeth; Kuske, Robert R.; Arthur, Douglas; Rabinovitch, Rachel; White, Julia; Wilenzick, Raymond M.; Harris, Irene; Tailor, Ramesh C.

    2007-01-01

    Purpose: The Radiation Therapy Oncology Group (RTOG) protocol 95-17 was a Phase I/II trial to evaluate multicatheter brachytherapy as the sole method of adjuvant breast radiotherapy for Stage I/II breast carcinoma after breast-conserving surgery. Low- or high-dose-rate sources were allowed. Dose prescription and treatment evaluation were based on recommendations in the International Commission on Radiation Units and Measurements (ICRU), Report 58 and included the parameters mean central dose (MCD), average peripheral dose, dose homogeneity index (DHI), and the dimensions of the low- and high-dose regions. Methods and Materials: Three levels of quality assurance were implemented: (1) credentialing of institutions was required before entering patients into the study; (2) rapid review of each treatment plan was conducted before treatment; and (3) retrospective review was performed by the Radiological Physics Center in conjunction with the study chairman and RTOG dosimetry staff. Results: Credentialing focused on the accuracy of dose calculation algorithm and compliance with protocol guidelines. Rapid review was designed to identify and correct deviations from the protocol before treatment. The retrospective review involved recalculation of dosimetry parameters and review of dose distributions to evaluate the treatment. Specifying both central and peripheral doses resulted in uniform dose distributions, with a mean dose homogeneity index of 0.83 ± 0.06. Conclusions: Vigorous quality assurance resulted in a high-quality study with few deviations; only 4 of 100 patients were judged as representing minor variations from protocol, and no patient was judged as representing major deviation. This study should be considered a model for quality assurance of future trials

  3. A New Mechanism for Network Monitoring and Shielding in Wireless LAN

    Directory of Open Access Journals (Sweden)

    Jiujun Cheng

    2014-01-01

    Full Text Available Wireless LAN (WLAN technology is developing rapidly with the help of wireless communication technology and social demand. During the development of WLAN, the security is more and more important, and wireless monitoring and shielding are of prime importance for network security. In this paper, we have explored various security issues of IEEE 802.11 based wireless network and analyzed numerous problems in implementing the wireless monitoring and shielding system. We identify the challenges which monitoring and shielding system needs to be aware of, and then provide a feasible mechanism to avoid those challenges. We implemented an actual wireless LAN monitoring and shielding system on Maemo operating system to monitor wireless network data stream efficiently and solve the security problems of mobile users. More importantly, the system analyzes wireless network protocols efficiently and flexibly, reveals rich information of the IEEE 802.11 protocol such as traffic distribution and different IP connections, and graphically displays later. Moreover, the system running results show that the system has the capability to work stably, and accurately and analyze the wireless protocols efficiently.

  4. Deviations from Newton's law in supersymmetric large extra dimensions

    International Nuclear Information System (INIS)

    Callin, P.; Burgess, C.P.

    2006-01-01

    Deviations from Newton's inverse-squared law at the micron length scale are smoking-gun signals for models containing supersymmetric large extra dimensions (SLEDs), which have been proposed as approaches for resolving the cosmological constant problem. Just like their non-supersymmetric counterparts, SLED models predict gravity to deviate from the inverse-square law because of the advent of new dimensions at sub-millimeter scales. However SLED models differ from their non-supersymmetric counterparts in three important ways: (i) the size of the extra dimensions is fixed by the observed value of the dark energy density, making it impossible to shorten the range over which new deviations from Newton's law must be seen; (ii) supersymmetry predicts there to be more fields in the extra dimensions than just gravity, implying different types of couplings to matter and the possibility of repulsive as well as attractive interactions; and (iii) the same mechanism which is purported to keep the cosmological constant naturally small also keeps the extra-dimensional moduli effectively massless, leading to deviations from general relativity in the far infrared of the scalar-tensor form. We here explore the deviations from Newton's law which are predicted over micron distances, and show the ways in which they differ and resemble those in the non-supersymmetric case

  5. Performance of Phonatory Deviation Diagrams in Synthesized Voice Analysis.

    Science.gov (United States)

    Lopes, Leonardo Wanderley; da Silva, Karoline Evangelista; da Silva Evangelista, Deyverson; Almeida, Anna Alice; Silva, Priscila Oliveira Costa; Lucero, Jorge; Behlau, Mara

    2018-05-02

    To analyze the performance of a phonatory deviation diagram (PDD) in discriminating the presence and severity of voice deviation and the predominant voice quality of synthesized voices. A speech-language pathologist performed the auditory-perceptual analysis of the synthesized voice (n = 871). The PDD distribution of voice signals was analyzed according to area, quadrant, shape, and density. Differences in signal distribution regarding the PDD area and quadrant were detected when differentiating the signals with and without voice deviation and with different predominant voice quality. Differences in signal distribution were found in all PDD parameters as a function of the severity of voice disorder. The PDD area and quadrant can differentiate normal voices from deviant synthesized voices. There are differences in signal distribution in PDD area and quadrant as a function of the severity of voice disorder and the predominant voice quality. However, the PDD area and quadrant do not differentiate the signals as a function of severity of voice disorder and differentiated only the breathy and rough voices from the normal and strained voices. PDD density is able to differentiate only signals with moderate and severe deviation. PDD shape shows differences between signals with different severities of voice deviation. © 2018 S. Karger AG, Basel.

  6. Generation of deviation parameters for amino acid singlets, doublets ...

    Indian Academy of Sciences (India)

    We present a new method, secondary structure prediction by deviation parameter (SSPDP) for predicting the secondary structure of proteins from amino acid sequence. Deviation parameters (DP) for amino acid singlets, doublets and triplets were computed with respect to secondary structural elements of proteins based on ...

  7. VAR Portfolio Optimal: Perbandingan Antara Metode Markowitz dan Mean Absolute Deviation

    Directory of Open Access Journals (Sweden)

    R. Agus Sartono

    2009-05-01

    Full Text Available Portfolio selection method which have been introduced by Harry Markowitz (1952 used variance or deviation standard as a measure of risk. Kanno and Yamazaki (1991 introduced another method and used mean absolute deviation as a measure of risk instead of variance. The Value-at Risk (VaR is a relatively new method to capitalized risk that been used by financial institutions. The aim of this research is compare between mean variance and mean absolute deviation of two portfolios. Next, we attempt to assess the VaR of two portfolios using delta normal method and historical simulation. We use the secondary data from the Jakarta Stock Exchange – LQ45 during 2003. We find that there is a weak-positive correlation between deviation standard and return in both portfolios. The VaR nolmal delta based on mean absolute deviation method eventually is higher than the VaR normal delta based on mean variance method. However, based on the historical simulation the VaR of two methods is statistically insignificant. Thus, the deviation standard is sufficient measures of portfolio risk.Keywords: optimalisasi portofolio, mean-variance, mean-absolute deviation, value-at-risk, metode delta normal, metode simulasi historis

  8. Importance sampling large deviations in nonequilibrium steady states. I

    Science.gov (United States)

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T.

    2018-03-01

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  9. Importance sampling large deviations in nonequilibrium steady states. I.

    Science.gov (United States)

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T

    2018-03-28

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  10. Validation of the Beurer BM 44 upper arm blood pressure monitor for home measurement, according to the European Society of Hypertension International Protocol 2002.

    Science.gov (United States)

    Lüders, Stephan; Krüger, Ralf; Zemmrich, Claudia; Forstner, Klaus; Sturm, Claus-Dieter; Bramlage, Peter

    2012-12-01

    The present study aimed to validate the automated upper arm blood pressure (BP) measuring device BM 44 for home BP monitoring according to the 2002 Protocol of the European Society of Hypertension. The most important new feature of the new device was an integrated 'WHO indicator', which categorizes the patient's individual result within the WHO recommendations for target BP by a coloured scale. Systolic and diastolic BPs were measured sequentially in 35 adult participants (16 men, 19 women) using a standard mercury y-tubed reference sphygmomanometer (two observers) and the BM 44 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. The BM 44 device passed phase 1 of the validation study successfully with a number of absolute differences between device and observers of 5, 10 and 15 mmHg for at least 28 out of 25, 35 out of 35 and 40 out of 40 measurements, respectively. The device also achieved the targets for phases 2.1 and 2.2, with 23 and 26 participants having had at least two of three device-observers differences within 5 mmHg for systolic and diastolic BP, respectively. The Beurer BM 44 upper arm BP monitor has passed the International Protocol requirements, and hence can be recommended for home use in adults. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  11. Standard Deviation for Small Samples

    Science.gov (United States)

    Joarder, Anwar H.; Latif, Raja M.

    2006-01-01

    Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…

  12. The deviation matrix of a continuous-time Markov chain

    NARCIS (Netherlands)

    Coolen-Schrijner, P.; van Doorn, E.A.

    2001-01-01

    The deviation matrix of an ergodic, continuous-time Markov chain with transition probability matrix $P(.)$ and ergodic matrix $\\Pi$ is the matrix $D \\equiv \\int_0^{\\infty} (P(t)-\\Pi)dt$. We give conditions for $D$ to exist and discuss properties and a representation of $D$. The deviation matrix of a

  13. The deviation matrix of a continuous-time Markov chain

    NARCIS (Netherlands)

    Coolen-Schrijner, Pauline; van Doorn, Erik A.

    2002-01-01

    he deviation matrix of an ergodic, continuous-time Markov chain with transition probability matrix $P(.)$ and ergodic matrix $\\Pi$ is the matrix $D \\equiv \\int_0^{\\infty} (P(t)-\\Pi)dt$. We give conditions for $D$ to exist and discuss properties and a representation of $D$. The deviation matrix of a

  14. Monitoring systems and their effectiveness for project cost control in construction

    NARCIS (Netherlands)

    Al-Jibouri, Saad H.S.

    2003-01-01

    This paper reports on a research to investigate the effectiveness of some commonly used monitoring systems, in detecting deviations from the planned cost and performance. The monitoring systems used in this work are: Leading parameter technique Variances method Activity based ratios technique The

  15. 45 CFR 63.19 - Budget revisions and minor deviations.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Budget revisions and minor deviations. 63.19 Section 63.19 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION GRANT PROGRAMS... Budget revisions and minor deviations. Pursuant to § 74.102(d) of this title, paragraphs (b)(3) and (b)(4...

  16. [Prediction of cardiac function deviations (ECG data) in the course of permanent cosmonaut's monitoring starting from selection till return to earth after short-duration space flight].

    Science.gov (United States)

    Kotovskaia, A R; Koloteva, M I; Luk'ianiuk, V Iu; Stepanova, G P; Filatova, L M; Buĭlov, S P; Zhernavkov, A F; Kondratiuk, L L

    2007-01-01

    Analyzed were deviations in cardiac function in 29 cosmonauts with previous aviation and other occupations ranging of 29 to 61 y.o. who made 8- to 30-day space flights (totai number of flights = 34) between 1982 and 2006. The deviations were identified in ECG records collected during clinical selection, clinical physiological examination (CPE) before flight, insertion and deorbit in transport vehicles, and post-flight CPE. Based on the analysis, the cosmonauts were distributed into three groups. The first group (55.2% of the cosmonauts) did not exhibit noticeable shifts and unfavorable trends in ECG at any time of the period of observation. The second group (34.5%) showed some deviations during selection and pre-flight CPE that became more apparent in the period of deorbit and were still present in post-flight ECG records. The third group (10.3%) displayed health-threatening deviations in cardiac function during deorbit. These findings give start to important investigations with the purpose to define permissible medical risks and ensuing establishment and perfection of medical criteria for candidates to cosmonauts with certain health problems.

  17. The role of septal surgery in management of the deviated nose.

    Science.gov (United States)

    Foda, Hossam M T

    2005-02-01

    The deviated nose represents a complex cosmetic and functional problem. Septal surgery plays a central role in the successful management of the externally deviated nose. This study included 260 patients seeking rhinoplasty to correct external nasal deviations; 75 percent of them had various degrees of nasal obstruction. Septal surgery was necessary in 232 patients (89 percent), not only to improve breathing but also to achieve a straight, symmetrical, external nose as well. A graduated surgical approach was adopted to allow correction of the dorsal and caudal deviations of the nasal septum without weakening its structural support to the dorsum or nasal tip. The approach depended on full mobilization of deviated cartilage, followed by straightening of the cartilage and its fixation in the corrected position by using bony splinting grafts through an external rhinoplasty approach.

  18. Long Term Resource Monitoring Program procedures: fish monitoring

    Science.gov (United States)

    Ratcliff, Eric N.; Glittinger, Eric J.; O'Hara, T. Matt; Ickes, Brian S.

    2014-01-01

    This manual constitutes the second revision of the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration-Environmental Management Program (UMRR-EMP) Long Term Resource Monitoring Program (LTRMP) element Fish Procedures Manual. The original (1988) manual merged and expanded on ideas and recommendations related to Upper Mississippi River fish sampling presented in several early documents. The first revision to the manual was made in 1995 reflecting important protocol changes, such as the adoption of a stratified random sampling design. The 1995 procedures manual has been an important document through the years and has been cited in many reports and scientific manuscripts. The resulting data collected by the LTRMP fish component represent the largest dataset on fish within the Upper Mississippi River System (UMRS) with more than 44,000 collections of approximately 5.7 million fish. The goal of this revision of the procedures manual is to document changes in LTRMP fish sampling procedures since 1995. Refinements to sampling methods become necessary as monitoring programs mature. Possible refinements are identified through field experiences (e.g., sampling techniques and safety protocols), data analysis (e.g., planned and studied gear efficiencies and reallocations of effort), and technological advances (e.g., electronic data entry). Other changes may be required because of financial necessity (i.e., unplanned effort reductions). This version of the LTRMP fish monitoring manual describes the most current (2014) procedures of the LTRMP fish component.

  19. Note onset deviations as musical piece signatures.

    Science.gov (United States)

    Serrà, Joan; Özaslan, Tan Hakan; Arcos, Josep Lluis

    2013-01-01

    A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  20. Note onset deviations as musical piece signatures.

    Directory of Open Access Journals (Sweden)

    Joan Serrà

    Full Text Available A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  1. Validation of the Omron HEM-7201 upper arm blood pressure monitor, for self-measurement in a high-altitude environment, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Cho, K; Tian, M; Lan, Y; Zhao, X; Yan, L L

    2013-08-01

    Few studies have been conducted on blood pressure monitors and their use at high altitude. This study is the first to evaluate the accuracy of an automatic blood pressure monitor in a high-altitude environment following a standard validation protocol. The Omron HEM-7201 upper arm blood pressure monitor was tested for accuracy in Lhasa, Tibet, China (3650 m above sea level) according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2). Thirty-three participants received 9-10 sequential blood pressure measurements alternating between a mercury sphygmomanometer and the device. The mean device-observer measurement difference was 1.0±5.9 mm Hg for systolic blood pressure (SBP) and -3.1±4.6 mm Hg for diastolic blood pressure (DBP). Of the 99 measurement pairs analyzed, 72, 90 and 97 device readings were within 5, 10 and 15 mm Hg, respectively, of the observer measurements for SBP, and 68, 92 and 99 readings for DBP. The number of participants with at least two out of three measurements within 5 mm Hg was 27 for SBP and 25 for DBP. Three participants had no measurements within 5 mm Hg for either SBP or DBP. As a result, the Omron HEM-7201 passes the ESH-IP2 validation criteria and can therefore be recommended for use in adults in this setting.

  2. An Analysis of the Linguistic Deviation in Chapter X of Oliver Twist

    Institute of Scientific and Technical Information of China (English)

    刘聪

    2013-01-01

    Charles Dickens is one of the greatest critical realist writers of the Victorian Age. In language, he is often compared with William Shakespeare for his adeptness with the vernacular and large vocabulary. Charles Dickens achieved a recognizable place among English writers through the use of the stylistic features in his fictional language. Oliver Twist is the best representative of Charles Dickens’style, which makes it the most appropriate choice for the present stylistic study on Charles Dickens. No one who has ever read the dehumanizing workhouse scenes of Oliver Twist and the dark, criminal underworld life can forget them. This thesis attempts to investigate Oliver Twist through the approach of modern stylistics, particularly the theory of linguistic devia-tion. This thesis consists of an introduction, the main body and a conclusion. The introduction offers a brief summary of the com-ments on Charles Dickens and Chapter X of Oliver Twist, introduces the newly rising linguistic deviation theories, and brings about the theories on which this thesis settles. The main body explores the deviation effects produced from four aspects: lexical deviation, grammatical deviation, graphological deviation, and semantic deviation. It endeavors to show Dickens ’manipulating language and the effects achieved through this manipulation. The conclusion mainly sums up the previous analysis, and reveals the theme of the novel, positive effect of linguistic deviation and significance of deviation application.

  3. Design of MPPT Controller Monitoring Software Based on QT Framework

    Science.gov (United States)

    Meng, X. Z.; Lu, P. G.

    2017-10-01

    The MPPT controller was a hardware device for tracking the maximum power point of solar photovoltaic array. Multiple controllers could be working as networking mode by specific communicating protocol. In this article, based on C++ GUI programming with Qt frame, we designed one sort of desktop application for monitoring and analyzing operational parameter of MPPT controller. The type of communicating protocol for building network was Modbus protocol which using Remote Terminal Unit mode and The desktop application of host computer was connected with all the controllers in the network through RS485 communication or ZigBee wireless communication. Using this application, user could monitor the parameter of controller wherever they were by internet.

  4. Protocol Adherence in Prehospital Medical Care Provided for Patients with Chest Pain and Loss of Consciousness; a Brief Report

    Directory of Open Access Journals (Sweden)

    Mostafa Mehrara

    2017-01-01

    Full Text Available Introduction: Although many protocols are available in the field of the prehospital medical care (PMC, there is still a notable gap between protocol based directions and applied clinical practice. This study measures the rate of protocol adherence in PMC provided for patients with chest pain and loss of consciousness (LOC.Method: In this cross-sectional study, 10 educated research assistants audited the situation of provided PMC for non-traumatic chest pain and LOC patients, presenting to the emergency department of a tertiary level teaching hospital, compare to national recommendations in these regards.Results: 101 cases with the mean age of 56.7 ± 12.3 years (30-78 were audited (55.4% male. 61 (60.3% patients had chest pain and 40 (39.7% cases had LOC. Protocol adherence rates for cardiac monitoring (62.3%, O2 therapy (32.8%, nitroglycerin administration (60.7%, and aspirin administration (52.5% in prehospital care of patients with chest pain were fair to poor. Protocol adherence rates for correct patient positioning (25%, O2 therapy (75%, cardiac monitoring (25%, pupils examination (25%, bedside glucometery (50%, and assessing for naloxone administration (55% in prehospital care of patients with LOC were fair to poor.Conclusion: There were more than 20% protocol violation regarding prehospital care of chest pain patients regarding cardiac monitoring, O2 therapy, and nitroglycerin and aspirin administration. There were same situation regarding O2 therapy, positioning, cardiac monitoring, pupils examination, bedside glucometery, and assessing for naloxone administration of LOC patients in prehospital setting.

  5. Decreasing the amplitude deviation of Guassian filter in surface roughness measurements

    Science.gov (United States)

    Liu, Bo; Wang, Yu

    2008-12-01

    A new approach for decreasing the amplitude characteristic deviation of Guassian filter in surface roughness measurements is presented in this paper. According to Central Limit Theorem, many different Guassian approximation filters could be constructed. By using first-order Butterworth filter and moving average filter to approximate Guassian filter, their directions of amplitude deviation are opposite, and their locations of extreme value are close. So the linear combination of them could reduce the amplitude deviation greatly. The maximum amplitude deviation is only about 0.11% through paralleling them. The algorithm of this new method is simple and its efficiency is high.

  6. Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia

    International Nuclear Information System (INIS)

    Moorin, Rachael E; Forsyth, Rene; Gibson, David J; Fox, Richard

    2013-01-01

    Technical data on local CT practice in Western Australia were collected for five major CT providers using a self-completed questionnaire. The CTDIvol DLP and effective dose for each protocol were obtained and providers were ranked according to radiation burden for each clinical scenario. The mean, median, 75th percentile and standard deviation were calculated for both effective dose and DLP for each scenario and these values were compared with published data. CT utilisation data were used to estimate the attributable radiation dose to the WA population and the potential change in population annual effective dose according to the protocol used was estimated. We found that wide variations in technique and radiation dose exist across providers for similar examinations, producing a higher radiation burden than reported internationally. As expected, the CT protocol used dramatically affects the radiation dose received, and this has a significant effect on annual population dose. This study highlights the need for recognition and understanding of both the degree of variation in radiation dose across providers and the relatively high radiation burden afforded by protocols in use in Western Australia so that necessary dialogue can be launched for practitioner consensus on appropriate diagnostic reference levels in CT scanning. (paper)

  7. Crucial Component Damage Detection, Monitoring and Mitigation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR project delivers an on-board structural health-monitoring (SHM) system with embedded sensors that sense mechanical impedance deviations to flag incipient...

  8. A deviation based assessment methodology for multiple machine health patterns classification and fault detection

    Science.gov (United States)

    Jia, Xiaodong; Jin, Chao; Buzza, Matt; Di, Yuan; Siegel, David; Lee, Jay

    2018-01-01

    Successful applications of Diffusion Map (DM) in machine failure detection and diagnosis have been reported in several recent studies. DM provides an efficient way to visualize the high-dimensional, complex and nonlinear machine data, and thus suggests more knowledge about the machine under monitoring. In this paper, a DM based methodology named as DM-EVD is proposed for machine degradation assessment, abnormality detection and diagnosis in an online fashion. Several limitations and challenges of using DM for machine health monitoring have been analyzed and addressed. Based on the proposed DM-EVD, a deviation based methodology is then proposed to include more dimension reduction methods. In this work, the incorporation of Laplacian Eigen-map and Principal Component Analysis (PCA) are explored, and the latter algorithm is named as PCA-Dev and is validated in the case study. To show the successful application of the proposed methodology, case studies from diverse fields are presented and investigated in this work. Improved results are reported by benchmarking with other machine learning algorithms.

  9. Enhanced safeguards via solution monitoring

    International Nuclear Information System (INIS)

    Burr, T.; Wangen, L.

    1996-09-01

    Solution monitoring is defined as the essentially continuous monitoring of solution level, density, and temperature in all tanks in the process that contain, or could contain, safeguards-significant quantities of nuclear material. This report describes some of the enhancements that solution monitoring could make to international safeguards. The focus is on the quantifiable benefits of solution monitoring, but qualitatively, solution monitoring can be viewed as a form of surveillance. Quantitatively, solution monitoring can in some cases improve diversion detection probability. For example, the authors show that under certain assumptions, solution monitoring can be used to reduce the standard deviation of the annual material balance, σ MB , from approximately 17 kg to approximately 4 kg. Such reduction in σ MB will not always be possible, as they discuss. However, in all cases, solution monitoring would provide assurance that the measurement error models are adequate so that one has confidence in his estimate of σ MB . Some of the results in this report were generated using data that were simulated with prototype solution monitoring software that they are developing. An accompanying document describes that software

  10. Minimizing Hexapod Robot Foot Deviations Using Multilayer Perceptron

    Directory of Open Access Journals (Sweden)

    Vytautas Valaitis

    2015-12-01

    Full Text Available Rough-terrain traversability is one of the most valuable characteristics of walking robots. Even despite their slower speeds and more complex control algorithms, walking robots have far wider usability than wheeled or tracked robots. However, efficient movement over irregular surfaces can only be achieved by eliminating all possible difficulties, which in many cases are caused by a high number of degrees of freedom, feet slippage, frictions and inertias between different robot parts or even badly developed inverse kinematics (IK. In this paper we address the hexapod robot-foot deviation problem. We compare the foot-positioning accuracy of unconfigured inverse kinematics and Multilayer Perceptron-based (MLP methods via theory, computer modelling and experiments on a physical robot. Using MLP-based methods, we were able to significantly decrease deviations while reaching desired positions with the hexapod's foot. Furthermore, this method is able to compensate for deviations of the robot arising from any possible reason.

  11. Importance of Standardized DXA Protocol for Assessing Physique Changes in Athletes.

    Science.gov (United States)

    Nana, Alisa; Slater, Gary J; Hopkins, Will G; Halson, Shona L; Martin, David T; West, Nicholas P; Burke, Louise M

    2016-06-01

    The implications of undertaking DXA scans using best practice protocols (subjects fasted and rested) or a less precise but more practical protocol in assessing chronic changes in body composition following training and a specialized recovery technique were investigated. Twenty-one male cyclists completed an overload training program, in which they were randomized to four sessions per week of either cold water immersion therapy or control groups. Whole-body DXA scans were undertaken with best practice protocol (Best) or random activity protocol (Random) at baseline, after 3 weeks of overload training, and after a 2-week taper. Magnitudes of changes in total, lean and fat mass from baseline-overload, overload-taper and baseline-taper were assessed by standardization (Δmean/SD). The standard deviations of change scores for total and fat-free soft tissue mass (FFST) from Random scans (2-3%) were approximately double those observed in the Best (1-2%), owing to extra random errors associated with Random scans at baseline. There was little difference in change scores for fat mass. The effect of cold water immersion therapy on baseline-taper changes in FFST was possibly harmful (-0.7%; 90% confidence limits ±1.2%) with Best scans but unclear with Random scans (0.9%; ±2.0%). Both protocols gave similar possibly harmful effects of cold water immersion therapy on changes in fat mass (6.9%; ±13.5% and 5.5%; ±14.3%, respectively). An interesting effect of cold water immersion therapy on training-induced changes in body composition might have been missed with a less precise scanning protocol. DXA scans should be undertaken with Best.

  12. Analyzing Vegetation Change in an Elephant-Impacted Landscape Using the Moving Standard Deviation Index

    Directory of Open Access Journals (Sweden)

    Timothy J. Fullman

    2014-01-01

    Full Text Available Northern Botswana is influenced by various socio-ecological drivers of landscape change. The African elephant (Loxodonta africana is one of the leading sources of landscape shifts in this region. Developing the ability to assess elephant impacts on savanna vegetation is important to promote effective management strategies. The Moving Standard Deviation Index (MSDI applies a standard deviation calculation to remote sensing imagery to assess degradation of vegetation. Used previously for assessing impacts of livestock on rangelands, we evaluate the ability of the MSDI to detect elephant-modified vegetation along the Chobe riverfront in Botswana, a heavily elephant-impacted landscape. At broad scales, MSDI values are positively related to elephant utilization. At finer scales, using data from 257 sites along the riverfront, MSDI values show a consistent negative relationship with intensity of elephant utilization. We suggest that these differences are due to varying effects of elephants across scales. Elephant utilization of vegetation may increase heterogeneity across the landscape, but decrease it within heavily used patches, resulting in the observed MSDI pattern of divergent trends at different scales. While significant, the low explanatory power of the relationship between the MSDI and elephant utilization suggests the MSDI may have limited use for regional monitoring of elephant impacts.

  13. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-10-01

    Full Text Available This study presents the use of a multi-channel opto-electronic sensor (OEPS to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA, and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05; a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001; the bias of BAA 0.85 bpm, the standard deviation (SD 9.20 bpm, and the limits of agreement (LOA from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001; the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  14. Large-Deviation Results for Discriminant Statistics of Gaussian Locally Stationary Processes

    Directory of Open Access Journals (Sweden)

    Junichi Hirukawa

    2012-01-01

    Full Text Available This paper discusses the large-deviation principle of discriminant statistics for Gaussian locally stationary processes. First, large-deviation theorems for quadratic forms and the log-likelihood ratio for a Gaussian locally stationary process with a mean function are proved. Their asymptotics are described by the large deviation rate functions. Second, we consider the situations where processes are misspecified to be stationary. In these misspecified cases, we formally make the log-likelihood ratio discriminant statistics and derive the large deviation theorems of them. Since they are complicated, they are evaluated and illustrated by numerical examples. We realize the misspecification of the process to be stationary seriously affecting our discrimination.

  15. A Novel and Validated Protocol for Performing MIC Tests to Determine the Susceptibility of Piscirickettsia salmonis Isolates to Florfenicol and Oxytetracycline

    Directory of Open Access Journals (Sweden)

    Sergio Contreras-Lynch

    2017-07-01

    Full Text Available This paper presents a validated protocol, using a novel, specifically formulated medium, to perform broth microdilution antimicrobial susceptibility assays of the salmonid bacterial pathogen Piscirickettsia salmonis. The minimum inhibitory concentrations (MIC for florfenicol and oxytetracycline against 58 P. salmonis isolates recovered from various outbreaks occurred in Chilean salmonid farms were determined using this protocol. Normalized resistance interpretation (NRI analysis was applied to these data to calculate appropriate protocol-specific epidemiological cut-off values. These cut-off values allow the isolates to be categorized as either fully susceptible wild type (WT members of this species, or as manifesting reduced susceptibility non-wild type (NWT. The distribution of MIC values of florfenicol was bimodal and the distribution of the normalized values for the putative WT observation had a standard deviation of 0.896 log2 μg mL-1. This analysis calculated a cut-off value of ≤0.25 μg mL-1 and categorized 33 (56% of the isolates as manifesting reduced susceptibility to florfenicol. For the oxytetracycline MIC data the NRI analysis also treated the distribution as bimodal. The distribution of the normalized values for the putative WT observation had a standard deviation of 0.951 log2 μg mL-1. This analysis gave a cut-off value of ≤0.5 μg mL-1 and categorized five isolates (9% as manifesting reduced susceptibility to oxytetracycline. The susceptibility testing protocol developed in this study was capable of generating MIC data from all the isolates tested. On the basis of the precision of the data it generated, and the degree of separation of values for WT and NWT it achieved, it is argued that this protocol has the performance characteristics necessary for it to be considered as a standard protocol.

  16. A robust standard deviation control chart

    NARCIS (Netherlands)

    Schoonhoven, M.; Does, R.J.M.M.

    2012-01-01

    This article studies the robustness of Phase I estimators for the standard deviation control chart. A Phase I estimator should be efficient in the absence of contaminations and resistant to disturbances. Most of the robust estimators proposed in the literature are robust against either diffuse

  17. Using generalizability theory to develop clinical assessment protocols.

    Science.gov (United States)

    Preuss, Richard A

    2013-04-01

    Clinical assessment protocols must produce data that are reliable, with a clinically attainable minimal detectable change (MDC). In a reliability study, generalizability theory has 2 advantages over classical test theory. These advantages provide information that allows assessment protocols to be adjusted to match individual patient profiles. First, generalizability theory allows the user to simultaneously consider multiple sources of measurement error variance (facets). Second, it allows the user to generalize the findings of the main study across the different study facets and to recalculate the reliability and MDC based on different combinations of facet conditions. In doing so, clinical assessment protocols can be chosen based on minimizing the number of measures that must be taken to achieve a realistic MDC, using repeated measures to minimize the MDC, or simply based on the combination that best allows the clinician to monitor an individual patient's progress over a specified period of time.

  18. Implementing the Kyoto protocol in Europe: Interactions between international and Community controls

    International Nuclear Information System (INIS)

    Tabau, Anne-Sophie

    2011-07-01

    This bibliographical note presents a book which discusses the coexistence of the Kyoto protocol and of a regional regime within the European Union for the actual application of rules requiring mechanisms of control. The international regime implements a continuous monitoring which combines conventional techniques and more intrusive procedures. The European Community introduced a non-contentious mechanism with a large and strong law basis and sanction ability. The author assesses the ability of the monitoring system as a whole to ensure the very credibility of the Protocol. She also assesses the reliability of international and community economic tools which aim at reducing greenhouse gas emissions at a minimum cost. She also discusses the desirable evolutions of the regime of struggle against climate changes

  19. Deviation from Covered Interest Rate Parity in Korea

    Directory of Open Access Journals (Sweden)

    Seungho Lee

    2003-06-01

    Full Text Available This paper tested the factors which cause deviation from covered interest rate parity (CIRP in Korea, using regression and VAR models. The empirical evidence indicates that the difference between the swap rate and interest rate differential exists and is greatly affected by variables which represent the currency liquidity situation of foreign exchange banks. In other words, the deviation from CIRP can easily occur due to the lack of foreign exchange liquidity of banks in a thin market, despite few capital constraints, small transaction costs, and trivial default risk in Korea.

  20. Clinical and biochemical monitoring of patients with fatty acid oxidation disorders

    DEFF Research Database (Denmark)

    Lund, Allan Meldgaard; Skovby, Flemming; Vestergaard, Helle

    2010-01-01

    complicated assessments by a neuropsychologist, speech therapist, or physical and occupational therapists. Paraclinical measurements are not used for short-chain and medium-chain disorders; electrocardiography (including 24 h monitoring) and echocardiography are done for most patients with long......Evidence-based guidelines for monitoring patients with disorders in fatty acid oxidation (FAO) are lacking, and most protocols are based on expert statements. Here, we describe our protocol for Danish patients. Clinical monitoring is the most important measure and has the main aims of checking...... carnitine is measured to monitor carnitine supplementation in patients with multiple acyl-coenzyme A dehydrogenase deficiency (MADD) and carnitine transporter deficiency (CTD) and to follow metabolic control and disclose deficiency states in other FAO disorders. We are evaluating long-chain acylcarnitines...

  1. Safety of protocol violations in acute stroke tPA administration.

    Science.gov (United States)

    Lyerly, Michael J; Albright, Karen C; Boehme, Amelia K; Bavarsad Shahripour, Reza; Houston, James T; Rawal, Pawan V; Kapoor, Niren; Alvi, Muhammad; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2014-01-01

    Intravenous (IV) tissue plasminogen activator remains the only approved therapy for acute ischemic stroke (AIS) in the United States; however, less than 10% of patients receive treatment. This is partially because of the large number of contraindications, narrow treatment window, and physician reluctance to deviate from these criteria. We retrospectively analyzed consecutive patients who received IV thrombolysis at our stroke center for National Institute of Neurological Disorders and Stroke (NINDS) protocol violations and rates of symptomatic intracerebral hemorrhage (sICH). Other outcome variables included systemic hemorrhage, modified Rankin Scale at discharge, and discharge disposition. A total of 212 patients were identified in our stroke registry between 2009 and 2011 and included in the analysis. Protocol violations occurred in 76 patients (36%). The most common violations were thrombolysis beyond 3 hours (26%), aggressive blood pressure management (15%), elevated prothrombin time (PT) or partial thromboplastin time (PTT) (6.6%), minor or resolving deficits (4.2%), unclear time of onset (3.9%), and stroke within 3 months (3%). There were no significant differences in any of the safety outcomes or discharge disposition between patients with or without protocol violations. Controlling for age, National Institutes of Health Stroke Scale on admission, and glucose on admission, there was no significant increase in sICH (odds ratio: 3.8; 95% confidence interval: .37-38.72) in the patients who had protocol violations. Despite more than one third of patients receiving thrombolysis with protocol violations, overall rates of hemorrhage remained low and did not differ from those who did not have violations. Our data support the need to expand access to thrombolysis in AIS patients. Published by Elsevier Inc.

  2. A guide to processing bat acoustic data for the North American Bat Monitoring Program (NABat)

    Science.gov (United States)

    Reichert, Brian; Lausen, Cori; Loeb, Susan; Weller, Ted; Allen, Ryan; Britzke, Eric; Hohoff, Tara; Siemers, Jeremy; Burkholder, Braden; Herzog, Carl; Verant, Michelle

    2018-06-14

    The North American Bat Monitoring Program (NABat) aims to improve the state of conservation science for all species of bats shared by the United States, Canada, and Mexico. To accomplish this goal, NABat offers guidance and standardized protocols for acoustic monitoring of bats. In this document, “A Guide to Processing Bat Acoustic Data for the North American Bat Monitoring Program (NABat),” we provide general recommendations and specific workflows for the process of identifying bat species from acoustic files recorded using the NABat stationary point and mobile transect acoustic monitoring protocols.

  3. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols

    Directory of Open Access Journals (Sweden)

    Aamir Shahzad

    2016-06-01

    Full Text Available Substantial changes have occurred in the Information Technology (IT sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.

  4. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols.

    Science.gov (United States)

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-06-14

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.

  5. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols

    Science.gov (United States)

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-01-01

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network. PMID:27314351

  6. [A security protocol for the exchange of personal medical data via Internet: monitoring treatment and drug effects].

    Science.gov (United States)

    Viviani, R; Fischer, J; Spitzer, M; Freudenmann, R W

    2004-04-01

    We present a security protocol for the exchange of medical data via the Internet, based on the type/domain model. We discuss two applications of the protocol: in a system for the exchange of data for quality assurance, and in an on-line database of adverse reactions to drug use. We state that a type/domain security protocol can successfully comply with the complex requirements for data privacy and accessibility typical of such applications.

  7. Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation

    Science.gov (United States)

    Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann

    2017-01-01

    This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…

  8. Studying protocol-based pain management in the emergency department

    Directory of Open Access Journals (Sweden)

    Akkamahadevi Patil

    2017-01-01

    Full Text Available Background: Majority of the patients presenting to emergency department (ED have pain. ED oligoanalgesia remains a challenge. Aims: This study aims to study the effect of implementing a protocol-based pain management in the ED on (1 time to analgesia and (2 adequacy of analgesia obtained. Settings and Design: Cross-sectional study in the ED. Methods: Patients aged 18–65 years of age with pain of numeric rating scale (NRS ≥4 were included. A series of 100 patients presenting before introduction of the protocol-based pain management were grouped “pre-protocol,” and managed as per existing practice. Following this, a protocol for management of all patients presenting to ED with pain was implemented. Another series of 100 were grouped as “post-protocol” and managed as per the new pain management protocol. The data of patients from both the groups were collected and analyzed. Statistical Analysis Used: Descriptive statistical tests such as percentage, mean and standard deviation and inferential statistical tests such as Pearson coefficient, Student's t-test were applied. Differences were interpreted as significant when P < 0.05. Results: Mean time to administer analgesic was significantly lesser in the postprotocol group (preprotocol 20.30 min vs. postprotocol 13.05 min; P < 0.001. There was significant difference in the pain relief achieved (change in NRS between the two groups, with greater pain relief achieved in the postprotocol group (preprotocol group 4.6800 vs. postprotocol group 5.3600; P < 0.001. Patients' rating of pain relief (assessed on E5 scale was significantly higher in the postprotocol group (preprotocol 3.91 vs. postprotocol 4.27; P = 0.001. Patients' satisfaction (North American Spine Society scale with the overall treatment was also compared and found to be significantly higher in postprotocol group (mean: preprotocol 1.59 vs. postprotocol 1.39; P = 0.008. Conclusion: Protocol-based pain management provided timely and

  9. A better norm-referenced grading using the standard deviation criterion.

    Science.gov (United States)

    Chan, Wing-shing

    2014-01-01

    The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.

  10. Design and implementation on wireless transmission platform of area radiation monitoring data

    International Nuclear Information System (INIS)

    Li Dan; Ge Liangquan; Lai Wanchang; Ren Yong; Liu Huijun; Wang Guangxi

    2011-01-01

    To solve data transmission problems of radiation area monitoring system, Wireless transmission platform is built based on ZigBee module, thus wireless transmission between the radiation area central node and the monitoring points is achieved. It introduces the framework of ZigBee protocol, APL applications between FFD and RFD module, FFD, module and central node host, and RFD module and monitoring equipment, are developed using simplified protocol stack. Wireless network is set up using a FFD module and two RFD modules, the results show that RSSI are above 50, and the data communication is normal for the transmission distance of 60 m. (authors)

  11. An "Off-the-Shelf" System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy.

    Science.gov (United States)

    Neal, Robert E; Kavnoudias, Helen; Thomson, Kenneth R

    2015-06-01

    Irreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators. We describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator. Accuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues. This system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents-sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

  12. Development of high-reliable real-time communication network protocol for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Sang; Kim, Young Sik [Korea National University of Education, Chongwon (Korea); No, Hee Chon [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-04-01

    In this research, we first define protocol subsets for SMART(System-integrated Modular Advanced Reactor) communication network based on the requirement of SMART MMIS transmission delay and traffic requirements and OSI(Open System Interconnection) 7 layers' network protocol functions. Also, current industrial purpose LAN protocols are analyzed and the applicability of commercialized protocols are checked. For the suitability test, we have applied approximated SMART data traffic and maximum allowable transmission delay requirement. With the simulation results, we conclude that IEEE 802.5 and FDDI which is an ANSI standard, is the most suitable for SMART. We further analyzed the FDDI and token ring protocols for SMART and nuclear plant network environment including IEEE 802.4, IEEE 802.5, and ARCnet. The most suitable protocol for SMART is FDDI and FDDI MAC and RMT protocol specifications have been verified with LOTOS and the verification results show that FDDI MAC and RMT satisfy the reachability and liveness, but does not show deadlock and livelock. Therefore, we conclude that FDDI MAC and RMT is highly reliable protocol for SMART MMIS network. After that, we consider the stacking fault of IEEE 802.5 token ring protocol and propose a fault tolerant MAM(Modified Active Monitor) protocol. The simulation results show that the MAM protocol improves lower priority traffic service rate when stacking fault occurs. Therefore, proposed MAM protocol can be applied to SMART communication network for high reliability and hard real-time communication purpose in data acquisition and inter channel network. (author). 37 refs., 79 figs., 39 tabs.

  13. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    Science.gov (United States)

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  14. Statistical analysis of dragline monitoring data

    Energy Technology Data Exchange (ETDEWEB)

    Mirabediny, H.; Baafi, E.Y. [University of Tehran, Tehran (Iran)

    1998-07-01

    Dragline monitoring systems are normally the best tool used to collect data on the machine performance and operational parameters of a dragline operation. This paper discusses results of a time study using data from a dragline monitoring system captured over a four month period. Statistical summaries of the time study in terms of average values, standard deviation and frequency distributions showed that the mode of operation and the geological conditions have a significant influence on the dragline performance parameters. 6 refs., 14 figs., 3 tabs.

  15. Protocol adherence and the ability to achieve target haemoglobin levels in haemodialysis patients.

    Science.gov (United States)

    Chan, Kevin; Moran, John; Hlatky, Mark; Lafayette, Richard

    2009-06-01

    Anemia management remains complicated in patients with endstage renal disease on hemodialysis. We wished to evaluate the effect of protocol adherence to EPO and intravenous iron dosing on achieving the desired range of hemoglobin levels. A cohort of hemodialysis patients was studied to evaluate the rate of adherence to EPO and iron dosing protocols over a 5 month period. A database was completed to evaluate all known comorbidities, demographic factors, and facility issues that might affect hemoglobin levels. A logistic regression model was employed to evaluate the effect of adherence to the anemia protocols on the probability of achieving a hemoglobin level below, within or above the targeted range of 11-12.5 g/dl. Among 2114 patients, we found that adherence to both the EPO and iron dosing protocol resulted in the greatest probability of achieving the target hemoglobin range (56 +/- 5% in anemia protocol adherent patients versus 42 +/- 7% in non adherent patients). This was predominantly due to a lowered risk of having above target hemoglobin levels rather than below. The use of the anemia protocols was associated with lower rates of hospitalization (9 +/- 0.7 visits/100 months in adherent group vs 15 +/- 2 in non adherent group) and lower utilization of both EPO and intravenous iron. Furthermore, patients in the adherent groups had less variability of their hemoglobin levels month by month, at least as judged by standard deviation. Adherence to anemia protocols, as practiced in the dialysis units included in this cohort, may improve hemodialysis patients' ability to achieve target hemoglobin levels, and by avoiding above target hemoglobin values, lower drug utilization and reduce variability of hemoglobin levels.

  16. Research on Multioperator silk screen printer Based on Communication Protocol Macro

    Directory of Open Access Journals (Sweden)

    Zhiming Zhang

    2018-01-01

    Full Text Available Multioperator silk screen printer is automatic silk screen printing equipment. There are many advantages, such as energy saving, reduce the labor intensity and so on. The control system consists of an intermittent movement main motor and eight color working station printing cycle motion motors. The system controls nine frequency converters through protocol macro communication by using PLC. This paper studies the principle and process characteristics of multioperator silk screen printer. Besides, this paper adopts protocol macro sequence generation method for communication between PLC and frequency converter. This method can control the programming of parameters, such as frequency, operation and monitoring. It also can realize the printing of eight color working stations and monitor the printing status in real time. The practical application proves that the method meets the technical requirements and the reliability is good.

  17. Measurement and analysis of the thoracic patient setup deviations in routine radiotherapy

    International Nuclear Information System (INIS)

    Jia Mingxuan; Zou Huawei; Wu Rong; Sun Jian; Dong Xiaoqi

    2003-01-01

    Objective: To determine the magnitude of the setup deviations of the thoracic patients in routine radiotherapy. Methods: Altogether 408 films for 21 thoracic patients were recorded using the electronic portal imaging device (EPID), and comparison with reference CT simulator digitally-reconstructed radiograph (DRR) for anterior-posterior fields was performed. The deviation of setup for 21 patients in the left-right (RL), superior-inferior (SI) directions and rotation about the anterior-posterior (AP) axis were measured and analyzed. Results: Without immobilization device, the mean translational and rotational setup deviations were (0.7±3.1) mm and (1.5±4.1) mm in the RL and SI directions, respectively, and (0.3±2.4) degree about AP axis. With immobilization device, the mean translational and rotational setup deviations were (0.5±2.4) mm and (0.8±2.7) mm in the RL and SI directions respectively, and (0.2±1.6) degree about AP axis. Conclusion: The setup deviations in thoracic patients irradiation may be reduced with the use of the immobilization device. The setup deviation in the SI direction is greater than that in the RL direction. The setup deviations are mainly random errors

  18. Sea Surface Height Deviation, Aviso, 0.25 degrees, Global, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aviso Sea Surface Height Deviation is the deviation from the mean geoid as measured from 1993 - 1995. This is Science Quality data.

  19. 48 CFR 201.404 - Class deviations.

    Science.gov (United States)

    2010-10-01

    ..., and the Defense Logistics Agency, may approve any class deviation, other than those described in 201...) Diminish any preference given small business concerns by the FAR or DFARS; or (D) Extend to requirements imposed by statute or by regulations of other agencies such as the Small Business Administration and the...

  20. Preliminary results of the Gas Electron Multiplier (GEM) as real-time beam monitor in hadron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Aza, E., E-mail: eleni.aza@cern.ch [CERN, Geneva 23, 1211 Geneva (Switzerland); AUTH, Department of Physics, 54124 Thessaloniki (Greece); Ciocca, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Murtas, F. [CERN, Geneva 23, 1211 Geneva (Switzerland); LNF-INFN, Via Fermi 40, 00044 Frascati (Italy); Puddu, S. [CERN, Geneva 23, 1211 Geneva (Switzerland); AEC-LHEP, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Pullia, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Silari, M. [CERN, Geneva 23, 1211 Geneva (Switzerland)

    2017-01-01

    The use of proton and carbon ion beams in cancer therapy (also known as hadron therapy) is progressively growing worldwide due to their improved dose distributions, sparing of healthy tissues and (for carbon ions) increased radiobiological effectiveness especially for radio-resistant tumours. Strict Quality Assurance (QA) protocols need to be followed for guaranteeing the clinical beam specifications. The aim of this study was to assess the performance of a gaseous detector based on the Gas Electron Multiplier (GEM) technology for measuring the beam spot dimensions and the homogeneity of the scanned irradiation field, which are daily QA tasks commonly performed using radiochromic films. Measurements performed at the National Centre for Oncological Hadron Therapy (CNAO) in Pavia (Italy) showed that the detector is able to monitor the 2D beam image on-line with a pad granularity of 2 mm and a response proportional to the number of delivered particles. The dose homogeneity was measured with low deviation from the results obtained with radiochromic films.

  1. Large deviations in the presence of cooperativity and slow dynamics

    Science.gov (United States)

    Whitelam, Stephen

    2018-06-01

    We study simple models of intermittency, involving switching between two states, within the dynamical large-deviation formalism. Singularities appear in the formalism when switching is cooperative or when its basic time scale diverges. In the first case the unbiased trajectory distribution undergoes a symmetry breaking, leading to a change in shape of the large-deviation rate function for a particular dynamical observable. In the second case the symmetry of the unbiased trajectory distribution remains unbroken. Comparison of these models suggests that singularities of the dynamical large-deviation formalism can signal the dynamical equivalent of an equilibrium phase transition but do not necessarily do so.

  2. Improving Neuromuscular Monitoring and Reducing Residual Neuromuscular Blockade With E-Learning: Protocol for the Multicenter Interrupted Time Series INVERT Study.

    Science.gov (United States)

    Thomsen, Jakob Louis Demant; Mathiesen, Ole; Hägi-Pedersen, Daniel; Skovgaard, Lene Theil; Østergaard, Doris; Engbaek, Jens; Gätke, Mona Ring

    2017-10-06

    -learning module was implemented in 6 anesthesia departments on 21 November 2016. Currently, we are collecting postintervention data. The final dataset will include data from more than 10,000 anesthesia procedures. We expect to publish the results in late 2017 or early 2018. With a dataset consisting of thousands of general anesthesia procedures, the INVERT study will assess whether an e-learning module can increase anesthetists' use of neuromuscular monitoring. Clinicaltrials.gov NCT02925143; https://clinicaltrials.gov/ct2/show/NCT02925143 (Archived by WebCite® at http://www.webcitation.org/6s50iTV2x). ©Jakob Louis Demant Thomsen, Ole Mathiesen, Daniel Hägi-Pedersen, Lene Theil Skovgaard, Doris Østergaard, Jens Engbaek, Mona Ring Gätke. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 06.10.2017.

  3. A hash based mutual RFID tag authentication protocol in telecare medicine information system.

    Science.gov (United States)

    Srivastava, Keerti; Awasthi, Amit K; Kaul, Sonam D; Mittal, R C

    2015-01-01

    Radio Frequency Identification (RFID) is a technology which has multidimensional applications to reduce the complexity of today life. Everywhere, like access control, transportation, real-time inventory, asset management and automated payment systems etc., RFID has its enormous use. Recently, this technology is opening its wings in healthcare environments, where potential applications include patient monitoring, object traceability and drug administration systems etc. In this paper, we propose a secure RFID-based protocol for the medical sector. This protocol is based on hash operation with synchronized secret. The protocol is safe against active and passive attacks such as forgery, traceability, replay and de-synchronization attack.

  4. Traffic Adaptive MAC Protocols in Wireless Body Area Networks

    Directory of Open Access Journals (Sweden)

    Farhan Masud

    2017-01-01

    Full Text Available In Wireless Body Area Networks (WBANs, every healthcare application that is based on physical sensors is responsible for monitoring the vital signs data of patient. WBANs applications consist of heterogeneous and dynamic traffic loads. Routine patient’s observation is described as low-load traffic while an alarming situation that is unpredictable by nature is referred to as high-load traffic. This paper offers a thematic review of traffic adaptive Medium Access Control (MAC protocols in WBANs. First, we have categorized them based on their goals, methods, and metrics of evaluation. The Zigbee standard IEEE 802.15.4 and the baseline MAC IEEE 802.15.6 are also reviewed in terms of traffic adaptive approaches. Furthermore, a comparative analysis of the protocols is made and their performances are analyzed in terms of delay, packet delivery ratio (PDR, and energy consumption. The literature shows that no review work has been done on traffic adaptive MAC protocols in WBANs. This review work, therefore, could add enhancement to traffic adaptive MAC protocols and will stimulate a better way of solving the traffic adaptivity problem.

  5. Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, B. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Keller, H. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, 150 College Street, Toronto, Ontario M5S 3E2 (Canada); Jaffray, D.; Coolens, C. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, University of Toronto, 150 College Street, Toronto, Ontario M5S 3E2 (Canada); Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1L5 (Canada)

    2013-08-15

    Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from

  6. Microplastics in seafood: Benchmark protocol for their extraction and characterization.

    Science.gov (United States)

    Dehaut, Alexandre; Cassone, Anne-Laure; Frère, Laura; Hermabessiere, Ludovic; Himber, Charlotte; Rinnert, Emmanuel; Rivière, Gilles; Lambert, Christophe; Soudant, Philippe; Huvet, Arnaud; Duflos, Guillaume; Paul-Pont, Ika

    2016-08-01

    Pollution of the oceans by microplastics (studies have investigated the level of contamination of marine organisms collected in situ. For extraction and characterization of microplastics in biological samples, the crucial step is the identification of solvent(s) or chemical(s) that efficiently dissolve organic matter without degrading plastic polymers for their identification in a time and cost effective way. Most published papers, as well as OSPAR recommendations for the development of a common monitoring protocol for plastic particles in fish and shellfish at the European level, use protocols containing nitric acid to digest the biological tissues, despite reports of polyamide degradation with this chemical. In the present study, six existing approaches were tested and their effects were compared on up to 15 different plastic polymers, as well as their efficiency in digesting biological matrices. Plastic integrity was evaluated through microscopic inspection, weighing, pyrolysis coupled with gas chromatography and mass spectrometry, and Raman spectrometry before and after digestion. Tissues from mussels, crabs and fish were digested before being filtered on glass fibre filters. Digestion efficiency was evaluated through microscopical inspection of the filters and determination of the relative removal of organic matter content after digestion. Five out of the six tested protocols led to significant degradation of plastic particles and/or insufficient tissue digestion. The protocol using a KOH 10% solution and incubation at 60 °C during a 24 h period led to an efficient digestion of biological tissues with no significant degradation on all tested polymers, except for cellulose acetate. This protocol appeared to be the best compromise for extraction and later identification of microplastics in biological samples and should be implemented in further monitoring studies to ensure relevance and comparison of environmental and seafood product quality studies

  7. The phonatory deviation diagram: a novel objective measurement of vocal function.

    Science.gov (United States)

    Madazio, Glaucya; Leão, Sylvia; Behlau, Mara

    2011-01-01

    To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.

  8. Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds.

    Science.gov (United States)

    Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto

    2015-02-01

    Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for

  9. Statistical properties of the deviations of f 0 F 2 from monthly medians

    Directory of Open Access Journals (Sweden)

    Y. Tulunay

    2002-06-01

    Full Text Available The deviations of hourly f 0 F 2 from monthly medians for 20 stations in Europe during the period 1958-1998 are studied. Spectral analysis is used to show that, both for original data (for each hour and for the deviations from monthly medians, the deterministic components are the harmonics of 11 years (solar cycle, 1 year and its harmonics, 27 days and 12 h 50.49 m (2nd harmonic of lunar rotation period L 2 periodicities. Using histograms for one year samples, it is shown that the deviations from monthly medians are nearly zero mean (mean < 0.5 and approximately Gaussian (relative difference range between %10 to %20 and their standard deviations are larger for daylight hours (in the range 5-7. It is shown that the amplitude distribution of the positive and negative deviations is nearly symmetrical at night hours, but asymmetrical for day hours. The positive and negative deviations are then studied separately and it is observed that the positive deviations are nearly independent of R12 except for high latitudes, but negative deviations are modulated by R12 . The 90% confidence interval for negative deviations for each station and each hour is computed as a linear model in terms of R12. After correction for local time, it is shown that for all hours the confidence intervals increase with latitude but decrease above 60N. Long-term trend analysis showed that there is an increase in the amplitude of positive deviations from monthly means irrespective of the solar conditions. Using spectral analysis it is also shown that the seasonal dependency of negative deviations is more accentuated than the seasonal dependency of positive deviations especially at low latitudes. In certain stations, it is also observed that the 4th harmonic of 1 year corresponding to a periodicity of 3 months, which is missing in f 0 F 2 data, appears in the spectra of negative variations.

  10. VAR Portfolio Optimal: Perbandingan Antara Metode Markowitz Dan Mean Absolute Deviation

    OpenAIRE

    Sartono, R. Agus; Setiawan, Arie Andika

    2006-01-01

    Portfolio selection method which have been introduced by Harry Markowitz (1952) used variance or deviation standard as a measure of risk. Kanno and Yamazaki (1991) introduced another method and used mean absolute deviation as a measure of risk instead of variance. The Value-at Risk (VaR) is a relatively new method to capitalized risk that been used by financial institutions. The aim of this research is compare between mean variance and mean absolute deviation of two portfolios. Next, we attem...

  11. Evaluation of Protocols for Measuring Leaf Photosynthetic Properties of Field-Grown Rice

    Directory of Open Access Journals (Sweden)

    Chang Tian-gen

    2017-01-01

    Full Text Available Largely due to the heterogeneity of environmental parameters and the logistical difficulty of moving photosynthetic equipment in the paddy fields, effective measurement of lowland rice photosynthesis is still a challenge. In this study, we showed that measuring detached rice leaves in the laboratory can not effectively represent the parameters measured in situ. We further described a new indoor facility, high-efficiency all-weather photosynthetic measurement system (HAPS, and the associated measurement protocol to enable whole-weather measurement of photosynthetic parameters of rice grown in the paddy fields. Using HAPS, we can conduct photosynthetic measurements with a time span much longer than that appropriate for the outdoor measurements. Comparative study shows that photosynthetic parameters obtained with the new protocol can effectively represent the parameters in the fields. There was much less standard deviation for measurements using HAPS compared to the outdoor measurements, no matter for technical replications of each recording or for biological replications of each leaf position. This new facility and protocol enables rice photosynthetic physiology studies to be less tough but more efficient, and provides a potential option for large scale studies of rice leaf photosynthesis.

  12. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Kayatürk, Nur; Altunkan, Erkan

    2007-08-01

    Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. One hundred and twenty-one patients, older than 30 years of age, were studied and classified on the basis of the range of the International Protocol. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. A total of 33 participants were selected for each validation study. During the validation study, 99 measurements were performed on 33 participants for comparison. The first phase was performed on 15 participants, and if the device passed this phase, 18 more participants were selected. Having a two-fold purpose, this study was conducted on both adult and obese adult patients. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.1+/-4.0 mmHg for systolic BP (SBP) and -0.5+/-3.5 mmHg for diastolic BP (DBP) in the adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 88, 96, and 97 for SBP, and 88, 98, and 99 for DBP were M6 automatic monitor, which measures BP at the upper arm, produced results in accordance with the criteria of phases 2.1 and 2.2 in both SBP and DBP, when applied to adults and to obese adults. It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.

  13. Large deviation function for a driven underdamped particle in a periodic potential

    Science.gov (United States)

    Fischer, Lukas P.; Pietzonka, Patrick; Seifert, Udo

    2018-02-01

    Employing large deviation theory, we explore current fluctuations of underdamped Brownian motion for the paradigmatic example of a single particle in a one-dimensional periodic potential. Two different approaches to the large deviation function of the particle current are presented. First, we derive an explicit expression for the large deviation functional of the empirical phase space density, which replaces the level 2.5 functional used for overdamped dynamics. Using this approach, we obtain several bounds on the large deviation function of the particle current. We compare these to bounds for overdamped dynamics that have recently been derived, motivated by the thermodynamic uncertainty relation. Second, we provide a method to calculate the large deviation function via the cumulant generating function. We use this method to assess the tightness of the bounds in a numerical case study for a cosine potential.

  14. Security Enhanced User Authentication Protocol for Wireless Sensor Networks Using Elliptic Curves Cryptography

    Directory of Open Access Journals (Sweden)

    Younsung Choi

    2014-06-01

    Full Text Available Wireless sensor networks (WSNs consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC for WSNs. However, it turned out that Yeh et al.’s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.’s protocol. However, Shi et al.’s improvement introduces other security weaknesses. In this paper, we show that Shi et al.’s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs.

  15. Security enhanced user authentication protocol for wireless sensor networks using elliptic curves cryptography.

    Science.gov (United States)

    Choi, Younsung; Lee, Donghoon; Kim, Jiye; Jung, Jaewook; Nam, Junghyun; Won, Dongho

    2014-06-10

    Wireless sensor networks (WSNs) consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC) for WSNs. However, it turned out that Yeh et al.'s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.'s protocol. However, Shi et al.'s improvement introduces other security weaknesses. In this paper, we show that Shi et al.'s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs.

  16. A Comparison of Routing Protocol for WSNs: Redundancy Based Approach A Comparison of Routing Protocol for WSNs: Redundancy Based Approach

    Directory of Open Access Journals (Sweden)

    Anand Prakash

    2014-03-01

    Full Text Available Wireless Sensor Networks (WSNs with their dynamic applications gained a tremendous attention of researchers. Constant monitoring of critical situations attracted researchers to utilize WSNs at vast platforms. The main focus in WSNs is to enhance network localization as much as one could, for efficient and optimal utilization of resources. Different approaches based upon redundancy are proposed for optimum functionality. Localization is always related with redundancy of sensor nodes deployed at remote areas for constant and fault tolerant monitoring. In this work, we propose a comparison of classic flooding and the gossip protocol for homogenous networks which enhances stability and throughput quiet significantly.  

  17. Evaluation of video transmission of MAC protocols in wireless sensor network

    Science.gov (United States)

    Maulidin, Mahmuddin, M.; Kamaruddin, L. M.; Elsaikh, Mohamed

    2016-08-01

    Wireless Sensor Network (WSN) is a wireless network which consists of sensor nodes scattered in a particular area which are used to monitor physical or environment condition. Each node in WSN is also scattered in sensor field, so an appropriate scheme of MAC protocol should have to develop communication link for data transferring. Video transmission is one of the important applications for the future that can be transmitted with low aspect in side of cost and also power consumption. In this paper, comparison of five different MAC WSN protocol for video transmission namely IEEE 802.11 standard, IEEE 802.15.4 standard, CSMA/CA, Berkeley-MAC, and Lightweight-MAC protocol are studied. Simulation experiment has been conducted in OMNeT++ with INET network simulator software to evaluate the performance. Obtained results indicate that IEEE 802.11 works better than other protocol in term of packet delivery, throughput, and latency.

  18. An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Neal, Robert E., E-mail: Robert.Neal@alfred.org.au; Kavnoudias, Helen; Thomson, Kenneth R. [The Alfred Hospital, Radiology Research Unit, Department of Radiology (Australia)

    2015-06-15

    IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

  19. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  20. Protocol-driven remote monitoring of cardiac resynchronization therapy as part of a heart failure disease management strategy.

    Science.gov (United States)

    Smeets, Christophe J P; Verbrugge, Frederik H; Vranken, Julie; Van der Auwera, Jo; Mullens, Wilfried; Dupont, Matthias; Grieten, Lars; De Cannière, Hélène; Lanssens, Dorien; Vandenberk, Thijs; Storms, Valerie; Thijs, Inge M; Vandervoort, Pieter

    2017-08-14

    Cardiac resynchronisation therapy (CRT) is an established treatment for heart failure (HF) with reduced ejection fraction. CRT devices are equipped with remote monitoring functions, which are pivotal in the detection of device problems, but may also facilitate disease management. The aim of this study was to provide a comprehensive overview of the clinical interventions taken based on remote monitoring. This is a single centre observational study of consecutive CRT patients (n = 192) participating in protocol-driven remote follow-up. Incoming technical- and disease-related alerts were analysed together with subsequently triggered interventions. During 34 ± 13 months of follow-up, 1372 alert-containing notifications were received (2.53 per patient-year of follow-up), comprising 1696 unique alerts (3.12 per patient-year of follow-up). In 60%, notifications resulted in a phone contact. Technical alerts constituted 8% of incoming alerts (0.23 per patient-year of follow-up). Rhythm (1.43 per patient-year of follow-up) and bioimpedance alerts (0.98 per patient-year of follow-up) were the most frequent disease-related alerts. Notifications included a rhythm alert in 39%, which triggered referral to the emergency room (4%), outpatient cardiology clinic (36%) or general practitioner (7%), or resulted in medication changes (13%). Sole bioimpedance notifications resulted in a telephone contact in 91%, which triggered outpatient evaluation in 8% versus medication changes in 10%. Clinical outcome was excellent with 97% 1-year survival. Remote CRT follow-up resulted in 0.23 technical- versus 2.64 disease-related alerts annually. Rhythm and bioimpedance notifications constituted the majority of incoming notifications which triggered an actual intervention in 22% and 15% of cases, respectively.

  1. Chilean Nutrition Management Protocol for Patients With Phenylketonuria

    Directory of Open Access Journals (Sweden)

    Gabriela Castro

    2017-02-01

    Full Text Available Since neonatal screening and early nutritional treatment began, it has been possible to reverse the neurological damage that phenylketonuria (PKU causes. Scientific evidence gathered over more than 50 years on the monitoring of individuals with PKU indicates that a phenylalanine level of about 6 mg/dL (360 µmol/L is ideal and points to the necessity of starting a long-term phenylalanine-restricted diet in which blood phenylalanine level should stay between 2 and 6 mg/dL (120-360 µmol/L. This article aims to establish the general basis for proper monitoring of people with PKU and provide a useful tool for clinicians overseeing treatment. We hope to establish similar criteria throughout Latin America and create a uniform protocol in order to have comparative monitoring results for the region.

  2. Mobile monitoring and embedded control system for factory environment.

    Science.gov (United States)

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  3. Mobile Monitoring and Embedded Control System for Factory Environment

    Science.gov (United States)

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-01-01

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones. PMID:24351642

  4. Mobile Monitoring and Embedded Control System for Factory Environment

    Directory of Open Access Journals (Sweden)

    Kuang-Yow Lian

    2013-12-01

    Full Text Available This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC technology is used to carry out the actual electricity load experiments using smart phones.

  5. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Revised

    Science.gov (United States)

    Fargion, Giulietta S.; Mueller, James L.

    2000-01-01

    The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

  6. Evolutionary implications of genetic code deviations

    International Nuclear Information System (INIS)

    Chela Flores, J.

    1986-07-01

    By extending the standard genetic code into a temperature dependent regime, we propose a train of molecular events leading to alternative coding. The first few examples of these deviations have already been reported in some ciliated protozoans and Gram positive bacteria. A possible range of further alternative coding, still within the context of universality, is pointed out. (author)

  7. Intelligent routing protocol for ad hoc wireless network

    Science.gov (United States)

    Peng, Chaorong; Chen, Chang Wen

    2006-05-01

    A novel routing scheme for mobile ad hoc networks (MANETs), which combines hybrid and multi-inter-routing path properties with a distributed topology discovery route mechanism using control agents is proposed in this paper. In recent years, a variety of hybrid routing protocols for Mobile Ad hoc wireless networks (MANETs) have been developed. Which is proactively maintains routing information for a local neighborhood, while reactively acquiring routes to destinations beyond the global. The hybrid protocol reduces routing discovery latency and the end-to-end delay by providing high connectivity without requiring much of the scarce network capacity. On the other side the hybrid routing protocols in MANETs likes Zone Routing Protocol still need route "re-discover" time when a route between zones link break. Sine the topology update information needs to be broadcast routing request on local zone. Due to this delay, the routing protocol may not be applicable for real-time data and multimedia communication. We utilize the advantages of a clustering organization and multi-routing path in routing protocol to achieve several goals at the same time. Firstly, IRP efficiently saves network bandwidth and reduces route reconstruction time when a routing path fails. The IRP protocol does not require global periodic routing advertisements, local control agents will automatically monitor and repair broke links. Secondly, it efficiently reduces congestion and traffic "bottlenecks" for ClusterHeads in clustering network. Thirdly, it reduces significant overheads associated with maintaining clusters. Fourthly, it improves clusters stability due to dynamic topology changing frequently. In this paper, we present the Intelligent Routing Protocol. First, we discuss the problem of routing in ad hoc networks and the motivation of IRP. We describe the hierarchical architecture of IRP. We describe the routing process and illustrate it with an example. Further, we describe the control manage

  8. Cassandra - D6.3 - final protocol : Seventh Framework Programme THEME Monitoring and Tracking of Shipping Containers Security

    NARCIS (Netherlands)

    Malenstein, J.; Schewe, W.; Zomer, G.; Klievink, A.J.; Nijdam, M.; Visscher, W.

    2014-01-01

    The Cassandra project addressed procedures and methods (protocols) for government supervision of international trade lanes. Specifically, it looked at the impact of the Cassandra innovations on the procedures and methods to assess risks (risk assessment protocols). This covers the way in which the

  9. Silanization of silica and glass slides for DNA microarrays by impregnation and gas phase protocols: A comparative study

    International Nuclear Information System (INIS)

    Phaner-Goutorbe, Magali; Dugas, Vincent; Chevolot, Yann; Souteyrand, Eliane

    2011-01-01

    Surface immobilization of oligonucleotide probes (oligoprobes) is a key issue in the development of DNA-chips. The immobilization protocol should guarantee good availability of the probes, low non-specific adsorption and reproducibility. We have previously reported a silanization protocol with tert-butyl-11-(dimethylamino)silylundecanoate performed by impregnation (Impregnation Protocol, IP) of silica substrates from dilute silane solutions, leading to surfaces bearing carboxylic groups. In this paper, the Impregnation protocol is compared with a Gas phase Protocol (GP) which is more suited to industrial requirements such as reliable and robust processing, cost efficiency, etc.... The morphology of the oligoprobe films at the nanoscale (characterized by Atomic Force Microscopy) and the reproducibility of subsequent oligoprobes immobilization steps have been investigated for the two protocols on thermal silica (Si/SiO 2 ) and glass slide substrates. IP leads to smooth surfaces whereas GP induces the formation of islands features suggesting a non-continuous silane layer. The reproducibility of the overall surface layer (18.75 mm 2 ) has been evaluated through the covalent immobilization of a fluorescent oligoprobes. Average fluorescent signals of 6 (a.u.) and 4 (a.u.) were observed for IP and GP, respectively, with a standard deviation of 1 for both protocols. Thus, despite a morphological difference of the silane layer at the nanometer scale, the density of the immobilized probes remained similar.

  10. Full-field transmission-type angle-deviation optical microscope with reflectivity-height transformation.

    Science.gov (United States)

    Chiu, Ming-Hung; Tan, Chen-Tai; Tsai, Ming-Hung; Yang, Ya-Hsin

    2015-10-01

    This full-field transmission-type three-dimensional (3D) optical microscope is constructed based on the angle deviation method (ADM) and the algorithm of reflectivity-height transformation (RHT). The surface height is proportional to the deviation angle of light passing through the object. The angle deviation and surface height can be measured based on the reflectivity closed to the critical angle using a parallelogram prism and two CCDs.

  11. A course on large deviations with an introduction to Gibbs measures

    CERN Document Server

    Rassoul-Agha, Firas

    2015-01-01

    This is an introductory course on the methods of computing asymptotics of probabilities of rare events: the theory of large deviations. The book combines large deviation theory with basic statistical mechanics, namely Gibbs measures with their variational characterization and the phase transition of the Ising model, in a text intended for a one semester or quarter course. The book begins with a straightforward approach to the key ideas and results of large deviation theory in the context of independent identically distributed random variables. This includes Cramér's theorem, relative entropy, Sanov's theorem, process level large deviations, convex duality, and change of measure arguments. Dependence is introduced through the interactions potentials of equilibrium statistical mechanics. The phase transition of the Ising model is proved in two different ways: first in the classical way with the Peierls argument, Dobrushin's uniqueness condition, and correlation inequalities and then a second time through the ...

  12. Targets of operation monitoring

    International Nuclear Information System (INIS)

    Wenger, H.

    1997-01-01

    The condition monitoring system of a nuclear power plant should be an assurance for the user and the authorities that the safety of the installation constantly corresponds to the nominal condition. As soon as deviations from these conditions occur, it should quickly provide fundamentals for corrective measures. It contributes to a high degree of availability of the installation and makes safe and economical operation throughout the whole life of the installation possible. (author) 1 fig

  13. Analysis of form deviation in non-isothermal glass molding

    Science.gov (United States)

    Kreilkamp, H.; Grunwald, T.; Dambon, O.; Klocke, F.

    2018-02-01

    Especially in the market of sensors, LED lighting and medical technologies, there is a growing demand for precise yet low-cost glass optics. This demand poses a major challenge for glass manufacturers who are confronted with the challenge arising from the trend towards ever-higher levels of precision combined with immense pressure on market prices. Since current manufacturing technologies especially grinding and polishing as well as Precision Glass Molding (PGM) are not able to achieve the desired production costs, glass manufacturers are looking for alternative technologies. Non-isothermal Glass Molding (NGM) has been shown to have a big potential for low-cost mass manufacturing of complex glass optics. However, the biggest drawback of this technology at the moment is the limited accuracy of the manufactured glass optics. This research is addressing the specific challenges of non-isothermal glass molding with respect to form deviation of molded glass optics. Based on empirical models, the influencing factors on form deviation in particular form accuracy, waviness and surface roughness will be discussed. A comparison with traditional isothermal glass molding processes (PGM) will point out the specific challenges of non-isothermal process conditions. Furthermore, the underlying physical principle leading to the formation of form deviations will be analyzed in detail with the help of numerical simulation. In this way, this research contributes to a better understanding of form deviations in non-isothermal glass molding and is an important step towards new applications demanding precise yet low-cost glass optics.

  14. A Design of Wireless Sensor Networks for a Power Quality Monitoring System

    Directory of Open Access Journals (Sweden)

    Sanggil Kang

    2010-11-01

    Full Text Available Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  15. A design of wireless sensor networks for a power quality monitoring system.

    Science.gov (United States)

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  16. Monitoring of patients treated with lithium for bipolar disorder: an international survey.

    Science.gov (United States)

    Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W

    2018-04-14

    Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.

  17. Incorporating assumption deviation risk in quantitative risk assessments: A semi-quantitative approach

    International Nuclear Information System (INIS)

    Khorsandi, Jahon; Aven, Terje

    2017-01-01

    Quantitative risk assessments (QRAs) of complex engineering systems are based on numerous assumptions and expert judgments, as there is limited information available for supporting the analysis. In addition to sensitivity analyses, the concept of assumption deviation risk has been suggested as a means for explicitly considering the risk related to inaccuracies and deviations in the assumptions, which can significantly impact the results of the QRAs. However, challenges remain for its practical implementation, considering the number of assumptions and magnitude of deviations to be considered. This paper presents an approach for integrating an assumption deviation risk analysis as part of QRAs. The approach begins with identifying the safety objectives for which the QRA aims to support, and then identifies critical assumptions with respect to ensuring the objectives are met. Key issues addressed include the deviations required to violate the safety objectives, the uncertainties related to the occurrence of such events, and the strength of knowledge supporting the assessments. Three levels of assumptions are considered, which include assumptions related to the system's structural and operational characteristics, the effectiveness of the established barriers, as well as the consequence analysis process. The approach is illustrated for the case of an offshore installation. - Highlights: • An approach for assessing the risk of deviations in QRA assumptions is presented. • Critical deviations and uncertainties related to their occurrence are addressed. • The analysis promotes critical thinking about the foundation and results of QRAs. • The approach is illustrated for the case of an offshore installation.

  18. From Hype to an Operational Tool: Efforts to Establish a Long-Term Monitoring Protocol of Alluvial Sandbars using 'Structure-from-Motion' Photogrammetry

    Science.gov (United States)

    Rossi, R.; Buscombe, D.; Grams, P. E.; Wheaton, J. M.

    2015-12-01

    Despite recent advances in the use of 'Structure-from-Motion' (SfM) photogrammetry to accurately map landforms, its utility for reliably detecting and monitoring geomorphic change from repeat surveys remains underexplored in fluvial environments. It is unclear how the combination of various image acquisition platforms and techniques, survey scales, vegetation cover, and terrain complexities translate into accuracy and precision metrics for SfM-based construction of digital elevation models (DEMs) of fluvial landforms. Although unmanned aerial vehicles offer the potential to rapidly image large areas, they can be relatively costly, require skilled operators, are vulnerable in adverse weather conditions, and often rely on GPS-positioning to improve their stability. This research details image acquisition techniques for an underrepresented SfM platform: the pole-mounted camera. We highlight image acquisition and post-processing limitations of the SfM method for alluvial sandbars (10s to 100s m2) located in Marble and Grand Canyons in a remote, fluvial landscape with limited field access, strong light gradients, highly variable surface texture and limited ground control. We recommend a pole-based SfM protocol and evaluate it by comparing SfM-derived DEMs against concurrent, total station surveys and TLS derived DEMs. Error models of the sandbar surfaces are developed for a variety of surface characteristics (e.g., bare sand, steep slopes, and areas of shadow). The Geomorphic Change Detection (GCD) Software is used to compare SfM DEMs from before and after the 2014 high flow release from Glen Canyon Dam. Complementing existing total-station based sandbar surveys with potentially more efficient and cost-effective SfM methods will contribute to the understanding of morphodynamic responses of sandbars to high flow releases from Glen Canyon Dam. In addition, the development and implementation of a SfM-based operational protocol for monitoring geomorphic change will provide

  19. Interaction Control Protocols for Distributed Multi-user Multi-camera Environments

    Directory of Open Access Journals (Sweden)

    Gareth W Daniel

    2003-10-01

    Full Text Available Video-centred communication (e.g., video conferencing, multimedia online learning, traffic monitoring, and surveillance is becoming a customary activity in our lives. The management of interactions in such an environment is a complicated HCI issue. In this paper, we present our study on a collection of interaction control protocols for distributed multiuser multi-camera environments. These protocols facilitate different approaches to managing a user's entitlement for controlling a particular camera. We describe a web-based system that allows multiple users to manipulate multiple cameras in varying remote locations. The system was developed using the Java framework, and all protocols discussed have been incorporated into the system. Experiments were designed and conducted to evaluate the effectiveness of these protocols, and to enable the identification of various human factors in a distributed multi-user and multi-camera environment. This work provides an insight into the complexity associated with the interaction management in video-centred communication. It can also serve as a conceptual and experimental framework for further research in this area.

  20. Does standard deviation matter? Using "standard deviation" to quantify security of multistage testing.

    Science.gov (United States)

    Wang, Chun; Zheng, Yi; Chang, Hua-Hua

    2014-01-01

    With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.

  1. A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS for Motion Reduction

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-06-01

    Full Text Available This paper presents a comparative study in physiological monitoring between a wearable opto-electronic patch sensor (OEPS comprising a three-axis Microelectromechanical systems (MEMs accelerometer (3MA and commercial devices. The study aims to effectively capture critical physiological parameters, for instance, oxygen saturation, heart rate, respiration rate and heart rate variability, as extracted from the pulsatile waveforms captured by OEPS against motion artefacts when using the commercial probe. The protocol involved 16 healthy subjects and was designed to test the features of OEPS, with emphasis on the effective reduction of motion artefacts through the utilization of a 3MA as a movement reference. The results show significant agreement between the heart rates from the reference measurements and the recovered signals. Significance of standard deviation and error of mean yield values of 2.27 and 0.65 beats per minute, respectively; and a high correlation (0.97 between the results of the commercial sensor and OEPS. T, Wilcoxon and Bland-Altman with 95% limit of agreement tests were also applied in the comparison of heart rates extracted from these sensors, yielding a mean difference (MD: 0.08. The outcome of the present work incites the prospects of OEPS on physiological monitoring during physical activities.

  2. Identification of a research protocol to study orthodontic tooth movement

    Directory of Open Access Journals (Sweden)

    Annalisa Dichicco

    2014-06-01

    Full Text Available Aim: The orthodontic movement is associated with a process of tissue remodeling together with the release of several chemical mediators in periodontal tissues. Each mediator is a potential marker of tooth movement and expresses biological processes as: tissue inflammation and bone remodeling. Different amounts of every mediator are present in several tissues and fluids of the oral cavity. Therefore, there are different methods that allow sampling with several degrees of invasiveness. Chemical mediators are also substances of different molecular nature, and multiple kind of analysis methods allow detection. The purpose of this study was to draft the best research protocol for an optimal study on orthodontic movement efficiency. Methods: An analysis of the international literature have been made, to identify the gold standard of each aspect of the protocol: type of mediator, source and method of sampling and analysis method. Results: From the analysis of the international literature was created an original research protocol for the study and the assessment of the orthodontic movement, by using the biomarkers of the tooth movement. Conclusions: The protocol created is based on the choice of the gold standard of every aspect already analyzed in the literature and in existing protocols for the monitoring of orthodontic tooth movement through the markers of tooth movement. Clinical trials re required for the evaluation and validation of the protocol created.

  3. Precision analysis for standard deviation measurements of immobile single fluorescent molecule images.

    Science.gov (United States)

    DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M

    2010-03-29

    Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.

  4. A correlational study of scoliosis and trunk balance in adult patients with mandibular deviation.

    Directory of Open Access Journals (Sweden)

    Shuncheng Zhou

    Full Text Available Previous studies have confirmed that patients with mandibular deviation often have abnormal morphology of their cervical vertebrae. However, the relationship between mandibular deviation, scoliosis, and trunk balance has not been studied. Currently, mandibular deviation is usually treated as a single pathology, which leads to poor clinical efficiency. We investigated the relationship of spine coronal morphology and trunk balance in adult patients with mandibular deviation, and compared the finding to those in healthy volunteers. 35 adult patients with skeletal mandibular deviation and 10 healthy volunteers underwent anterior X-ray films of the head and posteroanterior X-ray films of the spine. Landmarks and lines were drawn and measured on these films. The axis distance method was used to measure the degree of scoliosis and the balance angle method was used to measure trunk balance. The relationship of mandibular deviation, spine coronal morphology and trunk balance was evaluated with the Pearson correlation method. The spine coronal morphology of patients with mandibular deviation demonstrated an "S" type curve, while a straight line parallel with the gravity line was found in the control group (significant difference, p1°, while the control group had a normal trunk balance (imbalance angle <1°. There was a significant difference between the two groups (p<0.01. The degree of scoliosis and shoulder imbalance correlated with the degree of mandibular deviation, and presented a linear trend. The direction of mandibular deviation was the same as that of the lateral bending of thoracolumbar vertebrae, which was opposite to the direction of lateral bending of cervical vertebrae. Our study shows the degree of mandibular deviation has a high correlation with the degree of scoliosis and trunk imbalance, all the three deformities should be clinically evaluated in the management of mandibular deviation.

  5. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  6. Comparison of monitor units calculated by radiotherapy treatment planning system and an independent monitor unit verification software.

    Science.gov (United States)

    Sellakumar, P; Arun, C; Sanjay, S S; Ramesh, S B

    2011-01-01

    In radiation therapy, the monitor units (MU) needed to deliver a treatment plan are calculated by treatment planning systems (TPS). The essential part of quality assurance is to verify the MU with independent monitor unit calculation to correct any potential errors prior to the start of treatment. In this study, we have compared the MU calculated by TPS and by independent MU verification software. The MU verification software was commissioned and tested for the data integrity to ensure that the correct beam data was considered for MU calculations. The accuracy of the calculations was tested by creating a series of test plans and comparing them with ion chamber measurements. The results show that there is good agreement between the two. The MU difference (MUdiff) between the monitor unit calculations of TPS and independent MU verification system was calculated for 623 fields from 245 patients and was analyzed by treatment site for head & neck, thorax, breast, abdomen and pelvis. The mean MUdiff of -0.838% with a standard deviation of 3.04% was observed for all 623 fields. The site specific standard deviation of MUdiff was as follows: abdomen and pelvis (<1.75%), head & neck (2.5%), thorax (2.32%) and breast (6.01%). The disparities were analyzed and different correction methods were used to reduce the disparity. © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Linear maps preserving maximal deviation and the Jordan structure of quantum systems

    International Nuclear Information System (INIS)

    Hamhalter, Jan

    2012-01-01

    In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only one numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnár.

  8. Deviations in human gut microbiota

    DEFF Research Database (Denmark)

    Casén, C; Vebø, H C; Sekelja, M

    2015-01-01

    microbiome profiling. AIM: To develop and validate a novel diagnostic test using faecal samples to profile the intestinal microbiota and identify and characterise dysbiosis. METHODS: Fifty-four DNA probes targeting ≥300 bacteria on different taxonomic levels were selected based on ability to distinguish......, and potential clinically relevant deviation in the microbiome from normobiosis. This model was tested in different samples from healthy volunteers and IBS and IBD patients (n = 330) to determine the ability to detect dysbiosis. RESULTS: Validation confirms dysbiosis was detected in 73% of IBS patients, 70...

  9. A Secure RFID Tag Authentication Protocol with Privacy Preserving in Telecare Medicine Information System.

    Science.gov (United States)

    Li, Chun-Ta; Weng, Chi-Yao; Lee, Cheng-Chi

    2015-08-01

    Radio Frequency Identification (RFID) based solutions are widely used for providing many healthcare applications include patient monitoring, object traceability, drug administration system and telecare medicine information system (TMIS) etc. In order to reduce malpractices and ensure patient privacy, in 2015, Srivastava et al. proposed a hash based RFID tag authentication protocol in TMIS. Their protocol uses lightweight hash operation and synchronized secret value shared between back-end server and tag, which is more secure and efficient than other related RFID authentication protocols. Unfortunately, in this paper, we demonstrate that Srivastava et al.'s tag authentication protocol has a serious security problem in that an adversary may use the stolen/lost reader to connect to the medical back-end server that store information associated with tagged objects and this privacy damage causing the adversary could reveal medical data obtained from stolen/lost readers in a malicious way. Therefore, we propose a secure and efficient RFID tag authentication protocol to overcome security flaws and improve the system efficiency. Compared with Srivastava et al.'s protocol, the proposed protocol not only inherits the advantages of Srivastava et al.'s authentication protocol for TMIS but also provides better security with high system efficiency.

  10. Implementation of a Rapid, Protocol-based TIA Management Pathway.

    Science.gov (United States)

    Jarhult, Susann J; Howell, Melissa L; Barnaure-Nachbar, Isabelle; Chang, Yuchiao; White, Benjamin A; Amatangelo, Mary; Brown, David F; Singhal, Aneesh B; Schwamm, Lee H; Silverman, Scott B; Goldstein, Joshua N

    2018-03-01

    Our goal was to assess whether use of a standardized clinical protocol improves efficiency for patients who present to the emergency department (ED) with symptoms of transient ischemic attack (TIA). We performed a structured, retrospective, cohort study at a large, urban, tertiary care academic center. In July 2012 this hospital implemented a standardized protocol for patients with suspected TIA. The protocol selected high-risk patients for admission and low/intermediate-risk patients to an ED observation unit for workup. Recommended workup included brain imaging, vascular imaging, cardiac monitoring, and observation. Patients were included if clinical providers determined the need for workup for TIA. We included consecutive patients presenting during a six-month period prior to protocol implementation, and those presenting between 6-12 months after implementation. Outcomes included ED length of stay (LOS), hospital LOS, use of neuroimaging, and 90-day risk of stroke or TIA. From 01/2012 to 06/2012, 130 patients were evaluated for TIA symptoms in the ED, and from 01/2013 to 06/2013, 150 patients. The final diagnosis was TIA or stroke in 45% before vs. 41% after (p=0.18). Following the intervention, the inpatient admission rate decreased from 62% to 24% (pTIA among those with final diagnosis of TIA was 3% for both periods. Implementation of a TIA protocol significantly reduced ED LOS and total hospital LOS.

  11. A hospital-based child and adolescent overweight and obesity treatment protocol transferred into a community healthcare setting

    DEFF Research Database (Denmark)

    Mollerup, Pernille Maria; Gamborg, Michael Orland; Trier, Cæcilie

    2017-01-01

    BACKGROUND: Due to the pandemic of child and adolescent overweight and obesity, improvements in overweight and obesity treatment availability and accessibility are needed. METHODS: In this prospective study, we investigated if reductions in body mass index (BMI) standard deviation scores (SDS......) and waist circumference (WC) would occur during 1.5 years of community-based overweight and obesity treatment based upon an effective hospital-based overweight and obesity treatment protocol, The Children's Obesity Clinics' Treatment protocol. Height, weight, and WC were measured at all consultations...... was invested per child per year. CONCLUSION: BMI SDS and WC were reduced after 1.5 years of treatment. Hence, this community-based overweight and obesity treatment program may help accommodate the need for improvements in treatment availability and accessibility....

  12. 9 CFR 381.308 - Deviations in processing.

    Science.gov (United States)

    2010-01-01

    ...) must be handled according to: (1)(i) A HACCP plan for canned product that addresses hazards associated... (d) of this section. (c) [Reserved] (d) Procedures for handling process deviations where the HACCP... accordance with the following procedures: (a) Emergency stops. (1) When retort jams or breakdowns occur...

  13. Statistical monitoring of linear antenna arrays

    KAUST Repository

    Harrou, Fouzi

    2016-11-03

    The paper concerns the problem of monitoring linear antenna arrays using the generalized likelihood ratio (GLR) test. When an abnormal event (fault) affects an array of antenna elements, the radiation pattern changes and significant deviation from the desired design performance specifications can resulted. In this paper, the detection of faults is addressed from a statistical point of view as a fault detection problem. Specifically, a statistical method rested on the GLR principle is used to detect potential faults in linear arrays. To assess the strength of the GLR-based monitoring scheme, three case studies involving different types of faults were performed. Simulation results clearly shown the effectiveness of the GLR-based fault-detection method to monitor the performance of linear antenna arrays.

  14. The D0 online monitoring and automatic DAQ recovery

    International Nuclear Information System (INIS)

    Haas, A.

    2004-01-01

    The DZERO experiment, located at the Fermi National Accelerator Laboratory, has recently started the Run 2 physics program. The detector upgrade included a new Data Acquisition/Level 3 Trigger system. Part of the design for the DAQ/Trigger system was a new monitoring infrastructure. The monitoring was designed to satisfy real-time requirements with 1-second resolution as well as nonreal-time data. It was also designed to handle a large number of displays without putting undue load on the sources of monitoring information. The resulting protocol is based on XML, is easily extensible, and has spawned a large number of displays, clients, and other applications. It is also one of the few sources of detector performance available outside the Online System's security wall. A tool, based on this system, which provides for auto-recovery of DAQ errors, has been designed. This talk will include a description of the DZERO DAQ/Online monitor server, based on the ACE framework, the protocol, the auto-recovery tool, and several of the unique displays which include an ORACLE-based archiver and numerous GUIs

  15. Deviations from LTE in a stellar atmosphere

    International Nuclear Information System (INIS)

    Kalkofen, W.; Klein, R.I.; Stein, R.F.

    1979-01-01

    Deviations from LTE are investigated in an atmosphere of hydrogen atoms with one bound level, satisfying the equations of radiative, hydrostatic, and statistical equilibrium. The departure coefficient and the kinetic temperature as functions of the frequency dependence of the radiative cross section are studied analytically and numerically. Near the outer boundary of the atmosphere, the departure coefficient b is smaller than unity when the radiative cross section αsub(ν) grows with frequency ν faster than ν 2 ; b exceeds unity otherwise. Far from the boundary the departure coefficient tends to exceed unity for any frequency dependence of αsub(ν). Overpopulation (b > 1) always implies that the kinetic temperature in the statistical equilibrium atmosphere is higher than the temperature in the corresponding LTE atmosphere. Upper and lower bounds on the kinetic temperature are given for an atmosphere with deviations from LTE only in the optically shallow layers when the emergent intensity can be described by a radiation temperature. (author)

  16. Deviations from LTE in a stellar atmosphere

    Science.gov (United States)

    Kalkofen, W.; Klein, R. I.; Stein, R. F.

    1979-01-01

    Deviations for LTE are investigated in an atmosphere of hydrogen atoms with one bound level, satisfying the equations of radiative, hydrostatic, and statistical equilibrium. The departure coefficient and the kinetic temperature as functions of the frequency dependence of the radiative cross section are studied analytically and numerically. Near the outer boundary of the atmosphere, the departure coefficient is smaller than unity when the radiative cross section grows with frequency faster than with the square of frequency; it exceeds unity otherwise. Far from the boundary the departure coefficient tends to exceed unity for any frequency dependence of the radiative cross section. Overpopulation always implies that the kinetic temperature in the statistical-equilibrium atmosphere is higher than the temperature in the corresponding LTE atmosphere. Upper and lower bounds on the kinetic temperature are given for an atmosphere with deviations from LTE only in the optically shallow layers when the emergent intensity can be described by a radiation temperature.

  17. Process Measurement Deviation Analysis for Flow Rate due to Miscalibration

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Eunsuk; Kim, Byung Rae; Jeong, Seog Hwan; Choi, Ji Hye; Shin, Yong Chul; Yun, Jae Hee [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    An analysis was initiated to identify the root cause, and the exemption of high static line pressure correction to differential pressure (DP) transmitters was one of the major deviation factors. Also the miscalibrated DP transmitter range was identified as another major deviation factor. This paper presents considerations to be incorporated in the process flow measurement instrumentation calibration and the analysis results identified that the DP flow transmitter electrical output decreased by 3%. Thereafter, flow rate indication decreased by 1.9% resulting from the high static line pressure correction exemption and measurement range miscalibration. After re-calibration, the flow rate indication increased by 1.9%, which is consistent with the analysis result. This paper presents the brief calibration procedures for Rosemount DP flow transmitter, and analyzes possible three cases of measurement deviation including error and cause. Generally, the DP transmitter is required to be calibrated with precise process input range according to the calibration procedure provided for specific DP transmitter. Especially, in case of the DP transmitter installed in high static line pressure, it is important to correct the high static line pressure effect to avoid the inherent systematic error for Rosemount DP transmitter. Otherwise, failure to notice the correction may lead to indicating deviation from actual value.

  18. Wastewater Biosolid Composting Optimization Based on UV-VNIR Spectroscopy Monitoring.

    Science.gov (United States)

    Temporal-Lara, Beatriz; Melendez-Pastor, Ignacio; Gómez, Ignacio; Navarro-Pedreño, Jose

    2016-11-15

    Conventional wastewater treatment generates large amounts of organic matter-rich sludge that requires adequate treatment to avoid public health and environmental problems. The mixture of wastewater sludge and some bulking agents produces a biosolid to be composted at adequate composting facilities. The composting process is chemically and microbiologically complex and requires an adequate aeration of the biosolid (e.g., with a turner machine) for proper maturation of the compost. Adequate (near) real-time monitoring of the compost maturity process is highly difficult and the operation of composting facilities is not as automatized as other industrial processes. Spectroscopic analysis of compost samples has been successfully employed for compost maturity assessment but the preparation of the solid compost samples is difficult and time-consuming. This manuscript presents a methodology based on a combination of a less time-consuming compost sample preparation and ultraviolet, visible and short-wave near-infrared spectroscopy. Spectroscopic measurements were performed with liquid compost extract instead of solid compost samples. Partial least square (PLS) models were developed to quantify chemical fractions commonly employed for compost maturity assessment. Effective regression models were obtained for total organic matter (residual predictive deviation-RPD = 2.68), humification ratio (RPD = 2.23), total exchangeable carbon (RPD = 2.07) and total organic carbon (RPD = 1.66) with a modular and cost-effective visible and near infrared (VNIR) spectroradiometer. This combination of a less time-consuming compost sample preparation with a versatile sensor system provides an easy-to-implement, efficient and cost-effective protocol for compost maturity assessment and near-real-time monitoring.

  19. Required accuracy and dose thresholds in individual monitoring

    DEFF Research Database (Denmark)

    Christensen, P.; Griffith, R.V.

    1994-01-01

    this uncertainty factor, a value of 21% can be evaluated for the allowable maximum overall standard deviation for dose measurements at dose levels near the annual dose limits increasing to 45% for dose levels at the lower end of the dose range required to be monitored. A method is described for evaluating...... the overall standard deviation of the dosimetry system by combining random and systematic uncertainties in quadrature, and procedures are also given for determining each individual uncertainty connected to the dose measurement. In particular, attention is paid to the evaluation of the combined uncertainty due...... to energy and angular dependencies of the dosemeter. In type testing of personal dosimetry systems, the estimated overall standard deviation of the dosimetry system is the main parameter to be tested. An important characteristic of a personal dosimetry system is its capability of measuring low doses...

  20. Multi-Gateway-Based Energy Holes Avoidance Routing Protocol for WSN

    Directory of Open Access Journals (Sweden)

    Rohini Sharma

    2016-04-01

    Full Text Available In wireless sensor networks (WSNs, efficient energy conservation is required to prolong the lifetime of the network. In this work, we have given emphasis on balanced energy consumption and energy holes avoidance. This paper proposes a multi-gateway-based approach to reduce the transmission distance between the sender and the sink node. The area to be monitored is divided into regions and gateway nodes are deployed at optimal positions. We have designed a transmission scheme, in which sensors in the sink region communicate directly to the sink, sensors in the gateway region communicate directly to the gateway, and sensors in the cluster region transmit their data directly to their respective cluster head which transmits data to the gateway in its region. If the distance between a cluster head and the sink is less than the distance between the cluster head and the gateway node, the cluster head transmits data to the sink instead of the gateway node. We have compared the proposed protocol with Low-Energy Adaptive Clustering Hierarchy (LEACH, Gateway Based Energy Aware Multi-Hop Routing (M-GEAR, and Gateway Based Stable Election Protocol (GSEP protocols. The protocol performs better than other protocols in terms of throughput, stability period, lifetime, residual energy, and the packet transmitted to the sink.

  1. Availability of anesthetic effect monitoring: utilization, intraoperative management and time to extubation in liver transplantation.

    Science.gov (United States)

    Schumann, R; Hudcova, J; Bonney, I; Cepeda, M S

    2010-12-01

    Titration of volatile anesthetics to anesthetic effect monitoring using the bispectral index (BIS) has been shown to decrease anesthetic requirements and facilitate recovery from anesthesia unrelated to liver transplantation (OLT). To determine whether availability of such monitoring influences its utilization pattern and affect anesthetic care and outcomes in OLT, we conducted a retrospective analysis in recipients with and without such monitoring. We evaluated annual BIS utilization over a period of 7 years, and compared 41 BIS-monitored patients to 42 controls. All received an isoflurane/air/oxygen and opioid-based anesthetic with planned postoperative ventilation. Data collection included age, body mass index (BMI), gender, Model for End-stage Liver Disease (MELD) score, and time to extubation (TtE). Mean preanhepatic, anhepatic, and postanhepatic end-tidal isoflurane concentrations were compared, as well as BIS values for each phase of OLT using the Kruskal-Wallis and Wilcoxon signed-rank tests, respectively. The use of anesthetic effect monitoring when available increased steadily from 15% of cases in the first year to almost 93% by year 7. There was no significant difference in age, gender, BMI, MELD, or TtE between groups. The BIS group received less inhalational anesthetic during each phase of OLT compared to the control group. However, this difference was statistically significant only during the anhepatic phase (P = .026), and was clinically not impressive. Within the BIS group, the mean BIS value was 38.74 ± 5.25 (mean ± standard deviation), and there was no difference for the BIS value between different transplant phases. Availability of anesthetic effect monitoring as an optional monitoring tool during OLT results in its increasing utilization by anesthesia care teams over time. However, unless integrated into an intraoperative algorithm and an early extubation protocol for fast tracking of OLT recipients, this utilization does not appear to provide

  2. Contrast monitoring techniques in CT pulmonary angiography: An important and underappreciated contributor to breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, D.P., E-mail: dpmmitchell@gmail.com; Rowan, M., E-mail: mrowan@mater.ie; Loughman, E., E-mail: eloughman@mater.ie; Ridge, C.A., E-mail: cridge@mater.ie; MacMahon, P.J., E-mail: pmacmahon@mater.ie

    2017-01-15

    Objective: The aims of our study were to evaluate the contribution of contrast-monitoring techniques to breast dose in pregnant and non-pregnant women, and to investigate the effect of a reduced peak kilovoltage (kV) monitoring scan protocol on breast dose and Computed Tomography Pulmonary Angiography (CTPA) diagnostic quality. Materials and methods: Single center retrospective study of 221 female patients undergoing a reduced kV 80 kV contrast-monitoring CTPA protocol compared to 281 patients using the conventional 120 kV contrast-monitoring protocol (Siemens Somatom Definition AS + ). 99 pregnant patients analyzed separately. ImPACT dosimetry software was used to calculate dose. Group subsets were evaluated to assess CTPA diagnostic quality. Results: The contrast-monitoring component of a CTPA study constituted 27% of the overall breast dose when using a standard 120 kV protocol compared to only 7% of the overall breast dose in the 80 kV study group. The dose to the breast from the contrast-monitoring component alone was reduced by 79% in the non-pregnant patients (0.36mGy ± 0.37 versus 1.7mGy ± 1.02; p < 0.001), and by 88% in the pregnant population (0.25 mGy ± 0.67 versus 2.24mGy ± 1.61; p < 0.001). There was no statistical difference in CTPA diagnostic quality or timing. Conclusion: Despite a short scan length and relatively small DLP, contrast-monitoring techniques (test-bolus or bolus-tracked) set at 120 kV can account for 27% of the overall breast dose accrued from a CTPA study. By decreasing the kilovoltage of the contrast-monitoring component, a significant reduction in breast dose for pregnant and non-pregnant female patients can be achieved without affecting CTPA quality or timing.

  3. Advantages of heavy metal collars in directional drilling and deviation control

    International Nuclear Information System (INIS)

    Bradley, W.B.; Murphey, C.E.; McLamore, R.T.; Dickson, L.L.

    1976-01-01

    A heavy, stiff-bottom drill collar can substantially improve deviation performance, theoretically increasing penetration rates by 50 to 100 percent in deviation-prone areas. This paper presents the underlying theory, practical charts on performance characteristics, and Shell Development Co.'s experience in fabricating and field testing two depleted-uranium alloy, heavy metal collars

  4. The Analysis of a Deviation of Investment and Corporate Governance

    OpenAIRE

    Shoichi Hisa

    2008-01-01

    Investment of firms is affected by not only fundamentals factors, but liquidity constraint, ownership or corporate structure. Information structure between manager and owner is a significant factor to decide the level of investment, and deviation of investment from optimal condition. The reputation model between manager and owner suggest that the separate of ownership and management may induce the deviation of investment, and indicate that governance structure is important to reduce it. In th...

  5. Energy Monitoring System Berbasis Web

    Directory of Open Access Journals (Sweden)

    Novan Zulkarnain

    2013-12-01

    Full Text Available Government through the Ministry of Energy and Mineral Resources (ESDM encourages the energy savings at whole buildings in Indonesia. Energy Monitoring System (EMS is a web-based solution to monitor energy usage in a building. The research methods used are the analysis, prototype design and testing. EMSconsists of hardware which consists of electrical sensors, temperature-humidity sensor, and a computer. Data on EMS are designed using Modbus protocol, stored in MySQL database application, and displayed on charts through Dashboard on LED TV using PHP programming.

  6. A newly designed radiation therapy protocol in combination with prednisolone as treatment for meningoencephalitis of unknown origin in dogs: a prospective pilot study introducing magnetic resonance spectroscopy as monitor tool.

    Science.gov (United States)

    Beckmann, Katrin; Carrera, Inés; Steffen, Frank; Golini, Lorenzo; Kircher, Patrick R; Schneider, Uwe; Bley, Carla Rohrer

    2015-01-31

    A plethora of treatment options have been described for canine meningoencephalitis of unknown origin (MUO), yet a gold standard has not been established. The aim of this prospective pilot study was to document the effect of a newly designed 30 Gray (Gy) radiation therapy (RT) protocol plus corticosteroids as treatment for focal and multifocal MUO, to monitor clinical and imaging changes during the course of the disease with conventional magnetic resonance imaging (MRI) and proton MR Spectroscopy (H-1 MRS) and to detect the occurrence of radiation related side effects. Six dogs (3 with focal and 3 with multifocal lesions) were included in the study. The RT protocol used consisted of 30 Gy in 10 fractions. The neurological status of all six dogs improved during RT, with 3 of 6 cases returning to a normal condition. One dog was euthanized early during follow-up (dog and improved in 3 dogs and H-1 MRS normalized in 4. In the dog without improvement of the MRI lesions, the N-acetyl aspartate continued to decrease, while choline and creatine concentrations remained stable during that time. This dog was euthanized 18 month after the end of RT due to relapse. One dog was lost to follow up 12 month after completion of RT. The other 3 dogs are still alive at the time of writing. RT with 30 Gy in 10 fractions can provide an additional option for anti-inflammatory treatment of focal and multifocal MUO. The protocol used for treatment monitoring was feasible while no side effects of RT could be observed during the follow up period. Moreover, H-1 MRS could represent a new and non-invasive tool to control the progression of the disease during the treatment course.

  7. Sample-path large deviations in credit risk

    NARCIS (Netherlands)

    Leijdekker, V.J.G.; Mandjes, M.R.H.; Spreij, P.J.C.

    2011-01-01

    The event of large losses plays an important role in credit risk. As these large losses are typically rare, and portfolios usually consist of a large number of positions, large deviation theory is the natural tool to analyze the tail asymptotics of the probabilities involved. We first derive a

  8. Deviations from the O3-NO-NO2 photo-stationary state in Delhi, India

    Science.gov (United States)

    Chate, Dilip M.; Ghude, Sachin D.; Beig, Gurfan; Mahajan, Anoop S.; Jena, Chinmay; Srinivas, Reka; Dahiya, Anita; Kumar, Nandini

    2014-10-01

    A network of air quality and weather monitoring stations was set-up across Delhi, India, under the System of Air quality Forecasting And Research (SAFAR) project. The objective of this network was to enable better understanding of air quality in terms of atmospheric chemistry, emissions and forecasting in Delhi, one of the largest metropolises in the world. In this study, we focus on the O3-NO-NO2-triad Photo Stationary State (PSS), and investigate site-specific deviations in the Leighton Ratio (Φ) during a short period in 2012 (1-31 December). Large variations were observed in the NO ( 1) were also observed occasionally, and these data were used to estimate the total peroxy radical (PO2) mixing ratios. This is the first estimate of PO2 reported for the city of Delhi and compares well with the results in the literature.

  9. Effluent Treatment Facility tritium emissions monitoring

    International Nuclear Information System (INIS)

    Dunn, D.L.

    1991-01-01

    An Environmental Protection Agency (EPA) approved sampling and analysis protocol was developed and executed to verify atmospheric emissions compliance for the new Savannah River Site (SRS) F/H area Effluent Treatment Facility. Sampling equipment was fabricated, installed, and tested at stack monitoring points for filtrable particulate radionuclides, radioactive iodine, and tritium. The only detectable anthropogenic radionuclides released from Effluent Treatment Facility stacks during monitoring were iodine-129 and tritium oxide. This paper only examines the collection and analysis of tritium oxide

  10. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 2: Protocol specification

    Science.gov (United States)

    Mckee, James W.

    1990-01-01

    This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.

  11. Bodily Deviations and Body Image in Adolescence

    Science.gov (United States)

    Vilhjalmsson, Runar; Kristjansdottir, Gudrun; Ward, Dianne S.

    2012-01-01

    Adolescents with unusually sized or shaped bodies may experience ridicule, rejection, or exclusion based on their negatively valued bodily characteristics. Such experiences can have negative consequences for a person's image and evaluation of self. This study focuses on the relationship between bodily deviations and body image and is based on a…

  12. Analyzing Menton Deviation in Posteroanterior Cephalogram in Early Detection of Temporomandibular Disorder

    Directory of Open Access Journals (Sweden)

    Trelia Boel

    2017-01-01

    Full Text Available Introduction. Some clinicians believed that mandibular deviation leads to facial asymmetry and it also had a correlation with temporomandibular disorders (TMDs. Posteroanterior (PA cephalogram was widely reported as a regular record in treating facial asymmetry and craniofacial anomalies. The objective of this study was to analyze the relationship of menton deviation in PA cephalogram with temporomandibular disorders (TMDs symptoms. Materials and Methods. TMJ function was initially screened based on TMD-DI questionnaire. PA cephalogram of volunteer subjects with TMDs (n=37 and without TMDs (n=33 with mean age of 21.61±2.08 years was taken. The menton deviation was measured by the distance (mm from menton point to midsagittal reference (MSR horizontally, using software digitized measurement, and categorized as asymmetric if the value is greater than 3 mm. The prevalence and difference of menton deviation in both groups were evaluated by unpaired t-test. Result. The prevalence of symmetry group showed that 65.9% had no TMDs with mean of 1,815 ± 0,71 mm; in contrast, the prevalence of asymmetry group showed that 95.5% reported TMDs with mean of 3,159 ± 1,053 mm. There was a significant difference of menton deviation to TMDs (p=0.000 in subjects with and without TMDs. Conclusion. There was a significant relationship of menton deviation in PA cephalogram with TMDs based on TMD-DI index.

  13. Why do lesser toes deviate laterally in hallux valgus? A radiographic study.

    Science.gov (United States)

    Roan, Li-Yi; Tanaka, Yasuhito; Taniguchi, Akira; Tomiwa, Kiyonori; Kumai, Tsukasa; Cheng, Yuh-Min

    2015-06-01

    Hallux valgus foot with laterally deviated lesser toes is a complex condition to treat. Ignoring the laterally deviated lesser toes in hallux valgus might result in unsatisfactory foot shape. Without lateral support of the lesser toes, it might increase the risk of recurrence of hallux valgus. We sought to identify associated radiographic findings in patients where lesser toes follow the great toe in hallux valgus and deviate laterally. The weight-bearing, anteroposterior foot radiographs of 24 female hallux valgus feet with laterally deviated lesser toes (group L), 34 female hallux valgus feet with normal lesser toes (group H), and 43 normal female feet (group N) were selected for the study. A 2-dimensional coordinated system was used to analyze the shapes and angles of these feet by converting each dot made on the radiographs onto X and Y coordinates. Diagrams of the feet in each group were drawn for comparison. The hallux valgus angle, lateral deviation angle of the second toe, intermetatarsal angles, toe length, metatarsal length, and metatarsus adductus were calculated according to the coordinates of the corresponding points. The mapping showed the bases of the second, third, and fourth toe in group L shifted laterally away from their corresponding metatarsal head (P hallux valgus angles (P hallux valgus angle, more adducted first metatarsal, and divergent lateral splaying of the lesser metatarsals were associated with lateral deviation of the lesser toes in hallux valgus. Level III, comparative study. © The Author(s) 2015.

  14. Large deviations and portfolio optimization

    Science.gov (United States)

    Sornette, Didier

    Risk control and optimal diversification constitute a major focus in the finance and insurance industries as well as, more or less consciously, in our everyday life. We present a discussion of the characterization of risks and of the optimization of portfolios that starts from a simple illustrative model and ends by a general functional integral formulation. A major item is that risk, usually thought of as one-dimensional in the conventional mean-variance approach, has to be addressed by the full distribution of losses. Furthermore, the time-horizon of the investment is shown to play a major role. We show the importance of accounting for large fluctuations and use the theory of Cramér for large deviations in this context. We first treat a simple model with a single risky asset that exemplifies the distinction between the average return and the typical return and the role of large deviations in multiplicative processes, and the different optimal strategies for the investors depending on their size. We then analyze the case of assets whose price variations are distributed according to exponential laws, a situation that is found to describe daily price variations reasonably well. Several portfolio optimization strategies are presented that aim at controlling large risks. We end by extending the standard mean-variance portfolio optimization theory, first within the quasi-Gaussian approximation and then using a general formulation for non-Gaussian correlated assets in terms of the formalism of functional integrals developed in the field theory of critical phenomena.

  15. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    International Nuclear Information System (INIS)

    Wilson, JM; Samei, E

    2016-01-01

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistency and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient

  16. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, JM [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, NC (United States); Samei, E [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, NC (United States); Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistency and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient

  17. A study on the deviation aspects of the poem “The Eightieth Stage”

    Directory of Open Access Journals (Sweden)

    Soghra Salmaninejad Mehrabadi

    2016-02-01

    Full Text Available Abstract  One of the methods of literature review is addressing the literary forms that deeply attracted formalists’ attention. Formalists emphasizes certain shapes and forms and methods of literary language. In their view, the task of literature and art is not making known but representing the elements in the realm of art. So, for creating an outstanding work, novelty is not just important, but modes of expression can show a new dimension of the world to audience.   Shklovsky raised for the first time the term “de familiarization”. In his opinion, art renews sensory perception and transforms the familiar rules and seemingly enduring structures of reality. He believes defamiliarization is seeing things out of their natural context. According to Leach, the two usual methods to distinguish the general language from the language of arts are rule-increasing and rule-decreasing.   In deviation occurs a resurrection of words and the author creates a double pleasure through language games in contact with the audience. Imagery, music and syntax can produce a kind of defamiliarization.   Akhavan in the poem “The Eightieth Stag e ” has used a variety of deviations. The first is in the name of poetry. In this paper, the norms of lexical, semantic and stylistic in the poem “Eightieth Stage” is checked.   Lexical deviation Sartre says the poet does not use the words, but sometimes words would use the new syntax. Akhavan in the words sometimes making terms such as “mardestan (masculinity, faramoshzar (plains of oblivion, gandomand (Robust, golazin (inflorescence, parhib (deception and ...” and sometimes new compounds alters magically the effect of poetry. His compounds like talaei makhmal avayan (golden voices and velvet, pak ayin (clean rituals, malmalin dastar (silver turban, marde mardestan (men of masculinity, rakhshe rakhshande (the brilliant horse and…" makes illustration that in some of synergistic base has helped to the poet

  18. OBSERVABLE DEVIATIONS FROM HOMOGENEITY IN AN INHOMOGENEOUS UNIVERSE

    Energy Technology Data Exchange (ETDEWEB)

    Giblin, John T. Jr. [Department of Physics, Kenyon College, 201 N College Road Gambier, OH 43022 (United States); Mertens, James B.; Starkman, Glenn D. [CERCA/ISO, Department of Physics, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106 (United States)

    2016-12-20

    How does inhomogeneity affect our interpretation of cosmological observations? It has long been wondered to what extent the observable properties of an inhomogeneous universe differ from those of a corresponding Friedmann–Lemaître–Robertson–Walker (FLRW) model, and how the inhomogeneities affect that correspondence. Here, we use numerical relativity to study the behavior of light beams traversing an inhomogeneous universe, and construct the resulting Hubble diagrams. The universe that emerges exhibits an average FLRW behavior, but inhomogeneous structures contribute to deviations in observables across the observer’s sky. We also investigate the relationship between angular diameter distance and the angular extent of a source, finding deviations that grow with source redshift. These departures from FLRW are important path-dependent effects, with implications for using real observables in an inhomogeneous universe such as our own.

  19. OBSERVABLE DEVIATIONS FROM HOMOGENEITY IN AN INHOMOGENEOUS UNIVERSE

    International Nuclear Information System (INIS)

    Giblin, John T. Jr.; Mertens, James B.; Starkman, Glenn D.

    2016-01-01

    How does inhomogeneity affect our interpretation of cosmological observations? It has long been wondered to what extent the observable properties of an inhomogeneous universe differ from those of a corresponding Friedmann–Lemaître–Robertson–Walker (FLRW) model, and how the inhomogeneities affect that correspondence. Here, we use numerical relativity to study the behavior of light beams traversing an inhomogeneous universe, and construct the resulting Hubble diagrams. The universe that emerges exhibits an average FLRW behavior, but inhomogeneous structures contribute to deviations in observables across the observer’s sky. We also investigate the relationship between angular diameter distance and the angular extent of a source, finding deviations that grow with source redshift. These departures from FLRW are important path-dependent effects, with implications for using real observables in an inhomogeneous universe such as our own.

  20. Monitoring Human Activity through Portable Devices

    Directory of Open Access Journals (Sweden)

    G. Sebestyen

    2012-06-01

    Full Text Available Monitoring human activity may be useful for medical supervision and for prophylactic purposes. Mobile devices like intelligent phones or watches have multiple sensors and wireless communication capabilities which can be used for this purpose. This paper presents some integrated solutions for determining and continuous monitoring of a person’s state. Aspects taken into consideration are: activity detection and recognition based on acceleration sensors, wireless communication protocols for data acquisition, web monitoring, alerts generation and statistical processing of multiple sensorial data. As practical implementations two case studies are presented, one using an intelligent phone and another using a mixed signal processor integrated in a watch.

  1. Validation of the Andon KD-5851 upper arm blood pressure monitor, for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Wu, Lili; Jiao, Yinghui; Wang, Chengdong; Chen, Lei; Di, Dalin; Zhang, Haiyan

    2015-08-01

    This study aimed to validate the Andon KD-5851 upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 33 eligible participants were included in the study. Sequential measurements of BPs were performed using a mercury sphygmomanometer and the device, and the data analysis was carried out following precisely the ESH-IP revision 2010. The device had 82, 98, and 99 measurements within 5, 10, and 15 mmHg for systolic blood pressure and 85, 95, and 99 measurements for diastolic blood pressure, respectively. The average device-observer difference was -0.53±4.00 mmHg for systolic blood pressure and -1.15±4.06 mmHg for diastolic blood pressure. The device passed all the criteria according to the ESH-IP revision 2010. According to the validation results on the basis of the ESH-IP revision 2010, the Andon KD-5851 upper arm BP monitor can be recommended for self/home measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  2. Comparison of low- and ultralow-dose computed tomography protocols for quantitative lung and airway assessment.

    Science.gov (United States)

    Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C

    2017-09-01

    Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction

  3. COAP BASED ACUTE PARKING LOT MONITORING SYSTEM USING SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    R. Aarthi

    2014-06-01

    Full Text Available Vehicle parking is the act of temporarily maneuvering a vehicle in to a certain location. To deal with parking monitoring system issue such as traffic, this paper proposes a vision of improvements in monitoring the vehicles in parking lots based on sensor networks. Most of the existing paper deals with that of the automated parking which is of cluster based and each has its own overheads like high power, less energy efficiency, incompatible size of lots, space. The novel idea in this work is usage of CoAP (Constrained Application Protocol which is recently created by IETF (draft-ietf-core-coap-18, June 28, 2013, CoRE group to develop RESTful application layer protocol for communications within embedded wireless networks. This paper deals with the enhanced CoAP protocol using multi hop flat topology, which makes the acuters feel soothe towards parking vehicles. We aim to minimize the time consumed for finding free parking lot as well as increase the energy efficiency

  4. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol

    Directory of Open Access Journals (Sweden)

    Corina Marilena Cristache

    2017-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Materials and Methods. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Results. Mean (and standard deviation of 3D error at the entry point was 0.798 mm (±0.52, at the implant apex it was 1.17 mm (±0.63, and mean angular deviation was 2.34 (±0.85. A statistically significant reduced 3D error was observed at entry point p=.037, at implant apex p=.008, and also in angular deviation p=.030 in mandible when comparing to maxilla. Conclusions. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  5. 1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...

  6. A deviation display method for visualising data in mobile gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Peder, E-mail: Peder.Kock@med.lu.s [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden); Finck, Robert R. [Swedish Radiation Protection Authority, SE-171 16 Stockholm (Sweden); Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden)

    2010-09-15

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded {sup 137}Cs and {sup 241}Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  7. A deviation display method for visualising data in mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Finck, Robert R.; Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded 137 Cs and 241 Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  8. Deviations from Vegard’s law in ternary III-V alloys

    KAUST Repository

    Murphy, S. T.

    2010-08-03

    Vegard’s law states that, at a constant temperature, the volume of an alloy can be determined from a linear interpolation of its constituent’s volumes. Deviations from this description occur such that volumes are both greater and smaller than the linear relationship would predict. Here we use special quasirandom structures and density functional theory to investigate such deviations for MxN1−xAs ternary alloys, where M and N are group III species (B, Al, Ga, and In). Our simulations predict a tendency, with the exception of AlxGa1−xAs, for the volume of the ternary alloys to be smaller than that determined from the linear interpolation of the volumes of the MAs and BAs binary alloys. Importantly, we establish a simple relationship linking the relative size of the group III atoms in the alloy and the predicted magnitude of the deviation from Vegard’s law.

  9. Routine environmental monitoring schedule, calendar year 1997

    Energy Technology Data Exchange (ETDEWEB)

    Markes, B.M., Westinghouse Hanford

    1996-12-10

    This document provides the Environmental Restorations Contractor (ERC) and the Project Hanford Management Contractor.(PHMC) a schedule in accordance with the WHC-CM-7-5, Environmental Compliance` and BHI- EE-02, Environmental Requirements, of monitoring and sampling routines for the Near-Field Monitoring (NFM) program during calendar year (CY) 1997. Every attempt will be made to consistently follow this schedule; any deviation from this schedule will be documented by an internal memorandum (DSI) explaining the reason for the deviation. The DSI will be issued by the scheduled performing organization and directed to Near-Field Monitoring. The survey frequencies for particular sites are determined by the technical judgment of Near- Field Monitoring and may depend on the site history, radiological status, use, and general conditions. Additional surveys may be requested at irregular frequencies if conditions warrant. All radioactive wastes sites are scheduled to be surveyed at least annually. Any newly discovered wastes sites not documented by this schedule will be included in the revised schedule for CY 1998. The outside perimeter road surveys of 200 East and West Area and the rail survey from the 300 Area to Columbia Center will be performed in the year 2000 per agreement with Department of Energy. Richland Field Office. This schedule does not discuss staffing needs, nor does it list the monitoring equipment to be used in completing specific routines. Personnel performing routines to meet this schedule shall communicate any need for assistance in completing these routines to Radiological Control management and Near-Field Monitoring. After each routine survey is completed, a copy of the survey record, maps, and data sheets will be forwarded to Near-Field Monitoring. These routine surveys will not be considered complete until this documentation is received. At the end of each month, the ERC and PHMC radiological control organizations shall forward a copy of the Routine

  10. Error monitoring issues for common channel signaling

    Science.gov (United States)

    Hou, Victor T.; Kant, Krishna; Ramaswami, V.; Wang, Jonathan L.

    1994-04-01

    Motivated by field data which showed a large number of link changeovers and incidences of link oscillations between in-service and out-of-service states in common channel signaling (CCS) networks, a number of analyses of the link error monitoring procedures in the SS7 protocol were performed by the authors. This paper summarizes the results obtained thus far and include the following: (1) results of an exact analysis of the performance of the error monitoring procedures under both random and bursty errors; (2) a demonstration that there exists a range of error rates within which the error monitoring procedures of SS7 may induce frequent changeovers and changebacks; (3) an analysis of the performance ofthe SS7 level-2 transmission protocol to determine the tolerable error rates within which the delay requirements can be met; (4) a demonstration that the tolerable error rate depends strongly on various link and traffic characteristics, thereby implying that a single set of error monitor parameters will not work well in all situations; (5) some recommendations on a customizable/adaptable scheme of error monitoring with a discussion on their implementability. These issues may be particularly relevant in the presence of anticipated increases in SS7 traffic due to widespread deployment of Advanced Intelligent Network (AIN) and Personal Communications Service (PCS) as well as for developing procedures for high-speed SS7 links currently under consideration by standards bodies.

  11. Protocol Implementation Generator

    DEFF Research Database (Denmark)

    Carvalho Quaresma, Jose Nuno; Probst, Christian W.

    2010-01-01

    Users expect communication systems to guarantee, amongst others, privacy and integrity of their data. These can be ensured by using well-established protocols; the best protocol, however, is useless if not all parties involved in a communication have a correct implementation of the protocol and a...... Generator framework based on the LySatool and a translator from the LySa language into C or Java....... necessary tools. In this paper, we present the Protocol Implementation Generator (PiG), a framework that can be used to add protocol generation to protocol negotiation, or to easily share and implement new protocols throughout a network. PiG enables the sharing, verification, and translation...

  12. Guidelines for radiological monitoring of the environment

    International Nuclear Information System (INIS)

    1990-11-01

    This Standard provides criteria to be used in deciding whether an environmental monitoring program is required for a given nuclear facility. It also sets out a systematic approach to monitoring the environment, which is considered to be outside the facility boundary. It provides guidelines for establishing an environmental program covering sampling and analysis protocols, analytical techniques and sensitivity, statistical treatment of monitoring results, quality assurance, methods for expressing results, and record keeping. The standard applies to the environment of a nuclear facility operating mainly under normal conditions; in addition, certain of these requirements may also apply to situations involving abnormal releases

  13. Accuracy assessment of and 111In quantification protocol using Monte Carlo simulated patients

    International Nuclear Information System (INIS)

    Castillo Lopez, J.; Coca, M. A.; Torres, L. A.; Gomez Facenda, A.

    2013-01-01

    The analyzed protocol showed a tendency to overestimate activity, revealed in the mean difference of -0.3MBq. Still, determined activity was never separated more than 10% from simulated one. Differences between calculated and simulated activity followed a Lorentzian distribution with a correlation coefficient of 0.99. The graphical interface exhibited an average difference of 0.001MBq with a standard deviation of 0.5MBq in relation to reference software. It was implemented and evaluated a methodology to perform quantitative calculations of 1 11In activity using whole body studies. Its application with a proposed graphical interface was also assessed. (Author)

  14. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    International Nuclear Information System (INIS)

    Liu, B.

    2016-01-01

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  15. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B. [Massachusetts General Hospital (United States)

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  16. Allan deviation analysis of financial return series

    Science.gov (United States)

    Hernández-Pérez, R.

    2012-05-01

    We perform a scaling analysis for the return series of different financial assets applying the Allan deviation (ADEV), which is used in the time and frequency metrology to characterize quantitatively the stability of frequency standards since it has demonstrated to be a robust quantity to analyze fluctuations of non-stationary time series for different observation intervals. The data used are opening price daily series for assets from different markets during a time span of around ten years. We found that the ADEV results for the return series at short scales resemble those expected for an uncorrelated series, consistent with the efficient market hypothesis. On the other hand, the ADEV results for absolute return series for short scales (first one or two decades) decrease following approximately a scaling relation up to a point that is different for almost each asset, after which the ADEV deviates from scaling, which suggests that the presence of clustering, long-range dependence and non-stationarity signatures in the series drive the results for large observation intervals.

  17. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  18. Monitoring the impact of the DRG payment system on nursing service context factors in Swiss acute care hospitals: Study protocol

    Science.gov (United States)

    Spirig, Rebecca; Spichiger, Elisabeth; Martin, Jacqueline S.; Frei, Irena Anna; Müller, Marianne; Kleinknecht, Michael

    2014-01-01

    Aims: With this study protocol, a research program is introduced. Its overall aim is to prepare the instruments and to conduct the first monitoring of nursing service context factors at three university and two cantonal hospitals in Switzerland prior to the introduction of the reimbursement system based on Diagnosis Related Groups (DRG) and to further develop a theoretical model as well as a methodology for future monitoring following the introduction of DRGs. Background: DRG was introduced to all acute care hospitals in Switzerland in 2012. In other countries, DRG introduction led to rationing and subsequently to a reduction in nursing care. As result, nursing-sensitive patient outcomes were seriously jeopardised. Switzerland has the opportunity to learn from the consequences experienced by other countries when they introduced DRGs. Their experiences highlight that DRGs influence nursing service context factors such as complexity of nursing care or leadership, which in turn influence nursing-sensitive patient outcomes. For this reason, the monitoring of nursing service context factors needs to be an integral part of the introduction of DRGs. However, most acute care hospitals in Switzerland do not monitor nursing service context data. Nursing managers and hospital executive boards will be in need of this data in the future, in order to distribute resources effectively. Methods/Design: A mixed methods design in the form of a sequential explanatory strategy was chosen. During the preparation phase, starting in spring 2011, instruments were selected and prepared, and the access to patient and nursing data in the hospitals was organized. Following this, online collection of quantitative data was conducted in fall 2011. In summer 2012, qualitative data was gathered using focus group interviews, which helped to describe the processes in more detail. During 2013 and 2014, an integration process is being conducted involving complementing, comparing and contrasting

  19. Monitoring the impact of the DRG payment system on nursing service context factors in Swiss acute care hospitals: Study protocol.

    Science.gov (United States)

    Spirig, Rebecca; Spichiger, Elisabeth; Martin, Jacqueline S; Frei, Irena Anna; Müller, Marianne; Kleinknecht, Michael

    2014-01-01

    With this study protocol, a research program is introduced. Its overall aim is to prepare the instruments and to conduct the first monitoring of nursing service context factors at three university and two cantonal hospitals in Switzerland prior to the introduction of the reimbursement system based on Diagnosis Related Groups (DRG) and to further develop a theoretical model as well as a methodology for future monitoring following the introduction of DRGs. DRG was introduced to all acute care hospitals in Switzerland in 2012. In other countries, DRG introduction led to rationing and subsequently to a reduction in nursing care. As result, nursing-sensitive patient outcomes were seriously jeopardised. Switzerland has the opportunity to learn from the consequences experienced by other countries when they introduced DRGs. Their experiences highlight that DRGs influence nursing service context factors such as complexity of nursing care or leadership, which in turn influence nursing-sensitive patient outcomes. For this reason, the monitoring of nursing service context factors needs to be an integral part of the introduction of DRGs. However, most acute care hospitals in Switzerland do not monitor nursing service context data. Nursing managers and hospital executive boards will be in need of this data in the future, in order to distribute resources effectively. A mixed methods design in the form of a sequential explanatory strategy was chosen. During the preparation phase, starting in spring 2011, instruments were selected and prepared, and the access to patient and nursing data in the hospitals was organized. Following this, online collection of quantitative data was conducted in fall 2011. In summer 2012, qualitative data was gathered using focus group interviews, which helped to describe the processes in more detail. During 2013 and 2014, an integration process is being conducted involving complementing, comparing and contrasting quantitative and qualitative findings

  20. Identifying Effective and Sustainable Measures for Community-Based Environmental Monitoring

    Science.gov (United States)

    McKay, Ariana J.; Johnson, Chris J.

    2017-09-01

    Resource development projects typically result in monitoring programs that fail to fully consider the values and participation of surrounding communities. Also, monitoring protocols for single environmental values can be insufficient for addressing the cumulative impacts of resource development. Community-based environmental monitoring (CBEM) has emerged as a way to meaningfully include local citizens in the decision-making process and assessment of the development of natural resources. Our research explored how to develop effective and sustainable CBEM. Interviews were conducted with staff from 15 CBEM programs established across Canada to identify criteria of what constitutes effective CBEM. Results demonstrate that CBEM offers an effective, locally adapted, and culturally applicable approach to facilitate community participation in natural resource management and to track environmental change. Benefits of CBEM include: locally relevant monitoring protocols, inclusion of cumulative impacts, better informed decision-making, and increased awareness and collaboration amongst community, governments, and proponents. Challenges associated with CBEM are cost, capacity, longevity, distribution of results, and establishing credibility. This research validates the use of CBEM for improving resource management.

  1. Solar radiation pressure and deviations from Keplerian orbits

    Energy Technology Data Exchange (ETDEWEB)

    Kezerashvili, Roman Ya. [Physics Department, New York City College of Technology, the City University of New York, Brooklyn, NY 11201 (United States); Vazquez-Poritz, Justin F. [Physics Department, New York City College of Technology, City University of New York, Brooklyn, NY 11201 (United States)], E-mail: jporitz@gmail.com

    2009-05-04

    Newtonian gravity and general relativity give exactly the same expression for the period of an object in circular orbit around a static central mass. However, when the effects of the curvature of spacetime and solar radiation pressure are considered simultaneously for a solar sail propelled satellite, there is a deviation from Kepler's third law. It is shown that solar radiation pressure affects the period of this satellite in two ways: by effectively decreasing the solar mass, thereby increasing the period, and by enhancing the effects of other phenomena, potentially rendering some of them detectable. In particular, we consider deviations from Keplerian orbits due to spacetime curvature, frame dragging from the rotation of the sun, the oblateness of the sun, a possible net electric charge of the sun, and a very small positive cosmological constant.

  2. Differential processing of melodic, rhythmic and simple tone deviations in musicians--an MEG study.

    Science.gov (United States)

    Lappe, Claudia; Lappe, Markus; Pantev, Christo

    2016-01-01

    Rhythm and melody are two basic characteristics of music. Performing musicians have to pay attention to both, and avoid errors in either aspect of their performance. To investigate the neural processes involved in detecting melodic and rhythmic errors from auditory input we tested musicians on both kinds of deviations in a mismatch negativity (MMN) design. We found that MMN responses to a rhythmic deviation occurred at shorter latencies than MMN responses to a melodic deviation. Beamformer source analysis showed that the melodic deviation activated superior temporal, inferior frontal and superior frontal areas whereas the activation pattern of the rhythmic deviation focused more strongly on inferior and superior parietal areas, in addition to superior temporal cortex. Activation in the supplementary motor area occurred for both types of deviations. We also recorded responses to similar pitch and tempo deviations in a simple, non-musical repetitive tone pattern. In this case, there was no latency difference between the MMNs and cortical activation was smaller and mostly limited to auditory cortex. The results suggest that prediction and error detection of musical stimuli in trained musicians involve a broad cortical network and that rhythmic and melodic errors are processed in partially different cortical streams. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Effect of density deviations of concrete on its attenuation efficiency

    International Nuclear Information System (INIS)

    Szymendera, L.; Wincel, K.; Blociszewski, S.; Kordyasz, D.; Sobolewska, I.

    In the work, the influence of concrete density deviation on shield thickness and total dose ratio outside the reactor shield, has--on the basis of numerical analysis--been considered. It has been noticed the possibility of introducing flexible corrections--without additional shielding calculation--to the design thickness of the shield. It has been also found that in common cases of shield design, where any necessity of minimizing the shield thickness does not exist, the tendency to minimize the value of this deviation is hardly substantiable

  4. Improved iterative oscillation tests for first-order deviating differential equations

    Directory of Open Access Journals (Sweden)

    George E. Chatzarakis

    2018-01-01

    Full Text Available In this paper, improved oscillation conditions are established for the oscillation of all solutions of differential equations with non-monotone deviating arguments and nonnegative coefficients. They lead to a procedure that checks for oscillations by iteratively computing \\(\\lim \\sup\\ and \\(\\lim \\inf\\ on terms recursively defined on the equation's coefficients and deviating argument. This procedure significantly improves all known oscillation criteria. The results and the improvement achieved over the other known conditions are illustrated by two examples, numerically solved in MATLAB.

  5. Lichen elements as pollution indicators: evaluation of methods for large monitoring programmes

    Science.gov (United States)

    Susan Will-Wolf; Sarah Jovan; Michael C. Amacher

    2017-01-01

    Lichen element content is a reliable indicator for relative air pollution load in research and monitoring programmes requiring both efficiency and representation of many sites. We tested the value of costly rigorous field and handling protocols for sample element analysis using five lichen species. No relaxation of rigour was supported; four relaxed protocols generated...

  6. [Roaming through methodology. XXXVIII. Common misconceptions involving standard deviation and standard error

    NARCIS (Netherlands)

    Mokkink, H.G.A.

    2002-01-01

    Standard deviation and standard error have a clear mutual relationship, but at the same time they differ strongly in the type of information they supply. This can lead to confusion and misunderstandings. Standard deviation describes the variability in a sample of measures of a variable, for instance

  7. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Science.gov (United States)

    2010-01-01

    ... deviation alerting system. 121.360 Section 121.360 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Equipment Requirements § 121.360 Ground proximity warning-glide slope deviation alerting system. (a) No... system that meets the performance and environmental standards of TSO-C92 (available from the FAA, 800...

  8. Vertical Protocol Composition

    DEFF Research Database (Denmark)

    Groß, Thomas; Mödersheim, Sebastian Alexander

    2011-01-01

    The security of key exchange and secure channel protocols, such as TLS, has been studied intensively. However, only few works have considered what happens when the established keys are actually used—to run some protocol securely over the established “channel”. We call this a vertical protocol.......e., that the combination cannot introduce attacks that the individual protocols in isolation do not have. In this work, we prove a composability result in the symbolic model that allows for arbitrary vertical composition (including self-composition). It holds for protocols from any suite of channel and application...

  9. SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Och, J [Geisinger Medical Center, Danville, PA (United States)

    2016-06-15

    Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinical Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.

  10. Geometry of river networks. I. Scaling, fluctuations, and deviations

    International Nuclear Information System (INIS)

    Dodds, Peter Sheridan; Rothman, Daniel H.

    2001-01-01

    This paper is the first in a series of three papers investigating the detailed geometry of river networks. Branching networks are a universal structure employed in the distribution and collection of material. Large-scale river networks mark an important class of two-dimensional branching networks, being not only of intrinsic interest but also a pervasive natural phenomenon. In the description of river network structure, scaling laws are uniformly observed. Reported values of scaling exponents vary, suggesting that no unique set of scaling exponents exists. To improve this current understanding of scaling in river networks and to provide a fuller description of branching network structure, here we report a theoretical and empirical study of fluctuations about and deviations from scaling. We examine data for continent-scale river networks such as the Mississippi and the Amazon and draw inspiration from a simple model of directed, random networks. We center our investigations on the scaling of the length of a subbasin's dominant stream with its area, a characterization of basin shape known as Hack's law. We generalize this relationship to a joint probability density, and provide observations and explanations of deviations from scaling. We show that fluctuations about scaling are substantial, and grow with system size. We find strong deviations from scaling at small scales which can be explained by the existence of a linear network structure. At intermediate scales, we find slow drifts in exponent values, indicating that scaling is only approximately obeyed and that universality remains indeterminate. At large scales, we observe a breakdown in scaling due to decreasing sample space and correlations with overall basin shape. The extent of approximate scaling is significantly restricted by these deviations, and will not be improved by increases in network resolution

  11. Secure Authentication for Remote Patient Monitoring with Wireless Medical Sensor Networks.

    Science.gov (United States)

    Hayajneh, Thaier; Mohd, Bassam J; Imran, Muhammad; Almashaqbeh, Ghada; Vasilakos, Athanasios V

    2016-03-24

    There is broad consensus that remote health monitoring will benefit all stakeholders in the healthcare system and that it has the potential to save billions of dollars. Among the major concerns that are preventing the patients from widely adopting this technology are data privacy and security. Wireless Medical Sensor Networks (MSNs) are the building blocks for remote health monitoring systems. This paper helps to identify the most challenging security issues in the existing authentication protocols for remote patient monitoring and presents a lightweight public-key-based authentication protocol for MSNs. In MSNs, the nodes are classified into sensors that report measurements about the human body and actuators that receive commands from the medical staff and perform actions. Authenticating these commands is a critical security issue, as any alteration may lead to serious consequences. The proposed protocol is based on the Rabin authentication algorithm, which is modified in this paper to improve its signature signing process, making it suitable for delay-sensitive MSN applications. To prove the efficiency of the Rabin algorithm, we implemented the algorithm with different hardware settings using Tmote Sky motes and also programmed the algorithm on an FPGA to evaluate its design and performance. Furthermore, the proposed protocol is implemented and tested using the MIRACL (Multiprecision Integer and Rational Arithmetic C/C++) library. The results show that secure, direct, instant and authenticated commands can be delivered from the medical staff to the MSN nodes.

  12. A Note on Standard Deviation and Standard Error

    Science.gov (United States)

    Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth

    2010-01-01

    Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.

  13. Operation monitor for plant equipment

    International Nuclear Information System (INIS)

    Kondo, Tetsufumi; Kanemoto, Shigeru.

    1991-01-01

    In a nuclear power plant, states of each of equipment in the plant are monitored accurately even under such a operation condition that the power is changed. That is, the fundamental idea is based on a model comparison method. A deviation between an output signal upon normal plant state obtained in a forecasting model device and that of the objective equipment in the plant are compared with a predetermined value. The result of the comparison is inputted to an alarm device to alarm the abnormality of the states of the equipment to an operator. The device of the present invention thus constituted can monitor the abnormality of the operation of equipment accurately even under such a condition that a power level fluctuates. As a result, it can remarkably contribute to mitigate operator's monitoring operation under the condition such as during load following operation. (I.S.)

  14. Wireless Intelligent Sensors Management Application Protocol-WISMAP

    Directory of Open Access Journals (Sweden)

    Antonio Jesus Yuste-Delgado

    2010-09-01

    Full Text Available Although many recent studies have focused on the development of new applications for wireless sensor networks, less attention has been paid to knowledge-based sensor nodes. The objective of this work is the development in a real network of a new distributed system in which every sensor node can execute a set of applications, such as fuzzy ruled-base systems, measures, and actions. The sensor software is based on a multi-agent structure that is composed of three components: management, application control, and communication agents; a service interface, which provides applications the abstraction of sensor hardware and other components; and an application layer protocol. The results show the effectiveness of the communication protocol and that the proposed system is suitable for a wide range of applications. As real world applications, this work presents an example of a fuzzy rule-based system and a noise pollution monitoring application that obtains a fuzzy noise indicator.

  15. Industrial wireless sensor networks applications, protocols, and standards

    CERN Document Server

    Güngör, V Çagri

    2013-01-01

    The collaborative nature of industrial wireless sensor networks (IWSNs) brings several advantages over traditional wired industrial monitoring and control systems, including self-organization, rapid deployment, flexibility, and inherent intelligent processing. In this regard, IWSNs play a vital role in creating more reliable, efficient, and productive industrial systems, thus improving companies' competitiveness in the marketplace. Industrial Wireless Sensor Networks: Applications, Protocols, and Standards examines the current state of the art in industrial wireless sensor networks and outline

  16. Relationship and significance of gait deviations associated with limb length discrepancy: A systematic review.

    Science.gov (United States)

    Khamis, Sam; Carmeli, Eli

    2017-09-01

    Controversy still exists as to the clinical significance of leg length discrepancy (LLD) in spite of the fact that further evidence has been emerging regarding the relationship between several clinical conditions and LLD. The objectives of our study were to review the available research with regard to LLD as a cause of clinically significant gait deviations, to determine if there is a relationship between the magnitude of LLD and the presence of gait deviations and to identify the most common gait deviations associated with LLD. In line with the PRISMA guidelines, a literature search was carried out throughout the Medline, CINAHL and EMBASE databases. Twelve articles met the predetermined inclusion criteria and were included in the review. Quality assessment using the Methodological Index for Non-Randomized Studies (MINORS) scale was completed for all included studies. Two main methodologies were found in 4 studies evaluating gait asymmetry in patients or healthy participants with anatomic LLD and 8 studies evaluating gait deviations while simulating LLD by employing artificial lifts of 1-5cm on healthy subjects. A significant relationship was found between anatomic LLD and gait deviation. Evidence suggests that gait deviations may occur with discrepancies of >1cm, with greater impact seen as the discrepancy increases. Compensatory strategies were found to occur in both the shorter and longer limb, throughout the lower limb. As the discrepancy increases, more compensatory strategies occur. Sagittal plane deviations seem to be the most effective deviations, although, frontal plane compensations also occur in the pelvis, hip and foot. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. 40 CFR 60.2780 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and... the deviation report? In each report required under § 60.2775, for any pollutant or parameter that...

  18. 40 CFR 60.2958 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Operator Training and Qualification Recordkeeping and Reporting § 60.2958 What must I include in the deviation report? In each report...

  19. Ocean fertilization, carbon credits and the Kyoto Protocol

    Science.gov (United States)

    Westley, M. B.; Gnanadesikan, A.

    2008-12-01

    Commercial interest in ocean fertilization as a carbon sequestration tool was excited by the December 1997 agreement of the Kyoto Protocol to the United Nations Convention on Climate Change. The Protocol commits industrialized countries to caps on net greenhouse gas emissions and allows for various flexible mechanisms to achieve these caps in the most economically efficient manner possible, including trade in carbon credits from projects that reduce emissions or enhance sinks. The carbon market was valued at 64 billion in 2007, with the bulk of the trading (50 billion) taking place in the highly regulated European Union Emission Trading Scheme, which deals primarily in emission allowances in the energy sector. A much smaller amount, worth $265 million, was traded in the largely unregulated "voluntary" market (Capoor and Ambrosi 2008). As the voluntary market grows, so do calls for its regulation, with several efforts underway to set rules and standards for the sale of voluntary carbon credits using the Kyoto Protocol as a starting point. Four US-based companies and an Australian company currently seek to develop ocean fertilization technologies for the generation of carbon credits. We review these plans through the lens of the Kyoto Protocol and its flexible mechanisms, and examine whether and how ocean fertilization could generate tradable carbon credits. We note that at present, ocean sinks are not included in the Kyoto Protocol, and that furthermore, the Kyoto Protocol only addresses sources and sinks of greenhouse gases within national boundaries, making open-ocean fertilization projects a jurisdictional challenge. We discuss the negotiating history behind the limited inclusion of land use, land use change and forestry in the Kyoto Protocol and the controversy and eventual compromise concerning methodologies for terrestrial carbon accounting. We conclude that current technologies for measuring and monitoring carbon sequestration following ocean fertilization

  20. Validation of a real-time wireless telemedicine system, using bluetooth protocol and a mobile phone, for remote monitoring patient in medical practice.

    Science.gov (United States)

    Yousef, Jasemian; Lars, A N

    2005-06-22

    This paper validates the integration of a generic real-time wireless telemedicine system utilising Global System for Mobile Communications (GSM), BLUETOOTH protocol and General Packet Radio Service (GPRS) for cellular network in clinical practice. In the first experiment, the system was tested on 24 pacemaker patients at Aalborg Hospital (Denmark), in order to see if the pacemaker implant would be affected by the system. I the second experiment, the system was tested on 15 non risky arrhythmia heart patients, in order to evaluate and validate the system application in clinical practice, for patient monitoring. Electrocardiograms were selected as the continuously monitored parameter in the present study. The results showed that the system had no negative effects on the pacemaker implants. The experiment results showed, that in a realistic environment for the patients, the system had 96.1 % up-time, 3.2 (kbps) throughput, 10(-3) (packet/s) Packet Error Rate and 10(-3) (packet/s) Packet Lost Rate. During 24 hours test the network did not respond for 57 minutes, from which 83.1 % was in the range of 0-3 minutes, 15.4 % was in the range of 3-5 minutes, and only 0.7 % of the down-time was > or = 5 and < or = 6 minutes. By a subjective evaluation, it was demonstrated that the system is applicable and the patients as well as the healthcare personals were highly confident with the system. Moreover, the patients had high degree of mobility and freedom, employing the system. In conclusion, this generic telemedicine system showed a high reliability, quality and performance, and the design can provide a basic principle for real-time wireless remote monitoring systems used in clinical practice.

  1. FEMORAL NECK FRACTURES GARDEN I AND II: EVALUATION OF THE DEVIATION IN LATERAL VIEW.

    Science.gov (United States)

    Leonhardt, Natália Zalc; Melo, Lucas da Ponte; Nordon, David Gonçalves; Silva, Fernando Brandão de Andrade E; Kojima, Kodi Edson; Silva, Jorge Santos

    2017-01-01

    To evaluate the rate of deviation in the lateral radiographic incidence in patients with femoral neck fracture classified as non-diverted in the anteroposterior view (Garden I and II). Nineteen selected patients with femoral neck fractures classified as Garden I and II were retrospectively evaluated, estimating the degree of deviation in the lateral view. Fifteen cases (79%) presented deviations in lateral view, with a mean of 18.6 degrees (±15.5). Most fractures of the femoral neck classified as Garden I and II present some degree of posterior deviation in the X-ray lateral view. Level of Evidence III, Retrospective Comparative Study.

  2. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  3. Neural networks for the monitoring of rotating machinery

    International Nuclear Information System (INIS)

    Alguindigue, I.E.; Loskiewicz-Buczak

    1991-01-01

    Vibration monitoring of components in engineering systems and plants involves the collection of vibration data and detailed analysis to detect features which reflect the operational state of the machinery. The analysis leads to the identification of potential failures and their causes, and makes it possible to perform efficient preventive maintenance. This paper describes a methodology for the automation of some of the activities related to motion and vibration monitoring in these systems. The technique involves training a neural network to model the inter- relationship between signals from two related sensors mounted on an engineering system or component at a time when it is known to be operating properly. Then one signal (or its characteristics) is put into the neural network model to predict the second signal (or its characteristics). This predicted signal is continuously compared with the actual signal A deviation between the predicted and actual signal indicates a changing relationship, usually failure of the component or system. This deviation may be quantified and provides meaningful information about the degree of degradation and deterioration of the component

  4. Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru

    2015-04-01

    The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.

  5. Method for solving fully fuzzy linear programming problems using deviation degree measure

    Institute of Scientific and Technical Information of China (English)

    Haifang Cheng; Weilai Huang; Jianhu Cai

    2013-01-01

    A new ful y fuzzy linear programming (FFLP) prob-lem with fuzzy equality constraints is discussed. Using deviation degree measures, the FFLP problem is transformed into a crispδ-parametric linear programming (LP) problem. Giving the value of deviation degree in each constraint, the δ-fuzzy optimal so-lution of the FFLP problem can be obtained by solving this LP problem. An algorithm is also proposed to find a balance-fuzzy optimal solution between two goals in conflict: to improve the va-lues of the objective function and to decrease the values of the deviation degrees. A numerical example is solved to il ustrate the proposed method.

  6. Protocol for a feasibility randomised controlled trial of the use of Physical ACtivity monitors in an Exercise Referral Setting: the PACERS study.

    Science.gov (United States)

    Hawkins, Jemma; Edwards, Michelle; Charles, Joanna; Jago, Russell; Kelson, Mark; Morgan, Kelly; Murphy, Simon; Oliver, Emily; Simpson, Sharon; Edwards, Rhiannon Tudor; Moore, Graham

    2017-01-01

    Exercise referral schemes are recommended by the National Institute for Clinical Excellence (NICE) for physical activity promotion among inactive patients with health conditions or risk factors. Whilst there is evidence for the initial effectiveness and cost-effectiveness of such schemes for increasing physical activity, evidence of long-term effects is limited. Techniques such as goal setting, self-monitoring and personalised feedback may support motivation for physical activity. Technologies such as activity monitoring devices provide an opportunity to enhance delivery of motivational techniques. This paper describes the PACERS study protocol, which aims to assess the feasibility and acceptability of implementing an activity monitor within the existing Welsh National Exercise Referral Scheme (NERS) and proposed evaluation methodology for a full-scale randomised controlled trial. The PACERS study consists of a pilot randomised controlled trial, process evaluation and exploratory economic analyses. Participants will be recruited from the generic pathway of the Welsh NERS and will be randomly assigned to receive the intervention or usual practice. Usual practice is a 16-week structured exercise programme; the intervention consists of an accelerometry-based activity monitor (MyWellnessKey) and an associated web platform (MyWellnessCloud). The primary outcomes are predefined progression criteria assessing the acceptability and feasibility of the intervention and feasibility of the proposed evaluation methodology. Postal questionnaires will be completed at baseline (time 0: T0), 16 weeks after T0 (T1) and 12 months after T0 (T2). Routinely collected data will also be accessed at the same time points. A sub-sample of intervention participants and exercise referral staff will be interviewed following initiation of intervention delivery and at the end of the study. The PACERS study seeks to assess the feasibility of adding a novel motivational component to an existing

  7. Validation of the Tensoval Duo Control II blood pressure monitor for clinic use and self-measurement according to the British Hypertension Society protocol and the European Society of Hypertension International Protocol Revision 2010.

    Science.gov (United States)

    de Greeff, Annemarie; Shennan, Andrew H

    2013-06-01

    The Tensoval Duo Control II is an automated upper arm device that uses a combination of oscillometric and auscultatory technology to determine blood pressure noninvasively. The accuracy of this device was assessed according to the British Hypertension Society (BHS) protocol and the European Society of Hypertension International Protocol revision 2010 (ESH-IP2) in an adult population. Ethical approval was obtained. Eighty-five and 33 adult individuals, respectively, were recruited to fulfil the requirements of each protocol. Trained observers took nine sequential same-arm measurements alternating between a mercury sphygmomanometer and the device. The device had to achieve at least a B grade for both systolic and diastolic pressures to pass the BHS protocol and had to fulfil the criteria of all three phases of the ESH-IP2 protocol to receive recommendation. The device achieved an A/A grading for the BHS protocol and passed all three phases of the ESH-IP2 protocol. The mean difference±SD for the BHS/ESH protocols, respectively, was -1.8±6.5/-0.7±5.7 mmHg for systolic pressure and 1.9±5.1/2.4±4.5 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low-pressure, medium-pressure and high-pressure ranges. The Tensoval Duo Control II device is recommended for clinical and home use according to both the BHS and the ESH-IP2 standard.

  8. 40 CFR 60.2220 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for... Recordkeeping and Reporting § 60.2220 What must I include in the deviation report? In each report required under...

  9. 40 CFR 60.3053 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance... Model Rule-Recordkeeping and Reporting § 60.3053 What must I include in the deviation report? In each...

  10. Performance Improvement Based Authentication Protocol for Intervessel Traffic Service Data Exchange Format Protocol Based on U-Navigation System in WoT Environment

    Directory of Open Access Journals (Sweden)

    Byunggil Lee

    2014-01-01

    Full Text Available International Association of Lighthouse Authorities (IALA is developing the standard intersystem VTS exchange format (IVEF protocol for exchange of navigation and vessel information between VTS systems and between VTS and vessels. VTS (vessel traffic system is an important marine traffic monitoring system which is designed to improve the safety and efficiency of navigation and the protection of the marine environment. And the demand of Inter-VTS networking has been increased for realization of e-Navigation as shore side collaboration for maritime safety. And IVEF (inter-VTS data exchange format for inter-VTS network has become a hot research topic of VTS system. Currently, the IVEF developed by the International Association of Lighthouse Authorities (IALA does not include any highly trusted certification technology for the connectors. The output of standardization is distributed as the IALA recommendation V-145, and the protocol is implemented with an open source. The IVEF open source, however, is the code used to check the functions of standard protocols. It is too slow to be used in the field and requires a large memory. And the vessel traffic information requires high security since it is highly protected by the countries. Therefore, this paper suggests the authentication protocol to increase the security of the VTS systems using the main certification server and IVEF.

  11. Hazards and preventive measures of well deviation in well construction of in-situ leaching

    International Nuclear Information System (INIS)

    Zou Wenjie; Chen Shihe

    2006-01-01

    Whether the in-situ leaching method is successful depends on the quality of borehole engineering to a great extent. There are lots of factors that affect the quality, and the well deviation is one of notable problems. The hazards and causes of the well deviation are analyzed. The preventive measures and the methods of rectifying the deviation are put forward. (authors)

  12. Connecting Smartphone and Wearable Fitness Tracker Data with a Nationally Used Electronic Health Record System for Diabetes Education to Facilitate Behavioral Goal Monitoring in Diabetes Care: Protocol for a Pragmatic Multi-Site Randomized Trial.

    Science.gov (United States)

    Wang, Jing; Coleman, Deidra Carroll; Kanter, Justin; Ummer, Brad; Siminerio, Linda

    2018-04-02

    Mobile and wearable technology have been shown to be effective in improving diabetes self-management; however, integrating data from these technologies into clinical diabetes care to facilitate behavioral goal monitoring has not been explored. The objective of this paper is to report on a study protocol for a pragmatic multi-site trial along with the intervention components, including the detailed connected health interface. This interface was developed to integrate patient self-monitoring data collected from a wearable fitness tracker and its companion smartphone app to an electronic health record system for diabetes self-management education and support (DSMES) to facilitate behavioral goal monitoring. A 3-month multi-site pragmatic clinical trial was conducted with eligible patients with diabetes mellitus from DSMES programs. The Chronicle Diabetes system is currently freely available to diabetes educators through American Diabetes Association-recognized DSMES programs to set patient nutrition and physical activity goals. To integrate the goal-setting and self-monitoring intervention into the DSMES process, a connected interface in the Chronicle Diabetes system was developed. With the connected interface, patient self-monitoring information collected from smartphones and wearable fitness trackers can facilitate educators' monitoring of patients' adherence to their goals. Feasibility outcomes of the 3-month trial included hemoglobin A 1c levels, weight, and the usability of the connected system. An interface designed to connect data from a wearable fitness tracker with a companion smartphone app for nutrition and physical activity self-monitoring into a diabetes education electronic health record system was successfully developed to enable diabetes educators to facilitate goal setting and monitoring. A total of 60 eligible patients with type 2 diabetes mellitus were randomized into either group 1) standard diabetes education or 2) standard education enhanced with

  13. Micro-computed tomography derived anisotropy detects tumor provoked deviations in bone in an orthotopic osteosarcoma murine model.

    Directory of Open Access Journals (Sweden)

    Heather A Cole

    Full Text Available Radiographic imaging plays a crucial role in the diagnosis of osteosarcoma. Currently, computed-tomography (CT is used to measure tumor-induced osteolysis as a marker for tumor growth by monitoring the bone fractional volume. As most tumors primarily induce osteolysis, lower bone fractional volume has been found to correlate with tumor aggressiveness. However, osteosarcoma is an exception as it induces osteolysis and produces mineralized osteoid simultaneously. Given that competent bone is highly anisotropic (systematic variance in its architectural order renders its physical properties dependent on direction of load and that tumor induced osteolysis and osteogenesis are structurally disorganized relative to competent bone, we hypothesized that μCT-derived measures of anisotropy could be used to qualitatively and quantitatively detect osteosarcoma provoked deviations in bone, both osteolysis and osteogenesis, in vivo. We tested this hypothesis in a murine model of osteosarcoma cells orthotopically injected into the tibia. We demonstrate that, in addition to bone fractional volume, μCT-derived measure of anisotropy is a complete and accurate method to monitor osteosarcoma-induced osteolysis. Additionally, we found that unlike bone fractional volume, anisotropy could also detect tumor-induced osteogenesis. These findings suggest that monitoring tumor-induced changes in the structural property isotropy of the invaded bone may represent a novel means of diagnosing primary and metastatic bone tumors.

  14. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    Science.gov (United States)

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  15. Split Course Hyperfractionated Accelerated Radio-Chemotherapy (SCHARC for patients with advanced head and neck cancer: Influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis

    Directory of Open Access Journals (Sweden)

    Sprague Lisa D

    2006-12-01

    Full Text Available Abstract Background The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol "SCHARC" and the overall survival of our patients. Methods From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %, one third with tongue and floor of mouth tumors (29 % and one fifth (19 % suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1–5: 20 mg/m2/d DDP + 750–1000 mg/m2/d 5FU (cont. infusion. This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69–70.5 Gy. All patients assigned to this scheme were included in the survival evaluation. Results Forty patients (63 % received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d and the median follow up was 1.9 years (678 d, respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 % had acute grade 2–3 mucositis, and 33 patients (58 % suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient 10.5 g/dl and for patients who completed the protocol. Conclusion The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led to long-term disease control and survival in about 50 % of the patients with significant but acceptable toxicity. Most patients

  16. Split Course Hyperfractionated Accelerated Radio-Chemotherapy (SCHARC) for patients with advanced head and neck cancer: Influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis

    International Nuclear Information System (INIS)

    Stadler, Peter; Putnik, Kurt; Kreimeyer, Thore; Sprague, Lisa D; Koelbl, Oliver; Schäfer, Christof

    2006-01-01

    The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol 'SCHARC' and the overall survival of our patients. From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III) were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %), one third with tongue and floor of mouth tumors (29 %) and one fifth (19 %) suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1–5: 20 mg/m 2 /d DDP + 750–1000 mg/m 2 /d 5FU (cont. infusion). This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69–70.5 Gy). All patients assigned to this scheme were included in the survival evaluation. Forty patients (63 %) received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d) and the median follow up was 1.9 years (678 d), respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 %) had acute grade 2–3 mucositis, and 33 patients (58 %) suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient < 1.0 g/nl) and the mean hemoglobin value decreased from 13.2 to 10.5 g/dl. Univariate analysis of survival showed a better outcome for patients with a hemoglobin nadir >10.5 g/dl and for patients who completed the protocol. The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led

  17. Split course hyperfractionated accelerated radio-chemotherapy (SCHARC) for patients with advanced head and neck cancer: influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis.

    Science.gov (United States)

    Stadler, Peter; Putnik, Kurt; Kreimeyer, Thore; Sprague, Lisa D; Koelbl, Oliver; Schäfer, Christof

    2006-12-07

    The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol "SCHARC" and the overall survival of our patients. From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III) were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %), one third with tongue and floor of mouth tumors (29 %) and one fifth (19 %) suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1-5: 20 mg/m2/d DDP + 750-1000 mg/m2/d 5FU (cont. infusion). This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69-70.5 Gy). All patients assigned to this scheme were included in the survival evaluation. Forty patients (63 %) received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d) and the median follow up was 1.9 years (678 d), respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 %) had acute grade 2-3 mucositis, and 33 patients (58 %) suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient hemoglobin value decreased from 13.2 to 10.5 g/dl. Univariate analysis of survival showed a better outcome for patients with a hemoglobin nadir >10.5 g/dl and for patients who completed the protocol. The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led to long-term disease control and survival in

  18. The significance of sampling time in therapeutic drug monitoring of clozapine

    DEFF Research Database (Denmark)

    Jakobsen, M I; Larsen, J R; Svensson, C K

    2017-01-01

    OBJECTIVE: Therapeutic drug monitoring (TDM) of clozapine is standardized to 12-h postdose samplings. In clinical settings, sampling time often deviates from this time point, although the importance of the deviation is unknown. To this end, serum concentrations (s-) of clozapine and its metabolite...... N-desmethyl-clozapine (norclozapine) were measured at 12 ± 1 and 2 h postdose. METHOD: Forty-six patients with a diagnosis of schizophrenia, and on stable clozapine treatment, were enrolled for hourly, venous blood sampling at 10-14 h postdose. RESULTS: Minor changes in median percentage values were...

  19. A two-shift optimisation of the 'no action level' setup correction protocol

    International Nuclear Information System (INIS)

    Fox, C.; Fisher, R.

    2004-01-01

    Full text: As electronic portal imaging equipment becomes more common, many radiotherapy centres now have the ability to collect patient treatment position deviation values. One commonly used off-line set-up correction protocol for calculating patient setup corrections is the 'no action level' (NAL) protocol. This paper proposes a two-shift approach and calculates the number of images required for minimum systematic error. Patient data is used in a simulation to confirm this approach. Patient treatment position deviations were available for all treatment sessions for a large group of patients undergoing radiation therapy for prostate. Thirty of these patients were selected. The patient position at treatment and all isocentre shifts made were recorded in the treatment notes. These were used to simulate the effect of the NAL protocol using a range of image numbers as the basis of the set-up correction. As Bortfeld et al noted, there is an error minimum that can be observed beyond which the mean radial systematic set-up error increases slowly with an increase in the number of images used. An enhancement to the NAL was proposed in which the patient's position is corrected on two occasions; once early in the treatment schedule, and again after more images have been collected. The expectation value of the set-up error for this two-shift NAL was found and minimised. The optimum staging for the two-shift NAL for the prostate patients was to image for a total of 9 sessions and to shift the patient after 3 sessions and 9 sessions. The thirty patients showed an uncorrected mean radial setup error of 0.65cm. In this simulation this was corrected to 0.26cm by application of the NAL using 5 images and to 0.17 cm using the two shift NAL with shifts after three and nine images. In situations where staff can manage the workload of collecting and analysing portal images for nine sessions for each patient, the two-shift NAL will result in a high level of set-up accuracy. Copyright

  20. Evaluation of new and conventional thermoluminescent phosphors for environmental monitoring using automated thermoluminescent dosimeter readers

    International Nuclear Information System (INIS)

    Rathbone, B.A.; Endres, A.W.; Antonio, E.J.

    1994-10-01

    In recent years, there has been considerable interest in a new generation of super-sensitive thermoluminescent (TL) phosphors for potential use in routine personnel and environmental monitoring. Two of these phosphors, α-Al 2 O 3 :C and LiF:Mg,Cu,P, are evaluated in this paper for selected characteristics relevant to environmental monitoring, along with two conventional phosphors widely used in environmental monitoring, LiF:Mg,Ti and CaF 2 :Dy. The characteristics evaluated are light-induced fading, light-induced background, linearity and variability at low dose, and the minimum measurable dose. These characteristics were determined using an automated commercial dosimetry system (Harshaw System 8800) and routine processing protocols. Annealing and readout protocols for each phosphor were optimized for use in a large-scale environmental monitoring program