WorldWideScience

Sample records for moderate auxotonic load

  1. Working memory load moderates late attentional bias in social anxiety.

    Science.gov (United States)

    Judah, Matt R; Grant, DeMond M; Lechner, William V; Mills, Adam C

    2013-01-01

    The vigilance-avoidance hypothesis suggests that socially anxious individuals attempt to detect signs that they are being evaluated (vigilance) and subsequently direct attention away from such stimuli (avoidance). Although extensive evidence supports vigilance, data concerning subsequent avoidance is equivocal. Drawing from models of attention, the current study hypothesised that working memory load moderates late attentional bias in social anxiety such that avoidance occurs if working memory load is low, and difficulty disengaging attention occurs if working memory load is high. Forty-one undergraduates (19 socially anxious; 22 non-anxious controls) completed a dot-probe task with emotional (happy and disgust) and neutral facial expressions and a concurrent n-back task. Results supported the hypothesis such that socially anxious subjects demonstrated avoidance of disgust faces when working memory load was absent, but had difficulty disengaging attention during high working memory load. Theoretical implications and directions for future research are discussed.

  2. On the use of lifting surface theory for moderately and heavily loaded ship propellers

    NARCIS (Netherlands)

    Van Gent, W.

    1977-01-01

    It is usual to subdivide the loading range of a ship propeller, in which it developes a thrust in the direction of advance, into light, moderate and heavy loadings. The division is based on the degree to which the flow is influenced by the action of the propeller. For the heavily loaded propeller no

  3. Auxotonic to isometric contraction transitioning in a beating heart causes myosin step-size to down shift.

    Directory of Open Access Journals (Sweden)

    Thomas P Burghardt

    Full Text Available Myosin motors in cardiac ventriculum convert ATP free energy to the work of moving blood volume under pressure. The actin bound motor cyclically rotates its lever-arm/light-chain complex linking motor generated torque to the myosin filament backbone and translating actin against resisting force. Previous research showed that the unloaded in vitro motor is described with high precision by single molecule mechanical characteristics including unitary step-sizes of approximately 3, 5, and 8 nm and their relative step-frequencies of approximately 13, 50, and 37%. The 3 and 8 nm unitary step-sizes are dependent on myosin essential light chain (ELC N-terminus actin binding. Step-size and step-frequency quantitation specifies in vitro motor function including duty-ratio, power, and strain sensitivity metrics. In vivo, motors integrated into the muscle sarcomere form the more complex and hierarchically functioning muscle machine. The goal of the research reported here is to measure single myosin step-size and step-frequency in vivo to assess how tissue integration impacts motor function. A photoactivatable GFP tags the ventriculum myosin lever-arm/light-chain complex in the beating heart of a live zebrafish embryo. Detected single GFP emission reports time-resolved myosin lever-arm orientation interpreted as step-size and step-frequency providing single myosin mechanical characteristics over the active cycle. Following step-frequency of cardiac ventriculum myosin transitioning from low to high force in relaxed to auxotonic to isometric contraction phases indicates that the imposition of resisting force during contraction causes the motor to down-shift to the 3 nm step-size accounting for >80% of all the steps in the near-isometric phase. At peak force, the ATP initiated actomyosin dissociation is the predominant strain inhibited transition in the native myosin contraction cycle. The proposed model for motor down-shifting and strain sensing involves ELC N

  4. Safety and Efficacy of Acute Clopidogrel Load in Patients with Moderate and Severe Ischemic Strokes

    Directory of Open Access Journals (Sweden)

    Amir Shaban

    2016-01-01

    Full Text Available Objective. To study the safety and efficacy of a clopidogrel loading dose in patients with moderate and severe acute ischemic strokes. Background. The safety of clopidogrel loading has been extensively investigated in patients with minor strokes and transient ischemic attacks. Methods. Acute ischemic stroke patients presenting consecutively to our center from 07/01/08 to 07/31/13 were screened. Clopidogrel loading was defined as at least 300 mg dose (with or without aspirin given within 6 hours of admission. We compared outcomes in patients with baseline NIHSS > 3 with and without clopidogrel loading. Results. Inclusion criteria were met for 1011 patients (43.6% females, 69.1% black, median age 63. Patients with clopidogrel loading had lower baseline NIHSS than patients who were not loaded (8 versus 9, p=0.005. The two groups had similar risk for hemorrhagic transformation (p=0.918 and symptomatic hemorrhage (p=0.599. Patients who were loaded had a lower rate of neurological worsening (38.9% versus 48.3%, p=0.031 and less in-hospital mortality (4.3% versus 13.4%, p=0.001 compared to those who were not loaded. The likelihood of having a poor functional outcome did not differ between the two groups after adjusting for NIHSS on admission (OR = 0.71, 95% CI 0.4633–1.0906, p=0.118. Conclusion. Clopidogrel loading dose was not associated with increased risk for hemorrhagic transformation or symptomatic intracranial hemorrhage in our retrospective study and was associated with reduced rates of neuroworsening following moderate and severe stroke.

  5. Properties of polymer-filled aluminium foams under moderate strain-rate loading conditions

    Czech Academy of Sciences Publication Activity Database

    Doktor, Tomáš; Zlámal, Petr; Fíla, Tomáš; Koudelka_ml., Petr; Kytýř, Daniel; Jiroušek, O.

    2015-01-01

    Roč. 49, č. 4 (2015), s. 597-600 ISSN 1580-2949 R&D Projects: GA ČR(CZ) GAP105/12/0824 Institutional support: RVO:68378297 Keywords : interpenetrating-phase composite * compression * aluminium foam * polyurethane * moderate strain-rate loading Subject RIV: JJ - Other Materials Impact factor: 0.439, year: 2015 http://mit.imt.si/Revija/izvodi/mit154/doktor.pdf

  6. Simplified static method for determining seismic loads on equipment in moderate and high hazard facilities

    International Nuclear Information System (INIS)

    Scott, M.A.; Holmes, P.A.

    1991-01-01

    A simplified static analysis methodology is presented for qualifying equipment in moderate and high-hazard facility-use category structures, where the facility use is defined in Design and Evaluation Guidelines for Department of Energy Facilities Subjected to Natural Phenomena Hazards, UCRL-15910. Currently there are no equivalent simplified static methods for determining seismic loads on equipment in these facility use categories without completing dynamic analysis of the facility to obtain local floor accelerations or spectra. The requirements of UCRL-15910 specify the use of open-quotes dynamicclose quotes analysis methods, consistent with Seismic Design Guidelines for Essential Buildings, Chapter 6, open-quotes Nonstructural Elements,close quotes TM5-809-10-1, be used for determining seismic loads on mechanical equipment and components. Chapter 6 assumes that the dynamic analysis of the facility has generated either floor response spectra or model floor accelerations. These in turn are utilized with the dynamic modification factor and the actual demand and capacity ratios to determine equipment loading. This complex methodology may be necessary to determine more exacting loads for hard to qualify equipment but does not provide a simple conservative loading methodology for equipment with ample structural capacity

  7. Effects of Moderate Exercise on Relieving Mental Load of Elementary School Teachers

    Directory of Open Access Journals (Sweden)

    Shing-Hong Liu

    2015-01-01

    Full Text Available Long-term endurance exercise could increase activity of parasympathetic nervous and decrease activity of sympathetic nervous at rest. However, previous studies all focused on the effect of endurance training on heart rate variability (HRV for athletes or sedentary subjects. In Taiwan, elementary school teachers teaching and processing the children’s and administrative problems always stand and walk. They will sit down only when they review and correct the students’ home work. Thus, the goal of this study was to elucidate the beneficial effect of moderate intensity exercise on relieving mental load of elementary school teachers. There were 20 participants in the exercise group and another 20 participants in the nonexercise group. The exercising teachers performed 12 weeks of moderate intensity exercise training for an average of 30 minutes per day, 3 times per week. HRV was measured before and after the 4th, 6th, and 12th weeks. The time and frequency domain parameters of HRV all had significant increases between the beginning and after 12 weeks of training. However, the time and frequency domain parameters of HRV in the nonexercise group had significant decreases between the beginning and after 12 weeks of training. The long-term moderate exercises can relieve mental load of elementary school teachers. Moreover, age was the considerable factor affecting HRV in this study.

  8. Elasto/visco-plastic analysis of orthotropic moderately thick shells of revolution under asymmetrical loading

    International Nuclear Information System (INIS)

    Tao, K.; Takezono, S.

    1989-01-01

    An analytical method for the elasto/visco-plastic problems of general, orthotropic moderately thick shells of revolution subjected to asymmetrical loads is developed in consideration of the effect of shear deformations. The Reissner-Naghdi theory for elastic moderately thick shells is extended in this analysis. As the constitutive equation, Hooke's law for orthotropic materials is used in the elastic region, and equations based on the orthotropic visco-plastic theory derived from the orthotropic plastic theory by Hill are employed in the plastic range. The visco-plastic strain rates are related to the stresses by Perzyna's equation. The fundamental equations for the increment are numerically solved by a finite difference method and the solutions are obtained by summation of the incremental values. In order to check the adequacy of the numerical analysis, experiments are performed on the elasto/visco-plastic deformation of a titanium cylindrical shell subjected to locally distributed loads. Good agreement is obtained between the experimental results and analytical solutions

  9. Elasto/visco-plastic analysis of moderately thick shells of revolution under asymmetrical loading

    International Nuclear Information System (INIS)

    Tao, K.; Takezono, S.

    1987-01-01

    In the present paper the analytical formulation for the elasto/visco-plastic problems of general, moderately thick shells of revolution subjected to asymmetrical loads is developed in consideration of the effect of shear deformation. The equations of equilibrium and the relations between the strains and displacements are derived by extending the Reissner-Naghdi theory (1941, 1957) for elastic shells with given consideration to the effect of shear deformation. As the constitutive relation, Hooke's law is used in the liner elastic range, and the elasto/visco-plastic equations by Perzyna (1966) are employed in the plastic range. The fundamental equations on the elasto/visco-plastic problems derived for incremental values are numerically solved by a finite difference method and the solutions are obtained by summation of the incremental values. (orig./GL)

  10. Children's Emotionality Moderates the Association Between Maternal Responsiveness and Allostatic Load: Investigation Into Differential Susceptibility.

    Science.gov (United States)

    Dich, Nadya; Doan, Stacey N; Evans, Gary W

    2015-01-01

    While emotionality is often thought of as a risk factor, differential susceptibility theory argues that emotionality reflects susceptibility to both positive and negative environmental influences. The present study explored whether emotional children might be more susceptible to the effects of both high and low maternal responsiveness on allostatic load, a physiological indicator of chronic stress. Participants were 226 mother and child dyads. Mothers reported on children's emotionality at child age 9. Maternal responsiveness was measured at age 13 using self-reports and behavioral observation. Allostatic load was measured at age 13 and 17 using neuroendocrine, cardiovascular, and metabolic biomarkers. Emotionality was associated with higher allostatic load if self-reported responsiveness was low, but with lower allostatic load, when self-reported responsiveness was high. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  11. Life events trajectories, allostatic load, and the moderating role of age at arrival from Puerto Rico to the US mainland.

    Science.gov (United States)

    Arévalo, Sandra P; Tucker, Katherine L; Falcón, Luis M

    2014-11-01

    Our aim was to examine the effects of trajectories of stressful life events on allostatic load, measured over a two year time period, and to investigate the roles of language acculturation and age at migration in this association, in a sample of Puerto Rican migrants. We used data from the Boston Puerto Rican Health Study; a population-based prospective cohort of older Puerto Ricans recruited between the ages of 45 and 75 years. The Institutional Review Boards at Tufts Medical Center and Northeastern University approved the study. We used latent growth mixture modeling (LGMM) to identify different classes of two-year trajectories of stressful life events; analysis of variance to examine group differences by stress trajectory; and linear regression to test for the modifying effects of age at arrival on the association of stress trajectory with allostatic load at follow-up. In LGMM analysis, we identified three distinct stress trajectories; low, moderate ascending, and high. Unexpectedly, participants in the low stress group had the highest allostatic load at follow-up (F=4.4, p=0.01) relative to the other two groups. Age at arrival had a statistically significant moderating effect on the association. A reported two year period of moderate but repetitive and increasingly bad life events was associated with increases in allostatic load for participants who arrived to the U.S. mainland after the age of 5 years, and was particularly strong for those arriving between 6 and 11 years, but not for those arriving earlier or later. Results from this study highlight the complex effects of stress during the life course, and point to certain vulnerable periods for immigrant children that could modify long term effects of stress. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Children's Emotionality Moderates the Association Between Maternal Responsiveness and Allostatic Load

    DEFF Research Database (Denmark)

    Dich, Nadya; Doan, Stacey N; Evans, Gary W

    2015-01-01

    high and low maternal responsiveness on allostatic load, a physiological indicator of chronic stress. Participants were 226 mother and child dyads. Mothers reported on children's emotionality at child age 9. Maternal responsiveness was measured at age 13 using self-reports and behavioral observation...

  13. A moderate enthalpy and a low pollution load in healthy buildings

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1998-01-01

    complaints caused by individual differences. The building should be acknowledged as a source of pollution and this source should be minimized during design by the selection of proper building materials and HVAC components. To improve ventilation effctiveness, supply of air close to the breathing zone of each......For the design of healthy buildings with a comfortable indoor environment, some general recommendations are provided. New research highlights the importance of controlling the enthalpy of indoor air at a moderate level, i.e., by controlling air temperature and relative humidity at a rather low...... level, still compatible with thermal comfort. A decrement of air temperature or humidity improves the perceived air quality and may decrease the required ventilation rate. A moderate air temperature and humidity plus individual control by radiation and conduction is recommended in order to decrease...

  14. Higher education moderates the effect of T2 lesion load and third ventricle width on cognition in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Daniela Pinter

    Full Text Available BACKGROUND: Previous work suggested greater intellectual enrichment might moderate the negative impact of brain atrophy on cognition. This awaits confirmation in independent cohorts including investigation of the role of T2-lesion load (T2-LL, which is another important determinant of cognition in MS. We here thus aimed to test this cognitive reserve hypothesis by investigating whether educational attainment (EA moderates the negative effects of both brain atrophy and T2-LL on cognitive function in a large sample of MS patients. METHODS: 137 patients participated in the study. Cognition was assessed by the "Brief Repeatable Battery of Neuropsychological Tests." T2-LL, normalized brain volume (global volume loss and third ventricle width (regional volume loss served as MRI markers. RESULTS: Both T2-LL and atrophy predicted worse cognition, with a stronger effect of T2-LL. Higher EA (as assessed by years of education also predicted better cognition. Interactions showed that the negative effects of T2-LL and regional brain atrophy were moderated by EA. CONCLUSIONS: In a cohort with different stages of MS, higher EA attenuated the negative effects of white matter lesion burden and third ventricle width (suggestive of thalamic atrophy on cognitive performance. Actively enhancing cognitive reserve might thus be a means to reduce or prevent cognitive problems in MS in parallel to disease modifying drugs.

  15. The creep of multi-layered moderately thick shells of revolution under asymmetrical loading

    International Nuclear Information System (INIS)

    Takezono, S.; Migita, K.

    1987-01-01

    In the present paper the authors study the creep deformation of the multi-layered thick shells of revolution under asymmetrical loads. The equations of equilibrium and the strain-displacement relations are derived from the Reissner-Naghdi theory (1941, 1957) for elastic shells where a consideration on the effect of shear deformation is given. In the theory of creep it is assumed that in a given increment of time the total strain increments are composed of an elastic part and a part due to creep. The elastic strains are proportional to the stresses by Hooke's law. For the constitutive equations in the creep range, McVetty's equation modified by Arrhenius' equation for thermal effect is employed. The basic differential equations on the creep problems derived for the incremental values with respect to time are numerically solved by a finite difference method and the solutions at any time are obtained by summation of the incremental values. Resultant forces and resultant moments are given from numerical integration of the stresses by Simpson's 1/3 rules. (orig./GL)

  16. Emotion-attention interactions in fear conditioning: Moderation by executive load, neuroticism, and awareness.

    Science.gov (United States)

    Hur, Juyoen; Iordan, Alexandru D; Berenbaum, Howard; Dolcos, Florin

    2016-12-01

    Despite increasing evidence suggesting interactive effects of emotion and attention on perceptual processing, it still remains unclear how their interplay influences affective learning, such as fear conditioning. In the present study, a conditioning procedure using threat-related conditioned stimuli (CSs) was implemented while executive load and attentional focus were manipulated. The modulation effects of neuroticism and contingency awareness were also examined. Results showed that fear conditioning depended on the available executive resources even with threat-related CSs. In addition, although individuals with high neuroticism showed an enhanced conditioning effect overall, this facilitation effect still depended on the availability of executive resources. Finally, the impact of attentional focus was most evident among individuals with high neuroticism who were aware of the contingency. Overall, the present study demonstrates interactive effects of emotion and attention in fear conditioning, while illuminating mechanisms of individual differences and clarifying the controversial role of contingency awareness in fear conditioning. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Detailed description of an SSAC at the facility level for light water moderated (off-load refueled) power reactor facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-03-01

    This report is intended to provide the technical details of an effective State Systems of Accounting for and Control of Nuclear Material (SSAC) which Member States may use, if they wish, to establish and maintain their SSACs. It is expected that systems designed along the lines described would be effective in meeting the objectives of both national and international systems for nuclear material accounting and control. This document accordingly provides a detailed description of a system for the accounting for and control of nuclear material in an off-load refueled light water moderated power reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  18. Cranio-cervical flexor muscle impairment at maximal, moderate, and low loads is a feature of neck pain.

    Science.gov (United States)

    O'Leary, Shaun; Jull, Gwendolen; Kim, Mehwa; Vicenzino, Bill

    2007-02-01

    Impairment of the cranio-cervical flexor (CCF) muscles is a feature of painful cervical spine disorders. The aim of this study was to investigate if CCF muscle impairment is present over a range of contraction intensities (maximal, moderate, low) in neck pain sufferers compared to individuals with no history of neck pain. Isometric CCF muscle strength (isometric maximal voluntary contraction (MVC)), and endurance at moderate (50% of MVC), and low (20% of MVC) loads was compared in 46 participants with neck pain (Neck Disability Index (NDI): mean+/-SD; 22.8+/-5.2) and 47 control participants (NDI: 2.6+/-2.6). Compared to the control group, the neck pain group had a significant deficit (15.9%, P=0.037) in their MVC peak torque recordings, as well as a significantly reduced capacity to sustain isometric CCF muscle contractions to task failure at 20% of MVC (35% deficit, P=0.03) and 50% of MVC (27% deficit, P=0.002). Neck pain participants also demonstrated poorer accuracy in maintaining their MVC(20) contraction at the nominated isometric CCF torque amplitude (P=0.02), compared to control participants. It would appear that impairment in isometric CCF muscle performance exists over a range of contraction intensities in neck pain sufferers, which may benefit from specific therapeutic intervention.

  19. Elasto/visco-plastic deformation of moderately thick shells of revolution under thermal loading due to fluid

    International Nuclear Information System (INIS)

    Takezono, S.; Tao, K.; Aoki, T.; Inamura, E.

    1993-01-01

    This paper is concerned with an analytical formulation and a numerical solution of the thermo-elasto/visco-plastic deformation of general, moderately thick shells of revolution subjected to thermal loads due to fluid. At first the temperature distribution through the thickness is supposed to be curves of second order, and the temperature field in the shell under the appropriate initial and boundary conditions is determined by using the equations of heat conduction and heat transfer. Secondly the stresses and deformations are derived from the thermal stress equations. The equations of equilibrium and the relations between the strains and displacements are developed by extending the Reissner-Naghdi theory for elastic shells. For the constitutive relations, the Perzyna elasto/visco-plastic equations including the temperature effect are employed. The fundamental equations derived are numerically solved by the finite difference method. As a numerical example, the simply supported cylindrical shell made of mild steel under thermal loading due to fluid is analyzed, and the results are compared with those from classical theory which neglects the effect of shear deformations. (author)

  20. Students' Scientific Epistemic Beliefs, Online Evaluative Standards, and Online Searching Strategies for Science Information: The Moderating Role of Cognitive Load Experience

    Science.gov (United States)

    Hsieh, Ya-Hui; Tsai, Chin-Chung

    2014-01-01

    The purpose of this study is to examine the moderating role of cognitive load experience between students' scientific epistemic beliefs and information commitments, which refer to online evaluative standards and online searching strategies. A total of 344 science-related major students participated in this study. Three questionnaires were…

  1. Epitope specificity is critical for high and moderate avidity cytotoxic T lymphocytes associated with control of viral load and clinical disease in horses with equine infectious anemia virus.

    Science.gov (United States)

    Mealey, Robert H; Zhang, Baoshan; Leib, Steven R; Littke, Matt H; McGuire, Travis C

    2003-09-01

    Equine infectious anemia virus (EIAV) is a lentivirus that causes persistent infections in horses. We hypothesized that high-avidity CTL specific for nonvariable epitopes might be associated with low viral load and minimal disease in EIAV-infected horses. To test this hypothesis, memory CTL (CTLm) responses were analyzed in two infected horses with high plasma viral loads and recurrent disease (progressors), and in two infected horses with low-to-undetectable viral loads and mild disease (nonprogressors). High-avidity CTLm in one progressor recognized an envelope gp90 epitope, and the data documented for the first time in EIAV that viral variation led to CTL escape. Each of the nonprogressors had high-to-moderate avidity CTLm directed against epitopes within Rev, including the nuclear export and nuclear localization domains. These results suggested that the epitope specificity of high- and moderate-avidity CTLm was an important determinant for disease outcome in the EIAV-infected horses examined.

  2. Epitope specificity is critical for high and moderate avidity cytotoxic T lymphocytes associated with control of viral load and clinical disease in horses with equine infectious anemia virus

    International Nuclear Information System (INIS)

    Mealey, Robert H.; Zhang Baoshan; Leib, Steven R.; Littke, Matt H.; McGuire, Travis C.

    2003-01-01

    Equine infectious anemia virus (EIAV) is a lentivirus that causes persistent infections in horses. We hypothesized that high-avidity CTL specific for nonvariable epitopes might be associated with low viral load and minimal disease in EIAV-infected horses. To test this hypothesis, memory CTL (CTLm) responses were analyzed in two infected horses with high plasma viral loads and recurrent disease (progressors), and in two infected horses with low-to-undetectable viral loads and mild disease (nonprogressors). High-avidity CTLm in one progressor recognized an envelope gp90 epitope, and the data documented for the first time in EIAV that viral variation led to CTL escape. Each of the nonprogressors had high-to-moderate avidity CTLm directed against epitopes within Rev, including the nuclear export and nuclear localization domains. These results suggested that the epitope specificity of high- and moderate-avidity CTLm was an important determinant for disease outcome in the EIAV-infected horses examined

  3. Epitope specificity is critical for high and moderate avidity cytotoxic T lymphocytes associated with control of viral load and clinical disease in horses with equine infectious anemia virus

    Science.gov (United States)

    Mealey, Robert H.; Zhang, Baoshan; Leib, Steven R.; Littke, Matt H.; McGuire, Travis C.

    2012-01-01

    Equine infectious anemia virus (EIAV) is a lentivirus that causes persistent infections in horses. We hypothesized that high-avidity CTL specific for nonvariable epitopes might be associated with low viral load and minimal disease in EIAV-infected horses. To test this hypothesis, memory CTL (CTLm) responses were analyzed in two infected horses with high plasma viral loads and recurrent disease (progressors), and in two infected horses with low-to-undetectable viral loads and mild disease (nonprogressors). High-avidity CTLm in one progressor recognized an envelope gp90 epitope, and the data documented for the first time in EIAV that viral variation led to CTL escape. Each of the nonprogressors had high-to-moderate avidity CTLm directed against epitopes within Rev, including the nuclear export and nuclear localization domains. These results suggested that the epitope specificity of high- and moderate-avidity CTLm was an important determinant for disease outcome in the EIAV-infected horses examined. PMID:12954220

  4. Composition of The Knee Index, a novel three-dimensional biomechanical index for knee joint load, in subjects with mild to moderate knee osteoarthritis

    DEFF Research Database (Denmark)

    Clausen, Brian; Andriacchi, Tom; Nielsen, Dennis Brandborg

    Background Knee joint load is an important factor associated with progression of knee osteoarthritis. To provide an overall understanding of knee joint loading, the Knee Index (KI) has been developed to include moments from all three planes (frontal, sagittal and transversal). However, before KI...... is used in clinical trials a biomechanical analysis identifying the respective contributions of the knee moments derived from the three planes is needed. Aim The purpose of this study was therefor to investigate how the frontal, sagittal and transversal moments contribute to KI, a novel biomechanical...... index of joint load for the knee, in patients with mild to moderate knee osteoarthritis. Methods The contribution of frontal, sagittal and transversal plane knee moments to KI was investigated in 24 subjects (13 women, age: 58 ± 7.6 years, BMI: 27.1 ± 3.0) with clinically diagnosed mild to moderate knee...

  5. Apolipoprotein E genotype does not moderate the associations of depressive symptoms, neuroticism and allostatic load with cognitive ability and cognitive aging in the Lothian Birth Cohort 1936.

    Directory of Open Access Journals (Sweden)

    Zander Crook

    Full Text Available In this replication-and-extension study, we tested whether depressive symptoms, neuroticism, and allostatic load (multisystem physiological dysregulation were related to lower baseline cognitive ability and greater subsequent cognitive decline in older adults, and whether these relationships were moderated by the E4 allele of the apolipoprotein E (APOE gene. We also tested whether allostatic load mediated the relationships between neuroticism and cognitive outcomes.We used data from the Lothian Birth Cohort 1936 (n at Waves 1-3: 1,028 [M age = 69.5 y]; 820 [M duration since Wave 1 = 2.98 y]; 659 [M duration since Wave 1 = 6.74 y]. We fitted latent growth curve models of general cognitive ability (modeled using five cognitive tests with groups of APOE E4 non-carriers and carriers. In separate models, depressive symptoms, neuroticism, and allostatic load predicted baseline cognitive ability and subsequent cognitive decline. In addition, models tested whether allostatic load mediated relationships between neuroticism and cognitive outcomes.Baseline cognitive ability had small-to-moderate negative associations with depressive symptoms (β range = -0.20 to -0.17, neuroticism (β range = -0.27 to -0.23, and allostatic load (β range = -0.11 to 0.09. Greater cognitive decline was linked to baseline allostatic load (β range = -0.98 to -0.83 and depressive symptoms (β range = -1.00 to -0.88. However, APOE E4 allele possession did not moderate the relationships of depressive symptoms, neuroticism and allostatic load with cognitive ability and cognitive decline. Additionally, the associations of neuroticism with cognitive ability and cognitive decline were not mediated through allostatic load.Our results suggest that APOE E4 status does not moderate the relationships of depressive symptoms, neuroticism, and allostatic load with cognitive ability and cognitive decline in healthy older adults. The most notable positive finding in the current research was

  6. Effects of resistance training with moderate vs heavy loads on muscle mass and strength in the elderly: A meta-analysis.

    Science.gov (United States)

    Csapo, R; Alegre, L M

    2016-09-01

    The purpose of the present study was to perform a meta-analysis to compare the efficacy of heavy (∼80% of one repetition maximum, 1RM) vs light-moderate load (∼45% 1RM) resistance training (RT) programs in inducing strength gains and skeletal muscle hypertrophy in elderly people. To assess the role of training volumes, studies in which training protocols were matched for mechanical work were independently analyzed. In all 15 studies included (448 subjects, age 67.8 years), when comparing heavy with light-moderate loads, strength gains tended to be larger following RT with higher intensities of load, with the resulting total population effect being μ = 0.430 (P = 0.060). Effect sizes were substantially smaller in "work-matched" studies (μ = 0.297, P = 0.003). Training with higher loads also provoked marginally larger gains in muscle size, although the degree of training-induced muscle hypertrophy was generally small (0.056 lower than traditionally recommended intensities of load may suffice to induce substantial gains in muscle strength in elderly cohorts. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Effects of Early Moderate Loading on Implant Stability: A Retrospective Investigation of 634 Implants with Platform Switching and Morse-Tapered Connections.

    Science.gov (United States)

    Romanos, Georgios; Grizas, Eleftherios; Laukart, Elena; Nentwig, Georg-Hubertus

    2016-04-01

    This retrospective investigation aimed to evaluate the effect of early moderate loading (EML) on implant stability. Following 6 weeks of conventional healing, 634 dental implants (Ankylos®, Dentsply Implants, Mannheim, Germany) inserted in 247 patients were uncovered. Provisional restorations were placed in infra-occlusion in partially edentulous patients and in full occlusion in edentulous patients. Patients were instructed to consume a soft/liquid diet until final restorations were delivered after approximately 6 weeks. Periotest values (PTVs) at the time of uncovering and after EML were assessed in order to calculate the change in PTV (ΔPTV). Improvement of the PTV was analyzed to account for dependencies between measurements on multiple implants of a single patient, along with other factors. No implant was lost during the EML. After a mean loading time of 3 years (± 1.7 years), the implant survival rate was 98.74%. The PTV of 556 implants decreased (improved) over the course of the study. The ΔPTV was statistically significant (p = .0001), and none of the factors analyzed appeared to influence it. The EML of implants does not impair the implants' stability, as determined by Periotest. On the contrary, early moderate loading seems to be beneficial at compromised bone qualities. © 2015 Wiley Periodicals, Inc.

  8. Does collective efficacy moderate the associations between physical work load and intention to leave or sickness absence?

    Science.gov (United States)

    Jensen, Jette Nygaard; Holten, Ann-Louise; Karpatschof, Benny; Albertsen, Karen

    2011-11-01

    This paper is a report of a study, which examines the moderating effect of collective efficacy on the associations between physical workload, intention to leave and sickness absence. The positive association between physical workload and both intention to leave and sickness absence in the healthcare sector is well-established. However, knowledge is limited with respect to how social contextual factors such as collective efficacy moderate these associations. A questionnaire was distributed over a 4-month period in 2006/2007 to all employees at elderly care centres in 35 Danish municipalities who were asked to rate their groups' collective efficacy. The final sample consisted of 6929 female employees from 290 work groups. Employees were predominantly healthcare helpers and assistants, but also nurses and other healthcare professionals participated in the study. Information on collective efficacy was aggregated to work group level. Collective efficacy moderated the association between physical workload and intention to leave, i.e. employees with high levels of physical workload had lower intention to leave if they worked in a group with high levels of collective efficacy and higher intention to leave if they worked in a group with low levels of collective efficacy. No moderating effect of collective efficacy on the association between physical workload and sickness absence was found. Our findings suggest that enhancing the sense of collective efficacy might be a mean for organizations and managers to reduce intention to leave, but further research is needed. © 2011 Blackwell Publishing Ltd.

  9. Characterising the fracture toughness of polymers at moderately high rates of loading with the use of instrumented tensile impact testing

    NARCIS (Netherlands)

    Visser, Roy; Caimmi, F.; Pavan, A.

    2013-01-01

    The more common use of instrumentation in impact testing opened up the possibility to apply fracture mechanics testing methods to polymers at moderately high impact rates. Tensile impact testing offers some advantages over the more common three-point bending and compact tension geometries. Most

  10. Working memory capacity as a moderator of load-related frontal midline theta variability in Sternberg task

    Directory of Open Access Journals (Sweden)

    Marta Zuzanna Zakrzewska

    2014-06-01

    Full Text Available The aim of this study was to investigate the relationship between working memory capacity (WMC and frontal theta response to memory load in Sternberg task. We show that oscillatory activity in the theta band (4 – 6 Hz related to Sternberg task performance may differentiate people characterized by high and low WMC. Specifically, there is a linear increase of frontal midline (FM theta power with load, however only in the high working memory capacity group. Furthermore, a positive linear relationship was found between WMC (OSPAN score and average FM theta power increase from lower to higher loads which was not present at other scalp locations. The distinct patterns of high and low WMC individual’s FM theta response to memory load seem to support the assumption that theta activity during maintenance reflects not only the amount of information stored, but also the effort it takes to remember them and the efficiency of involved neural processes. This contributes to perceiving FM theta as an individual trait which can reflect individual working memory mechanism efficiency.

  11. Mechanical Behavior of AZ31B Mg Alloy Sheets under Monotonic and Cyclic Loadings at Room and Moderately Elevated Temperatures

    Science.gov (United States)

    Nguyen, Ngoc-Trung; Seo, Oh Suk; Lee, Chung An; Lee, Myoung-Gyu; Kim, Ji-hoon; Kim, Heon Young

    2014-01-01

    Large-strain monotonic and cyclic loading tests of AZ31B magnesium alloy sheets were performed with a newly developed testing system, at different temperatures, ranging from room temperature to 250 °C. Behaviors showing significant twinning during initial in-plane compression and untwinning in subsequent tension at and slightly above room temperature were recorded. Strong yielding asymmetry and nonlinear hardening behavior were also revealed. Considerable Bauschinger effects, transient behavior, and variable permanent softening responses were observed near room temperature, but these were reduced and almost disappeared as the temperature increased. Different stress–strain responses were inherent to the activation of twinning at lower temperatures and non-basal slip systems at elevated temperatures. A critical temperature was identified to account for the transition between the twinning-dominant and slip-dominant deformation mechanisms. Accordingly, below the transition point, stress–strain curves of cyclic loading tests exhibited concave-up shapes for compression or compression following tension, and an unusual S-shape for tension following compression. This unusual shape disappeared when the temperature was above the transition point. Shrinkage of the elastic range and variation in Young’s modulus due to plastic strain deformation during stress reversals were also observed. The texture-induced anisotropy of both the elastic and plastic behaviors was characterized experimentally. PMID:28788514

  12. Mechanical Behavior of AZ31B Mg Alloy Sheets under Monotonic and Cyclic Loadings at Room and Moderately Elevated Temperatures

    Directory of Open Access Journals (Sweden)

    Ngoc-Trung Nguyen

    2014-02-01

    Full Text Available Large-strain monotonic and cyclic loading tests of AZ31B magnesium alloy sheets were performed with a newly developed testing system, at different temperatures, ranging from room temperature to 250 °C. Behaviors showing significant twinning during initial in-plane compression and untwinning in subsequent tension at and slightly above room temperature were recorded. Strong yielding asymmetry and nonlinear hardening behavior were also revealed. Considerable Bauschinger effects, transient behavior, and variable permanent softening responses were observed near room temperature, but these were reduced and almost disappeared as the temperature increased. Different stress–strain responses were inherent to the activation of twinning at lower temperatures and non-basal slip systems at elevated temperatures. A critical temperature was identified to account for the transition between the twinning-dominant and slip-dominant deformation mechanisms. Accordingly, below the transition point, stress–strain curves of cyclic loading tests exhibited concave-up shapes for compression or compression following tension, and an unusual S-shape for tension following compression. This unusual shape disappeared when the temperature was above the transition point. Shrinkage of the elastic range and variation in Young’s modulus due to plastic strain deformation during stress reversals were also observed. The texture-induced anisotropy of both the elastic and plastic behaviors was characterized experimentally.

  13. The Immediate Effects of Conventional Physical Therapy on the Knee Joint Load in Subjects with Moderate Knee Osteoarthritis; A Preliminary Single Blinded Randomized Control Trial

    Directory of Open Access Journals (Sweden)

    Leila Fattahi

    2015-12-01

    Full Text Available Background: Subjects with knee osteoarthritis typically have higher knee adduction moment. Current research efforts are mainly focused on therapeutic procedures that potentially may modify disease progression. This preliminary study was designed as a single blind (examiner randomized control trial to investigate the impact of conventional physical therapy on pain, and knee joint load in subjects with moderate knee osteoarthritis. Methods: Twelve participants diagnosed with moderate knee OA were randomly assigned into control and intervention groups. Three-dimensional knee kinematic and kinetic data were recorded during the gait before and after 10 sessions of conventional physical therapy. In addition, pain intensity was evaluated by visual analog scale and pain subscale of KOOS questionnaire. The control group did not receive any intervention during the same period. Gait parameters were analyzed within and between groups using nonparametric tests. Results: There was a significant difference between groups in baseline KOOS-pain Score and ML knee force (P=0.048 and P=0.01. Immediately after ten sessions of physical therapy the initial (first peak of knee adduction moment was significantly (P=0.03 lower than that of the control group while the first and second peak of knee AP velocity were significantly (P=0.02, P=0.01 respectively higher. In the intervention group, the second peaks of vertical and anteroposterior (AP knee forces were strongly correlated with the pretest KOOS-pain Score (r=0.99 and r=0.98, P<0.001. Therefore a multivariate general linear model was adopted with adjustment to baseline KOOS-pain. By this adjustment, 51% alleviation of VAS pain score and 81% decrement of first peak of knee adduction moment in comparison to control group was statistically significant (P=0.02, P=0.03 respectively. Conclusion: It seems that ten sessions of conventional physical therapy may modify knee joint load in subjects with moderate knee

  14. Moderate loading of the human osteoarthritic knee joint leads to lowering of intraarticular cartilage oligomeric matrix protein

    DEFF Research Database (Denmark)

    Helmark, Ida C; Petersen, Marie C H; Christensen, Helle E

    2012-01-01

    osteoarthritic joint determined by biochemical markers of cartilage turnover and inflammation in the synovial fluid (SF), serum and urine. Eleven subjects with OA of the knee(s), but with no other joint- or inflammatory disorders, volunteered for the study and had samples of blood, urine and synovial fluid drawn...... knee joint in human subjects with knee OA resulted in a reduced COMP concentration in SF.......The non-pharmacological treatment of osteoarthritis (OA) includes exercise therapy; however, little is known about the specific effect of exercise on the joint per se. The purpose of the present study was to investigate the direct effects of a load-bearing exercise upon cartilage in a single, human...

  15. Loading of the knee during 3.0 T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Stehling, Christoph, E-mail: christoph.stehling@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA (United States); Department of Clinical Radiology, University of Muenster, Muenster (Germany); Souza, Richard B. [Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA (United States); Graverand, Marie-Pierre Hellio Le; Wyman, Bradley T. [Pfizer Inc. New London, CT (United States); Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M. [Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA (United States)

    2012-08-15

    Purpose: Standard knee MRI is performed under unloading (ULC) conditions and not much is known about changes of the meniscus, ligaments or cartilage under loading conditions (LC). The aim is to study the influence of loading of different knee structures at 3 Tesla (T) in subjects with osteoarthritis (OA) and normal controls. Materials and methods: 30 subjects, 10 healthy and 20 with radiographic evidence of OA (10 mild and 10 moderate) underwent 3 T MRI under ULC and LC at 50% body weight. All images were analyzed by two musculoskeletal radiologists identifying and grading cartilage, meniscal, ligamentous abnormalities. The changes between ULC and LC were assessed. For meniscus, cartilage and ligaments the changes of lesions, signal and shape were evaluated. In addition, for the meniscus changes in extrusion were examined. A multivariate regression model was used for correlations to correct the data for the impact of age, gender, BMI. A paired T-Test was performed to calculate the differences in meniscus extrusion. Results: Subjects with degenerative knee abnormalities demonstrated significantly increased meniscus extrusion under LC when compared to normal subjects (p = 0.0008-0.0027). Subjects with knee abnormalities and higher KL scores showed significantly more changes in lesion, signal and shape of the meniscus (80% (16/20) vs. 20% (2/10); p = 0.0025), ligaments and cartilage during LC. Conclusion: The study demonstrates that axial loading has an effect on articular cartilage, ligament, and meniscus morphology, which is more significant in subjects with degenerative disease and may serve as an additional diagnostic tool for disease diagnosis and assessing progression in subjects with knee OA.

  16. Loading of the knee during 3.0 T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis

    International Nuclear Information System (INIS)

    Stehling, Christoph; Souza, Richard B.; Graverand, Marie-Pierre Hellio Le; Wyman, Bradley T.; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M.

    2012-01-01

    Purpose: Standard knee MRI is performed under unloading (ULC) conditions and not much is known about changes of the meniscus, ligaments or cartilage under loading conditions (LC). The aim is to study the influence of loading of different knee structures at 3 Tesla (T) in subjects with osteoarthritis (OA) and normal controls. Materials and methods: 30 subjects, 10 healthy and 20 with radiographic evidence of OA (10 mild and 10 moderate) underwent 3 T MRI under ULC and LC at 50% body weight. All images were analyzed by two musculoskeletal radiologists identifying and grading cartilage, meniscal, ligamentous abnormalities. The changes between ULC and LC were assessed. For meniscus, cartilage and ligaments the changes of lesions, signal and shape were evaluated. In addition, for the meniscus changes in extrusion were examined. A multivariate regression model was used for correlations to correct the data for the impact of age, gender, BMI. A paired T-Test was performed to calculate the differences in meniscus extrusion. Results: Subjects with degenerative knee abnormalities demonstrated significantly increased meniscus extrusion under LC when compared to normal subjects (p = 0.0008–0.0027). Subjects with knee abnormalities and higher KL scores showed significantly more changes in lesion, signal and shape of the meniscus (80% (16/20) vs. 20% (2/10); p = 0.0025), ligaments and cartilage during LC. Conclusion: The study demonstrates that axial loading has an effect on articular cartilage, ligament, and meniscus morphology, which is more significant in subjects with degenerative disease and may serve as an additional diagnostic tool for disease diagnosis and assessing progression in subjects with knee OA.

  17. Effects of Moderate-Volume, High-Load Lower-Body Resistance Training on Strength and Function in Persons with Parkinson's Disease: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Brian K. Schilling

    2010-01-01

    Full Text Available Background. Resistance training research has demonstrated positive effects for persons with Parkinson's disease (PD, but the number of acute training variables that can be manipulated makes it difficult to determine the optimal resistance training program. Objective. The purpose of this investigation was to examine the effects of an 8-week resistance training intervention on strength and function in persons with PD. Methods. Eighteen men and women were randomized to training or standard care for the 8-week intervention. The training group performed 3 sets of 5–8 repetitions of the leg press, leg curl, and calf press twice weekly. Tests included leg press strength relative to body mass, timed up-and-go, six-minute walk, and Activities-specific Balance Confidence questionnaire. Results. There was a significant group-by-time effect for maximum leg press strength relative to body mass, with the training group significantly increasing their maximum relative strength (P.05. Conclusions. Moderate volume, high-load weight training is effective for increasing lower-body strength in persons with PD.

  18. In situ x-ray diffraction study of crystal structure of Pd during hydrogen isotope loading by solid-state electrolysis at moderate temperatures 250−300 °C

    International Nuclear Information System (INIS)

    Fukada, Yoshiki; Hioki, Tatsumi; Motohiro, Tomoyoshi; Ohshima, Shigeki

    2015-01-01

    Hydrogen isotopes and metal interaction with respect to Pd under high hydrogen isotope potential at moderate temperature region around 300 °C was studied. A dry electrolysis technique using BaZr 1−x Y x O 3 solid state electrolyte was developed to generate high hydrogen isotope potential. Hydrogen or deuterium was loaded into a 200 nm thick Pd cathode. The cathode is deposited on SiO 2 substrate and covered with the solid state electrolyte and a Pd anode layer. Time resolved in situ monochromatic x-ray diffraction measurement was performed during the electrolysis. Two phase states of the Pd cathodes with large and small lattice parameters were observed during the electrolysis. Numerous sub-micron scale voids in the Pd cathode and dendrite-like Pd precipitates in the solid state electrolyte were found from the recovered samples. Hydrogen induced super-abundant-vacancy may take role in those phenomena. The observed two phase states may be attributed to phase separation into vacancy-rich and vacancy-poor states. The voids formed in the Pd cathodes seem to be products of vacancy coalescence. Isotope effects were also observed. The deuterium loaded samples showed more rapid phase changes and more formation of voids than the hydrogen doped samples. - Highlights: • High amount hydrogen loading into Pd by all solid-state electrolysis was performed. • Two phase states with large and small lattice parameters were observed. • Lattice contractions were observed suggesting formations of super-abundant-vacancy. • The absence of mechanical pressure might stimulate the formation of the vacancy. • Sub-micron void formations were found in the Pd from recovered samples

  19. Moderate Bravery

    DEFF Research Database (Denmark)

    Majgaard, Klaus

    2016-01-01

    Purpose: The ability to act in a purposeful and effective way amid institutional tensions and paradoxes is, right now, a highly prized quality in public leadership. The purpose of this chapter is to qualify moderately brave acts as a learning format that combines the analytical and performative...... skills implied in this kind of agency. Design/methodology/approach: The chapter explores the engagement with paradoxes as a narrative praxis. From existing literature, it sums up an understanding of agency as a social process of mediating paradoxes in order to make action possible. Drawing on Northrop...

  20. Load Measurements

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    The report describes Load measurements carried out on a given wind turbine. The aim of the measurement program regarding the loads on the turbine is to verify the basic characteristics of the wind turbine and loads on the blades, the rotor and the tower, using [Ref 1], [Ref2] and [Ref 3]. Regarding...... the fatigue loads, the rotor, blades and tower moments are presented. The fatigue loads are evaluated using rainflow counting described in detail in Ref. [1]. The 1Hz equivalent load ranges are calculated at different wind speeds. All information regarding the instrumentation is collected in [ref 4] and [ref...

  1. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  2. Moderator for nuclear reactor

    International Nuclear Information System (INIS)

    Milgram, M.S.; Dunn, J.T.; Hart, R.S.

    1995-01-01

    This invention relates to a moderator for a nuclear reactor and more specifically, to a composite moderator. A moderator is designed to slow down, or thermalize, neutrons which are released during nuclear reactions in the reactor fuel. Pure or almost pure materials like light water, heavy water, beryllium or graphite are used singly as moderators at present. All these materials, are used widely. Graphite has a good mechanical strength at high temperatures encountered in the nuclear core and therefore is used as both the moderator and core structural material. It also exhibits a low neutron-capture cross section and high neutron scattering cross section. However, graphite is susceptible to attach by carbon dioxide and/or oxygen where applicable, and releases stress energy under certain circumstances, although under normal operating conditions these reactions can be controlled. (author). 1 tab

  3. Coupled moderator neutronics

    International Nuclear Information System (INIS)

    Russell, G.J.; Pitcher, E.J.; Ferguson, P.D.

    1995-01-01

    Optimizing the neutronic performance of a coupled-moderator system for a Long-Pulse Spallation Source is a new and challenging area for the spallation target-system designer. For optimal performance of a neutron source, it is essential to have good communication with instrument scientists to obtain proper design criteria and continued interaction with mechanical, thermal-hydraulic, and materials engineers to attain a practical design. A good comprehension of the basics of coupled-moderator neutronics will aid in the proper design of a target system for a Long-Pulse Spallation Source

  4. Carbohydrate Loading.

    Science.gov (United States)

    Csernus, Marilyn

    Carbohydrate loading is a frequently used technique to improve performance by altering an athlete's diet. The objective is to increase glycogen stored in muscles for use in prolonged strenuous exercise. For two to three days, the athlete consumes a diet that is low in carbohydrates and high in fat and protein while continuing to exercise and…

  5. Den moderate revolution

    DEFF Research Database (Denmark)

    Larsen, Bøje

    "normale" industrivirksomheder, men den er absolut set begrænset. Årsagerne til denne kun "moderate revolution" af organisationsformerne diskuteres: Er det fordi klassisk organisation og social nærkontakt er nødvendig i den nye økonomi, eller er det manglende fantasi og tryghedsbehov? Begge muligheder...

  6. Cryogenic moderator design

    International Nuclear Information System (INIS)

    Diplock, B.R.

    1983-01-01

    This paper describes the present design of the two cold moderators to be built for the Spallation Neutron Source. It discusses the reasons behind a number of the design features and highlights several problem areas requiring solutions before a final design can be constructed

  7. Moderation of neutron energy

    International Nuclear Information System (INIS)

    Marlatt, G.R.

    1986-01-01

    This patent describes a nuclear reactor system having a nuclear reactor which has a core including fuel assemblies, means for transmitting through the core a coolant, the coolant having a predetermined neutron-energy moderating property, sealed tubes in the core, each tube containing a material having a different neutron-energy moderating property than the coolant, means, when actuated, to engage at least certain of the tubes, for opening certain of the tubes to permit the coolant to replace the material in the tubes thereby to change the energy spectrum of the neutrons in the reactor, hydraulic means, connected to the opening means, for actuating the opening means to engage certain of the tubes to open the tubes. A device, external to the reactor, connected to the hydraulic means controlls the actuation of the opening means, the opening means being so set with reference to the tubes that only certain of the tubes are opened at any time as the opening means is advanced towards the tubes by the hydraulic means

  8. Toward a Moderate Autoethnography

    Directory of Open Access Journals (Sweden)

    Sarah Stahlke Wall

    2016-10-01

    Full Text Available Autoethnography is an avant-garde method of qualitative inquiry that has captured the attention of an ever-increasing number of scholars from a variety of disciplines. Personal experience methods can offer a new and unique vantage point from which to make a contribution to social science yet, autoethnography has been criticized for being self-indulgent, narcissistic, introspective, and individualized. Methodological discussions about this method are polarized. As an autoethnographer and qualitative methodologist with an interest in personal experience methods, I have had the opportunity to review several autoethnographic manuscripts over the years. As my reviews accumulated, I began to see themes in my responses and it became apparent that I was advocating for an approach to autoethnography that lies in contrast to the frequently offered methodological polemics from philosophically divergent scholars. In this article, I draw from the reviews I have done to address topics such as applications and purposes for autoethnography, the degree of theory and analysis used within the method, data sources and dissemination of findings, and ethical issues. I then connect the concerns I see in the reviewed manuscripts to examples in the autoethnographic literature. Ultimately, I propose a moderate and balanced treatment of autoethnography that allows for innovation, imagination, and the representation of a range of voices in qualitative inquiry while also sustaining confidence in the quality, rigor, and usefulness of academic research.

  9. Thermal neutron moderating device

    International Nuclear Information System (INIS)

    Takigami, Hiroyuki.

    1995-01-01

    In a thermal neutron moderating device, superconductive coils for generating magnetic fields capable of applying magnetic fields vertical to the longitudinal direction of a thermal neutron passing tube, and superconductive coils for magnetic field gradient for causing magnetic field gradient in the longitudinal direction of the thermal neutron passing tube are disposed being stacked at the outside of the thermal neutron passing tube. When magnetic field gradient is present vertically to the direction of a magnetic moment, thermal neutrons undergo forces in the direction of the magnetic field gradient in proportion to the magnetic moment. Then, the magnetic moment of the thermal neutrons is aligned with the direction vertical to the passing direction of the thermal neutrons, to cause the magnetic field gradient in the passing direction of the thermal neutrons. The speed of the thermal neutrons can be optionally selected and the wavelength can freely be changed by applying forces to the thermal neutrons and changing the extent and direction of the magnetic field gradient. Superconductive coils are used as the coils for generating magnetic fields and the magnetic field gradient in order to change extremely high energy of the thermal neutrons. (N.H.)

  10. Electrical load detection aparatus

    DEFF Research Database (Denmark)

    2010-01-01

    A load detection technique for a load comprising multiple frequency-dependant sub-loads comprises measuring a representation of the impedance characteristic of the load; providing stored representations of a multiplicity of impedance characteristics of the load; each one of the stored representat...

  11. Distribution load estimation (DLE)

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A.; Lehtonen, M. [VTT Energy, Espoo (Finland)

    1998-08-01

    The load research has produced customer class load models to convert the customers` annual energy consumption to hourly load values. The reliability of load models applied from a nation-wide sample is limited in any specific network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to find improvements to the load models or, in general, improvements to the load estimates. In Distribution Load Estimation (DLE) the measurements from the network are utilized to improve the customer class load models. The results of DLE will be new load models that better correspond to the loading of the distribution network but are still close to the original load models obtained by load research. The principal data flow of DLE is presented

  12. Moderate Secularism and Multicultural Equality

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2008-01-01

    Tariq Modood argues that European states are only ‘moderately secular' and that this kind of secularism is compatible with public accommodation of religious groups and provides a model of Muslim integration appropriate for European states. Although attention to the fact of moderate secularism pro...... a normative conception of equality, but his characterisation of multicultural equality is inadequate in several respects...

  13. Moderator Configuration Options for ESS

    DEFF Research Database (Denmark)

    Zanini, L.; Batkov, K.; Klinkby, Esben Bryndt

    2016-01-01

    conventional, principles were also considered,such as the importance of moderator positioning, of the premoderator, and beam extraction considerations. Different design and configuration options are evaluated and compared with the reference volume moderator configuration described in the ESS Technical Design...

  14. Doing statistical mediation and moderation

    CERN Document Server

    Jose, Paul E

    2013-01-01

    Written in a friendly, conversational style, this book offers a hands-on approach to statistical mediation and moderation for both beginning researchers and those familiar with modeling. Starting with a gentle review of regression-based analysis, Paul Jose covers basic mediation and moderation techniques before moving on to advanced topics in multilevel modeling, structural equation modeling, and hybrid combinations, such as moderated mediation. User-friendly features include numerous graphs and carefully worked-through examples; ""Helpful Suggestions"" about procedures and pitfalls; ""Knowled

  15. Moderate Secularism and Multicultural Equality

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2008-01-01

    Tariq Modood argues that European states are only ‘moderately secular' and that this kind of secularism is compatible with public accommodation of religious groups and provides a model of Muslim integration appropriate for European states. Although attention to the fact of moderate secularism...... provides a response to a prominent argument against multicultural accommodation of religious minorities, what is really at stake in discussions of multiculturalism and secularism are political principles. Modood's case for accommodation of Muslims along the lines of moderate secularism presupposes...

  16. Plutonium immobilization -- Can loading

    International Nuclear Information System (INIS)

    Kriikku, E.

    2000-01-01

    The Savannah River Site (SRS) will immobilize excess plutonium in the proposed Plutonium Immobilization Project (PIP). The PIP adds the excess plutonium to ceramic pucks, loads the pucks into cans, and places the cans into DWPF canisters. This paper discusses the PIP process steps, the can loading conceptual design, can loading equipment design, and can loading work completed

  17. Neutron moderation theory with thermal motion of the moderator nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Rusov, V.D.; Tarasov, V.A.; Chernezhenko, S.A.; Kakaev, A.A.; Smolyar, V.P. [Odessa National Polytechnic University, Department of Theoretical and Experimental Nuclear Physics, Odessa (Ukraine)

    2017-09-15

    In this paper we present the analytical expression for the neutron scattering law for an isotropic source of neutrons, obtained within the framework of the gas model with the temperature of the moderating medium as a parameter. The obtained scattering law is based on the solution of the general kinematic problem of elastic scattering of neutrons on nuclei in the L-system. Both the neutron and the nucleus possess arbitrary velocities in the L-system. For the new scattering law we obtain the flux densities and neutron moderation spectra as functions of temperature for the reactor fissile medium. The expressions for the moderating neutrons spectra allow reinterpreting the physical nature of the underlying processes in the thermal region. (orig.)

  18. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  19. A liquid nitrogen cooled polyethylene moderator for the Harwell Linac

    International Nuclear Information System (INIS)

    Boland, B.C.; Hey, P.D.; Houzego, P.J.; Mack, B.; Mildner, D.F.R.; Sinclair, R.N.

    1978-09-01

    A 40 mm thick polyethylene block has been maintained at a temperature close to 80 K by using a liquid nitrogen cryostat, and used to moderate neutrons from pulsed source. The assembly has been tested with a dummy heat load of 400W. The cryostat and cooling system was installed on the Harwell 45 MeV electron linac, and enabled the production of sharper pulses in the thermal neutron energy range. The design, safety considerations and performance are described. (author)

  20. Sagittal plane lumbar loading when navigating an obstacle and carrying a load.

    Science.gov (United States)

    Kiriella, Jeevaka B; Perry, Carolyn J; Hawkins, Kara M; Shanahan, Camille J; Gage, William H; Moore, Anne E

    2016-11-01

    The current study quantified lumbar loading while carrying an anterior load mass and navigating an obstacle. Eight healthy male participants walked down a walkway and crossed an obstacle under three randomised LOAD conditions; empty-box (2 KG), five kilogram (5 KG) and ten kilogram (10 KG). Each walk was assessed at two events: left foot mid-stance (LMS) and right toe-crossing (TC) to characterise any changes from approach to crossing. Measures of interest included: trunk pitch, L4/L5 joint moment, compression, joint anterior-posterior shear and erector spinae activation. Findings demonstrate that obstacle crossing extended posture by 50, 41, 44%, respectively for each carried load magnitude. Further, these results indicate that shear rather than compressive loading may be an important consideration during crossing due to increase by 8, 9, 22% from LMS to TC for each load magnitude tested. These results provide insight into sagittal lumbar loading when navigating an obstacle while carrying a load. Practitioner Summary: The risk of carrying while navigating obstacles on the lumbar spine is not completely understood. The forces at the lumbar spine while simultaneously carrying and obstacle crossing were analysed. Data indicate that carrying and obstacle crossing influence lumbar shear loads, thereby moderately increasing the relative risk at lumbar spine.

  1. Graphite moderated 252Cf source

    International Nuclear Information System (INIS)

    Sajo B, L.; Barros, H.; Greaves, E. D.; Vega C, H. R.

    2014-08-01

    The thorium molten salt reactor is an attractive and affordable nuclear power option for developing countries with insufficient infrastructure and limited technological capability. In the aim of personnel training and experience gathering at the Universidad Simon Bolivar there is in progress a project of developing a subcritical thorium liquid fuel reactor. The neutron source to run this subcritical reactor is a 252 Cf source and the reactor will use high-purity graphite as moderator. Using the MCNP5 code the neutron spectra of the 252 Cf in the center of the graphite moderator has been estimated along the channel where the liquid thorium salt will be inserted; also the ambient dose equivalent due to the source has been determined around the moderator. (Author)

  2. Radicals versus Moderates: A Critique of Gyekye's Moderate ...

    African Journals Online (AJOL)

    The communitarian conception of person is a widely accepted view in African thought. Kwame Gyekye thinks there is a distinction between what he calls radical communitarianism and his own version of moderate communitarianism. He is of the view that radical communitarianism is faced with insurmountable problems and ...

  3. Wind Loads on Structures

    DEFF Research Database (Denmark)

    Dyrbye, Claes; Hansen, Svend Ole

    Wind loads have to be taken into account when designing civil engineering structures. The wind load on structures can be systematised by means of the wind load chain: wind climate (global), terrain (wind at low height), aerodynamic response (wind load to pressure), mechanical response (wind...... pressure to structural response) and design criteria. Starting with an introduction of the wind load chain, the book moves on to meteorological considerations, atmospheric boundary layer, static wind load, dynamic wind load and scaling laws used in wind-tunnel tests. The dynamic wind load covers vibrations...... induced by wind turbulence, vortex shedding, flutter and galloping. The book gives a comprehensive treatment of wind effects on structures and it will be useful for consulting engineers designing wind-sensitive structures. It will also be valuable for students of civil engineering as textbook...

  4. Autonomous Propellant Loading Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Autonomous Propellant Loading (APL) project consists of three activities. The first is to develop software that will automatically control loading of...

  5. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  6. Critical experiments on enriched uranium graphite moderated cores

    International Nuclear Information System (INIS)

    Kaneko, Yoshihiko; Akino, Fujiyoshi; Kitadate, Kenji; Kurokawa, Ryosuke

    1978-07-01

    A variety of 20 % enriched uranium loaded and graphite-moderated cores consisting of the different lattice cells in a wide range of the carbon to uranium atomic ratio have been built at Semi-Homogeneous Critical Experimental Assembly (SHE) to perform the critical experiments systematically. In the present report, the experimental results for homogeneously or heterogeneously fuel loaded cores and for simulation core of the experimental reactor for a multi-purpose high temperature reactor are filed so as to be utilized for evaluating the accuracy of core design calculation for the experimental reactor. The filed experimental data are composed of critical masses of uranium, kinetic parameters, reactivity worths of the experimental control rods and power distributions in the cores with those rods. Theoretical analyses are made for the experimental data by adopting a simple ''homogenized cylindrical core model'' using the nuclear data of ENDF/B-III, which treats the neutron behaviour after smearing the lattice cell structure. It is made clear from a comparison between the measurement and the calculation that the group constants and fundamental methods of calculations, based on this theoretical model, are valid for the homogeneously fuel loaded cores, but not for both of the heterogeneously fuel loaded cores and the core for simulation of the experimental reactor. Then, it is pointed out that consideration to semi-homogeneous property of the lattice cells for reactor neutrons is essential for high temperature graphite-moderated reactors using dispersion fuel elements of graphite and uranium. (author)

  7. Limit loads in nozzles

    International Nuclear Information System (INIS)

    Zouain, N.

    1983-01-01

    The static method for the evaluation of the limit loads of a perfectly elasto-plastic structure is presented. Using the static theorem of Limit Analysis and the Finite Element Method, a lower bound for the colapso load can be obtained through a linear programming problem. This formulation if then applied to symmetrically loaded shells of revolution and some numerical results of limit loads in nozzles are also presented. (Author) [pt

  8. Moderate Muslims Myth or Reality

    National Research Council Canada - National Science Library

    Salcedo, Carmia L

    2007-01-01

    ..., that is non-violent, and that is properly suited for the 21st Century? Western public discourse on Islamic terrorism is rife with appeals to "moderate Muslims" to condemn terrorists and their so-called hijacking of the Islamic religion...

  9. Moderate deviations for bounded subsequences

    Directory of Open Access Journals (Sweden)

    George Stoica

    2006-01-01

    Full Text Available We study Davis' series of moderate deviations probabilities for Lp-bounded sequences of random variables (p>2. A certain subseries therein is convergent for the same range of parameters as in the case of martingale difference or i.i.d. sequences.

  10. Risk, Causation, Mediation, and Moderation

    Science.gov (United States)

    Kumsta, Robert; Rutter, Michael; Stevens, Suzanne; Sonuga-Barke, Edmund J.

    2010-01-01

    Throughout this monograph, there has been frequent reference to levels of risk, inference of causation, testing for mediating variables, and the need to consider possible moderating influences. In this chapter, the authors review what is meant by these concepts, and then seek to pull together the findings from the English and Romanian Adoptee…

  11. Cognitive Load and Cooperation

    DEFF Research Database (Denmark)

    Døssing, Felix Sebastian; Piovesan, Marco; Wengström, Erik Roland

    2017-01-01

    We study the effect of intuitive and reflective processes on cooperation using cognitive load. Compared with time constraint, which has been used in the previous literature, cognitive load is a more direct way to block reflective processes, and thus a more suitable way to study the link between...... intuition and cooperation. Using a repeated public goods game, we study the effect of different levels of cognitive load on contributions. We show that a higher cognitive load increases the initial level of cooperation. In particular, subjects are significantly less likely to fully free ride under high...... cognitive load....

  12. Spatial electric load forecasting

    CERN Document Server

    Willis, H Lee

    2002-01-01

    Spatial Electric Load Forecasting Consumer Demand for Power and ReliabilityCoincidence and Load BehaviorLoad Curve and End-Use ModelingWeather and Electric LoadWeather Design Criteria and Forecast NormalizationSpatial Load Growth BehaviorSpatial Forecast Accuracy and Error MeasuresTrending MethodsSimulation Method: Basic ConceptsA Detailed Look at the Simulation MethodBasics of Computerized SimulationAnalytical Building Blocks for Spatial SimulationAdvanced Elements of Computerized SimulationHybrid Trending-Simulation MethodsAdvanced

  13. Nuclear data generation for cryogenic moderators and high temperature moderators

    International Nuclear Information System (INIS)

    Petriw, Sergio

    2007-01-01

    The commonly used processing codes for nuclear data only allow the generation of cross section data for a limited number of materials and physical conditions.At present, one of the most used computer codes for the generation of neutron cross sections is N J O Y, which is based on a phonon expansion of the scattering function starting from the frequency spectrum.Therefore, the information related to the system's density of states is crucial to produce the required data of interest. In this work the formalism of the Synthetic Model for Molecular Solids (S M M S) was implemented, which is in turn based on the Synthetic Frequency Spectrum (S F S) concept.The synthetic spectrum is central in the present work, and it is built from simple, relevant parameters of the moderator, thus conforming an alternative tool when no information on the actual frequency spectrum of the moderator material is available.S F S 's for several material of interest where produced in this work, for both cryogenic and high temperature moderators.We studied some materials of special interest, like solid methane, ice, methyl clathrate and two which are of special interest in the nuclear industry: graphite and beryllium.The libraries generated in the present work for the materials considered, in spite of their synthetic origin, are able to produce results that are even in better agreement with available information [es

  14. Acute emesis: moderately emetogenic chemotherapy

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Rapoport, Bernardo; Warr, David

    2011-01-01

    receiving multiple cycles of moderately emetogenic chemotherapy will be reviewed. Consensus statements are given, including optimal dose and schedule of serotonin(3) receptor antagonists, dexamethasone, and neurokinin(1) receptor antagonists. The most significant recommendations (and changes since the 2004...... version of the guidelines) are as follows: the best prophylaxis in patients receiving moderately emetogenic chemotherapy (not including a combination of an anthracycline plus cyclophosphamide) is the combination of palonosetron and dexamethasone on the day of chemotherapy, followed by dexamethasone...... on days 2-3. In patients receiving a combination of an anthracycline plus cyclophosphamide, a combination of a serotonin(3) receptor antagonist plus dexamethasone, plus the neurokinin(1) receptor antagonist aprepitant on the day of chemotherapy, followed by aprepitant days 2-3, is recommended....

  15. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  16. Cryogenic moderator simulations: confronting reality

    International Nuclear Information System (INIS)

    Iverson, E. B.

    1999-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a spallation neutron source dedicated to materials research. Its three cryogenic methane moderators provide twelve neutron beams to fourteen instruments and test facilities. This report concerns ongoing activities for benchmarking our Monte Carlo model of the IPNS neutron generation system. This paper concentrates on the techniques (both experimental and calculational) used in such benchmarking activities

  17. Reflector-moderated critical assemblies

    International Nuclear Information System (INIS)

    Paxton, H.C.; Jarvis, G.A.; Byers, C.C.

    1975-07-01

    Experiments with reflector-moderated critical assemblies were part of the Rover Program at the Los Alamos Scientific Laboratory (LASL). These assemblies were characterized by thick D 2 O or beryllium reflectors surrounding large cavities that contained highly enriched uranium at low average densities. Because interest in this type of system has been revived by LASL Plasma Cavity Assembly studies, more detailed descriptions of the early assemblies than had been available in the unclassified literature are provided. (U.S.)

  18. Moderate and extreme maternal obesity.

    LENUS (Irish Health Repository)

    Abdelmaboud, M O

    2012-05-01

    The aim of this study was to investigate the prevalence of moderate and extreme obesity among an Irish obstetric population over a 10-year period, and to evaluate the obstetric features of such pregnancies. Of 31,869 women delivered during the years 2000-2009, there were 306 women in the study group, including 173 in the moderate or Class 2 obese category (BMI 35-39.9) and 133 in the extreme or Class 3 obese category (BMI > or = 40).The prevalence of obese women with BMI > or = 35 was 9.6 per 1000 (0.96%), with an upward trend observed from 2.1 per 1000 in the year 2000, to 11.8 per 1000 in the year 2009 (P = 0.001). There was an increase in emergency caesarean section (EMCS) risk for primigravida versus multigravid women, within both obese categories (P < 0.001). However, there was no significant difference in EMCS rates observed between Class 2 and Class 3 obese women, when matched for parity. The prevalence of moderate and extreme obesity reported in this population is high, and appears to be increasing. The increased rates of abdominal delivery, and the levels of associated morbidity observed, have serious implications for such women embarking on pregnancy.

  19. Laterally loaded masonry

    DEFF Research Database (Denmark)

    Raun Gottfredsen, F.

    In this thesis results from experiments on mortar joints and masonry as well as methods of calculation of strength and deformation of laterally loaded masonry are presented. The strength and deformation capacity of mortar joints have been determined from experiments involving a constant compressive...... stress and increasing shear. The results show a transition to pure friction as the cohesion is gradually destroyed. An interface model of a mortar joint that can take into account this aspect has been developed. Laterally loaded masonry panels have also been tested and it is found to be characteristic...... that laterally loaded masonry exhibits a non-linear load-displacement behaviour with some ductility....

  20. Electrical load modeling

    Energy Technology Data Exchange (ETDEWEB)

    Valgas, Helio Moreira; Pinto, Roberto del Giudice R.; Franca, Carlos [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Lambert-Torres, Germano; Silva, Alexandre P. Alves da; Pires, Robson Celso; Costa Junior, Roberto Affonso [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1994-12-31

    Accurate dynamic load models allow more precise calculations of power system controls and stability limits, which are critical mainly in the operation planning of power systems. This paper describes the development of a computer program (software) for static and dynamic load model studies using the measurement approach for the CEMIG system. Two dynamic load model structures are developed and tested. A procedure for applying a set of measured data from an on-line transient recording system to develop load models is described. (author) 6 refs., 17 figs.

  1. Concentrated loads on concrete

    DEFF Research Database (Denmark)

    Lorenzen, Karen Grøndahl; Nielsen, Mogens Peter

    1997-01-01

    This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas are devel......This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas...

  2. Load regulating expansion fixture

    International Nuclear Information System (INIS)

    Wagner, L.M.; Strum, M.J.

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located there between. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig

  3. Electronic Load Bank

    Science.gov (United States)

    Huston, Steven W.

    1992-01-01

    Electronic load-bank circuit provides pulsed or continuous low-resistance load to imitate effect of short circuit on Ni/H2 or other electrochemical power cells. Includes safety/warning feature and taps for measurement of cell-output voltage and current.

  4. Load Balancing in Hypergraphs

    Science.gov (United States)

    Delgosha, Payam; Anantharam, Venkat

    2018-03-01

    Consider a simple locally finite hypergraph on a countable vertex set, where each edge represents one unit of load which should be distributed among the vertices defining the edge. An allocation of load is called balanced if load cannot be moved from a vertex to another that is carrying less load. We analyze the properties of balanced allocations of load. We extend the concept of balancedness from finite hypergraphs to their local weak limits in the sense of Benjamini and Schramm (Electron J Probab 6(23):13, 2001) and Aldous and Steele (in: Probability on discrete structures. Springer, Berlin, pp 1-72, 2004). To do this, we define a notion of unimodularity for hypergraphs which could be considered an extension of unimodularity in graphs. We give a variational formula for the balanced load distribution and, in particular, we characterize it in the special case of unimodular hypergraph Galton-Watson processes. Moreover, we prove the convergence of the maximum load under some conditions. Our work is an extension to hypergraphs of Anantharam and Salez (Ann Appl Probab 26(1):305-327, 2016), which considered load balancing in graphs, and is aimed at more comprehensively resolving conjectures of Hajek (IEEE Trans Inf Theory 36(6):1398-1414, 1990).

  5. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  6. LIGHT WATER MODERATED NEUTRONIC REACTOR

    Science.gov (United States)

    Christy, R.F.; Weinberg, A.M.

    1957-09-17

    A uranium fuel reactor designed to utilize light water as a moderator is described. The reactor core is in a tank at the bottom of a substantially cylindrical cross-section pit, the core being supported by an apertured grid member and comprised of hexagonal tubes each containing a pluralily of fuel rods held in a geometrical arrangement between end caps of the tubes. The end caps are apertured to permit passage of the coolant water through the tubes and the fuel elements are aluminum clad to prevent corrosion. The tubes are hexagonally arranged in the center of the tank providing an amulus between the core and tank wall which is filled with water to serve as a reflector. In use, the entire pit and tank are filled with water in which is circulated during operation by coming in at the bottom of the tank, passing upwardly through the grid member and fuel tubes and carried off near the top of the pit, thereby picking up the heat generated by the fuel elements during the fission thereof. With this particular design the light water coolant can also be used as the moderator when the uranium is enriched by fissionable isotope to an abundance of U/sup 235/ between 0.78% and 2%.

  7. Playing Moderately Hard to Get

    Directory of Open Access Journals (Sweden)

    Stephen Reysen

    2013-12-01

    Full Text Available In two studies, we examined the effect of different degrees of attraction reciprocation on ratings of attraction toward a potential romantic partner. Undergraduate college student participants imagined a potential romantic partner who reciprocated a low (reciprocating attraction one day a week, moderate (reciprocating attraction three days a week, high (reciprocating attraction five days a week, or unspecified degree of attraction (no mention of reciprocation. Participants then rated their degree of attraction toward the potential partner. The results of Study 1 provided only partial support for Brehm’s emotion intensity theory. However, after revising the high reciprocation condition vignette in Study 2, supporting Brehm’s emotion intensity theory, results show that a potential partners’ display of reciprocation of attraction acted as a deterrent to participants’ intensity of experienced attraction to the potential partner. The results support the notion that playing moderately hard to get elicits more intense feelings of attraction from potential suitors than playing too easy or too hard to get. Discussion of previous research examining playing hard to get is also re-examined through an emotion intensity theory theoretical lens.

  8. An advanced cold moderator using solid methane pellets

    International Nuclear Information System (INIS)

    Foster, C.A.; Carpenter, J.M.

    2001-01-01

    This paper reports developments of the pellet formation and transport technologies required for producing a liquid helium or hydrogen cooled methane pellet moderator. The Phase I US DOE SBIR project, already completed, demonstrated the production of 3 mm transparent pellets of frozen methane and ammonia and transport of the pellets into a 40 cc observation cell cooled with liquid helium. The methane pellets, formed at 72 K, stuck together during the loading of the cell. Ammonia pellets did not stick and fell readily under vibration into a packed bed with a 60% fill fraction. A 60% fill fraction should produce a very significant increase in long-wavelength neutron production and advantages in shorter pulse widths as compared to a liquid hydrogen moderator. The work also demonstrated a method of rapidly changing the pellets in the moderator cell. The Phase II project, just now underway, will develop a full-scale pellet source and transport system with a 1.5 L 'moderator' cell. The Phase II effort will also produce an apparatus to sub-cool the methane pellets to below 20 K, which should prevent the methane pellets from sticking together. In addition to results of the phase I experiments, the presentation includes a short video of the pellets, and a description of plans for the Phase II project. (author)

  9. Load flow analysis using decoupled fuzzy load flow under critical ...

    African Journals Online (AJOL)

    user

    The conventional load flow methods like Newton-Raphson load flow (NRLF), Fast Decoupled load flow (FDLF) provide poor performance under critical conditions such as high R/X ratio, heavily loading condition etc. Exploiting the decoupling properties of power system, reliable fuzzy load flow is developed to overcome the ...

  10. HUD Low and Moderate Income Areas

    Data.gov (United States)

    Department of Housing and Urban Development — This dataset and map service provides information on the U.S. Housing and Urban Development's (HUD) low to moderate income areas. The term Low to Moderate Income,...

  11. Load Balancing Scientific Applications

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Olga Tkachyshyn [Texas A & M Univ., College Station, TX (United States)

    2014-12-01

    The largest supercomputers have millions of independent processors, and concurrency levels are rapidly increasing. For ideal efficiency, developers of the simulations that run on these machines must ensure that computational work is evenly balanced among processors. Assigning work evenly is challenging because many large modern parallel codes simulate behavior of physical systems that evolve over time, and their workloads change over time. Furthermore, the cost of imbalanced load increases with scale because most large-scale scientific simulations today use a Single Program Multiple Data (SPMD) parallel programming model, and an increasing number of processors will wait for the slowest one at the synchronization points. To address load imbalance, many large-scale parallel applications use dynamic load balance algorithms to redistribute work evenly. The research objective of this dissertation is to develop methods to decide when and how to load balance the application, and to balance it effectively and affordably. We measure and evaluate the computational load of the application, and develop strategies to decide when and how to correct the imbalance. Depending on the simulation, a fast, local load balance algorithm may be suitable, or a more sophisticated and expensive algorithm may be required. We developed a model for comparison of load balance algorithms for a specific state of the simulation that enables the selection of a balancing algorithm that will minimize overall runtime.

  12. Low to moderate temperature nanolaminate heater

    Science.gov (United States)

    Eckels, J Del [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Hau-Riege, Stefan [Fremont, CA; Walton, Chris [Oakland, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA

    2011-01-11

    A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

  13. Load research manual. Volume 3. Load research for advanced technologies

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

  14. Static Loads Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides the capability to perform large-scale structural loads testing on spacecraft and other structures. Results from these tests can be used to verify...

  15. Influence of wind loading

    OpenAIRE

    MAVLONOV RAVSHANBEK ABDUJABBOROVICH; VAKKASOV KHAYRULLO SAYFULLAHANOVICH

    2015-01-01

    Each wind load is determined by a probabilistic-statistical method based on the concept of “equivalent static wind load”, on the assumption that structural frames and components/cladding behave elastically in strong wind.

  16. Plug Load Data

    Data.gov (United States)

    National Aeronautics and Space Administration — We provide MATLAB binary files (.mat) and comma separated values files of data collected from a pilot study of a plug load management system that allows for the...

  17. Lumbriculus variegatus loading study

    Data.gov (United States)

    U.S. Environmental Protection Agency — Results from sediment bioaccumulation tests with Lumbriculus variegatus with evaluating the effects of organism loading density. This dataset is associated with the...

  18. LOADING SIMULATION PROGRAM C

    Science.gov (United States)

    LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for simulating hydrology, sediment, and general water quality

  19. Lumbosacral loads in bedmaking.

    Science.gov (United States)

    Milburn, P D; Barrett, R S

    1999-06-01

    The purpose of this study was to determine whether the introduction of larger and heavier beds which were lower to the floor increased the physical stress on employees responsible for room cleaning and bedmaking in the hospitality industry. More specifically, this study assessed the effect of bed size (single, double and king) and bed height (460 and 560 mm) on dynamic and static estimates of L5/S1 compression force and static L5/S1 shear force for six simulated components of the overall bedmaking task. Results confirmed the view that static models severely underestimate the loads on the lumbar spine under inertial lifting conditions, and also indicated that: (i) tasks with the greatest hand loads were not necessarily associated with the greatest spinal loads due to differences in the way each task was performed; (ii) L5/S1 loads produced during bedmaking may exceed recommended safe lifting limits for certain task-size height combinations; and (iii) the use of larger and heavier beds in the hospitality industry imposes increased loads on the lumbar spine. The investigation of alternative work practices designed to minimise loads on the lumbar spine is recommended.

  20. Performance analysis of dynamic load balancing algorithm for multiprocessor interconnection network

    Directory of Open Access Journals (Sweden)

    M.U. Bokhari

    2016-09-01

    Full Text Available Multiprocessor interconnection network have become powerful parallel computing system for real-time applications. Nowadays the many researchers posses studies on the dynamic load balancing in multiprocessor system. Load balancing is the method of dividing the total load among the processors of the distributed system to progress task's response time as well as resource utilization whereas ignoring a condition where few processors are overloaded or underloaded or moderately loaded. However, in dynamic load balancing algorithm presumes no priori information about behaviour of tasks or the global state of the system. There are numerous issues while designing an efficient dynamic load balancing algorithm that involves utilization of system, amount of information transferred among processors, selection of tasks for migration, load evaluation, comparison of load levels and many more. This paper enlightens the performance analysis on dynamic load balancing strategy (DLBS algorithm, used for hypercube network in multiprocessor system.

  1. Load power device, system and method of load control and management employing load identification

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  2. Load rating of complex bridges.

    Science.gov (United States)

    2010-07-01

    The National Bridge Inspection Standards require highway departments to inspect, evaluate, and determine load ratings for : structures defined as bridges located on all public roads. Load rating of bridges is performed to determine the live load that...

  3. The Effect of Aging and Mechanical Loading on the Metabolism of Articular Cartilage

    DEFF Research Database (Denmark)

    Jørgensen, Adam El Mongy; Kjaer, Michael; Heinemeier, Katja Maria

    2017-01-01

    , with the literature search made on PubMed using appropriate keywords regarding AC, age, and mechanical loading. Results. Following skeletal maturation, chondrocyte numbers decline while increasing senescence occurs. Lower cartilage turnover causes diminished maintenance capacity, which produces accumulation......Objective. The morphology of articular cartilage (AC) enables painless movement. Aging and mechanical loading are believed to influence development of osteoarthritis (OA), yet the connection remains unclear. Methods. This narrative review describes the current knowledge regarding this area...... of fibrillar crosslinks by advanced glycation end products, resulting in increased stiffness and thereby destruction susceptibility. Conclusion. Mechanical loading changes proteoglycan content. Moderate mechanical loading causes hypertrophy and reduced mechanical loading causes atrophy. Overloading produces...

  4. The effect og aging and mechanical loading on the metabolism og articular cartilage

    DEFF Research Database (Denmark)

    Jørgensen, Adam El Mongy; Kjær, Michael; Heinemeier, Katja Maria

    2017-01-01

    , with the literature search made on PubMed using appropriate keywords regarding AC, age, and mechanical loading. Results. Following skeletal maturation, chondrocyte numbers decline while increasing senescence occurs. Lower cartilage turnover causes diminished maintenance capacity, which produces accumulation......Objective. The morphology of articular cartilage (AC) enables painless movement. Aging and mechanical loading are believed to influence development of osteoarthritis (OA), yet the connection remains unclear. Methods. This narrative review describes the current knowledge regarding this area...... of fibrillar crosslinks by advanced glycation end products, resulting in increased stiffness and thereby destruction susceptibility. Conclusion. Mechanical loading changes proteoglycan content. Moderate mechanical loading causes hypertrophy and reduced mechanical loading causes atrophy. Overloading produces...

  5. Wave Loads on Cylinders

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Frigaard, Peter

    1989-01-01

    Wave loads may be defined as time varying forces on a body resulting from the wave induced flow fields which surrounds the body in whole or in part. Such unsteady fluid forces are the net result of pressure and shear forces integrated over the instantaneous wetted area.......Wave loads may be defined as time varying forces on a body resulting from the wave induced flow fields which surrounds the body in whole or in part. Such unsteady fluid forces are the net result of pressure and shear forces integrated over the instantaneous wetted area....

  6. New moderator for pulsed neutron diffraction

    International Nuclear Information System (INIS)

    Mayer, R.E.; Granada, J.R.; Gillette, V.H.; Dawidowski, J.

    1989-01-01

    Experiments of neutron diffraction, leakage spectrum and pulse decay have been carried out on a new geometry, heterogeneously poisoned, set of moderators and on conventional sandwich and slab moderators for comparison purposes. For a given time pulse width, great increase in neutron leakage intensity has been found in these assemblies, up to 2.7 times that of a sandwich moderator. Clues to implementation of desired time-response in moderator design and of further increases in neutron yields are suggested by present results. 8 refs., 4 figs., 1 tab

  7. High efficiency moderator for pulsed neutron diffraction

    International Nuclear Information System (INIS)

    Mayer, R.E.; Granada, J.R.; Gillette, V.H.; Dawidowski, J.

    1990-01-01

    Moderators consisting of clusters of smaller slow-neutron-decoupled moderating elements were tested through experiments of pulsed neutron diffraction, leakage spectrum measurement, and neutron pulse decay. A simple slab and a thin 'sandwich' moderator were also measured for comparison purposes. For a given time width of the neutron pulse in the usual wavelength range for neutron diffraction, the proposed assembly produced a much higher neutron yield. Clues to the implementation of the desired time-response in moderator design and optimization are suggested by the present results. (orig.)

  8. Moderate Resolution Imaging Spectroradiometer (MODIS) - Terra

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset represents multiple products archived at the multiple archive centers for the MODIS (Moderate Resolution Imaging Spectroradiometer) instrument aboard...

  9. Moderate Resolution Imaging Spectroradiometer (MODIS) - Aqua

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset represents multiple products archived at the multiple archive centers for the MODIS (Moderate Resolution Imaging Spectroradiometer) instrument aboard...

  10. Lateral loadings on snubber assemblies

    International Nuclear Information System (INIS)

    Raphael, L.S.

    1981-01-01

    This paper examines the installation of snubber assemblies in power plants with respect to transverse or lateral loads as well as axial loads. Evaluation of the effects of low level, lateral loads was performed by analytical means. At higher loadings, the snubber assembly could no longer be treated as a column; therefore, the effects of lateral loadings was determined by test. The test consisted of applying both lateral and axial loads simultaneously. Results of both the analysis and the test showed that the application of lateral loads had a considerable effect on the snubber assemblies

  11. Load research and load estimation in electricity distribution

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland). Energy Systems

    1996-12-31

    The topics introduced in this thesis are: the Finnish load research project, a simple form customer class load model, analysis of the origins of customers load distribution, a method for the estimation of the confidence interval of customer loads and Distribution Load Estimation (DLE) which utilises both the load models and measurements from distribution networks. The Finnish load research project started in 1983. The project was initially coordinated by the Association of Finnish Electric Utilities and 40 utilities joined the project. Now there are over 1000 customer hourly load recordings in a database. A simple form customer class load model is introduced. The model is designed to be practical for most utility applications and has been used by the Finnish utilities for several years. The only variable of the model is the customers annual energy consumption. The model gives the customers average hourly load and standard deviation for a selected month, day and hour. The statistical distribution of customer loads is studied and a model for customer electric load variation is developed. The model results in a lognormal distribution as an extreme case. Using the `simple form load model`, a method for estimating confidence intervals (confidence limits) of customer hourly load is developed. The two methods selected for final analysis are based on normal and lognormal distribution estimated in a simplified manner. The estimation of several cumulated customer class loads is also analysed. Customer class load estimation which combines the information from load models and distribution network load measurements is developed. This method, called Distribution Load Estimation (DLE), utilises information already available in the utilities databases and is thus easy to apply

  12. Robust surgery loading

    NARCIS (Netherlands)

    Hans, Elias W.; Wullink, Gerhard; van Houdenhoven, Mark; Kazemier, Geert

    2008-01-01

    We consider the robust surgery loading problem for a hospital’s operating theatre department, which concerns assigning surgeries and sufficient planned slack to operating room days. The objective is to maximize capacity utilization and minimize the risk of overtime, and thus cancelled patients. This

  13. Probabilistic Load Flow

    DEFF Research Database (Denmark)

    Chen, Peiyuan; Chen, Zhe; Bak-Jensen, Birgitte

    2008-01-01

    This paper reviews the development of the probabilistic load flow (PLF) techniques. Applications of the PLF techniques in different areas of power system steady-state analysis are also discussed. The purpose of the review is to identify different available PLF techniques and their corresponding...

  14. Dynamic power load simulator

    Science.gov (United States)

    Joncas, K. P.; Birnbach, S.; Lambert, M., III

    1973-01-01

    Two independent models simulate dynamic and steady-state responses of electrical and electronic equipment under power load. One is resistance/capacitance/inductance network, and the other is variable resistance analog device. Resistance, inductance, and/or capacitance are selected by iterative process; time-domain response is compared with that of real equipment to select optimal values.

  15. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  16. Associated lesions of peri-implant mucosa in immediate versus delayed loading of dental implants.

    Science.gov (United States)

    Iliescu, Alexandru Andrei; Zurac, Sabina Andrada; Nicolae, Vasile; Iliescu, Mihaela Georgiana; Perlea, Paula

    2017-01-01

    Currently, immediate loading of dental implants is very attractive as a standard protocol for prosthetic restorations in edentulous patients. The aim of this study is to find out the intimate peri-implant mucosa response depending on timing of implant loading, immediate or delayed. Fifty-one screw implants Alpha Bio (Alpha-Bio Tec, Israel) were inserted in 42 partially edentulous patients according to standardized surgical techniques. At six months of loading, samples of peri-implant mucosa were harvested from 27 immediate loaded, respectively 24 delayed loaded implants, and subjected to microscopic examination. Peri-implant mucosa in both loadings revealed a continuous and stable stratified squamous epithelium with moderate acanthosis and slight hyperkeratosis. Severe fibrosis and tendency to scar-like lesions were present mainly in immediate loading. Slight to moderate density of inflammatory chronic cell populations of non-uniform feature was common to both loading protocols. As compared to lymphocytes, higher scores of plasma cells were encountered in immediate loading. In immediate and delayed loading, the peri-implant mucosa as a new generated structure does not reveal different tissue responses. After six month of prosthetic loading, the healthy peri-implant mucosa is compatible with fibrosis and minor chronic inflammatory reactions.

  17. Pharmacodynamic considerations for moderate and deep sedation.

    Science.gov (United States)

    Becker, Daniel E

    2012-01-01

    Moderate and deep sedation can be provided using various classes of drugs, each having unique mechanisms of action. While drugs within a given classification share similar mechanisms and effects, certain classes demonstrate superior efficacy but added concern regarding safety. This continuing education article will highlight essential principles of pharmacodynamics and apply these to drugs commonly used to produce moderate and deep sedation.

  18. Integrating Mediators and Moderators in Research Design

    Science.gov (United States)

    MacKinnon, David P.

    2011-01-01

    The purpose of this article is to describe mediating variables and moderating variables and provide reasons for integrating them in outcome studies. Separate sections describe examples of moderating and mediating variables and the simplest statistical model for investigating each variable. The strengths and limitations of incorporating mediating…

  19. Global differences between moderate and large storms

    Science.gov (United States)

    Valek, P. W.; Buzulukova, N.; Fok, M. C. H.; Goldstein, J.; Keesee, A. M.; McComas, D. J.; Perez, J. D.

    2015-12-01

    The current solar maximum has been relatively quiet compared to previous solar cycles. Whereas numerous moderate storms (Dst minutes). Here we will present the differences seen between moderate storms and the two large storms of 17 March 2015 (Dst 30 keV) and high (30 to > 100 keV) energy ranges, and describe how the inner magnetosphere evolves during storm time.

  20. Understanding and Using Mediators and Moderators

    Science.gov (United States)

    Wu, Amery D.; Zumbo, Bruno D.

    2008-01-01

    Mediation and moderation are two theories for refining and understanding a causal relationship. Empirical investigation of mediators and moderators requires an integrated research design rather than the data analyses driven approach often seen in the literature. This paper described the conceptual foundation, research design, data analysis, as…

  1. Moderate Secularism, Difference Sensitivity and Contextualism

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2009-01-01

    The article is a rejoinder to Tariq Modood's reply (Politics, Vol. 29, No. 1, 2009) to my article 'Moderate Secularism and Multicultural Equality' (Politics, Vol 28, No. 3, 2008).......The article is a rejoinder to Tariq Modood's reply (Politics, Vol. 29, No. 1, 2009) to my article 'Moderate Secularism and Multicultural Equality' (Politics, Vol 28, No. 3, 2008)....

  2. The Effect of Load Stabilizer Selection on Load Shift Within Unit Loads

    OpenAIRE

    Bisha, James Victor

    2008-01-01

    Research on unit load stability aids manufacturing facilities in selecting the most efficient load stabilizer when shipping their products to market. This studyâ s objective was to compare the performance a variety of different commonly used load stabilizers to stretch hooding. Stretch hooding is a method of load stabilization in which a tubular film is heat sealed at the top, stretched by four mechanical arms to a desired width, pulled down over the unit load. The film is slowly released...

  3. Duration of load revisited

    DEFF Research Database (Denmark)

    Hoffmeyer, Preben; Sørensen, John Dalsgaard

    2007-01-01

    to bending under constant load condi-tions. Two constant moisture conditions (MC = 11 % and 20 %) and one condition of varying moisture (MC between 11 % and 20 %) were applied. A total of 816 Norway spruce boards of dimensions 44 x 95 x 1800 mm were included. Eight groups of non-destructively matched samples......A duration of load study representing 13 years of testing was recently terminated. Preliminary results have been published over the years. This paper represents the final account of the study, which was focused on the influ-ence of moisture content on time to failure for structural timber subjected...... were formed. Four groups were subjected to short-term strength tests, and four groups were subjected to long-term tests. Creep and time to failure were moni-tored. Time to failure as a function of stress level was established and the reliability of stress level assessment was discussed. A significant...

  4. Heavy-Load Lifting

    DEFF Research Database (Denmark)

    Bloomquist, Kira; Oturai, Peter; Steele, Megan L

    2018-01-01

    PURPOSE: Despite a paucity of evidence, prevention guidelines typically advise avoidance of heavy lifting in an effort to protect against breast cancer-related lymphedema. This study compared acute responses in arm swelling and related symptoms after low- and heavy-load resistance exercise among...... women at risk of lymphedema while receiving adjuvant taxane-based chemotherapy. METHODS: This is a randomized, cross-over equivalence trial. Women receiving adjuvant taxane-based chemotherapy for breast cancer who had undergone axillary lymph node dissection (n=21) participated in low- (60-65% 1...... repetition maximum (RM), two sets of 15-20 repetitions) and heavy-load (85-90% 1RM, three sets of 5-8 repetition) upper-extremity resistance exercise separated by a one-week wash-out period. Swelling was determined by bioimpedance spectroscopy and dual energy x-ray absorptiometry, with breast cancer...

  5. A cryogenic moderator system for JESSICA, a test facility for advanced cold moderators

    International Nuclear Information System (INIS)

    Stelzer, H.; Bayer, N.; Hinssen, H.K.; Matzerath, Th.

    2004-01-01

    In this article we like to report on building up and running a cryogenic moderator system for JESSICA, a full scale model of the target-reflector-moderator system for the European spallation source (ESS). The cryogenic moderator system can be charged with different fluids, solids and pellets in fluids at cryogenic temperatures. (orig.)

  6. Methods for Integrating Moderation and Mediation: A General Analytical Framework Using Moderated Path Analysis

    Science.gov (United States)

    Edwards, Jeffrey R.; Lambert, Lisa Schurer

    2007-01-01

    Studies that combine moderation and mediation are prevalent in basic and applied psychology research. Typically, these studies are framed in terms of moderated mediation or mediated moderation, both of which involve similar analytical approaches. Unfortunately, these approaches have important shortcomings that conceal the nature of the moderated…

  7. Fuel element loading system

    International Nuclear Information System (INIS)

    Arya, S.P; s.

    1978-01-01

    A nuclear fuel element loading system is described which conveys a plurality of fuel rods to longitudinal passages in fuel elements. Conveyor means successively position the fuel rods above the longitudinal passages in axial alignment therewith and adapter means guide the fuel rods from the conveyor means into the longitudinal passages. The fuel elements are vibrated to cause the fuel rods to fall into the longitudinal passages through the adapter means

  8. Load responsive hydrodynamic bearing

    Science.gov (United States)

    Kalsi, Manmohan S.; Somogyi, Dezso; Dietle, Lannie L.

    2002-01-01

    A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

  9. Plastic limit loads for cylindrical shell intersections under combined loading

    International Nuclear Information System (INIS)

    Skopinsky, V.N.; Berkov, N.A.; Vogov, R.A.

    2015-01-01

    In this research, applied methods of nonlinear analysis and results of determining the plastic limit loads for shell intersection configurations under combined internal pressure, in-plane moment and out-plane moment loadings are presented. The numerical analysis of shell intersections is performed using the finite element method, geometrically nonlinear shell theory in quadratic approximation and plasticity theory. For determining the load parameter of proportional combined loading, the developed maximum criterion of rate of change of relative plastic work is employed. The graphical results for model of cylindrical shell intersection under different two-parameter combined loadings (as generalized plastic limit load curves) and three-parameter combined loading (as generalized plastic limit load surface) are presented on the assumption that the internal pressure, in-plane moment and out-plane moment loads were applied in a proportional manner. - Highlights: • This paper presents nonlinear two-dimensional FE analysis for shell intersections. • Determining the plastic limit loads under combined loading is considered. • Developed maximum criterion of rate of change of relative plastic work is employed. • Plastic deformation mechanism in shell intersections is discussed. • Results for generalized plastic limit load curves of branch intersection are presented

  10. NORMATIVE MODERATORS OF IMPULSE BUYING BEHAVIOR

    Directory of Open Access Journals (Sweden)

    Danes Jaya Negara

    2003-01-01

    Full Text Available Prior research has presented the moderating role of normative evaluations in the relationship between the impulsive buying trait and consumers’ buying behaviors. In this article the authors show that consumer tendency to buy something spontaneous, unreflectively and immediately can be perceived as a factor which describes buying impulsiveness. This article also shows conceptual and empirical evidence that there is some support for the moderating role of normative evaluations in the relationship between buying impulsiveness and impulse buying behaviors. Significance occurs when consumers believe that act on impulse is suitable. The result suggests that consumers’ normative evaluation can moderate the link between the trait and behavioral aspects of impulse buying.

  11. Neutron moderators for the European Spallation Source

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Zanini, L.; Batkov, K.

    The design of the neutron moderators for the European Spallation Source, intended to be installed at the start of operations of the facility in 2019 has now been finalized and the moderators are being fabricated. Among the driving principles in the design have been flexibility for instruments...... to have access to cold and thermal neutrons with highest possible source brightness. Different design and configuration options were evaluated. The final configuration accepted for construction foresees two moderators with identical para-hydrogen (so-called "butterfly") shape, but different heights...

  12. JACKETED FUEL ELEMENTS FOR GRAPHITE MODERATED REACTORS

    Science.gov (United States)

    Szilard, L.; Wigner, E.P.; Creutz, E.C.

    1959-05-12

    Fuel elements for a heterogeneous, fluid cooled, graphite moderated reactor are described. The fuel elements are comprised of a body of natural uranium hermetically sealed in a jacket of corrosion resistant material. The jacket, which may be aluminum or some other material which is non-fissionable and of a type having a low neutron capture cross-section, acts as a barrier between the fissioning isotope and the coolant or moderator or both. The jacket minimizes the tendency of the moderator and coolant to become radioactive and/or contaminated by fission fragments from the fissioning isotope.

  13. Trailing Vortex-Induced Loads During Close Encounters in Cruise

    Science.gov (United States)

    Mendenhall, Michael R.; Lesieutre, Daniel J; Kelly, Michael J.

    2015-01-01

    The trailing vortex induced aerodynamic loads on a Falcon 20G business jet flying in the wake of a DC-8 are predicted to provide a preflight estimate of safe trail distances during flight test measurements in the wake. Static and dynamic loads on the airframe flying in the near wake are shown at a matrix of locations, and the dynamic motion of the Falcon 20G during traverses of the DC-8 primary trailing vortex is simulated. Safe trailing distances for the test flights are determined, and optimum vortex traverse schemes are identified to moderate the motion of the trailing aircraft during close encounters with the vortex wake.

  14. Nutrient and Coliform Loading (NCL)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is a database of available fecal coliform bacteria, fecal streptococci bacteria, and nutrient loading data. Loading for contaminants other than fecal coliform...

  15. Structural Impact of Construction Loads

    OpenAIRE

    McPheron, Daniel; McCullouch, Bob; Bowman, Mark D.

    2012-01-01

    Numerous bridge construction accidents have occurred across the country because of construction loadings, which are an under-emphasized topic in many DOT specifications and design manuals. Bridge girders are least stable when they are subjected to construction loads, so it is important for design engineers and contractors to understand and design for these loads. The Indiana Department of Transportation’s current Standard Specifications does not contain many construction load provisions, so t...

  16. Nutritional Recovery Outcome among Moderately Malnourished ...

    African Journals Online (AJOL)

    Nutritional Recovery Outcome among Moderately Malnourished Under-five Children in Communities Implementing Positive Deviance - Hearth or Community Health Workers' Nutrition Promotion Approaches in Karusi and Kirundo Provinces, Burundi.

  17. TMD Evolution at Moderate Hard Scales

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Ted [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Old Dominion Univ., Norfolk, VA (United States); Collins, John C. [Pennsylvania State Univ., University Park, PA (United States)

    2016-01-01

    We summarize some of our recent work on non-perturbative transverse momentum dependent (TMD) evolution, emphasizing aspects that are necessary for dealing with moderately low scale processes like semi-inclusive deep inelastic scattering.

  18. Moderate drinking : No impact on female fecundity

    NARCIS (Netherlands)

    Zaadstra, B.M.; Looman, C.W.N.; Velde, E.R. te; Habbema, J.D.F.; Karbaat, J.

    1994-01-01

    Objective: To determine the effect of moderate alcohol intake on probability of conception. Design: Prospective cohort study. Setting: Normal healthy women enrolled in an artificial donor insemination program. Patients: Women starting artificial donor insemination for the very first time were

  19. Advanced Neutron Moderators for the ESS

    DEFF Research Database (Denmark)

    Schönfeldt, Troels

    , which generates an interest in moderator development. Many facilities have proposed and applied advanced moderator concepts to better utilize the produced neutrons. The topic of this thesis is the study of these advanced moderator concepts. Chapters 1 to 6 briefly summarize the historical development......Thermal and cold neutrons are used in a wide array of different experiments investigating the sub-micrometer properties of matter. Neutrons are typically produced at reactor or spallation sources and subsequently cooled to the wanted thermal or cold energy levels by employing neutron moderators....... Today these sources are still the most intense neutron sources. The short-pulsed sources SNS and J-PARC are the most powerful spallation sources in the world; although less intense than ILL and HFIR, these sources provide more useful neutrons because of their pulsed beam structure. This thesis focuses...

  20. Control of finger forces during fast, slow and moderate rotational hand movements.

    Science.gov (United States)

    Kazemi, Hamed; Kearney, Robert E; Milner, Theodore E

    2014-01-01

    The goal of this study was to investigate the effect of speed on patterns of grip forces during twisting movement involving forearm supination against a torsional load (combined elastic and inertial load). For slow and moderate speed rotations, the grip force increased linearly with load torque. However, for fast rotations in which the contribution of the inertia to load torque was significantly greater than slower movements, the grip force-load torque relationship could be segmented into two phases: a linear ascending phase corresponding to the acceleration part of the movement followed by a plateau during deceleration. That is, during the acceleration phase, the grip force accurately tracked the combined elastic and inertial load. However, the coupling between grip force and load torque was not consistent during the deceleration phase of the movement. In addition, as speed increased, both the position and the force profiles became smoother. No differences in the baseline grip force, safety margin to secure the grasp during hold phase or the overall change in grip force were observed across different speeds.

  1. Moderate Deviations for Recursive Stochastic Algorithms

    Science.gov (United States)

    2014-08-02

    There are also results for martingale di¤erences such as Dembo [9], Gao [16], and Djellout [11]. For various reasons, the issues previously mentioned...deviations approach to design and analysis. Stoch. Proc. Appl., 119:562� 587, 2009. [9] A. Dembo. Moderate deviations for martingales with bounded jumps...H. Djellout. Moderate deviations for martingale di¤erences and applic- ations to -mixing sequences. Stoch. Stoch. Rep., 73:37�63, 2002. [12] P

  2. Demand Response Load Following of Source and Load Systems

    DEFF Research Database (Denmark)

    Hu, Jianqiang; Cao, Jinde; Yong, Taiyou

    2017-01-01

    This paper presents a demand response load following strategy for an interconnected source and load system, in which we utilize traditional units and population of cooling thermostatically controlled loads (TCLs) to follow the mismatched power caused by the load activities and the renewable power...... injection in real time. In the demand side of power systems, these TCLs are often affiliated to a bus load agent and can be aggregated to multiple TCL aggregators. Firstly, aggregate evaluation of the TCL aggregator is carried out based on a bilinear aggregate model so as to derive the available regulation...... capacities and regulation rates of aggregators. Based on the evaluation results, the dispatch center optimizes the real time load following trajectories for the generating units and the flexible load agents via look-ahead optimization by considering the injection of renewable power. Furthermore, we mainly...

  3. Android Fully Loaded

    CERN Document Server

    Huddleston, Rob

    2012-01-01

    Fully loaded with the latest tricks and tips on your new Android! Android smartphones are so hot, they're soaring past iPhones on the sales charts. And the second edition of this muscular little book is equally impressive--it's packed with tips and tricks for getting the very most out of your latest-generation Android device. Start Facebooking and tweeting with your Android mobile, scan barcodes to get pricing and product reviews, download your favorite TV shows--the book is positively bursting with practical and fun how-tos. Topics run the gamut from using speech recognition, location-based m

  4. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  5. Microbial Load Monitor

    Science.gov (United States)

    Gibson, S. F.; Royer, E. R.

    1979-01-01

    The Microbial Load Monitor (MLM) is an automated and computerized system for detection and identification of microorganisms. Additionally, the system is designed to enumerate and provide antimicrobic susceptibility profiles for medically significant bacteria. The system is designed to accomplish these tasks in a time of 13 hours or less versus the traditional time of 24 hours for negatives and 72 hours or more for positives usually required for standard microbiological analysis. The MLM concept differs from other methods of microbial detection in that the system is designed to accept raw untreated clinical samples and to selectively identify each group or species that may be present in a polymicrobic sample.

  6. CFD simulations of moderator flow inside Calandria of the Passive Moderator Cooling System of an advanced reactor

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Eshita [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India); Kumar, Mukesh [Reactor Engineering Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India); Joshi, Jyeshtharaj B., E-mail: jbjoshi@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India); Department of Chemical Engineering, Institute of Chemical Technology, Matunga, Mumbai 400019 India (India); Nayak, Arun K. [Reactor Engineering Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India); Vijayan, Pallippattu K., E-mail: vijayanp@barc.gov.in [Reactor Engineering Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India)

    2015-10-15

    Highlights: • CFD simulations in the Calandria of an advanced reactor under natural circulation. • Under natural convection, majority of the flow recirculates within the Calandria. • Maximum temperature is located at the top and center of the fuel channel matrix. • During SBO, temperature inside Calandria is stratified. - Abstract: Passive systems are being examined for the future Advanced Nuclear Reactor designs. One of such concepts is the Passive Moderator Cooling System (PMCS), which is designed to remove heat from the moderator in the Calandria vessel passively in case of an extended Station Black Out condition. The heated heavy-water moderator (due to heat transferred from the Main Heat Transport System (MHTS) and thermalization of neutrons and gamma from radioactive decay of fuel) rises upward due to buoyancy, gets cooled down in a heat exchanger and returns back to Calandria, completing a natural circulation loop. The natural circulation should provide sufficient cooling to prevent the increase of moderator temperature and pressure beyond safe limits. In an earlier study, a full-scale 1D transient simulation was performed for the reactor including the MHTS and the PMCS, in the event of a station blackout scenario (Kumar et al., 2013). The results indicate that the systems remain within the safe limits for 7 days. However, the flow inside a geometry like Calandria is quite complex due to its large size and inner complexities of dense fuel channel matrix, which was simplified as a 1D pipe flow in the aforesaid analysis. In the current work, CFD simulations are performed to study the temperature distributions and flow distribution of moderator inside the Calandria vessel using a three-dimensional CFD code, OpenFoam 2.2.0. First, a set of steady state simulation was carried out for a band of inlet mass flow rates, which gives the minimum mass flow rate required for removing the maximum heat load, by virtue of prediction of hot spots inside the Calandria

  7. Preformulation Characterisation, Designing and Formulation of Aceclofenac Loaded Microparticles

    OpenAIRE

    B. Jayanthi; S. Madhusudhan; G. P. Mohanta; P.K. Manna

    2012-01-01

    The purpose of the present study was to systematically investigate some of the important physicochemical properties of Aceclofenac loaded micro particles.Aceclofenac is a potent analgesic, anti-pyretic and anti-inflammatory agent used in the management of moderate-to-severe pain and in rheumatoid disorder, rheumatoid arthritis and ankylosing spondylities. Almost all drugs are marketed as tablets, capsules or both. Prior to the development of these major dosage forms, it is essential that pert...

  8. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  9. Ankle Joint Contact Loads and Displacement With Progressive Syndesmotic Injury.

    Science.gov (United States)

    Hunt, Kenneth J; Goeb, Yannick; Behn, Anthony W; Criswell, Braden; Chou, Loretta

    2015-09-01

    Ligamentous injuries to the distal tibiofibular syndesmosis are predictive of long-term ankle dysfunction. Mild and moderate syndesmotic injuries are difficult to stratify, and the impact of syndesmosis injury on the magnitude and distribution of forces within the ankle joint during athletic activities is unknown. Eight below-knee cadaveric specimens were tested in the intact state and after sequential sectioning of the following ligaments: anterior-inferior tibiofibular, anterior deltoid (1 cm), interosseous/transverse (IOL/TL), posterior-inferior tibiofibular, and whole deltoid. In each condition, specimens were loaded in axial compression to 700 N and then externally rotated to 20 N·m torque. During axial loading and external rotation, both the fibula and the talus rotated significantly after each ligament sectioning as compared to the intact condition. After IOL/TL release, a significant increase in posterior translation of the fibula was observed, although no syndesmotic widening was observed. Mean tibiotalar contact pressure increased significantly after IOL/TL release, and the center of pressure shifted posterolaterally, relative to more stable conditions, after IOL/TL release. There were significant increases in mean contact pressure and peak pressure along with a reduction in contact area with axial loading and external rotation as compared to axial loading alone for all 5 conditions. Significant increases in tibiotalar contact pressures occur when external rotation stresses are added to axial loading. Moderate and severe injuries are associated with a significant increase in mean contact pressure combined with a shift in the center of pressure and rotation of the fibula and talus. Considerable changes in ankle joint kinematics and contact mechanics may explain why moderate syndesmosis injuries take longer to heal and are more likely to develop long-term dysfunction and, potentially, ankle arthritis. © The Author(s) 2015.

  10. High thermal load component

    International Nuclear Information System (INIS)

    Fuse, Toshiaki; Tachikawa, Nobuo.

    1996-01-01

    A cooling tube made of a pure copper is connected to the inner portion of an armour (heat resistant member) made of an anisotropic carbon/carbon composite (CFC) material. The CFC material has a high heat conductivity in longitudinal direction of fibers and has low conductivity in perpendicular thereto. Fibers extending in the armour from a heat receiving surface just above the cooling tube are directly connected to the cooling tube. A portion of the fibers extending from a heat receiving surface other than portions not just above the cooling tube is directly bonded to the cooling tube. Remaining fibers are disposed so as to surround the cooling tube. The armour and the cooling tube are soldered using an active metal flux. With such procedures, high thermal load components for use in a thermonuclear reactor are formed, which are excellent in a heat removing characteristic and hardly causes defects such as crackings and peeling. (I.N.)

  11. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis.

    Science.gov (United States)

    Bozkaya, Dincer; Muftu, Sinan; Muftu, Ali

    2004-12-01

    The external contour of an implant and the magnitude of occlusal loading can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant systems. The goal of this study was to investigate the effects of external geometry and occlusal load magnitude on bone failure modes for 5 commercially available dental implant systems. Five different implant systems; Ankylos, Astra, Bicon, ITI, and Nobel Biocare, comparable in size, but different in thread profile and crest module shapes, were compared using the finite element method. Type II bone quality was approximated and complete osseous integration was assumed. Occlusal loads of varying magnitudes (0 to 2000 N) were applied on the abutments supporting single tooth restorations at 11.3 degrees from the vertical axis with a 1-mm offset. Total overloaded bone area, where tensile and compressive normal stresses fell outside of the recommended limits of 100 and 170 MPa, respectively, was investigated for different load levels. For moderate levels of occlusal loads up to 300 N, the compact bone was not overloaded by any of the implant systems. At the extreme end of the occlusal load range (1000 N or more) the overloading characteristics of implants may be dependent on geometric shape. In general, overloading occurs near the superior region of compact bone, in compression, and it is primarily caused by the normal and lateral components of the occlusal load. At the region of intersection of compact and trabecular bone, overloading occurs in tension due to the vertical component of the occlusal load. For excessive forces greater than 1000 N, the overloaded areas of the bone varied considerably among 5 different implants systems evaluated.

  12. Graphite moderated {sup 252}Cf source

    Energy Technology Data Exchange (ETDEWEB)

    Sajo B, L.; Barros, H.; Greaves, E. D. [Universidad Simon Bolivar, Nuclear Physics Laboratory, Apdo. 89000, 1080A Caracas (Venezuela, Bolivarian Republic of); Vega C, H. R., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-08-15

    The thorium molten salt reactor is an attractive and affordable nuclear power option for developing countries with insufficient infrastructure and limited technological capability. In the aim of personnel training and experience gathering at the Universidad Simon Bolivar there is in progress a project of developing a subcritical thorium liquid fuel reactor. The neutron source to run this subcritical reactor is a {sup 252}Cf source and the reactor will use high-purity graphite as moderator. Using the MCNP5 code the neutron spectra of the {sup 252}Cf in the center of the graphite moderator has been estimated along the channel where the liquid thorium salt will be inserted; also the ambient dose equivalent due to the source has been determined around the moderator. (Author)

  13. The case for moderate gun control.

    Science.gov (United States)

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  14. IQ as a moderator of outcome in severity of children’s mental health status after treatment in outpatient clinics

    Directory of Open Access Journals (Sweden)

    Mathiassen Børge

    2012-06-01

    Full Text Available Abstract Background Psychotherapy is an effective treatment for mental health disorders, but even with the most efficacious treatment, many patients do not experience improvement. Moderator analysis can identify the conditions under which treatment is effective or whether there are factors that can attenuate the effects of treatment. Methods In this study, linear mixed model analysis was used to examine whether the Full Scale IQ (FSIQ, Performance IQ (PIQ and Verbal IQ (VIQ on the Wechsler Intelligence Scale for Children – Third Edition, moderated outcomes in general functioning and symptom load. A total of 132 patients treated at three outpatient child and adolescent mental health services (CAMHS were assessed at three different time points. The Children’s Global Assessment Scale (CGAS and the Health of the Nation Outcome Scales for Children and Adolescents (HoNOSCA were used to measure the severity of impairments in general functioning and symptom load. IQ was assessed at the start of treatment. Results Moderator analysis revealed that the FSIQ × time interaction predicted changes in CGAS scores (p p  Conclusions FISQ and PIQ moderated change in general functioning and symptom load, respectively. This implies that patients with higher IQ scores had a steeper improvement slope than those with lower scores. The patients with the highest initial symptom loads showed the greatest improvement, this pattern was not found in the improvement of general functioning.

  15. Examining Moderate Volatile Loss through Lunar History

    Science.gov (United States)

    Saxena, Prabal; Killen, Rosemary M.; Airapetian, Vladimir; Petro, Noah; Mandell, Avi

    2017-06-01

    While the Moon and bulk silicate earth (BSE) share many compositional similarities, a notable difference is the apparent depletion of moderate volatiles in lunar samples. Depletion of elements such as sodium and potassium relative to BSE composition has been observed in Apollo samples. The source of these depletions is poorly understood but may be a result of preferential accretion of volatile-rich melt in the inner disk to the Earth during Moon formation.However, recent Kepler data has indicated that stellar analogues to our Sun experience enhanced flare activity early in their evolution. This implies that the Sun may have had a higher frequency and energy of flares and associated Coronal Mass Ejections (CME) in its distant past. We examine the potential impacts of this increased activity on lunar exosphere generation and specifically on potential loss of moderate volatiles including sodium and potassium.We use a surface bounded exosphere model that incorporates multiple processes including photon stimulated desorption, kinetic sputtering and impact vaporization in order to study potential moderate volatile loss under a variety of different conditions. This model is informed by appropriate solar wind and CME properties, which includes CMEs of different energies. We also incorporate regolith overturn to determine ranges of potential bulk depletion of moderate volatiles from the lunar regolith.Our work is aimed at determining the potential impact of solar activity on the depletion of moderate volatiles in the lunar regolith. Such a contribution is important to ascertain in order to isolate the depletion of volatiles due to disk processes and may thus help constrain details of the Moon's formation. Finally, we also examine the potential of lunar abundances of moderate volatiles as an observational tracer of past solar activity.

  16. Moderator Demonstration Facility Design and Optimization

    Energy Technology Data Exchange (ETDEWEB)

    McClanahan, Tucker C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gallmeier, Franz X. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Iverson, Erik B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-02-01

    The Spallation Neutron Source (SNS) facility at Oak Ridge National Laboratory (ORNL) is implementing a Moderator Demonstration Facility (MDF) to demonstrate the performance characteristics of advanced moderators central to the Second Target Station (STS) for SNS. The MDF will use the "spare" front-end installation within the SNS accelerator support complex – an ion source, radio-frequency quadrupole (RFQ) accelerator, and medium-energy beam transport (MEBT) chopper - to provide a 2.5 MeV proton beam of peak current 50 mA and maximum pulse length of less than 10 s at a repetition rate of no more than 60 Hz to a suitable neutron-producing target to demonstrate those aspects of moderator performance necessary to meet the goals of the STS design e ort. The accelerator beam parameters are not open to variation beyond that described above - they are fixed by the nature of the spare front-end installation (the Integrated Test Stand Facility; ITSF). Accordingly, there are some neutronic challenges in developing prototypic moderator illumination from a very non-prototypic primary neutron source; the spallation source we are attempting to mimic has an extended neutron source volume approximately 40 cm long (in the direction of the proton beam), approximately 10 cm wide (horizontally transverse to the proton beam) and approximately 5 cm high (vertically transverse to the proton beam), and an isotropic evaporation energy spectrum with mean energy above 1 MeV. In contrast, the primary neutron source available from the 7Li(p,n) reaction (the most prolific at 2.5 MeV proton energy by more than an order of magnitude) is strongly anisotropic, with an energy spectrum that is both strongly dependent on emission angle and kinematically limited to less than 700 keV, and the interaction zone between the incident protons and any target material (neutron-producing or not) is intrinsically limited to a few tens of microns. The MDF will be unique and innovative amongst the world

  17. Load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Aalborg Nielsen, Henrik

    This report presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. The load for refrigeration is the sum of all cabinets in the supermarket, both low and medium temperature cabinets, and spans a period of one year. As input to the forecasting models the ambient temperature observed near the supermarket together with weather forecasts are used. Every hour...... the hourly load for refrigeration for the following 42 hours is forecasted. The forecast models are adaptive linear time-series models which are fitted with a computationally efficient recursive least squares scheme. The dynamic relations between the inputs and the load is modeled by simple transfer...

  18. Testing Machine for Biaxial Loading

    Science.gov (United States)

    Demonet, R. J.; Reeves, R. D.

    1985-01-01

    Standard tensile-testing machine applies bending and tension simultaneously. Biaxial-loading test machine created by adding two test fixtures to commercial tensile-testing machine. Bending moment applied by substrate-deformation fixture comprising yoke and anvil block. Pneumatic tension-load fixture pulls up on bracket attached to top surface of specimen. Tension and deflection measured with transducers. Modified test apparatus originally developed to load-test Space Shuttle surface-insulation tiles and particuarly important for composite structures.

  19. The effect of inspiratory muscle training on respiratory and limb locomotor muscle deoxygenation during exercise with resistive inspiratory loading.

    OpenAIRE

    Turner, Louise; Tecklenburg-Lund, S.L.; Chapman, R.; Shei, R.J.; Wilhite, D.P.; Mickleborough, T.

    2016-01-01

    We investigated how inspiratory muscle training impacted respiratory and locomotor muscle deoxygenation during submaximal exercise with resistive inspiratory loading. 16 male cyclists completed 6 weeks of either true (n=8) or sham (n=8) inspiratory muscle training. Pre- and post-training, subjects completed 3, 6-min experimental trials performed at ~80%  ˙VO2peak with interventions of either moderate inspiratory loading, heavy inspiratory loading, or maximal exercise imposed in the final 3 mi...

  20. Effectiveness of eye armor during blast loading.

    Science.gov (United States)

    Bailoor, Shantanu; Bhardwaj, Rajneesh; Nguyen, Thao D

    2015-11-01

    Ocular trauma is one of the most common types of combat injuries resulting from the interaction of military personnel with improvised explosive devices. Ocular blast injury mechanisms are complex, and trauma may occur through various injury mechanisms. However, primary blast injuries (PBI) are an important cause of ocular trauma that may go unnoticed and result in significant damage to internal ocular tissues and visual impairment. Further, the effectiveness of commonly employed eye armor, designed for ballistic and laser protection, in lessening the severity of adverse blast overpressures (BOP) is unknown. In this paper, we employed a three-dimensional (3D) fluid-structure interaction computational model for assessing effectiveness of the eye armor during blast loading on human eyes and validated results against free field blast measurements by Bentz and Grimm (2013). Numerical simulations show that the blast waves focused on the ocular region because of reflections from surrounding facial features and resulted in considerable increase in BOP. We evaluated the effectiveness of spectacles and goggles in mitigating the pressure loading using the computational model. Our results corroborate experimental measurements showing that the goggles were more effective than spectacles in mitigating BOP loading on the eye. Numerical results confirmed that the goggles significantly reduced blast wave penetration in the space between the armor and the eyes and provided larger clearance space for blast wave expansion after penetration than the spectacles. The spectacles as well as the goggles were more effective in reducing reflected BOP at higher charge mass because of the larger decrease in dynamic pressures after the impact. The goggles provided greater benefit of reducing the peak pressure than the spectacles for lower charge mass. However, the goggles resulted in moderate, sustained elevated pressure loading on the eye, that became 50-100% larger than the pressure loading

  1. Alaska Village Electric Load Calculator

    Energy Technology Data Exchange (ETDEWEB)

    Devine, M.; Baring-Gould, E. I.

    2004-10-01

    As part of designing a village electric power system, the present and future electric loads must be defined, including both seasonal and daily usage patterns. However, in many cases, detailed electric load information is not readily available. NREL developed the Alaska Village Electric Load Calculator to help estimate the electricity requirements in a village given basic information about the types of facilities located within the community. The purpose of this report is to explain how the load calculator was developed and to provide instructions on its use so that organizations can then use this model to calculate expected electrical energy usage.

  2. Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

    International Nuclear Information System (INIS)

    Rossi, Pierre; Boulay, Claude; Tailhan, Jean-Louis; Martin, Eric; Desnoyers, Dominic

    2014-01-01

    This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack

  3. daily nigerian nigerian nigerian peak load forec peak load forec

    African Journals Online (AJOL)

    User

    The anticipated load demand is perhaps the mo vital information for the planning and operati of an electric power utility. Accurate models f electric power load forecasting are essential to the operation and planning of a util company. Basic operating functions such as u commitment, economic dispatch, fuel scheduli and unit ...

  4. Golimumab for moderate to severe ulcerative colitis

    NARCIS (Netherlands)

    Strik, Anne S.; Berends, Sophie E.; Mathôt, Ron A.; D'Haens, Geert R.; Löwenberg, Mark

    2017-01-01

    Golimumab (GLM) is a subcutaneously administered human anti-tumor necrosis factor (TNF) agent that has been approved by the regulatory authorities for the treatment of moderate to severe ulcerative colitis (UC) in 2013. Areas covered: Maintained clinical remission rates up to 50% have been shown in

  5. Moderate takes key science role in Congress

    CERN Multimedia

    MacIlwain, C

    2001-01-01

    Sherry Boehlert has been named as chair of the Science committee in the US House of Representatives. Described as a moderate Republican with a keen interest in environmental and energy issues, it is seen as a good appointment by scientists (1/2 page)

  6. developing and implementing assessment moderation procedures

    African Journals Online (AJOL)

    Temechegn

    discrepancies in marking lab reports and brought significant improvements on students' motivation and achievements. .... What is the effect of assessment through moderation on students' learning and motivation? ..... Conclusion: This is a brief paragraph where you: restate your objective, quote data that proves you met or ...

  7. Solar and Interplanetary Disturbances causing Moderate ...

    Indian Academy of Sciences (India)

    Abstract. The effect of solar and interplanetary disturbances on geo- magnetospheric conditions leading to 121 moderate geomagnetic storms. (MGS) have been investigated using the neutron monitor, solar geophysical and interplanetary data during the period 1978–99. Further, the duration of recovery phase has been ...

  8. Solar and Interplanetary Disturbances causing Moderate ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Keywords. Solar flares; active prominences and disappearing filaments; sunspot numbers; geomagnetic storms. Abstract. The effect of solar and interplanetary disturbances on geomagnetospheric conditions leading to 121 moderate geomagnetic storms (MGS) have been investigated using the neutron ...

  9. Crane-Load Contact Sensor

    Science.gov (United States)

    Youngquist, Robert; Mata, Carlos; Cox, Robert

    2005-01-01

    An electronic instrument has been developed as a prototype of a portable crane-load contact sensor. Such a sensor could be helpful in an application in which the load rests on a base in a horizontal position determined by vertical alignment pins (see Figure 1). If the crane is not positioned to lift the load precisely vertically, then the load can be expected to swing once it has been lifted clear of the pins. If the load is especially heavy, large, and/or fragile, it could hurt workers and/or damage itself and nearby objects. By indicating whether the load remains in contact with the pins when it has been lifted a fraction of the length of the pins, the crane-load contact sensor helps the crane operator determine whether it is safe to lift the load clear of the pins: If there is contact, then the load is resting against the sides of the pins and, hence, it may not be safe to lift; if contact is occasionally broken, then the load is probably not resting against the pins, so it should be safe to lift. It is assumed that the load and base, or at least the pins and the surfaces of the alignment holes in the load, are electrically conductive, so the instrument can use electrical contact to indicate mechanical contact. However, DC resistance cannot be used as an indicator of contact for the following reasons: The load and the base are both electrically grounded through cables (the load is grounded through the lifting cable of the crane) to prevent discharge of static electricity. In other words, the DC resistance between the load and the pins is always low, as though they were always in direct contact. Therefore, instead of DC resistance, the instrument utilizes the AC electrical impedance between the pins and the load. The signal frequency used in the measurement is high enough (.1 MHz) that the impedance contributed by the cables and the electrical ground network of the building in which the crane and the base are situated is significantly greater than the contact

  10. Drivers and moderators of business decline

    Directory of Open Access Journals (Sweden)

    Marius Pretorius

    2010-12-01

    Full Text Available Purpose: Reports of business failure elicit various reactions, while research in this domain often appears to be limited by a lack of access to information about failure and by the negativity that surrounds it. Those who have experienced failure do not readily talk about it, or they disappear from the radar screen of researchers. Yet failure is preceded by decline which, when focused on strategically, can reduce eventual failures if early action is taken. The main purpose of this study is to develop a conceptual framework or typology of the drivers and moderators of business decline. Design/methodology/approach: After applying the "grounded theory" approach to the academic literature on decline and failure, a conceptual framework for the variables that drive and moderate business decline is proposed. Findings: The study proposes that decline has three core drivers, three peripheral drivers and four moderators. The core drivers identified are: resource munificence; leadership as origin; and causality (strategic versus operational origin of decline. The three peripheral drivers are: unique preconditions; continuous decisions impact; and extremes dichotomy. The study describes four moderators of the drivers: life cycle stage; stakeholder perspective; quantitative versus qualitative nature of signs and causes; and finally the age and size effects. Research limitations/implications: The proposed conceptual framework is based on literature only, although it has found support during discussions with practitioners. It is proposed to readers of this journal for scrutiny and validation. Practical implications: Strategists need to understand what drives decline in order to act timeously; practitioners who have an insight into the moderators with their impacts could make better decisions in response to decline in organisations and possibly avoid business failure. Originality/Value: Understanding business decline is still a huge theoretical challenge, which

  11. Management of moderate wind energy coastal resources

    International Nuclear Information System (INIS)

    Karamanis, D.

    2011-01-01

    Research highlights: → Life cycle analysis reveals the viability of moderate wind fields utilization. → Wind turbine is the greenest electricity generator at a touristic site. → Wind parks should be collective applications of small hotel-apartments owners. -- Abstract: The feasibility of wind energy utilization at moderate wind fields was investigated for a typical touristic coastal site in Western Greece. Initially, the wind speed and direction as well as its availability, duration and diurnal variation were assessed. For an analysis period of eight years, the mean wind speed at ten meters was determined as 3.8 m s -1 with a small variation in monthly average wind speeds between 3.0 (January) and 4.4 m s -1 (October). The mean wind power density was less than 200 W m -2 at 10 m indicating the limiting suitability of the site for the usual renewable energy applications. However, life cycle analysis for wind turbine generators with lower cut-in, cut-out, and rated speeds revealed that the energy yield ratio can reach a value of six for a service life of 20 years while the energy pay-back period can be 3 years with 33 kt CO 2 -e of avoided greenhouse emissions. Therefore, the recent technological turbine improvements make wind power viable even at moderate wind fields. Moreover, the study of electricity supply of typical small hotel-apartments in the region of Western Greece indicated that the installation of 300 wind turbine generators in these moderate wind fields would cover the total consumption during the open touristic period with profits during the rest of the year. According to these results, wind turbine generators are the 'greenest' way of generating electricity in touristic coastal sites, even of moderate wind speeds.

  12. Electric vehicles as flexible loads – A simulation approach using empirical mobility data

    International Nuclear Information System (INIS)

    Metz, Michael; Doetsch, Christian

    2012-01-01

    Due to the rapid increase of wind and photovoltaic generation, flexible storage applications become more important. Electric vehicles are supposed as one option to fill the gap between a fixed energy demand and a stochastic feed in from fluctuating energy sources. But the charging loads will also affect the grid load, since the transport sector contributes considerably to the total energy consumption today. This study examines the conflicting relationship between user mobility and grid support and introduces an approach to simulate large vehicle fleets on the basis of individual driving profiles. 9744 driving profiles from the German mobility panel were used within this examination. 958 were classified as potential early adopters for electric vehicles. Those vehicles could provide grid support in 81% of the time, when charging spots are available at home and at work. We simulated the charging loads under the restrictions of the individual mobility for the scenario 2030. Uncoordinated charging will increase the load fluctuations, whereas coordinated charging loads allow load shifting without limiting the mobility. The additional electricity demand is moderate over the next two decades. -- Highlights: ► We processed and analyzed 9744 driving profiles from a German mobility study. ► We simulated 3 concepts for a charging control, resulting in different load profiles. ► Additional energy demand of electric vehicles is moderate over the next two decades. ► Uncoordinated charging will increase the total peak load, coordinated charging can balance fluctuations.

  13. Loading Conditions and Longitudinal Strength

    DEFF Research Database (Denmark)

    Sørensen, Herman

    1995-01-01

    Methods for the calculation of the lightweight of the ship.Loading conditions satisfying draught, trim and intact stability requirements and analysis of the corresponding stillwater longitudinal strength.......Methods for the calculation of the lightweight of the ship.Loading conditions satisfying draught, trim and intact stability requirements and analysis of the corresponding stillwater longitudinal strength....

  14. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  15. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.

    1981-01-01

    A nuclear fuel loading apparatus, incorporating a microprocessor control unit, is described which automatically loads nuclear fuel pellets into dual fuel rods with a minimum of manual involvement and in a manner and sequence to ensure quality control and accuracy. (U.K.)

  16. Fatigue Reliability under Random Loads

    DEFF Research Database (Denmark)

    Talreja, R.

    1979-01-01

    We consider the problem of estimating the probability of survival (non-failure) and the probability of safe operation (strength greater than a limiting value) of structures subjected to random loads. These probabilities are formulated in terms of the probability distributions of the loads and the...... propagation stage. The consequences of this behaviour on the fatigue reliability are discussed....

  17. Quantifying the impact of moderate volcanic eruptions on the stratosphere

    Science.gov (United States)

    Lurton, Thibaut; Jégou, Fabrice; Berthet, Gwenaël; Renard, Jean-Baptiste; Vignelles, Damien; Bègue, Nelson; Portafaix, Thierry; Bencherif, Hassan; Couté, Benoît; Duverger, Vincent; Payen, Guillaume; Metzger, Jean-Marc; Posny, Françoise

    2016-04-01

    We have investigated the impact of two recent moderate volcanic eruptions upon the sulphur dioxide and sulphate loading in the stratosphere, with the use of the CESM numerical global model. Through the use of the WACCM/CARMA module in CESM, which provides with a comprehensive modelling of the sulphur cycle, and at a ˜2° spatial resolution, we have investigated the impacts of the eruptions of the Kelud (13 February 2014, 7° S, 112° E) and Calbuco (22 April 2015, 41° S, 72° W) volcanoes on the lower stratosphere. The input SO2 quantities and altitudes of injection were estimated from satellite observations, and correspond in both cases to several hundreds of kT of SO2 injected directly at upper troposphere/lower stratosphere heights, over a few kilometres of altitude span. Our results have been compared with satellite measurements, from IASI for SO2, and the CALIOP space-borne lidar for aerosols. We also provide cross-comparisons with in-situ measurements performed above La Réunion Island (21° S, 55° E), first comparing our simulation results to the data obtained through the launch of a balloon-borne light optical aerosol counter (LOAC), and also by cross-comparison with in-situ lidar measurements. To investigate the role of dynamical barriers around those volcanic events, our simulations have been run using two different sets of meteorological forcing data (namely MERRA vs. ERA-Interim), which can differ in that respect, especially regarding the vertical advection at tropical latitudes. Our overall aim is to assess the impact of such moderate eruptions over the lower stratosphere, on the one hand chemically, and on the other hand in terms of radiative effects.

  18. High moderation MOX cores for effective use of plutonium in LWRs

    International Nuclear Information System (INIS)

    Hamamoto, Kazuko; Kanagawa, Takashi; Hiraiwa, Koji; Sakurada, Koichi; Moriwaki, Masanao; Aoyama, Motoo; Yamamoto, Toru; Ueji, Masao

    2001-01-01

    Conceptual design studies have been performed for high moderation full MOX cores aiming at increasing fissile Pu consumption rate (ratio of the consumed to the loaded fissile Pu) and reducing residual Pu in discharged MOX fuel. The BWR cores studied have hydrogen to heavy metal ratio(H/HM) of 5.9 with increasing water rods and 7.0 with reducing a fuel rod diameter based on a reference 9x9 fuel (H/HM=4.9) of ABWR. The PWR cores studied have H/HM of 5.0 and 6.0 with reducing a fuel rod diameter based on a reference 17x17 fuel (H/HM=4.0) of APWR. Equilibrium core design and plant safety analyses showed that those high moderation cores have compatibility with ABWR and APWR. The fissile Pu consumption rate is 22% larger than the full MOX cores with reference fuel of ABWR and 50% for APWR. The core performance and compatibility has been also evaluated in the condition of multi-recycle of Pu in these high moderation cores. Study has been conducted to evaluate the effect of introducing these high moderation cores in the fuel cycle of Japan. It shows that the high moderation cores produce 26% more cumulative electricity and reduce 22% stock of the fissile Pu by 2050 than the reference cores. (author)

  19. Load forecasting of supermarket refrigeration

    DEFF Research Database (Denmark)

    Rasmussen, Lisa Buth; Bacher, Peder; Madsen, Henrik

    2016-01-01

    This paper presents a novel study of models for forecasting the electrical load for supermarket refrigeration. The data used for building the models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. Every hour the hourly electrical load for refrigeration is forecasted for the following 42 h. The forecast models are adaptive linear time series models. The model has two regimes; one for opening hours and one for closing hours, this is modeled by a regime switching model and two different...... methods for predicting the regimes are tested. The dynamic relation between the weather and the load is modeled by simple transfer functions and the non-linearities are described using spline functions. The results are thoroughly evaluated and it is shown that the spline functions are suitable...

  20. Multiobjective Economic Load Dispatch Problem Solved by New PSO

    Directory of Open Access Journals (Sweden)

    Nagendra Singh

    2015-01-01

    Full Text Available Proposed in this paper is a new particle swarm optimization technique for the solution of economic load dispatch as well as environmental emission of the thermal power plant with power balance and generation limit constraints. Economic load dispatch is an online problem to minimize the total generating cost of the thermal power plant and satisfy the equality and inequality constraints. Thermal power plants use fossil fuels for the generation of power; fossil fuel emits many toxic gases which pollute the environment. This paper not only considers the economic load dispatch problem to reduce the total generation cost of the thermal power plant but also deals with environmental emission minimization. In this paper, fuel cost and the environmental emission functions are considered and formulated as a multiobjective economic load dispatch problem. For obtaining the solution of multiobjective economic load dispatch problem a new PSO called moderate random search PSO was used. MRPSO enhances the ability of particles to explore in the search spaces more effectively and increases their convergence rates. The proposed algorithm is tested for the IEEE 30 bus test systems. The results obtained by MRPSO algorithm show that it is effective and efficient.

  1. Multilevel moderated mediation model with ordinal outcome.

    Science.gov (United States)

    Rusá, Šárka; Komárek, Arnošt; Lesaffre, Emmanuel; Bruyneel, Luk

    2018-05-10

    Although increasingly complex models have been proposed in mediation literature, there is no model nor software that incorporates the multiple possible generalizations of the simple mediation model jointly. We propose a flexible moderated mediation model allowing for (1) a hierarchical structure of clustered data, (2) more and possibly correlated mediators, and (3) an ordinal outcome. The motivating data set is obtained from a European study in nursing research. Patients' willingness to recommend their treating hospital was recorded in an ordinal way. The research question is whether such recommendation directly depends on system-level features in the organization of nursing care, or whether these associations are mediated by 2 measurements of nursing care left undone and possibly moderated by nurse education. We have developed a Bayesian approach and accompanying program that takes all the above generalizations into account. Copyright © 2018 John Wiley & Sons, Ltd.

  2. Moderation in Australia-Policy and Achievements

    OpenAIRE

    CREINA STOCKLEY

    2004-01-01

    Alcohol has been consumed in Australia since European settlement in 1788. In 1998, approximately 60 % of Australians consumed an alcoholic beverage at least once per week. The effects of alcohol on the human body are dose dependent, where the harmful effects of alcohol are generally observed only when alcohol consumption exceeds moderate consumption levels of 30 to 40 g of alcohol per day. The discovery that a J-shaped curve described the relationship between level of alcohol consumption and ...

  3. Moderate alcohol consumption and chronic disease

    DEFF Research Database (Denmark)

    Mukamal, Kenneth J; Clowry, Catherine M; Murray, Margaret M

    2016-01-01

    Drinking within recommended limits is highly prevalent in much of the world, and strong epidemiological associations exist between moderate alcohol consumption and risk of several major chronic diseases, including coronary heart disease, diabetes, and breast cancer. In many cases, plausible...... the observed associations have been termed impossible, clinical investigators have now successfully completed randomized trials of complex nutritional interventions in a variety of settings, along with trials of alcohol consumption itself of up to 2 years duration. The successful completion of these trials...

  4. Quasi-monolithic silicon load cell for loads up to 1000 kg with insensitivity to non-homogeneous load distributions

    NARCIS (Netherlands)

    Wiegerink, Remco J.; Zwijze, A.F.; Krijnen, Gijsbertus J.M.; Lammerink, Theodorus S.J.; Elwenspoek, Michael Curt

    In this paper, a micromachined silicon load cell (force sensor) is presented for measuring loads up to 1000 kg. The sensitive surface of 1 cm2 contains a matrix of capacitive sensing elements to make the load cell insensitive to non-homogeneous load distributions. The load cell has been realized and

  5. Graphite-moderated and heavy water-moderated spectral shift controlled reactors

    International Nuclear Information System (INIS)

    Alcala Ruiz, F.

    1984-01-01

    It has been studied the physical mechanisms related with the spectral shift control method and their general positive effects on economical and non-proliferant aspects (extension of the fuel cycle length and low proliferation index). This methods has been extended to non-hydrogenous fuel cells of high moderator/fuel ratio: heavy water cells have been con- trolled by graphite rods graphite-moderated and gas-cooled cells have been controlled by berylium rods and graphite-moderated and water-cooled cells have been controlled by a changing mixture of heavy and light water. It has been carried out neutron and thermal analysis on a pre design of these types of fuel cells. We have studied its neutron optimization and their fuel cycles, temperature coefficients and proliferation indices. Finally, we have carried out a comparative analysis of the fuel cycles of conventionally controlled PWRs and graphite-moderated, water-cooled and spectral shift controlled reactors. (Author) 71 refs

  6. Sns Moderator Poison Design and Experiment Validation of the Moderator Performance

    Science.gov (United States)

    Lu, W.; Iverson, E. B.; Ferguson, P. D.; Crabtree, J. A.; Gallmeier, F. X.; Remec, I.; Baxter, D. V.; Lavelle, C. M.

    2009-08-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached 180 kW in August 2007, becoming the brightest pulsed neutron source in the world. At its full power of 1.4 MW, SNS will have thermal neutron fluxes approximately an order of magnitude greater than any existing pulsed spallation source. It thus brings a serious challenge to the lifetime of the moderator poison sheets. The SNS moderators are integrated with the inner reflector plug (IRP) at a cost of $2 million a piece. A replacement of the IRP presents a significant drawback to the facility due to the activation and the operation cost. Although there are many factors limiting the lifetime of the IRP, such as radiation damage to the structural material and helium production in beryllium, the limiting factor is the lifetime of the moderator poison sheets. The current operating target system of SNS was built with thick Gd poison sheets at a projected lifetime of 3 years. A recent design based on the MCNPX calculation proposed to replace the Gd poison sheets with even thicker Cd poison sheets, aiming to extend the poison sheet lifetime from 3 to 4 years accompanied by an approximate 5% gain of the moderator performance. An experiment was carried out to verify the calculated moderator performance at the Low Energy Neutron Source (LENS), Indiana University, where the spectra of two polyethylene moderators were measured. The moderators are Cd-decoupled and are poisoned with 0.8 mm Gd and 1.2 mm Cd, respectively. The preliminary analysis of the experiment data shows that the characteristics of the measured spectra of the Gd- and Cd-poisoned moderators agree well with what the calculation predicted. A better moderator performance is observed in the Cd-poisoned moderator. The measured ratio of Cd over Gd on the moderator performance is in a reasonable agreement with the calculation. Further investigation is underway for a better understanding of the difference between the experiment and the

  7. Seasonal Training Load and Wellness Monitoring in a Professional Soccer Goalkeeper.

    Science.gov (United States)

    Malone, James J; Jaspers, Arne; Helsen, Werner F; Merks, Brenda; Frencken, Wouter Gp; Brink, Michel S

    2017-11-28

    The purpose of this investigation was to: (a) quantify the training load practices of a professional soccer GK, and (b) investigate the relationship between the training load observed and the subsequent self-reported wellness response. One male goalkeeper playing for a team in the top league of the Netherlands participated in this case study. Training load data were collected across a full season using a global positioning system (GPS) device and session rating of perceived exertion (session-RPE). Data was assessed in relation to the number of days to a match (MD- and MD+). In addition, self-reported wellness was assessed using a questionnaire. Duration, total distance, average speed, PlayerLoad TM and load (derived from session-RPE) were highest on MD. The lowest values for duration, total distance and PlayerLoad TM were observed on MD-1 and MD+1. Total wellness scores were highest on MD and MD-3 and were lowest on MD+1 and MD-4. Small to moderate correlations between training load measures (duration, total distance covered, high deceleration efforts and load) and the self-reported wellness scores were found. This exploratory case-study provides novel data about the physical load undertaken by a goalkeeper during one competitive season. The data suggest there are small to moderate relationships between training load indicators and self-reported wellness. This weak relation indicates that the association is not meaningful. This may be due to the lack of position-specific training load parameters we can currently measure in the applied context.

  8. The Atlas load protection switch

    CERN Document Server

    Davis, H A; Dorr, G; Martínez, M; Gribble, R F; Nielsen, K E; Pierce, D; Parsons, W M

    1999-01-01

    Atlas is a high-energy pulsed-power facility under development to study materials properties and hydrodynamics experiments under extreme conditions. Atlas will implode heavy liner loads (m~45 gm) with a peak current of 27-32 MA delivered in 4 mu s, and is energized by 96, 240 kV Marx generators storing a total of 23 MJ. A key design requirement for Atlas is obtaining useful data for 95601130f all loads installed on the machine. Materials response calculations show current from a prefire can damage the load requiring expensive and time consuming replacement. Therefore, we have incorporated a set of fast-acting mechanical switches in the Atlas design to reduce the probability of a prefire damaging the load. These switches, referred to as the load protection switches, short the load through a very low inductance path during system charge. Once the capacitors have reached full charge, the switches open on a time scale short compared to the bank charge time, allowing current to flow to the load when the trigger pu...

  9. Hemodynamic responses to mental stress during salt loading

    DEFF Research Database (Denmark)

    Goyal, Maria Gefke; Christensen, Niels Juel; Bech, Per

    2017-01-01

    PURPOSE: The purpose was to examine whether prolonged moderate stress associated with a student exam would increase the blood pressure response to a salt load in young healthy normotensive individuals. METHODS: Ten healthy young subjects were examined at two different occasions in random order (i...... in day-to-night systolic blood pressure during high-salt intake and moderate stress may indicate that stress affects blood pressure regulation.......PURPOSE: The purpose was to examine whether prolonged moderate stress associated with a student exam would increase the blood pressure response to a salt load in young healthy normotensive individuals. METHODS: Ten healthy young subjects were examined at two different occasions in random order (i......) during preparation for a medical exam (prolonged stress) and (ii) outside the exam period (low stress). All subjects consumed a controlled diet for 3 days with low- or high-salt content in randomized order. The subjective stress was measured by Spielberger's State-Trait Anxiety Inventory-Scale, SCL...

  10. Probability Based Ship Design; Loads and Load Combinations

    Science.gov (United States)

    1993-11-01

    Ferry Borges, J. and Castenhata, M., "Structural Safety," Second Edition, Laboratario Nacional de Engenharia Civil , Lisbon, 1972. 3.18. Wen, Y.K...probability-based fatigue design, Thayamballi on fatigue load assessments, Munse on fatigue criteria, Wen on civil engineering load combinations, Mansour on...1.17. Ferry Borges, J. and Castenhata, M., "Structural Safety," Laboratoria Nacional de Engenhera Civil , Lisbon, 1971. 1.18. Engle, A. Private

  11. Optimization of moderators and beam extraction at the ESS

    Czech Academy of Sciences Publication Activity Database

    Andersen, K. H.; Bertelsen, M.; Zanini, L.; Klinkby, E. B.; Schonfeldt, T.; Bentley, P. M.; Šaroun, Jan

    2018-01-01

    Roč. 51, č. 4 (2018), s. 264-281 ISSN 1600-5767 R&D Projects: GA MŠk LM2015048 Institutional support: RVO:61389005 Keywords : water moderators * para-hydrogen moderators * low-dimensional moderators * pancake moderators * butterfly moderators * brilliance transfer * neutron instruments Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.495, year: 2016

  12. Effectiveness of Moderate Intensity Interval Training as an Index of Autonomic Nervous Activity.

    Science.gov (United States)

    Kai, Satoru; Nagino, Koji; Ito, Takayoshi; Oi, Rie; Nishimura, Kazushi; Morita, Shuhei; Yaoi, Riyo

    2016-01-01

    The purpose of this study was to examine the effects of moderate intensity interval training from the change of the autonomic nervous activity. Ten male volunteers aged 21-22 years were studied. After 10-minute rest in a seated position, the subjects were asked to perform the strength of moderate cycling exercise in ergometer. Cycling rate was done in 50 times/min. Load resistance of the ergometer was set to 2.0 kgm. Subjects paused the exercise when the heart rate becomes 120 beats/min. Subjects have resumed the exercise when the heart rate returns to the value at rest. This trial was repeated twice. The experiment was ended when the heart rate of the subjects has returned to resting level. When the heart rate during exercise is maintained to less than 120 beats/min, sympathetic nerve activity during exercise did not work actively compared to the baseline. Vagus nerve activity after exercise cessation exceeds the baseline. It is clarified that the exercise as well as activating the vagus nerve activity stimulates the total autonomic nervous activity. It has revealed that at the time of interval training at moderate load the vagus nerve activity can be carried out.

  13. Effectiveness of Moderate Intensity Interval Training as an Index of Autonomic Nervous Activity

    Directory of Open Access Journals (Sweden)

    Satoru Kai

    2016-01-01

    Full Text Available The purpose of this study was to examine the effects of moderate intensity interval training from the change of the autonomic nervous activity. Ten male volunteers aged 21-22 years were studied. After 10-minute rest in a seated position, the subjects were asked to perform the strength of moderate cycling exercise in ergometer. Cycling rate was done in 50 times/min. Load resistance of the ergometer was set to 2.0 kgm. Subjects paused the exercise when the heart rate becomes 120 beats/min. Subjects have resumed the exercise when the heart rate returns to the value at rest. This trial was repeated twice. The experiment was ended when the heart rate of the subjects has returned to resting level. When the heart rate during exercise is maintained to less than 120 beats/min, sympathetic nerve activity during exercise did not work actively compared to the baseline. Vagus nerve activity after exercise cessation exceeds the baseline. It is clarified that the exercise as well as activating the vagus nerve activity stimulates the total autonomic nervous activity. It has revealed that at the time of interval training at moderate load the vagus nerve activity can be carried out.

  14. Effect of burnup history by moderator density on neutron-physical characteristics of WWER-1000 core

    International Nuclear Information System (INIS)

    Ovdiienko, I.; Kuchin, A.; Khalimonchuk, V.; Ieremenko, M.

    2011-01-01

    Results of assessment of burnup history effect by moderator density on neutron physical characteristics of WWER-1000 core are presented on example of stationary fuel loading with Russian design fuel assembly TWSA and AER benchmark for Khmelnitsky NPP that was proposed by TUV and SSTC NRC at nineteenth symposium. Assessment was performed by DYN3D code and cross section library sets generated by HELIOS code. Burnup history was taken into account by preparing of numerous cross section sets with different isotopic composition each of which was obtained by burning under different moderator density. For analysis of history effect 20 cross section sets were prepared for each fuel assembly corresponded to each of 20 axial layers of reactor core model for DYN3D code. Four fuel cycles were modeled both for stationary fuel loading with TWSA and AER benchmark for Khmelnitsky NPP to obtain steady value of error due to neglect of burnup history effect. Main attention of study was paid to effect of burnup history by moderator density to axial power distribution. Results of study for AER benchmark were compared with experimental values of axial power distribution for fuel assemblies of first, second, third and fourth year operation. (Authors)

  15. Overview of strength, crack propagation and fracture of nuclear reactor moderator graphite

    International Nuclear Information System (INIS)

    Moskovic, R.; Heard, P.J.; Flewitt, P.E.J.; Wootton, M.R.

    2013-01-01

    Highlights: • Fracture behaviour. • Cracking initiation and growth. • Different loadings configurations. • Fracture mechanisms. -- Abstract: Nuclear reactor moderator graphite is an aggregate of needle coke filler particles within a matrix of fine coke flour particles mixed with pitch binder. Following extrusion in green condition, impregnation with liquid pitch binder and graphitisation, a polygranular aggregate with orthotropic properties is produced. Its mechanical properties under several different loading conditions and associated cracking behaviour were examined to establish crack initiation and propagation behaviour. Both virgin and radiolytically oxidised material were examined using optical and electron optical microscopy, focused ion beam microscope and digital image correlation. The appearance of force vs. displacement curves varied with type of loading. Mostly linear elastic traces occurred in uniaxial tensile and flexural tests. Large departures from linear elastic behaviour were observed in standard uniaxial and diametral compression testing. Digital image correlation has shown that the initiation of cracking involves formation of a process zone which grows to a critical size of approximately 3–5 mm before a macro-crack is initiated. Cracks straddle a torturous path which zigzags between the filler particles through the matrix consistent with crack propagation along the filler matrix interface. This paper provides an overview of strength, crack propagation and fracture of nuclear reactor moderator graphite. It reviews the physical processes and mathematical approaches that have been adopted to describe the behaviour of brittle materials and then considers if they apply to reactor core graphites

  16. Therapy of moderate and severe psoriasis

    Directory of Open Access Journals (Sweden)

    Werfel, Thomas

    2006-04-01

    Full Text Available Objective and methods: This health technology assessment (HTA report synthesises systematically randomized controlled studies (RCT on the therapy of moderate and severe psoriasis vulgaris which were published between 1999 and 2004; it includes some important clinical studies which have been published after 2004 and thus updates the English HTA report by Griffiths et al. [1]. The major objective is the evaluation of the medical effectiveness of different therapeutical approaches and the cost effectiveness with relevance for Germany. Results: The major conclusions from the results of medical RCT on moderate and severe psoriasis vulgaris are: Oral fumarates are effective in the treatment of moderate to severe psoriasis vulgaris. However, fumarates quiet frequently cause moderate side effects. Cyclosporine and methotrexate are both effective in the treatment of severe psoriasis vulgaris. Both substances have a different spectrum of side effects which may limit the individual applicability. Acetritin is only moderately effective in the treatment of severe psoriasis of the plaque type. Calcipotriol or UV-radiation used at the same time can increase the clinical effectiveness of acetritin. Systemic PUVA, balneo-PUVA and UVB therapy are all effective for the treatment of severe psoriasis. The combination of UV therapy with vitamin D3 analogues or with topical steroids is more effective than the treatment with UV radiation alone. Saltwater baths increase the effectiveness of UVB therapy. No RCT on the therapeutical effects of topical tar or of dithranol in combination with UV therapy have been published so far. A continuous therapy with PUVA should not be applied due to its proven photocarcinogenicity. Three substances from the group of biologicals (Efalizumab, Etanercept, and Infliximab are now available in Europe and a further substance (Alefacept is available in the USA for the treatment of moderate to severe psoriasis. All biologicals have been

  17. Therapy of moderate and severe psoriasis.

    Science.gov (United States)

    Claes, Christa; Kulp, Werner; Greiner, Wolfgang; von der Schulenburg, Johann-Matthias; Werfel, Thomas

    2006-04-26

    This health technology assessment (HTA) report synthesises systematically randomized controlled studies (RCT) on the therapy of moderate and severe psoriasis vulgaris which were published between 1999 and 2004; it includes some important clinical studies which have been published after 2004 and thus updates the English HTA report by Griffiths et al. [1]. The major objective is the evaluation of the medical effectiveness of different therapeutical approaches and the cost effectiveness with relevance for Germany. The major conclusions from the results of medical RCT on moderate and severe psoriasis vulgaris are: Oral fumarates are effective in the treatment of moderate to severe psoriasis vulgaris. However, fumarates quiet frequently cause moderate side effects. Cyclosporine and methotrexate are both effective in the treatment of severe psoriasis vulgaris. Both substances have a different spectrum of side effects which may limit the individual applicability. Acetritin is only moderately effective in the treatment of severe psoriasis of the plaque type. Calcipotriol or UV-radiation used at the same time can increase the clinical effectiveness of acetritin. Systemic PUVA, balneo-PUVA and UVB therapy are all effective for the treatment of severe psoriasis. The combination of UV therapy with vitamin D3 analogues or with topical steroids is more effective than the treatment with UV radiation alone. Saltwater baths increase the effectiveness of UVB therapy. No RCT on the therapeutical effects of topical tar or of dithranol in combination with UV therapy have been published so far. A continuous therapy with PUVA should not be applied due to its proven photocarcinogenicity. Three substances from the group of biologicals (Efalizumab, Etanercept, and Infliximab) are now available in Europe and a further substance (Alefacept) is available in the USA for the treatment of moderate to severe psoriasis. All biologicals have been effective in placebo controlled studies. The

  18. Improving bridge load rating accuracy.

    Science.gov (United States)

    2013-06-01

    Nearly one-quarter of Alabamas bridges are deemed structurally deficient or functionally obsolete. An : additional seven percent of Alabamas bridges were posted bridges in 2010. (Federal Highway Administration, : 2011) Accurate bridge load rati...

  19. Nuclear fuel pellet loading machine

    International Nuclear Information System (INIS)

    Kee, R.W.; Denero, J.V.

    1975-01-01

    An apparatus for loading nuclear fuel pellets on trays for transfer in a system is described. A conveyor supplies pellets from a source to a loading station. When the pellets reach a predetermined position at the loading station, a manual or automatically operated arm pushes the pellets into slots on a tray and this process is repeated until pellet sensing switches detect that the tray is full. Thereupon, the tray is lowered onto a belt or other type conveyor and transferred to other apparatus in the system, such as a furnace for sintering, and in some cases, reduction of UO 2 . 2 to UO 2 . The pellets are retained on the tray and subsequently loaded directly into fuel rods to be used in the reactor core. (auth)

  20. Numerical prediction of slamming loads

    DEFF Research Database (Denmark)

    Seng, Sopheak; Jensen, Jørgen J; Pedersen, Preben T

    2012-01-01

    It is important to include the contribution of the slamming-induced response in the structural design of large vessels with a significant bow flare. At the same time it is a challenge to develop rational tools to determine the slamming-induced loads and the prediction of their occurrence. Today...... it is normal practice to apply a standard sea-keeping procedure to determine the relative velocity distribution between the water surface and the hull and then to estimate the bottom slamming loads and the bow-flare slamming loads based on two-dimensional formulations similarly to water-entry problems....... The pressure distribution as well as the total force is then determined by integration over a pseudo-three-dimensional presentation of the hull geometry.In this paper the evaluation of the slamming load is taken one step further by performing direct three-dimensional, fully non-linear numerical calculations...

  1. Plutonium Immobilization Can Loading Concepts

    International Nuclear Information System (INIS)

    Kriikku, E.; Ward, C.; Stokes, M.; Randall, B.; Steed, J.; Jones, R.; Hamilton, L.; Rogers, L.; Fiscus, J.; Dyches, G.

    1998-05-01

    The Plutonium Immobilization Facility will encapsulate plutonium in ceramic pucks and seal the pucks inside welded cans. Remote equipment will place these cans in magazines and the magazines in a Defense Waste Processing Facility (DWPF) canister. The DWPF will fill the canister with glass for permanent storage. This report discusses five can loading conceptual designs and the lists the advantages and disadvantages for each concept. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas. The can loading welder and cutter are very similar to the existing Savannah River Site (SRS) FB-Line bagless transfer welder and cutter and thus they are a low priority development item

  2. Structural Impact of Construction Loads

    Science.gov (United States)

    2012-08-01

    Numerous bridge construction accidents have occurred across the country because of construction loadings, which are an underemphasized : topic in many DOT specifications and design manuals. Bridge girders are least stable when they are subjected to c...

  3. Aircraft ditching loads simulation tool

    OpenAIRE

    Bonanni, A.; Vandewaeter, L.; Havill, C.; Kanyoo, P.; Taunton, D.J.; Blake, J.I.R.; Cropper, E.; Hancock, S.

    2015-01-01

    The present work presents a novel methodology developed for calculating the steady loads acting on aircraft structures in the event of ditching in water. It represents the preliminary result of Stirling Dynamics as part of a NATEP research project. The overall objective of the project is to expand the capabilities of the Stirling Dynamics proprietary software SD-GLOAD (originally designed for ground and crash loads dynamic simulations) to aircraft ditching simulations. The methodology present...

  4. Wind Structure and Wind Loading

    DEFF Research Database (Denmark)

    Brorsen, Michael

    The purpose of this note is to provide a short description of wind, i.e. of the flow in the atmosphere of the Earth and the loading caused by wind on structures. The description comprises: causes to the generation of windhe interaction between wind and the surface of the Earthhe stochastic nature...... of windhe interaction between wind and structures, where it is shown that wind loading depends strongly on this interaction...

  5. Fuel rod pellet loading head

    International Nuclear Information System (INIS)

    Howell, T.E.

    1975-01-01

    An assembly for loading nuclear fuel pellets into a fuel rod comprising a loading head for feeding pellets into the open end of the rod is described. The pellets rest in a perforated substantially V-shaped seat through which air may be drawn for removal of chips and dust. The rod is held in place in an adjustable notched locator which permits alignment with the pellets

  6. On the behaviour characterization of metallic cellular materials under impact loading

    Science.gov (United States)

    Fang, Dai-Ning; Li, Yu-Long; Zhao, Han

    2010-12-01

    This paper reviews the common mechanical features of the metallic cellular material under impact loading as well as the characterization methods of such behaviours. The main focus is on the innovations of various testing methods at impact loading rates. Following aspects were discussed in details. (1) The use of soft nylon Hopkinson/Kolsky bar for an enhanced measuring accuracy in order to assess if there is a strength enhancement or not for this class of cellular materials under moderate impact loading; (2) The use of digital image correlations to determine the strain fields during the tests to confirm the existence of a pseudo-shock wave propagation inside the cellular material under high speed impact; (3) The use of new combined shear compression device to determine the loading envelop of cellular materials under impact multiaxial loadings.

  7. Comparison of coupled and uncoupled load simulations on a jacket support structure

    DEFF Research Database (Denmark)

    Haselbach, Philipp Ulrich; Natarajan, Anand; Jiwinangun, Randi Gusto

    2013-01-01

    In this article, a comparison of the moments and forces at the joints of a jacket structure is made between fully coupled aerohydroelastic simulations in HAWC2 and uncoupled load predictions in the finite element software Abaqus. The jacket sub structure is modelled in moderate deep waters of 50m...... structure similar to the Upwind reference jacket is developed in the Abaqus environment, to which is added the transition piece and tower. The aeroelastic loads determined in normal operating conditions of the turbine is integrated and centralized as nodal forces and moments acting at the tower top...... in Abaqus. The fully coupled simulation is implemented and performed in HAWC2. In the uncoupled case, the loads (wave loads and tower base loads) are analysed by an implicit structural Finite Element Analysis (Abaqus 6.11-1). A subroutine is used as a preprocessor generating a beam element model and linking...

  8. Three-dimensional flow and load characteristics of flexible revolving wings at low Reynolds number

    NARCIS (Netherlands)

    van de Meerendonk, R.; Perçin, M.; van Oudheusden, B.W.

    2016-01-01

    This study explores the flow field and fluid-dynamic loads generated by revolving low-aspect-ratio flat plate wings undergoing a revolving motion starting from rest. Three wings with different degree of chordwise flexural stiffness (i.e., rigid, moderate flexibility and high flexibility) have been

  9. Cavitary Disease and Quantitative Sputum Bacillary Load in Cases of Pulmonary Tuberculosis▿

    OpenAIRE

    Palaci, Moises; Dietze, Reynaldo; Hadad, David Jamil; Ribeiro, Fabiola Karla Corrêa; Peres, Renata Lyrio; Vinhas, Solange Alves; Maciel, Ethel Leonor Noia; do Valle Dettoni, Valdério; Horter, Libby; Boom, W. Henry; Johnson, John L.; Eisenach, Kathleen D.

    2007-01-01

    We examined sputum bacterial loads in adults with newly diagnosed tuberculosis using quantitative culture and time-until-positive (DTP) culture in BACTEC 460. Patients with cavitary disease had higher CFU levels than those without cavities and shorter DTPs. Within radiographic strata of moderately and far advanced tuberculosis, higher CFU counts were associated with cavitary disease.

  10. Environmental Aspects of Load Management

    International Nuclear Information System (INIS)

    Abaravicius, Juozas

    2004-02-01

    This study approaches load management from an environmental perspective. It identifies and discusses the possible environmental benefits of load management and evaluates their significance, primary focusing on CO 2 emissions reduction. The analysis is carried out on two levels: national - the Swedish electricity market, and local - one electric utility in southern Sweden. Our results show the importance of considering the influence of site-specific or level-specific conditions on the environmental effects of load management. On the national level, load management measures can hardly provide significant environmental benefits, due to the high hydropower production in Sweden, which is the demand following production source. Emission reductions will rather be the result of energy efficiency measures, which will cut the load demand as well as the energy demand. However, when it comes to a local (utility) level, where load management is considered as an alternative to an installation of peak diesel power plant, the benefits are clear. It is demonstrated that significant CO 2 emissions savings can be achieved due to avoided peak diesel power production

  11. Drug Loading of Mesoporous Silicon

    Science.gov (United States)

    Moffitt, Anne; Coffer, Jeff; Wang, Mengjia

    2011-03-01

    The nanostructuring of crystalline solids with low aqueous solubilities by their incorporation into mesoporous host materials is one route to improve the bioavailability of such solids. Earlier studies suggest that mesoporous Si (PSi), with pore widths in the range of 5-50 nm, is a candidate for such an approach. In this presentation, we describe efforts to load curcumin into free-standing microparticles of PSi. Curcumin is a compound extracted from turmeric root, which is an ingredient of curry. Curucmin has shown activity against selected cancer cell lines, bacteria, and other medical conditions. However, curcumin has a very low bioavailability due to its extremely low water solubility (0.6 μ g/mL). Incorporation of curcumin was achieved by straightforward loading of the molten solid at 185circ; C. Loading experiments were performed using PSi particles of two different size ranges, 45-75 μ m and 150-250 μ m. Longer loading times and ratio of curcumin to PSi leads to a higher percentage of loaded curcumin in both PSi particle sizes (as determined by weight difference). The extent of curcumin crystallinity was assessed by x-ray diffraction (XRD). The solubility and release kinetics of loaded curcumin from the PSi was determined by extraction into water at 37circ; C, with analysis using UV-VIS spectrometry. NSF-REU and TCU.

  12. Developing food supplements for moderately malnourished children

    DEFF Research Database (Denmark)

    Briend, André; Akomo, Peter; Bahwere, Paluku

    2015-01-01

    Ready-to-use therapeutic foods (RUTFs) are solid foods that were developed by changing the formulation of the existing liquid diet, F-100, recommended by the World Health Organization (WHO) for the rapid catch-up phase of the treatment of children suffering from severe acute malnutrition (SAM......). The resulting products proved highly effective in promoting weight gain in both severely and moderately wasted children and adults, including those infected with HIV. The formulation of the existing RUTFs, however, has never been optimized to maximize linear growth, vitamin and mineral status, and functional...

  13. Cardiopulmonary Changes with Moderate Decompression in Rats

    Science.gov (United States)

    Robinson, R.; Little, T.; Doursout, M.-F.; Butler, B. D.; Chelly, J. E.

    1996-01-01

    Sprague-Dawley rats were compressed to 616 kPa for 120 min then decompressed at 38 kPa/min to assess the cardiovascular and pulmonary responses to moderate decompression stress. In one series of experiments the rats were chronically instrumented with Doppler ultrasonic probes for simultaneous measurement of blood pressure, cardiac output, heart rate, left and right ventricular wall thickening fraction, and venous bubble detection. Data were collected at base-line, throughout the compression/decompression protocol, and for 120 min post decompression. In a second series of experiments the pulmonary responses to the decompression protocol were evaluated in non-instrumented rats. Analyses included blood gases, pleural and bronchoalveolar lavage (BAL) protein and hemoglobin concentration, pulmonary edema, BAL and lung tissue phospholipids, lung compliance, and cell counts. Venous bubbles were directly observed in 90% of the rats where immediate post-decompression autopsy was performed and in 37% using implanted Doppler monitors. Cardiac output, stroke volume, and right ventricular wall thickening fractions were significantly decreased post decompression, whereas systemic vascular resistance was increased suggesting a decrease in venous return. BAL Hb and total protein levels were increased 0 and 60 min post decompression, pleural and plasma levels were unchanged. BAL white blood cells and neutrophil percentages were increased 0 and 60 min post decompression and pulmonary edema was detected. Venous bubbles produced with moderate decompression profiles give detectable cardiovascular and pulmonary responses in the rat.

  14. Moderation in Australia-Policy and Achievements

    Directory of Open Access Journals (Sweden)

    CREINA STOCKLEY

    2004-01-01

    Full Text Available Alcohol has been consumed in Australia since European settlement in 1788. In 1998, approximately 60 % of Australians consumed an alcoholic beverage at least once per week. The effects of alcohol on the human body are dose dependent, where the harmful effects of alcohol are generally observed only when alcohol consumption exceeds moderate consumption levels of 30 to 40 g of alcohol per day. The discovery that a J-shaped curve described the relationship between level of alcohol consumption and risk of cardiovascular disease was, however, only made in 1990_cardiovascular disease is the leading cause of death in the western world. Thus prior to 1990, Australian public health policy focused primarily on the harmful effects of alcohol consumption and the health benefits of a moderate level of alcohol consumption have only recently been recognized in public policy. This paper chronicles changes in Australian Federal government policy on alcohol since the initial draft National health policy on alcohol in Australia was presented to the Ministerial Council on Drug Strategy in 1987 to the National Drug Strategic plan for action 2001 to 2003-2004 which was launched in July last year

  15. Antecedents and Moderators of Software Professionals’ Performance

    Directory of Open Access Journals (Sweden)

    Shiva Prasad H. C.

    2014-02-01

    Full Text Available Software professionals’ (SPs' performance is often understood narrowly in terms of input–output productivity. This study approaches performance from a broader perspective and examines whether the emotional intelligence competencies (EICs of SPs, the leadership style of team leaders, social capital among team members, and human resource management (HRM practices of software firms affect performance of SPs. It also tests whether the value of and opportunities for knowledge sharing moderate such relationships. Data were collected from 441 Indian SPs in a questionnaire survey. Fifty-five team leaders assessed the performance of SPs, and SPs assessed the other constructs. Results revealed that EICs, transformational leadership style, social capital, and HRM practices positively affect performance. EICs are the most important predictors of performance. Under high (low value of and high (low opportunities for knowledge sharing, the antecedents influencing performance are strengthened (attenuated or nullified. The value of and opportunities for knowledge sharing are quasi-moderators. These findings have significant implications for organizing effective work teams.

  16. Neutron moderation at very low temperatures (1691)

    International Nuclear Information System (INIS)

    Lacaze, A.

    1961-04-01

    Starting from Harwell experiment carried out inside a low-power reactor, we intended to maintain a liquid hydrogen cell in a channel of the EL3 reactor (at Saclay) whose thermal neutrons flux is 10 14 neutrons/cm 2 /s. We tried to work out a device giving off an important beam of cold neutrons and able to operate in a way as automatic as possible during many consecutive day without a stop. Several circuits have already been achieved at very low temperatures but they brought out volumes and fluxes much lower than those we used this time. The difficulties we have met in carrying out such a device arose on the one hand from the very high energy release to which any kind of experiment is inevitably submitted when placed near the core of the reactor, on the other, hand from the very little room which is available in experimental channels of reactors. In such condition, it is necessary to use a moderator as effective as possible. This study is divided into three parts ; in the first part, we try to determine: a) conditions in which moderation takes place, hence the volume of the cell; b) materials likely to be used at low temperature and in pile; c) cooling system; hence we had to study fluid flow conditions at very low temperatures in very long ducts. The second part is devoted to the description of the device. The third part ventilates the results we have obtained. (author) [fr

  17. Moderating diets to feed the future

    Science.gov (United States)

    Davis, Kyle F.; D'Odorico, Paolo; Rulli, Maria Cristina

    2014-10-01

    Population growth, dietary changes, and increasing biofuel use are placing unprecedented pressure on the global food system. While this demand likely cannot be met by expanding agricultural lands, much of the world's cropland can attain higher crop yields. Therefore, it is important to examine whether increasing crop productivity to the maximum attainable yield (i.e., yield gap closure) alone can substantially improve food security at global and national scales. Here we show that closing yield gaps through conventional technological development (i.e., fertilizers and irrigation) can potentially meet future global demand if diets are moderated and crop-based biofuel production is limited. In particular, we find that increases in dietary demand will be largely to blame should crop production fall short of demand. In converting projected diets to a globally adequate diet (3000 kcal/cap/d; 20% animal kcal) under current agrofuel use, we find that 1.8-2.6 billion additional people can be fed in 2030 and 2.1-3.1 billion additional people in 2050, depending on the extent to which yields can improve in those periods. Therefore, the simple combination of yield gap closure and moderating diets offers promise for feeding the world's population but only if long-term sustainability is the focus.

  18. Moderate biomanipulation for eutrophication control in reservoirs using fish captured in angling competitions

    Directory of Open Access Journals (Sweden)

    Amaral S.D.

    2015-01-01

    Full Text Available Angling competitions are a popular leisure activity in reservoirs of Southern Portugal. These competitions can gather more than 100 anglers aiming to catch the maximum fish weight. Groundbaiting and catch-and-release angling are two common practices for anglers in competition. In this study, the loads of nutrients from commercial groundbait powders used in angling competitions in the Maranhão reservoir and the possible balance out of those nutrients through a moderate biomanipulation of the fish biomass caught in competitions were analysed. In order to achieve this aim, chemical analyses to groundbait powders most purchased by Portuguese anglers and to fish species most captured in competitions were made. Mass balances on inputs and outputs of nutrients considering some biomanipulation scenarios were evaluated. Results demonstrated that an effective management on angling competitions implementing a moderate biomanipulation of fish in reservoirs could promote the control of fish fauna and eutrophication, balancing out nutrients from angling.

  19. Lower limb mechanics during moderate high-heel jogging and running in different experienced wearers.

    Science.gov (United States)

    Fu, Fengqin; Zhang, Yan; Shu, Yang; Ruan, Guoqing; Sun, Jianjun; Baker, Julien S; Gu, Yaodong

    2016-08-01

    The aim of this study is to investigate the differences in lower limb kinematics and kinetics between experienced (EW) and inexperienced (IEW) moderate high-heel wearers during jogging and running. Eleven experienced female wearers of moderate high-heel shoes and eleven matched controls participated in jogging and running tests. A Vicon motion analysis system was used to capture kinematic data and a Kistler force platform was used to collect ground reaction force (GRF). There were no significant differences in jogging and running speed respectively. Compared with IEW, EW adopted larger stride length (SL) with lower stride frequency (SF) at each corresponding speed. During running, EW enlarged SL significantly while IEW increased both SL and SF significantly. Kinematic data showed that IEW had generally larger joint range of motion (ROM) and peak angles during stance phase. Speed effect was not obvious within IEW. EW exhibited a significantly increased maximal vertical GRF (Fz2) and vertical average loading rate (VALR) during running, which was potentially caused by overlong stride. These suggest that both EW and IEW are at high risk of joint injuries when running on moderate high heels. For wearers who have to do some running on moderate high heels, it is crucial to control joint stability and balance SL and SF consciously. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Modulation Methods for Three-level Neutral-Point-Clamped Inverter Achieving Stress Redistribution under Moderate Modulation Index

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2016-01-01

    This letter investigates the loss and thermal behaviors of a three-level neutral-point-clamped (3L-NPC) inverter undergoing moderate modulation index, which is typically presented during minor voltage sags of the power grid or speed changes of the electric machines. A series of new space vector...... modulation methods is then proposed to relocate the thermal loading among the power devices. It is concluded that, with some of the proposed modulation methods, the device loading in the 3L-NPC inverter can be effectively modified and optimized, and the junction temperature of the most stressed devices can...

  1. Analysis of moderately thin-walled beam cross-sections by cubic isoparametric elements

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2014-01-01

    In technical beam theory the six equilibrium states associated with homogeneous tension, bending, shear and torsion are treated as individual load cases. This enables the formulation of weak form equations governing the warping from shear and torsion. These weak form equations are solved...... numerically by introducing a cubic-linear two-dimensional isoparametric element. The cubic interpolation of this element accurately represents quadratic shear stress variations along cross-section walls, and thus moderately thin-walled cross-sections are effectively discretized by these elements. The ability...

  2. A gravity loading countermeasure skinsuit

    Science.gov (United States)

    Waldie, James M.; Newman, Dava J.

    2011-04-01

    Despite the use of several countermeasures, significant physiological deconditioning still occurs during long duration spaceflight. Bone loss - primarily due to the absence of loading in microgravity - is perhaps the greatest challenge to resolve. This paper describes a conceptual Gravity Loading Countermeasure Skinsuit (GLCS) that induces loading on the body to mimic standing and - when integrated with other countermeasures - exercising on Earth. Comfort, mobility and other operational issues were explored during a pilot study carried out in parabolic flight for prototype suits worn by three subjects. Compared to the 1- or 2-stage Russian Pingvin Suits, the elastic mesh of the GLCS can create a loading regime that gradually increases in hundreds of stages from the shoulders to the feet, thereby reproducing the weight-bearing regime normally imparted by gravity with much higher resolution. Modelling shows that the skinsuit requires less than 10 mmHg (1.3 kPa) of compression for three subjects of varied gender, height and mass. Negligible mobility restriction and excellent comfort properties were found during the parabolic flights, which suggests that crewmembers should be able to work normally, exercise or sleep while wearing the suit. The suit may also serve as a practical 1 g harness for exercise countermeasures and vibration applications to improve dynamic loading.

  3. Friction and anchorage loading revisited.

    Science.gov (United States)

    Dholakia, Kartik D

    2012-01-01

    Contemporary concepts of sliding mechanics explain that friction is inevitable. To overcome this frictional resistance, excess force is required to retract the tooth along the archwire (ie, individual retraction of canines, en masse retraction of anterior teeth), in addition to the amount of force required for tooth movement. The anterior tooth retraction force, in addition to excess force (to overcome friction), produces reciprocal protraction force on molars, thereby leading to increased anchorage loading. However, this traditional concept was challenged in recent literature, which was based on the finite element model, but did not bear correlation to the clinical scenario. This article will reinforce the fact that clinically, friction increases anchorage loading in all three planes of space, considering the fact that tooth movement is a quasistatic process rather than a purely continuous or static one, and that conventional ways of determining the effects of static or dynamic friction on anchorage load cannot be applied to clinical situations (which consist of anatomical resistance units and a complex muscular force system). The article does not aim to quantify friction and its effect on the amount of anchorage load. Rather, a new perspective regarding the role of various additional factors (which is not explained by contemporary concept) that may influence friction and anchorage loading is provided..

  4. Kinetics of homocysteine metabolism after moderate alcohol consumption

    NARCIS (Netherlands)

    Beulens, J.W.J.; Sierksma, A.; Schaafsma, G.; Kok, F.J.; Struys, E.A.; Jakobs, C.; Hendriks, H.F.J.

    2005-01-01

    Background: Moderate alcohol consumption is associated with a decreased risk of cardiovascular disease. Because plasma homocysteine (tHcy) is considered an independent risk factor for cardiovascular disease and associated with alcohol consumption, the authors investigated the effect of moderate

  5. Kinetics of homocysteine metabolism after moderate alcohol consumption

    NARCIS (Netherlands)

    Beulens, J.W.J.; Sierksma, A.; Schaafsma, G.; Kok, F.J.; Struys, E.A.; Jakobs, C.; Hendriks, H.F.J.

    2005-01-01

    Moderate alcohol consumption is associated with a decreased risk of cardiovascular disease. Because plasma homocysteine (tHcy) is considered an independent risk factor for cardiovascular disease and associated with alcohol consumption, the authors investigated the effect of moderate alcohol

  6. Efficiency of Capacitively Loaded Converters

    DEFF Research Database (Denmark)

    Andersen, Thomas; Huang, Lina; Andersen, Michael A. E.

    2012-01-01

    is introduced as a definition of efficiency. The calculated and measured efficiency curves for charging DEAP actuator, polypropylene film capacitor and X7R MLCC are provided and compared. The attention has to be paid for the voltage dependent capacitive load, like X7R MLCC, when evaluating the charging......This paper explores the characteristic of capacitance versus voltage for dielectric electro active polymer (DEAP) actuator, 2kV polypropylene film capacitor as well as 3kV X7R multi layer ceramic capacitor (MLCC) at the beginning. An energy efficiency for capacitively loaded converters...... polypropylene film capacitor can be the equivalent capacitive load. Because of the voltage dependent characteristic, X7R MLCC cannot be used to replace the DEAP actuator. However, this type of capacitor can be used to substitute the capacitive actuator with voltage dependent property at the development phase....

  7. Ultimate loading of wind turbines

    DEFF Research Database (Denmark)

    Larsen, Gunner Chr.; Ronold, K.; Ejsing Jørgensen, Hans

    1999-01-01

    An extreme loading study has been conducted comprising a general wind climate analysis as well as a wind turbine reliability study. In the wind climate analysis, the distribution of the (horizontal) turbulence standard deviation, conditioned on the meanwind speed, has been approximated by fitting......, a design turbulence intensity for off-shore application is proposed which, in the IEC code framework, is applicable for extreme as well as for fatigue loaddetermination. In order to establish a rational method to analyse wind turbine components with respect to failure in ultimate loading, and in addition...... to the event of failure in ultimate loading in flapwise bending in the normal operating condition of a site-specific turbine....

  8. Neutronic moderator design for the Spallation Neutron Source (SNS)

    International Nuclear Information System (INIS)

    Charlton, L.A.; Barnes, J.M.; Johnson, J.O.; Gabriel, T.A.

    1998-01-01

    Neutronics analyses are now in progress to support the initial selection of moderator design parameters for the Spallation Neutron Source (SNS). The results of the initial optimization studies involving moderator poison plate location, moderator position, and premoderator performance for the target system are presented in this paper. Also presented is an initial study of the use of a composite moderator to produce a liquid methane like spectrum

  9. Heavy water moderated reactors advances and challenges

    International Nuclear Information System (INIS)

    Meneley, D.A.; Olmstead, R.A.; Yu, A.M.; Dastur, A.R.; Yu, S.K.W.

    1994-01-01

    Nuclear energy is now considered a key contributor to world electricity production, with total installed capacity nearly equal to that of hydraulic power. Nevertheless, many important challenges lie ahead. Paramount among these is gaining public acceptance: this paper makes the basic assumption that public acceptance will improve if, and only if, nuclear power plants are operated safely and economically over an extended period of time. The first task, therefore, is to ensure that these prerequisites to public acceptance are met. Other issues relate to the many aspects of economics associated with nuclear power, include capital cost, operation cost, plant performance and the risk to the owner's investment. Financing is a further challenge to the expansion of nuclear power. While the ability to finance a project is strongly dependent on meeting public acceptance and economic challenges, substantial localisation of design and manufacture is often essential to acceptance by the purchaser. The neutron efficient heavy water moderated CANDU with its unique tube reactor is considered to be particularly well qualified to respond to these market challenges. Enhanced safety can be achieved through simplification of safety systems, design of the moderator and shield water systems to mitigate severe accident events, and the increased use of passive systems. Economics are improved through reduction in both capital and operating costs, achieved through the application of state-of-the-art technologies and economy of scale. Modular features of the design enhance the potential for local manufacture. Advanced fuel cycles offer reduction in both capital costs and fuelling costs. These cycles, including slightly enriched uranium and low grade fuels from reprocessing plants can serve to increase reactor output, reduce fuelling cost and reduce waste production, while extending resource utilisation. 1 ref., 1 tab

  10. Does depression moderate handwashing in children?

    Directory of Open Access Journals (Sweden)

    Jurgita Slekiene

    2017-08-01

    Full Text Available Abstract Background Although diarrheal diseases are preventable and treatable, they are the leading cause of child mortality and morbidity as a consequence of poor hygiene and contaminated water. Handwashing with soap is an effective method for preventing and decreasing the incidence of diarrhea. However, mental disorders such as depression can substantially moderate an individual’s ability to cope with daily life and can exert a negative influence on daily hygiene activities such as handwashing with soap, especially in children. The aim of this study was to explain the influence of depression on pupils’ hand-washing behavior in Zimbabwe. Methods In a cross-sectional study, face-to-face interviews were carried out with primary school pupils in peri-urban Harare, Zimbabwe (n = 556 using a quantitative questionnaire to assess handwashing and its behavioral determinants in school settings. The Center for Epidemiological Studies Depression Scale for Children (CES-DC was used to assess depression. Results More than half of the assessed children were depressed. Self-reported handwashing with soap among depressed children was significantly lower than among non-depressed children. Almost all behavioral determinants of hand-washing behavior were significantly lower in depressed children. The behavioral determinants worked differently in the depressed children than in the non-depressed children’s group. The effects of important behavioral determinants on handwashing were moderated by depression. Conclusions Depression exerts a negative influence on handwashing in children. These results suggest depression-relieving measures should be conducted together with any water, sanitation, and hygiene (WASH interventions to make such interventions more effective.

  11. Symplastic phloem loading in poplar.

    Science.gov (United States)

    Zhang, Cankui; Han, Lu; Slewinski, Thomas L; Sun, Jianlei; Zhang, Jing; Wang, Zeng-Yu; Turgeon, Robert

    2014-09-01

    Sap is driven through phloem sieve tubes by an osmotically generated pressure gradient between source and sink tissues. In many plants, source pressure results from thermodynamically active loading in which energy is used to transfer sucrose (Suc) from mesophyll cells to the phloem of leaf minor veins against a concentration gradient. However, in some species, almost all trees, correlative evidence suggests that sugar migrates passively through plasmodesmata from mesophyll cells into the sieve elements. The possibility of alternate loading mechanisms has important ramifications for the regulation of phloem transport and source-sink interactions. Here, we provide experimental evidence that, in gray poplar (Populus tremula × Populus alba), Suc enters the phloem through plasmodesmata. Transgenic plants were generated with yeast invertase in the cell walls to prevent Suc loading by this route. The constructs were driven either by the constitutive 35S promoter or the minor vein-specific galactinol synthase promoter. Transgenic plants grew at the same rate as the wild type without symptoms of loading inhibition, such as accumulation of carbohydrates or leaf chlorosis. Rates of photosynthesis were normal. In contrast, alfalfa (Medicago sativa) plants, which have limited numbers of plasmodesmata between mesophyll and phloem, displayed typical symptoms of loading inhibition when transformed with the same DNA constructs. The results are consistent with passive loading of Suc through plasmodesmata in poplar. We also noted defense-related symptoms in leaves of transgenic poplar when the plants were abruptly exposed to excessively high temperatures, adding to evidence that hexose is involved in triggering the hypersensitive response. © 2014 American Society of Plant Biologists. All Rights Reserved.

  12. Collagen XI mutation lowers susceptibility to load-induced cartilage damage in mice.

    Science.gov (United States)

    Holyoak, Derek T; Otero, Miguel; Armar, Naa Shidaa; Ziemian, Sophia N; Otto, Ariana; Cullinane, Devinne; Wright, Timothy M; Goldring, Steven R; Goldring, Mary B; van der Meulen, Marjolein C H

    2018-02-01

    Interactions among risk factors for osteoarthritis (OA) are not well understood. We investigated the combined impact of two prevalent risk factors: mechanical loading and genetically abnormal cartilage tissue properties. We used cyclic tibial compression to simulate mechanical loading in the cho/+ (Col11a1 haploinsufficient) mouse, which has abnormal collagen fibrils in cartilage due to a point mutation in the Col11a1 gene. We hypothesized that the mutant collagen would not alter phenotypic bone properties and that cho/+ mice, which develop early onset OA, would develop enhanced load-induced cartilage damage compared to their littermates. To test our hypotheses, we applied cyclic compression to the left tibiae of 6-month-old cho/+ male mice and wild-type (WT) littermates for 1, 2, and 6 weeks at moderate (4.5 N) and high (9.0 N) peak load magnitudes. We then characterized load-induced cartilage and bone changes by histology, microcomputed tomography, and immunohistochemistry. Prior to loading, cho/+ mice had less dense, thinner cortical bone compared to WT littermates. In addition, in loaded and non-loaded limbs, cho/+ mice had thicker cartilage. With high loads, cho/+ mice experienced less load-induced cartilage damage at all time points and displayed decreased matrix metalloproteinase (MMP)-13 levels compared to WT littermates. The thinner, less dense cortical bone and thicker cartilage were unexpected and may have contributed to the reduced severity of load-induced cartilage damage in cho/+ mice. Furthermore, the spontaneous proteoglycan loss resulting from the mutant collagen XI was not additive to cartilage damage from mechanical loading, suggesting that these risk factors act through independent pathways. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:711-720, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. The relationships between internal and external training load models during basketball training.

    Science.gov (United States)

    Scanlan, Aaron T; Wen, Neal; Tucker, Patrick S; Dalbo, Vincent J

    2014-09-01

    The present investigation described and compared the internal and external training loads during basketball training. Eight semiprofessional male basketball players (mean ± SD, age: 26.3 ± 6.7 years; stature: 188.1 ± 6.2 cm; body mass: 92.0 ± 13.8 kg) were monitored across a 7-week period during the preparatory phase of the annual training plan. A total of 44 total sessions were monitored. Player session ratings of perceived exertion (sRPE), heart rate, and accelerometer data were collected across each training session. Internal training load was determined using the sRPE, training impulse (TRIMP), and summated-heart-rate-zones (SHRZ) training load models. External training load was calculated using an established accelerometer algorithm. Pearson product-moment correlations with 95% confidence intervals (CIs) were used to determine the relationships between internal and external training load models. Significant moderate relationships were observed between external training load and the sRPE (r42 = 0.49, 95% CI = 0.23-0.69, p training load and the SHRZ model (r42 = 0.61, 95% CI = 0.38-0.77, p training load models, the magnitude of the correlations and low commonality suggest that internal training load models measure different constructs of the training process than the accelerometer training load model in basketball settings. Basketball coaching and conditioning professionals should not assume a linear dose-response between accelerometer and internal training load models during training and are recommended to combine internal and external approaches when monitoring training load in players.

  14. electrical load survey electrical load survey and forecast

    African Journals Online (AJOL)

    eobe

    This paper presents e. This paper presents electrical l lectrical l lectrical load survey and f urvey and f urvey and forecast for a typical off orecast for a typical off orecast for a typical off-grid rural decentralized hybrid power grid rural decentralized hybrid power generating systems of a rural area (Elebu) generating systems of a ...

  15. Moderately preterm children need attention! : Behavior and development of moderately preterm children at toddler age

    NARCIS (Netherlands)

    de Jong, M.

    2016-01-01

    Every year, more than 10.000 children in the Netherlands are born moderately preterm after 32 to 36+6 weeks of gestation, which is 6.1% of all births. These children are at risk for difficulties on the short and long term. Previous studies especially found academic problems and difficulties in

  16. Method for loading resin beds

    International Nuclear Information System (INIS)

    Notz, K.J.; Rainey, R.H.; Greene, C.W.; Shockley, W.E.

    1978-01-01

    An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145 to 200 0 C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145 0 C with a second aqueous component to provide a gaseous phase containing HNO 3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate

  17. Nuclear fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    Gerkey, K.S.

    1979-01-01

    An automatic apparatus for loading a predetermined amount of nuclear fuel pellets into a nuclear fuel element to be used in a nuclear reactor is described. The apparatus consists of a vibratory bed capable of supporting corrugated trays containing rows of nuclear fuel pellets and arranged in alignment with the open ends of several nuclear fuel elements. A sweep mechanism is arranged above the trays and serves to sweep the rows of fuel pellets onto the vibratory bed and into the fuel element. A length detecting system, in conjunction with a pellet stopping mechanism, is also provided to assure that a predetermined amount of nuclear fuel pellets are loaded into each fuel element

  18. Circular mats under arbitrary loading

    International Nuclear Information System (INIS)

    Banerjee, A.; Jankov, Z.D.

    1975-01-01

    The analysis of mats as in nuclear power plants may become difficult when the large number of features are intended to be accounted for. Circular mats and arbitrary loadings are only a few of these that are considered. If the subgrade reaction can be represented as the function of subgrade displacement as given by Winkler's, Boussinesq's, or two elastic characteristic approaches, the general numerical method is then possible. Boussinesq's approach was treated in more detail when applied on circular mat with arbitrary loadings. Full polar grid formation that must be used when liftoff occurs is compared to harmonic formulation. The possibility of taking into account the superstructure restraint is indicated

  19. Seismic capacity of a reinforced concrete frame structure without seismic detailing and limited ductility seismic design in moderate seismicity

    International Nuclear Information System (INIS)

    Kim, J. K.; Kim, I. H.

    1999-01-01

    A four-story reinforced concrete frame building model is designed for the gravity loads only. Static nonlinear pushover analyses are performed in two orthogonal horizontal directions. The overall capacity curves are converted into ADRS spectra and compared with demand spectra. At several points the deformed shape, moment and shear distribution are calculated. Based on these results limited ductility seismic design concept is proposed as an alternative seismic design approach in moderate seismicity resign

  20. A Survey on the Ship Loading Problem

    DEFF Research Database (Denmark)

    Iris, Cagatay; Pacino, Dario

    2015-01-01

    on externalities. One of those is the ship loading process. Based on the stowage plan received by liner shippers, terminal operators plan the execution of load and discharge operations. In this paper we present a literature review for the Ship Loading Problem, where stowage and loading sequencing and scheduling...

  1. 46 CFR 169.689 - Demand loads.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Demand loads. 169.689 Section 169.689 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.689 Demand loads. Demand loads must meet § 111.60-7 of this chapter except that smaller demand loads for motor feeders are...

  2. The moderating effects of sample type as evidence of the effects of faking on personality scale correlations and factor structure

    Directory of Open Access Journals (Sweden)

    KEVIN M. BRADLEY

    2006-09-01

    Full Text Available Motivational differences as a function of sample type (applicants versus incumbents have frequently been suspected of causing meaningful differences in the psychometric properties of personality inventories due to the effects of faking. In this quantitative review, correlations among the Big Five personality constructs were estimated and sample type was examined as a potential moderator of the personality construct inter-correlations. The resulting subgroup meta-analytic correlation matrices were factor-analyzed, and the second order factor solutions for job incumbents and job applicants were compared. Results of the meta-analyses indicate frequent, but small moderating effects. The second order factor analyses indicated that the observed moderation had little effect on the congruence of factor loadings. Together, the results are consistent with the position that faking is of little practical consequence in selection settings.

  3. Experimental investigation of ultimate loads

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, S.M.; Larsen, G.C.; Antoniou, I.; Lind, S.O.; Courtney, M. [Risoe National Lab., Wind Energy and Atmospheric Physics, Roskilde (Denmark)

    1999-03-01

    Verification of the structural integrity of a wind turbine involves analysis of fatigue loading as well as ultimate loading. With the trend of persistently growing turbines, the ultimate loading seems to become relatively more important. For wind turbines designed according to the wind conditions prescribed in the IEC-61400 code, the ultimate load is often identified as the leading load parameter. Exemplified by the use of an extensive measurement campaign a procedure for evaluation of the extreme flap-wise bending moments, occurring during normal operating of a wind turbine, is presented. The structural measurements are made on a NEG Micon 650 kW wind turbine erected at a complex high wind site in Oak Creek, California. The turbine is located on the top of a ridge. The prevailing wind direction is perpendicular to the ridge, and the annual mean wind speed is 9.5 m/s. The associated wind field measurement, are taken from two instrumented masts erected less than one rotor diameter in front of the turbine in direction of the prevailing wind direction. Both masts are instrumented at different heights in order to gain insight of the 3D-wind speed structure over the entire rotor plane. Extreme distributions, associated with a recurrence period of 10 minutes, conditioned on the mean wind speed and the turbulence intensity are derived. Combined with the wind climate model proposed in the IEC standard, these distributions are used to predict extreme distributions with recurrence periods equal to one and fifty years, respectively. The synthesis of the conditioned PDF`s and the wind climate model is performed by means of Monte Carlo simulation. (au)

  4. Society. Part II: moderate to severe psoriasis

    Directory of Open Access Journals (Sweden)

    Jacek Szepietowski

    2014-11-01

    Full Text Available Psoriasis is a chronic inflammatory skin disease affecting about 1–3% of the general population. Recent years have seen great development in the treatment of this dermatosis, especially regarding moderate to severe psoriasis. More numerous and more widely available systemic therapies raise new challenges for all physicians treating patients with psoriasis. New questions arise about patients’ follow-up and long-term safety of such therapies. To meet the expectations of Polish dermatologists, we have prepared a second part of guidelines on the treatment of psoriasis, particularly concentrated on the therapy of severe forms of this disease. We hope that our suggestions will be valuable for physicians in their daily clinical practice. However, we would like to underline that every guideline is characterized by some vagueness, and the final decision about diagnosis and therapy should always be made individually for every patient based on the patient’s current clinical status and the most up-to-date scientific literature data.

  5. Microclimate moderates plant responses to macroclimate warming.

    Science.gov (United States)

    De Frenne, Pieter; Rodríguez-Sánchez, Francisco; Coomes, David Anthony; Baeten, Lander; Verstraeten, Gorik; Vellend, Mark; Bernhardt-Römermann, Markus; Brown, Carissa D; Brunet, Jörg; Cornelis, Johnny; Decocq, Guillaume M; Dierschke, Hartmut; Eriksson, Ove; Gilliam, Frank S; Hédl, Radim; Heinken, Thilo; Hermy, Martin; Hommel, Patrick; Jenkins, Michael A; Kelly, Daniel L; Kirby, Keith J; Mitchell, Fraser J G; Naaf, Tobias; Newman, Miles; Peterken, George; Petrík, Petr; Schultz, Jan; Sonnier, Grégory; Van Calster, Hans; Waller, Donald M; Walther, Gian-Reto; White, Peter S; Woods, Kerry D; Wulf, Monika; Graae, Bente Jessen; Verheyen, Kris

    2013-11-12

    Recent global warming is acting across marine, freshwater, and terrestrial ecosystems to favor species adapted to warmer conditions and/or reduce the abundance of cold-adapted organisms (i.e., "thermophilization" of communities). Lack of community responses to increased temperature, however, has also been reported for several taxa and regions, suggesting that "climatic lags" may be frequent. Here we show that microclimatic effects brought about by forest canopy closure can buffer biotic responses to macroclimate warming, thus explaining an apparent climatic lag. Using data from 1,409 vegetation plots in European and North American temperate forests, each surveyed at least twice over an interval of 12-67 y, we document significant thermophilization of ground-layer plant communities. These changes reflect concurrent declines in species adapted to cooler conditions and increases in species adapted to warmer conditions. However, thermophilization, particularly the increase of warm-adapted species, is attenuated in forests whose canopies have become denser, probably reflecting cooler growing-season ground temperatures via increased shading. As standing stocks of trees have increased in many temperate forests in recent decades, local microclimatic effects may commonly be moderating the impacts of macroclimate warming on forest understories. Conversely, increases in harvesting woody biomass--e.g., for bioenergy--may open forest canopies and accelerate thermophilization of temperate forest biodiversity.

  6. Moderating Effects of Sales Promotion Types

    Directory of Open Access Journals (Sweden)

    Fernando de Oliveira Santini

    2015-04-01

    Full Text Available This paper aims to analyze the influence sales promotion types have on the relationship between perception of financial risk and perception of utilitarian and hedonic value on consumer purchase intentions. To this end, an experiment was conducted involving 589 participants divided into two groups defined by distinct scenarios in which the sales promotion type (monetary vs. non-monetary was manipulated. The working hypotheses predicted a direct and positive relationship between the perception of (hedonic and utilitarian consumption value and purchase intention for a promoted product and a negative relationship between the perception of consumption value and the perception of financial risk. In addition, it was supposed that the sales promotion type would moderate these direct relationships and that a monetary promotion would have a stronger effect on the relationship between purchase intention and perceived product utility, whereas a non-monetary promotion would have a stronger effect on the other relationships (hedonic value and financial risk perceptions. Analysis of the outcomes supported the proposed hypotheses.

  7. Moderate excess of pyruvate augments osteoclastogenesis

    Directory of Open Access Journals (Sweden)

    Jenna E. Fong

    2013-03-01

    Cell differentiation leads to adaptive changes in energy metabolism. Conversely, hyperglycemia induces malfunction of many body systems, including bone, suggesting that energy metabolism reciprocally affects cell differentiation. We investigated how the differentiation of bone-resorbing osteoclasts, large polykaryons formed through fusion and growth of cells of monocytic origin, is affected by excess of energy substrate pyruvate and how energy metabolism changes during osteoclast differentiation. Surprisingly, small increases in pyruvate (1–2 mM above basal levels augmented osteoclastogenesis in vitro and in vivo, while larger increases were not effective in vitro. Osteoclast differentiation increased cell mitochondrial activity and ATP levels, which were further augmented in energy-rich conditions. Conversely, the inhibition of respiration significantly reduced osteoclast number and size. AMP-activated protein kinase (AMPK acts as a metabolic sensor, which is inhibited in energy-rich conditions. We found that osteoclast differentiation was associated with an increase in AMPK levels and a change in AMPK isoform composition. Increased osteoclast size induced by pyruvate (1 mM above basal levels was prevented in the presence of AMPK activator 5-amino-4-imidazole carboxamide ribonucleotide (AICAR. In keeping, inhibition of AMPK using dorsomorphin or siRNA to AMPKγ increased osteoclast size in control cultures to the level observed in the presence of pyruvate. Thus, we have found that a moderate excess of pyruvate enhances osteoclastogenesis, and that AMPK acts to tailor osteoclastogenesis to a cell's bioenergetics capacity.

  8. Pressure fluctuation caused by moderate acceleration

    Science.gov (United States)

    Tagawa, Yoshiyuki; Kurihara, Chihiro; Kiyama, Akihito

    2017-11-01

    Pressure fluctuation caused by acceleration of a liquid column is observed in various important technologies, e.g. water-hammer in a pipeline. The magnitude of fluctuation can be estimated by two different approaches: When the duration time of acceleration is much shorter than the propagation time for a pressure wave to travel the length of the liquid column, e.g. sudden valve closure for a long pipe, Joukowsky equation is applied. In contrast, if the acceleration duration is much longer, the liquid is modeled as a rigid column, ignoring compressibility of the fluid. However, many of practical cases exist between these two extremes. In this study we propose a model describing pressure fluctuation when the duration of acceleration is in the same order of the propagation time for a pressure wave, i.e. under moderate acceleration. The novel model considers both temporal and spatial evolutions of pressure propagation as well as gradual pressure rise during the acceleration. We conduct experiments in which we impose acceleration to a liquid with varying the length of the liquid column, acceleration duration, and properties of liquids. The ratio between the acceleration duration and the propagation time is in the range of 0.02 - 2. The model agrees well with measurement results. JSPS KAKENHI Grant Numbers 26709007 and 17H01246.

  9. Moderate-to-high intensity aerobic exercise in patients with mild to moderate Alzheimer's disease

    DEFF Research Database (Denmark)

    Frederiksen, Kristian S; Sobol, Nanna; Beyer, Nina

    2014-01-01

    OBJECTIVES: Physical exercise may modulate neuropathology and symptoms of Alzheimer's disease (AD). This pilot study assessed the feasibility of conducting a study of moderate-to-high intensity aerobic exercise in home-dwelling patients with mild AD. METHODS: An uncontrolled preintervention......-postintervention test design with a single group receiving the same intervention. A total of eight patients with mild to moderate AD from the Copenhagen Memory clinic were included in the study. The intervention lasted for 14 weeks and consisted of supervised, 1-h sessions of aerobic exercise three times per week (50......-to-high intensity aerobic exercise in community-dwelling patients with mild AD. Our findings indicate that aspects such as a longer adaptation period, information about injury prevention, and need for involvement and support from caregivers should be addressed when planning an exercise intervention in an AD...

  10. First experience with the new solid methane moderator at the IBR-2 reactor

    International Nuclear Information System (INIS)

    Beliakov, A.A.; Shabalin, E.P.; Tretyakov, I.T.

    2001-01-01

    In the 1999 Fall the solid methane moderator (CM) has been installed and tested at full power at the IBR-2 pulsed reactor. Its main features are a beryllium reflector and a light water premoderator. Radiation load on the methane was three times as much as that of IPNS facility, namely, 0.1 W/g. Effects of temperature, operation time, concentration of a hydrogen scavenger, and annealing procedure on both neutron and service performances were studied. Maximum operation time of a newly loaded portion of methane was 4 days. In this time around 30% of methane is transformed into hydrogen, ethane, and high molecular hydrocarbons, and yet no deterioration in cold neutron intensity was detected. Among new knowledge, the most important are two facts observed: two-fold decrease in hydrogen formation rate when methane is poisoned with 2.5% to 5% of ethylene, and low formation rate of solid, inremovable products of radiolysis - (1.5/3)10 -7 g/J, which means that after 10 years of operation the methane chamber will be filled with only 100 g of residue. Gain of factor 20 in cold neutron flux was obtained as compared to the routine grooved light water moderator. Presently, it is the highest among the intense pulsed neutron sources. (author)

  11. 46 CFR 154.1730 - Ethylene oxide: Loading and off loading.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ethylene oxide: Loading and off loading. 154.1730... Operating Requirements § 154.1730 Ethylene oxide: Loading and off loading. (a) The master shall ensure that before ethylene oxide is loaded into a cargo tank: (1) The tank is thoroughly clean, dry, and free of...

  12. The Effects of Load Distribution and Gradient on Load Carriage

    Science.gov (United States)

    2010-12-01

    while 11 participants walked on a smooth level surface. EMG is a medical technique used to measure the response of muscle and nerve activity to...Expert Infantryman’s Badge EMG Electromyography ESQ Environmental Symptoms Questionnaire HFE Human Factors Engineering HR Heart Rate HRV...factors can directly and indirectly affect the efficiency of load carriage as it relates to exposure to injury, fatigue , and ability to complete a

  13. Developing models of how cognitive improvements change functioning: mediation, moderation and moderated mediation.

    Science.gov (United States)

    Wykes, Til; Reeder, Clare; Huddy, Vyv; Taylor, Rumina; Wood, Helen; Ghirasim, Natalia; Kontis, Dimitrios; Landau, Sabine

    2012-06-01

    Cognitive remediation (CRT) affects functioning but the extent and type of cognitive improvements necessary are unknown. To develop and test models of how cognitive improvement transfers to work behaviour using the data from a current service. Participants (N49) with a support worker and a paid or voluntary job were offered CRT in a Phase 2 single group design with three assessments: baseline, post therapy and follow-up. Working memory, cognitive flexibility, planning and work outcomes were assessed. Three models were tested (mediation - cognitive improvements drive functioning improvement; moderation - post treatment cognitive level affects the impact of CRT on functioning; moderated mediation - cognition drives functioning improvements only after a certain level is achieved). There was evidence of mediation (planning improvement associated with improved work quality). There was no evidence that cognitive flexibility (total Wisconsin Card Sorting Test errors) and working memory (Wechsler Adult Intelligence Scale III digit span) mediated work functioning despite significant effects. There was some evidence of moderated mediation for planning improvement if participants had poorer memory and/or made fewer WCST errors. The total CRT effect on work quality was d=0.55, but the indirect (planning-mediated CRT effect) was d=0.082 Planning improvements led to better work quality but only accounted for a small proportion of the total effect on work outcome. Other specific and non-specific effects of CRT and the work programme are likely to account for some of the remaining effect. This is the first time complex models have been tested and future Phase 3 studies need to further test mediation and moderated mediation models. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Everything in Moderation: Moderate Use of Screens Unassociated with Child Behavior Problems.

    Science.gov (United States)

    Ferguson, Christopher J

    2017-12-01

    The impact of children's use of "screen" media including television and computer games, continues to be debated. The American Academy of Pediatrics (AAP) until recently recommended a relatively restrictive screen time diet of 2 h or less for most youth. A representative correlational sample of youth were assessed for links between screen time and risky behavioral outcomes. Data collection occurred in 2013 conducted by the State of Florida. Use of screens that was moderately high, in excess of the AAP's former recommendations, but not excessive (1 SD or higher than average), was not associated with delinquency, risky behaviors, sexual behaviors, substance abuse, reduced grades or mental health problems. Even excessive screen use (1 SD or higher) was only weakly associated with negative outcomes related to delinquency, grades and depression only, and at levels unlikely to be practically significant. Results conceptually replicate those of Przybylski (2014) with a US sample for depression and delinquency as outcomes. Moderate use of screens, though in excess of the AAP's historical recommendations, are unassociated with problem outcomes. Excessive use of screens is only weakly associated with negative outcomes, and only those related to depression and delinquency as well as reduced grades, but not risky driving, substance use, risky sex or disordered eating. Although an "everything in moderation" message when discussing screen time with parents may be most productive, results do not support a strong focus on screen time as a preventative measure for youth problem behaviors.

  15. Climate control loads prediction of electric vehicles

    International Nuclear Information System (INIS)

    Zhang, Ziqi; Li, Wanyong; Zhang, Chengquan; Chen, Jiangping

    2017-01-01

    Highlights: • A model of vehicle climate control loads is proposed based on experiments. • Main climate control loads of the modeled vehicle are quantitatively analyzed. • Range reductions of the modeled vehicle under different conditions are simulated. - Abstract: A new model of electric vehicle climate control loads is provided in this paper. The mathematical formulations of the major climate control loads are developed, and the coefficients of the formulations are experimentally determined. Then, the detailed climate control loads are analyzed, and the New European Driving Cycle (NEDC) range reductions due to these loads are calculated under different conditions. It is found that in an electric vehicle, the total climate control loads vary with the vehicle speed, HVAC mode and blower level. The ventilation load is the largest climate control load, followed by the solar radiation load. These two add up to more than 80% of total climate control load in summer. The ventilation load accounts for 70.7–83.9% of total heating load under the winter condition. The climate control loads will cause a 17.2–37.1% reduction of NEDC range in summer, and a 17.1–54.1% reduction in winter, compared to the AC off condition. The heat pump system has an advantage in range extension. A heat pump system with an average heating COP of 1.7 will extend the range by 7.6–21.1% based on the simulation conditions.

  16. Spinning Reserve From Responsive Loads

    Energy Technology Data Exchange (ETDEWEB)

    Kirby, B.J.

    2003-04-08

    Responsive load is the most underutilized reliability resource available to the power system today. It is currently not used at all to provide spinning reserve. Historically there were good reasons for this, but recent technological advances in communications and controls have provided new capabilities and eliminated many of the old obstacles. North American Electric Reliability Council (NERC), Federal Energy Regulatory Commission (FERC), Northeast Power Coordinating Council (NPCC), New York State Reliability Council (NYSRC), and New York Independent System Operator (NYISO) rules are beginning to recognize these changes and are starting to encourage responsive load provision of reliability services. The Carrier ComfortChoice responsive thermostats provide an example of these technological advances. This is a technology aimed at reducing summer peak demand through central control of residential and small commercial air-conditioning loads. It is being utilized by Long Island Power Authority (LIPA), Consolidated Edison (ConEd), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). The technology is capable of delivering even greater response in the faster spinning reserve time frame (while still providing peak reduction). Analysis of demand reduction testing results from LIPA during the summer of 2002 provides evidence to back up this claim. It also demonstrates that loads are different from generators and that the conventional wisdom, which advocates for starting with large loads as better ancillary service providers, is flawed. The tempting approach of incrementally adapting ancillary service requirements, which were established when generators were the only available resources, will not work. While it is easier for most generators to provide replacement power and non-spinning reserve (the slower response services) than it is to supply spinning reserve (the fastest service), the opposite is true for many loads. Also, there is more financial

  17. Phosphorous loads evaluation from soil

    International Nuclear Information System (INIS)

    Mezzanotte, V.

    1996-01-01

    With reference to the well known difficulty of quantifying non point phosphorous loads, as well as to their growing relative importance where point source leads decrease, a literature review has been carried out concerning soil export coefficients. On such basis, the values which seem to be the most appropriate for Italy have been estimated for different land use categories. The main mechanisms determining non point phosphorous load generation and the factors affecting their importance are also described. In the end, criteria for estimating the importance of non point sources in a basin are suggested to be used for deciding whether a traditional, parametric assessment (inevitably involving a certain error) can be acceptable or experimental measures are needed

  18. Auditory perceptual load: A review.

    Science.gov (United States)

    Murphy, Sandra; Spence, Charles; Dalton, Polly

    2017-09-01

    Selective attention is a crucial mechanism in everyday life, allowing us to focus on a portion of incoming sensory information at the expense of other less relevant stimuli. The circumstances under which irrelevant stimuli are successfully ignored have been a topic of scientific interest for several decades now. Over the last 20 years, the perceptual load theory (e.g. Lavie, 1995) has provided one robust framework for understanding these effects within the visual modality. The suggestion is that successful selection depends on the perceptual demands imposed by the task-relevant information. However, less research has addressed the question of whether the same principles hold in audition and, to date, the existing literature provides a mixed picture. Here, we review the evidence for and against the applicability of perceptual load theory in hearing, concluding that this question still awaits resolution. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Stateful load balancing for parallel stream processing

    DEFF Research Database (Denmark)

    Guo, Qingsong; Zhou, Yongluan

    2018-01-01

    Timely processing of streams in parallel requires dynamic load balancing to diminish skewness of data. In this paper we study this problem for stateful operators with key grouping for which the process of load balancing involves a lot of state movements. Consequently, load balancing is a bi......-objective optimization problem, namely Minimum-Cost-Load-Balance (MCLB). We address MCLB with two approximate algorithms by a certain relaxation of the objectives: (1) a greedy algorithm ELB performs load balancing eagerly but relaxes the objective of load imbalance to a range; and (2) a periodic algorithm CLB aims...

  20. Energetics of load carrying in Nepalese porters.

    Science.gov (United States)

    Bastien, Guillaume J; Schepens, Bénédicte; Willems, Patrick A; Heglund, Norman C

    2005-06-17

    Nepalese porters routinely carry head-supported loads equal to 100 to 200% of their body weight (Mb) for many days up and down steep mountain footpaths at high altitudes. Previous studies have shown that African women carry head-supported loads of up to 60% of their Mb far more economically than army recruits carrying equivalent loads in backpacks. Here we show that Nepalese porters carry heavier loads even more economically than African women. Female Nepalese porters, for example, carry on average loads that are 10% of their Mb heavier than the maximum loads carried by the African women, yet do so at a 25% smaller metabolic cost.

  1. The DEMO wall load challenge

    Czech Academy of Sciences Publication Activity Database

    Wenninger, R.; Albanese, R.; Ambrosino, R.; Arbeiter, F.; Aubert, J.; Bachmann, C.; Barbato, L.; Barrett, T.; Beckers, M.; Biel, W.; Boccaccini, L.; Carralero, D.; Coster, D.; Eich, T.; Fasoli, A.; Federici, G.; Firdaouss, M.; Graves, J.; Horáček, Jan; Kovari, M.; Lanthaler, S.; Loschiavo, V.; Lowry, C.; Lux, H.; Maddaluno, G.; Maviglia, F.; Mitteau, R.; Neu, R.; Pfefferle, D.; Schmid, K.; Siccinio, M.; Sieglin, B.; Silva, C.; Snicker, A.; Subba, F.; Varje, J.; Zohm, H.

    2017-01-01

    Roč. 57, č. 4 (2017), č. článku 046002. ISSN 0029-5515 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : DEMO * power loads * first wall Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/1741-4326/aa4fb4

  2. Passive detection of vehicle loading

    Science.gov (United States)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; Salvaggio, Philip S.; McKeown, Donald M.; Garrett, Alfred J.; Coleman, David H.; Koffman, Larry D.

    2012-01-01

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  3. PASSIVE DETECTION OF VEHICLE LOADING

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, A.

    2012-01-03

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  4. Simple model for dice loading

    Science.gov (United States)

    Nagler, Jan; Richter, Peter H.

    2010-03-01

    Dice tossing is commonly believed to be random. However, throwing a fair cube is a dissipative process that is well described by deterministic classical mechanics. In Nagler and Richter (2008 Phys. Rev. E 78 036207; featured in 2008 Nature 455 434), we proposed a simplified model to analyze the origin of the pseudorandomness: a barbell with two masses at its tips with only two final outcomes. In order to keep things simple, we focused on the symmetrical case of equal masses. Here, we complete the picture by considering the general asymmetric case of unequal masses. We show how, depending on the initial conditions, dissipation during bounces, and mass asymmetry, the degree of unpredictability varies. Our analysis reveals, for the simplest possible non-trivial dice throwing model, the effect of dice loading. A surprising consequence of dynamical resonances is that an experienced player may benefit sometimes more from an unloaded than from a loaded barbell. In addition, we investigate the influence of loading on the symmetry breaking process causing one mass to come to rest earlier than the others.

  5. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  6. Genesis of elevated aerosol loading over the Indian region

    Science.gov (United States)

    Prijith, S. S.; Rao, P. V. N.; Mohan, Mannil

    2016-05-01

    Elevated aerosols assume importance as the diabatic heating due to aerosol absorption is more intense at higher altitudes where the atmosphere becomes thinner. Indian region, especially its central and northern latitudes, experiences significant loading of elevated aerosols during pre-monsoon and summer months. Genesis of elevated aerosol loading over Indian region is investigated in the present study, using multi-year satellite observations from Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) and Moderate Resolution Imaging Spectroradiometer (MODIS) along with reanalysis winds from MERRA. Central India is observed to have prominent aerosols loading at higher altitudes during pre-monsoon season, whereas it is during summer months over north-west India. Further analysis reveals that the elevated aerosols over Indian region in pre-monsoon and summer months are significantly contributed by transported mineral dust from the arid continental regions at west. In addition to the mineral dust advection, aerosols at higher altitudes over Indian region are enriched by strong convection and associated vertical transport of surface level aerosols. Vertical transport of aerosols observed over Indian region during pre-monsoon and summer months is aided by intense convergence at the surface level and divergence at the upper level. Moreover, aerosol source/sink strength estimated using aerosol flux continuity equation show significant aerosol production over central India during pre-monsoon. Strong vertical transport prevails during pre-monsoon uplifts the locally produced aerosols, with considerable anthropogenic fraction, to higher altitudes where their impacts would be more intense.

  7. Studying the Laws of the Thermoviscoplastic Deformation of a Solid Under Nonisothermal Complex Loading. Part 2

    Science.gov (United States)

    Shevchenko, Yu. N.; Terekhov, R. G.

    2001-06-01

    The studies made at the thermoplasticity department of the S. P. Timoshenko Institute of Mechanics are analyzed. These studies involve experimental validations of the kinematic equation of creep damage and the constitutive equations describing simple thermoviscoelastoplastic loading, with history, of isotropic and transversally isotropic bodies, for elastoviscoplastic deformation of bodies along slightly curved paths, for complex loading along arbitrary paths lying either in a plane arbitrarily oriented in the five-dimensional space of stresses or in one coordinate plane, and for elastoplastic deformation of a body's elements along paths of moderate curvature and small torsion

  8. Planning of physical load of annual cycle of students’, practicing cyclic kinds of sports, training

    Directory of Open Access Journals (Sweden)

    R.S. Nagovitsyn

    2017-06-01

    Full Text Available Purpose: to offer the variant of physical load’s distribution in annual cycle of students’, practicing cyclic kinds of sports training. Material: in the research pedagogic HEE students, specializing in skiing and light athletic participated (n=18 - boys, n=8 -girls, age - 18-23 years. The students were divided into two groups: experimental and control. Results: by comparison we determined the following: volume and intensity of physical load in micro-cycle and macro-cycle; indicators of cyclic load’s distribution in year plan of students’ training. In cyclic group of skiers we used the method of standard-interval and alternative exercises. I.e. exercises of one load are fulfilled repeatedly. Other method implies variable, increasing or decreasing physical load. Cyclic load, fulfilled at heart beats rate of 160-190 bpm, accented on intensity, prevails. The main requirement is: fulfillment of movements with maximal quickness. In group of light athletic sportsmen the method of standard - continuous exercises, implying moderate intensity, was used. For example: standard current exercises - passing distance of 3 km, 5 km or 10 km. Cyclic load, fulfilled at heart beats rate of 140-160 bpm, accented on volume. Conclusions: In cyclic load of light athletic group aerobic character of work prevails. In cyclic load of skiers’ group mixed and anaerobic character of work prevails.

  9. Computation of trunk muscle forces, spinal loads and stability in whole-body vibration

    Science.gov (United States)

    Bazrgari, B.; Shirazi-Adl, A.; Kasra, M.

    2008-12-01

    Whole-body vibration has been indicated as a risk factor in back disorders. Proper prevention and treatment management, however, requires a sound knowledge of associated muscle forces and loads on the spine. Previous trunk model studies have either neglected or over-simplified the trunk redundancy with time-varying unknown muscle forces. Trunk stability has neither been addressed. A novel iterative dynamic kinematics-driven approach was employed to evaluate muscle forces, spinal loads and system stability in a seated subject under a random vertical base excitation with ˜±1 g peak acceleration contents. This iterative approach satisfied equations of motion in all directions/levels while accounting for the nonlinear passive resistance of the ligamentous spine. The effect of posture, co-activity in abdominal muscles and changes in buttocks stiffness were also investigated. The computed vertical accelerations were in good agreement with measurements. The input base excitation, via inertial and muscle forces, substantially influenced spinal loads and system stability. The flexed posture in sitting increased the net moment, muscle forces and passive spinal loads while improving the trunk stability. Similarly, the introduction of low to moderate antagonistic coactivity in abdominal muscles increased the passive spinal loads and improved the spinal stability. A trade-off, hence, exists between lower muscle forces and spinal loads on one hand and more stable spine on the other. Base excitations with larger peak acceleration contents substantially increase muscle forces/spinal loads and, hence, the risk of injury.

  10. Long-term effects of inhaled corticosteroids on sputum bacterial and viral loads in COPD.

    Science.gov (United States)

    Contoli, Marco; Pauletti, Alessia; Rossi, Maria Rita; Spanevello, Antonio; Casolari, Paolo; Marcellini, Andrea; Forini, Giacomo; Gnesini, Giulia; Marku, Brunilda; Barnes, Neil; Rizzi, Andrea; Curradi, Giacomo; Caramori, Gaetano; Morelli, Paolo; Papi, Alberto

    2017-10-01

    Inhaled corticosteroid-containing medications reduce the frequency of COPD exacerbations (mainly infectious in origin) while paradoxically increasing the risk of other respiratory infections . The aim was to determine the effects of inhaled corticosteroids on airway microbial load in COPD patients and evaluate the influence of the underlying inflammatory profile on airway colonisation and microbiome.This is a proof-of-concept prospective, randomised, open-label, blinded endpoint study. Sixty patients with stable moderate COPD were randomised to receive one inhalation twice daily of either a combination of salmeterol 50 μg plus fluticasone propionate 500 μg or salmeterol 50 μg for 12 months. The primary outcome was the change of sputum bacterial loads over the course of treatment.Compared with salmeterol, 1-year treatment with salmeterol plus fluticasone was associated with a significant increase in sputum bacterial load (p=0.005), modification of sputum microbial composition and increased airway load of potentially pathogenic bacteria. The increased bacterial load was observed only in inhaled corticosteroid-treated patients with lower baseline sputum or blood eosinophil (≤2%) levels but not in patients with higher baseline eosinophils.Long-term inhaled corticosteroid treatment affects bacterial load in stable COPD. Lower eosinophil counts are associated with increased airway bacterial load. Copyright ©ERS 2017.

  11. Moderate-Load Muscular Endurance Strength Training Did Not Improve Peak Power or Functional Capacity in Older Men and Women.

    Science.gov (United States)

    Walker, Simon; Haff, Guy G; Häkkinen, Keijo; Newton, Robert U

    2017-01-01

    The present study determined the effects of muscular endurance strength training on maximum strength and power, functional capacity, muscle activation and hypertrophy in older men and women. Eighty-one men and women acted as an intervention group while 22 acted as non-training controls (age range 64-75 y). Intervention training included super-sets (i.e., paired exercises, immediately performing the second exercises following completion of the first) with short rest intervals (30-60 s between sets) at an intensity of 50-60% one-repetition maximum (1-RM) for 15-20 repetitions. Concentric leg press actions measured maximum strength (1-RM) and concentric peak power. Functional capacity was assessed by maximum speed walking tests (i.e., forward walk, backward walk, timed-up-and-go, and stair climb tests). Quadriceps muscle activation was assessed by surface electromyogram and twitch interpolation technique. Vastus lateralis cross-sectional area was measured by panoramic ultrasound. Compared to control, the intervention groups increased maximum strength (1-RM; men: 10 ± 7% vs. 2 ± 3%, women: 14 ± 9% vs. 1 ± 6% both P vs. -3 ± 6%, women: 10 ± 10% vs. 0 ± 4% both P vs. -4 ± 3%, women: -5 ± 6% vs. -2 ± 5% both P > 0.05). While benefits occurred during muscular endurance strength training, specific stimuli are probably needed to target all aspects of age-related health.

  12. Moderate-Load Muscular Endurance Strength Training Did Not Improve Peak Power or Functional Capacity in Older Men and Women

    OpenAIRE

    Walker, Simon; Haff, Guy G.; Häkkinen, Keijo; Newton, Robert U.

    2017-01-01

    The present study determined the effects of muscular endurance strength training on maximum strength and power, functional capacity, muscle activation and hypertrophy in older men and women. Eighty-one men and women acted as an intervention group while 22 acted as non-training controls (age range 64–75 y). Intervention training included super-sets (i.e., paired exercises, immediately performing the second exercises following completion of the first) with short rest intervals (30–60 s between ...

  13. Moderate-Load Muscular Endurance Strength Training Did Not Improve Peak Power or Functional Capacity in Older Men and Women

    Directory of Open Access Journals (Sweden)

    Simon Walker

    2017-09-01

    Full Text Available The present study determined the effects of muscular endurance strength training on maximum strength and power, functional capacity, muscle activation and hypertrophy in older men and women. Eighty-one men and women acted as an intervention group while 22 acted as non-training controls (age range 64–75 y. Intervention training included super-sets (i.e., paired exercises, immediately performing the second exercises following completion of the first with short rest intervals (30–60 s between sets at an intensity of 50–60% one-repetition maximum (1-RM for 15–20 repetitions. Concentric leg press actions measured maximum strength (1-RM and concentric peak power. Functional capacity was assessed by maximum speed walking tests (i.e., forward walk, backward walk, timed-up-and-go, and stair climb tests. Quadriceps muscle activation was assessed by surface electromyogram and twitch interpolation technique. Vastus lateralis cross-sectional area was measured by panoramic ultrasound. Compared to control, the intervention groups increased maximum strength (1-RM; men: 10 ± 7% vs. 2 ± 3%, women: 14 ± 9% vs. 1 ± 6% both P < 0.01 and vastus lateralis cross-sectional area (men: 6 ± 7% vs. −3 ± 6%, women: 10 ± 10% vs. 0 ± 4% both P < 0.05. But there were no between-group differences in peak power, muscle activation or functional capacity (e.g., stair climb; men: −5 ± 7% vs. −4 ± 3%, women: −5 ± 6% vs. −2 ± 5% both P > 0.05. While benefits occurred during muscular endurance strength training, specific stimuli are probably needed to target all aspects of age-related health.

  14. Efficient Load Scheduling Method For Power Management

    Directory of Open Access Journals (Sweden)

    Vijo M Joy

    2015-08-01

    Full Text Available An efficient load scheduling method to meet varying power supply needs is presented in this paper. At peak load times the power generation system fails due to its instability. Traditionally we use load shedding process. In load shedding process disconnect the unnecessary and extra loads. The proposed method overcomes this problem by scheduling the load based on the requirement. Artificial neural networks are used for this optimal load scheduling process. For generate economic scheduling artificial neural network has been used because generation of power from each source is economically different. In this the total load required is the inputs of this network and the power generation from each source and power losses at the time of transmission are the output of the neural network. Training and programming of the artificial neural networks are done using MATLAB.

  15. Magnetoelastic Demagnetization of Steel under Cyclic Loading

    Science.gov (United States)

    Muratov, K. R.; Novikov, V. F.; Neradovskii, D. F.; Kazakov, R. Kh.

    2018-01-01

    Magnetoelastic demagnetization of steel samples under cyclic tensile loads has been analyzed. It has been established that values of residual magnetization that correspond to peak loads are characterized by the power-law dependence on the number of loading cycles. In some cases, in the region of high loads, the qualitative transition to exponential dependence has been observed. Coefficients of the power-law approximation of peak magnetization depend on the value of amplitude load and have specific characteristics in the vicinity of characteristic loads. The ratios of approximated slide load coefficients depending on the load are common for the three considered samples, and there is an outburst in the vicinity of the fatigue limit, which can be used as the basis for developing the rapid nondestructive method for determination of this limit.

  16. Behaviour of eggshell membranes at tensile loading

    Czech Academy of Sciences Publication Activity Database

    Strnková, M.J.; Nedomová, Š.; Trnka, Jan; Buchar, J.; Kumbár, V.

    46 B, December (2014), s. 44-48 ISSN 0324-1130 Institutional support: RVO:61388998 Keywords : eggshell membrane * tensile loading * loading rate * stress * strain strength Subject RIV: GM - Food Processing Impact factor: 0.201, year: 2014

  17. Acid loading test (pH)

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003615.htm Acid loading test (pH) To use the sharing features on this page, please enable JavaScript. The acid loading test (pH) measures the ability of the ...

  18. 1994 Pacific Northwest Loads and Resources Study.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-12-01

    The 1994 Pacific Northwest Loads and Resources Study presented herein establishes a picture of how the agency is positioned today in its loads and resources balance. It is a snapshot of expected resource operation, contractual obligations, and rights. This study does not attempt to present or analyze future conservation or generation resource scenarios. What it does provide are base case assumptions from which scenarios encompassing a wide range of uncertainties about BPA`s future may be evaluated. The Loads and Resources Study is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the 1993 Pacific Northwest Loads and Resources Study, published in December 1993. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The Federal system and regional analyses for medium load forecast are presented.

  19. Uniaxial Compressive Strength and Fracture Mode of Lake Ice at Moderate Strain Rates Based on a Digital Speckle Correlation Method for Deformation Measurement

    Directory of Open Access Journals (Sweden)

    Jijian Lian

    2017-05-01

    Full Text Available Better understanding of the complex mechanical properties of ice is the foundation to predict the ice fail process and avoid potential ice threats. In the present study, uniaxial compressive strength and fracture mode of natural lake ice are investigated over moderate strain-rate range of 0.4–10 s−1 at −5 °C and −10 °C. The digital speckle correlation method (DSCM is used for deformation measurement through constructing artificial speckle on ice sample surface in advance, and two dynamic load cells are employed to measure the dynamic load for monitoring the equilibrium of two ends’ forces under high-speed loading. The relationships between uniaxial compressive strength and strain-rate, temperature, loading direction, and air porosity are investigated, and the fracture mode of ice at moderate rates is also discussed. The experimental results show that there exists a significant difference between true strain-rate and nominal strain-rate derived from actuator displacement under dynamic loading conditions. Over the employed strain-rate range, the dynamic uniaxial compressive strength of lake ice shows positive strain-rate sensitivity and decreases with increasing temperature. Ice obtains greater strength values when it is with lower air porosity and loaded vertically. The fracture mode of ice seems to be a combination of splitting failure and crushing failure.

  20. Plug Load Behavioral Change Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  1. The Relationship Between Training Load and Injury, Illness and Soreness: A Systematic and Literature Review.

    Science.gov (United States)

    Drew, Michael K; Finch, Caroline F

    2016-06-01

    Clinically it is understood that rapid increases in training loads expose an athlete to an increased risk of injury; however, there are no systematic reviews to qualify this statement. The aim of this systematic review was to determine training and competition loads, and the relationship between injury, illness and soreness. The MEDLINE, SPORTDiscus, CINAHL and EMBASE databases were searched using a predefined search strategy. Studies were included if they analysed the relationship between training or competition loads and injury or illness, and were published prior to October 2015. Participants were athletes of any age or level of competition. The quality of the studies included in the review was evaluated using the Newcastle-Ottawa Scale (NOS). The level of evidence was defined as strong, 'consistent findings among multiple high-quality randomised controlled trials (RCTs)'; moderate, 'consistent findings among multiple low-quality RCTs and/or non-randomised controlled trials (CCTs) and/or one high-quality RCT'; limited, 'one low-quality RCT and/or CCTs, conflicting evidence'; conflicting, 'inconsistent findings among multiple trials (RCTs and/or CCTs)'; or no evidence, 'no RCTs or CCTs'. A total of 799 studies were identified; 23 studies met the inclusion criteria, and a further 12 studies that were not identified in the search but met the inclusion criteria were subsequently added to the review. The largest number of studies evaluated the relationship between injuries and training load in rugby league players (n = 9) followed by cricket (n = 5), football (n = 3), Australian Football (n = 3), rugby union (n = 2),volleyball (n = 2), baseball (n = 2), water polo (n = 1), rowing (n = 1), basketball (n = 1), swimming (n = 1), middle-distance runners (n = 1) and various sports combined (n = 1). Moderate evidence for a significant relationship was observed between training loads and injury incidence in the majority of studies (n = 27, 93

  2. Assembly procedure for Shot Loading Platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Shot Loading Platform. The Shot Loading Platform is used by multiple equipment removal projects to load shielding shot in the annular spaces of the equipment storage containers. The platform height is adjustable to accommodate different sizes of storage containers and transport assemblies

  3. Timber joints under long-term loading

    DEFF Research Database (Denmark)

    Feldborg, T.; Johansen, M.

    This report describes tests and results from stiffness and strength testing of splice joints under long-term loading. During two years of loading the spicimens were exposed to cyclically changing relative humidity. After the loading period the specimens were short-term tested. The connectors were...

  4. Monopod bucket foundations under cyclic lateral loading

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo

    on bucket foundations under lateral cyclic loading. The test setup is described in detail and a comprehensive experimental campaign is presented. The foundation is subjected to cyclic overturning moment, cyclic horizontal loading and constant vertical loading, acting on the same plane for thousands...

  5. Load balancing in integrated optical wireless networks

    DEFF Research Database (Denmark)

    Yan, Ying; Dittmann, Lars; Wong, S-W.

    2010-01-01

    In this paper, we tackle the load balancing problem in Integrated Optical Wireless Networks, where cell breathing technique is used to solve congestion by changing the coverage area of a fully loaded cell tower. Our objective is to design a load balancing mechanism which works closely with the in...

  6. Response of Rubble Foundation to Dynamic Loading

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Ibsen, Lars Bo

    1993-01-01

    The soil beneath vertical monolithic structures is subjected to a combination of static load due to the submerged weight of the structure and stochastic non-stationary loads as a result of the wave loads on the vertical wall. The stress conditions in the soil below a foundation exposed to both...

  7. Response of Rubble Foundation to Dynamic Loading

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Ibsen, Lars Bo

    1994-01-01

    The soil beneath vertical monolithic structures is subjected to a combination of static load due to the submerged weight of the structure and stochastic non-stationary loads as a result of the wave loads on the vertical wall. The stress conditions in the soil below a foundation exposed to both...

  8. Local Dynamic Stability Associated with Load Carrying

    Directory of Open Access Journals (Sweden)

    Jian Liu

    2013-03-01

    Conclusion: Current study confirmed the sensitivity of local dynamic stability measure in load carrying situation. It was concluded that load carrying tasks were associated with declined local dynamic stability, which may result in increased risk of fall accident. This finding has implications in preventing fall accidents associated with occupational load carrying.

  9. Plutonium Immobilization Can Loading Preliminary Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Kriikku, E.

    1998-11-25

    This report discusses the Plutonium Immobilization can loading preliminary equipment specifications and includes a process block diagram, process description, equipment list, preliminary equipment specifications, plan and elevation sketches, and some commercial catalogs. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas.

  10. Determining large deflections in rectangular combined loaded ...

    Indian Academy of Sciences (India)

    Abstract. In this study, large deflection of cantilever beams of Ludwick type material subjected to a combined loading consisting of a uniformly distributed load and one vertical concentrated load at the free end was investigated. In calcula- tions, both material and geometrical non-linearity have been considered. Horizon-.

  11. Load Bearing Equipment for Bone and Muscle

    Science.gov (United States)

    Shackelford, Linda; Griffith, Bryan

    2015-01-01

    Resistance exercise on ISS has proven effective in maintaining bone mineral density and muscle mass. Exploration missions require exercise with similar high loads using equipment with less mass and volume and greater safety and reliability than resistance exercise equipment used on ISS (iRED, ARED, FWED). Load Bearing Equipment (LBE) uses each exercising person to create and control the load to the partner.

  12. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  13. Auditory feedback improves heart rate moderation during moderate-intensity exercise.

    Science.gov (United States)

    Shaykevich, Alex; Grove, J Robert; Jackson, Ben; Landers, Grant J; Dimmock, James

    2015-05-01

    The objective of this study is to determine whether exposure to automated HR feedback can produce improvements in the ability to regulate HR during moderate-intensity exercise and to evaluate the persistence of these improvements after feedback is removed. Twenty healthy adults performed 10 indoor exercise sessions on cycle ergometers over 5 wk after a twice-weekly schedule. During these sessions (FB), participants received auditory feedback designed to maintain HR within a personalized, moderate-intensity training zone between 70% and 80% of estimated maximum HR. All feedback was delivered via a custom mobile software application. Participants underwent an initial assessment (PREFB) to measure their ability to maintain exercise intensity defined by the training zone without use of feedback. After completing the feedback training, participants performed three additional assessments identical to PREFB at 1 wk (POST1), 2 wk (POST2), and 4 wk (POST3) after their last feedback session. Time in zone (TIZ), defined as the ratio of the time spent within the training zone divided by the overall time of exercise, rate of perceived exertion, instrumental attitudes, and affective attitudes were then evaluated to assess results using two-way, mixed-model ANOVA with sessions and gender as factors. Training with feedback significantly improved TIZ (P exercise in healthy adults.

  14. Critical loads - assessment of uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Barkman, A.

    1998-10-01

    The effects of data uncertainty in applications of the critical loads concept were investigated on different spatial resolutions in Sweden and northern Czech Republic. Critical loads of acidity (CL) were calculated for Sweden using the biogeochemical model PROFILE. Three methods with different structural complexity were used to estimate the adverse effects of S0{sub 2} concentrations in northern Czech Republic. Data uncertainties in the calculated critical loads/levels and exceedances (EX) were assessed using Monte Carlo simulations. Uncertainties within cumulative distribution functions (CDF) were aggregated by accounting for the overlap between site specific confidence intervals. Aggregation of data uncertainties within CDFs resulted in lower CL and higher EX best estimates in comparison with percentiles represented by individual sites. Data uncertainties were consequently found to advocate larger deposition reductions to achieve non-exceedance based on low critical loads estimates on 150 x 150 km resolution. Input data were found to impair the level of differentiation between geographical units at all investigated resolutions. Aggregation of data uncertainty within CDFs involved more constrained confidence intervals for a given percentile. Differentiation as well as identification of grid cells on 150 x 150 km resolution subjected to EX was generally improved. Calculation of the probability of EX was shown to preserve the possibility to differentiate between geographical units. Re-aggregation of the 95%-ile EX on 50 x 50 km resolution generally increased the confidence interval for each percentile. Significant relationships were found between forest decline and the three methods addressing risks induced by S0{sub 2} concentrations. Modifying S0{sub 2} concentrations by accounting for the length of the vegetation period was found to constitute the most useful trade-off between structural complexity, data availability and effects of data uncertainty. Data

  15. Automated fuel pin loading system

    Science.gov (United States)

    Christiansen, D.W.; Brown, W.F.; Steffen, J.M.

    An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inerted as a batch prior to welding of end caps by one of two disclosed welding systems.

  16. 1993 Pacific Northwest Loads and Resources Study.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-12-01

    The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

  17. Solid methane cold moderator for the IBR-2 reactor

    International Nuclear Information System (INIS)

    Beliakov, A. A.; Tretiakov, I. T.; Shabalin, E. P.; Golikov, V. V.; Luschivkov, V I.

    1997-09-01

    The paper describes the research and design work carried out since 1986 at the Frank Laboratory of Neutron Physics of the Joint Institute for Nuclear Research in Dubna to create a cryogenic moderator for the IBR-22 reactor using solid methane as a moderating substance.

  18. Moderate deviations principles for the kernel estimator of ...

    African Journals Online (AJOL)

    Abstract. The aim of this paper is to provide pointwise and uniform moderate deviations principles for the kernel estimator of a nonrandom regression function. Moreover, we give an application of these moderate deviations principles to the construction of condence regions for the regression function. Resume. L'objectif de ...

  19. A discourse on moderation as a philosophical concept | Airoboman ...

    African Journals Online (AJOL)

    This work is a contemporary attempt to revivify interest in the ancient philosophical concept of moderation. It attempts a conceptual analysis of the concept of moderation as virtue. It examined this concept hand in hand with sensual desire and holds that appetites and passions need not be eradicated completely, but instead, ...

  20. Dispositional and Situational Autonomy as Moderators of Mood and Creativity

    Science.gov (United States)

    Xiao, Fengqiu; Wang, Ling; Chen, Yinghe; Zheng, Zhiwei; Chen, Wenjun

    2015-01-01

    Although previous research suggests that mood can influence creativity, the controversy about the effects of positive and negative moods has raged for years. This study investigated how the relationship between induced mood and creativity is moderated by dispositional and situational autonomy. It contrasted the different moderating effects of the…

  1. Moderate Muslims and Islamist Terrorism: Between Denial and Resistance

    Directory of Open Access Journals (Sweden)

    Alex P. Schmid

    2017-08-01

    Full Text Available Since President Trump attempted to ban Muslims from certain countries from entering the United States, the question which Muslims are ‘moderate Muslims’ and which are potential ‘radical Islamist terrorists’ has gained new relevance. While some Muslim leaders deny any connection between their religion and terrorism, it is undeniable that many terrorists claim to act in the name of Islam. This Research Paper first seeks to determine where the world’s 1.6 billion Muslims stand in relation to terrorism, distinguishing between Jihadist Muslims, Islamist Muslims, Conservative Muslims and Pluralist Muslims. It then looks at which criteria would allow us to distinguish between ‘moderates’ and other Muslims. Subsequently, the focus is on the role of moderation in Islam itself, whereby attention is given to the Global Movement of Moderates which originated in Malaysia. While some leading Muslim scholars stress that moderation is a central value in Islam, many Muslims nevertheless do not like to be called ‘moderates’ for fear of being seen as pro-Western. A further section of this Research Paper looks at how Islamist extremists view moderate Muslims. This is followed by a section that focuses on moderate Muslims voicing their opposition to Islamist terrorism – something often overlooked by Western media. The concluding section raises the thorny question whether moderation is rooted in Islam itself or comes from outside and the author pleads for humanism to be the middle ground for moderates of all faiths and political persuasions.

  2. Testing overall and moderator effects meta-regression

    NARCIS (Netherlands)

    Huizenga, H.M.; Visser, I.; Dolan, C.V.

    2011-01-01

    Random effects meta-regression is a technique to synthesize results of multiple studies. It allows for a test of an overall effect, as well as for tests of effects of study characteristics, that is, (discrete or continuous) moderator effects. We describe various procedures to test moderator effects:

  3. Towards a moderated mediation model of innovative work behaviour enhancement

    NARCIS (Netherlands)

    Stoffers, Jol M.; van der Heijden, Beatrice; Notelaers, Guy L.A.

    2014-01-01

    Purpose – The purpose of this paper is to investigate a moderated mediation model of innovative work behaviour enhancement. Perceived firm (organizational and market) performance was assumed to moderate the relationships between leader-member exchange (LMX) and organizational citizenship behaviour

  4. Addressing Moderated Mediation Hypotheses: Theory, Methods, and Prescriptions

    Science.gov (United States)

    Preacher, Kristopher J.; Rucker, Derek D.; Hayes, Andrew F.

    2007-01-01

    This article provides researchers with a guide to properly construe and conduct analyses of conditional indirect effects, commonly known as moderated mediation effects. We disentangle conflicting definitions of moderated mediation and describe approaches for estimating and testing a variety of hypotheses involving conditional indirect effects. We…

  5. Psychopathic Traits Moderate Peer Influence on Adolescent Delinquency

    Science.gov (United States)

    Kerr, Margaret; Van Zalk, Maarten; Stattin, Hakan

    2012-01-01

    Background: Peer influence on adolescent delinquency is well established, but little is known about moderators of peer influence. In this study, we examined adolescents' (targets) and their peers' psychopathic personality traits as moderators of peer influence on delinquency in peer networks. We used three separate dimensions of the psychopathic…

  6. Online load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Nielsen, Henrik Aalborg

    2013-01-01

    This paper presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. Every hour the hourly load for refrigeration for the following 42 hours is forecasted. The forecast models are time adaptive linear time-series models. The dynamic relations between the inputs and the load is modeled by simple transfer functions. The system operates in two regimes: one...

  7. Dynamic load modeling using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C.; Silva, A.P. Alves da; Torres, G. Lambert [Escola Federal de Engenharia de Itajuba, MG (Brazil). Inst. de Engenharia Eletrica

    1996-07-01

    Accurate dynamic load models allow more precise calculations of power system controls and stability limits. System identification methods can be applied to estimate load models based on measurements. Parametric and nonparametric are the two classes in system identification methods. The parametric approach has been the only one used for load modeling so far. In this paper, the performance of a nonparametric load model based on the functional polynomial artificial neural network is compared with a linear model and with the popular Zip model. The impact of clustering different load compositions is also investigated. Substation buses (138 kV) from the Brazilian system feeding important industrial consumers have been modeled. (author)

  8. Determination of thermal reactivity coefficients for the first fuel loading of MO34

    International Nuclear Information System (INIS)

    Lueley, J.; Vrban, B.; Farkas, G.; Hascik, J.; Hinca, R.; Petriska, M.; Slugen, V.

    2012-01-01

    The article introduces determination of thermal reactivity coefficients, especially summarized (isothermal) and moderator (density) reactivity coefficients between 200 grad C and 260 grad C with 2 grad C step, - in compliance with the assignment - for the first fuel loading into the RC of NP Mochovce units using 2 nd generation fuel during the start-up using calculation code MCNP5 1.60. (authors)

  9. Survival of immediately versus delayed loaded short implants: A prospective case series study

    OpenAIRE

    Alvira-Gonz?lez, Joaquin; D?az-Campos, Erick; S?nchez-Garc?s, Maria-Angeles; Gay-Escoda, Cosme

    2015-01-01

    Background To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. Material and Methods 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delaye...

  10. 14 CFR 23.511 - Ground load; unsymmetrical loads on multiple-wheel units.

    Science.gov (United States)

    2010-01-01

    ... multiple-wheel units. 23.511 Section 23.511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... CATEGORY AIRPLANES Structure Ground Loads § 23.511 Ground load; unsymmetrical loads on multiple-wheel units... distribution, to the dual wheels and tires in each dual wheel landing gear unit. (c) Deflated tire loads. For...

  11. Concurrent Working Memory Load Can Facilitate Selective Attention: Evidence for Specialized Load

    Science.gov (United States)

    Park, Soojin; Kim, Min-Shik; Chun, Marvin M.

    2007-01-01

    Load theory predicts that concurrent working memory load impairs selective attention and increases distractor interference (N. Lavie, A. Hirst, J. W. de Fockert, & E. Viding, see record 2004-17825-003). Here, the authors present new evidence that the type of concurrent working memory load determines whether load impairs selective attention or not.…

  12. APS high heat load monochromator

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach

  13. Allostatic Load and Preterm Birth

    Directory of Open Access Journals (Sweden)

    David M. Olson

    2015-12-01

    Full Text Available Preterm birth is a universal health problem that is one of the largest unmet medical needs contributing to the global burden of disease. Adding to its complexity is that there are no means to predict who is at risk when pregnancy begins or when women will actually deliver. Until these problems are addressed, there will be no interventions to reduce the risk because those who should be treated will not be known. Considerable evidence now exists that chronic life, generational or accumulated stress is a risk factor for preterm delivery in animal models and in women. This wear and tear on the body and mind is called allostatic load. This review explores the evidence that chronic stress contributes to preterm birth and other adverse pregnancy outcomes in animal and human studies. It explores how allostatic load can be used to, firstly, model stress and preterm birth in animal models and, secondly, how it can be used to develop a predictive model to assess relative risk among women in early pregnancy. Once care providers know who is in the highest risk group, interventions can be developed and applied to mitigate their risk.

  14. APS high heat load monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach.

  15. Aerosol loading impact on Asian monsoon precipitation patterns

    Science.gov (United States)

    Biondi, Riccardo; Cagnazzo, Chiara; Costabile, Francesca; Cairo, Francesco

    2017-04-01

    Solar light absorption by aerosols such as black carbon and dust assume a key role in driving the precipitation patterns in the Indian subcontinent. The aerosols stack up against the foothills of the Himalayas in the pre-monsoon season and several studies have already demonstrated that this can cause precipitation anomalies during summer. Despite its great significance in climate change studies, the link between absorbing aerosols loading and precipitation patterns remains highly uncertain. The main challenge for this kind of studies is to find consistent and reliable datasets. Several aerosol time series are available from satellite and ground based instruments and some precipitation datasets from satellite sensors, but they all have different time/spatial resolution and they use different assumptions for estimating the parameter of interest. We have used the aerosol estimations from the Ozone Monitoring Instrument (OMI), the Along-Track Scanning Radiometer (AATSR) and the MODerate resolution Imaging Spectroradiometer (MODIS) and validated them against the Aerosol Robotic Network (AERONET) measurements in the Indian area. The precipitation has been analyzed by using the Tropical Rainfall Measuring Mission (TRMM) estimations and the Modern-Era Retrospective analysis for Research and Applications version 2 (MERRA-2). From our results it is evident the discrepancy between the aerosol loading on the area of interest from the OMI, AATSR, and MODIS, but even between 3 different algorithms applied to the MODIS data. This uncertainty does not allow to clearly distinguishing high aerosol loading years from low aerosol loading years except in a couple of cases where all the estimations agree. Similar issues are also present in the precipitation estimations from TRMM and MERRA-2. However, all the aerosol datasets agree in defining couples of consecutive years with a large gradient of aerosol loading. Based on this assumption we have compared the precipitation anomalies and

  16. An Index and Test of Linear Moderated Mediation.

    Science.gov (United States)

    Hayes, Andrew F

    2015-01-01

    I describe a test of linear moderated mediation in path analysis based on an interval estimate of the parameter of a function linking the indirect effect to values of a moderator-a parameter that I call the index of moderated mediation. This test can be used for models that integrate moderation and mediation in which the relationship between the indirect effect and the moderator is estimated as linear, including many of the models described by Edwards and Lambert ( 2007 ) and Preacher, Rucker, and Hayes ( 2007 ) as well as extensions of these models to processes involving multiple mediators operating in parallel or in serial. Generalization of the method to latent variable models is straightforward. Three empirical examples describe the computation of the index and the test, and its implementation is illustrated using Mplus and the PROCESS macro for SPSS and SAS.

  17. Blended Buffet-Load-Alleviation System for Fighter Airplane

    Science.gov (United States)

    Moses, Robert W.

    2005-01-01

    The capability of modern fighter airplanes to sustain flight at high angles of attack and/or moderate angles of sideslip often results in immersion of part of such an airplane in unsteady, separated, vortical flow emanating from its forebody or wings. The flows from these surfaces become turbulent and separated during flight under these conditions. These flows contain significant levels of energy over a frequency band coincident with that of low-order structural vibration modes of wings, fins, and control surfaces. The unsteady pressures applied to these lifting surfaces as a result of the turbulent flows are commonly denoted buffet loads, and the resulting vibrations of the affected structures are known as buffeting. Prolonged exposure to buffet loads has resulted in fatigue of structures on several airplanes. Damage to airplanes caused by buffeting has led to redesigns of airplane structures and increased support costs for the United States Air Force and Navy as well as the armed forces of other countries. Time spent inspecting, repairing, and replacing structures adversely affects availability of aircraft for missions. A blend of rudder-control and piezoelectric- actuator engineering concepts was selected as a basis for the design of a vertical-tail buffet-load-alleviation system for the F/A-18 airplane. In this system, the rudder actuator is used to control the response of the first tail vibrational mode (bending at a frequency near 15 Hz), while directional patch piezoelectric actuators are used to control the second tail vibrational mode (tip torsion at a frequency near 45 Hz). This blend of two types of actuator utilizes the most effective features of each. An analytical model of the aeroservoelastic behavior of the airplane equipped with this system was validated by good agreement with measured results from a full-scale ground test, flight-test measurement of buffet response, and an in-flight commanded rudder frequency sweep. The overall performance of the

  18. Wound healing in immediately loaded implants.

    Science.gov (United States)

    Romanos, Georgios E

    2015-06-01

    The orthopedic field has accumulated ample evidence that bone formation is related to functional loading and in general to physical activity. However, despite evidence that immediately loaded implants can be predictably successful, many clinicians still use the classical (delayed loading) treatment protocol. This paper examines the effects of loading on dental implants and discusses the advantages of immediate loading. The role of loading on augmented alveolar ridges is also addressed and provides evidence that early bone resorption may be controlled when bone is functionally loaded. Similar data are emerging for advanced augmentation techniques in order to control crestal bone loss. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Effect of loading parameter on fretting fatigue

    Science.gov (United States)

    Kowser, Md. Arefin; Chowdhury, Mohammad Asaduzzaman; Shah, Quazi Md. Zobaer

    2017-06-01

    Fretting fatigue has become one of the major concern in the recent few decades since developed designs both structure's and complex engineering are facing with fatigue accompanied by friction. In this study, load factors as normal and bending forces influence on stress distribution along contact surface as well as fatigue life has been experimented by FEM analysis. Fatigue life is influenced prominently by variable fretting loads than variable tensile loadings. Maximum Von mises Stress and strain shows uniform horizontal straight line is found for maximum loading while for both type of bending, minimum loads yield the same character. It has been observed that stress distribution is more uniform for varying bending loads when variable fretting loads yield stress singularity nearer to the tip of contact between fretting pad and beam.

  20. Moderator behaviour and reactor internals integrity at Atucha I NPP

    International Nuclear Information System (INIS)

    Berra, S.; Guala, M.; Herzovich, P.; Chocron, M.; Lorenzo, A.; Raffo Calderon, Ma. C. del; Urrutia, G.

    1996-01-01

    Atucha I is a Pressure Vessel Heavy Water Cooled Heavy Water Moderator Reactor. In this kind of reactor the moderator tank is physically connected to the primary coolant. Since neutron economy requires the moderator to be as cold as possible, it is necessary that even when physically connected, it should have a separated cooling system, which in this case is also used as a feed-water preheater, and also heat mass transfer with primary coolant should be minimized. This condition requires that some reactor internals are designed in principle to last the whole life of the plant. However, in 1988 the failure of one internal produced a 16 month shut down. This incident could have been prevented but the idea that reactor internals would not have failures due to aging was dominant at that time avoiding the early detection of the failure. However, the analysis of the records after the incident showed that some process variables had changed previously to the incident, i.e., power exchanged at the moderator heat exchanger had increased. Since the station restart up some changes in the moderator process variables and a flow rate reduction of about 10% through the primary side of one moderator cooler were observed. In order to understand the flow reduction and the overall behaviour of moderators parameters, two models were developed that predict moderator and moderator cooler behavior under the new conditions. The present paper refers to these models, which together with the improvement of process variables measurements mentioned in another paper presented at this meeting permits to understand current moderator behaviour and helps to early diagnostic of an eventual reactor internal failure. (author). 2 refs, 4 figs, 1 tab

  1. A Systematic Review of Rehabilitation Exercises to Progressively Load the Gluteus Medius.

    Science.gov (United States)

    Ebert, Jay R; Edwards, Peter K; Fick, Daniel P; Janes, Gregory C

    2017-09-01

    Gluteus medius rehabilitation is of critical importance given its role in pelvic and lower limb stability, and the known link between gluteus medius weakness and many lower limb conditions. To systematically review the literature and present an evidence-based graduated series of exercises to progressively load gluteus medius. A systematic literature search was conducted in January 2016 to identify studies reporting gluteus medius muscle activity as a percentage of maximal volitional isometric contraction (MVIC), during rehabilitation exercises. Studies that investigated injury free participants were included. No restrictions were placed on the type or mode of exercise, though exercises that could not be accurately replicated or performed within an independent setting were excluded. Studies that did not normalize electromyographic activity to a side lying MVIC were excluded. Exercises were stratified based on exercise type and %MVIC: low (0% to 20%), moderate (21% to 40%), high (41% to 60%), and very high (> 61%). 20 studies were included in this review, reporting outcomes in 33 exercises (and a range of variations of the same exercise). Prone, quadruped, and bilateral bridge exercises generally produced low or moderate load. Specific hip abduction/rotation exercises were reported as moderate, high, or very high load. Unilateral stance exercises in the presence of contralateral limb movement were often high or very high load activities, while high variability existed across a range of functional weight-bearing exercises. This review outlined a series of exercises commonly employed in a rehabilitation setting, stratified based on exercise type and the magnitude of gluteus medius muscular activation. This will assist clinicians in tailoring gluteus medius loading regimens to patients, from the early postoperative through to later stages of rehabilitation.

  2. Common source-multiple load vs. separate source-individual load photovoltaic system

    Science.gov (United States)

    Appelbaum, Joseph

    1989-01-01

    A comparison of system performance is made for two possible system setups: (1) individual loads powered by separate solar cell sources; and (2) multiple loads powered by a common solar cell source. A proof for resistive loads is given that shows the advantage of a common source over a separate source photovoltaic system for a large range of loads. For identical loads, both systems perform the same.

  3. Survival of immediately versus delayed loaded short implants: A prospective case series study

    Science.gov (United States)

    Alvira-González, Joaquin; Díaz-Campos, Erick; Sánchez-Garcés, Maria-Angeles

    2015-01-01

    Background To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. Material and Methods 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. Results 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were included in the study. Twenty-eight implants were inserted following the immediate loading protocol and 26 according a two-stage procedure, depending on the torque value. The cumulative survival rate of short implants was 87% (n=54) after a mean time of 47.72 months (range 33-62 months), showing statistically significant differences related to loading protocol (p=0.047). Short implants immediately loaded had a higher long-term survival rate (96.4%) compared to the other study group (76.9%). Besides, short implants splinted to longer immediately loaded implants presented the highest survival rate (100%). Twenty-five (53.19%) short implants showed a bone loss of less than one millimeter after the follow-up period. Statistically significant differences were found between bleeding on probing, presence of plaque or suppuration and a higher bone loss in both loading protocols (p=0.001). Conclusions Immediate loading of short implants placed on free ends can be considered an option in the treatment protocol of patients with severe bone resorption especially if implants are splinted to others of greater length. Key words: Dental implants, short implants, immediate loading, prospective study, TiUnite surface. PMID:26034926

  4. Effects of morphine on respiratory load detection, load magnitude perception and tactile sensation in obstructive sleep apnea.

    Science.gov (United States)

    Tomazini Martins, Rodrigo; Carberry, Jayne C; Gandevia, Simon C; Butler, Jane E; Eckert, Danny J

    2018-04-26

    Pharyngeal and respiratory sensation is impaired in obstructive sleep apnea (OSA). Opioids may further diminish respiratory sensation. Thus, protective pharyngeal neuromuscular and arousal responses to airway occlusion that rely on respiratory sensation could be impaired with opioids to worsen OSA severity. However, little is known about the effects of opioids on upper airway and respiratory sensation in people with OSA. This study was designed to determine the effects of 40mg of MS-Contin on tactile sensation, respiratory load detection and respiratory magnitude perception in people with OSA during wakefulness. A double-blind, randomized, cross-over design (1 week wash-out) was used. 21 men with untreated OSA (apnea/hypopnea index=26{plus minus}17events/h) recruited from a larger clinical study completed the protocol. Tactile sensation using von Frey filaments on the back of the hand, internal mucosa of the cheek, uvula and posterior pharyngeal wall were not different between placebo and morphine (e.g. posterior wall=0.16[0.16,0.4]vs. 0.4[0.14,1.8]g, p=0.261). Similarly, compared to placebo, morphine did not alter respiratory load detection thresholds (nadir mask pressure detected=-2.05[-3.37,-1.55] vs. -2.19[-3.36,-1.41]cmH 2 O, p=0.767), or respiratory load magnitude perception (mean Borg scores during a 5 resistive load [range: 5-126cmH 2 O/L/s] protocol=4.5{plus minus}1.6 vs. 4.2{plus minus}1.2, p=0.347) but did reduce minute ventilation during quiet breathing (11.4{plus minus}3.3 vs. 10.7{plus minus}2.6L/min, psensation in men with mild to moderate, untreated, OSA. This suggests that altered respiratory sensation to acute mechanical stimuli is not likely to be a mechanism that contributes to worsening of OSA with a moderate dose of morphine.

  5. The Concept of Moderation Among Islamic Pious Predecessors

    Directory of Open Access Journals (Sweden)

    Shumsudin Yabi

    2014-12-01

    Full Text Available Islam is religion of simplicity, moderation, just and perfect that leads its followers to the rightful path. Moderation is an important aspect in our daily life. Prophet Muhammad praise be upon him (PBUH moderate lifestyle is a perfect exemplary. These exemplary has been adapted by previous Islamic scholars in their daily life thus they had emphasized the importance of understanding Al-Quran and Sunnah based on the understanding of previous pious predecessors. Some of the factors that had caused the digression are the diversion, misunderstanding and misinterpretation resulting to improper understanding of the concept on moderation. All these had caused misunderstanding and conflict of interests among us that had caused a disaster to the community. Results of the study found that the pious predecessors had drawn the concepts of moderations in five aspects of life. They are moderation in doing justice and goodness, doing pious deeds, in managing the economic and financial, in following the rightful path and finally moderation in leading our daily life following the exemplary of Prophet Muhammad PBUH.

  6. Acute moderate exercise improves mnemonic discrimination in young adults.

    Science.gov (United States)

    Suwabe, Kazuya; Hyodo, Kazuki; Byun, Kyeongho; Ochi, Genta; Yassa, Michael A; Soya, Hideaki

    2017-03-01

    Increasing evidence suggests that regular moderate exercise increases neurogenesis in the dentate gyrus (DG) of the hippocampus and improves memory functions in both humans and animals. The DG is known to play a role in pattern separation, which is the ability to discriminate among similar experiences, a fundamental component of episodic memory. While long-term voluntary exercise improves pattern separation, there is little evidence of alterations in DG function after an acute exercise session. Our previous studies showing acute moderate exercise-enhanced DG activation in rats, and acute moderate exercise-enhanced prefrontal activation and executive function in humans, led us to postulate that acute moderate exercise may also activate the hippocampus, including more specifically the DG, thus improving pattern separation. We thus investigated the effects of a 10-min moderate exercise (50% V̇O 2peak ) session, the recommended intensity for health promotion, on mnemonic discrimination (a behavioral index of pattern separation) in young adults. An acute bout of moderate exercise improved mnemonic discrimination performance in high similarity lures. These results support our hypothesis that acute moderate exercise improves DG-mediated pattern separation in humans, proposing a useful human acute-exercise model for analyzing the neuronal substrate underlying acute and regular exercise-enhanced episodic memory based on the hippocampus. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Moderation analysis with missing data in the predictors.

    Science.gov (United States)

    Zhang, Qian; Wang, Lijuan

    2017-12-01

    The most widely used statistical model for conducting moderation analysis is the moderated multiple regression (MMR) model. In MMR modeling, missing data could pose a challenge, mainly because the interaction term is a product of two or more variables and thus is a nonlinear function of the involved variables. In this study, we consider a simple MMR model, where the effect of the focal predictor X on the outcome Y is moderated by a moderator U. The primary interest is to find ways of estimating and testing the moderation effect with the existence of missing data in X. We mainly focus on cases when X is missing completely at random (MCAR) and missing at random (MAR). Three methods are compared: (a) Normal-distribution-based maximum likelihood estimation (NML); (b) Normal-distribution-based multiple imputation (NMI); and (c) Bayesian estimation (BE). Via simulations, we found that NML and NMI could lead to biased estimates of moderation effects under MAR missingness mechanism. The BE method outperformed NMI and NML for MMR modeling with missing data in the focal predictor, missingness depending on the moderator and/or auxiliary variables, and correctly specified distributions for the focal predictor. In addition, more robust BE methods are needed in terms of the distribution mis-specification problem of the focal predictor. An empirical example was used to illustrate the applications of the methods with a simple sensitivity analysis. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Beryllium strain under dynamic loading

    Directory of Open Access Journals (Sweden)

    Pushkov Victor

    2015-01-01

    Full Text Available There are some data (not much on dynamic characteristics of beryllium that are important, for example, when estimating construction performance at NPP emergencies. A number of data on stress-strain curves, spall strength, shear strength, fracture and structure responses of shock loaded beryllium have obtained in US and Russian laboratories. For today the model description of this complex metal behavior does not have a reasonable agreement with the experimental data, thus a wider spectrum of experimental data is required. This work presents data on dynamic compression-test diagrams of Russian beryllium. Experiments are performed using Hopkinson bar method (SHPB. Strain rates were ε ∼ 103 s−1.

  9. High voltage load resistor array

    Science.gov (United States)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  10. Bulk Modulus Capacitor Load Cells

    International Nuclear Information System (INIS)

    Dickey, C.E.

    1990-04-01

    Measurement of forces present at various locations within the SSC Model Dipole collared coil assembly is of great practical interest to development engineers. Of particular interest are the forces between coils at the parting plane and forces that exist between coils and pole pieces. It is also desired to observe these forces under the various conditions that a magnet will experience such as: during the collaring process, post-collaring, under the influence of cryogens, and during field excitation. A twenty eight thousandths of an inch thick capacitor load cell which utilizes the hydrostatic condition of a stressed plastic dielectric has been designed. These cells are currently being installed on SSC Model Dipoles. The theory, development, and application of these cells will be discussed

  11. Bulk modulus capacitor load cells

    International Nuclear Information System (INIS)

    Dickey, C.E.

    1990-01-01

    Measurement of forces present at various locations within the SSC Model Dipole collared coil assembly is of great practical interest to development engineers. Of particular interest are the forces between coils at the parting plane and forces that exist between coils and pole pieces. It is also desired to observe these forces under the various conditions that a magnet will experience such as: during the collaring process, post-collaring, under the influence of cryogens, and during field excitation. A twenty eight thousandths of an inch thick capacitor load cell which utilizes the hydrostatic condition of a stressed plastic dielectric has been designed. These cells are currently being installed on SSC Model Dipoles. The theory, development, and application of these cells will be discussed. 1 fig

  12. Impaired sleep and allostatic load

    DEFF Research Database (Denmark)

    Clark, Alice Jessie; Dich, Nadya; Lange, Theis

    2014-01-01

    Objective: Understanding the mechanisms linking sleep impairment to morbidity and mortality is important for future prevention, but these mechanisms are far from elucidated. We aimed to determine the relation between impaired sleep, both in terms of duration and disturbed sleep, and allostatic load...... Biobank with comprehensive information on sleep duration, disturbed sleep, objective measures of an extensive range of biological risk markers, and physical conditions. Results: Long sleep (mean difference 0.23; 95% confidence interval, 0.13, 0.32) and disturbed sleep (0.14; 0.06, 0.22) were associated...... with higher AL as well as with high-risk levels of risk markers from the anthropometric, metabolic, and immune system. Sub-analyses suggested that the association between disturbed sleep and AL might be explained by underlying disorders. Whereas there was no association between short sleep and AL...

  13. Greywater pollution variability and loadings

    DEFF Research Database (Denmark)

    Eriksson, Eva; Andersen, Henrik Rasmus; Madsen, Toke S.

    2009-01-01

    Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min−1....... Concentrations of both macro- and micro-pollutants (organic matter and parabens) were found to range by several orders of magnitude in the influent, based on sampling every 20 min. Paraben degradation was proven to occur in the rotating biological contactor (RBC), while the remnant organic matter in the effluent...... was proved not to be readily degradable. Ammonium content, presumably from urine contamination, was found to undergo nitrification in the RBC. Mass flow (daily loads) for individual substances was calculated for several pollutants. Macropollutants were found to be generated in low numbers of grams per person...

  14. High heat load synchrotron optics

    International Nuclear Information System (INIS)

    Mills, D.M.

    1993-01-01

    Third generation synchrotron radiation sources currently being constructed worldwide will produce x-ray beams of unparalleled power and power density. These high heat fluxes coupled with the stringent dimensional requirements of the x-ray optical components pose a prodigious challenge to designers of x-ray optical elements, specifically x-ray mirrors and crystal monochromators. Although certain established techniques for the cooling of high heat flux components can be directly applied to this problem, the thermal management of high heat load x-ray optical components has several unusual aspects that may ultimately lead to unique solutions. This manuscript attempts to summarize the various approaches currently being applied to this undertaking and to point out the areas of research that require further development

  15. Dynamic loading of galvanized parts

    Directory of Open Access Journals (Sweden)

    Michal Černý

    2010-01-01

    Full Text Available This work is divided into two parts: the theoretical part includes actual knowledge and points of view about degradation processes in construction materials, anticorrosion protection, zinc coat composition and high frequency fatigue. The laboratory part follow-up existing regulations contents Czech standards and formulate specifications for acquisition of objective information from acceleration la­bo­ra­to­ry tests in condensation chests, mechanical high frequency fatigue tests on pulsator machine and possibilities of evaluation of fatigue tests. Laboratory findings declare to fundamental types of damage of constructions with anticorrosion protection in real loading conditions with dynamic high frequency character. Laboratory tests were made in sulphide and chloride environments.

  16. Diffusion Indexes with Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    to the problem by using the LASSO as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model which is better suited for forecasting compared......The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the traditional principal components (PC) approach.We provide an asymptotic analysis of the estimator and illustrate its merits empirically in a forecasting experiment based on US macroeconomic data. Overall we find that compared to PC we obtain improvements in forecasting accuracy and thus find...

  17. Diffusion Indexes With Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    2017-01-01

    The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the problem by using the least absolute shrinkage and selection operator (LASSO) as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model...... that is better suited for forecasting compared to the traditional principal components (PC) approach. We provide an asymptotic analysis of the estimator and illustrate its merits empirically in a forecasting experiment based on U.S. macroeconomic data. Overall we find that compared to PC we obtain improvements...

  18. Tar loads on Omani beaches

    International Nuclear Information System (INIS)

    Badawy, M.I.; Al-Harthy, F.T.

    1991-01-01

    Owing to Oman's geographic position and long coastal line, the coastal areas of Oman are particularly vulnerable to oil pollution from normal tanker operations, illegal discharges, and accidental spills as well as local sources of oil input. UNEP carried out a survey on the coasts of Oman to determine the major sources of oil pollution and concluded that the major shoreline pollution problems in Oman arose from operational discharges of oil from passing vessels traffic. The oil, because of the high sea and air temperatures in the area, was subjected to relatively high rates of evaporation and photo-oxidation and tended to arrive at the coast as heavy petroleum particulate residues (tar balls). The aim of the present study was to measure the loads of tar balls in Omani coastal areas and to identify the source of oil pollutants on beaches

  19. Research on Operation and Control Strategy of 600MW PWR in Load Follow

    International Nuclear Information System (INIS)

    Qu, Bing Yang; Cao, Xin Rong; Li, Han Chen

    2014-01-01

    600MW Pressurized Water Reactor (PWR) is designed to operate in Constant Axial Offset Control (CAOC) strategy with base load originally. By calculations over a typical load follow scenario '12-3-6-3 ( 100-50-100%FP) via the CASMO-4E and SIMULATE-3 package, values of core operating parameter have been examined. With the progress of the nuclear power industry, advanced reactors are considered to have a good performance in load follow, economy and flexibility. Under the premise of fuel loading and structural dimensions unchanged, two independent control rod groups M and AO are used in 600MW pressurized water reactor to provide fine control of both the core reactivity and axial power distribution, which is named ' Improved G strategy .' The influences of different control rod distributions, composition materials, and overlap steps had in power changes have been examined in a comparative study to choose the optimal one.Then we simulate a range of load follow scenarios of the redesigned 600MW core without adjusting soluble boron concentration in the begin, middle and end of first cycle. This paper additionally demonstrated the moderator temperature coefficient and shutdown margin values of the reactor in Improved G strategy to compare with the thermal safety design criteria. It's demonstrated that adequate adjustment of control rod groups enable the core to perform load follow through Improved G strategy in 80% of cycle and save a large volume of liquid effluent particularly toward the end of cycle

  20. Enhanced water use efficiency in global terrestrial ecosystems under increasing aerosol loadings

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Xiaoliang; Chen, Min; Liu, Yaling; Miralles, Diego G.; Wang, Faming

    2017-05-01

    Aerosols play a crucial role in the climate system, affecting incoming radiation and cloud formation. Based on a modelling framework that couples ecosystem processes with the atmospheric transfer of radiation, we analyze the effect of aerosols on surface incoming radiation, gross primary productivity (GPP), water losses from ecosystems through evapotranspiration (ET) and ecosystem water use efficiency (WUE, defined as GPP/ET) for 2003–2010 and validate them at global FLUXNET sites. The total diffuse radiation increases under relatively low or intermediate aerosol loadings, but decreases under more polluted conditions. We find that aerosol-induced changes in GPP depend on leaf area index, aerosol loading and cloudiness. Specifically, low and moderate aerosol loadings cause increases in GPP for all plant types, while heavy aerosol loadings result in enhancement (decrease) in GPP for dense (sparse) vegetation. On the other hand, ET is mainly negatively affected by aerosol loadings due to the reduction in total incoming radiation. Finally, WUE shows a consistent rise in all plant types under increasing aerosol loadings. Overall, the simulated daily WUE compares well with observations at 43 eddy-covariance tower sites (R2=0.84 and RMSE=0.01gC (kg H2O)-1) with better performance at forest sites. In addition to the increasing portions of diffuse light, the rise in WUE is also favored by the reduction in radiation- and heat-stress caused by the aerosols, especially for wet and hot climates.

  1. Convergent validity of a novel method for quantifying rowing training loads.

    Science.gov (United States)

    Tran, Jacqueline; Rice, Anthony J; Main, Luana C; Gastin, Paul B

    2015-01-01

    Elite rowers complete rowing-specific and non-specific training, incorporating continuous and interval-like efforts spanning the intensity spectrum. However, established training load measures are unsuitable for use in some modes and intensities. Consequently, a new measure known as the T2minute method was created. The method quantifies load as the time spent in a range of training zones (time-in-zone), multiplied by intensity- and mode-specific weighting factors that scale the relative stress of different intensities and modes to the demands of on-water rowing. The purpose of this study was to examine the convergent validity of the T2minute method with Banister's training impulse (TRIMP), Lucia's TRIMP and Session-RPE when quantifying elite rowing training. Fourteen elite rowers (12 males, 2 females) were monitored during four weeks of routine training. Unadjusted T2minute loads (using coaches' estimates of time-in-zone) demonstrated moderate-to-strong correlations with Banister's TRIMP, Lucia's TRIMP and Session-RPE (rho: 0.58, 0.55 and 0.42, respectively). Adjusting T2minute loads by using actual time-in-zone data resulted in stronger correlations between the T2minute method and Banister's TRIMP and Lucia's TRIMP (rho: 0.85 and 0.81, respectively). The T2minute method is an appropriate in-field measure of elite rowing training loads, particularly when actual time-in-zone values are used to quantify load.

  2. Allostatic load and biological anthropology.

    Science.gov (United States)

    Edes, Ashley N; Crews, Douglas E

    2017-01-01

    Multiple stressors affect developing and adult organisms, thereby partly structuring their phenotypes. Determining how stressors influence health, well-being, and longevity in human and nonhuman primate populations are major foci within biological anthropology. Although much effort has been devoted to examining responses to multiple environmental and sociocultural stressors, no holistic metric to measure stress-related physiological dysfunction has been widely applied within biological anthropology. Researchers from disciplines outside anthropology are using allostatic load indices (ALIs) to estimate such dysregulation and examine life-long outcomes of stressor exposures, including morbidity and mortality. Following allostasis theory, allostatic load represents accumulated physiological and somatic damage secondary to stressors and senescent processes experienced over the lifespan. ALIs estimate this wear-and-tear using a composite of biomarkers representing neuroendocrine, cardiovascular, metabolic, and immune systems. Across samples, ALIs are associated significantly with multiple individual characteristics (e.g., age, sex, education, DNA variation) of interest within biological anthropology. They also predict future outcomes, including aspects of life history variation (e.g., survival, lifespan), mental and physical health, morbidity and mortality, and likely health disparities between groups, by stressor exposures, ethnicity, occupations, and degree of departure from local indigenous life ways and integration into external and commodified ones. ALIs also may be applied to similar stress-related research areas among nonhuman primates. Given the reports from multiple research endeavors, here we propose ALIs may be useful for assessing stressors, stress responses, and stress-related dysfunction, current and long-term cognitive function, health and well-being, and risk of early mortality across many research programs within biological anthropology. © 2017 American

  3. Development of a moderate rate lithium/thionyl-chloride D cell

    Science.gov (United States)

    Cieslak, Wendy R.; Street, Henry K.

    1990-05-01

    We have designed a lithium/thionyl chloride D cell for efficient performance at the moderate rate of approximately 500 mA (6.25 omega load). The SNL-MR-D cell has 345 sq cm of active electrode area, 1.0 M LiAlCl4 electrolyte that may have SO2 additive, and a cathode blended of Shawinigan Acetylene Black, Cabot Black Pearls 2000, and Teflon binder. The average performance of cells built in-house and discharged at 25 C and 6.25 omega has been 14.9 Ah (50 Wh). We have aged the cells at 30 C and 50 C, and measured complex impedance and microcalorimetry during the aging period. The cells have been discharged after the aging period at 25 C and 0 C. This preliminary study has allowed us to establish an initial cell design and estimate the rate of capacity loss on storage or long-term usage.

  4. Elasto/visco-plastic analysis of moderately thick shells of revolution

    International Nuclear Information System (INIS)

    Takezono, S.; Tanoue, M.

    1981-01-01

    The analytical formulation on the elasto-visco-plastic problems of general, moderately thick shells of revolution subjected to axisymmetrical load is developed by extension of the Reissner theory in elastic shells where a consideration on the effect of shear deformations is given. The authors employ as constitutive relation of the shell materials Perzyna's equation where in the plastic range the viscosity of the material is considered. The criterion for yielding used in this analysis is the von Mises yield theory. The basic differential equations derived for elasto-visco-plastic problems are numerically solved by a finite difference method, and the solutions are obtained by integration of the incremental values. As a numerical example, the elasto/visco-plastic deformation of pressure vessels is analyzed, and the results are compared with those from the classical theory which neglects the effect of shear deformations. (orig.)

  5. Quadricuspid Aortic Valve Combined with Moderate Ascending Aortic Dilatation

    Science.gov (United States)

    Uspenskiy, Vladimir E.; Osadchii, Alexei M.; Gordeev, Mikhail L.

    2015-01-01

    The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography. PMID:27390747

  6. Monitoring task loading with multivariate EEG measures during complex forms of human-computer interaction

    Science.gov (United States)

    Smith, M. E.; Gevins, A.; Brown, H.; Karnik, A.; Du, R.

    2001-01-01

    Electroencephalographic (EEG) recordings were made while 16 participants performed versions of a personal-computer-based flight simulation task of low, moderate, or high difficulty. As task difficulty increased, frontal midline theta EEG activity increased and alpha band activity decreased. A participant-specific function that combined multiple EEG features to create a single load index was derived from a sample of each participant's data and then applied to new test data from that participant. Index values were computed for every 4 s of task data. Across participants, mean task load index values increased systematically with increasing task difficulty and differed significantly between the different task versions. Actual or potential applications of this research include the use of multivariate EEG-based methods to monitor task loading during naturalistic computer-based work.

  7. Thermal loads on the TJ-II Vacuum Vessel under Neutral Beam Injection

    International Nuclear Information System (INIS)

    Guasp, J.; Fuentes, C.; Liniers, M.

    1996-01-01

    In this study a numerical analysis of power loads on the complex 3D structure of the TJ-II Vacuum Vessel, moderated with reasonable accuracy, under NBI, is done. To do this it has been necessary to modify deeply the DENSB code for power loads in order to include the TJ-II VV wall parts as targets and as beam scrapers, allowing the possibility of self-shadowing. After a short description of the primitive version of the DENSB code (paragraph 2) and of the visualisation code MOVIE(paragraph 3), the DENSB upgrading are described (paragraphs 4,5) and finally the results are presented (paragraph 6). These code modifications and the improving on the visualization tools provide more realistic load evaluations, both with and without plasma, validating former results and showing clearly the VV zones that will need new protections. (Author)

  8. Efficient loading of primary alcohols onto a solid phase using a trityl bromide linker

    DEFF Research Database (Denmark)

    Crestey, François; Ottesen, Lars Korsgaard; Jaroszewski, Jerzy Witold

    2008-01-01

    expensive or non-commercial resin types. Secondary alcohols were only attached in moderate to low yields, while attempts to load a tertiary alcohol expectedly failed. Importantly, selective attachment of diols via a primary alcohol group in the presence of more hindered alcohol groups proved possible......The Letter describes an improved, rapid and mild strategy for the loading of primary alcohols onto a polystyrene trityl resin via a highly reactive trityl bromide linker. This protocol facilitates an efficient resin loading even of acid-sensitive or heat-labile alcohols, which otherwise require....... The effects of activation time and reagent excess as well as alcohol structure were investigated. This improved method provides a convenient access to O-linked resin-bound N-Fmoc-protected amino alcohols that may be employed in SPS of peptides with C-terminal alcohol functionalities. In the case...

  9. Model of wind shear conditional on turbulence and its impact on wind turbine loads

    DEFF Research Database (Denmark)

    Dimitrov, Nikolay Krasimirov; Natarajan, Anand; Kelly, Mark C.

    2015-01-01

    fatigue load is achieved. The proposed wind shear model based on the wind measurements is thereby probabilistic in definition, with shear jointly distributed with wind turbulence. A simplified model for the wind shear exponent is further derived from the full stochastic model. The fatigue loads over......We analyse high-frequency wind velocity measurements from two test stations over a period of several years and at heights ranging from 60 to 200 m, with the objective to validate wind shear predictions as used in load simulations for wind turbine design. A validated wind shear model is thereby...... different turbine components are evaluated under the full wind measurements, using the developed wind shear model and with standard wind conditions prescribed in the IEC 61400-1 ed. 3. The results display the effect of the Wöhler exponent and reveal that under moderate turbulence, the effect of wind shear...

  10. Neutron moderation at very low temperatures (1691); Moderation des neutrons aux tres basses temperatures (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Lacaze, A. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-04-15

    Starting from Harwell experiment carried out inside a low-power reactor, we intended to maintain a liquid hydrogen cell in a channel of the EL3 reactor (at Saclay) whose thermal neutrons flux is 10{sup 14} neutrons/cm{sup 2}/s. We tried to work out a device giving off an important beam of cold neutrons and able to operate in a way as automatic as possible during many consecutive day without a stop. Several circuits have already been achieved at very low temperatures but they brought out volumes and fluxes much lower than those we used this time. The difficulties we have met in carrying out such a device arose on the one hand from the very high energy release to which any kind of experiment is inevitably submitted when placed near the core of the reactor, on the other, hand from the very little room which is available in experimental channels of reactors. In such condition, it is necessary to use a moderator as effective as possible. This study is divided into three parts ; in the first part, we try to determine: a) conditions in which moderation takes place, hence the volume of the cell; b) materials likely to be used at low temperature and in pile; c) cooling system; hence we had to study fluid flow conditions at very low temperatures in very long ducts. The second part is devoted to the description of the device. The third part ventilates the results we have obtained. (author) [French] Partant de l'experience de Harwell faite dans une pile de faible puissance, nous nous sommes propose de maintenir une cellule d'hydrogene liquide dans un canal de la pile EL3 de Saclay dont le flux de neutrons thermiques est de 10{sup 14} neutrons par seconde et par cm{sup 2}. Nous avons cherche a realiser une installation donnant un faisceau de neutrons froids important, et pouvant fonctionner d'une maniere aussi automatique que possible, pendant des periodes de plusieurs jours sans arret. Plusieurs circuits aux tres basses temperatures ont deja ete realises, mais

  11. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  12. Static Load Distribution in Ball Bearings

    Science.gov (United States)

    Ricci, Mario

    2010-01-01

    A numerical procedure for computing the internal loading distribution in statically loaded, single-row, angular-contact ball bearings when subjected to a known combined radial and thrust load is presented. The combined radial and thrust load must be applied in order to avoid tilting between inner and outer rings. The numerical procedure requires the iterative solution of Z + 2 simultaneous nonlinear equations - where Z is the number of the balls - to yield an exact solution for axial and radial deflections, and contact angles. Numerical results for a 218 angular-contact ball bearing have been compared with those from the literature and show significant differences in the magnitudes of the ball loads, contact angles, and the extent of the loading zone.

  13. On-load refuelling for power reactors

    International Nuclear Information System (INIS)

    Smith, D.R.

    1987-01-01

    The problems of handling irradiated fuel are, first that there is a residual heat produced even when the fission process in the fuel element is ended by shutdown or withdrawal of the fuel element from the reactor on-load. Secondly, that highly penetrating ionising radiations are emitted from irradiated fuel. In PWR and BWR reactors the need for on-load fuel handling has been avoided. However, in other types on-load handling became part of the design. The conditions needed for on-load handling and some of the problems with on-load handling of magnox fuel elements are mentioned. The situation for CANDU and other reactor types are considered briefly. The detailed design of machines for on-load fuel handling for the UK gas-cooled reactors and typical refuelling machines in current use are described in some detail. (UK)

  14. Multi-Capacity Load Cell Concept

    Directory of Open Access Journals (Sweden)

    Seif. M. OSMAN

    2014-09-01

    Full Text Available Force measuring systems are usually used to calibrate force generated systems, it is not preferable to use load cells to measure forces less than 10 % of its nominal capacity. Several load cells are required to offer calibration facilities at sites to cover different ranges, this lead to difficulties in handling procedures, through the need for several carrying cases to carry this overweight in addition to the over cost of purchasing several load cells. This article concerns with introducing a new concept for designing a multi-capacity load cell as a new force standard in the field of measuring the force. This multi-capacity load cell will replace a set of load cells and reflects economically on the total cost and on easiness of handling procedures.

  15. [Environment load from China's cement production].

    Science.gov (United States)

    Zhu, Tian-le; He, Wei; Zeng, Xiao-lan; Huang, Xin; Ma, Bao-guo

    2006-10-01

    Based on the life-cycle theory, a quantitative evaluation of the environment load caused by cement manufacturing in China was carried out with the application of the CML. environmental impact assessment method. The results show that global warming potential, energy depletion potential and abiotic depletion potential make the main contribution to the environment impact, their environmental loads corresponding to identical environmental impact sorts being 2.76%, 2.34% and 1.39% of the overall load of the whole world, respectively. In 2004, the environment load from cement manufacturing in China is roughly 1.28% of the overall load of the whole world, in which the environmental loads from the shaft kiln processing, wet rotary processing and new-type dry processing being 0.84%, 0.12% and 0.32%, respectively. And it can be reduced to about 1% by replacing backward production processes with the dry method production process.

  16. Drug loaded biodegradable load-bearing nanocomposites for damaged bone repair

    Science.gov (United States)

    Gutmanas, E. Y.; Gotman, I.; Sharipova, A.; Psakhie, S. G.; Swain, S. K.; Unger, R.

    2017-09-01

    In this paper we present a short review-scientific report on processing and properties, including in vitro degradation, of load bearing biodegradable nanocomposites as well as of macroporous 3D scaffolds for bone ingrowth. Biodegradable implantable devices should slowly degrade over time and disappear with ingrown of natural bone replacing the synthetic graft. Compared to low strength biodegradable polymers, and brittle CaP ceramics, biodegradable CaP-polymer and CaP-metal nanocomposites, mimicking structure of natural bone, as well as strong and ductile metal nanocomposites can provide to implantable devices both strengths and toughness. Nanostructuring of biodegradable β-TCP (tricalcium phosphate)-polymer (PCL and PLA), β-TCP-metal (FeMg and FeAg) and of Fe-Ag composites was achieved employing high energy attrition milling of powder blends. Nanocomposite powders were consolidated to densities close to theoretical by high pressure consolidation at ambient temperature—cold sintering, with retention of nanoscale structure. The strength of developed nanocomposites was significantly higher as compared with microscale composites of the same or similar composition. Heat treatment at moderate temperatures in hydrogen flow resulted in retention of nanoscale structure and higher ductility. Degradation of developed biodegradable β-TCP-polymer, β-TCP-metal and of Fe-Ag nanocomposites was studied in physiological solutions. Immersion tests in Ringer's and saline solution for 4 weeks resulted in 4 to 10% weight loss and less than 50% decrease in compression or bending strength, the remaining strength being significantly higher than the values reported for other biodegradable materials. Nanostructuring of Fe-Ag based materials resulted also in an increase of degradation rate because of creation on galvanic Fe-Ag nanocouples. In cell culture experiments, the developed nanocomposites supported the attachment the human osteoblast cells and exhibited no signs of cytotoxicity

  17. Adaptive Load Balancing Strategy Based on LVS

    OpenAIRE

    Fu Chen; Zhang Li-Jun

    2017-01-01

    Linux Virtual Server (LVS) is a load balancing server that deployed on a cluster of real servers and the load balancer running on the Linux operating system. In the scheduling module, we designed an adaptive load balancing strategy. Firstly, we introduce the traffic state prediction. The algorithm we choose is Radial Basis Function (RBF) neural network. Secondly, we update weights according to the real-time usage of CPU, memory and hard disk. Then we conduct a series of experiments and the ad...

  18. Deterministic chaos in the processor load

    International Nuclear Information System (INIS)

    Halbiniak, Zbigniew; Jozwiak, Ireneusz J.

    2007-01-01

    In this article we present the results of research whose purpose was to identify the phenomenon of deterministic chaos in the processor load. We analysed the time series of the processor load during efficiency tests of database software. Our research was done on a Sparc Alpha processor working on the UNIX Sun Solaris 5.7 operating system. The conducted analyses proved the presence of the deterministic chaos phenomenon in the processor load in this particular case

  19. Assessment of wind turbine load measurement instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Morfiadakis, E.; Papadopoulos, K. [CRES (Greece); Borg, N. van der [ECN, Petten (Netherlands); Petersen, S.M. [Risoe, Roskilde (Denmark); Seifert, H. [DEWI, Wilhelmshaven (Germany)

    1999-03-01

    In the framework of Sub-Task3 `Wind turbine load measurement instrumentation` of EU-project `European Wind Turbine Testing Procedure Development`, the load measurement techniques have been assessed by laboratory, full scale and numerical tests. The existing methods have been reviewed with emphasis on the strain gage application techniques on composite materials and recommendations are provided for the optimisation of load measurement techniques. (au) EU. 14 refs.

  20. NORMAL LOAD BEARING BY SITE SPECIFIC CANISTER

    Energy Technology Data Exchange (ETDEWEB)

    NA

    2005-03-23

    The overall purpose of this calculation is to perform a preliminary analysis of the Site Specific Canister/Basket, subject to static gravity loads that include the self weight of the Canister Shell, the Basket, the Spent Nuclear Fuel, the Shield Plug and the related hardware, so that the loads are approximately known for sizing purposes. Based on these loads the stress levels in various components of the Site Specific Canister/Basket are evaluated.

  1. Fatigue durability under random cyclic loading

    Science.gov (United States)

    Volkov, S. S.; Struzhanov, V. V.

    2017-12-01

    Methods for predicting the durability of metals have been developed while taking into account the effect of random loads acting during the service life of structures. Methods of the theory of functions of random variables are applied. Normal distribution and the Rayleigh distribution are used to estimate the random loads from the experimental histogram. A numerical example illustrates the influence of the statistical parameters of the load distribution on the predicted number of cycles before failure.

  2. Automatic Multimodal Cognitive Load Measurement (AMCLM)

    Science.gov (United States)

    2011-06-01

    increasing, while F2 is decreasing, as cognitive load is increased. Classification results performed on the Stroop test database show that formant...Final Project Report Grant AOARD-10-4029 Automatic Multimodal Cognitive Load Measurement (AMCLM) June 2011 NICTA DSIM Team...past year. At the start of the project, we carried out a literature review on video based physiological measures of cognitive load, focusing on

  3. 1991 Pacific Northwest Loads and Resources Study.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1991-12-01

    This study establishes the Bonneville Power Administration's (BPA) planning basis for supplying electricity to BPA customers. The Loads and Resources Study is presented in three documents: (1) this summary of federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates our 1990 study. BPS's long-range planning incorporates resource availability with a range of forecasted electrical consumption. The forecasted future electrical demands-firm loads--are subtracted from the projected capability of existing resources to determine whether BPA and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, then additional conservation, contract purchases, or generating resources will be needed to meet load growth. This study analyzes the Pacific Northwest's projected loads and available generating resources in two parts: (1) the loads and resources of the federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional profile, which includes loads and resources in addition to the federal system. This study presents the federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for 1992- 2012.

  4. A no-load RF calorimeter

    Science.gov (United States)

    Chernoff, R. C.

    1975-01-01

    The described device can be used to measure the output of any dc powered RF source. No dummy load is required for the measurements. The device is, therefore, called the 'no-load calorimeter' (NLC). The NLC measures the power actually fed to the antenna or another useful load. It is believed that the NLC can compete successfully with directional coupler type systems in measuring the output of high-power RF sources.

  5. A randomized comparative trial of two low-dose oral isotretinoin regimens in moderate to severe acne vulgaris

    Science.gov (United States)

    Dhaked, Daulat Ram; Meena, Ram Singh; Maheshwari, Anshul; Agarwal, Uma Shankar; Purohit, Saroj

    2016-01-01

    Background: Oral isotretinoin is highly effective in all forms and grades of acne, even in lower dosages (acne vulgaris. Materials and Methods: A total of 240 patients with moderate to severe acne vulgaris were selected and randomized into two groups and treated with a fixed dose of 20 mg of isotretinoin (Group A - daily and Group B - alternate days) for 24 weeks and followed up for 12 weeks post therapy. Results: A total of 234 patients completed the study. At the end of therapy, decrease in the total acne loads up to 98.99% (Group A) and 97.69% (Group B) was achieved from the baseline (P acne, Group A performed significantly better than Group B until the end of 36 weeks. While in the moderate acne, significant difference in the response between both groups was observed only up to 12 weeks. No serious side effect was observed. Conclusion: Both isotretinoin regimens were well tolerated and found to be an effective treatment for moderate to severe acne vulgaris. However, in moderate acne 20 mg alternate day regimen may be preferred. A 20 mg daily regimen is a better choice for severe acne in terms of response. Limitation: Small sample size and short follow-up period. PMID:27730033

  6. Hemodynamic responses to mental stress during salt loading.

    Science.gov (United States)

    Gefke, Maria; Christensen, Niels Juel; Bech, Per; Frandsen, Erik; Damgaard, Morten; Asmar, Ali; Norsk, Peter

    2017-11-01

    The purpose was to examine whether prolonged moderate stress associated with a student exam would increase the blood pressure response to a salt load in young healthy normotensive individuals. Ten healthy young subjects were examined at two different occasions in random order (i) during preparation for a medical exam (prolonged stress) and (ii) outside the exam period (low stress). All subjects consumed a controlled diet for 3 days with low- or high-salt content in randomized order. The subjective stress was measured by Spielberger's State-Trait Anxiety Inventory-Scale, SCL Symptom Checklist for stress and the Visual Analogue Scale. On each level of stress, 24-h ambulatory blood pressure and cardiac output (CO) were measured. Furthermore, plasma norepinephrine (NE), epinephrine (E) and plasma renin activity (PRA) were measured. Twenty-four-hour ABP, 24-h heart rate, CO as well as plasma levels of NE, E and PRA remained unchanged by changes in stress level. Day-night reduction in SAP was significantly larger during moderate stress and high-salt intake; however, no significant difference was observed during daytime and night-time. Individual increase in mental stress correlated significantly with an individual decrease in PRA (SCL-17, r = -0·80, Pstress over a period of time in young healthy normotensive individuals does not lead to changes in 24-h ABP. However, the augmented reduction in day-to-night systolic blood pressure during high-salt intake and moderate stress may indicate that stress affects blood pressure regulation. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  7. Age and leadership : The moderating role of legacy beliefs

    NARCIS (Netherlands)

    Zacher, Hannes; Rosing, Kathrin; Frese, Michael

    Age and age-related motivations have been neglected in leadership research. This study examined the moderating influence of legacy beliefs on the relationships between age and transformational, transactional, and passive-avoidant leadership behaviors. Legacy beliefs involve individuals' convictions

  8. The moderating role of human values in planned behavior

    DEFF Research Database (Denmark)

    Zhou, Y.; Thøgersen, John; Ruan, Y.

    2013-01-01

    Purpose – This article aims to study the role of personal values as moderators of the antecedents of consumers’ “green” buying intentions in the context of Chinese consumers’ inclination to buy organic food. Design/methodology/approach – Ordinary Chinese consumers (n ¼ 479) were intercepted...... and filled out a questionnaire outside upscale supermarkets in Guangzhou. Multigroup structural equation modeling was used to test hypotheses about personal values’ moderating effect in the theory of planned behavior. Findings – Self-transcendence values moderate the relationship between two antecedents...... contribute positively to the development of the economy. Originality/value – This article extends the rare literature analyzing Chinese consumers’ inclination to buy organic food. It also extends the understanding of the role of personal values as moderators of antecedents of consumers’ buying intentions...

  9. On the neutron slowing-down in moderators

    Energy Technology Data Exchange (ETDEWEB)

    Caldeira, Alexandre D., E-mail: alexdc@ieav.cta.br [Instituto de Estudos Avançados (IEAV), São José dos Campos, SP (Brazil). Divisão de Energia Nuclear

    2017-07-01

    Neutron slowing-down is a very important subject to be considered in several areas of nuclear energy application, such as thermal nuclear reactors, nuclear medicine, radiological protection, detectors design and so on. Moderator materials are the responsible to perform this task and among the neutron induced cross sections, the elastic scattering cross section is the main nuclear interaction in this case. At thermal neutron energies, the moderator molecular or crystalline structure become important and dependent on the moderator phase, gas, liquid, or solid, its cross sections and, consequently, the angular and energy distributions of the scattered neutron are affected. The procedures used for generating correctly moderators cross sections at thermal neutron energies from evaluated nuclear data files utilizing the NJOY system are addressed. (author)

  10. Youth Exposed to Terrorism: the Moderating Role of Ideology.

    Science.gov (United States)

    Slone, Michelle; Shur, Lia; Gilady, Ayelet

    2016-05-01

    The present review examines the moderating role of ideology on the effects of war, armed conflict, and terrorism on youth. Ideology is an important factor given the central role played by religio-political ideology and nationalism in present-day conflicts. Ideologies or worldviews represent cognitive frameworks that imbue the traumatic situation with meaning and order. Analysis of the pool of studies identified three categories of ideologically based moderating factors, each representing an aspect of social construction of traumatic events, namely, religion, political ideology, and self-concept. The two closely related categories of religion and politico-religious beliefs showed both positive and negative effects on psychological and psychiatric outcomes among youth. The third category of different aspects of self-concept yielded consistently positive moderating effects. The mechanisms by which each category of ideology moderates effects of exposure to war, armed conflict, and terrorism are discussed, and research and clinical implications are presented.

  11. St. John Benthic Habitat Mapping - Moderate Depth Ground Validation Sites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic habitats of the moderate-depth marine environment in and around the Virgin Islands Coral Reef National Monument were mapped using a combination of...

  12. Moderator clean-up system in a heavy water reactor

    International Nuclear Information System (INIS)

    Sasada, Yasuhiro; Hamamura, Kenji.

    1983-01-01

    Purpose: To decrease the fluctuation of the poison concentration in heavy water moderator due to a heavy water clean-up system. Constitution: To a calandria tank filled with heavy water as poison-containing moderators, are connected both end of a pipeway through which heavy water flows and to which a clean-up device is provided. Strongly basic resin is filled within the clean-up device and a cooler is disposed to a pipeway at the upstream of the clean-up device. In this structure, the temperature of heavy water at the inlet of the clean-up device at a constant level between the temperature at the exit of the cooler and the lowest temperature for the moderator to thereby decrease the fluctuation in the poison concentration in the heavy water moderator due to the heavy water clean-up device. (Moriyama, K.)

  13. Demographic Data - MDC_LowModerateBlockGroup

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — A polygon feature class of Miami-Dade Low-Moderate Block Groups also referred to as Community Development Block Group (CDBG). Identify only those census block groups...

  14. Gadolinium-loaded gel scintillators for neutron and antineutrino detection

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Catherine Lynn; Akers, Douglas William; Demmer, Ricky Lynn; Paviet, Patricia Denise; Drigert, Mark William

    2016-11-29

    A gadolinium (Gd) loaded scintillation gel (Gd-ScintGel) compound allows for neutron and gamma-ray detection. The unique gel scintillator encompasses some of the best features of both liquid and solid scintillators, yet without many of the disadvantages associated therewith. Preferably, the gel scintillator is a water soluble Gd-DTPA compound and water soluble fluorophores such as: CdSe/ZnS (or ZnS) quantum dot (Q-dot) nanoparticles, coumarin derivatives 7-hydroxy-4-methylcoumarin, 7-hydroxy-4-methylcoumarin-3-acetic acid, 7-hydroxycoumarin-3-carboxylic acid, and Alexa Fluor 350 as well as a carbostyril compound, carbostyril 124 in a stable water-based gel, such as methylcellulose or polyacrylamide polymers. The Gd-loaded ScintGel allows for a homogenious distribution of the Gd-DTPA and the fluorophores, and yields clean fluorescent emission peaks. A moderator, such as deuterium or a water-based clear polymer, can be incorporated in the Gd-ScintGel. The gel scintillators can be used in compact detectors, including neutron and antineutrino detectors.

  15. Load prediction of stall regulated wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Bjoerck, A.; Dahlberg, J.Aa. [Aeronautical Research Inst. of Sweden, Bromma (Sweden); Carlen, I. [Chalmers Univ. of Technology, Goeteborg (Sweden). Div. of Marine Structural Engineering; Ganander, H. [Teknikgruppen AB, Sollentua (Sweden)

    1996-12-01

    Measurements of blade loads on a turbine situated in a small wind farm shows that the highest blade loads occur during operation close to the peak power i.e. when the turbine operates in the stall region. In this study the extensive experimental data base has been utilised to compare loads in selected campaigns with corresponding load predictions. The predictions are based on time domain simulations of the wind turbine structure, performed by the aeroelastic code VIDYN. In the calculations a model were adopted in order to include the effects of dynamic stall. This paper describes the work carried out so far within the project and key results. 5 refs, 10 figs

  16. Comparison of Temperature Loadings of Bridge Girders

    Directory of Open Access Journals (Sweden)

    J. Římal

    2008-01-01

    Full Text Available This paper compares the effect of temperature changes on the superstructure of bridges, above all the effect of non-uniform temperature. Loadings according to standards ESN 73 6203, ENV 1991-1-5 and DIN 1072 are compared here. The paper shows a short summary of temperature loading according to each standard and shows the comparison of bending moments arisen from these temperature loadings on superstructure made from continuous girder from a steel-concrete box girder with a composite concrete slab. With respect to a variety of design processes, the comparison is made without any coefficient of loading, combination or material. 

  17. Adaptive Load Balancing Strategy Based on LVS

    Directory of Open Access Journals (Sweden)

    Fu Chen

    2017-01-01

    Full Text Available Linux Virtual Server (LVS is a load balancing server that deployed on a cluster of real servers and the load balancer running on the Linux operating system. In the scheduling module, we designed an adaptive load balancing strategy. Firstly, we introduce the traffic state prediction. The algorithm we choose is Radial Basis Function (RBF neural network. Secondly, we update weights according to the real-time usage of CPU, memory and hard disk. Then we conduct a series of experiments and the adaptive strategies have a better performance on load balancing.

  18. Wheelchair caster loading during frontal impact.

    Science.gov (United States)

    Bertocci, Gina E; van Roosmalen, Linda

    2003-01-01

    Many wheelchair users are required or choose to use their wheelchairs as a motor vehicle seat during transport. It is therefore key that the wheelchair components be designed to tolerate crash-level loading conditions. Casters are particularly prone to failure under crash loading conditions. Our study evaluated wheelchair caster loading during 20g/48 kph frontal sled impact testing using an 85-kg surrogate wheelchair base (SWCB) with casters positioned on a load-measuring platform. A Hybrid III 50th percentile male test dummy was seated in the SWCB, which simulated a power wheelchair and was secured using four-point tiedowns. Various rear securement point heights and wheelchair seating systems were used to study their effect on caster loading. Caster normal loading was found to vary from 769 to 7,209 N depending on rear securement location and integrity of the seating system. Dynamic sled impact test results showed that normal loading of the front wheelchair casters was influenced by wheelchair seating system integrity and rear wheelchair securement height. Shear loading varied from 781 to 1,589 N and did not appear to be dependent on seat integrity or rear securement height. The load/time histories measured during dynamic impact testing can be used to guide the development of transit-safe caster design.

  19. Working memory load modulates microsaccadic rate.

    Science.gov (United States)

    Dalmaso, Mario; Castelli, Luigi; Scatturin, Pietro; Galfano, Giovanni

    2017-03-01

    Microsaccades are tiny eye movements that individuals perform unconsciously during fixation. Despite that the nature and the functions of microsaccades are still lively debated, recent evidence has shown an association between these micro eye movements and higher order cognitive processes. Here, in two experiments, we specifically focused on working memory and addressed whether differential memory load could be reflected in a modulation of microsaccade dynamics. In Experiment 1, participants memorized a numerical sequence composed of either two (low-load condition) or five digits (high-load condition), appearing at fixation. The results showed a reduction in the microsaccadic rate in the high-load compared to the low-load condition. In Experiment 2, five red or green digits were always presented at fixation. Participants either memorized the color (low-load condition) or the five digits (high-load condition). Hence, visual stimuli were exactly the same in both conditions. Consistent with Experiment 1, microsaccadic rate was lower in the high-load than in the low-load condition. Overall, these findings reveal that an engagement of working memory can have an impact on microsaccadic rate, consistent with the view that microsaccade generation is pervious to top-down processes.

  20. Economic impact analysis of load forecasting

    International Nuclear Information System (INIS)

    Ranaweera, D.K.; Karady, G.G.; Farmer, R.G.

    1997-01-01

    Short term load forecasting is an essential function in electric power system operations and planning. Forecasts are needed for a variety of utility activities such as generation scheduling, scheduling of fuel purchases, maintenance scheduling and security analysis. Depending on power system characteristics, significant forecasting errors can lead to either excessively conservative scheduling or very marginal scheduling. Either can induce heavy economic penalties. This paper examines the economic impact of inaccurate load forecasts. Monte Carlo simulations were used to study the effect of different load forecasting accuracy. Investigations into the effect of improving the daily peak load forecasts, effect of different seasons of the year and effect of utilization factors are presented

  1. Behaviour of Cohesionless Soils During Cyclic Loading

    DEFF Research Database (Denmark)

    Shajarati, Amir; Sørensen, Kris Wessel; Nielsen, Søren Kjær

    Offshore wind turbine foundations are typically subjected to cyclic loading from both wind and waves, which can lead to unacceptable deformations in the soil. However, no generally accepted standardised method is currently available, when accounting for cyclic loading during the design of offshore...... wind turbine foundations. Therefore a literature study is performed in order to investigate existing research treating the behaviour of cohesionless soils, when subjected to cyclic loading. The behaviour of a soil subjected to cyclic loading is found to be dependent on; the relative density, mean...

  2. Plutonium Immobilization Can Loading Conceptual Design

    International Nuclear Information System (INIS)

    Kriikku, E.

    1999-01-01

    'The Plutonium Immobilization Facility will encapsulate plutonium in ceramic pucks and seal the pucks inside welded cans. Remote equipment will place these cans in magazines and the magazines in a Defense Waste Processing Facility (DWPF) canister. The DWPF will fill the canister with glass for permanent storage. This report discusses the Plutonium Immobilization can loading conceptual design and includes a process block diagram, process description, preliminary equipment specifications, and several can loading issues. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas.'

  3. Improved Load Shedding Scheme considering Distributed Generation

    DEFF Research Database (Denmark)

    Das, Kaushik; Nitsas, Antonios; Altin, Müfit

    2017-01-01

    . These schemes utilize directional relays, power flow through feeders, wind and PV measurements to optimally select the feeders to be disconnected during load shedding such that DG disconnection is minimized while disconnecting required amount of consumption. These different UFLS schemes are compared in terms......With high penetration of distributed generation (DG), the conventional under-frequency load shedding (UFLS) face many challenges and may not perform as expected. This article proposes new UFLS schemes, which are designed to overcome the shortcomings of traditional load shedding scheme...... of frequency response, amount of consumption and DG disconnected during load shedding....

  4. Load Extrapolation During Operation for Wind Turbines

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2008-01-01

    In the recent years load extrapolation for wind turbines has been widely considered in the wind turbine industry. Loads on wind turbines during operations are normally dependent on the mean wind speed, the turbulence intensity and the type and settings of the control system. All these parameters...... must be taken into account when characteristic load effects during operation are determined. In the wind turbine standard IEC 61400-1 a method for load extrapolation using the peak over threshold method is recommended. In this paper this method is considered and some of the assumptions are examined...

  5. Atropine Pharmacokinetics are Affected by Moderate Hemorrhage and Hypothyroidism

    Science.gov (United States)

    1989-12-01

    Moderate Hemorrhage and Hypothyroidism 12. PERSONAL AUTHOR(S) R.C. Smallridge, B. Chernow, S. Teich, C. Kinzer, C. Umstott, G. Geelhoed, _ Ppmnl i n 13a...moderate hemorrhage and hypothyroidism ROBERT C. SMALLRIDGE, MD: BART CHERNOW, MD: STEVEN TEICH, MD, CAROL KINZER: CAROLYN UMSTOTT: GLEN GEELHOED. MD...under resting conditions. logic responses (heart rate, mydriasis, inhibition of Pharmacokinetic studies were performed in mongrel logi reo (a rat . dogs

  6. Management preferences of pediatricians in moderate and severe acute asthma.

    Science.gov (United States)

    Arga, Mustafa; Bakirtas, Arzu; Catal, Ferhat; Derinoz, Oksan; Topal, Erdem; Demirsoy, M Sadik; Turktas, Ipek

    2013-05-01

    To assess and compare management preferences of physicians for moderate and severe acute asthma based on case scenarios and to determine the factors influencing their decisions. A questionnaire based on the Global Initiative on Asthma (GINA) guideline and comprising eight questions on management of acute asthma was delivered to participants of two national pediatric congresses. Management of moderate and severe acute asthma cases was evaluated by two clinical case scenarios for estimation of acute attack severity, initial treatment, treatment after 1h, and discharge recommendations. A uniform answer box comprising the possible choices was provided just below the questions, and respondents were requested to tick the answers they thought was appropriate. Four-hundred and eighteen questionnaires were analyzed. All questions regarding moderate and severe acute asthma case scenarios were answered accurately by 15.8% and 17.0% of physicians, respectively. The initial treatment of moderate and severe cases was known by 100.0% and 78.2% of physicians, respectively. Knowledge of the appropriate plan for treatment after 1h was low both for moderate (45.0%) and severe attacks (35.4%). Discharge recommendations were adequate in 32.5% and 70.8% of physicians for moderate and severe attacks, respectively. Multiple logistic regression analysis revealed that working at a hospital with a continuing medical education program was the only significant predictor of a correct response to all questions regarding severe attacks (p = .04; 95%CI, 1.02-3.21). No predictors were found for information on moderate attacks. Pediatricians have difficulty in planning treatment after 1 hour both for moderate and severe asthma attacks. Postgraduate education programs that target physicians in hospitals without continuing medical education facilities may improve guideline adherence.

  7. Double Moderated Mediation Models: Problems and (Part) Remedies

    OpenAIRE

    Chryssochoidis, George

    2018-01-01

    Purpose: Researchers in management regularly face modelling issues that involve double moderated mediation models. Here, we illustrate how to conceptualise, specify and empirically estimate mediation effects when having to simultaneously account for continuous (Likert type) and nominal (i.e., group) moderator variables. Researchers’ estimates of the mediation effects suffer serious bias due to the effects of unaccounted confounders. This is an issue that plagues management research and this w...

  8. Nutritional Supplementation of Children with Moderate Acute Malnutrition

    DEFF Research Database (Denmark)

    Fabiansen, Christian

    Background Moderate acute malnutrition (MAM), defined as moderate wasting or low mid-upper arm circumference (MUAC), is widespread among children in low-income countries. Children with MAM are at immediate risk of mortality and morbidity or deterioration into severe acute malnutrition. Children...... presented in this thesis may have immediate relevance for malnutrition programs. First, it is recommended to use LNS supplements in children with MAM. Secondly, it is recommended to admit children

  9. Pulsed neutron source cold moderators --- concepts, design and engineering

    International Nuclear Information System (INIS)

    Bauer, Guenter S.

    1997-01-01

    Moderator design for pulsed neutron sources is becoming more and more an interface area between source designers and instrument designers. Although there exists a high degree of flexibility, there are also physical and technical limitations. This paper aims at pointing out these limitations and examining ways to extend the current state of moderator technology in order to make the next generation neutron sources even more versatile and flexible tools for science in accordance with the users' requirements. (auth)

  10. Moderate deviations for some point measures in geometric probability

    Science.gov (United States)

    Baryshnikov, Yu; Eichelsbacher, P.; Schreiber, T.; Yukich, J. E.

    2008-06-01

    Functionals in geometric probability are often expressed as sums of bounded functions exhibiting exponential stabilization. Methods based on cumulant techniques and exponential modifications of measures show that such functionals satisfy moderate deviation principles. This leads to moderate deviation principles and laws of the iterated logarithm for random packing models as well as for statistics associated with germ-grain models and $k$ nearest neighbor graphs.

  11. A core-monitoring based methodology for predictions of graphite weight loss in AGR moderator bricks

    International Nuclear Information System (INIS)

    McNally, K.; Warren, N.; Fahad, M.; Hall, G.; Marsden, B.J.

    2017-01-01

    Highlights: • A statistically-based methodology for estimating graphite density is presented. • Graphite shrinkage is accounted for using a finite element model. • Differences in weight loss forecasts were found when compared to the existing model. - Abstract: Physically based models, resolved using the finite element (FE) method are often used to model changes in dimensions and the associated stress fields of graphite moderator bricks within a reactor. These models require inputs that describe the loading conditions (temperature, fluence and weight loss ‘field variables’), and coded relationships describing the behaviour of graphite under these conditions. The weight loss field variables are calculated using a reactor chemistry/physics code FEAT DIFFUSE. In this work the authors consider an alternative data source of weight loss: that from a longitudinal dataset of density measurements made on small samples trepanned from operating reactors during statutory outages. A nonlinear mixed-effect model is presented for modelling the age and depth-related trends in density. A correction that accounts for irradiation-induced dimensional changes (axial and radial shrinkage) is subsequently applied. The authors compare weight loss forecasts made using FEAT DIFFUSE with those based on an alternative statistical model for a layer four moderator brick for the Hinkley Point B, Reactor 3. The authors compare the two approaches for the weight loss distribution through the brick with a particular focus on the interstitial keyway, and for the average (over the volume of the brick) weight loss.

  12. A numerical study of internal brick stresses in AGR moderator bricks

    International Nuclear Information System (INIS)

    McNally, K.; Fahad, M.; Tan, E.; Warren, N.; Hall, G.N.; Marsden, B.J.

    2016-01-01

    Highlights: • A methodology for studying the uncertainty in internal brick stresses was developed. • A computationally efficient methodology based upon a surrogate model was utilised. • Uncertainty in material relationships, particularly those related to secondary creep was the dominant source of uncertainty. - Abstract: Physically-based models are often used to model changes in geometry and the associated stress fields of graphite moderator bricks within an advanced gas-cooled reactor (AGR). These models require inputs that describe the loading conditions, and coded relationships describing the behaviour of material properties. Material relationships are primarily based upon data obtained from inspection campaigns at operating reactors. However, the data from trepanning campaigns do not provide information on some of the key relationships and parameters that affect the internal stresses generated within the moderator bricks. In this work we explore how uncertain material property relationships affect the internal brick stresses in early- and late-life. We describe two computer experiments designed to study early- and late-life brick stresses and report the results from global sensitivity analysis of the models. The work makes use of an emulator, a surrogate for the FE model, in order to make the sensitivity analyses computationally feasible.

  13. Effect of Acute Exposure to Moderate Altitude on Muscle Power: Hypobaric Hypoxia vs. Normobaric Hypoxia

    Science.gov (United States)

    Feriche, Belén; García-Ramos, Amador; Calderón-Soto, Carmen; Drobnic, Franchek; Bonitch- Góngora, Juan G.; Galilea, Pedro A.; Riera, Joan; Padial, Paulino

    2014-01-01

    When ascending to a higher altitude, changes in air density and oxygen levels affect the way in which explosive actions are executed. This study was designed to compare the effects of acute exposure to real or simulated moderate hypoxia on the dynamics of the force-velocity relationship observed in bench press exercise. Twenty-eight combat sports athletes were assigned to two groups and assessed on two separate occasions: G1 (n = 17) in conditions of normoxia (N1) and hypobaric hypoxia (HH) and G2 (n = 11) in conditions of normoxia (N2) and normobaric hypoxia (NH). Individual and complete force-velocity relationships in bench press were determined on each assessment day. For each exercise repetition, we obtained the mean and peak velocity and power shown by the athletes. Maximum power (Pmax) was recorded as the highest Pmean obtained across the complete force-velocity curve. Our findings indicate a significantly higher absolute load linked to Pmax (∼3%) and maximal strength (1RM) (∼6%) in G1 attributable to the climb to altitude (Pbarbell displacement velocity (P<0.001). No changes in any of the variables examined were observed in G2. According to these data, we can state that acute exposure to natural moderate altitude as opposed to simulated normobaric hypoxia leads to gains in 1RM, movement velocity and power during the execution of a force-velocity curve in bench press. PMID:25474104

  14. Moderate Imaging Resolution Spectroradiometer (MODIS) Aerosol Optical Depth Retrieval for Aerosol Radiative Forcing

    Science.gov (United States)

    Asmat, A.; Jalal, K. A.; Ahmad, N.

    2018-02-01

    The present study uses the Aerosol Optical Depth (AOD) retrieved from Moderate Imaging Resolution Spectroradiometer (MODIS) data for the period from January 2011 until December 2015 over an urban area in Kuching, Sarawak. The results show the minimum AOD value retrieved from MODIS is -0.06 and the maximum value is 6.0. High aerosol loading with high AOD value observed during dry seasons and low AOD monitored during wet seasons. Multi plane regression technique used to retrieve AOD from MODIS (AODMODIS) and different statistics parameter is proposed by using relative absolute error for accuracy assessment in spatial and temporal averaging approach. The AODMODIS then compared with AOD derived from Aerosol Robotic Network (AERONET) Sunphotometer (AODAERONET) and the results shows high correlation coefficient (R2) for AODMODIS and AODAERONET with 0.93. AODMODIS used as an input parameters into Santa Barbara Discrete Ordinate Radiative Transfer (SBDART) model to estimate urban radiative forcing at Kuching. The observed hourly averaged for urban radiative forcing is -0.12 Wm-2 for top of atmosphere (TOA), -2.13 Wm-2 at the surface and 2.00 Wm-2 in the atmosphere. There is a moderate relationship observed between urban radiative forcing calculated using SBDART and AERONET which are 0.75 at the surface, 0.65 at TOA and 0.56 in atmosphere. Overall, variation in AOD tends to cause large bias in the estimated urban radiative forcing.

  15. 24 CFR 3280.401 - Structural load tests.

    Science.gov (United States)

    2010-04-01

    ... yielding. Design live load deflection criteria do not apply when the structural assembly being evaluated... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead...

  16. The case for moderate-risk buyers: An empirical investigation.

    Science.gov (United States)

    Jung, Joowon; Yi, Sunghwan

    2016-06-30

    Despite recent increase in research on compulsive buying and excessive buying, the category of buyers whose buying patterns are approaching the clinical level but still somewhat below it has rarely been recognized in the literature. In this paper, we propose the case for the category of moderate-risk buyers. Following Ridgway et al.'s (2008) findings, moderate-risk buyers were operationalized as scoring 21-24 on Compulsive Buying Index. We hypothesized that moderate-risk buyers would hold significantly higher materialistic values than non-compulsive buyers, while exhibiting significantly less depressive symptoms and covert narcissism than full-fledged compulsive buyers. An online survey of individuals who frequently engaged in buying lapses was used (N=809). We found that moderate-risk buyers were significantly different from both compulsive buyers and non-compulsive buyers in the frequency of buying lapses, hiding purchases and frequency of experiencing negative feelings leading to buying lapses. Furthermore, consistent with our hypothesis, moderate-risk buyers held significantly lower covert narcissism and depression than full-fledged compulsive buyers, but their materialism was not significantly different from each other. Our findings support the case for moderate-risk buyers as a separate group from full-fledged compulsive buyers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Thermal-hydraulic experiments and analyses on cold moderator

    International Nuclear Information System (INIS)

    Aso, Tomokazu; Kaminaga, Masanori; Terada, Atsushi; Hino, Ryutaro

    2001-01-01

    A cold moderator using supercritical hydrogen is one of the key components in a MW-scale spallation target system, which directly affects the neutronic performance both in intensity and resolution. Since a hydrogen temperature rise in the moderator vessel affects the neutronic performance, it is necessary to suppress the local temperature rise within 3 K. In order to develop the conceptual design of the moderator structure in progress, the flow patterns were measured using a PIV (Particle Image Velocimeter) system under water flow conditions using a flat model that simulated a moderator vessel. From these results, the flow patterns (such as recirculation flows, stagnant flows etc.) were clarified. The hydraulic analytical results obtained using the STAR-CD code agreed well with experimental results. Thermal-hydraulic analyses in the moderator vessel were carried out using the STAR-CD code. Based on these results, we clarified the possibility of suppressing the local temperature rise to within 3 K under 2 MW operating conditions. In order to achieve the cost decreasing of the hydrogen loop, it is necessary to operate it reducing the hydrogen flow rate and the whole hydrogen mass. Then improved moderator concept using blowholes and a twisted tape was proposed, and we have tried to examine the effect of the blowing flow from the inlet pipe. From the experimental and analytical results, the blowing flow could be feasible for the suppression of the stagnant region. (author)

  18. System and method employing a self-organizing map load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

    2014-06-17

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

  19. Survival of immediately versus delayed loaded short implants: A prospective case series study.

    Science.gov (United States)

    Alvira-González, Joaquin; Díaz-Campos, Erick; Sánchez-Garcés, Maria-Angeles; Gay-Escoda, Cosme

    2015-07-01

    To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were included in the study. Twenty-eight implants were inserted following the immediate loading protocol and 26 according a two-stage procedure, depending on the torque value. The cumulative survival rate of short implants was 87% (n=54) after a mean time of 47.72 months (range 33-62 months), showing statistically significant differences related to loading protocol (p=0.047). Short implants immediately loaded had a higher long-term survival rate (96.4%) compared to the other study group (76.9%). Besides, short implants splinted to longer immediately loaded implants presented the highest survival rate (100%). Twenty-five (53.19%) short implants showed a bone loss of less than one millimeter after the follow-up period. Statistically significant differences were found between bleeding on probing, presence of plaque or suppuration and a higher bone loss in both loading protocols (p=0.001). Immediate loading of short implants placed on free ends can be considered an option in the treatment protocol of patients with severe bone resorption especially if implants are splinted to others of greater length.

  20. Knee loading protects against osteonecrosis of the femoral head by enhancing vessel remodeling and bone healing.

    Science.gov (United States)

    Liu, Daquan; Li, Xinle; Li, Jie; Yang, Jing; Yokota, Hiroki; Zhang, Ping

    2015-12-01

    Osteonecrosis of the femoral head is a serious orthopedic problem. Moderate loads with knee loading promote bone formation, but their effects on osteonecrosis have not been investigated. Using a rat model, we examined a hypothesis that knee loading enhances vessel remodeling and bone healing through the modulation of the fate of bone marrow-derived cells. In this study, osteonecrosis was induced by transecting the ligamentum teres followed by a tight ligature around the femoral neck. For knee loading, 5 N loads were laterally applied to the knee at 15 Hz for 5 min/day for 5 weeks. Changes in bone mineral density (BMD) and bone mineral content (BMC) of the femur were measured by pDEXA, and ink infusion was performed to evaluate vessel remodeling. Femoral heads were harvested for histomorphometry, and bone marrow-derived cells were isolated to examine osteoclast development and osteoblast differentiation. The results showed that osteonecrosis significantly induced bone loss, and knee loading stimulated both vessel remodeling and bone healing. The osteonecrosis group exhibited the lowest trabecular BV/TV (p b 0.001) in the femoral head, and lowest femoral BMD and BMC (both p b 0.01). However, knee loading increased trabecular BV/TV (p b 0.05) as well as BMD (pb 0.05) and BMC (p b 0.01). Osteonecrosis decreased the vessel volume (pb 0.001), vessel number (pb 0.001) and VEGF expression (p b 0.01), and knee loading increased them (pb 0.001, pb 0.001 and p b 0.01). Osteonecrosis activated osteoclast development, and knee loading reduced its formation, migration, adhesion and the level of “pit” formation (pb 0.001, pb 0.01, pb 0.001 and pb 0.001). Furthermore, knee loading significantly increased osteoblast differentiation and CFU-F (both p b 0.001). A significantly positive correlation was observed between vessel remodeling and bone healing (both p b 0.01). These results indicate that knee loading could be effective in repair osteonecrosis of the femoral head in a rat

  1. Measuring training load in sports.

    Science.gov (United States)

    Lambert, Michael Ian; Borresen, Jill

    2010-09-01

    The principle of training can be reduced to a simple "dose-response" relationship. The "response" in this relationship can be measured as a change in performance or the adaptation of a physiological system. The "dose" of training, or physiological stress associated with the training load, is more difficult to measure as there is no absolute "gold standard" which can be used in the field, making it difficult to validate procedures. Attempts have been made to use heart rate as a marker of intensity during training, but the theoretical attractiveness of this method is not supported by the accuracy and the practicality of using this method during training or competition. The session RPE, based on the product of training duration and perceived intensity is more practical and can be used in a variety of sports. However, the score depends on a subjective assessment, and the intersubject comparisons may be inaccurate. The demands of different sports vary and therefore the methods of assessing training need to vary accordingly. The time has come to reach consensus on assessing training accurately in different sports. There is a precedent for this consensus approach with scientists having already done so for the assessment of physical activity, and for defining injuries in rugby, football and cricket. Standardizing these methods has resulted in the quality of research in these areas increasing exponentially.

  2. Graphite-moderated and heavy water-moderated spectral shift controlled reactors; Reactores de moderador solido controlados por desplazamiento espectral

    Energy Technology Data Exchange (ETDEWEB)

    Alcala Ruiz, F.

    1984-07-01

    It has been studied the physical mechanisms related with the spectral shift control method and their general positive effects on economical and non-proliferant aspects (extension of the fuel cycle length and low proliferation index). This methods has been extended to non-hydrogenous fuel cells of high moderator/fuel ratio: heavy water cells have been con- trolled by graphite rods graphite-moderated and gas-cooled cells have been controlled by berylium rods and graphite-moderated and water-cooled cells have been controlled by a changing mixture of heavy and light water. It has been carried out neutron and thermal analysis on a pre design of these types of fuel cells. We have studied its neutron optimization and their fuel cycles, temperature coefficients and proliferation indices. Finally, we have carried out a comparative analysis of the fuel cycles of conventionally controlled PWRs and graphite-moderated, water-cooled and spectral shift controlled reactors. (Author) 71 refs.

  3. Only minor additional metabolic health benefits of high as opposed to moderate dose physical exercise in young, moderately overweight men

    DEFF Research Database (Denmark)

    Reichkendler, M H; Larsen, Mads Rosenkilde; Auerbach, P L

    2014-01-01

    % in HIGH (P benefits were found when exercising ∼3,800 as opposed to ∼2,000 kcal/week in young moderately overweight men. This finding may have important......OBJECTIVE: The dose-response effects of exercise training on insulin sensitivity, metabolic risk, and quality of life were examined. METHODS: Sixty-one healthy, sedentary (VO₂max: 35 ± 5 ml/kg/min), moderately overweight (BMI: 27.9 ± 1.8), young (age: 29 ± 6 years) men were randomized to sedentary...... living (sedentary control group; n = 18), moderate (moderate dose training group [MOD]: 300 kcal/day, n = 21), or high (high dose training group [HIGH]: 600 kcal/day, n = 22) dose physical exercise for 11 weeks. RESULTS: The return rate for post-intervention testing was 82-94% across groups. Weekly...

  4. Behaviour of glass plates under wind loads

    Science.gov (United States)

    Gavanski, Eri

    Glazing damage during strong windstorms has been considered to result mainly from windborne debris. However, recent windstorm damage reports have revealed the necessity of studying fluctuating wind loads, which appear to be another factor contributing to this damage. From an experimental point of view, studies on this topic have been limited to the application of rather simple loading patterns. Moreover, there is an uncertainty surrounding both load resistance and design load used in the current North American window glass design codes. It is of concern that these regulations may not offer sufficient accuracy on account of the limited understanding of time-dependent glass strength derived from the technology available at the time of codification. Unprecedented full-scale glass breakage tests under realistic wind pressure loading were conducted to investigate these issues. The obtained results revealed significant new information about the behavior of glass plates under fluctuating loads. Along with these tests, a numerical simulation using the Monte-Carlo technique was also performed with a subtle modification of the initial glass strength. This adjustment resulted in better correspondence with test results. Using the test and numerical simulation results, the current window glass design method was examined. The calculation methods of LR, and the reference time conversion used in the codes, were found to require further investigation. By creating a particular wind pressure time history, the practice of using peak pressures from ASCE7-05 as the design load was investigated. The results showed that there are cases when the current practice may underestimate the design load because of the duration of windstorms. KEYWORDS: Glass, Fluctuating load, Full-scale test, Load resistance, Design load, Static fatigue, Numerical simulation, Monte-Carlo technique, Brown's integral.

  5. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  6. The friction coefficient of shoulder joints remains remarkably low over 24 h of loading.

    Science.gov (United States)

    Jones, Brian K; Durney, Krista M; Hung, Clark T; Ateshian, Gerard A

    2015-11-05

    The frictional response of whole human joints over durations spanning activities of daily living has not been reported previously. This study measured the friction of human glenohumeral joints during 24 h of reciprocal loading in a pendulum testing device, at moderate (0.2 mm/s, 4320 cycles) and low (0.02 mm/s, 432 cycles) sliding speeds, under a 200 N load. The effect of joint congruence was also investigated by testing human humeral heads against significantly larger mature bovine glenoids. Eight human joints and six bovine joints were tested in four combinations: human joints tested at moderate (hHCMS, n=6) and low speed (hHCLS, n=3), human humeral heads tested against bovine glenoids at moderate speed (LCMS, n=3), and bovine joints tested at moderate speed (bHCMS, n=3). In the first half hour the mean±standard deviation of the friction coefficient was hHCMS: 0.0016±0.0011, hHCLS: 0.0012±0.0002, LCMS: 0.0008±0.0002 and bHCMS: 0.0024±0.0008; in the last four hours it was hHCMS: 0.0057±0.0025, hHCLS: 0.0047±0.0017, LCMS: 0.0012±0.0003 and bHCMS: 0.0056±0.0016. The initial value was lower than the final value (pfriction coefficient of natural human shoulders remains remarkably low (averaging as little as 0.0015 and no greater than 0.006) for up to 24 h of continuous loading. The sustained low friction coefficients observed in incongruent joints (~0.001) likely represent rolling rather than sliding friction. Copyright © 2015. Published by Elsevier Ltd.

  7. The Friction Coefficient of Shoulder Joints Remains Remarkably Low Over 24 h of Loading

    Science.gov (United States)

    Jones, Brian K.; Durney, Krista M.; Hung, Clark T.; Ateshian, Gerard A.

    2015-01-01

    The frictional response of whole human joints over durations spanning activities of daily living has not been reported previously. This study measured the friction of human glenohumeral joints during 24 h of reciprocal loading in a pendulum testing device, at moderate (0.2 mm/s, 4320 cycles) and low (0.02 mm/s, 432 cycles) sliding speeds, under a 200 N load. The effect of joint congruence was also investigated by testing human humeral heads against significantly larger mature bovine glenoids. Six human joints and six bovine joints were tested in four combinations: human joints tested at moderate (hHCMS, n=6) and low speed (hHCLS, n=3), human humeral heads tested against bovine glenoids at moderate speed (LCMS, n=3), and bovine joints tested at moderate speed (bHCMS, n=3). In the first half hour the mean ± standard deviation of the friction coefficient was hHCMS: 0.0016±0.0011, hHCLS: 0.0012±0.0002, LCMS: 0.0008±0.0002 and bHCMS: 0.0024±0.0008; in the last four hours it was hHCMS: 0.0057±0.0025, hHCLS: 0.0047±0.0017, LCMS: 0.0012±0.0003 and bHCMS: 0.0056±0.0016. The initial value was lower than the final value (pfriction coefficient of natural human shoulders remains remarkably low (averaging as little as 0.0015 and no greater than 0.006) for up to 24 h of continuous loading. The sustained low friction coefficients observed in incongruent joints (~0.001) likely represent rolling rather than sliding friction. PMID:26472306

  8. Live load testing and load rating of five reinforced concrete bridges.

    Science.gov (United States)

    2014-10-01

    Five cast-in-place concrete T-beam bridges Eustis #5341, Whitefield #3831, Cambridge #3291, Eddington #5107, : and Albion #2832 were live load tested. Revised load ratings were computed either using test data or detailed : analysis when possi...

  9. Demonstration of load rating capabilities through physical load testing : Sioux County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  10. Demonstration of load rating capabilities through physical load testing : Johnson County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  11. Demonstration of load rating capabilities through physical load testing : Ida County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  12. Variability of load and net load in case of large scale distributed wind power

    OpenAIRE

    Holttinen, Hannele; Kiviluoma, J.; Estanqueiro, Ana; Gómez-Lázaro, E.; Raw, Barry; Dobschinski, Jan; Meibon, Peter; Lannoye, Eamonn; Aigner, Tobias; Wan, Yih H.; Milligan, Michael

    2011-01-01

    Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates),number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the...

  13. Variability of load and net load in case of large scale distributed wind power

    OpenAIRE

    Holttinen, Hannele; Kiviluoma, Juha; Estanqueiro, Ana; Aigner, Tobias; Wan, Yih-Huei; Milligan, Michael R.

    2010-01-01

    Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net loa...

  14. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Torcellini, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  15. Using Bench Press Load to Predict Upper Body Exercise Loads in Physically Active Individuals

    Science.gov (United States)

    Wong, Del P.; Ngo, Kwan-Lung; Tse, Michael A.; Smith, Andrew W.

    2013-01-01

    This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m-2) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key points The bench press load was significantly correlated with the loads of the 4 assistance exercises. No significant differences were found between the actual load and the predicted load in the four equations. 6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises. PMID:24149723

  16. Load power device and system for real-time execution of hierarchical load identification algorithms

    Science.gov (United States)

    Yang, Yi; Madane, Mayura Arun; Zambare, Prachi Suresh

    2017-11-14

    A load power device includes a power input; at least one power output for at least one load; and a plurality of sensors structured to sense voltage and current at the at least one power output. A processor is structured to provide real-time execution of: (a) a plurality of load identification algorithms, and (b) event detection and operating mode detection for the at least one load.

  17. Unethical evidence against cattle dignity during loading ...

    African Journals Online (AJOL)

    Some activities that showed unethical practices against cattle during loading, transportation and off-loading were considered in this paper. Three major cattle market centres (Akinyele, Bodija and Oranyan) in Ibadan metropolis were used. Eighty (80) structured questionnaires were randomly administered to the cattle ...

  18. The risks of extreme load extrapolation

    NARCIS (Netherlands)

    Bos, R.; Bierbooms, W.A.A.M.

    2017-01-01

    An important problem in wind turbine design is the prediction of the 50-year load, as set by the IEC 61400-1 Design Load Case (DLC) 1.1. In most cases, designers work with limited simulation budgets and are forced to use extrapolation schemes to obtain the required return level. That this is no easy

  19. Direct Load Control by AC Frequency Modulation

    DEFF Research Database (Denmark)

    Douglass, Philip James; You, Shi

    2012-01-01

    Fine-grained under frequency load shedding called “demand as a frequency controlled reserve“ (DFCR) has been shown to be a promising method of providingfrequency regulation service from distributed loads [1]. Micro-grids with a large portion of intermittent renewable generation will benefit greatly...

  20. Plastic collapse load of corroded steel plates

    Indian Academy of Sciences (India)

    The main aim of present work is to study plastic collapse load of corroded steel plates with irregular surfaces under tension. Non-linear finite element method by using computer code ANSYS was employed to determine plastic collapse load. By comparing the results with uniform thickness assumption, a reduction factor was.

  1. Load-Bearing Capacity of Roof Trusses

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Damkilde, Lars; Munch-Andersen, J.

    2004-01-01

    systems such as roof trusses are established and statistical characteristics of the load bearing capacity are determined. The results show that there is a significant increase in the characteristic (nominal) value and a reduction in the coefficient of variation (COV) for typical loads such as permanent...

  2. A review of research in rotor loads

    Science.gov (United States)

    Bousman, William G.; Mantay, Wayne R.

    1988-01-01

    The research accomplished in the area of rotor loads over the last 13 to 14 years is reviewed. The start of the period examined is defined by the 1973 AGARD Milan conference and the 1974 hypothetical rotor comparison. The major emphasis of the review is research performed by the U.S. Army and NASA at their laboratories and/or by the industry under government contract. For the purpose of this review, two main topics are addressed: rotor loads prediction and means of rotor loads reduction. A limited discussion of research in gust loads and maneuver loads is included. In the area of rotor loads predictions, the major problem areas are reviewed including dynamic stall, wake induced flows, blade tip effects, fuselage induced effects, blade structural modeling, hub impedance, and solution methods. It is concluded that the capability to predict rotor loads has not significantly improved in this time frame. Future progress will require more extensive correlation of measurements and predictions to better understand the causes of the problems, and a recognition that differences between theory and measurement have multiple sources, yet must be treated as a whole. There is a need for high-quality data to support future research in rotor loads, but the resulting data base must not be seen as an end in itself. It will be useful only if it is integrated into firm long-range plans for the use of the data.

  3. Accommodating oversize and overweight loads : technical report.

    Science.gov (United States)

    2012-07-01

    Adequate management of oversize/overweight (OS/OW) permit loads throughout the state of Texas is : critical to maintaining a vibrant state economy. The growth in the number and size of permit loads in recent : years is clear evidence that new tools a...

  4. Fruit load governs transpiration of olive trees

    NARCIS (Netherlands)

    Bustan, Amnon; Dag, Arnon; Yermiyahu, Uri; Erel, Ran; Presnov, Eugene; Agam, Nurit; Kool, Dilia; Iwema, Joost; Zipori, Isaac; Ben-Gal, Alon

    2016-01-01

    We tested the hypothesis that whole-tree water consumption of olives (Olea europaea L.) is fruit load-dependent and investigated the driving physiological mechanisms. Fruit load was manipulated in mature olives grown in weighing-drainage lysimeters. Fruit was thinned or entirely removed from

  5. Duration of load effects of solid wood

    DEFF Research Database (Denmark)

    Svensson, Staffan

    Test methods for studying the effect of long-term loading on the load carrying capacity of structural wood are discussed. The impact of sampling procedures on test results is investigated and is exemplified. It is concluded from this investigation that the sampling method has a significant impact...

  6. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  7. Baseline axle load survey in Malawi - 2014

    CSIR Research Space (South Africa)

    Roux, M

    2015-07-01

    Full Text Available As part of the project to update the Malawian Directorate of Road Transport and Safety Services’ (DRTSS) 2005 Axle Load Control Strategy and to provide a five-year implementation plan, a country-wide axle load survey was undertaken to assess...

  8. Controllable Load Management Approaches in Smart Grids

    Directory of Open Access Journals (Sweden)

    Jingshuang Shen

    2015-10-01

    Full Text Available With rapid smart grid technology development, the customer can actively participate in demand-side management (DSM with the mutual information communication between the distributor operation company and the smart devices in real-time. Controllable load management not only has the advantage of peak shaving, load balance, frequency regulation, and voltage stability, but is also effective at providing fast balancing services to the renewable energy grid in the distributed power system. The load management faces an enormous challenge as the customer has a large number of both small residential loads and dispersed renewable sources. In this paper, various controllable load management approaches are discussed. The traditional controllable load approaches such as the end users’ controllable appliances, storage battery, Vehicle-to-Grid (V2G, and heat storage are reviewed. The “broad controllable loads” management, such as the microgrid, Virtual Power Plant (VPP, and the load aggregator are also presented. Furthermore, the load characteristics, control strategies, and control effectiveness are analyzed.

  9. Monitoring Athlete Training Loads: Consensus Statement.

    Science.gov (United States)

    Bourdon, Pitre C; Cardinale, Marco; Murray, Andrew; Gastin, Paul; Kellmann, Michael; Varley, Matthew C; Gabbett, Tim J; Coutts, Aaron J; Burgess, Darren J; Gregson, Warren; Cable, N Timothy

    2017-04-01

    Monitoring the load placed on athletes in both training and competition has become a very hot topic in sport science. Both scientists and coaches routinely monitor training loads using multidisciplinary approaches, and the pursuit of the best methodologies to capture and interpret data has produced an exponential increase in empirical and applied research. Indeed, the field has developed with such speed in recent years that it has given rise to industries aimed at developing new and novel paradigms to allow us to precisely quantify the internal and external loads placed on athletes and to help protect them from injury and ill health. In February 2016, a conference on "Monitoring Athlete Training Loads-The Hows and the Whys" was convened in Doha, Qatar, which brought together experts from around the world to share their applied research and contemporary practices in this rapidly growing field and also to investigate where it may branch to in the future. This consensus statement brings together the key findings and recommendations from this conference in a shared conceptual framework for use by coaches, sport-science and -medicine staff, and other related professionals who have an interest in monitoring athlete training loads and serves to provide an outline on what athlete-load monitoring is and how it is being applied in research and practice, why load monitoring is important and what the underlying rationale and prospective goals of monitoring are, and where athlete-load monitoring is heading in the future.

  10. Traffic load effects in prestrssed concrete bridges

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.; Allaix, D.L.; Courage, W.M.G.

    2007-01-01

    The traffic load effect of a two-span prestressed concrete bridge with two traffic lanes is analyzed in this paper. The design value of the result-ing bending moment in some prescribed sections is estimated by means of a Monte Carlo simulation. The model for the vehicular loads is derived from a set

  11. Foot Marching, Load Carriage, and Injury Risk

    Science.gov (United States)

    2016-05-01

    2014. The Impact of Occupational Load Carriage on Carrier Mobility : A Critical Review of the Literature. JOSE, Vol. 20, No. 1, 3–11. 11. Orr, R.M...Performance Division, USARIEM, Natick, Ma 01760-50073, May 2000. 17. Haisman, M. F. 1988. Determinants Of Load Carrying Ability. Applied Ergonomics

  12. Modeling of Generic Slung Load System

    DEFF Research Database (Denmark)

    Bisgaard, Morten; Bendtsen, Jan Dimon; la Cour-Harbo, Anders

    2009-01-01

    ' Principle of Least Constraint using the Udwadia-Kalaba equation and can be used to model all body to body slung load suspension types. The model provides intuitive and easy-to-use means of modelling and simulating different slung load suspension types. It includes detection of, and response to, wire...... of the model is illustrated through simulations and flight verifications.  ...

  13. Plutonium Immobilization Can Loading Equipment Review

    International Nuclear Information System (INIS)

    Kriikku, E.; Ward, C.; Stokes, M.; Randall, B.; Steed, J.; Jones, R.; Hamilton, L.

    1998-05-01

    This report lists the operations required to complete the Can Loading steps on the Pu Immobilization Plant Flow Sheets and evaluates the equipment options to complete each operation. This report recommends the most appropriate equipment to support Plutonium Immobilization Can Loading operations

  14. Synthetic jet actuation for load control

    NARCIS (Netherlands)

    de Vries, Hein; van der Weide, Edwin Theodorus Antonius; Hoeijmakers, Hendrik Willem Marie

    2014-01-01

    The reduction of wind turbine blade loads is an important issue in the reduction of the costs of energy production. Reduction of the loads of a non-cyclic nature requires so-called smart rotor control, which involves the application of distributed actuators and sensors to provide fast and local

  15. Critical loads of heavy metals for soils

    NARCIS (Netherlands)

    Vries, de W.; Groenenberg, J.E.; Lofts, S.; Tipping, E.; Posch, M.

    2012-01-01

    To enable a precautionary risk assessment for future inputs of metals, steady-state methods have been developed to assess critical loads of metals avoiding long-term risks to food quality and eco-toxicological effects on organisms in soils and surface waters. A critical load for metals equals the

  16. Design concept of the HPLWR moderator flow path

    International Nuclear Information System (INIS)

    Koehly, Christina; Schulenberg, Thomas; Starflinger, Joerg

    2009-01-01

    The latest design concept of the High Performance Light Water Reactor (HPLWR) includes a thermal core in which supercritical water at 25 MPa inlet pressure is heated up from 280degC reactor inlet temperature to 500degC core exit temperature in three steps with intermediate coolant mixing to minimize peak cladding temperatures of the fuel rods. Prior to entering the first fuel assemblies, the coolant is used as moderator in water rods inside assemblies, in the gap volume between assembly boxes, as well as in the surrounding axial or radial reflectors. Even though assembly boxes and moderator rods are designed with a certain thermal insulation, heat is generated in the moderator water or transferred to it from the superheated steam inside assemblies, causing concern of natural convection phenomena with uncontrolled neutronic feedback on the core power distribution. Moreover, bypass flows of the moderator water need to be minimized at any thermal expansion of the reactor internal structures to avoid an unpredictable moderator mass flow. The design concept of the moderator flow path described in this paper is trying to overcome these problems. Downward flow of moderator water is limited to sub-cooled conditions, well below the pseudo-critical point of supercritical water. Dedicated orifices are foreseen to allow later correction of the mass flow split. The sealing concept accounts for larger thermal expansions of reactor components by using C-rings or bellows. A welded construction is preferred wherever possible to minimize leakage. The removable steam plenum is aligned at the extractable steam pipes to minimize thermal displacements at the sealing positions. The paper is showing several design details to illustrate the technical solutions. (author)

  17. Individuals underestimate moderate and vigorous intensity physical activity.

    Directory of Open Access Journals (Sweden)

    Karissa L Canning

    Full Text Available BACKGROUND: It is unclear whether the common physical activity (PA intensity descriptors used in PA guidelines worldwide align with the associated percent heart rate maximum method used for prescribing relative PA intensities consistently between sexes, ethnicities, age categories and across body mass index (BMI classifications. OBJECTIVES: The objectives of this study were to determine whether individuals properly select light, moderate and vigorous intensity PA using the intensity descriptions in PA guidelines and determine if there are differences in estimation across sex, ethnicity, age and BMI classifications. METHODS: 129 adults were instructed to walk/jog at a "light," "moderate" and "vigorous effort" in a randomized order. The PA intensities were categorized as being below, at or above the following %HRmax ranges of: 50-63% for light, 64-76% for moderate and 77-93% for vigorous effort. RESULTS: On average, people correctly estimated light effort as 51.5±8.3%HRmax but underestimated moderate effort as 58.7±10.7%HRmax and vigorous effort as 69.9±11.9%HRmax. Participants walked at a light intensity (57.4±10.5%HRmax when asked to walk at a pace that provided health benefits, wherein 52% of participants walked at a light effort pace, 19% walked at a moderate effort and 5% walked at a vigorous effort pace. These results did not differ by sex, ethnicity or BMI class. However, younger adults underestimated moderate and vigorous intensity more so than middle-aged adults (P<0.05. CONCLUSION: When the common PA guideline descriptors were aligned with the associated %HRmax ranges, the majority of participants underestimated the intensity of PA that is needed to obtain health benefits. Thus, new subjective descriptions for moderate and vigorous intensity may be warranted to aid individuals in correctly interpreting PA intensities.

  18. Application of gamma densitometer for measurement of void fraction in liquid hydrogen moderator of HANARO cold neutron source

    International Nuclear Information System (INIS)

    Kim, Myong-Seop; Choi, Jungwoon; Sun, Gwang-Min; Lee, Kye-Hong

    2009-01-01

    The void fraction in the liquid hydrogen used for the moderator of the HANARO cold neutron source (CNS) was measured by using a gamma densitometer technique. A mock-up of the HANARO CNS facility with an electric heating system as the heat source instead of radiations was constructed. The photon transmissions through the hydrogen moderator were simulated to search for an optimum experimental condition. From the simulation, it was confirmed that Am-241 was suitable for the measurement of the void fraction in the liquid hydrogen medium. A gamma densitometer using the Am-241 gamma-ray source was designed and installed at the mock-up of the CNS. The attenuation of 59.5 keV gamma-rays from the Am-241 through the hydrogen medium was measured by using an HPGe detector. The void fraction was determined using the amount of the gamma-ray attenuation. The void fractions in the hydrogen moderator were measured for stable thermo-siphon loops with several electric heat loads applied to the moderator cell of the CNS mock-up. The longitudinal distribution of the void fraction inside the moderator cell was also determined. The void fraction measured at a heat load of 720 W had values of 8-41% depending on the height from the bottom of the moderator cell. The overall void fraction was obtained by volume-weighted averaging of its longitudinal distribution. The void fraction at the nuclear heating power expected at the normal operation condition of the HANARO CNS facility was determined to be about 20%. The large uncertainty was expected in the void fraction determination by a gamma densitometer for the liquid hydrogen medium with the void fraction less than 10%. When the void fraction of the liquid hydrogen was near 20%, the uncertainty in the void fraction determination by using a gamma densitometer became relatively small, and it was regarded as an acceptable level. The measurements for the void fraction will be very useful for the design and operation of the HANARO CNS.

  19. Damage Accumulation in Vertical Breakwaters due to Combined Impact Loading and Pulsating Wave Loads

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Nielsen, Søren R. K.

    1999-01-01

    Vertical wall breakwaters used to protect for example an harbour from large waves usually consist of large concrete caissons placed on the seabed. The wave loads can be divided in two types, pulsating and impact loads. For some types of breakwaters especially the impact wave loads can be very large...

  20. 14 CFR 29.511 - Ground load: unsymmetrical loads on multiple-wheel units.

    Science.gov (United States)

    2010-01-01

    ... multiple-wheel units. 29.511 Section 29.511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Requirements Ground Loads § 29.511 Ground load: unsymmetrical loads on multiple-wheel units. (a) In dual-wheel gear units, 60 percent of the total ground reaction for the gear unit must be applied to one wheel and...

  1. A kinetic comparison of back-loading and head-loading in Xhosa women.

    Science.gov (United States)

    Lloyd, R; Parr, B; Davies, S; Cooke, C

    2011-04-01

    The purpose of this study was to compare the kinetic responses associated with ground reaction force measurements to both head-loading and back-loading in a group of Xhosa women. Altogether, 16 women were divided into two groups based on their experience of head-loading. They walked over a force plate in three conditions: unloaded or carrying 20 kg in either a backpack or on their head. The most striking finding was that there was no difference in kinetic response to head-loading as a consequence of previous experience. Considering the differences between the load carriage methods, most changes were consistent with increasing load. Head-loading was, however, associated with a shorter contact time, smaller thrust maximum and greater vertical force minimum than back-loading. Both loading conditions differed from unloaded walking for a number of temporal variables associated with the ground contact phase, e.g. vertical impact peak was delayed whilst vertical thrust maximum occurred earlier. STATEMENT OF RELEVANCE: Consideration of the kinetics of head and back load carriage in African women is important from a health and safety perspective, providing an understanding of the mechanical adaptations associated with both forms of load carriage for a group of people for whom such load carriage is a daily necessity.

  2. Handball load and shoulder injury rate

    DEFF Research Database (Denmark)

    Møller, M.; Nielsen, R.O.; Attermann, J.

    2017-01-01

    Background Knowledge of injury patterns, an essential step towards injury prevention, is lacking in youth handball. Aim To investigate if an increase in handball load is associated with increased shoulder injury rates compared with a minor increase or decrease, and if an association is influenced...... by scapular control, isometric shoulder strength or glenohumeral range of motion (ROM). Methods 679 players (14-18 years) provided weekly reports on shoulder injury and handball load (training and competition hours) over 31 weeks using the SMS, phone and medical examination system. Handball load in a given...... was performed at baseline and midseason. Results An increase in handball load by >60% was associated with greater shoulder injury rate (HR 1.91; 95% CI 1.00 to 3.70, p=0.05) compared with the reference group. The effect of an increase in handball load between 20% and 60% was exacerbated among players...

  3. Simulation of Stochastic Loads for Fatigue Experiments

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Brincker, Rune

    1989-01-01

    A simple direct simulation method for stochastic fatigue-load generation is described in this paper. The simulation method is based on the assumption that only the peaks of the load process significantly affect the fatigue life. The method requires the conditional distribution functions of load...... ranges given the last peak values. Analytical estimates of these distribution functions are presented in the paper and compared with estimates based on a more accurate simulation method. In the more accurate simulation method samples at equidistant times are generated by approximating the stochastic load...... process by a Markov process. Two different spectra from two tubular joints in an offshore structure (one narrow banded and one wide banded) are considered in an example. The results show that the simple direct method is quite efficient and results in a simulation speed of about 3000 load cycles per second...

  4. Simulation of Stochastic Loads for Fatigue Experiments

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Brincker, Rune

    1989-01-01

    process by a Markov process. Two different spectra from two tubular joints in an offshore structure (one narrow banded and one wide banded) are considered in an example. The results show that the simple direct method is quite efficient and results in a simulation speed of about 3000 load cycles per second......A simple direct simulation method for stochastic fatigue-load generation is described in this paper. The simulation method is based on the assumption that only the peaks of the load process significantly affect the fatigue life. The method requires the conditional distribution functions of load...... ranges given the last peak values. Analytical estimates of these distribution functions are presented in the paper and compared with estimates based on a more accurate simulation method. In the more accurate simulation method samples at equidistant times are generated by approximating the stochastic load...

  5. Simulation of Stochastic Loads for Fatigue Experiments

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Brincker, Rune

    process by a Markov process. Two different spectra from two tubular joints in an offshore structure (one narrow banded and one wide banded) are considered in an example. The results show that the simple direct method is quite efficient and is results in a simulation speed at about 3000 load cycles per......A simple direct simulation method for stochastic fatigue load generation is described in this paper. The simulation method is based on the assumption that only the peaks of the load process significantly affect the fatigue life. The method requires the conditional distribution functions of load...... ranges given the last peak values. Analytical estimates of these distribution functions are presented in the paper and compared with estimates based on a more accurate simulation method. In the more accurate simulation method samples at equidistant times are generated by approximating the stochastic load...

  6. A methodology for Electric Power Load Forecasting

    Directory of Open Access Journals (Sweden)

    Eisa Almeshaiei

    2011-06-01

    Full Text Available Electricity demand forecasting is a central and integral process for planning periodical operations and facility expansion in the electricity sector. Demand pattern is almost very complex due to the deregulation of energy markets. Therefore, finding an appropriate forecasting model for a specific electricity network is not an easy task. Although many forecasting methods were developed, none can be generalized for all demand patterns. Therefore, this paper presents a pragmatic methodology that can be used as a guide to construct Electric Power Load Forecasting models. This methodology is mainly based on decomposition and segmentation of the load time series. Several statistical analyses are involved to study the load features and forecasting precision such as moving average and probability plots of load noise. Real daily load data from Kuwaiti electric network are used as a case study. Some results are reported to guide forecasting future needs of this network.

  7. High power s-band vacuum load

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Michael [Muons, Inc., Batavia, IL (United States); Dudas, Alan [Muons, Inc., Batavia, IL (United States); Krasnykh, Anatoly [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-29

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  8. Quantifying Training Loads in Contemporary Dance.

    Science.gov (United States)

    Jeffries, Annie C; Wallace, Lee; Coutts, Aaron J

    2017-07-01

    To describe the training demands of contemporary dance and determine the validity of using the session rating of perceived exertion (sRPE) to monitor exercise intensity and training load in this activity. In addition, the authors examined the contribution of training (ie, accelerometry and heart rate) and non-training-related factors (ie, sleep and wellness) to perceived exertion during dance training. Training load and ActiGraphy for 16 elite amateur contemporary dancers were collected during a 49-d period, using heart-rate monitors, accelerometry, and sRPE. Within-individual correlation analysis was used to determine relationships between sRPE and several other measures of training intensity and load. Stepwise multiple regressions were used to determine a predictive equation to estimate sRPE during dance training. Average weekly training load was 4283 ± 2442 arbitrary units (AU), monotony 2.13 ± 0.92 AU, strain 10677 ± 9438 AU, and average weekly vector magnitude load 1809,707 ± 1015,402 AU. There were large to very large within-individual correlations between training-load sRPE and various other internal and external measures of intensity and load. The stepwise multiple-regression analysis also revealed that 49.7% of the adjusted variance in training-load sRPE was explained by peak heart rate, metabolic equivalents, soreness, motivation, and sleep quality (y = -4.637 + 13.817%HR peak + 0.316 METS + 0.100 soreness + 0.116 motivation - 0.204 sleep quality). The current findings demonstrate the validity of the sRPE method for quantifying training load in dance, that dancers undertake very high training loads, and a combination of training and nontraining factors contribute to perceived exertion in dance training.

  9. Impact of anticholinergic load of medications on the length of stay of cancer patients in hospice care.

    Science.gov (United States)

    Gupte, Komal P; Wu, Wenchen

    2015-06-01

    An important goal of hospice care is to relieve pain and suffering of terminal cancer patients. Anticholinergic medications are effective in the symptom palliation among terminal cancer patients. However, use of these medications has been associated with increased risk of side effects, which might lead to premature mortality. Short lengths of stay in hospice care leave patients with a higher level of unmet needs. The study was conducted to examine the effect of increasing anticholinergic load on the length of stay of cancer patients in hospice care in the USA. The National Home and Hospice Care Survey 2007 was used as the data source. The Cox proportional hazards model was used to investigate the risk of death among users of moderate and high anticholinergic load compared with users of low anticholinergic load in presence of other prognostic factors. Cancer patients on a moderate anticholinergic load had a 12.7% lower hazard of death (P = 0.0244), while those on a high anticholinergic load had a 15.6% lower hazard of death (P = 0.0071) as compared with those patients on a low anticholinergic load. Among other prognostic factors, non-elderly age group, male gender, white race, metropolitan hospice agency, non-profit hospice agency, severe activities of daily living dependency and cognitive impairment were significantly associated with a higher probability of death. These results provide no evidence for increasing anticholinergic load increasing mortality in cancer patients using hospice care. Thus, high anticholinergic load might have conferred a protective effect on the patients because of better symptom control. © 2014 Royal Pharmaceutical Society.

  10. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    International Nuclear Information System (INIS)

    Cowlam, S.; Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I.; Yiannakou, Y.J.

    2008-01-01

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically

  11. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    Energy Technology Data Exchange (ETDEWEB)

    Cowlam, S. [Sunderland Royal Hospital, Sunderland (United Kingdom); Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I. [University Hospital of North Durham, Durham (United Kingdom); Yiannakou, Y.J. [University Hospital of North Durham, Durham (United Kingdom)], E-mail: yan.yiannakou@cddft.nhs.uk

    2008-12-15

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically.

  12. Moderate hyperopia prevalence and associated factors among elementary school students

    Directory of Open Access Journals (Sweden)

    Victor Delpizzo Castagno

    2015-05-01

    Full Text Available Hyperopia is the most common refractive condition in childhood. There are few studies on moderate hyperopia and associated factors. This study aims to investigate the prevalence of moderate hyperopia and associated factors among school children. A cross-sectional study comprising 1,032 students attending 1st to 8th grades at two public schools was conducted in a Southern Brazilian urban area in 2012. Cycloplegia was used to examine both eyes and refractive error was measured through auto-refraction. A socioeconomic and cultural questionnaire was administered. Multivariable analysis was performed through Poisson regression. Moderate hyperopia prevalence was 13.4% (95% CI, 11.2-15.4 and 85% of these did not wear glasses. Age was inversely associated with moderate hyperopia, while female gender RP = 1.39 (95%CI, 1.02 - 1.90 and white skin RP = 1.66 (95%CI, 1.04 - 2.66 were risk factors for this outcome. This study makes progress in estimating mild and moderate hyperopia prevalence both by age range and specific age. It emphasizes how the lack of this condition being corrected in southern Brazil is a serious problem. It highlights the importance of detailing and characterizing the amount of time spent on close-range, long-range and outdoor activities.

  13. Effects of working memory load and repeated scenario exposure on emergency braking performance.

    Science.gov (United States)

    Engström, Johan; Aust, Mikael Ljung; Viström, Matias

    2010-10-01

    The objective of the present study was to examine the effect of working memory load on drivers' responses to a suddenly braking lead vehicle and whether this effect (if any) is moderated by repeated scenario exposure. Several experimental studies have found delayed braking responses to lead vehicle braking events during concurrent performance of nonvisual, working memory-loading tasks, such as hands-free phone conversation. However, the common use of repeated, and hence somewhat expected, braking events may undermine the generalizability of these results to naturalistic, unexpected, emergency braking scenarios. A critical lead vehicle braking scenario was implemented in a fixed-based simulator.The effects of working memory load and repeated scenario exposure on braking performance were examined. Brake response time was decomposed into accelerator pedal release time and accelerator-to-brake pedal movement time. Accelerator pedal release times were strongly reduced with repeated scenario exposure and were delayed by working memory load with a small but significant amount (178 ms).The two factors did not interact. There were no effects on accelerator-to-brake pedal movement time. The results suggest that effects of working memory load on response performance obtained from repeated critical lead vehicle braking scenarios may be validly generalized to real world unexpected events. The results have important implications for the interpretation of braking performance in experimental settings, in particular in the context of safety-related evaluation of in-vehicle information and communication technologies.

  14. In vivo hip joint loads and pedal forces during ergometer cycling.

    Science.gov (United States)

    Damm, P; Dymke, J; Bender, A; Duda, G; Bergmann, G

    2017-07-26

    The rising prevalence of osteoarthritis and an increase in total hip replacements calls for attention to potential therapeutic activities. Cycling is considered as a low impact exercise for the hip joint and hence recommended. However, there are limited data about hip joint loading to support this claim. The aim of this study was to measure synchronously the in vivo hip joint loads and pedal forces during cycling. The in vivo hip joint loads were measured in 5 patients with instrumented hip implants. Data were collected at several combinations of power and cadence, at two saddle heights. Joint loads and pedal forces showed strong linear correlation with power. So the relationship between the external pedal forces and internal joint forces was shown. While cycling at different cadences the minimum joint loads were acquired at 60RPM. The lower saddle height configuration results in an approximately 15% increase compared to normal saddle height. The results offered new insights into the actual effects of cycling on the hip joint and can serve as useful tools while developing an optimum cycling regimen for individuals with coxarthrosis or following total hip arthroplasty. Due to the relatively low contact forces, cycling at a moderate power level of 90W at a normal saddle height is suitable for patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Visual Assessment of Surface Fuel Loads Does Not Align with Destructively Sampled Surface Fuels

    Directory of Open Access Journals (Sweden)

    Sarah C. McColl-Gausden

    2017-10-01

    Full Text Available Fuel load and structure are fundamental drivers of fire behaviour. Accurate data is required for managers and researchers to better understand our ability to alter fire risk. While there are many ways to quantify fuel, visual assessment methods are generally considered the most efficient. Visual hazard assessments are commonly used by managers, government agencies and consultants to provide a fuel hazard score or rating but not a quantity of fuel. Many systems attempt to convert the hazard score or rating to a fuel load for use in fire behaviour models. Here we investigate whether the conversion table in the widely used Overall Fuel Hazard Guide (OFHG matches destructively sampled fuel loads from 116 sites across five forest types. We specifically examine whether there are quantifiable differences that can be attributed to forest type. We found there is overlap between the two methods for low, moderate and high hazard categories, however for the very high and extreme hazard categories, visual assessment overestimated fuel load in four of the five forest types. Using a commonly applied fire behaviour model, we found that the overestimation of fuel load in very high and extreme hazard categories leads to an overestimation of fire behavior in these hazard categories.

  16. USING BENCH PRESS LOAD TO PREDICT UPPER BODY EXERCISE LOADS IN PHYSICALLY ACTIVE INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    Del P. Wong

    2013-03-01

    Full Text Available This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m-2 were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p < 0.01. The bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p < 0.01. Linear regression revealed that the bench press load was a significant (R2 range from 0.64 to 0.86, p < 0.01 predictor for the loads of the 4 assistance exercises. The following 6RM prediction equations were determined: (a Hammer curl = Bench press load (0.28 + 6.30 kg, (b Barbell biceps curl = Bench press load (0.33 + 6.20 kg, (c Overhead triceps extension = Bench press load (0.33 - 0.60 kg, and (d Dumbbell shoulder press = Bench press load (0.42 + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises.

  17. Someone to count on: social support as an effect modifier of viral load suppression in a prospective cohort study.

    Science.gov (United States)

    Friedman, M Reuel; Coulter, Robert W S; Silvestre, Anthony J; Stall, Ron; Teplin, Linda; Shoptaw, Steve; Surkan, Pamela J; Plankey, Michael W

    2017-04-01

    Though functional social support has been shown to serve as a protective factor for HIV viral load suppression in other populations, scant research has examined this relationship among men who have sex with men (MSM) in the United States. We assessed characteristics of social support, effects of social support on HIV viral load, and moderation by social support of the relationship between psychosocial indicators of a synergistic epidemic (syndemic) and HIV viral load. We analyzed longitudinal data from HIV-positive MSM using antiretroviral therapy who were enrolled in the Multicenter AIDS Cohort Study between 2002 and 2009 (n = 712). First, we conducted reliability assessments of a one-item social support measure. Then, we conducted a series of generalized longitudinal mixed models to assess our research questions. Moderation was assessed using an interaction term. A three-level (low/medium/high) social support variable demonstrated high reliability (intraclass correlation coefficients  = 0.72; 95% CI: 0.70, 0.75). Black and Hispanic MSM reported lower social support than their White counterparts (p social support (p social support (p social support levels were associated with greater viral load suppression and lower viral load means (p Social support moderated the relationships between syndemic and HIV viral load (p HIV-positive MSM, particularly those of color, may benefit greatly from interventions that can successfully boost functional social support. Creating strengths-based interventions may also have particularly high impact among HIV-positive MSM with the highest psychosocial burdens.

  18. The high moderating ratio reactor using 100% MOX reloads

    International Nuclear Information System (INIS)

    Barbrault, P.

    1994-06-01

    This report presents the concept of a High Moderating ratio Reactor, which should accept 100% MOX reloads. This reactor aims to be the plutonium version of the European Pressurized Reactor (EPR), which is developed jointly by French and German companies. A moderating ration of 2.5 (instead of the standard value of 2.0) is obtained by replacing several fuel rods by water holes. The core would contain 241 Fuel Assemblies. We present some advantages of over-moderation for plutonium fuel, a description of the core and assemblies, calculations of fuel reload schemes and Reactivity Shutdown Margins, and the behavior of the core during two occidental transients. (author). 2 refs., 9 figs., 2 tabs

  19. Moderators of Response to Telephone Continuing Care for Alcoholism

    Science.gov (United States)

    Lynch, Kevin G.; Van Horn, Deborah; Drapkin, Michelle; Ivey, Megan; Coviello, Donna; McKay, James R.

    2011-01-01

    Objectives To evaluate potential moderators of the effect of adding extended telephone monitoring (TM) and telephone monitoring and counseling (TMC) continuing care to treatment as usual (TAU) for alcoholism. Continuing care was predicted to be more effective for patients with severe substance-use histories, poor initial response to treatment, and other risk factors for relapse. Methods Randomized study with 18-month follow-up. Outcomes were frequency of drinking and any drinking. Results Main effects favored TMC over TAU on alcohol outcomes. However, none of the 11 variables examined moderated these effects. Conversely, main effect and moderator analyses indicated TM was more beneficial than TAU only for women and for participants with lower readiness to change. Conclusions TMC improves drinking outcomes when added to standard care, regardless of alcohol use history, early response to treatment, or other risk factors for relapse. TM is recommended for women and less motivated patients. PMID:20604702

  20. Moderation of antidepressant response by the serotonin transporter gene

    DEFF Research Database (Denmark)

    Huezo-Diaz, Patricia; Uher, Rudolf; Smith, Rebecca

    2009-01-01

    Background: There have been conflicting reports on whether the length polymorphism in the promoter of the serotonin transporter gene (5-HTTLPR) moderates the antidepressant effects of selective serotonin reuptake inhibitors (SSRIs). We hypothesised that the pharmacogenetic effect of 5-HTTLPR...... is modulated by gender, age and other variants in the serotonin transporter gene. Aims: To test the hypothesis that the 5-HTTLPR differently influences response to escitalopram (an SSRI) compared with nortriptyline (a noradrenaline reuptake inhibitor). Method: The 5-HTTLPR and 13 additional markers across...... the serotonin transporter gene were genotyped in 795 adults with moderate-to-severe depression treated with escitalopram or nortriptyline in the Genome Based Therapeutic Drugs for Depression (GENDEP) project. Results: The 5-HTTLPR moderated the response to escitalopram, with long-allele carriers improving more...

  1. Moderators of the Relationship between Implicit and Explicit Evaluation

    Science.gov (United States)

    Nosek, Brian A.

    2005-01-01

    Automatic and controlled modes of evaluation sometimes provide conflicting reports of the quality of social objects. This paper presents evidence for four moderators of the relationship between automatic (implicit) and controlled (explicit) evaluations. Implicit and explicit preferences were measured for a variety of object pairs using a large sample. The average correlation was r = .36, and 52 of the 57 object pairs showed a significant positive correlation. Results of multilevel modeling analyses suggested that: (a) implicit and explicit preferences are related, (b) the relationship varies as a function of the objects assessed, and (c) at least four variables moderate the relationship – self-presentation, evaluative strength, dimensionality, and distinctiveness. The variables moderated implicit-explicit correspondence across individuals and accounted for much of the observed variation across content domains. The resulting model of the relationship between automatic and controlled evaluative processes is grounded in personal experience with the targets of evaluation. PMID:16316292

  2. Moderator veranderlikes en differensiele geldigheid van die aansoekvorm

    Directory of Open Access Journals (Sweden)

    A. de Bod

    1977-11-01

    Empiriese studies toon dat die Geweegde Aansoekvorm (G.A.V. 'n doeltreffende voorspellingsinstrument in personeelseleksie is. Daar is egter studies wat voorspel dat die voorspellingsgeldigheid van die G.A.V. in die literatuur aansienlik oorbeklemtoon word. Teenstrydig met die beginsels van klassieke psigometriese teorie word voorgestel dat moderator veranderlikes vir hierdie paradoks verantwoordelik is. Hierdie studie toon hoe die biografiese korrelate van dienstyd as moderators fungeer en empiriese bewys van die modererende effek op die voorspellingsgeldigheid van die G.A.V. word gelewer. Daar word voorgestel dat ‘n nuwe benadering tot die ontwikkeling van die G.A.V. noodsaaklik is ten einde die effek van moderators te benut.

  3. The ideology of moderated modernism in Serbian music and musicology

    Directory of Open Access Journals (Sweden)

    Medić Ivana

    2007-01-01

    Full Text Available The term ′moderated modernism′ has been current for quite some time in Serbian music historiography, but there have been only a few attempts to define it. I shall try to define the term, introduce some of its key concepts and features and demonstrate its applicability. Although moderated modernism was an international phenomenon which had divergent manifestations in various periods before and after the Second World War throughout Europe, my aim is to focus on the period between the decline of Socialist Realism and the ascent of post-modernism (roughly 1950 to 1980 in socialist Serbia, and to discuss the discourses and ideologies surrounding moderated modernism then and there.

  4. Is Familiarity a Moderator of Brand/Country Alliances?

    DEFF Research Database (Denmark)

    Kristensen, Tore; Gabrielsen, Gorm; Jaffe, Eugene D.

    2014-01-01

    Product and brand familiarity have an important role in consumer choice behaviour and they have been equated with knowledge and experience Consumers having high and low familiarity utilized brand information (an extrinsic cue) in their evaluations, whereas moderately familiar consumers used...... intrinsic cues (product attributes) in evaluating products. The question of whether familiarity moderates the country-of-origin (COO) effect is a valid one. In this present paper, we attempt to provide additional evidence as to how familiarity with products, brands and countries moderates consumer...... evaluation of brand/country alliances. Specifically, we concentrate on the brand leveraging process identified by Keller (2003) applied to the effect of familiarity on country/brand alliances....

  5. Submarine ground-water discharge: nutrient loading and nitrogen transformations

    Science.gov (United States)

    Kroeger, Kevin D.; Swarzenski, Peter W.; Crusius, John; Bratton, John F.; Charette, Matthew A.

    2006-01-01

    Eutrophication of coastal waters due to nonpoint source land-derived nitrogen (N) loads is a worldwide phenomenon and perhaps the greatest agent of change altering coastal ecology (National Research Council, 2000; Howarth and others, 2000). Within the United States, a majority of estuaries have been determined to be moderately to severely impaired by eutrophication associated with increasing nutrient loads (Bricker and others, 1999).In coastal watersheds with soils of high hydraulic conductivity and permeable coastal sediments, ground water is a major route of transport of freshwater and its solutes from land to sea. Freshwater flowing downgradient from aquifers may either discharge from a seepage face near the intertidal zone, or flow directly into the sea as submarine ground-water discharge (SGD) (fig. 1). In the coastal aquifer, entrainment of saline pore water occurs prior to discharge, producing a gradient in ground-water salinity from land to sea, referred to as a subterranean estuary (Moore, 1999). In addition, processes including density-driven flow and tidal pumping create brackish and saline ground-water circulation. Hence, submarine ground-water discharge often consists of a substantial amount of recirculating seawater. Mixing of fresh and saline ground waters in the context of coastal sediments may alter the chemical composition of the discharging fluid. Depending on the biogeochemical setting, removal of fixed N due to processes leading to N2 (dinitrogen gas) production in the nearshore aquifer and subterranean estuary may significantly attenuate land-derived N loads; or, processes such as ion exchange and tidal pumping in the subterranean estuary may substantially accelerate the transport of both land-derived and sediment re-mineralized N to estuarine water columns.As emphasized by Burnett and others (2001, 2002), a fundamental problem in evaluating the importance of ground-water discharge in marine geochemical budgets is the difficulty of collecting

  6. Effect of ripple loads on sustained-load cracking in titanium alloys

    International Nuclear Information System (INIS)

    Pao, P.S.; Meyn, D.A.; Bayles, R.A.; Feng, C.R.; Yoder, G.R.

    1995-01-01

    In the present paper, the authors have extended their study on the effect of the ripple loads on the sustained-load cracking (SLC) behavior of two titanium alloys, Ti-6Al-4V (an α-β alloy) and Ti-15V-3Cr-3Al-3Sn (a β-α alloy), in an ambient air environment. The methodology which has been used successfully to treat ripple effects on stress-corrosion cracking (SCC) is employed again to address the influence of ripple loads on sustained-load cracking. Ripple loads can significantly reduce the apparent sustained load cracking resistance of titanium alloys in a relatively benign environment such as ambient air. For a ripple-load amplitude equal to 5% of the sustained load, the ripple-load cracking thresholds (K IRLC ) of beta-annealed Ti-6Al-4V and Ti-15V-3Cr-3al-3Sn are less than half of the respective sustained-load cracking thresholds (K ISLC ). The extent of ripple-load degradation for these alloys in ambient air -- relative to K ISLC , were found comparable to those observed in a much more aggressive 3.5% NaCl aqueous solution

  7. Probabilistic model of bridge vehicle loads in port area based on in-situ load testing

    Science.gov (United States)

    Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong

    2017-11-01

    Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.

  8. Evaluation of Limit Loads for Circumferentially Cracked Pipes Under Combined Loadings

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Ho-Wan; Han, Jae-Jun; Kim, Yun-Jae [Korea University, Seoul (Korea, Republic of)

    2015-05-15

    Since the Fukushima nuclear accident, several researchers are extensively studying the effect of torsion on the piping systems In nuclear power plants. Piping installations in power plants with a circumferential crack can be operated under combined loading conditions such as bending and torsion. ASME Code provides flaw evaluations for fully plastic fractures using limit load criteria for the structural integrity of the cracked pipes. According to the recent version of Code, combined loadings are provided only for the membrane and bending. Even though actual operating conditions have torsion loading, the methodology for evaluating torsion load is not established. This paper provides the results of limit load analyses by using finite element models for circumferentially cracked pipes under pure bending, pure torsion, and combined bending and torsion with tension. Theoretical limit load solutions based on net-section fully plastic criteria are suggested and verified with the results of finite element analyses.

  9. Evaluation of Limit Loads for Circumferentially Cracked Pipes Under Combined Loadings

    International Nuclear Information System (INIS)

    Ryu, Ho-Wan; Han, Jae-Jun; Kim, Yun-Jae

    2015-01-01

    Since the Fukushima nuclear accident, several researchers are extensively studying the effect of torsion on the piping systems In nuclear power plants. Piping installations in power plants with a circumferential crack can be operated under combined loading conditions such as bending and torsion. ASME Code provides flaw evaluations for fully plastic fractures using limit load criteria for the structural integrity of the cracked pipes. According to the recent version of Code, combined loadings are provided only for the membrane and bending. Even though actual operating conditions have torsion loading, the methodology for evaluating torsion load is not established. This paper provides the results of limit load analyses by using finite element models for circumferentially cracked pipes under pure bending, pure torsion, and combined bending and torsion with tension. Theoretical limit load solutions based on net-section fully plastic criteria are suggested and verified with the results of finite element analyses

  10. Hood River Conservation Project load analysis

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.

    1987-11-01

    As a part of the Hood River Conservation Project (HRCP), 314 homes were monitored to measure electrical energy use. The total electrical load, space heating load, water heating load (in about 200 homes), wood-stove heat output (in about 100 homes), and indoor temperature were monitored. Data were collected for one full year before and one full year after these homes were retrofit with conservation measures. Local weather information was also collected on a 15-min basis. This data base was used to evaluate the load savings attributable to HRCP. Two methods of weather normalization were used and showed close agreement. The weather-normalized diversified residential load savings on the Pacific Power and Light system and Hood River area peak days were >0.5 kW/household. The average spring, summer, and fall savings were much smaller, <0.1 kW/household. The load factor for the diversified residential load decreased following the conservation retrofit actions. 11 refs., 40 figs., 13 tabs.

  11. Electricity Crisis and Load Management in Bangladesh

    Directory of Open Access Journals (Sweden)

    Rajib Kanti Das

    2012-09-01

    Full Text Available Bangladesh is a densely populated country. Only a small part of her area is electrified which cover around 18% of total population. The people who are in the electrified area are suffering from severe load shedding. A systematic load management procedure related to demand side may improve the situation is the research problem. The major objectives serve by the research are to analyze contemporary electricity status with a view to drawing inference about demand supply gap and extracting benefits from load management. Data supplied by the Bangladesh Power Development Board, World Bank and outcome of survey are analyzed with some simple statistical tools to test the hypothesis. Analysis discloses that with properly managed uses of electricity with load switch and rotation week-end can improve the concurrent condition of electricity. Moreover, introducing smart distribution system, reducing system loss, shifting load to off-peak, large scale use of prepaid mete, observing energy week and using energy efficient home and office appliance are recommended to improve load through demand side management. Some other recommendations such as introducing alternative energy, public private partnership and using renewable energy development and producing energy locally are made for load management from the supply side.

  12. The load structure of electro boilers

    International Nuclear Information System (INIS)

    Feilberg, N.; Livik, K.

    1995-01-01

    Load measurements have been performed on 24 electro boilers with a time resolution of one hour throughout a period of one year. The boilers are used for space heating and heating of tap water in office buildings, shopping centres and apartment buildings. All boilers have tariffs with disconnection agreements. This report presents load analyses of the measurements from each boiler, and typical load profiles are calculated and presented. It also analyses how boilers are used in relation to the outdoor temperature and the power price on the spot market. All the measurements are performed in Bergen, Norway, in the period August 1993 - August 1994. Typical load profiles are shown, both annual and daily, as well as specific load parameters in addition to key figures used in calculating the total power load on the distribution network. The climate impact on energy and power load is evaluated. The report also shows examples of how the results may be applied in various special fields. 8 figs., 9 tabs

  13. Running with a load increases leg stiffness.

    Science.gov (United States)

    Silder, Amy; Besier, Thor; Delp, Scott L

    2015-04-13

    Spring-mass models have been used to characterize running mechanics and leg stiffness in a variety of conditions, yet it remains unknown how running while carrying a load affects running mechanics and leg stiffness. The purpose of this study was to test the hypothesis that running with a load increases leg stiffness. Twenty-seven subjects ran at a constant speed on a force-measuring treadmill while carrying no load, and while wearing weight vests loaded with 10%, 20%, and 30% of body weight. We measured lower extremity motion and created a scaled musculoskeletal model of each subject, which we used to estimate lower extremity joint angles and leg length. We estimated dimensionless leg stiffness as the ratio of the peak vertical ground reaction force (normalized to body weight) and the change in stance phase leg length (normalized to leg length at initial foot contact). Leg length was calculated as the distance from the center of the pelvis to the center-of-pressure under the foot. We found that dimensionless leg stiffness increased when running with load (p=0.001); this resulted from an increase in the peak vertical ground reaction force (pleg length (p=0.025). When running with load, subjects had longer ground contact times (pleg stiffness to accommodate an added load. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Stresses in pin-loaded tubes

    Science.gov (United States)

    Ahmad, Ishtiaq

    This thesis deals with a parametric 3-dimensional photoelastic study of the stresses in pin-loaded tubes, commonly used in securing an aircraft engine into the air frame. Among the geometric variables studied (normalised with reference to the outer tube diameter) are included form values of the ratio of pin-hole diameter to outer tube diameter (0.10, 0.20, 0.40 and 0.60), four different hole-centre positions relative to the tube end and six values of the ratio of tube thickness to outer tube diameter (0.04, 0.08, 0.16, 0.25, 0.32 and 0.50). The other variables investigated are clearance between pin and hole, pin stiffness and lubrication. Some combinations of pairs of pins, either parallel or "crossed" have also been studied, and the effects of different modes of tensile loading, compressive loading, bending loading and torsional loading have been assessed. The results include details of the distribution of normalised changes in tube diameter along the planes of symmetry, the distribution of stress indices around the tube ends, the distribution of stress indices along planes of symmetry and the distribution of stress indices around the pin-loaded holes. The work is discussed in detail. The results provide a valuable reference in the design of pin-loaded tubes.

  15. Work load and musculoskeletal complaints during pregnancy.

    Science.gov (United States)

    Paul, J A; van Dijk, F J; Frings-Dresen, M H

    1994-06-01

    Many pregnant women have musculoskeletal complaints, the onset and aggravation of which are thought to be associated with their activity or work postures. The purpose of this paper was to obtain more insight into the influence of pregnancy on the load of the musculoskeletal system at work to provide a better basis for preventing complaints. To this end, literature pertinent to a model called "work load of the musculoskeletal system" was reviewed. The model was developed to describe how work contributes to musculoskeletal complaints. It was found that pregnancy causes changes in a worker's characteristics. These changes can lead to changes in the work situation, activity pattern, and postural characteristics and possibly result in a change in work load. In addition, physical changes such as weight gain increase the work load in a given posture. The load-bearing capacity of the musculoskeletal system decreases due to pregnancy. The changes in load and the decrease in load-bearing capacity singly or simultaneously increase the risk of musculoskeletal complaints. The multifactorial cause of musculoskeletal complaints during pregnancy reveals various possibilities for prevention.

  16. Neutron spectra produced by moderating an isotopic neutron source

    International Nuclear Information System (INIS)

    Carrillo Nunnez, Aureliano; Vega Carrillo, Hector Rene

    2001-01-01

    A Monte Carlo study has been carried out to determine the neutron spectra produced by an isotopic neutron source inserted in moderating media. Most devices used for radiation protection have a response strongly dependent on neutron energy. ISO recommends several neutron sources and monoenergetic neutron radiations, but actual working situations have broad spectral neutron distributions extending from thermal to MeV energies, for instance, near nuclear power plants, medical applications accelerators and cosmic neutrons. To improve the evaluation of the dosimetric quantities, is recommended to calibrate the radiation protection devices in neutron spectra which are nearly like those met in practice. In order to complete the range of neutron calibrating sources, it seems useful to develop several wide spectral distributions representative of typical spectra down to thermal energies. The aim of this investigation was to use an isotopic neutron source in different moderating media to reproduce some of the neutron fields found in practice. MCNP code has been used during calculations, in these a 239PuBe neutron source was inserted in H2O, D2O and polyethylene moderators. Moderators were modeled as spheres and cylinders of different sizes. In the case of cylindrical geometry the anisotropy of resulting neutron spectra was calculated from 0 to 2 . From neutron spectra dosimetric features were calculated. MCNP calculations were validated by measuring the neutron spectra of a 239PuBe neutron source inserted in a H2O cylindrical moderator. The measurements were carried out with a multisphere neutron spectrometer with a 6LiI(Eu) scintillator. From the measurements the neutron spectrum was unfolded using the BUNKIUT code and the UTA4 response matrix. Some of the moderators with the source produce a neutron spectrum close to spectra found in actual applications, then can be used during the calibration of radiation protection devices

  17. Effect of resistive load on the inspiratory work and power of breathing during exertion.

    Directory of Open Access Journals (Sweden)

    Thomas Powell

    Full Text Available The resistive work of breathing against an external load during inspiration (WR(I was measured at the mouth, during sub-maximal exercise in healthy participants. This measure (which excludes the elastic work component allows the relationship between resistive work and power, ventilation and exercise modality to be explored. A total of 45 adult participants with healthy lung function took part in a series of exercise protocols, in which the relationship between WR(I, power of breathing, PR(I and minute ventilation, [Formula: see text] were assessed during rest, while treadmill walking or ergometer cycling, over a range of exercise intensities (up to 150 Watts and ventilation rates (up to 48 L min(-1 with applied constant resistive loads of 0.75 and 1.5 kPa.L.sec(-1. Resting WR(I was 0.12 JL(-1 and PR(I was 0.9 W. At each resistive load, independent of the breathing pattern or exercise mode, the WR(I increased in a linear fashion at 20 mJ per litre of [Formula: see text], while PR(I increased exponentially. With increasing resistive load the work and power at any given [Formula: see text] increased exponentially. Calculation of the power to work ratio during loaded breathing suggests that loads above 1.5 kPa.L.sec(-1 make the work of resistive breathing become inhibitive at even a moderate [Formula: see text] (>30 L sec(-1. The relationship between work done and power generated while breathing against resistive loads is independent of the exercise mode (cycling or walking and that ventilation is limited by the work required to breathe, rather than an inability to maintain or generate power.

  18. I can see clearly now: The effects of age and perceptual load on inattentional blindness

    Directory of Open Access Journals (Sweden)

    Anna eRemington

    2014-04-01

    Full Text Available Attention and awareness are known to be linked (e.g. see Lavie, Beck, & Konstantinou, 2014, for a review. However the extent to which this link changes over development is not fully understood. Most research concerning the development of attention has investigated the effects of attention on distraction, visual search and spatial orienting, typically using reaction time measures which cannot directly support conclusions about conscious awareness. Here we used Lavie’s Load Theory of Attention and Cognitive Control to examine the development of attention effects on awareness. According to Load Theory awareness levels are determined by the availability of attentional capacity. We hypothesised that attentional capacity develops with age, and consequently that awareness rates should increase with development due to the enhanced capacity. Thus we predicted that greater rates of inattentional blindness (IB would be found at a younger age, and that lower levels of perceptual load will be sufficient to exhaust capacity and cause IB in children but not adults. We tested this hypothesis using an IB paradigm with adults and children aged 7-8, 9-10, 11-12 and 13 years old. Participants performed a line-length judgment task (indicating which arm of a cross is longer and on the last trial were asked to report whether they noticed an unexpected task-irrelevant stimulus (a small square in the display. Perceptual load was varied by changing the line-length difference (with a smaller difference in the conditions of higher load. The results supported our hypothesis: levels of awareness increased with age, and a moderate increase in the perceptual load of the task led to greater IB for children but not adults. These results extended across both peripheral and central presentations of the task stimuli. Overall, these findings establish the development of capacity for awareness and demonstrate the critical role of the perceptual load in the attended task.

  19. Standardized loads acting in knee implants.

    Directory of Open Access Journals (Sweden)

    Georg Bergmann

    Full Text Available The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint. The implants were powered inductively and the loads transmitted at radio frequency. The time courses of forces and moments during walking, stair climbing, and 6 more activities were averaged for subjects with I average body weight and average load levels and II high body weight and high load levels. During all investigated activities except jogging, the high force levels reached 3,372-4,218N. During slow jogging, they were up to 5,165N. The peak torque around the implant stem during walking was 10.5 Nm, which was higher than during all other activities including jogging. The transverse forces and the moments varied greatly between the subjects, especially during non-cyclic activities. The high load levels measured were mostly above those defined in the wear test ISO 14243. The loads defined in the ISO test standard should be adapted to the levels reported here. The new data will allow realistic investigations and improvements of joint replacement, surgical procedures for tendon repair, treatment of fractures, and others. Computer models of the load conditions in the lower extremities will become more realistic if the new data is used as a gold standard. However, due to the extreme individual variations of some load components, even the reported average load profiles can most likely not explain every failure of an implant or a surgical procedure.

  20. Factor structure underlying components of allostatic load.

    Directory of Open Access Journals (Sweden)

    Jeanne M McCaffery

    Full Text Available Allostatic load is a commonly used metric of health risk based on the hypothesis that recurrent exposure to environmental demands (e.g., stress engenders a progressive dysregulation of multiple physiological systems. Prominent indicators of response to environmental challenges, such as stress-related hormones, sympatho-vagal balance, or inflammatory cytokines, comprise primary allostatic mediators. Secondary mediators reflect ensuing biological alterations that accumulate over time and confer risk for clinical disease but overlap substantially with a second metric of health risk, the metabolic syndrome. Whether allostatic load mediators covary and thus warrant treatment as a unitary construct remains to be established and, in particular, the relation of allostatic load parameters to the metabolic syndrome requires elucidation. Here, we employ confirmatory factor analysis to test: 1 whether a single common factor underlies variation in physiological systems associated with allostatic load; and 2 whether allostatic load parameters continue to load on a single common factor if a second factor representing the metabolic syndrome is also modeled. Participants were 645 adults from Allegheny County, PA (30-54 years old, 82% non-Hispanic white, 52% female who were free of confounding medications. Model fitting supported a single, second-order factor underlying variance in the allostatic load components available in this study (metabolic, inflammatory and vagal measures. Further, this common factor reflecting covariation among allostatic load components persisted when a latent factor representing metabolic syndrome facets was conjointly modeled. Overall, this study provides novel evidence that the modeled allostatic load components do share common variance as hypothesized. Moreover, the common variance suggests the existence of statistical coherence above and beyond that attributable to the metabolic syndrome.

  1. Automation techniques applied to systematic studies of moderator coupling

    International Nuclear Information System (INIS)

    Ansell, S.; Garcia, J.F.; Bennington, S.M.; Picton, D.J.; Broome, T.

    2004-01-01

    We present new computation methods in which the geometry management of MCNPX input files can be automated. We demonstrate this method with respect to the target station 2 design at ISIS. The method presented is not a mathematically robust method, but by starting from a valid baseline model allows this model to be mutated in a reliable way. Those features that still need to be improved and added are discussed at the end. We use this method to show that a mixed lead/water pre-moderator gives a better neutron flux to radiation damage ratio for the coupled moderator. (orig.)

  2. Moderate Deviation Principles for Stochastic Differential Equations with Jumps

    Science.gov (United States)

    2014-01-15

    bounded and continuous functions respectively. For Banach spaces B1; B2, L(B1; B2) will denote the space of bounded linear operators from B1 to B2. For...random vectors in a Banach space . Chinese J. Appl. Probab. Statist., 7(1):24�32, 1991. [14] X. Chen. Moderate deviations form-dependent random...variables with Banach space values. Statist. Probab. Lett., 35(2):123�134, 1997. ISSN 0167-7152. [15] X. Chen. Moderate deviations for Markovian occupation

  3. [Effect of moderate alcohol consumption on insulin sensitivity].

    Science.gov (United States)

    Abel, Tatjána; Fehér, János

    2009-12-06

    Moderate alcohol consumption has been reported to be associated with lower risk for both cardiovascular disease and type 2 diabetes. An explanation for these epidemiologic observations is not entirely clear. Alcohol raises high-density lipoprotein (HDL) cholesterol levels. Other potential beneficial mechanisms have been proposed including anti-inflammatory and anti-thrombotic effects. The association between moderate alcohol consumption and insulin sensitivity is still under debate. Possible mechanisms include elevation of adiponectin level, reduction of C-reactive protein and suppression of free fatty acid release from adipose tissue.

  4. Adalimumab for the treatment of moderate to severe hidradenitis suppurativa

    DEFF Research Database (Denmark)

    Kimball, A.B.; Kerdel, F.; Adams, D.

    2012-01-01

    with moderate to severe HS. Design: Phase 2, parallel, randomized, placebo-controlled trial consisting of a blinded 16-week period (period 1) and an open-label 36-week period (period 2). All study personnel, investigators, and patients remained blinded to treatment group throughout the study. (Clinical......Trials.gov: NCT00918255) Setting: 26 academic and private practice medical centers in the United States and Europe. Patients: 154 adult patients with moderate to severe HS who were unresponsive or intolerant to oral antibiotics. Intervention: Patients were assigned in a 1:1:1 ratio to adalimumab, 40 mg...

  5. A combined loading system integrated with portable winch and polyethylene chutes for loading of timber products

    Directory of Open Access Journals (Sweden)

    H. Hulusi Acar

    2016-01-01

    Full Text Available Truck loading operation is an important task during timber production operations in forestry. In Turkey, approximately 50 million timbers/logs are being produced per year, and then they are loaded into the logging trucks. The timber/logs are transported over the forest roads with an average of one million roundtrips. However, the traditional loading methods using manpower are mostly performed while some part is done by using loading machines which can be very costly and risky. This study aims developing a combined loading system in which heavy logs are loaded into logging trucks by pulling them by a log-line powered by a portable crane within the chute system. The slope of the log-line from ground to logging truck varied between 1% and 25%. Within the each work cycle of loading operation, only one log was loaded by pulling with portable crane. The average loading time was found as 161.8 seconds per cycle, in which 67% of the time was spent on pulling the log into the logging truck. The results indicated that the average pulling speed with crane power was 840.4 m/hr and productivity was calculated as 4.94 m3/hr. The result on system speed and productivity indicated close relations with results from previous studies. The hydraulic grapple loader or cranes are widely used and common loading machines, but they cannot be efficiently used in forestry operations, especially ones having a low timber productivity rate or having low economic value timber. In these conditions, loading methods that are cost efficient and do not require higher production rate should be employed. Therefore, a combined loading system introduced in this study can be a feasible solution for loading operations in those cases. Furthermore, it is believed that this loading system integrated with a portable crane can be cost efficient and time saving solution, as well as ergonomic and safe method in the field.

  6. Wind turbine blade testing under combined loading

    DEFF Research Database (Denmark)

    Roczek-Sieradzan, Agnieszka; Nielsen, Magda; Branner, Kim

    2011-01-01

    The paper presents full-scale blade tests under a combined flap- and edgewise loading. The main aim of this paper is to present the results from testing a wind turbine blade under such conditions and to study the structural behavior of the blade subjected to combined loading. A loading method using...... anchor plates was applied, allowing transverse shear distortion. The global and local deformation of the blade as well as the reproducibility of the test was studied and the results from the investigations are presented....

  7. Modelling and Simulation of Wave Loads

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    1985-01-01

    A simple model of the wave load on stender members of offshore structures is described . The wave elevation of the sea stateis modelled by a stationary Gaussian process. A new procedure to simulate realizations of the wave loads is developed. The simulation method assumes that the wave particle...... velocity can be approximated by a Gaussian Markov process. Known approximate results for the first passage density or equivalently, the distribution of the extremes of wave loads are presented and compared with rather precise simulation results. It is demonstrated that the approximate results...

  8. Modelling and Simulation of Wave Loads

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    velocity can be approximated by a Gaussian Markov process. Known approximate results for the first-passage density or equivalently, the distribution of the extremes of wave loads are presented and compared with rather precise simulation results. It is demonstrated that the approximate results......A simple model of the wave load on slender members of offshore structures is described. The wave elevation of the sea state is modelled by a stationary Gaussian process. A new procedure to simulate realizations of the wave loads is developed. The simulation method assumes that the wave particle...

  9. Modelling and Simulation of Wave Loads

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    1985-01-01

    velocity can be approximated by a Gaussian Markov process. Known approximate results for the first passage density or equivalently, the distribution of the extremes of wave loads are presented and compared with rather precise simulation results. It is demonstrated that the approximate results......A simple model of the wave load on stender members of offshore structures is described . The wave elevation of the sea stateis modelled by a stationary Gaussian process. A new procedure to simulate realizations of the wave loads is developed. The simulation method assumes that the wave particle...

  10. Numerical Analyses of Plate Loading Test

    Directory of Open Access Journals (Sweden)

    Ionuţ-Ovidiu Toma

    2009-01-01

    Full Text Available A numerical simulation of plate loading test, in order to underlines the size effect on settlements and derived values of geotechnical parameters, is shown. The study is based on the comparison between the results obtained by Finite Element Method (FEM using the Mohr-Coulomb soil model and by some observations from literature. The obtained numerical results revealed that the subgrade reaction coefficient is strictly dependent on parameters like size of the loaded area and loading magnitude, and thus completely general and generic, and not a fundamental material property of soil that can somehow be determined rationally, as often one claims to be.

  11. Electric power distribution and load transfer system

    Science.gov (United States)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1989-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  12. Load flow optimization and optimal power flow

    CERN Document Server

    Das, J C

    2017-01-01

    This book discusses the major aspects of load flow, optimization, optimal load flow, and culminates in modern heuristic optimization techniques and evolutionary programming. In the deregulated environment, the economic provision of electrical power to consumers requires knowledge of maintaining a certain power quality and load flow. Many case studies and practical examples are included to emphasize real-world applications. The problems at the end of each chapter can be solved by hand calculations without having to use computer software. The appendices are devoted to calculations of line and cable constants, and solutions to the problems are included throughout the book.

  13. Case for domestic electrical load management

    Energy Technology Data Exchange (ETDEWEB)

    Giddens, E.P.

    1986-07-01

    At the present time electricity generation and distribution systems have sufficient capacity to cope with maximum peak loads that occur infrequently and only for short periods. The average load factor is significantly below unity. As the demand for power inevitably increases, the capacities of the supply and distribution systems simultaneously have to be enlarged to maintain this margin of excess capacity. A case is presented for use of existing technology to facilitate a gradual transition to a more cost effective basis for electricity consumption and supply. The basis of the proposed method lies in domestic load management. A research team of architects and engineers is suggested.

  14. Strength of concrete structures under dynamic loading

    Science.gov (United States)

    Kumpyak, O. G.; Galyautdinov, Z. R.; Kokorin, D. N.

    2016-01-01

    The use of elastic supports is one the efficient methods of decreasing the dynamic loading. The paper describes the influence of elastic supports on the stress-strain state of steel concrete structures exposed to one-time dynamic loading resulting in failure. Oblique bending beams on elastic supports and their elastic, elastoplastic, and elastoplastic consolidation behavior are considered in this paper. For numerical calculations the developed computer program is used based on the finite element method. Research findings prove high efficiency of elastic supports under dynamic loading conditions. The most effective behavior of elastic supports is demonstrated at the elastoplastic stage. A good agreement is observed between the theoretical and experimental results.

  15. Compressive Load Resistance Characteristics of Rice Grain

    OpenAIRE

    Sumpun Chaitep; Chaiy R. Metha Pathawee; Pipatpong Watanawanyoo

    2008-01-01

    Investigation was made to observe the compressive load property of rice gain both rough rice and brown grain. Six rice varieties (indica and japonica) were examined with the moisture content at 10-12%. A compressive load with reference to a principal axis normal to the thickness of the grain were conducted at selected inclined angles of 0°, 15°, 30°, 45°, 60° and 70°. The result showed the compressive load resistance of rice grain based on its characteristic of yield s...

  16. Design Load Basis for Offshore Wind turbines

    DEFF Research Database (Denmark)

    Natarajan, Anand; Hansen, Morten Hartvig; Wang, Shaofeng

    2016-01-01

    DTU Wind Energy is not designing and manufacturing wind turbines and does therefore not need a Design Load Basis (DLB) that is accepted by a certification body. However, to assess the load consequences of innovative features and devices added to existing offshore turbine concepts or new offshore...... turbine concept developed in our research, it is useful to have a full DLB that follows the current design standard and is representative of a general DLB used by the industry. It will set a standard for the offshore wind turbine design load evaluations performed at DTU Wind Energy, which is aligned...

  17. The roles of sensory function and cognitive load in age differences in inhibition: Evidence from the Stroop task.

    Science.gov (United States)

    Peng, Huamao; Gao, Yue; Mao, Xiaofei

    2017-02-01

    To explore the roles of visual function and cognitive load in aging of inhibition, the present study adopted a 2 (visual perceptual stress: noise, nonnoise) × 2 (cognitive load: low, high) × 2 (age: young, old) mixed design. The Stroop task was adopted to measure inhibition. The task presentation was masked with Gaussian noise according to the visual function of each individual in order to match visual perceptual stress between age groups. The results indicated that age differences in the Stroop effect were influenced by visual function and cognitive load. When the cognitive load was low, older adults exhibited a larger Stroop effect than did younger adults in the nonnoise condition, and this age difference disappeared when the visual noise of the 2 age groups was matched. Conversely, in the high cognitive load condition, we observed significant age differences in the Stroop effect in both the nonnoise and noise conditions. The additional cognitive load made the age differences in the Stroop task reappear even when visual perceptual stress was equivalent. These results demonstrate that visual function plays an important role in the aging of inhibition and its role is moderated by cognitive load. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. 14 CFR 23.337 - Limit maneuvering load factors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factors. 23.337... Flight Loads § 23.337 Limit maneuvering load factors. (a) The positive limit maneuvering load factor n... airplanes; or (3) 6.0 for acrobatic category airplanes. (b) The negative limit maneuvering load factor may...

  19. 40 CFR 92.106 - Equipment for loading the engine.

    Science.gov (United States)

    2010-07-01

    ...: electrical resistance load bank; fans or other means for cooling of the load bank; wattmeter, including phase angle compensation; meter(s) for measurement of the current through the load bank (a calibrated... the load bank; and electrical cable to connect the alternator/generator to the load bank. Many...

  20. Development of a Novel Loading Device for Studying Magnesium Degradation under Compressive Load for Implant Applications.

    Science.gov (United States)

    Tian, Qiaomu; Antonio Mendez, Jose; Rivera-Castaneda, Laura; Mahmood, Omar; Showalter, Adam; Ang, Elizabeth; Kazmi, Sarah; Liu, Huinan

    2018-04-15

    Medical implants play a key role in treating bone fractures. Permanent implants are currently used for immobilization of fractures and bearing physiological loads during bone healing. After bone has healed, these implants, if not removed, often cause complications in the long run; and secondary surgeries for removing them pose additional discomfort and expenses for patients. Magnesium (Mg)-based bioresorbable implants, can potentially eliminate the need for additional surgeries by degrading safely over time in the human body. When studying the degradation behaviors of Mg-based implants in vitro , it is important to simulate physiological conditions in vivo closely, including loading. Considering that implants often carry physiological loads in vivo and mechanical stresses affect the degradation rate of Mg, a novel loading device was designed and manufactured for studying Mg degradation under load over a long period of time in a simulated body fluid in vitro . Degradation of Mg rods were investigated by immersing in a revised simulated body fluid (rSBF) for two weeks while a consistent compressive load was applied using the loading device. The results showed that the loading device provided a consistent load of 500 ± 45 N during the two weeks of immersion. Mg rods showed a significant faster degradation rate under the applied load, as demonstrated by a higher mass loss of the sample, a higher pH increase and Mg 2+ ion release in the rSBF.